Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutSOLR-20-2162 "i N City of Arcadia, CA N ' Permit NO SOLR 20 2162
:4`.4f Development Services Department y .r v t r ti PermltType Solar
,11 240 West Huntington Drive,Post Office Box 60021
a� •-..' Arcadia,CA 91066-6021fi Work Classificatron:Solar Residential.,
(626)574-5416
Permit Status Issu_ d�,
ARCADIA Issue'Date 02/24/2021 I Expiration: 02/24/2022
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
2066 VISTA AVE Arcadia,CA 91006-1546 5765005009
Contacts
MATTHEW WONG&YIK PUI JUEN Owner A C A SOLAR Contractor
2066 VISTA AVE
(626)347-0491 (909)606-8000 952623
' i
Description:ROOF MOUNTED SOLAR SYSTEM 18 Valuation: $ 0.00 vi Tenant
MODULES/OPTIMIZERS AND 1 INVERTER. 200 AMP SERVICE
zt
UPGRADE Total Sq Feet: 0.00 Plan Check# Plan#
'
.sab€iF:.U:dRSLn.A3Jo s4P '.s...,,: �Rt d"'a.r.,e "..„ a l4b +{,•
Fees Amount Payments Amount Paid
Building Plan Check Fee Residential $100.00 Total Fees $324.72
Electrical Permit Issuance Fee $47.01 Cash/Receipt#REC-06855-21 $324.72
Inverters $77.78
Panels $82.45 Amount Due: $0.00
Residential Services up to 400 amps $16.48
Solid Waste Management Fee 2 $1.00
Total: $324.72
6;3 -7i
P
CALLS FOR INSPECTIONS
Svv//n e etc-A-Se Request for inspection by telephone at 626-574-5450. Leave a message
V l l.r<i (, 7✓CJ requesting the address,timeframe and what inspection item is needed.
6,-L4-->1
This permit/plan review expires by time limitation and becomes null and
r I ,Nk i e g. ' 1 void if the work authorized by the permit is not commenced within 180 days
(� Qy� from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 consecutive days.
+ COMPLETED
February 24, 2021
Issued By:Steven Roberts Date
February 25,2021 Page 1 of 1
4�poF�RC9�
v 14 PERMIT/PLAN REVIEW APPLICATION
0.
in Development Services Department,240 West Huntington Drive,Post Office Box 60021
°y0_ Arcadia, CA 91066-6021, (626)574-5416,Fax(626)447-9173
City of
Arcadia
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers'
License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the
Signature of Contractor performance of the work for which this permit is issued.
OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section
❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are:
Code.Any city or county which requires a permit to construct,alter,improve, Carrier
demolish,or repair any structure,prior to its issuance,also required the applicant
for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less)
7000)of Division 3 of the Business and Professions Code)or that he or she is that in the performance of the work for which this permit is issued,I shall
exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions of Section 3700 of the Labor Code,I shall
❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions.
compensation,will do the work,and the structure is not intended or offered for
sale(Section 7044,Business and Professions Code:The Contractors License Date Signature
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
Date Signature Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for
further information.
Name Title
PRINT NAME
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the above-mentioned property for inspection purposes.
Signature Date
t ; ,, � PERMIT/PLAN REVIEW APPLICATION
'µ t:, Development Services Department, 240 West Huntington Drive, Post Office Box 60021.
`i';$(I Arcadia, CA 91066-6021, (626)'574-5416, Fax (626) 447-9173
_� "---\�� 1 ONLINE PERMIT/PLAN REVIEW APPLICATION • . .
. ciTY.or •• .
• . ARCADIA •
Job.Site Address: •
. .LICENSED CONTRACTOR'S DECLARATION. WORKERS'COMPENSATION DECLARATION
El I hereby•affirm under penalty of perjury that 1,am licensed under provisions of I hereby affirm;under.penalty of perjury one of the following: .
:. • Chapter 9-(commencing with Section 7000,of Division 3 of the Business and
Professions Code,and my license is in-full force and effect: 0 I have and will maintain a.certificate of consent to self-insure for workers'
License Class C10 License No.'952623 Exp. •Date 9/30/2022 compensation,',as provided for-by Section 3700•of the,Labor Cade, for the
•
�� perforinanc of the' for.which this permit is issued...
Signature of Contractor ''` ... . a. i'daelialIi/l
OWNER=BUILDER-DECLARATION El I have and.will maintain workers'compensation insurance,as•required by Section
0 I hereby affirm under penalty'of perjury Matl am exempt from the Contractors 3700 of the.Labor Code::for the performance of the work for whic•h this permit
License Law for the following reason• (Section 7031.5, Business and Professions•_ is issued.My workers'compensation insurance carrier and policy numbers are: .
.Code.Any city or county.which requresi •a permit to construct;alter, improve; Carrier
demolish,or repairany structure,prior to its issuance,also required the applicant
for such permit to file a signed statement that he or:she is licensed pursuant to the. Policy Number
(This
provisions of the Contractors License Law(Chapter 9.(commencing with Section ;section need'not be completed if the permit.is for one hundred dollars or less)
7000).of Division 3 of the Business and'Professions Code) or that he or she is • - • •. •
exempt there.from and the basis for the alleged exemption. Any.violation of ❑X I certify t•hat in the performance of:the work for whic•h_this permit is issued,7.shall •
• Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty•of not more than five hundred dollars($500)): compensation Laws of California;and.agree that if I.should become subject to the.
