Loading...
HomeMy WebLinkAboutPlansFH WM EP WH GM AC 21 ' - 2 " 25'-5" 4' - 7 " 24'-3" PROPERTY LINE: 125' (E) DRIVEWAY (E ) S I D E W A L K (E) LANDSCAPE PROPERTY LINE: 105' P R O P E R T Y L I N E : 6 5 . 9 ' P R O P E R T Y L I N E : 4 5 . 9 ' P R O P E R T Y L I N E : 3 1 . 4 2 ' (E) SIDEWALK (E) LANDSCAPE (E ) W A L K W A Y (E) A.C. (E) W.H. (E) E.P. (E) W.M. (E) G.M. (E) GARAGE 412 S.F.(E) SFD 1,813 S.F. (E) F.H. FH WM GM AC W.H. TANKLESS EP WH (E) 6'H CMU BL0CK WALL PROPERTY LINE: 125' 4:12 SLOPE TO MATCH (E) SFD EXTERIOR WALL LINE ROOF LINE (E) DRIVEWAY (E ) S I D E W A L K (E) A.C. (N) W.H. TANKLESS (E) LANDSCAPE AREA OF WORK SFD ADDITION = 242 S.F. 1' - 6 " EA V E U. N . O . PROPERTY LINE: 105' P R O P E R T Y L I N E : 6 5 . 9 0 ' (E ) 6 ' H W O O D F E N C E 7'6" x 6' LANDING (N) CONC. WALKWAY P R O P E R T Y L I N E : 4 5 . 9 0 ' P R O P E R T Y L I N E : 3 1 . 4 2 ' (E) SIDEWALK (E) LANDSCAPE (E) LANDSCAPE 4' - 7 " 3' - 1 " 21 ' - 2 " 19 ' - 8 " 24'-3" 22'-9" 25'-5" 23'-11" (N) SFD 2,055 S.F. (E) = 1,813 S.F. (N) = 242 S.F. (N) GARAGE 492 S.F. (E) = 412 S.F. (N) = 80 S.F. (N) PATIO 212 S.F. (N) PORCH 45 S.F. (E ) W A L K W A Y (E) F.H. (E) W.M. (E) G.M. (N) E.P. 16'-0" E L M O N T E A V E L E R O Y A V E 3' - 0 " AREA OF WORK GARAGE ADDITION = 80 S.F. 10 ' - 3 " 25'-0" PATIO POST SETBACK 5%5%5%5%5% 5%5%5% 5% 5%5% 5% 5% 5% 5% 5%5% 2%2%2% 2% 2% 2%2%2% 2% 2% 2%2%2%2% 4'4" X 3' LANDING (E) H.W. TANK TYPE Walking to the closest bus stop takes 7 min. 0.3 miles.NO R T H PROJECT SITE VICINITY MAP TITLE SHEET SITE PLAN PROJECT INFO T-1 X APN :5782-009-016 ZONING :R-1 (7,500) TYPE OF CONSTRUCTION :V-B (City of Arcadia) OCCUPANCY GROUP :R-3 FIRE SPRINKLERED :NO PROPERTY ADDRESS : 184 Le Roy Ave. Arcadia, CA 91007 PROPERTY OWNER : Robert S Hsu & Monica C Hsu PROJECT DIRECTORY 184 Le Roy Ave. Arcadia, CA 91007 Tel: - ALL WORK AND MATERIALS SHALL COMPLY WITH THE FOLLOWING: ·2022 CALIFORNIA BUILDING CODE (CBC) ·2022 CALIFORNIA FIRE CODE (CFC) ·2022 CALIFORNIA MECHANICAL CODE (CMC) ·2022 CALIFORNIA PLUMBING CODE (CPC) ·2022 CALIFORNIA ELECTRICAL CODE (CEC) ·2022 CALIFORNIA GREEN CODE (CGC) ·AND ALL APPLICABLE CODES, LOCAL, CURRENT OSHA LAWS, T-24 ENERGY CONSERVATION, LISTS OF STANDARDS. ADU ADDRESS : - LOT SIZE FLOOR AREA = 8,250 SQ. FT. (N) SFD 2,055 SQ. FT. = = 2,055 SQ. FT.TOTAL = F.A.R.=24.9 %=2055 / 8250 COVERED AREA =(N) SFD 2,055 SQ. FT.