Loading...
HomeMy WebLinkAbout7 Las Tunas Dr A - 2022 - TI Paris BaguetteS100 01A L L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F F T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E H W A N G S T R U C T U R A L E N G I N E E R S I N C . C O P Y R I G H T A L L R I G H T S R E S E R V E D . DRAWN BY LAST REVISED DATE PROJECT NO. SHEET TITLE DRAWING NO. SHEET:OF: - Engineer Seal: Project : 03 - - 02/03/2023 R E R LR S G A E F G E L N O G A WEHDOETSAHN A J T U T E T I UC L I F R O S T U F R No. 5592 Exp.06-30-23 CA IOSSENPRO N N I IA E R N 3501 Ocean View Blvd. Glendale, CA 91208 j u n o @ h w a n g s e .c o m T e l . 2 1 3 ) 2 6 8 -0 9 3 5 StructuralEngineers In c . Revisions DESCRIPTIONNO. GENERAL NOTES & INFO. ABBREVIATIONS &AND@AT Ø DIAMETERA.B.ANCHOR BOLT A.C.I.AMERICAN CONCRETE INSTITUTEA.I.S.C.AMERICAN INSTITUTE OF STEEL CONSTRUCTION ALT.ALTERNATEASSN.ASSOCIATIONAPPROX.APPROXIMATELY ARCH.ARCHITECTURALA.S.T.M.AMERICAN STANDARD FOR TESTING AND MATERIALS A.W.S.AMERICAN WELDING SOCIETY (B), BOT.BOTTOM BET.BETWEENBFBRACED FRAME BLDG.BUILDING BLK.BLOCKBLKGBLOCKING BM.BEAMB.N.BOUNDARY NAILING B.S.BOTH SIDES C CHANNEL OF CAMBER CANT CANTILEVERCAT.CATALOG C.B.C.CALIFORNIA BUILDINGCODE C.I.P.CAST-IN-PLACE CONCRETE C.J.CONSTRUCTION JOINT ORCEILING JOINT , CL.CENTERLINE CLG.CEILING CLR.CLEARC.M.U.CONCRETE MASONRY UNIT CO.COMPANYCOL.COLUMN CONC.CONCRETE CONST.CONSTRUCTIONCONT.CONTINUOUS CRIP.CRIPPLECTR.CENTER CU.FT.CUBIC FEETCU.IN.CUBIC INCH CU.YD.CUBIC YARD d b BAR DIAMETER DBL.DOUBLEDET.DETAILDIA.DIAMETER DIAG.DIAGONALDIM.DIMENSION D.L.DEAD LOADDN.DOWN DO.DITTO DWG.(S)DRAWING(S) (E)EXISTINGEA.EACH EE.EACH END E.A.EACH FACEE.J.EXPANSION JOINT EL.ELEVATIONELEV.ELEVATOR EMBED.EMBEDMENTE.N. EDGE NAILING ENGR.ENGINEER EMGRG.ENGINEERINGEQ.EQUAL EQUIP.EQUIPMENTE.S.EACH SIDE ETC ET CETERAE.W.EACH WAY E-W EAST-WEST EXP.EXPANSIONEXT.EXTERIOR F.D.FLOOR DRAIN FDN.FOUNDATION F.F.FINISH FLOOR F.G.FINISH GRADE FIN.FINISHF.J.FLOOR JOIST F.L.G.FLANGEFL.FLOOR F.O.FACE OFF.O.C.FACE OF CONCRETE F.O.M.FACE OF MASONRY F.O.S.FACE OF STUDF.P.FULL PENETRATION F.T.FEET OR FOOTFTG.FOOTING GA.GAUGEGALV.GALVANIZED G.B.GRADE BEAMGLBGLU-LAM BEAM GYP. BD.GYPSUM BOARD (H)HIGH HDR HEADERHGRHANGER HORIZ.HORIZONTALH.S.B.HIGH STRENGTH BOLT HT.HEIGHT I.C..O.INTERNATIONAL CONFERENCE OFBUILDING OFFICIALS I.D.INSIDE DIAMETERI.F. INSIDE FACE IN.INCH(ES)INFO.INFORMATION INT.INTERIOR JT.JOINT JST.JOIST K.KIP (1,000 LBS) K/FT, K/'KIPS PER FOOTKSIKIPS PER SQUARE INCH (L)LOW LG.LONG LIN.LINEARL.F.LIVE LOAD LONGIT.LONGITUDINALL.S.LAG SCREW LT.WT.LIGHT WEIGHT M.B.MACHINE BOLT M.D.MID-DEPTHMATL.MATERIAL MAX.MAXIMUM MECH.MECHANICALMEMB.MEMBRANE MFR.MANUFACTURERMIN.MINIMUMMISC.MISCELLANEOUS MTL.METAL (N)NEW N.A.NEUTRAL AXISNO., #NUMBER N-S NORTH-SOUTHN.T.S.NOT TO SCALE O.C., O/C ON CENTERO.D.OUTSIDE DIAMETER O.F.OUTSIDE FACEOPNG.OPENING ORIG.ORIGINAL PL.PLATE OF PROPERTY LINE PLYWD.PLYWOODP.S.F., psf POUNDS PER SQUARE FOOT P.S.I., psi POUNDS PER SQUARE INCHP.T.POST-TENSIONING R.RADIUSR.D.ROOF DRAIN REF.REFERENCEREINF.REINFORCE(D) / REINFORCING REQD.REQUIREDR.R.ROOF RAFTER S.A.D.SEE ARCHITECTURAL DRAWINGSSCHED.SCHEDULE SEC.SECTIONSHT.SHEET SIM.SIMILAR S.J.SLAB JOINT S.O.G.SLAB-ON-GRADE SPESC.SPECIFICATIONSSQ.SQUARE STAG.SRAGGER(ED)STD.STANDARD STIFF STIFFENER ST'L STEEL STR.STRAIGHT SYM.SYMMETRICAL (T)TOPT & B TOP AND BOTTOM T & G TONGUE AND GROOVE THK THICKNESS T.J.TRUSS JOIST T.O.C.TOP OF CONCRETET.O.F.TOP OF FOOTING T.O.S.TOP OF SLAB(STEEL)TS STRUCTURAL TUBE TRANS.TRANSVERSE TYP.TYPICAL U.B.C.UNIFORM BUILDING CODEU.N.O.UNLESS NOTED OTHERWISE VERT.VERTICALVARI.VARIOUS W/WITH WD WOOD W/O WITHOUTW.J.WALL JOINT W.P.M.WATERPROOF MEMBRANEWT.WEIGHT W.W.F WELDED WIRE FABRIC SYMBOLS SHEET INDEX INFO. N 01 ICC REPORT # -ITW RAMSET POWER-ACTUATED FASTERNERS AND CEILING CLIP ASSEMBLIES ESR-1799 -HILTI SELF-DRILLING AND SELF-PIERCING SCREWS ESR-2196 -HILTI KWIK BOLT TZ CARBON AND STAINLESS STEEL ANCHORS ESR-1917 GRID LINES NORTH ARROW TOP OF FLOORELEVATION EARTH GRAVEL MATCHLINE SHEET NUMBER DETAIL NUMBER SHEET NUMBER SECTION NUMBER SHEET NUMBER ELEVATION NUMBER SHEET NAME PLAN NUMBER PLAN ELEVATION SECTION DETAIL EL ±0'-0" # / #-# # / #-# # # # # # # P. SHEET NO.SHEET TITLE 1.S100 GENERAL NOTES & INFO. 2.S200 1ST FLOOR WALLS & ROOF FRAMING PLAN 3.S300 DETAILS & SECTION 1.ALL WORK SHALL CONFORM TO THE CBC 2019. 2.THE FOLLOWING NOTES AND ALL OTHER TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS NOTED OTHERWISE. 3.STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. 4.FRAMING CONDITIONS NOT SPECIFICALLY SHOWN SHALL BE FRAMED SIMILAR TO THE DETAILS SHOWN FOR THE RESPECTIVE MATERIALS. 5.PROVIDE OPENINGS AND SUPPORTS FOR MECHANICALS EQUIPMENT, DUCTS, PIPING, VENTS AND ETC., AS REQUIRED. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR ADDITIONAL OPENINGS AND EQUIPMENT WHICH ARE NOT SHOWN ON STRUCTURAL DRAWINGS. ALL SUSPENDED EQUIPMENT TO BE PROVIDED WITH APPROVED ALL BRACING. 6.CONTRACTOR MUST CLARIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE COMMENCING WORK. ARCHITECT SHALL BE INFORMED AND NOTIFIED ANY TYPE OF DISCREPANCIES. 7.NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER THESE GENERAL NOTES. 8.DESIGN MATERIALS, EQUIPMENT, AND PRODUCTS OTHER THAN THOSE DESCRIBED BELOW OR INDICATED ON THE DRAWINGS MAY BE CONSIDERED FOR USE. PROVIDED PRIOR TO APPROVAL IS OBTAINED FROM THE OWNER, ARCHITECT/ENGINEER, AND THE APPLICABLE GOVERNING CODE AUTHORITY. 9.CONTINUOUS INSPECTION BY A CITY LICENSED DEPUTY INSPECTOR IS REQUIRED FOR ALL STRUCTURAL CONNECTIONS, FOOTINGS, GRADE BEAMS, AND RETAINING WALLS DURING INSTALLATION. 10.DESIGN CRITERIA EARTHQUAKE DESIGN DATA SEISMIC IMPORTANCE FACTOR (I) : 1.0 RISK CATEGORY : II MAPPED SPECTRAL RESPONSE ACCELERATIONS Ss : 1.882g S1 : 0.631g SITE CLASS : D SPECTRAL RESPONSE COEFFICIENTS SDS : 1.254g SEISMIC DESIGN CATEGORY : D GENERAL NOTES METAL STUDS AND ACCESSORIES -MEET OR EXCEED MIN. REQUIREMENTS OF FED. SPEC. QQ-S-698 AND FED. SPEC. QQ-S-775d, FOR THE ITEM AND USE IN-TENDED METAL STUDS: 1.AT INTERNAL METAL STUD PARTITIONS, UNLESS OTHERWISE SHOWN ON THE DRAWINGS, PROVIDE STANDARD PUNCHED STEEL STUDS OF THE GAGES SHOWN ON THE DRAWINGS, EITHER HOT-DIP GALVANIZED OR FACTORY PRE-PAINTED. 2.USE ONLY ONE TYPE THROUGHOUT THE WORK, UNLESS OTHERWISE SHOWN ON THE DRAWINGS OR SPECIFICALLY APPROVED IN ADVANCE BY THE ARCHITECT OR ENGINEER ACCESSORIES: PROVIDE ALL ACCESSORIES INCLUDING, BUT NOT NECESSARILY LIMITED TO, TRACKS, CLIPS, ANCHORS, FASTENING DEVICES, SOUND ATTENUATION PENCIL RODS AND RESILIENT CLIPS, AND OTHER ACCESSORIES REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, AND AS RECOMMENDED BY THE MANUFACTURER OF THE STEEL STUDS USED. ALL METAL STUDS AND SCREWS PROVIDED BY METAL SYSTEM. (I.C.B.O. #4943) 3.ALL SCREWS COMPLY TO ICBO. NER-211.PA R I S B A G U E T T E 17 L A S T U N A S D R . AR C A D I A , C A 9 1 0 0 7 WOOD FRAMES 1.ALL LUMBER TO BE STRESS GRADE, DOUGLAS FIR LARCH(DF), AS SHOWN BELOW PLANS PER NDS 2018 UNLESS OTHER WISE INDICATE ON A. JOISTS AND RAFTER : DF #2 GRADE B. 2"-4" BEAM : DF #1 GRADE : DF #2 GRADE FOR HEADER C. 5"x5" LARGER BEAM : DF #1 GRADE D. STUDS : DF #2 GRADE E. POST AND COLUMN : DF #1 GRADE 2.MOISTURE CONTENT IN USE WILL BE A MAXIMUM OF 19%. 3.DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS, UNLESS OTHERWISE NOTED, AND ALSO NAILED TOGETHER WITH 16d NAILS @9" O.C.. 4.UNLESS OTHERWISE NOTED ALL NAILING SHALL CONFORM TO THE NAILING SCHEDULE REQUIRED BY THE LOCAL DEPARTMENT OF THE BUILDING AND SAFETY. 5.UNLESS OTHERWISE INDICATED, RAFTERS AND JOIST SHALL BE SPLICED AT SUPPORTS WITH A MINIMUM OF 4" OF LAP AND 4-16d NAILS. 6.TOP PLATE OF ALL STUD WALLS SHALL BE 2 PIECES OF 2x4 PLATES. SPLICES TO LAP 4'-0" MINIMUM AND BE NAILED WITH 12-16d NAILS MINIMUM EACH SIDE OF JOINT. 7.PROVIDE SOLID 2x BLOCKING BETWEEN JOISTS AND RAFTERS AT ALL SUPPORTS. BLOCKING SHALL BE ONE PIECE AND THE FULL DEPTH OF THE JOIST OR RAFTER. 8.EACH SHEET OF PLYWOOD SHALL BE IDENTIFIED BY A REGISTERED STAMP OR BRAND OF THE DOUGLAS FIR PLYWOOD ASSOCIATION. 9.WOOD STRUCTURAL PANELS SHALL COMPLY WITH U.S. PRODUCT STANDARDS FOR ITS TYPE IN PS 1 OR PS 2 AND BE CLASSIFIED AS EXPOSURE 1. AS A MINIMUM ALL WOOD STRUCTURAL PANELS SHALL BE APA RATED SHEATHING UNLESS NOTED OTHERWISE ON PLANS AND DETAILS. 10.STRUCTURAL MEMBERS SHALL NOT BE CUT FOR PIPES, ETC. UNLESS SPECIFICALLY DETAILED. 11.SHEATHING AND SHEAR WALLS SHALL BE INSPECTED AND APPROVED PRIOR TO COVERING. 12.BORED HOLES SHALL NOT BE LOCATED AT THE SAME SECTION OF STUD AS A CUT OR NOTCH. 13.ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANEL EDGES. 14.ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. 15.BOLT HOLES IN WOOD SHALL BE 1/32" TO 1/16" LARGER THAN THE NOMINAL BOLT DIAMETER. ALL BOLTS SHALL HAVE STANDARD CUT WASHER UNDER HEAD AND NUT UNLESS OTHERWISE NOTED. 