Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Plans
KIDSTRONG 320 E HUNTINGTON DRIVE ARCADIA, CA 91006 A R C H I T E C T CONTACT INFORMATION 1a.TO THE FULLEST EXTENT PERMITTED BY LAW. THE CONTRACTOR SHALL WAIVE ANY RIGHT OF CONTRIBUTION AND SHALL INDEMNIFY AND HOLD HARMLESS THE OWNER, ARCHITECT OF RECORD, AND ENGINEER AND THEIR AGENTS AND EMPLOYEES AND CONSULTANTS FROM AND AGAINST ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING BUT NOT LIMITED TO ATTORNEYS FEES ARISING OUT OF OR RESULTING FROM OR IN CONNECTIONS WITH THE PERFORMANCE OF THE WORK PROVIDED THAT ANY SUCH CLAIM, DAMAGE, LOSS OR EXPENSE IS CAUSED IN WHOLE OR IN PART BY ANY NEGLIGENT ACT OR OMISSION OF THE CONTRACTOR OR ANY SUBCONTRACTOR. ANYONE DIRECTLY OR INDIRECTLY EMPLOYED BY ANY OF THEM OR ANYONE FOR WHOSE ACTS ANY OF THEM MAY BE LIABLE. REGARDLESS OF WHETHER OR NOT IT IS CAUSED IN PART BY A PARTY INDEMNIFIED HEREUNDER. SUCH OBLIGATION SHALL NOT BE CONSTRUED TO NEGATE, ABRIDGE, OR OTHERWISE REDUCE ANY OTHER RIGHT OR OBLIGATION OF INDEMNITY; WHICH WOULD OTHERWISE EXIST AS TO ANY PARTY OR PERSON DESCRIBED IN THIS AGREEMENT. 1b.IN ANY AND ALL CLAIMS AGAINST THE OWNER, ARCHITECT OF RECORD, AND ENGINEERS OR ANY OF THEIR AGENTS OR EMPLOYEES AND CONSULTANTS BY ANY EMPLOYEE OF THE CONTRACTOR, ANY SUBCONTRACTOR, ANYONE DIRECTLY OR INDIRECTLY EMPLOYED BY ANY OF THEM OR ANYONE FOR WHOSE ACTS ANY OF THEM MAY BE LIABLE. THE INDEMNIFICATION OBLIGATION UNDER THIS PARAGRAPH AGREEMENT SHALL NOT BE LIMITED IN ANY WAY BY AN LIMITATION ON THE AMOUNT OR TYPES OF DAMAGES; COMPENSATION OR BENEFITS PAYABLE BY OR FOR THE CONTRACTOR OR ANY SUBCONTRACTOR UNDER WORKS OR WORKMEN'S COMPENSATION ACTS. DISABILITY BENEFITS ACTS OR OTHER EMPLOYEE BENEFITS ACTS. 1c."CLAIMS, DAMAGES, LOSSES AND EXPENSES" AS THESE WORDS ARE USED IN THIS AGREEMENT, SHALL BE CONSTRUED TO INCLUDE, BUT NOT LIMITED TO (1) INJURY OR DAMAGE CONSEQUENT UPON THE FAILURE OF OR USE OR MISUSE BY CONTRACTOR, IT'S SUBCONTRACTOR, AGENTS, SERVANTS OR EMPLOYEES OF ANY HOIST, RIGGING, BLOCKING, SCAFFOLDING, OR ANY AND ALL OTHER KINDS OF ITEMS OF EQUIPMENT, OWNED, FURNISHED OR LOANED BY OWNER; (2) ALL ATTORNEY'S FEES AND COSTS INCURRED IN BRINGING AN ACTION TO ENFORCE THE PROVISIONS OF THIS INDEMNITY OR ANY OTHER INDEMNITY CONTAINED IN THE GENERAL CONDITIONS, AS MODIFIED BY THE SUPPLEMENTARY GENERAL CONDITIONS, AND (3) TIME EXPENDED BY THE PARTY BEING INDEMNIFIED AND THEIR EMPLOYEES AT THEIR USUAL RATES PLUS COSTS OF TRAVEL, LONG DISTANCE TELEPHONE AND REPRODUCTION OF DOCUMENTS. 1d.IF THE PROJECT IS IN A STATE WHICH PROHIBITS PARTIES FROM BEING INDEMNIFIED AGAINST THEIR OWN NEGLIGENCE, AN ADDITIONAL MODIFICATION SHOULD BE: "THE OBLIGATIONS OF THE CONTRACTOR UNDER THIS AGREEMENT SHALL NOT EXTEND TO THE LIABILITY OF THE OWNER, ARCHITECT/ ENGINEER, THEIR AGENTS OR EMPLOYEES ARISING OUT OF THEIR NEGLIGENCE". INSURANCE REQUIREMENTS DRAWING INDEX DXU, LLC 412 S. WELLS ST. SECOND FLOOR CHICAGO, IL 60607 (P) 312.955.0334 CONTACT: ANKITA MANSHARAMANI PROJECT MANAGER amansharamani@dxuarch.com CONDITIONAL USE PERMIT RE V 1 RE V 2 RE V 3 SYMBOLS KEY DETAIL TAGS SHEET DESIGNATION DETAIL NUMBER DRAWING TITLE TAG DRAWING SCALE DETAIL NUMBER DRAWING TITLE NORTH ARROW DETAIL TAGS SHEET DESIGNATION DETAIL NUMBER SECTION TAG DETAIL CALLOUT INTERIOR ELEVATION TAG EXTERIOR ELEVATION TAG SHEET DESIGNATION DETAIL NUMBER TAG SYMBOLS INTERIOR DOOR TAG EQUIPMENT TAG WINDOW / EXTERIOR DOOR TAG KEYNOTE TAG REVISION TAG ELEVATION TAG ELEVATION ITEM ELEVATION FINISH TAG WALL TYPE TAG FLOOR FINISH TAG DRAWING SYMBOLS