Loading...
HomeMy WebLinkAboutSOLR-21-0962 • City of Arcadia, CA Permit NO. SOLR-21-0962 i Development Services Department Permit Type:Solar 240 West Huntington Drive,Post Office Box 60021 Work Classification:Solar-Residential Arcadia,CA 91066-6021 (626)574-5416 Permit Status:Issued ARCADIA Issue Date:06/07/2021 Expiration: 06/07/2022 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number —85 W LEMON AVE Arcadia,CA 91007-8028 5782021018 Contacts Pedro Cotto Owner SUNPOWER CORPORATION SYSTEMS* Contractor 85 Lemon 1414 Harbour WAY#1901,Richmond,CA (408)218-6811 890895 Description: ROOF MOUNTED SOLAR ON DETACHED Valuation: $0.00 Tenant STRUCTURE 22 MODULES, 125 A LOADCENTER, 150A MCB Total Sq Feet: 0.00 Plan Check# Plan# , Fees Amount Payments Amount Paid Building Plan Check Fee Residential $100.00 Total Fees $324.72 Distribution Panel $16.48 Cash/Receipt#REC-07808-21 $324.72 Electrical Permit Issuance Fee $47.01 Amount Due: $0.00 Inverters $77.78 • Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $324.72 , CALLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. COMPLEED This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days —a-Z-7 from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. June 07, 2021 Issued By: Henry Kemick Date June 07,2021 Page 1 of 1 4 iliqm PERMIT/PLAN REVIEW APPLICATION 44I ' o Development Services Department, 240 West Huntington Drive, Post Office Box 60021 \Y/ Arcadia, CA 91066-6021, (626) 574-5416, Fax (626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION 0 I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. 0 I have and will maintain a certificate of consent to self-insure for workers' License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Signature of Contractor OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section 0 I herebyaffirm under 3700 of the Labor Code,for the performance of the work for which this permit penalty of perjury that I am exempt from the Contractors is issued.My workers'compensation insurance carrier and policy numbers are: License Law for the following reason(Section 7031.5,Business and Professions Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors License law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the forthwith comply with those provisions. property, or my employees with wages as their sole compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). 0 I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. Name Title PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature Date ` ''Au11 MIu: 'r 004a1t7 0��0 AFFIDAVIT SELF-CERTIFICATION FOR COMPLIANCE OF SMOKE ALARMS AND CARBON MONOXIDE ALARMS Property Address: «, c,e_ / 7 Permit Number> / — C) Q' .-- Brief Job Description: � y .IL / - Number of smoke alarms installed: Number of carbon monoxide alarms installed: When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created, Smoke alarms shall be installed in each sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2016 California Residential Code (CRC) and California Health and Safety Code Section 13113.7. For dwellings or sleeping units containing fuel burning appliances or having attached garages, carbon monoxide alarms shall be installed outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements as required by Section R315 of the of the 2016 California Residential Code (CRC). Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used. All alarms shall comply with requirements for listing and approval by the Office of the State Fire Marshal. http://osfm.fire.ca.qov/licensinglistings/Iicenselisting bml searchcotest.php As owner of the above referenced property, I hereby certify that the smoke alarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance with the code sections referenced above. t declare under penalty of perjury that the •r=goi ! is true and correct, and that this declaration was executed on (Date) ,i, . ' .4 at Arcadia, California. Owner's Name (printed/typed): r -. :e 02- -vim Signature of Owner:This affidavit must be returned to the City of Arcadia inspector prior to final inspection WV119VI0 HDNV218 , 56p 06BI 35 H3J11 YJ 30V)QVd 11Wa3d 1Vf101A10NI 11V1OS z 0S10 0'5£Ot5) it C 'd t ?. M in r OPNN r6 VD LOOT6VIN80d1110.V1CVD1JV w .lfIOS AV11110811YN tr.; gl zNPisAs •Nour11oa11oJ 3f1N3AVNOW311S3M S8 i' I Clo 1121 3 M C d N fl S W31SAS OIV11OAO1ONd 0311-O189MM 20'6 Y — 0110D VS32l31 F i a l a w ... ,, a f Q N Q Z _i - - a w > 6 J xx . §a 5' k Q V F z VI 5 1-4-4 CO ti N M t 1.0 kO It11.,• illtii Mitt Mtn Mgr M112 ^• :i:i iii MM g I .£££i£ji'i 11�- iAlii f.io:::1..::5......i£ii£i .. ..:Iii 'iiia u:N.UM::::::::::::: £££££Sul i'.CC:!!i!i!iii::030 gun ` —_ Hof:1 4i le WERTM SUNP 5/18/2021 Attn.: To Whom It May Concern re: Job TERESA COTTO: 85 WEST LEMON AVENUE, ARCADIA, CALIFORNIA 91007 The following calculations are for the structural engineering design of the photovoltaic panels. After review, I certify that the roof structure has sufficient structural capacity for the applied PV loads. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. If you have any questions, don't hesitate to contact. Q�oFESS/0,y p,. Heinrich Digitallyst� Heinrich Villanigne. NO. 80828 = m Villanueva Date:2021.05. EXP. 3-31-23 16:50:22-07'00 NOW- ,;91 - Design Criteria: Code: 2019 California Building Code ASCE 7-16 Live Load: 20 psf Ult Wind Speed: 110 mph Exposure Cat: C Ground Snow: 0 psf I 2125 E Katella Ave#220, Anaheim, CA 92806 1714.787.3850 I Date :5/18/2021 Job Code:TERESA COTTO SUN P O W E R"' 2of8 Structrure Geometry: Mean Roof Height, hn = 13 ft Eave Height, he = 8 ft Buiding Length, L = 124 ft Building Width, B = 54 ft Module Area = 17.5 ft2 Roof Properties: Roof 1 Roof 2 Roof 3 Roof Pitch (deg) = 23 23 23 Roofing Type= Comp Shingle Comp Shingle Comp Shingle Sheathing Type= 5/8 OSB Sheathing 5/8 OSB Sheathing 5/8 OSB Sheathing Wood Species= Doug Fir-Larch#2 Doug Fir-Larch#2 Doug Fir-Larch#2 Wood Fb(psf) = 129600 129600 129600 Wood Fv (psf)= 25920 25920 25920 Wood E (psf)= 230400000 230400000 230400000 Wood Lag Withdrawal (Ib/in) = 266 266 266 Framing Type= 2x4 Rafter 2x4 Rafter 2x6 Rafter Framing OC Spacing(in.) = 24 24 24 Section Thickness, b(in.)= 1.50 1.50 1.50 Section Depth,d (in.) = 3.50 3.50 5.50 Section Modulus,Sx(in.