HomeMy WebLinkAboutApproved PlansHVAC HWT AC cover sheet + site plan a1.0 1/8 : 1'-0" 408 s. pasadena ave., unit 4 pasadena, ca 91105 855-550-2453 www.bildencorp.com 2222 S. 6th avenue arcadia, CA 91006 revision:date: project issued for consultants Planning review # 1 10.26.20 Planning review # 2 12.22.20 Planning review # 3 06.18.21 Planning review #4 08.30.21 Planning review #5 10.21.21 Planning review #5- rev.1 12.02.21 120'101'25'-0" 35'-0"10'-1"6th Avenue101'120' 35'-0"side setback(first floor)side setback(second floor)20'-2"rear setback (first floor) rear setback (second floor) front setback (see attached survey for verification of adjacent properties) property line north Jurisdiction: City of Arcadia Development Services Department All work shall comply with the following codes: 2019 California Building Code (2018 IBC) 2019 California Mechanical Code (2018 IMC) 2019 California Plumbing Code (2018 IPC) 2019 California Fire Code (2018 IFC) 2019 California Electrical Code (2017 NEC) 2019 California Residential Code (2018 IRC) 2019 California Green Building Standards Code 2019 California Energy Code. address: 2222 S. 6th Avenue Arcadia, CA 91006 legal description: Lot/Parcel Area 12,120 sf Parcel Number (APN) 5791-021-007 Tract + Lot Tract 22498, Lot 16 Map Book 600, pages 38 to 39 planning and zoning information: Zoning: R-1 Occupancy group: single family Occupancy type: residential Homeowners Assn: no Type of construction: Type V - wood frame construction Number of stories: 2 building height: maximum allowable 30' proposed 25'-9" parking spaces: parking spaces required 2 parking spaces provided 2 property informationcodes + regulations project description scope of work: Construction of a new 2 storey, Prairie Style, single family residence. floor area: maximum allowable 4500 + (40% x 2120) = 5,348 sf proposed floor area: 1st floor floor area 2,697 sf garage 455 sf (-450 sf) front porch 149 sf 1st fl total 2,851 sf 2nd floor floor area 1,727 sf high ceiling 71 sf stairway 58 sf 2nd fl total 1,856 sf total 4,707 sf lot coverage: 3179 sf floor area ratio: 4,707 sf (building area) / 12,120 sf (lot area) = 0.39 18'-0"driveway75'-3"proposed 2 storey single family residence garage 20' x 20' interior clear dim. owner information owner: Yaxing Investments Inc. 5457 Crestline Place Rancho Cucamonga, CA 91739 contact information (owner's agent): Joe Fedorowich Bilden Corp. 408 S. Pasadena Avenue Unit #4 Pasadena, CA 91105 (323) 336-0561 joef@bildencorp.com 30'-0"center line10'-101 2" parkway project address: 2222 6th Avenue Arcadia, CA 91006 drawing index architectural a1.0 cover sheet + site plan a2.1 first floor plan a2.2 second floor plan a2.3 roof plan a3.1 elevations a3.2 elevations a3.3 sections a4.1 door + window schedules a6.1 stair a7.1 details landscape l1.0 landscape plan demolition d1.0 demolition plan survey T-1 topographic map existing power pole 6' high CMU wall on neighboring property vicinity map north10'-1"20'-2"side setback(second floor)side setback(first floor)existing 4" dia. Pomegranate tree to remain existing 4" dia. Chinese pistache tree to remain existing 4" dia. Chinese pistache tree to remain existing 4" dia. Chinese pistache tree to remain existing 4" dia. Chinese pistache tree to remain existing 4" dia. Chinese pistache tree to remain 2222 S 6th Avenue front yard hardscape: front yard 3535 sf paved area 1248 sf landscaped area 2287 sf hardscape 35% (less than 40%, complies) curbs and gutters shall be replaced per City standards 40'-0" front setback to second floor to center line of street second