Loading...
HomeMy WebLinkAboutPlansSAN VICENTE RD WM 100' PROPERTY LINE EXISTING DRIVEWAY EXISTING ONE-STORY RESIDENTIAL 20 7 . 7 4 ' P R O P E R T Y L I N E 21 1 . 8 4 ' P R O P E R T Y L I N E 100.21' PROPERTY LINE N ELEC ELEC EL E C PROPOSED ONE-STORY ADU FR O N T S E T B A C K 48 ' - 8 " 52 ' - 3 " 21 ' - 7 " 33 ' - 0 " RE A R S E T B A C K 52 ' - 3 " 20 7 ' - 9 " 18' - 0" SETBACK 10' - 6" 5' - 4 " 22 ' - 2 " 75 ' - 4 " 52 ' - 1 " 56 ' - 1 1 " 100' - 0" 12' - 9" EXISTING TWO-CAR GARAGE (E) SHED ELEC 3' - 0" STEP 22 ' - 2 " NEW WORK SHOP 13' - 0" REFERENCE N0. REFERENCE N0. ELEVATION NO. ELEVATION NO. SHEET NO. DETAIL NO. SHEET NO. SHEET NO. DETAIL NO. ROOM NO. ROOM NO. SECTION NO. SHEET NO. SECTION NO. SHEET NO. SHEET NO. SHADED PORTION IS SIDE CONSIDERED DOOR SYMBOL WINDOW SYMBOL BUILDING GRID AREA DETAIL INT. ELEVATION EXT. ELEVATION 12.1 24A6.1 1 A3.1 2 A5.1 4 REFERENCE A1.1 4 DETAIL 1 LINES 1.A A N A3.4 3 2 A1.2 SECTION (CLOUD AROUND REV. OPTIONAL) REVISION NO. MATCH LINE WORK POINT CONTROL POINT OR DATUM POINT A2.1 3 REVISION CLOUD NORTH ARROW FINISH CEILING HEIGHT WALL SECTION N x'-x" SHEET NO.10 16 14 15 20 19 18 812 11 10 7 6 1317 95 4 3 2 1 24 22 23 21 ALL DRAWINGS AND DETAILS ARE IDENTIFIED BY THE GRID NUMBER IN THE LOWER RIGHT HAND CORNER. ALL NUMBER LOCATIONS CONFORM TO THIS GRID SYSTEM. PROPERTY LINE BUILDING LINE LEGEND: WATER FLOW DIRECTION LANDSCAPE CONCRETE DATE: REVISED: M- S I T U D E S I G N L L C PR O J E C T N A M E : APPROVAL STAMP: PROJ. NO: CO N S U L T A N T : SHEET TITLE: SHEET NO: 2024 M-SITU DESIGN LLC 24.01.15 T. 6 2 6 . 3 1 0 . 2 7 2 8 E. m s i t u . s t u d i o @ g m a i l . c o m A. 4 7 8 6 P E C K R O A D , # A , E L M O N T E , C A 9 1 7 3 2 MA N D Y S I T U T.1 SITE PALN, DRAWING INDEX & GENERAL NOTES 2023-30 87 0 S A N V I C C E N T E R D . AR C A D I A , C A 9 1 0 0 7 Sheet Number Sheet Name GENERAL T.1 SITE PALN, DRAWING INDEX & GENERAL NOTES T.2 GENERAL NOTES T.3 CALGREEN CHECKLIST T.4 CALGREEN CHECKLIST T.5 CALGREEN ARCHITECTURAL A2.1 DEMO & PROPOSED FLOOR PLANS A2.2 ELECTRICAL PLANS & REFLECTED CEILING PLANS A2.3 ROOF PLAN, DOOR & WINDOW SCHEDULES A2.4 ADU_BUILDING ELEVATIONS & SECTIONS A2.5 WORKSHOP _ BUILDING ELEVATIONS & SECTIONS STRUCTRAL S101 GENERAL NOTES S201 FOUNDATION PLAN S301 ROOF FRAMING PLAN S401 FOUNDATION DETAILS S501 FRAMING DETAILS S502 FRAMING DETAILS TITLE 24 T-24-1 TITLE 24 T-24-2 TITLE 24 T-24-3 