HomeMy WebLinkAbout2280 ORDINANCE NO. 2280 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF ARCADIA, CALIFORNIA, AMENDING ARTICLE III OF THE ARCADIA MUNICIPAL CODE RELATING TO FIRE REGULATIONS AND ADOPTING BY REFERENCE THE 2010 EDITION OF THE CALIFORNIA FIRE CODE IN ITS ENTIRETY, INCLUDING CHAPTER 1 AND APPENDICES CHAPTER 4, B, C, D, E, F, G, I AND J BASED ON THE 2009 EDITION OF THE INTERNATIONAL FIRE CODE PUBLISHED BY THE INTERNATIONAL CODE COUNCIL THE CITY COUNCIL OF THE CITY OF ARCADIA, CALIFORNIA, DOES ORDAIN AS FOLLOWS: SECTION 1. The City Council finds that the amendments and additions to the California Fire Code herein are supported by Findings of Fact which are attached as Exhibit "A" and incorporated as part of this Ordinance. SECTION 2. Section 3121 of Article III, Chapter 1, Part 2, Division 1 of the Arcadia Municipal Code is hereby amended to read as follows: 3121. CALIFORNIA FIRE CODE ADOPTION. Subject to the exception of the deletions or additions hereinafter set forth, and further subject to the amendments hereinafter specified, there is adopted by reference for the City of Arcadia the 2010 Edition of the California Fire Code, including Chapter 1 and Appendices Chapter 4, B, C, D, E, F, G, I, and J based on the 2009 Edition of the International Fire Code published by the International Code Council, and the foregoing shall constitute the Fire Code of the City of Arcadia. One (1) copy of said codes are on file in the office of the City Clerk for use and examination by the public. 1 SECTION 3. Section 3123 of Article III, Chapter 1, Part 2, Division 3 of the Arcadia Municipal Code is hereby amended to read as follows: 3123. VIOLATIONS. 1. Any person who shall violate any of the provisions of Sections 104, or 105 of Chapter 1 of the Fire Code or who shall build in violation of any detailed statement of specifications or plans submitted and approved under the provisions of this Code or Standards adopted, or any certificate or permit issued thereunder, and from which no appeal has been taken, or who shall fail to comply with such an order as affirmed or modified by the City Council or by a court of competent jurisdiction, with the time fixed herein, shall severally for each and every such violation, be guilty of a misdemeanor or an infraction, punishable pursuant to Section 1200 of the Arcadia Municipal Code. 2. Any person who shall violate any other section of the Fire Code shall be guilty of an infraction, punishable by fine as adopted by City Council Resolution. 3. The imposition of one penalty for any violation shall not excuse the violation or permit it to continue; and all such persons shall be required to correct or remedy such violations or defect in a timely manner as specified by the Fire Chief or his authorized representative. 4. The application of the above penalties shall not be held to prevent the enforced removal of prohibited conditions. SECTION 4. Article III, Chapter 1, Part 2, Division 4 is hereby amended in its entirety to read as follows: 2 3124. AMENDMENTS AND ADDITIONS. The California Fire Code is hereby amended to read as follows: 3124.1. AMENDMENT. Section 510.3 of the California Fire Code is amended to read as follows due to local climatic, geographical, and topographical conditions: 510.3 Emergency responder radio coverage in existing buildings. Existing buildings that do not have approved radio coverage for emergency responders within the building shall be equipped with such coverage according to one of the following: . 1. Wherever an existing wired communication system cannot be repaired or is being replaced, or where not approved in accordance with Section 510.1, Exception 1. 2. Whenever total additions result in an increase of more than 5000 square feet in the total floor area, including mezzanines or additional stories, regardless of ownership. Additions shall be cumulative with each application for building permit from January 1, 2011. 3. Whenever the value of alterations requiring permits exceed $500,000 in valuation. Alteration values shall be cumulative with each application for a building permit from January 1, 2011. 3124.2. AMENDMENT. Section 903.2 of the California Fire Code is amended to read as follows due to local climatic, geographical, and topographical conditions: 903.2. Where required. Approved automatic extinguishing systems shall be installed: 1. In all new buildings regardless of the type of construction or occupancy. EXCEPTIONS: A) Detached Group U occupancies, providing the floor area does not exceed 1000 square feet. B) Pool houses, recreation rooms, and similar accessory R -3 occupancies providing no portion of the exterior wall of the building is more than 150 feet from a public street. 