Loading...
HomeMy WebLinkAboutApproved PlansFH WM EP WH GM AC 21 ' - 2 " 25'-5" 4' - 7 " 24'-3" PROPERTY LINE: 125' (E) DRIVEWAY (E ) S I D E W A L K (E) LANDSCAPE PROPERTY LINE: 105' P R O P E R T Y L I N E : 6 5 . 9 ' P R O P E R T Y L I N E : 4 5 . 9 ' P R O P E R T Y L I N E : 3 1 . 4 2 ' (E) SIDEWALK (E) LANDSCAPE (E ) W A L K W A Y (E) A.C. (E) W.H. (E) E.P. (E) W.M. (E) G.M. (E) GARAGE 412 S.F.(E) SFD 1,813 S.F. (E) F.H. FH WM GM AC W.H. TANKLESS EP WH (E) 6'H CMU BL0CK WALL PROPERTY LINE: 125' 4:12 SLOPE TO MATCH (E) SFD EXTERIOR WALL LINE ROOF LINE (E) DRIVEWAY (E ) S I D E W A L K (E) A.C. (N) W.H. TANKLESS (E) LANDSCAPE AREA OF WORK SFD ADDITION = 242 S.F. 1' - 6 " EA V E U. N . O . PROPERTY LINE: 105' P R O P E R T Y L I N E : 6 5 . 9 0 ' (E ) 6 ' H W O O D F E N C E 7'6" x 6' LANDING (N) CONC. WALKWAY P R O P E R T Y L I N E : 4 5 . 9 0 ' P R O P E R T Y L I N E : 3 1 . 4 2 ' (E) SIDEWALK (E) LANDSCAPE (E) LANDSCAPE 4' - 7 " 3' - 1 " 21 ' - 2 " 19 ' - 8 " 24'-3" 22'-9" 25'-5" 23'-11" (N) SFD 2,055 S.F. (E) = 1,813 S.F. (N) = 242 S.F. (N) GARAGE 492 S.F. (E) = 412 S.F. (N) = 80 S.F. (N) PATIO 212 S.F. (N) PORCH 45 S.F. (E ) W A L K W A Y (E) F.H. (E) W.M. (E) G.M. (N) E.P. 16'-0" E L M O N T E A V E L E R O Y A V E 3' - 0 " AREA OF WORK GARAGE ADDITION = 80 S.F. 10 ' - 3 " 25'-0" PATIO POST SETBACK 5%5%5%5%5% 5%5%5% 5% 5%5% 5% 5% 5% 5% 5%5% 2%2%2% 2% 2% 2%2%2% 2% 2% 2%2%2%2% 4'4" X 3' LANDING (E) H.W. TANK TYPE Walking to the closest bus stop takes 7 min. 0.3 miles.NO R T H PROJECT SITE VICINITY MAP TITLE SHEET SITE PLAN PROJECT INFO T-1 X APN :5782-009-016 ZONING :R-1 (7,500) TYPE OF CONSTRUCTION :V-B (City of Arcadia) OCCUPANCY GROUP :R-3 FIRE SPRINKLERED :NO PROPERTY ADDRESS :184 Le Roy Ave. Arcadia, CA 91007 PROPERTY OWNER :Robert S Hsu & Monica C Hsu PROJECT DIRECTORY 184 Le Roy Ave. Arcadia, CA 91007 Tel: - ALL WORK AND MATERIALS SHALL COMPLY WITH THE FOLLOWING: ·2022 CALIFORNIA BUILDING CODE (CBC) ·2022 CALIFORNIA FIRE CODE (CFC) ·2022 CALIFORNIA MECHANICAL CODE (CMC) ·2022 CALIFORNIA PLUMBING CODE (CPC) ·2022 CALIFORNIA ELECTRICAL CODE (CEC) ·2022 CALIFORNIA GREEN CODE (CGC) ·AND ALL APPLICABLE CODES, LOCAL, CURRENT OSHA LAWS, T-24 ENERGY CONSERVATION, LISTS OF STANDARDS. ADU ADDRESS :- LOT SIZE FLOOR AREA = 8,250 SQ. FT. (N) SFD 2,055 SQ. FT. = = 2,055 SQ. FT.TOTAL = F.A.R.=24.9 %=2055 / 8250 COVERED AREA =(N) SFD 2,055 SQ. FT.= LOT COVERAGE =34.0 %= PROJECT DATA APPLICABLE CODES PV SYSTEM:- 1 (E) 1,813 S.F. SFD TO BE RENOVATED; SCOPE OF WORK AREA CALCULATION WITH 4-BEDROOMS, 3-BATHROOMS, 1-LIVING ROOM, 1-KITCHEN 2804 / 8250 =(N) PORCH 45 SQ. FT.= (N) GARAGE 492 SQ. FT. SCALE: 1/8" = 1'-0" EXISTING SITE PLAN NORTH SCALE: 1/8" = 1'-0" PROPOSED SITE PLAN = 2,804 SQ. FT.TOTAL = A-0.2 DEMOLITION FLOOR PLAN 1 2 3 4 5 6 7 Revisions Date Project Name & Address : Sheet Content : AHJ Stamp Approval : Date Drawn By Issue Date By 1st 2nd 3rd Owner : Sheet Number : Sheet :Of : HOME ADDITION 184 Le Roy Ave. Arcadia, CA 91007 Robert S Hsu & Monica C Hsu 9.8.2024 Sarina Truong X Building Correction 9.8.2024 -- -- -- -- -- -- (N) PATIO 212 SQ. FT.= A-0.1 EXISTING FLOOR PLAN (E) GARAGE 412 S.F.,2 NEW ROOF, NEW PAINT, NEW WINDOWS AND DOORS; (N) ADDITION = 242 S.F., TOTAL (N) SFD = 2,055 S.F. (N) ADDITION = 80 S.F., TOTAL (N) GARAGE = 492 S.F. (N) PORCH = 45 S.F.; (N) PATIO = 212 S.F. T-1 TITLE SHEET; SITE PLAN; PROJECT INFORMATION A-1 PROPOSED FLOOR PLAN A-2.1 PROPOSED POWER PLAN SHEET INDEX ARCHITECTURAL A-3 PROPOSED EXTERIOR ELEVATIONS A-4 PROPOSED BUILDING SECTIONS GN-1 CALIFORNIA BUILDING CODE GN-2 CALIFORNIA BUILDING CODE TITLE 24 T-1 T-2 T-3 STRUCTURAL S101 S201 S301 S401 S501 TITLE 24 REPORTS TITLE 24 REPORTS TITLE 24 REPORTS GENERAL NOTES FOUNDATION PLAN ROOF FRAMING PLAN FOUNDATION DETAILS FRAMING DETAILS FLR GYP. BD.