Loading...
HomeMy WebLinkAboutApproved PlansYI N R E S I D E N C E 22 1 9 S S A N T A A N I T A Ar c a d i a , C A 9 1 0 0 6 RE V I S I O N S DA T E IN F O @ S I L V E R E L M S . C O M o 6 2 6 2 3 4 2 3 5 4 c 5 1 0 8 6 3 0 3 4 1 71 3 W . D u a r t e R o a d # G 2 4 2 , A r c a d i a C A PR O J E C T I N F O R M A T I O N VB CONSTRUCTION TYPE ZONING r-1 ASSESSORY NUMBER 5788-010-004 713 W. DUARTE RD, UNIT G242 ARCADIA, CA 91007 DESIGNER CHRISTINA Y. FU SILVER ELM STUDIO LLC OWNER PROJECT INFORMATION PROJECT LOCATION PROJECT DESCRIPTION YIN RESIDENCE ARCADIA, CA 91006 2219 S SANTA ANITA DETAIL REFERENCE ROOM NAME EQUIPMENT NO. REVISION NO. WINDOW NO. DOOR NO. DATUM POINT TO BE REMOVED PROPERTY LINE HIDDEN, FUTURE, OR CENTER OR FLOOR LINE EXISTING CONSTRUCTION ROOM REFERENCE ELEVATION DOOR REFERENCE EQUIPMENT REFERENCE REVISION REFERENCE WINDOW REFERENCE SECTION NO. SHEET NO. SECTION NO. SHEET NO. SHEET NO. SECTION NO. SHEET NO. SECTION NO. REFERENCE WALL SECTION REFERENCE DETAIL REFERENCE BUILDING SECTION SYMBOLS Sunny and Conrad yin TITLE SHEETT1 PROPOSED EXTERIOR ELEVATIONSA4.1 678 SQUARE FEET ADDITION TO EXISTING2,340 SQUARE FEET SINGLE STORY SINGLE FAMILY RESIDENCE. ADDITION INCLUDES A NEW KITCHEN, NEW LAUNDRY ROOM, AND NEW DINING AREA. INTERIOR REMODEL OF THE EXISTING HOUSE TO INCLUDE 3 EXISTING BATHROOMS, AND CONVERTING THE EXISTING KITCHEN INTO A MUD-ROOM, AND CONVERTING THE EXISTING LAUNDRY INTO A POWDER ROOM. new cmu wall, connecting with the existing cmu wall, along the north property line. 510 863 0341 STRUCTURAL ENGINEER R-3 OCCUPANCY GROUP 2219 S SANTA ANITA ARCADIA, CA 91006 NO FIRE ZONE SHEET INDEX CODES THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODES: 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA ENERGY CODE (CEC) 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA MECHANICAL CODES (CMC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA GREEN BUILDING CODE (CALGREEN) ROOF PLANA3.1 LOT CALCULATION LOT SIZE: approx. 22,572 sq.ft. 45% maximum lot coverage: 10,157.4 square feet GENERAL NOTES VICINITY MAP THE GENERAL CONTRACTOR IS TO BE IN DIRECT CONTRACT WITH THE OWNER AND RESPONSIBLE FOR VERIFYING SITE CONDITION AND DIMENSION PRIOR TO START OF CONSTRUCTION. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE COST, MEANS AND METHOD OF THE WORK. SILVER ELM STUDIO IS NOT RESPONSIBLE FOR ANY ERRORS AND OMISSION OF THE INFORMATION AND WORK PROVIDED BY THE GENERAL CONTRACTOR. ANY INCONSISTENCIES AND AMBIGUITIES BETWEEN THE PLAN AND THE SITE CONDITION IS TO BE NOTIFIED TO SILVER ELM STUDIO WITHIN 7 DAYS OF DISCOVERY. IF NO NOTIFICATION IS PROVIDED AFTER 7 DAYS OF DISCOVERY, THE GENERAL CONTRACTOR IS RESPONSIBLE TO FOR RESOLVING THE SITUATION. existing sqft. house 1 HOUSE 2 addition / new sqft. 6,037 2,340 0 678 780 0 TOTAL LOT COVERAGE 8635,352 PROJECT LOCATION CALCIVIC ENGINEERING INC 2160 PARNELL WAY ALTADENA, CA 91001 626 798 2828 CALCIVIC@EARTHLINK.NET 22028 VENTURA BLVD. SUITE 207 WOODLAND HILLS, CA 91364 ENERGY ANALYSIS SOLARGY INC. 818 347 6096 RAFFI NORADOUKIAN, CEA EXISTING ROOF PLANSEX 3 EXISTING FLOOR PLAN AND GARAGEEX 2 FLOOR PLANA2.1 HOUSE 3 demolishED LOT COVERAGE sqft. covered patio total sqft. 0 625 (178)185 830 0 0 NOTES 2219 S SANTA ANITA ARCADIA, CA 91006 3018 632 830 GARAGE 408 0 780 total livable area 4,628 A6.1 A6.2 DOOR SCHEDULE AND DETAILS WINDOW SCHEDULE AND DETAILS A5.1 A5.2 SECTIONS SECTIONS E2.1 LIGHTING AND ELECTRICAL GENERAL NOTESGN1 2019 CALGREEN CHECK LIST AND TABLESGN2 2019 CALGREEN NOTESGN3 TITLE 24 - HOUSET24-1 TITLE 24 - HOUSET24-2 TITLE 24 - HOUSET24-3 STRUCTURAL ARCHITECTURAL A10.1 DETAILS ROOF PLANA3.2 A7.1 REFLECTIVE CEILING PLAN A8.1 FLOORING PLAN THE PROPERTY IS UNSPRINKLERED SINGLE FAMILY RESIDENCE USE EXISTING EXTERIOR ELEVATIONSEX4.1 PROPERTY BOUNDARY TRACT # 11119 N 76 FT OF LOT 3 CARPORT #1 CARPORT #2 0 408 00 00 161 208 161 208 (178) 3,950 6780 T1 Co n d i t i o n a l l y A p p r o v e d 10 / 2 4 / 2 0 2 3 DW K-3322-RAGABRIELLETOILETSVITREOUS CHINA K-3322-RAGABRIELLETOILETSVITREOUS CHINA K-3322-RAGABRIELLETOILETSVITREOUS CHINA LIVING ROOM ENTRY DINING ROOMFAMILY ROOM KITCHEN LAUNDRY HALLWAY BEDROOM #2 MASTER BEDROOM HALLWAY (e) BATHROOM #2 COVERED PATIO BATHROOM BEDROOM #4 BEDROOM #3 (e) Two car garage cARPORT (E) trellis 625.28 sqft 5' - 0 " 7' - 7 " 6' - 6 " 20 ' - 3 " 20'-2"22'-9"10'-11" 14 ' - 8 " 21'-3" 20 ' - 0 " 28'-71 2" 56 ' - 5 " 15'-2"40'-1" (E ) s e t b a c k (e) Basement entry (E ) s e t b a c k (E ) s e t b a c k (e) BATHROOM #1 19 ' - 2 " FAU basement YI N R E S I D E N C E 22 1 9 S S A N T A A N I T A Ar c a d i a , C A 9 1 0 0 6 RE V I S I O N S DA T E IN F O @ S I L V E R E L M S . C O M o 6 2 6 2 3 4 2 3 5 4 c 5 1 0 8 6 3 0 3 4 1 71 3 W . D u a r t e R o a d # G 2 4 2 , A r c a d i a C A EX I S T I N G F L O O R P L A N LEGEND exterior walls: 2x6 N SMOKE ALARM HARD WIRED WITH BATTERY BACK UP interconnected SMOKE / CARBON MONOXIDE DETECTOR HARD WIRED WITH BATTERY BACK UP interconnected interior walls: 2x4 BASEMENT GARAGE 6'0' 2'14'6'0' 2'14' SCALE: 1/4"= 1'-0"EX2.1 Co n d i t