floor52'-8" driveway pavers: Angelus Paving Stones Aqualina modular brick pavers color blend: dark gray - pewter - charcoal walkway pavers: cast in place concrete 3' x 6' pavers with offset layout patio & perimeter pavers: Daltile - 'Dignitary' 24 x 24 D10 Eminance Gray matte finsih second floor8'-6" garage to front of facade site plan 1 8" = 1'-0" 31'-4" 39'-0" first floor to property line second floor to property line second floor11'-1"property line tofirst floor wall14'-8"property lineto first floor wall21'-2"property line tosecond floor wall26'-8"property line tosecond floor wallCONDITIONALLY APPROVED 12-28-21 roof plan a2.3 1 4" : 1'-0" north first floor setback second floor setback slope 3 : 12 typical future solar 408 s. pasadena ave., unit 4 pasadena, ca 91105 855-550-2453 www.bildencorp.com 2222 S. 6th avenue arcadia, CA 91006 revision:date: project issued for consultants Planning review # 1 10.26.20 Planning review # 2 12.22.20 Planning review # 3 06.18.21 Planning review #4 08.30.21 Planning review #5 10.21.21 Planning review #5- rev.1 12.02.21 3'-0"w-33 skylight at laundry w-34 skylight at stair 1 a7.1typ. aa bb bb aa 3'-6"1'-0"2'-6"wall belowsecond floor roof 30" max projection of roof into setback, typical 1eave detail 3/4" : 1'-0" 1'-0"2'-6" 3'-6"setback30" max projection of roof into setback, typical second floor setback first floor setback second floor setbackfirst floor setback1a2.3typ.1a2.3typ.first floor roof first + second floor setback1 a2.3typ.CONDITIONALLY APPROVED 12-28-21 elevations a3.1 1 4" : 1'-0" west elevation front south elevation a height limit 30' encr o a c h m e nt pl a n e 30° fr o m fr o nt pr o p ert y li n e front property line b b e f typical for trim c 2 a7.1 typ.10'-0"9'-0"25'-9"roof second fl. first fl. d d typical for gutters + downspouts e 2 a7.1 typ. d typical for gutters + downspouts a d-01 w-01w-02 w-03 d-02 408 s. pasadena ave., unit 4 pasadena, ca 91105 855-550-2453 www.bildencorp.com 2222 S. 6th avenue arcadia, CA 91006 revision:date: project issued for consultants Planning review # 1 10.26.20 Planning review # 2 12.22.20 Planning review # 3 06.18.21 Planning review #4 08.30.21 Planning review #5 10.21.21 Planning review #5- rev.1 12.02.21 w-20 w-19 w-32 w-16 w-15 w-14 w-13 w-12 w-11 d-10 w-28w-31 w-18 w-17 b height limit 30'10'-0"9'-0"25'-9"roof second fl. first fl.30° b b f b b b b f typical for trim b b w-30 1 a2.3 typ. 1 a2.3typ. privacy glass at bathrooms w-29 exterior materials: a stone veneer: Arriscraft Lombard Midtown Thin Flat 2 1 8", Split face (rough texture) b stucco: LaHabra / Merlex X-81 Oatmeal smooth finish - Santa Barbara c garage door: Clopay Canyon Ridge Carriage House design: 11 window pattern: REC13 color: Ultra-Grain Walnut d gutters & downspouts: Dunn Edwards DE6070 Chocolate Chunk Aristoshield: interior / exterior sheen: Eggshell e roofing: Boral Roofing Saxony 900 Slate Concrete tile color: Rustic Brown Blend cool roof compliant f trim: Dunn Edwards DE6123 Trail Dust Aristoshield: interior / exterior sheen: Eggshell d typical for gutters + downspouts f typical for trim CONDITIONALLY APPROVED 12-28-21 408 s. pasadena ave., unit 4 pasadena, ca 91105 855-550-2453 www.bildencorp.com 2222 S. 6th avenue arcadia, CA 91006 revision:date: project issued for consultants Planning review # 1 10.26.20 Planning review # 2 12.22.20 Planning review # 3 06.18.21 Planning review #4 08.30.21 Planning review #5 10.21.21 Planning review #5- rev.1 12.02.21 elevations a3.2 1 4" : 1'-0" east elevation rear north elevation en c r o a c h m e n t p l a n e 30 ° f