HomeMy WebLinkAboutPlansSHEET INDEX GENERAL INFORMATION ON PROPERTY & LEGAL DESCRIPTION OF PROPERTY NOTES SCOPE OF WORK NOTES: 1. The construction shall not restrict a five-foot clear and unobstructed access to any water or power distribution facilities (Power poles, pull-boxes, transformers, vaults, pumps, valves, meters, appurtenances, etc.) or to the location of the hook-up. The construction shall not be within ten feet of any power lines-whether or not the lines are located on the property. Failure to comply may cause construction delays and/or additional expenses. 2. An approved Seismic Gas Shut Off Valve or Excess Flow Shut Off Valve will be installed on the fuel gas line on the down-stream side of the utility meter and be rigidly connected to the exterior of the building or structure containing the fuel gas piping.@ (Per Ordinance 170,158 and 180,670) (Includes Commercial additions and TI work over $10,000.) Separate plumbing permit is required. 3. Provide ultra-flush water closets for all new construction. Existing shower heads and toilets must be adapted for low water consumption. 4. Provide (70) (72) inch high non absorbent wall adjacent to shower and approved shatter resistant materials for shower enclosure.@ (1210.2.3, 2406.4.5, R307.2, R308.4) 5. Water heater must be strapped to wall. (Sec. 507.3 & LAPC) 6. A fire alarm (visual and audible) system is required. The alarm system must be approved by the Fire Department and Electrical Plan Check prior to installation. (LAMC 57.122) 7. Carbon monoxide alarm is required per (Sec. 420.6, R315) 8. Footings of foundations for buildings and structures founded on expansive soils shall be designed per 1808.6. Existing footings supporting new loads shall also comply. Scale As Noted Drawn by AK Date 03-01-2024 DR A F T I N G & D E S I G N S E R V I C E S Ag n i e s z k a K a l e t a L o p e z 24 5 5 E . O r a n g e G r o v e B l v d . Pa s a d e n a , C A 9 1 1 0 4 Ph o n e 8 1 8 - 5 2 2 - 9 1 8 7 A0 PL O T P L A N Address: 919 N 1st Ave Arcadia, CA 91006 APN: 5772 - 002 - 014 TRACT # 7820 VAC ALLEY ADJ ON W AND S 5 FT EX OF ST OF LOT 19 AND VAC ALLEY ADJ ON W AND EX OF ST LOT 20 AND VAC ALLEY ADJ ON W AND N 15 FT EX OF ST OF LOT 21 Year Built 1938 Zone Construction VB Fire Sprinklers - existing - No proposed - No LOT SIZE: 5,760 SF EXISTING HOUSE 1,128 SF PROPOSED REAR ADDITION 344 SF TOTAL 1,472 SF EXISTING GARAGE 162 SF To be converted to Junior Accessory Dwelling Unit PROPOSED JADU 162 SF CONSULTANTS A0 PLOT PLAN A1 FLOOR PLANS A2 ELEVATIONS A3 SECTIONS & ROOF PLAN A4 DETAILS Addition to the rear of the Single Family Residence and Garage to JADU conversion THE CONSTRUCTION WILL COMPLY WITH THE CODES IN EFFECT AT THE TIME THE APPLICATION IS ACCEPTED. 