TITLE 24 ARCHITECTURE DESIGNER: M-SITU DESIGN LLC. 4786 Peck Road, #A, El Monte, CA 91732 T/626.310.2728 CONTACT: MANDY SITU OWNER: T/626.825.8189 CONTACT: VIVIEN WATTS PROJECT DIRECTORY SCALE: N.T.S.9 870 SAN VICENTE DR. ARCADIA, CA 91007 PROJECT SITE SHEET GRID SCALE: N.T.S. LEGEND SCALE: N.T.S.12 VICINITY MAP SCALE: N.T.S.4 PROJECT DESCRIPTION BUILDING SUMMARY SCALE: NTS 10 APN 5776-026-011 ZONING R-1 (SINGLE FAMILY DWELLING) LOT SIZE 20,950 SF EXISTING HOUSE 3,403 SF + 447 SF GARAGE # OF GARAGES 1 FIRE SPRINKLER NO @ EXISTING HOUSE SCOPE OF WORK: 1. DETACHED ON-STORY ADU @ REAR YARD 594 SF 2. ATTACHED ONE-STORY WORKSHOP @ (E) 2-CAR GARAGE 288 SF DRAWING INDEX APPLICABLE CODES •2022 CALIFORNIA RESIDENTIAL CODE (CRC) •2022 CALIFORNIA PLUMBING CODE (CPC) •2022 CALIFORNIA MECHANICAL CODE (CMC) •2022 CALIFORNIA ELECTRIC CODE (CEC) •2022 CALIFORNIA ENERGY CODE (CENC) •2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN) NOTES SCALE: NTS 5 BUILDING CODE SUMMARY PROPOSED BUILDING AREA: OCCUPANCY GROUP: R-3/U CONSTRUCTION TYPE: V-B NOTE: PROVIDE A RAIN BARRIER INSTALLED AT THE UNDERSIDE SURFACE OF THE ROOF SHEATHINGS AND THE INSIDE SURFACE OF GABLE ENDS OR OTHER EXTERIOR VERTICAL SURFACE OF GABLE ENDS OR OTHER CALCULATIONS. CBEES 150.1(C)2& TABLE 150.1-A. NOTES: 1. ALL NONCOMPLIANT PLUMBING FIXTURES SHALL BE REPLACED WITH WATER- CONSERVING PLUMBING FIXTURE PRIOR TO FINAL INSPECTION. 2. THE ISSUANCE OF A PERMIT SHALL NOT PREVENT THE BUILDING OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS ON THESE PLANS OR FROM PREVENTING ANY VIOLATION OF THE CODES ADOPTED BY THE CITY, RELEVANT LAWS, ORDINANCES, RULES AND/OR REGULATIONS. 3. IF EXISTING FIRE SPRINKLERS ARE IN PLACE A SEPARATE FIRE DEPARTMENT PERMIT IS REQUIRED FOR THE MODIFICATION OF FIRE SPRINKLERS. PLANS SHALL STATE DEFERRED SUBMITTAL TO FIRE DEPARTMENT FOR FIRE SPRINKLERS. 4. THE ISSUANCE OF A PERMIT SHALL NOT PREVENT THE BUILDING OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS ON THESE PLANS OR FROM PREVENTING ANY VIOLATION OF THE CODES ADOPTED BY THE CITY, RELEVANT LAWS, ORDINANCES, RULES AND/OR REGULATIONS. 5. SEPARATE PERMIT SHALL FIRST BE OBTAINED FROM THE CITY PUBLIC WORKS DEPARTMENT PRIOR TO PLACEMENT OF ANY CONSTRUCTION MATERIALS OR EQUIPMENT IN THE PUBLIC WAY. AT TIME OF PERMIT ISSUANCE, CONTRACTOR SHALL SHOW THEIR VALID WORKERS' COMPENSATION INSURANCE CERTIFICATE. 