HomeMy WebLinkAboutSolr-21-1043 ,' ..ti k � , Per..rr�it No',SO LR'"211043..
City of Arcadia, CA qy
f, a' t: Development Services Department � �� :~ 'gyp r �' ,� Permit Type Solaro`
� 240 West Huntington Drive,Post Office Box 60021 { t �' i °2 I: - ' a� m°
Arcadia,CA 91066-6021 ,; w i� LW0rkiClessrficaa0n Solar ResldentiaI Overr 10 KV:
!_ (626)574-5416 11r i "n 1 r 44x "Y"'A" 'a i Permit�'tgtus Issued
A. 'cAi1 �� Issue;Date 06/09/2021�� Expiration 06/09/2022
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
AVE 1015 S TENTH Arcadia,CA 91006-4504 5780020067
Contacts
Brian Machida Owner SUNLUX* Contractor
1015 10th 8(00 S ROCHESTER AVE B,ONTARIO,91761
(909)210 0924 1008374 n
Description:ROOF MOUNTED SOLAR SYSTEM 36 Valuation: $ 0.00 Tenant
MODULES/MICROINVERTERS 100A LOAD CENTER
Plan Check#Total Sq Feet: 0.00 Plan#
Fees Amount Payments Amount Paid
Building Plan Check Fee Residential $100.00 Total Fees $324.72
Distribution Panel $16.48 Cash/Receipt#REC-07856-21 $324.72
Electrical Permit Issuance Fee $47.01
Inverters $77.78 Amount Due: $0.00
-
Panels $82.45
Solid Waste Management Fee 2 $1.00
I Total: $324.72
Lav6—zl
CALLS FOR INSPECTIONS
�` , by telephonemessage
l I�/_ 1l reqRequestuestingfor the addressinspection,timeframe ea what626-574-5450.inspection Li isneededa msag.
J
This permit/plan review expires by time limitation and becomes null and
void if the work authorized by the permit is not commenced within 180 days
from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
i CO1PLETED voidconsecutive if any work days authorized
no by thisprogressive permit ishas suspendedbeen or
verified abandonedbyaCity forof 180
if
Arcadia building inspector fora periodwork of 180 consecutive days.
•
June 09, 2021
Issued By:Jeff Wang Date
June 09,2021 Page 1 of 1
of ARC
0,1F07N.,99Ar
PERMIT/PLAN REVIEW APPLICATION
t
Development Services Department,240 West Huntington Drive,Post Office Box 60021
\Y 0 Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173
City of
Arcadia
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers'
License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
Signature of Contractor
OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section
❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are:
Code.Any city or county which requires a permit to construct,alter,improve, Carrier
demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number
for such permit to file a signed statement that he or she is licensed pursuant to the
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less)
7000) of Division 3 of the Business and Professions Code)or that he or she is
exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions of Section 3700 of the Labor Code,I shall
❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions.
compensation,will do the work,and the structure is not intended or offered for
sale(Section 7044,Business and Professions Code:The Contractors License Date Signature
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
Date Signature Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for
further information.
Name Title
PRINT NAME
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the above-mentioned property for inspection purposes.
Signature Date _
CALCULATIONS FOR SOLAR PHOTOVOLTAIC PANELS:
Owner: Brian Machida
Address: 1015 S 10th Avenue,Arcadia, CA 91006
INDEX TO CALCULATIONS
Sheet Item
1-2 Wind parameters
3-4 Seismic parameters and determination of Fp
5 design loads, roof member check, wind uplift check, deflection
6 attachment check, rail span check
7 lateral check
Engineering Calculations Performed By: ( 4`9`� t;� t\� t1i3`4;t
Doug Engineering •
20271 Lighthouse Lane, Huntington Beach,16A 92646- ', °4 ` ' ' owt 't
� f b13`
949-285-5104 „ roils
ilitii 'L , ,
Engineering Calculations For: ; }c ;1.1,,11+)c
t.
