HomeMy WebLinkAboutApproved PlansASSESSOR MAP
REVISION TAG
SECTION CALLOUT
DETAIL SYMBOL
ELEVATION CALLOUT
DETAIL BOUNDARY
DOOR TYPE
ROOM IDENTIFICATION
WINDOW TAG
LEVEL INDICATOR
KEYNOTE TAG CEILING TAG
CEILING FINISH TAG
FLOOR FINISH TAG
WALL FINISH TAG
FF&E TAG
A.F.F ABOVE FINISHED FLOOR
APPROX APPROXIMATELY
B.O.H.BACK OF HOUSE/STORAGE
CUST.CUSTOM
DIA. DIAMETER
DIST. DISTRIBUTOR
(E)EXISTING
ELEC ELECTRICAL
ELEV. ELEVATION
EQ.EQUAL
E EQUIPMENT
(E) EXISTING TO REMAIN
F.A.FINISH FLOOR
FF&E FURNITURE, FIXTURE, & EQUIPMENT
FIN. FINISHED
FIXT. FIXTURE
FL FLOOR
NOTES AND ABBREVIATIONS
SYMBOLS AND TAGS PROJECT INFORMATION DRAWING SHEET INDEX
SCOPE OF WORK:INTERIOR REMODEL OF (E) SINGLE FAMILY
RESIDENCE INCLUDING CHANGES TO
INTERIOR STRUCTURAL WALLS. REMODEL
INCLUDES ADDING NEW ROOF AND NEW
COVERED OUTDOOR PATIO AREA AND
FACADE IMPROVEMENTS. ADDITION OF
POOL BATH AND AREA FROM (E) GARAGE.
TOTAL ADDITION AT 188 SQ. FT.
PROJECT LOCATION:
OWNER:
ARCHITECT:
ALL WORK SHALL BE IN CONFORMANCE WITH, BUT NOT LIMITED TO, THE
REQUIREMENTS OF THE CALIFORNIA AND LOCAL CITY CODES HAVING
JURISDICTION.
NATALIE KAZANJIAN ARCHITECT, INC.
1204 DON JOSE DRIVE
GLENDALE, CA 91207
310.748.9218
MISCELLANEOUS NOTES:
OWNERS'S GENERAL CONTRACTOR SHALL VISIT THE PREMISES AND
VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION
AND SHALL REPORT ALL DISCREPANCIES TO OWNER'S ARCHITECT.
OWNER'S GENERAL CONTRACTOR SHALL CONFORM TO ALL
REQUIREMENTS REGARDING CONSTRUCTION PROCEDURES, INSURANCE,
ETC.
OCCUPANCY:
1330 RODEO RD.
ARCADIA, CA 91006
R-0 (30,000)
5770-006-018
10955
81
ZONING DISTRICT:
ACCESSOR'S ID:
TRACT:
LOT:
LEGAL DESCRIPTION:
G.C.GENERAL CONTRACTOR
GEN GENERAL
GL GLASS
GYP. GYPSUM BOARD
HDW HARDWARE
KE KEEP EXISTING
MOD.D.MODULAR
MR MIRROR
MW MILLWORK
N.I.C. NOT IN CONTRACT
O.C ON CENTER
O.D. OUTSIDE DIAMETER
PT PAINT
PL PLASTER
P PLUMBING FIXTURE
R RADIUS
RM ROOM
SS SOLID SURFACE
STD STANDARD
STP SPECIAL PAINT
ST STONE
TL TILE
T.O.S TOP OF SLAB
T,B,D,TO BE DETERMINED
(TYP)TYPICAL OR THROUGHOUT
U/S UNDER SIDE
UC UNDER COUNTER
V.I.F VERIFY IN FIELD
WP WALLPAPER
W/ WITH
W.C. WATER CLOSET
WD WOOD
ARCADIA, CALIFORNIA 91006
EXISTING WALL
NEW WALL
DEMO WALL
BUILDING CODES: THIS PROJECT SHALL COMPLY WITH THE 2019 EDITION
OF THE CALIFORNIA BUILDING CODE (CBC) WITH THE 2020 CALIFORNIA
GREEN BUILDING CODE AND CITY OF ARCADIA AMENDMENTS.
CALIFORNIA RESIDENTIAL CODE (2019) EDITION
CALIFORNIA BUILDING CODE (2019) EDITION
CALIFORNIA PLUMBING CODE (2019) EDITION
CALIFORNIA MECHANICAL CODE (2019) EDITION
CALIFORNIA ELECTRICAL CODE (2019) EDITION
CALIFORNIA ENERGY AND RESIDENTIAL CODES (2019 EDITION)
CALIFORNIA GREEN CODE (2020)
R-3
AREA CALCULATIONS:
LOT SIZE:35,062.0 SQ. FT.
(E) RESIDENCE:5,551.0 SQ. FT.
TOTAL PROPOSED:
TOTAL GARAGE:
TOTAL GUEST/ADU HOUSE (ADU UNDER
SEPARATE PERMIT):
5,660 SQ. FT.
CONSULTANTS:
CONSTRUCTION TYPE:
NUMBER OF STORIES:
NUMBER OF BUILDINGS: 1
NUMBER OF UNITS:
TYPE V-B
VICINITY MAP
DESIGN REQUIREMENTS:
HILLSIDE AREA:NO
SPECIFIC PLAN AREA: NO
VERY HIGH FIRE HAZARD SEVERITY ZONE: NO
HISTORIC PRESERVATION REVIEW NO
GOVERNING CODES:
LOT COVERAGE (INCLUDING GARAGE):20 %
F.A.R.(FLOOR AREA RATI0).197
1330 RODEO ROAD
ADDITION - FROM (E) GARAGE AND POOL BATH 188 SQ. FT.
ARCHITECTURAL
A-0.0 PROJECT DATA / INDEX SHEET
A-0.1 GENERAL NOTES
A-1.0 SITE PLAN
L-1 LANDSCAPE PLAN
A-1.1 DEMO PLAN
A-1.2 EXISTING BUILDING ELEVATIONS
A-2.0 PROPOSED FLOOR PLAN
A-2.1 ROOF PLAN
A-4.0 BUILDING ELEVATIONS
A-4.1 BUILDING ELEVATIONS
A-4.2 BUILDING SECTIONS
A-5.0 DOOR SCHEDULE
A-5.1 WINDOW SCHEDULE
EXISTING - 1 SFD w/ ATTACHED GARAGE AND ADU
PROPOSED - (E) TO REMAIN
PLOT PLAN
1-STORY
1330 RODEO RD.
ARCADIA, CA 91006
SINGLE FAMILY RESIDENCE REMODEL
JIE HE AND KATHERINE MANWAI
(E) GARAGE:764 SQ. FT.
655 SQ. FT.
(E) GUEST HOUSE:600 SQ. FT.
600 SQ. FT.
LANDSCAPE ARCHITECT:LANDSHAPE INC.
9 OAKMONT, TRABUCO CANYON
COTO DE CAZA, CALIFORNIA 92679
MARK GENNARO
714.915.0696
A-0.0
PROJECT LOCATION SITE LOCATION
N A T A L I E
K A Z A N J I A N
A R C H I T E C T
1 2 0 4 D O N J O S E D R I V E
G L E N D A L E , C A 9 1 2 0 7
T : 3 1 0 .7 4 8 .9 2 1 8
i n f o @ n a t a l i e k a z a n j i a n .c o m
n a t a l i e k a z a n j i a n .c o m
1330 RODEO ROAD
JIE HE AND KATHERINE MANWAI
ARCADIA, CALIFORNIA 91006
NA
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
E
X
P
R
E
S
S
L
Y
R
E
S
E
R
V
E
S
I
T
S
C
O
M
M
O
N
L
A
W
C
O
P
Y
R
I
G
H
T
A
N
D
O
T
H
E
R
P
R
O
P
E
R
T
Y
R
I
G
H
T
S
I
N
T
H
E
S
E
P
L
A
N
S
.
T
H
E
S
E
P
L
A
N
S
A
R
E
N
O
T
T
O
B
E
R
E
P
R
O
D
U
C
E
D
,
C
H
A
N
G
E
D
O
R
C
O
P
I
E
D
I
N
A
N
Y
F
O
R
M
O
R
M
A
N
N
E
R
W
H
A
T
S
O
E
V
E
R
,
N
O
R
A
R
E
T
H
E
Y
T
O
B
E
A
S
S
I
G
N
E
D
T
O
A
T
H
I
R
D
P
A
R
T
Y
W
I
T
H
O
U
T
F
I
R
S
T
O
B
T
A
I
N
I
N
G
T
H
E
E
X
P
R
E
S
S
W
R
I
T
T
E
N
P
E
R
M
I
S
S
I
O
N
A
N
D
C
O
N
S
E
N
T
O
F
N
A
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
.