3 C) Other minor buildings and /or occupancies as approved by the Fire Chief. 2. In existing buildings with new occupancies as required by other sections of the Fire Code. 3124.3. AMENDMENT. Section 903.3.1.2 of the California Fire Code is amended to read as follows due to local climatic, geographical, and topographical conditions: 903.3.1.2. NFPA 13R SPRINKLER SYSTEMS. Where allowed in buildings of Group R, up to and including buildings four stories in height, automatic sprinkler systems shall be installed throughout in accordance with NFPA 13R with the following additions: A) Attics shall be fully sprinklered with quick- response intermediate temperature heads. B) Private garages shall be sprinklered and shall have a design density of an Ordinary Hazard Group 1 occupancy with a design area of two (2) heads. Quick - response intermediate temperature commercial type heads shall be used for the garage area. 3124.4. AMENDMENT. Section 903.3.1.3 of the California Fire Code is amended to read as follows due to local climatic, geographical, and topographical conditions: 903.3.1.3. NFPA 13D SPRINKLER SYSTEMS. Where allowed, automatic sprinkler systems installed in one -and two - family dwellings shall be installed throughout in accordance with NFPA 13D with the following additions: A) Attics containing forced air units shall have one or more quick- response intermediate temperature sprinkler heads adjacent to each unit. B) Attached private garages shall be sprinklered and shall have a design density of an Ordinary Hazard Group 1 occupancy with a design area of two (2) heads. Quick- response intermediate temperature commercial type heads shall be used for the garage area. 4 C) Detached private garages over 1000 square feet in total area shall be sprinklered and shall have a design density of an Ordinary Hazard Group 1 occupancy with a design area of 2 heads. Quick- response intermediate temperature commercial type heads shall be used for the garage area. D) Residential structures under 5000 square feet in total area shall be designed for two (2) heads flowing in the residential area. Residential structures over 5000 square feet in total area shall be designed for four (4) heads flowing in the residential area. 3124.5. AMENDMENT. Section 903.6 of the California Fire Code is amended to read as follows due to local climatic, geographical, and topographic conditions: 903.6. EXISTING BUILDINGS. An approved automatic fire sprinkler system shall be installed in existing buildings, including any additions thereto, in the occupancies and buildings as set forth in this section. 1. In all commercial and industrial buildings greater than 5000 square feet in area when enlarged by an addition to the existing structure or as required by the Fire Chief. 2. In all commercial and industrial buildings equal to or less than 5000 square feet in area, when enlarged by an addition to the existing structure, exceeds 5000 square feet or as required by the Fire Chief. 3. In all Group R -1 or R -2 Occupancies when an addition results in additional guestrooms or dwelling units. 4. In all Group R -3 Occupancies greater than 2500 square feet in living area when enlarged by an addition to the living area of the existing structure. EXCEPTIONS: A) Additions of areas that would not require sprinklers such as closets or bathrooms. 5. In all Group R -3 Occupancies equal to or less than 2500 square feet in living area, when enlarged by an addition to the living area of the existing structure, exceeds 2500 square feet in residential area. 5 EXCEPTIONS: A) Additions of areas that would not require sprinklers such as closets or bathrooms. 6. In existing buildings for new occupancies as required by other sections of the Fire Code. 3124.6. AMENDMENT. Section 903.4.2 of the California Fire Code is amended to read as follows due to local topographic conditions: 903.4.2. ALARMS. Approved audible devices shall be connected to every automatic sprinkler system. Such sprinkler water -flow alarm devices shall be activated by water flow equivalent to the flow of a single sprinkler of the smallest orifice size installed in the system. Alarm devices shall be provided on the exterior of the building in an approved location. Where a fire alarm system is installed, actuation of the automatic fire sprinkler system shall actuate the building fire alarm system. Approved audible notification appliances shall be provided in the interior of the building at locations required by the Fire Chief. 