= LOT COVERAGE =34.0 %= PROJECT DATA APPLICABLE CODES PV SYSTEM:- 1 (E) 1,813 S.F. SFD TO BE RENOVATED; SCOPE OF WORK AREA CALCULATION WITH 4-BEDROOMS, 3-BATHROOMS, 1-LIVING ROOM, 1-KITCHEN 2804 / 8250 =(N) PORCH 45 SQ. FT.= (N) GARAGE 492 SQ. FT. SCALE: 1/8" = 1'-0" EXISTING SITE PLAN NORTH SCALE: 1/8" = 1'-0" PROPOSED SITE PLAN = 2,804 SQ. FT.TOTAL = A-0.2 DEMOLITION FLOOR PLAN 1 2 3 4 5 6 7 Revisions Date Project Name & Address : Sheet Content : AHJ Stamp Approval : Date Drawn By Issue Date By 1st 2nd 3rd Owner : Sheet Number : Sheet :Of : HOME ADDITION 184 Le Roy Ave. Arcadia, CA 91007 Robert S Hsu & Monica C Hsu 9.8.2024 Sarina Truong X Building Correction 9.8.2024 -- -- -- -- -- -- (N) PATIO 212 SQ. FT.= A-0.1 EXISTING FLOOR PLAN (E) GARAGE 412 S.F.,2 NEW ROOF, NEW PAINT, NEW WINDOWS AND DOORS; (N) ADDITION = 242 S.F., TOTAL (N) SFD = 2,055 S.F. (N) ADDITION = 80 S.F., TOTAL (N) GARAGE = 492 S.F. (N) PORCH = 45 S.F.; (N) PATIO = 212 S.F. T-1 TITLE SHEET; SITE PLAN; PROJECT INFORMATION A-1 PROPOSED FLOOR PLAN A-2.1 PROPOSED POWER PLAN SHEET INDEX ARCHITECTURAL A-3 PROPOSED EXTERIOR ELEVATIONS A-4 PROPOSED BUILDING SECTIONS GN-1 CALIFORNIA BUILDING CODE GN-2 CALIFORNIA BUILDING CODE TITLE 24 T-1 T-2 T-3 STRUCTURAL S101 S201 S301 S401 S501 TITLE 24 REPORTS TITLE 24 REPORTS TITLE 24 REPORTS GENERAL NOTES FOUNDATION PLAN ROOF FRAMING PLAN FOUNDATION DETAILS FRAMING DETAILS FLR GYP. BD. - GYPSUM BOARD FDN FTG - FOOTING - FOUNDATION - FLOOR WD.- WOOD TYP. SQ. SIM. - TYPICAL - SQUARE - SIMILAR EQ. F.F. FIN F.G. - FINISH, FINISHED - FINISH FLOOR - FINISH GRADE - EQUAL DET. CONC. - DETAIL - CONCRETE REQ.- REQUIRED NO. O.C. - NUMBER - PROPERTY LINE - ON CENTER A.F.F.- ABOVE FINISH FLOOR MAX MECH. MIN. - MECHANICAL - MAXIMUM - MINIMUM (E) - EXISTING S.F.- SQUARE FEET U.O.N.- UNLESS OTHERWISE NOTED N.T.S.- NOT TO SCALE - VERIFY IN FIELDV.I.F. W&D -WASH AND DRYER PL D.S.- DOWN SPOUT A.C.- AIR CONDITION G.M.- GAS METER F.H.- FIRE HYDRANT (N) - NEW E.P. - ELECTRICAL PANEL P.P.- POWER POLE W.M.- WATER METER ABBREVATIONS The ground immediately adjacent to the foundation shall be sloped away from the building at a slope of not less than one unit vertical in 20 units horizontal (5% slope) for a minimum distance of 10 feet measured perpendicular to the face of the wall. Impervious surfaces within 10 feet of the building foundation shall be sloped a minimum of 2 percent away from the building. Projects requiring CALGreen