OWNER:
PROJECT:
RESIDENTIAL REMODEL
1330 RODEO ROAD
ARCADIA, CALIFORNIA 91006
PROPERTY LINE 138.67'
PR
O
P
E
R
T
Y
L
I
N
E
8
7
.
0
5
'
PR
O
P
E
R
T
Y
L
I
N
E
3
2
.
5
1
'
PR
O
P
E
R
T
Y
L
I
N
E
1
8
.
2
5
'
PROPERTY LINE 141.25'
PR
O
P
E
R
T
Y
L
I
N
E
1
0
5
.
0
0
'
1330 RODEO RD.
ARCADIA, CA 91006
LOT 81
TRACT 10955
(E) SINGLE-FAMILY
RESIDENCE
(E) ATRIUM
(N) WALKWAY
(E) 6FT CMU WALL
(E) SWIMMING POOL
(E) ELEC.
PANEL/
METER
(E) POOL EQUIPMENT
(E) GAS
(E) LANDSCAPING
(E) DRIVEWAY
(E) HEDGES
(E) ELEC.
POST
(E) LANDSCAPING
(E) STONE PAVING
RESIDENCE
1328 RODEO RD.
ARCADIA, CA 901006
LOT 80
TRACT 10955
RESIDENCE
(E) 6FT CMU WALL
(E) BASKETBALL COURT
1325 RAMONA RD.
ARCADIA, CA 901006
LOT 58
TRACT 11074
(E) SINGLE-FAMILY
(E) SINGLE-FAMILY
LINE OF (E) RESIDENCE FOOTPRINT TO REMAIN
30'-
0
"
(N)COVERED
PATIO
11
'
-
4
"
12
'
-
6
"
55'-0"
85'-11"
(N)REAR YARD SET
101'-3"
(N)REAR YARD SET
(E)FRONT YARD SET TO REMAIN
(N)FRONT YARD SET TO ROOF EAVE
(E
)
S
I
D
E
Y
A
R
D
SE
T
B
A
C
K
(N
)
S
I
D
E
Y
A
R
D
SE
T
B
A
C
K
19
'
-
3
"
(E
)
SI
D
E
Y
A
R
D
S
E
T
(E
)
SI
D
E
Y
A
R
D
S
E
T
(N
)
SI
D
E
Y
A
R
D
S
E
T
TO
A
D
D
I
T
I
O
N
79 SQ. FT. ADDITION
(POOL BATHROOM)
109 SQ. FT. ADDITION OF
HABITABLE SPACE INTO
GARAGE
(E) GARAGE TO REMAIN
(E) GUEST HOUSE
CONVERSION TO ADU
(UNDER SEPARATE PERMIT)
(N
)
SI
D
E
Y
A
R
D
S
E
T
TO
R
O
O
F
(E) LANDSCAPING
30
'
-
0
"
18
'
-
6
1 2"
25
'
-
4
"
30
'
-
1
1 2"
80'-3"
54'-0"
SCALE: 3/32' = 1'-0"PROPOSED SITE PLAN 1
N A T A L I E
K A Z A N J I A N
A R C H I T E C T
1 2 0 4 D O N J O S E D R I V E
G L E N D A L E , C A 9 1 2 0 7
T : 3 1 0 .7 4 8 .9 2 1 8
i n f o @ n a t a l i e k a z a n j i a n .c o m
n a t a l i e k a z a n j i a n .c o m
1330 RODEO ROAD
JIE HE AND KATHERINE MANWAI
ARCADIA, CALIFORNIA 91006
NA
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
E
X
P
R
E
S
S
L
Y
R
E
S
E
R
V
E
S
I
T
S
C
O
M
M
O
N
L
A
W
C
O
P
Y
R
I
G
H
T
A
N
D
O
T
H
E
R
P
R
O
P
E
R
T
Y
R
I
G
H
T
S
I
N
T
H
E
S
E
P
L
A
N
S
.
T
H
E
S
E
P
L
A
N
S
A
R
E
N
O
T
T
O
B
E
R
E
P
R
O
D
U
C
E
D
,
C
H
A
N
G
E
D
O
R
C
O
P
I
E
D
I
N
A
N
Y
F
O
R
M
O
R
M
A
N
N
E
R
W
H
A
T
S
O
E
V
E
R
,
N
O
R
A
R
E
T
H
E
Y
T
O
B
E
A
S
S
I
G
N
E
D
T
O
A
T
H
I
R
D
P
A
R
T
Y
W
I
T
H
O
U
T
F
I
R
S
T
O
B
T
A
I
N
I
N
G
T
H
E
E
X
P
R
E
S
S
W
R
I
T
T
E
N
P
E
R
M
I
S
S
I
O
N
A
N
D
C
O
N
S
E
N
T
O
F
N
A
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
.
OWNER:
PROJECT:
RESIDENTIAL REMODEL
1330 RODEO ROAD
ARCADIA, CALIFORNIA 91006
A-1.0
SITE PLAN
SCALE: 3/32' = 1'-0"EXISTING SITE PLAN 1
6'-0" X 3'-0"
H.S.
3'
-
0
"
X
1
'
-
6
"
H.
S
.
6'
-
0
"
X
4
'
-
0
"
H.
S
.
CLG: 8'-0"
BEDROOM 5
CLG: 8'-0"
BEDROOM 3
CLG: 8'-0"
CLG: 8'-0"
CLG: 8'-0"
CLOSET
CLG: 8'-0"
CLOSET
CLOSET
CAB BUILT-IN
STORAGE
3'-0" X 6'-0"
S.H.
3'-0" X 6'-0"
S.H.
2'
-
6
"
X
1
'
-
6
"
H.
S
.
6'-0" X 3'-0"
H.S.
BEDROOM 2
CLOSET
CLG: 9'-0"
DEN
CLG: 8'-0"
BEDROOM 1
BEDROOM 4
CLG: 8'-0"
BEDROOM 6
CLG: 8'-0"
BATH
CLOSET
CLOSET
CLOSET
BEDROOM 7/
OFFICE
BATH
CLG: 8'-0"
COURTYARD
6'-0" X 3'-0"
H.S.
6'-0" X 3'-0"
H.S.
CLOSET
CLOSET
POWDER
CLOSET
BATH
CLG: 8'-0"
4'-0" X 3'-0"
H.S.
CLOSET
CLG: 9'-8"
DINING ROOM
SO
F
F
I
T
A
B
O
V
E
@
7
'
-
8
"
FOYER
SO
F
F
I
T
A
B
O
V
E
@
7
'
-
8
"
BUILT-IN
STORAGE
CLG: 11'-9"
6'
-
0
"
X
7
'
-
8
"
FI
X
E
D
2'
-
0
"
X
6
'
-
0
"
FI
X
E
D
2'
-
0
"
X
6
'
-
0
"
FI
X
E
D
2'
-
8
"
X
6
'
-
0
"
FI
X
E
D
DROP CLG: 7'-5"
GARAGE
VAULTED CEILING
FAMILY ROOM
KITCHEN
CLG: 8'-0"
TRACE OF SKYLIGHT ABOVE
TRACE OF
SKYLIGHT ABOVE
ATTIC ACCESS
6'-0" X 4'-0"
H.S.
LAUNDRY
PANTRY
KITCHEN
6'-0" X 5'-0"
H.S.
LIVING ROOM
CLG: 10'-9"
TR
A
C
E
O
F
S
K
Y
L
I
G
H
T
A
B
O
V
E
2'
-
1
0
"
X
6
'
-
0
"
FI
X
E
D
2'
-
1
0
"
X
6
'
-
0
"
FI
X
E
D
UP
1
2
"
6'
-
0
"
X
7
'
-
8
"
FI
X
E
D
4'-0" X 6'-6"
FIXED
4'-0" X 6'-6"
FIXED
FU
L
L
H
E
I
G
H
T
FI
X
E
D
1
A1.2
3
A1.2
TR
A
C
E
O
F
SK
Y
L
I
G
H
T
A
B
O
V
E
3'-0" X 7'-8"
2
A1.2
10'-0" X 7'-8"
DINING
12'-0" X 7'-8"
2'-4" X 6'-8"
6'
-
0
"
X
7
'
-
8
"
CLOSET
6'-0" X 6'-8"
(2
)
6'
-
0
"
X
6
'
-
8
"
6'
-
0
"
X
6
'
-
8
"
3'
-
0
"
X
6
'
-
8
"
3'-0" X 7'-8"
BE
A
M
A
B
O
V
E
3'-0" X 4'-0"
H.S.
