Loading...
HomeMy WebLinkAbout1108 S Baldwin Ave - 2020 - TI - Chef Tony DimSumGENERAL NOTES 1 1. AN APPROVED NUMBER OR ADDRESS MUST BE PROVIDED IN A POSITION THAT WILL BE PLAINLY VISIBLE FROM THE STREET, OR ROAD FRONTING THRE PROPERTY. NUMBERS ARE REQUIRED TO BE A MINIMUM OF 61NCHES IN HEIGHT, 2. SPRINKLER SYSTEM PLANS FOR MODIFICATION, OR FOR NEW SYSTEMS, ARE PERMITTED SEPARATELY BY THE FIRE DEPARTMENT AND MUST BE APPROVED BEFORE WORK BEGINS. SEPARATE SUBMITTAL AND PERMIT. 3. FIRE ALARM PLANS FOR MODIFICATIONS, OR FOR NEW SYSTEMS, ARE PERMITTED SEPARATELY BY THE FIRE DEPARTMENT AND MUST BE APPROVED BEFORE WORK BEGINS. SEPARATE SUBMITTAL AND PERMIT. 4. EXISTING SYSTEM DEVICES MAY ONLY BE RE —USED IF THE INSTALLATION WILL COMPLY WITH CURRENT CODE REQUIREMENTS, AND APPROVED BY LOCAL AUTHORITY. 5. KITCHEN HOOD FIRE PROTECTION SYSTEM PLANS ARE PERMITTED SEPARATELY BY THE CITY AND LA CO. FIRE DEPARTMENT AND MUST BE APPROVED BEFORE WORK BEGINS. SEPARATE SUBMITTAL AND PREMIT. 6. CERTIFICATION OF INSTALLATION —THE INSTALLER SHALL, UPQN COMPLETION OF INSTALLATION AND TESTING , "CERTIFICATE OF COMPLIANCE' TO THE INSPECTORS STATING THAT THE SYSTEM HAS BEEN INSTALLED IN ACCORDANCE WITH THE APPROVED PLANS AND SPECIFICATIONS. 7. EXIT SIGNS AND EMERGENCY ILLUMINATION IS REQUIRED TO COMPLY WITH 2O19 CBC, 8. THE POWER SUPPLY FOR EMERGENCY LIGHTING WILL NORMALLY BE SUPPLIED BY THE PREMISES' ELECTRICAL SUPPLY. IN THE EVENT OF IT'S FAILURE, ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM THE EMERGENCY BACKUP OR BATTERY SYSTEM 9. THE FIRE DEPARTMENT MUST BE CONTACTED A MINIMUM OF 3-5 DAYS IN ADVANCE TO SCHEDULE INSPECTIONS OR TESTING. 10. ALL DECORATIVE MATERIALS AND FURNISHINGS MUST BE MADE FROM NON—FLAMMABLE MATERIAL OR BE TREATED AND MAINTAINED IN A FLAME RETARDANT CONDITION BY A LICENSED APPLICATOR. ALL FINISH MATERIALS SHALL COMPLY WITH 2O19 CBC. 11. ANNUAL PERMITS MAY BE REQUIRED FRON THE FIRE DEPARTMENT AND SHALL BE DETERMINED BEFORE PROJECT COMPLETION. 12. ALL ROOMS USED FOR ASSEMBLY, CLASSROOMS, DINING ROOMS OR SIMILAR ROOMS, WITH AN OCCUPANT LOAD IN EXCESS OF 50 PERSONS MUST HAVE THE ROOM CAPACITY POSTED IN A CONSPICOUS LOCATION. THE SIGN MUST BE DURABLE HAVING A CONTRASTING COLOR FROM THE BACKGROUND TO WHICH IT IS ATTACHED. 13. ALL EXIT DOORS FROM ASSEMBLY OCCUPANCIES SHALL NOT BE PROVIDED WITH A LATCH AND LOCK UNLESS IT IS A PANIC HARDWARE, UNLESS IT IS A MAIN EXIT DOOR FROM THE BUILDING LOCKED WHENEVER IS SIGNBUILOVER STHE DUPORD„THAT STATES, "THIS DOOR IS TO REMAIN 14. ALL FIRE STOPPING SYSTEMS SHALL BE INSTALLED AS DETAILED IN THE INSTALLATION INSTRUCTION OF THE LISTING, AND IN COMPLIANCE WITH 2O19 CBC. FIRE DEPT. REQUIREMENTS �2 1) EXIT DOOR SHALL BE OPENABLE FROM THE INSIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 2) WIDTH AND HEIGHT OF REQUIRED EXIT DOORWAYS TO COMPLY WITH TITLE 24, 2019 CBC. 3) EXITS SHALL BE ILLUMINATED AT ANY TIME THE BUILDING IS OCCUPIED, WITH LIGHT HAVING AN INTENSITY OF NOT LESS THAN ONE FOOT—CANDLE AT FLOOR LEVEL. 4) EXIT SIGN SHALL BE PER CBC 2019. 5) BUILDING ADDRESS NUMBERS TO BE PROVIDED ON THE FRONT OF ALL BUILDINGS AND SHALL BE VISIBLE AND LEGIBLE FROM STREET FRONTING THE PROPERTY. SAID NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. 6) AN APPROVED FIXED FIRE EXTINGUISHERS SYSTEM FOR THE KITCHEN HOOD, DUCTS AND COOKING SURFACES SHALL BE HANDLED BY THE LICENSED FIRE PROTECTON CO. SEPARATE SUBMITTAL AND PERMIT. 7) PROVIDE A "3A40BC" FIRE EXTINGUISHER WITH RECESSED OR SEMI —RECESSED CABINET WITHIN 75 FEET TRAVEL DISTANCE OF ALL POINTS IN THE OCCUPANCY. EXTINGUISHERS SHALL BE MOUNTED IN EASILY ACCESSIBLE LOCATION AT 48" FROM THE TOP OF THE EXTINGUISHERS TO THE FINISHED FLOOR. 8) IN KITCHEN AREA, PROVIDE A "K" TYPE FIRE EXTINGUISHER, MOUNTED AT 48"AFF MAX. TO TOP PROVED A RECESSED PORTION OF WALL TO MOUNT THE FIRE EXTINGUISHER. COORDINATE LOCATION OF THIS FIRE EXTINGUISHER WITH THE PULL STATION FOR THE HOOD SUPPRESSION SYSTEM TO BE LOCATED TOGETHER. 9) INSTALLATION OF EXH. HOOD EXTINGUISHING SYSTEM SHALL BE APPROVED UNDER SEPARATE PERMIT AND SUBMITTED WITHIN 30 DAYS OF ISSUANCE OF BUILDING PERMIT. 10) THE LICENSED FIRE PROTECTION CO. IS RESPONSIBLE FOR THE U.L. APPROVAL SYSTEM NUMBER, THE SUBMISSION U.L. APPROVAL SCHEMATIC DRAWING TO AREA INSPECTION UNIT. 1 1) INTERIOR FINISH SHALL BE PROVIDED IN ACCORDANCE WITH CBC 2019. 12) COMMERCIAL DUMPSTERS OR CONTAINERS WITH AN INDIVIDUAL CAPACITY ON 1.5 CUBIC YARDS OR GREATER SHALL NOT BE STORED OR PLACED WITHIN FIVE FEET OF COMBUSTIBLE WALLS, OPENINGS OR COMBUSTIBLE ROOF EAVE LINES UNLESS AREAS CONTAINING DUMPSTERS ARE PROTECTED BY AN APPROVED SPRINKLER SYSTEM. 13) THE MODIFICATION OF FIRE SPRINKLER SYSTEM (IF REQUIRE) WILL BE SEPARATELY SUBMITTED FOR PLAN CHECK AND PERMIT BY AN LICENSED FIRE PROTECTION CO. 14) EXTEND AND/OR MODIFY SPRINKLER AND LIFE SAFETY SYSTEM AS NEEDED AND APPROVES BY LOCAL AUTHORITY. HEALTH DEPT. REQUIREMENTS 3O 1. All EQUIPMENT MUST BE LISTED BY NATIONAL SANITATION FOUNDATION (NSF) AND MEET APPLICABLE NSF INSTALLATION REQUIREMENT OR EQUIVALENT. ALL EQUIPMENT MUST BE ON SIX—INCH HIGH ROUND, WASHABLE, WATERPROOF LEGS, OR PLACED ON CASTERS AND BE EASILY MOVABLE OR SEALED TO THE FLOOR AND COVED WITH A 3/8—INCH RADIU FOUR —INCH HIGH COVE. 2. ANY EQUIPMENT DISCHARGING LIQUID WASTER SHALL DRAIN TO A FLOOR SINK VIA LEGAL GAP (I.E. THREE COMPARTMENT SINK, FOOD PREPARATION SINK, WALK—IN COOLER, STEAM TABLE, ICE MACHINE, SODA MACHINE, ETC.) 3. FLOOR SINKS SHALL BE INSTALLED FLUSH WITH THE FLOOR SURFACE AND BE LOCATION SO AS TO BE READILY ACCESSIBLE FOR CLEANING AND REPAIR. 4. WITHIN 60 DAYS FROM THE COMMENCEMENT OF OPERATION, THE OWNER OR EMPLOYEE MUST HAVE SUCCESSFULLY PASSED AN APPROVED AND ACCREDITED FOOD CERTIFICATION EXAMINATION. THE FOOD SAFETY CERTIFICATION SHALL BE RETAINED ON FILE AT THE FOOD FACILITY AT ALL TIMES, AND SHALL BE MADE AVAILABLE FOR INSPECTION . THE RESPONSIBILITY OF THE CERTIFIED OWNER OR EMPLOYEE SHALL INCLUDE THE SAFETY OF FOOD PREPARATION AND SERVICE 5. FINAL INSPECTION AND APPROVAL IS REQUIRED PRIOR TO BEGINNING OPERATION. THIS DEPARTMENT REQUIRES AT LEAST FIVE (5) WORKING DAYS NOTICE TO ARRANGE FOR FINIAL INSPECTION. CONSTRUCTION NOTE: 4O 1) ALL CONSTRUCTION WORK SHALL CONFORM WITH THE REQUIRE MEETS OF THE LOCAL BUILDING CODE AND ALL OTHER CODES AND ORDINANCES HAVING JURISDICTION. 2) THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO STARTING WORK, INCLUDING EXACT LOCATION, SIZE, DEPTH AND AVAILABILITY OF ALL UTILITIES CONCERNED. AND ALL CONSTRUCTION WORK MUST BE FOLLOW THE CITY AND HEALTH DEPARTMENT'S APPROVED PLANS. 3) ANY DISCREPANCIES AND / OR OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER AND THE CONTRACTOR AT THAT TIME. ANY CHANGES TO THE APPROVED PLAN, MUST BE BROUGHT TO THE PLAN CHECKERS ATTENTION. 4) GENERAL CONTRACTOR SHALL PROVIDE PROPER BACKING FOR ALL WALL MOUNTED EQUIPMENT AND SHELVING, REGULATIONS. 5) CONTRACTOR ACTIVITY SHALL NOT BEGIN BEFORE 7 A.M. OR CONTINUE LATER THAN 7 P.M. AND 8 A.M. TO 5 P.M. ON SATURDAY. SITE PLAN SCALE: 1 /32" = l'—O" CHEF TONY DIMSUM (TENANT IMPROVEMENT ONLY) 1108 S. BALD WIN AVE. ARCADIA, CA 91007 TRASH ENCLOSURE PROJECT 0 5)1 VICINITY MAP N.T.S East Pasadena Din Tm Funq - if ECW—gpa NiN;eiead m SITE SCOPE OF WORK PREVIOUS RESTAURANT CHANGE OWNER TO BE REMODEL. T.I. WORK CONSISTS OF THE FOLLOWING: CHANGE IN COOKING EQUIPMENT. OWNER: YI DONG GROUP, INC. TEL: (626) 400-8086 ADDRESS: 1108 S. BALDWIN AVE. ARCADIA, CA 91007 DATA: 1) RESTAURANT AREA: 2,617 S.F. REMODEL AREA: 120 S.F. 2) CONSTRUCTION TYPE: V—B (EXISTING SPRINKLER SYSTEM) 3) OCCUPANCY GROUP: A-2 4) STORY: ONE 5) NO ALCOHOL SERVED. 6) EXTERIOR SIGN UNDER SEPARATE PERMIT BY SIGN CO. 7) EXISTING HVAC SYSTEM REMAIN NO CHANGE "ALL HVAC EQUIPMENT IS EXISTING" OCCUPANCY LOAD CALCULATION CBC TABLE 1004.1.2 SECTION AREA OCCUPANCY LOAD KITCHEN AREA 838 S.F. 838 SF/200 = 4.19 SERVICE AREA 70 S.F. 70 SF/200 = 0.35 CUSTOMER AREA 1028 S.F. 1028 SF/15 = 68.5 HALLWAY & RESTROOM etc. 681 S.F. _ TOTAL 2,617 S.F. 73.04 OCCUPANT LOAD SHALL BE 74 PERSONS CODE OF DESIGN 2019 CALIFORNIA BUILDING CODE (CBC) 2019 CALIFORNIA ELECTRICAL CODE (CEC) 2019 CALIFORNIA MECHANICAL CODE (CMC) 2019 CALIFORNIA PLUMBING CODE (CPC) 2019 CALIFORNIA FIRE CODE (CFC) 2019 CALIFORNIA ENERGY CODE (CEES) 2019 CAL. GREEN BUILDING CODE(CGBSC) AND LOCAL GOVERNMENT CODE INDEX COVER SHEET & SITE PLAN aa���r-r•11•L�at�r.T•i-a��a� A-1.1I EXISTING FLOOR & CEILING PLAN A-2 I H.C. DETAILS M-1 M-2 P-1 P-2 MECHANICAL GENERAL NOTES AND DETAILS ROOF PLAN PLUM13ING GENERAL NU I ES AND UE I AILS PLUMBING PLAN dependable !yesign Inc. 615 LAS TUNAS DR. #205 ARCADIA, CA 91007 6 Tel: (626) 388-4919 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Dependable Design Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Dependable Design Inc. �I 7 I;1 X --� �- r` 0 o_ Z O Q U Z W cc G Q o UJ Q U � 0 � Q Z > O � z Z Q I_l_ w o m = W �- U V) 00 0 r- 0 Q U 0 J 0 w 0 ry a Q�OFESS/p ' �Or\�,\ASOIy �! CO 1 Na C/�40169 1 Y ` Kn-22 -ICEI v �F C Al' Date: 1 1/24/2020 Job No: C201 13G Design By: Drawn By: J.A. Scale: AS StIOW ON Z EQUIPVE\ T FIXTURE SCHEDULE ependabie NO QUA DESCRIPTION MARK AND MODEL • ELECTRICAL PLUMBING VOLT RATING LOCATION DESCRIPTION WATER WASTE A.F.F GAS (BTU) e• E 1 3 BOOTH & TABLE CUSTOM-MADE S g n �. E 2 11ot TABLES & CHAIRS CUSTOM-MADE ;. E 3 2 DISPLAY REFREGERATER _ "LEADER" 115 5 AMPS WALL PLUG-IN Lla E 4 1 CASH REGISTER BY OWNER 115 40 W WALL PLUG-IN E 5 1 34" H. FRONT COUNTER (S.S.) • CUSTOM-MADE 615 LAS TUNAS DR. #205 E 6 1 BACK COUNTER CUSTOM-MADE ARCADIA, CA 91007 (E) 7 2 SERVICE TABLE CUSTOM-MADE Tel: (626) 388-4919 E) 8 1 ICE MAKER (WASTE TO F/S) 115 13 AMPS WALL PLUG-IN 1/2 C.W. F/S E 9 1 PREP. SINK (WASTE TO F/S) W/S.S. SPLASHING GUARD (6"H.FROM SIN 5) "EAGLE" 1/2 C.H. F/S 50 -10° designs, arrangement All ideas, d ar ent and w Ions indicated or represented bythis E 10 1 S.S. WORK TABLE "GWS" 100% MECHANICAL MAKE-UP AIR WITH AN * AIR CURTAIN MICRO- drawing are the property of Dependable INTERLOCKING SWITCH WILL BE PROVIDED N) 11 1 DISPLAY CASE "STAR" 115 10 AMPS WALL PLUG-IN 7'-6" 4 7° SWITCH-DOOR-ACTIVATED. Design Inc. and were created for use on 6'-5" 9'-1" 8 -O" 3 HOOD 13' 2' 36"BOOR 10 -0 this specific project. None of these E 12 llot DRY STORAGE WIRE SHELVING (4 TIERS) (24'x4=96' LINEAR FEET) "GSW„ - _ ._--..-.._ -- -- I __ P (--:._In SELF-CLOSE ideas, designs, arrangements or plans E 13 1 EXH. HOOD #1 TYPE "I" 6'-0"X4'-O'w/AUTO FIRE PROTECTION SYSTEM ACCURE" 208 1 HP ROOF J" BOX I I�-1 E 14 1 MAKE-UP AIR "ACCURE 115 3/4 HP ROOF J BOX 1/2 C.W. y ` r_ 32" CLR. may be used by or disclosed to any ( / ) / .-7, -_- __. 2 110 -- } � �\F h ! a Person, firm, or corporation without the E ;5 1 CHINESE WOK RANGE (WASTE TO F/S) "TRUE" TWT-48 AMPSPLUG-IN 1 2 C.W. F/S 220,000 � 5'-0' -~ - f,, k,k rnR (E 6 2 WORKTOP REFRIGERATOR 115 5 WALL RESTROOM (N/F-D li: written permission of Dependable SWITCH-LIGHT & ` Esti X 36 X18 60"x18" Design Inc. (E) 17 2 HAND SINK W/SOAP TOWEL DISP EAGLE" 1/2 C.H. VENTLATION / -ACTIVATED., 0 , g1 " J E) 18 I DISH WASH TABLE (S.S.) "EAGLE' I \o., -n 48 - 45 42 C J - O ! \ o3/ �) STAF X I I WALK-INREST OM 47 - I I ' ® ® COOLER a—a I ,�E) 19 1 DISH WASH MACHINE ( WASTE TO F/S ) CHEMICAL SANITATION 120 3/4 HP WALL PLUG-IN 1 2 C.H. F S (E 20 1 3-COMP SINK W/2-18 DR. BD. ( WASTE TO F/S ) "EAGLE" 3/4 C.H. F/S WOMEN'S' FASE 22 1 S.S. WORK TABLE "EAG E STROaNI— i - - i 36" DOOR43S 41 26 C399� 38t _ _ _ 44 *` ' 8(E) 23 1 3 PAN HOT FOOD WARMER ( WASTE TO F/S ) 'EAGLE GROUP" HT6CB-240 208 10 AMPS ROOF PLUG-IN 30'X48' CLR 00 a 36ki 4��SELF CLOSE x18 60"x1' _ I 32" CLR. 46 � x l(N 24 1 S.S. WORK TABLE "GWS' $ L_ _ J1 ,� WALtl � ., "f, µ (N 25 3 DOUBLE STOCK POT STOVE "IMPERIAL" IMPE-IHPA-2-12 180,000 e 3- 40 (E 26 3 DEEP FRYER W/12"H. S.S. SPLASHING GUARD "FEY MASTER" 110,000 WOMEN SIGN v.i`f- SEL F DOOR �OS _ 34 WALK-IN 00 DETAIL SEE A-2 2x FREEZE' a E 27 1 EXH. HOOD #2 TYPE "I' 24'-0"X4-0'w/AUTO FIRE PROTECTION SYSTEM ACCURE 208 1 HP ROOF "J" BOX 32" CLR. LOCK ROOM P�fTCHEN REMAIN HANGS E 28 2 MAKE-UP AIR "ACCURE" 115 3/4 HP ROOF "J" BOX 1/2 C.W. (EXISTING) 36 r zo E 29 1 CHINESE ® \ "--, �`� 8" (E) 30 1 STEAMER WOK RANGE (WASTE TO F/S) CE VELAND" PGM-200-3 1/2 C.H. F/S 220,000 DETAIL SEETA-2IG� - K' PREP. AREA = 3'-0' 36"x18 60 x1 E 31 1 EMPLOYEE LOCKER WITH 6" MTL. LEGS "GSW" r I -ED + k at> :�, l�' f> � �,`� E 32 1 HAND SINK W/SOAP TOWEL DISP EAGLE - - - 1/2 C.H. DE-TSIGN A 2h�2 E) 33 2 COLD TABLE (SELF-CONTAINED) "TURBO AIR" MST 48 N 115 4.4AMPS ROOF PLUG-IN ® M 1 j (E) 34 1 WALK-IN FREEZER ( WASTE TO F/S ) "GENERAL" #25219 208 1/2 HP WALL PLUG-IN F/S # ► i O _ „ 36" DOOR ,- __'� T -� SELF-CLOSE 29 o COOKING (E) 36 111ot WIRE SHELVINGFOR WALKS INO F S "GENERAL" #25219 208 3/4 HP WALL PLUG-IN F/S Q EN S F/S ¢ ® F MARS MARS-36N 208 2.5 AMP WALL PLUG-IN 26 (E) 37 1 AIR CURTAIN i Q 32" CLR. STROO` 30 28 AREA 025 24 ® 20 /S _ (N) 38 1 STEAMER (WASTE TO F/S ) SINO WOK1 1/2 C.W. F/S 110,000 = t _ 0 „ „ -- N, �� - i- F'-S 19 (E) 39 1 EXH. HOOD #3 TYPE 'I" 8'-0'X4'-0°w/AUTO FIRE PROTECTION SYSTEM ACCURE 208 1 HP ROOF J BOX i ; i ' ' - F/D g� \ (E) 40 1 MAKE-UP AIR "ACCURE" 115 3/4 HP ROOF "J" BOX 1/2 C.W. RESTROOM �44' ow I I I 1/v°� 28 / EO'' °� SWITCH-LIGHT & i \I (E) 41 1 CHINESE B.B.Q. OVEN "GSW" 58,000 VENTLATION CTILE ENTRY SIGN > FAN /I� ( CO, Q " " ,(E) 42 1 CONVECTION OVEN "HOBART" HOBA-HGC-501 44,000 -ACTIVATED. 1ETAIL SEE A-2;�2 ! �j� �/ (400 (E) 43 1 EXH. HOOD #4 TYPE I 4-0'X4-0 w/AUTO FIRE PROTECTION SYSTEM BY CONTRACTOR 208 1 HP ROOF J BOX 1`-^" __ _--5 -1 .___ - -� _I \ \ \ \ 18 (E) 44 1 MAKE-UP AIR "ACCURE" 115 3/4 HP ROOF "J" BOX 1/2 C.W. X /I2 -- 1 M g r_;" _ " r I 'IR 'P - )_ _ __ _ �Al- .e• ► i.a _'fa'II IMMO___ - - _ _ _ - -— - - - n (E) 45 1 2-COMP SINK ( WASTE TO F/S ) \ "GWS" 1/2 C.H. F/S 4'-0" - 8 - __ - - - - 3,_0„ -� / (E) 46 1 MOP SINK W/ MOP HANGER & SHELVING W/ CLEANING EQ. W/BACKFLOW PREVENTION DEVICE 1/2 C.H. (E 47 1 100 GAL. GAS WATER HEATER "RHEEM" 3/4 C.W. 199,000 ) -C3 -O �I `' /48"x18" (E) 48 1 S.S. WORK TABLE "GWS" \ (----- 8 a O ALL EQUIPMENT AND FOOD STORAGE SHELVING MUST MEET "NSF" OR "ANSI" CERTIFICATION. _ x S O (E): EXISTING iy ---- -- -, i' ------ / 1• J LT). (N): NEW o f 0 / \ O < DINING AREA ,,' '� ' ' 3'-10" I--- (EXISTING) © - .r -1 ¢- -----� _— - Ts - - ,. E Q F-1 \ is- SCHEDULEw F/. 