code compliance must recycle and/or salvage for reuse a minimum of 65% of the non-hazardous construction and demolition waste in accordance with the CALGreen Code Sections 4.408.1 and 5.408.1. Plumbing fixtures shall comply with water conservation flow rates: showerheads- 1.8 gpm, lavatory faucets- 1.2 gpm, kitchen faucets- 1.8 gpm, water closets- 1.28 gpf. GENERAL NOTES: 1. Do not scale drawings. Contractors shall verify all conditions and dimensions at job site. If any discrepancies are found, the designer shall be notified. 2. All information shown on the drawings relative to existing conditions is given as best possible, but without guarantee of accuracy. Where actual conditions conflict with the drawing, they shall be reported to the architect so that the proper revisions may be made. Modifications of details of construction shall not be made without written approval of the designer. A-5 DOOR & WINDOW SCHEDULE A-2.2 PROPOSED ROOF PLAN Sarina Tel : 626.598.9988 DESIGNER : Email: mangodesign5988@gmail.com APPLICANT : Mango Design Email: mangodesign5988@gmail.com Tel: 626.598.9988 STRUCTURAL ENGINEER : TITLE 24 CONSULTANT : Email: - Tel: 840.999.8547 7353 Ellena W Rancho Cucamonga, CA 91730 MGD Company NB Engineering, INC. Email: info@nbengineering.net Tel: 626.268.9321 19119 Colima Rd. Unit 111, Rowland Heights, CA 91748 S402 FOUNDATION DETAILS S502 FRAMING DETAILS S503 FRAMING DETAILS AC W.H. TANKLESS EP WH 44'-6" 43 ' - 0 " 78'-2" 27 ' - 0 " 9' - 1 0 " 13'-2"20'-6" 20'-0" 5' - 8 " 10 ' - 4 " 4: 1 2 S L O P E U . N . O . TO M A T C H ( E ) S F D RIDGE EXTERIOR WALL BELOW (N) SFD (N ) 1 8 " EA V E , U. N . O . ROOF LINE, TYP. 14*6 EAVE VENT, TYP. RIDGE RIDGE HI P HIPHI P HIP HI P VA L L E Y VA L L E Y HI P H I P SCALE: 1/4" = 1'-0" PROPOSED ROOF PLAN 1 2 3 4 5 6 7 Revisions Date Project Name & Address : Sheet Content : AHJ Stamp Approval : Date Drawn By Issue Date By 1st 2nd 3rd Owner : Sheet Number : Sheet :Of : HOME ADDITION 184 Le Roy Ave. Arcadia, CA 91007 Robert S Hsu & Monica C Hsu 9.8.2024 Sarina Truong X Building Correction 9.8.2024 -- -- -- -- -- -- PROPOSED ROOF PLAN A-2.2 X ATTIC VENTILATION CALCULATION: TOTAL ATTIC AREA: 2,055 SQ. FT. VENTILATION AREA REQUIRED: 2055 / 150 = 13.7 SQ. FT. = 1972.8 SQ. IN. VENTILATION AREA PROVIDED: 49 * 41 = 2009 SQ. IN. > 1972.8 SQ. IN. ROOF NOTE: ATTIC VENTILATION OPENINGS SHALL BE COVERED WITH CORROSION-RESISTANT METAL