TRACE OF DROP CEILING @ 8'-0" HIGH
GUEST HOUSE
CLG: 9'-0"
BEDROOM
CLG: 9'-0"
CLG: 8'-0"
BATH
6'-0" X 5'-0"
H.S.
EL
E
C
.
P
A
N
E
L
6'
-
0
"
X
8
'
-
0
"
DB
L
D
R
TR
A
C
E
O
F
SK
Y
L
I
G
H
T
A
B
O
V
E
FU
L
L
H
E
I
G
H
T
FI
X
E
D
3'-0" X 7'-8"
4
A1.2
2'-9" X 7'-8"
FIXED
2'-8" X 6'-8"
3'-0" X 7'-8"
(2)6'-0" X 7'-8"
2'-9" X 7'-8"
FIXED
3'-8" X 6'-0"
FIXED
UP 9"
UP 9"
BATH
CLG: 8'-0"
SCALE: 1/4' = 1'-0"DEMO PLAN 1
N A T A L I E
K A Z A N J I A N
A R C H I T E C T
1 2 0 4 D O N J O S E D R I V E
G L E N D A L E , C A 9 1 2 0 7
T : 3 1 0 .7 4 8 .9 2 1 8
i n f o @ n a t a l i e k a z a n j i a n .c o m
n a t a l i e k a z a n j i a n .c o m
1330 RODEO ROAD
JIE HE AND KATHERINE MANWAI
ARCADIA, CALIFORNIA 91006
NA
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
E
X
P
R
E
S
S
L
Y
R
E
S
E
R
V
E
S
I
T
S
C
O
M
M
O
N
L
A
W
C
O
P
Y
R
I
G
H
T
A
N
D
O
T
H
E
R
P
R
O
P
E
R
T
Y
R
I
G
H
T
S
I
N
T
H
E
S
E
P
L
A
N
S
.
T
H
E
S
E
P
L
A
N
S
A
R
E
N
O
T
T
O
B
E
R
E
P
R
O
D
U
C
E
D
,
C
H
A
N
G
E
D
O
R
C
O
P
I
E
D
I
N
A
N
Y
F
O
R
M
O
R
M
A
N
N
E
R
W
H
A
T
S
O
E
V
E
R
,
N
O
R
A
R
E
T
H
E
Y
T
O
B
E
A
S
S
I
G
N
E
D
T
O
A
T
H
I
R
D
P
A
R
T
Y
W
I
T
H
O
U
T
F
I
R
S
T
O
B
T
A
I
N
I
N
G
T
H
E
E
X
P
R
E
S
S
W
R
I
T
T
E
N
P
E
R
M
I
S
S
I
O
N
A
N
D
C
O
N
S
E
N
T
O
F
N
A
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
.
OWNER:
PROJECT:
RESIDENTIAL REMODEL
1330 RODEO ROAD
ARCADIA, CALIFORNIA 91006
A-1.1
DEMO PLAN
EXISTING TYP. RAISED FOUNDATION FLOOR TO REMAIN
EXISTING INTERIOR WALLS TO BE REMOVED
EXISTING EXTERIOR WALL TO BE REMOVED
EXISTING BATHROOM TO BE REMOVED
EXISTING DOOR TO BE REMOVED
EXISTING WINDOW TO BE REMOVED
LEGEND 2
EXISTING DOOR TO REMAIN
EXISTING DOOR TO BE REMOVED
EXISTING WALL, PATCH AND REPAIR WHERE
DAMAGED
EXISTING WALL TO BE REMOVED
KEYNOTES 3
(E) STUCCO (E) STUCCO (E) STUCCO (E) STUCCO
FINISH FLOOR
1'-0"
CEILING PLATE
9'-0"
CEILING PLATE
11'-0"
TOP OF PARAPET
16' - 0"
(E) STUCCO (E) STUCCO
FINISH FLOOR
1'-0"
CEILING PLATE
11'-0"
CEILING PLATE
9'-0"
TOP OF PARAPET
16' - 0"
(E) STUCCO
FINISH FLOOR
1'-0"
CEILING PLATE
11'-0"
CEILING PLATE
9'-0"
TOP OF PARAPET
16' - 0"
(E) STUCCO(E) STUCCO(E) STUCCO
(E) STUCCO (E) STUCCO
FINISH FLOOR
1'-0"
CEILING PLATE
9'-0"
CEILING PLATE
11'-0"
TOP OF PARAPET
16' - 0"
EXISTING BUILDING
ELEVATIONS
A-1.2
N A T A L I E
K A Z A N J I A N
A R C H I T E C T
1 2 0 4 D O N J O S E D R I V E
G L E N D A L E , C A 9 1 2 0 7
T : 3 1 0 .7 4 8 .9 2 1 8
i n f o @ n a t a l i e k a z a n j i a n .c o m
n a t a l i e k a z a n j i a n .c o m
1330 RODEO ROAD
JIE HE AND KATHERINE MANWAI
ARCADIA, CALIFORNIA 91006
NA
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
E
X
P
R
E
S
S
L
Y
R
E
S
E
R
V
E
S
I
T
S
C
O
M
M
O
N
L
A
W
C
O
P
Y
R
I
G
H
T
A
N
D
O
T
H
E
R
P
R
O
P
E
R
T
Y
R
I
G
H
T
S
I
N
T
H
E
S
E
P
L
A
N
S
.
T
H
E
S
E
P
L
A
N
S
A
R
E
N
O
T
T
O
B
E
R
E
P
R
O
D
U
C
E
D
,
C
H
A
N
G
E
D
O
R
C
O
P
I
E
D
I
N
A
N
Y
F
O
R
M
O
R
M
A
N
N
E
R
W
H
A
T
S
O
E
V
E
R
,
N
O
R
A
R
E
T
H
E
Y
T
O
B
E
A
S
S
I
G
N
E
D
T
O
A
T
H
I
R
D
P
A
R
T
Y
W
I
T
H
O
U
T
F
I
R
S
T
O
B
T
A
I
N
I
N
G
T
H
E
E
X
P
R
E
S
S
W
R
I
T
T
E
N
P
E
R
M
I
S
S
I
O
N
A
N
D
C
O
N
S
E
N
T
O
F
N
A
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
.
OWNER:
PROJECT:
RESIDENTIAL REMODEL
1330 RODEO ROAD
ARCADIA, CALIFORNIA 91006
SCALE: 1/4' = 1'-0"WEST ELEVATION 1
SCALE: 1/4' = 1'-0"NORTH ELEVATION 2
SCALE: 1/4' = 1'-0"EAST ELEVATION 3
SCALE: 1/4' = 1'-0"SOUTH ELEVATION 4
CLOSET
CLOSET
LINEN
BUILT-IN STORAGE
PANTRY
HE
A
D
E
R
@
7
3
"
UP
1
2
"
GUEST HOUSE
BEDROOM
CLOSET
BATH
KITCHEN
EL
E
C
.
P
A
N
E
L
LI
N
E
N
SH
E
L
V
E
S
CLOSET
48" REF.
CLOSET CLOSET
WA
S
H
E
R
DR
Y
E
R
W/H
LINEN
CLOSET
BUILT-IN STORAGEBUILT-IN STORAGE
SH
O
E
S
H
E
L
F
W/D
LAUNDRY
125
BEDROOM 4
121
BEDROOM 5
123
BATH 2
118
BEDROOM 2
117
MASTER BATH
116
MASTER BEDROOM
115
HALLWAY
114
FAMILY ROOM
106
KITCHEN
107
ATTRIUM
104
LIVING ROOM
102
SITTING AREA
103
BEDROOM 6
111
BATHROOM 5
112
OFFICE
108
MUDD ROOM
109
UP 12"
MUDD BATH
113
BUILT-IN STORAGE
LI
N
E
N
BATH 3
120
W/C
LI
N
E
N
LINEN
HALLWAY
126
POWDER RM
124
LINEN
86'-11"
4'
-
2
"
3'
-
9
"
15
'
-
2
12"
8'-1012"15'-112"13'-212"3'-1112"5'-11"14'-5"59'-5"
25
'
-
6
"
OUTDOOR
KITCHEN
127
35
'
12'-11"12'-212"8'-112"7'-112"8'-1112"9'-101
2"27'-81
2"
(E)F.P.
(E)F.P.
(E)F.P.
