HomeMy WebLinkAboutPlans(E) 1-STORY S.F.D. REMODEL & ADDITION & 2ND FLOOR ADDITION (N) 4' HIGH BLOCK WALL (N) AUTOMATIC GATE (N) AUTOMATIC GATE PR O P E R T Y L I N E 2 2 0 . 0 0 ' PROPERTY LINE 119.99' PROPERTY LINE 120.00' AD J A C E N T P R O P E R T Y PR O P E R T Y L I N E 2 2 0 . 0 1 ' (N) POOL W/ POOL COVER (N) MULTI-SPORT COURT (VERSA COURT OR SIMILAR ON CONCRETE ) 1S T F L O O R S E T B A C K 93 ' - 3 1 / 2 " 1ST FLOOR SETBACK 20' - 1"82' - 0 1/2" 1ST FLOOR SETBACK 17' - 6" 85 ' - 0 1 / 2 " 5' - 0 " AD J A C E N T P R O P E R T Y 45' - 11"10' - 0" (N) GAZEBO (N) SPA MICHILLINDA AVE 5' 3' REMOVE (E) POOL EQUIPMENT REMOVE (E) POOL EQUIPMENT ENCLOSURE DOOR (N) GRAVEL TO MATCH (E) (E) HEDGES (E ) H E D G E S (N) TRAVERTINE STONE (N) TRAVERTINE STONE (N) CONCRETE HARDSCAPE 2,571 SQ.FT. (39.49% HARDSCAPE AT FRONT YARD) 6,510 SQ. FT. FRONT YARD AREA (40% MAX.) (N) GRAVEL (E) LANDSCAPE (E ) L A N D S C A P E (N) WATER FEATURE 6' MAX. HEIGHT (N) SECONDARY POWER POLE 14 ' - 0 " 12' - 0" (N) 5' TO 6' MAX. ALUMINUM FENCE PER POOL STANDARDS (N) 5' TO 6' MAX. ALUMINUM GATE PER POOL STANDARDS (SELF- CLOSING/SELF- LATCHING) (N) COVERED PORCH (N) 3:12(N) 3:12 (N ) 3: 1 2 (N) SLIDE 6' MAX. HEIGHT (N) BAJA SHELF (N) 24" OAK TREE (N) 24" OAK TREE (N) GRAVEL (E) LANDSCAPE 1S T F L O O R S E T B A C K 54 ' - 3 " 72 ' - 5 1 / 2 " 2ND FLOOR SETBACK 35' - 5 1/2"59' - 2" 2ND FLOOR SETBACK 25' - 0" 36' - 0"15' - 0" (N) 3:12 (N ) 3: 1 2 (N) 3:12 (N) 3:12 (N ) 3: 1 2 (N) 3:12 (N ) 3: 1 2 (N ) 3: 1 2 (N) 3:12(N) 3:12 (N ) 3: 1 2 (N) 3:12 (N) 3:12 (N ) 3: 1 2 (N) 3:12 (N) 3:12 (N ) 3: 1 2 10' - 0" 11' - 11" 4' - 0" 15' - 0" (N) A/C (N) A/C (N) TANKLESS W/H (N) TANKLESS W/H 6' - 0" 14' - 0 1/2" (N) POOL EQUIPMENT 6' MAX. HEIGHT 10 ' - 0 " 10 ' - 0 " (N) 2' MAX. RET. WALL 10' - 5" 14' - 10 1/2" (N) 5' TO 6' MAX. ALUMINUM FENCE PER POOL STANDARDS 30 ' - 0 " 18 ' - 1 " ALL EXTERIOR DOORS WITH DIRECT ACCESS TO POOL TO BE PROVIDED WITH ALARM PER POOL STANDARDS SPORTS COURT LED LIGHT SPORTS COURT LED LIGHT 25' - 0" 2N D F L O O R S E T B A C K 71 ' - 4 " 2N D F L O O R S E T B A C K 10 4 ' - 0 1 / 2 " 78 ' - 0 " 6' - 0 " 6' - 0 1 / 2 " 15' - 0" 4' - 9 " 10' - 0"5' - 0" 12 ' - 4 " 10 ' - 7 " Scale Project number Date Drawn by Checked by GENERAL NOTES APPLICABLE CODES: 2022 CALIFORNIA BUILIDNG CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ELECTRICAL CORE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE FLOW RATES: FIXTURE TYPE MAXIMUM ALLOWABLE FLOW RATE SHOWERHEADS 1.8 GPM @ 80 PSI LAVATURY FAUCETS, RESIDENTIAL 1.2 GPM @ 60 PSI KITCHEN FAUCETS 1.5 GPM @ 60 PSI METERING FAUCETS 0.2 GALLONS/CYCLE URINALS 0.125 GALLONS/FLUSH ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS. IN THE EVENT OF DISCREPANCIES AND/OR CONFLICTS BETW EEN PLANS AND FIELD CONDITIONS CONTRACTOR MUST IMMEDIATELY NOTIFY THE DESIGNER, IN WRITING. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW ALL CONSTRUCTION DOCUMENTS INCLUDING , BUT NOT LIMITED TO, ALL OF THE DRAWINGS AND SPECIFICATIONS ASSOCIATED WITH THE PROJECT PRIOR TO THE INITIATION AND COMMENCEMENT OF CONSTRUCTION. SHOULD THE CONTRACTOR FIND A DISCREPANCY, IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO NOTIFY THE PROJECT DESIGNER, IN WRITING, PRIOR TO THE START OF CONSTRUCTION PRIOR TO STARTING CONSTRUCTION,THE CONTRACTORIS RESPONSIBLETO ENSURE THAT ALL REQUIRED PERMITS AND APPROVALS HAVE BEEN OBTAINED. CONTRACTOR MUST HAVE COPIES OF ALL PERMITS AND APPROVALS ON SITE AT ALL TIMES. THE OWNER/CONTRACTOR MUST BE FAMILIAR WITH AND RESPONSIBLE FOR THE PROCUREMENT OF ALL DOCUMENTS AND CERTIFICATIONS REQUIRED FOR THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY. ALL WORK MUST BE PERFORMED IN ACCORDANCEWITH THESE PLANS,. SPECIFICATIONS AND CONDITIONSOF APPROVAL,AND ALL APPLICABLE REQUIREMENTS, RULES, REGULATIONS, STATUTORY REQUIREMENTS,CODES, LAWS AND STANDARDS OF ALL GOVERNMENTAL ENTITIES WITH JURISDICTION OVER THIS PROJECT OUTLETS ALONG WALL COUNTER SPACE, ISLAND AND PENINSULA COUNTER SPACE IN KITCHENS SHALL HAVE A MAXIMUM SPACING OF 48". (210-52 NEC) ALL NEW LIGHTING SHALL BE FROM AN ENERGY HIGH EFFICACYLIGHT SOURCE (E.G. FLUORESCENT LAMP).(T-24, SEC. 150(K)) EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN AVERAGE ILLUMINATION OF 6 FOOT-CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30 INCHES ABOVE THE FLOOR LEVEL. (R303.1) A COPY OF THE EVALUATION REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE. PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR TO AN APPROVED SEWAGE DISPOSAL SYSTEM (R306.3) KITCHEN SINKS, LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND WASHING MACHINE OUTLETS SHALL BE PROVIDED WITH HOT AND COLD WATER AND CONNECTED TO AN APPROVED WATER SUPPLY (R306.4) A MAINTENANCE OF VEHICLE LIFT SYSTEM (2-LEVELS OR MORE) AFFIDAVIT”SHALL BE APPROVED AND RECORDED PRIOR TO ISSUING A BUILDING PERMIT. A MINIMUM OF 65 PERCENT OF THE NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTESHALL BE RECYCLE AND/OR SALVAGE FOR REUSE IN ACCORDANCE WITH CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 4 DIVISION 4.4. (R334) FINISH MATERIALS INCLUDING ADHESIVES, SEALANTS, CAULKS, PAINTS AND COATING, AEROSOL PAINTS AND SYSTEMS AND COMPOSITE WOOD PRODUCTS SHALL MEET THE VOLATILE ORGANIC COMPOUND (VOC) EMISSION LIMITS IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 4 DIVISION 4.5. (R340) WHEN A VAPOR RETARDER IS REQUIRED, A CAPILLARY BREAK SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 4, DIVISION 4.5. (R506.2.3.1)16.ANNULAR SPACE AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN BOTTOM/SOLE PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 4, DIVISION 4.4. (R602.3.4.1) THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. AN APPROVED SEISMIC GAS SHUT OFF VALVE OR EXCESS FLOW SHUT OFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN-STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. (PER ORDINANCE 170,158 AND 180,670) SEPARATE PLUMBING PERMIT IS REQUIRED.\ PROVIDE ULTRA-FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. PROVIDE (70) (72) INCH HIGH NON-ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED SHATTER-RESISTANT MATERIALS FOR SHOWER ENCLOSURE. (1210.2.3, 2406.4.5, R307.2, R308.4) VICINITY MAP BLOCK MAP LEGAL DESCRIPTION SHEET INDEX OWNER'S INFO DESIGNER PROJECT INFO SCOPE OF WORK INTELECTUAL PROPERTY NOTICE: THESE DRAWINGS ARE EXCLUSIVE PROPERTY OF MILS BEAM DESIGN AND SHALL NOT BE REPRODUCED/USED IN WHOLE OR PARTIALLY WITHOUT THE WRITTEN AGREEMENT OF MILS BEAM DESIGN RF A CA L C ' S TITLE 24STRUCTURAL ENGINEER PR O J E C T D I R E C T O R Y LO T CO V E R A G E FIRE PLANS DEFFERED SUBMITTAL 3/32" = 1'-0" A-0 SITE PLAN/GENERAL NOTES/INFO 245 MI C H I L L I N D A H O U S E 04.17.23 MJ Checker 13 5 4 M I C H I L L I N D A A V E , A R C A D I A , C A 9 1 0 0 6 A-0 SITE PLAN/GENERAL NOTES/INFO A-0.1 EXISTING SITE PLAN A-1 EXISTING/DEMO 1ST FLOOR PLAN A-2 PROPOSED 1ST FLOOR PLAN A-3 PROPOSED 2ND FLOOR PLAN & GAZEBO A-4 ROOF PLAN A-5 ELEVATIONS A-6 ELEVATIONS A-7 ELEVATIONS APN: 5769-001-004 Situs Address: 1354 MICHILLINDA AVE ARCADIA CA 91006-1921 Legal Description (for assessment purposes): TRACT # 11204 LOT 1 Mils Beam Design 2130 Colby Ave, #6 Los Angeles, CA 90025 t. (310) 866-5630 milsbeamdesign@gmail.com LOT AREA:26,400 SQ.FT. (E) S.F.D. AREA PER ASSESSOR'S:3,273 SQ.FT. (E) BUILDING HEIGHT:14'-0" (N) BUILDING HEIGHT:30'-0" (N) # OF STORIES 2 ZONE: R-O YEAR BUILT:1954 OCCUPANCY: R-2 EXISTING FIRE SPRINKLER:NO LOT AREA:26,400 SQ.FT. (E) 1ST FLOOR (EXCLUDING GARAGE & STORAGE) TO REMAIN 3,020 SQ.FT. PORTION OF (E) 1ST FLOOR TO BE REMOVED 47 SQ. FT. (E) GARAGE & STORAGE TO BE REMOVED 479 SQ.FT. (N) 1ST FLOOR ADDITION INCLUDING GARAGE:1,379 SQ.FT. (N) 1ST FLOOR COVERED PORCH:82 SQ.FT. (N) 2ND FLOOR ADDITION:2,186 SQ.FT. (N) 2ND FLOOR COVERED BALCONY:167 SQ.FT. + 55 SQ.FT. TOTAL 2-STORY HOUSE AREA (INCLUDING GARAGE): 6,889 SQ.FT. (N) 1ST FLOOR GARAGE 736 SQ.FT. TOTAL 