MESH WITH 1/16" MINIMUM TO 4 " MAXIMUM OPENINGS. SECTION R8061 ROOFING MATERIAL: MANUFACTURER: GAF PRODUCT: TIMEBERLINE HDZ SHINGLES ICC REPORT: ESR-1475 12 4 TO MATCH (E) SFD 9' - 0 " 5' - 0 " 15 ' - 1 " F.G. TOP PLATE LINE RIDGE LINE F.F.L. 12 - 3 / 4 " 1'-6" 10 ' - 0 - 3 / 4 " 5' - 0 " 15 ' - 1 " TOP PLATE LINE RIDGE LINE GARAGE F.F.L. / F.G. 1 2 378 4' - 0 " 2' - 8 " 5'-0" 11 (N) CONC. SLAB 1'-6" 12 4 TO MATCH (E) SFD 12 3 478 4' - 0 " 2' - 8 " 6'-0" 4' - 0 " 2' - 8 " 8'-0" 3'-0" 6' - 8 " 56 11 9' - 0 " 5' - 0 " 15 ' - 1 " F.G. TOP PLATE LINE RIDGE LINE F.F.L. 12 " 3/ 4 " (N ) G Y P C R E T E (E) RAISED FLOOR 1'-6"1'-6" 10 ' - 0 - 3 / 4 " 5' - 0 " 15 ' - 1 " TOP PLATE LINE RIDGE LINE GARAGE F.F.L. / F.G. 12 4 TO MATCH (E) SFD 1 3 7 8 4' - 0 " 2' - 8 " 5'-0" 4' - 0 " 2' - 8 " 5'-0" 3' - 0 " 3' - 8 " 4'-0" 4' - 0 " 2' - 8 " 5'-0" 1 2 34 9' - 0 " 5' - 0 " 15 ' - 1 " F.G. TOP PLATE LINE RIDGE LINE F.F.L. 12 " 3/ 4 " (N ) G Y P C R E T E (E) RAISED FLOOR 1'-6"1'-6" 12 4 TO MATCH (E) SFD 12 34678 4' - 0 " 2' - 8 " 5'-0" 1' - 4 " 5' - 4 " 3'-0"4' - 0 " 2' - 8 " 3'-0" 1' - 4 " 5' - 4 " 3'-0" 3'-0" 6' - 8 " 1 7 89 10 9' - 0 " 5' - 0 " 15 ' - 1 " F.G. TOP PLATE LINE RIDGE LINE F.F.L. 12 " 3/ 4 " (N ) G Y P C R E T E (E) RAISED FLOOR 9' - 0 " 5' - 0 " 15 ' - 1 " F.G. TOP PLATE LINE RIDGE LINE F.F.L. 12 - 3 / 4 " (N) CONC. SLAB 8' - 0 " (E ) T O P P L A T E H T . 9‘ - 0 “ (N ) T O P P L A T E H T . (E) PIER FOOTING (E) FLOOR JOIST (E) SILL PLATE (E) STUD WALL (E) DBL. TOP PLATE (N) MTL. STRAP ON BOTH SIDES (N) STUD WALL EXTENSION (N) RAFTER (N) CEILING JOIST (N) DBL. TOP PLATE (E) STUD WALL 2" MIN.(N) WINDOW FRAME GLAZING (N) WINDOW FRAME (E) HEADER (N) WINDOW TRIM (E) STUD WALL INTERIOR EXTERIOR PROPOSED EXTERIOR ELEVATIONS A-3 X 6 7 EXTERIOR LIGHTING FIXTURE TO MATCH (E) SFD STYLE, MATERIAL 8 ATTIC VENT FASCIA BOARD AT EAVE END MATCH EXISTING MAIN HOUSE AND COLOR KEY NOTES: 1 COMPOSITION (CLASS-A) ROOF SHINGLES COLOR: BROWN 2 EXTERIOR WALL STUCCO, COLOR: CREAM 3 VINYL WINDOW WITH GRILLES 4 EXTERIOR WOOD DOOR MATERIAL AND COLOR 5 VINYL PLAIN PATIO DOOR AND COLOR TO MATCH (E) SFD STYLE, MATERIAL TO MATCH (E) SFD STYLE, WOOD TO MATCH (E) SFD STYLE, MATERIAL WITH 2 LAYERS, COLOR MATCH EXISTING, TO MATCH (E) SFD TEXTURE AND COLOR SLIDING WINDOW ICC# ESAC 438 INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. FRAME COLOR: WHITE COLOR: DARK BROWN FRAME COLOR: WHITE COLOR: WHITE IRON