16.FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT TREATED WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. SCALE : 1/4"=1'-0" 1ST. FLOOR WALLS & ROOF FRAMING PLAN 01 S200 1ST. FLOOR WALLS & ROOF FRAMING PLAN 02A L L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F F T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E H W A N G S T R U C T U R A L E N G I N E E R S I N C . C O P Y R I G H T A L L R I G H T S R E S E R V E D . DRAWN BY LAST REVISED DATE PROJECT NO. SHEET TITLE DRAWING NO. SHEET:OF: - Engineer Seal: PA R I S B A G U E T T E Project : 03 - - 17 L A S T U N A S D R . AR C A D I A , C A 9 1 0 0 7 2023/03/02 R E R LR S G A E F G E L N O G A W E HDOETS AHN A J T U T E T I UC L I F R O S T U F R No. 5592 Exp.06-30-23 C A IOSSENPRO N N I IA E R N 3501 Ocean View Blvd. Gl en da l e, CA 91208 j u n o @ h w a n g s e .c o m T e l . 2 1 3 ) 2 6 8 -0 9 3 5 StructuralEngineers Inc. Revisions DESCRIPTIONNO. SHEET NOTES DESCRIPTION PLAN LEGEND SYMBOL 1.SEE SHEET S100 MATERIAL SPECIFICATIONS & ROOF FRAMING NOTES. INDICATES (E)TRUSSES @24" O.C. INDICATES KITCHEN HOOD. SEE DETAIL 1/S300 * EXISTING MEMBERS AND THEIR DIRECTIONS SHALL BE VERIFIED WITH THE STRUCTURAL PLAN BEFORE CONSTRUCTION. INDICATES BLOCKING. SEE DETAIL 2/S300 2" (N) (E)EQUI. (E ) 6 3 / 4 " x 2 8 1 / 2 " G L B R O O F B E A M (E)6 3/4"x18" GLB ROOF BEAM (E ) T R U S S E S @ 2 4 " O . C . DO . DO . (E ) T R U S S E S @ 2 4 " O . C . DO . (E)HDR. DO . DO . DO . DO . (E ) T R U S S E S @ 2 4 " O . C . DO . (E)5 1/8"x28 1/2" GLB ROOF BEAM (E ) 8 3 / 4 " x 3 0 " G L B R O O F B E A M DO . (E ) H D R . (E ) H D R . (E ) H D R . DO . DO . DO . DO . (E ) T R U S S E S @ 2 4 " O . C . DO . DO . DO . (E ) T R U S S E S @ 2 4 " O . C . DO . DO . DO . DO . (E ) T R U S S E S @ 2 4 " O . C . (N) EQUI. 2 S300 TYP. 1 S300 TYP. 3 S300 TYP. DO . DO . DO . DO . (E ) T R U S S E S @ 2 4 " O . C . DO . DO . DO . DO . (E ) T R U S S E S @ 2 4 " O . C . DO . DO . S300 03A L L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F F T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E H W A N G S T R U C T U R A L E N G I N E E R S I N C . C O P Y R I G H T A L L R I G H T S R E S E R V E D . DRAWN BY LAST REVISED DATE PROJECT NO. SHEET TITLE DRAWING NO. SHEET:OF: - Engineer Seal: PA R I S B A G U E T T E Project : 03 - - 17 L A S T U N A S D R . AR C A D I A , C A 9 1 0 0 7 02/03/2023 R E R LR S G A E F G E L N O G A WEHDOETSAHN A J T U T E T I UC L I F R O S T U F R No. 5592 Exp.06-30-23 CA IOSSENPRO N N I IA E R N 3501 Ocean View Blvd. Glendale, CA 91208 j u n o @ h w a n g s e .c o m T e l . 2 1 3 ) 2 6 8 -0 9 3 5 StructuralEngineers In c . Revisions DESCRIPTIONNO. DETAILS & SECTION 1SCALE : N.T.S. HOOD SECTION 10'-8" SEE ARCH. PLAN 5'- 2 " SE E A R C H . 350S137-43 KITCHEN HOOD UNISTRUTP1000 UNISTRUT P1000 UNISTRUTP1000 UNISTRUT P1000 KITCHEN HOOD L4x4x1/4" 350S137-43@4 PLACESSEE PLAN (E)WOOD BEAMSEE PLAN L4x4x1/4" W/ 1/2"Ø M.B.(4)-10d COMMON NAIL Wt=221 lbs 15'-8" MAX 2" MI N . 6" MA X . 2" MI N . L 1/2Ø ROD BEYONDSEE PLAN ROD STIFFENERHARDWARE (L=24"O.C. AT EACH ROD)TORQUE: SNUG TIGHT 2" MI N . 6" MA X . 2" MI N . L UNISTRUT P1000 1/2Ø RODBEYONDSEE PLAN 1/2Ø ROD 1/2Ø ROD L L L L L L UNISTRUTP1000 350S137-43 L4x4x1/4" W/ 1/2"Ø M.B. 350S137-43 VIEW "A" RIGID INSULATION(FIELD SUPPLIED) 14 " DUCT(FIELD SUPPLIED) HEAD OF BOLT TO BE ONINSIDE OF FLANGE(TYP. ALL CORNERS) 1/2"ØLAG SCREW 1"THK.POLYURETHANEFOAM16GA 3/8"Ø LAG SCREW W/2"MIN. PENETRATION @24"O.C. 2SCALE : N.T.S. ROOF EQUIPMENT PAD DETAIL (E)TRUSS JOISTSEE PLAN (E)WALL "A" SEE PLAN (E)WALL SEE PLAN 2x10 LEDGER PER PLAN BY OTHERSATTACH TO TOP CHORD WITH10dx3" @6"O.C. AND (2)-10dx3" WEB.LEDGER MUST BE MINIMUM LENGTHREQUIRED TO REACH 2 TRUSS PANELPOINTS. L4x4x1/4" W/ 1/2"Ø M.B. (E)TRUSS JOIST 2x10 LEDGER PER PLAN BY OTHERSATTACH TO TOP CHORD WITH10dx3" @6"O.C. AND (2)-10dx3" WEB.LEDGER MUST BE MINIMUM LENGTHREQUIRED TO REACH 2 TRUSS PANELPOINTS. 4x BLOCKING ANDHANGER BY OTHRES ALT. DETAIL 5'-0" 12"12" @3" O.C 3" MI N . 350S137-43 350S137-43 4x6 BLOCKING SIMPSON HANGER"BA" (TYP.) (E)WOOD TRUSS SEE PLAN EQUIPMENT SIMPSON A35 4x6 BLOCKING 4x8 #2@32"O.C. 15/32" PLYWOOD "CDX"W/8d @6/12 SIMPSON STRAPLSTA9 @16" O.C. 3/8"Ø LAG SCREWW/2"MIN. PENETRATION@24"O.C.4x8 #2 (5)-10d COMMON NAIL @4-SIDE SIMPSON HANGER"BA" (TYP.) (TYP.)(E)WOOD TRUSS SEE PLAN (E)WOOD TRUSS SEE PLAN (TYP.) (650LBS) SIMPSON HANGER "BA" (E)PLYWOODSHEATHING (E)TRUSS JOISTSEE PLAN SIMPSON STRAP"H8" @16" O.C. 3SCALE : N.T.S. ROOF EQUIPMENT PAD DETAIL 4x6 BLOCKING SIMPSON HANGER"BA" (TYP.) (E)WOOD TRUSSSEE PLAN SIMPSON HANGER"BA" (TYP.) (TYP.) (E)WOOD TRUSSSEE PLAN (E)WOOD TRUSSSEE PLAN 4x6 BLOCKING(TYP.) PRE-FAB. METAL CURBBY MANUFACTURER MAU MIN. (3)-1/4"Ø LAG SCREWW/3"MIN. PENETRATION (E)WD. BEAM SEE PLAN @ EACH SIDE I N T E R I O R D E S I G N M-1 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m LE G E N D A N D DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T GE N E R A L N O T E S 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 49VL5GLG CAKE STORAGE REFRIGERATOR 1 35600.0020BUNN1 CONVECTION OVEN 1 TUC-60TRUE1UNDERCOUNTER REFRIGERATOR 60" (TR) CAKE PREP FRIDGE 48"2 UD-0310A1MANITOWICUNDERCOUNTER ICE MACHINE COFFEE BREWER BUNN 53200.01011 TGM-22RV(B)-N6TURBO AIR UNDERCOUNTER REFRIGERATOR 60"TURBO AIR JUR-60S-N6 GRINDER DISPLAY CASE REFRIGERATED 60"1 TCGB-60UF-B-N DECK OVEN (3 DECK)1 PARIS CROISSANT SD-3 4TV 2POS TOAST TOAST FLEX 1STAINLESS STEEL WORK TABLE 48"WT-EB3048 1STAINLESS STEEL WORK TABLE 36" 5' CUTTING BOARD W/L CLIP 1 CUTTING BOARD 1DROP IN HAND SINK PREP. SINK 1 1B184-1D18R 3 COMPARTMENT SINK 1 E3S8-1620-14T18 HS-1317 TURBO AIR NITRON COLD DRAFT SCHOLL COFFEE MACHINE1 BUNN WRDG-51600.0020 H: HOT WATER C: COLD WATER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18A 19 20 20A 21 22 23 24 25A 26 27 28 29 30 31 33 34 35 35A 36 37 38 39 40 41 42 43 1 PARIS CROISSANTDECK OVEN STAND BREAD RACK (TALL)1 PARIS CROISSANT CONVECTION OVEN (2 DECK)1 MOFFAT TURBOFAN 1 MOFF-E35D6-26/2CCONVECTION OVEN STAND MOFFAT TURBOFAN 3 TDC-30-2RNEW DOUGH CONDITIONER TURBO AIR GRAB AND GO BEVERAGE 1 TURBO AIR TOM-50-B-N 1 TCGB-48UF-B-NTURBO AIRDISPLAY CASE REFRIGERATED 48" SANDWICH PREPARATION REFRIGERATOR 1 MST-72-NTURBO AIR 1 THERMAL DISPENSER BUNN 42700.02002 BLENDER, BAR BLENDTEC S885C2901-B1GB1D2 DONUT FRYER CAKE MIXER KSM8990WH MICROWAVE OVEN NE-1025F BREAD SLICER ESPRESSO MACHINE 1PITCHER RINSER BLENDTEC RAPID RINSER EMPLOYEE LOCKER 2 HAND SINK JOHN BOOS PBHS-W-1410-P-SSLR2 44 16"x20"x12"CHEMICAL SHELVE & MOP RACK 27.9"X22"X23.6" 13.3"X14.6"X16.5"120V, 500W, 60HZ 20.25"X16.5"X12"NSF NSF 60 3/8"x30 1/8"x29 3/4"UL, NSF NSF, ETL8.6"X9"X17.3"120V/220V-, 3.8HP 208V-, 30APROVIDE WATER FILTER SYSTEMPROVIDE APPROVED BACKFLOW PREVENTER FLOOR SINKINDIRECT 59"X27 1/2"X28 3/4"ETL 2.5" CASTER 72 5/8"X30"X37"UL, NSF 5" CASTER 115V-, 5.7AMP, 2/5HP 120V-, 13.5AMP 2.5" CASTER 115V, 5.1A 1/5HP 13"X17 1/2"X6 3/8"NSF 1/2"1/2"DIRECT 84"X25.5"X45"NSF 1/2"1/2"DIRECT 6" LEG 1/2"1/2" PROVIDE APPROVED BACKFLOW PREVENTER ETL 48 1/2"X34 1/4"X50 1/8"NSF 115V- 7.5A, 1/3HP4" CASTER 28 3/4"X27 5/8"X79 7/8"115V, 2.2A 1/5HPETL4" CASTER 23.9"X26.8"X34.6"120V-, 7.3AMP 14"X10"X5"NSF 1/2"1/2"DIRECT 18"X18"X14"NSF 6" LEG PROVIDE APPROVED BACKFLOW PREVENTER FOLLOWING C.D INDIRECT FLOOR SINK1/2"1/2" DIRECTW/ 18" DRAIN BD. FOLLOWING C.D. NSF 1 1 3 1 KTCHNNAID PANASONIC TURBO CHEF ECO SPE-203-161825 MOFF-E35D6-26/2 THE ECO 65"x42"x21"5" CASTER 220V, 3PH, (3) 40AMPINDIRECTFLOOR SINKUL, NSF PROVIDE APPROVED BACKFLOW PREVENTER 1 1 JAC EVERSYS PICOMATIC E4 MOP SINK45 46B 46C WALL MOUNT SHELF 36"1836NK3-METROSEAL WALL MOUNT SHELF 36"1436NK3-METROSEAL 5 3 METRO SUPER ERECTA METRO SUPER ERECTA EAGLE F1916-12 & 312690 EL-5DR KROWNE JOHN BOOS JOHN BOOS 1 54 55 STANDING SHELF (CHROME) 18" x 36" STANDING SHELF (CHROME) 18" x 48" 70 71 STANDING SHELF (GREEN) 18" x 48" STANDING SHELF (GREEN) 18" x 60" 2WALL MOUNT SHELF 24"METRO SUPER ERECTA 1824NK3-METROSEAL 86 86A 87 89 STAINLESS STEEL WALL-MOUNTED SHELF 6" x 36" STAINLESS STEEL WALL-MOUNTED SHELF 6" x 60" 1 1 12X721 90 91 91A 91B 91C WALL MOUNT SHELF 48" 1848NK3-METROSEAL WALL MOUNT SHELF 72" 18X72 WALL MOUNT SHELF 72" 1 2 METRO SUPER ERECTA 1 2 14X72 12X72 STAINLESS STEEL WALL-MOUNTED SHELF 6" x 48"1 7 4 5 4 WALL MOUNT SHELF 72" WALL MOUNT SHELF 72" NSF 4" CASTER26"X20 1/4"X68 5/8" 50 7/8"X28"X78 1/2"NSF 4" CASTER 115V- 15.5A, 3/4HP 30"X28 1/2"X44 1/2"UL, NSF 6" LEG 115V- 10APROVIDE APPROVED BACKFLOW PREVENTER INDIRECT FLOOR SINK WHOLE CAKE SHOWCASE, PB LED LIGHT SHORT CAKE SHOWCASE, PB LED LIGHT BACK LINE (FAN ON FRONT) KITCHEN (FAN ON BACK) PROVIDE WATER FILTER SYSTEM 5-TIER, 12"W x 20"D x 77"H FOLLOWING C.D. FOLLOWING C.D. FOLLOWING C.D. TUC-48-HC UL48 3/8"X30 1/8"X29 3/4"TRUE 115V-, 3AMP, 1/3HP5" CASTER 35 7/8"W x 77 1/2"H x 36 7/8"D NSF, ETL35 7/8"W x 77 1/2"H x 36 7/8"D 220-240V, 60Hz, 12.5kW 208V, 60Hz, 11.2kWNSF, ETL 220-240V, 60Hz, 12.5kW208V, 60Hz, 11.2kW 31 1/2" x 48 3/4" x 77 7/8"ETL 115/60/1 601/2" X 34 1/4" X 50 1/8"NSF 115V- 7.5A, 1/3HP 20.2"W x 22.3"D x 35"H UL, NSF 120V/240V, 60 HERTZ 10"W x 28.4"D x 34"H NSF, ETL 120V, 60 HERTZ 120V, 60 HERTZ9.4"W x 18.6"D x 29.1"H NSF, ETL UL, ETL NSF9.3"W x 13"D x 20.7"H UL16.1"W x 23.5"D x 21.5"H 208/240 VAC, 60Hz, 20AMP 42.425"W x 3.531"D x 23.929"H High Mode: 10” x 14” x 8.6Low Mode: 6.5” x 14” x 8.6”24 Volt NSF8.8"W x20.5"D x 7.5" H GSW USA GSW USA 30"W x 48"L x 35" H 30"W x 36"L x 35" HGSW USA WT-EB3036 NSF ETL NSF ETL 12"W x 20"D x 77" H 18"W x 36"L 14"W x 36"L NSF NSF 18"W x 24"L 18"W x 48"L NSF NSF METRO 4'-0"X1'-6"X6'-0"1848 BR 5 TIES - 18" DEPTHNSF6" LEG 1836 BR 3'-0"X1'-6"X6'-0"5 TIES - 18" DEPTH6" LEGNSFMETRO BLUEAIR 48"X12"WS1248 NSF BLUEAIR 36"X12"WS1236 NSF BLUEAIR 60"X12"WS1260 NSF METRO SUPER ERECTA METRO SUPER ERECTA METRO SUPER ERECTA METRO SUPER ERECTA METRO SUPER ERECTA BELSHAW 27"X40"X64"120V, 3PH, 0.5AMPETL6" LEG 44,000BTU718LCG REGENCY 4'-0"X1'-6"X6'-0"NSF 5 TIES - 18" DEPTH6" LEG REGENCY 5'-0"X1'-6"X6'-0"NSF 5 TIES - 18" DEPTH6" LEG DUMP SINK JOHN BOOS1 20"X16"X12"PB-DISINK201612-X PROVIDE 2 FAUCETNSF-DIRECT 1DIPPER WELL KROWNE 16-149 NSF7 3/16 X 6 3/16 NSFNSF INDIRECT (FLOOR MOUNTED) PROVIDE APPROVED BACKFLOW PREVENTER PROVIDE APPROVED BACKFLOW PREVENTER PROVIDE APPROVED BACKFLOW PREVENTER I N T E R I O R D E S I G N M-1.1 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m ME C H A N I C A L S C H E D U L E S DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T AIR FLOW CFMMARK PANEL SIZEMODELMFRNECK SIZE REMARKS 125-175 225-300 24"X24" 24"X24" PMCTITUS TITUS 8"X8" 10"X10"PMC 0-600 24"X24"50RTITUS - NOTE: 2. 