6. ALL WORK SHALL CONFORM TO ALL REQUIREMENTS OF STATE OF CALIFORNIA TITLE 24 REGARDLESS OF THE INFORMATION INDICATED ON THESE PLANS. IT IS THE RESPONSIBILITY OF THE INDIVIDUAL SUPERVISING THE CONSTRUCTION TO ENSURE THAT THE WORK IS DONE IN ACCORDANCE WITH CODE REQUIREMENTS PRIOR TO REQUESTING INSPECTION. 7. EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR ANY OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTES ON SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTE. 8. SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE STABILIZED SO AS TO INHIBIT SEDIMENTS FROM BEING 9. DEPOSITED INTO THE PUBLIC WAY. ACCIDENTAL DEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN OR OTHER MEANS. 10. STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED MATERIALS MUST BE PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY THE FORCES OF WIND OR WATER. 11. TRASH AND CONSTRUCTION RELATED SOLID WASTES MUST BE DEPOSITED INTO A COVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND DISPERSAL BY WIND. 12. FUELS, OILS, SOLVENTS AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE WITH THEIR LISTING AND ARE NOT TO CONTAMINATE THE SOIL AND SURFACE WATERS. ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED INTO THE DRAINAGE SYSTEM. 13. SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) SHALL BE NOTIFIED IN ACCORDANCE WITH CALIFORNIA STATE LAW PRIOR TO START OF ANY DEMOLITION, ADDITION, AND/OR REMODEL WORK. THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT OFFICE IS LOCATED AT 21865 COPLEY DRIVE IN DIAMOND BAR, PHONE NO. (909) 396-2000. BE ADVISED, SCAQMD MAY REQUIRE A 10 DAY WAIT PERIOD PRIOR TO START OF WORK. 14. ALL NONCOMPLIANT PLUMBING FIXTURES SHALL BE REPLACED WITH WATER- CONSERVING PLUMBING FIXTURE PRIOR TO FINAL INSPECTION. 15. DUE TO THE POSSIBLE PRESENCE OF LEAD-BASED PAINT, LEAD-SAFE WORK PRACTICES ARE REQUIRED FOR ALL REPAIRS THAT DISTURB PAINT IN PRE-1979 BUILDINGS. FAILURE TO DO SO COULD CREATE LEAD HAZARDS THAT VIOLATE CALIFORNIA HEALTH & SAFETY CODE, SECTIONS 17920.10 AND 105256 WITH POTENTIAL FINES FOR VIOLATIONS UP TO $5,000 (SECTION (D) AMENDED) OR IMPRISONMENT FOR NOT MORE THAN 6 MONTHS IN THE COUNTY JAIL OR BOTH. SCALE: N.T.S.3 SCALE: N.T.S.1 SCALE: NTS 2 SITE PLAN SCALE: 3/32" = 1'-0"16 N STRUCTURAL ENGINEER: MEP CONSULTING ENGINEERS: JS ENGINEERING, INC. 410 S. SAN GABRIEL BLVD. #8, SAN GABRIEL, CA 91776 T/626.497.0558 CONTACT: JOSEPH ZHANG