30"X4 " CLR. FRONT COUNTER, $ ' �� � 1 - _ - - - - -- - KNEE TOE 36' CLR. SPACE \ 6) c 1 W Q BOON FLOOR BASE WALL CI LI \ G �ENAR <S _ ERR 15 I CLFA SPACE MAX. 34" HIGH CIDETAIL SEE A-2O&® d z 13 c FINISH SCHEDULE NOTE: ;-'44 I F S o - Q w vi w w 1) Wall and ceilings in all areas except dining areas all be durable, III 4 ¢ / �`I / 16 �- `r-� z F- w vi F- smooth, and nonabsorbent, with a light colored light colored is ll w _ - defined as havinga light reflectance value of 70% or greater.), I v c 0 C w - _ ct = 0 9 O �OOKIN z w I • _ Q _J J 2) All counter surface easilncludinable underside durable, finish le m smooth, > AREA " Li— QY requireLLJI ! 1 "z ± w easilycleanable, washable finish. \ _ ® �``^ / m z w 0 00 c9 o z � z z � z �- z stainless steel or NSF approval hick pressure laminate . � � � I � 0 cn 0 = r'' a Q = = Q o z w z 3) Flooring under equipment and at f e base coves shall be cam - �' 1 141 x - p ,i ,_ .� 3 J ¢ J m ° J > z J m letel smooth: floor surfaces which contain slip resistant agents © ' - y ' © o m r M A N E o w co oo w w = w w = w Q w o 0 shalt be restricted to traffic areas only. .a 3'-7" z __ L-� o N p . z = _ z E �- ' z 0 I-- F- a- z d 20 d 4) All equipment shall be either easily movable (i.e., on casters), C 10 9 CO 6 . ( 0 w a �o CO o w I °a- - z o J J4 4 a- J < o 0 °- 0 m U masonry slanduwith mintathree-eghths1einchocoved radius. solid i _ .g � 0 w w c� J z > w �i _ F- > w c(n w GJ w V) 2 v=i Z 5) Floor Smooth Conc. must be Top-set type ceramic coved base. ! _"- III 9 .....-4.. . � -� J __ z J J J W J ` (/1 J -J U D coW J V) z F {- W Z 8 `t H F- UJ Q J (n W F- {- Q J N lLl U Q ✓ (.7.. r1 7X, MATERIALS NOTE: _, _ 0 Q w c� o J z z 0 J o cL 0 0 o CEILING PANELS the ceilingpanels area roved --- ®. I a (3 ~ > E_- a m 1( z . 0 a F- Q J 0 CO 0 < _ 0 1 0 Armstrong#870 Mina board followingL (Mtllminate; nonperforated) a. < w w 0 Q a` Q --I m F= a = 2 cn F-- Q I t� m Q - o - Domtar Gypsum #3270 White vinyl facingpane CUSTOMER AREA Q z w o w Q z vim oz w a>- 0I Q Q L- I Q w x o x U.S.G su 3270 Vinyl rock a 0 5 v 2 0 0 5 vi L 0 o = a. a 2 0 0 = _? _~ _2_ c'l can c� U.S.Gypsumyp 56091 Envirogard with clean room facing -co- --- FLOOR COVERING Tiles --- American Olean, Del Tile, © i CUSTOMER AREA 0 0 0 J 0 0 0 Approved Topset Ceramic coved base --- B & W tile Co. #S-3619T I 'r" 0 i Huntington Pacific (OTW, Inc.) #5-3619T i= SERVICE AREA 0 0 0 0 0 00000 0 Approvaed Sheet vinyl --- Armstrong "Classic Corlon"(86000 Series) 0 i - Q Q I Armstrong "Custom Corlon° (86000 Series) $ I I 1 0 0 KITCHEN/PREP.& LOCK 0 0 0 0 0 0 0 0000 0 0 Tarket "Expression Optima (05800 Series) I - 1 Approvaed Conc. Sealers --- Ameritone 7101, Ague Mix Chioice15 - T� ►- MOP SINK AREA O O O O O O I 0000 O O ALL INTERIOR FINSHES SHALL BE IN COMPLIANCE WITH CH.8 OF 2019 TACTILE EXIT SIG - j RESTROOMS 0 0 0 0000 00000 0 CBC FOR FLAME AND SMOKE INDEX REQUIREMENTS. -a- DETAIL SEE A-2 13 `� TACTILE EXIT SIGN p - DETAIL SEE A-2 13::;[ 40 411. a 1IX3 A ; ® r I I k 1- II !I I II II II i' A A fi� f 36" DOOR I L, �1 I I 8'-10' SELF- OS ALL EXISTING WINDOWS ARE FIXED3l g' SELF-CLOS 0'-,.5" 1J - -- - --- - __ 32"CLR -- - .�__ .-- - -32-CLF�:-- -- - ACCES BLE PANIC HARDW D PAN C HARD ARD DETAILSISEE NTRANCE SIGN DOOR NOTES. DETAL -2 3O DETAIL A-20 A-2 0 4 EXISTING FRONT ENTRY DOOR 3'X6'-8" GLASS DOOR SELF-CLOSING. 32" CLR. C 40169 EXISTING REAR EXIT DOOR 3'-0"X6'-8" DOORPROPOSED FLOOR PLAN 9-30-22 A, , SELF-CLOSING. 32" CLR. ! ..„ PROVIDE ILLUMINATED UPPER/LOWER SCALE: 1/4 =1 -0 q, .. - ip "EXIT" SIGN PER CBC 1011. LIMIT THRESHOLD = 1/2" MAX. DATE: REVISION: LOWER 10" OF THE DOOR SALL BE SMOOTH PLANE SURFACE THE MAIN EXIT SHALL COMPLY WITH TITLE-24 SIGN 1" HIGH LETTERING ON THE ABOVE MAIN EXIT DOOR: "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED." (CBC 1008.1.9.3) DOOR PANIC HARDWARE 5LB. MAX. Date: 11/23/2020 OPENING FORCE (CBC 1008.1.10.) Job No: C201 136 NEW DOOR SHALL BE OPENABLE FROM INSIDE WITHOUT USE OF A KEY Drawn By: JENNY OR ANY SPECIAL KNOWLEDGE OR EFFORT. Scale: I/4"= I'-0" Sheet title: PROPOSED FLOOR PLAN EACH PARKING SPACE RESERVED FOR PERSONS WITH PHYSICAL DISABILITIES SHALL BE IDENTIFIED BY A REFLECTORIZED SIGN PERMANENTLY POSTED IMMEDIATELY ADJACENT TO AND VISIBLE FROM EACH STALL OR SPACE, CONSISTING OF A PROFILE VIEW OF A WHEELCHAIR WITH OCCUPANT IN WHITE ON DARK BLUE BACKGROUND THE SIGN SHALL NOT BE SMALLER THAN 70 SQ. IN. IN AREA AND, WHEN IN A PATH OF TRAVEL, SHALL WHEEL STOP BE POSTED AT A MINIMUM HEIGHT OF 80 IN. FROM THE BOTTOM OF THE SIGN TO THE PARKING SPACE FINISHED GRADE. SIGNS MAY ALSO BE CENTERED ON THE WALL AT THE INTERIOR END OF THE PARKING SPACE AT A MINIMUM HEIGHT OF 60" FROM THE PARKING 70 SQ. INCHES SPACE FINISHED GRADE, GROUND OR SIDEWALK. SPACES COMPLYING WITH 118-502.6, ITEM ACCESSIBILITY SIGN 2 SHALL HAVE AN ADDITIONAL SIGN "VAN -ACCESSIBLE MOUNTED BELOW THE SYMBOL PER CBC. 11 B-502.6 OF ACCESSIBILITY. AN ADDITIONAL SIGN SHALL ALSO BE POSTED, IN A CONSPICUOUS PLACE, AT EACH ENTRANCE TO OFF-STREET PARKING FACILITIES, OR IMMEDIATELY ADJACENT TO AND VISIBLE FROM EACH STALL OR SPACE. THE SIGH SHALL BE NOT LESS THAN 17"x22" IN SIZE WITH LETTERING NOT LESS THAN 1" IN HEIGHT, WHICH CLEARLY AND CONSPICUOUSLY STATES THE FOLLOWING: "UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT OWNER'S EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT 1:50 (2%) MAX SURFACE ARCADIA CITY POLICE DEPT. OR BY TELEPHONING (626) 574-5151" SLOPE IN ANY DIRECTION CONTRACTOR SHALL: * CONTACT LOCAL GOVERNING AUTHORITY FOR APPROPRIATE INFORMATION TO BE ADDED z IN LIEU OF THE BLANK SPACES SHOWN PRIOR TO INSTALLATION OF SIGN. :E 0 PARKING STALLS 00 7 3132„-V-0" z 0 00 ��1-5---5" UNAUTHORIZED........ REFLECTORIZED SIGN CONSTRUCTED OF PORCELAIN ON STEEL, BEADED TEXT, OR EQUAL, DISPLAYING THE FOLLOWING: "UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT OWNERS EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT: ARCADIA CITY POLICE DEPT. OR BY TELEPHONING (626) 574-5151." NOTE: CONTRACTOR OT CONTACT CITY AND HAVE INFORMATION ABOVE PRINTED ON SIGN PRIOR TO INSTALLATION MIN. 1" HGT. WHITE LETTERS AND BLUE BACKGROUND TO BE EQUAL TO COLOR NO. 15090 IN FEDERAL STANDARD 595A. 2"x2" STL. TUBE, CAP & PAINT \ --- TOP OF CONC., PAVING, OR FINISH GRADE. n NOTE: N PROVU ON ' CJO NGY TO PARKING LOT ACCESSIBLE ENTRANCE SIGN - 1 /2" RADIUS REFLECTORIZED SIGN CONSTRUCTED OF PORCELAIN ON STEEL, BEADED TEXT, OR EQUAL, DISPLAYING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY & 1" HEIGHT LETTERING BOTH IN WHITE BLUE BACKGROUND AREA OF SIGN TO BE 70 SO. IN. MIN. VAN ACCESSIBLE SIGN WHERE OCCURS 2"x2" STL. TUBE, CAP & PAINT \-- TOP OF CONC., PAVING, OR FINISH GRADE. io N U12- DIA. CONC. FOOTING NOTE: 1. PROVIDE ONE SIGN, CENTERED AT THE INTERIOR END OF EACH ACCESSIBLE 1 g" PARKING SPACE 2. WHEN WALL MOUNTED, SIGN IS CENTERED ON WALL AT THE INTERIOR END OF THE PARKING SPACE AT A MINIMUM HEIGHT OF 36" FROM THE PARKING SPACE FINISHED GRADE, OR WALKING SURFACE ACCESSIBLE PARKING SIGN SECTION 118-403.5.1 EXC.3 5% � � ,TRUNCATED DOMES IDENTIFICATION SIGN 8.33% MAX. PEDESTRIAN ROUTE (ACCESSIBLE ROUTE) ' STRIPES AT 36 ON CENTER WHITE INTERNATIONAL SYMBOL OF ACCESSIBILITY ON BLUE BACKGROUND NO Wf WHITE BORDER PER � AR K I N G CBC 11 B-502.6.4 THE WORDS "NO PARKING" SHALL 91_0 II MIN. BE PAINTED ON THE GROUND WITH AT TYP. ACCESSIBLE NO LESS THAN 12" HIGH LETTERS, PARKING STALL PAINTED WHITE AND SHALL BE 8'-0" MIN. AT VAN LOCATED TO BE VISIBLE BY TRAFFIC ACCESSIBLE ENFORCEMENT OFFICIALS PARKING STALL FIGURE: SINGLE ACCESSIBLE PARKING STALL IA A 6 I WITHIN THE LOADING & - UNLOADING ACCESSAISLE THE WORDS "NO PARKING IN 12" HEIGHT MIN. WHITE LETTERS PER SECTION 11 B-502.3.3 INTERNATIONAL SYMBOL OF ACCESSIBILITY 36 INCHES(914mm) BY 36 INCHES(914mm) MIN. 11=111.1011 3'32 -W5% = TRUNCATED DOMES MAX IDENTIFICATION SIGN � Z 8.33% MAX. PEDESTRIAN ROUTE (ACCESSIBLE ROUTE) _ SECTION 11 B-403.5.1 EXC.3 WHEEL STOP PER SECTION 11 B-502.7.2 BLUE BORDER HATCHED LINES AT 36 INCHES (914mm) ON CENTER MAX ACCESS AISLE 9'-0" MIN. 8'-0" MIN. AT VAN NOTE: VALTERNATE DIMENSIONS 12'-0" MIN AT VAN —`WHITE LETTERS 12 INCHES PER EXCEPTION SECTION (305 mm) MIN HEIGHT. 11 B-502.2 FOR VAN SPACE. FIGURE: DOUBLE ACCESSIBLE PARKING STALL 3132"=1'-0" REQUIRED CLEAR SPACE 3o"MiN. z i + 18"Mir. F.F. I �a) FAUCET CONTROLS AND OPERATING MECHANISMS ETC. SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL NOT BE NO GREATER THAN 5 LB. SELF CLOSING VALVE FAUCETS MUST REMAIN OPEN FOR AT LEAST 10 SECONDS. TEMPERATURE BALANCED PER CODE. LAVATORY 3/4"=11 .0" PARTITION SMOOTH, HARD, NON -ABSORBENT WALL SURFACE TO 48" A.F.F. - 1�18 MIN. I I 13-1/2 min. PROJECTION z UJ z 1 _ > _ 30"MIN. a v i I -- �` F.F. � � c F.F. REQUIRED CLEAR SPACE SMOOTH HARD NON- _ ABSORBENT FLOOR :2 C SURFACE URINAL FLUSH VALVE CONTROLS SHALL BE OPERABLE WITH ONE HAND, SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST, AND SHALL REQUIRE AN ACTIVATING FORCE NO GREATER THAN 5 LBF. 1 URINAL 318"=1'-Q" 1gg0qq%�� MIN. UCONTRAST TYPKTO GRAPHICS T 12" 1211 0 1 2 WOMENN 1 /4 THICK 1 /12 ,,11CK 1/4-THICK DOOR MOUNTED SIGNAGE (TYP.) DOOR -MOUNTED NOTE: PICTOGRAMS AND/OR LETTERING ARE NOT SIGNAGE REQUIRED ON DOOR -MOUNTED SIGNAGE. WALL MOUNTED SIGNAGE TO BE LOCATED ON LATCH SIDE OF DOOR CLEAR OF DOOR -SWING. MOUNT 48' MIN, ABOVE MOUNT 48' MIN, ABOVE FLOORLINE FROM BASELINE OF BARILLE 60' MAX ABOVE FLOORLINE FROM BASELINE OF HIGHTEST LINE !' OF REISED LETTERS. LETTERING RAISED Z o t/32' 0 LETTERINGF ' 5/8' MIN. TO 2 UPPERCASE CORRESPONDING CHARACTERS GRADE II BRAILLE MEN ALLGENOER WOMEN 11 NAGE SHALL BRAILLE AND NAME 116-703.6.1 SHALL BE SEPARTE FROM PICTURE NOTE: REFER TO NOTE 2.8c FOR ADDITIONAL INFORMATION RESTROOM SIGNAGE ROUTE e= PERMANENT SIGNAGE TO BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. MOUNTING LOCATION MUST ALLOW A Z ', a PERSON TO APPROACH WITHOUT ���� 11��' ENCOUNTERING PROTRUDING OBJECTS o OR STANDING THE DOOR. THE SWING — PATH oO,�S p,0 I -Exi • • • • • CORRESPONDING • • i • GRADE II BRAILLE • • STANDS FOR "MAIN" z �:2 7G 0 Q 41 o RS AND NUMERALS SHALL BE LITERARY BRAILLE CID D 1/32", UPPER CASE, SANS STANDARD DIMENSIONS: TYPE AND SHALL HE ACCOMPANIED DOT DIAMETER GRADE II BRAILLE. RAISED CHARACTERS INTER -DOT SPACING BE AT LEAST 5/8" HIGH, BUT NO HORIZONTAL SEPARATION :R THAN 2". LETTERS & CHARACTERS BETWEEN CELLS CONTRAST WITH THE BACKGROUND VERTICAL SEPARATION BETWEEN CELLS F.F. ,TACTILE EXIT SIGNAGE F. F. 19"MIN. TABLE 19"MIN. ,�.. ' Z � Z 5i i� � m N C C14 (b) COUNTER 30"MIN. CD I z I ( 36"MIN. - \C) MIN. CLEARANCES FOR SEATING & TABLE O7 WHEELCHAIR SEATING SPACE SCALE: 1 4 =1 —0 (a) L CLEAR AT PULL SIDE2��� M) EXTERIOR DOORS � 8" MIN o CLEAR AT C° 32"MIN. INTERIOR CLEAR DOORS z 36 PROVIDE THIS ADDITIONAL SPACE IF DOOR IS EQUIPPED PUSH SIDE WITH BOTH A LATCH AND A CLOSER. 12' NOTE: LANDING SHALL HAVE A M1 . MINIMUM SLOPE OF 1:50 (2%) IN ANY DIRECTION FRONT APPROACH N.T.S. COMPRESSED CARPET FINISH FLOOR EVEN 1/4 1 4" MAX. 6.4mm 2 1 /2 BELOW THRESHOLD 1 12.7mm 1/4 6.4mm BEVELED CHANGE IN LEVEL REGARDLESS OF OCCUPANT LOAD, THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE OF A DOOR. 1. THRESHOLDS. THE FLOOR OR LANDING SHALL BE NOT MORE THAN 1/2" LOWER THAN THE THRESHOLD OF THE DOORWAY. BEVELED: CHANGE IN LEVEL BETWEEN 1/4" HIGH MIN. AND 1/2" HICH MAX. SHALL BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2. (11B-303.3) FLOOR LEVELS AT DOORS (C) NOSTRUCTED HIGH FORWARD REACH 318"=1'-0" :. Z 17-25 432-635000, (A) (B) ELEVATION PLAN ADULT ® TOE CLEARANCE: N.T.S. INTERNATIONAL SYMBOL OF NOTE: ENTRANCE SIGNAGE ACCESSIBILITY BRAILLE SHALL HAVE A WHITE FIGURE ENTRANCE SIGN ON A BLUE BACKGROUND. NOTE: ENTRANCE SIGNS /0 SHALL BE PROVIDED & INSTALLED BY CONTRACTOR. X- E \ O CD CID 0 \ NOTE: PROVIDE A SIGN DISPLAYING THE INTERNATIONAL NOTE: FOR SINGLE DOOR, LOCATE SIGNAGE ON STRIKE SYMBOL OF ACCESSIBILITY AT EVERY PUBLIC ENTRANCE— SIDE OF DOOR. FOR DOUBLE DOORS, LOCATE SIGNAGE PROVIDE SIGNAGE TO INDICATE THE DIRECTION TO ON THE RIGHT. ACCESSIBLE BUILDING ENTRANCES & FACILITIES AS NOTE: USE ADHESIVE FOR ATTACHMENTS WHERE SIGNS REQUIRED. OCCUR AT WINDOWS. SIGNS SHALL BE MADE OF PLASTIC OR METAL. CCESSIBLE ENTRY SIGNAGE DOOR HARDWARE N.T.S. 34"-44" A.F.F. PUSH-PULL LEVER AL � 4"-44" A.F.F. o0 T 0 10" MIN. BOTTOM RAIL 7134"-44" A.F.F. - — OR PROVIDE KICK PLATE 1 PADDLE PANIC HARDWARD RUBBER BUMPER ON CHAIR DOOR HARDWARE. HANDLES, PULLS, LATCHES AND OTHER OPERATING DEVICES ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHINGOR TWISTING OF THE WRIST TO OPERATE. LEVEL -OPERATED MECHANISMS, PUSH -TYPE MECHANISMS, AND U-SHAPED HANDLES ARE ACCEPTABLE DESIGNS. WHEN SLIDING DOORS ARE FULLY OPEN, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. HARDWARE REQUIRED FOR ACCESSIBLE DOOR PASSAGE SHALL BE MOUNTED NO HIGHER THAN 48" (1220mm) ABOVE THE FINISHED FLOOR. DOOR CONSTRUCTION &HARDWARE 60"MIN. CENTERLINE ENTERLINE OF OF FIXTURE FIXTURE FLUSH ACTIVAT R ON WIDEle" SIDE 32" MIN. CLEAR PRIVACY LATCHES PER CBC 11 B-213.2.1. SINGLE -ACCOMMODATION TOILET FACILITY SINGLE OCCUPANCY TOILET 54"MIN. 2" M %X. 42" MIN FEE; 00 I oco i 36"max 24 MIN L SIDE WALL ELEVATION n ELEVATIONS N.T.S. N.T.S. 36" MIN. 24" MIN ALL DISPENSERS TO HIGHEST / OPERABLE i' FLUSH LEVER --/ PART a OPEN SIDE.(WIDE SIDE) REAR WALL ELEVATION N.T.S. gependable gesign Inc. 5. Y 744E `7 615 LAS TUNAS DR. #205 ARCADIA, CA 91007 Tel: (626) 388-4919 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Dependable Design Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Dependable Design Inc. > 0 o_ __J O U z U) r� Q Li 2 .�. Q U w > Q O 0 w z � Q m z LU 00 o i� C 40169 9-30-22 { Date: 1 1 /24/2020 Job No: C20 1 1 36 De51cjn By: Drawn By: J.A. Scale: Sheet title: H.C. DETAILS Sheet N.T.S. N.T.S. GENERAL NOTES 1. ALL WORK SHALL CONFORM TO THE CALIFORNIA PLUMBING CODE LOCAL CODES. INCLUDING INSTALLATION OF ALL REQUIRED CLEANOUTS PER, CPC-2019. 2. CONTRACTORS VERIFY SIZE, DEPTH, LOCATION AND ADEQUACY OF ALL UTILITIES, INCLUDING METER LOCATIONS AND SEWER INVERTS, BEFORE STARTING WORK. 3. ALL PIPING IN FINISHED AREAS SHALL BE CONCEALED WHERE POSSIBLEAND EXPOSED PIPING SHALL BE RUN AS HIGH AS POSSIBLE AND TIGHT TO WALLS. 4. ALL LINES TO BE AWAY FROM BEARING FOOTINGS, OR AS DIRECTED BY STRUCTURAL ENGINEER. 