1. 1,2 1,2 1,2 PROVIDE O.B.D. AND PLASTER FRAME IN GYP. BOARD INSTALLATION & MANUAL DAMPER IN T-BAR CEILING INSTALLATION. SELECT DIFFUSERS TO MATCH CEILING COLOR. 1,214"X14"TITUS PMC375-600 24"X24" - S-1 - S-2 - S-3 - R-1 1,2-TITUS S300FS0-300 12"X8"- S-4 250-600 30"X24"350FLTITUS -1,2- R-2 AIR BALANCE SCHEDULE 1 EF-1 1 DU85HFA CAPTIVEAIRE 1800 1.000 1373 ODP 0.750 0.4610 3 208 2.6 570 FPM 99 12.3 FAN UNIT NO TAG QTY FAN UNIT MODEL #MANUFACTURER CFM ESP RPM MOTOR ENCL HP BHP PHASE VOLT FLA DISCHARGE VELOCITY WEIGHT (LBS)SONES 2 KMUA-1 1 A1-15D 15MF-1-MOD A1 -1800 0.400 1807 ODP,PREMIUM 1.000 0.9050 3 208 3.1 3.9A 15A 3.26 95.0°F 68.0°F 75.0°F 68.0°F 471 23 FAN UNIT NO TAG QTY FAN UNIT MODEL #BLOWER HOUSING MIN CFM DESIGN CFM ESP RPM MOTOR ENCL HP BHP PHASE VOLT FLA MCA MOCP EVAP FLOW RATE (Gal/Hr) EVAP COOLER ENTERING DB TEMP EVAP COOLER ENTERING WB TEMP EVAP COOLER LEAVING DB TEMP EVAP COOLER LEAVING WB TEMP WEIGHT (LBS)SONES 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 L3 01REFLECTED CEILING PLAN 1 AB 2 3 L5 L5 1 10'-0" AFF SERVICE COUNTER L5 L5 L5 L5 L5 L5 L7 L7 L2 L2 L2 MIN. 18" 1HR RATED CEILING AROUND HOOD W.I.C. W.I.F. L4 L4 L4 L4 L4 L4 BREAD 10'-0" AFF 2 L2 L2 L2 L2 L2 L2 L2 8'-0" AFF 1 REST ROOM 8'-0" AFF 1 REST ROOM 10'-0" AFF 2 SANDWICH OFFICE 10'-0" AFF 2 3 9'-0" AFF L1 L5 L5 L6 L6 L6 3 10'-0" AFF 2 10'-0" AFF 10'-0" AFF OPEN L5 L5 L5 9'-0" AFF 8'-0" AFF 1 4 4 6 8'-0" AFF L5 L5 L5 L5 L5 L5 L5 L5 L5 L5 L5 L5 L5L5 L5 L5 L5 L5 3 EXP. AFF L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3L3 L3 1 10'-6" AFF 3 10'-0" AFF L1 L1 L1 L7 L7 L7 L7 L7 L7 L7 L7 L5 L5 L5 L5 L5 L7 L7 L7 L7 L7 L7 L8 L8 L8 L8 L9 L9 1 2 3 100 CFM 400 CFM 14"Ø 10"Ø 300 CFM 350 CFM 350 CFM 300 CFM 80 CFM 80 CFM 100 CFM 320 CFM 480 CFM 900 CFM 900 CFM 18"X14" 14"Ø EAD DUCT UP TO KEF ON ROOF 1800 CFM 18X14 SAD DUCT FROM MAU ON ROOF TO CEILING SPACE WITH 3M FIRE RATED WRAP KEF 1 300 CFM 200 CFM 460 CFM 320 CFM 60 CFM 10"Ø 10"Ø 6"Ø 12"Ø 16"Ø 10"Ø 6"Ø 6"Ø 8"Ø 10"Ø 12"Ø 18"Ø 10"Ø 14"Ø 14"Ø 10"Ø 10"Ø 10"Ø10"Ø 16"Ø 14"Ø 18"Ø 18"Ø EXHAUST OUTLETS SERVING GREASE DUCT SYSTEMS SHALL TERMINATE ABOVE THE ROOF SURFACE, 10 FEET FROM PROPERTY LINE, 10 FEET FROM AIR INTAKE OPENINGS AND 10 FEET ABOVE ADJOINING GRADE. BASE OF FAN SHALL BE 40 INCHES ABOVE ROOF SURFACE. LAMC 510.9.1 NON-GREASE DUCTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH SMACNA-2006 OR UL 181 LAMC 602.1 6"Ø UP THROUGH ROOF WITH BACKDRAFT DAMPER TERMINATEWITH GOOSE NECK FACING DOWN 12"ABOVE ROOF NOTE: DUCT TRUNKS FROM RTU ON ROOF TO CEILING SPACE CONNECT TO EXISTING DUCT TRUNKS FROM RTU ON ROOF TO CEILING SPACE MVD (TYP) MVD (TYP) MVD (TYP) 12"Ø 16"Ø8"Ø 16"Ø 8 FEET LINEAR DIFFUSER RTU 2 OPERATING WEIGHT 600# (NEW)(E) OPERATING WEIGHT 176# 1800CFM 1800CFM ENVIROMENTAL EXHAUST OUTLETS SHALL TERMINATE NO LESS THAN 3 FEET FROM PROPERTY LINE, 3 FEET FROM OPENINGS INTO BUILDING AND 10 FEET FROM ANY FORCE INTAKE. OUTSIDE AIR FOR HEATING OR COOLING SYSTEM SHALL NOT BE TAKEN FROM LESS THAN 10 FEET IN DISTANCE FROM APPLIANCE VENT OUTLET, A VENT OF A PLUMBING DRAINAGE SYSTEM, THE DISCHARGE OUTLET OF AN EXHAUST FAN, OR MEDICAL-SURGICAL VACUUM OUTLET UNLESS THE OUTLET IS 3 FEET ABOVE THE OUTSIDE AIR INLET. THE AIR FILTERS FOR OUTSIDE ANS RETURN AIR HAVE A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 13. CMC 401.2, TITLE 24 SEC.120.0 (B) 1C; 1200(C) 1 B; 150.0(M) 12 C NOTE: 6"Ø UP THROUGH ROOF WITH BACKDRAFT DAMPER TERMINATE WITH GOOSE NECK FACING DOWN 12" ABOVE ROOF I N T E R I O R D E S I G N M-2 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m KI T C H E N E Q U I P M E N T P L A N DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T MECHANICAL FLOOR PLANMECHANICAL ROOF PLAN 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 NOT TO SCALE WELD OR BRAZE ALL DUCT JOINTS AND SEAMS ON THE EXTERNAL SURFACE. DO NOT PENETRATE DUCT WALLS WITH SCREWS, NAILS, ETC. SECTIONS OF DUCT SHALL NOT CONTAIN GREASE POCKETS. GREASE DUCTS SHALL COMPLY WITH 2013 CMC CHAPTER 5 REQUIREMENTS. NOTES: (TYPICAL) 6" MIN. ROOF AT POINT OF PENETRATION P.O.C 48" MAX. CEILING METAL SHIELD OR COLLAR LOW VOLTAGE CONTROL WIRES AND CONDUITS BY MECHANICAL CONTRACTOR. 3M DUCT WARP 615+ WHEN SLOPE DUCT OCCURS TO HOOD MINIMUM 1/4" PER LINEAR FOOT IF RUN IS LESS THAN 75 FT. SLOPE 1" PER LINEAR FOOT IF RUN IS MORE THAN 75 FT. MIN. 22 GAGE STAINLESS STEEL KITCHEN EXHAUST HOOD MIN. 22 GAGE STAINLESS STEEL SOLID FLASHING FOR HOODS LESS THAN 12" FROM CEILING OR WALL (TYPICAL) 18 GAGE STAINLESS STEEL KITCHEN EXHAUST DUCT WELD ALL DUCT JOINTS & SEAMS ON THE EXTERNAL SURFACE. DO NOT PENETRATE DUCT WALLS WITH SCREWS, NAILS ETC. CLEANOUT DOORS IN DUCTS SHALL BE SLIDING OR HINGED PROVIDE ACCESS TO ALL DUCT CLEANOUTS PROVIDE ADEQUATE CLEANOUT OPENINGS FOR THOROUGH DUCT SYSTEM CLEANING. MINIMUM ONE EVERY 12 FT. OF STRAIGHT DUCT & ONE AT EACH CHANGE OF DIRECTION. MINIMUM VELOCITY 1500 FPM & MAX. 2000 FPM. NOT TO SCALE TRAILING 3/4" FLAT 1-1/2" TYP. EDGE (TYP.) CHANNEL 1-1/2" TYP. RUNNER CRIMP (TYP.) FLO W R=2" VANES AND FRAMES - 24 GAUGE. WELDED TO ELBOW. FRAMES AND CHANNELS - BOLTED OR TACK MAXIMUM UNSUPPORTED VANE LENGTH 36". TURNING VANES FLOW VANED ELBOW NOTES: FRAME NOT TO SCALE NOT TO SCALE BIRD SCREEN SCREW (TYP. 8 PLACES) W/ 1/4"Øx3/4" LONG LAG THK.<ANCHOR TO STRUCT1 1/2"x1 1/2"x1/4" TRANSITION FITTING 4" MIN. SEE PLAN FOR SIZE EXHAUST DUCT (TYP. FOR 4)SLACK CABLE 1/8"Ø SEISMIC CEILING SPACE ROOF SUPPORT EXHAUST FAN (4) #12 GA. WIRES TO EXHAUST FAN ROOF JACK DISCHARGE LAG TO 4" HIGH ROOF CURB (4" HIGH MIN.) NOTE: SECURE DIFFUSER WITH SUPPORT WIRE (TYPICAL) ACOUSTICAL FLEX. DUCT VOLUME DAMPER CEILING SPIRAL DUCT 4" WIDE SHEET METAL STRAP CLAMPING DEVICE (TYP.) RETURN AIR REGISTER INSTALLATION SIMILAR 5'-0" MAXIMUM LENGTH 1. CUT THE FIRST LAYER OF DUCT WRAP TO A LENGTH SUFFICIENT TO WRAP COMPLETELY AROUND THE PERIMETER OF THE DUCT, PLUS PROVIDE AN OVERLAP OF NOT LESS THAN 3 INCHES. USE ALUMINUM FOIL TAPES TO SEAL CUT EDGES OF THE BLANKET. ROLL OUT DUCT WRAP MATERIAL TAUTLY BEFORE MEASURING TO MINIMIZE WASTE. HOLD THE FIRST LAYER WRAP OF DUCT WRAP IN PLACE USING FILAMENT TAPE. SPACE THE TAPE 1?INCHES FROM THE EDGES OF EACH BLANKET AND MIDWAY BETWEEN 10?INCHES ON CENTER. CUT THE NEXT ADJACENT INTERIOR WRAP TO COMPLETELY WRAP AROUND THE PERIMETER OF THE DUCT WITH ENOUGH EXCESS TO PROVIDE AN OVERLAP OF NOT LESS THAN 3 INCHES. A 3-INCH LONGITUDINAL OVERLAP ONTO THE PREVIOUS ADJACENT WRAP IS REQUIRED ON BOTH LAYERS. 2. CUT THE SECOND LAYER OR TO SUFFICIENT LENGTH TO WRAP COMPLETELY AROUND THE PERIMETER OF THE INTERIOR WRAP WITH SUFFICIENT EXCESS TO PROVIDE AN OVERLAP OF NOT LESS THAN 3 INCHES. INSTALL DUCT WRAP AS THE EXTERIOR LAYER SHALL BE CUT, IF NEEDED, AND PROPERLY LOCATED TO ENSURE THAT THE LONGITUDINAL OVERLAP JOINTS OF THE EXTERIOR LAYER OF BLANKET ARE STAGGERED 10? INCHES FROM THOSE OF THE INTERIOR LAYER. USE ALUMINUM FOIL TAPE TO SEAL ANY CUT EDGES OF THE BLANKET. POSITION THE EXTERIOR LAYER SUCH THAT THE PERIMETER OVERLAP JOINTS ARE SPACED AT LEAST 12 INCHES FROM THOSE OF THE INTERIOR LAYER. 3. USE FILAMENT TAPE AS A TEMPORARY HOLD PRIOR TO BANDING TO EASE INSTALLATION. 4. HOLD THE EXTERIOR DUCT WRAP IN PLACE USING BANDING MATERIAL. PLACE THE BANDS 1?INCHES FROM EACH BLANKET EDGE AND MIDWAY BETWEEN 10?INCHES ON CENTERS. THE TENSION OF THE BANDING MATERIAL SHALL BE SUFFICIENT TO HOLD DUCT WRAP SNUGLY IN PLACE, BUT NOT CAUSE ANY CUTTING OR DAMAGE TO THE BLANKET. 