2022 California Building Code 2022 California Residential Code 2022 California Electrical Code 2022 California Mechanical Code 2022 California Plumbing Code 2022 California Energy Code 2022 California Green Building Standards Code 2023 City of Arcadia Amendments VICINITY N.T.S. Owner:Gilbert Gazanian 919 N 1st Ave Arcadia, CA 91006 Designer: Agnieszka Kaleta 2455 E. Orange Grove Blvd. Pasadena, CA 91104 (818 522 9187) Structural Engineer: Contractor: TBD Title 24:Energy Consult LLC 411 N. Harbor Blvd. Ste. # 205 San Pedro, California, 90731 www.title24ez.com (424 247 7658) REVISION 1S T A V E N U E 24'-6" 43'-2" LEGEND: PROPERTY LINE EXISTING BUILDING (E) FENCE SCALE 1/8"= 1'0" PLOT PLAN 919 N 1st Ave Arcadia, CA 91006 34 ' - 2 " 50'-8" 7' - 1 0 " 12'-6" 34'-1" 9' - 7 " 10 ' - 4 " 6' - 5 " 25 ' - 2 " 9' - 0 " 7' - 0 " 3' - 1 0 " 4'-9" 7' - 0 " ADDITION TO SFR 23 ' - 5 " 12'-8" 10 ' - 0 " 18'-0" AD D I T I O N & G A R A G E TO J A D U C O N V E R S I O N 91 9 N 1 s t A v e A r c a d i a , C A 9 1 0 0 6 GARAGE to JADU CONVERSION 20'-0" 10 ' - 0 " Fruit tree 1S T A V E N U E 919 N 1st Ave Arcadia, CA 91006 GARAGE to JADU CONVERSION (E)CONC., COVERED PATIO EXISTING PLOT PLANSCALE 1/16"= 1'0" Pittosporum tobira (E) Chinese elm DBH = ~30" H = ~40' Condition - Good All existing trees are located away from the proposed construction and will not be impacted by this construction DBH - Diameter at breast height (DBH) measured at 4 1⁄2 feet above the point where the trunk meets the ground (E) California sycamore DBH = 2 x ~25" H = ~45' Condition - Good A1 Scale As Noted Drawn by AK FL O O R P L A N S DR A F T I N G & D E S I G N S E R V I C E S Ag n i e s z k a K a l e t a L o p e z 24 5 5 E . O r a n g e G r o v e B l v d . Pa s a d e n a , C A 9 1 1 0 4 Ph o n e 8 1 8 - 5 2 2 - 9 1 8 7 Date 03-01-2024 NOTES TO ALL SCHEDULES: 1. CONTRACTOR TO VERIFY ALL ROUGH OPENING SIZES AND ALL WINDOW AND DOOR SIZES AND TYPES PRIOR TO ORDERING. 2. ALL INTERIOR AND EXTERIOR DETAILS, FINISHES AND COLORS TO VERIFY WITH OWNER. 3. THE NFRC TEMPORARY LABEL DISPLAYED ON WINDOWS AND SKYLIGHTS (INCL. TUBULAR) MUST REMAIN ON THE UNIT UNTIL FINAL INSPECTION HAS BEEN COMPLETED. DOOR SCHEDULE #Size Description Door Material Finish 9'-0" x 6'-8"D1 Wood/Glass Stain/Paint D2 D3 2'-8" x 6'-8"Wood Stain/Paint Stain/Paint W Size H# WINDOW SCHEDULE Description Material Finish Glazing W1 8'-0" x 2'-2" (verify)Paint 2xW2 Paint Dual Glazing, Low E Wood or Vinyl Provide emergency egress from sleeping rooms. Min.- 24" clear ht, 20" clear width a. A net clear opening area of not less than 5.7-SF, when above the grade-floor and 5 SF, when on the grade-floor. b. A minimum clear height of 24-in. c. A minimum clear width of 20-in. d. The bottom of the clear opening not greater than 44-in. measured from the finish floor. Safety glazing (tempered glazing) is required for the following: a)Where the glazing is within 24" of either side of the door in the plane of the door in a closed position and where the bottom edge of the glazing is less then 60" above the door (CRC R308.4.2 item 1) b)Where the glazing is on a wall perpendicular to the plane of the door in a closed position and -Within 24" of the hinge side of an in-swinging door (CRC R308.4.2 item 2) -Glazing less than 60" above a shower or tub floor (CRC R308.4.5) c)Glazing where the bottom edge is less than 36" above the stairways, landings, and ramps (CRC R308.4.6) d)Glazing adjacent to the stairway bottom landing where the glazing is less then 36" above the landing and within 60" horizontal arc