Loading...
HomeMy WebLinkAboutPlans2% min2% min 2019 CALIFORNIA PLUMBING CODE: (CPC) PART 5, TITLE 24, CCR; BASED ON THE 2018 UNIFORM PLUMBING CODE (UPC) 2019 CALIFORNIA MECHANICAL CODE (CMC): PART 4, TITLE 24, CCR;BASED ON THE 2018 UNIFORM MECHANICAL CODE (UMC) 2019 CALIFORNIA ELECTRICAL CODE (CEC): PART 3, TITLE 24, CCR; BASED ON THE 2017 NATIONAL ELECTRICAL CODE (NEC) 2019 CALIFORNIA RESIDENTIAL CODE: PART 2, TITLE 24, CCR; BASED ON THE 2018 INTERNATIONAL BUILDING CODE (IBC) 2019 CALIFORNIA FIRE CODE(CFC): PART 9, TITLE 24, CCR, BASED ON THE 2018 INTERNATIONAL FIRE CODE (IFC) ENERGY CODE: 2019 CALIFORNIA ENERGY CODE -PART 6, TITLE 24, CCR ACCESSIBILITY CODE: CHAPTER 11/11B, 2019 CBC AND 2010 ADA (28 CFR PART 36) LIFE SAFETY CODE: 2000 NFPA 101 LIFE SAFETY CODE CALGREEN: 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE -PART 11, TITLE 24, CBSC 2019 CALIFORNIA FIRE CODE(CFC): PART 9, TITLE 24, CCR, BASED ON THE 2018 INTERNATIONAL FIRE CODE (IFC) 2019 CALIFORNIA BUILDING CODE (CBC): PART 2, TITLE 24, CCR; BASED ON THE 2018 INTERNATIONAL BUILDING CODE (IBC) BUILDING CODE 1. G.C. TO VERIFY ALL EXISTING DIMENSION AND CONDITIONS. 2. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOLID WASTE, PETROLEUM BYPRODUCTS, SOIL PARTICULATE, CONSTRUCTION WASTE MATERIALS OR WASTEWATER GENERATED ON CONSTRUCTION SITES OR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN SYSTEM. 3. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (PEOPER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON HE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. 4. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM THE FOUNDATION WALLS. THE GRADE SHALL FALL A MIN. OF 6" WITHIN THE FIRST 10' (5%). WHERE LOT LINES, WALLS, SLOPES OR OTHER PHYSICAL BARRIER PROHIBIT 6" OF FALL WITHIIN 10', DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE [CRC R401.3]. 5. IMPERVIOUS SURFACES WITHIN 10' OF THE BUILDING FOUNDATION SHALL BE SLOPED A MIN OF 2% AWAY FROM THE BUILDING [CRC R401.3 EXCEPTION]. GENERAL NOTES - SITE PLAN FLOOR AREA DESCRIPTION EXISTING NEW TOTAL S.F. S.F. S.F. S.F. S.F. S.F. S.F.TOTAL RFA FIRST FLOOR 1582 300 SECOND FLOOR 800 1882 800 2682 LOT COVERAGE TABLE MAX LOT COVERAGE MAX ALLOWED % S.F. ACTUAL LOT COVERAGE % RESIDENCE GARAGE EXISTING NEW TOTAL S.F.1582 S.F. S.F.300 S.F. S.F. S.F. S.F.TOTAL COVERAGE LOT SIZE S.F.9440 462 1882 462 2344 24 GRASS/TURF AREA OF REMODEL (E) DWELLING LEGEND - SITE (N) ADDITION CONCRETE PLANTER AREA 1 A101 SIM NORTH ARROWDOOR TAG WINDOW TAG ROOM TAG REF. BUBLE SECTION TAG ELEVATION TAG SLOPE ARROW REVISION TAG SUPPLY REGISTER RETURN AIR 1 A101 SIM LEGEND - SYMBOL 101 1 1i Room name 101 A101 1 Ref 1Re f 1 Re f 1 Ref 85' - 0"40' - 7"21' - 5" 4' - 6 " 46 ' - 6 " 9' - 0 " (E) 2-CAR GARAGE (E) SOFTSCAPE (E) HARDSCAPE (E) DRIVEWAY (E) SOFTSCAPE (N) 2 STORY ADDITION (E) SFR (E) HVAC (E) WATER METER PROPERTY LINE: 147' PROPERTY LINE: 147' PR O P E R T Y L I N E : 6 0 ' PR O P E R T Y L I N E : 6 0 ' ES T R E L L A A V E . 