HomeMy WebLinkAboutSOLR-21-1073 �,•� ; City of Arcadia, CA, Permit NO.SOLR-21-1073
Development Services Department Permit Type:Solar
240 West Huntington Drive,Post Office Box 60021 Work Classification:Solar-Residential
Arcadia,CA 91066-6021
(626)574-5416 Permit Status:Issued
ARCADIA Issue Date:06/14/2021 1 Expiration: 06/14/2022
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
[1407 OAKLAWN PL Arcadia,CA 91006-2143 5769018008
Contacts
WANG,SHUNDE AND JIANG,NAN NAN Owner FREEDOM FOREVER LLC* Contractor
1407 OAKLAWN PL 3322 GARFIELD AVE,COMMERCE,CA 90040
(626)225-6198 (213)908-8229 1029644
Description:ROOF MOUNTED SOLAR SYSTEM 26 Valuation: $0.00 Tenant
MODULES/OPTIMIZER AND 1 INVERTER
Total Sq Feet: 0.00 Plan Check# _ Plan#
1 "1
Fees Amount Payments Amount Paid
Building Plan Check Fee Residential $100.00 Total Fees $308.24
Electrical Permit Issuance Fee $47.01 Cash/Receipt#REC-07909-21 $308.24
Inverters $77.78
Panels $82.45 Amount Due: $0.00
Solid Waste Management Fee 2 $1.00
Total: $308.24
CALLS FOR INSPECTIONS
Request for inspection by telephone at 626-574-5450. Leave a message
requesting the address,timeframe and what inspection item is needed.
This permit/plan review expires by time limitation and becomes null and
void if the work authorized by the permit is not commenced within 180 days
from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 consecutive days.
7 COMPLETED
June 14, 2021
Issued By:John Zurick Date
June 14,2021 Page 1 of 1
iF AR
PERMIT/PLAN REVIEW APPLICATION
il o 4#j�, Development Services Department, 240 West Huntington Drive, Post Office Box 60021
Arcadia, CA 91066-6021, (626) 574-5416, Fax (626) 447-9173
City of
Arcadia
CENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions C e,and my license is in full force andct. ❑ I have and will maintain a certificate of consent to self-insure for workers'
License Clasp -CI 0 License No.I021 J// '�,� Exp. Date 7//Zf compensation, as provided for by Section 3700 of the Labor Code, for the
((( performance of the work for which this permit is issued.
Signature of Contractor
OWNER-BUILDER ECLARATION I have and will maintain workers'compensation insurance,as required by Section
❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
License Law for the following reason(Section 7031.5,Business and Professions is issued.My
worke-rs'compensation insurance carrier and policy numbers are:
Code.Any city or county which requires a permit to construct,alter,improve, Carrier Re Wim! F tit
demolish,or repair any structure,prior to its issuance,also required the applicant —7L Z.. Jig G 8
for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number k'
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less)
7000)of Division 3 of the Business and Professions Code)or that he or she is
exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions of Sec n 3700 of the Labor Code,I shall
❑I, as owner of the property, or my employees with wages as their sole forthwith c ply ith those provisions.
compensation,will do the work,and the structure is not intended or offered for /
sale(Section 7044,Business and Professions Code:The Contractors License Date Z( Signatu
Law does not apply to an owner of property who builds or improves thereon, `
or who does such work himself or herself or through his or her own
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(I)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044, Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
Date Signature Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for
further in ormation.
Cc/durmaation. )
Name C, c/dN a r1 f/ Title Q•ei/'A t OOitclrN"-Tb/
PRINT NAME
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the above-mentioned property for inspection purposes. //07
C________74:9
Signature7
Date
co Z ZNTpmOOu
rr
gigh N;g'48h
m Wg ;rvL2= YioIN
A .°i=yT�^ gmqi Yif 2
D m zn,mfmjtim wN
mm m >ng>o>o > o y;y
Ct.,'
p� A S N A O m p i m L01 P
0)
°z�PA zOgg
A r i, mm3 g ,i o
II D m A P$8iig
Tz O_
W.-
o�� T
`, SZjp > o NO
,, ..� ZNi $ O Z
y `Li " Z
74'-7" taw+�'•'�- \ r pp >Z
.r/"•• mo w •\ AlS�pil A;AAI AP
...--••.r•� .` 41ymZOOP Z=� 2nya�.
_�.. mNmip AmO pV
O TONp >DS 0%
I \ NRI
Oqm"mA""J•
LI RI
.. ,12, 0A§ gl,§?,
9 , \ o om>z x£ xHR
mirHm _'< H5,
W,
1 3362 zg§ IAD
{ ,_ §�� H A
s.
Hm «H.
,` ? mm N DSv � �
1
r0 CF
!:\ •\ D 2 { m 07 D
m o n _r no
< O m m A A y
'\ n m
m <, vyi H �cYf
I • N 2 D D n rti<
\N Z A fVA D 2
'\ m
O r •" N O y A
y z o m
o o 11111 •\ m \wpm
O O \ A \ m''
\IF
° o m?