i o n a l l y A p p r o v e d 10 / 2 4 / 2 0 2 3 CH I M N E Y SLOPE 5:12 SLOPE 5:12 SL O P E 5: 1 2 SL O P E 5: 1 2 SLOPE 5:12 SL O P E 1: 1 2 SL O P E 2: 1 2 SL O P E 4: 1 2 SL O P E 4: 1 2 SLOPE 5:12 SL O P E 5: 1 2 SLOPE 5:12 SL O P E 5: 1 2 SLOPE 1.5:12 trellis (e) ridge slope change covered patio rooF co v e r e d p a t i o r o o f (e ) r i d g e hip h i p h i p hip va l l e y h i p hip (e ) r i d g e hip h i p hip hip h i p h i p v a l l e y EX I S T I N G R O O F P L A N S YI N R E S I D E N C E 22 1 9 S S A N T A A N I T A Ar c a d i a , C A 9 1 0 0 6 RE V I S I O N S DA T E IN F O @ S I L V E R E L M S . C O M o 6 2 6 2 3 4 2 3 5 4 c 5 1 0 8 6 3 0 3 4 1 71 3 W . D u a r t e R o a d # G 2 4 2 , A r c a d i a C A 6'0' 2'14'6'0' 2'14' SCALE: 1/4"= 1'-0" N EX3.1 Co n d i t i o n a l l y Ap p r o v e d 10 / 2 4 / 2 0 2 3 A EXISTING EAST composite shingles stucco B EXISTING NORTH 1ST FLOOR FFL composite shingles stucco 15 ' - 1 1 12" + / - (E ) b u i l d i n g h e i g h t composite shingles stucco carport roof C EXISTING WEST composite shingles stucco (E) porch roof D EXISTING SOUTH composite shingles stucco carport roof composite shingles stucco (E) porch roof EX I S T I N G E X T E R I O R E L E V A T I O N S 6'0' 2'14'6'0' 2'14' SCALE: 1/4"= 1'-0"EX4.1 2/ 1 4 / 2 0 1 9 7/ 1 1 / 2 0 1 9 YI N R E S I D E N C E 22 1 9 S S A N T A A N I T A Ar c a d i a , C A 9 1 0 0 6 RE V I S I O N S DA T E IN F O @ S I L V E R E L M S . C O M o 6 2 6 2 3 4 2 3 5 4 c 5 1 0 8 6 3 0 3 4 1 71 3 W . D u a r t e R o a d # G 2 4 2 , A r c a d i a C A Co n d i t i o n a l l y Ap p r o v e d 10 / 2 4 / 2 0 2 3 LANDSCAPED (e) DRIVEWAY (e) 2 car GARAGE PR O P E R T Y L I N E 7 6 ' PROPERTY LINE 297' ELECTRIC METER PROPERTY LINE 297' PR O P E R T Y L I N E 7 6 ' Assessor's ID No:5788-010-004 Address: 2219 S SANTA ANITA AVE ARCADIA CA 91006 Property Boundary Description TRACT # 11119 N 76 FT OF LOT 3 EXISTING SINGLE FAMILY DWELLINGexisting house 3 836 sqft SINGLE FAMILY DWELLING EXISTING house 2 780 sqft SINGLE FAMILY DWELLING (e) DRIVEWAY (e) carport (e) trellis (e) covered patio (e) carport 7' - 7 " 5' - 0 " CONCRETE PATIO CONCRETE PATIO CONCRETE PATIO PATIO (e) cum block (e) cum block (e) MINI SPLIT AC5' - 1 1 " (e) AC 408 sqft161 sqft208 sqft 2,340 sqft ex i s t i n g f e n c e existing fence 625 sqft 222 sqft fruit tree orange tree (e) wood fence LANDSCAPED (e) DRIVEWAY (e) 2 car GARAGE PR O P E R T Y L I N E 7 6 ' PROPERTY LINE 297' ELECTRIC METER PROPERTY LINE 297' PR O P E R T Y L I N E 7 6 ' Assessor's ID