ROOM TAG ROOM NAME ROOM NUMBER FLOOR FINISH FLOOR FINISH WALL FINISH BASE FINISH COLUMN TAG MATCH LINE CENTER LINE BREAK LINE NTS NAMEXX XX XX XX XX XX XX XXXX XX XXXX XX XX XX XX XX XX R-XX'-XX" R-XXX XXXX XXXX XX XX X X CL XX ABBREVIATIONS AB anchor bolt ABV above AD area drain AFF above finish floor ALUM aluminum ANN annunciator APROX approximate ARCH architectural AUTO automatic AVE avenue AWG American wire gauge B/bottom of BIT bituminous BLDG building CL center line CLG ceiling CM centimeter CMU concrete masonry unit CO cleanout COL column CONC concrete CONT continuous COORD coordinate CNTR center CU cubic CW cold water DBL double DEG degree DEMO demolish DEPT department DET detail DIA diameter DIAG diagonal DN down DS downspout DWG drawing E East ELEC electrical EM emergency EXIST existing EXT exterior F/face of FA fire alarm FCO floor clean out FD floor drain FNDN foundation FF finish floor FLR floor FT foot (feet) FTG footing FURR furring GA gauge GALV galvanized GND ground GWB gypsum wall board GYP gypsum HB hose bib HDWH hardwood HDWR hardware HR hour HT height HW hot water ID inside diameter IN inches INCL include(d)(ing) INSUL insulation INT interior KO knockout KIT kitchen LAM laminate(s) LAV lavatory LB(S)pound(s) LL landlord LT light M meter MAINT maintenance MAS masonry MAX maximum MECH mechanical MTL metal MEZZ mezzanine MFR manufacturer MIN minimum MISC miscellaneous MM millimeter MO masonry opening MULL mullion N North N.I.C.not in contract NO.number NOM nominal NTS not to scale OA overall OC on center OD outside diameter OH overhead OPNG opening PL plate P-LAM plastic laminate PLBG plumbing PLUMB plumbing PNL panel PNT paint PT pressure treated QT quarry tile R riser RD roof drain REF refrigerator REINF reinforced REQ'D required REV revision RFG roofing RM room RMV remove RO rough opening S South SAFB sound attenuation fire batt insulation SAN sanitary SECT section SF square foot (feet) SIM similar SQ square SS stainless steel STC sound transmission class STD standard STL steel STRUCT structural T tread T/top of T&B top and bottom T&G tongue and groove TEL telephone TEMP tempered TOPO topography(ic) TYP typical UNO unless noted otherwise UTIL utility VAC vacuum VTR vent through roof VIF verify in field W West W/with W/O without WC water closet WH water heater WIN window WWF welded wire fabric YD yard RE V 1 RE V 2 RE V 3 C L I E N T KIDSTRONG 3801 PARKWOOD BLVD SUITE 301, FRISCO TX 75034 XX XX XX X XX X TText BText Rm No CONTACT: BETH HERSH beth.hersh@kidstrong.com M P E E N G I N E E R CASE ENGINEERING INC. 796 MERUS COURT. LOUIS, MO 63026 636.349.1600 EXT. 228 CONTACT: LUKE WILD lwild@caseengineering.com FRANCHISEE INFO NAILAH ELMASRI nailah.elmasri@kidstrong.com GENERAL T1-01 TITLE SHEET G1-01 PROJECT INFO & CODE ANALYSIS G3-01 SITE PLAN G3-02 VISION TRIANGLES PLAN G3-03 PARKING ANALYSIS ARCHITECTURAL A1-02 FLOOR PLAN A2-01 REFLECTED CEILING PLAN A6-01 EXTERIOR ELEVATIONS X X X X X X X X No . Is s u e Da t e SE A L MUNICIPAL APPROVAL STAMP 32 0 E H U N T I N G T O N D R I V E AR C A D I A , C A 9 1 0 0 6 41 2 S . W e l l s S t r e e t 2 n d F l o o r C h i c a g o I L 6 0 6 0 7 P: 3 1 2 9 5 5 0 3 3 4 d x u a r c h . c o m AR C H I T E C T CO N S U L T A N T S CL I E N T PR O J E C T Pr o j e c t N u m b e r : Dr a w n B y : Ap p r o v e d B y : These documents are confidential and shall be in the possession of authorized individuals only. These documents are the exclusive property of DxU architects and shall not be copied or reproduced without written authorization. SHEET