^3)= 3.06 3.06 7.56 Beam Span (ft)= 8 8 8 Pen Trib Width (ft) = 2.55 2.55 2.55 Rail Span (ft) = 4.00 4.00 4.00 CD(Wind)= 1.6 1.6 1.6 CD(Snow) = 1.15 1.15 1.15 CB= 1.15 1.15 1.15 CM= 1.0 1.0 1.0 Cc= 1.0 1.0 1.0 CL= 1.0 1.0 1.0 CF= 1.5 1.5 1.3 Cfu= 1.0 1.0 1.0 Ci= 1.0 1.0 1.0 Cr= 1.15 1.15 1.15 Mallowable wind (lb-ft) = 729 729 1560 Mallowable snow(Ib-ft)= 524 524 1121 2125 E Katella Ave#220,Anaheim, CA 92806 1714.787.3850 Date :5/18/2021 Job Code:TERESA COTTO ' SUN POWER"' 3of8 Dead Load: Comp Shingle 3.0 5/8 OSB Sheathing 2.0 2x4 Rafter @ 24" OC 0.6 Misc(Insulation etc) 1.0 Total Roof 1 DL 6.6 psf Comp Shingle 3.0 5/8 OSB Sheathing 2.0 2x4 Rafter @ 24" OC 0.6 Misc(Insulation etc) 1.0 Total Roof 2 DL 6.6 psf Comp Shingle 3.0 5/8 OSB Sheathing 2.0 2x6 Rafter @ 24" OC 0.9 Misc(Insulation etc) 1.0 Total Roof 3 DL 6.9 psf PV DL 2.8 psf Roof 1 Roof 2 Roof 3 Roof_Dist_DL= 12 12 13 M_Roof_Dist_DL= 97 97 102 Def Roof Dist DL= 0.0109 0.0109 0.0030 PV_uni_Dist_DL= 5 5 5 M_PV_uni_Dist_DL= 41 41 41 Def_PV_uni_Dist_DL= 0.0046 0.0046 0.0012 Total_uni DL= 17 17 18 M_Total_uni_DL= 139 139 144 Def Total uni DL= 0.0155 0.0155 0.0041 Rail_Down_DL= 7 7 7 Rail_M_DL= 13 13 13 Pens_Down_DL= 26 26 26 Pens Side DL= 11 11 11 2125 E Katella Ave#220,Anaheim,CA 92806 1714.787.3850 a Date :5/18/2021 Job Code:TERESA COTTO SUN P0 WE RT�., 4of8 Wind Load: Ultimate Wind Speed = 110 mph Directionality Factor, kd = 0.85 Topographic Factor, kzt= 1 Velocity Pressure Exposure Factor, kz= 0.85 Ground Elevation Factor, ke= 1.00 Velocity Pressure, qz= 22.35 Array Edge Factor,yE= 1.5 Solar Equalization Factor,ya = 0.75 Roof 1 Roof 2 Roof 3 External Pressure Up, GCp_1= -1.50 -1.50 -1.50 External Pressure Up, GCp_2= -2.20 -2.20 -2.20 External Pressure Up,GCp_3= -2.30 -2.30 -2.30 External Pressure Down,GCp= 0.60 0.60 0.60 Design Pressure Up, p_1= -37.72 -37.72 -37.72 Design Pressure Up, p_2= -55.32 -55.32 -55.32 Design Pressure Up, p_3 = -57.83 -57.83 -57.83 Design Pressure Down, p= 16.00 16.00 16.00 uni_Dist_W_up= -75 -75 -75 M_uni_Dist_W_up= -603 -603 -603 Def_uni_Dist_W_up= -0.0676 -0.0676 -0.0174 uni_Dist_W_down = 32 32 32 M_uni Dist_W_down = 256 256 256 Def uni Dist Wdown = 0.0287 0.0287 0.0074 Module_Up_W1= -38 -38 -38 Module_Up_W2= -55 -55 -55 0 Module Down W= 16 16 16 Rail_Up_W1= -96 -96 -96 Rail_Up_W2 = -141 -141 -141 Rail_Down_W= 41 41 41 Rail_M_Up_W1= -193 -193 -193 Rail_M_Up_W2= -283 -283 -283 2125 E Katella Ave#220,Anaheim, CA 92806 1714.787.3850 Date :5/18/2021 Job Code:TERESA COTTO 5 of 8 • TM SUNPOWER Rail MDown W= 82 82 82 Pens_Up_W1= -385 -385 -385 Pens_Up_W2= -565 -565 -565 Pens Down W= 163 163 163 Module Check: Roof 1 Down = 16 psf < 125 psf OK Roof 1 Up zl = 23 psf < 62 psf OK Roof 1 Up z2 = 33 psf < 62 psf OK Roof 2 Down = 16 psf < 125 psf OK Roof 2 Up z1 = 23 psf < 62 psf OK Roof 2 Up z2 = 33 psf < 62 psf OK Roof 3 Down = 16 psf < 125 psf OK Roof 3 Up zi = 23 psf < 62 psf OK Roof 3 Up z2 = 33 psf < 62 psf OK Rail Check(LRFD): Roof 1 1 1.4D : 19 lb-ft < 548 lb-ft OK Roof 1 1.2D+ 1.6S+0.5W : 57 lb-ft < 548 lb-ft OK Roof 1 1.2D+0.5S+ 1.0W : 98 lb-ft < 548 lb-ft OK Roof 1 0.9D+ 1.0W(Up z1) : 181 lb-ft < 548 lb-ft OK Roof 1 0.9D+ 1.0W (Up z2) : 271 lb-ft < 548 lb-ft OK Roof 2 1.4D : 19 lb-ft < 548 lb-ft OK Roof 2 1.2D+ 1.6S+0.5W : 57 lb-ft < 548 lb-ft OK Roof 2 1.2D+0.55+ 1.0W : 98 lb-ft < 548 lb-ft OK Roof 2 0.9D+ 1.0W(Up z1) : 181 lb-ft < 548 lb-ft OK Roof 2 0.9D+ 1.0W (Up z2) : 271 lb-ft < 548 lb-ft OK Roof 3 1.4D : 19 lb-ft < 548 lb-ft OK Roof 3 1.2D+ 1.6S+0.5W : 57 lb-ft < 548 lb-ft OK Roof 3 1.2D+0.5S+ 1.0W : 98 lb-ft < 548 lb-ft OK Roof 3 0.9+ 1.0W (Up z1) : 181 lb-ft < 548 lb-ft OK Roof 3 0.9+ 1.0W (Up z2) : 271 lb-ft < 548 lb-ft OK 2125 E Katella Ave#220,Anaheim, CA 