- GYPSUM BOARD FDN FTG - FOOTING - FOUNDATION - FLOOR WD.- WOOD TYP. SQ. SIM. - TYPICAL - SQUARE - SIMILAR EQ. F.F. FIN F.G. - FINISH, FINISHED - FINISH FLOOR - FINISH GRADE - EQUAL DET. CONC. - DETAIL - CONCRETE REQ.- REQUIRED NO. O.C. - NUMBER - PROPERTY LINE - ON CENTER A.F.F.- ABOVE FINISH FLOOR MAX MECH. MIN. - MECHANICAL - MAXIMUM - MINIMUM (E)- EXISTING S.F.- SQUARE FEET U.O.N.- UNLESS OTHERWISE NOTED N.T.S.- NOT TO SCALE - VERIFY IN FIELDV.I.F. W&D -WASH AND DRYER PL D.S.- DOWN SPOUT A.C.- AIR CONDITION G.M.- GAS METER F.H.- FIRE HYDRANT (N)- NEW E.P.- ELECTRICAL PANEL P.P.- POWER POLE W.M.- WATER METER ABBREVATIONS The ground immediately adjacent to the foundation shall be sloped away from the building at a slope of not less than one unit vertical in 20 units horizontal (5% slope) for a minimum distance of 10 feet measured perpendicular to the face of the wall. Impervious surfaces within 10 feet of the building foundation shall be sloped a minimum of 2 percent away from the building. Projects requiring CALGreen code compliance must recycle and/or salvage for reuse a minimum of 65% of the non-hazardous construction and demolition waste in accordance with the CALGreen Code Sections 4.408.1 and 5.408.1. Plumbing fixtures shall comply with water conservation flow rates: showerheads- 1.8 gpm, lavatory faucets- 1.2 gpm, kitchen faucets- 1.8 gpm, water closets- 1.28 gpf. GENERAL NOTES: 1.Do not scale drawings. Contractors shall verify all conditions and dimensions at job site. If any discrepancies are found, the designer shall be notified. 2.All information shown on the drawings relative to existing conditions is given as best possible, but without guarantee of accuracy. Where actual conditions conflict with the drawing, they shall be reported to the architect so that the proper revisions may be made. Modifications of details of construction shall not be made without written approval of the designer. A-5 DOOR & WINDOW SCHEDULE A-2.2 PROPOSED ROOF PLAN Sarina Tel : 626.598.9988 DESIGNER : Email: mangodesign5988@gmail.com APPLICANT :Mango Design Email: mangodesign5988@gmail.com Tel: 626.598.9988 STRUCTURAL ENGINEER : TITLE 24 CONSULTANT : Email: - Tel: 840.999.8547 7353 Ellena W Rancho Cucamonga, CA 91730 MGD Company NB Engineering, INC. Email: info@nbengineering.net Tel: 626.268.9321 19119 Colima Rd. Unit 111, Rowland Heights, CA 91748 S402 FOUNDATION DETAILS S502 FRAMING DETAILS S503 FRAMING DETAILS EP WH AC 20'-0"6'-2"18'-4"12'-2"8'-0" 8'-0" 5' - 0 " 12 ' - 6 " 13 ' - 4 " 7' - 6 " 40 ' - 0 " 75'-2" 19 ' - 1 " 2' - 1 " 13 ' - 4 " 11'-6"6'-8"3'-0"12'-6" 19'-0" 5'-10"6'-3"6'-11" 20'-6" 75'-2" 40 ' - 0 " 6"3'-0"4'-6" 20 ' - 1 " 3' - 8 " 16 ' - 3 " 35'-8" 7' - 6 " 32 ' - 6 " 67'-2" (E) BATH-1 (E) STO. CLO. (E) GARAGE (E) BATH-2 (E) BED-1(E) BED-2 (E) LIV. (E) DIN.(E) KIT. (E) FAM. SCALE: 1/4" = 1'-0" EXISTING FLOOR PLAN EXISTING FLOOR PLAN A-0.1 X 1 2 3 4 5 6 7 Revisions Date Project Name & Address : Sheet Content : AHJ Stamp Approval : Date Drawn By Issue Date By 1st 2nd 3rd Owner : Sheet Number : Sheet :Of : HOME ADDITION 184 Le Roy Ave. Arcadia, CA 91007 Robert S Hsu & Monica C Hsu 9.8.2024 Sarina Truong X Building Correction 9.8.2024 -- -- -- -- -- -- NORTHNORTH WALL LEGEND EXISTING WALL TO REMAIN (E) WALL TO BE DEMO (N) WOOD STUD WALL (N) PLUMBING WALL, 2x6 STUD (E) WALL OPN'G TO BE IN-FILLED (E) BATH-1 (E) STO. CLO. (E) GARAGE (E) BATH-2 (E) BED-1(E) BED-2 (E) LIV. (E) DIN. (E) KIT. (E) FAM. SCALE: 1/4" = 1'-0" DEMOLISH FLOOR PLAN NORTH SCALE: 1/4" = 1'-0" DEMOLISH FLOOR PLAN DEMOLITION FLOOR PLAN A-0.2 