TITLE & NUMBER KI D S T R O N G IS S U E F O R P E R M I T 25 - 0 2 2 YP AM © D x U 2 0 2 1 PL O T D A T E : 5/ 1 / 2 0 2 5 9 : 0 4 A M PL O T T E D B Y : YU R I T Z Y P E R E Z CO N D I T I O N A L U S E P E R M I T 20 2 5 / 0 3 / 0 6 ZO N I N G & F I R E C O M M E N T S 20 2 5 / 0 5 / 0 1 1 1 1 1 TITLE SHEET T1-01 PROJECT LOCATION PROJECT DESCRIPTION OCCUPANCY DIAGRAM SCALE = NTS CBC 2022 CODE MATRIX TYPE IIB (SPRINKLERED) INTERIOR FINISHES:ALL INTERIOR FINISHES/MATERIALS SHALL COMPLY WITH CHAPTER 8 OF THE 2022 CBC NOTES:PROJECT MUST FULLY COMPLY & MEET ALL ACCESSIBILITY REQUIREMENTS OF THE AMERICAN DISABILITIES ACT, 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN & THE 2022 CBC (MOST RESTRICTIVE REQUIREMENTS GOVERN). DESCRIPTION AREA AREA PER OCCUPANT TOTAL OCCUPANTS SCOPE OF WORK: OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: A-3, ASSEMBLY (PROPOSED) B, BUSINESS (EXISTING) CHILDREN'S EDUCATIONAL ENRICHMENT CENTER - INTERIOR BUILDOUT EXISTING BUILDING, NO CHANGEALLOWABLE HEIGHT: EXISTING BUILDING, 1 STORYACTUAL HEIGHT: EXISTING BUILDING, NO CHANGEALLOWABLE AREA: 3690 SFTENANT SPACE GROSS AREA: A-3 TO B (ADJACENT), 1HR REQUIREDSEPARATION - USES: FIRE RESISTANCE RATING REQUIREMENT (TABLE 601)BUILDING ELEMENT 0 HRSTRUCTURAL FRAME: BEARING WALLS, EXTERIOR: BEARING WALLS, INTERIOR: NON-BEARING WALLS, EXT.: NON-BEARING WALLS, INT.: FLOOR CONSTRUCTION: ROOF CONSTRUCTION: 0 HR 0 HR 0 HR 0 HR 0 HR 0 HR REQUIRED PROVIDED EXISTING EXISTING EXISTING EXISTING 1 HR (DEMISING WALLS) EXISTING EXISTING EXISTING BUILDING, NO CHANGEACTUAL AREA: EGRESS CALCULATIONS 27DEVELOPMENT FLOOR 1 1,316 SF (GROSS)50 (GROSS) 91TOTAL OCCUPANT LOAD (TABLE 1004.1.2) OCCUPANCY LOAD CALCULATIONS: EXIT ACCESS TRAVEL DISTANCE: MAX. ALLOWED MAX. DISTANCE PROVIDED 83'-3" EGRESS DOOR WIDTH:36" MINIMUM REQUIRED PROVIDED EXIT 1 - 36" EXIT 2 - 36" EXIT 3 - 36" MINIMUM NUMBER OF EXITS: (TABLE 1006.3.1)2 REQUIRED PROVIDED 3 PLUMBING REQUIREMENTS (2022 CBC) CITY OF ARCADIA BLDG CODES CHILDREN'S EDUCATIONAL ENRICHMENT CENTER - INTERIOR BUILDOUT SPRINKLERED 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN ENERGY PLUMBING ELECTRICAL 2022 CALIFORNIA ELECTRICAL CODE MECHANICAL BUILDING 2022 CALIFORNIA BUILDING CODE* AS AMENDED PER ARCADIA CITY CODES* * * FIRE PREVENTION 2022 CALIFORNIA FIRE CODE ACCESSIBILITY * EGRESS AISLE WIDTH:44"48" 250' * * (TABLE 1016.2) STORAGE/UTILITY:125 SF (GROSS)300 SF (GROSS) MERCANTILE (RETAIL, LOBBY, RECEPTION):115 SF (GROSS)60 (GROSS) STORAGE/ UTILITY (300 SF/ PERSON) 125 SF/300 = 01 OCCUPANT MERCANTILE (RETAIL, LOBBY, RECEPTION) (60 SF/ PERSON) 115 SF/ 60 = 02 OCCUPANT VIEWING AREAS VIEWING AREA 1 129 SF (OCCUPANTS DETERMINED BY THE AMOUNT OF PEOPLE THE SPACE IS DESIGNED FOR) 17 SEATS = 17OCCUPANTS LEGEND EGRESS / ACCESS DIAGRAM EXIT ACCESS TRAVEL DISTANCE MAX. DISTANCE = 83'-3" REFER TO A1-04 DIMENSIONED PLAN FOR EGRESS AISLE WIDTHS & REFER TO A2-01 REFLECTED CEILING PLAN FOR EMERGENCY LIGHTS & EXIT SIGN LOCATIONS. ADA COMPLIANCE NOTES ADA COMPLIANT SERVICE AREA: (IBC 1108.2.9.1) REQUIRED PROVIDED 2022 CALIFORNIA BUILDING ENERGY CODE 02 01 28DEVELOPMENT FLOOR 2 1,359 SF (GROSS)50 (GROSS) DEVELOPMENT FLOORS (50 SF/ PERSON) DEVELOPMENT FLOOR 1 1,316 SF/50 = 27 OCCUPANTS DEVELOPMENT FLOOR 2 1,359 SF/50 = 28 OCCUPANTS TOTAL 55 OCCUPANTS LEGEND EGRESS TRAVEL COMMON PATH OF TRAVEL DISTANCE: MAX. ALLOWED MAX. DISTANCE PROVIDED N/A75' PROXIMITY MAP FLOOR PLAN SITE PLAN SCALE = NTS MIN. NO. OF PLUMBING FIXTURES MALE PROVIDED WATER CLOSETS:1 REQUIREMENT FEMALE 1 PER 125 = 1 REQUIRED MALE FEMALE 1 