SunLux -,�;,:�,ti i� ;11t };',r,;1 a;;d'1 c}t
10860 6th Street, Rancho Cucamongat'CA�,91�73O1`' , �' r' ��• :gt� " ``
(909) 390-1796 is`:'�;}''' ' ot� ;iYi:
Project Number: SLE-3430 0$;
Date: 12/22/2020
�3ctSSIoN
BASIS FOR DESIGN c? c� !".?
CODE: 2019 California Building Code �+s
ASCE 7-16
LIVE LOADS ' EXP 06130/22:.'
ROOF 20.0 psf CIVIL44~
SNOW 0.0 psf '
•
ASCE 7-16
FLUSH MOUNTED SOLAR PANELS
Type of Roof Hip
Roof Slope-0=Angle of plane of roof from horizontal, in degrees
0= 15 deg
Mean Roof Height-Eave height will be used for 0<= 10deg
h = 22 ft
Building dimensions s1 = 30 ft
s2= 40 ft
a= 10% of least horizontal dimension or 0.4h,whichever is smaller, but not less than 4% of the least
horizontal direction or 3 ft
a= 3ft
B= Horizontal dimension of building normal to wind direction, in ft.
B= 30 ft Horizontal dimension of building
Attachment Spacing
Effective Area A= 13 ft2
p = gn(GCp)(YE)(Ya) 29.4-7
FIGURE 30.3-2E Components &Cladding h<=60 ft: External Pressure Coefficients, (GCp), for
Enclosed and Partially Enclosed Buildings -Hip roofs 7<=20deg (Roof)
FIGURE 30.3-2F Components& Cladding h<=60 ft: External Pressure Coefficients, (GCp), for
Enclosed and Partially Enclosed Buildings -Hip roofs 7<=20deg(Overhang)
Velocity pressure Exposure Coefficients
ROOF OVERHANG Wind Exposure C
(GCp)down = 0.65 0.65 Kn= 1
(GCp)upzl = -1.69 -2.19 Kd = 0.85
(GCp)upz2r = -2.15 -2.85 KZ = 0.85
(GCp)upz2e = -2.42 -2.87 Ke = 1
(GCp)upz3 = -2.42 -3.37 7E = 1
Ya = 0.75
V = 110 mph
qh = 0.00256KZKztKdKeV2
qn = 22.4 psf
p = 16.8 *(GCp)
1
ASCE 7-16
Diagrams
I _ I I. .
1 irr
lit 0 PO
t t 110
i
1 t" i'
t I I i,
t I
1 i
ELEVATION
i T,= l r _
PLAN
Notation
a=10%of least horizontal dimension or 0.4h,whichever is smaller,but not less than either 4%of least horizontal
dimension or 3 ft(0.9 m).If an overhang exists,the edge distance shall be measured from the outside edge of
the overhang.The horizontal dimensions used to compute the edge distance shall not include any overhang
distances.
B=:Horizontal dimension of building measured normal to wind direction,in ft(m).
h=Mean roof height,in ft(m).
6=Angle of plane of roof from horizontal,in degrees.
