HomeMy WebLinkAboutMEP-20-0574 j,
City of Arcadia,CA Permit NO. MEP-20-0574
Development Services Department Permit Type:MEP
240 West Huntington Drive,Post Office Box 60021
Arcadia,CA 91066-6021 Work Classification:MEP-Residential
(626)574-5416 Permit Status:Issued
ARCADIA Issue Date:04/16/2020 Expiration:
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
1033 CATALPA RD Arcadia, CA 91007-6021 5776018005
Contacts
YOUNG,HARRY AND CHAYA Owner KYLE GILMORE PLUMBING HVAC R Contractor
1033 CATALPA RD 617 N ALLYN AVE,ONTAIRO,CA 91764
(909)235-8594 883106
Avr
Description:REPLACE EXISTING FAU,ADD NEW A/C,LOCATION Valuation: $ 0.00 Tenant
ON PLAN, VQ Total Sq Feet: 0.00 Plan Check# Plan#
Fees Amount Payments Amount Paid
Compressor 3-5 Ton(3 to 15 hp) $36.35 Total Fees $160.30
Electrical Permit Issuance Fee $47.01 Cash/Receipt#REC-04280-20 $160.30
Furnace or Burner<=100,000 BTU $19.86
Amount Due: $0.00
Mechanical Permit Issuance Fee $47.01
Motors,Generators<1 hp $8.07 '% `/1S (/� //�
Solid Waste Management Fee 2 $1.00 / //�J f..iJ j�'e) ���
Solid Waste Management Fee 2 $1.00 //
n'
Total: $160.30 g'/5 � C�/� ,>
1 ED CALLS FOR INSPECTIONS
COMPU
Request for inspection by telephone at 626-574-5450. Leave a message
requesting the address,timeframe and what inspection item is needed.
This permit/plan review expires by time limitation and becomes null and
void if the work authorized by the permit is not commenced within 180 days
from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 consecutive days.
•
April 16, 2020
Issued By: Date
April 21,2020 Page 1 of 1
AR
0$1.tFO/N.1':
PERMIT/PLAN REVIEW APILICATION
Development Services Department,240 West Huntington Drive,Post Office Box 60021
\ j Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173
City of
Arcadia
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers'
License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the
Signature of Contractor performance of the work for which this permit is issued.
OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section
❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are:
Code.Any city or county which requires a permit to construct,alter,improve, Carrier
demolish,or repair any structure,prior to its issuance,also required the applicant
for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less)
7000)of Division 3 of the Business and Professions Code)or that he or she is
exempt there from and the basis for the alleged exemption. Any violation of 0 I certify that in the performance of the work for which this permit is issued,I shall
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions of Section 3700 of the Labor Code,I shall
❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions.
compensation,will do the work,and the structure is not intended or offered for
sale(Section 7044,Business and Professions Code:The Contractors License Date Signature
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provii1P4,ferA Section 3706 of the Labor Code, interest, and
attorney's fees. . D.
❑I, as owner of the property, am exclusively contracting with licensed L`!d,Jd
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
Date Signature Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for
further information.
•r
Name Title
PRINT NAME
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the above-mentioned property for inspection purposes.
Signature Date
_.„....,
) .10 i •ti,,,,k;c7.
.,. . ._ ...._
\_, t\IN
C.i
, 1 ‘"At
--i M -- . %--
. —..... riet...._ 1
1, •
-
...... ,... ,.._
4,
IV Or
411 - Wa' , • 1
Liii,PLfit , 4.44, cs 0--
t.f> •1....4 -)
____-
,....)
••••••1 mwoomm ......1
fl"'"i".. .- 1•411
b
. ‘,.
.,.: .,
„..,_
. ., ,
(N.
.4710 e•"'' -- -..•••••••••••••ar. - .,.....••=11
It \ ce
_........_ ...._,
, ._.
4
. ,
I /
• ,
t .
I.... ,
1
1
..11. I
AI I 1
.1
....„ i
t' • ` • •
PD
-o -9com 'o
CD m m FD Q"' Q �
Ito 3 ,�I
' I Z • f�
n!
I -1 t i
I _ I
I ,,n
{c>
f(p w m '
i\ 1! '; \ Ii it V O 6
I
\__ii_' _t1 _1_j \--II
I .+ -1 `, o,
1— -r---f � ' i so`v7zI
{ G
\ ' '‘, ' , ; ;.,--; -,- ;
\ ; ,
I I \ II�,
Ir,
,I I I iCD O U)
I I
I . (n
J
John Zurick
To: HARRY YOUNG
Subject: RE: HERS Report for 1033 Catalpa Rd, Arcadia
Attachments: Untitled
Importance: Low
Hello Harry,
Thank you for the HERS approval report.
Please see the attached photos of some of the items that need to be resolved for my approval of your HVAC installation.
1 A minimum of 1" clearance from the fau b-vent to any combustibles at the roof penetration.
2 Make up all R-6 ducting connections per the manufacturer's installation requirements and the Energy Code.
3 The 2' catwalk needs to lead to the working side of the attic fau,then a 30" x 30" working space plywood
platform shall be on the front side of the fau for maintenance.Also non-metallic sheathed electrical wiring
shall not cross over the top of the catwalk or the working space in front of the fau.
4 Remove all restrictions from the R-6 flex ducting and support it with smooth turning radiuses for acceptable
air flow.
5 Insulate all metal duct ty's per the Energy Code.
Please call for re-inspection when the corrections have been made.
Respectfully,
John Zurick
Senior Building Inspector
Development Services Department
240 W. Huntington Drive
Post Office Box 60021
Arcadia, CA 91006-6021
(626) 574-5417 Direct
(626) 574-5416 Main Line
(626) 574-5450 Inspection Request
jzurickaArcadiaCA.gov
"Service, Dedication, Integrity"
From: HARRY YOUNG<youngharry5@gmail.com>
Sent:Wednesday,July 15, 2020 9:23 AM
To:John Zurick<JZURICK@arcadiaca.gov>
Subject: Fwd: HERS Report for 1033 Catalpa Rd,Arcadia
Hi. Attached is the Hers report. Thanks
Harry 714-872-9820
Begin forwarded message:
i
From: HARRY YOUNG<youngharry5@gmail.com>
Date: June 9, 2020 at 9:32:29 AM PDT
To: Jzurick(cr�arcadiaca.gov
Subject: Fwd: HERS Report for 1033 Catalpa Rd, Arcadia
Hi,
Attached is the Hers report for AC unit on 1033 Catalpa, Arcadia.
Thank you
Harry Young
714-872-9820
2