r o m f r o n t p r o p e r t y l i n e front property line2 a7.1 typ. 2 a7.1 typ. d-07 w-09 w-07w-08 w-10 w-24w-25w-26w-27 d-06d-08d-09 w-04 w-05w-06 30°w-22w-23 d-03 d-05 d-04 height limit 30'10'-0"9'-0"25'-9"roof second fl. first fl. height limit 30'10'-0"9'-0"25'-9"roof second fl. first fl. a b b e d b b b f a b b e b b b f typical for trim w-21 privacy glass at bathroom exterior materials: a stone veneer: Arriscraft Lombard Midtown Thin Flat 2 1 8", Split face (rough texture) b stucco: LaHabra / Merlex X-81 Oatmeal smooth finish - Santa Barbara c garage door: Clopay Canyon Ridge Carriage House design: 11 window pattern: REC13 color: Ultra-Grain Walnut d gutters & downspouts: Dunn Edwards DE6070 Chocolate Chunk Aristoshield: interior / exterior sheen: Eggshell e roofing: Boral Roofing Saxony 900 Slate Concrete tile color: Rustic Brown Blend cool roof compliant f trim: Dunn Edwards DE6123 Trail Dust Aristoshield: interior / exterior sheen: Eggshell d typical for gutters + downspouts d typical for gutters + downspouts d typical for gutters + downspouts f typical for trim f typical for trim CONDITIONALLY APPROVED 12-28-21 408 s. pasadena ave., unit 4 pasadena, ca 91105 855-550-2453 www.bildencorp.com 2222 S. 6th avenue arcadia, CA 91006 revision:date: project issued for consultants Planning review # 1 10.26.20 Planning review # 2 12.22.20 Planning review # 3 06.18.21 Planning review #4 08.30.21 Planning review #5 10.21.21 Planning review #5- rev.1 12.02.21 sections a3.3 1 4" : 1'-0" section aa section bb upper gallery entry hall study closet upper gallery entry hall dining room height limit 30' height limit 30' guest bath laundrybath master bedroom garage10'-0"9'-0"25'-9"roof second fl. first fl.10'-0"9'-0"25'-9"roof second fl. first fl.skylight aligns to stair belowCONDITIONALLY APPROVED 12-28-21 Specifications Windows & Patio Doors manufacturer Andersen, e-series wood & aluminum model Architectural Collection style Prairie Style w/ grille type operable & fixed windows, glazed doors color Cocoa Bean Entry Door manufacturer Andersen, e-series wood & aluminum style custom entry door - see door type g color Cocoa Bean Skylight manufacturer Velux model FS - fixed, deck mounted material aluminum type fixed, flat glass, deck mounted color kynar 500 cool gray (standard) glass temp over laminated, low e Garage door (auto door) manufacturer Clopay - steel with composite overlay model Canyon Ridge Carriage House finish Ultra-Grain Walnut Typical door manufacturer TBD (various manufacturers) model slab or shaker style as shown material paint grade wood, fiberglass or metal color exterior - Andersen 'Cocoa Bean' interior - TBD schedules a4.1 window schedule numbertyperemarks1 2 3 4 5 6 8 9 10 11 12 13 u factorSHGC14 15 16 17 18 19 *all new glazing to be dual pane, w/ low-E coating tempered glass2 pane, low Eegress20 21 22 door schedule numberfinishwidthfinishheighttyperemarks1 2 3 4 5 6 8 9 10 11 12 13 u factorSHGC14 15 16 17 18 19 *all new glazing to be dual pane, w/ low-E coating tempered glass2 pane, low Ehardware set77 72"g w/ sidelights w1 & w2 main entry door 23 90"f72" 1. Exterior Glazing: All exterior windows, skylights etc. are required to be tempered glass and dual glazing. 2. CONTRACTOR TO FIELD VERIFY ALL OPENINGS PRIOR TO ORDERING 3. Doors between garage and the dwelling unit shall have a minimum fire protection rating of 20 minutes and self-closing and self-latching devices, or solid wood or solid honeycomb core steel not less than 1 3 8" thick. 1. Exterior Glazing: All exterior windows, skylights etc. are required to be tempered glass and dual glazing. 