less then 180 degrees from the ottom tread nosing shall be safety glazing (CRC R308.4.7) 3'-0" x 6'-8" Casement SD CM KEY NOTES 1. HARDWIRE SMOKE DETECTORS SHALL BE INTERCONNECTED HARD-WIRED WITH BATTERY BACKUP AND SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72.. a) CARBON MONOXIDE ALARM - SHALL BE INTERCONNECTED HARD-WIRED WITH BATTERY BACK UP. 2. A 72" HIGH NON-ABSOBENT WALL SURFACE IN BATHTUB & SHOWER COMPARTMENTS. (CRC R307.2) 3. GLAZING WITHIN 60" OF STAIR AND STAIR LANDING, WHEN BOTTOM EDGE IS WITHIN 18" OF THE FLOOR, WITHIN 60" OF TUB OR SHOWER FLOOR, SHALL BE TEMPERED. (CRC R308.4) 4. MECHANICAL EXHAUST Fans shall be ENERGY STAR compliant and be ducted to terminate to the outside of the building. Fans, not functioning as a component of a whole house ventilation system, must be controlled by a humidity control. Fans, not functioning as a component as a whole house ventilation system must be controlled by a humidity control. 5. ALL INTERIOR AND EXTERIOR STAIRWAYS SHALL BE ILLUMINATED (R312.3) 6. New High Efficiency Faucets. Installed per manufacturer specifications. 7. Heater shall be capable of maintaining a minimum room temperature of 68°F at a point 3 feet above the floor and 2 feet from exterior walls in all habitable rooms at the design temperature. R303.10 FAN Remarks Remarks 3'-0" x 3'-6"Casement Sliding Tempered Panel Door Tempered Tempered REVISION U-FACTOR/SHGC 0.32 / 0.24 U-FACTOR /SHGC 0.32 / 0.24 100 CFM hood 32' 9' 13 ' - 5 " 10 ' - 2 " 11' 1' - 7 " 10 ' - 4 " 8' - 9 " 10'-9" 4'-6" 8' - 9 " 10 ' - 2 " 5' - 2 " 7'-3" 12' 13 ' - 1 " 3'-10" 7' - 6 " W=(E) 6'-0" H=(E) 4'-8" W=(E) 3'-0" H=(E) 4'-8" W=(E) 3'-4" H=(E) 2'-8" W=(E) 5'-10" H=(E) 3'-10" (E) KITCHEN (E) GARAGE (E ) L A U N D R Y (E)BEDROOM (E) BATH (E) BATH (E) BEDROOM 5' 9' - 9 " 6' - 5 " 12' (E ) F. P . (E)PORCH W=(E) 3'-0" H=(E) 2'-3" W=(E) 2'-0" H=(E) 2'-6"W=(E) 2'-10" H=(E) 4'-8" W=(E) 2'-10" H=(E) 3'-6" (E ) C L O S E T (E ) C L O S E T (E) LIVING ROOM (E) DINING ROOM (E ) E N T R Y W=(E) 2'-10" H=(E) 4'-8" 50'-6" 7' - 8 " 11 ' - 2 " 3' - 9 12" 10 ' 9' EXISTING FLOOR PLAN scale 1/4"=1'-0" 9' - 6 " 34' 12'-6" W=(E) 3'-0" H=(E) 4'-8"(N) JUNIOR ACCESSORY DWELLING UNIT 9' PROPOSED FLOOR PLAN scale 1/4"=1'-0" LEGEND EXISTING TO BE DEMOLISHED PROPOSED 18'9' 9' 13 ' - 5 " 10 ' - 2 " 11' 1' - 7 " 10'-9" (E) 4'-6" 8' - 9 " 5' - 2 " 7'-3" 12' 13 ' - 1 " 3'-10" 7' - 6 " W=(E) 3'-4" H=(E) 2'-8" (E)BEDROOM (E) BATH (E) BATH (E) BEDROOM 12' (E ) F. P . W=(E) 3'-0" H=(E) 2'-3" W=(E) 2'-0" H=(E) 2'-6"W=(E) 2'-10" H=(E) 4'-8" W=(E) 2'-10" H=(E) 3'-6" (E ) C L O S E T (E ) C L O S E T (E ) E N T R Y W=(E) 2'-10" H=(E) 4'-8" (E ) 7 ' - 8 " 11 ' - 2 " 3' - 9 12" 7' 10 ' DW W/DTall cabinet 3' 3'Pantry 3' 2' (N) KITCHEN 7'-6" 2' 6' - 2 " 7' - 2 " 1' 4'-21 2"2' Ref (N) FAMILY ROOM A A3 A A3 B A3 18' 3' Ki t c h e n e t t e +1/2" 3' 3'-6" (E) LIVING ROOM 7' - 1 1 " 7' - 1 1 " 3' 31 ' 12' (E ) 6 ' - 3 12" 12'-6"6'-2" 7'7'-6"13'-6" 10 ' (E ) 3 4 ' 17'-1" D1 W1 W2 3' - 1 1 " W=(E) 6'-0" H=(E) 4'-8" (E)CONC. COVERED PATIO D2 D3 W=(E) 3'-0" H=(E) 6'-8"W=(E) 3'-0" H=(E) 6'-8" W=(E) 2'-6" H=(E) 6'-8" (E) LAUNDRY W=(E) 2'-6" H=(E) 6'-8" Front