Loading...
HomeMy WebLinkAboutSOLR-21-1072 (:: permit No.SOLR 21 10.72. �'' City of Arcadia, CA b Development Services Department °I r , f�' ,:--,- .,-`.'- +' L Perm,'tType Solar ° 240 West Huntington Drive,Post Office Box 60021 ( :- )3 ' f ' i l' i. ` I � ry" ;A:-`i Arcadia,CA 91066-6021 I j. I I. ? Lp , work Clas ,cation,Solar Redder, I 1 (626)574-5416 : ` Permit Status Issued: I � " _ e. -_ems r .._�:. .•." ,_., ARCADI IssueDate 06/14/2021 j Expiration: 06/14/2022 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 16 W LEMON AVE ' Arcadia,CA 91007-8027 5782022036 Contacts TAO LI Owner FREEDOM FOREVER LLC* Contractor 16 W Lemon AVE 3322 GARFIELD AVE,COMMERCE,CA 90040 (626)594-5953 (213)908-8229 1029644 :l .. . .: � �ti_._.•...,.. - e ,. , . �:,�,.._. _'S... ,vim, Description:ROOF MOUNTED SOLAR SYSTEM 20 MODULES Valuation: $ 0.00 Tenant E AND 1 INVERTER Total Sq Feet: 0.00 Plan Check# Plan# ' Fees Amount Payments Amount Paid Building Plan Check Fee Residential $100.00 Total Fees $308.24 Electrical Permit Issuance Fee $47.01 Cash/Receipt#REC-07908-21 $308.24 Inverters $77.78 Panels $82.45 Amount Due: $0.00 Solid Waste Management Fee 2 $1.00 Total: $308.24.. CALLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. ii1 CO1PtETE G`��L� This permit/plan review expires by time limitation and becomes null and �i-2di-� void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 1c?c! wco 0-0f...Kes P,62 f b0e- AL003011;04 ukirnsecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. June 14, 2021 Issued By: Henry Kemick Date June 14,2021 • Page 1 of 1 4 OFF wv,,,q, _ 9 PERMIT/PLAN REVIEW APPLICATION -.i,11M a Development Services Department,240 West Huntington Drive,Post Office Box 60021 oA%Unity.'No�9 Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of IdLICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions C e,and m�Y license is in full force and effect. �J, 0 I have and will maintain a certificate of consent to self-insure for workers' License Class "C 4V icense No. l0 ZS�7 ' l Exp. Date J,/ 71 compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor ® performance of the work for which this permit is issued. _ OWNER-BUILD R DECLA�TION I have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My wo ers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier a- cAD'^oO IC7 ��Q- demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number r W G z!fv 6,..p Q for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000) of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 00 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date Z Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon, and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for tii furthe information. IP— ame d AI � o hf 1 itlefegAr / CooK0/ i ro/ILPRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply . all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arca 'a to enter up the above-mentioned property for inspection purposes. Sign tore --...„ (° ' ate //7/ / I ) [' l / ) o ) V GPL! '41,6> 4. AFFQDAVIT SELF-CERTIFICATION FOR COMPLIANCE OF SMOKE ALARMS AND CARBON MONOXIDE ALARMS Property Address: (,�? � oK 1� Rc, is �- 9/0 7 Permit Number: SOL(z- Z — j o 7� 10 Brief Job.Description: 5a/�� proe/s i ic%f//rnorn Cc Cabvr2. ow frhutfriss Number of smoke alarms installed: Number of carbon monoxide alarms installed: When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created, Smoke alarms shall be installed in each sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2016 California Residential Code (CRC) and California Health and Safety Code Section 13113.7. For dwellings or sleeping units containing fuel burning appliances or having attached garages, carbon monoxide alarms shall be installed outside each separate sleeping area in the immediate vicinity of the. bedrooms, and on each additional story of the dwelling, including basements as required by Section R315 of the of the. 2016 California Residential Code (CRC). . Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used. All alarms shall comply with requirements for listing and approval by the Office of the State Fire Marshal. http://osfm.fire.ca.qov/licensinalistings/licenselisting brill searchcotest.php As owner of the above referenced property, I hereby certify that the smoke alarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance with the code sections referenced above: I declare under penalty of perjury that the for going is true and correct, and that this . . 2�. W decleati•e� was executed ;n Gate) 6 i'� at Arcadia, California. Owner's Name (printed/typed): -Tao Ls . . Sigry Lure of Owner: 76- . Li This affidavit must be returned to the City of Arcadia inspector prior to final inspection S E AL F't di �N XIDE C/4T O Guest Room m . R1threo Storage • Family Room Garage FIRST FLOOR PLAN `_ SMOKE ALARM I CARBON MONOXIDE ALARM rikt W Master Bedroom Dining Room Kitchen Batty rt q - Close1 Imo. ... closet Closet. FIIIIUly Room - -.- 7C", 1. SECOND FLOOR PLAN `.SMOKE ALARM I al CARBON MONOXIDE ALARM R324.6.1 PATHWAYS: W LEMON AVE THESE DRAWINGS ARE SUBJECT TO NOT LESS THAN TWO MINIMUM 36-INCH WOE PATHWAYS ON COPYRIGHT PROTECTION BY US LAW. SEPARATE ROOF PLANES, REPRODUCTION IN ANY FORM IS FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON I 95�_1�� I EXPRESSLY FORBIDDEN WITHOUT PRIOR ALL BUILDINGS. WRITTEN APPROVAL FROM CURRENT AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET • ' RENEWABLES ENGINEERING INC. OR DRIVEWAY SIOE OF THE ROOF. , FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A :. MINIMUM 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE , Current U� OR STRADDLINGSAMELLANDOVER SCAPF ReneWables OR PLANES.PATHWAYS TH SHALL OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF.PATHWAYS I n I Engineering SHALL BE LOCATED IN AREAS WTH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR MECHANICAL EQUIPMENT. I 45'-6" I •. . CURRENT RENEWABLES R324.62 SETBACK AT RIDGE: A•.DRIVEWAY• ENGINEERING INC. FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 1560CHICAGOAVE,STE.015 • I RIVERSIDE,CA 525D1. PERCENT16IOCTHEPLAN VIEW IS REQUIRED ON BOTH LESS THANF , (N) AN 1B INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A PHONE:(Asp-S0S1T. HORIZONTAL RIDGE. FIRE ACCESS PATHWAY NNVNCRENG.CO FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 I I PERCENT OF THE PLAN VIEW TOTAL ROOF AREANOT LESS THAN I ; (E)FENCE/WALL WITH GATE A 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A 27,�„ - --''el HORIZONTAL RIDGE. ,,, AND MO EMERGENCY ESCAPE AND RESCUE OPENING:PANELS i A�,,, •/`• 'I R3O MODULES INSTALLEDY ON DWELLINGS SHALL NOT BE - :yip'' — (E)MAIN SERVICE PANEL PLACED THE PORTION OF A ROOF THAT IS BELOW AN (— ;y;«'� EMERGENCY ESCAPE AND RESCUE OPENING.A 3E-INCH-WOE I '." PATHWAY SHALL BE PROVIDED TO THE EMERGENCY ESCAPE :s" AND RESCUE OPENING, (E)FENCE/WALL WITH GATE Ii ,.,,` o 11. —(N)UTILITY AC DISCONNECT .� (N)INVERTER:SE6000H-USGRM[SI1] 1 li A -PATHWAY STREET A ► i:3#` D D D i1 OR DRIVEWAY SIDE OF ROOF 1, ,- ;':. B -FIRE ACCESS POINT : Q 36"ACCESS PATHWAYSG%jii L/ 1 \ ..;:> •YN` G •o ❑ i 18"ACCESS PATHWAYS ": •:-. ..; it I; �' _ 'I CONTRACTOR INFO v II /�"''.. '.al N I o NOTES: ( freedom 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED ON (N)SOLAR PV ARRAY I� it N •\� p reedom ACTUAL SITE CONDITION AND MEASUREMENTS. (20)LONGI SOLAR LR4-60HPH-365M 365W I U •°..... 2. CONDUIT SHALL BE PAINTED TO MACH EXTERIOR II it WALL. II ii FREEDOM c FOORE ER,LLC 43445 rOLEOA.,n Orw PARK 1t I! f lI STATE OF wn OYE ED ",B-GEN I' CON R, ER,M_ROI , -SOLAR I.e. li I I Solar Individual k 1 —� II PROPERTY LINE Permit Package POOL I: l,4` f \ II TAO LI I! i/// \ 11'-5"-! 