Wind Pressures
Wind Down-All Zones 10.9 psf 10 psf, MIN
ROOF OVERHANG
Zone 1 -28.39 psf -36.79 psf
Zone 2r -36.12 psf -47.88 psf
Zone 2c -40.66 psf -48.22 psf
Zone 3 -40.66 psf -56.62 psf
All panels are in Zones 1 and 2e
ROOF OVERHANG
Use -36.12 psf -48.22 psf
0.6*W -21.7 psf -28.9 psf
2
ASCE 7-16
Soil Site Class = D
Seismic Use Group = I
SS = 2.568 Mapped Spectral Response acceleration in short periods
S1 = 0.979 Mapped Spectral Response acceleration at one second periods
Table 1613.2.3(1)
Values of Site Coefficient Fa
SITE CLASS SS<0.25 SS=0.5 SS= 0.75 SS= 1.0 SS>1.25 SS>1.5
A 0.8 0.8 0.8 0.8 0.8 0.8
B 0.9 0.9 0.9 0.9 1.0 1.0
C 1.3 1.3 1.2 1.2 1.2 1.2
D 1.6 1.4 1.2 1.1 1.0 1.0
E 2.4 1.7 1.3 - - -
F - - - - - -
Fa= 1.200 (interpolated) SMS= Fa*SS= 3.082
Min. 1.2 per 11.4.3
Table 1613.2.3(2)
Values of Site Coefficient Fv
SITE CLASS S1< 0.1 S1= 0.2 S1= 0.3 S1= 0.4 S1>0.5 S1>0.6
A 0.8 0.8 0.8 0.8 0.8 0.8
B 0.8 0.8 0.8 0.8 0.8 0.8
C 1.5 1.5 1.5 1.5 1.5 1.4
D 2.4 2.2 2.0 1.6 1.5 1.7
E 4.2 - - - - -
F - - - - - -
Fv= 1.700 (interpolated) SM1 = Fv*S1 = 1.664
SDS=2/3*SMS= 2.054 SD1 =2/3*SM1 = 1.110
SDS RISK CATEGORY SD1 RISK CATEGORY
> I, II - Ill I IV > 1, 11 I III IV
0 A A A 0. A A A
0.167 B B C 0.067 B B C
0.33 C C D 0.133 C C D
0.5 D D D 0.2 D D D
Seismic Design Category= E
3
ASCE 7-16
Seismic Use Group = I
Seismic Design Category = E
I = 1
SS = 2.568
S1 = 0.979
SMS = 3.082
SM1 = 1.664
R = 6.5
Height = 11.375
T= 0.035*hn^.75 = 0.21679
r(Reliability/Redundancy Factor) = 1
SDS = 2.054
SD1 = 1.110
(ASCE 7-16 12.8-2) CS= SDS/(R/I) = 0.3160 W
(ASCE 7-16 12.8-3) CS<= SD1/[(R/I)T] = 0.787 W
(ASCE 7-16 12.8-5) CS>_ .01 = 0.01 W
If S1>0.6g
(ASCE 7-16 12.8-5) CS>= 0.5*S1/[R/I] = 0.075 W
V(controls) = 0.3160 W
Determine Fp for seismic loading on attachments
Seismic Load on Nonstructural Components
Spacing of attachments 5.33 ft
Tributary width of attachments= 1/2 Panel length= 33.5 in
Ap= 14.9ft`
PV unit weight including racking = 3 psf
Wp= 44.63875 lb
Other mechanical/electrical components
ap= 1 Fp= 0.4apSDS*Wp/(Rp/Ip)(1+2z/h) 73.35 lb 13.3-1
Rp= 1.5
1,= 1 Fp<= 1.6SDS*IPWp 146.70 lb 13.3-2
SDS= 2.054
Wp= 44.63875 lb Fp>= 0.3SDS*IPWp 27.51 lb 13.3-3
z= 22 ft
h= 22 ft
1
4
PROJECT: PV Panels for Brian Machida SHEET: 5 OF 7
CLIENT: SunLux DATE: 12/22/2020
BY: Doug Engineering DE JOB NO.: SLE-3430
DESIGN LOADS
Dead Loads Uplift
Roof 0.6WL
COMP SHINGLE 4.0 psf 0.6WL Zone 1 and 2e -21.7 psf, MIN 10 PSF