Door Tempered0.32 / 0.24Wood/Glass SD CM SD CM SD SD (E) Attic access AD D I T I O N & G A R A G E TO J A D U C O N V E R S I O N 91 9 N 1 s t A v e A r c a d i a , C A 9 1 0 0 6 B A3 (E) Attic access (N) 22'X30 Attic access Ref hot plate (E) -5" -1/2" min.3' Landing W2 3' - 6 12" C L W3 Eq Eq W3 Paint2'-10" x 3'-6"Casement Tempered W=(E) 2'-10" H=(E) 4'-8"EXISTING TO REMAIN W#D#PROPOSED Verify to match (E) +(E) +~4" (max. 7 34") Existing HVAC & W/H to accommodate JADU A2 Scale As Noted Drawn by AK DR A F T I N G & D E S I G N S E R V I C E S Ag n i e s z k a K a l e t a L o p e z 24 5 5 E . O r a n g e G r o v e B l v d . Pa s a d e n a , C A 9 1 1 0 4 Ph o n e 8 1 8 - 5 2 2 - 9 1 8 7 REVISION EL E V A T I O N S AD D I T I O N & G A R A G E TO J A D U C O N V E R S I O N 91 9 N 1 s t A v e A r c a d i a , C A 9 1 0 0 6 6" 2" 6" 2" EXISTING FRONT (EAST) ELEVATION scale 1/8"=1'-0" PROPOSED NORTH ELEVATION scale 1/4"=1'-0" EXISTING NORTH ELEVATION scale 1/8"=1'-0" EXISTING WEST ELEVATION scale 1/8"=1'-0" EXISTING SOUTH ELEVATION scale 1/8"=1'-0" PROPOSED SOUTH ELEVATION scale 1/4"=1'-0" Date 03-01-2024 1' 4" PROPOSED FRONT (EAST) ELEVATION scale 1/8"=1'-0" PROPOSED WEST ELEVATION scale 1/8"=1'-0" 1' 4" (E ) 1 5 ' (E ) 1 5 ' 14 ' - 7 " 13 ' - 7 12" EXTERIOR MATERIAL & FINISH SCHEDULE B -- A -- C -- (E & N) CLASS "A" ROOFING TO MATCH EXIST. D -- NEW DOORS & WINDOWS (E & N) THREE-COAT STUCCO. PAINT TO MATCH EXISTING. D -- NEW FIBER CEMENT BOARDS - HardiePlans B -- C -- D -- B -- C -- D -- B -- C -- A -- B -- C -- In areas where expansive or collapsible soils are known to exist, all dwellings shall have a controlled method of water disposal from roofs or rain tanks that will collect and discharge roof drainage to the ground surface not less than 5 feet from foundation walls or to an approved drainage system. R801.3 DR A F T I N G & D E S I G N S E R V I C E S Ag n i e s z k a K a l e t a L o p e z 24 5 5 E . O r a n g e G r o v e B l v d . Pa s a d e n a , C A 9 1 1 0 4 Ph o n e 8 1 8 - 5 2 2 - 9 1 8 7 A3 Scale As Noted Drawn by AK SE C T I O N S & RO O F P L A N S NOTES ALL ROOFS: 1. ~ 766 SF New Class A Roofing to match exiting, INSTALLED PER MANUFACTURE SPEC. -FOR ROOF SLOPES < 2:12: SRI VALUE OF AT LEAST 78 OR BOTH A 3-YEAR SOLAR REFLECTANCE OF AT LEAST 0.65AND A THERMAL EMITTANCE OF AT LEAST 0.85. -FOR ROOF SLOPES >2:12: SRI VALUE OF AT LEAST 20 OR BOTH A 3-YEAR SOLAR REFLECTANCE OF AT LEAST 0.25 AND A THERMAL EMITTANCE OF AT LEAST 0.75. 2. NEW RAIN GUTTERS AND DOWNSPOUTS. EXISTING TO BE REPLACED OR FIXED IF NEEDED. ROOF GUTTERS MUST BE PROVIDED WITH MEANS TO PREVENT THE ACCUMULATION OF LEAVES AND DEBRIS IN THE GUTTER (Residential Code E327.534 and Building Code 705A.4) Unless roofs are sloped to drain over roof edges, roof drains shall be installed at each low point of the roof. Where required for roof drainage, scuppers shall be placed level with the roof surface in a wall or parapet. The scupper shall be located as determined by the roof slope and contributing roof area. When gutters and leaders are placed on the outside of buildings, the gutters and leaders shall be constructed of metal or approved