Loading...
HomeMy WebLinkAboutSOLR-21-1090 4 . m� °�� lPerm,tINO SOLR 21 1090 City of Arcadia, CA .' ;au o 1 '� , �s nd� �, � �€ �� Development Services Department „ x� ii > �fai ' j e, Perrr�It Type Olar 1 240 West Huntington Drive,Post Office Box 60021 A. i d r`1 1 g $" ' ,,� I Workclassfficat,on Solar Residential,; te ; Arcadia,CA 91066-6021 _ , ' s ` y 7,0 (626)574-5416 , 0 a 1 ova ," 4R Permit Status pHIssued, ARCADIA IssueDKa e O6/15/2021 Expiration: 06/15/2022 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 2506 S SECOND AVE Arcadia,CA 91006-5207 5790027023 issmavaymammarainaramma, ��:d-� � Contacts ZHENG,CURTIS W AND GAO,YUN XUAN Owner FREEVOLT U S A INC* Contractor 2001 SANTA ANITA AVE STE 203A,SOUTH EL MONTE,CA 91733-3441 42005 COOK ST 310, PALM DESERT,CA 92211 (760)345-0080 1029455 Description:ROOF MOUNTED SOLAR SYSTEM 20 Valuation: $ 0.00 1 Tenant MODULES/OPTIMIZERS AND 1INVERTER Total Sq Feet: 0.00 Plan Check# Plan# Fees Amount payments Amount Paid Building Plan Check Fee Residential $100.00 Total Fees $324.72 Distribution Panel • $16.48 Cash/Receipt#REC-07933-21 $324.72 Electrical Permit Issuance Fee $47.01 Amount Due: $0.00 Inverters $77.78 Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $324.72 6-2-1 -2 CALLS FOR INSPECTIONS r Request for inspection by telephone at 626-574-5450. Leave a message N � ai4 b'\\ requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. IS t t Q1 11111 June 15, 2021 Issued By:Jeff Wang Date June 15,2021 Page l of I. 17 PERMIT/PLAN REVIEW APPLICATION .4 Development Services Department,240 West Huntington Drive,Post Office Box 60021 Y% Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Cod ,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self insure for workers' License Class (0 Licens oo. Signature of Contractor I 0 et 4 7-6 /Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the � performance of the work for which this permit is issued. OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier A-' -r),--- demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number for such permit to file a signed statement that he or she is licensed pursuant to the (This section need not be completed if the permit is for one hundred dollars or less) provisions of the Contractors License Law(Chapter 9(commencing with Section 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.E by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for rate C-' 1 q Sici2.------- gnature sale(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions i Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon, and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. y 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. ame e)-- I Z( Title PRINT NAME 1 I certify that I have read this application and state that the above information is rect and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes.S natureCC 1 ate 6 14 f I W CONS MING Wyssling Consulting 76 North Meadowbrook Drive Alpine, UT 84004 Scott E. Wyssling, PE, PP, CME office (201) 874-3483 swyssling@wysslingconsulting.corn June 3,2021 FreeVolt USA, Inc 42005 Cook Street, Unit 310 Palm Desert, CA 92211 Re: Engineering Services Zheng Residence 2506 S 2nd Avenue,Arcadia, CA 6.000 kW System Size Dear Mr. Parker: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site VisitNerification Form prepared by a FreeVolt representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by FreeVolt and will be utilized for approval and construction of the proposed system. 3. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of truss system with all chords constructed of 2 x 4 dimensional lumber at 24" on center. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Doug-Fir#2 or better with standard construction components.The existing roofing material consists of tile shingles. Photos of the dwelling also indicate that there is a permanent foundation. A. Loading Criteria Used • 110 MPH wind loading based on ASCE 7-16 Exposure Category"B"at a slope of 26 degrees • 7 PSF= Dead Load roofing/framing Live Load=20 PSF/0 PSF (where panels are installed) • 3 PSF= Dead Load solar panels/mounting hardware Total Dead Load=10 PSF The above values are within acceptable limits of recognized industry standards for similar structures in accordance with the E201 California Building Code. Analysis performed of the existing roof structure utilizing the 6-ove-loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. • Page 2 of 2 B. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Quickbolt Installation Manual', which can be found on the Ironridge website (http://ironridge.com/). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 lbs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Doug-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of,2v141;:is..less than what is allowable per connection and therefore is adequate. Based on the variable factorsfor the existing roof framing and installation tolerances,-usmgra-thread-depth,of"2-'/z"wit minimum size of 5/16—lag-screw-per-attachmerit point for panel anchor mounts_should=beeadequate-with a sufficient factor_.of safety --d 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed no greater than 72"o/c. 4. Panel supports connections shall be staggered to distribute load to adjacent trusses. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the 2019 California Building Code, current industry and standards, and based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. V truly youeo , - Scott E.Wyssli,:, PE California License N, :.4 eepOFES,q,ks s. "1 e, • c : ... srq, iv_t WCONSULTING4 DocuSign Envelope ID:18671 D83-58EE-48C6-A68E-8005380F6F82 �, .V*/ t� t A.Ivi3�1.1 + ,t,ti.1,;5.0is, AFFIDAVIT SELF-CERTIFICATION FOR COMPLIANCE OF SMOKE ALARMS AND CARBON MONOXIDE ALARMS Property Address: 2506 S 2nd Ave arcadi a,Ca 91006 Permit Number: SOLR-21-1090 Brief Job DescriptionRooF MOUNTSOLAR SYSTEM 20 MODULES/OPTIMIZERS AND 1 INVERTER Number of smoke alarms installed: 6 Number of carbon monoxide alarms installed: 3 When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created, Smoke alarms shall be installed in each sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2013 California Residential Code (CRC) and California Health and Safety Code Section 13113.7. For dwellings or sleeping units containing fuel burning appliances or having attached garages, carbon monoxide alarms shall be installed outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements as required by Section R315 of the of the 2010 California Residential Code (CRC). Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used. All alarms shall comply with requirements for listing and approval by the Office of the State Fire Marshall. http://osfm.fire.ca.qov/licensinglistings/licenselistinq bml searchcotest.php As owner of the above referenced property, I hereby certify that the smoke alarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance with the code sections referenced above. I declare under penalty of perjury that the foregoing is true and correct, and that this declaration was executed on Date gun 13th ( ) at Arcadia, California. Curtis Zheng Owner's Name (printed/typed): 000us/ysIyrtu d b Signature of Owner: r AESFAO2F42364AF... This affidavit must be returned to the City of Arcadia inspector prior to final inspection . PROJECT DESCRIPTION: 20 A Q x REEVOLT PV-GRAF 60M6 300W PV MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES \ o o j DC SYSTEM SIZE:6.000kW DC I— n G F F m AC SYSTEM SIZE:5.413kW CEC-AC �,II \ Q Z o . c _-� EQUIPMENT SUMMARY = rn v 20 FREEVOLTPV-GRAF-60M6300W MONO MODULES 1 6 g 20 SOLAREDGE P320 POWER OPTIMIZERS (E)TREES — o 00 w 01 SOLAREDGE:SE5000H-US(240V)INVERTER c o ROOF ARRAY AREA#1:-246.54 SQ FT. ROOF#2 — ROOF ARRAY AREA#2:-105.66 SQ FT. (6)FREEVOLM PV-GRAF-60M6-WITH u_ N M MONO MODULES WITH v SOLAREDGE:P320 OPTIMIZERS D. 192.01 r 1 PROPERTY LINE REVISIONS ---�- '--- — — —a —s—a— -� DESCRIPTION DATE REV r ----------------------------a--a--- — - ) w . C. �)' I° 2C '`EXISTING \ )i--i_ ,. / m DRIVEWAY °I z 0 j 7 m ���� -� _ ° 1 �� 2-STORYX I (E)POOL I ) / HOUSE v I J )) / I_A DATE:06/03/2021 f x. �) I O PROJECT NAME&ADDRESS m b I / 0--'� ,Y - — °I �Y�(� `J Z� (E)CHIMNEY(TYP.) i `( o �� j Z W W o �I W U >� I -�O ... ,. RI = Z oa �;J w.�.l i 0 N V w 1 //f-: o; CD g (, "�� I W w o a0 1 -)-)9 ( (, -- ---- PROPERTY LINE �� �Ji�J 193.0 (E)FENCE — \� — (E)UTILITY METER/MAIN COMBO . DRAWN BY — (E)GATE _ — ROOF#1 1/ ESR (TYP.) (14)FREEVOLT PVGRAF-60M6300W / lS� MONO MODULES WITH �, F SHEET NAME SOLAREDGE:P320 OPTIMIZERS /" �',, PLOT PLAN WITH ce3s ROOF PLAN t SHEET SIZE ANSI B PEFCO 11"X 17" 1 I PLOT PLAN WITH ROOF PLAN SHEET NUMBER PV-3 ,SCALE:1/16'=1'-0' PV-3