92806 1714.787.3850 Date :5/18/2021 Job Code:TERESA COTTO ' SUN P O W E RT" 6of8 Attachment Check(ASD): Roof 1 1.0D+0.6W : 125 lbs < 803 lbs OK Roof 1 1.0D+0.75*[1.05+0.6W] : 100 lbs < 803 lbs OK Roof 1 1.0D+ 1.0S : 26 lbs < 803 lbs OK Roof 1 0.6D+0.6W(Up z1) : 215 lbs < 803 lbs OK Roof 1 0.6D+0.6W(Up z2) : 323 lbs < 803 lbs OK Roof 2 1.0D+0.6W : 125 lbs < 803 lbs OK Roof 2 1.0D+0.75*[1.05+0.6W] : 100 lbs < 803 lbs OK Roof 2 1.0D+ 1.0S : 26 lbs < 803 lbs OK Roof 2 0.6D+0.6W(Up z1) : 215 lbs < 803 lbs OK Roof 2 0.6D+0.6W(Up z2) : 323 lbs < 803 lbs OK Roof 3 1.0D+0.6W : 125 lbs < 803 lbs OK Roof 3 1.0D+0.75*[1.05+0.6W] : 100 lbs < 803 lbs OK Roof 3 1.0D+ 1.0S : 26 lbs < 803 lbs OK Roof 3 0.6D+0.6W(Up z1) : 215 lbs < 803 lbs OK Roof 3 0.6D+0.6W(Up z2) : 323 lbs < 803 lbs OK Attachment Lateral Check(ASD): Roof 1 1.0D+ 1.05 : 11 lbs < 472 lbs OK Roof 2 1.0D+ 1.0S : 11 lbs < 472 lbs OK Roof 3 1.0D+ 1.OS : 11 lbs < 472 lbs OK Lag Screw Uplift Check(ASD): Lag Screw Withdraw)Value= 266 lbs 5/16 Dia. Lag Screw Penetration= 2.5 in Roof 1 0.6D+0.6W(Up zl) : 215 lbs < 665 lbs OK Roof 1 0.6D+0.6W(Up z2) : 323 lbs < 665 lbs OK Roof 2 0.6D+0.6W(Up z1) : 215 lbs < 665 lbs OK Roof 2 0.6D+0.6W (Up z2) : 323 lbs < 665 lbs OK Roof 3 0.6D+0.6W(Up z1) : 215 lbs < 665 lbs OK 2125 E Katella Ave#220,Anaheim,CA 92806 1714.787.3850 Date :5/18/2021 Job Code:TERESA COTTO . SUNPOWER'" 7of8 Roof 3 0.6D+0.6W(Up z2) : 323 lbs < 665 lbs OK Framing Check(ASD): Roof 1 uni 1.0D+0.6W : 292 lb-ft < 729 lb-ft OK Roof 1 uni 1.0D+0.75*[1.OS+0.6W] : 254 lb-ft < 729 lb-ft OK Roof 1 uni 1.0D+ 1.0S : 139 lb-ft < 524 lb-ft OK Roof 1 uni 0.60+0.6W(Up z1) : 279 lb-ft < 729 lb-ft OK Roof 2 uni 1.OD+0.6W : 292 lb-ft < 729 lb-ft OK Roof 2 uni 1.0D+0.75*[1.05+0.6W] : 254 lb-ft < 729 lb-ft OK Roof 2 uni 1.0D+ 1.0S : 139 lb-ft < 524 lb-ft OK Roof 2 uni 0.6D+0.6W(Up z1) : 279 lb-ft < 729 lb-ft OK Roof 3 uni 1.OD+0.6W : 297 Ib ft < 1560 Ib ft OK Roof 3 uni 1.OD+0.75*[1.0S+0.6W] : 259 Ib ft < 1560 Ib ft OK Roof 3 uni 1.0D+ 1.OS : 144Ibft < 1121Ibft OK Roof 3 uni 0.6D+0.6 W (Up zi) : 276 lb-ft < 1560 Ib ft OK Framing Deflection Check(Service Level): Roof 1 Roof 1 Roof 1 Roof 1 Roof 2 Roof 2 uni D+ L: 0.279 in. < 0.53 in. OK uni W Up : 0.341 in. < 0.40 in. OK uni W Down : 0.144 in. < 0.40 in. OK uni S : 0.000 in. < 0.40 in. OK uni D+ L: 0.279 in. < 0.53 in. OK uni W Up : 0.341 in. < 0.40 in. OK Roof 2 uni W Down : 0.144 in. < 0.40 in. OK Roof 2 uni S : 0.000 in. < 0.40 in. OK Roof 3 uniD+ L: 0.075 in. < 0.53 in. OK Roof 3 unin W Up : 0.088 in. < 0.40 in. OK Roof 3 uni W Down : 0.037 in. < 0.40 in. OK Roof 3 uni S : 0.000 in. < 0.40 in. OK Seismic Check: 2125 E Katella Ave#220,Anaheim,CA 92806 1714.787.3850 Date :5/18/2021 Job Code:TERESA COTTO SUN povvE RT'A 8of8 Stucco 10.0 psf 2x4 Studs @ 16" 2.0 psf Gypsum 3.0 psf Misc. (Insulation,etc.) 2.0 psf Total Wall DL= 17 psf Total Wall Area = 2848 ftA2 Total Wall W= 48416 lbs Existing Weight Total Roof DL= 7 psf Total Roof Area = 6696 ftA2 Total Roof W= 44204 lbs Existing Weight PV Panel W= 46 lbs Number of Panels= 22 Total PV W= 1001 lbs Additional Weight %increase=(Wexisting+Wadditional)/Wexisting = 1.08% OK The increase in weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural anlaysis standards and procedures. 2125 E Katella Ave#220,Anaheim,CA 92806 1714.787.3850