30' - 9"35' - 2"31' - 6" 60 ' - 0 " 1 15 ' - 0 " (E) AVACADO TREE 18" DIA. 1 2 3' - 3" LI C E N S E D ARCHIT E C T S T A T E OF C A L I F O RNINA MICHAEL SONG LIC.# C-32566 EXP: 12/31/21 Scale Project number Date Drawn by Checked by ARCHITECTURE DESIGN 821 Lime Ave Long Beach CA 90813 626.375.3073 Al l p l a n s , d e s i g n s , a r r a n g e m e n t s a n d i d e a s i n d i c a t e d o r r e p r e s e n t e d o n t h i s d r a w i n g s h e e t a r e " I n s t r u m e n t s o f S e r v i c e " a n d p r o p e r t y o f M A A r c h i t e c t s . A s s u c h , t h e y a r e i n t e n d e d f o r u s e s p e c i f i c a l l y o n t h i s p r o j e c t o n l y . N o n e o f th e p l a n s , d e s i g n s , a r r a n g e m e n t s o r i d e a s o f t h i s d r a w i n g s h e e t / s e t s h a l l b e u s e d , d i s c l o s e d , a l t e r e d , o r r e p r o d u c e d b y a n y p e r s o n , f i r m , o r c o r p o r a t i o n f o r a n y p u r p o s e w h a t s o e v e r w i t h o u t w r i t t e n p e r m i s s i o n o f M A A r c h i t e c t s . PROJECT DIRECTORY ARCHITECT 821 LIME AVE LONG BEACH CA 90813 TEL: 626.375.3073 PROJECT ARCHITECT: MICHAEL SONG E: MICHAEL.STUDIOMA@GMAIL.COM PROJECT DATA ADDRESS: OWNER: As indicated 9/ 1 5 / 2 0 2 2 3 : 5 7 : 1 7 P M G0-01 SI T E P L A N 12_33 LE O N A R D C H E N & L I Z L I U RE S I D E N C E 12-21-14 Author Checker 71 7 E S T R E L L A A V E , AR C A D I A , C A 9 1 0 0 7 717 ESTRELLA AVE, ARCADIA, CA 91007 LEONARD CHEN & LIZ LIU RESIDENCE 717 ESTRELLA AVE, ARCADIA, CA 91007 LELONARD CHEN & LIZ LIU APN: LEGAL: PROJECT SCOPE: 5383-023-038 SANTA ANITA LAND CO'S TR W 60 FT OF E 245.10 FT OF N 147 FT OF LOT 5 BLK H REMODEL KITCHEN, LAUNDRY, LIVING ROOM. (N) 300 S.F. ADDITION TO 1ST FLOOR. (N) 800 S.F. 2ND STORY ADDITON TYPE V R-3 R-1 2 STORIES 22' NO TYPE OF CONSTRUCTION: OCCUPANCY GROUP: ZONING: NUMBER OF STORIES: BUIDING HEIGHT: SPRINKLED: 1 : 13VICINITY MAP 1/8" = 1'-0"6 Site Plan Sheet List Sheet Number Sheet Name G0-01 SITE PLAN G0-02 GENERAL NOTES G0-03.1 CAL GREEN_2019 G0-03.2 CAL GREEN_2019 G0-04.1 TITLE 24 G0-04.2 TITLE 24 A1-01 DEMO PLAN A2-01 FIRST & SECOND FLOOR PLAN A3-01 ROOF PLAN A4-01 ELEVATIONS A4-03 BUILDING SECTIONS A7-01 STANDARD DETAILS No. Description Date 1 PLN REV 1 5/15/22 2 PLN REV 2 8/10/22 EDB 2 3 4 A 5 1 C (E) ROOF (N) ROOF TO MATCH (E) (N) SOFFIT VENTS F 4" / 1 ' - 0 " 4" / 