12'-4"
6'
-
5
12"
5'
-
1
0
12"
10
'
-
1
0
"
11
'
-
1
0
12"
6'
-
5
"
14
'
-
5
"
29
'
-
7
"
25
'
-
6
"
18'-212"
20
'
-
7
"
18'-112"
11
'
-
9
12"
7'
-
2
12"
7'
-
2
12"
41'-2"
103
102
107 102 106
105
103
8'-2"2'-1"
16'-2"73'-10"
14
'
-
6
12"
2'
-
1
"
7'
-
1
1
1 2"
7'
-
6
1 2"
15
'
-
2
"
15
'
-
6
"
15
'
-
2
"
A03
A04
A05 A06
A09
A04
A03
A10
27'-1112"
20
'
-
5
"
2
A4.2
1
A4.0
2
A4.0
1
A4.1
17'-10"
19
'
-
7
12"
15
'
-
2
12"
14'-10"
3'
-
1
1
"
9'
-
2
12"
11'-912"
25'
16
'
FOYER
101
GARAGE
128
A02
A01
POOL
BATH
129
20'-012"
COVERED
PATIO
130
OUTDOOR
LIVING AREA
131
9'-712"
A07
A07 A08
TRASH
YARD
131
104
108 A11
BATH 4
122
BEDROOM 3
119
16
'
-
3
"
11'-3"
17
'
-
1
"
11'-2"
17
'
-
1
"
19'-7"
15
'
-
1
1
"
107 102 107
102
101
A02
A02
A03
101
SCALE: 1/4' = 1'-0"FLOOR PLAN 1
N A T A L I E
K A Z A N J I A N
A R C H I T E C T
1 2 0 4 D O N J O S E D R I V E
G L E N D A L E , C A 9 1 2 0 7
T : 3 1 0 .7 4 8 .9 2 1 8
i n f o @ n a t a l i e k a z a n j i a n .c o m
n a t a l i e k a z a n j i a n .c o m
1330 RODEO ROAD
JIE HE AND KATHERINE MANWAI
ARCADIA, CALIFORNIA 91006
NA
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
E
X
P
R
E
S
S
L
Y
R
E
S
E
R
V
E
S
I
T
S
C
O
M
M
O
N
L
A
W
C
O
P
Y
R
I
G
H
T
A
N
D
O
T
H
E
R
P
R
O
P
E
R
T
Y
R
I
G
H
T
S
I
N
T
H
E
S
E
P
L
A
N
S
.
T
H
E
S
E
P
L
A
N
S
A
R
E
N
O
T
T
O
B
E
R
E
P
R
O
D
U
C
E
D
,
C
H
A
N
G
E
D
O
R
C
O
P
I
E
D
I
N
A
N
Y
F
O
R
M
O
R
M
A
N
N
E
R
W
H
A
T
S
O
E
V
E
R
,
N
O
R
A
R
E
T
H
E
Y
T
O
B
E
A
S
S
I
G
N
E
D
T
O
A
T
H
I
R
D
P
A
R
T
Y
W
I
T
H
O
U
T
F
I
R
S
T
O
B
T
A
I
N
I
N
G
T
H
E
E
X
P
R
E
S
S
W
R
I
T
T
E
N
P
E
R
M
I
S
S
I
O
N
A
N
D
C
O
N
S
E
N
T
O
F
N
A
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
.
OWNER:
PROJECT:
RESIDENTIAL REMODEL
1330 RODEO ROAD
ARCADIA, CALIFORNIA 91006
A-2.0
FLOOR PLAN
A#
#
(N) WINDOW, SEE WINDOW SCHEDULE
(N) DOOR, SEE DOOR SCHEDULE
(N) WALL
(N)NEW
CM
SD
CARBON MONOXIDE DETECTOR
SMOKE DETECTOR, NOTE: ALL SMOKE DETECTORS 10 YEARS OR
OLDER SHALL BE REPLACED.
EXHAUST FAN ENERGYSTAR HUMIDISTAT CONTROLLED FANS. DUCTED
OUT 3FT. AWAY FROM WINDOWS AND DOORS (MINIMUM VENTILATION
RATES OF 50 MIN CFM/UNIT FOR CONTINUOUS VENTILATION ARE
PROVIDED, THEY WILL BE VENTED THROUGH ROOF).
-50 CFM WITH HUMIDITY CONTROL AT BATHROOM EXHAUST FAN
-MINIMUM 100 CFM AT KITCHEN HOOD
LEGEND 2
(E) WALL
(E)EXISTING
ATRIUM
OPEN TO ABOVE
(N)FLAT ROOF
(N)SLOPE
6:12 DN
(N)SLOPE
6:12 DN
(N)SLOPE
2:12 DN
(N
)
SL
O
P
E
6:
1
2
D
N
(N
)
SL
O
P
E
6:
1
2
D
N
(N
)
SL
O
P
E
6:
1
2
D
N
(N
)
SL
O
P
E
6:
1
2
D
N
(N)SLOPE
6:12 DN
(N
)
SL
O
P
E
6:
1
2
D
N
(N) RIDGE
(N) RIDGE
(N) RIDGE
(N) RIDGE
(N) RIDGE
(N
)
R
I
D
G
E
LI
N
E
O
F
B
U
I
L
D
I
N
G
CO
L
U
M
N
S
RO
O
F
E
D
G
E
CO
L
U
M
N
S
CO
L
U
M
N
S
LI
N
E
O
F
B
U
I
L
D
I
N
G
(E)CHIMNEY
SL
O
P
E
DN
SL
O
P
E
DN
SL
O
P
E
DN
SL
O
P
E
DN
SL
O
P
E
DN
SL
O
P
E
DN
(E)CHIMNEY
45°
(N
)
SL
O
P
E
6:
1
2
D
N
(E)SLOPE
4:12 DN
(E)SLOPE
4:12 DN
(E
)
SL
O
P
E
LINE OF BUILDING
LINE OF BUILDING
(N)SLOPE
6:12 DN
(N
)
SL
O
P
E
6:
1
2
D
N
(E)SLOPE
4:12 DN
(E)SLOPE
(N)FLAT ROOF
BORAL
CEDARLITE 600 - AUTUMNWOOD
SOLAR REFLECTANCE .13, THERMAL
EMITTANCE .87, SRI 8
INSTALL PER MANUFACTURER
RECOMMENDATIONS
UL CLASS A FIRE RESISTANCE
UES-ER-412
BORAL
CEDARLITE 600 - AUTUMNWOOD
SOLAR REFLECTANCE .13, THERMAL
EMITTANCE .87, SRI 8
INSTALL PER MANUFACTURER
RECOMMENDATIONS
UL CLASS A FIRE RESISTANCE
UES-ER-412
BORAL
CEDARLITE 600 - AUTUMNWOOD
SOLAR REFLECTANCE .13, THERMAL
EMITTANCE .87, SRI 8
INSTALL PER MANUFACTURER
RECOMMENDATIONS
UL CLASS A FIRE RESISTANCE
UES-ER-412
BORAL
CEDARLITE 600 - AUTUMNWOOD
SOLAR REFLECTANCE .13, THERMAL
EMITTANCE .87, SRI 8
INSTALL PER MANUFACTURER
RECOMMENDATIONS
UL CLASS A FIRE RESISTANCE
UES-ER-412
(N)ROOF 7,639 SQ. FT.
(E)FLAT ROOF TO REMAIN - 1,281 SQ. FT.
4:12 DN
(E
)
CH
I
M
N
E
Y
4:
1
2
D
N
TOTAL: 8,920 SQ. FT.
(N
)
SL
O
P
E
6:
1
2
D
N
(N
)
SL
O
P
E
6:
1
2
D
N
(N
)
SL
O
P
E
6:
1
2
D
N
(N
)
SL
O
P
E
6:
1
2
D
N
(N
)
SL
O
P
E
6:
1
2
D
N
(N
)
SL
O
P
E
6:
1
2
D
N
PROPOSED
ROOF PLAN
A-2.1
N A T A L I E
K A Z A N J I A N
A R C H I T E C T
1 2 0 4 D O N J O S E D R I V E
G L E N D A L E , C A 9 1 2 0 7
T : 3 1 0 .7 4 8 .9 2 1 8
i n f o @ n a t a l i e k a z a n j i a n .c o m
n a t a l i e k a z a n j i a n .c o m
1330 RODEO ROAD
JIE HE AND KATHERINE MANWAI
ARCADIA, CALIFORNIA 91006
NA
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
E
X
P
R
E
S
S
L
Y
R
E
S
E
R
V
E
S
I
T
S
C
O
M
M
O
N
L
A
W
C
O
P
Y
R
I
G
H
T
A
N
D
O
T
H
E
R
P
R
O
P
E
R
T
Y
R
I
G
H
T
S
I
N
T
H
E
S
E
P
L
A
N
S
.