5. INSTALL BACKFLOW PROTECTION DEVICES AS REQUIRED BY LOCAL CODES. 6. INSTALL PRESSURE REDUCING VALVE(S) WITH SHUT-OFF WHERE CITY PRESSURE EXCEEDS 80 PSI. 7. ALL APPLIANCE AND PLUMBING VENTS SHALL BE AT LEAST TEN (10) FEET IN HORIZONTAL DIRECTION OR THREE (3) FEET ABOVE THE OUTSIDE AIR INTAKES FOR HVAC UNITS. 8. SEWER TO BE RUN @ 1/4" SLOPE. CPC (2019) LARGER LINE MAY BE INSTALLED AT A SLOPE OF NOT LESS THAN 1% WHEN FIRST APPROVED BY THE BUILDING DEPARTMENT, MEETING FU RATING OF 2016 CPC. 9. ALL REQUIRED CLEANOUTS SHALL BE INSTALLED AS PER CPC (2019). 10. ALL EXTERIOR HOSE BIBS SHALL BE PROVIDED WITH NON REMOVABLE BACK FLOW PREVENTION DEVICES AND VACUUM BREAKERS. 11. PRESSURE BOOSTER SYSTEM INSTALLED TO ASSURE REQUIRED PRESSURE AT FIXTURE. INSTALL PRVAT DISCHARGE OF PUMP LINE. 12. PROVIDE SHUT OFF VALVES FOR ALL PLUMBING FIXTURES AND GROUPS. 13. PROVIDE ACCESS PANELS FOR ALL GROUPS OF TOILET FIXTURES. 14. PROVIDE TRAP PRIMERS FOR FLOOR DRAINS. 15. USE DIELECTRIC UNIONS TO CONNECT STEEL AND COPPER OR BRASS PIPES & FIXTURES. PLUMBING FIXTURE SCHEDULE PIPE CONNECTION SYMBOL QUANTITY DESCRIPTION CW HW S V TRAP WATER FLOW WATER CLOSET, FLOOR MOUNTED, WHITE VITREOUS CHINA, 17" RIM HEIGHT SIPHON JET ELONGATED BOWL, CLOSE -COUPLED FLUSH TANK WC-1 3 @ 1.28 GPF BY AMERICAN STD. 2168.100. 3/4" - 4" 2" INT 1.28 GPF SEAT: OLSONITE #95, OPEN FRONT, LESS COVER. (2.5 FU) (4 FU) 1.28 GALLONS/FLUSH TANK. LAVATORY, COUNTER TOP, WHITE VITREOUS CHINA, FRONT OVERFLOW, UNDER COUNTER, BY AMERICAN STD. 9482.000, 4" CENTER FAUCET LL-11 3 HOLES. 0.5 GPM 1/2" 1/2" 2" 1 1/2" 1 1/2" FAUCET: SENSOR OPERATED ELECTRONIC FAUCET FOR HOT/COLD (1 FU) (t FU) 0.5 GPF WATER, BY SLOAN. OPTIMA ETF-600-B-2-P WITH PLUG-IN TRANSFORMER AND ETF-460-A GRID STRAINER. URINAL (HANDICAPPED) UU-11 1 A/S "ALLBROOK"6540.017 WHITE VITREOUS CHINA 0.5 GPF WALL HUNG 3/4" - 2" 1 1/2" 1 1/2" 0.25 GPF SIPHON JET URINAL w/FLUSHING RIM, FITTING: SLOAN ROYAL 180 FLOOR DRAIN, CAST IRON BODY, FLASHING COLLAR 6" ROUND NICKEL - 2 i 1/2 2 FD-1 2 BRONZE STRAINER, W/ TRAP PRIMER CONNECTION. BY J.R. SMITH. FIG. (2 FU) 2005YO2A-H-PO50 WITH 2" PIPE OUTLET. FLOOR DRAIN, CAST IRON BODY, FLASHING COLLAR 6" ROUND NICKEL - - 2 1 i/2" 2 FD-1 1 BRONZE STRAINER, W/ TRAP PRIMER CONNECTION. BY J.R. SMITH. FIG. (2 FU) 2005YO2A-H-PO50 WITH 2" PIPE OUTLET. FLOOR SINK, CAST IRON FLANGED WITH ACID RESISTANT COATED INSIDE, - 3" 1 1/2:' 2" FS-1 3 NICKEL BRONZE RIM, SEDIMENT BUCKET, HALF GRATE, 12 1/2" SQUARE, (2 FU) BY J.R. SMITH FIG. 3151YO2-12 WITH 3" PIPE OUTLET FLOOR SINK, CAST IRON FLANGED WITH ACID RESISTANT COATED INSIDE, - 2" 1 1/2" 2" FSFS=2 2 NICKEL BRONZE RIM, SEDIMENT BUCKET, HALF GRATE, 12 1/2" SQUARE, (1 FU) BY J.R. SMITH FIG. 3151Y02-12 WITH 2" PIPE OUTLET MOP SINK, FLOOR MOUNTED, 24"x24" MOLDED STONE WITH 3/4" 3/4" 3" 2" 2" i.2 GPF MINIMUM 10" HIGH SIDES. STAINLESS STEEL DRAIN BODY MS-1 1 INTERNALLY CAST, BY FIAT, MODEL #MSB-2424. (3 FU) (3 FU) FAUCET: CHICAGO FAUCET, MODEL #897 WITH INTEGRAL STOPS IN SHANKS, WALL BRACE, HOSE THREADS, RAIL HOOK, VACUUM BREAKER, ROUGH BRASS FINISH, WITH 3 FEET RUBBER HOSE. HS 2 A/S "FIAT RIM SINK" 7020.207 END OUTLET. FLAT RIM. SINGLE BOWL, 1/2" 1 /2" 2" 1 1 /2" 2" 0.5 GPF COUNTERTOP SINK, ACID RESISTING SNAMELED CAST IRON. DIMENSION: 18"X12"X5 1/2" FITTING: 8344.111 FAUCET w/TOP BRACE, TOP & VACUUM, (1 FU) BREAKER. PROVIDE 1/2" HW AND CW AT ROUGH -IN HEIGHT 14" A.F.F. 8" OC. 3/4" 3/4" 3" 2" PS 2 PROVIDE BV'S AND EXTEND (2 FU) (2 FU) 1.0 GPF COPPER PIPING TO FAUCET. CONNECT 2" WASTE LINE FROM EACH COMPARTMENT SEPARATELY AND DISCHARGE INTO FLOOR SINK WITH AIR GAP. 2CS 1 FURNISHED BY OWNER 1/2" 1/2 (22FU) 1 1 /2 2 0.5 GPF 3CS-1 t FURNISHED BY OWNER 3/4" 3/4" 3" 2" 2" 1.8 GPF (3 FU) (3 FU) PLUMBING LEGEND SYMBOL ABBREVIATION DESCRIPTION • ®•• •� �' ■IDm i o r r' ® ID INDIRECT DRAIN ABOVE GRADE ..a GW _ _ GW GREASE WASTE BELOW GRADE -- -- -S S SANITARY SEWER ABOVE GRADE M ' _ m ® S •• ® ® r S SANITARY SEWER BELOW GRADE - - - - - - V- - - - - - - V SANITARY VENT - SCW SCW SOFTENED COLD WATER CW DOMESTIC COLD WATER - - FCW FCW FILTERED COLD WATER - - HWS DOMESTIC HOT WATER SUPPLY - - - HWR DOMESTIC HOT WATER RETURN .d FCO FLOOR CLEANOUT WCO WALL CLEANOUT SOV SHUT OFF VALVE POC POINT OF CONNECTION O VTR VENT THROUGH ROOF CD CD CONDENSATE DRAIN �..._..-.. _..- G-..--..-..-- -- G NATURAL GAS WC-1 PLUMBING FIXTURE DESIGNATION O1 CONSTRUCTION NOTE R.H. ROUGH -IN HEIGHT A.F.F. ABOVE FINISHED FLOOR G.P.F. GALLON PER FLUSH A.P. ACCESS PANEL G.C. GAS COCK PIPE MATERIAL SCHEDULE SERVICE PIPE FITTINGS LOCATION ABOVE GRADE WASTE & CAST IRON NO HUB CAST IRON NO HUB BELOW GRADE VENT OR ABS OR ABS ABS ONLY FOR BELOW GRADE STORM DRAIN CAST IRON NO HUB CAST IRON NO HUB ABOVE GRADE BELOW GRADE HOT AND COLD COPPER TYPE "L" HARD DRAWN WROUGHT COPPER ABOVE GRADE WATER COLD COPPER TYPEL WROUGHT COPPER BELOW GRADE WATER INDIRECT WASTE COPPER M DRAWNTYPE WROUGHT COOPER ABOVE GRADE CONDENSATE DRAIN BLACK STEEL BLACK STEEL ABOVE GRADE GAS SCHEDULE 40 MALLEABLE IRON EXISTING WATER HEATER: GLASS -LINED, TANK -TYPE COMMERCIAL GAS WATER HEATER SHALL HAVE 100 GALLONS STORAGE CAPACITY 120,000 BTU/HR GAS INPUT, 80 % THERMAL EFFICIENCY @ RECOVERY RATED OF 105 GPH AT 100 TEMPERATURE RISE. WATER HEATER SHALL HAVE A MAXIMUM WORKING PRESSURE OF 150 PSI. COMPLETE WITH ASME TEMP & PRESSURE RELIEF VALVE. BY "BRADFORD WHITE", MODEL: UCG-80H-125-3NA PROVIDE ROUND SECURED NICKEL BRONZE ADJUSTABLE TOP WITH "CO" CAST IN COVER. PROVIDE CLEANOUT TOP WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET 2" VENT IN WALL THREE COMPARTMENT SINK MARKER, RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS). PROVIDE PLASTIC PLUG IN CAST IRON BODY. CLEAN THE TOP OF EXPOSED FCO AFTER INSTALLATION. MEMBRANE CLAM FLOOR SLAB ON GRADE VAS REQUIRED FOR SAME SI4f AS SEWER DEPTH OF SEWER .►�- UP TO 4 MAXIMUM, 2"CO ` 1-1/2' 1-1/2" ` HUB AND SPIGOT LONG SWEEP ELBOW AT CAST IRON PIPE END OR TURN OF RUN. BELOW FLOOR--`_ ` 2" SANITARY OR STORM COMBINATION WYE AND EIGHTH BEND IN RUN. _ 2 FS-1 SEWER LINE ENTER TOP OF PIPE. F.F. 1-1/2"AIR GA F.F.DIRECTION �'- <- OF FLOW = 2 TRAP PRIMER INLET E 3 • 50G GREASE TRAP � LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD OF PIPE GREATER THAN 45 DEGREES, AT 50 INTERVALS 3" WASTE TO MAIN SEWER LINE CONDITIONS OR MEET LOCAL CODE REQUIREMENTS. USE TYPE L ON STRAIGHT RUNS, AND WHERE SHOWN ON PLANS. COPPER TUBING FOR INDIRECT WASTE PIPE, FITINGS AND PROVIDE BACKFILL PER ARCHITECTURAL SPECIFICATIONS. CONNECTORS. LOCATE CLEANOUTS WHERE THERE IS 18" CLEAR AROUND. CONSULT LOCAL CODES FOR OTHER FCO REQUIREMENTS. 3 COMPARTMENT SINK NOT TO SCALE 1 FLOOR CLEANOUT NOT TO SCALE C2). PROVIDE AN INDIVIDUAL VENT ON ALL FLOOR DRAINS. INSTALL VENT IN PARTITION OR CHASE WHERE SHOWN ON PLAN. HORIZONTAL VENT BELOW FLOOR IS NOT PERMITTED. IF FLOOR DRAIN/SINK IS MORE THAN 5' ON A 2" WASTE OR 6' ON A 3" WASTE FROM THE PARTITION, PROVIDE A TRAP AND WASTE LINE TWO PIPE SIZES LARGER THAN THE DRAIN/SINK DRILL HOLE IN OUTLET, WITH A REDUCER ON THE TRAP INLET, AND VENT WITHIN 15 FEET. SIDE OF COOLER OTHER VENTING METHODS MAY BE USED IF APPROVED BY LOCAL CODE. AND PROVIDE CONCRETE FLOOR SILICONE SEAL AROUND PIPE .. - a. PENETRATION. 3/4 " DX COIL REDUCING TRAP MEMBRANE CLAMP- ING COLLAR AND PROVIDE TRAP CO - COORDINATE SEEPAGE PAN. AT BOTTOM OF 0 ROUTING OF MAXIMUM TAILPIECE RISER AND DIS- PROVIDE CLEANOUT DRAIN WITH LENGTH IS 2 FEET. CHARGE INTO IN TURNS AND ENDS SHELVING IN MAXIMUM 15' WHERE ENLARGED WASTE SLOPE WASTE AT FLOOR DRAIN OF PIPE. WALK-IN COOLER OR FLOOR SINK LINE IS USED AS A TWO PERCENT. WITH AIR GAP MAKE CONNECTION COMBINATION WASTE OF TWICE PIPE TO COOLER AND VENT SYSTEM. DIAMETER. PROVIDE TRAP PRIMER IF RE- QUIRED BY LOCAL AUTHORITIES. MAXIMUM 5' ON 2" FLOOR or WALK-IN FREEZER OTHERWISE DEEP -SEAL P-TRAP. WASTE OR 6' ON 3". LOCATE FLOOR DRAIN/SINK WHERE SHOWN ON DIMENSIONED ARCHITEC- SEE FLOOR PLAN FOR FLOOR SINK LOCATION. TRRAL PLAN. IF FLOOR STRUCTURE INTERFERES WITH FLOOR SINK, MOVE SIDEWAYS IF POSSIBLE, OTHERWISE MOVE BACK. ALWAYS LOCATE WHERE EASILY ACCESSIBLE, BUT NOT IN FOOT TRAFFIC. IF SITUATION INSTALL PIPE AS HIGH AS POSSIBLE, ANCHOR TO WALL OF COQL,�R IS FLOOR SLAB ON GRADE, PROVIDE BACKFILL PER SPECIFICATIONS. WITH SUPPORTS AT MAXIMUM SIX FOOT CENTERS. USE TYPE M IF CONCRETE FLOOR IS NOT EXISTING, SET DRAIN IN PLACE AND POUR HARD COPPER TUBE AND FITTINGS WITH LEAD-FREE SOLDER AROUND IT. IF CONCRETE FLOOR IS EXISTING, SAW CUT OR CORE DRILL JOINTS. SLOPE HORIZONTAL PIPE AT MINIMUM TWO PERCENT. IT. SET DRAIN BODY IN PLACE AND POUR AROUND IT. RECESS TOP OF REFER TO LOCAL CODE FOR INDIRECT DRAIN REQUIREMENTS. FLOOR SINKS 1/2" BELOW FLOOR SURFACE AND SLOPE FLOOR TO IT. DO NOT RECESS TOP OF FLOOR DRAINS. IF SITUATION IS FLOOR NOT ON GRADE, REFER TO "FLOOR PENETRATION" DETAIL FOR VENTS. FLOOR DRAIN/ SINK NOT TO SCALE 3 WALK-IN BOX CONDENS.DRAIN NOT TO SCALE MIN. 12" FROM ANY VERTICAL SURFACE. MIN. LOFT FROM, OR MIN. 3FT ABV ANY BLDG OUTSIDE AIR INTAKE. PER IPC, 3/4' H.W. TO SYSTEM (SET ® 140F) G} -� 3/4" C.W. TO HEATER rn 3/4' 2" THERMAL EXPANSION TANK, BY I, -mot' THERM-X-TROL, MODEL ST-12. SUPPORT TANK FROM STRUCTURAL LEAD SLEEVE EMBED MEMBER 4" FLANGE 6" MIN. G 4" AROUND").BUILT-UP ROOF 3/4 5' FLUE VENT UP OFFSET IN CEILING SPACE AND THRU ROOF, SEE DETAIL 16/P-6 PLYWOOD ROOF SHEATHING SLEEVE FLANGE SET IN THERMOMETER_- DOWNDRAFT DIVERTER PLASTIC CEMENT AND NAILED @3"O.C. � � _,. _LINE SIZE P&T RELIEF VALVE VENT PIPE, SEE PLAN FOR SIZES STRAP WATER HEATER TO WALL WITH 1 1/2', 18 GA VENT NOT TO SCALE PIPE THROUGH R 0 E DETAIL 5 STEEL STRAP ANCHOR TO BLDG STUDS WITH ER LAG SCREWS. STRAP 0 UPPER 1/3 AND LOWER OF TANK 1/3 D WATER HEATER 3/4' DRAIN TO MOP SINK STUD WALL 1/2" BALL VALVE CW PIPE c ON WALL �v TRAP PRIMER SECURE TO STUDS - --- 3/8" NUT & BOLT WITH WASHER (TYP) PROVIDE WALL ACCESS CMV WALL - -- GAS PRESSURE REGULATOR UNION - G 1/2" CWD SEAL WATERTIGHT o-k DRAIN HOSE 8188 FLR.DR. FIN. FLOOR GAS COCK DIRT LEG MINIMUM 6" HIGH MOUNTING PLATFORM, FLEXIBLE CONNECTOR - BY G.C. TP q1/2" 1/2" BELOW CW TO TRAP CONNECT FLOOR NOTE: 1. WATER HEATER PROVIDE T&P VALVE TO OUTSIDE OF THE BUILDING. 2. WATER HEATER VENT HAS TO EXTEND 1'-0' ABOVE PARAPET WALL AS REQ'D 3. ALL VENT PIPES SHALL RUN MIN. 10'4 AWAY FROM ALL INTAKE AIR MACHINE OR RESOURCE. TRAP PRIMER DETAIL NOT TO SCALE 6 WATER HEATER M T C . DETAIL NOT TO SCALE 7 gependable esig n Inc. 615 LAS TUNAS DR. #205 ARCADIA, CA 91007 Tel: (626) 388-4919 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Dependable Design Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Dependable Design Inc. .-. r- O O 0Y) 0 U �Q LIJ Q 2 LU U Q I0 w Q Ci 0 z zLJL LJLJ Q m Q z Vi W 00 O z O H Q U O J 0 w 3 O IY- 0- Date: 1 1 /23/2020 Job No: C201 13G Design By: Drawn By: J.A. Scale: 1 /4"= 1'-0" Sheet title: PLUMBING NOTES � DETAILS Sheet �i Fl (E)WATER HEATER — WC 2.5FU +-0--- (E) WC 2.5FU 1/2"CW (2FU)� (E) "' too 1FU (EXISTING) 1-1/2 " CW BOVE CEILING (24.5FU) P.O.C. 1/2"CW (1 FU) r (E) L- ( WC /4 CW UP TFE) -U 41 2.5FU DN. S.O.V. (E) DOUBLE STOCK POT STOVE (E)STEAMER (E) B.B.Q. OVEN (E)DEEP FR' DN. —MS 2-C-Sw -r— as GAS — 2 (E) E)PFU FU S . O.V Y 1+-1/2"CW (2FU) 2"CW (2FU) L 1/2"HW ,FU 3/4"CW (4FU) 3/4"CW (11 FU)�, HS (E) EXISTING NO CHANGE' COLDMOT WATER & GAS P SCALE: 1 / LAN 4"=l'-O" CHINESE WOK RANGE (E) (EYWOOK — 1FU TP 3CS (E) 3FU CD1 [if I I 4"CW (3FU) (Do I I- t111-7----1l/2 "HIN-1 jLS ICE(E) 1FU 1'FMU (E) 1/2"CW '(1 FU -0 1r11/2"CW (1FU) 3/4"CW (3FU) 3/4"CW (3FU) 1/2"HW t-1/2"CW (2FU) ' (E) 2FU FS WC ---• WC 0% � ----- v ----------2Fu 2CS - 4FU I\FUi 2FL/ 4FU 0- 0- r7 4 2"(2FU) 3', 4FU , I 4"S(4FU) LMS I 4`3(4FU) 3 . Fld:- I y A I 4"S(47FU) 4"S(39FU) J J 0- 2% SLOPE - L.O j--) )2% SLOPE 2% SLOPE -k 1FU L, i T L -I o L 1 S(29FU) 3"S(26FU) o- 3"S(26FU) CD I Cn r <D a_ (.4-3"S(26FU) C) L�1 YW( 6FU) FS 4"S(8FU) IFS 7 2FU IFU U-1 0- - 3E 3"(8FU) 2FU z I --- G.T. 10, 3"(9FU) 2'S(2FU) 3"(1 3FU) "I"(1 3FU/ SLOPE 2"(2FU) 3"(11 FU) 3"(11 FU) FD 14FT 4"S(8FU) SLOPE � C.Oir ;Op� - - L 2FU 4"S(5FU) 2-'(21`U�l 2"(2FU) 31!(7FU) L-1 Q WC 0- 2"(2FU) a - CD 1 FU4�/ 1 A V) V) ------------------- FS FS 2FU 2FU 3 (7FU) Cl- i 2"W(2FU)--1 'S 2"(1 FU) I V) I C) J A 2% SLOPEIN - - - - - - - - - - - - - LN-� 3"(4FU) �--u-� 2FU -S :2FU 2"(2FU) : 2"(2FU) C. FS Ld 2FU 2"(2FU) C( PS 2FU WASTENENT PLAN SCALE: 1/4"=1'-0" NOTE: TO STREET PUBLIC SEWER WAATERAL CONNECTION. CONTRACTOR TO FIELD VERIFY THE EXACT POINT OF CONNECTION. APO 1464, 1*1 "14p, UP ,---zuependable !yesign Inc., 615 LAS TUNAS DR. #205 ARCADIA, CA 91007 Tel: (626) 388-4919 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Dependable Design Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Dependable Design Inc. r- 0 0 z 0 C) z W W 2 C) W 0 z 0 < Z L. Liu < z M C) ui 00 0 0 0 0 C) 0 ry Date: 1 1/23/2020 Job No: C20 I I 3G Drawn By: JENNY Scale: 1/4"= 1'-0" PLUMBING FLOOR PLAN GENERAL NOTES 1. ALL MECHANICAL WORK SHALL COMPLY WITH LOCAL APPLICABLE CODE AND CALIFORNA MECHANICAL CODE. 2. ROOF OPENINGS & PLATFORMS TO BE CURBED AND LEVEL, 6" MINIMUM HEIGHT, FLASHED AND CAPPED WITH SHEET METAL. A/C CONTRACTOR TO COORDINATE REQUIRED SIZES AND LOCATIONS WITH GENERAL CONTRACTOR. 3. A/C UNIT ON GROUND OR ROOF TO BE CURBED AND LEVELLED. 4. CONTRACTOR SHALL INSTALL ALL DUCTWORKS TO SUIT THE STRUCTURAL CONDITION. PROVIDE ALL NECESSARY OFFSETS AS REQUIRED. VERIFY WITH ARCHITECTRRAL, STRUCTURAL, ELECTRICAL AND PLUMBING DRAWINGS. 5. EXPOSED DUCTWORK AND PLENUMS TO BE KEPT TO A MINIMUM AND WATERPROOFED. SEAMS TO BE CAULKED WITH SEALING MASTIC BEFORE CLOSING, AND THEN COVERED WITH SECO ALUMINUM PLAS-T-COTE ROOF COATING OR EQUAL SEALING COMPOUND. EXPOSED DUCTWORK AND PLENUMS TO BE LINED INTERNALLY WITH 1" THICK 3-LB DENSITY DUCTLINER. 6. DUCT INSULATION SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF UNIFORM MECHANICAL CODE. INSULATE ALL SUPPLY AND RETURN AIR DUCTS WITH 2" THICK FIBERGLASS BATT INSULATION WITH VAPOR BARRIER FOR DUCT IN ATTIC AND 1" THICK FOR DUCT IN CEILING SPACE. 7. DUCT CONSTRUCTION SEALANT: PROVIDE MASTIC OR TAPE DUCT JOINT SEALANT. 8. DUCTWORK SHALL BE CONSTRUCTED, ERECTED AND TESTED IN ACCORDANCE WITH THE LATEST EDITION OF UNIFORM MECHANICAL CODE CHAPTER 6. 9. ALL DUCTWORK IN STUDWALLS TO BE ISOLATED WITH 1 /4" FELT IN THE DUCT SUPPORTS AND WHERE IT MAKES CONTACT WITH THE BUILDING CONSTRUCTION. INSTALL ONE DUCT ONLY IN EACH STUD SPACE. 