1'-0" 4" / 1 ' - 0 " 4" / 1'-0" 4" / 1 ' - 0 " 4" / 1'-0" 1' - 6" 1' - 6 " 1' - 6" 1' - 6 " 1' - 6 " (N )ROOF VENTS 1. THE REPLACEMENT OF THE ROOF SHALL BE CONDUCTED IN SUCH A MANNER AS TO PROTECT THE EXISTING DWELLING UNIT AND ALL OF ITS CONTENTS IN THEIR ENTIRETY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE CAUSE DURING THE PERFORMANCE OF THEIR CONTRACT WORK. 2. FIELD VERIFY SIZE AND LOCATION OF ALL EXISTING MECHANICAL UNITS, ROOF CURBS, ROOF DRAINS, SCUPPERS, SKYLIGHTS AS WELL AS ANY AND ALL OTHER PENETRATIONS OR ROOF ACCESSORIES AND INSTALL NEW ROOF AS REQUIRED TO ACCOMMODATE ACCESSORIES AND CREATE A WATER TIGHT SEAL OVER ENTIRE ROOF. 3. REFER TO ROOFING MANUFACTURES WRITTEN INSTRUCTIONS AND DETAILS FOR ROOFING SYSTEM INSTALLATION. CONTRACTOR TO PROVIDE COMPLETE ROOFING PACKAGE PER MANUFACTURERS RECOMMENDATIONS. 4. (N) FASCIA TO MATCH EXISTING 5. (N) ROOFING TO MATCH EXISTING UNLESS NOTED OTHERWISE GENERAL NOTES - ROOF PLAN AREA VENT AREA @150/S.F.VENT TYPE CAPASITY QTY TOTAL VENT AREA TOTAL VENT AREA PROVIDED 42 + 714 = 756 S.F.S.F..3 S.F.S.F.14X5 SOFFIT VENT 1 S.F.S.F.14" DIA. ROOF VENT 5.5 X 150 = 825 S.F. ATTIC VENTILATION TABLE 5.04 4 4 5 1.5 LI C E N S E D ARCHIT E C T S T A T E OF C A L I F O RNINA MICHAEL SONG LIC.# C-32566 EXP: 12/31/21 Scale Project number Date Drawn by Checked by ARCHITECTURE DESIGN 821 Lime Ave Long Beach CA 90813 626.375.3073 Al l p l a n s , d e s i g n s , a r r a n g e m e n t s a n d i d e a s i n d i c a t e d o r r e p r e s e n t e d o n t h i s d r a w i n g s h e e t a r e " I n s t r u m e n t s o f S e r v i c e " a n d p r o p e r t y o f M A A r c h i t e c t s . A s s u c h , t h e y a r e i n t e n d e d f o r u s e s p e c i f i c a l l y o n t h i s p r o j e c t o n l y . N o n e o f th e p l a n s , d e s i g n s , a r r a n g e m e n t s o r i d e a s o f t h i s d r a w i n g s h e e t / s e t s h a l l b e u s e d , d i s c l o s e d , a l t e r e d , o r r e p r o d u c e d b y a n y p e r s o n , f i r m , o r c o r p o r a t i o n f o r a n y p u r p o s e w h a t s o e v e r w i t h o u t w r i t t e n p e r m i s s i o n o f M A A r c h i t e c t s . 1/4" = 1'-0" 9/ 1 5 / 2 0 2 2 3 : 5 7 : 0 3 P M A3-01 RO O F P L A N 12_33 LE O N A R D C H E N & L I Z L I U RE S I D E N C E 12-21-14 Author Checker 71 7 E S T R E L L A A V E , AR C A D I A , C A 9 1 0 0 7 1/4" = 1'-0"1 2ND FC/ROOF LARR#25271 CLASS: A No. Description Date 1st FF 0" 2ND FF 9' -0" GRADE -1' -6" 2 3 4 2ND FC 17' -0" 5 1st FC 8' -0" 1 8 9 (N) STUCCO TO MATCH (E) (E) STUCCO (E) ROOF (N) ROOF TO MATCH (E) SEE ROOF SPEC A3-01 ROOF 22' -0" BU I L D I N G H E I G H T 23 ' - 6 " 3' - 2 " 1 14 (N) ROOF VENT 3 1st FF 0" 2ND