Loading...
HomeMy WebLinkAboutSOLR-21-0254 r .ti ' City of Arcadia, CA Permit NO. SOLR-21-0254 • Development Services Department Permit Type:Solar 240 West Huntington Drive,Post Office Box 60021 Work Classification:Solar-Residential Arcadia,CA 91066-6021 (626)574-5416 Permit Status:Issued ARCADIA Issue Date:02/18/20211 Expiration: 02/18/2022 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 822 S GOLDEN WEST AVE A Arcadia,CA 91007-6563 5783009096 Contacts DI WU Owner ORANGE COUNTY SOLAR CONTRACTING Contractor 822 GOLDEN WEST AVE A,ARCADIA,CA 91007 SERVICES INC 1023627 ti Description:ROOF MOUNT PV SYSTEM 21 MODULES/1 Valuation: $0.00 Tenant INVERTER Total Sq Feet: 0.00 Plan Check# Plan# Low Fees Amount Payments Amount Paid Building Plan Check Fee Residential $100.00 Total Fees $308.24 Electrical Permit Issuance Fee $47.01 Cash/Receipt#REC-06774-21 $308.24 Inverters $77.78 Amount Due: $0.00 Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $308.24 L � 1 CALLS FOR INSPECTIONS -h . r / - 104", Request for inspection by telephone at 626-574-5450. Leave a message IV lr 1 requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. February 18, 2021 Issued By: Henry Kemick Date February 18,2021 Page 1 of 1 •F • `,I,IFORy�� 4 : 1 PERMIT/PLAN REVIEW APPLICATION 1,0 Development Services Department,240 West Huntington Drive, Post Office Box 60021 Arcadia, CA 91066-6021, (626)574-5416,Fax (626)447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor performance of the work for which this permit is issued. OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section ❑ 3700 of the Labor Code,for the performance of the work for which this permit I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number (This section need not be completed if the permit is for one hundred dollars or less) provisions of the Contractors License Law(Chapter 9(commencing with Section 7000)of Division 3 of the Business and Professions Code)or that he or she is ❑ I certify that in the performance of the work for which this permit is issued,I shall exempt there from and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale. If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044, Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). 0 I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for further information. Name Title PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature Date 8688-T9S-i56 d v 1 o a—..- walsAs 0 uwruflWp.tonuoptua9NMp 'm • ' o ouNn07 39N L0016 VJ�tlIOtlDUtl N N 4.3�a d LiSi bis?OI :Hd 3AV 1S3M N3O1O9 S ZZ8 D1emonolagd ugi nj • CS • m , r W LZ9£ZOi 3�N3O1S3a nm �0M�I4T'L N d 0 :A9 sueld Z Q Jo a Eo OR m N N '," o w W R o ' o i z I — I L •cif > a o I I I W u a w J m I Q .o Q — — — — 1 9 o ri Z I I U I Z 2 ,� I I Q° 5 I I W a rn 1 I a s Ico Ix 1 H N "" 72 > r, d Y 11 1 ,_< ow I - } W I Z3 I - - - - C v Q v) _ J 1 LL I o8ga i.. —tl311V MIaOM••• ; 0 Q 0 - - I w n I — � o o 1 I CO as I o O I 1__ ` 1 1 O. I $ Z , I o 1 03 I " � i a I z I / 1 _ J 1• • o o 11%111111 I 1 a dN °� I LL, CCw0 NC 0 Q 0 NG N ib I H J '�y� ~ CL I ❑ ❑ Li O3w I 0 Ill 1- No � Q w I I 1 Z W C m a j _. ❑O o'= I Q j0 va=, o rz Q1. • I W gQ ~ i� N ~ J,0 I Z J Q p z A elo ; w 6azFi N•� 0 E2M $ o w- . • — • • — . .WORK AREA• — .. — •• —I I 1 W z w W J IH 1 L 1 z w I >- >- i a a i I — _ _ I i • — — — p i • I >- acc Q I 6 Ne ON a m I_ I 1 I_0 I> CO co 0 3 I --zI — 03 1Ei z a — _ — J I 1- z 1 Nf O \ i z bi 0 o iv � I I I I 17- O 0 I * . m° f- Z 3CN 1 Q i Mjy C.�.. ZI N b0 S W U '• 2 w 1 c.,„EER •z w Uo i-o7v. 1 = ., .- o2� I c O 3a w f0 O I d p 1 w 1 z L .___. _ _. _.._.._.._ _.._ _. _ _ ._ ._.PROPERTY LINE _ ___. _. _ _ _. __i a ce STREET > cc vwi ? 