7.300KW Grid Tied li ll Photovoltaic System 16 W LEMON AVE, Ii I� ARCADIA,CA 91007 Ii I) Red DOeaipli"n Dab ,, 48,-6, 1 A INITIAL DESIGN 5252021 II 11 OPPORTUNITY TAO LI PROJECT WA CI !Z : o ATE 6/2021 I - __—.._.—:.--------.. �I /.� SITE PLAN 95'-1" • Y dill Current Renewables Engineering 6/4/2021 Freedom Forever LLC 43445 Business Park Dr Suite 110 Temecula, CA 92590 Attn.:To Whom It May Concern re job: TAO LI 16 W LEMON AVE, ARCADIA, CA 91007 The following calculations are for the structural engineering design of the photovoltaic panels and are valid only for the structural info referenced in the stamped plan set.The verification of such info is the responsibility of others. After review, I certify that the roof structure has sufficient structural capacity for the applied PV loads. All mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Design Criteria: Code: 2019 CBC ASCE 7-16 Live Load: 20 psf Ult Wind Speed: 110 mph Exposure Cat: C Ground Snow: 0 psf Min Roof Snow: NA vitOESSIck, 'SNOT q, w C82118y Current Renewables Engineering Inc. * - �'# Professional Engineer %� OM �r info@currentrenewableseng.com , OF CAL* Exp. 03/31120ZZ 1960 Chicago Ave,Suite D15,Riverside,CA 92507 www.currentrenewableseng.com I 951.254.5655 INTEGRITY I PROFESSIONALISM I CUSTOMER EXPERIENCE Date :6/4/2021 Current Job Code:TAO LI 'F~} Renewables 2 of 6 Engineering Roof Properties: Roof 1 Roof Type= Tile Roof Pitch (deg)= 27 Mean Roof Height(ft) = 13 Attachment Trib Width (ft)= 2.75 Attachment Spacing(ft)= 6 Framing Type= Rafter Framing Size= 2x8 Framing OC Spacing(in.)= 24 Section Thickness, b(in.)= 1.5 Section Depth, d (in.)= 7.25 Section Modulus,Sx(in.^3) = 13.1 Moment of Inertia, lx(in.^4) = 47.6 Framing Span (ft) = 13 Deflection Limit D+L(in.)= 2.6 Deflection Limit S or W (in.)= 1.73 Attachments Pattern = Fully Staggered Framing Upgrade= Adequate Sister Size= NA Wood Species= DF#2 Wood Fb (psi)= 900 Wood Fv(psi) = 180 Wood E (psi) = 1600000 CD(Wind)= 1.6 CD(Snow)= 1.15 C�= 1.15 CM=Ct=CL=C;= 1.0 CF= 1.2 Cfu= 1.00 C�= 1.15 F'b_wind (psi)= 2285 F'b_snow(psi) = 1643 F'v_wind (psi)= 288 F'v_snow(psi) = 207 M_allowable_wind (lb-ft)= 2503 M_allowable_snow(lb-ft) = 1799 V_allowable_wind (lbs)= 2088 V_allowable_snow (Ibs)= 1501 E' (psi)= 1600000 1960 Chicago Ave,Suite D15,Riverside,CA 92507 www.currentrenewableseng.com I 951.254.5655 INTEGRITY I PROFESSIONALISM I CUSTOMER EXPERIENCE F Date :6/4/2021 Current Job Code:TAO LI 3of6 Renewables - - . Engineering Load Calculation: Dead Load Calculations: Panels Dead Load (psf)= 3.0 Roof 1 Roofing Weight(psf)= 9.0 Decking Weight(psf)= 2.0 Framing Weight(psf)= 1.2 Misc.Additional Weight(psf)= 1.0 Existing Dead Load (psf)= 13.2 Total Dead Load (psf)= 16.2 Wind Load Calculations: Ultimate Wind Speed (mph) = 110 Directionality Factor, kd = 0.85 Topographic Factor, kzt= 1.0 Roof 1 Velocity Press Exp Factor, kz= 0.85 Ground Elevation Factor, ke= 1.00 Velocity Pressure, qz(psf)= 22.4 Array Edge Factor,yE= 1.25 Solar Equalization Factor,ya = 0.64 External Pressure Up, GCp_1= -1.5 External Pressure Up, GCp_2= -2.2 External Pressure Up, GCp_3= -2.3 External Pressure Down,GCp= 0.6 Design Pressure Up, p_i (psf)= -27.0 Design Pressure Up, p_2 (psf) _ -39.6 Design Pressure Up, p_3 (psf) = -41.4 Design Pressure Down, p (psf)= 16.0 Hardware Checks: Lag Screw Checks: Roof 1 Ref.Widthrawal Value,W(lb/in)= 266 (Cm= Ct=Ceg= 1.0) CD= 1.6 Adjusted Widthrawal Value,W' (lb/in)= 426 Lag Penetration, p (in.) = 2.5 Allowable Widthrawal Force,W'p (Ibs) = 1064 1960 Chicago Ave,Suite D15, Riverside,CA 92507 www.currentrenewableseng.com I 951.254.5655 INTEGRITY I PROFESSIONALISM I CUSTOMER EXPERIENCE Date :6/4/2021 5: Current Job Code:TAO LI Renewables 4 of 6 Engineering Applied Uplift Force (Ibs)= -444 Uplift DCR= 0.42 Ref. Lateral Value,Z(Ibs) = 270 (Cm= Ct=Co=Ceg= 