10. ALL DUCT DIMENSIONS ARE CLEAR INSIDE. ALL DUCTS SHALL BE FIRMLY SUPPORTED OR HUNG AND NEATLY ALIGNED AND INSTALLED. SPACE HANGERS AS REQUIRED TO SUPPORT THE DUCTS WITHOUT SAGGING AS REQUIRED BY THE BUILDING FRAMEWORK, AND AS REQUIRED BY OTHER INTERFERENCE. LOCATION AND SPACING OF HANGERS AND SUPPORTS SHALL BE COORDINATED BY THE CONTRACTOR. FURNISH AND INSTALL NECESSARY SUPPORTING MATERIAL AND ADDITIONAL STRUCTURAL MEMBERS. SEAL OPEN SPACE BETWEEN DUCTS & WALL COORDINATE DUCTWORK WITH THE LIGHTING FIXTURES, CEILING SUPPORT SYSTEM, AND ACCESS DOORS ETC. 11. CONTRACTOR TO CHECK ARCHITECTURAL REFLECTED CEILING PLAN FOR CEILING DIFFUSER, RETURN AIR REGISTER & CEILING EQUIPMENT ETC. 12. ALL EXTERIOR LOUVERS AND DOOR LOUVERS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR. TIMER, TIME CLOCK & CONDUIT BY ELECTRICAL CONTRACTOR. 13. A/C CONTRACTOR SHALL INSTALL NEW CEILING DIFFUSERS & GRILLES AS NOTED ON PLANS. ALL CEILING DIFFUSERS SHALL BE METAL-AIRE 7000 SERIES PERFORATED OR APPROVED EQUAL. 14. INSTALL MANUAL BALANCING DAMPERS IN ALL BRANCH DUCT RUNS TO INDIVIDUAL DIFFUSERS AND AS REQUIRED TO CONTROL AIRFLOW FOR SYSTEM BALANCING. 15. INSTALL ACOUSTIC LINING IN DUCTWORK FOR 10 FEET ON EACH SIDE OF FAN (SUPPLY AND RETURN). 16. PROVIDE BACKDRAFT DAMPERS AND BIRDSCREENS ON EACH DUCT FROM INTERIOR SPACES TO THE OUTSIDE UNLESS PROHIBITED BY CODE. 17. PROVIDE ACESS PANELS FOR ALL EQUIPMENT CONCEALLED IN ACCESSIBLE SPACES. COORDINATE SIZE AND LOCATION WITH ARCHITECT. 18. CONTRACTOR TO INSTALL APPROVED AUTOMATIC FIRE DAMPERS IN ALL DUCT, DIFFUSERS, GRILLS, ETC. WHERE PENETRATING RATED WALLS, FLOORS, AND CEILING ASSEMBLIES. IN FIRE RATED CORRIDOR SHALL INSTALL COMBINATION FIRE AND SMOKE DAMPER AS REQUIRED BY CALIFONIA BUILDING CODE. 19. ALL CONDENSATE DRAINS SHALL BE TRAPPED AND PIPED TO THE APPROVED RECEPTOR. DRAIN SHALL SLOPE AT NOT LESS THAN 1/8" PER FOOT (1%). 20. ALL A/C CONDENSATE LINES TO BE INSTALLED BY PLUMBING CONTRACTOR. REFER TO MECHANICAL DRAWINGS FOR LOCATION OF CONDENSATE LINES. 21. ALL MECHANICAL EQUIPMENT SHALL BE LABELED TO THE SPACE SERVED. 22, A 120-VOLT RECEPTACLE SHALL BE LOCATED WITHIN 25 FEET OF THE EQUIPMENT FOR SERVICE AND MAINTENANCE PURPOSES. 23. EXHAUST OUTLETS SHALL TERMINATE IN ACCORDANCE WITH THE REQUIREMENTS OF UMC CHAPTER 6. AND 10'-0" ABOVE GRADE. 24. OUTSIDE AIR INTAKE SHALL BE 10'-0" AWAY OR 3'-0" BELOW ANY APPLIANCE VENT OUTLET OR EXHAUST FAN DISCHARGE OR PLUMBING. 25. FILTERS ON RETURN AIR PLENUM SHALL BE FARR 30/30 OR EQUAL 26. CONTRACTOR SHALL PROVIDE VIBRATION ISOLATION DEVICE FOR ALL MECHANICAL EQUIPMENTS AS ACOUSTIC CONTROL. 27. CONTRACTOR SHALL INSTALL THE EQUIPMENT OR SYSTEM PER MANUFACTURER'S INSTALLATION RECOMMENDATION. CONSULT WITH MANUFACTURING COMPANY IF NECESSARY. 28. ALL THERMOSTATS SHALL BE INSTALLED APPROXIMATELY 4 FT ABOVE FINISHED FLOOR. VERIFY LOCATION WITH ARCHITECT. 29. TEST & BALANCE ALL SYSTEMS ACCORDING TO CFM INDICATED ON PLANS. 30. ALL MECHANICAL EQUIPMENT SHALL BE BRACED OR ANCHORED TO RESIST A HORIZONTAL FORCE IN ANY DIRECTION AS FOLLOWS : * FIXED EQUIPMENT ON GRADE 22% OF OPERATING WEIGHT * FIXED EQUIPMENT ON STRUCTURE 33% OF OPERATING WEIGHT * FOR FLEXIBILITY MOUNTED EQUIPMENT USE 2 TIMES THE ABOVE VALUES, FOR * SIMULTANEOUS VERTICAL FORCES - USE 1 /3 TIMES THE HORIZONTAL FORCE. 31. MATERIALS EXPOSED WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME -SPREAD INTHAN 50 WHEN TESTED IN ACCORDANCE WITH CBC STANDARD. DEX OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED RATING OF NOT MORE 32. FLEXIBLE DUCT SHALL BE USED FOR TAKE -OFF AND LIMITED TO 6'-0". LEGEND SYMBOL - DESCRIPTION (L) - LINED DUCT - SIZE INDICATED IS SHEET METAL DIMENSION UTR - UP THRU ROOF DTR - DOWN THRU ROOF NIC - NOT IN THIS CONTRACT P.O.C. - POINT OF CONNECTION W/ - WITH W/O - WITH OUT G.C. - GENERAL CONTRACTOR P.C. - PLUMBING CONTRACTOR E.C. - ELECTRICAL CONTRACTOR M.C. - MECHANICAL CONTRACTOR CFM - CUBIC FEET PER MINUTE S.A. - SUPPLY AIR R.A. - RETURN AIR E.A. - EXHAUST AIR T.X. - TOILET EXHAUST KRHX - KITCHEN RANGE HOOD EXHAUST OSA - OUTSIDE AIR fd - DIAMETER ROUND DUCT O - THERMOSTAT F.D. - FIRE DAMPER Q.B.D. - QUADRANT BALANCING DAMPER B.D.D. - BACKDRAFT DAMPER M.V.D. - MANUAL VOLUME DAMPER C.D. - CEILING DIFFUSER C.R. - CEILING REGISTER E.P. - EXTENDED PANEL R.A.G. - RETURN AIR GRILLE E.G. - EXHAUST GRILLE T.T.B. - TRIM FLANGE TO FIT T-BAR GRID D/L - DOOR LOUVER U/C - UNDERCUT DOOR W.M.S. - WIRE MESH SCREEN CFM CUBIC FEET PER MINUTE OSA OUTSIDE (STANDARD) AIR M.V.D. MANUAL VOLUME DAMPER WM"M FLEX DUCT ® CEILING DIFFUSER CEILING REGISTER ---ISWG SIDEWALL GRILLE O THERMOSTAT N.I.C. NOT IN THIS CONTRACT SD DUCT MOUNTED SMOKE DETECTOR ROOF EQUIPMENT ROOF PARAP' CEILING HOOD ENTRANCE BUILDING SECTION N.T.S. ALL ROOFTOP MECHANICAL EQUIPMENT SHALL BE PLACED BEHIND A PERMANENT PARAPET WALL AND BE COMPLETELLY RESTRICTED FROM ALL GROUND LEVEL VIEWS. IF, AT THE GROUND LEVEL CAN SEE THE ROOF MECH. EQUIPMENT, PROVIDE SCREEN, AND THE COLOR PAINT SHALL BE MATCH TO THE EXISTING BUILDING. MAX. SCOOP LONGTH=3H POINT OF EXH. DISCHARGE 40" HIGH ABOVE THE ROOF BOTTOM HORIZONTAL DISCHARGE IN DIRECTKION OF PREVAILING WIND. OUTLET: 10'-0" FROM ADJACENT PROPERTY LINE OR AIR INTAKE OPENING AND 10'-0" ABOVE THE ADJOINING GRACE LEVEL. ADJACENT BLDGS \\-- OR PARTS BLDGS \ _z REMOVABLE GREASE CONTAINER O 3M FIRE RATED (FIRE RATED TO COMPLY WITH - BUILDING CODE REQUIREMENT) 1 HR. FIRE CONSTRUCTION JOIST JOIST 18,-i CEILING LINE (2) LAYERS OF 5/8" TYPE "X" GYP. BOARD =T PARKING LOT --300 FT.-- --- - REMOVABLE COVER WITHOUT USE OF TOOLS AND THE DOOR SHALL HAVE APPROVED NONCOMBUSTIBLE GASKET MATERIAL UP WARD DISCHARGE 16 GAGE GALV. WELDED ANGLE IRON SUPPORT ALL WELDED EXISTING ROOF JOIWIST 1 14"x10" DUCT CL UT WITH i FITTING HINGED DOD OF STEEL CONSTRUCTION TO M TCH DUCT CEILING LI E 6"MIN. < -- S.S. WALL COVERINGS MIN. ALL OPEN SIDE (BACK AND BOTH SIDES) COOKING EQUIPMENT 6' - HOOD HANGER SUPPORT TO WOOD JOIST 4'-0" X 6'-0" N. FLOOR REMOVABLE COVER WITHOUT USE OF TOOLS AND THE DOOR SHALL HAVE APPRO D NONCOMBUSTIBLE GASKET MATERIAL ANGLE IRON SUPPORT ALL WELDED PROVIDE SCREEN RAIN CAP (MIN 26 U.S. GAGE GALVANIZED COUNTER FLASHING) DUCT ENCLOSURE SHALL BE VENTED TO EXTERIOR THROUGH WEATHER PROTECTED OPENING r� 3M ALL AROUND DUCT (FIRE RATED TO COMPLY WITH BUILDING CODE REQUIREMENT) 1 HR. FIRE CONSTRUCTION 6" MAX. 3" MIN. 5/8" DRY WALL TYPE"X" METAL WALL FLASHING 6 16 GAGE GALV. DUCT WELDED 1 " PITCH PER FOOT METAL MOTOR COVER 10-0" MIN. z_ N ROOF DECK 1 IIMW4� EXISTING JOIST 16 GAGE GALV. DUCT W LDED 14"x10" DUCT CLEANOUT WITH TI FITTING HINGED DOOR OF STEEL CONSTR�ITION TO MATCH DUCT JEFIlAL I-___; EXISTING 1 1 /4" X 1 1 /4" ANGLE IRON EACH LEG (2) 2 1 /2" X 3/8" WOOD SCREW TO ANCHORED W/PLASTER ROOF CEMENT SEAL AIR DIFFUSER \_ 18" WIDE METAL SHEET WHEN HOOD IS LESS THAN 18" If BELOW CEILING EXTEND FIRE RATED CEILING 18" BEYOUND HOOD HOOD LESS THAN 12" FROM CEILING MUST BE FLASHED SOLID. FIRE DEPT. APPROVAL SHALL BE REQUIRED ON O FIRE PROTECTION SYSTEM FOR EXH. HOOD & DUCT `t GREASE FILTER BAFFLE TYPE NFRA 96 SEE NOTE #9 COOKING 6" MIN. ALL OPEN SIDE EQUIPMEN FIN. FLOOR EVAP. COOLER !Yependable UP esign Inc. 615 LAS TUNAS DR. #205 ARCADIA, CA 91007 Tel: (626) 388-4919 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Dependable Design Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Dependable Design Inc. .-W . O O z rn O U LLJ Q 0 LJ _ U 17�1 .�^=' 0 Q 0� 0- O > Q z <( 9 Q m � cri `--� GD O z O Q U O J I- U Lv O Of n FASTEN �I 26 GA. GIL DUCT OR APPROVAL TYPE AIR FLEX DUCT _ 1 " 26 GA. GL. STRAP SUPPORT TO JOIST Date: 1 1 /27/2020 Job No: C201 13G Drawn By: JENNY Scale: 1/4"= I'-0" Sheet title: EXISTING HOOD DETAIL ELEVATION OF EXH. DUCT SHAFT NO SCALE ® SECTION OF EXH. HOOD, BLOWER & MADE-UP AIR NO SCALE 100% MECHANICAL MAKE-UP AIR WITH AN INTERLOCKING SWITCH WILL BE PROVIDED 8'-0" #3 HOODgependable 100% MECHANICAL MAKE-UP AIR WITH AN INTERLOCKING SWITCH WILL BE PROVIDED AL i 8'-0" #3 HOOD zo AIR VELOCITY:1829 FPM I EXIT esI n Inc. _ _ J .,.o- a 11 " ...., � � _._ � F g w.rt�i�lu��ir.:1�..f � WOK RANGE EXH. DUCT 9 X14 C CHINESE1111, II AIR VELOCITY:1829 FPM • 0 1 - EXH. DUCT 14"X18" 615 LAS TUNAS DR. #205 I d 1 ____ _ 10_0" ARCADIA, CA 91007 •CONVECTION OVEN El 00 = -� Tel: (626) 388-4919 • -; MA I I All ideas, designs, arrangement and 4 - i - Ilk r - -�- - plans indicated or re resented bythis . - I o M A P • `' L - t _ © Designgl ceand were the erty of createdOfoendeble on 1 DEEP FRYER '. -, _ Ak -- -- _..- this specific project. None of these I i 1 I o 4 ideas, designs, arrangements or plans i CHINESE B.B.Q. OVEN •tmay be used by or disclosed to any �. 8STEAMER person, firm, or corporation without the written permission of Dependable Design Inc. DOUBLE STOCK POT STOVE DEEP FRYER S.S. WORK TABLE STEAMER CHINESE WOK RANGE DOUBLE STOCK POT STOVE EF _ MA . .re „,, 4 i L ELI I -Qs R�� \i/iiIiB IMIIIIIIEIIIII Z -U' #2 MUD © 100% MECHANICAL MAKE-UP AIR WITH AN INTERLOCKING SWITCH WILL BE PROVIDED L 100% MECHANICAL MAKE--' AIR WITH AN INTERLOCKING SWITC .'LL. BE PROVIDED ROOF EQUIP 1EN I SCHEDULE UNDER HOOD EQUIPMENT ;� 24 0" #2HOOD NO. DESCRIPTION SCALE: 1/4" = 1'-O" AIR VELOCITY:1798, FP EXH. DUCT 16"X24" MA MAKE-UP AIR "FRIGIKING" EVAPORATIVE AIR COOLER, MODEL FS 450 (OR EQUAI) v UNIT SHALL DELIVERY 2400 CFM, @ 0.5" SP., 3/4 HP., FAN MOTOR (EXISTING) ELECTRICAL: 115V-10 -60 HZ, UNIT APPROX. WEIGHT: 480 LBS AIR VELOCITY:1798 FPM Qo EXH DUCT 12"X1611 Lu . KITCHEN HOOD EXH. FAN. "LAU" SERIES BLOWER, MODEL FGP 18-13A (OR EQUAI) GE\ E�AE \OTES ® UNIT SHALL DELIVERY 2400 CFM, @ 0.5 SP., 1-1/2 HP., FAN MOTOR 1) FIRE DEPT. APPROVAL SHALL BE REQUIRED ON 0FIRE PROTECTION SYSTEM FOR GREASE HOODS AND DUCTS o Q (EXISTING) ELECTRICAL: 208V-10 -60 HZ, UNIT APPROX. WEIGHT: 115 LBS AS REQUIRED BY SECTION 510.0 OF THE 2019 CMC D ca J AND AS REQUIRED BY THE FIRE CODE. - N MA MAKE-UP AIR "FRIGIKING" EVAPORATIVE AIR COOLER, MODEL FS 450 (OR EQUAI) 2) ALL HOODS REQUIRE A FIRE EXTINGUISHING SYSTEM AND Mir o © UNIT SHALL DELIVERY 9600 CFM, @ 0.5" SP., 3/4 HP., FAN MOTOR CLEANABLE FILTERS APPROVED BY FIRE DEPT. Z rn ELECTRICAL: 115V-10 -60 HZ, UNIT APPROX. WEIGHT: 480 LBS 3) GREASE HOOD EXHAUST FAN AND MAKE-UP AIR UNITS <_ (EXISTING) m- ___:', ._ _ Q SHALL BE ELECTRICALLY INTERLOCKED. r v W U RIBLOWER, MODEL FGP 18-13A (OR EQUAI 4) DUCT ENCLOSURE SHALL BE VENTED TO EXTERIOR � i Z-° - KITCHEN HOOD EXH. FAN. "LAU" SERIES ) THROUGH WEATHER PROTECTED OPENING. Oz o- Ll.l Q 0 ® UNIT SHALL DELIVERY 9600 CFM, @ 0.5 SP., 1-1/2 HP., FAN MOTOR o, © 208V-10 -60APPROX. WEIGHT: 115 LBS 5) ADD NOTE ON DRAW "G:" AUTOMATIC EXTINGVISHING SYSTEM' \ ELECTRICAL: HZ, UNIT FOR DEEP FRYER. INSTALLATION SHALL BE SUBMITTED IN CD 0 (EXISTING) Q LLJ TRIPLICATE FOR APPROVAL TO THE ENGINEERING UNIT > FIRE DEPT. 0 > MA MAKE-UP AIR "FRIGIKING" EVAPORATIVE AIR COOLER, MODEL FS 450 (OR EQUAI) 6) PROVIDE POWER AND WATER FOR EVAPORATIVE COOLER ( °� • UNIT SHALL DELIVERY 3200 CFM, @ 0.5" SP., 3/4 HP., FAN MOTOR ON ROOF (MAKE-UP AIR.) `-�' Q • (EXISTING) ELECTRICAL: 115V-10 -60 HZ, UNIT APPROX. WEIGHT: 480 LBS 7) FIRE PROTECTIVE SYSTEM & MAKE-UP AIR WHERE REQUIRED "'" BY OTHERS. h" Li- Q KITCHEN HOOD EXH. FAN. "LAU" SERIES BLOWER, MODEL FGP 18-13A (OR EQUAI) 8) BUILDING, ADJACENT PROPERTY LINE, AIR INTAKES OF 10'-0" i- EXHAUST TERMINATION 10'-0" MIN. FROM ADJACENT Mr MA coAAUNIT SHALL DELIVERY 3200 CFM, @ 0.5 SP., 1-1/2 HP., FAN MOTOR ABOVE ADJOINING GRADE. W Uj © ELECTRICAL: 208V-10 -60 HZ, UNIT APPROX. WEIGHT: 115 LBS 9) EXHAUST HOOD TO HAVE 18" ALKL AROUND CLEARANCE (EXISTING) FROM COMBUSTIBLES OR 3" MIN. FROM PROTECTED O MAKE-UP AIR "FRIGIKING" EVAPORATIVE AIR COOLER, MODEL FS 450 (OR EQUAI) COMBUSTIBLES. MA 10) CONTRACTOR TO PROVIDE PERMANENT ACCESS TO ROOF. • 4 UNIT SHALL DELIVERY 1600 CFM, @ 0.6" SP., 3/4 HP., FAN MOTOR ELECTRICAL: 115V-10 -60 HZ, UNIT APPROX. WEIGHT: 480 LBS 11) EXHAUST HOOD DUCT PENETRATION CAN NOT AFFECT THE 1IX3 IIX3 (EXISTING) STRUCTURAL INTEGRITY OF THE ROOF. 12) EXHAUST HOOD MATERIAL MIN. 22 GAGE STEEL. KITCHEN HOOD EXH. FAN. "LAU" SERIES BLOWER, MODEL FGP 18-13A (OR EQUAI) 13) CONTRACTOR SHALL VERIFY WITH EQUIPMENT'S p Ak UNIT SHALL DELIVERY 1600 CFM, @ 0.5 SP., 1-1/2 HP., FAN MOTOR CONTRACTOR FOR THE LOCATION OF EQUIPMENT'S ROOF PLAN \ a o 4 ELECTRICAL: 208V-10 -60 HZ, UNIT APPROX. WEIGHT: 115 LBS PLUMBING BEFORE ANY WORK WILL BE DONE. (EXISTING) 14) ALL WORK MUST COMPLY WITH UMC. SCALE: 1/4"=1'-0" qlr o J I- 0 W (EXISTING) er (EXISTING) fie (EXISTING) ® (EXISTING) oGt o 4 Establishment Name: CHEF TONY DIMSUM Establishment Name: CHEF TONY DIMSUM Establishment Name: CHEF TONY DIMSUM Establishment Name: CHEF TONY DIMSUM Job Address: 1108 S. BALDWIN AVE. ARCADIA, CA 91007 Job Address: 1108 S. BALDWIN AVE. ARCADIA, CA 91007 Job Address: 1108 S. BALDWIN AVE. ARCADIA, CA 91007 Job Address: 1108 S. BALDWIN AVE. ARCADIA, CA 91007 - Provide the following information concerning mechanical exhaust - Provide the following information concerning mechanical exhaust - Provide the following information concerning mechanical exhaust - Provide the following information concerning mechanical exhaust and hood design (3 sets required): and hood designrequired):sets(3 and hood design (3 sets required): and hood design (3 sets required): y - One set of data sheets for each hood system. - One set of data sheets for each hood system. - One set of data sheets for each hood system. - One set of data sheets for each hood system. I i '. I a 1. Size of hood: 6'-0"X4'-0" (TYPE I HOOD) 1. Size of hood: 24'-0"X4'-0" (TYPE I HOOD) 1. Size of hood: 8'-0"X4 1,'-0" (TYPE I HOOD) 1. Size of hood: 4-0 X41 ,1-0 (TYPE I HOOD) LI r- , , 2. CFM: 6.0 X 4.0 X 100 = 2400 CFM 2. CFM: 24.0 X 4.0 X 100 = 9600 CFM 2. CFM: 8.0 X 4.0 X 100 = 3200 CFM 2. CFM: 4.0 X 4.0 X 100 = 1600 CFM ;-- .) , 12.0 X 4.0 X 100 = 4800 CFM (2) DATE: REVISION: 3. Size of duct: 12"X16" (1798 FPM) for EACH DUCT 3. Size of duct: (2) 16"X24" (1798 FPM) for EACH DUCT 3. Size of duct: 14"X18" (1829 FPM) for EACH DUCT 3. Size of duct: 9"X14" (1829 FPM) for EACH DUCT 4. Number of grease filters: 6 4. Number of grease filters: 14 4. Number of grease filters: 9 4. Number of grease filters: 2 5. Size and type of grease filters: 20"X20" = 2.25 s.f 5. Size