Loading...
HomeMy WebLinkAboutSOLR-20-2019 •• r City of Arcadia, CA Permit NO.SOLR-20-2019 Development Services Department Permit Type:Solar 240 West Huntington Drive,Post Office Box 60021 Arcadia,CA 91066-6021 Work Classification:Solar-Residential (626)574-5416 Permit Status:Issued • ARCADIA Issue Date: 12/03/2020 Expiration: 12/03/2021 , Addr NO. Dir Prefix Street Name • Street Suffix Unit City,State,Zip Parcel Number 507 S THIRD AVE B Arcadia,CA 91006-3808 5779008094 Contacts CHAN CHAN Owner TESLA ENERGY* Contractor 507 THIRD AVE B 3055 Clearview Way,San Mateo,CA 94402 (909)560-5009 (323)240-3174 - 888104 Description:ROOF MOUNTED SOLAR SYSTEM 14 Valuation: $ 0.00 Tenant MODULES/INVERTER Total Sq Feet: 0.00 Plan Check# Plan# - , Fees Amount Payments Amount Paid Building Plan Check Fee Residential $100.00 Total Fees $324.72 Distribution Panel $16.48 Cash/Receipt#REC-06215-20 $324.72 Electrical Permit Issuance Fee $47.01 Inverters Amount Due: $77.78 $0.00 Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $324.72 - 3 ....._?.......1 CALLS FOR INSPECTIONS f--1(4 Request for inspection by telephone at 626-574-5450. Leave a message Al---'� requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Ei COMPLEIEOArcadia building inspector for a period of 180 consecutive days. December 03,2020 Issued By: Date December 03,2020 Page 1 of 1 ate; ► PERMIT/PLAN REVIEW APPLICATION 11 ?:`• Huntington Drive,Post Office Box 60021 t#;t• Development Services Department, 240 West g °0mtl1.1,,,,,.°s� Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Signature of Contractor ❑ I have and will maintain workers'compensation insurance,as required by Section OWNER-BUILDER DECLARATION 3700 of the Labor Code,for the performance of the work for which this permit 0 I hereby affirm under penalty of perjury that I am exempt from the Contractors is issued.My workers'compensation insurance carrier and policy numbers are: License Law for the following reason(Section 7031.5,Business and Professions Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number for such permit to file a signed statement that he or she is licensed pursuant to the (This section need not be completed if the permit is for one hundred dollars or less) provisions of the Contractors License Law(Chapter 9(commencing with Section 7000)of Division 3 of the Business and Professions Code)or that he or she is ❑ I certify that in the performance of the work for which this permit is issued,I shall exempt there from and the basis for the alleged exemption. Any violation of not employ any person in any manner so as to become subject to the workers' Section 7031.5 by any applicant for a permit subjects the applicant to a civil compensation Laws of California,and agree that if I should become subject to the penalty of not more than five hundred dollars($500)): workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for Date Signature sale(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044, Business and Professions CONSTRUCTION LENDING AGENCY Code:The Contractors License Law does not apply to an owner of property who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). 0 I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS ANI) RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for further information. Name Title PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature Date `omilw A� ' " l � � d bswM.Mtt ift-tarta-5-7,-N Aywl f.IMS i I, o. AFFIDAVIT SELF-CERTIFICATION FOR COMPLIANCE OF SMOKE ALARMS AND CARBON MONOXIDE ALARMS Property Address: co c_ {J L{,,,,i- (3 «(;,,, e-,, C p, c-- ,,c, (6., Permit Number: 501,12.