HomeMy WebLinkAbout7 Las Tunas Dr A - 2022 - TI Paris BaguetteS100
01A
L
L
D
R
A
W
I
N
G
S
A
N
D
W
R
I
T
T
E
N
M
A
T
E
R
I
A
L
A
P
P
E
A
R
I
N
G
H
E
R
E
I
N
C
O
N
S
T
I
T
U
T
E
T
H
E
O
R
I
G
I
N
A
L
A
N
D
U
N
P
U
B
L
I
S
H
E
D
W
O
R
K
O
F
F
T
H
E
S
A
M
E
M
A
Y
N
O
T
B
E
D
U
P
L
I
C
A
T
E
D
,
U
S
E
D
O
R
D
I
S
C
L
O
S
E
D
W
I
T
H
O
U
T
T
H
E
W
R
I
T
T
E
N
C
O
N
S
E
N
T
O
F
T
H
E
H
W
A
N
G
S
T
R
U
C
T
U
R
A
L
E
N
G
I
N
E
E
R
S
I
N
C
.
C
O
P
Y
R
I
G
H
T
A
L
L
R
I
G
H
T
S
R
E
S
E
R
V
E
D
.
DRAWN BY
LAST REVISED
DATE
PROJECT NO.
SHEET TITLE
DRAWING NO.
SHEET:OF:
-
Engineer Seal:
Project :
03
-
-
02/03/2023
R
E
R
LR
S
G
A
E
F
G
E
L
N
O
G
A
WEHDOETSAHN
A
J
T
U
T
E
T
I
UC
L I F
R
O
S
T U
F
R
No. 5592
Exp.06-30-23
CA
IOSSENPRO
N
N
I
IA
E
R
N
3501 Ocean View Blvd.
Glendale, CA 91208
j u n o @ h w a n g s e .c o m
T e l . 2 1 3 ) 2 6 8 -0 9 3 5
StructuralEngineers In c .
Revisions
DESCRIPTIONNO.
GENERAL NOTES
& INFO.
ABBREVIATIONS
&AND@AT
Ø DIAMETERA.B.ANCHOR BOLT
A.C.I.AMERICAN CONCRETE
INSTITUTEA.I.S.C.AMERICAN INSTITUTE OF
STEEL CONSTRUCTION
ALT.ALTERNATEASSN.ASSOCIATIONAPPROX.APPROXIMATELY
ARCH.ARCHITECTURALA.S.T.M.AMERICAN STANDARD FOR
TESTING AND MATERIALS
A.W.S.AMERICAN WELDING SOCIETY
(B), BOT.BOTTOM
BET.BETWEENBFBRACED FRAME
BLDG.BUILDING
BLK.BLOCKBLKGBLOCKING
BM.BEAMB.N.BOUNDARY NAILING
B.S.BOTH SIDES
C CHANNEL OF CAMBER
CANT CANTILEVERCAT.CATALOG
C.B.C.CALIFORNIA BUILDINGCODE
C.I.P.CAST-IN-PLACE CONCRETE
C.J.CONSTRUCTION JOINT ORCEILING JOINT
, CL.CENTERLINE
CLG.CEILING
CLR.CLEARC.M.U.CONCRETE MASONRY UNIT
CO.COMPANYCOL.COLUMN
CONC.CONCRETE
CONST.CONSTRUCTIONCONT.CONTINUOUS
CRIP.CRIPPLECTR.CENTER
CU.FT.CUBIC FEETCU.IN.CUBIC INCH
CU.YD.CUBIC YARD
d b BAR DIAMETER
DBL.DOUBLEDET.DETAILDIA.DIAMETER
DIAG.DIAGONALDIM.DIMENSION
D.L.DEAD LOADDN.DOWN
DO.DITTO
DWG.(S)DRAWING(S)
(E)EXISTINGEA.EACH
EE.EACH END
E.A.EACH FACEE.J.EXPANSION JOINT
EL.ELEVATIONELEV.ELEVATOR
EMBED.EMBEDMENTE.N. EDGE NAILING
ENGR.ENGINEER
EMGRG.ENGINEERINGEQ.EQUAL
EQUIP.EQUIPMENTE.S.EACH SIDE
ETC ET CETERAE.W.EACH WAY
E-W EAST-WEST
EXP.EXPANSIONEXT.EXTERIOR
F.D.FLOOR DRAIN
FDN.FOUNDATION
F.F.FINISH FLOOR
F.G.FINISH GRADE
FIN.FINISHF.J.FLOOR JOIST
F.L.G.FLANGEFL.FLOOR
F.O.FACE OFF.O.C.FACE OF CONCRETE
F.O.M.FACE OF MASONRY
F.O.S.FACE OF STUDF.P.FULL PENETRATION
F.T.FEET OR FOOTFTG.FOOTING
GA.GAUGEGALV.GALVANIZED
G.B.GRADE BEAMGLBGLU-LAM BEAM
GYP. BD.GYPSUM BOARD
(H)HIGH
HDR HEADERHGRHANGER
HORIZ.HORIZONTALH.S.B.HIGH STRENGTH BOLT
HT.HEIGHT
I.C..O.INTERNATIONAL
CONFERENCE OFBUILDING OFFICIALS
I.D.INSIDE DIAMETERI.F. INSIDE FACE
IN.INCH(ES)INFO.INFORMATION
INT.INTERIOR
JT.JOINT
JST.JOIST
K.KIP (1,000 LBS)
K/FT, K/'KIPS PER FOOTKSIKIPS PER SQUARE INCH
(L)LOW
LG.LONG
LIN.LINEARL.F.LIVE LOAD
LONGIT.LONGITUDINALL.S.LAG SCREW
LT.WT.LIGHT WEIGHT
M.B.MACHINE BOLT
M.D.MID-DEPTHMATL.MATERIAL
MAX.MAXIMUM
MECH.MECHANICALMEMB.MEMBRANE
MFR.MANUFACTURERMIN.MINIMUMMISC.MISCELLANEOUS
MTL.METAL
(N)NEW
N.A.NEUTRAL AXISNO., #NUMBER
N-S NORTH-SOUTHN.T.S.NOT TO SCALE
O.C., O/C ON CENTERO.D.OUTSIDE DIAMETER
O.F.OUTSIDE FACEOPNG.OPENING
ORIG.ORIGINAL
PL.PLATE OF PROPERTY LINE
PLYWD.PLYWOODP.S.F., psf POUNDS PER SQUARE FOOT
P.S.I., psi POUNDS PER SQUARE INCHP.T.POST-TENSIONING
R.RADIUSR.D.ROOF DRAIN
REF.REFERENCEREINF.REINFORCE(D) / REINFORCING
REQD.REQUIREDR.R.ROOF RAFTER
S.A.D.SEE ARCHITECTURAL DRAWINGSSCHED.SCHEDULE
SEC.SECTIONSHT.SHEET
SIM.SIMILAR
S.J.SLAB JOINT
S.O.G.SLAB-ON-GRADE
SPESC.SPECIFICATIONSSQ.SQUARE
STAG.SRAGGER(ED)STD.STANDARD
STIFF STIFFENER
ST'L STEEL
STR.STRAIGHT
SYM.SYMMETRICAL
(T)TOPT & B TOP AND BOTTOM
T & G TONGUE AND GROOVE
THK THICKNESS
T.J.TRUSS JOIST
T.O.C.TOP OF CONCRETET.O.F.TOP OF FOOTING
T.O.S.TOP OF SLAB(STEEL)TS STRUCTURAL TUBE
TRANS.TRANSVERSE
TYP.TYPICAL
U.B.C.UNIFORM BUILDING CODEU.N.O.UNLESS NOTED OTHERWISE
VERT.VERTICALVARI.VARIOUS
W/WITH
WD WOOD
W/O WITHOUTW.J.WALL JOINT
W.P.M.WATERPROOF MEMBRANEWT.WEIGHT
W.W.F WELDED WIRE FABRIC
SYMBOLS
SHEET INDEX INFO.
N
01
ICC REPORT #
-ITW RAMSET POWER-ACTUATED FASTERNERS AND CEILING CLIP
ASSEMBLIES ESR-1799
-HILTI SELF-DRILLING AND SELF-PIERCING SCREWS ESR-2196
-HILTI KWIK BOLT TZ CARBON AND STAINLESS STEEL ANCHORS ESR-1917
GRID LINES
NORTH ARROW
TOP OF FLOORELEVATION
EARTH
GRAVEL
MATCHLINE
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
SECTION NUMBER
SHEET NUMBER
ELEVATION NUMBER
SHEET NAME
PLAN NUMBER
PLAN
ELEVATION
SECTION
DETAIL
EL ±0'-0"
# / #-#
# / #-#
#
#
#
#
#
#
P. SHEET NO.SHEET TITLE
1.S100 GENERAL NOTES & INFO.
2.S200 1ST FLOOR WALLS & ROOF FRAMING PLAN
3.S300 DETAILS & SECTION
1.ALL WORK SHALL CONFORM TO THE CBC 2019.
2.THE FOLLOWING NOTES AND ALL OTHER TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS
NOTED OTHERWISE.
3.STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL,
MECHANICAL AND ELECTRICAL DRAWINGS.
4.FRAMING CONDITIONS NOT SPECIFICALLY SHOWN SHALL BE FRAMED SIMILAR TO THE
DETAILS SHOWN FOR THE RESPECTIVE MATERIALS.
5.PROVIDE OPENINGS AND SUPPORTS FOR MECHANICALS EQUIPMENT, DUCTS, PIPING, VENTS
AND ETC., AS REQUIRED. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR
ADDITIONAL OPENINGS AND EQUIPMENT WHICH ARE NOT SHOWN ON STRUCTURAL
DRAWINGS. ALL SUSPENDED EQUIPMENT TO BE PROVIDED WITH APPROVED ALL BRACING.
6.CONTRACTOR MUST CLARIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE COMMENCING
WORK. ARCHITECT SHALL BE INFORMED AND NOTIFIED ANY TYPE OF DISCREPANCIES.
7.NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER THESE GENERAL
NOTES.
8.DESIGN MATERIALS, EQUIPMENT, AND PRODUCTS OTHER THAN THOSE DESCRIBED BELOW
OR INDICATED ON THE DRAWINGS MAY BE CONSIDERED FOR USE. PROVIDED PRIOR TO
APPROVAL IS OBTAINED FROM THE OWNER, ARCHITECT/ENGINEER, AND THE APPLICABLE
GOVERNING CODE AUTHORITY.
9.CONTINUOUS INSPECTION BY A CITY LICENSED DEPUTY INSPECTOR IS REQUIRED FOR ALL
STRUCTURAL CONNECTIONS, FOOTINGS, GRADE BEAMS, AND RETAINING WALLS DURING
INSTALLATION.
10.DESIGN CRITERIA
EARTHQUAKE DESIGN DATA
SEISMIC IMPORTANCE FACTOR (I) : 1.0
RISK CATEGORY : II
MAPPED SPECTRAL RESPONSE ACCELERATIONS
Ss : 1.882g
S1 : 0.631g
SITE CLASS : D
SPECTRAL RESPONSE COEFFICIENTS
SDS : 1.254g
SEISMIC DESIGN CATEGORY : D
GENERAL NOTES
METAL STUDS AND ACCESSORIES
-MEET OR EXCEED MIN. REQUIREMENTS OF FED. SPEC. QQ-S-698 AND FED. SPEC. QQ-S-775d,
FOR THE ITEM AND USE IN-TENDED METAL STUDS:
1.AT INTERNAL METAL STUD PARTITIONS, UNLESS OTHERWISE SHOWN ON THE DRAWINGS,
PROVIDE STANDARD PUNCHED STEEL STUDS OF THE GAGES SHOWN ON THE DRAWINGS,
EITHER HOT-DIP GALVANIZED OR FACTORY PRE-PAINTED.
2.USE ONLY ONE TYPE THROUGHOUT THE WORK, UNLESS OTHERWISE SHOWN ON THE
DRAWINGS OR SPECIFICALLY APPROVED IN ADVANCE BY THE ARCHITECT OR ENGINEER
ACCESSORIES:
PROVIDE ALL ACCESSORIES INCLUDING, BUT NOT NECESSARILY LIMITED TO, TRACKS, CLIPS,
ANCHORS, FASTENING DEVICES, SOUND ATTENUATION PENCIL RODS AND RESILIENT CLIPS,
AND OTHER ACCESSORIES REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, AND
AS RECOMMENDED BY THE MANUFACTURER OF THE STEEL STUDS USED. ALL METAL STUDS
AND SCREWS PROVIDED BY METAL SYSTEM. (I.C.B.O. #4943)
3.ALL SCREWS COMPLY TO ICBO. NER-211.PA
R
I
S
B
A
G
U
E
T
T
E
17
L
A
S
T
U
N
A
S
D
R
.
AR
C
A
D
I
A
,
C
A
9
1
0
0
7
WOOD FRAMES
1.ALL LUMBER TO BE STRESS GRADE, DOUGLAS FIR LARCH(DF), AS SHOWN BELOW PLANS PER
NDS 2018 UNLESS OTHER WISE INDICATE ON
A. JOISTS AND RAFTER : DF #2 GRADE
B. 2"-4" BEAM : DF #1 GRADE
: DF #2 GRADE FOR HEADER
C. 5"x5" LARGER BEAM : DF #1 GRADE
D. STUDS : DF #2 GRADE
E. POST AND COLUMN : DF #1 GRADE
2.MOISTURE CONTENT IN USE WILL BE A MAXIMUM OF 19%.
3.DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS, UNLESS OTHERWISE NOTED, AND ALSO
NAILED TOGETHER WITH 16d NAILS @9" O.C..
4.UNLESS OTHERWISE NOTED ALL NAILING SHALL CONFORM TO THE NAILING SCHEDULE
REQUIRED BY THE LOCAL DEPARTMENT OF THE BUILDING AND SAFETY.
5.UNLESS OTHERWISE INDICATED, RAFTERS AND JOIST SHALL BE SPLICED AT SUPPORTS WITH
A MINIMUM OF 4" OF LAP AND 4-16d NAILS.
6.TOP PLATE OF ALL STUD WALLS SHALL BE 2 PIECES OF 2x4 PLATES. SPLICES TO LAP 4'-0"
MINIMUM AND BE NAILED WITH 12-16d NAILS MINIMUM EACH SIDE OF JOINT.
7.PROVIDE SOLID 2x BLOCKING BETWEEN JOISTS AND RAFTERS AT ALL SUPPORTS. BLOCKING
SHALL BE ONE PIECE AND THE FULL DEPTH OF THE JOIST OR RAFTER.
8.EACH SHEET OF PLYWOOD SHALL BE IDENTIFIED BY A REGISTERED STAMP OR BRAND OF
THE DOUGLAS FIR PLYWOOD ASSOCIATION.
9.WOOD STRUCTURAL PANELS SHALL COMPLY WITH U.S. PRODUCT STANDARDS FOR ITS TYPE
IN PS 1 OR PS 2 AND BE CLASSIFIED AS EXPOSURE 1. AS A MINIMUM ALL WOOD STRUCTURAL
PANELS SHALL BE APA RATED SHEATHING UNLESS NOTED OTHERWISE ON PLANS AND
DETAILS.
10.STRUCTURAL MEMBERS SHALL NOT BE CUT FOR PIPES, ETC. UNLESS SPECIFICALLY
DETAILED.
11.SHEATHING AND SHEAR WALLS SHALL BE INSPECTED AND APPROVED PRIOR TO COVERING.
12.BORED HOLES SHALL NOT BE LOCATED AT THE SAME SECTION OF STUD AS A CUT OR
NOTCH.
13.ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD
SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR
BLOCKED PANEL EDGES.
14.ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED
BOX.
15.BOLT HOLES IN WOOD SHALL BE 1/32" TO 1/16" LARGER THAN THE NOMINAL BOLT DIAMETER.
ALL BOLTS SHALL HAVE STANDARD CUT WASHER UNDER HEAD AND NUT UNLESS
OTHERWISE NOTED.
16.FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT TREATED WOOD SHALL
BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL.
SCALE : 1/4"=1'-0"
1ST. FLOOR WALLS & ROOF FRAMING PLAN 01 S200
1ST. FLOOR
WALLS & ROOF
FRAMING PLAN
02A
L
L
D
R
A
W
I
N
G
S
A
N
D
W
R
I
T
T
E
N
M
A
T
E
R
I
A
L
A
P
P
E
A
R
I
N
G
H
E
R
E
I
N
C
O
N
S
T
I
T
U
T
E
T
H
E
O
R
I
G
I
N
A
L
A
N
D
U
N
P
U
B
L
I
S
H
E
D
W
O
R
K
O
F
F
T
H
E
S
A
M
E
M
A
Y
N
O
T
B
E
D
U
P
L
I
C
A
T
E
D
,
U
S
E
D
O
R
D
I
S
C
L
O
S
E
D
W
I
T
H
O
U
T
T
H
E
W
R
I
T
T
E
N
C
O
N
S
E
N
T
O
F
T
H
E
H
W
A
N
G
S
T
R
U
C
T
U
R
A
L
E
N
G
I
N
E
E
R
S
I
N
C
.
C
O
P
Y
R
I
G
H
T
A
L
L
R
I
G
H
T
S
R
E
S
E
R
V
E
D
.
DRAWN BY
LAST REVISED
DATE
PROJECT NO.
SHEET TITLE
DRAWING NO.
SHEET:OF:
-
Engineer Seal:
PA
R
I
S
B
A
G
U
E
T
T
E
Project :
03
-
-
17
L
A
S
T
U
N
A
S
D
R
.
AR
C
A
D
I
A
,
C
A
9
1
0
0
7
2023/03/02
R
E
R
LR
S
G
A
E
F
G
E
L
N
O
G
A
W
E HDOETS AHN
A
J
T
U
T
E
T
I
UC
L I F
R
O
S
T U
F
R
No. 5592
Exp.06-30-23
C A
IOSSENPRO
N
N
I
IA
E
R
N
3501 Ocean View Blvd.
Gl en da l e, CA 91208
j u n o @ h w a n g s e .c o m
T e l . 2 1 3 ) 2 6 8 -0 9 3 5
StructuralEngineers Inc.
Revisions
DESCRIPTIONNO.
SHEET NOTES
DESCRIPTION
PLAN LEGEND
SYMBOL
1.SEE SHEET S100 MATERIAL SPECIFICATIONS & ROOF FRAMING NOTES.
INDICATES (E)TRUSSES @24" O.C.
INDICATES KITCHEN HOOD. SEE DETAIL 1/S300
* EXISTING MEMBERS AND THEIR DIRECTIONS
SHALL BE VERIFIED WITH THE STRUCTURAL
PLAN BEFORE CONSTRUCTION.
INDICATES BLOCKING. SEE DETAIL 2/S300
2"
(N)
(E)EQUI.
(E
)
6
3
/
4
"
x
2
8
1
/
2
"
G
L
B
R
O
O
F
B
E
A
M
(E)6 3/4"x18" GLB ROOF BEAM
(E
)
T
R
U
S
S
E
S
@
2
4
"
O
.
C
.
DO
.
DO
.
(E
)
T
R
U
S
S
E
S
@
2
4
"
O
.
C
.
DO
.
(E)HDR.
DO
.
DO
.
DO
.
DO
.
(E
)
T
R
U
S
S
E
S
@
2
4
"
O
.
C
.
DO
.
(E)5 1/8"x28 1/2" GLB ROOF BEAM
(E
)
8
3
/
4
"
x
3
0
"
G
L
B
R
O
O
F
B
E
A
M
DO
.
(E
)
H
D
R
.
(E
)
H
D
R
.
(E
)
H
D
R
.
DO
.
DO
.
DO
.
DO
.
(E
)
T
R
U
S
S
E
S
@
2
4
"
O
.
C
.
DO
.
DO
.
DO
.
(E
)
T
R
U
S
S
E
S
@
2
4
"
O
.
C
.
DO
.
DO
.
DO
.
DO
.
(E
)
T
R
U
S
S
E
S
@
2
4
"
O
.
C
.
(N)
EQUI.
2
S300
TYP.
1
S300 TYP.
3
S300
TYP.
DO
.
DO
.
DO
.
DO
.