FF 9' -0" GRADE -1' -6" EDB 2ND FC 17' -0" A 1st FC 8' -0" C (N) STUCCO TO MATCH (E) (E) STUCCO (E) ROOF (N) ROOF TO MATCH (E) SEE ROOF SPEC A3-01 ROOF 22' -0" BU I L D I N G H E I G H T 23 ' - 6 " F (E) ROOF 10 11 12 (N) ROOF VENT REMOVE STUCCO BORDER. FRONT ELE. WINDOWS TO HAVE COLONIAL STYLE BORDER MATCH COLONIAL STYLE BORDER 1st FF 0" 2ND FF 9' -0" GRADE -1' -6" E D B 2ND FC 17' -0" A 1st FC 8' -0" C 76 6 5 ROOF 22' -0" BU I L D I N G H E I G H T 23 ' - 6 " (N) STUCCO TO MATCH (E) (E) STUCCO (E) ROOF (N) ROOF TO MATCH (E) SEE ROOF SPEC A3-01 F 4" 1'-0" 4" 1'-0" (N) STUCCO TO MATCH (E) 3 1st FF 0" 2ND FF 9' -0" GRADE -1' -6" 234 2ND FC 17' -0" 5 1st FC 8' -0" 1 2 5 ROOF 22' -0" BU I L D I N G H E I G H T 23 ' - 6 " (N) STUCCO TO MATCH (E) (E) STUCCO (E) ROOF (N) ROOF TO MATCH (E) SEE ROOF SPEC A3-01 4" 1'-0" 13 (N) ROOF VENT 1. G.C.TO VERIFY ALL EXISTING DIMENSION AND CONDITIONS 2. UNDER FLOOR VENTILATION SHALL BE NOT LESS THAN 1/150 OF UNDER FLOOR AREA. 3. ATTIC VENTILATION OF 1/150 OF THE AREA OF VENTILATED SPACE WILL BE PROVIDED. 4. GLAZING IN HAZARDOUS LOCATIONS SHALL BE TEMPERED. 5. GLAZING IN INGRESS AND EGRESS DOORS TO BE TEMPERED GLAZING. A. PANELS IN SLIDING AND SWINGING DOORS TO BE TEMPERED GLAZING. B. DOORS AND ENCLOSURE FOR HOTTUB, BATHTUB, SHOWERS DOORS TO BE TEMPERED GLAZING. C. PROVIDE TEMPERED GLAZING IF WITHIN 2' OF VERTICAL EDGE OF A CLOSED DOOR AND WITHIN 5' OF STANDING SURFACE. 6. THE HIGHEST POINT OF THE ROOF, EQUIPMENT, OR ANY VENT, PIPE, ANTENNA OR OTHER PROJECTION SHALL NOT EXCEED THIRTY FEET ABOVE GRADE. 7. PROTECTION OF WOOD AND WOOD BASED PRODUCTS FROM DECAY SHALL BE PROVIDED IN THE LOCATIONS SPECIFIED PER SECTION R317.1 BY THE USE OF NATURALLY DURABLE WOOD OR WOOD THAT IS PRESERVATIVE-TREATED IN ACCORDANCE WITH AWPA U1 FOR THE SPECIES, PRODUCTS , PRESERVATIVE AND END USE. PRESERVATIVES SHALL BE LISTED IN SECTION 4 OF AWPA U1. 8. G.C. TO MATCH EXISTING EAVE OVERHANG GENERAL NOTES - ELEVATION LI C E N S E D ARCHIT E C T S T A T E OF C A L I F O RNINA MICHAEL SONG LIC.# C-32566 EXP: 12/31/21 Scale Project number Date Drawn by Checked by ARCHITECTURE DESIGN 821 Lime Ave Long Beach CA 90813 626.375.3073 Al l p l a n s , d e s i g n s , a r r a n g e m e n t s a n d i d e a s i n d i c a t e d o r r e p r e s e n t e d o n t h i s d r a w i n g s h e e t a r e " I n s t r u m e n t s o f S e r v i c e " a n d p r o p e r t y o f M A A r c h i t e c t s . A s s u c h , t h e y a r e i n t e n d e d f o r u s e s p e c i f i c a l l y o n t h i s p r o j e c t o n l y . N o n e o f th e p l a n s , d e s i g n s , a r r a n g e m e n t s o r i d e a s o f t h i s d r a w i n g s h e e t / s e t s h a l l b e u s e d , d i s c l o s e d , a l t e r e d , o r r e p r o d u c e d b y a n y p e r s o n , f i r m , o r c o r p o r a t i o n f o r a n y p u r p o s e w h a t s o e v e r w i t h o u t w r i t t e n p e r m i s s i o n o f M A A r c h i t e c t s . 