NB ENGINEERING, INC. 19119 COLIMA RD, UNIT 111 ROWLAND HEIGHTS, CA 91748 T/626.269.9321 CONTACT: JIAFENG GAO (N) WATER HEATER (N) CONDENSOR (E) AC UNIT (E) ELEC. PANEL (N) SUB ELEC. PANAL 5" / 12"5" / 12" 5" / 1 2 " BU I L D I N G L I N E 5" / 1 2 " ROOF ATTIC AREA: 814 S.F. REQUIRED: 814/ 150 = 5.42 S.F. X 144 = 781.44 SQ. IN PROVIDED: 4 X (12" X 24" EYEBROW VENT) = 4 X 100 = 400 SQ.IN PROVIDED: 9X (14" X 5" EAVE VENT) = 9 X 44 = 396 SQ.IN TOTAL = 796 SQ. IN > 781.44 SQ. IN D.S D.S D.S INTERIOR SWING DOORA B EXTERIOR SLIDING DOORCEXTERIOR SWING DOOR FINISH FLOOR LINE 7' - 0 " A DOUBLE SLIDING WINDOW B DOUBLE SLIDING WINDOW 3' - 0 " C1 FINISH FLOOR LINE C2 C2C1 3' - 0 " DDOUBLE SLIDING WINDOW DOUBLE SLIDING WINDOW DOUBLE SLIDING WINDOW 5' - 6 " 6' - 0 " 3' - 0 " D DOUBLE SINGLE HUNG WINDOW 2X6 WOOD STUD @ 16" O.C. 5/8" TYPE X GYPSUM BOARD INSULATION 5/8" TYPE X GYPSUM BOARD A 1 HR FIRE RATED WALL @ BOTH SIDE SCALE: 1 1/2 = 1' -0" EXTERIOR INTERIOR EXISTING TWO-CAR GARAGE NEW WORK SHOP 1/ 2 " / 1 2 " 1/ 2 " / 1 2 " ROLLED ROOFING TO MATCH EXISTING ROOF (N) WALL, TYP. (N) SHAKE OVERHANG TO MATCH EXISTING, TYP. D.SD.S GUTTER LEGEND: D.S. DOWNSPROUT BRAVA SHAKE TILES WEATHEROMETER PASS FIRE RESISTANCE CLASS A IMPACT RESISTANCE CLASS 4 WIND RESISTANCE APPROVED TO WITHSTAND WIND SPEEDS OF UP TO 188MPH WITH RING SHANK NAILS AND UP TO 211MPH WITH HIGH WIND / SCREW INSTALLATION. UPLIFT BEND PASS TEMPERATURE-CYCLING PASS PENETRATION PASS NOTES: 1. ALL COLOR AND MATERIALS OF ALL PROPOSED WALLS , ROOFS, TRIMS, WINDOWS, DOORS, AND ARCHITECTURAL FEATURES TO MATCH EXISTING. 2. ROOF COVERING INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER’S INSTALLATION INSTRUCTION. DATE: REVISED: M- S I T U D E S I G N L L C PR O J E C T N A M E : APPROVAL STAMP: PROJ. NO: CO N S U L T A N T : SHEET TITLE: SHEET NO: 2024 M-SITU DESIGN LLC 24.01.15 T. 6 2 6 . 3 1 0 . 2 7 2 8 E. m s i t u . s t u d i o @ g m a i l . c o m A. 4 7 8 6 P E C K R O A D , # A , E L M O N T E , C A 9 1 7 3 2 MA N D Y S I T U A2.3 ROOF PLAN, DOOR & WINDOW SCHEDULES 2023-30 87 0 S A N V I C C E N T E R D . AR C A D I A , C A 9 1 0 0 7 1/4" = 1'-0" ROOF PLAN - ADU15B DOOR SCHEDULE DOOR NO. TYPE MARK SIZE THICKNESS REMARK D.1 O 5' - 0" X 7' - 0" 0' - 2" D.2 Q 2' - 8" X 7' - 0" 0' - 1 3/8" D.3 O 5' - 0" X 7' - 0" 0' - 2" D.4 A 2' - 8" X 7' - 0" 0' - 1 3/8" D.5 A 2' - 8" X 7' - 0" 0' - 1 3/8" D.6 A 2' - 8" X 7' - 