(E
)
T
R
U
S
S
E
S
@
2
4
"
O
.
C
.
DO
.
DO
.
DO
.
DO
.
(E
)
T
R
U
S
S
E
S
@
2
4
"
O
.
C
.
DO
.
DO
.
S300
03A
L
L
D
R
A
W
I
N
G
S
A
N
D
W
R
I
T
T
E
N
M
A
T
E
R
I
A
L
A
P
P
E
A
R
I
N
G
H
E
R
E
I
N
C
O
N
S
T
I
T
U
T
E
T
H
E
O
R
I
G
I
N
A
L
A
N
D
U
N
P
U
B
L
I
S
H
E
D
W
O
R
K
O
F
F
T
H
E
S
A
M
E
M
A
Y
N
O
T
B
E
D
U
P
L
I
C
A
T
E
D
,
U
S
E
D
O
R
D
I
S
C
L
O
S
E
D
W
I
T
H
O
U
T
T
H
E
W
R
I
T
T
E
N
C
O
N
S
E
N
T
O
F
T
H
E
H
W
A
N
G
S
T
R
U
C
T
U
R
A
L
E
N
G
I
N
E
E
R
S
I
N
C
.
C
O
P
Y
R
I
G
H
T
A
L
L
R
I
G
H
T
S
R
E
S
E
R
V
E
D
.
DRAWN BY
LAST REVISED
DATE
PROJECT NO.
SHEET TITLE
DRAWING NO.
SHEET:OF:
-
Engineer Seal:
PA
R
I
S
B
A
G
U
E
T
T
E
Project :
03
-
-
17
L
A
S
T
U
N
A
S
D
R
.
AR
C
A
D
I
A
,
C
A
9
1
0
0
7
02/03/2023
R
E
R
LR
S
G
A
E
F
G
E
L
N
O
G
A
WEHDOETSAHN
A
J
T
U
T
E
T
I
UC
L I F
R
O
S
T U
F
R
No. 5592
Exp.06-30-23
CA
IOSSENPRO
N
N
I
IA
E
R
N
3501 Ocean View Blvd.
Glendale, CA 91208
j u n o @ h w a n g s e .c o m
T e l . 2 1 3 ) 2 6 8 -0 9 3 5
StructuralEngineers In c .
Revisions
DESCRIPTIONNO.
DETAILS &
SECTION
1SCALE : N.T.S.
HOOD SECTION
10'-8"
SEE ARCH.
PLAN
5'-
2
"
SE
E
A
R
C
H
.
350S137-43
KITCHEN HOOD
UNISTRUTP1000
UNISTRUT
P1000
UNISTRUTP1000
UNISTRUT
P1000
KITCHEN HOOD
L4x4x1/4"
350S137-43@4 PLACESSEE PLAN
(E)WOOD BEAMSEE PLAN L4x4x1/4"
W/ 1/2"Ø M.B.(4)-10d COMMON NAIL
Wt=221 lbs
15'-8" MAX
2"
MI
N
.
6"
MA
X
.
2"
MI
N
.
L
1/2Ø ROD
BEYONDSEE PLAN
ROD STIFFENERHARDWARE
(L=24"O.C.
AT EACH ROD)TORQUE: SNUG TIGHT
2"
MI
N
.
6"
MA
X
.
2"
MI
N
.
L
UNISTRUT
P1000
1/2Ø RODBEYONDSEE PLAN
1/2Ø ROD
1/2Ø ROD
L L
L L
L L
UNISTRUTP1000
350S137-43
L4x4x1/4"
W/ 1/2"Ø M.B.
350S137-43
VIEW "A"
RIGID INSULATION(FIELD SUPPLIED)
14
"
DUCT(FIELD SUPPLIED)
HEAD OF BOLT TO BE ONINSIDE OF FLANGE(TYP. ALL CORNERS)
1/2"ØLAG SCREW
1"THK.POLYURETHANEFOAM16GA
3/8"Ø LAG SCREW
W/2"MIN. PENETRATION
@24"O.C.
2SCALE : N.T.S.
ROOF EQUIPMENT PAD DETAIL
(E)TRUSS JOISTSEE PLAN
(E)WALL
"A"
SEE PLAN
(E)WALL
SEE PLAN
2x10 LEDGER PER PLAN BY OTHERSATTACH TO TOP CHORD WITH10dx3" @6"O.C. AND (2)-10dx3" WEB.LEDGER MUST BE MINIMUM LENGTHREQUIRED TO REACH 2 TRUSS PANELPOINTS.
L4x4x1/4"
W/ 1/2"Ø M.B.
(E)TRUSS JOIST
2x10 LEDGER PER PLAN BY OTHERSATTACH TO TOP CHORD WITH10dx3" @6"O.C. AND (2)-10dx3" WEB.LEDGER MUST BE MINIMUM LENGTHREQUIRED TO REACH 2 TRUSS PANELPOINTS.
4x BLOCKING ANDHANGER BY OTHRES
ALT. DETAIL
5'-0"
12"12"
@3" O.C
3"
MI
N
.
350S137-43
350S137-43
4x6 BLOCKING
SIMPSON HANGER"BA" (TYP.)
(E)WOOD TRUSS
SEE PLAN
EQUIPMENT
SIMPSON A35
4x6 BLOCKING
4x8 #2@32"O.C.
15/32" PLYWOOD "CDX"W/8d @6/12
SIMPSON STRAPLSTA9 @16" O.C.
3/8"Ø LAG SCREWW/2"MIN. PENETRATION@24"O.C.4x8 #2
(5)-10d COMMON NAIL
@4-SIDE
SIMPSON HANGER"BA" (TYP.)
(TYP.)(E)WOOD TRUSS
SEE PLAN
(E)WOOD TRUSS
SEE PLAN
(TYP.)
(650LBS)
SIMPSON HANGER
"BA"
(E)PLYWOODSHEATHING
(E)TRUSS JOISTSEE PLAN
SIMPSON STRAP"H8" @16" O.C.
3SCALE : N.T.S.
ROOF EQUIPMENT PAD DETAIL
4x6 BLOCKING
SIMPSON HANGER"BA" (TYP.)
(E)WOOD TRUSSSEE PLAN
SIMPSON HANGER"BA" (TYP.)
(TYP.)
(E)WOOD TRUSSSEE PLAN (E)WOOD TRUSSSEE PLAN
4x6 BLOCKING(TYP.)
PRE-FAB. METAL CURBBY MANUFACTURER
MAU
MIN. (3)-1/4"Ø LAG SCREWW/3"MIN. PENETRATION
(E)WD. BEAM
SEE PLAN
@ EACH SIDE
I
N
T
E
R
I
O
R
D
E
S
I
G
N
M-1
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
LE
G
E
N
D
A
N
D
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
GE
N
E
R
A
L
N
O
T
E
S
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
49VL5GLG
CAKE STORAGE REFRIGERATOR 1
35600.0020BUNN1
CONVECTION OVEN 1
TUC-60TRUE1UNDERCOUNTER REFRIGERATOR 60" (TR)
CAKE PREP FRIDGE 48"2
UD-0310A1MANITOWICUNDERCOUNTER ICE MACHINE
COFFEE BREWER BUNN 53200.01011
TGM-22RV(B)-N6TURBO AIR
UNDERCOUNTER REFRIGERATOR 60"TURBO AIR JUR-60S-N6
GRINDER
DISPLAY CASE REFRIGERATED 60"1 TCGB-60UF-B-N
DECK OVEN (3 DECK)1 PARIS CROISSANT SD-3
4TV
2POS TOAST TOAST FLEX
1STAINLESS STEEL WORK TABLE 48"WT-EB3048
1STAINLESS STEEL WORK TABLE 36"
5' CUTTING BOARD W/L CLIP 1 CUTTING BOARD
1DROP IN HAND SINK
PREP. SINK 1 1B184-1D18R
3 COMPARTMENT SINK 1 E3S8-1620-14T18
HS-1317
TURBO AIR
NITRON COLD DRAFT SCHOLL COFFEE MACHINE1 BUNN WRDG-51600.0020
H: HOT WATER
C: COLD WATER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18A
19
20
20A
21
22
23
24
25A
26
27
28
29
30
31
33
34
35
35A
36
37
38
39
40
41
42
43
1 PARIS CROISSANTDECK OVEN STAND
BREAD RACK (TALL)1 PARIS CROISSANT
CONVECTION OVEN (2 DECK)1 MOFFAT TURBOFAN
1 MOFF-E35D6-26/2CCONVECTION OVEN STAND MOFFAT TURBOFAN
3 TDC-30-2RNEW DOUGH CONDITIONER TURBO AIR
GRAB AND GO BEVERAGE 1 TURBO AIR TOM-50-B-N
1 TCGB-48UF-B-NTURBO AIRDISPLAY CASE REFRIGERATED 48"
SANDWICH PREPARATION REFRIGERATOR 1 MST-72-NTURBO AIR
1
THERMAL DISPENSER BUNN 42700.02002
BLENDER, BAR BLENDTEC S885C2901-B1GB1D2
DONUT FRYER
CAKE MIXER KSM8990WH
MICROWAVE OVEN NE-1025F
BREAD SLICER
ESPRESSO MACHINE
1PITCHER RINSER BLENDTEC RAPID RINSER
EMPLOYEE LOCKER 2
HAND SINK JOHN BOOS PBHS-W-1410-P-SSLR2
44
16"x20"x12"CHEMICAL SHELVE & MOP RACK
27.9"X22"X23.6"
13.3"X14.6"X16.5"120V, 500W, 60HZ
20.25"X16.5"X12"NSF
NSF
60 3/8"x30 1/8"x29 3/4"UL, NSF
NSF, ETL8.6"X9"X17.3"120V/220V-, 3.8HP
208V-, 30APROVIDE WATER FILTER SYSTEMPROVIDE APPROVED BACKFLOW PREVENTER FLOOR SINKINDIRECT
59"X27 1/2"X28 3/4"ETL 2.5" CASTER
72 5/8"X30"X37"UL, NSF 5" CASTER 115V-, 5.7AMP, 2/5HP
120V-, 13.5AMP
2.5" CASTER 115V, 5.1A 1/5HP
13"X17 1/2"X6 3/8"NSF 1/2"1/2"DIRECT
84"X25.5"X45"NSF
1/2"1/2"DIRECT
6" LEG 1/2"1/2"
PROVIDE APPROVED BACKFLOW PREVENTER
ETL
48 1/2"X34 1/4"X50 1/8"NSF 115V- 7.5A, 1/3HP4" CASTER
28 3/4"X27 5/8"X79 7/8"115V, 2.2A 1/5HPETL4" CASTER
23.9"X26.8"X34.6"120V-, 7.3AMP
14"X10"X5"NSF 1/2"1/2"DIRECT
18"X18"X14"NSF 6" LEG PROVIDE APPROVED BACKFLOW PREVENTER
FOLLOWING C.D INDIRECT FLOOR SINK1/2"1/2"
DIRECTW/ 18" DRAIN BD.
FOLLOWING C.D.
NSF
1
1
3
1
KTCHNNAID
PANASONIC
TURBO CHEF ECO
SPE-203-161825
MOFF-E35D6-26/2
THE ECO
65"x42"x21"5" CASTER 220V, 3PH, (3) 40AMPINDIRECTFLOOR SINKUL, NSF PROVIDE APPROVED BACKFLOW PREVENTER
1
1
JAC
EVERSYS
PICOMATIC
E4
MOP SINK45
46B
46C
WALL MOUNT SHELF 36"1836NK3-METROSEAL
WALL MOUNT SHELF 36"1436NK3-METROSEAL
5
3
METRO SUPER ERECTA
METRO SUPER ERECTA
EAGLE F1916-12 & 312690
EL-5DR
KROWNE
JOHN BOOS
JOHN BOOS
1
54
55
STANDING SHELF (CHROME) 18" x 36"
STANDING SHELF (CHROME) 18" x 48"
70
71
STANDING SHELF (GREEN) 18" x 48"
STANDING SHELF (GREEN) 18" x 60"
2WALL MOUNT SHELF 24"METRO SUPER ERECTA 1824NK3-METROSEAL
86
86A
87
89
STAINLESS STEEL WALL-MOUNTED SHELF 6" x 36"
STAINLESS STEEL WALL-MOUNTED SHELF 6" x 60"
1
1
12X721
90
91
91A
91B
91C
WALL MOUNT SHELF 48" 1848NK3-METROSEAL
WALL MOUNT SHELF 72" 18X72
WALL MOUNT SHELF 72"
1
2
METRO SUPER ERECTA
1
2
14X72
12X72
STAINLESS STEEL WALL-MOUNTED SHELF 6" x 48"1
7
4
5
4
WALL MOUNT SHELF 72"
WALL MOUNT SHELF 72"
NSF 4" CASTER26"X20 1/4"X68 5/8"
50 7/8"X28"X78 1/2"NSF 4" CASTER 115V- 15.5A, 3/4HP
30"X28 1/2"X44 1/2"UL, NSF 6" LEG 115V- 10APROVIDE APPROVED BACKFLOW PREVENTER INDIRECT FLOOR SINK
WHOLE CAKE SHOWCASE, PB LED LIGHT
SHORT CAKE SHOWCASE, PB LED LIGHT
BACK LINE (FAN ON FRONT)
KITCHEN (FAN ON BACK)
PROVIDE WATER FILTER SYSTEM
5-TIER, 12"W x 20"D x 77"H
FOLLOWING C.D.
FOLLOWING C.D.
FOLLOWING C.D.
TUC-48-HC UL48 3/8"X30 1/8"X29 3/4"TRUE 115V-, 3AMP, 1/3HP5" CASTER
35 7/8"W x 77 1/2"H x 36 7/8"D
NSF, ETL35 7/8"W x 77 1/2"H x 36 7/8"D
220-240V, 60Hz, 12.5kW
208V, 60Hz, 11.2kWNSF, ETL
220-240V, 60Hz, 12.5kW208V, 60Hz, 11.2kW
31 1/2" x 48 3/4" x 77 7/8"ETL 115/60/1
601/2" X 34 1/4" X 50 1/8"NSF 115V- 7.5A, 1/3HP
20.2"W x 22.3"D x 35"H UL, NSF 120V/240V, 60 HERTZ
10"W x 28.4"D x 34"H NSF, ETL 120V, 60 HERTZ
120V, 60 HERTZ9.4"W x 18.6"D x 29.1"H
NSF, ETL
UL, ETL
NSF9.3"W x 13"D x 20.7"H
UL16.1"W x 23.5"D x 21.5"H 208/240 VAC, 60Hz, 20AMP
42.425"W x 3.531"D x 23.929"H
High Mode: 10” x 14” x 8.6Low Mode: 6.5” x 14” x 8.6”24 Volt
NSF8.8"W x20.5"D x 7.5" H
GSW USA
GSW USA 30"W x 48"L x 35" H
30"W x 36"L x 35" HGSW USA WT-EB3036
NSF
ETL
NSF
ETL
12"W x 20"D x 77" H
18"W x 36"L
14"W x 36"L
NSF
NSF
18"W x 24"L
18"W x 48"L
NSF
NSF
METRO 4'-0"X1'-6"X6'-0"1848 BR 5 TIES - 18" DEPTHNSF6" LEG
1836 BR 3'-0"X1'-6"X6'-0"5 TIES - 18" DEPTH6" LEGNSFMETRO
BLUEAIR 48"X12"WS1248 NSF
BLUEAIR 36"X12"WS1236 NSF
BLUEAIR 60"X12"WS1260 NSF
METRO SUPER ERECTA
METRO SUPER ERECTA
METRO SUPER ERECTA
METRO SUPER ERECTA
METRO SUPER ERECTA
BELSHAW 27"X40"X64"120V, 3PH, 0.5AMPETL6" LEG 44,000BTU718LCG
REGENCY 4'-0"X1'-6"X6'-0"NSF 5 TIES - 18" DEPTH6" LEG
REGENCY 5'-0"X1'-6"X6'-0"NSF 5 TIES - 18" DEPTH6" LEG
DUMP SINK JOHN BOOS1 20"X16"X12"PB-DISINK201612-X PROVIDE 2 FAUCETNSF-DIRECT
1DIPPER WELL KROWNE 16-149 NSF7 3/16 X 6 3/16 NSFNSF INDIRECT
(FLOOR MOUNTED)
PROVIDE APPROVED BACKFLOW PREVENTER
PROVIDE APPROVED BACKFLOW PREVENTER
PROVIDE APPROVED BACKFLOW PREVENTER
I
N
T
E
R
I
O
R
D
E
S
I
G
N
M-1.1
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
ME
C
H
A
N
I
C
A
L
S
C
H
E
D
U
L
E
S
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
AIR FLOW
CFMMARK PANEL
SIZEMODELMFRNECK
SIZE REMARKS
125-175
225-300
24"X24"
24"X24"
PMCTITUS
TITUS
8"X8"
10"X10"PMC
0-600 24"X24"50RTITUS -
NOTE:
2.
1.
1,2
1,2
1,2
PROVIDE O.B.D. AND PLASTER FRAME IN GYP. BOARD INSTALLATION &
MANUAL DAMPER IN T-BAR CEILING INSTALLATION.
SELECT DIFFUSERS TO MATCH CEILING COLOR.
1,214"X14"TITUS PMC375-600 24"X24"
-
S-1
-
S-2
-
S-3
-
R-1
1,2-TITUS S300FS0-300 12"X8"-
S-4
250-600 30"X24"350FLTITUS -1,2-
R-2
AIR BALANCE SCHEDULE
1 EF-1 1 DU85HFA CAPTIVEAIRE 1800 1.000 1373 ODP 0.750 0.4610 3 208 2.6 570 FPM 99 12.3
FAN
UNIT
NO
TAG QTY FAN UNIT MODEL #MANUFACTURER CFM ESP RPM MOTOR
ENCL HP BHP PHASE VOLT FLA DISCHARGE
VELOCITY
WEIGHT
(LBS)SONES
2 KMUA-1 1 A1-15D 15MF-1-MOD A1 -1800 0.400 1807 ODP,PREMIUM 1.000 0.9050 3 208 3.1 3.9A 15A 3.26 95.0°F 68.0°F 75.0°F 68.0°F 471 23
FAN
UNIT
NO
TAG QTY FAN UNIT MODEL #BLOWER HOUSING MIN
CFM
DESIGN
CFM ESP RPM MOTOR
ENCL HP BHP PHASE VOLT FLA MCA MOCP
EVAP
FLOW RATE
(Gal/Hr)
EVAP COOLER
ENTERING DB
TEMP
EVAP COOLER
ENTERING WB
TEMP
EVAP COOLER
LEAVING DB
TEMP
EVAP COOLER
LEAVING WB
TEMP
WEIGHT
(LBS)SONES
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
L3
01REFLECTED CEILING PLAN
1
AB
2
3
L5 L5
1
10'-0"
AFF
SERVICE COUNTER
L5 L5
L5
L5
L5
L5 L7 L7
L2 L2 L2
MIN. 18" 1HR RATED CEILING AROUND HOOD
W.I.C.
W.I.F.
L4 L4
L4 L4 L4 L4
BREAD
10'-0"
AFF
2
L2 L2
L2
L2
L2
L2
L2
8'-0"
AFF
1
REST ROOM
8'-0"
AFF
1
REST ROOM
10'-0"
AFF
2
SANDWICH
OFFICE
10'-0"
AFF
2
3
9'-0"
AFF
L1
L5
L5
L6 L6 L6
3
10'-0"
AFF
2
10'-0"
AFF
10'-0"
AFF
OPEN
L5 L5 L5
9'-0"
AFF
8'-0"
AFF
1
4
4
6
8'-0"
AFF
L5 L5
L5 L5
L5 L5
L5 L5
L5 L5
L5 L5
L5L5
L5
L5
L5
L5
3
EXP.