X NORTH 1 2 3 4 5 6 7 Revisions Date Project Name & Address : Sheet Content : AHJ Stamp Approval : Date Drawn By Issue Date By 1st 2nd 3rd Owner : Sheet Number : Sheet :Of : HOME ADDITION 184 Le Roy Ave. Arcadia, CA 91007 Robert S Hsu & Monica C Hsu 9.8.2024 Sarina Truong X Building Correction 9.8.2024 -- -- -- -- -- -- AC W.H. TANKLESS AC DW EP RE F WH WALL LEGEND EXISTING WALL TO REMAIN (E) WALL TO BE DEMO (N) WOOD STUD WALL (N) PLUMBING WALL, 2x6 STUD (E) WALL OPN'G TO BE IN-FILLED 7' - 6 " CO N C . P A D 6'-0" CONC. PAD 4 A-3 3 A-3 2 A-3 1 A-3 1 GARAGE LIV. BATH-1 41'-6"13'-2"20'-6" 14'-3"3'-0"2'-4"3'-0"9'-2"5'-0"4'-9"4"3'-0"17'-2" 34 ' - 4 " 24 ' - 0 " 5' - 8 " 40 ' - 0 " 10 ' - 4 " 20 ' - 1 " 2' - 1 1 " 5' - 0 " 2' - 5 " 75'-2" 8'-0"67'-2" 1'-4"5'-0"8'-6"4'-0"5'-4"5'-0"4'-11"5'-0"5'-6" 40 ' - 0 " 7' - 6 " 32 ' - 6 " 12 " 6' - 0 " 5" 3' - 6 " 8' - 0 " 8' - 8 " 6' - 0 " 6' - 5 " C L R . 13 ' - 1 1 " 17 ' - 3 " C L R . 21 ' - 5 " 8'-0" 24'-4"8'-2"12'-10"20'-0" 9'-2" 5' - 0 " 23 ' - 0 " 20 ' - 3 " CL R . 11 ' - 7 " 12'-8" 13'-6"8'-5" 9' - 1 0 " 5'-0"12'-5" 2' - 0 " 1' - 8 " 1'-8" 4'-0"3' - 1 1 " 5' - 4 " 16'-0"6'-7" 75'-2" (N) A.C. (N) A.C. (N) E.P. BATH-2 BATH-3 BED-1 BED-2 BED-3 BED-4 KIT. PATIO PORCH 1 2 3 4 5 6 789 11 10 2 3 4 5 6 7 8 9 10 11 3' - 1 1 " CLO.CLO. CLO. CLO. 5'-10"35'-8" 7' - 6 " 2' - 6 " A A-4 B A-4 B A-4 A A-4 A MAX. 1/4" INCH VERTICAL RISE IS ALLOWED, AND A MAX. 1/2" WHEN A 1:12 BEVELED THRESHOLD IS PROVIDED. 8 9 10 11 1214 16 17 T T T E E E E E (N) W.H. TANKLESS 2 4 5 6 2 4 5 6 2 4 5 6 1 1 1 3 3 3 7 17 (N) 1-HOUR FIRE RATED EXTERIOR WALL 13 A-4 3' - 0 " LA N D I N G (N) H.W. TANK TYPE 12 T TEMPERED GLASS TYP. SAFETY GLAZING SHALL BE IN CONFORMANCE WITH THE APPLICABLE L.A.C.R.C. ALL EXTERIOR DOORS SHALL BE 1-3/8"(MIN) WITH TEMPERED GLASS U.N.O. EMERGENCY EGRESS WINDOW PROVIDE THE FOLLOWING.5.7 SQ. FT. OF CLEAR OPENABLE AREA (5.0 AT GRADE) E NET OPENING HEIGHT SHALL BE 24" MIN.NET OPENING WIDTH SHALL BE 20" MIN.FINISHED SILL HEIGHT OF 44" MAX. ABOVE FLOOR. WATER CLOSET. PROVIDE 30" MIN. CLR. WIDTH AND 24" CLR SPACE IN FRONT.4" WASTE LINE SHALL BE USED FOR 1 SERVING 4 OR MORE WATER CLOSETS(CPI 703.2) HOT-MOPPED SHOWER PAN WITH MUDSET CERAMIC TILE/NATURAL STONE FLOOR. FULL HEIGHT CERAMIC 2 TILE/NATURAL STONE WALLS WITH 84" HEIGHT SHOWER HEAD. PROVIDE TEMPERED GLASS ENCLOSURE. MIRROR (TYP.) 3 SHOWER ENCLOSURE WITH APPROVED SHATTER RESISTANT MATERIALS AND PROVIDE 6'-0" HT. NON-ABSORBENT 4 WALLS ADJACENT TO SHOWER. WINDOWS WITHIN 5' OF DRAIN OF SHOWER OR BATHROOM FLOOR TO BE SHATTER RESISTANT & LABELED SAFETY GLAZING (TYP.) ALL BATHROOM FLOORING SHALL BE LAID OVER 15 LB.FELT (TYP.) 5 NET AREA OF SHOWER RECEPTOR SHALL BE NOT LESS THAN 1,024 S.F IN. OF FLOOR AREA AND ENCOMPASS 30 6 INCH (762 MM) DIAMETER CIRCLE. (TYP.) TANKLESS WATER HEATER7 33" CLR. WASHER SPACE. PROVIDE RECESSED WATER /WASTE LINE HOOK UP AND GALV. SHUT. METAL SMUTTY8 PAN.PROVIDE A PROTECTIVE BARRIER IN FRONT OF WASHER/DRYER IN THE GARAGE FOR THE PHYSICAL PROTECTION(CMC 308.1.1.) GAS DRYER.9 REFRIGERATOR SPACE WITH COLD WATER CONNECTION. 10 RANGE HOOD VENTING DIRECTLY TO THE BUILDING EXTERIOR AND SHALL PROVIDE MIN. 100 CFM WITH AT LEAST 11 ONE FAN SPEED SETTING AT MAX. SOUND RATING OF 3 SONES. PROVIDE 30" CLEARANCE ABOVE RANGE TO UNPROTECTED COMBUSTIBLE MATERIAL OR 24" TO METAL VENTILATION HOOD, GAS STOVE. GARBAGE DISPOSAL 12 OVEN OR MICROWAVE SPACES 13 CABINET ABOVE (TYP.) 14 HOSE BIBB WITH PERMANENT NOON-REMOVABLE ANTI-SYPHON VALVE. 