2. CONTRACTOR TO FIELD VERIFY ALL OPENINGS PRIOR TO ORDERING WINDOWSfinishwidthfinishheightroughopeningwidth height headroughopeningwidth height jamb (rough)96"first floorsecond floor24 25 26 skylightsEgress Windows: A finished sill height above the finished floor of 44" or less. A minimum opening of 5.7 square feet net clear area. A minimum net clear opening dimension of 20" in width. A minimum net clear opening dimension of 24" in height. e window types a b c e guest garage 27" 48"b kitchen d 36" 96"c 27 28 29 30 31 32 33 34 4'-10"2'-3"4'-0"4'-0"20 21 22 23 24 25 26 27 28 29 30 31 32 swing direction varies, see elevations door types a - shaker style b - swing door c - pocket 192"f garage door84" 32" 84" 60" 60" 72" f - garage door b e 60"e 60" 60"7'-0"16'-0" fire rated - see note 3 below swing direction varies, see plans slide direction varies, see plans d - bypass closet door 84" 84" 84" 32" 32" 48" b 60" 32" 32" 32" 32"first floorsecond floorg - entry door w/ sidelights & decorative glass varies variesvaries varies8'-0"5'-0"8'-0"swings out 58" 48"j upper gallery master closet varies 4'-0"4'-0"i j k varies 8'-0"5'-0"6'-0"6'-0"1'-6"5'-6"(egress where noted on schedule) 7'-5"4'-0"3'-6"4'-10"2'-3" swing direction varies, see elevations swing direction varies, see elevations d-00 w-00 72" 18" 58" 48"a 18" 96"see door type g 18" 96"see door type g entry - sidelight coord. w/ entry door kitchen 36" 96"c kitchen 30" 72"g dining 30" 72"g dining 60" 72"d family 60"d family 60"d living 60"d living 30" 72"g study 30" 72"g study master bedroom master bedroom j j 58" 58" master bath - provide privacy glass master bath 27"k upper gallery bath 2 - provide privacy glass bedroom 2 bedroom 2 bedroom 1 22" 22"laundryskylight varies84" 96" 96" paint grade e e 60"e b d a 60"a c c 60" 60" 33 36" 32" 32" 32" 32" b b b d b b b b 89"h j58" c b 46" 22"skylight over stairskylight 408 s. pasadena ave., unit 4 pasadena, ca 91105 855-550-2453 www.bildencorp.com 2222 S. 6th avenue arcadia, CA 91006 revision:date: project issued for consultants Planning review # 1 10.26.20 Planning review # 2 12.22.20 Planning review # 3 06.18.21 Planning review #4 08.30.21 Planning review #5 10.21.21 Planning review #5- rev.1 12.02.21 paint grade paint grade a a 84"32"b 96"32"b 32"b 36"c 36"c 84"32"b f 7'-6"6'-0"2'-0"60"d living 60"d living mud master bedroom bedroom 1 96" 96" 96" 96" 96" 96" 96" 96" 96" 96" 96" 84" 84" 84" 84" 84" 84" 84" 84" 84" 84" 119" 34 d84"119"2'-0"3'-6"3'-6"4'-0"4'-0"g 2'-6"6'-0"2'-0"72" 72" 72" 72" 72" 89" 48"i 48" 48" 48" 48" 48" 89"i48" 89"i48" 89"i48" j58" 48" j58" 48" 27"l48" 27"l48"bath 1 - provide privacy glass wood & aluminum steel w/ composite overlay wood & aluminum wood & aluminum wood & aluminum wood & aluminum & glass wood wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum wood & aluminum aluminum aluminum wood wood wood wood wood wood wood wood wood wood wood wood wood wood wood wood wood wood wood wood wood wood wood wood & aluminum & glass wood & aluminum & glass wood & aluminum & glass wood & aluminum & glass materials materials 1'-6"1'-6" h 7'-5"4'-0"3'-6"e - glazed swing door varies 8'-0"6'-0" entry - sidelight coord. w/ entry door swing direction varies, see elevations l 2'-3"3'-6"4'-0"CONDITIONALLY APPROVED 12-28-21 408 s. pasadena ave., unit 4 pasadena, ca 91105 855-550-2453 www.bildencorp.com 2222 S. 6th avenue arcadia, CA 91006 revision:date: project issued for consultants Planning review # 1 10.26.20 Planning review # 2 12.22.20 Planning review # 3 06.18.21 Planning