0 O Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Te1:1 .310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Structural Calculations for a Roof Mounted Solar Photovoltaic System for: Jianwei Wu Residence liZoFESS/pN 822 S Golden W Ave., • �� p►!:� Arcadia, CA 91007 No. C58724 Applicable Codes: 4cExp.3-31-21 � civic- TeOF CA\-09' 2019 California Building Code, 2019 California Electric Code, 2019 California Mechanical Code, American Society of Civil Engineers Standard ASCE 7-16 Minimum Design Loads for Buildings and Other Structures, American Wood Council 2018 National Design Specification for Wood Construction, Local Municipal Code, and all other codes which are adopted by reference or enacted by law. Assumed Design Parameters: The existing structure has been built under a building permit and is in its original condition. The existing roof structure is capable of its code required live load and the ability of the roof structure to support live loads has not been substantially reduced by the age of the structure, termites or mold, or unauthorized modifications to the existing structure. Solar Energy Contractor shall make inspection of the existing roof framing system prior to installation of the roof mounted solar energy system to verify that the existing roof is capable of supporting minimum roof live loads. Assumed Design Parameters: All 2x members are grade Douglas Fir #2 or better All 4x members are grade Douglas Fir #1 or better All Roof Connectors are Simpsons Strong-Tie or Equal All Concrete Foundations are f'c = 2500 psi or stronger Original Structure was built to the Type-V Wood Framed Standards of the Applicable Building Code at the time of Construction. Sht # 1 of 7 2020-3044 ESD 20-757 - OC Solar Jianwei Wu Residence Date: February 09, 2021 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Te1:1 .310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Note to Building Official: Based upon a review of the proposed plans I am confident that the existing roof framing system is capable of safely supporting the additional loads caused by the solar photovoltaic energy system. The contractor shall field verify that the existing roof structure is in its original permitted condition and verify that it can support the normal code required roof live loads. Attached in this package are several calculations showing that the roof members can support the additional weight of the solar array. Furthermore, an analysis of the solar array's support for wind forces and a seismic analysis of the existing structure are also included. Check 2x8 Roof Framing @ 24" O.C.*: wDL+LL - - w = 36.9psfx2ft. = 73.8plf L R1 R2 -i- 17, Total load on framing = 73.8 plf x 17 ft. = 1,255 lbs .eskoFESS/oN,, • IVa � �m No. C58724 * Exp.3-31-21 * c>9TF AFI Al�F���\P *Note: Contractor to Field Verify Framing Sht # 2 of 7 2020-3044 ESD 20-757 - OC Solar Jianwei Wu Residence Date: February 09, 2021 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Te1:1 .310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Check 2x8 Roof Framing @ 24" O.C.: P P P P w LL 7 7 7 7/ ))J J))��� WDLV//////////////i//�////// A W DL+LL = 36.9 psf x 2 ft. = 73.8 plf L L R1 R2 17' 11 i 6' Total load on framing = 73.8 plf x 6 ft. +33.8 plf x 11 ft. + ( 6' x 2.75' x 3 psf x 4 ) = 1 ,013 lbs < 1,255 lbs OK Check attachment of Support to Existing Structure for Wind Uplift CHECK SOLAR STRUCTURE ATTACHMENTS PER ASCE 7-16 WIND LOADS ON BUILDING APPURTENANCES AND OTHER STRUCTURES Section 29.4.4 THEREFORE CHECK ATTACHMENT FOR TYPICAL CRITICAL LOAD WHICH IS THE EDGE ZONE - ZONE 2. NOTE: PER DEFINITION ON SHEETS 246 & 247 OF ASCE 7-16 EFFECTIVE WIND AREA: "FOR ROOFTOP SOLAR ARRAYS, THE EFFECTIVE WIND AREA IN FIG. 29.4-7 IS EQUAL TO THE TRIBUTARY AREA FOR THE STRUCTURAL ELEMENT BEING CONSIDERED, EXCEPT THAT THE WIDTH OF THE EFFECTIVE WIND AREA NEED NOT BE LESS THAN ONE-THIRD ITS LENGTH." .