and type of grease filters: 20"X20" = 2.25 s.f 5. Size and type of grease filters: 20"X20" = 2.25 s.f 5. Size and type of grease filters: 20"X20" = 2.25 s.f 6. Rating of each filter. (CFM or FPM): 800 CFM EACH FOR FILTER 6. Rating of each filter. (CFM or FPM): 686 CFM EACH FOR FILTER 6. Rating of each filter. (CFM or FPM): 356 CFM EACH FOR FILTER 6. Rating of each filter. (CFM or FPM): 800 CFM EACH FOR FILTER 7. Make-up air (CFM): 2400 CFM 7. Make-up air (CFM): 9600 CFM 7. Make-up air (CFM): 3200 CFM 7. Make-up air (CFM): 1600 CFM Date: 1 1/27/2020 (100% make-up air required to be electrically interconnected (100% make-up air required to be electrically interconnected (100% make-up air required to be electrically interconnected (100% make-up air required to be electrically interconnected to exhaust system). to exhaust system). to exhaust system). to exhaust system). Job No: C201 13E. 8. Elevated drawing of hood and cooking equipment shown on 8. Elevated drawing of hood and cooking equipment shown on 8. Elevated drawing of hood and cooking equipment shown on 8. Elevated drawing of hood and cooking equipment shown on Drawn By: JENNY this sheet of plans. this sheet of plans. this sheet of plans. this sheet of plans. I/4"= I '-O" Scale: - Flashing shall extend from hood to floor covering. - Flashing shall extend from hood to floor covering. - Flashing shall extend from hood to floor covering. - Flashing shall extend from hood to floor covering. Sheet title: - Wall surfaces within 18" of all cooking equipment shall be - Wall surfaces within 18" of all cooking equipment shall be - Wall surfaces within 18" of all cooking equipment shall be - Wall surfaces within 18" of all cooking equipment shall be flashed. flashed. flashed. flashed. EXISTING ROOF PLAN 9. COOKING EQUIPMENT: CHINESE WOK RANGE 9. COOKING EQUIPMENT: DOUBLE STOCK POT STOVE x3 9. COOKING EQUIPMENT: CHINESE B.B.Q. OVEN 9. COOKING EQUIPMENT: CONVECTION OVEN CHINESE WOK RANGE DEEP FRYER S.S. WORK TABLE STEAMER DEEP FRYER x2 STEAMER IN 11111 GENERAL NOTES 1. AN APPROVED NUMBER OR ADDRESS MUST BE PROVIDED IN A POSITION THAT WILL BE PLAINLY VISIBLE FROM THE STREET, OR ROAD FRONTING THRE PROPERTY. NUMBERS ARE REQUIRED TO BE A MINIMUM OF 61NCHES IN HEIGHT, 2. SPRINKLER SYSTEM PLANS FOR MODIFICATION, OR FOR NEW SYSTEMS, ARE PERMITTED SEPARATELY BY THE FIRE DEPARTMENT AND MUST BE APPROVED BEFORE WORK BEGINS. SEPARATE SUBMITTAL AND PERMIT. 3. FIRE ALARM PLANS FOR MODIFICATIONS, OR FOR NEW SYSTEMS, ARE PERMITTED SEPARATELY BY THE FIRE DEPARTMENT AND MUST BE APPROVED BEFORE WORK BEGINS. SEPARATE SUBMITTAL AND PERMIT. 4. EXISTING SYSTEM DEVICES MAY ONLY BE RE —USED IF THE INSTALLATION WILL COMPLY WITH CURRENT CODE REQUIREMENTS, AND APPROVED BY LOCAL AUTHORITY. 5. KITCHEN HOOD FIRE PROTECTION SYSTEM PLANS ARE PERMITTED SEPARATELY BY THE CITY AND LA CO. FIRE DEPARTMENT AND MUST BE APPROVED BEFORE WORK BEGINS. SEPARATE SUBMITTAL AND PREMIT. 6 CERTIFICATION 0 INSTALLATION TIOjFTFRSHALL , COMPLETION OF INSTALLATION AND TESTING 'CERTIFICATE OCOMPLANCETO THE INSPECTORS STATING THAT THE SYSTEM HAS BEEN INSTALLED IN ACCORDANCE WITH THE APPROVED PLANS AND SPECIFICATIONS. 7. EXIT SIGNS AND EMERGENCY ILLUMINATION IS REQUIRED TO COMPLY WITH 2O19 CBC, 8. THE POWER SUPPLY FOR EMERGENCY LIGHTING WILL NORMALLY BE SUPPLIED BY THE PREMISES' ELECTRICAL SUPPLY. IN THE EVENT OF IT'S FAILURE, ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM THE EMERGENCY BACKUP OR BATTERY SYSTEM 9. THE FIRE DEPARTMENT MUST BE CONTACTED A MINIMUM OF 3-5 DAYS IN ADVANCE TO SCHEDULE INSPECTIONS OR TESTING. 10. ALL DECORATIVE MATERIALS AND FURNISHINGS MUST BE MADE FROM NON—FLAMMABLE MATERIAL OR BE TREATED AND MAINTAINED IN A FLAME RETARDANT CONDITION BY A LICENSED APPLICATOR. ALL FINISH MATERIALS SHALL COMPLY WITH 2O19 CBC. 11. ANNUAL PERMITS MAY BE REQUIRED FRON THE FIRE DEPARTMENT AND SHALL BE DETERMINED BEFORE PROJECT COMPLETION. 12. ALL ROOMS USED FOR ASSEMBLY, CLASSROOMS, DINING ROOMS OR SIMILAR ROOMS, WITH AN OCCUPANT LOAD IN EXCESS OF 50 PERSONS MUST HAVE THE ROOM CAPACITY POSTED IN A CONSPICOUS LOCATION. THE SIGN MUST BE DURABLE HAVING A CONTRASTING COLOR FROM THE BACKGROUND TO WHICH IT IS ATTACHED. 13. ALL EXIT DOORS FROM ASSEMBLY OCCUPANCIES SHALL NOT BE PROVIDED WITH A LATCH AND LOCK UNLESS IT IS A PANIC HARDWARE, UNLESS IT IS A MAIN EXIT DOOR FROM THE BUILDING AND THERE IS A SIGN OVER THE DOOR ' THAT STATES "THIS DOOR IS TO REMAIN UNLOCKED WHENEVER THE BUILDING IS OCCUPIED 14. ALL FIRE STOPPING SYSTEMS SHALL BE INSTALLED AS DETAILED IN THE INSTALLATION INSTRUCTION OF THE LISTING, AND IN COMPLIANCE WITH 2O19 CBC. FIRE DEPT. REQUIREMENTS <2 1) EXIT DOOR SHALL BE OPENABLE FROM THE INSIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 2) WIDTH AND HEIGHT OF REQUIRED EXIT DOORWAYS TO COMPLY WITH TITLE 24, 2019 CBC. 3) EXITS SHALL BE ILLUMINATED AT ANY TIME THE BUILDING IS OCCUPIED, WITH LIGHT HAVING AN INTENSITY OF NOT LESS THAN ONE FOOT—CANDLE AT FLOOR LEVEL. 4) EXIT SIGN SHALL BE PER CBC 2019. 5) BUILDING ADDRESS NUMBERS TO BE PROVIDED ON THE FRONT OF ALL BUILDINGS AND SHALL BE VISIBLE AND LEGIBLE FROM STREET FRONTING THE PROPERTY. SAID NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. 6) AN APPROVED FIXED FIRE EXTINGUISHERS SYSTEM FOR THE KITCHEN HOOD, DUCTS AND COOKING SURFACES SHALL BE HANDLED BY THE LICENSED FIRE PROTECTON CO. SEPARATE SUBMITTAL AND PERMIT. 7) PROVIDE A "3A40BC" FIRE EXTINGUISHER WITH RECESSED OR SEMI —RECESSED CABINET WITHIN 75 FEET TRAVEL DISTANCE OF ALL POINTS IN THE OCCUPANCY. EXTINGUISHERS SHALL BE MOUNTED IN EASILY ACCESSIBLE LOCATION AT 48" FROM THE TOP OF THE EXTINGUISHERS TO THE FINISHED FLOOR. 8) IN KITCHEN AREA, PROVIDE A "K" TYPE FIRE EXTINGUISHER, MOUNTED AT 48"AFF MAX. TO TOP PROVED A RECESSED PORTION OF WALL TO MOUNT THE FIRE EXTINGUISHER. COORDINATE LOCATION OF THIS FIRE EXTINGUISHER WITH THE PULL STATION FOR THE HOOD SUPPRESSION SYSTEM TO BE LOCATED TOGETHER. 9) INSTALLATION OF EXH. HOOD EXTINGUISHING SYSTEM SHALL BE APPROVED UNDER SEPARATE PERMIT AND SUBMITTED WITHIN 30 DAYS OF ISSUANCE OF BUILDING PERMIT. 10) THE LICENSED FIRE PROTECTION CO. IS RESPONSIBLE FOR THE U.L. APPROVAL SYSTEM NUMBER, THE SUBMISSION U.L. APPROVAL SCHEMATIC DRAWING TO AREA INSPECTION UNIT. 1 1) INTERIOR FINISH SHALL BE PROVIDED IN ACCORDANCE WITH CBC 2019. 12) COMMERCIAL DUMPSTERS OR CONTAINERS WITH AN INDIVIDUAL CAPACITY ON 1.5 CUBIC YARDS OR GREATER SHALL NOT BE STORED OR PLACED WITHIN FIVE FEET OF COMBUSTIBLE WALLS, OPENINGS OR COMBUSTIBLE ROOF EAVE LINES UNLESS AREAS CONTAINING DUMPSTERS ARE PROTECTED BY AN APPROVED SPRINKLER SYSTEM. 13) THE MODIFICATION OF FIRE SPRINKLER SYSTEM (IF REQUIRE) WILL BE SEPARATELY SUBMITTED FOR PLAN CHECK AND PERMIT BY AN LICENSED FIRE PROTECTION CO. 14) EXTEND AND/OR MODIFY SPRINKLER AND LIFE SAFETY SYSTEM AS NEEDED AND APPROVES BY LOCAL AUTHORITY. HEALTH DEPT. REQUIREMENTS 3 1. All EQUIPMENT MUST BE LISTED BY NATIONAL SANITATION FOUNDATION (NSF) AND MEET APPLICABLE NSF INSTALLATION REQUIREMENT OR EQUIVALENT. ALL EQUIPMENT MUST BE ON SIX—INCH HIGH ROUND, WASHABLE, WATERPROOF LEGS, OR PLACED ON CASTERS AND BE EASILY MOVABLE OR SEALED TO THE FLOOR AND COVED WITH A 3/8—INCH RADIU`. FOUR —INCH HIGH COVE. 2. ANY EQUIPMENT DISCHARGING LIQUID WASTER SHALL DRAIN TO A FLOOR SINK VIA LEGAL GAP (I.E. THREE COMPARTMENT SINK, FOOD PREPARATION SINK, WALK—IN COOLER, STEAM TABLE, ICE MACHINE, SODA MACHINE, ETC.) 3. FLOOR SINKS SHALL BE INSTALLED FLUSH WITH THE FLOOR SURFACE AND BE LOCATION SO AS TO BE READILY ACCESSIBLE FOR CLEANING AND REPAIR. 4. WITHIN 60 DAYS FROM THE COMMENCEMENT OF OPERATION, THE OWNER OR EMPLOYEE MUST HAVE SUCCESSFULLY PASSED AN APPROVED AND ACCREDITED FOOD CERTIFICATION EXAMINATION. THE FOOD SAFETY CERTIFICATION SHALL BE RETAINED ON FILE AT THE FOOD FACILITY AT ALL TIMES, AND SHALL BE MADE AVAILABLE FOR INSPECTION . THE RESPONSIBILITY OF THE CERTIFIED OWNER OR EMPLOYEE SHALL INCLUDE THE SAFETY OF FOOD PREPARATION AND SERVICE 5. FINAL INSPECTION AND APPROVAL IS REQUIRED PRIOR TO BEGINNING OPERATION. THIS DEPARTMENT REQUIRES AT LEAST FIVE (5) WORKING DAYS NOTICE TO ARRANGE FOR FINIAL INSPECTION. CONSTRUCTION NOTE: 4 1) ALL CONSTRUCTION WORK SHALL CONFORM WITH THE REQUIRE MEETS OF THE LOCAL BUILDING CODE AND ALL OTHER CODES AND ORDINANCES HAVING JURISDICTION. 2) THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO STARTING WORK, INCLUDING EXACT LOCATION, SIZE, DEPTH AND AVAILABILITY OF ALL UTILITIES CONCERNED. AND ALL CONSTRUCTION WORK MUST BE FOLLOW THE CITY AND HEALTH DEPARTMENT'S APPROVED PLANS. 3) ANY DISCREPANCIES AND / OR OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER AND THE CONTRACTOR AT THAT TIME. ANY CHANGES TO THE APPROVED PLAN, MUST BE BROUGHT TO THE PLAN CHECKERS ATTENTION. 4) GENERAL CONTRACTOR SHALL PROVIDE PROPER BACKING FOR ALL WALL MOUNTED EQUIPMENT AND SHELVING, REGULATIONS. 5) CONTRACTOR ACTIVITY SHALL NOT BEGIN BEFORE 7 A.M. OR CONTINUE LATER THAN 7 P.M. AND 8 A.M. TO 5 P.M. ON SATURDAY. SITE PLAN SCALE: 1 /32" = 1'-0" CHEF TONY DIM SUM (TENANT IMPROVEMENT ONLY) 1108 S. BALDWIN AVE. B 4&5 ARCADIA, CA 91007 5 VICINITY MAP N.T.S • SITE SCOPE OF WORK PREVIOUS RESTAURANT CHANGE OWNER TO BE REMODEL. T.I. WORK CONSISTS OF THE FOLLOWING: CHANGE IN COOKING EQUIPMENT. DATA OWNER: YI DOING GROUP, INC. TEL: (626) 400-8086 ADDRESS: 1108 S. BALDWIN AVE. ARCADIA, CA 91007 DATA: 1) RESTAURANT AREA: 2,617 S.F. REMODEL AREA: 120 S.F. 2) CONSTRUCTION TYPE: V—B (EXISTING SPRINKLER SYSTEM) 3) OCCUPANCY GROUP: A-2 4) STORY: ONE 5) NO ALCOHOL SERVED. 6) EXTERIOR SIGN UNDER SEPARATE PERMIT BY SIGN CO. 7) EXISTING HVAC SYSTEM REMAIN NO CHANGE "ALL HVAC EQUIPMENT IS EXISTING" UI.I,Ur1-HINI., T LUHU W-\LI,ULN I IUIN CBC TABLE 1004.1.2 SECTION AREA OCCUPANCY LOAD KITCHEN AREA 838 S.F. 838 SF/200 = 4.19 SERVICE AREA CUSTOMER AREA 70 S.F. 70 SF/200 = 0.35 1028 SF/15 = 68.5 1028 S.F. HALLWAY & RESTROOM etc. 681 S.F. _ TOTAL 2,617 S.F. 73.04 OCCUPANT LOAD SHALL BE 74 PERSONS CODE OF DESIGN (iependable !yesign Inca, 615 LAS TUNAS DR. #205 ARCADIA, CA 91007 6 Tel: (626) 388-4919 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Dependable Design Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Dependable Design Inc. \I r N 0 0 0) J U Z O � Q F- a Z W U < W _ C) Ln Ln � Z m a' � O > � Q �— Z LL_ z o Z W = Q U m v; 00 0 z 0 Q U 0 J U w 0 o_ 2019 CALIFORNIA BUILDING CODE (CBC) OJASS4oc`��� 2019 CALIFORNIA ELECTRICAL CODE (CEC) Iwo 2019 CALIFORNIA MECHANICAL CODE (CMC) 2019 CALIFORNIA PLUMBING CODE (CPC) 0 No. C 40169 * Exp.9-30-22 m 2019 CALIFORNIA FIRE CODE (CFC) aTF c,a-Go`��\P 2019 CALIFORNIA ENERGY CODE (CEES) 2019 CAL. GREEN BUILDING CODE(CGBSC) AND LOCAL GOVERNMENT CODE I nnrc. Ioc nc�i. INDEX COVER SHEET & SITE PLAN M- I. 1 CnIJ IiIVU FLUUF\ OC I,CILIINU r-LMIN A-2 H.C. DETAILS M-1 I MECHANICAL GENERAL NOTES AND DETAILS M-2 ROOF PLAN P-1 PLUMBING GENERAL NOTES AND DETAILS P-2 PLUMBING PLAN Date: 1212912020 Job No: C20 1 1 3G Design By: Drawn By: J.A. Scale: I A5 SHOW ON Sheet title: Sheet COVER SHEET A=O J'N ENVIRONMENTAL HEALTH l SPECIALIZED SURVEILLANCE AND ENFORCEMENT BRANCH PLAN CHECK PROGRAM - BALDWIN PARK COUNTY oFLoSaNCEEs cAxIFOR� 5050 COMMERCE DR, BALDWIN PARK, CA 91706 Public Health PHONE: (626) 430-5560 VVM.PUBLICHEALTH.LACOUNTY.GOV/EH OFFICIAL PLAN REVIEW REPORT DATE 01/21/2021 1 EH,' VERNY GRAJEDA PLAN CHECK NUMBER SR0240986 PROGRAM ELEMENT 1703 - RESTAURANT (2,000-3,999 SF) OWNER / REQUESTER JAMES AN, ASSISTANT DBA CHEF TONY DIM SUM ADDRESS 1108 S BALDWIN AVE, ARCADIA, CA 91007 CORRECTIONS COMPLETED CORRECTION CATEGORY DATE IDENTIFIED DATE CORRECTED FOOD PREPARATION SINKS 12/17/2020 01/21/2021 HANDWASHING FACILITIES 12/17/2020 01/21/2021 TOILET FACILITIES 12/17/2020 01/21/2021 WATER SUPPLY 12/17/2020 01/21/2021 WASTE WATER/PLUMBING 12/17/2020 01/21/2021 EQUIPMENT/STORAGE 12/17/2020 01/21/2021 FOOD PROTECTION/FOOD STORAGE 12/17/2020 01/21/2021 VENTILATION 12/17/2020 01/21/2021 PLAN SUBMITTAL/REMODEL 12/17/2020 01/21/2021 ADDITIONAL REQUIREMENTS PLAN APPROVED. EXISTING FACILITY, NEW OWNER. Help us serve you better by completing a short survey. Visit our website at www.oublichealth.lacounty oov/eh. EHS Signature Page 1 ot3 DATE 01/21/2021 EHS I VERNY GRAJEDA PLAN CHECK DUMBER SR0240986 PROGRAM ELEMENT 1703 - RESTAURANT (2,000-3,999 SF) OWNER / REQUESTER JAMES AN, ASSISTANT DBA CHEF TONY DIM SUM ADDRESS 1108 S BALDWIN AVE, ARCADIA, CA 91007 COMMENTS FINAL APPROVAL STATEMENTS PLAN IS APPROVED. ALLOW AT LEAST THREE (3) TO FIVE (5) WORKING PRIOR TO ARRANGE FORA FINAL INSPECTION. NOTE: THE FOLLOWING MUST BE COMPLIED WITH PRIOR TO CALLING FOR A FINAL INSPECTION. 1. ANY MODIFICATION AT THE APPROVED PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE PLAN REVIEWER PRIOR TO CALL FOR FINAL INSPECTION 2. A COMPLETE PUBLIC HEALTH APPLICATION ATTACHED) MUST BE PROVIDED WITH THE COPIES OF THE REQUIRE OWNER'S DOCUMENTS. 3. PROVIDE A COPY OF FRONT AND BACK OF BUILDING & SAFETY JOB CARD WITH FINAL SIGNATURES OF MECHANICAL, FIRE, PLUMBING, ELECTRICAL. 4. THE HEALTH DEPARTMENT APPROVED PLAN AND ANY APPROVED PLAN MODIFICATION MUST BE AVAILABLE AT THE JOB SITE AT THE TIME OF INSPECTION. 5. ALL UTILITIES MUST BEAT 120' F. AND ABOVE. HAND WASHINGN AT 100 ° F. BUT NOT OVER 109°. 6. ALL EQUIPMENT MUST BE ANSI CERTIFIED, ALL EQUIPMENT ON THE PLAN MUST BEAT THE SITE, INCLUDING SODA DISPENSER. IF EQUIPMENT IS MISSING OR ADDED, PLANS MUST BE MODIFIED ($167.00 EXTRA FEE). 7. FACILITY MUST BE CLEAN AND IN GOOD SANITARY CONDITION (EITHER IF IS AN EXISTING FACILITY (SITE EVALUATION). 