3124.7. ADDITION. Sections 504.4, 504.4.1 and 504.4.2 are hereby added to Chapter 5 of the California Fire Code to read as follows due to local climatic conditions: 504.4. Photovoltaic system installation requirements. 504.4.1. Signage. Approved signage shall be provided at the following locations: 1. Direct Current Conduit, Raceways, Enclosures, Cable Assemblies, and Junction Boxes 6 a. Marking should be placed on all interior and exterior DC conduit, raceways, enclosures, and cable assemblies, every 10 feet, at turns and above and /or below penetrations and at all DC combiner and junction boxes. b. Marking should read - "CAUTION: SOLAR CIRCUIT" 2. DC Disconnect a. Signage should read — "PV SYSTEM - DC DISCONNECT" 3. INVERTER: a. Signage should read — "PV SYSTEM — INVERTER — WARNING: ELECTRICAL SHOCKHAZARD" 4. AC DISCONNECT: a. Signage should read — "PV SYSTEM — AC DISCONNECT" 5. Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. 504.4.2. Emergency access pathways. Emergency access pathways shall be provided for photovoltaic system installations as follows: 1. Residential Systems: EXCEPTIONS: Photovoltaic systems on detached garages and /or pool houses. a. Residential Buildings with hip roof layouts: Modules should be located in a manner that provides 3' wide clear access pathway from the eave to the ridge on each roof slope where modules are located. The access pathway should be located at a structurally strong location on the building (such as a bearing wall). b. Residential Buildings with a single ridge: Modules should be located in a manner that provides 3' wide access pathways from the eave to the ridge on each roof slope where modules are located. c. Hips and valleys: Modules should be located no closer than 1.5' to a hip or a valley if modules are to be placed on both sides of a hip or valley. If the modules are to be located on only one side of a hip or valley that is of equal length then the modules may be placed directly adjacent to the hip or valley. 7 d. The modules should be located no higher than 3' below the ridge. 2. Commercial Systems: a. Should be over structural members. b. Centerline axis pathways should be provided in both axes of the roof. Centerline axis pathways should run on structural members or over the next closest structural member nearest to the center lines of the roof. c. Should be straight line not less than 4' clear to skylights and /or ventilation hatches. d. Should be straight line not less than 3' clear to roof standpipes. e. Should provide not less than 3' clear around roof access hatch with a single minimum 4' clear pathway to parapet or roof edge. f. Arrays should be no greater than 150 feet by 150 feet in size measured in either axis. g. Pathway width options between array sections should be either: 1) 8' or greater in width. 2) 4' or greater in width and bordering on existing roof skylights or ventilation hatches. 3) 4' or greater in width and bordering 4' x 8' "venting cutouts" every 20' on alternating sides of the pathway. 3. Ground Mounted Arrays: a. A clear brush area of 10' is required for ground mounted photovoltaic arrays. 3124.8. ADDITION. Section 3308.2 is added to Chapter 33 of the California Fire Code to read as follows due to local climatic conditions: 3308.2. FIREWORKS PROHIBITED. No person shall sell, display for sale, possess, store, or manufacture, use, light, fire, discharge, explode or set off any fire - 8 works, including "Safe and Sane" fireworks anywhere within the City, except as allowed by the Fire Chief. 3124.9. ADDITION [ADMINISTRATIVE]. Section 105.1.4 is added to the California Fire Code to read as follows: When the application for a permit under this section is filed, a non - refundable fee as adopted by City Council Resolution shall be paid for the purpose of recovering the cost of services provided. SECTION 5. The City Clerk shall certify to the adoption of the Ordinance and shall cause a copy of same to be published in the official newspaper of said City within fifteen (15) days after its adoption.. Passed, approved and adopted this 7th day of De cember , 2010. Mayor of the City of Arcadia ATTEST: City Clerk APPROVED AS TO FORM: Stephen P. Deitsch City Attorney 9 STATE OF CALIFORNIA ) COUNTY OF LOS ANGELES ) SS: CITY OF ARCADIA ) I, JAMES H. BARROWS, City Clerk of the City of Arcadia, hereby certifies that the foregoing Ordinance No. 2280 was passed and adopted by the City Council of the City of Arcadia, signed by the Mayor and attested to by the City Clerk at a regular meeting of said Council held on the 7th day of December, 2010 and that said Ordinance was adopted by the following vote, to wit: AYES: Council Member Chandler, Harbicht, Kovacic, Segal and Amundson NOES: None ABSENT: None ./,____ A' ity Clerk of the City of Arcadia 10 % A• Gp . y 1FOk ii Al 1 Iv 21.41%,.