T
H
E
S
E
P
L
A
N
S
A
R
E
N
O
T
T
O
B
E
R
E
P
R
O
D
U
C
E
D
,
C
H
A
N
G
E
D
O
R
C
O
P
I
E
D
I
N
A
N
Y
F
O
R
M
O
R
M
A
N
N
E
R
W
H
A
T
S
O
E
V
E
R
,
N
O
R
A
R
E
T
H
E
Y
T
O
B
E
A
S
S
I
G
N
E
D
T
O
A
T
H
I
R
D
P
A
R
T
Y
W
I
T
H
O
U
T
F
I
R
S
T
O
B
T
A
I
N
I
N
G
T
H
E
E
X
P
R
E
S
S
W
R
I
T
T
E
N
P
E
R
M
I
S
S
I
O
N
A
N
D
C
O
N
S
E
N
T
O
F
N
A
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
.
OWNER:
PROJECT:
RESIDENTIAL REMODEL
1330 RODEO ROAD
ARCADIA, CALIFORNIA 91006
SCALE: 1/4' = 1'-0"PROPOSED ROOF PLAN 1
SLOPE
SLOPE
12:12 DN
SLOPE
SLOPE
SLOPE
SL
O
P
E
SLOPE
DN
SLOPE
SLOPE
FLAT ROOF
FLAT ROOF
(E
)
P
A
R
A
P
E
T
(E) PARAPET
(E) PARAPET
(E
)
P
A
R
A
P
E
T
(E) PARAPET
(E
)
P
A
R
A
P
E
T
(E) PARAPET(E) PARAPET
12:12 DN
12:12 DN
12:12 DN
12
:
1
2
D
N
4:12 DN 4:12 DN
4:12 DN
(E)CHIMNEY
(E)CHIMNEY
(E
)
CH
I
M
N
E
Y
(E)FLAT ROOF = 6,333 SQ. FT.
ATRIUM
OPEN TO ABOVE
SLOPE
4:12 DN
SL
O
P
E
12
:
1
2
D
N
(E
)
P
A
R
A
P
E
T
SL
O
P
E
12
:
1
2
D
N
SL
O
P
E
12
:
1
2
D
N
SL
O
P
E
12
:
1
2
D
N
SLOPE
DN
SL
O
P
E
DN
SL
O
P
E
DN
SL
O
P
E
12
:
1
2
D
N
SL
O
P
E
4:
1
2
D
N
SL
O
P
E
4:
1
2
D
N
SL
O
P
E
4:
1
2
D
N
SL
O
P
E
4:
1
2
D
N
EXISTING
ROOF PLAN
-
N A T A L I E
K A Z A N J I A N
A R C H I T E C T
1 2 0 4 D O N J O S E D R I V E
G L E N D A L E , C A 9 1 2 0 7
T : 3 1 0 .7 4 8 .9 2 1 8
i n f o @ n a t a l i e k a z a n j i a n .c o m
n a t a l i e k a z a n j i a n .c o m
1330 RODEO ROAD
JIE HE AND KATHERINE MANWAI
ARCADIA, CALIFORNIA 91006
NA
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
E
X
P
R
E
S
S
L
Y
R
E
S
E
R
V
E
S
I
T
S
C
O
M
M
O
N
L
A
W
C
O
P
Y
R
I
G
H
T
A
N
D
O
T
H
E
R
P
R
O
P
E
R
T
Y
R
I
G
H
T
S
I
N
T
H
E
S
E
P
L
A
N
S
.
T
H
E
S
E
P
L
A
N
S
A
R
E
N
O
T
T
O
B
E
R
E
P
R
O
D
U
C
E
D
,
C
H
A
N
G
E
D
O
R
C
O
P
I
E
D
I
N
A
N
Y
F
O
R
M
O
R
M
A
N
N
E
R
W
H
A
T
S
O
E
V
E
R
,
N
O
R
A
R
E
T
H
E
Y
T
O
B
E
A
S
S
I
G
N
E
D
T
O
A
T
H
I
R
D
P
A
R
T
Y
W
I
T
H
O
U
T
F
I
R
S
T
O
B
T
A
I
N
I
N
G
T
H
E
E
X
P
R
E
S
S
W
R
I
T
T
E
N
P
E
R
M
I
S
S
I
O
N
A
N
D
C
O
N
S
E
N
T
O
F
N
A
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
.
OWNER:
PROJECT:
RESIDENTIAL REMODEL
1330 RODEO ROAD
ARCADIA, CALIFORNIA 91006
SCALE: 1/4' = 1'-0"EXISTING ROOF PLAN 1
FINISH FLOOR
0'-0"
CEILING PLATE
9'-0"
TOP OF RIDGE
16'-11"
FINISH FLOOR
1'-0"
CEILING PLATE
11'-0"
TOP OF RIDGE
18'-3"
10
'
8'
7'
-
3
"
8'
-
1
0
12"
12
6
12
6
12
6
FINISH FLOOR
1'-0"
CEILING PLATE
11'-0"
TOP OF RIDGE
18'-4"
CEILING PLATE
10'-0"
10
'
7'
-
3
"
FINISH FLOOR
1'-0"
TOP OF RIDGE
18'-4"
4
0
.
0
0
°
12
6
12
6
BUILDING
ELEVATIONS
A-4.0
N A T A L I E
K A Z A N J I A N
A R C H I T E C T
1 2 0 4 D O N J O S E D R I V E
G L E N D A L E , C A 9 1 2 0 7
T : 3 1 0 .7 4 8 .9 2 1 8
i n f o @ n a t a l i e k a z a n j i a n .c o m
n a t a l i e k a z a n j i a n .c o m
1330 RODEO ROAD
JIE HE AND KATHERINE MANWAI
ARCADIA, CALIFORNIA 91006
NA
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
E
X
P
R
E
S
S
L
Y
R
E
S
E
R
V
E
S
I
T
S
C
O
M
M
O
N
L
A
W
C
O
P
Y
R
I
G
H
T
A
N
D
O
T
H
E
R
P
R
O
P
E
R
T
Y
R
I
G
H
T
S
I
N
T
H
E
S
E
P
L
A
N
S
.
T
H
E
S
E
P
L
A
N
S
A
R
E
N
O
T
T
O
B
E
R
E
P
R
O
D
U
C
E
D
,
C
H
A
N
G
E
D
O
R
C
O
P
I
E
D
I
N
A
N
Y
F
O
R
M
O
R
M
A
N
N
E
R
W
H
A
T
S
O
E
V
E
R
,
N
O
R
A
R
E
T
H
E
Y
T
O
B
E
A
S
S
I
G
N
E
D
T
O
A
T
H
I
R
D
P
A
R
T
Y
W
I
T
H
O
U
T
F
I
R
S
T
O
B
T
A
I
N
I
N
G
T
H
E
E
X
P
R
E
S
S
W
R
I
T
T
E
N
P
E
R
M
I
S
S
I
O
N
A
N
D
C
O
N
S
E
N
T
O
F
N
A
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
.
OWNER:
PROJECT:
RESIDENTIAL REMODEL
1330 RODEO ROAD
ARCADIA, CALIFORNIA 91006
SCALE: 1/4' = 1'-0"NORTH ELEVATION 2
1
2
3
4
5
6
7
ELEVATION NOTES
STUCCO- SAND FINISH COLOR: EARTHTONED (SANTA FE)
SIDING: JAMES HARDIE TEXTURED - COBBLE STONE
GUTTER AND DOWNSPOUT WITH PAINT FINISH
6X6 WOOD POST COLOR: OFF-WHITE
LOUVERED WOOD SHUTTERS AT 18" WIDE W/ CENTER RAIL
2 x 6 FASCIA: COLOR OFF WHITE
ASPHALT SINGLES - CERTAINTEED LANDMARK TL SOLARIS MOIRE BLACK
BRICK VENEER: TRUE SOLID AGED BRICK WAINSCOT - WHITE8
2 2 277
8 88
SCALE: 1/4' = 1'-0"WEST ELEVATION 1
(E) STUCCO
FINISH FLOOR
1'-0"
CEILING PLATE
10'-0"
TOP OF RIDGE
18'-3"
9'
8'
-
3
"
12
6
FINISH FLOOR
1'-0"
CEILING PLATE
11'-0"
CEILING PLATE
10'-0"
TOP OF RIDGE
18'-3"
TOP OF RIDGE
18'-0"
12
6
BUILDING
ELEVATIONS
A-4.1
N A T A L I E
K A Z A N J I A N
A R C H I T E C T
1 2 0 4 D O N J O S E D R I V E
G L E N D A L E , C A 9 1 2 0 7
T : 3 1 0 .7 4 8 .9 2 1 8
i n f o @ n a t a l i e k a z a n j i a n .c o m
n a t a l i e k a z a n j i a n .c o m
1330 RODEO ROAD
JIE HE AND KATHERINE MANWAI
ARCADIA, CALIFORNIA 91006
NA
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
E
X
P
R
E
S
S
L
Y
R
E
S
E
R
V
E
S
I
T
S
C
O
M
M
O
N
L
A
W
C
O
P
Y
R
I
G
H
T
A
N
D
O
T
H
E
R
P
R
O
P
E
R
T
Y
R
I
G
H
T
S
I
N
T
H
E
S
E
P
L
A
N
S
.