�OQROF ESS/o4,,41 EFFECTIVE AREA = 15 SQ FTo - 111110ky 0 No. C58724 * Exp.3-31-21 * CIV1L 9TF OF C AL\ QI- Sht # 3 of 7 2020-3044 ESD 20-757 - OC Solar Jianwei Wu Residence Date: February 09, 2021 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Te1:1 .310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Check attachment of Support to Existing Structure for Wind Uplift - Cont'd Tributary Area to Each Solar Mount = 6 ft. x 2.75 ft. = 16.5 sq. ft. ( Max ) Calculate Design Wind Pressure at each support (Wind Speed 130 mph Exposure C): p=gh(GCp)(yE)(ya) Eq'n 29.4-7 ASCE 7- 16 q1,=0.00256K,K,cKdKeV2 Eq'n 26.10- 1 ASCE 7- 16 Note: KZ = velocity pressure coefficient, Section 26.10.1 ASCE 7- 16 eROFESSo KZ = 0.9 (Exposure C, Height = 20 ft or less) ; Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1 .310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Check attachment of Support to Existing Structure for Wind Uplift - Cont'd Dead Load = 3.0 psf Wind Load = 42.0 psf Design (Factored) Load at each support: 3 psf + (0.6 x 42.0 psf) = 28.2 psf ><>01161<)<Mwhere: Y = Distance between 2 lag screws y Y = 2" 0111110• Y' = Moment arm to 1st lag screw j = 6" Moment due to Load = (28.2 psf x 16.5 sq. ft.) x 6 inches = 2,792 in-lb Load to lag screw = 2,792 in-lb / 2 in = 1 ,396 lbs Determine allowable load per 5/16" lag screw w/ 3" embedment into wood below according to the 2018 NDS. W ' = W x Cd x Ct Table 10.3.1 2018 NDS where: W = 266 lbs / in. of embedment per Table 12.2A Cd = 1.6 per Table 2.3.2 of 2018 NDS Ct = 1.0 per Table 10.3.4 of 2018 NDS W ' = 266 lbs/ in. x 3 in. x 1.6 x 1 .0 = 1 ,277 lbs rz 1,396 lbs OK QROF ESS/pN OK. Use Tile Hooks with (2) 5116" x 4" Lag Screws ��° • , . "/' with 3" min. embedment into wood, at 72" O.C. max, as per Plans to Manufacturer's instructions. 0 No. C58724 T * Exp.3-31-21 9T4'OF Cpl0°O Sht # 5 of 7 2020-3044 ESD 20-757 - OC Solar Jianwei Wu Residence Date: February 09, 2021 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Te1:1 .310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Check Seismic load due to added dead load of photovoltaic system. Determine Seismic Weight of Existing Building: Effective Existing Seismic Weight Area of (E) Building = Approximately 2,200 sq. ft. Approximate Effective = 2,200 sq. ft. x 30 psf ave. = 66,000 LBS Seismic Weight DETERMINE BASE SHEAR V = Cs W EQ'N 12.8-1 ASCE 7-16 Cs = SDS EQ'N 12.8-2 ASCE 7-16 le R = THE RESPONSE MODIFICATION FACTOR IN TABLE 12.2-1 R = 6.5 WOOD SHEAR WALLS le = 1.0 IMPORTANCE FACTOR 19;0FEss41; 4 4 xle SDs = 2/3 x SMS EQ'N 11.4-3 ASCE 7-16 LiE2 No. C58724 SMS= FA x Ss EQ'N 11.4-1 ASCE 7-16 * Exp.3-31-21 ::= 1 .5 = .2/3 x 1.8 = 1.2 1.2 Cs = 6.5 = 0.185 EQ'N 12.8-2 ASCE 7-16 - 1 Sht # 6 of 7 2020-3044 ESD 20-757 - OC Solar Jianwei Wu Residence Date: February 09, 2021 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224- 406 Orlando, FL 32819 Te1:1 .310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com EXISTING BASE SHEAR V = 0.185 x 66,000 LBS = 12,210 LBS EQ'N 12.8-1 ASCE 7-16 DETERMINE NEW BASE SHEAR Determine Seismic Weight of Building with Solar Array: EXISTING SEISMIC = 66,000 LBS WEIGHT NEW SOLAR ARRAY = 3 PSF x 21 PANELS x 3.3' x 5.5' = 1 ,143 LBS NEW SEISMIC = 66,000 LBS + 1 ,143 LBS = 67,143 LBS WEIGHT THEREFORE NEW BASE SHEAR: V = 0.185 x 67,143 = 12,422 LBS EQ'N 12.8-1 