1/4" = 1'-0" 9/ 2 0 / 2 0 2 2 1 : 2 9 : 2 4 P M A4-01 EL E V A T I O N S 12_33 LE O N A R D C H E N & L I Z L I U RE S I D E N C E 12-21-14 Author Checker 71 7 E S T R E L L A A V E , AR C A D I A , C A 9 1 0 0 7 1/4" = 1'-0"1 WEST 1/4" = 1'-0"2 SOUTH 1/4" = 1'-0"4 NORTH 1/4" = 1'-0"3 EAST No. Description Date 1 PLN REV 1 5/15/22 3 PLN REV 3 8/30/22 1st FF 0" 2ND FF 9' -0" GRADE -1' -6" EDB 2ND FC 17' -0" A 1st FC 8' -0" C ROOF 22' -0" (E) CEILING JOIST @16"OC (E) FLOOR JOIST @16"OC (E) FTG 476 SF LIVING 5 34 SF PANTRY 3 (N) WALL (N) FLOOR JOIST @16"OC (N) CEILING JOIST@16"OC F 86 SF CLOSET 9 1st FF 0" 2ND FF 9' -0" GRADE -1' -6" EDB 2ND FC 17' -0" 1st FC 8' -0" C ROOF 22' -0" (E) WALL200 SF KITCHEN 4 476 SF LIVING 5 104 SF G BATH. 6 68 SF MASTER BATH 8 (N) FLOOR JOIST @16"OC (E) FTG(E) FLOOR JOIST @16"OC (N) WALL (N) ROOF RAFTERS @16"OC F (N) FTG 1st FF 0" 2ND FF 9' -0" GRADE -1' -6" 2 3 4 2ND FC 17' -0" 1st FC 8' -0" 1 ROOF 22' -0" (E) CEILING JOIST @16"OC (E) FLOOR JOIST @16"OC(N) FLOOR JOIST @16"OC 476 SF LIVING 5 (N) FLOOR JOIST @16"OC (N) CEILING JOIST@16"OC (N) ROOF RAFTERS @16"OC 200 SF KITCHEN 4 68 SF MASTER BATH 8 68 SF LAUNDRY 10 LI C E N S E D ARCHIT E C T S T A T E OF C A L I F O RNINA MICHAEL SONG LIC.# C-32566 EXP: 12/31/21 Scale Project number Date Drawn by Checked by ARCHITECTURE DESIGN 821 Lime Ave Long Beach CA 90813 626.375.3073 Al l p l a n s , d e s i g n s , a r r a n g e m e n t s a n d i d e a s i n d i c a t e d o r r e p r e s e n t e d o n t h i s d r a w i n g s h e e t a r e " I n s t r u m e n t s o f S e r v i c e " a n d p r o p e r t y o f M A A r c h i t e c t s . A s s u c h , t h e y a r e i n t e n d e d f o r u s e s p e c i f i c a l l y o n t h i s p r o j e c t o n l y . N o n e o f th e p l a n s , d e s i g n s , a r r a n g e m e n t s o r i d e a s o f t h i s d r a w i n g s h e e t / s e t s h a l l b e u s e d , d i s c l o s e d , a l t e r e d , o r r e p r o d u c e d b y a n y p e r s o n , f i r m , o r c o r p o r a t i o n f o r a n y p u r p o s e w h a t s o e v e r w i t h o u t w r i t t e n p e r m i s s i o n o f M A A r c h i t e c t s . 1/4" = 1'-0" 9/ 1 5 / 2 0 2 2 3 : 5 7 : 0 7 P M A4-03 BU I L D I N G S E C T I O N S 12_33 LE O N A R D C H E N & L I Z L I U RE S I D E N C E 12-21-14 Author Checker 71 7 E S T R E L L A A V E , AR C A D I A , C A 9 1 0 0 7 1/4" = 1'-0"1 Section 1 1/4" = 1'-0"2 Section 2 1/4" = 1'-0"3 Section 3 No. Description Date