AFF
L3
L3
L3
L3
L3
L3
L3
L3
L3
L3
L3
L3 L3 L3 L3 L3 L3L3 L3
1
10'-6"
AFF
3
10'-0"
AFF
L1
L1
L1
L7 L7
L7 L7
L7
L7
L7 L7
L5
L5
L5
L5
L5
L7
L7
L7
L7
L7
L7
L8
L8 L8 L8
L9 L9
1 2
3
100 CFM
400 CFM
14"Ø
10"Ø
300 CFM
350 CFM
350 CFM
300 CFM
80 CFM
80 CFM
100 CFM
320 CFM
480 CFM
900 CFM
900 CFM 18"X14"
14"Ø EAD DUCT UP
TO KEF ON ROOF
1800 CFM
18X14 SAD DUCT FROM
MAU ON ROOF TO
CEILING SPACE
WITH 3M FIRE RATED
WRAP
KEF
1
300 CFM
200 CFM 460 CFM
320 CFM
60 CFM
10"Ø
10"Ø
6"Ø
12"Ø
16"Ø
10"Ø
6"Ø
6"Ø
8"Ø
10"Ø
12"Ø
18"Ø
10"Ø
14"Ø
14"Ø
10"Ø
10"Ø
10"Ø10"Ø
16"Ø
14"Ø 18"Ø
18"Ø
EXHAUST OUTLETS SERVING GREASE DUCT SYSTEMS SHALL
TERMINATE ABOVE THE ROOF SURFACE, 10 FEET FROM PROPERTY
LINE, 10 FEET FROM AIR INTAKE OPENINGS AND 10 FEET ABOVE
ADJOINING GRADE. BASE OF FAN SHALL BE 40 INCHES ABOVE
ROOF SURFACE. LAMC 510.9.1
NON-GREASE DUCTS SHALL BE CONSTRUCTED IN ACCORDANCE
WITH SMACNA-2006 OR UL 181 LAMC 602.1
6"Ø UP THROUGH ROOF
WITH BACKDRAFT DAMPER
TERMINATEWITH GOOSE NECK
FACING DOWN 12"ABOVE
ROOF
NOTE:
DUCT TRUNKS FROM RTU
ON ROOF TO CEILING
SPACE
CONNECT TO EXISTING
DUCT TRUNKS FROM RTU
ON ROOF TO CEILING
SPACE
MVD (TYP)
MVD (TYP)
MVD (TYP)
12"Ø
16"Ø8"Ø
16"Ø
8 FEET LINEAR DIFFUSER
RTU
2
OPERATING WEIGHT
600#
(NEW)(E)
OPERATING WEIGHT
176#
1800CFM
1800CFM
ENVIROMENTAL EXHAUST OUTLETS SHALL TERMINATE NO LESS
THAN 3 FEET FROM PROPERTY LINE, 3 FEET FROM OPENINGS
INTO BUILDING AND 10 FEET FROM ANY FORCE INTAKE.
OUTSIDE AIR FOR HEATING OR COOLING SYSTEM SHALL NOT BE
TAKEN FROM LESS THAN 10 FEET IN DISTANCE FROM
APPLIANCE VENT OUTLET, A VENT OF A PLUMBING DRAINAGE
SYSTEM, THE DISCHARGE OUTLET OF AN EXHAUST FAN, OR
MEDICAL-SURGICAL VACUUM OUTLET UNLESS THE OUTLET IS 3
FEET ABOVE THE OUTSIDE AIR INLET.
THE AIR FILTERS FOR OUTSIDE ANS RETURN AIR HAVE A
MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 13. CMC
401.2, TITLE 24 SEC.120.0 (B) 1C; 1200(C) 1 B; 150.0(M) 12 C
NOTE:
6"Ø UP THROUGH ROOF WITH
BACKDRAFT DAMPER TERMINATE
WITH GOOSE NECK FACING DOWN 12"
ABOVE ROOF
I
N
T
E
R
I
O
R
D
E
S
I
G
N
M-2
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
KI
T
C
H
E
N
E
Q
U
I
P
M
E
N
T
P
L
A
N
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
MECHANICAL FLOOR PLANMECHANICAL ROOF PLAN
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
NOT TO SCALE
WELD OR BRAZE ALL DUCT JOINTS AND SEAMS ON THE EXTERNAL SURFACE.
DO NOT PENETRATE DUCT WALLS WITH SCREWS, NAILS, ETC.
SECTIONS OF DUCT SHALL NOT CONTAIN GREASE POCKETS.
GREASE DUCTS SHALL COMPLY WITH 2013 CMC CHAPTER 5 REQUIREMENTS.
NOTES:
(TYPICAL)
6" MIN.
ROOF
AT POINT OF PENETRATION
P.O.C
48" MAX.
CEILING
METAL SHIELD OR COLLAR
LOW VOLTAGE CONTROL WIRES AND CONDUITS BY MECHANICAL CONTRACTOR.
3M DUCT WARP 615+
WHEN SLOPE DUCT OCCURS TO HOOD
MINIMUM 1/4" PER LINEAR FOOT IF RUN
IS LESS THAN 75 FT. SLOPE 1" PER
LINEAR FOOT IF RUN IS MORE THAN 75
FT.
MIN. 22 GAGE STAINLESS STEEL KITCHEN
EXHAUST HOOD
MIN. 22 GAGE STAINLESS STEEL SOLID
FLASHING FOR HOODS LESS THAN 12"
FROM CEILING OR WALL (TYPICAL)
18 GAGE STAINLESS STEEL KITCHEN EXHAUST
DUCT WELD ALL DUCT JOINTS & SEAMS ON
THE EXTERNAL SURFACE. DO NOT
PENETRATE DUCT WALLS WITH SCREWS,
NAILS ETC.
CLEANOUT DOORS IN DUCTS
SHALL BE SLIDING OR HINGED
PROVIDE ACCESS TO ALL DUCT CLEANOUTS
PROVIDE ADEQUATE CLEANOUT OPENINGS FOR THOROUGH DUCT SYSTEM
CLEANING. MINIMUM ONE EVERY 12 FT. OF STRAIGHT DUCT & ONE AT EACH
CHANGE OF DIRECTION.
MINIMUM VELOCITY
1500 FPM & MAX. 2000
FPM.
NOT TO SCALE
TRAILING
3/4" FLAT
1-1/2" TYP.
EDGE (TYP.)
CHANNEL
1-1/2" TYP.
RUNNER
CRIMP (TYP.)
FLO
W
R=2"
VANES AND FRAMES - 24 GAUGE.
WELDED TO ELBOW.
FRAMES AND CHANNELS - BOLTED OR TACK
MAXIMUM UNSUPPORTED VANE LENGTH 36".
TURNING VANES
FLOW
VANED ELBOW
NOTES:
FRAME
NOT TO SCALE
NOT TO SCALE
BIRD SCREEN
SCREW (TYP. 8 PLACES)
W/ 1/4"Øx3/4" LONG LAG
THK.<ANCHOR TO STRUCT1 1/2"x1 1/2"x1/4"
TRANSITION FITTING
4" MIN.
SEE PLAN FOR SIZE
EXHAUST DUCT
(TYP. FOR 4)SLACK CABLE
1/8"Ø SEISMIC
CEILING SPACE
ROOF
SUPPORT EXHAUST FAN
(4) #12 GA. WIRES TO
EXHAUST FAN
ROOF JACK DISCHARGE
LAG TO 4" HIGH ROOF
CURB (4" HIGH MIN.)
NOTE:
SECURE DIFFUSER
WITH SUPPORT
WIRE (TYPICAL)
ACOUSTICAL FLEX. DUCT
VOLUME DAMPER
CEILING
SPIRAL DUCT
4" WIDE SHEET
METAL STRAP
CLAMPING DEVICE (TYP.)
RETURN AIR REGISTER
INSTALLATION SIMILAR
5'-0" MAXIMUM LENGTH
1. CUT THE FIRST LAYER OF DUCT WRAP TO A LENGTH SUFFICIENT TO WRAP COMPLETELY AROUND THE PERIMETER OF THE DUCT, PLUS PROVIDE
AN OVERLAP OF NOT LESS THAN 3 INCHES. USE ALUMINUM FOIL TAPES TO SEAL CUT EDGES OF THE BLANKET. ROLL OUT DUCT WRAP
MATERIAL TAUTLY BEFORE MEASURING TO MINIMIZE WASTE. HOLD THE FIRST LAYER WRAP OF DUCT WRAP IN PLACE USING FILAMENT TAPE.
SPACE THE TAPE 1?INCHES FROM THE EDGES OF EACH BLANKET AND MIDWAY BETWEEN 10?INCHES ON CENTER. CUT THE NEXT ADJACENT
INTERIOR WRAP TO COMPLETELY WRAP AROUND THE PERIMETER OF THE DUCT WITH ENOUGH EXCESS TO PROVIDE AN OVERLAP OF NOT LESS
THAN 3 INCHES. A 3-INCH LONGITUDINAL OVERLAP ONTO THE PREVIOUS ADJACENT WRAP IS REQUIRED ON BOTH LAYERS.
2. CUT THE SECOND LAYER OR TO SUFFICIENT LENGTH TO WRAP COMPLETELY AROUND THE PERIMETER OF THE INTERIOR WRAP WITH SUFFICIENT
EXCESS TO PROVIDE AN OVERLAP OF NOT LESS THAN 3 INCHES. INSTALL DUCT WRAP AS THE EXTERIOR LAYER SHALL BE CUT, IF NEEDED,
AND PROPERLY LOCATED TO ENSURE THAT THE LONGITUDINAL OVERLAP JOINTS OF THE EXTERIOR LAYER OF BLANKET ARE STAGGERED 10?
INCHES FROM THOSE OF THE INTERIOR LAYER. USE ALUMINUM FOIL TAPE TO SEAL ANY CUT EDGES OF THE BLANKET. POSITION THE EXTERIOR
LAYER SUCH THAT THE PERIMETER OVERLAP JOINTS ARE SPACED AT LEAST 12 INCHES FROM THOSE OF THE INTERIOR LAYER.
3. USE FILAMENT TAPE AS A TEMPORARY HOLD PRIOR TO BANDING TO EASE INSTALLATION.
4. HOLD THE EXTERIOR DUCT WRAP IN PLACE USING BANDING MATERIAL. PLACE THE BANDS 1?INCHES FROM EACH BLANKET EDGE AND MIDWAY
BETWEEN 10?INCHES ON CENTERS. THE TENSION OF THE BANDING MATERIAL SHALL BE SUFFICIENT TO HOLD DUCT WRAP SNUGLY IN PLACE,
BUT NOT CAUSE ANY CUTTING OR DAMAGE TO THE BLANKET.
5. NOTE THAT SUPPORT HANGER SYSTEMS DO NOT NEED TO BE WRAPPED PROVIDED THE HANGER RODS ARE AT LEAST A MINIMUM OF 3/8-IN.
DIAMETER AND THE ANGLE IRON IS A MINIMUM OF 1?IN. X 1?IN. X 1/8-IN.
TWO LAYERS OF DUCT WRAP
FILAMENT TAPE OF 34-IN WITH MINIMUM
BANDING OF BARBON STEEL OF 34-IN. WIDTH AND 0.015-IN. THICKNESS,
AND BANDING CLIPS
PERIMETER OVERLAP OF 3 INCHES
LONGITUDINAL OVERLAP OF 3 INCHES
HANGER ROD OF 3/8-INCH SIZE MINIMUM
DUCT SUPPORT ANGLE, 112" x 112" x 18" MIN.
DOOR OPENING AT GREASE DUCT
STEEL ANGLE OPENING FRAME - WELD TO DUCT.
ALL THREADED ROD OF ?INCH DIA. SIZE, 4?TO 5 INCHES LONG - WELD TO THE CORNERS OF THE PERIMETER
REINFORCEMENT FRAME OF THE DOOR OPENING. (4 PLACES)
ACCESS COVER OF 16 GAGE STEEL
INSULATION PINS OF COPPER-COATED STEEL, 10 GAGE, 4 TO 5 INCHES LONG - WELD TO THE DOOR PANEL FOR BLANKET
INSTALLATION. TURN DOWN PINS THAT EXTEND BEYOND THE OUTER DUCT WRAP TO AVOID SHARP EDGES ON THE
DOOR.
FIRST LAYER DUCT WRAP - CUT AS 1-INCH STEP JOINT CONSTRUCTION AND IMPALE OVER THE INSULATION PINS ON THE
DOOR PANEL TO ALLOW FOR A TIGHT FIT AND NO THROUGH OPENINGS.
SECOND LAYER DUCT WRAP - CUT AS 1-INCH STEP JOINT CONSTRUCTION AND IMPALE OVER THE INSULATION PINS ON
THE DOOR PANEL TO ALLOW FOR A TIGHT FIT AND NO THROUGH OPENINGS.
THIRD LAYER DUCT WRAP - CUT AS 1-INCH STEP JOINT CONSTRUCTION AND IMPALE ON TOP OF THE TWO PREVIOUS
DOOR PANEL LAYERS AND OVERLAP OF NOT LESS THAN 1 INCH AROUND THE PERIMETER OF THE DOOR OPENING.
SPEED CLIPS OF MINIMUM 1?IN. x 1?-IN. SQUARE OR 1?INCH DIAMETER SIZE TO LOCK THE BLANKET LAYERS IN PLACE.
ALUMINUM TAPES COVERING ALL EXPOSED EDGES
HOLLOW STEEL TUBING OF 4-INCH LENGTH FOR THREADED RODS TO ACT AS PROTECTION SLEEVES FOR DUCT WRAP
WHEN FASTENING THE DOOR.
WING NUT OF ?INCH DIA. SIZE
1. CUT TWO LAYERS OF DUCT WRAP AS 1-INCH STEP JOINT CONSTRUCTION AND IMPALE OVER THE INSULATION PINS ON THE DOOR PANEL TO
ALLOW FOR A TIGHT FIT AND NO THROUGH OPENINGS.
2. CUT A THIRD LAYER OF 3M FIREMASTER DUCT WRAP IN A LIKE MANNER, IMPALE ON TOP OF THE TWO PREVIOUS DOOR PANEL LAYERS AND
OVERLAP OF NOT LESS THAN 1 INCH AROUND THE PERIMETER OF THE DOOR OPENING. THEN, LOCK THE BLANKET LAYERS IN PLACE WITH
MINIMUM 1?IN. X 1?-IN. SQUARE OR 1?INCH DIAMETER ROUND SPEED CLIPS. TURN DOWN INSULATION PINS THAT EXTEND BEYOND THE
OUTER DUCT WRAP TO AVOID SHARP EDGES ON THE DOOR.
3. APPLY ACCESS DOOR LABELS TO ALL ACCESS CLEAN OUT DOORS.
NOTES
18" MIN.
DEEP FRYER
(E) 1 HR. FIRE RATED
WALL
3"
3M DUCT WARP 615+
3M DUCT WARP 615+
GREASE DUCT TO
EXTEND 18" MIN
ABOVE ROOF
NOT TO SCALE
(N) QUARRY TILE
FINISH OVER CONC.
FLOOR
18" CLEARANCE TO
NON-COMBUSTIBLE 22
GAGE STAINLESS STEEL
SOLID AND SEALED
AROUND HOOD
OR FIREMASTER FASTWRAP XL
OR FIREMASTER FASTWRAP XL
I
N
T
E
R
I
O
R
D
E
S
I
G
N
M-3
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
DE
T
A
I
L
S
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
1 H-1 6024
ND-2 CAPTIVEAIRE 11' 0"450
DEG I MEDIUM 164 1800 4"14"1800 1684 -0.834"430 SS
WHERE EXPOSED ALONE ALONE
HOOD
NO TAG MODEL MANUFACTURER LENGTH
MAX
COOKING
TEMP
TYPE APPLIANCE
DUTY
DESIGN
CFM/FT
TOTAL
EXH CFM
EXHAUST PLENUM
RISER(S)
WIDTH LENG HEIGHT DIA CFM VEL SP
HOOD
CONSTRUCTION
HOOD CONFIG
END TO
END ROW
1 H-1 CAPTRATE SOLO FILTER 8 16"16"85% SEE FILTER SPEC 3 RECESSED ROUND NO RIGHT 12"x60"x24"TANK FS 4.0/4.0 DCV-1111
1 LIGHT
1 FAN
YES 832
LBS
HOOD
NO TAG
FILTER(S)
TYPE QTY HEIGHT LENGTH EFFICIENCY @ 7 MICRONS
LIGHT(S)
QTY TYPE WIRE
GUARD
UTILITY CABINET(S)
LOCATION SIZE
FIRE SYSTEM
TYPE SIZE
ELECTRICAL
MODEL #
SWITCHES
QUANTITY
FIRE
SYSTEM
PIPING
HOOD
HANGING
WEIGHT
1 H-1
LEFT END STANDOFF (FINISHED) 1" WIDE 60" LONG INSULATED.
RIGHT VERTICAL END PANEL 27" TOP WIDTH, 21" BOTTOM WIDTH, 80" HIGH INSULATED 430
SS.
LEFT WALL AS END PANEL.
HOOD
NO TAG OPTION
1 FS-1 TANK FS 4.0/4.0 37 FIRE CABINET RIGHT RIGHT, HOOD 1
FIRE
SYSTEM
NO
TAG TYPE SIZE FLOW
POINTS
INSTALLATION
SYSTEM LOCATION ON HOOD
1 FS-1 SC ELECTRICAL 2.000 CAPTIVEAIRE SYSTEMS
FIRE
SYSTEM
NO
TAG TYPE SIZE SUPPLIED BY
1 EF-1 1 DU85HFA CAPTIVEAIRE 1800 1.000 1373 ODP 0.750 0.4610 3 208 2.6 570 FPM 99 12.3
FAN
UNIT
NO
TAG QTY FAN UNIT MODEL #MANUFACTURER CFM ESP RPM MOTOR
ENCL HP BHP PHASE VOLT FLA DISCHARGE
VELOCITY
WEIGHT
(LBS)SONES
FOR QUESTIONS CALL:
PHONE: 310.876.8505
REFERENCE JOB NUMBER
ANDREW WYSOPALLOS ANGELES SALES OFFICE
REG81@CAPTIVEAIRE.COM
Operation of All CaptiveAire Equipment to be
Verified by Factory Service Technician. Equipment
Must be Operational and Fire System shall be Hooked-up
and Armed. Report to be Sent to Customer by
Manufacturer When Complete.
,
.
NOTE- Exhaust Collar Must be Factory Installed. If A Different Size Or Location is
Required, Please Note Change On Submittal.
Rear Discharge Is Available. Contact CaptiveAire For Possible Locations.