5. NOTE THAT SUPPORT HANGER SYSTEMS DO NOT NEED TO BE WRAPPED PROVIDED THE HANGER RODS ARE AT LEAST A MINIMUM OF 3/8-IN. DIAMETER AND THE ANGLE IRON IS A MINIMUM OF 1?IN. X 1?IN. X 1/8-IN. TWO LAYERS OF DUCT WRAP FILAMENT TAPE OF 34-IN WITH MINIMUM BANDING OF BARBON STEEL OF 34-IN. WIDTH AND 0.015-IN. THICKNESS, AND BANDING CLIPS PERIMETER OVERLAP OF 3 INCHES LONGITUDINAL OVERLAP OF 3 INCHES HANGER ROD OF 3/8-INCH SIZE MINIMUM DUCT SUPPORT ANGLE, 112" x 112" x 18" MIN. DOOR OPENING AT GREASE DUCT STEEL ANGLE OPENING FRAME - WELD TO DUCT. ALL THREADED ROD OF ?INCH DIA. SIZE, 4?TO 5 INCHES LONG - WELD TO THE CORNERS OF THE PERIMETER REINFORCEMENT FRAME OF THE DOOR OPENING. (4 PLACES) ACCESS COVER OF 16 GAGE STEEL INSULATION PINS OF COPPER-COATED STEEL, 10 GAGE, 4 TO 5 INCHES LONG - WELD TO THE DOOR PANEL FOR BLANKET INSTALLATION. TURN DOWN PINS THAT EXTEND BEYOND THE OUTER DUCT WRAP TO AVOID SHARP EDGES ON THE DOOR. FIRST LAYER DUCT WRAP - CUT AS 1-INCH STEP JOINT CONSTRUCTION AND IMPALE OVER THE INSULATION PINS ON THE DOOR PANEL TO ALLOW FOR A TIGHT FIT AND NO THROUGH OPENINGS. SECOND LAYER DUCT WRAP - CUT AS 1-INCH STEP JOINT CONSTRUCTION AND IMPALE OVER THE INSULATION PINS ON THE DOOR PANEL TO ALLOW FOR A TIGHT FIT AND NO THROUGH OPENINGS. THIRD LAYER DUCT WRAP - CUT AS 1-INCH STEP JOINT CONSTRUCTION AND IMPALE ON TOP OF THE TWO PREVIOUS DOOR PANEL LAYERS AND OVERLAP OF NOT LESS THAN 1 INCH AROUND THE PERIMETER OF THE DOOR OPENING. SPEED CLIPS OF MINIMUM 1?IN. x 1?-IN. SQUARE OR 1?INCH DIAMETER SIZE TO LOCK THE BLANKET LAYERS IN PLACE. ALUMINUM TAPES COVERING ALL EXPOSED EDGES HOLLOW STEEL TUBING OF 4-INCH LENGTH FOR THREADED RODS TO ACT AS PROTECTION SLEEVES FOR DUCT WRAP WHEN FASTENING THE DOOR. WING NUT OF ?INCH DIA. SIZE 1. CUT TWO LAYERS OF DUCT WRAP AS 1-INCH STEP JOINT CONSTRUCTION AND IMPALE OVER THE INSULATION PINS ON THE DOOR PANEL TO ALLOW FOR A TIGHT FIT AND NO THROUGH OPENINGS. 2. CUT A THIRD LAYER OF 3M FIREMASTER DUCT WRAP IN A LIKE MANNER, IMPALE ON TOP OF THE TWO PREVIOUS DOOR PANEL LAYERS AND OVERLAP OF NOT LESS THAN 1 INCH AROUND THE PERIMETER OF THE DOOR OPENING. THEN, LOCK THE BLANKET LAYERS IN PLACE WITH MINIMUM 1?IN. X 1?-IN. SQUARE OR 1?INCH DIAMETER ROUND SPEED CLIPS. TURN DOWN INSULATION PINS THAT EXTEND BEYOND THE OUTER DUCT WRAP TO AVOID SHARP EDGES ON THE DOOR. 3. APPLY ACCESS DOOR LABELS TO ALL ACCESS CLEAN OUT DOORS. NOTES 18" MIN. DEEP FRYER (E) 1 HR. FIRE RATED WALL 3" 3M DUCT WARP 615+ 3M DUCT WARP 615+ GREASE DUCT TO EXTEND 18" MIN ABOVE ROOF NOT TO SCALE (N) QUARRY TILE FINISH OVER CONC. FLOOR 18" CLEARANCE TO NON-COMBUSTIBLE 22 GAGE STAINLESS STEEL SOLID AND SEALED AROUND HOOD OR FIREMASTER FASTWRAP XL OR FIREMASTER FASTWRAP XL I N T E R I O R D E S I G N M-3 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m DE T A I L S DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 1 H-1 6024 ND-2 CAPTIVEAIRE 11' 0"450 DEG I MEDIUM 164 1800 4"14"1800 1684 -0.834"430 SS WHERE EXPOSED ALONE ALONE HOOD NO TAG MODEL MANUFACTURER LENGTH MAX COOKING TEMP TYPE APPLIANCE DUTY DESIGN CFM/FT TOTAL EXH CFM EXHAUST PLENUM RISER(S) WIDTH LENG HEIGHT DIA CFM VEL SP HOOD CONSTRUCTION HOOD CONFIG END TO END ROW 1 H-1 CAPTRATE SOLO FILTER 8 16"16"85% SEE FILTER SPEC 3 RECESSED ROUND NO RIGHT 12"x60"x24"TANK FS 4.0/4.0 DCV-1111 1 LIGHT 1 FAN YES 832 LBS HOOD NO TAG FILTER(S) TYPE QTY HEIGHT LENGTH EFFICIENCY @ 7 MICRONS LIGHT(S) QTY TYPE WIRE GUARD UTILITY CABINET(S) LOCATION SIZE FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL # SWITCHES QUANTITY FIRE SYSTEM PIPING HOOD HANGING WEIGHT 1 H-1 LEFT END STANDOFF (FINISHED) 1" WIDE 60" LONG INSULATED. RIGHT VERTICAL END PANEL 27" TOP WIDTH, 21" BOTTOM WIDTH, 80" HIGH INSULATED 430 SS. LEFT WALL AS END PANEL. HOOD NO TAG OPTION 1 FS-1 TANK FS 4.0/4.0 37 FIRE CABINET RIGHT RIGHT, HOOD 1 FIRE SYSTEM NO TAG TYPE SIZE FLOW POINTS INSTALLATION SYSTEM LOCATION ON HOOD 1 FS-1 SC ELECTRICAL 2.000 CAPTIVEAIRE SYSTEMS FIRE SYSTEM NO TAG TYPE SIZE SUPPLIED BY 1 EF-1 1 DU85HFA CAPTIVEAIRE 1800 1.000 1373 ODP 0.750 0.4610 3 208 2.6 570 FPM 99 12.3 FAN UNIT NO TAG QTY FAN UNIT MODEL #MANUFACTURER CFM ESP RPM MOTOR ENCL HP BHP PHASE VOLT FLA DISCHARGE VELOCITY WEIGHT (LBS)SONES FOR QUESTIONS CALL: PHONE: 310.876.8505 REFERENCE JOB NUMBER ANDREW WYSOPALLOS ANGELES SALES OFFICE REG81@CAPTIVEAIRE.COM Operation of All CaptiveAire Equipment to be Verified by Factory Service Technician. Equipment Must be Operational and Fire System shall be Hooked-up and Armed. Report to be Sent to Customer by Manufacturer When Complete. , . NOTE- Exhaust Collar Must be Factory Installed. If A Different Size Or Location is Required, Please Note Change On Submittal. Rear Discharge Is Available. Contact CaptiveAire For Possible Locations. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E BU I L T NFP A WIT H IN R 5700997 MASTER DRAWING asw-81 Pa r i s B a g u e t t e - A r c a d i a , C A 17 L a s T u n a s D r i v e , Lo s A n g e l e s O f f i c e 18 1 0 1 4 t h S t S u i t e 2 1 4 , S a n t a M o n i c a , C A , 9 0 4 0 4 P H O N E : ( 3 1 0 ) 8 7 6 - 8 5 0 5 F A X : ( 9 1 9 ) 7 4 7 - 5 6 3 9 E M A I L : r e g 8 1 @ c a p t i v e a i r e . c o m Ar c a d i a , C A , 9 1 0 0 7 2 RTU-1 1 CASRTU1-18-6T-DOAS CAPTIVEAIRE 18MF-1-RTU 0 1800 1800 1288 1.500 2.00 3 208 33.2A 35A 95.0°F 68.0°F 52.4°F 52.4°F 52.5°F 80.1 MBH 78.4 MBH 19.5 9.2 70.0°F 61.7°F 35.1 MBH 56 MBH 1.5 LBS/HR 50.0°F 31.0°F 81.0°F 5.7 1,2,3,4,5,6,7,8,9,10,11,12,13 NOTES: 1. INVERTER SCROLL COMPRESSOR WITH INTEGRATED OIL SENSOR. DIGITAL OR STAGED SCROLL NOT AN APPROVED EQUAL 2. DIRECT DRIVE PLENUM BLOWER. BELT DRIVEN BLOWERS ARE NOT ACCEPTABLE 3. INTEGRATED MONITORING VIA CELLULAR CONNECTION BY MANUFACTURER 4. REFRIGERATION PRESSURE MONITORING ON HIGH AND LOW PRESSURE SIDE OF SYSTEM INCLUDED THROUGH DIGITAL INTERFACE 5. EC MOTOR CONDENSING FANS 6. ELECTRONIC EXPANSION VALVE. TXV NOT ACCEPTABLE 7. SUCTION LINE ACCUMULATOR 8. FACTORY COMMISSIONING WITH 5 YEAR PARTS WARRANTY 9. AVERAGING INTAKE, EVAP AND DISCHARGE TEMPERATURE SENSORS (DISCHARGE SENSOR TO BE FACTORY MOUNTED WITHIN UNIT) 10. SUPPLY CFM MONITORING INTEGRAL TO UNIT WITH CFM MEASUREMENT INCLUDED THROUGH DIGITAL INTERFACE 11. FULLY MODULATING HOT GAS REHEAT 12. 1" EXTERIOR DUAL-WALL CONSTRUCTION W/ R-4.3 INSULATION– MINIMUM 24GA EXTERIOR W/ 18GA BASE 13. DOWN DISCHARGE/NO RETURN FAN INFORMATION FAN UNIT NO TAG QTY DOAS/RTU MODEL #MANUFACTURER BLOWER RETURN AIR CFM MAX OUTSIDE AIR CFM TOTAL CFM WEIGHT (LBS)ESP ELECTRICAL INFORMATION HP PHASE VOLT MCA MOCP COOLING INFORMATION OUTSIDE AIR DB WB LEAVING AIR DB WB DP CAPACITY TOTAL SENS.IEER ISMRE REHEAT INFORMATION DISCHARGE DB WB CAPACITY DESIRED MAX MOISTURE REMOVAL RATE HEAT PUMP INFORMATION ENTERING TEMP MAX TEMP RISE DISCHARGE TEMP COP NOTES 1 2 EF-1 RTU-1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 GREASE BOX FAN BASE CERAMIC SEAL - INSTALLED AT PLANT - FOR GREASE DUCTS 2 YEAR PARTS WARRANTY RTU TOTAL CFM MONITORING SINGLE POINT ELECTRICAL CONNECTION FOR RTU. 750VA TRANSFORMER USED. IF A NON-DCV PREWIRE CONTROLS THIS UNIT, THE #28, #47, "MA", OR "E2" PREWIRE OPTION MUST BE SELECTED. DOES NOT PROVIDE SUPPLY STARTER IN PREWIRE CASLINK BUILDING MONITORING SYSTEM - INTERNET OR CELLULAR CONNECTION REQUIRED 2" MERV 13 FILTERS FOR RTU1 (QTY. 4) 2" MERV 8 FILTERS FOR RTU1 (QTY. 4) OVERHEAT STAT VFD FACTORY MOUNTED AND WIRED IN RTU COMMERCIAL CONTROL VESTIBULE RTU1 DOWN DISCHARGE RTU FIXED 100% OA INTAKE CONTROL RTU1 NO RETURN - 100% OA REMOTE TEMPERATURE AND HUMIDITY SPACE SENSOR 6 TON MODULATING COOLING OPTION WITH HEAT PUMP, 208/230V. R410A REFRIGERANT, VARIABLE SPEED COMPRESSOR, ECM CONDENSING FANS 6 TON MODULATING REHEAT OPTION WITH HEAT PUMP - SPACE DEWPOINT CONTROL RTU1 CURB DUCT HANGER OCCUPIED SCHEDULING COMMERCIAL SMOKE DETECTOR/ALARM INTERLOCK - ALARM SUPPLIED BY OTHERS CLOGGED FILTER SWITCH - NOTIFICATION ON HMI RTU1 CONVENIENCE OUTLET (GFCI), 15 AMP - REQUIRES SEPARATE 120V CONNECTION. INCLUDES RECEPTACLE, COVER AND J BOX VAV PACKAGE W/ 0-10VDC INPUT CONTROL (571 VFD INCLUDED) 5 YEAR ENTIRE UNIT PARTS WARRANTY, 10 YEAR ENTIRE UNIT PARTS WARRANTY WITH REMOTE MONITORING AND CAPTIVEAIRE SERVICE CONTRACT FAN UNIT NO TAG QTY DESCRIPTION 1 2 # 1 # 2 EF-1 RTU-1 36 LBS 59 LBS CURB CURB 23.000"W X 23.000"L X 20.000"H ALONG LENGTH, RIGHT VENTED HINGED. 41.000"W X 71.000"L X 14.000"H ALONG WIDTH, RIGHT INSULATED. NO ON FAN TAG WEIGHT ITEM SIZE I N T E R I O R D E S I G N M-4 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m HO O D I N F O R M A T I O N DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 1500500 FLOW RATE (CFM) 1000 0.00 0 0.50 PR E S S U R E D R O P ( i n . H 2 0 ) PRESSURE DROP VS. FLOW RATE RRSPECIFICATION: CAPTRATE GREASE-STOP SOLO FILTER A UNIQUE S-BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN, THE CAPTRATE GREASE-STOP SOLO FILTER IS A SINGLE-STAGE FILTER FEATURING LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE. FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICRONS IN SIZE, AND 85% GREASE PARTICLES SEVEN MICRONS IN SIZE AND COMPONENTS WHEN ASSEMBLED. 2-INCH DEEP HOOD CHANNEL(S). TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY. UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO FR A C T I O N A L E F F I C I E N C Y ( % ) 0 0.1 20 40 1.0 PARTICLE DIAMETER (UM) 10.0 EFFICIENCY VS. PARTICLE DIAMETER 60 80 100 THE CAPTRATE GREASE-STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05. TE A NSF ACCORDANCE No. 96 NFPA WITH BUILT IN SLI DTE RO CH B N RAN I,OR M . YR OR LAIGNTSB AT CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH:. NFPA #96. NSF STANDARD #2. UL STANDARD #1046. INT. MECH. CODE (IMC). ULC-S649. 1.00 1.50 2.00 2.50 3.00 3.50 MANUFACTURER APPROVED FOR USE IN SOLID FUEL APPLICATIONS AS A SPARK ARRESTER. 