I o o `
0 o r
0 0
o p / ii V k
0 0
8iNZ E o \
2
< � -- gooz
03,,- E ` ?nom
C
;16r7_,T
y O
o ; y
r D �
n{ • �. —_ ..–_... --. .___ --_ SOD
, \
O D
131 :` hl•
o• mY nv
X N 0
W
1 T•_. ..,a.,.. !1149'•8' A O
z
M73 A
p r:.
n
0> m r a
A
_ y
1. n OAKLAWN PL m
QQ ggp qq 3,3,_ gt, 2{
, f WIN er
ill
„. t
Cn n� O O '° o 4. i go�8ap ":0:25,15,1
g E i 5 89 Z - :n ss ! lb > 8,AgRa maC)
m 3 F l r• d Z on lb n r m 2€1,..c :F �m�,
2 0; 00 , x< F`£ '1 m (Dand ^ �
Z :
.Ta D N c ter: i. ? _a z T I,' ; g!<m
y z
h O 3 m 1 N ,i - = nplwN.
Current
•
Renewables
Engineering
6/9/2021
Freedom Forever LLC
43445 Business Park Dr Suite 110
Temecula, CA 92590
Attn.:To Whom It May Concern
re job: Jiang, Nannan
1407 OAKLAWN PL,
ARCADIA,CA 91006
The following calculations are for the structural engineering design of the photovoltaic panels and are valid
only for the structural info referenced in the stamped plan set.The verification of such info is the
responsibility of others.
After review, I certify that the roof structure has sufficient structural capacity for the applied PV loads.
All mounting equipment shall be designed and installed per manufacturer's approved installation
specifications.
Design Criteria:
Code: 2019 CBC
ASCE 7-16
Live Load: 20 psf
Ult Wind Speed: 96 mph
Exposure Cat: C
Ground Snow: 0 psf Min Roof Snow: NA
,(...„....„,,,,,,e
re z m te,,,,e,t
Current Renewables Engineering Inc. I
Professional Engineer
info@ currentrenewableseng.com
j� CNCALFtt !
OF
EYP• 03/31120ZZ
Date :6/9/2021
C) Current Job Code:Jiang, Nannan
Renewables 2 of 6
Engineering
Roof Properties:
Roof 1
Roof Type= Tile
Roof Pitch (deg) = 20
Mean Roof Height(ft) = 13
Attachment Trib Width (ft) = 2.75
Attachment Spacing(ft)= 4
Framing Type= Rafter
Framing Size= 2x8
Framing OC Spacing(in.)= 16
Section Thickness, b (in.)= 1.5
Section Depth, d (in.)= 7.25
Section Modulus,Sx(in.^3)= 13.1
Moment of Inertia, lx(in.^4)= 47.6
Framing Span (ft)= 16
Deflection Limit D+L(in.)= 3.2
Deflection Limit S or W(in.)= 2.13
Attachments Pattern = Fully Staggered
Framing Upgrade= Adequate
Sister Size= NA
Wood Species= DF#2
Wood Fb (psi)= 900
Wood Fv(psi)= 180
Wood E(psi)= 1600000
CD(Wind)= 1.6
CD(Snow)= 1.15
CLS= 1.15
CM =Ct=CL=C;= 1.0
CF= 1.2
Cf„= 1.00
Cr= 1.15
F'b_wind (psi)= 2285
F'b_snow(psi)= 1643
F'v_wind (psi) = 288
F'v_snow(psi)= 207
M_allowable_wind (lb-ft) = 2503
M_allowable_snow(lb-ft) = 1799
V_allowable_wind (lbs) = 2088
V_allowable_snow(lbs) = 1501
E' (psi)= 1600000
Date :6/9/2021
1) Current Job Code:Jiang, Nannan
n '
Renewables 3 of 6
Engineering
Load Calculation:
Dead Load Calculations:
Panels Dead Load (psf) = 3.0
Roof 1
Roofing Weight(psf) = 9.0
Decking Weight(psf) = 2.0
Framing Weight(psf) = 1.9
Misc.Additional Weight(psf)= 1.0
Existing Dead Load (psf)= 13.9
Total Dead Load (psf) = 16.9
Wind Load Calculations:
Ultimate Wind Speed (mph) = 96
Directionality Factor, kd = 0.85
Topographic Factor, kzt= 1.0
Roof 1
Velocity Press Exp Factor, kz= 0.85
Ground Elevation Factor, ke= 1.00
Velocity Pressure,qz(psf)= 17.0
Array Edge Factor,yE= 1.25
Solar Equalization Factor,ya = 0.64
External Pressure Up, GCp_1= -2
External Pressure Up,GCp_2= -2.6
External Pressure Up,GCp_3 = -3.1
External Pressure Down, GCp= 0.6
Design Pressure Up, p_1 (psf)= -27.4
Design Pressure Up, p_2 (psf)= -35.7
Design Pressure Up, p_3 (psf)= -42.5
Design Pressure Down, p(psf) = 16.0
Hardware Checks:
Lag Screw Checks:
Roof 1
Ref. Widthrawal Value,W(lb/in) = 266
(Cm=Ct=Ceg= 1.0) CD= 1.6
Adjusted Widthrawal Value, W' (lb/in) = 426
Lag Penetration, p (in.) = 2.5
Allowable Widthrawal Force, W'p(lbs) = 1064
Date :6/9/2021
/;007_ ,t) Current Job Code:Jiang, Nannan