LAVATORIES:1 1 PER 200 = 1REQUIRED 1 PER 200 = 1 REQUIRED 1 DRINKING FOUNTAINS:21 PER 500 SERVICE SINK:11 1 PER 65 = 1 REQUIRED 45 OCCUPANTSNUMBER OF OCCUPANTS:45 OCCUPANTS MINIMUM NUMBER OF PLUMBING FIXTURES AND REQUIREMENT CALCULATIONS PER 2022 CALIFORNIA BUILDING CODE CHAPTER 29 PLUMBING SYSTEMS SCALE = NTS 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE GREEN BUILDING* * 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE VIEWING AREA 1 129 SF (GROSS) VIEWING AREA 2 57 SF (GROSS) N/A. OCCUPANTS DETERMINED BY THE AMOUNT OF PEOPLE THE SPACE IS DESIGNED FOR 17 SEATS = 17 OCCUPANTS N/A. OCCUPANTS DETERMINED BASED ON SEAT LENGTH / 18" PER PERSON 16 SEATS = 16 OCCUPANTS 17 16 VIEWING AREA 2 BASED ON SEAT LENGTH / 18" PER PERSON 16 SEATS = 16 OCCUPANTS TOTAL 33 OCCUPANTS SCALE = NTS FLOOR PLAN TOTAL OCCUPANCY 91 OCCUPANTS 320 E HUNTINGTON DR, ARCADIA, CA 91006 NO PARKING NO PAR K I N G HUNTINGTON DRIVE GA T E W A Y D R I V E NO PARKING A EXIT 1 A TO 1 83'-3" EXIT 2 B TO 2 33'-6" 9 4 ' - 3 " 1 3 = 3 1 ' - 5 " C EXIT 3 NIC NIC B C TO 3 67'-2" 14'- 0 " No . Is s u e Da t e SE A L MUNICIPAL APPROVAL STAMP 32 0 E H U N T I N G T O N D R I V E AR C A D I A , C A 9 1 0 0 6 41 2 S . W e l l s S t r e e t 2 n d F l o o r C h i c a g o I L 6 0 6 0 7 P: 3 1 2 9 5 5 0 3 3 4 d x u a r c h . c o m AR C H I T E C T CO N S U L T A N T S CL I E N T PR O J E C T Pr o j e c t N u m b e r : Dr a w n B y : Ap p r o v e d B y : These documents are confidential and shall be in the possession of authorized individuals only. These documents are the exclusive property of DxU architects and shall not be copied or reproduced without written authorization. SHEET TITLE & NUMBER KI D S T R O N G IS S U E F O R P E R M I T 25 - 0 2 2 YP AM © D x U 2 0 2 1 PL O T D A T E : 5/ 1 / 2 0 2 5 9 : 0 6 A M PL O T T E D B Y : YU R I T Z Y P E R E Z CO N D I T I O N A L U S E P E R M I T 20 2 5 / 0 3 / 0 6 ZO N I N G & F I R E C O M M E N T S 20 2 5 / 0 5 / 0 1 1 1 1 1 1 1 1 1 1 PROJECT INFO & CODE ANALYSIS G1-01 01 SITE PLAN 1/32" = 1'-0" EXISTING ACCESSIBLE PARKING 2 ACCESSIBLE ROUTE 3 PARCEL PROPERTY LINE 4 EXISTING SIDEWALK 5 EXISTING ACCESSIBLE PARKING SIGN KEYNOTES EXISTING LANDSCAPE PARCEL PROPERTY LINE ACCESSIBLE ROUTE PROPOSED TENANT SPACE ADJACENT TENANT SPACE NO PARKING N O PA R K I N G HUNTINGTON DRIVE GATEWAY DRI NO PARKING KIDSTRONG SPACE (PROPOSED TENANT SPACE) 2 4 ' - 7 " 8'-5" 7 1 ' - 0 1 2" 1 A C C E S S I B L E R O U T E 63' - 6 " 74 ' - 6 " 7'-8" 5'-1 0 1 2" 1 2 31 5 45 SUMI LASHES NIRVANA INDIAN CUISINE DELI SANDWICHES AUTO INSURANCE STARBUCKS MAKI SUSHI TASTEA COSMO BEAUTY SUPPLIES BANK OF AMERICA (FUTURE) DASHIWA RAMEN VACANT VACANT No . Is s u e Da t e SE A L MUNICIPAL APPROVAL STAMP 32 0 E H U N T I N G T O N D R I V E AR C A D I A , C A 9 1 0 0 6 41 2 S . W e l l s S t r e e t 2 n d F l o o r C h i c a g o I L 6 0 6 0 7 P: 3 1 2 9 5 5 0 3 3 4 d x u a r c h . c o m AR C H I T E C T CO N S U L T A N T S CL I E N T PR O J E C T Pr o j e c t N u m b e r : Dr a w n B y : Ap p r o v e d B y : These documents are confidential and shall be in the possession of authorized individuals only. These documents are the exclusive property of DxU architects and shall not be copied or reproduced without written authorization. SHEET TITLE & NUMBER KI D S T R O N G IS S U E F O R P E R M I T 25 - 0 2 2 YP AM © D x U 2 0 2 1 PL O T D A T E : 5/ 1 / 2 0 2 5 9 : 1 4 A M PL O T T E D B Y : YU R I T Z Y P E R E Z CO N D I T I O N A L U S E P E R M I T 20 2 5 / 0 3 / 0 6 ZO N I N G & F I R E C O M M E N T S 20 2 5 / 0 5 / 0 1 1 