Loading...
HomeMy WebLinkAboutSOLR-21-0195 I ' ',1 Permit NO SOLR 21 0195 0 City of Arcadia, CA [ Development Services Department �`"� v v"w k "� "Permit Type Solar" r } e J ^t 4, 1 i k , ,`,�a + 240 West Huntington Drive,Post Office Box 60021 f i f ' I' I Arcadia,CA 91066-6021 ' ,''C 'work Classification 'Solar Residential.; l- " (626)574-5416 -' , Permit Status Issued;„ A CA_DIA Issue.Date o2/05/2021 1 Expiration: 02/07/2022 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number t. 1038 ENCANTO DR Arcadia,CA 91007-6105 5776007003 — «., .,P‘..,>. 14,..4._ .441,0,,..V.ta. :: ALBERT WU Owner TESLA ENERGY* Contractor 1038 ENCANTO DR 3055 Clearview Way,San Mateo,CA 94402 (626)991-0776 (323)240-3174 888104 Description:ROOF MOUNT PV SYSTEM 24 MODULES/1 1,6, Valuation: $ 0.00 Tenant s.INVERTER Total Sq Feet: 0.00 Plan Check# Plan# ^ 'h •p Fees Amount Payments Amount Paid Building Plan Check Fee Residential $100.00 Total Fees $308.24 Electrical Permit Issuance Fee $47.01 Cash/Receipt#REC-06697-21 $308.24 Inverters $77.78 Panels Amount Due: $0.00 $82.45 Solid Waste Management Fee 2 $1.00 Total: $308.24 7,-/Z/ á1 ? CALLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and • void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. 15i CONIPLTED February 05, 2021 Issued By:John Zurick Date February 08,2021 Page 1 of 1 PERMIT/PLAN REVIEW APPLICATION Development Services Department, 240 West Huntington Drive,Post Office Box 60021 Arcadia, CA 91066-6021, (626) 574-5416, Fax (626) 447-9173 ONLINE PERMIT/PLAN REVIEW APPLICATION crrY OF ARCADIA Job Site Address: 1038 Encanto Dr. LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class c-10 888104 License No. Exp. Date 12/31/21 compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Signature of Contractor OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section ❑I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit is issued.My workers'compensation insurance carrier and policy numbers are: License Law for the following reason(Section 7031.5,Business and Professions Code.Any city or county which requires a permit to construct,alter,improve, Carrier Zurinch American demolish,or repair any structure,prior to its issuance,also required the applicant EWS107458503 for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is 1 certify that in the performance of the work for which this permit is issued,I shall exempt there from and the basis for the alleged exemption. Any violation of El Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California.and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code.I shall ElI, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions compensation,will do the work,and the structure is not intended or offered for 10/31/21 f Ara- y� f, sale(Section 7044, Business and Professions Code:The Contractors License Date Srgnatare Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees, provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Section 7044.Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law), for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date ISrgnature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL, FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPI..ICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for further information. Name Title PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. 1 hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Stgnature 'RK^a ' 7 Date 2/8/21 / \ "\ / �•• ........ ? 4111b1 / let l • pis A'4 * '/ • -c / / / / A.„„, I I PROPERTY PLAN N Scale:1"=30'-0' w V E 0 30' 60' —� S CWIDanUE-71,E IxrvmIATION ""BEM JB-9103893 00 CUSTOMER °�"� °�°� _ =TOED SHALL NOT BE USED FOR THE Christy wu 8.16 KW PV ARRAY Harold Johnson BENEFIT OF NRDNE E%(EPT TESTA INC.,NOR MOWfOO srsIER 1038 En canto D r T E 5 L n PART TSHMI o N MENS SCWSED'E IRENRE0PPEN N rs aR ZEP Mighty Hook OROANZAnON,ECCEPT N aroma MITH MmUs Arcadia, CA 91007 THE SALE AND USE OF THE RESPECTIVE (24)Hanwha Q-CELLS#Q.Peak DUO SU<-G6+ 340 TEEIA EQUIPMENT.MITIiOUT TIE NETTER NVERTER PACE NAIL SKEET: REV. DATE: PEAIOE90N OF TEDA Na Tula#1538000-00-E 6268219666 2 12/29/2020 PROPERTY PLAN Version#88.4-1 ,Q ,` NAS December 29,2020nJ 618tt. rn RE: CERTIFICATION LETTER ^}� / :# Project/Job#9103893 Project Address: Wu Residence 1038 Encanto Dr of Arcadia,CA 91007 "STR ONLY" Abe De .