n
Renewables 4 of 6
Engineering
Applied Uplift Force(lbs) = -264
Uplift DCR= 0.25
Ref. Lateral Value,Z(lbs) = 270
(CM =C�=Co=Ceg= 1.0) Co= 0.9
Adjusted Lateral Value,Z' (lbs)= 243
Applied Laeral Force(lbs)= 11
Angle of Resultant Force, a(deg) = 88
djusted Interaction Lateral Value,Z'Q(lbs) = 1057
Lateral DCR= 0.01
Roof Framing Checks:
Force Checks:
Roof 1
LC1: D+S
Applied Moment(lb-ft)= 720
Applied Shear(lbs)= 180
Allowable Moment(lb-ft)= 1799
Allowable Shear(lbs)= 1501
Moment DCR= 0.40
Shear DCR= 0.12
LC2: D+0.6W
Applied Moment(lb-ft) = 1129
Applied Shear(lbs) = 282
Allowable Moment(lb-ft)= 2503
Allowable Shear(lbs)= 2088
Moment DCR= 0.45
Shear DCR= 0.14
LC3: D+0.75(S+0.6W)
Applied Moment(lb-ft)= 1027
Applied Shear(lbs)= 257
Allowable Moment(lb-ft)= 2503
Allowable Shear(lbs)= 2088
Moment DCR= 0.41
Shear DCR= 0.12
LC4:0.6 D+0.6 W
Applied Moment(lb-ft)= 270
Applied Shear(lbs)= 68
Allowable Moment(lb-ft)= 2503
Allowable Shear(lbs)= 2088
Moment DCR= 0.11
Date :6/9/2021
•
Current Job Code:Jiang, Nannan
Renewables 5 of 6
Engineering
Shear DCR= 0.03
Deflection Checks(Service Level):
Roof 1
LC1: D+L
Deflection (in.) = 0.65
Deflection Limit (in.)= 3.68
Deflection DCR= 0.18
LC2: S
Deflection (in.) = 0.00
Deflection Limit(in.)= 2.45
Deflection DCR= 0.00
LC3:W(Down)
Deflection (in.) = 0.17
Deflection Limit(in.)= 2.45
Deflection DCR= 0.07
LC4: W(Up)
Deflection (in.)= -0.30
Deflection Limit(in.) = 2.45
Deflection DCR= 0.12
Seismic Check:
Existing Weight:
Wall Weight(psf)= 17
Tributary Wall Area (ft2) = 1000
Total Wall Weight(lbs) = 17000
Roof Weight(psf) = 14
Roof Area (ft2) = 2400
Total Roof Weight (lbs) = 33286
Total Existing Weight(lbs)= 50286
Additional PV Weight:
PV Panel Weight(lbs) = 54
Number of Panels = 26
Total Additional PV Weight(lbs)= 1416
Weight Increase:
(Existing W+Additional W)/(Existing W)= 103%
The increase in weight as a result of the solar system is less than 10%of the existing structure and
Date :6/9/2021
OCurrent Job Code:Jiang, Nannan
Renewables 6 of 6
Engineering
therefore no further seismic analysis is required.
Limits of Scope of Work and Liability:
Existing structure is assumed to have been designed and constructed following appropriate codes at
time of erection, and assumed to have appropriate permits.The calculations produced are only for the
roof framing supporting the proposed PV installation referenced in the stamped planset and were
completed according to generally recognized structural analysis standards and procedures, professional
engineering and design experience,opinions and judgements. Existing deficiencies which are unknown or
were not observable during time of inspection are not included in this scope of work.All PV modules,
racking,and mounting equipment shall be designed and installed per manufacturer's approved
installation specifications.The Engineer of Record and the engineering consulting firm assume no
responsibility for misuse or improper installation.This analysis is not stamped for water leakage.
Framing was determined based on information in provided plans and/or photos, along with engineering
judgement. Prior to commencement of work,the contractor shall verify the framing sizes,spacings,and
spans noted in the stamped plans,calculations, and cert letter(where applicable) and notify the
Engineer of Record of any discrepancies prior to starting construction. Contractor shall also verify that
there is no damaged framing that was not addressed in stamped plans, calculations, and cert letter
(where applicable)and notify the Engineer of Record of any concerns prior to starting construction.