15 30" * 22" ATTIC ACCESS (TYP.) 16 KEY NOTES CENTRAL A/C17 NOTES: 1.ALL INTERIOR MATERIALS USED SHALL MEET THE MIN. REQ. FOR "FLAME SPREAD INDEX" AND "SMOKE DEVELOPED INDEX" AS REQUIRED BY SECTION R302.9.1 & R302.9.2 CRC PROPOSED FLOOR PLAN A-1 X NORTH SCALE: 1/4" = 1'-0" PROPOSED FLOOR PLAN 1 2 3 4 5 6 7 Revisions Date Project Name & Address : Sheet Content : AHJ Stamp Approval : Date Drawn By Issue Date By 1st 2nd 3rd Owner : Sheet Number : Sheet :Of : HOME ADDITION 184 Le Roy Ave. Arcadia, CA 91007 Robert S Hsu & Monica C Hsu 9.8.2024 Sarina Truong X Building Correction 9.8.2024 -- -- -- -- -- -- AC W.H. TANKLESS AC DW EP RE F WH GARAGE LIV. BATH-1 F 1'-8" SS SS F S S SS S S S S S S S S S S S S S S SS S S SS SF (N) A.C. (E) A.C. (N) W.H. BATH-2 BATH-3 BED-1 BED-2 BED-3 BED-4 KIT. PATIO PORCH CLO.CLO. CLO. CLO. TANKLESS S S S SM SM SM SM S&C S&C (N) 200 AMP E.P. W/ 225 BUSBAR (E) H.W. TANK TYPE ELECTRICAL DUPLEX OUTLET W/ TAMPER RESISTANT DUPLEX OUTLET W/ ARC FAULT CIRCUIT INTERRUPTION & SHALL BE TAMPER RESISTANT DUPLEX OUTLET W/ GROUND FAULT CIRCUIT INTERRUPTION & SHALL BE TAMPER RESISTANT WALL MOUNT LIGHTING FIXTURE (HIGH EFFICACY) RECESSED LIGHTING FIXTURE (HIGH EFFICACY) PENDANT LIGHTING FIXTURE (HIGH EFFICACY) SMOKE DETECTOR TO BE HARD WIRED & INTERCONNECTED WITH BATTERY BACK UP SYMBOL LEGEND DOOR BELL BATHROOM EXHAUST FAN TO BE ENERGY STAR & F PROVIDE MIN. 100 CFM AIR EXCHANGE RATE, W/ HUMIDISTAT CONTROL TO EXHAUST MOISTURE TO THE EXTERIOR OF THE BUILDING. EXHAUST OUTLET MUST BE MINIMUM 3'-0" FROM ANY OPENINGS INTO BUILDING AND 3'-0" FROM THE PROPERTY LINE. SINGLE POLE SWITCH LIGHTING SWITCH W/ DIMMING FUNCTION LIGHTING SWITCH W/ OCCUPANCY SENSOR LIGHTING SWITCH W/ VACANCY SENSOR POWER SWITCH W/ HUMIDISTAT CONTROL SM S&C B S S S S S NOTE: ALL OUTLETS TO BE AFCI PROTECTED EXCEPT WHENEVER REQ'D TO BE GFCI PROTECTED.1. 2.PROVIDE DEDICATED 20 AMP CIRCUITS TO THE BATHROOMS AND LAUNDRY AREAS. 3.PROVIDE AT LEAST TWO 20 AMP SMALL APPLIANCE SMOKE AND CARBON MONODIXE COMBO DETECTOR TO BE HARD WIRED & INTERCONNECTED WITH BATTERY BACK UP 15 A-4 15 A-4 15 A-4 15 A-4 WALL LEGEND EXISTING WALL TO REMAIN (E) WALL TO BE DEMO (N) WOOD STUD WALL (N) PLUMBING WALL, 2x6 STUD (E) WALL OPN'G TO BE IN-FILLED (N) 1-HOUR FIRE RATED EXTERIOR WALL 13 A-4 NORTH SCALE: 1/4" = 1'-0" 1 2 3 4 5 6 7 Revisions Date Project Name & Address : Sheet Content : AHJ Stamp Approval : Date Drawn By Issue Date By 1st 2nd 3rd Owner : Sheet Number : Sheet :Of : HOME ADDITION 184 Le Roy Ave. Arcadia, CA 91007 Robert S Hsu & Monica C Hsu 9.8.2024 Sarina Truong X Building Correction 9.8.2024 -- -- -- -- -- -- PROPOSED POWER PLAN A-2.1 X PROPOSED POWER PLAN ELECTRICAL NOTES: 1.All installed luminaires shall be high-efficacy in accordance with ES TABLE 150.0-A a.Luminaries must have a label certified for airtight construction b.Light sources that are not marked “JA8-2016/2019/2022-E” shall not be installed in enclosed luminaires. ES 150.0(k) 2.Lighting fixtures that are attached to a building are required to be high efficacy be manually on/off switch controlled, and have both motion sensor and photocell control. 3.There will be a minimum of 2 small appliance branch circuits within the locations specified in Article 210.52(B), i.e., kitchen and dining areas. 4.Bathroom circuiting shall be either: a.A 20-ampere circuit dedicated to each bathroom, or b.At least one 20 ampere circuit supplying only bathroom receptacle outlets. 5.A dedicated 240 volt branch circuit wiring shall be installed within 3 feet from the cooktop and accessible to the cooktop with no obstructions. The branch circuit conductors shall be rated at 50 amps minimum. The blank cover shall be identified as "240V ready." All electrical components shall be installed in accordance with the California Electrical Code. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a future electric cooktop installation. The reserved space shall be permanently marked as "For Future 240V use." 6.A dedicated 240 volt branch circuit wiring shall be installed within 3 feet from the clothes dryer location and accessible to the clothes dryer location with no obstructions. The branch circuit conductors shall be rated at 30 amps minimum. The blank cover shall be identified as "240V ready." All electrical components shall be installed in accordance with the California Electrical Code. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a future electric clothes dryer installation. The reserved space shall be permanently marked as "For Future 240V use." 7.Title-24 Energy Requirements: add these notes on plan •A minimum of 50% of the luminaries in a kitchen must be fluorescent or high efficacy. •Bathrooms, Garages, laundry or utility rooms, and CLOSET must have fluorescent or high efficacy lighting, AND at least one luminaire in each of these spaces must be controlled by a vacancy sensor. •Bedrooms, living rooms, family rooms, kitchen and other rooms used for living and sleeping must have fluorescent or high efficacy lighting, or an occupant sensor, AND dimmers must be installed. •Exterior lighting must be fluorescent or high efficacy, or an occupant senor with an integral photo control may be installed. 8.A minimum of four branch circuits shall be identified and have their source of supply collocated at a single panelboard suitable to be supplied by the ESS. At least one circuit shall supply the refrigerator, one lighting circuit shall be located near the primary egress and at least one circuit shall supply a sleeping room receptacle outlet. 9.Recessed can light fixtures shall be IC listed, air-tight labeled, and not be equipped with a standard medium base screw shell lamp holder. 10.SFD outdoor lighting fixtures that are attached to a building are required to be high efficacy, be manually on/ off switch controlled, and have both motion sensor and photocell control. 11.Garage shall have automatic garage door opener with battery back-up. [Brand: LiftMaster |Listing: UL325] ELECTRIC COOKTOPS/CLOTHES DRYERS/HEATERS READY. Systems using gas or propane to serve individual dwelling for each of the following items shall include the following(ES150.0(t)(u)(v): a.A dedicated 240 volt branch circuit wiring shall be installed within 3 feet from the cooktop/clothes dryer/heater and be accessible with no obstructions. The branch circuit conductors shall be rated at (50 amps for cooktops, 30 amps for dryers, 30 amps for heaters) minimum. The blank cover shall be identified as "240V ready." All electrical components shall be installed in accordance with the California Electrical Code. b.The main electrical service panel shall have reserved spaces to allow for the installation of double pole circuit breakers for a future electric cooktop/clothes dryer/heater installation. The reserved spaces shall be permanently marked as "For Future 240V use." AC W.H. TANKLESS EP WH 44'-6" 43 ' - 0 " 78'-2" 27 ' - 0 " 9' - 1 0 " 13'-2"20'-6" 20'-0" 5' - 8 " 10 ' - 4 " 4: 1 2 S L O P E U . N . O . TO M A T C H ( E ) S F D RIDGE EXTERIOR WALL BELOW (N) SFD (N ) 1 8 " EA V E , U. N . O . ROOF LINE, TYP. 14*6 EAVE VENT, TYP. RIDGE RIDGE HI P HIPHI P HIP HI P VA L L E Y VA L L E Y HI P H I P SCALE: 1/4" = 1'-0" PROPOSED ROOF PLAN 1 2 3 4 5 6 7 Revisions Date Project Name & Address : Sheet Content : AHJ Stamp Approval : Date Drawn By Issue Date By 1st 2nd 3rd Owner : Sheet Number : Sheet :Of : HOME ADDITION 184 Le Roy Ave. Arcadia, CA 91007 Robert S Hsu & Monica C Hsu 9.8.2024 Sarina Truong X Building Correction 9.8.2024 -- -- -- -- -- -- PROPOSED ROOF PLAN A-2.2 X ATTIC