SITE PLAN G3-01 NO PARKING NO PA R K I N G HUNTINGTON DRIVE GA T E W A Y D R I V E NO PARKING 1 2 3 4 5 6 7 8 KIDSTRONG SPACE (PROPOSED TENANT SPACE) 01 POINT OF VIEW NTS 02 POINT OF VIEW NTS 03 POINT OF VIEW NTS 04 POINT OF VIEW NTS 05 POINT OF VIEW NTS 06 POINT OF VIEW NTS 07 POINT OF VIEW NTS 08 POINT OF VIEW NTS11VISION TRIANGLE PLAN NTS No . Is s u e Da t e SE A L MUNICIPAL APPROVAL STAMP 32 0 E H U N T I N G T O N D R I V E AR C A D I A , C A 9 1 0 0 6 41 2 S . W e l l s S t r e e t 2 n d F l o o r C h i c a g o I L 6 0 6 0 7 P: 3 1 2 9 5 5 0 3 3 4 d x u a r c h . c o m AR C H I T E C T CO N S U L T A N T S CL I E N T PR O J E C T Pr o j e c t N u m b e r : Dr a w n B y : Ap p r o v e d B y : These documents are confidential and shall be in the possession of authorized individuals only. These documents are the exclusive property of DxU architects and shall not be copied or reproduced without written authorization. SHEET TITLE & NUMBER KI D S T R O N G IS S U E F O R P E R M I T 25 - 0 2 2 YP AM © D x U 2 0 2 1 PL O T D A T E : 5/ 1 / 2 0 2 5 9 : 2 2 A M PL O T T E D B Y : YU R I T Z Y P E R E Z CO N D I T I O N A L U S E P E R M I T 20 2 5 / 0 3 / 0 6 ZO N I N G & F I R E C O M M E N T S 20 2 5 / 0 5 / 0 1 1 VISION TRIANGLE PLAN G3-02 01 PARKING SITE PLAN 1/64" = 1'-0" KEY LEGEND PATH TO PARKING STRUCTURE STREET PARKING NO PARKING NO PA R K I N G HUNTINGTON DRIVE GA T E W A Y D R I V E NO PARKING S 5 T H A V E NO PARKINGNOPARKING KIDSTRONG SPACE (PROPOSED TENANT SPACE) SUMI LASHES NIRVANA INDIAN CUISINE DELI SANDWICHES AUTO INSURANCE POOL SUPPLIES STARBUCKS MAKI SUSHI TASTEA COSMO BEAUTY SUPPLIES BANK OF AMERICA (FUTURE) DASHIWA RAMEN 3 STORY PARKING STRUCTURE 236 - PARKING SPACES PATH TO PARKING STRUCTURE OLIVE GARDENBJ's RESTAURANT OFFICES AAA INSURANCE VACANT VACANT OFFICE BUILDING 115 No . Is s u e Da t e SE A L MUNICIPAL APPROVAL STAMP 32 0 E H U N T I N G T O N D R I V E AR C A D I A , C A 9 1 0 0 6 41 2 S . W e l l s S t r e e t 2 n d F l o o r C h i c a g o I L 6 0 6 0 7 P: 3 1 2 9 5 5 0 3 3 4 d x u a r c h . c o m AR C H I T E C T CO N S U L T A N T S CL I E N T PR O J E C T Pr o j e c t N u m b e r : Dr a w n B y : Ap p r o v e d B y : These documents are confidential and shall be in the possession of authorized individuals only. These documents are the exclusive property of DxU architects and shall not be copied or reproduced without written authorization. SHEET TITLE & NUMBER KI D S T R O N G IS S U E F O R P E R M I T 25 - 0 2 2 YP AM © D x U 2 0 2 1 PL O T D A T E : 5/ 1 / 2 0 2 5 9 : 2 8 A M PL O T T E D B Y : YU R I T Z Y P E R E Z CO N D I T I O N A L U S E P E R M I T 20 2 5 / 0 3 / 0 6 ZO N I N G & F I R E C O M M E N T S 20 2 5 / 0 5 / 0 1 1 PARKING SITE PLAN G3-03 1 01 02 03 08 04 19 11 11 19 20 16 07 23 1821 15 21 DEVELOPMENT FLOOR 008 DEVELOPMENT FLOOR 009 RECEPTION 001 VIEWING AREA 007 VIEWING AREA 006 RESTROOM 003 RESTROOM 004 05 18 22 09 10 13 05 C 13 05 C-2 C-1 EX-1 EX-2 EX-3 E-1 E-1 C-4 C-4 E-2 E-2 001 002 003 005 006 006 E-9A 0714 P-4 OFFICE STORAGE/ 002 07 C-6 C-6 12 12 01 FLOOR PLAN 3/16" = 1'-0" KEYNOTES 01 SIGNAGE ABOVE DOOR TO READ "THIS DOOR MUST REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" 02 RETAIL FIXTURE PROVIDED BY KIDSTRONG HQ. SEE DIP FOR MORE INFO.03 2A10BC FULLY RECESSED FIRE EXTINGUISHER MOUNTED IN WALL CABINET04 05 06 PROVIDE BLOCKING IN WALL FOR ALL EQUIPMENT; CABINETS, GRAB BARS, SINKS, D.F., SHELVES, MIRRORS. 07 13 08 OWNER PROVIDED DESK AND GC INSTALLED - OR KID STRONG INSTALLED IF ELECTING WHITE GLOVE. ADA COUNTER 36" HIGH MAX 09 EXISTING SHELL WALL AND STOREFRONT TO REMAIN. PATCH/REPAIR/FINISH AS REQUIRED TO MATCH EXISTING FINISHES. 