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
BU
I
L
T
NFP
A
WIT
H
IN
R
5700997
MASTER DRAWING
asw-81
Pa
r
i
s
B
a
g
u
e
t
t
e
-
A
r
c
a
d
i
a
,
C
A
17
L
a
s
T
u
n
a
s
D
r
i
v
e
,
Lo
s
A
n
g
e
l
e
s
O
f
f
i
c
e
18
1
0
1
4
t
h
S
t
S
u
i
t
e
2
1
4
,
S
a
n
t
a
M
o
n
i
c
a
,
C
A
,
9
0
4
0
4
P
H
O
N
E
:
(
3
1
0
)
8
7
6
-
8
5
0
5
F
A
X
:
(
9
1
9
)
7
4
7
-
5
6
3
9
E
M
A
I
L
:
r
e
g
8
1
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
Ar
c
a
d
i
a
,
C
A
,
9
1
0
0
7
2 RTU-1 1 CASRTU1-18-6T-DOAS CAPTIVEAIRE 18MF-1-RTU 0 1800 1800 1288 1.500 2.00 3 208 33.2A 35A 95.0°F 68.0°F 52.4°F 52.4°F 52.5°F 80.1 MBH 78.4 MBH 19.5 9.2 70.0°F 61.7°F 35.1 MBH 56 MBH 1.5 LBS/HR 50.0°F 31.0°F 81.0°F 5.7 1,2,3,4,5,6,7,8,9,10,11,12,13
NOTES:
1. INVERTER SCROLL COMPRESSOR WITH INTEGRATED OIL SENSOR. DIGITAL OR STAGED SCROLL NOT AN APPROVED EQUAL
2. DIRECT DRIVE PLENUM BLOWER. BELT DRIVEN BLOWERS ARE NOT ACCEPTABLE
3. INTEGRATED MONITORING VIA CELLULAR CONNECTION BY MANUFACTURER
4. REFRIGERATION PRESSURE MONITORING ON HIGH AND LOW PRESSURE SIDE OF SYSTEM INCLUDED THROUGH DIGITAL INTERFACE
5. EC MOTOR CONDENSING FANS
6. ELECTRONIC EXPANSION VALVE. TXV NOT ACCEPTABLE
7. SUCTION LINE ACCUMULATOR
8. FACTORY COMMISSIONING WITH 5 YEAR PARTS WARRANTY
9. AVERAGING INTAKE, EVAP AND DISCHARGE TEMPERATURE SENSORS (DISCHARGE SENSOR TO BE FACTORY MOUNTED WITHIN UNIT)
10. SUPPLY CFM MONITORING INTEGRAL TO UNIT WITH CFM MEASUREMENT INCLUDED THROUGH DIGITAL INTERFACE
11. FULLY MODULATING HOT GAS REHEAT
12. 1" EXTERIOR DUAL-WALL CONSTRUCTION W/ R-4.3 INSULATION– MINIMUM 24GA EXTERIOR W/ 18GA BASE
13. DOWN DISCHARGE/NO RETURN
FAN INFORMATION
FAN
UNIT
NO
TAG QTY DOAS/RTU MODEL #MANUFACTURER BLOWER RETURN
AIR CFM
MAX
OUTSIDE
AIR CFM
TOTAL
CFM
WEIGHT
(LBS)ESP
ELECTRICAL INFORMATION
HP PHASE VOLT MCA MOCP
COOLING INFORMATION
OUTSIDE AIR
DB WB
LEAVING AIR
DB WB DP
CAPACITY
TOTAL SENS.IEER ISMRE
REHEAT INFORMATION
DISCHARGE
DB WB
CAPACITY
DESIRED MAX
MOISTURE
REMOVAL
RATE
HEAT PUMP INFORMATION
ENTERING
TEMP
MAX
TEMP RISE
DISCHARGE
TEMP COP NOTES
1
2
EF-1
RTU-1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
GREASE BOX
FAN BASE CERAMIC SEAL - INSTALLED AT PLANT - FOR GREASE DUCTS
2 YEAR PARTS WARRANTY
RTU TOTAL CFM MONITORING
SINGLE POINT ELECTRICAL CONNECTION FOR RTU. 750VA TRANSFORMER USED. IF A NON-DCV
PREWIRE CONTROLS THIS UNIT, THE #28, #47, "MA", OR "E2" PREWIRE OPTION MUST
BE SELECTED. DOES NOT PROVIDE SUPPLY STARTER IN PREWIRE
CASLINK BUILDING MONITORING SYSTEM - INTERNET OR CELLULAR CONNECTION REQUIRED
2" MERV 13 FILTERS FOR RTU1 (QTY. 4)
2" MERV 8 FILTERS FOR RTU1 (QTY. 4)
OVERHEAT STAT
VFD FACTORY MOUNTED AND WIRED IN RTU COMMERCIAL CONTROL VESTIBULE
RTU1 DOWN DISCHARGE
RTU FIXED 100% OA INTAKE CONTROL
RTU1 NO RETURN - 100% OA
REMOTE TEMPERATURE AND HUMIDITY SPACE SENSOR
6 TON MODULATING COOLING OPTION WITH HEAT PUMP, 208/230V. R410A REFRIGERANT,
VARIABLE SPEED COMPRESSOR, ECM CONDENSING FANS
6 TON MODULATING REHEAT OPTION WITH HEAT PUMP - SPACE DEWPOINT CONTROL
RTU1 CURB DUCT HANGER
OCCUPIED SCHEDULING
COMMERCIAL SMOKE DETECTOR/ALARM INTERLOCK - ALARM SUPPLIED BY OTHERS
CLOGGED FILTER SWITCH - NOTIFICATION ON HMI
RTU1 CONVENIENCE OUTLET (GFCI), 15 AMP - REQUIRES SEPARATE 120V CONNECTION.
INCLUDES RECEPTACLE, COVER AND J BOX
VAV PACKAGE W/ 0-10VDC INPUT CONTROL (571 VFD INCLUDED)
5 YEAR ENTIRE UNIT PARTS WARRANTY, 10 YEAR ENTIRE UNIT PARTS WARRANTY WITH REMOTE
MONITORING AND CAPTIVEAIRE SERVICE CONTRACT
FAN
UNIT
NO
TAG QTY DESCRIPTION
1
2
# 1
# 2
EF-1
RTU-1
36 LBS
59 LBS
CURB
CURB
23.000"W X 23.000"L X 20.000"H ALONG LENGTH, RIGHT VENTED HINGED.
41.000"W X 71.000"L X 14.000"H ALONG WIDTH, RIGHT INSULATED.
NO ON
FAN TAG WEIGHT ITEM SIZE
I
N
T
E
R
I
O
R
D
E
S
I
G
N
M-4
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
HO
O
D
I
N
F
O
R
M
A
T
I
O
N
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
1500500
FLOW RATE (CFM)
1000
0.00
0
0.50
PR
E
S
S
U
R
E
D
R
O
P
(
i
n
.
H
2
0
)
PRESSURE DROP VS. FLOW RATE
RRSPECIFICATION: CAPTRATE GREASE-STOP SOLO FILTER
A UNIQUE S-BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN,
THE CAPTRATE GREASE-STOP SOLO FILTER IS A SINGLE-STAGE FILTER FEATURING
LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE.
FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD
GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE
PARTICLES FIVE MICRONS IN SIZE, AND 85% GREASE PARTICLES SEVEN MICRONS IN SIZE AND
COMPONENTS WHEN ASSEMBLED.
2-INCH DEEP HOOD CHANNEL(S).
TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY.
UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO
FR
A
C
T
I
O
N
A
L
E
F
F
I
C
I
E
N
C
Y
(
%
)
0
0.1
20
40
1.0
PARTICLE DIAMETER (UM)
10.0
EFFICIENCY VS. PARTICLE DIAMETER
60
80
100
THE CAPTRATE GREASE-STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05.
TE
A
NSF ACCORDANCE
No. 96
NFPA
WITH
BUILT
IN
SLI DTE
RO
CH
B
N
RAN I,OR M
.
YR
OR
LAIGNTSB
AT
CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH:.
NFPA #96.
NSF STANDARD #2.
UL STANDARD #1046.
INT. MECH. CODE (IMC).
ULC-S649.
1.00
1.50
2.00
2.50
3.00
3.50
MANUFACTURER APPROVED FOR USE IN SOLID FUEL APPLICATIONS AS A SPARK ARRESTER.
11' 0"NOM./11' 0.00"OD.
12'-1.00" OVERALL LENGTH
60"
12"
UTILITY
CABINET.
1" LAYER OF INSULATION
FACTORY INSTALLED IN
1.00" END STANDOFF MEETS
0" REQUIREMENTS CLEARANCE
TO COMBUSTIBLE SURFACES.
1"
3"
§
66"66"
10 1/2"
Ø14"
U.L. LISTED RECESSED ROUND LED
FIXTURE AND LED LIGHT.
INSTALLER MUST CONFIRM HOOD IS INSTALLED SUCH
THAT THE SPECIFIED WALL, ACTING AS AN END PANEL,
IS MATED TIGHT TO THE CORRECT END OF HOOD TO
ACHIEVE A REDUCED MINIMUM EXHAUST CFM LISTING.
NON-COMPLIANCE WILL NULLIFY THE ETL LISTING,
VOID THE MANUFACTURER'S WARRANTY, AND HOLD THE
CONTRACTOR LIABLE FOR ANY AND ALL LOSSES, COSTS,
AND EXPENSES RELATED TO THE NON-CONFORMANCE OF
THE MANUFACTURER'S SPECIFIED INSTRUCTION. THE
WALL ACTING AS AN END PANEL MUST EXTEND NO LESS
THAN 20" FROM THE INTERSECTING WALL ON WHICH HOOD
IS MOUNTED AND MUST EXTEND NO LESS THAN 20" UNDER
BOTTOM OF HOOD TO BE ELIGIBLE FOR REDUCED
MINIMUM EXHAUST CFM LISTING.
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUT.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUTS.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL ALL-THREAD.
HOOD CORNER
HANGING ANGLE
(WEIGHT BEARING
ANCHOR POINT
FOR HOOD).
HOOD CORNER
HANGING ANGLE
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUTS.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
ASSEMBLY INSTRUCTIONS
HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5
(MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING
ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS
AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE
DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING
ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF EXPOSED
THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57
FT-LBS.
(HARDWARE BY INSTALLER)
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUT.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
FULL LENGTH
HANGING ANGLE
(WEIGHT BEARING
ANCHOR POINT
FOR HOOD).
FULL LENGTH
HANGING ANGLE
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL ALL-THREAD.
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUTS.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUT.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
ASSEMBLY INSTRUCTIONS
HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5
(MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING
ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS
AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE
DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS.
SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR
FULL LENGTH HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED
THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57
FT-LBS.
(HARDWARE BY INSTALLER)
3" INTERNAL STANDOFF.
GREASE DRAIN
WITH REMOVABLE CUP.
SEE HOOD TABLE.
§EXHAUST RISER.
HANGING ANGLE.
RECESSED ROUND LED FIXTURE AND LED LIGHT,
3500 K WARM OUTPUT.
20"
4"
4 1/2"
21"
27"
80"
RIGHT VERTICAL END PANEL
WITH ADJUSTABLE LEGS.
GAS CHASE CUTOUT
(FOR GAS AND POWER LINES).
LEFT WALL AS END PANEL.
EQUIPMENT
BY OTHERS.
48.0" MAX.
80"
24" NOM.
60"
IT IS THE RESPONSIBILITY
OF THE ARCHITECT/OWNER TO
ENSURE THAT THE HOOD CLEARANCE
FROM LIMITED-COMBUSTIBLE
AND COMBUSTIBLE MATERIALS
IS IN COMPLIANCE WITH
LOCAL CODE REQUIREMENTS.
16" CAPTRATE SOLO
FILTER WITH HOOK.
4.166"Shelf With
2.25"Condensate
MUA
2.25"
2.25"2.25"
4.166"
IN THE FOLLOWING LOCATIONS
FOR WALL CANOPIES
HANGING ANGLES WILL BE LOCATED
REAR
FROM
DIM
Only
Back OnlyExhaust
MUA
With
Wall Exhaust
HOOD STYLE
DIM DIM
2.25"2.25"
2.25"2.25"
Hood)Hood)
2.25"2.25"
(24" High
FRONT
FROM
(30" High
FRONT
FROM
GREASE CUP WILL BE SUPPORTED BY TWO STUDS ON
THE INSIDE WALL OF THE HOOD. THE GREASE WILL DRAIN
THROUGH A CONCEALED GREASE TROUGH AND INTO
THIS REMOVEABLE/CLEANABLE CUP.
MC
Intertek
I
T
A
N
S
TED
ION L SIAT
RE
S
I
S
T
A
N
C
E
(
i
n
.
H
2
0
)
CAPTRATE R
AIRFLOW (cfm)
0.2
0.4
400
0
0 200 600 800 1000
0.6
0.8
1.2
1
1.4
RESISTANCE VS. AIRFLOW
1.6
2" Captrate Grease-Stop Solo FilterRR
Captrate
Grease-Stop Solo Filter
1/2" - 13 TPI
GRADE 5 (MINIMUM)STEEL HEX NUT
1/2" GRADE 5(MINIMUM) STEEL
FLAT WASHER
1/2" - 13 TPIGRADE 5 (MINIMUM)
STEEL HEX NUTS
1/2" GRADE 5(MINIMUM) STEELFLAT WASHER
1/2" - 13 TPI
GRADE 5 (MINIMUM)STEEL ALL-THREAD
HOOD CORNERHANGING ANGLE(WEIGHT BEARING
ANCHOR POINTFOR HOOD)
HOOD CORNER
HANGING ANGLE
1/2" - 13 TPI
GRADE 5 (MINIMUM)STEEL HEX NUTS
1/2" GRADE 5
(MINIMUM) STEELFLAT WASHER
(HARDWARE BY INSTALLER)
NOTE:
SEE INSTALLATION
MANUAL FOR
MORE INFORMATION
4.166"Shelf With
2.25"Condensate
MUA
2.25"
2.25"2.25"
4.166"
IN THE FOLLOWING LOCATIONS
FOR WALL CANOPIES
HANGING ANGLES WILL BE LOCATED
REAR
FROM
DIM
Only
Back OnlyExhaust
MUA
With
Wall Exhaust
HOOD STYLE
DIM DIM
2.25"2.25"
2.25"2.25"
Hood)Hood)
2.25"2.25"
(24" High
FRONT
FROM
(30" High
FRONT
FROM
GREASE CUP WILL BE SUPPORTED BY TWO STUDS ON
THE INSIDE WALL OF THE HOOD. THE GREASE WILL DRAIN
THROUGH A CONCEALED GREASE TROUGH AND INTO
THIS REMOVEABLE/CLEANABLE CUP.
MC
Intertek
I
T
A
N
S
TED
ION L SIAT
RE
S
I
S
T
A
N
C
E
(
i
n
.
H
2
0
)
CAPTRATE R
AIRFLOW (cfm)
0.2
0.4
400
0
0 200 600 800 1000
0.6
0.8
1.2
1
1.4
RESISTANCE VS. AIRFLOW
1.6
2" Captrate Grease-Stop Solo FilterRR
Captrate
Grease-Stop Solo Filter
1/2" - 13 TPI
GRADE 5 (MINIMUM)STEEL HEX NUT
1/2" GRADE 5(MINIMUM) STEEL
FLAT WASHER
1/2" - 13 TPIGRADE 5 (MINIMUM)
STEEL HEX NUTS
1/2" GRADE 5(MINIMUM) STEELFLAT WASHER
1/2" - 13 TPI
GRADE 5 (MINIMUM)STEEL ALL-THREAD
HOOD CORNERHANGING ANGLE(WEIGHT BEARING
ANCHOR POINTFOR HOOD)
HOOD CORNER
HANGING ANGLE
1/2" - 13 TPI
GRADE 5 (MINIMUM)STEEL HEX NUTS
1/2" GRADE 5
(MINIMUM) STEELFLAT WASHER
(HARDWARE BY INSTALLER)
NOTE:
SEE INSTALLATION
MANUAL FOR
MORE INFORMATION
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
BU
I
L
T
NFP
A
WIT
H
IN
R
5700997
MASTER DRAWING
asw-81
Pa
r
i
s
B
a
g
u
e
t
t
e
-
A
r
c
a
d
i
a
,
C
A
17
L
a
s
T
u
n
a
s
D
r
i
v
e
,
Lo
s
A
n
g
e
l
e
s
O
f
f
i
c
e
18
1
0
1
4
t
h
S
t
S
u
i
t
e
2
1
4
,
S
a
n
t
a
M
o
n
i
c
a
,
C
A
,
9
0
4
0
4
P
H
O
N
E
:
(
3
1
0
)
8
7
6
-
8
5
0
5
F
A
X
:
(
9
1
9
)
7
4
7
-
5
6
3
9
E
M
A
I
L
:
r
e
g
8
1
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
Ar
c
a
d
i
a
,
C
A
,
9
1
0
0
7
I
N
T
E
R
I
O
R
D
E
S
I
G
N
M-5
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
HO
O
D
I
N
F
O
R
M
A
T
I
O
N
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
§GREASE DUCT SPECIFICATIONS:
PROVIDE GREASE DUCT EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW"
ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK. MODEL "DW"
IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP LOCKING
CONNECTIONS SEALED WITH 3M FIRE BARRIER 2000 PLUS. MODEL "DW"
DOES NOT REQUIRE WELDING PROVIDING IT HAS BEEN INSTALLED PER
THE MANUFACTURES INSTALLATION GUIDE.
PROVIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTION AND EVERY 12' ON CENTER. PER MANUFACTURES LISTING
MODEL "DW" HORIZONTAL RUNS LESS THAN 75 FT. CAN BE SLOPED 1/16" PER 12", HORIZONTAL RUNS MORE THAN 75 FT. CAN
BE SLOPED 3/16" PER 12".
DUCT SHOULD BE SLOPED AS MUCH AS POSSIBLE TO REDUCE THE CHANCE OF GREASE ACCUMULATION IN HORIZONTAL
RUNS.
IF THE DUCT IS WITHIN 18 INCHES OF COMBUSTIBLE MATERIAL, PROVIDE UL-2221 LISTED DOUBLE WALL GREASE DUCT EQUAL
TO CAPTIVEAIRE SYSTEMS MODEL "DW- 2R, 3R, OR 3Z" ROUND 20 GAUGE 430 STAINLESS INNER DUCT INSULATED WITH A 24
GAUGE 430 STAINLESS OUTER SHELL.
CAPTIVEAIRE SYSTEMS RECOMMENDS THE USE OF LISTED, PRE-FABRICATED ROUND GREASE EXHAUST DUCT TO REDUCE STATIC
PRESSURE IN THE SYSTEM, MINIMIZE INSTALLATION AND INSPECTION TIMES, AND ENSURE DUCT IS LIQUID TIGHT
The Double Wall Ductwork Series has been certified by ITS. This certification mark indicates that the product has been tested to and has met the
minimum requirements of a widely recognized (consensus) U.S. Product safety standard, that the manufacturing site has been audited, and that the
applicant has agreed to a program of periodic factory follow-up inspections to verify continued performance.
Models DW-2R and DW-3R are ETL Listed under file number 1000082319SAT-006 EEV and comply with UL1978 and UL2221 Standards.
Model DW-3Z is ETL Listed under file number 1000082319SAT-006 EEV and complies with UL1978, UL2221 and CAN/ULC-S144 Standards.
SINGLE WALL FACTORY BUILT DUCTWORK
- FOR A COMPLETE LIST OF APPROVED SUPPORT METHODS, SEE THE INSTALLATION AND OPERATION MANUAL.
- DUCTWORK SHALL SLOPE NOT LESS THAN 1/16" PER LINEAR FOOT TOWARDS THE HOOD OR AN APPROVED GREASE COLLECTION RESERVOIR.
- WHERE HORIZONTAL DUCTS EXCEED 75 FEET IN LENGTH, THE SLOPE SHALL NOT BE LESS THAN 3/16" PER LINEAR FOOT.
- ALL DUCTWORK IS REQUIRED TO BE INSTALLED WITH THE MAXIMUM SUPPORT SPACING LISTED BELOW.
DUCT DIAMETER
8"10'10'24'
10"10'10'24'
12"10'10'24'
14"10'10'24'
16"10'10'24'
18"10'10'24'
20"10'10'24'
22"10'10'24'
24"10'10'24'
HORIZONTAL
SUPPORT (ft)
VERTICAL
WALL SUPPORT (ft)
VERTICAL
CURB SUPPORT (ft)
HORIZONTAL VERTICAL
TYPE
DUCT DIAMETER SUPPORT SPACING (ft)
2R & 2R HT
8"7'
10"7'
12"7'
14"7'
16"7'
18"5'
20"5'
22"5'
DOUBLE WALL FACTORY BUILT DUCTWORK
- ALL DUCTWORK IS REQUIRED TO BE INSTALLED WITH THE MAXIMUM SUPPORT SPACING LISTED BELOW.
- FOR A COMPLETE LIST OF APPROVED SUPPORT METHODS, SEE THE ENTIRE INSTALLATION AND OPERATION MANUAL
- DUCTWORK SHALL SLOPE NOT LESS THAN 1/16" PER LINEAR FOOT TOWARDS THE HOOD OR AN APPROVED GREASE COLLECTION RESERVOIR.
- WHERE HORIZONTAL DUCTS EXCEED 75 FEET IN LENGTH, THE SLOPE SHALL NOT BE LESS THAN 3/16" PER LINEAR FOOT.
24"5'
WALL
SUPPORT (ft)
CURB
SUPPORT (ft)
FLOOR
SUPPORT (ft)
20'24'24'
3R 10'24'24'
3Z 10'24'24'
Furnish double wall, factory built grease duct for use with Type I kitchen hoods, which conforms to the requirements of NFPA-96. Products shall be ETL listed to UL-1978
and UL-2221 for venting air and grease vapors from commercial cooking operation. Models DW-2R, 3R and 3Z are used for grease duct applications when installed in
accordance with these instructions and National Fire Protection Association "NFPA 96"; Standard for Ventilation Control and Fire Protection of Commercial Cooking
Operations. Double wall grease ducts are listed for a continuous internal temperature of 500 degrees F and intermittent temperatures of 2000 degrees F.