0" 0' - 1 3/8" D.8 A 2' - 8" X 7' - 0" 0' - 1 3/8" WINDOW SCHEDULE WINDOW NO.MARK SIZE Window Glazing U-Value Window Glazing SHGC Comments W.1 A 5' - 0" X 4' - 0" 0.30 0.23 W.2 B 3' - 0" X 1' - 6" 0.30 0.23 W.3 C 4' - 0" X 2' - 0" 0.30 0.23 W.4 D 3' - 6" X 4' - 0" 0.30 0.23 W.8 D 3' - 6" X 4' - 0" 0.30 0.23 3 DOOR SCHEDULE SCALE: NTS WINDOW SCHEDULE SCALE: NTS 2 NOTES: 1. EMERGENCY AND ESCAPE RESCUE OPENINGS SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5.7 SQUARE FEET (0.530 M2). THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. THE NET CLEAR HEIGHT OF THE OPENING SHALL BE NOT LESS THAN 24 INCHES (610 MM) AND THE NET CLEAR WIDTH SHALL BE NOT LESS THAN 20 INCHES (508 MM). 2. THE NFRC TEMPORARY LABEL DISPLAYED ON WINDOWS MUST REMAIN ON THE UNIT UNTIL FINAL INSPECTION HAS BEEN COMPLETED. 3. WINDOWS AND GLAZED DOORS SHALL BE DUAL GLAZED AND THE WINDOW U-FACTOR AND SHGC MUST BE INDICATED ON THE SCHEDULE. 4. THE NFRC TEMPORARY LABEL DISPLAYED ON WINDOWS MUST REMAIN ON THE UNIT UNTIL FINAL INSPECTION HAS BEEN COMPLETED. WINDOW & DOOR NOTES: 1. DIRECTION OF OPERATION IS SHOWN THE EXTERIOR. 2. ALL GLASS LITES IN DOORS AND SIDELITES TO BE TEMPERED. 3. EACH UNIT OF TEMPERED GLASS SHALL BE PERMANENTLY IDENTIFIED BY MANUFACTURER. THE IDENTIFICATION SHALL BE EATCHED OR CERAMIC FIRED ON THE GLASS AND BE VISIBLE WHEN THE UNIT IS GLAZED. 4. SAFETY GLAZING IS REQUIRED AT THE FOLLOWING LOCATIONS: A. WINDOWS LOCATED IN TUB AND SHOWER AREAS WHEN THE STILL HEIGHT IS LESS THAN 60 INCHES ABOVE SHOWER OR TUB DRAIN INLET. B. GLAZING IN PANELS HAVING AN AREA IN EXCESS OF 9 SQUARE FEET AND THE LOWER EDGE LESS THAN 18 INCHES AND THE LOWER EDGE LESS THAN 18 INCHES ABOVE A WALKING SURFACE WITHIN 36 INCHES. C. GLAZING IN GRASS AND EGRESS DOORS D. WINDOW LOCATED WITHIN 24" OF A DOOR AND WHERE THE BOTTOM EXPOSED EDGE IS LESS THAN 60" ABOVE WALKING SURFACE 5. IN EVERY BEDROOM, PROVIDE ON OPERABLE ESCAPE WINDOW MEETING ALL THE FOLLOWING: AN OPERABLE AREA OF NOT LESS THAN 5.7 SQ, A MINIMUM CLEAR 24IN. HEIGHT AND 20IN. WIDTH, AND A STILL HEIGHT NOT OVER 44IN. ABOVE THE FLOOR. 6. WINDOW TO BE MILGARD 710/910/911 ALUMINUM SERIES OR EQUAL. 7. WINDOW TO BE FLEETWOOD SERIES 2000 OR EQUAL. 