T
H
E
S
E
P
L
A
N
S
A
R
E
N
O
T
T
O
B
E
R
E
P
R
O
D
U
C
E
D
,
C
H
A
N
G
E
D
O
R
C
O
P
I
E
D
I
N
A
N
Y
F
O
R
M
O
R
M
A
N
N
E
R
W
H
A
T
S
O
E
V
E
R
,
N
O
R
A
R
E
T
H
E
Y
T
O
B
E
A
S
S
I
G
N
E
D
T
O
A
T
H
I
R
D
P
A
R
T
Y
W
I
T
H
O
U
T
F
I
R
S
T
O
B
T
A
I
N
I
N
G
T
H
E
E
X
P
R
E
S
S
W
R
I
T
T
E
N
P
E
R
M
I
S
S
I
O
N
A
N
D
C
O
N
S
E
N
T
O
F
N
A
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
.
OWNER:
PROJECT:
RESIDENTIAL REMODEL
1330 RODEO ROAD
ARCADIA, CALIFORNIA 91006
7
8 8
6 6
5
21
SCALE: 1/4' = 1'-0"SOUTH ELEVATION 2
SCALE: 1/4' = 1'-0"EAST ELEVATION 1
ELEVATION NOTES
STUCCO- SAND FINISH COLOR: EARTHTONED (SANTA FE)
SIDING: JAMES HARDIE TEXTURED - COBBLE STONE
GUTTER AND DOWNSPOUT WITH PAINT FINISH
6X6 WOOD POST COLOR: OFF-WHITE
LOUVERED WOOD SHUTTERS AT 18" WIDE W/ CENTER RAIL
2 x 6 FASCIA: COLOR OFF WHITE
ASPHALT SINGLES - CERTAINTEED LANDMARK TL SOLARIS MOIRE BLACK
BRICK VENEER: TRUE SOLID AGED BRICK WAINSCOT - WHITE
1
2
3
4
5
6
7
8
LIVING ROOM
102 FOYER
101
BEDROOM 5
123
BEDROOM 4
121
SITTING AREA
103
10
'
12
6
10
'
8'
KITCHEN
107
DINING
ROOM
105
ATTRIUM
104
LIVING ROOM
102
OUTDOOR
KITCHEN
127
BUILDING
SECTIONS
SCALE: 1/4" = 1'-0"SECTION 2 2
A-4.2
N A T A L I E
K A Z A N J I A N
A R C H I T E C T
1 2 0 4 D O N J O S E D R I V E
G L E N D A L E , C A 9 1 2 0 7
T : 3 1 0 .7 4 8 .9 2 1 8
i n f o @ n a t a l i e k a z a n j i a n .c o m
n a t a l i e k a z a n j i a n .c o m
1330 RODEO ROAD
JIE HE AND KATHERINE MANWAI
ARCADIA, CALIFORNIA 91006
NA
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
E
X
P
R
E
S
S
L
Y
R
E
S
E
R
V
E
S
I
T
S
C
O
M
M
O
N
L
A
W
C
O
P
Y
R
I
G
H
T
A
N
D
O
T
H
E
R
P
R
O
P
E
R
T
Y
R
I
G
H
T
S
I
N
T
H
E
S
E
P
L
A
N
S
.
T
H
E
S
E
P
L
A
N
S
A
R
E
N
O
T
T
O
B
E
R
E
P
R
O
D
U
C
E
D
,
C
H
A
N
G
E
D
O
R
C
O
P
I
E
D
I
N
A
N
Y
F
O
R
M
O
R
M
A
N
N
E
R
W
H
A
T
S
O
E
V
E
R
,
N
O
R
A
R
E
T
H
E
Y
T
O
B
E
A
S
S
I
G
N
E
D
T
O
A
T
H
I
R
D
P
A
R
T
Y
W
I
T
H
O
U
T
F
I
R
S
T
O
B
T
A
I
N
I
N
G
T
H
E
E
X
P
R
E
S
S
W
R
I
T
T
E
N
P
E
R
M
I
S
S
I
O
N
A
N
D
C
O
N
S
E
N
T
O
F
N
A
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
.
OWNER:
PROJECT:
RESIDENTIAL REMODEL
1330 RODEO ROAD
ARCADIA, CALIFORNIA 91006
SECTION 1 1
9'
8'-5"
2'-4"3'-6"2'-4"
5'-0"
2'-6"
8'
2'-6"
5'-0"
2'-6"2'-6"1'-6"1'-6"
8'-4"
3'
8'
17'
7'
-
8
"
7'
-
8
"
3'
7'
-
8
"
7'
-
8
"
2'-8"
3'
7'
-
8
"
5'-0"
2'-6"2'-6"1'-6"1'-6"
8'-4"
8'
8'
E F G H
I J
10'
K
6'
6'
-
8
"
A-5.0
N A T A L I E
K A Z A N J I A N
A R C H I T E C T
1 2 0 4 D O N J O S E D R I V E
G L E N D A L E , C A 9 1 2 0 7
T : 3 1 0 .7 4 8 .9 2 1 8
i n f o @ n a t a l i e k a z a n j i a n .c o m
n a t a l i e k a z a n j i a n .c o m
1330 RODEO ROAD
JIE HE AND KATHERINE MANWAI
ARCADIA, CALIFORNIA 91006
NA
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
E
X
P
R
E
S
S
L
Y
R
E
S
E
R
V
E
S
I
T
S
C
O
M
M
O
N
L
A
W
C
O
P
Y
R
I
G
H
T
A
N
D
O
T
H
E
R
P
R
O
P
E
R
T
Y
R
I
G
H
T
S
I
N
T
H
E
S
E
P
L
A
N
S
.
T
H
E
S
E
P
L
A
N
S
A
R
E
N
O
T
T
O
B
E
R
E
P
R
O
D
U
C
E
D
,
C
H
A
N
G
E
D
O
R
C
O
P
I
E
D
I
N
A
N
Y
F
O
R
M
O
R
M
A
N
N
E
R
W
H
A
T
S
O
E
V
E
R
,
N
O
R
A
R
E
T
H
E
Y
T
O
B
E
A
S
S
I
G
N
E
D
T
O
A
T
H
I
R
D
P
A
R
T
Y
W
I
T
H
O
U
T
F
I
R
S
T
O
B
T
A
I
N
I
N
G
T
H
E
E
X
P
R
E
S
S
W
R
I
T
T
E
N
P
E
R
M
I
S
S
I
O
N
A
N
D
C
O
N
S
E
N
T
O
F
N
A
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
.
OWNER:
PROJECT:
RESIDENTIAL REMODEL
1330 RODEO ROAD
ARCADIA, CALIFORNIA 91006
NO.LOCATION WIDTH HEIGHT MATERIAL SHGC REMARKSTYPEGLAZING
A04
A03
A02
A01
F
C
HALLWAY (RM 110)D
FOYER (RM 101)A
8'-0"LOW E / DUAL GLAZE
SOLID WOOD9'-0"8'-5"DESIGN T.B.D.
B LIVING ROOM (RM 102), SITTING
ROOM (RM 103), OFFICE (RM 108)5'-0"8'-0"LOW E / DUAL GLAZE SWING DOUBLE DOORS
U-FACTOR
LOW E / SINGLE GLAZE TEMP.
3'-0"
ALUMI-CLAD
ALUMI-CLAD
8'-0"5'-0"ALUMI-CLAD LOW E / DUAL GLAZE
E 7'-8"17'-0"WOOD MOTORIZED OPENER SECTION DOOR - SEE
ELEVATIONSA05
G 7'-8"3'-0"
0.30 0.22
MANUFACTURER/PRODUCT
NAME
JELD-WEN / SITELINE EX
JELD-WEN / SITELINE EX
JELD-WEN / SITELINE EX
JELD-WEN / SITELINE EX
TBD
COLOR
BONE WHITE
BONE WHITE
BONE WHITE
BONE WHITE
BONE WHITE
SCHEDULE NOTES:
1. COMPLY WITH ALL APPLICABLE PROVISIONS OF THE 2010
CBC AS MODIFIED BY THE CITY OF LOS ANGELES MUNICIPAL
CODE.
2. GLAZING IN THE FOLLOWING HAZARDOUS LOCATIONS SHALL BE
SAFETY GLAZING (PERMANENT TEMPERED) CONFORMING TO THE
HUMAN IMPACT LOADS OF SECTION R308.3 (SEE EXCEPTIONS)
(R308.4):
(GLAZING IN A HAZARDOUS LOCATION SHALL BE TEMPERED.)