5/8" Ply shtg 1.9 Overhang -28.9 psf
Rf Frm'g 2.8 PwLdown= 10.9 psf 10 psf, MIN 10 PSF
Misc. 1.5 Uplift 0.6DL+0.6WL
(N) PV System 3.0 Zone 1 0.6*3-21.7 -19.9 psf
Zone 2 0.6*3-28.9 -27.1 psf
Total DL 13.2 psf Downward DL+0.6WL
LL 20.0 psf Poi+WL= 13.0 psf
SNOW 0.0 psf
Rafter Check
Existing 2x8 RAFTERS @ 16"o.c
Spacing 1.33 ft Trib panel width = 5.33 ft
E 1500000 psi Fb= 900*1.2*1.15 1242 psi
47.6 in^4 Maiiowwind= 2176 ft-lb
Span1 16.66 ft MaiiowLL= 1700 ft-lb
Span2 0.00 ft See below for Wind Uplift loads
Span3 0.00 ft due to concentated loads at attachments
Span4 0.00 ft
(Distance Wind Mmax Wind P=
to Att. Load Trib W Uplift wind(ft- Down PVDL P=DL+WL
Pts) a b R1 (Ib) R2(lb (psf) (ft) (Ib) Ib) (Ib) (Ib) (Ib)
-1.50
1 -0.50 -0.50 17.16 442.3 -12.9 28.9 5.3 429.4 -215 148.6 44.6 193.1
2 3.08 3.08 13.59 262.9 59.5 21.7 5.3 322.4 808 148.6 44.6 193.1
3 5.08 5.08 11.59 224.2 98.2 21.7 5.3 322.4 1138 148.6 44.6 193.1
4 8.65 8.65 8.01 155.0 167.4 21.7 5.3 322.4 1341 148.6 44.6 193.1
9.65
Span 1 Uniform DL 16.66 68.0 68.0 6.1 psf 1.3 8.2 plf 283.1
Reactions at Span1 1152.3 380.2 Negative values are uplift reactions
Mmaxwindup= 1877 ft-lb<2176 ft-lb OK
Mmaxwinddown= 1985 ft-lb<2176 ft-lb OK
For DL+LL including the PV system weight point loads w= 40.3 plf P= 44.6 lb
Mmax= 1652 ft-lb< 1700 ft-lb OK
Deflection Check
DDT=5wL4/(384EI) (5*13.2*16.66^4)*1728 = 0.427 in = L/ 468.2 OK
384*1.5E6*47.6
PROJECT: PV Panels for Brian Machida SHEET: 6 OF 7
CLIENT: SunLux DATE: 12/22/2020
BY: Doug Engineering DE JOB NO.: SLE-3430
CHECK SCREW ATTACHMENTS FOR WIND UPLIFT
Pwuplln= 429.4 lb 5/16" Lag with min 2.5"penetration for each attachment
Table 12.2A-NDS-Lag Screw Withdrawal Values
For 5/16"Lag into .5G wood 266 lb
Allowable wind load= 1.6*2.5*266 1064 lb > 429.4 lb OK
CHECK SCREW ATTACHMENTS FOR SHEAR DUE TO SEISMIC Fp
Fp= 73.35 lb
Roof slope/module tilt 15 deg
Shear= Fp*cos( 15 )= 70.9 lb 1\ Fp sin(ang)
Tension= Fp*sin( 15 )= 19.0 lb
Fp cos(ang)
Table 11 K-NDS Z= 190 lb
CD= 1.6
Z'= Z*Co= 304 lb> 70.85 lb OK Withdrawal capacity W= 1064 lb
Interaction Equation ft/Ft+f/F„ 0.421 + 0.233 = 0.654 < 1 OK
RAIL SPAN CHECK '
Everest Railing Check-Gable/Hip Roof
Load for half a panel=2.7'
w= 57.78 plf
Per the Everest Engineering for 110 mph, 0 psf snow, and 15 deg roof slope,the max span
for Crossrail48-X is 96"for Array Interior Panels and 72"for Array Array Edge panels
Use Crossrail48-X PV Rails with a spacing of 64"o.c. max for attachment points,typ.