8. PROVIDE OPTIONAL SPRING LATCH AND EXTENSION POLE. NOTES SCALE: NTS 4SCALE: N.T.S.12WALL SECTION DETAIL SCALE: 1/4" = 1'-0"15 WINDOW FLASHING DETAIL SCALE: N.T.S.20 DOOR FLASHING DETAIL SCALE: N.T.S.16 ROOF PLANS 3/16" = 1'-0" ROOF PLAN - WORKSHOP15A (E) 2-CAR GARAGE B.O. CEILING 10' -8" (N) WORKSHOP B.O. CEILING 11' -0" T.O. ROOF @ WORKSHOP 12' -4" (E) 2-CAR GARAGE B.O. CEILING 10' -8" (N) WORKSHOP B.O. CEILING 11' -0" T.O. ROOF @ WORKSHOP 12' -4" (E) 2-CAR GARAGE B.O. CEILING 10' -8" (N) WORKSHOP B.O. CEILING 11' -0" T.O. ROOF @ WORKSHOP 12' -4" (N) WORKSHOP B.O. CEILING 11' -0" EXISTING TWO-CAR GARAGE NEW WORK SHOP T.O. ROOF @ WORKSHOP 12' -4" FINISH FLOOR 0' -0" (N) WORKSHOP B.O. CEILING 11' -0" NEW WORK SHOP T.O. ROOF @ WORKSHOP 12' -4" DATE: REVISED: M- S I T U D E S I G N L L C PR O J E C T N A M E : APPROVAL STAMP: PROJ. NO: CO N S U L T A N T : SHEET TITLE: SHEET NO: 2024 M-SITU DESIGN LLC 24.01.15 T. 6 2 6 . 3 1 0 . 2 7 2 8 E. m s i t u . s t u d i o @ g m a i l . c o m A. 4 7 8 6 P E C K R O A D , # A , E L M O N T E , C A 9 1 7 3 2 MA N D Y S I T U A2.5 WORKSHOP _ BUILDING ELEVATIONS & SECTIONS 2023-30 87 0 S A N V I C C E N T E R D . AR C A D I A , C A 9 1 0 0 7 SCALE 1/4" = 1'-0"14WEST BUILDING ELEVATION SCALE 1/4" = 1'-0"13EAST BUILDING ELEVATION SCALE 1/4" = 1'-0"1SOUTH BUILDING ELEVATION SCALE 1/4" = 1'-0"2BUILDING SECTION A-A SCALE 1/4" = 1'-0"5BUILDING SECTION B-B LEGEND 1" TICK, 3-LAYERS EXTERIOR STUCCO PAINTED W/ PRIMER, BROWN COAT, SCRATCH COAT, EXPANDED METAL LATH, 2-PLY GRADE D BUILDING PAPER & 5/8" DENSE GLASS SHEATHINGS. PROVIDE WEEP SCREED 2" MIN. TO PAVEMENT & 4" MIN. TO GROUND, AND CORNER BEARDS AT ALL CORNERS & EDGES EXTERIOR SMOOTH STUCCO PAINT COLOR: TO MATCH EXISTING FASCIA/ EXTERIOR DOOR/ TRIM PAINT COLOR: WHITE TO MATCH EXISTING ASPHALT COMPOSITE ROOF SHINGLES, CLASS A, OWEN CORING OAKRIDE ALGAE RESISTANT ESTATE GRAY LAMINATE ASPHALT SHINGLES, OR EQUAL INSTALLATION SHALL BE IN ACCORDANCE WITH MFG'S SPECIFICATIONS. (MATCH EXISTING) UL ER2453-01; UL ER =2453-02 ICC-ES AC438 FM 4474 CRRC RATED PROGRAM APPROVED ASTM E108/UL 790 (CLASS A FIRE RESISTANCE) ASTM D228 ASTM D3018 (TYPE 1) ASTM D3462 ASTM D7158 (CLASS H WIND RESISTANCE) NOTES: 1.ALL COLOR AND MATERIALS OF ALL PROPOSED WALLS , ROOFS, TRIMS, WINDOWS, DOORS, AND ARCHITECTURAL FEATURES TO MATCH EXISTING. 2.ROOF COVERING INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER’S INSTALLATION INSTRUCTION. 3.ALL NEW ROOF MATERIALS, SEE DETAILS 10 &11/A0.1 4.EXTERIOR COLORS AND MATERIALS OF THE PROPOSED ADDITION, INCLUDING WALLS, ROOF, AND WINDOWS MUST MATCH THE EXISTING STRUCTURE