The duct sections shall be constructed of an inner duct wall and an outer wall with insulation in between. The inner duct wall shall be constructed of .036 inch thick, 430 type
stainless steel and be available in diameters 8" through 24". The outer wall shall be constructed of stainless steel at a minimum of .024 inch thickness. The duct, based on
model number, shall include layers of Super Wool 607 Plus insulation between the inner and outer wall. Grease duct joints shall be held together by means of formed V
clamps and sealed with 3M Fire Barrier 2000+. The duct wall assembly shall be tested and listed at ¾" or zero inch clearance, according to classifications.
Classifications and Clearances
UL 2221: Standard for Fire Resistive Grease Duct Enclosure Assemblies. Chapter 7 of this standard references a test labeled Internal Fire Test. Section 7.1.1 references two
installation conditions, Condition A and Condition B. Condition A represents all installation condition except for installation within non-ventilated combustible enclosures.
Condition B represents installation within a non-ventilated combustible enclosure.
Model DW-2R is classified under UL2221 (Test of Fire Resistive Duct Enclosure Assemblies) as an alternate to 2-Hr. fire resistive shaft enclosures with a reduced clearance
to combustibles (sizes 8" to 16" diameter). Model 2R is listed in accordance with the requirements for duct enclosure Condition B.
AIR
F
L
O
W
AIR
F
L
O
W
18 - DOUBLE V BAND FOROUTER SHELLPART # DW14DWCLASY-2
Exhaust fan
Vented curb per NFPA-96
Adjustable Duct
Adjustable collar
Fan adapter plate
with ceramic gasket
Standard duct
Inner V-clamp
Outer double V-clamp
Insulated riser cover
Riser
Vertical support assembly.
See installation manual for
requirements.
Insulated cleanouts to be provided in
accordance with all state and local
code requirements.
Adjustable ducts are used on runs over 100ft to
compensate for thermal expansion. See
installation manual for requirements.
Horizontal support assembly - see
installation manual for requirements.
HOOD
Duct run shown is for example purposes only.
See mechanical plans for additional information.
See installation manual
for minimum overlap
requirements.
Additional information including installation manual available at
www.captiveaire.com.
DOUBLE WALL GREASE DUCT WRITTEN SPECIFICATION
SHELL OD
SHELL OD+ .462"
8
8
COMBUSTIBLE
SURFACE
DUCT
DOUBLE V-BAND
3/4" REDUCED
CLEARANCE
FOR TEMPERATURE SENSOR
(IF APPLICABLE)
MAXIMUM
SPACING (FT)
VERTICAL SUPPORT
MAXIMUM SPACING (FT)
DUCT DIAMETER
20"
18"
24"
10'
10'
10'
12"
14"
16"
8"
10"
10'
10'
10'
10'
10'
LISTED GREASE DUCT.
EXHAUST FAN.
§
HIGH TEMP GASKET IS USED TO
SEAL THE FAN TO THE
TRANSITION PLATE.
VENTED CURB ROOF
TERMINATION.
THE INNER DUCT IS FULLY WELDED TO
THE TRANSITION PLATE, ALL WELDS ARE
DYE TESTED.
SECURED TO THE
CURB BY OTHER.
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No.
9
6
BU
I
L
T
NF
P
A
WIT
H
IN
SLI
D
TE
R
5700997
MASTER DRAWING
asw-81
Pa
r
i
s
B
a
g
u
e
t
t
e
-
A
r
c
a
d
i
a
,
C
A
17
L
a
s
T
u
n
a
s
D
r
i
v
e
,
Lo
s
A
n
g
e
l
e
s
O
f
f
i
c
e
18
1
0
1
4
t
h
S
t
S
u
i
t
e
2
1
4
,
S
a
n
t
a
M
o
n
i
c
a
,
C
A
,
9
0
4
0
4
P
H
O
N
E
:
(
3
1
0
)
8
7
6
-
8
5
0
5
F
A
X
:
(
9
1
9
)
7
4
7
-
5
6
3
9
E
M
A
I
L
:
r
e
g
8
1
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
Ar
c
a
d
i
a
,
C
A
,
9
1
0
0
7
I
N
T
E
R
I
O
R
D
E
S
I
G
N
M-6
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
HO
O
D
I
N
F
O
R
M
A
T
I
O
N
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
- VARIABLE SPEED CONTROL.
- THERMAL OVERLOAD PROTECTION (SINGLE PHASE).
- HIGH HEAT OPERATION 300°F (149°C).
EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING AIR AT 300°F (149°C)
UNTIL ALL FAN PARTS HAVE REACHED
THERMAL EQUILIBRIUM, AND WITHOUT ANY
DETERIORATING EFFECTS TO THE FAN WHICH
WOULD CAUSE UNSAFE OPERATION.
NORMAL TEMPERATURE TEST
22 1/2"
24 3/4"
31 7/8"
14 7/8"
2"
23"
- INTERNAL WIRING.
- ROOF MOUNTED FANS.
- RESTAURANT MODEL.
FEATURES:
- DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS).
31 7/8"
24 3/4"
- NEMA 3R SAFETY DISCONNECT SWITCH.
30 1/2"
GREASE DRAIN.
- GREASE CLASSIFICATION TESTING.
- UL705 AND UL762 AND ULC-S645
ABNORMAL FLARE-UP TEST
EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING BURNING GREASE VAPORS
AT 600°F (316°C) FOR A PERIOD OF
15 MINUTES WITHOUT THE FAN BECOMING
DAMAGED TO ANY EXTENT THAT COULD CAUSE
AN UNSAFE CONDITION.
3" FLANGE.
22 1/2"
22 1/2"
ROOF OPENING
DIMENSIONS.
20 GAUGE
CONSTRUCTION.
STEEL
20"
23"
23"
VENTED
CURB.
EXAMPLE: 7/12 PITCH = 30° SLOPE.
PITCHED CURBS ARE AVAILABLE
FOR PITCHED ROOFS.
SPECIFY PITCH:
0"
0°
12"
FAN #1 DU85HFA - EXHAUST FAN (EF-1)
OPTIONS
- GREASE BOX.
- FAN BASE CERAMIC SEAL - INSTALLED
AT PLANT - FOR GREASE DUCTS.
- 2 YEAR PARTS WARRANTY.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Label Description Location
MT-01 Fan Motor [3]
SW-01 Main disconnect switch [3]
Component Identification
23
Installed Options
RD - RED
BL - BLUE
WH - WHITE
OR - ORANGE
BR - BROWN
BK - BLACK
PK - PINKPR - PURPLE
GY - GRAY
GR - GREEN
YW - YELLOW
WIRE COLOR
DENOTES FIELD WIRINGDENOTES INTERNAL WIRING
NOTES
SW-01
BK
BK
MT-01
GR
BK
GR
BK
BK
BK
5 6
3 4
1 2
GR
EXHAUST 0.75HP-208V-3P-2.6FLAVFD PART: ESV751N02YXB571
MOTOR INFO
ELECTRICAL INFORMATIONMOTOR/CTRL MCA: 3.3AMOTOR/CTRL MOP: 15A
DRAWING NUMBER
JOB
MODELSHIP DATEEXH5700997-1
5700997 - Paris Baguette - Arcadia, CA
10/25/2022
(LEFT)
PLATE
FAN BASE
CURB
FAN
PLATE
(LEFT)
GREASE BOX
(OPTIONAL)
GREASE PIPE
(OPTIONAL)
CURB
"A"
DETAIL
FAN
COMPLETE SWING.
FAN BASE
ATTENTION: INSTALLER SHOULD SUPPLYENOUGH ELECTRICAL CORD TO LET FAN MAKE
GREASE PIPE
CURB
ATTACH GREASE BOX COVER TO THE CURB 3" BELOW
USING (3) LONG (3/4" LG.) SCREWS AS SHOWN.
TOP EDGE OF CURB.
INSTALL GREASE PIPE AS SHOWN.
GREASE BOX
SEPARATOR
GREASE
BOX
COVER
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NFP
A
WIT
H
IN
SLI
D
TE
R
5700997
MASTER DRAWING
asw-81
Pa
r
i
s
B
a
g
u
e
t
t
e
-
A
r
c
a
d
i
a
,
C
A
17
L
a
s
T
u
n
a
s
D
r
i
v
e
,
Lo
s
A
n
g
e
l
e
s
O
f
f
i
c
e
18
1
0
1
4
t
h
S
t
S
u
i
t
e
2
1
4
,
S
a
n
t
a
M
o
n
i
c
a
,
C
A
,
9
0
4
0
4
P
H
O
N
E
:
(
3
1
0
)
8
7
6
-
8
5
0
5
F
A
X
:
(
9
1
9
)
7
4
7
-
5
6
3
9
E
M
A
I
L
:
r
e
g
8
1
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
Ar
c
a
d
i
a
,
C
A
,
9
1
0
0
7
I
N
T
E
R
I
O
R
D
E
S
I
G
N
M-7
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
HO
O
D
I
N
F
O
R
M
A
T
I
O
N
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
BU
I
L
T
IN
5700997
MASTER DRAWING
asw-81
Pa
r
i
s
B
a
g
u
e
t
t
e
-
A
r
c
a
d
i
a
,
C
A
17
L
a
s
T
u
n
a
s
D
r
i
v
e
,
Lo
s
A
n
g
e
l
e
s
O
f
f
i
c
e
18
1
0
1
4
t
h
S
t
S
u
i
t
e
2
1
4
,
S
a
n
t
a
M
o
n
i
c
a
,
C
A
,
9
0
4
0
4
P
H
O
N
E
:
(
3
1
0
)
8
7
6
-
8
5
0
5
F
A
X
:
(
9
1
9
)
7
4
7
-
5
6
3
9
E
M
A
I
L
:
r
e
g
8
1
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
Ar
c
a
d
i
a
,
C
A
,
9
1
0
0
7
FLEX
CONDUIT
FOR FIELD
WIRING.
13 1/4"
11 1/2"
BLOWER DISCHARGE.
CURB.
1 3/4"
3 7/8"
3 3/4"
LIFTING LUG.
AIRFLOW.
BLOWER/MOTOR
ACCESS DOOR
24" SERVICE
CLEARANCE REQ.
SERVICE
DISCONNECT
SWITCH.
AIRFLOW.
18"
16"
Ø1 1/2"
WATER
DRAIN.
AIRFLOW.
Ø1/2" NPT
WATER INLET
WATER FILTER
REQUIRED PROVIDED
BY PLUMBER.
FILTER/CONTROL
ACCESS DOOR.
LPD CELDEK AIRFLOW.
27 3/8"
8 1/4"
21"
12" EQUIPMENT CURB.
32 1/8"
29 3/4"
21"
32 1/8"
36 3/4"
36 3/4"
ADJUSTABLE
LEG.
64 1/4"
117 7/8"
MIN. 14"
MINIMUM
STRAIGHT
DUCT
PER AMCA*
FAN #2 A1-15D - SUPPLY FAN (KMUA-1)
1. UNTEMPERED SUPPLY UNIT WITH 15" MIXED FLOW DIRECT DRIVE FAN IN SIZE #1 HOUSING.
2. EVAP COOLER (LPD CELDEK) – W/INTAKE HOOD W/EZ FILTERS.
3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT.
4. 120V WIRING CONNECTION TO ENERGIZE EVAPORATIVE COOLERS FROM UNTEMPERED SUPPLY FANS.
5. SEPARATE 120VAC WIRING PACKAGE FOR MAKE-UP AIR UNITS. OPTION MUST BE SELECTED WHEN MOUNTING VFD IN PREWIRE PANEL OR WITH DCV
PACKAGE. PROVIDES SEPARATE 120VAC INPUT TO SUPPLY FAN. THIS 120V SIGNAL MUST BE RUN BY ELECTRICIAN FROM DCV TO MUA SWITCH.
6. HINGED DOUBLE WALL INSULATED DOOR ASSEMBLY (BURNER/BLOWER/EVAP SECTION).
7. 2 YEAR PARTS WARRANTY
*NOTE: SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS. A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED DOWNSTREAM OF
UNIT DISCHARGE AS OUTLINED IN AMCA PUBLICATION 201. WHEN USING RECTANGULAR DUCTWORK, ELBOWS MUST BE RADIUS THROAT, RADIUS BACK WITH
TURNING VANES. FLEXIBLE DUCTWORK AND SQUARE THROAT/SQUARE BACK ELBOWS SHOULD NOT BE USED. ANY TRANSITION AND/OR TURNS IN THE
DUCTWORK WILL CAUSE SYSTEM EFFECT. SYSTEM EFFECT WILL DRASTICALLY INCREASE STATIC PRESSURE AND REDUCE AIRFLOW. DO NOT RELY ON UNIT
TO SUPPORT DUCT IN ANY WAY. FAILURE TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT.
SUGGESTED STRAIGHT DUCT SIZE IS 14" x 14".
L ETS DI
R
ROOF OPENING 2" SMALLER THAN CURB DIMENSION.
5"
5"
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
WIRE COLOR
BK - BLACKBL - BLUEBR - BROWNOR - ORANGERD - REDWH - WHITE
YW - YELLOW
GR - GREEN
NOTES
DENOTES FIELD WIRING
DENOTES INTERNAL WIRING
GY - GRAY
Label Description Location
Component Identification
23
PR - PURPLEPK - PINK
Installed Options
SW-01R
W
B
GR
VA-01
11
BK
BL
N
WH
11 BK
[BK][WH]
N
WH
Spray Timer
Overflow Switch
Thermostat
Internal Solenoid Valve
SW-02
SW-01
VA-01TI-01 [5-7]
[6]
[2]
[5]
GR
D CSW-02NC TI-01
A1 A2TORBK WH N
TI-01
1815 SV
BL
BR OR
PRESSURE
OVERFLOWSWITCH
To buildingdrain
Field Wiredand Piped
From buildingwater supplyNormally closed valve
B W
Roof line
R
WB
R
SWITCH
AE
Normally open valve
InternalWaterSolenoid
TIMER
15
A1
18
A2
16
P
If cable is CM1NO2VL2BO2
NOTE:
change
BK->BR & WH->BL
JUMPER A1 AND B1
FOR RZ7-FSH3VU23 TIMER
JUMPER A1 AND B1FOR
TIMERRZ7-FSH3VU23
DRAWING NUMBER
JOB
MODELSHIP DATE-
Paris Baguette
12/29/2021
SW-01
BK
BK
MT-01
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
GR
BK
GR
Label Description Location
MT-01 Supply motor [2]
SW-01 Main disconnect switch [2]
Component Identification
23
BK
BK
BK
Installed Options
Cooling Interlock
BL
WH
N
11
RD - RED
BL - BLUE
WH - WHITE
OR - ORANGE
BR - BROWN
BK - BLACK
PK - PINK
PR - PURPLE
GY - GRAY
GR - GREEN
YW - YELLOW
WIRE COLOR
DENOTES INTERNAL WIRING
DENOTES FIELD WIRING
NOTES
7 8RD(DCV SF1)WH (DCV N1)
DCV/VFD Wiring
(MAY NOT BE NEEDED DEPENDING ON OPTIONS)IF DCV IS NOT PRESENT, RD AND WH WIRES FROM SEPARATE 120VAC SOURCE
MOCP = 10 AMPS FOR CONTROL WIRING
DROP FOR DISCONNECT CONNECTION
!ATTENTION ELECTRICIAN!
CONNECT POWER TO THE DROP
1 2
5 6
3 4
IS FACTORY SUPPLIED
11
N
SUPPLY 1HP-208V-3P-3.1FLA
MOTOR INFO
ELECTRICAL INFORMATIONMOTOR CIRCUIT MCA: 3.9ACONTROL CIRCUIT MCA: 1.0AMOTOR CIRCUIT MOP: 15ACONTROL CIRCUIT MOP: 15A
DRAWING NUMBER
JOB
MODELSHIP DATE
Paris Baguette
12/29/2021
I
N
T
E
R
I
O
R
D
E
S
I
G
N
M-8
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
HO
O
D
I
N
F
O
R
M
A
T
I
O
N
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
I
N
T
E
R
I
O
R
D
E
S
I
G
N
M-9
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
T-
2
4
F
O
R
M
S
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
I
N
T
E
R
I
O
R
D
E
S
I
G
N
M-10
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
T-
2
4
F
O
R
M
S
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
I
N
T
E
R
I
O
R
D
E
S
I
G
N
P-1
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
LE
G
E
N
D
A
N
D
G
E
N
E
R
A
L
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
19. ALL PIPING INTO STEM WALLS AND FOOTINGS SHALL BE DOUBLE HALF LAP
WRAPPED WITH 1/8" THICK "ARMOFLEX" INSULATION. THE CONTRACTOR
SHALL ALSO PROVIDE BLOCKED OUT AREAS IN STEM WALL AND FOOTING.
OTHER ON SITE PIPING AND EQUIPMENT BY CIVIL AND ELECTRICAL.
20. COORDINATE EXACT LOCATION OF ALL SITE PIPING INDICATED WITH ALL
SHALL BE PROVIDED BY THE CONTRACTOR AND KEPT ON THE JOB SITE.
22. WHERE BRACING DETAILS ARE NOT SHOWN ON THE DRAWINGS OR IN THE
23. A COPY OF THE GUIDELINES PUBLISHED BY SMACNA
GUIDELINES, THE FIELD INSTALLATION SHALL BE SUBJECT TO THE APPROVAL
OF THE DESIGNER & ENGINEER OF RECORD
21. ALL BRACING OF PIPING SHALL BE INSTALLED IN ACCORDANCE WITH SMACNA
GUIDELINES
WITH MATERIALS TO MATCH EXISTING BY THE CONTRACTOR.
ALL PIPING SHALL AVOID THE LOWER 8" OF THE FOOTING.
6. ALL CLEANOUTS SHALL BE INSTALLED WHERE EASILY ACCESSIBLE. THE
EQUIPMENT, CABINETS, ETC., AND THE ARCHITECT PRIOR TO ANY
7. ALL PLUMBING FIXTURE VENTS TO TERMINATE A MIN. OF 12 INCHES
9. UNIONS SHALL BE PROVIDED AND INSTALLED AFTER EACH VALVE AND
FROM ANY VERTICAL SURFACE AND 10 FEET FROM ANY OUTSIDE AIR
EXACT LOCATIONS OF ALL MECHANICAL EQUIPMENT AND EQUIPMENT
LOCATIONS AND REQUIREMENTS SHALL BE COORDINATED IN THE FIELD.
12. ALL CONNECTIONS TO SITE PIPING SHALL BE DONE BY THE PLUMBING
13. ALL WASTE AND VENT PIPING SHALL SLOPE AT 2% UNLESS OTHERWISE
11. BEFORE FABRICATION OR INSTALLATION THIS CONTRACTOR SHALL VERIFY
PROVIDED UNDER ANOTHER SECTION OF SPECIFICATIONS. EXACT ROUGH-IN
8. ALL VALVES, UNIONS, ETC. TO BE SAME SIZE AS PIPE UNLESS INDICATED
CONTRACTOR SHALL COORDINATE ALL CLEANOUT LOCATIONS WITH ALL
SYSTEM NO. W1001. SEE ARCHITECTURAL PLANS FOR ALL WALL LOCATIONS.
17. PIPING THROUGH FIRE RATED WALLS SHALL BE PER U.L. FIRE RESISTANCE
14. ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTERS OR OTHER
EQUIPMENT SHOWN IN WALLS OR ABOVE NON-ACCESSIBLE CEILINGS
15. ALL PLUMBING FIXTURES AND EQUIPMENT SHALL BE CERTIFIED BY THE
CALIFORNIA STATE ENERGY COMMISSION TO COMPLY WITH EFFICIENCY
STANDARDS PER SECTION 2-5314(A) OF THE TITLE-24 REGULATIONS.
16. ALL HOT WATER PIPING SHALL BE INSULATED TO A MINIMUM THERMAL
18. ALL EXISTING PIPING DAMAGED DURING EXCAVATION SHALL BE REPAIRED
INDICATED ON THE PLANS.