No:5788-010-004 Address: 2219 S SANTA ANITA AVE ARCADIA CA 91006 Property Boundary Description TRACT # 11119 N 76 FT OF LOT 3 EXISTING SINGLE FAMILY DWELLING (e) DRIVEWAY (e) carport (e) covered patio (e) carport 7' - 7 " 5' - 0 " CONCRETE PATIO CONCRETE PATIO CONCRETE PATIO PATIO (e) cum wall (e) cum wall 678 sqft addition 6' - 3 " 7' - 7 " (E ) S E T B A C K (E ) S E T B A C K ad d i t i o n SE T B A C K (E ) S E T B A C K 56'-014" 2'-01 2" 52'-6" 52'-6" EXISTING MINI SPLIT AC 5' - 1 1 " existing house 3 836 sqft SINGLE FAMILY DWELLING EXISTING house 2 780 sqft SINGLE FAMILY DWELLING ex i s t i n g f e n c e existing fence 408 sqft161 sqft208 sqft 451 sqft 7' - 7 " 3'-9" 2215 front setback 2221 front setback existing front setback 54'-4" new porch front setback EXISTING covered porch new covered porch 69 sqft. ne w p o r c h SE T B A C K (e) covered landing, 79 sqft relocate ac (e) orange tree 99'-6" new cmu wall to replace existing wood fence (e) cum wall SI T E P L A N 0'12'0' 4'28' SCALE: 3/32"= 1'-0" N A1.1 YI N R E S I D E N C E 22 1 9 S S A N T A A N I T A Ar c a d i a , C A 9 1 0 0 6 RE V I S I O N S DA T E IN F O @ S I L V E R E L M S . C O M o 6 2 6 2 3 4 2 3 5 4 c 5 1 0 8 6 3 0 3 4 1 71 3 W . D u a r t e R o a d # G 2 4 2 , A r c a d i a C A 0'12'0' 4'28' SCALE: 3/32"= 1'-0" N Co n d i t i o n a l l y A p p r o v e d 10 / 2 4 / 2 0 2 3 UNDER-FLOOR VENT CALCULATION FOR 678 sqft crawl space area 678 sq.ft. (1/150) = ---- sq.ft. ---- SQ.FT. X 144 = ---- SQ.IN. average CRAWL SPACE VENT 16"X8" INCHES = 128 SQ.IN. ---- SQ.IN. / 128 sq.in. = 6.68 provide 7 new under floor vents SYMBOL DENOTES LOCATION OF VENTS vent openings in exterior walls shall resist the intrusion of flame and ember into the structure or vents shall be screened with a corrosion-resistant, non-cumbustalbe wire mesh with 1/4 inch (6mm) openings or its equivalent. (cbc 704.3.2.1) ALL NEW LAVATORY FAUCETS, SHOWER HEADS AND TOILETS SHALL COMPLY WITH THE PROVISIONS OF CALIFORNIA GREEN BUILDING STANDARDS CODE REDUCTION AS FOLLOWS: single SHOWER HEADS:MAX. 1.8 GPM @ 80 PSI When a shower is served by more than one showerhead, the combined flow rate of all the showerheads controlled by a single valve shall not exceed 2gpm @ 80 psi or the shower shall be designed to only allow one showerhead to be in operation at a time. LAVATORY FAUCETS: MAX. 1.2 GPM @ 60 PSI The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gpm @20 psi TOILETS:MAX. 1.28 GAL PER FLUSH KITCHEN FAUCETS: MAX. 1.8 GPM @ 60 PSI Kitchen faucets may temporarily