COLOR: DARK BROWN PROPOSED SOUTH ELEVATION PROPOSED EAST ELEVATION PROPOSED WEST ELEVATION 1 2 3 4 5 6 7 Revisions Date Project Name & Address : Sheet Content : AHJ Stamp Approval : Date Drawn By Issue Date By 1st 2nd 3rd Owner : Sheet Number : Sheet :Of : HOME ADDITION 184 Le Roy Ave. Arcadia, CA 91007 Robert S Hsu & Monica C Hsu 9.8.2024 Sarina Truong X Building Correction 9.8.2024 -- -- -- -- -- -- SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" PROPOSED NORTHELEVATION SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" 2 1 4 3 BUT ALL WINDOW CHANGE NO GRID, 2SCALE: N.T.S.RECESSED WINDOW DETAIL 1SCALE: N.T.S.WALL EXTENSION DETAIL 1'-6" 12 4 TO MATCH (E) SFD 9' - 0 " 5' - 0 " 15 ' - 1 " F.G. TOP PLATE LINE RIDGE LINE F.F.L. 12 " 3/ 4 " (N ) G Y P C R E T E (E) RAISED FLOOR 1'-6" 10 ' - 0 - 3 / 4 " 5' - 0 " 15 ' - 1 " TOP PLATE LINE RIDGE LINE GARAGE F.F.L. / F.G. RIDGE BOARD RAFTER CEILING JOIST RADIANT BARRIER RADIANT BARRIER R-38 INSULATION WINDOW, TYP. R-19 INSULATION EXTERIOR WALL, 3-PLY STUCCO, R-19 INSULATION GARAGE BED-2 FLOOR JOIST 18 " CL R . R-19 INSULATION R-15 INSULATION FOUNDATION (E) FLOOR JOIST & FOUNATION(N) FLOOR JOIST & FOUNATION BED-3 BED-4HALLWAY INSTALL MIN. 1/2" GYP. BD THRU ATTIC TO ROOF SHEATHING TO THE GARAGE SIDE R-15 INSULATION R-15 INSULATION R-15 INSULATION ELECTRICAL OUTLET BOX FOR ELECTRICAL RECEPTACLES, SWITCHES, CONTROLS AND DOORBELLS 2x WALL STUD F.F.L. 48 " M A X . 15 " M I N . 12 4 TO MATCH (E) SFD 9' - 0 " 5' - 0 " 15 ' - 1 " F.G. TOP PLATE LINE RIDGE LINE F.F.L. 12 - 3 / 4 " 1'-6" (N) CONC. SLAB EXTERIOR WALL, 3-PLY STUCCO, R-19 INSULATION FLOOR JOIST RAFTER RADIANT BARRIER RIDGE BOARD CEILING JOIST R-38 INSULATION WINDOW, TYP. BED-3KIT. 3/ 4 " (N ) G Y P C R E T E 18 " CL R . R-19 INSULATION R-15 INSULATION FOUNDATION (E) FLOOR JOIST & FOUNATION (N) FLOOR JOIST & FOUNATION 1 2 3 4 5 6 7 Revisions Date Project Name & Address : Sheet Content : AHJ Stamp Approval : Date Drawn By Issue Date By 1st 2nd 3rd Owner : Sheet Number : Sheet :Of : HOME ADDITION 184 Le Roy Ave. Arcadia, CA 91007 Robert S Hsu & Monica C Hsu 9.8.2024 Sarina Truong X Building Correction 9.8.2024 -- -- -- -- -- -- PROPOSED BUILDING SECTIONS A-4 X SCALE: 1/4" = 1'-0" SECTION A-AA 18SCALE: N.T.S.DETAIL 16SCALE: N.T.S.DETAIL 15SCALE: N.T.S.OUTLET BOX DETAIL 14SCALE: N.T.S.13SCALE: N.T.S.1-HOUR FIRE RATED WALL & EAVE SCALE: 1/4" = 1'-0" SECTION B-BB DETAIL