11' 0"NOM./11' 0.00"OD. 12'-1.00" OVERALL LENGTH 60" 12" UTILITY CABINET. 1" LAYER OF INSULATION FACTORY INSTALLED IN 1.00" END STANDOFF MEETS 0" REQUIREMENTS CLEARANCE TO COMBUSTIBLE SURFACES. 1" 3" § 66"66" 10 1/2" Ø14" U.L. LISTED RECESSED ROUND LED FIXTURE AND LED LIGHT. INSTALLER MUST CONFIRM HOOD IS INSTALLED SUCH THAT THE SPECIFIED WALL, ACTING AS AN END PANEL, IS MATED TIGHT TO THE CORRECT END OF HOOD TO ACHIEVE A REDUCED MINIMUM EXHAUST CFM LISTING. NON-COMPLIANCE WILL NULLIFY THE ETL LISTING, VOID THE MANUFACTURER'S WARRANTY, AND HOLD THE CONTRACTOR LIABLE FOR ANY AND ALL LOSSES, COSTS, AND EXPENSES RELATED TO THE NON-CONFORMANCE OF THE MANUFACTURER'S SPECIFIED INSTRUCTION. THE WALL ACTING AS AN END PANEL MUST EXTEND NO LESS THAN 20" FROM THE INTERSECTING WALL ON WHICH HOOD IS MOUNTED AND MUST EXTEND NO LESS THAN 20" UNDER BOTTOM OF HOOD TO BE ELIGIBLE FOR REDUCED MINIMUM EXHAUST CFM LISTING. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. HOOD CORNER HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). HOOD CORNER HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. FULL LENGTH HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). FULL LENGTH HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR FULL LENGTH HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) 3" INTERNAL STANDOFF. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. §EXHAUST RISER. HANGING ANGLE. RECESSED ROUND LED FIXTURE AND LED LIGHT, 3500 K WARM OUTPUT. 20" 4" 4 1/2" 21" 27" 80" RIGHT VERTICAL END PANEL WITH ADJUSTABLE LEGS. GAS CHASE CUTOUT (FOR GAS AND POWER LINES). LEFT WALL AS END PANEL. EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 60" IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 16" CAPTRATE SOLO FILTER WITH HOOK. 4.166"Shelf With 2.25"Condensate MUA 2.25" 2.25"2.25" 4.166" IN THE FOLLOWING LOCATIONS FOR WALL CANOPIES HANGING ANGLES WILL BE LOCATED REAR FROM DIM Only Back OnlyExhaust MUA With Wall Exhaust HOOD STYLE DIM DIM 2.25"2.25" 2.25"2.25" Hood)Hood) 2.25"2.25" (24" High FRONT FROM (30" High FRONT FROM GREASE CUP WILL BE SUPPORTED BY TWO STUDS ON THE INSIDE WALL OF THE HOOD. THE GREASE WILL DRAIN THROUGH A CONCEALED GREASE TROUGH AND INTO THIS REMOVEABLE/CLEANABLE CUP. MC Intertek I T A N S TED ION L SIAT RE S I S T A N C E ( i n . H 2 0 ) CAPTRATE R AIRFLOW (cfm) 0.2 0.4 400 0 0 200 600 800 1000 0.6 0.8 1.2 1 1.4 RESISTANCE VS. AIRFLOW 1.6 2" Captrate Grease-Stop Solo FilterRR Captrate Grease-Stop Solo Filter 1/2" - 13 TPI GRADE 5 (MINIMUM)STEEL HEX NUT 1/2" GRADE 5(MINIMUM) STEEL FLAT WASHER 1/2" - 13 TPIGRADE 5 (MINIMUM) STEEL HEX NUTS 1/2" GRADE 5(MINIMUM) STEELFLAT WASHER 1/2" - 13 TPI GRADE 5 (MINIMUM)STEEL ALL-THREAD HOOD CORNERHANGING ANGLE(WEIGHT BEARING ANCHOR POINTFOR HOOD) HOOD CORNER HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM)STEEL HEX NUTS 1/2" GRADE 5 (MINIMUM) STEELFLAT WASHER (HARDWARE BY INSTALLER) NOTE: SEE INSTALLATION MANUAL FOR MORE INFORMATION 4.166"Shelf With 2.25"Condensate MUA 2.25" 2.25"2.25" 4.166" IN THE FOLLOWING LOCATIONS FOR WALL CANOPIES HANGING ANGLES WILL BE LOCATED REAR FROM DIM Only Back OnlyExhaust MUA With Wall Exhaust HOOD STYLE DIM DIM 2.25"2.25" 2.25"2.25" Hood)Hood) 2.25"2.25" (24" High FRONT FROM (30" High FRONT FROM GREASE CUP WILL BE SUPPORTED BY TWO STUDS ON THE INSIDE WALL OF THE HOOD. THE GREASE WILL DRAIN THROUGH A CONCEALED GREASE TROUGH AND INTO THIS REMOVEABLE/CLEANABLE CUP. MC Intertek I T A N S TED ION L SIAT RE S I S T A N C E ( i n . H 2 0 ) CAPTRATE R AIRFLOW (cfm) 0.2 0.4 400 0 0 200 600 800 1000 0.6 0.8 1.2 1 1.4 RESISTANCE VS. AIRFLOW 1.6 2" Captrate Grease-Stop Solo FilterRR Captrate Grease-Stop Solo Filter 1/2" - 13 TPI GRADE 5 (MINIMUM)STEEL HEX NUT 1/2" GRADE 5(MINIMUM) STEEL FLAT WASHER 1/2" - 13 TPIGRADE 5 (MINIMUM) STEEL HEX NUTS 1/2" GRADE 5(MINIMUM) STEELFLAT WASHER 1/2" - 13 TPI GRADE 5 (MINIMUM)STEEL ALL-THREAD HOOD CORNERHANGING ANGLE(WEIGHT BEARING ANCHOR POINTFOR HOOD) HOOD CORNER HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM)STEEL HEX NUTS 1/2" GRADE 5 (MINIMUM) STEELFLAT WASHER (HARDWARE BY INSTALLER) NOTE: SEE INSTALLATION MANUAL FOR MORE INFORMATION SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E BU I L T NFP A WIT H IN R 5700997 MASTER DRAWING asw-81 Pa r i s B a g u e t t e - A r c a d i a , C A 17 L a s T u n a s D r i v e , Lo s A n g e l e s O f f i c e 18 1 0 1 4 t h S t S u i t e 2 1 4 , S a n t a M o n i c a , C A , 9 0 4 0 4 P H O N E : ( 3 1 0 ) 8 7 6 - 8 5 0 5 F A X : ( 9 1 9 ) 7 4 7 - 5 6 3 9 E M A I L : r e g 8 1 @ c a p t i v e a i r e . c o m Ar c a d i a , C A , 9 1 0 0 7 I N T E R I O R D E S I G N M-5 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m HO O D I N F O R M A T I O N DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 §GREASE DUCT SPECIFICATIONS: PROVIDE GREASE DUCT EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW" ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK. MODEL "DW" IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP LOCKING CONNECTIONS SEALED WITH 3M FIRE BARRIER 2000 PLUS. MODEL "DW" DOES NOT REQUIRE WELDING PROVIDING IT HAS BEEN INSTALLED PER THE MANUFACTURES INSTALLATION GUIDE. PROVIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTION AND EVERY 12' ON CENTER. PER MANUFACTURES LISTING MODEL "DW" HORIZONTAL RUNS LESS THAN 75 FT. CAN BE SLOPED 1/16" PER 12", HORIZONTAL RUNS MORE THAN 75 FT. CAN BE SLOPED 3/16" PER 12". DUCT SHOULD BE SLOPED AS MUCH AS POSSIBLE TO REDUCE THE CHANCE OF GREASE ACCUMULATION IN HORIZONTAL RUNS. IF THE DUCT IS WITHIN 18 INCHES OF COMBUSTIBLE MATERIAL, PROVIDE UL-2221 LISTED DOUBLE WALL GREASE DUCT EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW- 2R, 3R, OR 3Z" ROUND 20 GAUGE 430 STAINLESS INNER DUCT INSULATED WITH A 24 GAUGE 430 STAINLESS OUTER SHELL. CAPTIVEAIRE SYSTEMS RECOMMENDS THE USE OF LISTED, PRE-FABRICATED ROUND GREASE EXHAUST DUCT TO REDUCE STATIC PRESSURE IN THE SYSTEM, MINIMIZE INSTALLATION AND INSPECTION TIMES, AND ENSURE DUCT IS LIQUID TIGHT The Double Wall Ductwork Series has been certified by ITS. This certification mark indicates that the product has been tested to and has met the minimum requirements of a widely recognized (consensus) U.S. Product safety standard, that the manufacturing site has been audited, and that the applicant has agreed to a program of periodic factory follow-up inspections to verify continued performance. Models DW-2R and DW-3R are ETL Listed under file number 1000082319SAT-006 EEV and comply with UL1978 and UL2221 Standards. Model DW-3Z is ETL Listed under file number 1000082319SAT-006 EEV and complies with UL1978, UL2221 and CAN/ULC-S144 Standards. SINGLE WALL FACTORY BUILT DUCTWORK - FOR A COMPLETE LIST OF APPROVED SUPPORT METHODS, SEE THE INSTALLATION AND OPERATION MANUAL. - DUCTWORK SHALL SLOPE NOT LESS THAN 1/16" PER LINEAR FOOT TOWARDS THE HOOD OR AN APPROVED GREASE COLLECTION RESERVOIR. - WHERE HORIZONTAL DUCTS EXCEED 75 FEET IN LENGTH, THE SLOPE SHALL NOT BE LESS THAN 3/16" PER LINEAR FOOT. - ALL DUCTWORK IS REQUIRED TO BE INSTALLED WITH THE MAXIMUM SUPPORT SPACING LISTED BELOW. DUCT DIAMETER 8"10'10'24' 10"10'10'24' 12"10'10'24' 14"10'10'24' 16"10'10'24' 18"10'10'24' 20"10'10'24' 22"10'10'24' 24"10'10'24' HORIZONTAL SUPPORT (ft) VERTICAL WALL SUPPORT (ft) VERTICAL CURB SUPPORT (ft) HORIZONTAL VERTICAL TYPE DUCT DIAMETER SUPPORT SPACING (ft) 2R & 2R HT 8"7' 10"7' 12"7' 14"7' 16"7' 18"5' 20"5' 22"5' DOUBLE WALL FACTORY BUILT DUCTWORK - ALL DUCTWORK IS REQUIRED TO BE INSTALLED WITH THE MAXIMUM SUPPORT SPACING LISTED BELOW. - FOR A COMPLETE LIST OF APPROVED SUPPORT METHODS, SEE THE ENTIRE INSTALLATION AND OPERATION MANUAL - DUCTWORK SHALL SLOPE NOT LESS THAN 1/16" PER LINEAR FOOT TOWARDS THE HOOD OR AN APPROVED GREASE COLLECTION RESERVOIR. - WHERE HORIZONTAL DUCTS EXCEED 75 FEET IN LENGTH, THE SLOPE SHALL NOT BE LESS THAN 3/16" PER LINEAR FOOT. 24"5' WALL SUPPORT (ft) CURB SUPPORT (ft) FLOOR SUPPORT (ft) 20'24'24' 3R 10'24'24' 3Z 10'24'24' Furnish double wall, factory built grease duct for use with Type I kitchen hoods, which conforms to the requirements of NFPA-96. Products shall be ETL listed to UL-1978 and UL-2221 for venting air and grease vapors from commercial cooking operation. Models DW-2R, 3R and 3Z are used for grease duct applications when installed in accordance with these instructions and National Fire Protection Association "NFPA 96"; Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations. Double wall grease ducts are listed for a continuous internal temperature of 500 degrees F and intermittent temperatures of 2000 degrees F. The duct sections shall be constructed of an inner duct wall and an outer wall with insulation in between. The inner duct wall shall be constructed of .036 inch thick, 430 type stainless steel and be available in diameters 8" through 24". The outer wall shall be constructed of stainless steel at a minimum of .024 inch thickness. The duct, based on model number, shall include layers of Super Wool 607 Plus insulation between the inner and outer wall. Grease duct joints shall be