HomeMy WebLinkAboutSOLR-21-1113 •
•
City of Arcadia, CA Permit NO SOLR 21 1113 3
Development Services Department
3 "�✓' I ; � Permit Type:Solar a.
240 West Huntington Drive,Post Office Box 60021
I s, j Work Classification:Solar Residential.
Arcadia,CA 91066-6021 {_'
(626)574-5416
r' Permrtstatus Issued�r;
ARCADIA Issue bate:06/29/2021 Expiration: 06/29/2022
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
1201 VALENCIA WAY Arcadia,CA 91006-2407 5771029016
Contacts
•
_ _ 4
KEVIN SZE CHUN Owner TESLA ENERGY* Contractor
1201 VALENCIA 3055 Clearview Way,San Mateo,CA 94402
(609)240-5637 (323)240-3174 888104
Description:ROOF MOUNTED SOLAR SYSTEM 12 MODULES, 1 Valuation: $ 0.00 4 Tenant
INVERTER
Total Sq Feet: 0.00 „ Plan Check# Plan#
- i s
Fees Amount payments Amount Paid
Building Plan Check Fee Residential $100.00 Total Fees $308.24
Electrical Permit Issuance Fee $47.01 Cash/Receipt#REC-08045-21 $308.24
Inverters $77.78
Panels $82.45 Amount Due: $0.00
Solid Waste Management Fee 2 $1.00
Total: $308.24
CALLS FOR INSPECTIONS
Request for inspection by telephone at 626-574-5450. Leave a message
requesting the address,timeframe and what inspection item is needed.
This permit/plan review expires by time limitation and becomes null and
void if the work authorized by the permit is not commenced within 180 days
from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 consecutive days.
•
15 COMPLETED
June 29,2021
Issued By:Steven Roberts Date
June 29,2021 Page 1 of 1
~A of `4
• '+w PERMIT/PLAN REVIEW APPLICATION
Development Services Department,240 West Huntington Drive,Post Office Box 60021
�0mua„r ore°`O0 Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173
City of
Arcadia
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers'
License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
Signature of Contractor
❑ I have and will maintain workers'compensation insurance,as required by Section
OWNER-BUILDER DECLARATION
❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are:
Code.Any city or county which requires a permit to construct,alter,improve, Carrier
demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number
for such permit to file a signed statement that he or she is licensed pursuant to the (This section need not be completed if the permit is for one hundred dollars or less)
provisions of the Contractors License Law(Chapter 9(commencing with Section
7000)of Division 3 of the Business and Professions Code)or that he or she is
❑ I certify that in the performance of the work for which this permit is issued,I shall
exempt there from and the basis for the alleged exemption. Any violation of
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions of Section 3700 of the Labor Code,I shall
❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions.
compensation,will do the work,and the structure is not intended or offered for
sale(Section 7044,Business and Professions Code:The Contractors License Date Signature
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
Date Signature Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for
further information.
Name Title
PRINT NAME
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the above-mentioned property for inspection purposes.
Signature Date
' t
PITCH:20 ARRAY PITCH:20
ALL ELECTRICAL EQUIPMENT TO BE MP1 AZIMUTH:90 ARRAY AZIMUTH:90
MOUNTED ON WALL MATERIAL:Flat Cement Tile STORY:1 Story
,crcgnpnrc'irf`B':•t ice:()e1);7 t1:)CCI
I3'FSB 'In-:r et Id pl;;;; nr.l=,•,c;rir;n in;'.nmt he kept
on the."(;h al nl!lint;';sod no:•itt 4:. rn•;iitcralirns
o ® r sh;ti he n te.h.e'.:t.W hl the 13riiding,')R(Skin.
T'hc:ita:rlrr.;,,;('Ihr:I
he hell ',hall not
I ui•; •i i� ri L.e ru:,±t j;;I
u;,i .u'.r.ar:n n:ail,e;i:,t;r.in,:i2t.,ir:''ieit i,,,
.,.6.!