review #4 08.30.21 Planning review #5 10.21.21 Planning review #5- rev.1 12.02.21 C.L. handrailabove treadstair a6.1 3 4" : 1'-0"3'-0"136" = 18 risers at 7.55"7 916"11"3'-6"top of guardrailtypical42" h guardrail, typ. 1 1 2" Ø handrail 36" above tread nosing112"Øhandrail7 34"max.10" min. handrail stair elevation stair detail plan stair notes: a) Minimum run (tread) of 10" and shall be provided with 0.75" to 1.25" nosing. b) Handrails shall not project more than 4.5" on either side of the stairway. The clear stairway width at and below the handrail shall be 31 1 2" where a handrail is installed on one side and 37" where handrails are installed on both sides. (R311.7.1) c) Provide min 1 1 2" space from handrail to wall. (R311.7.8.2) d) Handrails (Type I) shall be at least 1.25" and not more than 2" outside diameter. If handrail is not circular, it shall have a perimeter dimension of at least 4" and not greater than 6.25" and a maximum cross-sectional dimension of 2.25". (R311.7.8.3) e) Handrails (Type II) with a perimeter greater than 6 1 4" shall have a graspable finger recess area on both sides of the profile. Recesses shall begin within 3 4" from the tallest portion of the profile and be at least 5 16" deep within 7 8" below the widest portion of the profile. This required depth shall continue for at least 3 8" to a level that is not less than 1 3 4" below the tallest portion of the profile. The minimum width above the recess shall be 1 1 4" to 2 3 4". (R311.7.8.3) CBC Section R311.7.5.2.1 Winder Treads R311.7.5.2.1 Winder treads. Winder treads shall have a tread depth of not less than 10 inches (254mm) measured between the vertical planes of the foremost projection of adjacent treads at the inter-sections with the walkline. Winder treads shall have a tread depth of not less than 6 inches (152 mm) at any point within the clear width of the stair. Within any flight of stairs, the largest winder tread depth at the walkline shall not exceed the smallest winder tread by more than 3/8 inch (9.5 mm). Consistently shaped winders at the walkline shall be allowed within the same flight of stairs as rectangular treads and do not have to be within 3/8 inch (9.5 mm) of the rectangular tread depth. 42" h guardrail, typ. up 18 R @ 7.55" 1 8'-3"16'-2" 3'-0"3'-11"3'-0"4'-10" tread width at walkline tread typical 11'-4"11 2"Ø 2 3 4 5 6 7 8 9 11" 10 11 12 13 14 15 16 17 18 101 4"see section for alignment of skylight aboveCONDITIONALLY APPROVED 12-28-21 insulation per plan painted drywall 2"painted MDF trim window assembly 2 x 4 blocking for flanged window 2 x 6 framing (typ. at exterior walls) sheathing per structural code approved building wrap exterior sill, slope to drain window flange taped to house wrap stucco house wrap overlaps flashing sloped metal flashing 3 4" exterior window head / jamb trim window flange taped to house wrap 23 8" 2" min. from f/o finish 408 s. pasadena ave., unit 4 pasadena, ca 91105 855-550-2453 www.bildencorp.com 2222 S. 6th avenue arcadia, CA 91006 revision:date: project issued for consultants Planning review # 1 10.26.20 Planning review # 2 12.22.20 Planning review # 3 06.18.21 Planning review #4 08.30.21 Planning review #5 10.21.21 Planning review #5- rev.1 12.02.21 details a7.12window detail 3" = 1'-0"1skylight detail n.t.s.CONDITIONALLY APPROVED 12-28-21 HVAC HWT AC landscape plan l1.1 3 16" : 1'-0" 408 s. pasadena ave., unit 4 pasadena, ca 91105 855-550-2453 www.bildencorp.com 2222 S. 6th avenue arcadia, CA 91006 revision:date: project issued for consultants Planning review # 1 10.26.20 Planning