RESISTANCE VALUE OF R-6 OR GREATER.
CONTRACTOR.
INDICATED ON DRAWINGS.
AND PRIOR TO ALL EQUIPMENT CONNECTIONS.
INSTALLATION.
INTAKES.
FLUSHING LEVERS SHALL BE TO THE WIDE SIDE OF THE STALL.
AND PIPING, AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY
2. EXACT LOCATIONS AND MOUNTING HEIGHTS OF ALL PLUMBING FIXTURES
WALL WITH ALL REQUIRED OFFSETS HAPPENING WITHIN THE WALL.
ENCE WITH ELECTRICAL AND MECHANICAL EQUIPMENT AND STRUCTURAL
MOUNTING HEIGHTS. FURNISH ALL EXPOSED HOT AND COLD WATER AND
PRE-WRAPPED TAILPIECES AND P-TRAPS. ALL ACCESSIBLE WATER CLOSET
1. BEFORE COMMENCEMENT OF WORK, THE CONTRACTOR SHALL VERIFY THE
EXACT LOCATIONS, ELEVATIONS AND CHARACTERISTICS OF ALL UTILITIES
4. TRAPS FOR ALL LAVATORIES AND SINKS SHALL TRAP STRAIGHT BACK TO
5. ALL PLUMBING WORK SHALL BE INSTALLED SO AS TO AVOID INTERFER-
3. SEE ARCHITECTURAL DRAWINGS FOR ACCESSIBLE FIXTURE LOCATIONS AND
DRAIN PIPING BELOW ALL LAVATORIES AND SINKS WITH McGUIRE PROWRAP
SHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS.
DISCREPANCIES OR PROBLEMS.
FRAMING.
24. THE PLUMBING CONTRACTOR SHALL PROVIDE THE WATER, SEWER AND STORM
DRAIN SYSTEMS TO A POINT OF CONNECTION 5'-0" OUTSIDE OF BUILDING
AND SHALL CONNECT AT THE INVERT ELEVATION SHOWN ON THE CIVIL
DRAWINGS. PIPING BEYOND THIS POINT IS SPECIFIED UNDER ANOTHER SECTION
OF THE SPECIFICATION AND SHALL BE AS SHOWN ON THE CIVIL DRAWINGS.
25. ALL UNDERGROUND IRON, COPPER OR STEEL PIPING LOCATED BOTH INSIDE AND
OUTSIDE OF BUILDING SHALL BE ENCASED WITHIN A MINIMUM 10 MIL
POLYETHYLENE PLASTIC SLEEVE SEALED WATER TIGHT WITH POLYVINYL
CHLORIDE TAPE.
26. ALL POINTS OF CONNECTION SHALL BE COORDINATED WITH THE GENERAL
CONTRACTOR PRIOR TO BID.
WHENEVER POSSIBLE.
COLUMN LOCATIONS, PIPING ROUGH-IN SHALL BE STUBBED IN WALLS
6" ABOVE THE FLOOR TO PROVIDE CLEARANCE FOR CLEANING. AT WALL OR
SHALL BE RUN AT THE HIGHEST POSSIBLE ELEVATIONS AND NOT LESS THAN
29. ALL HORIZONTAL PIPING LINES EXTENDED AND CONNECTED TO EQUIPMENT
27. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH AND BE CONSIDERED
TO BE A PART OF SEPARATE AND COMPLETE MECHANICAL SPECIFICATIONS.
DESIGNATED BY THE OWNER'S REPRESENTATIVE.
INTERRUPTION AND THE ACTUAL SHUT DOWN TIME SHALL BE AT A TIME
SHALL GIVE THE OWNER'S REPRESENTATIVE SUFFICIENT NOTICE OF SUCH
INTERRUPTION TIME WILL BE AS SHORT AS POSSIBLE. THE CONTRACTOR
28. ALL CONNECTIONS TO EXISTING SERVICES SHALL BE MADE SUCH THAT
30. ALL CUTTING OF EXISTING PAVINGS, WALKS AND/OR FLOORS SHALL BE BY
MACHINE SAW CUTTING. HOLES FOR PIPES IN CONCRETE WALLS OR FLOORS
SHALL BE DONE BY CORE DRILLING EQUIPMENT.
YB
CFH CUBIC FEET PER HOUR
YARD BOX
(E)V
(E)HW
(E)W
SOV IN YB
(E)CW
S OR W
S OR W
DN
BEL
ABV
W/
CLG
FLR
CONN
I.E.
AP
POC
VTR
COTG
GC
CV
SOV
COYB
WCO
G
(E)G
G
FCO
HW
CD
EV
CW
CD
V
DOWN
BELOW
ABOVE
WITH
CEILING
FLOOR
VENT THRU ROOF
POINT OF CONNECTION
CONNECTION
INVERT ELEVATION
ACCESS PANEL
CLEANOUT TO GRADE
WALL CLEANOUT
CLEANOUT IN YARDBOX
SHUT-OFF VALVE IN YARD BOX
CHECK VALVE
SHUT-OFF VALVE
GAS COCK
EXISTING HOT WATER
EXISTING COLD WATER
GAS (LOW PRESSURE)
EXISTING GAS
HOT WATER
FLOOR CLEANOUT
EXISTING SANITARY VENT
EXISTING SOIL OR WASTE
SANITARY VENT
COLD WATER
CONDENSATE DRAIN
SOIL OR WASTE (BELOW GRADE)
SOIL OR WASTE (ABOVE GRADE)
ABOVE GROUND PIPING SYSTEMS SHALL BE MARKED IN ACCORDANCE WITH
ASME A13.1.
31.
CAP AND ABANDON ALL EXISTING WASTE PIPING BELOW FLOOR EXCEPT INDICATED TO BE
REUSED. ROUTER AND CLEAN ALL EXISTING WASTE PIPING TO BE REUSED.
EXISTING PIPING ABOVE CEILING AND IN EXISTING WALLS BEING DEMOLISHED,
THAT IS NOT BEING REUSED, SHALL BE REMOVED. COORDINATE EXTENT OF
DEMOLITION WITH THE ARCHITECT AND THE GENERAL CONTRACTOR.
THE CONTRACTOR SHALL VERIFY THE EXACT DEPTH AND LOCATION OF EXISTING
DRAINAGE SYSTEM LATERALS PRIOR TO INSTALLATION OF ANY PIPING.
ALL FIXTURES, EQUIPMENT, PIPING AND MATERIAL SHALL BE LISTED.
ALL PLUMBING FIXTURES SHALL MEET THE FLOW REQUIREMENTS SPECIFIED IN
THE CITY OF ARCADIA PLUMBING CODE.
ALL FAUCETS IN PUBLIC RESTROOMS SHALL BE SELF CLOSING OR SELF CLOSING
METERING.
PUBLIC LAVATORIES SHALL HAVE CONTROLS TO LIMIT THE WATER TEMPERATURE
TO 110F
WATER PIPING AND FITTINGS WITH LEAD CONTENT WHICH EXCEED 0.25% SHALL
BE PROHIBITED IN SYSTEMS CONVEYING POTABLE WATER.
32.
33.
34.
10.ALL WORK SHALL BE PERFORMED AND ALL MATERIALS SHALL BE INSTALLED IN
COMPLIANCE WITH THE FOLLOWING CODES AS ADOPTED AND AMENDED BY
THE INSPECTING AUTHORITY. NOTHING IN THESE DRAWINGS IS TO BE
CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES OR
OTHERS APPLICABLE TO THIS PROJECT:
PRE-CONSTRUCTION MEETING IS REQUIRED BY INSPECTION. TO SCHEDULE MEETING, CALL
INSPECTIONS SUPERVISOR
1.
2.ALL PIPE, FITTINGS, FIXTURES, ETC THAT CONTACT PORTABLE WATER FOR HUMAN
CONSUMPTION SHALL SHOW APPROVAL TO NSF 61, ANNEX G. REFERENCE SECTION 604.10,
CALIFORNIA PLUMBING CODE, 2019 EDITION AND HEALTH AND SAFETY CODE SECTION 116875.
3.EQUIPMENT ON CASTERS SHALL BE INSTALLED IN ACCORDANCE WITH THEIR LISTING AND THE
ACCOMPANYING MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR LIMITING THE
MOVEMENT OF THE EQUIPMENT TO PREVENT STRAIN ON THE (FUEL) CONNECTION. SECTION
913.6, 2019 CPC.
ALL PLUMBING FIXTURES ON PLUMBING FIXTURE AND EQUIPMENT SCHEDULE
MEET THE REQUIREMENTS OF CALIFORNIA GREEN CODE, INCLUDING ITEMS
NOTED IN CHAPTER 5, DIVISION 5.3 ; WATER EFFICIENCY AND CONSERVATION:
WATER REDUCTION 5.303.2.2
WATER CONSERVING PLUMBING FIXTURES AND FITTINGS 5.303.3
WATER CLOSETS 5.303.3.1
URINALS 5.303.3.2
WASTEWATER REDUCTION 5.303.4
STANDARDS FOR PLUMBING FIXTURES AND FITTINGS 5.303.6
.CPC CHAPTER 14
35.
36.
37.
38.
39.
FLUID
TEMPERATURE
RANGE
(°F)
ABOVE 350
SPACE HEATING, HOT WATER (STEAM, STEAM CONDENSATE & HOT WATER) AND SERVICE WATER HEATING SYSTEMS
251 - 350
141 - 200
105 - 140
CONDUCTIVITY
RANGE
(IN BTU-INCH PER HOUR
PER SQUARE FOOT PER °F)
INSULATION MEAN
RATING TEMPERATURE
(°F)
NOMINAL PIPE DIAMETER (IN INCHES)
INSULATION THICKNESS REQUIRED
(IN INCHES)
<1
1
TO
<1.5
TO
<4
1.5
TO
<8
41 8
AND
LARGER
TO
0.32 - 0.34
0.29 - 0.31
0.27 - 0.30
0.25 - 0.29
0.22 - 0.28
250
200
150
125
100
4.5
3.0
2.5
1.5
1.0
5.0
4.0
2.5
1.5
1.5
5.0
4.5
2.5
2.0
1.5
5.0
4.5
3.0
2.0
1.5
5.0
4.5
3.0
2.0
1.5
SPACE COOLING SYSTEMS (CHILLED WATER, HVAC SYSTEMS, HVAC CONDENSATE, REFRIGERANT AND BRINE)
40 - 60 0.21 - 0.27 75 0.5 0.5 1.0 1.0 1.0
BELOW 40 0.20 - 0.26 50 1.0 1.5 1.5 1.5 1.5
201 - 250
TABLE 120.3-A PIPE INSULATION THICKNESS
1.CONTRACTOR TO PROVIDE COMPLETE SEISMIC ANCHORAGE AND BRACING FOR ALL MECHANICAL EQUIPMENT THAT IS DIRECTLY MOUNTED ON
THE FLOOR OR ROOF AND ALL MECHANICAL EQUIPMENT THAT IS SUSPENDED FROM THE FLOOR, WALL OR SUPPORTED BY VIBRATION
ISOLATORS TO RESIST A HORIZONTAL FORCE ACTING IN ANY DIRECTION USING THE CRITERIA OUTLINED IN THE CALIFORNIA BUILDING CODE,
REFER TO CHAPTER 16A. PROVIDE ANCHORAGE CALCULATIONS AND DETAILS CERTIFIED BY A STRUCTURAL ENGINEER REGISTERED IN THE
STATE OF CALIFORNIA. THE INSTALLATION SHALL BE SUBJECT TO THE APPROVAL OF THE STRUCTURAL ENGINEER AND WITH ALL APPLICABLE
AMENDMENTS AND FIRE DEPARTMENTS.
2.CONTRACTOR TO PROVIDE COMPLETE SEISMIC BRACING AND ANCHORAGE OF ALL PIPING AND DUCTWORK. BRACING AND ANCHORAGE SHALL
CONFORM TO MASON INDUSTRIES"SEISMIC RESTRAINT GUIDELINES FOR SUSPENDED PIPING, DUCTWORK AND ELECTRICAL SYSTEMS", I.S.A.T.
OPA-0485 "ENGINEERED SEISMIC BRACING OF SUSPENDED UTILITIES", SMACNA "GUIDELINES FOR SEISMIC RESTRAINTS OF MECHANICAL
SYSTEMS", OR OTHER PRE-APPROVED SYSTEMS.
3.ALL PIPING, DUCTWORK AND CONDUIT CROSSING BUILDING SEISMIC SEPARATIONS SHALL BE PROVIDED WITH APPROVED FLEXIBLE
CONNECTORS.
AMERICAN STANDARD "LUCERNE" NO.
355.012 WALL MOUNTED LAVATORY
FAUCET CHICAGO NO. 844-665PSHCP,
GRID STRAINER DRAIN, OFFSET
TAILPIECE, LA PATTERN P TRAP, LOOSE
KEY ANGLE STOPP 1
4 TURN. PROVIDE
TRUEBRO "HANDI LAV-GUARD #102 KIT.
BRADLEY POINT OF USE MIXING VALVE
S59-4000
ADVANCE-TABCO WALL MOUNTED
SERVICE SINK MODEL FC-WM-2219-F
WITH FAUCET AMERICAN STANDARD
FAUCET 8350.243 WITH INTEGRAL
VACUUM BREAKER. PROVIDE GRID
STRAINER AND 3" TRAP
AMERICAN STANDARD "CADET" MODEL
2403.128 ELONGATED BOWL, VITREOUS
CHINA, 1.28 GPF, WITH VACUUNM
BREAKER, TOILET SEAT OLSONITE NO.
95 OPEN FRONT.
NO
T
E
S
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
I
N
T
E
R
I
O
R
D
E
S
I
G
N
P-1.1
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
KI
T
C
H
E
N
E
Q
U
I
P
M
E
N
T
P
L
A
N
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
SYMBOL SERVICE LOCATION
KITCHEN AREA
MANUFACTURER &
MODEL NO.
(2)NORITZ MODEL
NCC199
INPUT
BTU/HR
199,000
GAS
TYPE
NATURAL
EWT
DG °F
60 140
LWT
DG °F
GPM RECOVERY
@ 80 TEMP RISE
4.8
VENT
DIAMETER
4"70
OPERATING
WEIGHT
(LBS)
LOW NOX. INSTANTANEOYS WATER HEATER, 115V, 1Ø,
60HZ., 2 AMPS. PROVIDE CONDENSATE NEUTRALIZER,
CONTROLLER.
REMARKS
SERVICES LOCATION
DOMESTIC COLD
& HOT WATER
UNDERGROUND
ABOVE GROUND
MATERIAL
RIGID COPPER (TYPE K)
JOINING
METHOD
REMARKS
RIGID COPPER (TYPE L)
SANITARY WASTE
SEWER
UNDERGROUND
ABOVE GROUND
SANITARY WASTE
VENT
ABOVE GROUND &
BELOW GROUND
CAST IRON SOIL PIPE & FITTINGS OR
LOW PRESSURE
GAS
UNDERGROUND
ABOVE GROUND
SCHEDULE 40 BLACK STEEL WRAPPED 10MIL
SCHEDULE 40 BLACK STEEL
STORM DRAIN UNDERGROUND
ABOVE GROUND
CAST IRON SOIL PIPE
CAST IRON SOIL PIPE
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019
313.0 AND 313.10.
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019
313.0 AND 313.10.
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019
313.0 AND 313.10.
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019
313.0 AND 313.10.
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019
313.0 AND 313.10.
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019
313.0 AND 313.10.
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019
313.0 AND 313.10.
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019
313.0 AND 313.10.
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019
313.0 AND 313.10.
NOTE: ALL BRAZED AND SOLDERED JOINTS SHALL BE LEAD FREE. ABS PIPE SOLID WALL AND PVC PIPE AND FITTINGS CAN BE USED ONLY
WHEN FIRST APPROVED BY AHJ.
1/6 1120 60
REMARKSHZØVHP
MOTOR
2010-30
TDH
HEADGPM
CAPACITY
AND MODEL NO.
MANUFACTURER SERVICESYMBOLLOCATION
BELL AND GOSSETT ALL BRONZE CONSTRUCTION
SERVEDSYMBOLAREA LOCATION MANUFACTURER
AND MODEL NO.
MAXIMUM
OPERATING
PRESSURE PSI
MAXIMUM
ACCEPTANCE
VOLUME(GAL.)
DIAMETER/
HEIGHT
(INCHES)
OPERATING
WEIGHT
(LBS.)
WATER
HEATER
AMTROL
THERM-X-
TROL
ST-12
3.2 11"X
15"40 -
REMARKS
KITCHEN
KITCHEN HOT WATER
RETURN
150
DOMESTIC
HOT WATER
GREASE INTERCEPTOR SCHEDULE
ITEM
HOT WATER
-----GI
1
--
VENTWASTE
2"4"--
ROUGH-IN CONNECTIONSFIXTURE DESCRIPTION
TRAP COLD WATER GAS CFH DESCRIPTION
JENSEN GREASE INTERCEPTOR MODEL
JP750G, 750 GALLON TANK, WITH SAMPLING
BOX, TRAFFIC RATED, PROVIDE ADJUSTING
RINGS, C.I. MANHOLE COVERS, VENT.
GREASE INTERCEPTOR
2019 CPC TABLE 1215.2(1) NFPA 54 TABLE 6.2(b)
MAXIMUM DELIVERY CAPACITY OF SCHEDULE 40 METALLIC PIPE CARRYING NATURAL GAS OF 0.60 SPECIFIC
GRAVITY BASED ON A PRESSURE DROP OF 0.5" WATER COLUMN, GAS PRESSURE 8" WC
PIPE SIZE IN INCHES
NOMINAL ID 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3
LENGTH (FT)CAPACITY IN CUBIC FEET OF GAS PER HOUR
10 172 360 678 1,390 2,090 4,020 6,400 11,300
20 118 247 466 957 1,430 2,760 4,400 7,780
30 95 199 374 768 1,150 2,220 3,530 6,250
40 81 170 320 657 985 1,900 3,020 5,350
50 72 151 284 583 873 1,680 2,680 4,740
60 65 137 257 528 791 1,520 2,430 4,290
70 60 126 237 486 728 1,400 2,230 3,950
80 56 117 220 452 677 1,300 2,080 3,670
90 52 110 207 424 635 1,220 1,950 3,450
100 50 104 195 400 600 1,160 1,840 3,260
125 44 92 173 355 532 1,020 1,630 2,890
150 40 83 157 322 482 928 1,480 2,610
1.ALL GAS PIPING DOWNSTREAM OF PRESSURE REGULATOR TO BE SIZED PER CPC TABLE 1216.2(1)
2.GAS METERS TO BE ACCESSIBLE. INSTALL AUTOMATIC EARTHQUAKE SHUT-OFF VALVE & REGULATOR AS REQUIRED.
3.GAS SHUT-OFF VALVES & PRESSURE REGULATORS TO BE EASILY ACCESSIBLE.
4.GAS METER LOCATIONS VARY. PLUMBING CONTRACTOR TO COORDINATE GAS PIPE ROUTING FROM GAS METERS
TO ANY STEP-DOWN PRESSURE REGULATORS.
175 37 77 144 296 443 854 1,360 2,410
200 34 71 134 275 412 794 1,270 2,240
250 30 63 119 244 366 704 1,120 1,980
4
23,100
15,900
12,700
10,900
9,660
8,760
8,050
7,490
7,030
6,640
5,890
5,330
4,910
4,560
4,050
LOW PRESSURE NATURAL GAS PIPE SIZING TABLE
SOLID WALL ABS PIPE AND FITTINGS
CAST IRON SOIL PIPE & FITTINGS OR
SOLID WALL ABS PIPE AND FITTINGS
CAST IRON SOIL PIPE & FITTINGS OR
SOLID WALL ABS PIPE AND FITTINGS
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
NSITE PLAN
Scale: 1/8"=1'-0"
PARIS BAGUETTE
7 LAS TUNAS DR.ARCADIA CA 91007
LA
S
T
U
N
A
S
D
R
I
V
E
EXISTING
PARKING
EXISTING
PARKING
EXISTING
PARKING
EXISTING
PARKING
EXISTING
PARKING
I
N
T
E
R
I
O
R
D
E
S
I
G
N
P-1.2
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
PL
U
M
B
I
N
G
S
I
T
E
P
L
A
N
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
(E) SAMPLING BOX DETAIL
(E) GREASE INTERCEPTOR DETAIL
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
(N)F.S.