a I
a o
/�Fo Front Of House LEGEND
® E.' n (E)UTILITY METER&WARNING LABEL
\<' n INVERTER W/INTEGRATED DC DISCO
AC- f —__—L'-6_'.ES13_——— erlial' I &WARNING LABELS
l - -- I W, I i ri DC DISCONNECT&WARNING LABELS
i 1,2 o / \ 1 IN
O ;Inv', -n 4 T _ I AC DISCONNECT&WARNING LABELS
I
! W 0 �5 MP � s� I ri DC JUNCTION/COMBINER BOX&LABELS
1 i1'6
ri DISTRIBUTION PANEL&LABELS
o J; (iii, ri LOAD CENTER &WARNING LABELS
o ® O DEDICATED PV SYSTEM METER
0
"il n RAPID SHUTDOWN
I 3'FSB RI 0 STANDOFF LOCATIONS CD - CONDUIT RUN ON EXTERIOR
• CONDUIT RUN ON INTERIOR
0 — GATE/FENCE
(E)DRIVEWAY HEAT PRODUCING VENTS ARE RED
•d o. It '1 INTERIOR EQUIPMENT IS DASHED
�gOFESS/pM =�
w4,at ouNr,�y%I� Digitally signed by
W `.z Eugene Munyanziza
C 88783 a, Date:2021.06:07
SITE PLAN
'
J, ii� lk Sole:1/8"=1'
8'
16' W E
f OF CA��EO
O1'
a PNnw-M NTCMA,>a NaM a° JB-9104095 00 °b°"` °� °®°` _
aDEOT C SM.Nor BE USED Pm nE Kevin Shan 4.08 KW PV ARRAY Ricardo Campo T �- L n
mEfIT ff WOE EAgrr 1 zEp Mighty Hook ' 1201 Valencia Way P
WU.IT CC t>anosD N max Cr N
PART To COHERE a19IE ME I 0l 111
o ONIZATat.Eu4PT IN cU UNN WTI MinArcadia, CA 91006
nc SALE MEI USE OF DE R0ECTNE (12)Hanwha Q-(EI I S#Q.Peak DUO BLK-G6+ 340
nsu EQUIPMENT.MEW 1TE w�TIDI NwAa!PERMISSI PALE IOW MET: fHY. DAM
ON°P A"` 3.8 kW Testa Inc 1534000-00-E(240V) 6092405637 SITE PLAN 3 6/5/2021 1°
Version#91.5-1
NAS
June 5,2021
RE: CERTIFICATION LETTER
Project/Job#9104095
Project Address: Shan Residence
1201 Valencia Way 2
Arcadia,CA 91006 A �" O ,1,h ,r4-i)r �1
AHJ Arcadia fir;.".`l(Pj)3i14; " �'
SC Office Atwater Village -.- :;tT<,?a;\' ,;�
ncilt
Design Criteria:
T.iis Seto plans am yi�11:i1111. i1!)iiS 31�USt 1)t]il'])t
Applicable Codes=Structure:2019 CEBC;PV:2019 CBC/CRC,ASCE 7-16,•and 1 r5S1) it Ilai t3,nles lInd no`l`"I'`'I• or,jt!.!.,110 1S
-Risk Category=II ' it +'111<l�il'e':j' 1)t 1)i t1:e a'ili!SC'.+!?!;t•.l!SS(N1.
-Wind Speed=100 mph(3-s Gust-Vult),Exposure Category C,Partially/Fully Enclosied elite od c 1 i,, + `i�i..,tji,l] };�lt] ]ii)t
-Ground/Roof Snow Load=0 psf 1)e Y�,l;jt)a11+�;): 1i1i' j:::!.1 " 't' t)``
-MP1:Roof DL=14 psf,Roof LL=19.5 psf �)e;wit.) tl)])!'1'!)1i1,i)!';i)11,lieu;!1?1)1'S)1 :1 1)1 t1)C 1;O1�ltlt)11
Oi n.., i)m\iNions of ;1!!i cit) ortli11anct.'Ul'.'.ti1[l I;lll
Per Section 1613.1,W-(PV)/W-(exist roof)=3.5%,Increase Seismic Shear Load<10%,->[OK]
To Whom It May Concern,
A structural evaluation of loading was conducted for the above address based on the design criteria listed above.
Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive
compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above.
Additionally,I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the
manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading.
The PV assembly hardware specifications are contained in the plans/docs submitted for approval.
Installer shall verify existing roof framing is in suitable condition and does not exhibit any signs of structural damage which may diminish
the capacity of its members or connections prior to commencement of PV installation.Installer verification of the mounting plane noted
above is required because some or all of the framing was not observed prior to the structural evaluation performed for this report.
Q9, fESS0A,
4440 -11.1 1ygge
* Vi.,, Digitally signed by
W``' G:88783 7, Eugene Mtinyanziza
.o * Date:2021M.06:07
JaQ' 08 5308 04'00' '
F,OF CALL
Tesla,Inc.
- S L II - i. 7 Clk2 tii ..'Way San'P °.iC.CA 8442
Version#91.5-1
NAS
HARDWARE DESIGN AND STRUCTURAL EVALUATION RESULTS SUMMARY TABLES
Landscape ' Hardware--Landscalie MOdules',Standoff Specifications
:Hardware X-X Spacing X-X Cantilever, , Y-Y Spacing Y-Y Cantilever ,- Configuration Uplift DCR
MP1 72" 24" 52" 24" Not-Staggered 68.5%
Portrait Hardware-Portrait Modules Standoff Specifications
Hardware X-X Spacing X-X Cantilever , • Y-Y Spacing Y-Y Cantilever„ Configuration Uplift OCR
MP1 48" 20" 52" 24" Not-Staggered 45.7%
' -- -Roof Pitch ' Qualification Results
Mounting Plane "
(Degrees)- Member Evaluation Results ' '•
MP1 20° Member Impact Check OK
•
•
Tesla,Inc.
5 :3(Th v'thiy. Mat....;,: CA 84.102
600028 028 f Ci50
`
-
112'-1^ �
� c:Tor�mc�cn�
«r,lenon^n*,x/
| mav��' um��n�u*,,wv���
| � ~..�^m:/,: m*�*m�:���»�^u
| | �u �"*« n�v /�x:a«�/~`"=m
| -- The^='n" � �mWuv^rw�v�m-~
| �u*mvrn��/,/~q *m,w
"!'a'
jn
|
/ \
|
| / 2| 6<
| w==~ |�
| l=
. .�
. �
| �
^� L---------- -- '- -- --------�_--_-----_------------- ------- '
| |
� .
� 11411- -- °
PROPERTY PLAN _p
aale:1"~20'-0' n /m\ c
o � IV. ��
n
JB-B'04095 00 ==� �°� =m
Kevin Shan 4.00 NY PV ARRAY Ricardo ~�' �� �� U �~
12O1 0dvodo Way ^ �~ �~ �~ ��
woM ' ' Arcadia, CA 81006
- V2 xaw"o-msL #up"�0000m-«o+ mo =z=m =m =^ Dx
aOMOaAPC --- "at ma"/m1e0o -m+c(x40 5092405037 PROPERTY PLAN 2 6*/20 1
`
^
,