8. HAND WASHING CLEANSER AND SINGLE -USE TOWELS SHALL BE PROVIDED AT EACH HAND WASHING SINK / LAVATORY. • IF CONSTRUCTION IS NOT COMPLETED WITHIN TWELVE (12) MONTHS FROM THE DATE OF APPROVAL NEW PLAN SUBMISSION AND APPROVAL MAY BE REQUIRED. • ESTABLISHMENT NOT IN COMPLIANCE MAY REQUIRE AN ADDITIONAL THREE (3) TO FIVE (5) DAYS FOR RESCHEDULING. • CALL (626) 430-5560 TO SCHEDULE A FINAL INSPECTION. Help us serve you better by completing a short survey. Visit our website at www.publichealth.lacoun y. oq v/eh. EHS Signature Page 2 of 3 DATE 01/21/2021 EHS VERNY GRAJEDA PLAN CHECK NUMBER SR0240986 PROGRAM ELEMENT 1703 ' RESTAURANT (2,000-3,999 SF) OWNER /REQUESTER JAMES�AN,SISTANTDBA CHEF TIM SUM ADDRESS 1108 S BALDWIN AVE, ARCADIA, CA 91007 DISCLOSURES Prior to construction and approval from the Los Angeles County Department of Public Health Environmental Health Division (DPH-EH) Plan Check Program, final inspections must be obtained from Building and Safety (mechanical, plumbing, electrical) and all other enforcement agencies. Failure to obtain a Public Health Permit/ License prior to operation of the facility/establishment is a misdemeanor violation. Construction of the food facility/ establishment must be completed and approved within twelve (12) months from the date of approval to avoid submitting new plans. A copy of the approved plans must be available at the time of the field construction review. All utilities must be on and operational at the time of the field construction review. Please contact your plan check inspector at least 3 days prior to the field construction review. Two field inspections will be covered under the Plan Check fees assessed upon plan submission. A charge will be assessed for each subsequent field construction review. Help us serve you better by completing a short survey. Visit our website at www.publichealth.lacounty oov/eh. EHS Signature Page 3 of 3 0 mC EQUIPMENT FIXTURE SCHEDULE NO QUA DESCRIPTION MARK AND MODEL ELECTRICAL PLUMBING VOLT RATING LOCATION DESCRIPTION WATER WASTE A.F.F GAS (BTU) E 1 3 BOOTH & TABLE CUSTOM-MADE E 2 1lot TABLES & CHAIRS CUSTOM-MADE El 3 2 DISPLAY REFREGERATER "LEADER" 115 5 AMPS WALL PLUG-IN E 4 1 CASH REGISTER BY OWNER 115 40 W WALL PLUG-IN E 5 1 34' H. FRONT COUNTER S.S. CUSTOM-MADE E 6 1 BACK COUNTER CUSTOM-MADE E 7 2 SERVICE TABLE CUSTOM-MADE E 8 1 ICE MAKER WASTE TO F S) 115 13 AMPS WALL PLUG-IN E 9 1 PREP. SINK (WASTE TO F/S) W S.S. SPLASHING GUARD 6"H.FROM SIN) EAGLE 1 2 C.H. F S E 10 1 S.S. WORK TABLE "GWS" N 11 1 DISPLAY CASE "STAR" 115 10 AMPS WALL PLUG-IN E 12 1lot DRY STORAGE WIRE SHELVING 4 TIERS) 24'x4=96' LINEAR FEET "GSW" E 13 1 EXH. HOOD 1 TYPE "I" 6'-0"X4'-0"w/AUTO FIRE PROTECTION SYSTEM ACCUREX 208 1 HP ROOF "J" BOX E 14 1 MAKE-UP AIR ACCUREX 115 3 4 HP ROOF toJ' BOX 1 2 C.W. E 15 1 CHINESE WOK RANGE WASTE TO F/S) ABC 1 2 C.W. F/S 220,000 TRUE TWT-48 115 5 AMPS WALL PLUG-IN E 17 1 SER HAND SINK WITH SOAP & TOWELS DISPENS "EAGLE" 1 2 C.H. "EAGLE" 19 1 DISH WASH MACHINE WASTE TO F/S CHEMICAL SANITATION 120 3 4 HP WALL PLUG-IN 1 2 C.H. F/S 20 1 3-COMP SINK W/2-18' DR. BD. WASTE TO F/S "EAGLE" 3 4 C.H. F/S 21 1 S.S. WALL SHELF "EAGLE" JE 22 1 S.S. WORK TABLE "GWS" WARMER WASTE TO F/S) "EAGLE GROUP" HT6CB-240 208 10 AMPS ROOF PLUG-IN 24 2 S.S. WORK TABLE "GWS" STOVE "IMPERIAL" ISPA-18-2 180,000 26 3 DEEP FRYER W 12 H. S.S. SPLASHING GUARD "FEY MASTER" 110,000 E 27 1 EXH. HOOD #2 TYPE "I" 24'-0"X4'-0"w AUTO FIRE PROTECTION SYSTEM ACCUREX 208 1 HP ROOF "J" BOX E 28 2 MAKE-UP AIR ACCUREX' 115 3 4 HP ROOF "J" BOX 1 2 C.W. E 29 1 CHINESE WOK RANGE WASTE TO F/S) "ABC" 1 2 C.W. F/S 440,000 E 30 1 STEAMER "CLEVELAND" PGM-200-3 1 2 C.H. F/S 220,000 "GSW" E 32 1 HAND SINK WITH SOAP & TOWELS DISPENSERS EAGLE 1 2 C.H. TURBO AIR MST-48-N 115 4AAMPS ROOF PLUG-IN E 34 1 WALK-IN FREEZER WASTE TO F/S GENERAL #25219 208 1 2 HP WALL PLUG-IN F S E 35 1 WALK-IN COOLER WASTE TO F/S GENERAL #25219 208 774 -HP WALL PLUG-IN F S E 36 1lot WIRE SHELVING FOR WALK-INS "GWS" -M 37 1 AIR CURTAIN "MARS"MARS-36N 208 2.5 AMP WALL PLUG-IN 38 1 STEAMER WASTE TO F/S "SINO' WOK1 1 /2 C.W. 100,000 E 39 1 EXH. HOOD #3 TYPE "I" 8'-0"X4'-0"w/AUTO FIRE PROTECTION SYSTEM ACCUREX 208 1 HP ROOF Hill BOX (-E7 40 1 MAKE-UP AIR ACCUREX 115 3 4 HP ROOF "J" BOX 1 2 C.W. E 41 1 CHINESE B.B.Q. OVEN "GSW" 58,000 E 42 1 CONVECTION OVEN "HOBART" HOBA-HGC-501 44,000 77 43 1 EXH. HOOD #4 TYPE "I" 4'-O"X4'-0"w/AUTO FIRE PROTECTION SYSTEM BY CONTRACTOR 208 1 HP ROOF "J" BOX FRO SIN "ACCURE" 115 3/4 HP ROOF Hill BOX 1 2 C.W. 45 1 2-COMP SINK W/6"H. FROM SINK S.S. SPL. GUAR ( WASTE TO F/S) "GWS" 1 2 C.H. F/S PE ANING EQ. W BACKFLO� PREVENTION DEVICE 1 2 C.H. 47 1 100 GAL. GAS WATER HEATER 'BRADFORD WHITE' UCGlOOH2703N 3 4 C.W. 270,000 E 48 1 1 S.S. WORK TABLE ALL EQUIPMENT AND FOOD STORAGE SHELVING MUST MEET "NSF" OR "ANSI" CERTIFICATION. (E): EXISTING (N): NEW DRY FOOD STORAGE WIRE SHELVES CALCULATION QUA WIRE SHELVES 1 TIERS LINEAR FEET 2 2 FT. 4 f 2X2X4 = 16 FT. 2 3 FT. -- 4 _ _2X3X4 = 24 FT. 5 4 FT. - 4 5X4X4 = 80 FT. TOTAL PROVIDE LINEAR FEET 120 LINEAR FEET REQUIRED LINEAR FEET 96 LINEAR FEET i (KITCHEN AND FOOD PREP WORK AREA 124 S.T. REQUIRED DRY STORAGE SHELVES) FINISH SCHEDULE ROOM FLOOR BASE REMARKS WALL CEILING FINISH SCHEDULE NOTE: I 1) Wall and ceilings in all areas except dining areas all be durable, Q w cn ? ,-, _ F- 0- = m m it F- = m o smooth, and nonabsorbent, with a light colored light colored is defined as having a light reflectance value of 707. or greater.), easily cleanable, washable finish. z '- w Q ^ s ~ z o ~ U=� w it ~ z m ¢ w .. w 2) All counter surface including underside to be durable smooth, nonabsorbent, easily cleanable and washable finish �m y require - z w rn o O O � _ �' o ¢ z ¢ _ _ ¢ z >- z z ¢ z z ¢ stainless steel or NSF approval higgh pressure laminate. 3) Flooring the base be ^ s o O 3 w V) U; - C° Q m w m ° ►- r- -� u L' -' ° v > -� z w m n rr a under equipment and at coves shall comp- letely smooth. floor surfaces which contain slip resistant agents be to traffic NAME O N o J z = = Ur J oo \ z E a d eo z I U a ¢ n z¢ C U o) U U shalt restricted areas only. 4) All equipment shall be either easily movable (i.e., on casters), .. x _ o J w ¢ - cp O - ¢ t- w = m _ ¢ �, ¢ J ¢ O z � -� -i z =, ¢ z O � = U z d c� m ¢ c� min. 6 inch rounded metal legs, or sealed to min. 2 inch solid masonry island with min. three -eighths inch coved radius. w iv z > w L `I- r- > U '' Un ¢ ¢ > w w �' Un > �_ z �= 5 Floor Smooth Conc. must be To sett e ceramic coved base. ) P- YP w r ►- w _J z -� ¢ J -� �- Ld Un �- `� J ¢ (n _J V) w W-- �- ¢ — I I- U (n w D 0 W U J ¢ in o O v (n o MATERIALS NOTE: -J >- v > z co >- U ¢ m w w Ur w � c� J � ¢ O z z U -� co ¢ ¢ U ¢ O w -+ m ° > U U = c� CEILING PANELS the following ceiling panels area roved --- 9 9 P PP of g Ur ¢ w �- O ¢ o' � � ¢ (n w m z P:: __ ¢ co ¢ W- i J = z (n Un W - ¢ U = ¢ _ U - (n ¢ m -- ¢ ¢ �t W- O ¢ N , Armstrong#870 Mina board ML (Mtl laminate; nonperforated) Domtar Gypsum 3270 White vine facing pane ¢ z w O --- w ¢ >- z to F- w U) ¢ I W ¢ w x O x U.S.Gypsum 32 Vinci rock w CY U > — -- -- Q = Un - g Un -- -- Cy w U . - > -- cfi � - - O U - -- o --- w w w = - --- - -- - — — w U I _ o = - - - - ----._— cv _ cn - - cv --- U.S.Gypsum 515 Enwrogard with clean room facing FLOOR COVE ING Tiles --- American Olean, Del Tile, Approved Topset Ceramic coved base --- B & W the Co. #S-3619T Huntington Pacific (OTW, Inc.) #S-3619T Approvaed Sheet vinyl --- Arrstrong "Classic Corlon"(86000 Series) Armstrong Custom Corlon, (86000 Series) Torket 'Expression Optima (05800 Series) --- — -- — -- - --- CUSTOMER AREA - --._ 0 0 0 SERVICE AREA 0 0 0 010 10 0 0 0 0 0 KITCHEN/PREP.& LOCK 0 0 0 0 00 0 0 0 0 0 0 0 Approvaed Conc. Sealers --- Ameritone 7101, Aque Mix Chioice15 O O 0 O 0 O 0 O O O O O MOP SINK AREA ALL INTERIOR FINSHES SHALL BE IN COMPLIANCE WITH CH.8 OF 2019 CBC FOR FLAME AND SMOKE INDEX REQUIREMENTS. RESTROOMS �� Q 0 0 0 0 0 0 0 0 010 0 0 A GYP. BOARD QUARRY TILE OR CERAMIC TILE COVED INTO FLOOR QUARRY TILE OR CERAMIC TILE WOOD SUPPORT TYP. CERAMIC OR QUARRY FLOOR AND COVE BASE TILE DETAIL WOMEN SIGN DETAIL SEE A-2 DOOR NOTES: EXISTING FRONT ENTRY DOOR 3'X6'-8" GLASS DOOR SELF -CLOSING. 32" CLR. EXISTING REAR EXIT DOOR 3'-0"X6'-8" DOOR SELF -CLOSING. 32" CLR. PROVIDE ILLUMINATED UPPER/LOWER "EXIT" SIGN PER CBC 1011. LIMIT THRESHOLD = 1 2" MAX. LOWER 10" OF THE DOOR SALL BE SMOOTH PLANE SURFACE THE MAIN EXIT SHALL COMPLY WITH TITLE-24 SIGN 1" HIGH LETTERING ON THE ABOVE MAIN EXIT DOOR: "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED." (CBC 1008.1.9.3) DOOR PANIC HARDWARE 5LB. MAX. OPENING FORCE (CBC 1008.1.10.) NEW DOOR SHALL BE OPENABLE FROM INSIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 7'-6ff PAN DET 4'-7" A 6'-5" <�S 9f-1ff 50'-10" ---- I ­­ - - ---- 100% MECHANICAL MAKE-UP AIR WITH AN * AIR CURTAIN MICRO - SWITCH -DOOR- ACTIVATED. ji-- CLR. 10, --0-". f spendable esign Ins. 615 LAS TUNAS DR. #205 ARCADIA, CA 91007 Tel: (626) 388-4919 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Dependable Design Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may b r i e used b o disclosed to an Y Y Y person, firm, or corporation without the written permission of Dependable Design Inc. }77 r k 36 x18 ,60 x1: , — F 2 0 Ln ca STAF 48 I 42 O �.__ 37 35 WALK-IN REST OM 36" DOOR 47 - - _ _ Ai - -_ _ _ _ _ O O COOLER o k 32" CLR.OSE 46 _ 41 26 �, 39 3 8 0 „ f f, s oo y O { 36 x18 60 x18 + :::: � J GD � 00 k , r� - + ` WALK-IN o0 LOCK ROOM ? TCHEN REMAIN HANGS Co Co 34 FREEZE o (EXISTING) 36to 31 ` QD33 3'-0"36%18" 60%18PREP�. AREA O WZL ff p 36 x18 3� ENS ` o - o! 0 COOKING 23 STR00 �- 25 30 28 29 6 AREA 25 24 3 21 20 F/S 27 2 - 1 - i _ - - F' _S 0 4- + 28 j FAN -- EJ O 0Rb-XX P.IR N�— YXX qK 18 uxtidlft 9triF __ -Do, 3, 0,f 3f - - _ - _ _ m "x18" o 48 _ O ;00 z v — - - x V o 0 J -- -- - Ca o �' Q DINING AREA �'0 f 3'U6-,: tx (EXISTING) 5 - Q LU O o / 30"X4$$" CLR. FR NT COUNTE i o - 'N ElTOE 36' CLR. SPACE O RR CLEA SPACE MAX.MA 34" HIGH il 15 DETAIL SEE A-2 70& 9Q ¢ 13 m w;ono w Cl I D LUCnIJ cct TWD - + 16 Z LL z O OOKIN QAREA U o w O j 1 24"x18" J --- LU Q m j 14 .-- Cl 3'-7CD" 10 vi - --- — + 00 Cl LL- CUSTOMER AREA O O CD001 Q O O O J r � CD 00 7) U EXIT 51G d 3EE A-2 13 TACTILE EXIT SIG DETAIL SEE A-2 13 PROPOSED FLOOR PLAN_ t COUNTY OF LOS ANGELES * Dr, PARTIVrENT Or PUDLIC IMeALL ENVIRONMENTAL 141RAIM11 PLAN CIIECK PROCRANI THE PROPOSED CONSTRUCT ION/EQUIPrtiA-�z 3 ! I s'I'ALLA'f!ON T' APPROVED. EXC''P'I'AS NOTED 1'YPL c FFOOD : HE APPROVAL s ION OFAN' LAV , 01? TANCE OR I S J ON. 1,PPROVED: / P2y r DATE L.A. COUNTY 116MI OFFICER SEE PLAN CORRECnON SHEET (ATIACHED)-- (DAM q 1S A V4IS DE VIEANOR VIOLATION TO BECWtt ;PERATION i7JI"11­IOUT A DIAL INSPECrT10IN AND VALID IHEAffH PERMIT. YOUR HEAL U H P;7R�4IT NUILL BE ISSU-FD BY THE CHECKER L11-- AREAS O1 1,alil 9 LLTG FOOD=,STt3ti1✓1S(iila N41 iS'r ALSO HAVE AVE A FE'll` . ON5T JJ1 ;At; itJST II:. WARD ACCESSIBLE ENTRANCE SIGN A-2 30 DETAIL SEE A-2 3a LOS A rGEELES COUNTY' x DEPwrMENT OF PUBL}C HEALTH v R, PLAN CHECK PROGRAM H 505,3 CO�AMERCE DRIVE' ' PALDIVIIN PARK, CA 917t?'d 11141 (6) 450-5560 w $}y^ _},..i.:N�. .,..ai.'1......+s,:o'....<.. F.x='.:r ..;;.i.:., .rr+=t, s'f F.•r5t.'.., WARN THEAI33E t OF .STOMEA THIS FAir4UN I5 Nt- _ D FOR THE .-ONSUAW11ION OF ALL. ,H; -IC, BEVERAGES . 8r1NAL INi' TIO,IV 3� ARE Alt�itdlllsi19 �A 7� i3tA k OPER>Iilfyyr . TI�I: iiiEP,IrgY�i1#EI�� I'IEu '. _5 �r-- L��..�:1'.T��>E1< 4Pl#R�IfJ�i �� ►� PR'" TO THE OA E OF INI FINAL, i { � I f C 40169 9-30-22 ,' f DATE: REV1510N: / I \112117/201 Health Corrections Date: 1 2/29/2020 Job No: C201 13G Drawn Dy: JENNY Scale: 1 /4"= 1 '-0" PROPOSED FLOOR PLAN spendable esign Inc. .,,,....,,,„,......„4„,.,,__,,, 615 LAS TUNAS DR. #205 ARCADIA, CA 91007 Tel: (626)388-4919 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Dependable Design Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Dependable Design Inc. 50'-10" - 50 8'-0" HOOD ACCESSIBLE ENTRANCE SIGN -1 DETAIL SEE I I I I SELF-CLOSE I I I , ( 32" CLR. -L I / , 0 W/H X — - EXIT )6"X1C6O"x18 11X3 /(a.WOMEN - .- X. 1 .B.Q. OVEN \, C, ('", REST QGJM \I REST { I l 7< t \X \ 1 . 30"X48>CLR. I / '� o \N 00X $ 1 - -- \- - 36"x18" 60"x18„ r ,..7( i \ 3j1 / i /co 1 li\j. X b a I. 11. KITCHEN REMAIN NO CHAN :x l PREP. AREA / �V 36"x18" 60"x18" �� 3' 2" �6x1\ \ i . Iv6S - COOKING 6 \ \ 0 ST ROON� AREA / \ \ \ O i j.h � i �� —_'Q I i = ii, I tiD #ii 0 ll 4 110 Y I Or) ;,al: ( ) ( ) , ) , el QCD - a I _____-) C_Ifj C (----- 48 x18 ) (----- II I .ter. .._ a. /�,� �I 0---) ( ) :7` co 0 01 m �� of O LLi DINING AREA [S1 3' 6" 1 X - Ail. _ < LL,1 , - t- i 0 '4,61' ,/ w Q IMAI < \ g M( 1> - 0 'S w - I i Li il, 1 CO x . _ ___ Cirri 1 )(11 n _ , ,i____ ____L_ , - OW I '''.: 1 .. 16.4it CI \ I= ..�We) k 0 0, I W s 1 I , -- — l CUSTOMER AREA 0 0 �.� �.� 0 CL Aft. , /Ahlk 0 O C 40169 I EXIT EXIT 0 0 0 0 9-3o-2z s" DOOR EXITF �` 36" DOOR „ , , t EXI T I l- SELF CLOSE I I r- r— -I —I I �� I II II 1 i G SELF-CLOSE I ILi fl 32" CLR. L-, ri L J 32" CLR. I DATE: REVISION: EXI TIN L CEILING LEGEND R PLAN /.��► XI T I N I L I N LAN ak SCALE: 1/4"-1 '-0" q11, 2X4 FLUORESCENT LIGHT Date: I I/24/2020 SCALE: 1/4"=1 '-0" qr Job No: C201 13G 0 RECESSED LIGHT Drawn By: JENNY FAN Scale: I/4"= I '-0" SURFACE LIGHT Sheet title: EXISTING FLOOR * CEILING PLAN 1 1EXITr EXIT SIGN & LIGHT A si 0 GENERAL NOTES 1. ALL MECHANICAL WORK SHALL COMPLY WITH LOCAL APPLICABLE CODE AND CALIFORNA MECHANICAL CODE. 2. ROOF OPENINGS & PLATFORMS TO BE CURBED AND LEVEL, 6" MINIMUM HEIGHT, FLASHED AND CAPPED WITH SHEET METAL. A/C CONTRACTOR TO COORDINATE REQUIRED SIZES AND LOCATIONS WITH GENERAL CONTRACTOR. 3. A/C UNIT ON GROUND OR ROOF TO BE CURBED AND LEVELLED. 4. CONTRACTOR SHALL INSTALL ALL DUCTWORKS TO SUIT THE STRUCTURAL CONDITION. PROVIDE ALL NECESSARY OFFSETS AS REQUIRED. VERIFY WITH ARCHITECTRUAL, STRUCTURAL, ELECTRICAL AND PLUMBING DRAWINGS. 5. EXPOSED DUCTWORK AND PLENUMS TO BE KEPT TO A MINIMUM AND WATERPROOFED. SEAMS TO BE CAULKED WITH SEALING MASTIC BEFORE CLOSING, AND THEN COVERED WITH SECO ALUMINUM PLAS-T-COTE ROOF COATING OR EQUAL SEALING COMPOUND. EXPOSED DUCTWORK AND PLENUMS TO BE LINED INTERNALLY WITH 1" THICK 3-LB DENSITY DUCTLINER. 6. DUCT INSULATION SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF UNIFORM MECHANICAL CODE. INSULATE ALL SUPPLY AND RETURN AIR DUCTS WITH 2" THICK FIBERGLASS BATT INSULATION WITH VAPOR BARRIER FOR DUCT IN ATTIC AND 1" THICK FOR DUCT IN CEILING SPACE. 7. DUCT CONSTRUCTION SEALANT: PROVIDE MASTIC OR TAPE DUCT JOINT SEALANT. 8. DUCTWORK SHALL BE CONSTRUCTED, ERECTED AND TESTED IN ACCORDANCE WITH THE LATEST EDITION OF UNIFORM MECHANICAL CODE CHAPTER 6. 9. ALL DUCTWORK IN STUDWALLS TO BE ISOLATED WITH 1/4" FELT IN THE DUCT SUPPORTS AND WHERE IT MAKES CONTACT WITH THE BUILDING CONSTRUCTION. INSTALL ONE DUCT ONLY IN EACH STUD SPACE. 