held together by means of formed V clamps and sealed with 3M Fire Barrier 2000+. The duct wall assembly shall be tested and listed at ¾" or zero inch clearance, according to classifications. Classifications and Clearances UL 2221: Standard for Fire Resistive Grease Duct Enclosure Assemblies. Chapter 7 of this standard references a test labeled Internal Fire Test. Section 7.1.1 references two installation conditions, Condition A and Condition B. Condition A represents all installation condition except for installation within non-ventilated combustible enclosures. Condition B represents installation within a non-ventilated combustible enclosure. Model DW-2R is classified under UL2221 (Test of Fire Resistive Duct Enclosure Assemblies) as an alternate to 2-Hr. fire resistive shaft enclosures with a reduced clearance to combustibles (sizes 8" to 16" diameter). Model 2R is listed in accordance with the requirements for duct enclosure Condition B. AIR F L O W AIR F L O W 18 - DOUBLE V BAND FOROUTER SHELLPART # DW14DWCLASY-2 Exhaust fan Vented curb per NFPA-96 Adjustable Duct Adjustable collar Fan adapter plate with ceramic gasket Standard duct Inner V-clamp Outer double V-clamp Insulated riser cover Riser Vertical support assembly. See installation manual for requirements. Insulated cleanouts to be provided in accordance with all state and local code requirements. Adjustable ducts are used on runs over 100ft to compensate for thermal expansion. See installation manual for requirements. Horizontal support assembly - see installation manual for requirements. HOOD Duct run shown is for example purposes only. See mechanical plans for additional information. See installation manual for minimum overlap requirements. Additional information including installation manual available at www.captiveaire.com. DOUBLE WALL GREASE DUCT WRITTEN SPECIFICATION SHELL OD SHELL OD+ .462" 8 8 COMBUSTIBLE SURFACE DUCT DOUBLE V-BAND 3/4" REDUCED CLEARANCE FOR TEMPERATURE SENSOR (IF APPLICABLE) MAXIMUM SPACING (FT) VERTICAL SUPPORT MAXIMUM SPACING (FT) DUCT DIAMETER 20" 18" 24" 10' 10' 10' 12" 14" 16" 8" 10" 10' 10' 10' 10' 10' LISTED GREASE DUCT. EXHAUST FAN. § HIGH TEMP GASKET IS USED TO SEAL THE FAN TO THE TRANSITION PLATE. VENTED CURB ROOF TERMINATION. THE INNER DUCT IS FULLY WELDED TO THE TRANSITION PLATE, ALL WELDS ARE DYE TESTED. SECURED TO THE CURB BY OTHER. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No. 9 6 BU I L T NF P A WIT H IN SLI D TE R 5700997 MASTER DRAWING asw-81 Pa r i s B a g u e t t e - A r c a d i a , C A 17 L a s T u n a s D r i v e , Lo s A n g e l e s O f f i c e 18 1 0 1 4 t h S t S u i t e 2 1 4 , S a n t a M o n i c a , C A , 9 0 4 0 4 P H O N E : ( 3 1 0 ) 8 7 6 - 8 5 0 5 F A X : ( 9 1 9 ) 7 4 7 - 5 6 3 9 E M A I L : r e g 8 1 @ c a p t i v e a i r e . c o m Ar c a d i a , C A , 9 1 0 0 7 I N T E R I O R D E S I G N M-6 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m HO O D I N F O R M A T I O N DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 - VARIABLE SPEED CONTROL. - THERMAL OVERLOAD PROTECTION (SINGLE PHASE). - HIGH HEAT OPERATION 300°F (149°C). EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. NORMAL TEMPERATURE TEST 22 1/2" 24 3/4" 31 7/8" 14 7/8" 2" 23" - INTERNAL WIRING. - ROOF MOUNTED FANS. - RESTAURANT MODEL. FEATURES: - DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS). 31 7/8" 24 3/4" - NEMA 3R SAFETY DISCONNECT SWITCH. 30 1/2" GREASE DRAIN. - GREASE CLASSIFICATION TESTING. - UL705 AND UL762 AND ULC-S645 ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600°F (316°C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. 3" FLANGE. 22 1/2" 22 1/2" ROOF OPENING DIMENSIONS. 20 GAUGE CONSTRUCTION. STEEL 20" 23" 23" VENTED CURB. EXAMPLE: 7/12 PITCH = 30° SLOPE. PITCHED CURBS ARE AVAILABLE FOR PITCHED ROOFS. SPECIFY PITCH: 0" 0° 12" FAN #1 DU85HFA - EXHAUST FAN (EF-1) OPTIONS - GREASE BOX. - FAN BASE CERAMIC SEAL - INSTALLED AT PLANT - FOR GREASE DUCTS. - 2 YEAR PARTS WARRANTY. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Label Description Location MT-01 Fan Motor [3] SW-01 Main disconnect switch [3] Component Identification 23 Installed Options RD - RED BL - BLUE WH - WHITE OR - ORANGE BR - BROWN BK - BLACK PK - PINKPR - PURPLE GY - GRAY GR - GREEN YW - YELLOW WIRE COLOR DENOTES FIELD WIRINGDENOTES INTERNAL WIRING NOTES SW-01 BK BK MT-01 GR BK GR BK BK BK 5 6 3 4 1 2 GR EXHAUST 0.75HP-208V-3P-2.6FLAVFD PART: ESV751N02YXB571 MOTOR INFO ELECTRICAL INFORMATIONMOTOR/CTRL MCA: 3.3AMOTOR/CTRL MOP: 15A DRAWING NUMBER JOB MODELSHIP DATEEXH5700997-1 5700997 - Paris Baguette - Arcadia, CA 10/25/2022 (LEFT) PLATE FAN BASE CURB FAN PLATE (LEFT) GREASE BOX (OPTIONAL) GREASE PIPE (OPTIONAL) CURB "A" DETAIL FAN COMPLETE SWING. FAN BASE ATTENTION: INSTALLER SHOULD SUPPLYENOUGH ELECTRICAL CORD TO LET FAN MAKE GREASE PIPE CURB ATTACH GREASE BOX COVER TO THE CURB 3" BELOW USING (3) LONG (3/4" LG.) SCREWS AS SHOWN. TOP EDGE OF CURB. INSTALL GREASE PIPE AS SHOWN. GREASE BOX SEPARATOR GREASE BOX COVER SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NFP A WIT H IN SLI D TE R 5700997 MASTER DRAWING asw-81 Pa r i s B a g u e t t e - A r c a d i a , C A 17 L a s T u n a s D r i v e , Lo s A n g e l e s O f f i c e 18 1 0 1 4 t h S t S u i t e 2 1 4 , S a n t a M o n i c a , C A , 9 0 4 0 4 P H O N E : ( 3 1 0 ) 8 7 6 - 8 5 0 5 F A X : ( 9 1 9 ) 7 4 7 - 5 6 3 9 E M A I L : r e g 8 1 @ c a p t i v e a i r e . c o m Ar c a d i a , C A , 9 1 0 0 7 I N T E R I O R D E S I G N M-7 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m HO O D I N F O R M A T I O N DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m BU I L T IN 5700997 MASTER DRAWING asw-81 Pa r i s B a g u e t t e - A r c a d i a , C A 17 L a s T u n a s D r i v e , Lo s A n g e l e s O f f i c e 18 1 0 1 4 t h S t S u i t e 2 1 4 , S a n t a M o n i c a , C A , 9 0 4 0 4 P H O N E : ( 3 1 0 ) 8 7 6 - 8 5 0 5 F A X : ( 9 1 9 ) 7 4 7 - 5 6 3 9 E M A I L : r e g 8 1 @ c a p t i v e a i r e . c o m Ar c a d i a , C A , 9 1 0 0 7 FLEX CONDUIT FOR FIELD WIRING. 13 1/4" 11 1/2" BLOWER DISCHARGE. CURB. 1 3/4" 3 7/8" 3 3/4" LIFTING LUG. AIRFLOW. BLOWER/MOTOR ACCESS DOOR 24" SERVICE CLEARANCE REQ. SERVICE DISCONNECT SWITCH. AIRFLOW. 18" 16" Ø1 1/2" WATER DRAIN. AIRFLOW. Ø1/2" NPT WATER INLET WATER FILTER REQUIRED PROVIDED BY PLUMBER. FILTER/CONTROL ACCESS DOOR. LPD CELDEK AIRFLOW. 27 3/8" 8 1/4" 21" 12" EQUIPMENT CURB. 32 1/8" 29 3/4" 21" 32 1/8" 36 3/4" 36 3/4" ADJUSTABLE LEG. 64 1/4" 117 7/8" MIN. 14" MINIMUM STRAIGHT DUCT PER AMCA* FAN #2 A1-15D - SUPPLY FAN (KMUA-1) 1. UNTEMPERED SUPPLY UNIT WITH 15" MIXED FLOW DIRECT DRIVE FAN IN SIZE #1 HOUSING. 2. EVAP COOLER (LPD CELDEK) – W/INTAKE HOOD W/EZ FILTERS. 3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT. 4. 120V WIRING CONNECTION TO ENERGIZE EVAPORATIVE COOLERS FROM UNTEMPERED SUPPLY FANS. 5. SEPARATE 120VAC WIRING PACKAGE FOR MAKE-UP AIR UNITS. OPTION MUST BE SELECTED WHEN MOUNTING VFD IN PREWIRE PANEL OR WITH DCV PACKAGE. PROVIDES SEPARATE 120VAC INPUT TO SUPPLY FAN. THIS 120V SIGNAL MUST BE RUN BY ELECTRICIAN FROM DCV TO MUA SWITCH. 6. HINGED DOUBLE WALL INSULATED DOOR ASSEMBLY (BURNER/BLOWER/EVAP SECTION). 7. 2 YEAR PARTS WARRANTY *NOTE: SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS. A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED DOWNSTREAM OF UNIT DISCHARGE AS OUTLINED IN AMCA PUBLICATION 201. WHEN USING RECTANGULAR DUCTWORK, ELBOWS MUST BE RADIUS THROAT, RADIUS BACK WITH TURNING VANES. FLEXIBLE DUCTWORK AND SQUARE THROAT/SQUARE BACK ELBOWS SHOULD NOT BE USED. ANY TRANSITION AND/OR TURNS IN THE DUCTWORK WILL CAUSE SYSTEM EFFECT. SYSTEM EFFECT WILL DRASTICALLY INCREASE STATIC PRESSURE AND REDUCE AIRFLOW. DO NOT RELY ON UNIT TO SUPPORT DUCT IN ANY WAY. FAILURE TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT. SUGGESTED STRAIGHT DUCT SIZE IS 14" x 14". L ETS DI R ROOF OPENING 2" SMALLER THAN CURB DIMENSION. 