VENTILATION CALCULATION: TOTAL ATTIC AREA: 2,055 SQ. FT. VENTILATION AREA REQUIRED: 2055 / 150 = 13.7 SQ. FT. = 1972.8 SQ. IN. VENTILATION AREA PROVIDED: 49 * 41 = 2009 SQ. IN. > 1972.8 SQ. IN. ROOF NOTE: ATTIC VENTILATION OPENINGS SHALL BE COVERED WITH CORROSION-RESISTANT METAL MESH WITH 1/16" MINIMUM TO 4 " MAXIMUM OPENINGS. SECTION R8061 ROOFING MATERIAL: MANUFACTURER: GAF PRODUCT: TIMEBERLINE HDZ SHINGLES ICC REPORT: ESR-1475 12 4 TO MATCH (E) SFD 9' - 0 " 5' - 0 " 15 ' - 1 " F.G. TOP PLATE LINE RIDGE LINE F.F.L. 12 - 3 / 4 " 1'-6" 10 ' - 0 - 3 / 4 " 5' - 0 " 15 ' - 1 " TOP PLATE LINE RIDGE LINE GARAGE F.F.L. / F.G. 1 2 378 4' - 0 " 2' - 8 " 5'-0" 11 (N) CONC. SLAB 1'-6" 12 4 TO MATCH (E) SFD 12 3 478 4' - 0 " 2' - 8 " 6'-0" 4' - 0 " 2' - 8 " 8'-0" 3'-0" 6' - 8 " 56 11 9' - 0 " 5' - 0 " 15 ' - 1 " F.G. TOP PLATE LINE RIDGE LINE F.F.L. 12 " 3/ 4 " (N ) G Y P C R E T E (E) RAISED FLOOR 1'-6"1'-6" 10 ' - 0 - 3 / 4 " 5' - 0 " 15 ' - 1 " TOP PLATE LINE RIDGE LINE GARAGE F.F.L. / F.G. 12 4 TO MATCH (E) SFD 1 3 7 8 4' - 0 " 2' - 8 " 5'-0" 4' - 0 " 2' - 8 " 5'-0" 3' - 0 " 3' - 8 " 4'-0" 4' - 0 " 2' - 8 " 5'-0" 1 2 34 9' - 0 " 5' - 0 " 15 ' - 1 " F.G. TOP PLATE LINE RIDGE LINE F.F.L. 12 " 3/ 4 " (N ) G Y P C R E T E (E) RAISED FLOOR 1'-6"1'-6" 12 4 TO MATCH (E) SFD 12 34678 4' - 0 " 2' - 8 " 5'-0" 1' - 4 " 5' - 4 " 3'-0"4' - 0 " 2' - 8 " 3'-0" 1' - 4 " 5' - 4 " 3'-0" 3'-0" 6' - 8 " 1 7 89 10 9' - 0 " 5' - 0 " 15 ' - 1 " F.G. TOP PLATE LINE RIDGE LINE F.F.L. 12 " 3/ 4 " (N ) G Y P C R E T E (E) RAISED FLOOR 9' - 0 " 5' - 0 " 15 ' - 1 " F.G. TOP PLATE LINE RIDGE LINE F.F.L. 12 - 3 / 4 " (N) CONC. SLAB 8' - 0 " (E ) T O P P L A T E H T . 9‘ - 0 “ (N ) T O P P L A T E H T . (E) PIER FOOTING (E) FLOOR JOIST (E) SILL PLATE (E) STUD WALL (E) DBL. TOP PLATE (N) MTL. STRAP ON BOTH SIDES (N) STUD WALL EXTENSION (N) RAFTER (N) CEILING JOIST (N) DBL. TOP PLATE (E) STUD WALL 2" MIN.(N) WINDOW FRAME GLAZING (N) WINDOW FRAME (E) HEADER (N) WINDOW TRIM (E) STUD WALL INTERIOR EXTERIOR PROPOSED EXTERIOR ELEVATIONS A-3 X 6 7 EXTERIOR LIGHTING FIXTURE TO MATCH (E) SFD STYLE, MATERIAL 8 ATTIC VENT FASCIA BOARD AT EAVE END MATCH EXISTING MAIN HOUSE AND COLOR KEY NOTES: 1 COMPOSITION (CLASS-A) ROOF SHINGLES COLOR: BROWN 2 EXTERIOR WALL STUCCO, COLOR: CREAM 3 VINYL WINDOW WITH GRILLES 4 EXTERIOR WOOD DOOR MATERIAL AND COLOR 5 VINYL PLAIN PATIO DOOR AND COLOR TO MATCH (E) SFD STYLE, MATERIAL TO MATCH (E) SFD STYLE, WOOD TO MATCH (E) SFD STYLE, MATERIAL WITH 2 LAYERS, COLOR MATCH EXISTING, TO MATCH (E) SFD TEXTURE AND COLOR SLIDING WINDOW ICC# ESAC 438 INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. FRAME COLOR: WHITE COLOR: DARK BROWN FRAME COLOR: WHITE COLOR: WHITE IRON COLOR: DARK BROWN PROPOSED SOUTH ELEVATION PROPOSED EAST ELEVATION PROPOSED WEST ELEVATION 1 2 3 4 5 6 7 Revisions Date Project Name & Address : Sheet Content : AHJ Stamp Approval : Date Drawn By Issue Date By 1st 2nd 3rd Owner : Sheet Number : Sheet :Of : HOME ADDITION 184 Le Roy Ave. Arcadia, CA 91007 Robert S Hsu & Monica C Hsu 9.8.2024 Sarina Truong X Building Correction 9.8.2024 -- -- -- -- -- -- SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" PROPOSED NORTHELEVATION SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" 2 1 4 3 BUT ALL WINDOW CHANGE NO GRID, 2SCALE: N.T.S.RECESSED WINDOW DETAIL 1SCALE: N.T.S.WALL EXTENSION DETAIL 1'-6" 12 4 TO MATCH (E) SFD 9' - 0 " 5' - 0 " 15 ' - 1 " F.G. TOP PLATE LINE RIDGE LINE F.F.L. 12 " 3/ 4 " (N ) G Y P C R E T E (E) RAISED FLOOR 1'-6" 10 ' - 0 - 3 / 4 " 5' - 0 " 15 ' - 1 " TOP PLATE LINE RIDGE LINE GARAGE F.F.L. / F.G. RIDGE BOARD RAFTER CEILING JOIST RADIANT BARRIER RADIANT BARRIER R-38 INSULATION WINDOW, TYP. R-19 INSULATION EXTERIOR WALL, 3-PLY STUCCO, R-19 INSULATION GARAGE BED-2 FLOOR JOIST 18 " CL R . R-19 INSULATION R-15 INSULATION FOUNDATION (E) FLOOR JOIST & FOUNATION(N) FLOOR JOIST & FOUNATION BED-3 BED-4HALLWAY INSTALL MIN. 1/2" GYP. BD THRU ATTIC TO ROOF SHEATHING TO THE GARAGE SIDE R-15 INSULATION R-15 INSULATION R-15 INSULATION ELECTRICAL OUTLET BOX FOR ELECTRICAL RECEPTACLES, SWITCHES, CONTROLS AND DOORBELLS 2x WALL STUD F.F.L. 48 " M A X . 