� ����� AHJ Arcadia Vera "'°°"�"ffi°° SC Office Atwater Village Design Criteria: -Applicable Codes=Structure:2019 CEBC;PV:2019 CBC/CRC,ASCE 7-16,and 2018 NDS -Risk Category=II -Wind Speed=100 mph,Exposure Category C,Partially/Fully Enclosed Method -Ground/Roof Snow Load=0 psf -MP1:Roof DL=15.5 psf,Roof LL=19.5 psf -MP2:Roof DL=15.5 psf,Roof LL=20 psf • Per Section 1613.1,W-(PV)/W-(exist roof)=4.3%,Increase Seismic Shear Load<10%,->[OKj To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/dots submitted for approval. Installer shall verify existing roof framing is in suitable condition and does not exhibit any signs of structural damage which may diminish the capacity of its members or connections prior to commencement of PV installation.Installer verification of the mounting planes noted above is required because some or all of the framing was not observed prior to the structural evaluation performed for this report. Sincerely Abe De Vera,PE,SE ., Structural Engineer,"' Phone:888.765.2489,x57526 Email:adevera@tesla.com Tesla,Inc. .s ` L_ 3055';ie'.d7ViY...:'a ay.Sap, '.E i CA 944:;,2 Version#88.4-1 NAS HARDIIVARDE,.'101*-ANpis:TRugToRALEyAt.viynowREwt,,TostimmARYTABLE*1,fAt-g:: Landscape Hardware- Specifications •HardwareX, X-X SpaCin§',. •z•-••X-X Cantilever ' ' - •Configuration -, DCFC:' MP1 72" 24" 52" 24" Not-Staggered 44.3% MP2 72" 24" 52" 24" Not-Staggered 47.2% Portrait Hardware-Portrait Modules Standoff Specifications Hardware Spacing; ••-. X-X cantilever', 'y,Y Spacing Y-Y Cantilever COnfiguration. Uplift DCR MP1 64" 21" 52" 24" Not-Staggered 39.3% MP2 64" 21" 52" 24" Not-Staggered 41.9% Mountin Plane Roof Pitch . Qualification Results • (Degrees),- 7Member Evaluation Results MP1 21° Member Impact Check OK MP2 18° Member Impact Check OK Tesla,Inc. 3055 Ciearviewli1.4y.Si.V)Ma!e.-D.CA 9,1,102 P 650 69$1,k 1028 f 650 638 1029 r e ... _ t tt k AUTHORIZATION TO MARK Total Quality_Assured. This authorizes the application of the Certification Mark(s) shown below to the models described in the Products) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. \ 1 Applicant: Tesla Inc. Manufacturer: Tesla Inc. Address: 3500 Deer Creek Road Address: 1 Electric Avenue Palo Alto, California 94304 Sparks, Nevada 89434 Country: USA Country: USA Contact: Mr. Jonathan McCormick Contact: Mohammed Gilani Mr.Viraj Andrabadu K P Phone: 650-391-7144 Phone: (269)290-4770 650-339-5597 FAX: na FAX: na j m cco rm ick@tes la.com Email: vandrabadukurundu@tesla.com Email: mgilani@tesla.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Cortland, NY-13045 Control Number: 5005998 Authorized by: for L. aft ew' ny.der, Ce it f on Manager • ' (--.11i: '‘.,.. , •• trxrxtG • • .. Intertek ) This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources[UL 1741:2010 Ed.2+R:15Feb2018] Standard(s): Supplement SA to UL 1741 -Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources[UL 1741:2010 Ed.2(Supplement SA)+R:15Feb2018] Photovoltaic(PV) DC Arc-Fault Circuit Protection [UL 1699B:2018 Ed.1] Product: PV inverter Brand Name: Tesla Models: 1538000 followed by-,followed by two numbers, followed by-,followed by one letter; 1534000 followed by-,followed by two numbers, followed by-,followed by one letter; ATM for Report 104200172CRT-001 Page 1 of 1 ATM Issued: 30-Nov-2020 ED 16.3.15(15-Oct-20)Mandatory Ferm�f wo ROOF 21 1104; City of Arcadia, CA � � .^-.. . i a .. i ��-.� �; ) Development Services Department (y z� ( > r € i a' : Permi•t.Type Roof 240 West Huntington Drive,Post Office Box 60021 1� r r} "' °3 ( r 1 T Arcadia,CA 91066-6021 i Work Classification-:Reroof-Residential i, , (626)574-5416 1 RermitStatus:Issued A=':cADIA Issue,Date:06/17/2021 I Expiration: 06/17/2022 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 1038 ENCANTO DR Arcadia,CA 91007-6105 5776007003 Contacts ALBERT WU Owner ABOVE ALL CONSTRUCTION INC* Contractor 1038 ENCANTO DR 3343 DURAHART ST,RIVERSIDE,CA 92507 (626)991-0776 (951)742-7156 933062 Description:REMOVE TILE,REROOF HOUSE WITH MALARKEY Valuation: $ 6,000.00 ' Tenant DESET NOIR CLASS A 19 SQ UNDER SOLAR ARRAY SYSTEM ONLY (EA) Total Sq Feet: 0.00 , Plan Check# Plan# Fees Amount payments I Amount Paid Building Issuing Fee $47.01 Total Fees $223.71 Building Permit Fees $170.45 Cash/Receipt#REC-07946-21 $223.71 Solid Waste Management Fee $6.25 Amount Due: $0.00 Total: $223.71 �/2- ( F74(_ CALLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. /0• Ca/'/'i;Cii/j,n //64X This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. EtEr COMPLETED June 17, 2021 Issued By:John Zurick Date June 17,2021 Page 1 of 1 • "1 A.r..il lii. \unllc,nifti°/ AFFIDAVIT SELF-CERTIFICATION FOR COMPLIANCE OF SMOKE ALARMS AND CARBON MONOXIDE ALARMS Property Address: / 3 Lkl c a fib sAyrdrc, Permit Number: Sa Brief Job Description: ,Snict r Number of smoke alarms installed: . Number of carbon monoxide alarms installed: 1 , When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created, Smoke alarms shall be installed in each sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2013 California Residential Code (CRC) and California Health and Safety Code Section 13113.7. For dwellings or sleeping units containing fuel burning appliances or having attached garages, carbon monoxide alarms shall be installed outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements as required by Section R315 of the of the 2010 California Residential Code (CRC). Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used. All alarms shall comply with requirements for listing and approval by the Office of the State Fire Marshall. http://ostm.fire.ca.gov/licensinglistings/Iicenselistina bml searchcotesi.php As owner of the above referenced property, I hereby certify that the smoke alarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance with the code sections referenced above. - i declare ender penalty of perjury that the foregoing is true and correct, and that this declaration was executed on (Date) at Arcadia., California. Owner's. Name (printed/typed): (il/f l2 i S 7.r-- - Signature of Owner: .. This affidavit must be returned to the illy of Arcadia inspector prior to final inspection r M1 t City of Arcadia, CA N '3 ' f PerrrrtNO SOLR;21 0195 Development Services Department ; t. v ,y Permit Type Solar' 240 West Huntington Drive,Post Office Box 60021 - ,, + ' ' � . ).� f Arcadia,CA 91066-6021 ;� `' I' Wcirk Classification.•.Solar'Residential` i (626)574-5416 'Permit Status Issued r A RCADIA issue Date.02/05/2021 1 Expiration: 02/07/2022 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 1038 ENCANTO DR Arcadia,CA 91007-6105 5776007003 . Contacts. ALBERT WU Owner TESLA ENERGY* Contractor 1038 ENCANTO DR 3055 Clearview Way,San Mateo,CA 94402 (626)991-0776 (323)240-3174 888104 y , k ";RYV.K r.945 Y - .s,40^. rP,.:. dP wA:::.. .. :e°r. SE'..":k`.v-i3f8k•.q"< '.:.L '"."4++.'..'.a. f.".a& ^.N"& .."ve"'YK'.,h.:;.a.: &x"':...4r*.i ... "!YI»:�w,..ro]"!dM. v.R:',HIR:. $^1•«:l. YGdI Description:ROOF MOUNT PV SYSTEM 24 MODULES/1 Valuation: $ 0.00 1 Tenant INVERTER Total Sq Feet: 0.00 r Plan Check# Plan# Tima Fees Amount Payments Amount Paid Building Plan Check Fee Residential $100.00 Total Fees $308.24 Electrical Permit Issuance Fee $47.01 Cash/Receipt#REC-06697-21 $308.24 Inverters $77.78 Panels $82.45 Amount Due: $0.00 Solid Waste Management Fee 2 $1.00 Total: $308.24 7—/2, 4 CALLS FOR INSPECTIONS Request for inspection by telephone'at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and . .., .. void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector fora period of 180 consecutive days. CPLTED February 05, 2021 Issued By:John Zurick Date February 08,2021 Page 1 of 1 I,I d ; City of Arcadia, CA ' Permit NO. ROOF21 1104 , „: +' Development Services Department ' r y yj-" - v„,--i y T - '6" ,: Perm�tType''ROOf' *t i 240 West Huntington Drive,Post Office Box 60021 `` Aq ' r m i - i i f Mf , t Work Classification:Reroof Residential jogArcadia,CA 91066-6021 L.) , -. „t I --) ;-4 J r (626)574-5416 a Permit Status:Issued ARCADIA.ADIA Issue Date:06/17/20211 Expiration: 06/17/2022 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 1038 ENCANTO DR Arcadia,CA 91007-6105 5776007003 Contacts I, ALBERT WU Owner ABOVE ALL CONSTRUCTION INC* Contractor t; 1038 ENCANTO DR 3343 DURAHART ST,RIVERSIDE,CA 92507 (626)991-0776 (951)742-7156 933062 Description:REMOVE TILE,REROOF HOUSE WITH MALARKEY == Valuation: $ 6,000.00 S Tenant DESET NOIR CLASS A 19 SQ UNDER SOLAR ARRAY SYSTEM ONLY (EA) , Total Sq Feet: 0.00 I Plan Check# Plan# Fees Amount Payments Amount Paid ;, Building Issuing Fee $47.01 Total Fees $223.71 Building Permit Fees $170.45 Cash/Receipt If REC-07946-21 $223.71 Solid Waste Management Fee $6.25 Amount Due: $0.00 Total: $223.71 - �//2'2( F/kii C --? . CALLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message requestinnggthe address,timeframe and what inspection item is needed. 4fil• 4 rAe 4',,w 4-Ce/li)6f/142-1 This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector fora period of 180 consecutive days. Zer COMPLETED j June 17, 2021 Issued By:John Zurick Date June 17,2021 Page 1 of 1