5" 5" 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 WIRE COLOR BK - BLACKBL - BLUEBR - BROWNOR - ORANGERD - REDWH - WHITE YW - YELLOW GR - GREEN NOTES DENOTES FIELD WIRING DENOTES INTERNAL WIRING GY - GRAY Label Description Location Component Identification 23 PR - PURPLEPK - PINK Installed Options SW-01R W B GR VA-01 11 BK BL N WH 11 BK [BK][WH] N WH Spray Timer Overflow Switch Thermostat Internal Solenoid Valve SW-02 SW-01 VA-01TI-01 [5-7] [6] [2] [5] GR D CSW-02NC TI-01 A1 A2TORBK WH N TI-01 1815 SV BL BR OR PRESSURE OVERFLOWSWITCH To buildingdrain Field Wiredand Piped From buildingwater supplyNormally closed valve B W Roof line R WB R SWITCH AE Normally open valve InternalWaterSolenoid TIMER 15 A1 18 A2 16 P If cable is CM1NO2VL2BO2 NOTE: change BK->BR & WH->BL JUMPER A1 AND B1 FOR RZ7-FSH3VU23 TIMER JUMPER A1 AND B1FOR TIMERRZ7-FSH3VU23 DRAWING NUMBER JOB MODELSHIP DATE- Paris Baguette 12/29/2021 SW-01 BK BK MT-01 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 GR BK GR Label Description Location MT-01 Supply motor [2] SW-01 Main disconnect switch [2] Component Identification 23 BK BK BK Installed Options Cooling Interlock BL WH N 11 RD - RED BL - BLUE WH - WHITE OR - ORANGE BR - BROWN BK - BLACK PK - PINK PR - PURPLE GY - GRAY GR - GREEN YW - YELLOW WIRE COLOR DENOTES INTERNAL WIRING DENOTES FIELD WIRING NOTES 7 8RD(DCV SF1)WH (DCV N1) DCV/VFD Wiring (MAY NOT BE NEEDED DEPENDING ON OPTIONS)IF DCV IS NOT PRESENT, RD AND WH WIRES FROM SEPARATE 120VAC SOURCE MOCP = 10 AMPS FOR CONTROL WIRING DROP FOR DISCONNECT CONNECTION !ATTENTION ELECTRICIAN! CONNECT POWER TO THE DROP 1 2 5 6 3 4 IS FACTORY SUPPLIED 11 N SUPPLY 1HP-208V-3P-3.1FLA MOTOR INFO ELECTRICAL INFORMATIONMOTOR CIRCUIT MCA: 3.9ACONTROL CIRCUIT MCA: 1.0AMOTOR CIRCUIT MOP: 15ACONTROL CIRCUIT MOP: 15A DRAWING NUMBER JOB MODELSHIP DATE Paris Baguette 12/29/2021 I N T E R I O R D E S I G N M-8 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m HO O D I N F O R M A T I O N DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 I N T E R I O R D E S I G N M-9 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m T- 2 4 F O R M S DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 I N T E R I O R D E S I G N M-10 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m T- 2 4 F O R M S DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 I N T E R I O R D E S I G N P-1 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m LE G E N D A N D G E N E R A L DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T 19. ALL PIPING INTO STEM WALLS AND FOOTINGS SHALL BE DOUBLE HALF LAP WRAPPED WITH 1/8" THICK "ARMOFLEX" INSULATION. THE CONTRACTOR SHALL ALSO PROVIDE BLOCKED OUT AREAS IN STEM WALL AND FOOTING. OTHER ON SITE PIPING AND EQUIPMENT BY CIVIL AND ELECTRICAL. 20. COORDINATE EXACT LOCATION OF ALL SITE PIPING INDICATED WITH ALL SHALL BE PROVIDED BY THE CONTRACTOR AND KEPT ON THE JOB SITE. 22. WHERE BRACING DETAILS ARE NOT SHOWN ON THE DRAWINGS OR IN THE 23. A COPY OF THE GUIDELINES PUBLISHED BY SMACNA GUIDELINES, THE FIELD INSTALLATION SHALL BE SUBJECT TO THE APPROVAL OF THE DESIGNER & ENGINEER OF RECORD 21. ALL BRACING OF PIPING SHALL BE INSTALLED IN ACCORDANCE WITH SMACNA GUIDELINES WITH MATERIALS TO MATCH EXISTING BY THE CONTRACTOR. ALL PIPING SHALL AVOID THE LOWER 8" OF THE FOOTING. 6. ALL CLEANOUTS SHALL BE INSTALLED WHERE EASILY ACCESSIBLE. THE EQUIPMENT, CABINETS, ETC., AND THE ARCHITECT PRIOR TO ANY 7. ALL PLUMBING FIXTURE VENTS TO TERMINATE A MIN. OF 12 INCHES 9. UNIONS SHALL BE PROVIDED AND INSTALLED AFTER EACH VALVE AND FROM ANY VERTICAL SURFACE AND 10 FEET FROM ANY OUTSIDE AIR EXACT LOCATIONS OF ALL MECHANICAL EQUIPMENT AND EQUIPMENT LOCATIONS AND REQUIREMENTS SHALL BE COORDINATED IN THE FIELD. 12. ALL CONNECTIONS TO SITE PIPING SHALL BE DONE BY THE PLUMBING 13. ALL WASTE AND VENT PIPING SHALL SLOPE AT 2% UNLESS OTHERWISE 11. BEFORE FABRICATION OR INSTALLATION THIS CONTRACTOR SHALL VERIFY PROVIDED UNDER ANOTHER SECTION OF SPECIFICATIONS. EXACT ROUGH-IN 8. ALL VALVES, UNIONS, ETC. TO BE SAME SIZE AS PIPE UNLESS INDICATED CONTRACTOR SHALL COORDINATE ALL CLEANOUT LOCATIONS WITH ALL SYSTEM NO. W1001. SEE ARCHITECTURAL PLANS FOR ALL WALL LOCATIONS. 17. PIPING THROUGH FIRE RATED WALLS SHALL BE PER U.L. FIRE RESISTANCE 14. ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTERS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVE NON-ACCESSIBLE CEILINGS 15. ALL PLUMBING FIXTURES AND EQUIPMENT SHALL BE CERTIFIED BY THE CALIFORNIA STATE ENERGY COMMISSION TO COMPLY WITH EFFICIENCY STANDARDS PER SECTION 2-5314(A) OF THE TITLE-24 REGULATIONS. 16. ALL HOT WATER PIPING SHALL BE INSULATED TO A MINIMUM THERMAL 18. ALL EXISTING PIPING DAMAGED DURING EXCAVATION SHALL BE REPAIRED INDICATED ON THE PLANS. RESISTANCE VALUE OF R-6 OR GREATER. CONTRACTOR. INDICATED ON DRAWINGS. AND PRIOR TO ALL EQUIPMENT CONNECTIONS. INSTALLATION. INTAKES. FLUSHING LEVERS SHALL BE TO THE WIDE SIDE OF THE STALL. AND PIPING, AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY 2. EXACT LOCATIONS AND MOUNTING HEIGHTS OF ALL PLUMBING FIXTURES WALL WITH ALL REQUIRED OFFSETS HAPPENING WITHIN THE WALL. ENCE WITH ELECTRICAL AND MECHANICAL EQUIPMENT AND STRUCTURAL MOUNTING HEIGHTS. FURNISH ALL EXPOSED HOT AND COLD WATER AND PRE-WRAPPED TAILPIECES AND P-TRAPS. ALL ACCESSIBLE WATER CLOSET 1. BEFORE COMMENCEMENT OF WORK, THE CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS, ELEVATIONS AND CHARACTERISTICS OF ALL UTILITIES 4. TRAPS FOR ALL LAVATORIES AND SINKS SHALL TRAP STRAIGHT BACK TO 5. ALL PLUMBING WORK SHALL BE INSTALLED SO AS TO AVOID INTERFER- 3. SEE ARCHITECTURAL DRAWINGS FOR ACCESSIBLE FIXTURE LOCATIONS AND DRAIN PIPING BELOW ALL LAVATORIES AND SINKS WITH McGUIRE PROWRAP SHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS. DISCREPANCIES OR PROBLEMS. FRAMING. 24. THE PLUMBING CONTRACTOR SHALL PROVIDE THE WATER, SEWER AND STORM DRAIN SYSTEMS TO A POINT OF CONNECTION 5'-0" OUTSIDE OF BUILDING AND SHALL CONNECT AT THE INVERT ELEVATION SHOWN ON THE CIVIL DRAWINGS. PIPING BEYOND THIS POINT IS SPECIFIED UNDER ANOTHER SECTION OF THE SPECIFICATION AND SHALL BE AS SHOWN ON THE CIVIL DRAWINGS. 25. ALL UNDERGROUND IRON, COPPER OR STEEL PIPING LOCATED BOTH INSIDE AND OUTSIDE OF BUILDING SHALL BE ENCASED WITHIN A MINIMUM 10 MIL POLYETHYLENE PLASTIC SLEEVE SEALED WATER TIGHT WITH POLYVINYL CHLORIDE TAPE. 26. ALL POINTS OF CONNECTION SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR PRIOR TO BID. WHENEVER POSSIBLE. COLUMN LOCATIONS, PIPING ROUGH-IN SHALL BE STUBBED IN WALLS 6" ABOVE THE FLOOR TO PROVIDE CLEARANCE FOR CLEANING. AT WALL OR SHALL BE RUN AT THE HIGHEST POSSIBLE ELEVATIONS AND NOT LESS THAN 29. ALL HORIZONTAL PIPING LINES EXTENDED AND CONNECTED TO EQUIPMENT 27. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH AND BE CONSIDERED TO BE A PART OF SEPARATE AND COMPLETE MECHANICAL SPECIFICATIONS. DESIGNATED BY THE OWNER'S REPRESENTATIVE. INTERRUPTION AND THE ACTUAL SHUT DOWN TIME SHALL BE AT A TIME SHALL GIVE THE OWNER'S REPRESENTATIVE SUFFICIENT NOTICE OF SUCH INTERRUPTION TIME WILL BE AS SHORT AS POSSIBLE. THE CONTRACTOR 28. ALL CONNECTIONS TO EXISTING SERVICES SHALL BE MADE SUCH THAT 30. ALL CUTTING OF EXISTING PAVINGS, WALKS AND/OR FLOORS SHALL BE BY MACHINE SAW CUTTING. HOLES FOR PIPES IN CONCRETE WALLS OR FLOORS SHALL BE DONE BY CORE DRILLING EQUIPMENT. YB CFH CUBIC FEET PER HOUR YARD BOX (E)V (E)HW (E)W SOV IN YB (E)CW S OR W S OR W DN BEL ABV W/ CLG FLR CONN I.E. AP POC VTR COTG GC CV SOV COYB WCO G (E)G G FCO HW CD EV CW CD V DOWN BELOW ABOVE WITH CEILING FLOOR VENT THRU ROOF POINT OF CONNECTION CONNECTION INVERT ELEVATION ACCESS PANEL CLEANOUT TO GRADE WALL CLEANOUT CLEANOUT IN YARDBOX SHUT-OFF VALVE IN YARD BOX CHECK VALVE SHUT-OFF VALVE GAS COCK EXISTING HOT WATER EXISTING COLD WATER GAS (LOW PRESSURE) EXISTING GAS HOT WATER FLOOR CLEANOUT EXISTING SANITARY VENT EXISTING SOIL OR WASTE SANITARY VENT COLD WATER CONDENSATE DRAIN SOIL OR WASTE (BELOW GRADE) SOIL OR WASTE (ABOVE GRADE) ABOVE GROUND PIPING SYSTEMS SHALL BE MARKED IN ACCORDANCE WITH ASME A13.1. 31. CAP AND ABANDON ALL EXISTING WASTE PIPING BELOW FLOOR EXCEPT INDICATED TO BE REUSED. ROUTER AND CLEAN ALL EXISTING WASTE PIPING TO BE REUSED. EXISTING PIPING ABOVE CEILING AND IN EXISTING WALLS BEING DEMOLISHED, THAT IS NOT BEING REUSED, SHALL BE REMOVED. COORDINATE EXTENT OF DEMOLITION WITH THE ARCHITECT AND THE GENERAL CONTRACTOR. THE CONTRACTOR SHALL VERIFY THE EXACT DEPTH AND LOCATION OF EXISTING DRAINAGE SYSTEM LATERALS PRIOR TO INSTALLATION OF ANY PIPING. ALL FIXTURES, EQUIPMENT, PIPING AND MATERIAL SHALL BE LISTED. ALL PLUMBING FIXTURES SHALL MEET THE FLOW REQUIREMENTS SPECIFIED IN THE CITY OF ARCADIA PLUMBING CODE. ALL FAUCETS IN PUBLIC RESTROOMS SHALL BE SELF CLOSING OR SELF CLOSING METERING. PUBLIC LAVATORIES SHALL HAVE CONTROLS TO LIMIT THE WATER TEMPERATURE TO 110F WATER PIPING AND FITTINGS WITH LEAD CONTENT WHICH EXCEED 0.25% SHALL BE PROHIBITED IN SYSTEMS CONVEYING POTABLE WATER. 32. 33. 34. 10.ALL WORK SHALL BE PERFORMED AND ALL MATERIALS SHALL BE INSTALLED IN COMPLIANCE WITH THE FOLLOWING CODES AS ADOPTED AND AMENDED BY THE INSPECTING AUTHORITY. NOTHING IN THESE DRAWINGS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES OR OTHERS APPLICABLE TO THIS PROJECT: PRE-CONSTRUCTION MEETING IS REQUIRED BY INSPECTION. TO SCHEDULE MEETING, CALL INSPECTIONS SUPERVISOR 1. 2.ALL PIPE, FITTINGS, FIXTURES, ETC THAT CONTACT PORTABLE WATER FOR HUMAN CONSUMPTION SHALL SHOW APPROVAL TO NSF 61, ANNEX G. REFERENCE SECTION 604.10, CALIFORNIA PLUMBING CODE, 2019 EDITION AND HEALTH AND SAFETY CODE SECTION 116875. 3.EQUIPMENT ON CASTERS SHALL BE INSTALLED IN ACCORDANCE WITH THEIR LISTING AND THE ACCOMPANYING MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR LIMITING THE MOVEMENT OF THE EQUIPMENT TO PREVENT STRAIN ON THE (FUEL) CONNECTION. SECTION 913.6, 2019 CPC. ALL PLUMBING FIXTURES ON PLUMBING FIXTURE AND EQUIPMENT SCHEDULE MEET THE REQUIREMENTS OF CALIFORNIA GREEN CODE, INCLUDING ITEMS NOTED IN CHAPTER 5, DIVISION 5.3 ; WATER EFFICIENCY AND CONSERVATION: WATER REDUCTION 5.303.2.2 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS 5.303.3 WATER CLOSETS 5.303.3.1 URINALS 5.303.3.2 WASTEWATER REDUCTION 5.303.4 STANDARDS FOR PLUMBING FIXTURES AND FITTINGS 5.303.6 .CPC CHAPTER 14 35. 36. 37. 38. 