review # 2 12.22.20 Planning review # 3 06.18.21 Planning review #4 08.30.21 Planning review #5 10.21.21 Planning review #5- rev.1 12.02.21 existing fence at property line to remain Landscape Lighting: symbol type quantity model specification color lamp Path Light x Corona 718B CL-718B-AB-L-EDT3-2W antique bronze 2700K, 2w LED Up / Accent x Corona 517B CL-517B-AB-L-EDT3-2W antique bronze 2700K, 2w LED landscape notes: 1. Demo existing planting (sod, grass, weeds, etc.) 2. Verify soil conditions. Add amendments and break up compacted soil where necessary. 3. Irrigation to be designed by installer. Follow applicable codes and provide irrigation plan. Irrigation system shall include rain sensor and remote (web based) control. 4. Provide weed barrier and 2" thick mulch at planting beds. 5. Provide bender board edge trim at planting beds, gravel areas, and grass areas. 6. Plants to be laid out (in containers) per plan, by installer. Owner / Architect will review prior to final planting. 7. Plants shall be maintained and monitored for health for one year from completion of install. Dead or unhealthy plants shall be replaced. north 'Wilsoni' fruitless Olive Olea europaea 3 @ 48" box multi trunk plant list large icon: California Sycamore Platanus racemosa 3 @ 48" box, multi trunk Blood-red Trumpet Vine Distictis buccinatoria 5 @15 gallon Podocarpus gracilior 18 @ 15 gal. Lavender 'Phenomenal' L. x intermedia 'Phenomenal' (verify quantity) @ 1 gal Rosemary - 'Tuscan blue' (upright shrub) 2 @ 5 gal south patio east lawn east patio kitchen garden entry porch west patio citrus grove Olive trees to screen south neighbor trash bins lightsirrigationIrrigation system shall include rain sensor and web based control. existing 6' high masonry wall (on neighbors' property) existing 6' high hedge (on neighbors' property) small icon: Citrus - various species 5 36" box Strawberry Tree Arbutus unedo 2 @ 36" box multi trunk Compact Strawberry Tree Arbutus unedo compacta 7 @ 24" box new wood slat fence Giant Chain Fern Woodwardia fimbriata (verify quantity) @ 15 gal. White Iceberg Shrub Rose Rosa ssp. 'Iceberg' (verify quantity) @ 15 gal. Creeping Jasmine Trachelospermum jasminoides (verify quantity) @ 5 gal. Marathon sod Red Fescue sod Catmint (verify quantity) @ 5 gal this project will comply with the City's Water Efficient Landscaping Ordinance (WELO). an application will be submitted with Building & Safety review. 13'-6"10'-6"16'-0"18'-0" 10'-0"29'-9"12'-0"20'-10"CONDITIONALLY APPROVED 12-28-21 demolition plan d1.0 1/8 : 1'-0" 408 s. pasadena ave., unit 4 pasadena, ca 91105 855-550-2453 www.bildencorp.com 2222 S. 6th avenue arcadia, CA 91006 revision:date: project issued for consultants Planning review # 1 10.26.20 Planning review # 2 12.22.20 Planning review # 3 06.18.21 Planning review #4 08.30.21 Planning review #5 10.21.21 Planning review #5- rev.1 12.02.21 120'101'6th Avenue101'120'property line north demolish existing 1 storey 2801 SF single family residence center lineproject address: 2222 6th Avenue Arcadia, CA 91006 demolition plan 1 8" = 1'-0" demolish existing 512 SF garage 14'-1012"80'-538"5'-814"33'-8"50'-47 8"35'-111 8" 21'-45 8"2'-81 2"23'-1158"2'-858"1. Comply with all applicable codes and regulations regarding demolition. 2. Turn off all electrical, plumbing, and utilities prior to demolition. Provide appropriate termination of all utilities impacted by demolition. 3. Dispose of all waste materials in accordance with Waste Management Plan. Provide documentation as required. demolition notes CONDITIONALLY APPROVED 12-28-21