increase the flow above the flow above the maximum rate, but not to exceed 2.2 gpm @ 60 psi. STANDARDS FOR PLUMBING FIXTURES AND FITTINGS: PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH CALIFORNIA PLUMBING CODE, AND SHALL MEET THE APPLICABLE STANDARDS REFERENCED IN TABLE 1401.1 OF CALIFORNIA PLUMBING CODE. CALGREEN NOTES UNDER-FLOOR VENT CALCULATION w9 d1 K-3322-RAGABRIELLE T O I L E T S VITREOUS CHINA K-3322-RAGABRIELLETOILETSVITREOUS CHINA K-3322-RAGABRIELLETOILETSVITREOUS CHINA K-3322-RAGABRIELLETOILETSVITREOUS CHINA K-3322-RAGABRIELLETOILETSVITREOUS CHINA LIVING ROOM ENTRy #1 (re) office (n) mudroom (n) powder room HALLWAY #1 (e) BEDROOM #2 (re) MASTER BEDROOM HALLWAY #2 COVERED PATIO (re) BATHROOM #1 (e) BATHROOM (re) BEDROOM #4 (re) BEDROOM #3 garage cARPORT (n) kitchen (n) powder room (n) laundry (re) BATHROOM #2 22'-9" 7'-3"11'-11"2'-8" (re) family room(n) dining (re) office solar tube solar tube cabinets closet sh e l v e s washer & dryer under cabinet with storage cabinets above dw. 36" sink sink 8' - 0 " 12 ' - 5 " 5' - 8 1 2" 10'-6" 9'-4"27'-412" 14 ' - 8 " 37'-912" new porch cover ENTRY #2 7'-11" 5'-21 2"7'-6" 36 " fr i d g e 5' - 1 1 " broom closet cl o s e t pa n t r y 36" range & hood 16'-61 2" addition 21'-3" existing covered landing sink cabinets addition 17'-112" ad d i t i o n 7' - 7 " 5' - 0 " 5' - 0 " 10 ' - 0 " lower cabinet d13 d9 d12 d3 d4 d7 d2 d8 d10 d5 d14w3w2 w1 w4 w6 w5 w7 w8 d6 3'-0" 3'-1112"4'-0"3'-1112"10"2'-8"2'-8"10" 2'-2"6'-0"11" 4'-0" 8'-0" 6' - 0 " 1'-8"6'-0"1'-8"6'-6"14'-7"6'-0"4" 2'-0" 4'-4"2'-11" 5' - 0 " 3'-111 2"4'-0" 9"4'-0" 4" 8' - 0 " 3' - 0 " 2' - 8 " cabinets d16 d15 d11 7' - 7 " 3'-9" 18 ' - 5 " YI N R E S I D E N C E 22 1 9 S S A N T A A N I T A Ar c a d i a , C A 9 1 0 0 6 RE V I S I O N S DA T E IN F O @ S I L V E R E L M S . C O M o 6 2 6 2 3 4 2 3 5 4 c 5 1 0 8 6 3 0 3 4 1 71 3 W . D u a r t e R o a d # G 2 4 2 , A r c a d i a C A NE W F L O O R P L A N N LEGEND exterior walls: 2x6 SMOKE ALARM HARD WIRED WITH BATTERY BACK UP interconnected SMOKE / CARBON MONOXIDE DETECTOR HARD WIRED WITH BATTERY BACK UP interconnected interior walls: 2x4 existing wall 6'0' 2'14'6'0' 2'14' SCALE: 1/4"= 1'-0"A2.1 Co n d i t i o n a l l y Ap p r o v e d 10 / 2 4 / 2 0 2 3 "O'HAGIN PRIMARY VENT" FLAT STYLE NET FREE VENT AREA = 98.75 SQ.IN. 14"x5" galvanized eave soffit vent = 70 sq.in. LEGEND EXISTING PERIMETER WALL NEW PERIMETER WALLS new roof CALCULATION 678 (1/150) = 4.52 SQ.FT 4.52 SQ.FT(144 SQ.IN) = 650.88 SQ.IN REQ. VENTILATION = 650.88 SQ.IN. min. 50% roof vent = 325.44 sq.in. max. 50% eave soffit vent = 325.44 sq.in. O'HAGIN roof vent: 325.44 / 98.75 = 3.296 4 X 98.75 = 395 SQ.IN. provided (4 vents) eave soffit vent: 678 - 395 = 373 sq.in. required. 