1.0) Co= 0.9 Adjusted Lateral Value,Z' (Ibs) = 243 Applied Laeral Force(Ibs) = 22 Angle of Resultant Force, a(deg) = 87 djusted Interaction Lateral Value,Zia(Ibs)= 1055 Lateral DCR= 0.02 Roof Framing Checks: Force Checks: Roof 1 LC1: D+S Applied Moment(lb-ft)= 686 Applied Shear(Ibs) = 211 Allowable Moment(lb-ft) = 1799 Allowable Shear(Ibs) = 1501 Moment DCR= 0.38 Shear DCR= 0.14 LC2: D+0.6W Applied Moment(lb-ft)= 1092 Applied Shear(Ibs) = 336 Allowable Moment(lb-ft) = 2503 Allowable Shear(Ibs)= 2088 Moment DCR= 0.44 Shear DCR= 0.16 LC3: D+0.75(5+0.6W) Applied Moment(lb-ft)= 991 Applied Shear(Ibs) = 305 Allowable Moment(lb-ft)= 2503 Allowable Shear(Ibs) = 2088 Moment DCR= 0.40 Shear DCR= 0.15 LC4:0.6D+0.6W Applied Moment(lb-ft)= 273 Applied Shear(Ibs) = 84 Allowable Moment(lb-ft) = 2503 Allowable Shear(Ibs)= 2088 Moment DCR= 0.11 1960 Chicago Ave,Suite D15,Riverside,CA 92507 www.currentrenewableseng.com I 951.254.5655 INTEGRITY I PROFESSIONALISM I CUSTOMER EXPERIENCE /-� Date :6/4/2021 Current -� Job Code:TAO LI ', \i Renewables 5 of 6 Engineering Shear DCR= 0.04 Deflection Checks(Service Level): Roof 1 LC1: D+L Deflection (in.) = 0.41 Deflection Limit(in.) = 2.99 Deflection DCR= 0.14 LC2: S Deflection (in.)= 0.00 Deflection Limit(in.)= 1.99 Deflection DCR= 0.00 LC3:W(Down) Deflection (in.)= 0.11 Deflection Limit(in.)= 1.99 Deflection DCR= 0.06 LC4:W(Up) Deflection (in.)= -0.19 Deflection Limit(in.)= 1.99 Deflection DCR= 0.10 Seismic Check: Existing Weight: Wall Weight(psf) = 17 Tributary Wall Area (ft2) = 1200 Total Wall Weight(Ibs)= 20400 Roof Weight(psf) = 13 Roof Area (ft2)= 3500 Total Roof Weight(Ibs) = 46361 Total Existing Weight(Ibs)= 66761 Additional PV Weight: PV Panel Weight(Ibs)= 54 Number of Panels= 20 Total Additional PV Weight(Ibs)= 1089 Weight Increase: (Existing W+Additional W)/(Existing W) = 102% The increase in weight as a result of the solar system is less than 10%of the existing structure and 1960 Chicago Ave,Suite D15,Riverside,CA 92507 www.currentrenewableseng.com I 951.254.5655 INTEGRITY I PROFESSIONALISM I CUSTOMER EXPERIENCE Date :6/4/2021 Current Job Code:TAO LI ��✓ Renewables 6 of 6 Engineering therefore no further seismic analysis is required. Limits of Scope of Work and Liability: Existing structure is assumed to have been designed and constructed following appropriate codes at time of erection, and assumed to have appropriate permits.The calculations produced are only for the roof framing supporting the proposed PV installation referenced in the stamped planset and were completed according to generally recognized structural analysis standards and procedures, professional engineering and design experience, opinions and judgements. Existing deficiencies which are unknown or were not observable during time of inspection are not included in this scope of work.All PV modules, racking, and mounting equipment shall be designed and installed per manufacturer's approved installation specifications.The Engineer of Record and the engineering consulting firm assume no responsibility for misuse or improper installation.This analysis is not stamped for water leakage. Framing was determined based on information in provided plans and/or photos, along with engineering judgement. Prior to commencement of work,the contractor shall verify the framing sizes,spacings, and spans noted in the stamped plans, calculations, and cert letter(where applicable) and notify the Engineer of Record of any discrepancies prior to starting construction. Contractor shall also verify that there is no damaged framing that was not addressed in stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any concerns prior to starting construction. 1960 Chicago Ave,Suite D15,Riverside,CA 92507 www.currentrenewableseng.com I 951.254.5655 INTEGRITY I PROFESSIONALISM I CUSTOMER EXPERIENCE