10. ALL DUCT DIMENSIONS ARE CLEAR INSIDE. ALL DUCTS SHALL BE FIRMLY SUPPORTED OR HUNG AND NEATLY ALIGNED AND INSTALLED. SPACE HANGERS AS REQUIRED TO SUPPORT THE DUCTS WITHOUT SAGGING AS REQUIRED BY THE BUILDING FRAMEWORK, AND AS REQUIRED BY OTHER INTERFERENCE. LOCATION AND SPACING OF HANGERS AND SUPPORTS SHALL BE COORDINATED BY THE CONTRACTOR. FURNISH AND INSTALL NECESSARY SUPPORTING MATERIAL AND ADDITIONAL STRUCTURAL MEMBERS. SEAL OPEN SPACE BETWEEN DUCTS & WALL COORDINATE DUCTWORK WITH THE LIGHTING FIXTURES, CEILING SUPPORT SYSTEM, AND ACCESS DOORS ETC. 11. CONTRACTOR TO CHECK ARCHITECTURAL REFLECTED CEILING PLAN FOR CEILING DIFFUSER, RETURN AIR REGISTER & CEILING EQUIPMENT ETC. 12. ALL EXTERIOR LOUVERS AND DOOR LOUVERS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR. TIMER, TIME CLOCK & CONDUIT BY ELECTRICAL CONTRACTOR. 13. A/C CONTRACTOR SHALL INSTALL NEW CEILING DIFFUSERS & GRILLES AS NOTED ON PLANS. ALL CEILING DIFFUSERS SHALL BE METAL-AIRE 7000 SERIES PERFORATED OR APPROVED EQUAL. 14. INSTALL MANUAL BALANCING DAMPERS IN ALL BRANCH DUCE RUNS TO INDIVIDUAL DIFFUSERS AND AS REQUIRED TO CONTROL AIRFLOW FOR SYSTEM BALANCING. 15. INSTALL ACOUSTIC LINING IN DUCTWORK FOR 10 FEET ON EACH SIDE OF FAN (SUPPLY AND RETURN). 16. PROVIDE BACKDRAFT DAMPERS AND BIRDSCREENS ON EACH DUCT FROM INTERIOR SPACES TO THE OUTSIDE UNLESS PROHIBITED BY CODE. 17. PROVIDE ACESS PANELS FOR ALL EQUIPMENT CONCEALLED IN ACCESSIBLE SPACES. COORDINATE SIZE AND LOCATION WITH ARCHITECT. 18. CONTRACTOR TO INSTALL APPROVED AUTOMATIC FIRE DAMPERS IN ALL DUCT, DIFFUSERS, GRILLS, ETC. WHERE PENETRATING RATED WALLS, FLOORS, AND CEILING ASSEMBLIES. IN FIRE RATED CORRIDOR SHALL INSTALL COMBINATION FIRE AND SMOKE DAMPER AS REQUIRED BY CALIFONIA BUILDING CODE. 19. ALL CONDENSATE DRAINS SHALL BE TRAPPED AND PIPED TO THE APPROVED RECEPTOR. DRAIN SHALL SLOPE AT NOT LESS THAN 1/8" PER FOOT (1%). 20. ALL A/C CONDENSATE LINES TO BE INSTALLED BY PLUMBING CONTRACTOR. REFER TO MECHANICAL DRAWINGS FOR LOCATION OF CONDENSATE LINES. 21. ALL MECHANICAL EQUIPMENT SHALL BE LABELED TO THE SPACE SERVED. 22. A 120-VOLT RECEPTACLE SHALL BE LOCATED WITHIN 25 FEET OF THE EQUIPMENT FOR SERVICE AND MAINTENANCE PURPOSES. 23. EXHAUST OUTLETS SHALL TERMINATE IN ACCORDANCE WITH THE REQUIREMENTS OF UMC CHAPTER 6. AND 10'-0" ABOVE GRADE. 24. OUTSIDE AIR INTAKE SHALL BE 10'-0" AWAY OR 3'-0" BELOW ANY APPLIANCE VENT OUTLET OR EXHAUST FAN DISCHARGE OR PLUMBING. 25. FILTERS ON RETURN AIR PLENUM SHALL BE FARR 30/30 OR EQUAL 26. CONTRACTOR SHALL PROVIDE VIBRATION ISOLATION DEVICE FOR ALL MECHANICAL EQUIPMENTS AS ACOUSTIC CONTROL. 27. CONTRACTOR SHALL INSTALL THE EQUIPMENT OR SYSTEM PER MANUFACTURER'S INSTALLATION RECOMMENDATION. CONSULT WITH MANUFACTURING COMPANY IF NECESSARY. 28. ALL THERMOSTATS SHALL BE INSTALLED APPROXIMATELY 4 FT ABOVE FINISHED FLOOR. VERIFY LOCATION WITH ARCHITECT. 29, TEST & BALANCE ALL SYSTEMS ACCORDING TO CFM INDICATED ON PLANS. 30. ALL MECHANICAL EQUIPMENT SHALL BE BRACED OR ANCHORED TO RESIST A HORIZONTAL FORCE IN ANY DIRECTION AS FOLLOWS : * FIXED EQUIPMENT ON GRADE 22% OF OPERATING WEIGHT * FIXED EQUIPMENT ON STRUCTURE 33% OF OPERATING WEIGHT * FOR FLEXIBILITY MOUNTED EQUIPMENT USE 2 TIMES THE ABOVE VALUES, FOR * SIMULTANEOUS VERTICAL FORCES - USE 1 /3 TIMES THE HORIZONTAL FORCE. 31. MATERIALS EXPOSED WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME -SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED RATING OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH CBC STANDARD. 32. FLEXIBLE DUCT SHALL BE USED FOR TAKE -OFF AND LIMITED TO 6'-0". LEGEND SYMBOL - DESCRIPTION (L) - LINED DUCT - SIZE INDICATED IS SHEET METAL DIMENSION UTR - UP THRU ROOF DTR - DOWN THRU ROOF NIC - NOT IN THIS CONTRACT P.O.C. - POINT OF CONNECTION W/ - WITH W/O - WITH OUT G.C. - GENERAL CONTRACTOR P.C. - PLUMBING CONTRACTOR E.C. - ELECTRICAL CONTRACTOR M.C. - MECHANICAL CONTRACTOR CFM - CUBIC FEET PER MINUTE S.A. - SUPPLY AIR R.A. - RETURN AIR E.A. - EXHAUST AIR T.X. - TOILET EXHAUST KRHX - KITCHEN RANGE HOOD EXHAUST OSA - OUTSIDE AIR 0 - DIAMETER ROUND DUCT OT - THERMOSTAT F.D. - FIRE DAMPER Q.B.D. - QUADRANT BALANCING DAMPER B.D.D. - BACKDRAFT DAMPER M.V.D. - MANUAL VOLUME DAMPER C.D. - CEILING DIFFUSER C.R. - CEILING REGISTER E.P. - EXTENDED PANEL R.A.G. - RETURN AIR GRILLE E.G. - EXHAUST GRILLE T.T.B. - TRIM FLANGE TO FIT T-BAR GRID D/L - DOOR LOUVER U/C - UNDERCUT DOOR W.M.S. - WIRE MESH SCREEN CFM CUBIC FEET PER MINUTE OSA OUTSIDE (STANDARD) AIR M.V.D. MANUAL VOLUME DAMPER WMNMM FLEX DUCT ® CEILING DIFFUSER CEILING REGISTER --AT-•--ISWG SIDEWALL GRILLE OT THERMOSTAT N.I.C. NOT IN THIS CONTRACT SD DUCT MOUNTED SMOKE DETECTOR ROOF EQUIPMENT ROOF PARAPET , , PARKING LOT CEILING HOOD ENTRANCE BUILDING SECTION N.T.S. NOTE: ALL ROOFTOP MECHANICAL EQUIPMENT SHALL BE PLACED BEHIND A PERMANENT PARAPET WALL AND BE COMPLETELLY RESTRICTED FROM ALL GROUND LEVEL VIEWS. IF, AT THE GROUND LEVEL CAN SEE THE ROOF MECH. EQUIPMENT, PROVIDE SCREEN, AND THE COLOR PAINT SHALL BE MATCH TO THE EXISTING BUILDING. MAX. SCOOP LONGTH=3H POINT OF EXH. DISCHARGE 40" HIGH ABOVE THE ROOF BOTTOM HORIZONTAL DISCHARGE IN DIRECTKION OF PREVAILING WIND. OUTLET: 10'-0" FROM ADJACENT PROPERTY LINE OR AIR INTAKE OPENING AND 10'-0" ABOVE THE ADJOINING GRACE LEVEL. ADJACENT BLDGS ]� OR PARTS BLDGS l It REMOVABLE GREASE CONTAINER O 3M FIRE RATED (FIRE RATED TO COMPLY WITH - BUILDING CODE REQUIREMENT) 1 HR. FIRE CONSTRUCTION EXISTING ROOF JOIST JOIST 1$'_i CEILING LINE (2) LAYERS OF 5/8" TYPE "X" GYP. BOARD REMOVABLE COVER WITHOUT USE OF TOOLS AND THE DOOR SHALL HAVE APPROVED NONCOMBUSTIBLE GASKET MATERIAL UP WARD DISCHARGE 16 GAGE GALV. WELDED ANGLE IRON SUPPORT ALL WELDED EX�I�STING ROOF JOI,WIST _IXh'_-�__-___-- 14"x10" DUCT CLEM UT WITH 1 FITTING HINGED DOO5 OF STEEL CONSTRUCTION TO M TCH DUCT CEILING LI0 E 6"MIN. E- S.S. WALL COVERINGS MIN. ALL OPEN SIDE (BACK AND BOTH SIDES) 0 COOKING EQUIPMENT � I I 300_ FT. __ , - HOOD HANGER SUPPORT TO WOOD JOIST 4'-0" X 6'-0" FLOOR 16 GAGE GALV. DUCT WELDED 1 " PITCH PER FOOT 1 1 /4" X 1 1 /4" ANGLE IRON REMOVABLE COVER WITHOUT USE OF TOOLS EACH LEG (2) 2 1/2" X 3/8" AND THE DOOR SHALL HAVE APPRO D METAL MOTOR COVER WOOD SCREW TO ANCHORED NONCOMBUSTIBLE GASKET MATERIAL W/PLASTER ROOF CEMENT SEAL 10-0" MIN. ANGLE IRON SUPPORT ALL WELDED PROVIDE SCREEN EVAP. COOLER RAIN CAP - (MIN 26 U.S. GAGE GALVANIZED FASTEN COUNTER FLASHING) DUCT ENCLOSURE SHALL BE VENTED z TO EXTERIOR THROUGH WEATHER \ 26 GA. GI=: DUCT OR PROTECTED OPENING r d APPROVAL TYPE N _ ROOF DECK AIR FLEX DUCT 1 - EXISTING JOIST 16 GAGE GALV. DUCT W LDED ' 14"x10" DUCT CLEANOUT WITH TI 3M ALL AROUND DUCT FITTING HINGED DOOR OF STEEL (FIRE RATED TO COMPLY WITH CONSTRl1�TION TO MATCH DUCT MA E AL _ 1 " 26 GA. GL. STRAP BUILDING CODE REQUIREMENT) EXISTING CEIL SUPPORT TO JOIST 1 HR. FIRE CONSTRUCTION' AIR DIFFUSER 6' MAX. 18" WIDE )METAL SHEET WHEN HOOD IS LESS THAN 18" BELOW CEILING EXTEND FIRE RATED CEILING 18" BEYOUND HOOD 3" MIN. HOOD LESS THAN 12" FROM CEILING MUST BE FLASHED SOLID. FIRE DEPT. APPROVAL SHALL BE REQUIRED ON 5/8" DRY WALL TYG p METAL WALL FLASHING FIRE PROTECTION SYSTEM FOR EXH. HOOD & DUCT GREASE FILTER BAFFLE TYPE NFRA 96 SEE NOTE #9 COOKING 6" MIN. ALL OPEN SIDE EQUIPMEN FIN, FLOOR 6 spendable e51gn Inc. Mi'EA&, IMt 615 LAS TUNAS DR. #205 ARCADIA, CA 91007 Tel: (626) 388-4919 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Dependable Design Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Dependable Design Inc. I` O O_ Cf7 z O Q o � z Q ry L l Q LIJ Ln �- 0 > Q Z q J Q m 4" (A DO O Z O d U O J U w D O a_ Date: 1 2/27/2020 Job No: C201 13G Drawn By: JENNY Scale: 1 1 /4"= 1 '-0" Sheet title: EXISTING HOOD DETAIL ELEVATION OF EXH. DUCT, SHAFT NO SCALE (1-1 SECTION OF EXH. HOOD, BLOWER & MAKE-UP AIR NO SCALE ... :. .... l T r... ...v.. -. -. a .:I r -r.N I. r... : ,. -: - .i . , r 4 1 I �I����I���mi :I -:1 I I. l r: t i. r.. i ': i ". P k ,... :. ,. i' I i ; ".'... �. I, .�„'.".,.`�" ;. I _K. r I I.F.. I :,:I a r:.... ,:. a ,. 1 �. L. r:.. ,.. dl r.,r, LI.:. .. i ,. r t ,. ,,:. :: I ., _,: If f I��I , h�hl 1.. ,.b.. ,1. .r ,. I I �rl.. r. I .� I I'. :. .. I. a I. .� 1. nfl �i,. I a,.,, ,, r �. .,.d .I 41t1. f. i., 61 .1:,1:., t. :r,. .. .:r. ,. ,:. ,...Ir. .. I I _lif"T7 , I P .:..: r l , : _ I„ .r :. 1::: „[l a. 1 1 1 l: l r ,., ...�. . � e..�.. r 1„ly._. ROOF EQUIPMENT SCHEDULE NO. DESCRIPTION MA MAKE-UP AIR "FRIGIKING" EVAPORATIVE AIR COOLER, MODEL FS 450 (OR EQUAI) \_IJ UNIT SHALL DELIVERY 2400 CFM, 0 0.5" SP., 3/4 HP., FAN MOTOR (EXISTING) ELECTRICAL: 115V-10 -60 HZ, UNIT APPROX. WEIGHT: 480 LBS KITCHEN HOOD EXH. FAN. "LAU" SERIES BLOWER, MODEL FGP 18-13A (OR EQUAI) EF UNIT SHALL DELIVERY 2400 CFM, @ 0.5 SP., 1-1/2 HP., FAN MOTOR 1 ELECTRICAL: 208V-10 -60 HZ, UNIT APPROX. WEIGHT: 115 LBS (EXISTING) MA MAKE-UP AIR "FRIGIKING" EVAPORATIVE AIR COOLER, MODEL FS 450 (OR EQUAI) 2 UNIT SHALL DELIVERY 9600 CFM, @ 0.5" SP., 3/4 HP., FAN MOTOR (EXISTING) ELECTRICAL: 115V-10 -60 HZ, UNIT APPROX. WEIGHT: 480 LBS KITCHEN HOOD EXH. FAN. "LAU" SERIES BLOWER, MODEL FGP 18-13A (OR EQUAI) EF UNIT SHALL DELIVERY 9600 CFM, @ 0.5 SP., 1-1/2 HP., FAN MOTOR 2 (EXISTING) ELECTRICAL: 208V-10 -60 HZ, UNIT APPROX. WEIGHT: 115 LBS MA MAKE-UP AIR "FRIGIKING" EVAPORATIVE AIR COOLER, MODEL FS 450 (OR EQUAI) 3 UNIT SHALL DELIVERY 3200 CFM, ® 0.5" SP., 3/4 HP., FAN MOTOR (EXISTING) ELECTRICAL: 115V-10 -60 HZ, UNIT APPROX. WEIGHT: 480 LBS KITCHEN HOOD EXH. FAN. "LAU" SERIES BLOWER, MODEL FGP 18-13A (OR EQUAI) EF UNIT SHALL DELIVERY 3200 CFM, ® 0.5 SP., 1-1/2 HP., FAN MOTOR 3 ELECTRICAL: 208V-10 -60 HZ, UNIT APPROX. WEIGHT: 115 LBS (EXISTING) MA MAKE-UP AIR "FRIGIKING" EVAPORATIVE AIR COOLER, MODEL FS 450 (OR EQUAI) 4 UNIT SHALL DELIVERY 1600 CFM, © 0.5" SP., 3/4 HP., FAN MOTOR ELECTRICAL: 115V-10 -60 HZ, UNIT APPROX. WEIGHT: 480 LBS (EXISTING) KITCHEN HOOD EXH. FAN. "LAU" SERIES BLOWER, MODEL FGP 18-13A (OR EQUAI) EF UNIT SHALL DELIVERY 1600 CFM, @ 0.5 SP., 1-1/2 HP., FAN MOTOR 4 ELECTRICAL: 208V-10 -60 HZ, UNIT APPROX. WEIGHT: 115 LBS (EXISTING) EF (EXISTING) 1 Establishment Name: CHEF TONY DIMSUM Job Address: 1108 S. BALDWIN AVE. ARCADIA, CA 91007 - One set of data sheets for each hood system. 1. Size of hood: 6'-0"X4'-O" (TYPE I HOOD) 2. CFM: 6.0 X 4.0 X 100 = 2400 CFM 3. Size of duct: 12"X16" (1798 FPM) for EACH DUCT 4. Number of grease filters: 6 5. Size and type of grease filters: 20"X20" = 2.25 s.f 6. Rating of each filter. (CFM or FPM): 800 CFM EACH FOR FILTER 7. Make-up air (CFM): 2400 CFM (100% make-up air required to be electrically interconnected to exhaust system). 8. Elevated drawing of hood and cooking equipment shown on this sheet of plans. - Flashing shall extend from hood to floor covering. - Wall surfaces within 18" of all cooking equipment shall be flashed. 9. COOKING EQUIPMENT: CHINESE WOK RANGE 100% MECHANICAL MAKE-UP AIR WITH AN INTERLOCKING SWITCH WILL BE PROVIDED 8'-0" #3 HOODUJI z o CHINESE WOK RANGE 0 a_ - - - icr;0 I i I CONVECTION OVEN I OQ i I V a - r I I DEEP FRYER CHINESE B.B.Q. OVEN STEAMER z DOUBLE STOCK POT STOVE DEEP FRYER S.S. WORK TABLE STEAMER CHINESE WOK RANGE DOUBLE STOCK POT STOVE 100% MECHANICAL MAKE-UP AIR WITH AN INTERLOCKING SWITCH WILL BE PROVIDED UNDER HOOD EQUIPMEiNiff SCALE: 1/4" = V-0" GENERAL NOTES 1) FIRE DEPT. APPROVAL SHALL BE REQUIRED ON FIRE PROTECTION SYSTEM FOR GREASE HOODS AND DUCTS AS REQUIRED BY SECTION 510.0 OF THE 2019 CMC AND AS REQUIRED BY THE FIRE CODE. 2) ALL HOODS REQUIRE A FIRE EXTINGUISHING SYSTEM AND CLEANABLE FILTERS APPROVED BY FIRE DEPT. 3) GREASE HOOD EXHAUST FAN AND MAKE-UP AIR UNITS SHALL BE ELECTRICALLY INTERLOCKED. 4) DUCT ENCLOSURE SHALL BE VENTED TO EXTERIOR THROUGH WEATHER PROTECTED OPENING. 5) ADD NOTE ON DRAW "G: ' AUTOMATIC EXTINGVISHING SYSTEM' FOR DEEP FRYER. INSTALLATION SHALL BE SUBMITTED IN TRIPLICATE FOR APPROVAL TO THE ENGINEERING UNIT FIRE DEPT. 6) PROVIDE POWER AND WATER FOR EVAPORATIVE COOLER ON ROOF (MAKE-UP AIR.) 7) FIRE PROTECTIVE SYSTEM & MAKE-UP AIR WHERE REQUIRED BY OTHERS. 8) EXHAUST TERMINATION 10'-0" MIN. FROM ADJACENT BUILDING, ADJACENT PROPERTY LINE, AIR INTAKES OF 10'-0" ABOVE ADJOINING GRADE. 9) EXHAUST HOOD TO HAVE 18" ALKL AROUND CLEARANCE FROM COMBUSTIBLES OR 3" MIN. FROM PROTECTED COMBUSTIBLES. 10) CONTRACTOR TO PROVIDE PERMANENT ACCESS TO ROOF. 11) EXHAUST HOOD DUCT PENETRATION CAN NOT AFFECT THE STRUCTURAL INTEGRITY OF THE ROOF. 12) EXHAUST HOOD MATERIAL MIN. 22 GAGE STEEL. 13) CONTRACTOR SHALL VERIFY WITH EQUIPMENT'S CONTRACTOR FOR THE LOCATION OF EQUIPMENT'S PLUMBING BEFORE ANY WORK WILL BE DONE. 14) ALL WORK MUST COMPLY WITH UMC. EF (EXISTING) 2 Establishment Name: CHEF TONY DIMSUM Job Address: 1108 S. BALDWIN AVE. ARCADIA, CA 91007 - One set of data sheets for each hood system. 1. Size of hood: 24'-0"X4'-O" (TYPE I HOOD) 2. CFM: 24.0 X 4.0 X 100 = 9600 CFM 12.0 X 4.0 X 100 = 4800 CFM (2) 3. Size of duct: (2) 16"X24" (1798 FPM) for EACH DUCT 4. Number of grease filters: 14 5. Size and type of grease filters: 20"X20" = 2,25 s.f 6. Rating of each filter. (CFM or FPM): 686 CFM EACH FOR FILTER 7. Make-up air (CFM): 9600 CFM (100% make-up air required to be electrically interconnected to exhaust system). 8. Elevated drawing of hood and cooking equipment shown on this sheet of plans. - Flashing shall extend from hood to floor covering. - Wall surfaces within 18" of all cooking equipment shall be flashed. 9. COOKING EQUIPMENT: DOUBLE STOCK POT STOVE x3 CHINESE WOK RANGE S.S. WORK TABLE DEEP FRYER x2 STEAMER EF (EXISTING) 3 Establishment Name: CHEF TONY DIMSUM Job Address: 1108 S. BALDWIN AVE. ARCADIA, CA 91007 - One set of data sheets for each hood system. 1. Size of hood: 8'-0"X4'-O" (TYPE I HOOD) 2. CFM: 8.0 X 4.0 X 100 = 3200 CFM 3. Size of duct: 14"X18" (1829 FPM) for EACH DUCT 4. Number of grease filters: 9 5. Size and type of grease filters: 20"X20" = 2.25 s.f 6. Rating of each filter. (CFM or FPM): 356 CFM EACH FOR FILTER 7. Make-up air (CFM): 3200 CFM (100% make-up air required to be electrically interconnected to exhaust system). 8. Elevated drawing of hood and cooking equipment shown on this sheet of plans. - Flashing shall extend from hood to floor covering. - Wall surfaces within 18" of all cooking equipment shall be flashed. 9. COOKING EQUIPMENT: CHINESE B.B.Q. OVEN DEEP FRYER STEAMER EF 6 100% MECHANICAL MAKE-UP AIR WITH AN INTERLOCKING SWITCH WILL BE PROVIDED 8'-0" #3 HOOD AIR VELOCITY: 1829 FPM EXH. DUCT 9"X14" 1W-0 _ I 4r 4 �I. I o 4 EXIT AIR VELOCITY: 1829 FPM EXH. DUCT 14"X18" 10'-0" r -- - - --- MA L 3�------- - EFr--�--------------------- --, I MA 5 2 L--� --- -----------r- �- --- - _ 14-a P , _ .