plastic for outdoor exposure with lapped, soldered or caulked joints and shall be securely fastened to the building with a corrosion resistant fastening device of similar or compatible material to the gutters and downspouts. R903.4.1 Overflow Drains and Scuppers When other means of drainage of overflow water is not provided, overflow scuppers shall be placed in walls or parapets not less than 2 inches (51 mm) nor more than 4 inches (102 mm) above the finished roof covering and shall be located as close as practical to required vertical leaders or downspouts or wall and parapet scuppers. An overflow scupper shall be sized in accordance with the Florida Building Code, Plumbing. Overflow drains shall discharge to an approved location and shall not be connected to roof drain lines. ATTIC VENTS SHALL MET THE FOLLOWING: B) THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN: I. 1/150 OF THE ATTIC SPACE OR II. 1/300 PROVIDED A CLASS I OR II VAPOR BARRIER IS INSTALLED ON THE WORM SIDE OF THE CEILING OR III. 1/300 PROVIDED AT LEAST 50% AND NOT MORE THAN 80%OF THE REQUIRED VENTILATION AREA MUST BE LOCATED AT LEAST 3 FEET ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE PROVIDED BY EAVE OR CORNICE VENTS. C) OPENINGS SHALL HAVE CORROSION-RESISTANT WIRE MESH OR OTHER APPROVED MATERIAL .Opening shall be 1/16 inches minimum and 1/8 maximum D) A MINIMUM OF 1 INCH AIRSPACE SHALL BE PROVIDED BETWEEN INSULATION AND ROOF SHEETING. Roof and attic vents shall resist the intrusion of flame and embers into the attic area of the structure, or shall be protected by corrosion resistant, noncombustible wire mesh with 1/16” min., 1/8” max. openings or its equivalent [CRC R327.8.2]. Eaves and soffits shall meet the requirements of SFM 12-7A-3 or shall be protected by ignition-resistant materials or noncombustible construction on the exposed underside [CRC R327.8.3]. 5. WHERE THE ROOF PROFILE ALLOWS A SPACE BETWEEN THE ROOF COVERING AND ROOF DECKING, THE SPACE SHALL BE CONSTRUCTED TO PREVENT THE INTRUSION OF FLAMES AND EMBERS, cBE FIRE-STOPPED WITH APPROVED MATERIALS OR HAVE ONE LAYER OF NO. 72 ASTM CAP SHEET INSTALLED OVER THE COMBUSTIBLE DECKING [CRC R327.5.2]. 6. Enclosed framing in wood exterior balconies and decks shall be provided with openings that provide a net free cross ventilation area not less than 1/150 of the area of each separate space. CBC Section 2304.12.2.6, as amended by emergency building standards (see A4b Notes) All Attic Area = 1,634 SF / 150 = 11 SF = 1,584 Sq Inch - 16 Vents Total 12x24 Dormer Vents W/1/8" Screen. STDH24GB, N.F.V. = 100 Sq/In. Color to match roof tile, EXISTING ROOF PLAN scale 1/8"=1'-0" 8' Ma t c h e x i s t i n g (N) ADDITION PROPOSED ROOF PLAN scale 1/4"=1'-0" Date 03-01-2024 (E ) 4 : 1 2 (E ) 4 : 1 2 (E)4:12 (E)4:12 (E ) 4 : 1 2 4: 1 2 Ma t c h e x i s t . 4: 1 2 Ma t c h e x i s t . 