10 CORPORATE STANDARD 36" GATE. NO LATCHING.11 12 RANK POSTER 24"x36". SEE DIP FOR MORE INFORMATION. 14 15 16 17 18 19 20 21 PATCH AND REPAIR FLOOR AND WALLS AS NEEDED FOR NEW CONSTRUCTION. ELECTRICAL PANELS. REFER TO ELECTRICAL DRAWINGS FOR MORE INFO. PROVIDE CLEAR CORNER GUARDS ON ALL OUTSIDE CORNERS IN HIGH TRAFFIC AREAS. 36" CLEAR TEMPERED GLASS FLOOR DIVIDER W/ 42" GATE OPENING PER PLAN CR LAURENCE CONNECTORS. PULLS COLS3CH AT GATE AND PS36CBS POSTS W/ CAPS AND END CAPS. BUTT UP AT WALLS/ 1" FROM GLASS AT END OF RUN CUBBY BENCH. OWNER PROVIDED AND INSTALLED. SEE DIP FOR MORE INFO. 22 ACCESSIBLE TOILET FACILITY SIGNAGE. VINYL GRAPHICS AREA PROVIDE LEVEL 5 FINISH AT WALLS. GC TO COORDINATE AND PROVIDE VENDOR TO INSTALL. SLIDING DOOR. REFER TO DIP FOR MORE INFO. EXISTING STEEL COLUMN TO REMAIN. 23 PROVIDE MAXIMUM OCCUPANCY SIGN PER 1004.9 AT STUDIO DOORS AND EACH ROOM. 24 TV & COACH'S CUBBY TO BE MOUNTED AT 72" AFF LEGEND NEW PARTITION EXISTING WALL EXISTING WALL WITH NEW FURRING N.I.C. BLOCKING NOTES PROVIDE FTWD BLOCKING (UON) AT THE FOLLOWING LOCATIONS: 1.ACCESSIBLITY REQUIREMENTS & GRAB BARS AT ALL RESTROOM LOCATIONS 2.RESTROOM ACCESSORIES INCLUDING TOILET STALL PARTITIONS & BABY CHANGING TABLE 3.MILLWORK LOCATIONS - TO BE 6" STRIPS 4.CASEWORK AS REQUIRED BY THE MFR & FOR PROPER SUPPORT 5.MANAGER'S DESK SHELVES 25 SOUND BAR TO BE MOUNTED AT 100" AFF CAMERA MOUNTED AT 10' AFF EXISTING REAR DOOR TO REMAIN, PROVIDE PANIC BAR IF NOT EXISTING. PROTECT DURING CONSTRUCTION. PROVIDE NEW MOP SINK. PROVIDE FRP SURFACE BEHIND SINK 26 EX-4 EXISTING DOOR ROTATED. REPAIR AS REQUIRED. PROVIDE PANIC BAR IF NOT EXISTING. A3-01 01 A7-01 01 24 24 25 25 25 25 26 C 26 C 26 09 RELOCATED ELECTRICAL PANEL, SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION.27 27 0714 EQUIPMENT SCHEDULE ITEM #DESCRIPTION MANUFACTURER MODEL FINISH COMMENTS E-1 WALL-MOUNT TELEVISION SAMSUNG/ LEADZM UN65TU7000FXZA TV. WITH TMXD-103 SWIVEL MOUNT -PROVIDE NEW IN-WALL BLOCKING E-2 SOUND BAR SAMSUNG HW-S60TIZA -PROVIDE NEW IN-WALL BLOCKING E-3 PARLETTE WALL RACK KIDSTRONG --PROVIDE NEW IN-WALL BLOCKING E-4 POLE MOUNT E-5 BEVERAGE COOLER NEWAIR AB-1200 BLACK E-6 KRAWLER WALL RACK KIDSTRONG --PROVIDE NEW IN-WALL BLOCKING E-9A FIRE EXT. CABINET (RECESSED)POTTER ROEMER 7008-DV-PRFH-PRVDFI-BL CABINET WITH 3005 EXTINGUISHER (5 LB. 2A)WHITE PROVIDE NEW IN-WALL BLOCKING *CASEWORK SCHEDULE ITEM #DESCRIPTION NOTES C-1 RECEPTION DESK ASSEMBLY REQUIRED C-2 RETAIL CABINET ASSEMBLY REQUIRED C-3 RETAIL WALL RACK ASSEMBLY REQUIRED, PROVIDE NEW IN WALL BLOCKING C-4 COACH STATION AND WALL BRACKET ASSEMBLY REQUIRED, PROVIDE NEW IN WALL BLOCKING C-5 STORAGE CUBBY ASSEMBLY REQUIRED C-6 CUBBY BENCH *CONFIRM WITH AD IF ELECTING WHITE GLOVE - THEN WILL BE GC TO COORDINATE WITH KS EQUIPMENT TEAM WHO WILL PROVIDE AND INSTALL GC TO ADD 5/8" GYP BOARD AT ALL EXISTING CONDITIONS WITH EXPOSED METAL STUD. VERIFY IN FIELD TO PROVIDE PROPER BIDS NOTE: ALL WOOD BLOCKING TO BE FIRE-RET TREATED. SECURE EXISTING DOORS CLOSED. REMOVE DOOR HARDWARE. DOOR TO REMAIN CLOSED AT ALL TIMES. NEW HIGH/LOW ADA COMPLIANT DRINKING FOUNTAIN, REFER TO PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. 