ASCE 7-16 12,422 LBS - 12,210 LBS % CHANGE = x 100 = 1.7 % < 10% OK 12,210 LBS OK. PER ASCE 7-16 SECTION 11.6.3 ALTERATIONS EXISTING LATERAL FORCE RESISTING SYSTEM IS EXEMPT FROM ANALYSIS SINCE NEW SEISMIC FORCE IS LESS THAN 10% GREATER THAN EXISTING SEISMIC FORCE. eckof. ESStp4M ,,4 „` "Alterations are permitted to be made to any structure without requiring the �. existing structure to comply with this standard provided the alterations comply with the requirements for a new structure. Alterations that increase the No. 058724 seismic force in any existing structural element by more than 10 percent or * Exp.3-31-21 decrease the design strength of any existing structural element to resist � C iV 1� �P seismic forces by more than 10 percent shall not be permitted unless the 9TF ° entire seismic force-resisting system is determined to comply with this �F C Al�F standard for a new structure.” End of Calculations Sht # 7 of 7 2020-3044 ESD 20-757 - OC Solar Jianwei Wu Residence Date: February 09, 2021 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Te1:1 .310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Determine Loading on Roof Framing ,s0FESS/04,, .�o Dead and Live Loads without Panels: •o e M�/ No. C58724 Tile Roofing = 8.0 psf 1/2 Sheathing = 1 .5 psf * Exp.3-31-21 * Framing @ 24" O.C. = 2.5 psf >25,, c'cA�\F°��\ 5/8" Drywall = 3.1 psf Misc. / Insul = 1.0 psf Dead Load = 16.1 psf w/ DL Corr. (1.05) = 16.9 psf Live Load = 20.0 psf Total Load = 36.9 psf Dead Loads with Panels: Tile Roofing = 8.0 psf 1/2 Sheathing = 1.5 psf Framing @ 24" O.C. = 2.5 psf 5/8" Drywall = 3.1 psf Misc. / Insul = 1.0 psf Dead Load = 16.1 psf w/ DL Corr. (1 .05) = 16.9 psf Total Load = 16.9 psf Solar Array = 3.0 psf (Note: Solar Loads are point loads on members) Total Load with Solar Array = 19.9 psf < 36.9 psf OK Sht #R1 2020-3044 ESD 20-757 - OC Solar Jianwei Wu Residence Date: February 09, 2021 �� (..11.1 ilia ,,,,i hsw...MN \-ALAN I.IM) \ \C• Y. '-&t7 o_-' AFFIDAVIT SELF-CERTIFICATION FOR COMPLIANCE OF SMOKE ALARMS AND CARBON MONOXIDE ALARMS Property Address: '6 "L 2 S 6-1)(._“/ 1,) .-_.c7- AY AJJ- ( 4 o r4 , L� Permit Number: s e i.le - 2 l - O - S l Brief Job Description: ,-n. - M o u r+r'L o s uul a- /t r r-A c tit n0^l Number of smoke alarms installed: 5- Number of carbon monoxide alarms installed: Z When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created, Smoke alarms shall be installed in each sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2013 California Residential Code (CRC) and California Health and Safety Code Section 13113.7. For dwellings or sleeping units containing fuel burning appliances or having attached garages, carbon monoxide alarms shall be installed outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements as required by Section R315 of the of the 2010 California Residential Code (CRC). Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used. All alarms shall comply with requirements for listing and approval by the Office of the State Fire Marshall. http://osfm.fire.ca.qov/licensinglistings/licenselistinq bml searchcotest.php As owner of the above referenced property, I hereby certify that the smoke alarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance with the code sections referenced above. I declare under penalty of perjury that the foregoin is true and correct, and that this declaration was executed on (Date) V 3 /G a -2„,c,-7, / at Arcadia, California. Owner's Name (printed/typed): 3----Ac c.re kii J - Signature of Owner: AEEEE ::::::;:T::lF .- - This affidavit must be ret • - . to the City of Arcadia inspector prior to final inspection