15 " M I N . 12 4 TO MATCH (E) SFD 9' - 0 " 5' - 0 " 15 ' - 1 " F.G. TOP PLATE LINE RIDGE LINE F.F.L. 12 - 3 / 4 " 1'-6" (N) CONC. SLAB EXTERIOR WALL, 3-PLY STUCCO, R-19 INSULATION FLOOR JOIST RAFTER RADIANT BARRIER RIDGE BOARD CEILING JOIST R-38 INSULATION WINDOW, TYP. BED-3KIT. 3/ 4 " (N ) G Y P C R E T E 18 " CL R . R-19 INSULATION R-15 INSULATION FOUNDATION (E) FLOOR JOIST & FOUNATION (N) FLOOR JOIST & FOUNATION 1 2 3 4 5 6 7 Revisions Date Project Name & Address : Sheet Content : AHJ Stamp Approval : Date Drawn By Issue Date By 1st 2nd 3rd Owner : Sheet Number : Sheet :Of : HOME ADDITION 184 Le Roy Ave. Arcadia, CA 91007 Robert S Hsu & Monica C Hsu 9.8.2024 Sarina Truong X Building Correction 9.8.2024 -- -- -- -- -- -- PROPOSED BUILDING SECTIONS A-4 X SCALE: 1/4" = 1'-0" SECTION A-AA 18SCALE: N.T.S.DETAIL 16SCALE: N.T.S.DETAIL 15SCALE: N.T.S.OUTLET BOX DETAIL 14SCALE: N.T.S.13SCALE: N.T.S.1-HOUR FIRE RATED WALL & EAVE SCALE: 1/4" = 1'-0" SECTION B-BB DETAIL DOOR & WINDOW SCHEDULE A-5 X MARK WINDOW TH I C K TY P E SI L L MATERIAL FINISHMATERIALFINISH FRAME HEAD DETAILS JAMB WINDOW SCHEDULE CL E A R G L A S S TI N T E D G L A S S SI N G L E G L A Z E D DB L . G L A Z E D TO P H I N G E SILL REMARKS GENERAL HT . EX I S T I N G NE W SIZE (INCHES) WIDHT x HT.CA S E M E N T HU N G SL I D I N G FI X E D G L A Z I N G BA Y W I N D O W 1 -------GLASS CLEAR VINYL PRE-FIN WINDOW NOTES : 1.VERIFY WINDOW EGRESS HEADERS ON THE FIELD TO COMPLY WITH SILL HEIGHT MAX. 44" TO FINISH FLOOR. 2.THE NET CLEAR OPENING SHALL NOT BE LESS THAN 5.7 SQ. FT. (NOTE: GRADE LEVEL OPENINGS MAY BE MIN 5 SQ. FT.) 3.THE NET CLEAR OPENABLE HEIGHT SHALL BE A MINIMUM OF 20 INCHES. 4.THE NET CLEAR OPENABLE WIDTH SHALL BE A MINIMUM OF 20 INCHES. 5.NOTE: USING BOTH MINIMUM DIMENSIONS WILL NOT OBTAIN THE REQUIRED AREA. 6.THE LOWER EDGE OF THE WINDOW OPENING SHALL BE NOT MORE THAN 44 INCHES ABOVE THE FLOOR. INCHES OF ALL DOORS, EXCEPT AUTOMATIC AND SLIDING, SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE. (CBC 11B-404.2.10) ------2 -A GLASS CLEAR VINYL PRE-FIN 3 -------A GLASS CLEAR VINYL PRE-FIN ------4 -GLASS CLEAR VINYL PRE-FIN 5 -------GLASS CLEAR VINYL PRE-FIN REMARKS SE L F L A T C H I N G D E V . PR I V A C Y L O C K PU S H / P U L L SE L F C L O S I N G D E V . KE Y L O C K AD A S I G N AD A S I G N PA N I C H A R D W A R E TH R E S H O L D DE A D B O L T MARK FINISH SIZE (INCHED) WIDHT x HT. TH I C K TY P E FINISHMATERIAL DOOR MATERIAL FRAME SILLHEADJAMB DETAILS DOOR SCHEDULE IL L U M I N A T E D NE W EX I S T I N G EX I T S I G N VI E W P A N E L / P O R T LA T C H I N G D E V I C E ------ 20 M I N . F I R E R A T E D 1 H O U R F I R E R A T E D 2 H O U R F I R E R A T E D 1 - AD A S I G N ------2 -------3 A WOODPAINTED PAINTED -------4 A WOODPAINTED PAINTED ----5 A WOODPAINTED PAINTED - WOODPAINTED PAINTED A WOODPAINTED PAINTED WINDOW TYPE 'A' SEE SCH'L SE E S C H ' L SE E SC H ' L A 32 B DOOR NOTES : 1.SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES OF THE FINISH FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN THESE SURFACES SHALL BE WITHIN 1/16 INCH OF THE SAME PLANE AS THE OTHER AND BE FREE OF SHARP OR ABRASIVE EDGES. CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED. CBC-11B-404.2.10 2.THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE SHALL BE AS FOLLOWS: CBC-11B-404.2.9 2.1.INTERIOR AND EXTERIOR HINGED DOORS AND GATES, SLIDING, OR FOLDING DOORS: 5 POUNDS MAXIMUM. 