- M) , )0(9 Brief Job Description: Zr 19/0D- . VR.©tivi/ae-ok c4 ax cv S v`— Number of smoke alarms installed: 7 r Number of carbon monoxide alarms installed: ) When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created, Smoke alarms shall be installed in each sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2016 California Residential Code (CRC) and California Health and Safety Code Section 13113.7. For dwellings or sleeping units containing fuel burning appliances or having attached garages, carbon monoxide alarms shall be installed outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements as required by Section R315 of the of the 2016 California Residential Code (CRC). Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used. All alarms shall comply with requirements for listing and approval by the Office of the State Fire Marshal. http://osfm.fire.ca.qov/licensinglistings/licenselistinq bml searchcotest.php As owner of the above referenced property, I hereby certify that the smoke alarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance with the code sections referenced above. I declare under penalty of perjury that the foregoing is true and correct, and that this declaration was executed on (Date) ___� 2. . .)- ___e at Arcadia, California. Owner's Name (printed/typed): V l V\U r 1Sl ^0 0 Signature of Owner: Vai," This affidavit must be returned to the City of Arcadia inspector prior to final inspection SMOKE ALARM AND CARBON MONOXIDE ALARM LOCATIONS Guest Room � L Bathroon U Storage ( 1 . \-_, L Family Room NM NM NM 11111111 NM Garage FIRST FLOOR PLAN •= SMOKE ALARM I = CARBON MONOXIDE ALARM lI III' O Mstr L_ Bath Pi Master Bedroom Dining Room Kitchen 30 — l3ntlh C0.2 ).. .__ ___4_ ' C Han c,i� AE! tk: LcIoset Family Room Bedroom Bedroom _—, SECOND FLOOR PLAN it = SMOKE ALARM r = CARBON MONOXIDE ALARM JL I W IC 0nH N O N 5. 5. cN 5. x. ._. .„ -. % Ill 1`? yC a i z C C < < W _ NN �O fQ F w ; N m N = III U& Y o = pF en I= p rnF W ' 3c� = z k' a R _.zz g a Z n � h0 �ch� n mN h J � �z 1= F z o CV 5� � 0 �� gw— (/) a Vf yy X f f f a O E® Y®E1� O O ® O I 1 I OL_J .. D E[ O Opp O M E #GrE. IR 4.- 3QQ��° 4, p, , Ns '' cc cc > d Z 3 J CL 4.0 r` r.„—.._...;v 1 in -= I LJ, �.J I - 507 S 3rd Ave, B ..74 1 i 4- it a Ea \ u1 m co °��IL �©1 �, / U� o O / • v)o co / ON. 0 rn 3� ' /./. // U Q OOi in 1 0 N 6,'S' ' /�j o, 2 / U- I ' CIO 11111-111 ." V 4 t•-,: 11-11111ii.i ill // z ■ (111) o o § ' o 2 al d ro / /i /44 � klOV,- '. v m d 7r �i�. RAZ, o 6 M 4 ”` a - 3 itis pg1 Z idly p_ _n g W Iig J=3g 0114 Version#87.0-1 NAS November 4,2020 RE: CERTIFICATION LETTER Project/Job#JB-9103804-00 Project Address: Chan Residence 507 S 3rd Ave Arcadia,CA 91006 AHJ Arcadia SC Office Atwater Village Design Criteria: -Applicable Codes=Structure:2019 CEBC;PV:2019 CBC/CRC,ASCE 7-16,and 2018 NDS -Risk Category=II -Wind Speed=100 mph,Exposure Category C,Partially/Fully Enclosed Method -Ground/Roof Snow Load=0 psf -MP1:Roof DL=15.5 psf,Roof LL=20 psf -MP2:Roof DL=15.5 psf,Roof LL=20 psf -MP3:Roof DL=15.5 psf,Roof LL=20 psf -MP5:Roof DL=15.5 psf,Roof LL=20 psf Per Section 1613.1,W-(PV)/W-(exist roof)=2.8%,Increase Seismic Shear Load< 10%,->(OK] To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. Installer shall verify existing roof framing is