(N)F.S.
(N)F.S.
(N)F.S.
(N)F.S.
(N)F.S.
01KITCHEN EQUIPMENT PLAN
Scale: 1/4" = 1'-0"
1
AB
2
3
21A
PATIO
SEATING AREA
(N)F.S.
(N)F.S.
(N)F.S.
(N)F.S.
(N)F.S.
(N)F.S.
3'-0"
49VL5GLG
CAKE STORAGE REFRIGERATOR 1
35600.0020BUNN1
CONVECTION OVEN 1
TUC-60TRUE1UNDERCOUNTER REFRIGERATOR 60" (TR)
CAKE PREP FRIDGE 48"2
UD-0310A1MANITOWICUNDERCOUNTER ICE MACHINE
COFFEE BREWER BUNN 53200.01011
TGM-22RV(B)-N6TURBO AIR
UNDERCOUNTER REFRIGERATOR 60"TURBO AIR JUR-60S-N6
GRINDER
DISPLAY CASE REFRIGERATED 60"1 TCGB-60UF-B-N
DECK OVEN (3 DECK)1 PARIS CROISSANT SD-3
4TV
2POS TOAST TOAST FLEX
1STAINLESS STEEL WORK TABLE 48"WT-EB3048
1STAINLESS STEEL WORK TABLE 36"
5' CUTTING BOARD W/L CLIP 1 CUTTING BOARD
1DROP IN HAND SINK
PREP. SINK 1 1B184-1D18R
3 COMPARTMENT SINK 1 60053242418G
HS-1317
TURBO AIR
NITRON COLD DRAFT SCHOLL COFFEE MACHINE 1 BUNN WRDG-51600.0020
1
2
3
5
6
7
8
10
11
12
13
14
15
16
17
18A
19
20
20A
21
22
23
24
25A
26
27
28
29
30
31
33
34
35
35A
36
37
38
39
40
41
42
43
1 PARIS CROISSANTDECK OVEN STAND
BREAD RACK (TALL)1 PARIS CROISSANT
CONVECTION OVEN (2 DECK)1 MOFFAT TURBOFAN
1 MOFF-E35D6-26/2CCONVECTION OVEN STAND MOFFAT TURBOFAN
3 TDC-30-2RNEW DOUGH CONDITIONER TURBO AIR
GRAB AND GO BEVERAGE 1 TURBO AIR TOM-50-B-N
1 TCGB-48UF-B-NTURBO AIRDISPLAY CASE REFRIGERATED 48"
SANDWICH PREPARATION REFRIGERATOR 1 MST-72-NTURBO AIR
1
THERMAL DISPENSER BUNN 42700.02002
BLENDER, BAR BLENDTEC S885C2901-B1GB1D2
DONUT FRYER
CAKE MIXER KSM8990WH
MICROWAVE OVEN (UNDERCOUNTER)NE-1025F
BREAD SLICER
ESPRESSO MACHINE
2PITCHER RINSER BLENDTEC RAPID RINSER
EMPLOYEE LOCKER 2
HAND SINK JOHN BOOS PBHS-W-1410-P-SSLR2
44
16"x20"x12"CHEMICAL SHELVE & MOP RACK
27.9"X22"X23.6"
13.3"X14.6"X16.5"120V, 500W, 60HZ
20.25"X16.5"X12"NSF
NSF
60 3/8"x30 1/8"x29 3/4"UL, NSF
NSF, ETL8.6"X9"X17.3"120V/220V-, 3.8HP
208V-, 30APROVIDE WATER FILTER SYSTEMPROVIDE APPROVED BACKFLOW PREVENTER FLOOR SINKINDIRECT
59"X27 1/2"X28 3/4"ETL 2.5" CASTER
72 5/8"X30"X37"UL, NSF 5" CASTER 115V-, 5.7AMP, 2/5HP
120V-, 13.5AMP
2.5" CASTER 115V, 5.1A 1/5HP
13"X17 1/2"X6 3/8"NSF 1/2"1/2"DIRECT
112"X29.5"X43.75"NSF
1/2"1/2"DIRECT
6" LEG 1/2"1/2"
PROVIDE APPROVED BACKFLOW PREVENTER
ETL
48 1/2"X34 1/4"X50 1/8"NSF 115V- 7.5A, 1/3HP4" CASTER
28 3/4"X27 5/8"X79 7/8"115V, 2.2A 1/5HPETL4" CASTER
23.9"X26.8"X34.6"120V-, 7.3AMP
14"X10"X5"NSF 1/2"1/2"DIRECT
18"X18"X14"NSF 6" LEG PROVIDE APPROVED BACKFLOW PREVENTER
FOLLOWING C.D INDIRECT FLOOR SINK1/2"1/2"
DIRECTW/ 18" DRAIN BD.
FOLLOWING C.D.
NSF
1
1
3
1
KTCHNNAID
PANASONIC
TURBO CHEF ECO
SPE-203-161825
MOFF-E35D6-26/2
THE ECO
65"x42"x21"5" CASTER 220V, 3PH, (3) 40AMPINDIRECTFLOOR SINKUL, NSF PROVIDE APPROVED BACKFLOW PREVENTER
1
1
JAC
EVERSYS
PICOMATIC
E4
MOP SINK45
46B
46C
WALL MOUNT SHELF 36"1836NK3-METROSEAL
WALL MOUNT SHELF 36"1436NK3-METROSEAL
5
3
METRO SUPER ERECTA
METRO SUPER ERECTA
EAGLE F1916-12 & 312690
EL-5DR
KROWNE
JOHN BOOS
REGENCY
1
54
55
STANDING SHELF (CHROME) 18" x 36"
STANDING SHELF (CHROME) 18" x 48"
70
71
STANDING SHELF (GREEN) 18" x 48"
STANDING SHELF (GREEN) 18" x 60"
2WALL MOUNT SHELF 24"METRO SUPER ERECTA 1824NK3-METROSEAL
86
86A
87
89
STAINLESS STEEL WALL-MOUNTED SHELF 6" x 36"
STAINLESS STEEL WALL-MOUNTED SHELF 6" x 60"
1
1
12X721
90
91
91A
91B
91C
WALL MOUNT SHELF 48" 1848NK3-METROSEAL
WALL MOUNT SHELF 72" 18X72
WALL MOUNT SHELF 72"
1
2
METRO SUPER ERECTA
1
2
14X72
12X72
STAINLESS STEEL WALL-MOUNTED SHELF 6" x 48"1
7
4
5
4
WALL MOUNT SHELF 72"
WALL MOUNT SHELF 72"
NSF 4" CASTER26"X20 1/4"X68 5/8"
50 7/8"X28"X78 1/2"NSF 4" CASTER 115V- 15.5A, 3/4HP
30"X28 1/2"X44 1/2"UL, NSF 6" LEG 115V- 10APROVIDE APPROVED BACKFLOW PREVENTER INDIRECT FLOOR SINK
WHOLE CAKE SHOWCASE, PB LED LIGHT
SHORT CAKE SHOWCASE, PB LED LIGHT
BACK LINE (FAN ON FRONT)
KITCHEN (FAN ON BACK)
PROVIDE WATER FILTER SYSTEM
5-TIER, 12"W x 20"D x 77"H
FOLLOWING C.D.
FOLLOWING C.D.
FOLLOWING C.D.
TUC-48-HC UL48 3/8"X30 1/8"X29 3/4"TRUE 115V-, 3AMP, 1/3HP5" CASTER
35 7/8"W x 77 1/2"H x 36 7/8"D
NSF, ETL35 7/8"W x 77 1/2"H x 36 7/8"D
220-240V, 60Hz, 12.5kW
208V, 60Hz, 11.2kWNSF, ETL
220-240V, 60Hz, 12.5kW
208V, 60Hz, 11.2kW
31 1/2" x 48 3/4" x 77 7/8"ETL 115/60/1
601/2" X 34 1/4" X 50 1/8"NSF 115V- 7.5A, 1/3HP
20.2"W x 22.3"D x 35"H UL, NSF 120V/240V, 60 HERTZ
10"W x 28.4"D x 34"H NSF, ETL 120V, 60 HERTZ
120V, 60 HERTZ9.4"W x 18.6"D x 29.1"H
NSF, ETL
UL, ETL
NSF9.3"W x 13"D x 20.7"H
UL16.1"W x 23.5"D x 21.5"H 208/240 VAC, 60Hz, 20AMP
42.425"W x 3.531"D x 23.929"H
High Mode: 10” x 14” x 8.6
Low Mode: 6.5” x 14” x 8.6”24 Volt
NSF8.8"W x20.5"D x 7.5" H
GSW USA
GSW USA 30"W x 48"L x 35" H
30"W x 36"L x 35" HGSW USA WT-EB3036
NSF
ETL
NSF
ETL
12"W x 20"D x 77" H
18"W x 36"L
14"W x 36"L
NSF
NSF
18"W x 24"L
18"W x 48"L
NSF
NSF
METRO 4'-0"X1'-6"X6'-0"1848 BR 5 TIES - 18" DEPTHNSF6" LEG
1836 BR 3'-0"X1'-6"X6'-0"5 TIES - 18" DEPTH6" LEGNSFMETRO
BLUEAIR 48"X12"WS1248 NSF
BLUEAIR 36"X12"WS1236 NSF
BLUEAIR 60"X12"WS1260 NSF
METRO SUPER ERECTA
METRO SUPER ERECTA
METRO SUPER ERECTA
METRO SUPER ERECTA
METRO SUPER ERECTA
PITCO 15-5/8"X35"X52"120V, 3PH, 0.5AMPETL6" LEG 44,000BTUBNB-SG14
REGENCY 4'-0"X1'-6"X6'-0"NSF 5 TIES - 18" DEPTH6" LEG
REGENCY 5'-0"X1'-6"X6'-0"NSF 5 TIES - 18" DEPTH6" LEG
DUMP SINK 1 NSF -DIRECT
1DIPPER WELL KROWNE 16-149 NSF7 3/16 X 6 3/16 NSFNSF INDIRECT
(FLOOR MOUNTED)
PROVIDE APPROVED BACKFLOW PREVENTER
PROVIDE APPROVED BACKFLOW PREVENTER
PROVIDE APPROVED BACKFLOW PREVENTER
AIR CURTAIN MARS ETL 115V, 9A 1HPAIR VELOCITY MIN.1600FPM (PROVIDED
2389FPM),DOOR SWITCH ACTIVATED TYPE36 "X16"X14"NH-236-1U-TS192
(E)FIXED WINDOW
TO REMAIN (E)FIXED WINDOW
TO REMAIN
(E
)
F
I
X
E
D
W
I
N
D
O
W
TO
R
E
M
A
I
N
01KITCHEN EQUIPMENT PLAN
Scale: 1/4" = 1'-0"
WATER HEATER 1 SEE PLUMBING DRAWING
INDIRECT
STANDING SHELF (GREEN) 18" x 36"2 REGENCY 3'-0"X1'-6"X6'-0"NSF 5 TIES - 18" DEPTH6" LEG
SELF CLOSING
HARDWARE
HS-1317 13"X17 1/2"X6 3/8"KROWNE FOLLOWING C.D.
1/2"CW DOWN IN WALL TO FIXTURE ROUGH IN AND CONNECT
3/4"CW AND 3/4"HW IN WALL TO FIXTURES ROUGH IN AND CONNECT
1/2"CW AND 1/2"HW IN WALL TO FIXTURES ROUGH IN AND CONNECT
1 1/4"CW DOWN TO WATER AND 1 1/4"HW UP FROM WATER HEATER
1" GAS DOWN WITH LINE SIZE SHUT OFF VALVE TO WATER HEATER ROUGH IN AND CONNECT
LINE SIZE AUTOMATIC SHUT OFF VALVE INTERLOCK WITH HOOD FIRE EXTINGUISHING SYSTEM
1/2"ICW UP THROUGH ROOF TO EVAP COOLER ROUGH IN AND CONNECT, PROVIDE LINE SIZE SHUT
OFF VALVE PRIOR TO CONNECTION
PROVIDE LINE ZONE OF REDUCED PRESSURE BACKFLOW PREVENTER WATTS LF909 FOR ICE MAKER
1 1/2" GAS FROM GAS METER FOR CONTINUATION SEE P-1.1
3/4" GAS LINE DOWN IN WALL TO EQUIPMENT
CONNECT 1 1/2"CW TO EXISTING 2"CW IN CEILING FIELD VERIFY EXACT LOCATION
1/2"CW DOWN IN WALL TO EQUIPMENT PROVIDE LINE SIZE ZONE OF REDUCED PRESSURE BACKFLOW
PREVENTER WATTS LF 909
EXTEND 3/4"CW AND 3/4"HW IN WALL TO FIXTURE AND EQUIPMENT
I
N
T
E
R
I
O
R
D
E
S
I
G
N
P-2
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
GA
S
H
O
T
A
N
D
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
CO
L
D
W
A
T
E
R
F
L
O
O
R
P
L
A
N
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
1
AB
2
3
21A
PATIO
SEATING AREA
(N)F.S.
(N)F.S.
(N)F.S.
(N)F.S.
(N)F.S.
(N)F.S.
3'-0"
49VL5GLG
CAKE STORAGE REFRIGERATOR 1
35600.0020BUNN1
CONVECTION OVEN 1
TUC-60TRUE1UNDERCOUNTER REFRIGERATOR 60" (TR)
CAKE PREP FRIDGE 48"2
UD-0310A1MANITOWICUNDERCOUNTER ICE MACHINE
COFFEE BREWER BUNN 53200.01011
TGM-22RV(B)-N6TURBO AIR
UNDERCOUNTER REFRIGERATOR 60"TURBO AIR JUR-60S-N6
GRINDER
DISPLAY CASE REFRIGERATED 60"1 TCGB-60UF-B-N
DECK OVEN (3 DECK)1 PARIS CROISSANT SD-3
4TV
2POS TOAST TOAST FLEX
1STAINLESS STEEL WORK TABLE 48"WT-EB3048
1STAINLESS STEEL WORK TABLE 36"
5' CUTTING BOARD W/L CLIP 1 CUTTING BOARD
1DROP IN HAND SINK
PREP. SINK 1 1B184-1D18R
3 COMPARTMENT SINK 1 60053242418G
HS-1317
TURBO AIR
NITRON COLD DRAFT SCHOLL COFFEE MACHINE 1 BUNN WRDG-51600.0020
1
2
3
5
6
7
8
10
11
12
13
14
15
16
17
18A
19
20
20A
21
22
23
24
25A
26
27
28
29
30
31
33
34
35
35A
36
37
38
39
40
41
42
43
1 PARIS CROISSANTDECK OVEN STAND
BREAD RACK (TALL)1 PARIS CROISSANT
CONVECTION OVEN (2 DECK)1 MOFFAT TURBOFAN
1 MOFF-E35D6-26/2CCONVECTION OVEN STAND MOFFAT TURBOFAN
3 TDC-30-2RNEW DOUGH CONDITIONER TURBO AIR
GRAB AND GO BEVERAGE 1 TURBO AIR TOM-50-B-N
1 TCGB-48UF-B-NTURBO AIRDISPLAY CASE REFRIGERATED 48"
SANDWICH PREPARATION REFRIGERATOR 1 MST-72-NTURBO AIR
1
THERMAL DISPENSER BUNN 42700.02002
BLENDER, BAR BLENDTEC S885C2901-B1GB1D2
DONUT FRYER
CAKE MIXER KSM8990WH
MICROWAVE OVEN (UNDERCOUNTER)NE-1025F
BREAD SLICER
ESPRESSO MACHINE
2PITCHER RINSER BLENDTEC RAPID RINSER
EMPLOYEE LOCKER 2
HAND SINK JOHN BOOS PBHS-W-1410-P-SSLR2
44
16"x20"x12"CHEMICAL SHELVE & MOP RACK
27.9"X22"X23.6"
13.3"X14.6"X16.5"120V, 500W, 60HZ
20.25"X16.5"X12"NSF
NSF
60 3/8"x30 1/8"x29 3/4"UL, NSF
NSF, ETL8.6"X9"X17.3"120V/220V-, 3.8HP
208V-, 30APROVIDE WATER FILTER SYSTEMPROVIDE APPROVED BACKFLOW PREVENTER FLOOR SINKINDIRECT
59"X27 1/2"X28 3/4"ETL 2.5" CASTER
72 5/8"X30"X37"UL, NSF 5" CASTER 115V-, 5.7AMP, 2/5HP
120V-, 13.5AMP
2.5" CASTER 115V, 5.1A 1/5HP
13"X17 1/2"X6 3/8"NSF 1/2"1/2"DIRECT
112"X29.5"X43.75"NSF
1/2"1/2"DIRECT
6" LEG 1/2"1/2"
PROVIDE APPROVED BACKFLOW PREVENTER
ETL
48 1/2"X34 1/4"X50 1/8"NSF 115V- 7.5A, 1/3HP4" CASTER
28 3/4"X27 5/8"X79 7/8"115V, 2.2A 1/5HPETL4" CASTER
23.9"X26.8"X34.6"120V-, 7.3AMP
14"X10"X5"NSF 1/2"1/2"DIRECT
18"X18"X14"NSF 6" LEG PROVIDE APPROVED BACKFLOW PREVENTER
FOLLOWING C.D INDIRECT FLOOR SINK1/2"1/2"
DIRECTW/ 18" DRAIN BD.
FOLLOWING C.D.
NSF
1
1
3
1
KTCHNNAID
PANASONIC
TURBO CHEF ECO
SPE-203-161825
MOFF-E35D6-26/2
THE ECO
65"x42"x21"5" CASTER 220V, 3PH, (3) 40AMPINDIRECTFLOOR SINKUL, NSF PROVIDE APPROVED BACKFLOW PREVENTER
1
1
JAC
EVERSYS
PICOMATIC
E4
MOP SINK45
46B
46C
WALL MOUNT SHELF 36"1836NK3-METROSEAL
WALL MOUNT SHELF 36"1436NK3-METROSEAL
5
3
METRO SUPER ERECTA
METRO SUPER ERECTA
EAGLE F1916-12 & 312690
EL-5DR
KROWNE
JOHN BOOS
REGENCY
1
54
55
STANDING SHELF (CHROME) 18" x 36"
STANDING SHELF (CHROME) 18" x 48"
70
71
STANDING SHELF (GREEN) 18" x 48"
STANDING SHELF (GREEN) 18" x 60"
2WALL MOUNT SHELF 24"METRO SUPER ERECTA 1824NK3-METROSEAL
86
86A
87
89
STAINLESS STEEL WALL-MOUNTED SHELF 6" x 36"
STAINLESS STEEL WALL-MOUNTED SHELF 6" x 60"
1
1
12X721
90
91
91A
91B
91C
WALL MOUNT SHELF 48" 1848NK3-METROSEAL
WALL MOUNT SHELF 72" 18X72
WALL MOUNT SHELF 72"
1
2
METRO SUPER ERECTA
1
2
14X72
12X72
STAINLESS STEEL WALL-MOUNTED SHELF 6" x 48"1
7
4
5
4
WALL MOUNT SHELF 72"
WALL MOUNT SHELF 72"
NSF 4" CASTER26"X20 1/4"X68 5/8"
50 7/8"X28"X78 1/2"NSF 4" CASTER 115V- 15.5A, 3/4HP
30"X28 1/2"X44 1/2"UL, NSF 6" LEG 115V- 10APROVIDE APPROVED BACKFLOW PREVENTER INDIRECT FLOOR SINK
WHOLE CAKE SHOWCASE, PB LED LIGHT
SHORT CAKE SHOWCASE, PB LED LIGHT
BACK LINE (FAN ON FRONT)
KITCHEN (FAN ON BACK)
PROVIDE WATER FILTER SYSTEM
5-TIER, 12"W x 20"D x 77"H
FOLLOWING C.D.
FOLLOWING C.D.
FOLLOWING C.D.