283 / 70 = 4.043 5 x 70 = 350 sq.in. provided (5 vents) minimum vents provided = 395 + 350 = 745 sq.in. HOUSE ADDITION 14"x5" galvanized eave soffit vent = 70 sq.in. "O'HAGIN PRIMARY VENT" FLAT STYLE NET FREE VENT AREA = 98.75 SQ.IN. ROOF MATERIAL new roof to match existing composite shingles ATTIC VENTILATION area of house addition SLOPE 5:12 SLOPE 5:12 SL O P E 5: 1 2 SL O P E 5: 1 2 SLOPE 5:12 SL O P E 1: 1 2 SL O P E 2: 1 2 SL O P E 4: 1 2 SL O P E 4: 1 2 SL O P E 4: 1 2 SL O P E 4: 1 2 SL O P E 1: 1 2 SL O P E 4: 1 2 SL O P E 4: 1 2 SL O P E 4: 1 2 SL O P E 4: 1 2 SL O P E 4: 1 2 SL O P E 4: 1 2 SL O P E 4: 1 2 SLOPE 5:12 SLOPE 5:12 SL O P E 4: 1 2 SL O P E 4: 1 2 SLOPE 5:12 SL O P E 4: 1 2 SLOPE 1/2:12 SL O P E 5: 1 2 SLOPE 5:12 SLOPE 1/2:12 cricket roof (E ) v a l l e y (E ) h i p (E ) h i p (E ) h i p (E) hip (E ) r i D g e (E ) h i p (E ) r i D g e (E ) v a l l e y (E) hip ( E ) v a l l e y (E ) r i D g e (E) riDge(E) riDge(N) riDge (N) riDge (e) garage carport (e) covered porch (E) hip (N) Front porch roof YI N R E S I D E N C E 22 1 9 S S A N T A A N I T A Ar c a d i a , C A 9 1 0 0 6 RE V I S I O N S DA T E IN F O @ S I L V E R E L M S . C O M o 6 2 6 2 3 4 2 3 5 4 c 5 1 0 8 6 3 0 3 4 1 71 3 W . D u a r t e R o a d # G 2 4 2 , A r c a d i a C A NE W R O O F P L A N 6'0' 2'14'6'0' 2'14' SCALE: 1/4"= 1'-0" A3.1 N Co n d i t i o n a l l y Ap p r o v e d 10 / 2 4 / 2 0 2 3 A PROPOSED EAST (e) Roof (N) front porch roof (e) stucco 1ST FLOOR FFL B PROPOSED NORTH 22'-9" addition (E) Roof (N) Roof (N) Roof (N) Roof (E) Roof d3W5 W7W8 (E) stucco (N) stucco (E) stucco (E) carport roof (n) covered porch landing (n) covered porch roof D PROPOSED SOUTH (E) Roof (N) Roof (N) Roof (N) Roof (E) Roof (E) Roof W6 W4 W2 w3 d1 (E) covered porch (E) stucco(N) stucco C PROPOSED WEST 19'-2" (N) Roof (E) porch Roof d2 W1 W9d5 addition (N) Covered walkway (E) STUCCO(N) STUCCO NE W E X T E R I O R E L E V A T I O N S 6'0' 2'14'6'0' 2'14' SCALE: 1/4"= 1'-0"A4.1 2/ 1 4 / 2 0 1 9 7/ 1 1 / 2 0 1 9 YI N R E S I D E N C E 22 1 9 S S A N T A A N I T A Ar c a d i a , C A 9 1 0 0 6 RE V I S I O N S DA T E IN F O @ S I L V E R E L M S . C O M o 6 2 6 2 3 4 2 3 5 4 c 5 1 0 8 6 3 0 3 4 1 71 3 W . D u a r t e R o a d # G 2 4 2 , A r c a d i a C A Co n d i t i o n a l l y A p p r o v e d 10 / 2 4 / 2 0 2 3