06 06 06 No . Is s u e Da t e SE A L MUNICIPAL APPROVAL STAMP 32 0 E H U N T I N G T O N D R I V E AR C A D I A , C A 9 1 0 0 6 41 2 S . W e l l s S t r e e t 2 n d F l o o r C h i c a g o I L 6 0 6 0 7 P: 3 1 2 9 5 5 0 3 3 4 d x u a r c h . c o m AR C H I T E C T CO N S U L T A N T S CL I E N T PR O J E C T Pr o j e c t N u m b e r : Dr a w n B y : Ap p r o v e d B y : These documents are confidential and shall be in the possession of authorized individuals only. These documents are the exclusive property of DxU architects and shall not be copied or reproduced without written authorization. SHEET TITLE & NUMBER KI D S T R O N G IS S U E F O R P E R M I T 25 - 0 2 2 YP AM © D x U 2 0 2 1 PL O T D A T E : 5/ 1 / 2 0 2 5 9 : 3 1 A M PL O T T E D B Y : YU R I T Z Y P E R E Z CO N D I T I O N A L U S E P E R M I T 20 2 5 / 0 3 / 0 6 ZO N I N G & F I R E C O M M E N T S 20 2 5 / 0 5 / 0 1 1 FLOOR PLAN A1-02 1 1 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L1 L1 L1 L1 L1 L4 EX-2 EX-2 EX-2 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 EX-2 EX-2 EX-2 EX-2 L4 EX-2 L6 L6 EX-2 L1 L6 L6 L6 L6 L6 L6 01 REFLECTED CEILING PLAN 3/16" = 1'-0" DEVELOPMENT AREA 008 FINISH ACT1 B/ ACT CEILING EL: ± (11'-6" AFF) DEVELOPMENT AREA 009 FINISH ACT1 B/ ACT CEILING EL: ± (11'-6" AFF) VIEWING AREA 007 ACT1 B/ ACT CEILING EL: ± (10'-0" AFF) FINISH VIEWING AREA 006 ACT1 B/ ACT CEILING EL: ± (10'-0" AFF) FINISH ADA RESTROOM 004 FINISH P-2 B/GYP BD EL: ± (9'-0" AFF) FINISH ACT1 B/ ACT CEILING EL: ± (10'-0" AFF) HALLWAY 004 FINISH ACT1 B/ ACT CEILING EL: ± (10'-0" AFF) BACK VESTIBULE 008 FINISH ACT1 B/ ACT CEILING EL: ± (9'-0" AFF) RECEPTION 001 ACT1 B/ ACT CEILING EL: ± (10'-0" AFF) FINISH OFFICE STORAGE/ 002 KEYNOTES 01 02 SOFFIT ALIGNED WITH PONY WALL. ADA RESTROOM 003 FINISH P-2 B/GYP BD EL: ± (9'-0" AFF) E Q E Q EQ EQ E Q EQ EQ E Q 01 EXISTING STRUCTURAL COLUMN. 02 02 RCP GENERAL NOTES 1.BREAKERS SERVING EMERGENCY LIGHTING AND EXIT SIGNS TO BE LOCKED ON AT CIRCUIT BREAKER. LOCK WILL ALLOW CIRCUIT BREAKER TO TRIP IN EVENT OF OVERLOAD. 2.REFER TO A7-01 FOR CEILING DETAILS AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 3.ALL LIGHT FIXTURES TO BE INSTALLED FOR MANUFACTURERS SPECS. 4.ELECTRICIAN TO FOLLOW SWITCHING GUIDELINES ILLUSTRATED ON E2.0. 5.ALL VOLTAGE REQUIREMENTS ARE THE RESPONSIBILITY OF THE ELECTRICIAN INSTALLING THE SPECIFIED LIGHT FIXTURE. 6.CONTRACTORS/INSTALLER IS RESPONSIBLE FOR VERIFYING ALL DIMENSIONS. NOTIFY DESIGNERS OF ANY DISCREPANCIES AS THEY BECOME EVIDENT. 7.ALL DIFFUSERS TO BE PAINTED TO MATCH CEILING. 8.MAINTAIN DUCT WORK AS HIGH AS POSSIBLE, ANY EXPOSED DUCTWORK IS TO BE INTERNALLY LINED AND PAINTED TO MATCH P-3 ICE CUBE SILVER. 9.ELECTRICIAN TO PROVIDE EMERGENCY/SAFETY LIGHTING, SWITCHES, OUTLETS, ETC. 10.SWITCH PLATES & OUTLETS TO BE LEVITON RENOIR STYLE OR EQUAL. COLOR TO MATCH ADJACENT FINISH U.O.N. (WHITE CONTROLS & COVER PLATES AT WALL WITH LIGHT FINISH) VERTICAL INSTALLATION TYPICAL, ALWAYS WHITE. HORIZONTAL ABOVE COACH'S CUBBY ONLY. 11.PROVIDE OUTLETS IN EVER ROOM FOR VACUUMS AN ALONG CORRIDORS. 12.ENSURE INTERIOR GRAPHIC LOCATION DO NOT INTERFERE WITH ANY DEVICES. 13.ALL LOCATIONS WITH MULTIPLE LIGHT SWITCHES SHALL BE GANGED WITH A SINGLE COVER PLATE. 14.EXPOSED PIPE, CONDUITS, ETC. IN PUBLIC AREAS SHALL BE PAINTED TO MATCH ADJACENT SURFACE IF AT EXPOSED CEILING. 