TUC-48-HC UL48 3/8"X30 1/8"X29 3/4"TRUE 115V-, 3AMP, 1/3HP5" CASTER
35 7/8"W x 77 1/2"H x 36 7/8"D
NSF, ETL35 7/8"W x 77 1/2"H x 36 7/8"D
220-240V, 60Hz, 12.5kW
208V, 60Hz, 11.2kWNSF, ETL
220-240V, 60Hz, 12.5kW
208V, 60Hz, 11.2kW
31 1/2" x 48 3/4" x 77 7/8"ETL 115/60/1
601/2" X 34 1/4" X 50 1/8"NSF 115V- 7.5A, 1/3HP
20.2"W x 22.3"D x 35"H UL, NSF 120V/240V, 60 HERTZ
10"W x 28.4"D x 34"H NSF, ETL 120V, 60 HERTZ
120V, 60 HERTZ9.4"W x 18.6"D x 29.1"H
NSF, ETL
UL, ETL
NSF9.3"W x 13"D x 20.7"H
UL16.1"W x 23.5"D x 21.5"H 208/240 VAC, 60Hz, 20AMP
42.425"W x 3.531"D x 23.929"H
High Mode: 10” x 14” x 8.6
Low Mode: 6.5” x 14” x 8.6”24 Volt
NSF8.8"W x20.5"D x 7.5" H
GSW USA
GSW USA 30"W x 48"L x 35" H
30"W x 36"L x 35" HGSW USA WT-EB3036
NSF
ETL
NSF
ETL
12"W x 20"D x 77" H
18"W x 36"L
14"W x 36"L
NSF
NSF
18"W x 24"L
18"W x 48"L
NSF
NSF
METRO 4'-0"X1'-6"X6'-0"1848 BR 5 TIES - 18" DEPTHNSF6" LEG
1836 BR 3'-0"X1'-6"X6'-0"5 TIES - 18" DEPTH6" LEGNSFMETRO
BLUEAIR 48"X12"WS1248 NSF
BLUEAIR 36"X12"WS1236 NSF
BLUEAIR 60"X12"WS1260 NSF
METRO SUPER ERECTA
METRO SUPER ERECTA
METRO SUPER ERECTA
METRO SUPER ERECTA
METRO SUPER ERECTA
PITCO 15-5/8"X35"X52"120V, 3PH, 0.5AMPETL6" LEG 44,000BTUBNB-SG14
REGENCY 4'-0"X1'-6"X6'-0"NSF 5 TIES - 18" DEPTH6" LEG
REGENCY 5'-0"X1'-6"X6'-0"NSF 5 TIES - 18" DEPTH6" LEG
DUMP SINK 1 NSF -DIRECT
1DIPPER WELL KROWNE 16-149 NSF7 3/16 X 6 3/16 NSFNSF INDIRECT
(FLOOR MOUNTED)
PROVIDE APPROVED BACKFLOW PREVENTER
PROVIDE APPROVED BACKFLOW PREVENTER
PROVIDE APPROVED BACKFLOW PREVENTER
AIR CURTAIN MARS ETL 115V, 9A 1HPAIR VELOCITY MIN.1600FPM (PROVIDED
2389FPM),DOOR SWITCH ACTIVATED TYPE36 "X16"X14"NH-236-1U-TS192
(E)FIXED WINDOW
TO REMAIN (E)FIXED WINDOW
TO REMAIN
(E
)
F
I
X
E
D
W
I
N
D
O
W
TO
R
E
M
A
I
N
01KITCHEN EQUIPMENT PLAN
Scale: 1/4" = 1'-0"
WATER HEATER 1 SEE PLUMBING DRAWING
INDIRECT
STANDING SHELF (GREEN) 18" x 36"2 REGENCY 3'-0"X1'-6"X6'-0"NSF 5 TIES - 18" DEPTH6" LEG
SELF CLOSING
HARDWARE
HS-1317 13"X17 1/2"X6 3/8"KROWNE FOLLOWING C.D.
I
N
T
E
R
I
O
R
D
E
S
I
G
N
P-3
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
SO
I
L
,
W
A
S
T
E
A
N
D
V
E
N
T
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
F
L
O
O
R
P
L
A
N
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
I
N
T
E
R
I
O
R
D
E
S
I
G
N
P-4
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
KI
T
C
H
E
N
E
Q
U
I
P
M
E
N
T
P
L
A
N
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
1NO SCALETRAP PRIMER DETAIL
2NO SCALETHREE COMPARTMENT SINK DETAIL
3NO SCALEVENT THRU ROOF DETAIL
5NO SCALEINDIRECT DRAIN DETAIL
6NO SCALEPIPE HANGER DETAIL
7NO SCALEWALL CLEANOUT DETAIL11NO SCALEAREA SEPARATION PENETRATION PIPE
TAPPED P-TRAP ADAPTER,
PPP INC. OR EQUAL
1/2" COPPER TUBING. ROUTE (THRU
PARTITION FOR RESTROOM AND
EXPOSED TIGHT TO WALL IN
MAINTENANCE) BELOW FLOOR TO
P-TRAPS SEE PLAN.
DISTRIBUTION UNIT
C.W. SUPPLY
3/4"x1/2" TEE.
BALL VALVE
TRAP PRIMER VALVE "TP" WITH
INTEGRAL BACKFLOW PREVENTER AND
VACUUM BREAKER PORT.
DISTRIBUTION UNIT TO BE MOUNTED
(ABOVE CEILING IN MAINTENANCE
ROOM AND TOILET ROOM)
FINISH FLOOR
WASTE LINE
P-TRAP
PIPE MAY EXTEND AS WASTE
OR VENT.
PROVIDE CLEANOUT TEE WITH
SCREWED COUNTER- SUNK ABS
PLASTIC PLUG: TAPERED-THREAD WITH
TFE JOINT COMPOUND.
WHERE CLEANOUT TEE IS CONCEALED
IN A CHASE OR PARTITION, PROVIDE A
ROUND 18 GAUGE STAINLESS STEEL
COVER WITH BEVELED EDGES AND
FLATHEAD MACHINE SCREW.
COLUMN OR PARTITION
AS SHOWN ON FLOOR
PLAN.
CLEANOUT FACE SHALL
BE WITHIN 4" OF WALL
SURFACE. PROVIDE
EXTENSION IF REQUIRED.
CONCRETE
FLOOR SLAB.
RISER LENGTH
AS REQUIRED
HUB AT FLOOR
LONG SWEEP AT END OF LINE OR
COMBINATION WYE AND EIGHTH BEND
IN RUN OF LINE.
PROVIDE WCO WHERE SHOWN ON PLAN, AND ON SANITARY WASTE BRANCHES NOT SERVED WITH A FLOOR
CLEANOUT: LOCATE ABOVE FIXTURE FLOOD RIM WITHIN 4' OF FLOOR. CONSULT LOCAL CODES FOR OTHER WCO
REQUIREMENTS.
DIRECTION
OF FLOW
TOP BEAM C-CLAMP
IF STEEL BAR JOIST
ROOF DECK
PROVIDE COPPER OR
NON-METALLIC COATING
WHERE HANGERS
CONTACT
BARE COPPER PIPE
ALL-THREAD ROD.
LENGTH
AS REQUIRED FOR PIPE
SLOPE
CLEVIS HANGER FOR
PIPE OVER FOUR INCH
PROVIDE GALVANIZED STEEL SADDLE
FOR ALL INSULATED PIPE LARGER
THAN 3/4". VERIFY INSULATION
THICKNESS WHEN SIZING HANGERS.
DO NOT HANG PIPE LARGER
THAN 3" FROM BOTTOM OF
JOISTS.
ADJUSTABLE BAND
HANGER FOR PIPING
FOUR INCH OR LESS
FLOOR
1"DX COIL
CO
CO
NO INSULATION ON PIPE RISER
SEE FLOOR PLAN FOR RECEPTACLE LOCATION.
WALK-IN COOLER OR FREEZER BOX
INSTALL PIPE HIGH AS POSSIBLE, ANCHORED TO WALL OF BOX WITH SUPPORTS AT MAXIMUM SIX FOOT CENTERS. USE
TYPE "M" HARD COPPER TUBE AND FITTINGS WITH LEAD-FREE SOLDER JOINTS. SLOPE HORIZONTAL PIPE AT MINIMUM
TWO PERCENT. REFER TO LOCAL CODE FOR INDIRECT DRAIN REQUIREMENTS.
PROVIDE A COMPLETE FREEZE PROTECTION SYSTEM FOR CONDENSATE PIPING IN FREEZER BOX EQUIVALENT TO
RAYCHEM/TYCO #5XL-1-CR @ 120V, WITH AN OUTPUT OF 5 WATTS PER FOOT AND 40°F START-UP TEMPERATURE.
PROVIDE TRAP AT BOTTOM
OF RISER AND DISCHARGE
INTO FLOOR DRAIN OR
FLOOR SINK WITH AIR GAP
OF TWO PIPE DIAMETERS
SILICONE SEAL AROUND
PIPE PENETRATION
PROVIDE 1" ELASTOMERIC INSULATION
OVER FREEZE PROTECTION ON
CONDENSATE LINE
PROVIDE CLEANOUT IN
TURNS AND ENDS OF PIPE
MAKE CONNECTION
TO COIL AS REQUIRED
REFRIGERANT LINES UP TO
REMOTE CONDENSING UNIT
ON ROOF.
PROVIDE CLEANOUTS IN
TURNS/ENDS OF PIPE.
USE DWV FITTINGS IF
SIZE IS LARGER THAN 1"
SLOPE PIPE AS MUCH
AS POSSIBLE TOWARD
DISCHARGE
MAKE CONNECTION TO
EQUIPMENT AS REQUIRED
DISCHARGE INTO CENTER HOLE
OF GRATE OF WASTE
RECEPTACLE WITH AIR GAP
SUFFICIENT TO REMOVE GRATE
AND STRAINER. MINIMUM GAP =
TWO PIPE DIAMETERS
MAKE PIPE MINIMUM ONE SIZE
LARGER THAN EQUIPMENT
CONNECTION, MINIMUM 3/4". USE "M"
OR "L" HARD COPPER UP TO 1" AND
TYPE DWV FOR LARGER
ROUTE PIPE INCONSPICUOUSLY AND UNOBTRUSIVELY. HANG PIPE AS REQUIRED. DO NOT INSULATE
INDIRECT DRAIN PIPE WHEN INSTALLED EXPOSED IN FOOD SERVICE FACILITY. REFER TO LOCAL CODES FOR
FURTHER INFORMATION.
VERIFY WITH LOCAL
CODES IF/WHEN TRAP
AND/OR VENT ARE
REQUIRED FOR THE
LENGTH OF DRAIN PIPE
INSTALLED
FCU
PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN HERE. DO NOT INSTALL HANGER INSIDE
INSULATION OR OTHERWISE PENETRATE VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER EXCEPT IN CHASES.
TRAPEZE HANGERS MAY BE USED FOR MULTIPLE PARALLEL PIPES. HANGER SPACING FOR PIPE SIZE: COPPER: 4"=12'
3"=11' 2-1/2"=10' 2"=9' 1-1/2"=8' 1-1/4"=7' 1"=6' 3/4"=6' 1/2"=5'. CAST IRON: 10' AND ONE NEAR ALL JOINTS. STEEL: 4"=14' 3"=12'
2-1/2"=11' 2"=10' 1-1/2"=9' 1"=7' 3/4"=6' 1/2"=5'. LOCATE HANGERS AS CLOSE AS POSSIBLE TO TURNS AND TEES OF PIPE.
PROVIDE SUPPLEMENTARY STEEL STRUTS BETWEEN JOISTS IF REQUIRED.LOCATE HANGERS TO TAKE LOAD OFF OF
EQUIPMENT CONNECTIONS. DUE TO CHANGES IN WATER VELOCITY. ANCHOR WATER PIPE AGAINST SWAYING PROVIDE
SEISMIC BRACING IF/AS REQUIRED BY LOCAL AUTHORITIES. CHAINS OR PERFORATED STRAP IRON OR STEEL IS NOT
ACCEPTABLE. REFER TO CODES FOR FURTHER INFORMATION. CONFORM TO MSS SP-58.
1" CONDENSATE DRAIN WITH
TRAP BY CONTRACTOR
A=FAN STATIC PRESSURE ("W.C.)
B= A/2 + 1"
A
B
MIN. 1% SLOPE
4NO SCALECONDENSATE DETAIL8NO SCALECOOLER / FREEZER CONDENSATE DRAIN DETAIL
FOR VENT THRU ROOF
PROVIDE VENT CAP
ROOF PENETRATION
(STL. PIPE, TUBE OR
SIM. ITEM)
CAULK WITH
ELASTOMERIC
SEALANT
DRAW BAND WITH
NEOPRENE GASKET
WATERTIGHT
UMBRELLA
ROOFING
FLANGE SET IN
MASTIC OVER ROOFING-
PRIME FLANGE BEFORE
STRIPPING
FINISHED ROOF DECK
REFER TO ARCHITECT
AND STRUCTURAL DWGS.
3"
2"V
GENERAL NOTE:
1.3-COMPARTMENT SINK SHALL BE CONNECTED DIRECTLY TO THE DRAINAGE SYSTEM , UNLESS
DIRECTED OTHERWISE BY COUNTY HEALTH DEPARTMENT. A FLOOR DRAIN SHALL BE PROVIDED
ADJACENT TO THE FIXTURE, AND THE FIXTURE SHALL BE CONNECTED ON THE SEWER SIDE OF
THE FLOOR DRAIN TRAP; NO OTHER DRAINAGE LINE SHALL BE CONNECTED BETWEEN THE
FLOOR DRAIN WASTE CONNECTION AND THE FIXTURE DRAIN. THE FIXTURE AND FLOOR DRAIN
SHALL BE TRAPPED AND VENTED IN ACCORDANCE WITH CODE 704.3
ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD
CONDITIONS OR MEET LOCAL CODE REQUIREMENTS. DWV
COPPER PIPE, FITTINGS AND CONNECTORS ALL AROUND SINK.
ROUTE COMBINED GREASE DRAIN LINE TO WALL. ROUTE
VENT UP, AND GREASE DOWN AS SHOWN ON PLANS.
FLOOR
SEE NOTE #1
PIPE
PIPE COVERING
PUTTY: MINIMUM
THICKNESS OF FILL MATERIAL
APPLIED WITHIN THE ANNULUS ON
TOP SURFACE OF FLOOR.
PACKING MATERIAL:
MINIMUM 4PCF MINERAL
WOOL BATT INSULATION
U.L. SYSTEM No. C-AJ-5054
PENETRATING ITEM:
COPPER TUBING 1-1/2"
DIA (OR SMALLER)
TYPE ''L'' OR ''K''
PIPE COVERING
PIPE WALL ASSEMBLY
(WOOD OR STEEL
CHANNEL STUDS
WITH GYPSUM
WALLBOARD)
WALL ASSEMBLY
(WOOD OR STEEL
CHANNEL STUDS
WITH GYPSUM
WALLBOARD)
PENETRATING ITEM: COPPER
TUBING 6 INCH DIA. OR
SMALLER TYPE ''L'' OR ''K''
PIPE
CAULK FILL MATERIAL
INSTALLED TO COMPLETELY
FILL ANNULAR SPACE
BETWEEN PIPE AND GYPSUM
WALL BOARD AND WITH A
MINIMUM 1/4INCH DIA. BEAD OF
CAULK APPLIED TO PERIMETER
OF PIPE AT ITS EGRESS FROM
THE WALL.
U.L. SYSTEM No. W-L-1001
5/16''DIA x 2''LG. STEEL WALL
ANCHOR EQUALLY SPACED
(TOTAL OF 6)
PENETRATING ITEM: COPPER
TUBING 6 INCH DIA. OR
SMALLER TYPE ''L'' OR ''K''
PUTTY: MINIMUM 5-INCH
OF FILL MATERIAL
APPLIED WITHIN THE
ANNULUS ON BOTH
SURFACES OF THE WALL
GALV. SHEET METAL
SLEEVE W/ TABS TO
RETAIN PUTTY
TRIM RING
U.L. SYSTEM No. W-L-5001
PENETRATIONS OF PIPES, CONDUITS, ETC., IN WALLS,
FLOORS OR CEILING ASSEMBLIES REQUIRING
PROTECTED OPENINGS SHALL BE FIRE STOPPED. FIRE
STOP MATERIAL SHALL BE A TESTED ASSEMBLY AS
PRESCRIBED IN U.B.C. STANDARD 7-5 AND AS
APPROVED BT THE OSHPD FIRE MARSHALL (C.B.C. 714)
CONCRETE FLOOR
CEILING
12NO SCALEINSTANTANEOUS GAS WATER HEATERS PIPING SCHEMATIC
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
I
N
T
E
R
I
O
R
D
E
S
I
G
N
P-5
ah
k
|
a
r
c
h
i
t
e
c
t
u
r
e
ar
c
h
i
t
e
c
t
u
r
e
/
p
l
a
n
n
i
n
g
/
i
n
t
e
r
i
o
r
13
0
0
5
m
e
s
a
v
e
r
d
e
w
a
y
,
s
y
l
m
a
r
,
c
a
l
i
f
o
r
n
i
a
9
1
3
4
2
em
a
i
l
:
co
n
t
a
c
t
@
a
h
k
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
KI
T
C
H
E
N
E
Q
U
I
P
M
E
N
T
P
L
A
N
DE
S
I
G
N
EL
M
PA
R
I
S
B
A
G
U
E
T
T
E
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
7
L
A
S
T
U
N
A
S
D
R
.
S
U
I
T
E
"
A
"
A
R
C
A
D
I
A
,
C
A
9
1
0
0
7
E-mail: pc.philchon@gmail.com
5415 Burning Tree Dr
TEL : 213.453.7188
/D&DxDGD)OLQWULGJH&$
PA
R
I
S
B
A
G
U
E
T
T
E
E-1
E-mail: pc.philchon@gmail.com
5415 Burning Tree Dr
TEL : 213.453.7188
/D&DxDGD)OLQWULGJH&$
PA
R
I
S
B
A
G
U
E
T
T
E
E-2
E-mail: pc.philchon@gmail.com
5415 Burning Tree Dr
TEL : 213.453.7188
/D&DxDGD)OLQWULGJH&$
PA
R
I
S
B
A
G
U
E
T
T
E
E-3
E-mail: pc.philchon@gmail.com
5415 Burning Tree Dr
TEL : 213.453.7188
/D&DxDGD)OLQWULGJH&$
PA
R
I
S
B
A
G
U
E
T
T
E
E-4
E-mail: pc.philchon@gmail.com
5415 Burning Tree Dr
TEL : 213.453.7188
La Cañada Flintridge, CA 91011
PA
R
I
S
B
A
G
U
E
T
T
E
E-5
Luminaire Schedule
Symbol Qty Label Arrangement Total Lamp Lumens LLF Description
18 EX SINGLE N.A.0.70 EMERGENCY UNIT
Calculation Summary
Label CalcType Units Avg Max Min Avg/Min Max/Min
PARIS BAGUETTE ARCADIA EM_Floor Illuminance Fc 2.03 4.7 0.3 6.77 15.67
0.9 2.0 1.7 1.2 1.1 0.9 0.6
1.8 3.4 2.3 2.3 2.9 2.5 1.6
1.7 3.6 2.8 2.8 2.9 2.9 2.2
1.5 2.6 2.5 2.6 3.1 2.2 1.5
1.6 2.5 1.8 2.4 2.7 1.4
1.1
2.4 3.5 1.4 0.6 0.4 0.5
2.7 2.1 1.0 0.9 1.0 0.9 0.9
4.6 2.6 1.4 2.9 2.6 1.6 1.6
1.4 3.0 2.7 1.5 2.6
3.2
0.4 2.2 2.7
2.2 3.2 4.1 2.0
2.1 1.3 1.6
0.3 0.3
1.8 0.6
3.1 4.7 2.1
2.1 2.8 1.3
E-mail: pc.philchon@gmail.com
5415 Burning Tree Dr
TEL : 213.453.7188
/D&DxDGD)OLQWULGJH&$
PA
R
I
S
B
A
G
U
E
T
T
E
PH-1