-. X1 ATTACHMENT A I�•�ry Ao(utt f. LfOt c ° m�� ty ° t om �`� FINDINGS OF FACT (1 • O f Pursuant to the 2010 Edition of the California Fire Code Preface, the report ` contained herein shall be submitted as the Findings of Fact document with A rcadia regard to Article III of the City of Arcadia Municipal Code, Ordinance No. 2280, as adopted by the City of Arcadia. Under this adopting Ordinance specific amendments have been established, which are more restrictive in nature than those sections adopted by the California Building Standards Code. Fire The amendments to the California Fire Code, 2010 Edition have been Department recognized by the City of Arcadia to address the fire problem(s), concern(s) and future direction(s) by which this City can establish and maintain an environment, which will afford a level of fire and life safety to its citizens and guests. Tony L. Trabbie Fire Chief Under the provisions of California Fire Code Preface, local amendments shall be based on climatic, geographical or topographical conditions. The Findings of Facts contained herein shall address each of these situations and shall present the local situation, which singularly or in combination cause the established amendments to be adopted. Climatic: The City of Arcadia is located in the County of Los Angeles, and is subject to long periods of dry, hot and windy climates, which increase the chance of a fire occurring and predispose the City to large destructive fires. These dry climatic conditions and winds contribute to the rapid spread of even small fires originating in moderate density housing or vegetation. These fires spread very quickly and create a need for increased levels for fire prevention and protection. Geographical: The geographic layout and contours of the City of Arcadia create barriers for accessibility for fire suppression forces. Due to the City's close proximity to major fault lines, there is a significant possibility for multiple fires spreading out of control due to ruptured gas lines and multiple structural collapses. Because of the major earthquake hazard, and due to some older nonconforming buildings, it is necessary during the new construction or building renovation to use the City ordinance to control and minimize conditions hazardous to life and property, which may result from fire, hazardous materials or an explosion. Topographical: The water supply (domestic and fire flow) system within the City is directly affected by the topographical layout of Arcadia. The distribution system consists of high -low pressure and gravity systems zones, which carry the water from various reservoirs and storage tanks to different zones via water pipes. These street mains consist of high - pressure lines and low pressure lines 630 S. Baldwin Avenue Arcadia, CA 91007 (626) 574-5100 (626) 446 -7410 where the pressure and flows are adequate in most of the areas of the city. There are certain areas in the southern portion of the City with static pressures of 40 psi., and in the northern portion as low as 20 psi. This variation of pressure causes major problems to development, as well as fire suppression forces. As a result of the Findings of Fact, which identified the various climatic, geographical, and topographical elements, the requirements established by the City of Arcadia Fire Department within the adopted Ordinance No. 2280 are considered reasonable and necessary modifications to the California Fire Code based upon local conditions. While it is clearly understood that the adoption of such regulations may not prevent the incidents of fire, it is further noted that with the implementation of these various regulations and/or requirements it may serve to reduce the severity and potential loss of life and property. The City of Arcadia Fire Department submits these Findings of Fact and request acceptance of these as defined in the California Fire Code Preface. Prepared and submitted by: Mark Krikorian, Fire Marshal