NOTE:
1. SEE ELEVATIONS FOR LITE CUT-UPS & SWINGS
2. PAINTED EXTERIOR / INTERIOR - COLOR AND FINISH AS PER OWNER
3. NEW WINDOWS -SUBMIT SAMPLE FOR APPROVAL
REVIEW ALL WINDOW & DOOR SIZES, LITE CUT-UPS, OPERATION,
HARDWARE AND SCREENS W/ OWNERS AND ARCHITECT PRIOR TO PLACING
WINDOW ORDER.
4. PROVIDE DOOR JAMBS, HINGES, HARDWARE WEATHER STRIPPING
AS REQUIRED
A. FIXED AND OPERABLE PANELS OF SWINGING,
SLIDING AND BIFOLD DOOR ASSEMBLIES.
B. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE
PANEL ADJACENT TO A DOOR WHERE THE NEAREST
VERTICAL EDGE IS WITHIN A 24-INCH ARC OF THE
DOOR IN A CLOSED POSITION AND WHOSE BOTTOM
EDGE IS LESS THAN 60 INCHES ABOVE THE FLOOR OR
WALKING SURFACE.
C. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE
PANEL THAT MEETS ALL OF THE FOLLOWING
CONDITIONS:
I. EXPOSED AREA OF AN INDIVIDUAL PANE
GREATER THAN 9 SQUARE FEET.
II. BOTTOM EDGE LESS THAN 18 INCHES ABOVE
THE FLOOR.
III. TOP EDGE GREATER THAN 36 INCHES ABOVE
THE FLOOR.
IV. ONE OR MORE WALKING SURFACES WITHIN 36
INCHES HORIZONTALLY OF THE GLAZING.
D. GLAZING IN RAILINGS.
E. GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT
TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS,
BATHTUBS AND SHOWERS WHERE THE BOTTOM
EDGE OF THE GLAZING IS LESS THAN 60 INCHES
MEASURED VERTICALLY ABOVE ANY STANDING OR
WALKING SURFACE.
F. GLAZING IN WALLS AND FENCES ADJACENT TO
INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS
AND SPAS WHERE THE BOTTOM EDGE OF THE
GLAZING IS LESS THAN 60 INCHES ABOVE A
WALKING SURFACE AND WITHIN 60 INCHES,
MEASURED HORIZONTALLY AND IN A STRAIGHT LINE,
OF THE WATER' S EDGE.
G. GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND
RAMPS WITHIN 36 INCHES HORIZONTALLY OF A
WALKING SURFACE WHEN THE SURFACE OF THE
glazing is less than 60 inches above the
plane of the adjacent walking surface.
3. PROVIDE A MINIMUM OF 1 MEANS OF EMERGENCY EGRESS
WINDOW OR DOOR MUST
PROVIDE A MINIMUM OF 5.7 SQ. FT. OF OPENABLE AREA;
MINIMUM CLEAR WIDTH OF 20"; MINIMUM CLEAR HEIGHT OF
24"; AND HAVE A FINISHED SILL HEIGHT OF NOT MORE THAN
44" ABOVE THE FINISHED FLOOR.
4. DOORS AND ENCLOSURES FOR HOT TUBS, BATH TUBS,
SHOWERS (ALSO GLAZING IN WALLS ENCLOSING THESE
COMPARTMENTS WITHIN 5'-0" OF STANDING SURFACE,) INGRESS
AND EGRESS DOORS, PANELS IN SLIDING OR SWINGING DOORS
SHALL BE TEMPERED.
5. PAIRS OF DOORS WITH LEAVES NARROWER THAN 2'-8" SHALL
HAVE HARDWARE TO MAKE BOTH LEAVES OPERABLE.
6. SEE ELEVATIONS & SECTIONS FOR ADDITIONAL INFORMATION.
7. GLAZING IN THE FOLLOWING LOCATIONS SHALL BE SAFETY
GLAZING CONFORMING TO THE HUMAN IMPACT LOADS OF
SECTION R308.3(SEE EXEMPTIONS) (R308.4):
A. FIXED AND OPERABLE PANELS OF SWINGING, SLIDING
AND BI-FOLD DOORS.
B. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL
ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL
EDGE IS WITHIN A 24 INCH ARC OF THE DOOR IN A
CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS
THAN 60 INCHES ABOVE THE FLOOR OR WALKING SURFACE.
C. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL
THAT MEETS ALL OF THE FOLLOWING CONDITIONS:
1) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER
THAN 9 SQUARE FEET.
2) BOTTOM EDGE LESS THAN 18 INCHES ABOVE FLOOR
3) TOP EDGE GREATER THAN 36 INCHES ABOVE FLOOR
4) ONE OR MORE WALKING SURFACES WITHIN 36
INCHES HORIZONTALLY OF THE GLAZING.
D. GLAZING IN RAILINGS
SITTING RM (RM 103), FAMILY ROOM
(RM 106), BEDROOM 4 (RM 108)
H
I
J
A06
A07
A08
A09
A10 MASTER BEDROOM (RM 115)5'-0"8'-0"LOW E / DUAL GLAZE SWING DOUBLE DOORS - WITH FIXED
SIDELITESALUMI-CLAD JELD-WEN / SITELINE EX BONE WHITE
SWING DOUBLE DOORS - WITH FIXED
SIDELITES
SWING DOOR
GARAGE (RM 128)
GARAGE (RM 128)7'-8"10'-0"BONE WHITETBDWOOD
LOW E / DUAL GLAZEALUMI-CLAD JELD-WEN / SITELINE EX BONE WHITE SWING DOORSGUEST HOUSE
POOL BATH (RM 129)7'-8"2'-8"WOOD BONE WHITE SWING DOORS
GARAGE (RM 128)7'-8"3'-0"WOOD BONE WHITE SWING 1-HOUR FIRE RATED
DOORS
KA11 6'-0"6'-8"LOW E / DUAL GLAZE SLIDING DOORSALUMI-CLAD JELD-WEN / SITELINE EX BONE WHITEGUEST HOUSE
0.30 0.22
0.30 0.22
0.30 0.22
0.30 0.22
0.30 0.22
0.30 0.22
MOTORIZED OPENER SECTION DOOR - SEE
ELEVATIONS
EXTERIOR DOOR SCHEDULE
1 2 3 4 5
6 7 8
5'
5'
-
4
"
2'
-
8
"
2'-6"
4'
-
4
"
3'
-
8
"
2'-4"
4'
-
4
"
4'
-
8
"
3'
4'
3'
-
8
"
12'-2"
6'
-
0
"
3'
2'-5"2'-5"
2'-5"2'-5"2'-5"2'-5"2'-5"
5'
-
8
"
2'
-
4
"
3'-6"
4'
-
6
"
3'
-
6
"
6'-0"
3'-0"3'
4'
-
8
"
5'-8"
2'-10"2'-10"
2'
-
1
0
"
WINDOW
SCHEDULE
A-5.1
N A T A L I E
K A Z A N J I A N
A R C H I T E C T
1 2 0 4 D O N J O S E D R I V E
G L E N D A L E , C A 9 1 2 0 7
T : 3 1 0 .7 4 8 .9 2 1 8
i n f o @ n a t a l i e k a z a n j i a n .c o m
n a t a l i e k a z a n j i a n .c o m
1330 RODEO ROAD
JIE HE AND KATHERINE MANWAI
ARCADIA, CALIFORNIA 91006
NA
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
E
X
P
R
E
S
S
L
Y
R
E
S
E
R
V
E
S
I
T
S
C
O
M
M
O
N
L
A
W
C
O
P
Y
R
I
G
H
T
A
N
D
O
T
H
E
R
P
R
O
P
E
R
T
Y
R
I
G
H
T
S
I
N
T
H
E
S
E
P
L
A
N
S
.
T
H
E
S
E
P
L
A
N
S
A
R
E
N
O
T
T
O
B
E
R
E
P
R
O
D
U
C
E
D
,
C
H
A
N
G
E
D
O
R
C
O
P
I
E
D
I
N
A
N
Y
F
O
R
M
O
R
M
A
N
N
E
R
W
H
A
T
S
O
E
V
E
R
,
N
O
R
A
R
E
T
H
E
Y
T
O
B
E
A
S
S
I
G
N
E
D
T
O
A
T
H
I
R
D
P
A
R
T
Y
W
I
T
H
O
U
T
F
I
R
S
T
O
B
T
A
I
N
I
N
G
T
H
E
E
X
P
R
E
S
S
W
R
I
T
T
E
N
P
E
R
M
I
S
S
I
O
N
A
N
D
C
O
N
S
E
N
T
O
F
N
A
T
A
L
I
E
K
A
Z
A
N
J
I
A
N
A
R
C
H
I
T
E
C
T
.