2-STORY HOUSE AREA (EXCLUDING GARAGE): 6,153 SQ.FT. (N) GAZEBO 120 SQ.FT. TOTAL FAR AREA:7,009 SQ.FT. MAX. FAR 9,600 SQ.FT. 1. EXISTING HOUSE REMODEL & ADDITION 2. NEW POOL W/ SPA 3. NEW GAZEBO 4. NEW MULTI-SPORT COURT 3/32" = 1'-0"1 Site/Roof Plan A-8 SECTIONS A-9 DETAILS A-10 3D RENDERS L-0 EXISTING LANDSCAPE PLAN L-1 PROPOSED LANDSCAPE PLAN BUILDING FOOTPRINT AREA 4,644 SQ.FT. GAZEBO FOOTPRINT AREA 120 SQ.FT. TOTAL FOOTPRINT AREA 4,764 SQ.FT. MAX LOT COVERAGE 9,240 SQ.FT. No. Description Date 1 Revision 1 Date 1 PR O P E R T Y L I N E 2 2 0 . 0 0 ' MICHILLINDA AVE (E) DRIVEWAY (E) 1-STORY S.F.D. (E) ELECTRICAL POWER POLE (E) DRIVEWAY PR O P E R T Y L I N E 2 2 0 . 0 1 ' PROPERTY LINE 119.99' PROPERTY LINE 120.00' (E) POOL (E) SPA 22. (E) PALM TREE 23. (E) PALM TREE 1. OAK TREE 2. OAK TREE 6. OAK TREE 7. OAK TREE 8. OAK TREE 3. OAK TREE ø 1 ' - 0 " ø 1 ' - 0 " 4. OAK TREE ø 1' - 1" ø 0' - 8" ø 0' - 8"ø 0' - 7" 5. OAK TREE ø 1' - 8" 2 ' - 0 " 4' - 3" ø 0 ' - 3 " ø 1 ' - 0 " ø 0 ' - 8 " ø 0 ' - 1 0 "ø 1 ' - 1 "ø 1 ' - 0 " ø 0' - 10" ø 0 ' - 4 " ø 0' - 4 1/2" 1 ' - 1 " ø 1 ' - 8 " ø 0 ' - 9 " ø 2 ' - 2 " ø 0 ' - 4 " 0' - 9 1/2" ø 0 ' - 4 " ø 0 ' - 4 " 9. 10. 11. 12. 13. 14. OAK TREE 15. OAK TREE 16. 17. OAK TREE 18. 19. 20. 24.25. 26. 27.28.29. 21. 89 ' - 5 " SE T B A C K 71 ' - 8 " SETBACK 20' - 1"82' - 0 1/2" SETBACK 17' - 6" AD J A C E N T P R O P E R T Y AD J A C E N T P R O P E R T Y DN DN ø 1 ' - 7 "ø 0' - 8" AD J A C E N T L O T S E T B A C K 56 ' - 0 " AD J A C E N T L O T S E T B A C K 52 ' - 6 " 58 ' - 1 1 1 / 2 " Scale Project number Date Drawn by Checked by 3/32" = 1'-0" A-0.1 EXISTING SITE PLAN 245 MI C H I L L I N D A H O U S E 04.15.23 MJ Checker 13 5 4 M I C H I L L I N D A A V E , A R C A D I A , C A 9 1 0 0 6 3/32" = 1'-0"1 Existing Site Plan No. Description Date 1 Revision 1 Date 1 NEW REQUIRED FRONT SETBACK AT 1354 MICHILLINDA AVE: AVERAGE SETBACK OF ADJACENT PROPERTIES (56'+52.5')/2 = 54.25' Grade Level 0' -0" (N) STUCCO 2nd Floor TP 23' -6 1/2" (N) Roof 30' -0" (N) 1st Floor TP 11' -8 1/4" (N) FAUX STONE (N) STUCCO 224 223 224 218 350 218 387 3 :1 2 3:12 210 (N) ROOF (N) ROOF(N) ROOF 14 ' - 0 " (N) DARK GRAY ALUMINUM TRIM (N) STUCCO 2nd Floor TP 23' -6 1/2" (N) Roof 30' -0" (N) FAUX STONE(N) STUCCO (N) STUCCO 214 222 390 388 388 210 210 225 225 394 394 394 210 200 394 200 (N) ROOF (N) ROOF (N) ROOF(N) DARK GRAY ALUMINUM TRIM (N) FAUX STONE Scale Project number Date Drawn by Checked by 1/4" = 1'-0" A-5 ELEVATIONS 245 MI C H I L L I N D A H O U S E 04.15.23 Author Checker 13 5 4 M I C H I L L I N D A A V E , A R C A D I A , C A 9 1 0 0 6 No. Description Date 1/4" = 1'-0"1 