2.2.REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS. 3.DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM. CBC-11B-404.2.8.1 4.LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE OPENABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, BY PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. CBC-11B-309.4. 5.HAND0ACTIVATED DOOR OPENING HARDWARE SHALL BE 34" MINIMUM AND 44" MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. WHERE SLIDING DOORS AREA IN THE FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. CBC-11B-404.2.7. 6.THE BOTTOM 10 INCHES OF ALL DOORS, EXCEPT AUTOMATIC AND SLIDING, SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE. (CBC 11B-404.2.10) DOOR TYPE 'A' SEE SCH'L SE E S C H E D U L E ------6 A WOODPAINTED PAINTED -7 8 9 32 * 80 A A A H.C. H.C.------WOODPAINTED PAINTED --- ---WOODPAINTED PAINTED ------WOODPAINTED PAINTED --- 6 -------GLASS CLEAR VINYL PRE-FINA F.F.L. 36 * 80 36 * 80 36 * 80 36 * 80 36 * 80 H.C. H.C. 1-3/8"A 36 * 80 - - -10 ------WOODPAINTED PAINTED S.C. 7 8 9 10 11 -------A GLASS CLEAR VINYL PRE-FIN -------A GLASS CLEAR VINYL PRE-FIN -------A GLASS CLEAR VINYL PRE-FIN -------GLASS CLEAR VINYL PRE-FIN -------GLASS CLEAR VINYL PRE-FIN A A ---11 36 * 80 32 * 80 36 * 80 F.F.L. A-------WOODPAINTED PAINTED --- --- 60 * 48 48 * 36 60 * 48 H.C. S.C. 28 * 80 H.C. A 60 * 48 96 * 48 72 * 48 36 * 48 36 * 16 36 * 16 3260 * 48 A 1 2 3 4 5 6 7 Revisions Date Project Name & Address : Sheet Content : AHJ Stamp Approval : Date Drawn By Issue Date By 1st 2nd 3rd Owner : Sheet Number : Sheet :Of : HOME ADDITION 184 Le Roy Ave. Arcadia, CA 91007 Robert S Hsu & Monica C Hsu 9.8.2024 Sarina Truong X Building Correction 9.8.2024 -- -- -- -- -- -- S.C. H.C. H.C. 60 * 48 32 32 32 32 32 32 44 64 64 WINDOW TYPE 'B' SEE SCH'L SE E S C H ' L SE E SC H ' L Basements, habitable attics and every sleeping room shall have at least one operable emergency escape and rescue opening having a minimum net clear opening of 5.7 square feet except for grade floor openings shall have a minimum net clear opening of 5 square feet. The min. net clear opening height shall be 24 in., width shall be 20 in. min., and bottom of the clear opening shall be no greater than 44 inches measured from the floor. Operable windows with sills located more than 72 inches above finished grade, the lowest part of the clear opening of the window shall be at a height not less than 36 inches above the finished floor surface of the room in which the window is located. Operable sections of windows shall not permit openings that allow passage of a 4-inch-diameter sphere where such openings are located within 36 inches of the finished floor. 12 192 * 84 B-------WOODPAINTED PAINTEDMETAL LIFT UP GARAGE DOOR SEE SCH'L SE E S C H E D U L E DOOR TYPE 'B' CALIFORNIA GREEN CODE GN-1 X 1 2 3 4 5 6 7 Revisions Date Project Name & Address : Sheet Content : AHJ Stamp Approval : Date Drawn By Issue Date By 1st 2nd 3rd Owner : Sheet Number : Sheet :Of : HOME ADDITION 184 Le Roy Ave. Arcadia, CA 91007 Robert S Hsu & Monica C Hsu 9.8.2024 Sarina Truong X Building Correction 9.8.2024 -- -- -- -- -- -- CALIFORNIA GREEN CODE GN-2 X 1 2 3 4 5 6 7 Revisions Date Project Name & Address : Sheet Content : AHJ Stamp Approval : Date Drawn By Issue Date By 1st 2nd 3rd Owner : Sheet Number : Sheet :Of : HOME ADDITION 184 Le Roy Ave. Arcadia, CA 91007 Robert S Hsu & Monica C Hsu 9.8.2024 Sarina Truong X Building Correction 9.8.2024 -- -- -- -- -- --