OWNER:
PROJECT:
RESIDENTIAL REMODEL
1330 RODEO ROAD
ARCADIA, CALIFORNIA 91006
NO.LOCATION WIDTH HEIGHT MATERIAL SHGC REMARKSTYPEGLAZING
105
103
102
101
5
4
3
BEDROOM 5 (RM 123)1
3'-0"4'-0"
6'-0"12'-2"
LOW E / DUAL GLAZE
ALUMI-CLAD
GUEST HOUSE
5'-4"5'-0"
LOW E / DUAL GLAZE
LOW E / DUAL GLAZE
2 BATH 4 (RM122), BEDROOM 4 CLOSET,
BATH 3 (RM120), BATH 2 (RM118)2'-3"4'-4"LOW E / DUAL GLAZE
U-FACTOR
LOW E / DUAL GLAZE
2'-4"
108
107
106
8
7
6
6'-0"
5'-8"
4'-6"
4'-8"5'-8"
LOW E / DUAL GLAZE
BEDROOM 4 (RM121), BEDROOM
3 (RM119), BEDROOM 2 (RM117)
GUEST HOUSE LOW E / DUAL GLAZE
LOW E / DUAL GLAZE
3'-6"
ALUMI-CLAD
ALUMI-CLAD
ALUMI-CLAD
ALUMI-CLAD
ALUMI-CLAD
ALUMI-CLAD
ALUMI-CLAD
BATHROOM 5 (RM112)4'-4"
KITCHEN (RM 107)
MASTER BATHROOM (RM 116)DBL HUNG - W/ SIMULATED DIVIDED LITES
@ 7 8 MUNTINS - TEMPERED GLASS
0.30 0.22
MANUFACTURER/PRODUCT NAME
JELD-WEN / SITELINE EX
JELD-WEN / SITELINE EX
JELD-WEN / SITELINE EX
JELD-WEN / SITELINE EX
JELD-WEN / SITELINE EX
JELD-WEN / SITELINE EX
JELD-WEN / SITELINE EX
JELD-WEN / SITELINE EX
BONE WHITE
COLOR
BONE WHITE
BONE WHITE
BONE WHITE
BONE WHITE
BONE WHITE
BONE WHITE
BONE WHITE
104
SCHEDULE NOTES:
1. COMPLY WITH ALL APPLICABLE PROVISIONS OF THE 2010
CBC AS MODIFIED BY THE CITY OF LOS ANGELES MUNICIPAL
CODE.
2. GLAZING IN THE FOLLOWING HAZARDOUS LOCATIONS SHALL BE
SAFETY GLAZING (PERMANENT TEMPERED) CONFORMING TO THE
HUMAN IMPACT LOADS OF SECTION R308.3 (SEE EXCEPTIONS)
(R308.4):
(GLAZING IN A HAZARDOUS LOCATION SHALL BE TEMPERED.)
NOTE:
1. SEE ELEVATIONS FOR LITE CUT-UPS & SWINGS
2. PAINTED EXTERIOR / INTERIOR - COLOR AND FINISH AS PER OWNER
3. NEW WINDOWS -SUBMIT SAMPLE FOR APPROVAL
REVIEW ALL WINDOW & DOOR SIZES, LITE CUT-UPS, OPERATION,
HARDWARE AND SCREENS W/ OWNERS AND ARCHITECT PRIOR TO PLACING
WINDOW ORDER.
4. PROVIDE DOOR JAMBS, HINGES, HARDWARE WEATHER STRIPPING
AS REQUIRED
A. FIXED AND OPERABLE PANELS OF SWINGING,
SLIDING AND BIFOLD DOOR ASSEMBLIES.
B. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE
PANEL ADJACENT TO A DOOR WHERE THE NEAREST
VERTICAL EDGE IS WITHIN A 24-INCH ARC OF THE
DOOR IN A CLOSED POSITION AND WHOSE BOTTOM
EDGE IS LESS THAN 60 INCHES ABOVE THE FLOOR OR
WALKING SURFACE.
C. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE
PANEL THAT MEETS ALL OF THE FOLLOWING
CONDITIONS:
I. EXPOSED AREA OF AN INDIVIDUAL PANE
GREATER THAN 9 SQUARE FEET.
II. BOTTOM EDGE LESS THAN 18 INCHES ABOVE
THE FLOOR.
III. TOP EDGE GREATER THAN 36 INCHES ABOVE
THE FLOOR.
IV. ONE OR MORE WALKING SURFACES WITHIN 36
INCHES HORIZONTALLY OF THE GLAZING.
D. GLAZING IN RAILINGS.
E. GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT
TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS,
BATHTUBS AND SHOWERS WHERE THE BOTTOM
EDGE OF THE GLAZING IS LESS THAN 60 INCHES
MEASURED VERTICALLY ABOVE ANY STANDING OR
WALKING SURFACE.
F. GLAZING IN WALLS AND FENCES ADJACENT TO
INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS
AND SPAS WHERE THE BOTTOM EDGE OF THE
GLAZING IS LESS THAN 60 INCHES ABOVE A
WALKING SURFACE AND WITHIN 60 INCHES,
MEASURED HORIZONTALLY AND IN A STRAIGHT LINE,
OF THE WATER' S EDGE.
G. GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND
RAMPS WITHIN 36 INCHES HORIZONTALLY OF A
WALKING SURFACE WHEN THE SURFACE OF THE
glazing is less than 60 inches above the
plane of the adjacent walking surface.
3. PROVIDE A MINIMUM OF 1 MEANS OF EMERGENCY EGRESS
WINDOW OR DOOR MUST
PROVIDE A MINIMUM OF 5.7 SQ. FT. OF OPENABLE AREA;
MINIMUM CLEAR WIDTH OF 20"; MINIMUM CLEAR HEIGHT OF
24"; AND HAVE A FINISHED SILL HEIGHT OF NOT MORE THAN
44" ABOVE THE FINISHED FLOOR.
4. DOORS AND ENCLOSURES FOR HOT TUBS, BATH TUBS,
SHOWERS (ALSO GLAZING IN WALLS ENCLOSING THESE
COMPARTMENTS WITHIN 5'-0" OF STANDING SURFACE,) INGRESS
AND EGRESS DOORS, PANELS IN SLIDING OR SWINGING DOORS
SHALL BE TEMPERED.
5. PAIRS OF DOORS WITH LEAVES NARROWER THAN 2'-8" SHALL
HAVE HARDWARE TO MAKE BOTH LEAVES OPERABLE.
6. SEE ELEVATIONS & SECTIONS FOR ADDITIONAL INFORMATION.
7. GLAZING IN THE FOLLOWING LOCATIONS SHALL BE SAFETY
GLAZING CONFORMING TO THE HUMAN IMPACT LOADS OF
SECTION R308.3(SEE EXEMPTIONS) (R308.4):
A. FIXED AND OPERABLE PANELS OF SWINGING, SLIDING
AND BI-FOLD DOORS.
B. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL
ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL
EDGE IS WITHIN A 24 INCH ARC OF THE DOOR IN A
CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS
C. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL
THAT MEETS ALL OF THE FOLLOWING CONDITIONS:
1) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER
THAN 9 SQUARE FEET.
2) BOTTOM EDGE LESS THAN 18 INCHES ABOVE FLOOR
3) TOP EDGE GREATER THAN 36 INCHES ABOVE FLOOR
4) ONE OR MORE WALKING SURFACES WITHIN 36
INCHES HORIZONTALLY OF THE GLAZING.
D. GLAZING IN RAILINGS
CASEMENT - W/ SIMULATED DIVIDED LITES
@ 7 8 MUNTINS- MEETS EGRESS
DBL HUNG - W/ SIMULATED DIVIDED LITES
@ 7 8 MUNTINS
CASEMENT - W/ SIMULATED DIVIDED LITES
@ 7 8 MUNTINS
CASEMENT - W/ SIMULATED DIVIDED LITES
@ 7 8 MUNTINS
FOLDING WINDOWS - W/ SIMULATED
DIVIDED LITES @ 7 8 MUNTINS
SLIDING - W/ SIMULATED DIVIDED LITES @
7 8 MUNTINS - MEETS EGRESS
CASEMENT - W/ SIMULATED DIVIDED LITES
@ 7 8 MUNTINS - MEETS EGRESS
WINDOW SCHEDULE
0.30 0.22
0.30 0.22
0.30 0.22
0.30 0.22
0.30 0.22
0.30 0.22
0.30 0.22