15.ALL LOBBY, RECEPTION DESK, LIGHTING TO BE ON DIMMERS, SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. ONLY IF REQUIRED BY CODE. 16.GC TO PROVIDE SHOP DRAWINGS FOR ALL HVAC. LIGHT FIXTURE SCHEDULE ITEM #DESCRIPTION MANUFACTURER: CATALOG #WATTAGE VOLTAGE NOTES L1 2X2 BACKLIT LED FLAT PANEL COLOR AND WATTAGE SELECTABLE WITH WHITE FINISH DIMMABLE 0-10V (COLOR TEMP TO BE SET TO 3500K/WATTAGE TO BE SET TO 0WATTS) ENVISION: LED-BPL-2X2-3M40-5CCT 40 WATTS 120V FOR LOBBY, VIEWING AREA, AND OFFICE*OPTIONAL IN BACK OF HOUSE AREAS WHERE THERE IS ACT (ACOUSTIC CEILING TILE) L6 2X4 BACKLIT LED FLAT PANEL COLOR AND WATTAGE SELECTABLE WHITE FINISH DIMMABLE 0-10V (COLOR TEMP TO BE SET TO 3500K/WATTAGE TO BE SET TO 40 WATTS) ENVISION: LED-BPL-2X4-3M50-5CCT 50 WATTS 120V FOR LOBBY, VIEWING AREA, AND OFFICE. SAME AS THE L-1 FIXTURE BUT A LARGER SIZE 2X4 EX-2 UNIVERSAL MOUNT THERMOPLASTIC EXIT SIGN WITH 2 HEADED EMERGENCY LIGHT 90 MINUTE BATTERY BACK RED LETTERS WHITE FINISH ELITE: ELX-LED-703-R-W 40 WATTS 120V EXIT SIGN FOR BACK OF HOUSE. COLOR OF TEXT DICTATED BY LOCAL CODE. VERIFY WITH YOUR AOR 01 LEGEND NEW PARTITION EXISTING WALL EXISTING WALL WITH NEW FURRING GYPSUM BOARD CEILING ACOUSTIC CEILING TILE N.I.C. EM EM EM EM EM EM EM EM EM EM EM EM EM EM No . Is s u e Da t e SE A L MUNICIPAL APPROVAL STAMP 32 0 E H U N T I N G T O N D R I V E AR C A D I A , C A 9 1 0 0 6 41 2 S . W e l l s S t r e e t 2 n d F l o o r C h i c a g o I L 6 0 6 0 7 P: 3 1 2 9 5 5 0 3 3 4 d x u a r c h . c o m AR C H I T E C T CO N S U L T A N T S CL I E N T PR O J E C T Pr o j e c t N u m b e r : Dr a w n B y : Ap p r o v e d B y : These documents are confidential and shall be in the possession of authorized individuals only. These documents are the exclusive property of DxU architects and shall not be copied or reproduced without written authorization. SHEET TITLE & NUMBER KI D S T R O N G IS S U E F O R P E R M I T 25 - 0 2 2 YP AM © D x U 2 0 2 1 PL O T D A T E : 5/ 1 / 2 0 2 5 9 : 3 2 A M PL O T T E D B Y : YU R I T Z Y P E R E Z CO N D I T I O N A L U S E P E R M I T 20 2 5 / 0 3 / 0 6 ZO N I N G & F I R E C O M M E N T S 20 2 5 / 0 5 / 0 1 1 REFLECTED CEILING PLAN A2-01 01 EXTERIOR ELEVATION - FRONT 3/16" = 1'-0" KID STRONG ADJ. TENANTKID STRONGADJ. TENANT ANGLED FLOOR BREAK 02 EXTERIOR ELEVATION - REAR 3/16" = 1'-0" KID STRONG ADJ. TENANT 8'-5"24'-7" 71'-012" KEYNOTES EXISTING DOOR TO BE ROTATED. REPAIR AS REQUIRED. PROVIDE PANIC BAR IF NOT EXISTING.01 02 03 04 SECURE EXISTING DOORS CLOSED. EXISTING CANOPY TO REMAIN EXISTING SHELL WALL AND STOREFRONT TO REMAIN. PATCH/REPAIR/FINISH AS REQUIRED TO MATCH EXISTING FINISHES. 02 05 EXISTING REAR DOOR TO REMAIN, PROVIDE PANIC BAR IF NOT EXISTING. PROTECT DURING CONSTRUCTION. 03 0404 06 05 01 06 EXISTING SHELL WALL TO REMAIN. 05 KID STRONGADJ. TENANT KidStrong 07 SIGNAGE - CHANNEL LETTERS MOUNTED ON BAND. GC TO COORDINATE INSTALLATION AND PROVIDE TIME CLOCK AND ALL POWER CONNECTIONS. 07 GENERAL NOTES 1.ALL SIGNAGE UNDER SEPARATE PERMIT. 2.G.C. TO VERIFY ALL DIMENSIONS IN FIELD. 3.SCOPE INCLUDES EXISTING TO REMAIN STOREFRONT FOR TENANT SPACE ONLY. No . Is s u e Da t e SE A L MUNICIPAL APPROVAL STAMP 32 0 E H U N T I N G T O N D R I V E AR C A D I A , C A 9 1 0 0 6 41 2 S . W e l l s S t r e e t 2 n d F l o o r C h i c a g o I L 6 0 6 0 7 P: 3 1 2 9 5 5 0 3 3 4 d x u a r c h . c o m AR C H I T E C T CO N S U L T A N T S CL I E N T PR O J E C T Pr o j e c t N u m b e r : Dr a w n B y : Ap p r o v e d B y : These documents are confidential and shall be in the possession of authorized individuals only. These documents are the exclusive property of DxU architects and shall not be copied or reproduced without written authorization. SHEET TITLE & NUMBER KI D S T R O N G IS S U E F O R P E R M I T 25 - 0 2 2 YP AM © D x U 2 0 2 1 PL O T D A T E : 5/ 1 / 2 0 2 5 9 : 3 3 A M PL O T T E D B Y : YU R I T Z Y P E R E Z CO N D I T I O N A L U S E P E R M I T 20 2 5 / 0 3 / 0 6 ZO N I N G & F I R E C O M M E N T S 20 2 5 / 0 5 / 0 1 1 EXTERIOR ELEVATIONS A6-01 1