West 1/4" = 1'-0"2 East 1/4" = 1'-0"3 West - Gazebo STUCCO FINISH FI N I S H C O L O R B O A R D LA HABRA EGG SHELL OR SIMILAR CONCRETE TILE ROOF WESTLAKE ROYAL ROOFING SOLUTIONS / SHADOW BLACK CRRC: 0942-0196, REF: 0.11, EMI: 91, SRI: 8 FAUX STONE GENSTONE / VANILLA BEAN PANEL Grade Level 0' -0" 2nd Floor FF 12' -8 1/4" 2nd Floor TP 23' -6 1/2" (N) Roof 30' -0" (N) 1st Floor TP 11' -8 1/4" (N) STUCCO 226 227 208 227 225 228 228 228 228 (N) ROOF (N) ROOF (N) ROOF 3:12 225 Adjecent Property North Ground Floor I 5' -4" (N) FAUX STONE Grade Level 0' -0" 2nd Floor FF 12' -8 1/4" 2nd Floor TP 23' -6 1/2" (N) Roof 30' -0" (N) 1st Floor TP 11' -8 1/4" (N) FAUX STONE (N) FAUX STONE (N) STUCCO 201 201 222 222 157 (N) ROOF (N) ROOF (N) ROOF (N) ROOF 3 :1 2 209 209 Adjecent Property North Ground Floor I 5' -4" 201 201 209 209 225 225 Scale Project number Date Drawn by Checked by 1/4" = 1'-0" A-6 ELEVATIONS 245 MI C H I L L I N D A H O U S E 04.15.23 Author Checker 13 5 4 M I C H I L L I N D A A V E , A R C A D I A , C A 9 1 0 0 6 No. Description Date 1/4" = 1'-0"1 South 1/4" = 1'-0"2 North Grade Level 0' -0" (E) Roof 14' -0 9/32" Adjacent Property Ground Floor II -2' -0" 1st Floor FF 0' -10" 1st Floor TP 9' -0" 2nd Floor FF 12' -8 1/4" 2nd Floor TP 23' -6 1/2" (N) Roof 30' -0" (N) 1st Floor TP 11' -8 1/4" Scale Project number Date Drawn by Checked by 1/4" = 1'-0" A-7 ELEVATIONS 245 MI C H I L L I N D A H O U S E 04.15.23 Author Checker 13 5 4 M I C H I L L I N D A A V E , A R C A D I A , C A 9 1 0 0 6 No. Description Date 1/4" = 1'-0"1 Front Fence Grade Level 0' -0" (E) Roof 14' -0 9/32" 1st Floor FF 0' -10" 1st Floor TP 9' -0" 2nd Floor TP 23' -6 1/2" (N) Roof 30' -0" (N) 1st Floor TP 11' -8 1/4" (E) CRAWLSPACE (N) SLAB ON GRADE(E) F.J. (N) F.J. (N) F.J.(N) C.J. (N) R.R.(N) R.R. 3 :1 2 10 ' - 1 0 1 / 2 " 10 ' - 1 0 1 / 2 " Grade Level 0' -0" (E) Roof 14' -0 9/32" 1st Floor FF 0' -10" 1st Floor TP 9' -0" 2nd Floor FF 12' -8 1/4" 2nd Floor TP 23' -6 1/2" (N) Roof 30' -0" (N) 1st Floor TP 11' -8 1/4" (E) CRAWLSPACE (N) SLAB ON GRADE (E) F.J. (N) F.J. (N) C.J. (N) R.R.(N) R.R. 10 ' - 1 0 1 / 2 " 10 ' - 1 0 1 / 2 " Scale Project number Date Drawn by Checked by 1/4" = 1'-0" A-8 SECTIONS 245 MI C H I L L I N D A H O U S E 04.15.23 Author Checker 13 5 4 M I C H I L L I N D A A V E , A R C A D I A , C A 9 1 0 0 6 No. Description Date 1/4" = 1'-0"1 Section 1 1/4" = 1'-0"2 Section 2 Scale Project number Date Drawn by Checked by A-10 3D RENDERS 245 MI C H I L L I N D A H O U S E 04.15.23 MJ Checker 13 5 4 M I C H I L L I N D A A V E , A R C A D I A , C A 9 1 0 0 6 No. Description Date 1 Revision 1 Date 1 1 Front View