4:12 Match exist.B A3 A A3 A A3 (E) ATTIC 8' Ma t c h e x i s t i n g (E) BATH (N) ADDITION (N) ATTIC SECTION A-A scale 1/4"=1'-0" AD D I T I O N & G A R A G E TO J A D U C O N V E R S I O N 91 9 N 1 s t A v e A r c a d i a , C A 9 1 0 0 6 (N) CLASS "A" ROOFING to match exist. (N) UNERLAYMENT (E &N) RAFTERS & PLYWOOD (E& N) R30 INSULATION (E) CEILING (N) CLASS "A" ROOFING (to match exist.) (N) UNERLAYMENT (N) T&G or Plywood (N) RAFTERS per Structural (N) R30 INSULATION (N) DRYWAL 1' (E)4" LEGEND EXISTING PROPOSED Extend new roof over the existing flat roof @ exist. bath (N) Flooring (E&N) Concrete Slab per Structural Aggregate (N) JADU (N) Flooring (N) Waterproofing (E) Concrete Slab Existing Proposed Existing R13 R13 (N) ATTIC Proposed (exist. slab to be used if possible, new foundation) (E) LAUNDRY (N) KITCHEN SECTION B-B scale 1/4"=1'-0" (N) CLASS "A" ROOFING to match exist. (N) UNERLAYMENT (E &N) RAFTERS & PLYWOOD (E& N) R30 INSULATION (E) CEILING (N) CLASS "A" ROOFING (to match exist.) (N) UNERLAYMENT (N) T&G or Plywood (N) RAFTERS per Structural (N) R30 INSULATION (N) DRYWAL (E & N) Flooring (E) Raised Foundation (N) Flooring (N) Waterproofing (E & N) Concrete Slab (E ) 1 5 ' DR A F T I N G & D E S I G N S E R V I C E S Ag n i e s z k a K a l e t a L o p e z 24 5 5 E . O r a n g e G r o v e B l v d . Pa s a d e n a , C A 9 1 1 0 4 Ph o n e 8 1 8 - 5 2 2 - 9 1 8 7 2" MIN 4" M I N STUCCO COATS - SCRATCH, BROWN & FINISH METAL LATH 2x TYPE "D" BUILDING PAPER 312" FLANGE WEEP SCREED 26 GAUGE MIN. PAVED SURFACE GRADE FLOOR FOUNDATION INSIDE SURFACE OF WINDOW FLANGE THE BEAD OF SEALANT ON THE MOUNTING FLANGE AT THE SILL MUST HAVE AT LEAST 2 GAPS AT LEAST 2 INCHES WIDE TO PERMIT DRAINAGE. THE GAPS MUST BE NO MORE THAN 4-FEET APART. APPLY A CONTINUOUS BEAD OF SEALANT AROUND THE FULL PERIMETER OF THE BACK SIDE (INTERIOR SURFACE) OF THE WINDOW MOUNTING FLANGE. FLASHING TAPE OR ADHESIVE BACKED FLASHING (MUST MEET AC148 OR AAMA 711) SEALED OVER WINDOW FLANGES AT JAMBS SEALANT* FLASHING STRETCH TAPE SHIMS FROM THE INTERIOR, INSTALL LOW PRESSURE POLYURETHANE FOAM BETWEEN WINDOW AND ROUGH OPENING TO MAINTAIN CONTINUITY OF THE AIR BARRIER. IF GAP IS TOO NARROW TO ALLOW FOR USE OF POLYURETHANE, USE A CAULK SEALANT COMPATIBLE WITH FLASHINGS AT THE SILL AND THE JAMBS. IF ZIP SYSTEM® TAPE IS USED AT THE SILL AND THE JAMBS, COMPATIBLE SEALANTS ARE POLYURETHANE, BUTYL, AND SILICONE. INSTALLED WINDOW JAMB FLANGE FLASHING TAPE NOT TO EXTEND PAST THE MID-POINT OF HEAD FLANGE FLASHING TAPE FLASHING TAPE CAULKING INSTALL TYVEKÒ FLEXWRAPÔ AROUND PERIMETER OF OPENING LAP & TAPE TYVEKâ AT JOINTS (UPPER SHEET OVER LOWER SHEET) MINIMALLY EXPANDING POLYURETHANE FOAM OR APPROVED CAULK (AROUND WINDOW RSO) WRAP TYVEKâ INTO OPENING & TAPE TO SILL (ESP. @ CORNERS) USING TYVEKÒ FLEXWRAPÔ WINDOW WITH INTEGRAL MOUNTING FLANGE TYPICAL WALL FINISH COAT BROWN COAT SCRATCH COAT WIRE LATH WEATHER RESISTIVE BARRIER (TYVEKâ HOMEWRAPâ RECOMMENDED) TYVEKâ STUCCOWRAPâ SHEATHING 2"x6" WOOD STUDS w/ R-19 BATT INSULATION VAPOR RETARDER 1/2" GYPSUM BOARD FASTEN TYVEKÒ FLEXWRAPÔ CORNER USING MECHANICAL FASTENER A4 Scale As Noted Drawn by AK DE T A I L S 12" LAP 2 CONTINUOUS BEADS OF CAULK AT LAPS FASTEN THROUGH VALLEY CONTINUOUS SOLID SHEATHING TEE-CLIPS; DO NOT USE BERRIDGE TEE-PANEL DO NOT RUN REVISION 11-17-2023 1 AD D I T I O N & G A R A G E TO J A D U C O N V E R S I O N 91 9 N 1 s t A v e A r c a d i a , C A 9 1 0 0 6 Date 03-01-2024