in suitable condition and does not exhibit any signs of structural damage which may diminish the capacity of its members or connections prior to commencement of PV installation.Installer verification of the mounting planes noted above is required because some or all of the framing was not observed prior to the structural evaluation performed for this report. Paul Zacher,P.E. Professional Engineer QRpFESS10^, T:916.961.3960 x101E T ! email: paul@pzse.com O.5, • au! m No S3878 Exp.3.31-21 SjRU Mkt GAO"c OF GAO 11-05-2020 Tesla,Inc. T = 5 L n IT ~ 4,- Version#87.0-1 - NAS HARDWARE DESIGN AND STRUCTURAL EVALUATION RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1 72" 24" 52" 24" Not-Staggered 70.7% MP2 72" 24" 52" 24" Not-Staggered 70.7% MP3 72" 24" 52" 24" Not-Staggered 70.7% MP5 72" 24" 52" 24" Not-Staggered 70.7% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1 64" 20" 52" 24" Not-Staggered 62.8% MP2 64" 20" 52" 24" Not-Staggered 62.8% MP3 64" 20" 52" 24" Not-Staggered 62.8% MP5 64" 20" 52" 24" Not-Staggered 62.8% Mounting Plane Roof Pitch Qualification Results (Degrees) Member Evaluation Results MP1 18° Member Impact Check OK MP2 18° Member Impact Check OK MP3 18° Member Impact Check OK MP5 18° Member Impact Check OK Tesla,Inc. T = 5 L n Version#89.8-1 NAS February 8,2021 RE: CERTIFICATION LETTER Project/Job#9103804 Project Address: Yen Residence 507 S 3rd Ave Arcadia,CA 91006 AHJ Arcadia SC Office Atwater Village Design Criteria: -Applicable Codes=Structure:2019 CEBC;PV:2019 CBC/CRC,ASCE 7-16,and 2018 NDS -Risk Category=II -Wind Speed= 100 mph(3-s Gust-Vult),Exposure Category C,Partially/Fully Enclosed Method -Ground/Roof Snow Load=0 psf -MP1:Roof DL= 15.5 psf,Roof LL=20 psf -MP2:Roof DL= 15.5 psf,Roof LL=20 psf -MP3:Roof DL= 15.5 psf,Roof LL=20 psf -MP5:Roof DL= 15.5 psf,Roof LL=20 psf Per Section 1613.1,W-(PV)/W-(exist roof)=2.8%, Increase Seismic Shear Load< 10%,->[OK] To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. Installer shall verify existing roof framing is in suitable condition and does not exhibit any signs of structural damage which may diminish the capacity of its members or connections prior to commencement of PV installation.Installer verification of the mounting planes noted above is required because some or all of the framing was not observed prior to the structural evaluation performed for this report. Paul Zacher,P.E. Professional Engineer T:916.961.3960 x101 ' QROFESSic ,q email: paul@pzse.com co�cL 1 BENNE T{ rq y Fyc/ y m cc No 53878 Exp 3-31.21 ��gTSTRUCTURP�" ��� OF cA�\FO 02-08-2021 DIGITALLY SEALED Tesla,Inc. 3055 Clearview Way,San Mateo,CA 94402 T ESL P'i p 650 638 1028 f 650 638 1029 Version#89.8-1 NAS HARDWARE DESIGN AND STRUCTURAL EVALUATION RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1 72" 24" 52" 24" Not-Staggered 70.7% MP2 72" 24" 52" 24" Not-Staggered 70.7% MP3 72" 24" 52" 24" Not-Staggered 70.7% MP5 72" 24" 52" 24" Not-Staggered 70.7% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1 64" 20" 52" 24" Not-Staggered 62.8% MP2 64" 20" 52" 24" Not-Staggered 62.8% MP3 64" 20" 52" 24" Not-Staggered 62.8% MP5 64" 20" 52" 24" Not-Staggered 62.8% Roof PitchQualification Results Mounting Plane (Degrees) Member Evaluation Results MP1 18° Member Impact Check OK MP2 18° Member Impact Check OK MP3 18° Member Impact Check OK MP5 18° Member Impact Check OK Tesla,Inc. T = 5 L n 3055 Clearview Way,San Mateo,CA 94402 p 650 638 1028 f 650 638 1029