- I EF I 2 I 100% MECHANICAL MAKE- AIR WITH AN INTERLOCKING SWITC LL BE PROVIDED 24'-0" #2 HOOD AIR VELOCITY:1798 FP EXH. DUCT 16"X24" ROOF PLAN SCALE: 1 /4"=1'-0" EF (EXISTING) 4 Establishment Name: CHEF TONY DIMSUM Job Address: 1108 S. BALDWIN AVE. ARCADIA, CA 91007 - One set of data sheets for each hood system. 1. Size of hood: 4'-O"X4'-O" (TYPE 1 HOOD) 2. CFM: 4.0 X 4.0 X 100 = 1600 CFM 3. Size of duct: 9"X14" (1829 FPM) for EACH DUCT 4. Number of grease filters: 2 5. Size and type of grease filters: 20"X20" = 2.25 s.f 6. Rating of each filter. (CFM or FPM): 800 CFM EACH FOR FILTER 7. Make-up air (CFM): 1600 CFM (100% make-up air required to be electrically interconnected to exhaust system). 8. Elevated drawing of hood and cooking equipment shown on this sheet of plans. - Flashing shall extend from hood to floor covering. - Wall surfaces within 18" of all cooking equipment shall be flashed. 9. COOKING EQUIPMENT: CONVECTION OVEN AIR VELOCITY:1798 FPM o EXH. DUCT 12"X16" o Of o <t w o �m i � J o ¢� /EF z �. 1 v� r--� I I o - -I i I I I i I i I MA 1 le s g n n-c 0: gependable (4) 615 LAS TUNAS DR. #205 ARCADIA, CA 91007 Tel: (626) 388-4919 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Dependable Design Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Dependable Design Inc. I,- 0 o_ --� U Q o �„ ry <t W 8d m �. w Q z Z 0 Q W P 1 C) m (!i 00 0 z 0 Q U 0 U W 0 Of I DATE: PEV15ION: I 12/17/20 Health Corrections Date: 1 2/27/2020 Job No: C201 13G Drawn By: JENNY Scale: I /411=1 '-0" Sheet title: EXI5TING ROOF PLAN M =ZAmok im A � GENERAL MOTES 1. ALL WORK SHALL CONFORM TO THE CALIFORNIA PLUMBING CODE LOCAL CODES. INCLUDING INSTALLATION OF ALL REQUIRED CLEANOUTS PER, CPC-2019. 2. CONTRACTORS VERIFY SIZE, DEPTH, LOCATION AND ADEQUACY OF ALL UTILITIES, INCLUDING METER LOCATIONS AND SEWER INVERTS, BEFORE STARTING WORK. 3. ALL PIPING IN FINISHED AREAS SHALL BE CONCEALED WHERE POSSIBLEAND EXPOSED PIPING SHALL BE RUN AS HIGH AS POSSIBLE AND TIGHT TO WALLS. 4. ALL LINES TO BE AWAY FROM BEARING FOOTINGS, OR AS DIRECTED BY STRUCTURAL ENGINEER. 5. INSTALL BACKFLOW PROTECTION DEVICES AS REQUIRED BY LOCAL CODES. 6. INSTALL PRESSURE REDUCING VALVE(S) WITH SHUT-OFF WHERE CITY PRESSURE EXCEEDS 80 PSI. 7. ALL APPLIANCE AND PLUMBING VENTS SHALL BE AT LEAST TEN (10) FEET IN HORIZONTAL DIRECTION OR THREE (3) FEET ABOVE THE OUTSIDE AIR INTAKES FOR HVAC UNITS. 8. SEWER TO BE RUN @ 1 /4" SLOPE. CPC (2019) LARGER LINE MAY BE INSTALLED AT A SLOPE OF NOT LESS THAN 1% WHEN FIRST APPROVED BY THE BUILDING DEPARTMENT, MEETING FU RATING OF 2019 CPC. 9. ALL REQUIRED CLEANOUTS SHALL BE INSTALLED AS PER CPC (2019). 10. ALL EXTERIOR HOSE BIBS SHALL BE PROVIDED WITH NON REMOVABLE BACK FLOW PREVENTION DEVICES AND VACUUM BREAKERS. 11. PRESSURE BOOSTER SYSTEM INSTALLED TO ASSURE REQUIRED PRESSURE AT FIXTURE. INSTALL PRVAT DISCHARGE OF PUMP LINE. 12. PROVIDE SHUT OFF VALVES FOR ALL PLUMBING FIXTURES AND GROUPS. 13. PROVIDE ACCESS PANELS FOR ALL GROUPS OF TOILET FIXTURES. 14. PROVIDE TRAP PRIMERS FOR FLOOR DRAINS. 15. USE DIELECTRIC UNIONS TO CONNECT STEEL AND COPPER OR BRASS PIPES & FIXTURES. PLUMBING LEGEND SYMBOL ABBREVIATION DESCRIPTION ■ = ■ID_ r m r _ r ID INDIRECT DRAIN ABOVE GRADE � GW � GIN GREASE WASTE BELOW GRADE -" -S - ' "- S SANITARY SEWER ABOVE GRADE o ® r ® S ® ® ® s. S SANITARY SEWER BELOW GRADE - - - - - - V- - - - - - - V SANITARY VENT - SCW SCW SOFTENED COLD WATER CW DOMESTIC COLD 'HATER - - FCW FCW FILTERED COLD WATER - - HWS DOMESTIC HOT WATER SUPPLY - - - HWR DOMESTIC HOT WATER RETURN FCO FLOOR CLEANOUT WCO WALL CLEANOUT SOV SHUT OFF VALVE POC POINT OF CONNECTION 0 VTR VENT THROUGH ROOF CD CD CONDENSATE DRAIN -°"------- G-•---•--r-- G NATURAL GAS WC-1 PLUMBING FIXTURE DESIGNATION CONSTRUCTION NOTE R.H. ROUGH -IN HEIGHT A.F.F. ABOVE FINISHED FLOOR G.P.F. GALLON PER FLUSH A.P. ACCESS PANEL G.C. GAS COCK PLUMBING FIXTURE SCHEDULE SYMBOL QUANTITY DESCRIPTION PIPE CONNECTION CW HW S V TRAP WATER FLOW WATER CLOSET, FLOOR MOUNTED, WHITE VITREOUS CHINA, 17 RIM HEIGHT SIPHON JET ELONGATED BOWL, CLOSE -COUPLED FLUSH TANK WC-1 3 @ 1.28 GPF BY AMERICAN STD. 2168.100. 3/4" - 4" 2" INT 1.28 GPF SEAT: OLSONITE #95, OPEN FRONT, LESS COVER. (2.5 FU) (4 FU) 1.28 GALLONS/FLUSH TANK. LAVATORY, COUNTER TOP, WHITE VITREOUS CHINA, FRONT OVERFLOW, UNDER COUNTER, BY AMERICAN STD. 9482.000, 4" CENTER FAUCET LL- I 3 HOLES. 0.5 GPM 1/2" 1/2" 2" 1 1/2" 1 1/2" FAUCET: SENSOR OPERATED ELECTRONIC FAUCET FOR HOT/COLD (1 FU) (1 FU) 0.5 GPF WATER, BY SLOAN. OPTIMA ETF-600-8-2-P WITH PLUG-IN TRANSFORMER AND ETF-460-A GRID STRAINER. URINAL (HANDICAPPED) UU=1 1 A/S "ALLBROOK"6540.017 WHITE VITREOUS CHINA 0.5 GPF WALL HUNG SIPHON JET URINAL w/FLUSHING RIM, FITTING: SLOAN ROYAL 180 3/4" - 2" 1 1/2" 1 1/2" 0.25 GPF FLOOR DRAIN, CAST IRON BODY, FLASHING COLLAR 6" ROUND NICKEL FD-1 2 BRONZE STRAINER, W/ TRAP PRIMER CONNECTION. BY J.R. SMITH. FIG. - - 2 (2 FU) 1 1/2" 2" 2005YO2A-H-PO50 WITH 2" PIPE OUTLET. FLOOR DRAIN, CAST IRON BODY, FLASHING COLLAR 6" ROUND NICKEL FD-1 1 BRONZE STRAINER, W/ TRAP PRIMER CONNECTION. BY J.R. SMITH. FIG. - 2" (2 FU) 1 1/2" 2" 2005YO2A-H-PO50 WITH 2" PIPE OUTLET. FLOOR SINK, CAST IRON FLANGED WITH ACID RESISTANT COATED INSIDE, ` 3" 1 1/2" 2" FS-1 3 NICKEL BRONZE RIM, SEDIMENT BUCKET, HALF GRATE, 12 1/2" SQUARE, (2 FU) BY J.R. SMITH FIG. 3151Y02-12 WITH 3" PIPE OUTLET FLOOR SINK, CAST IRON FLANGED WITH ACID RESISTANT COATED INSIDE, - 2 1 1/2 2" FS-2 2 NICKEL BRONZE RIM, SEDIMENT BUCKET, HALF GRATE, 12 1/2" SQUARE, (11 FU) BY J.R. SMITH FIG. 3151YO2-12 WITH 2" PIPE OUTLET MOP SINK, FLOOR MOUNTED, 24" x24" MOLDED STONE WITH MINIMUM 10" HIGH SIDES. STAINLESS STEEL DRAIN BODY 3/4" 3/4" 3" 2" 2" 1.2 GPF MS-1 1 INTERNALLY CAST, BY FIAT, MODEL #MSB-2424. (3 FU) (3 FU) FAUCET: CHICAGO FAUCET, MODEL #897 WITH INTEGRAL STOPS IN SHANKS, WALL BRACE, HOSE THREADS, RAIL HOOK, VACUUM BREAKER, ROUGH BRASS FINISH, WITH 3 FEET RUBBER HOSE. HS 2 A/S "FLAT RIM SINK" 7020.207 END OUTLET. FLAT RIM. SINGLE BOWL, 1 /2" 1 /2" 2" 1 1 /2" 2" 0.5 GPF COUNTERTOP SINK, ACID RESISTING SNAMELED CAST IRON. DIMENSION: 18"X12"X5 1/2" FITTING: 8344.111 FAUCET w/TOP BRACE, TOP & VACUUM, (1 FU) BREAKER. PROVIDE 1/2" HW AND CW AT ROUGH -IN HEIGHT 14" A.F.F. 8" OC. 3/4" 3/4" 3" 2" PS 2 PROVIDE BV'S AND EXTEND (2 FU) (2 FU) 1.0 GPF COPPER PIPING TO FAUCET. CONNECT 2" WASTE LINE FROM EACH COMPARTMENT SEPARATELY AND DISCHARGE INTO FLOOR SINK WITH AIR GAP, 2CS 1 FURNISHED BY OWNER 1/2" 1/2" (22FU) 1 1 /2" 2" 0.5 GPF 3CS-1 1 FURNISHED BY OWNER 3/4" 3/4" 3" 2" 2" 1.8 GPF (3 FU) (3 FU) PIPE MATERIAL SCHEDULE SERVICE PIPE FITTINGS LOCATION WASTE & ABOVE GRADE VENT CAST IRON NO HUB CAST IRON NO HUB BELOW GRADE OR ABS OR ABS ABS ONLY FOR BELOW GRADE STORM CAST IRON NO HUB CAST IRON NO HUB ABOVE GRADE DRAIN BELOW GRADE HOT AND COLD WATER COPPER TYPE 1" HARD DRAWN WROUGHT COPPER ABOVE GRADE COLD WATER COPPER TYPE "L" HARD DRAWN WROUGHT COPPER BELOW GRADE INDIRECT WASTE COPPER TYPE "M" HARD DRAWN WROUGHT COOPER ABOVE GRADE CONDENSATE DRAIN GAS BLACK STEEL BLACK STEEL ABOVE GRADE SCHEDULE 40 MALLEABLE IRON EXISTING WATER, HEATER: GLASS -LINED, TANK -TYPE COMMERCIAL GAS WATER HEATER SHALL HAVE 100 GALLONS STORAGE CAPACITY 120,000 BTU/HR GAS INPUT, 80 % THERMAL EFFICIENCY @ RECOVERY RATED OF 105 GPH AT 100 TEMPERATURE RISE. WATER HEATER SHALL HAVE A MAXIMUM WORKING PRESSURE OF 150 PSI. COMPLETE WITH ASME TEMP & PRESSURE RELIEF VALVE. BY "BRADFORD WHITE", MODEL: "BRADFORD WHITE" UCGlOOH2703N (EXISTING) PROVIDE ROUND SECURED NICKEL BRONZE ADJUSTABLE TOP WITH "CO" CAST IN COVER. PROVIDE CLEANOUT TOP WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET 2" VENT IN WALL THREE COMPARTMENT SINK MARKER, RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS). PROVIDE PLASTIC PLUG IN CAST IRON BODY. CLEAN THE TOP OF EXPOSED FCO AFTER INSTALLATION. MEMBRANE CLAM FLOOR SLAB ON GRADE V 4 AS REQUIRED FOR SAME SI4f AS SEWER DEPTH OF SEWER �- UP TO 4 MAXIMUM. 2"C0--\ 1-1/2" 1-1/2"- HUB AND SPIGOT LONG SWEEP ELBOW AT CAST IRON PIPE -p END OR TURN OF RUN. BELOW FLOOR. 2" COMBINATION WYE AND SANITARY OR STORM EIGHTH BEND IN RUN. 2" FS-1 F.F. 1-1/2"AIR GA F.F. SEWER LINE -� ENTER TOP OF PIPE. DIRECTION 2"TRAP PRIMER INLET- OF FLOW 3" 2-5G GREASE TRAP E- LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS 3" WASTE ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD OF PIPE GREATER THAN 45 DEGREES, AT 50' INTERVALS TO MAIN SEWER LINE CONDITIONS OR MEET LOCAL CODE REQUIREMENTS. USE TYPE L ON STRAIGHT RUNS, AND WHERE SHOWN ON PLANS. COPPER TUBING FOR INDIRECT WASTE PIPE, FITINGS AND PROVIDE BACKFILL PER ARCHITECTURAL SPECIFICATIONS. CONNECTORS. LOCATE CLEANOUTS WHERE THERE IS 18" CLEAR AROUND. CONSULT LOCAL CODES FOR OTHER FCO REQUIREMENTS. 3 COMPARTMENT SINK NOT TO SCALE 1 FLOOR CLEANOUT NOT TO SCALE( D2 PROVIDE AN INDIVIDUAL VENT ON ALL FLOOR DRAINS. INSTALL VENT IN PARTITION OR CHASE WHERE SHOWN ON PLAN. HORIZONTAL VENT BELOW FLOOR IS NOT PERMITTED. IF FLOOR DRAIN/SINK IS MORE THAN 5' ON A 2" WASTE OR 6' ON A 3" WASTE FROM THE PARTITION, PROVIDE A TRAP AND WASTE LINE TWO PIPE SIZES LARGER THAN THE DRAIN/SINK OUTLET, WITH A REDUCER ON THE TRAP INLET, AND VENT WITHIN 15 FEET. DRILL HOLE IN SIDE OF COOLER OTHER VENTING METHODS MAY BE USED IF APPROVED BY LOCAL CODE. AND PROVIDE CONCRETE FLOOR SILICONE SEAL AROUND PIPE ' d REDUCING TRAP MEMBRANE CLAMP- PENETRATION. � 3/4" DX COIL ING COLLAR AND SEEPAGE PAN. PROVIDE TRAP CO _ O� COORDINATE AT BOTTOM OF MAXIMUM TAILPIECE ZEMNLARGED ROUTING OF RISER AND DIS- PROVIDE CLEANOUT DRAIN WITH 15' WHERE LENGTH IS 2 FEET. CHARGE INTO IN TURNS AND ENDS SHELVING IN FLOOR DRAIN OF PIPE. WALK-IN COOLER WASTE SLOPE WASTE AT OR FLOOR SINK LINE IS USED AS A TWO PERCENT. WITH AIR GAP MAKE CONNECTION COMBINATION WASTE OF TWICE PIPE TO COOLER AND VENT SYSTEM. DIAMETER. PROVIDE TRAP PRIMER IF RE- QUIRED BY LOCAL AUTHORITIES. MAXIMUM 5' ON 2" WALK-IN COOLER FLOOR-\ �or WALK-IN FREEZER OTHERWISE DEEP -SEAL P-TRAP. WASTE OR 6' ON 3". LOCATE FLOOR DRAIN/SINK WHERE SHOWN ON DIMENSIONED ARCHITEC- TURAL PLAN. IF FLOOR STRUCTURE INTERFERES WITH FLOOR SINK, MOVE SIDEWAYS IF POSSIBLE, OTHERWISE MOVE BACK. ALWAYS LOCATE WHERE EASILY ACCESSIBLE, BUT NOT IN FOOT TRAFFIC. IF SITUATION INSTALL PIPE AS HIGH AS POSSIBLE, ANCHOR TO WALL OF COL R �M IS FLOOR SLAB ON GRADE, PROVIDE BACKFILL PER SPECIFICATIONS. WITH SUPPORTS AT MAXIMUM SIX FOOT CENTERS. USE TYPE IF CONCRETE FLOOR IS NOT EXISTING, SET DRAIN IN PLACE AND POUR HARD COPPER TUBE AND FITTINGS WITH LEAD-FREE SOLDER AROUND IT. IF CONCRETE FLOOR IS EXISTING, SAW CUT OR CORE DRILL JOINTS. SLOPE HORIZONTAL PIPE AT MINIMUM TWO PERCENT. IT. SET DRAIN BODY IN PLACE AND POUR AROUND IT. RECESS TOP OF REFER TO LOCAL CODE FOR INDIRECT DRAIN REQUIREMENTS. FLOOR SINKS 1/2" BELOW FLOOR SURFACE AND SLOPE FLOOR TO IT. DO NOT RECESS TOP OF FLOOR DRAINS. IF SITUATION IS FLOOR NOT ON GRADE, REFER TO "FLOOR PENETRATION" DETAIL FOR VENTS. FLOOR DRAIN/SINK NOTTO SCALE WALK-IN BOX CONDENS.DRAIN NOT TO SCALE MIN. 12" FROM ANY VERTICAL SURFACE. MIN. LOFT FROM, OR MIN. 3FT ABV ANY BLDG OUTSIDE AIR INTAKE. PER IPC, -� 3/4' H.W. TO SYSTEM (SET ® 140F) 3/4' C.W. TO HEATER THERMAL EXPANSION TANK, BY THERM-X-TROL, MODEL ST-12. LEAD SLEEVE EMBED - SUPPORT TANK FROM STRUCTURAL 4" FLANGE MEMBER 6" vIIN. G 4" AROUND BUILT-UP ROOF :i :r;.. �• 3/4. NN 5' FLUE VENT UP OFFSET IN CEILING SPACE AND THRU ROOF, SEE DETAIL 16/P-6 PLYWOOD ROOF SHEATHING SLEEVE FLANGE SET IN THERMOMETER I DOWNDRAFT DNERTER PLASTIC CEMENT AND NAILED 03 O.C. b LINE SIZE P&T RELIEF VALVE VENT PIPE, SEE PLAN FOR SIZES STRAP WATER HEATER TO WALL WITH 1 1/2', 18 GA VENT PIPE THROUGH ROOF DETAIL NOT TO SCALE STEEL STRAP ANCHOR TO BLDG STUDS WITH ER LAG SCREWS. STRAP @UPPER 1/3 AND LOWER 1/3 OF TANK D WATER HEATER STUD WALL 3/4' DRAIN TO MOP SINK 1/2" BALL VALVE CW PIPE G ON WALL TRAP PRIMER SECURE TO STUDS CMV WALL 3/8' NUT & BOLT WITH WASHER (TYP) PROVIDE WALL ACCESS GAS PRESSURE REGULATOR UNION 1/2" GWD SEAL WATERTIGHT On, DRAIN HOSE 8180 FLR.DR. FIN. FLOOR GAS COCK DIRT LEG MINIMUM 6" HIGH MOUNTING PLATFORM, TP FLEXIBLE CONNECTOR BY G.C. 1/2 BELOW 1 /2" CW TO TRAP CONNECT FLOOR NOTE: 1. WATER HEATER PROVIDE T&P VALVE TO OUTSIDE OF THE BUILDING. AS REQ'D 2. WATER HEATER VENT HAS TO EXTEND V-0" ABOVE PARAPET WALL. 3. ALL VENT PIPES SHALL RUN MIN, 10'-0' AWAY FROM ALL INTAKE AIR MACHINE OR RESOURCE. TRAP PRIMER DETAIL NOT TO SCALE WATER HEATER MTG. DETAIL NOT TO SCALE 7 ependable esin Inc. =i1mall"IV, T`1117__::-_-­ - 615 LAS TUNAS DR. #205 ARCADIA, CA 91007 Tel: (626) 388-4919 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Dependable Design Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Dependable Design Inc. I,- 0 O rn U 0 d z U < in 0 m cl� 0 > z UJ z C) m W 0 Ui .d. e0 O O d U O F- U w O Of CL Date: 1 1 /23/2020 Job No: C201 1 3G Design By: Drawn By: J.A. Scale: 1 /4"= 1 '-0" Sheet title: PLUMBING NOTES $ DETAIL5 Sheet EXISTING NO CHANGE' COLD/HOT WATER & GAS PLAN SCALE: 1 /4"=1'-0" 11 1FU) 4"S(4 wt-rrE--- ( 4"S(4FU) is WOMF-4"S(39FU) 1 1 F1 I i wl �k�kIRE LOCK ROOM ol, o i FU) # 1 rv----- 2FU _ 12'S(2FU) 4"S($FU)T2. SLOP S� OM I I i 4"S U) -- �WC! /I \ 4FU ' :. OM 3"S(29FU) DINING AREA (EXISTING) — �i ?NFU; -- ------ �_--__�. -_ 2" U 3 W(4FIJ I I 1 2% SLOPE _ �E + T —� 26FUT i bi —I 3"S(26F� — -1 N LJ ----- �--J IkIT HEN REMAIN E"W�3"w6FU) -STING) I 1 FU /; FU I Y 3 9FU �"(2FU) LOP �I FS 2FU CUSTOMER AREA FS 2FU EXISTING NO CHANGE WASTE/VENT PLAN SCALE: 1 /4"=1'-0" NOTE: TO STREET PUBLIC SEWER W/LATERAL CONNECTION. CONTRACTOR TO FIELD VERIFY THE EXACT POINT OF CONNECTION. 13„ 1�FU) I (1: 3' 11 FU)' FD I 2FU I 2"(2FU) 2"(2FU)Cl- IV) N I I � T dependable gesign Inc. 615 LAS TUNAS DR. #205 ARCADIA, CA 91007 Tel: (626) 388-4919 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Dependable Design Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Dependable Design Inc. 0 0 z O � Q f- C/ a LL1 G 0 Of Q 2 W _ 0 in � Z m O > �. Q Z V— Z L.IJ = Q U m 00 0 z 0 Q U 0 J H U W 0 Q�pFESS/pN J ASO,�, c�< co w No. C 40169 Exp.9-30-22 C,f,�I � Of Date: 1 1 /23/2020 Job No: C201 1 36 Drawn By: JENNY Scale: 1 /4"= I '-0" Sheet title: PLUMBING FLOOR PLAN P=2