- : . workers'compensation.provisions of Section.3700'of the Labor Code.I shall
' DI, as'owner of the'property, or My employees with wages as their sole forthwith comply will Those.provisions.
• • compensation;will do the work,and the structure is not intended or offered for 2/26/2021. • DQ,j�I;��CheV�il
sale(Section 7044; Business and Professions Code:The Contractors License Date Signature
Law does not a l to an owner of ro ert who builds or irn roves thereon,
PPY .. P P Y P . .
. or,who does.such work himself or•herself:or through his or her own -
employees, provided that such,improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
Sale.If,however,the building or improvement is sold within lone(1)year of and shall-subject an employer to criminal:penalties and civil fines.up to one .
completion;the owner-builder will have.the burden of proving that he or she - hundred:thousand dollars($100,000),in addition to'the cost of compensation,
:. did not build or improve for the purpose of sale). damages as provided:for in.Section 3706 of'the labor Code, interest; and -
attomey's fees. . . :
El 1, as owner of the property, am exclusively contracting-with licensed -
.contractors to,construct the.project.(Section 7044,Business and"Professions _- . ' ' '
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY: .
•who-builds or improves thereon,and who contracts.for such-projects with a i hereby affirm under penalty of perjury that there is a construction lending agency
'contractor(s)licensed:pursuant to the Contractors License Law).: for the.performance-of the work-for which this permit is issued (Section 3097,
.
Civil Code): . . .
ElI.am exempt under'Section 7044;Business and Professions Code,for this reason: • . .
Lender's Name • • • • . -
Date . . ••' Signature " Lender's Address, . . .
IMPORTANT: APPLICATION IS HEREBY MADE.TO THE BUILDING OFFICIAL;.I OR A PERMIT SUBJECT TO THE CONDITIONS AND
• RESTRICTIONS SET FORTH ON THIS APPLiCATiONAND THE FOLLOWING: : .
-I. The City's approved plans:and permit inspection card must remain on the job site,for use by.City inspection personnel.
•
.2. Final.inspection of the work authorized by this permit is required.A_Certificate of Occupancy must be.obtained prior to use and occupancy of new buildings '
. and structures. . .. . . . -
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that"results in the removal,stripping,or altering .
' • of asbestos-containing materials requires an asbestos survey and removal prior td disturbing the asbestos. Please contact AQMD at(909)396=2000 for
further information. •
•
Name . Title
PRINT NAME _ _ . . .
I certify that I have read this.application and state that the above.information is correct'awl that I am the owner or duly authorized agent of:the owner
I agree to comply .with all City ordinances and State Laws relating to building construction. I hereby authorize.representatives of.the City of
Arcadia to enter.upon the above--mentioned property for inspection purposes,
Pavia Cherr •
Signature - �,- Date 2/26/2021. . '
P L AC DISCO NECTiDISCONNECT 140(f PL
DEN0
MET )� ,EnScope of Work: Install 6.12 kW PV solar
Proposed new main panel system with 18 pcs Q-Cells 340W panels
is in the same location as
existiong panel. and one 5.0 kW SolarEdge inverter.
Main Service Panel upgrade from
DRIVE WAY 100A to 200A _
25-2• ROOF ACCESS POINT
CURRENT CODE:
2019 Califomla Building Code/2018 IBC
VENT LOT#:21 . .2019 California Residential Code/2018 IRC
1. o ° TRACT#:18702 2019 California Electreical Code/2017 NEC
o
a + + +.
N 2019 California Mechanical Code/2018 UMC
f PARCEL#:5765-005-009 2019 California Plumbing Code/2018 UPC
Oi ,', , 2019 CFC/2018 IFC
° 2019 CEBC/2018 IEBC
r 0 STRINOn O -R324.8.1 PatInvays.(CFC e05.11.1.21) 2019 Building Energy Efficiency Standards
Not less than two minimum 36-incEwide(914
D ©BTRINO.z + mm)Pathways on separate roof planes '
m �—' •'•.•� 1oe-a' PLAN PREPARED BY:
ACA SOLAR INC.
F13not lens •
than a 38-Inch(914 •
mm)dear set back b
rmqulred on both sides oft + o N 15370-A FAIRFIELD RANCH ROAD
hortrontal ridge. • ' 1 Y CHINO HILLS,CA 91709
+.. o
c,.. •• •• TEL:909-606-8000
O
I
ROUTING ACTIO �- �"NB Y�
Data a►td �p� ' o�'S" 'See
CHIMN Inr alb :•4' �� �c0 QQ4` Sheet# al CS"(1
r Notes
� CIP�5 �o� fib? 4 I
"�L Planning 4 124I (zo O G$ . t / '� �OZo •
v � r
euildim ` 12 a Sp . 'k .Y�► A i edion �� �__Taato N
Fire ?Ali J 6DG 1 r
PWS Wato N
WELO _
PL Trees PL
O - I -
MAIN •
AC
p1!,SEL ARRAY PANEL DIS ONNECT ALL EXPOSED CONDUIT AND Matthew Wong
/�"� I RTER MECHANICAL EQUIPMENT SHALL BE
• PAINTED TO MATCH ROOF AND 6.12 kW DC PV SOLAR
1 o ■ II WALLS. SITE PLAN
I D 2066 Vista Ave
DISCONNECT Arcadia, CA 91006
Drawn eY: Checked 9r Scab: Sheet
SOUTH PANEL ELEVATION K.CHERN D.CHERN NONE 01
. INTERACTIVE SYSTEM Date: RM.bn L.ret flowing Nunben
22 DEC 2020 R NONE