Everest Solar 48-X Flush-Mount Dual Rail,Enclosed Hip/Gable Roof 0-30ft,72 Cell(L)Rail Only
Grauiscf Exposure UUirid 5peecl 110 mph"
,Snow Load, Category. Panel Angle Roof Zone > 1' 1 2e 2r 2n 3e 3r
0;ta.7 Array Interior 112 102. 91 91 91 81 81
Array.Edge 111 88 79 79 79 70 70
7 to 20 Array Interior 96 96 96 83 83 83 78
Array Edge 83 83 83 72 72 72 66
0 p`sf;;' C 20 to 27 Array Interior 106 106 106 88 88 88 86
Array.Edge 92 92 92 76 76 76 74
2'7 to 45 Array.Interior 99 99 99 99 95 88 95
Array Edge+: S5 85 85 85 82 76 82
45,to 90 Array Interior 112 112 107 107 107 107 107
Array.Edge 99 99 93 93 93 93 93
PROJECT: PV Panels for Brian Machida SHEET: 7 OF 7
CLIENT: SunLux DATE: 12/22/2020
BY: Doug Engineering DE JOB NO.: SLE-3430
LATERAL ANALYSIS
DETERMINE ADDITIONAL LOAD COMPARED TO EXISTING FOR LATERAL LOADING
Aroofexsting = 2697 sf Wpanei= 43.0 lb
Wroofexisting= 10.2*2697 = 27509 lb 36 *Wpanei = 1548 lb
Wwaiiexisting= 15*80*4 = 4800 lb Wrestofarray= 460.8 lb
Wexisting= 32309 lb Warray= 2008.8 lb
V= 0.316 W
Vroofexisting= 10210 lb Existing Total Lateral Force
Vroofwpaneis= 10845 lb New Total Later Force
% increase= 10845 *100%-100% = 6% increase which results in less than a 10% increase in the
10210 stress of existing lateral resisting elements OK
SITE PLAN SCALE: 1":15'-O" 'HOUSE PHOTO SCALE: N.T.S. 13
MICROINVERTER A� ARRAY LOCATION 1; 6-
WITH BUILT IN ,1, is t S,ttt r/ v;�fit'^ rim
RAPID SHUTDOWN :.+v 1 .�'� §$o
LOCAMODULE EACH =+y� a sty .3.,,-.... . t 4'8 u
85 4" j 4� • ?$T�"m
wf / 9 GF
N , yt �527 \ c apt' -Px,,,, ,R`/ `' fie.
i /4 ,1 r ,,:r5
I\� I , t'f '4 R 1. i ht ,1,F i 4 Din
. ,.}hr v� 1 77i t..
1.
B3 I _
B3 1 B3 z SITE PLAN LEGEND
0 83 ❑ e1 f_ '4 0(E)TWO-STORY HOUSE
B3 B1 B1 m =
©(E)DRIVEWAY
B3 B2 ❑ _ B1 ~0 0(N)SOLAR PV ARRAY PER TABLE BELOW N
B3 82 B2 B1 B1 - I = 0 FIRE ACCESS POINT o
I 63 • ° U s1 I M Q5 (E)PATIO COVER
o I B2 B2 00 B1 B1 B1 L Q a
-0/B3 B2 B2 B1 (/) La,R o
B3 B2 B1 = ¢ c
B3 B2 I Q o a
I B3_ c.t
SLC I B2 I I Z O a
AC �
,iMA I ez I ez I //-�\ SEE PV1B FOR FIRE ACCESS PATHWAYS PV-2 FOR ROOFTOP �. N
NSP
EQUIPMENT CALLOUTS AND ROOF AND ARRAY DIMENSIONS. m o dErt
.' \ TOTAL ROOF AREA: 2,69T.. F�',,,'1)1\
® tc uttl `tires 'c;::ti1m1•t't o
TOTAL MODULE ARL%£: 67'8t }�tOVI y o N
TOTAL ROOF COVERAGE: 24.8 Io
/ Thia rcl r.!'ni:uti:uul..<.pc•,•ilica nns mn+Pin 6.1•]it
I N / BRANCH #OF otTILT IMVtFFi` °nil Ii a tn;;rs ur:till rsa i®
CIRCUIT PANELS 1,�t Sc t..;••.,t lit tier ciiwil;t lot r;imt.
1 12 .,.y5,���, ,..,,••,-, •• icc�k 41 At:lii::A
0
/6" 2 12 1i8;d8cre.1-5.•2'7o-',c cr:1 t re wl»I'le t°r a°. 111
N— — — —mot _It — — - 3 12 ttc 6ci1t5",i 71i" ,, ., & 'o la t
1 .o, ^Ii�p•rC:S Ili.:,w 5
i .1' 59'-2"
DEREK DRIVE - I"N TOTAL#OF
N PANELS 36 PV-1A