39. FLUID TEMPERATURE RANGE (°F) ABOVE 350 SPACE HEATING, HOT WATER (STEAM, STEAM CONDENSATE & HOT WATER) AND SERVICE WATER HEATING SYSTEMS 251 - 350 141 - 200 105 - 140 CONDUCTIVITY RANGE (IN BTU-INCH PER HOUR PER SQUARE FOOT PER °F) INSULATION MEAN RATING TEMPERATURE (°F) NOMINAL PIPE DIAMETER (IN INCHES) INSULATION THICKNESS REQUIRED (IN INCHES) <1 1 TO <1.5 TO <4 1.5 TO <8 41 8 AND LARGER TO 0.32 - 0.34 0.29 - 0.31 0.27 - 0.30 0.25 - 0.29 0.22 - 0.28 250 200 150 125 100 4.5 3.0 2.5 1.5 1.0 5.0 4.0 2.5 1.5 1.5 5.0 4.5 2.5 2.0 1.5 5.0 4.5 3.0 2.0 1.5 5.0 4.5 3.0 2.0 1.5 SPACE COOLING SYSTEMS (CHILLED WATER, HVAC SYSTEMS, HVAC CONDENSATE, REFRIGERANT AND BRINE) 40 - 60 0.21 - 0.27 75 0.5 0.5 1.0 1.0 1.0 BELOW 40 0.20 - 0.26 50 1.0 1.5 1.5 1.5 1.5 201 - 250 TABLE 120.3-A PIPE INSULATION THICKNESS 1.CONTRACTOR TO PROVIDE COMPLETE SEISMIC ANCHORAGE AND BRACING FOR ALL MECHANICAL EQUIPMENT THAT IS DIRECTLY MOUNTED ON THE FLOOR OR ROOF AND ALL MECHANICAL EQUIPMENT THAT IS SUSPENDED FROM THE FLOOR, WALL OR SUPPORTED BY VIBRATION ISOLATORS TO RESIST A HORIZONTAL FORCE ACTING IN ANY DIRECTION USING THE CRITERIA OUTLINED IN THE CALIFORNIA BUILDING CODE, REFER TO CHAPTER 16A. PROVIDE ANCHORAGE CALCULATIONS AND DETAILS CERTIFIED BY A STRUCTURAL ENGINEER REGISTERED IN THE STATE OF CALIFORNIA. THE INSTALLATION SHALL BE SUBJECT TO THE APPROVAL OF THE STRUCTURAL ENGINEER AND WITH ALL APPLICABLE AMENDMENTS AND FIRE DEPARTMENTS. 2.CONTRACTOR TO PROVIDE COMPLETE SEISMIC BRACING AND ANCHORAGE OF ALL PIPING AND DUCTWORK. BRACING AND ANCHORAGE SHALL CONFORM TO MASON INDUSTRIES"SEISMIC RESTRAINT GUIDELINES FOR SUSPENDED PIPING, DUCTWORK AND ELECTRICAL SYSTEMS", I.S.A.T. OPA-0485 "ENGINEERED SEISMIC BRACING OF SUSPENDED UTILITIES", SMACNA "GUIDELINES FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS", OR OTHER PRE-APPROVED SYSTEMS. 3.ALL PIPING, DUCTWORK AND CONDUIT CROSSING BUILDING SEISMIC SEPARATIONS SHALL BE PROVIDED WITH APPROVED FLEXIBLE CONNECTORS. AMERICAN STANDARD "LUCERNE" NO. 355.012 WALL MOUNTED LAVATORY FAUCET CHICAGO NO. 844-665PSHCP, GRID STRAINER DRAIN, OFFSET TAILPIECE, LA PATTERN P TRAP, LOOSE KEY ANGLE STOPP 1 4 TURN. PROVIDE TRUEBRO "HANDI LAV-GUARD #102 KIT. BRADLEY POINT OF USE MIXING VALVE S59-4000 ADVANCE-TABCO WALL MOUNTED SERVICE SINK MODEL FC-WM-2219-F WITH FAUCET AMERICAN STANDARD FAUCET 8350.243 WITH INTEGRAL VACUUM BREAKER. PROVIDE GRID STRAINER AND 3" TRAP AMERICAN STANDARD "CADET" MODEL 2403.128 ELONGATED BOWL, VITREOUS CHINA, 1.28 GPF, WITH VACUUNM BREAKER, TOILET SEAT OLSONITE NO. 95 OPEN FRONT. NO T E S 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 I N T E R I O R D E S I G N P-1.1 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m KI T C H E N E Q U I P M E N T P L A N DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T SYMBOL SERVICE LOCATION KITCHEN AREA MANUFACTURER & MODEL NO. (2)NORITZ MODEL NCC199 INPUT BTU/HR 199,000 GAS TYPE NATURAL EWT DG °F 60 140 LWT DG °F GPM RECOVERY @ 80 TEMP RISE 4.8 VENT DIAMETER 4"70 OPERATING WEIGHT (LBS) LOW NOX. INSTANTANEOYS WATER HEATER, 115V, 1Ø, 60HZ., 2 AMPS. PROVIDE CONDENSATE NEUTRALIZER, CONTROLLER. REMARKS SERVICES LOCATION DOMESTIC COLD & HOT WATER UNDERGROUND ABOVE GROUND MATERIAL RIGID COPPER (TYPE K) JOINING METHOD REMARKS RIGID COPPER (TYPE L) SANITARY WASTE SEWER UNDERGROUND ABOVE GROUND SANITARY WASTE VENT ABOVE GROUND & BELOW GROUND CAST IRON SOIL PIPE & FITTINGS OR LOW PRESSURE GAS UNDERGROUND ABOVE GROUND SCHEDULE 40 BLACK STEEL WRAPPED 10MIL SCHEDULE 40 BLACK STEEL STORM DRAIN UNDERGROUND ABOVE GROUND CAST IRON SOIL PIPE CAST IRON SOIL PIPE ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019 313.0 AND 313.10. ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019 313.0 AND 313.10. ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019 313.0 AND 313.10. ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019 313.0 AND 313.10. ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019 313.0 AND 313.10. ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019 313.0 AND 313.10. ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019 313.0 AND 313.10. ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019 313.0 AND 313.10. ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN COMPLIANCE WITH CPC 2019 313.0 AND 313.10. NOTE: ALL BRAZED AND SOLDERED JOINTS SHALL BE LEAD FREE. ABS PIPE SOLID WALL AND PVC PIPE AND FITTINGS CAN BE USED ONLY WHEN FIRST APPROVED BY AHJ. 1/6 1120 60 REMARKSHZØVHP MOTOR 2010-30 TDH HEADGPM CAPACITY AND MODEL NO. MANUFACTURER SERVICESYMBOLLOCATION BELL AND GOSSETT ALL BRONZE CONSTRUCTION SERVEDSYMBOLAREA LOCATION MANUFACTURER AND MODEL NO. MAXIMUM OPERATING PRESSURE PSI MAXIMUM ACCEPTANCE VOLUME(GAL.) DIAMETER/ HEIGHT (INCHES) OPERATING WEIGHT (LBS.) WATER HEATER AMTROL THERM-X- TROL ST-12 3.2 11"X 15"40 - REMARKS KITCHEN KITCHEN HOT WATER RETURN 150 DOMESTIC HOT WATER GREASE INTERCEPTOR SCHEDULE ITEM HOT WATER -----GI 1 -- VENTWASTE 2"4"-- ROUGH-IN CONNECTIONSFIXTURE DESCRIPTION TRAP COLD WATER GAS CFH DESCRIPTION JENSEN GREASE INTERCEPTOR MODEL JP750G, 750 GALLON TANK, WITH SAMPLING BOX, TRAFFIC RATED, PROVIDE ADJUSTING RINGS, C.I. MANHOLE COVERS, VENT. GREASE INTERCEPTOR 2019 CPC TABLE 1215.2(1) NFPA 54 TABLE 6.2(b) MAXIMUM DELIVERY CAPACITY OF SCHEDULE 40 METALLIC PIPE CARRYING NATURAL GAS OF 0.60 SPECIFIC GRAVITY BASED ON A PRESSURE DROP OF 0.5" WATER COLUMN, GAS PRESSURE 8" WC PIPE SIZE IN INCHES NOMINAL ID 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 LENGTH (FT)CAPACITY IN CUBIC FEET OF GAS PER HOUR 10 172 360 678 1,390 2,090 4,020 6,400 11,300 20 118 247 466 957 1,430 2,760 4,400 7,780 30 95 199 374 768 1,150 2,220 3,530 6,250 40 81 170 320 657 985 1,900 3,020 5,350 50 72 151 284 583 873 1,680 2,680 4,740 60 65 137 257 528 791 1,520 2,430 4,290 70 60 126 237 486 728 1,400 2,230 3,950 80 56 117 220 452 677 1,300 2,080 3,670 90 52 110 207 424 635 1,220 1,950 3,450 100 50 104 195 400 600 1,160 1,840 3,260 125 44 92 173 355 532 1,020 1,630 2,890 150 40 83 157 322 482 928 1,480 2,610 1.ALL GAS PIPING DOWNSTREAM OF PRESSURE REGULATOR TO BE SIZED PER CPC TABLE 1216.2(1) 2.GAS METERS TO BE ACCESSIBLE. INSTALL AUTOMATIC EARTHQUAKE SHUT-OFF VALVE & REGULATOR AS REQUIRED. 3.GAS SHUT-OFF VALVES & PRESSURE REGULATORS TO BE EASILY ACCESSIBLE. 4.GAS METER LOCATIONS VARY. PLUMBING CONTRACTOR TO COORDINATE GAS PIPE ROUTING FROM GAS METERS TO ANY STEP-DOWN PRESSURE REGULATORS. 175 37 77 144 296 443 854 1,360 2,410 200 34 71 134 275 412 794 1,270 2,240 250 30 63 119 244 366 704 1,120 1,980 4 23,100 15,900 12,700 10,900 9,660 8,760 8,050 7,490 7,030 6,640 5,890 5,330 4,910 4,560 4,050 LOW PRESSURE NATURAL GAS PIPE SIZING TABLE SOLID WALL ABS PIPE AND FITTINGS CAST IRON SOIL PIPE & FITTINGS OR SOLID WALL ABS PIPE AND FITTINGS CAST IRON SOIL PIPE & FITTINGS OR SOLID WALL ABS PIPE AND FITTINGS 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 NSITE PLAN Scale: 1/8"=1'-0" PARIS BAGUETTE 7 LAS TUNAS DR.ARCADIA CA 91007 LA S T U N A S D R I V E EXISTING PARKING EXISTING PARKING EXISTING PARKING EXISTING PARKING EXISTING PARKING I N T E R I O R D E S I G N P-1.2 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m PL U M B I N G S I T E P L A N DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T (E) SAMPLING BOX DETAIL (E) GREASE INTERCEPTOR DETAIL 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 (N)F.S. (N)F.S. (N)F.S. (N)F.S. (N)F.S. (N)F.S. 01KITCHEN EQUIPMENT PLAN Scale: 1/4" = 1'-0" 1 AB 2 3 21A PATIO SEATING AREA (N)F.S. (N)F.S. (N)F.S. (N)F.S. (N)F.S. (N)F.S. 3'-0" 49VL5GLG CAKE STORAGE REFRIGERATOR 1 35600.0020BUNN1 CONVECTION OVEN 1 TUC-60TRUE1UNDERCOUNTER REFRIGERATOR 60" (TR) CAKE PREP FRIDGE 48"2 UD-0310A1MANITOWICUNDERCOUNTER ICE MACHINE COFFEE BREWER BUNN 53200.01011 TGM-22RV(B)-N6TURBO AIR UNDERCOUNTER REFRIGERATOR 60"TURBO AIR JUR-60S-N6 GRINDER DISPLAY CASE REFRIGERATED 60"1 TCGB-60UF-B-N DECK OVEN (3 DECK)1 PARIS CROISSANT SD-3 4TV 2POS TOAST TOAST FLEX 1STAINLESS STEEL WORK TABLE 48"WT-EB3048 1STAINLESS STEEL WORK TABLE 36" 5' CUTTING BOARD W/L CLIP 1 CUTTING BOARD 1DROP IN HAND SINK PREP. SINK 1 1B184-1D18R 3 COMPARTMENT SINK 1 60053242418G HS-1317 TURBO AIR NITRON COLD DRAFT SCHOLL COFFEE MACHINE 1 BUNN WRDG-51600.0020 1 2 3 5 6 7 8 10 11 12 13 14 15 16 17 18A 19 20 20A 21 22 23 24 25A 26 27 28 29 30 31 33 34 35 35A 36 37 38 39 40 41 42 43 1 PARIS CROISSANTDECK OVEN STAND BREAD RACK (TALL)1 PARIS CROISSANT CONVECTION OVEN (2 DECK)1 MOFFAT TURBOFAN 1 MOFF-E35D6-26/2CCONVECTION OVEN STAND MOFFAT TURBOFAN 3 TDC-30-2RNEW DOUGH CONDITIONER TURBO AIR GRAB AND GO BEVERAGE 1 TURBO AIR TOM-50-B-N 1 TCGB-48UF-B-NTURBO AIRDISPLAY CASE REFRIGERATED 48" SANDWICH PREPARATION REFRIGERATOR 1 MST-72-NTURBO AIR 1 THERMAL DISPENSER BUNN 42700.02002 BLENDER, BAR BLENDTEC S885C2901-B1GB1D2 DONUT FRYER CAKE MIXER KSM8990WH MICROWAVE OVEN (UNDERCOUNTER)NE-1025F BREAD SLICER ESPRESSO MACHINE 2PITCHER RINSER BLENDTEC RAPID RINSER EMPLOYEE LOCKER 2 HAND SINK JOHN BOOS PBHS-W-1410-P-SSLR2 44 16"x20"x12"CHEMICAL SHELVE & MOP RACK 27.9"X22"X23.6" 13.3"X14.6"X16.5"120V, 500W, 60HZ 20.25"X16.5"X12"NSF NSF 60 3/8"x30 1/8"x29 3/4"UL, NSF NSF, ETL8.6"X9"X17.3"120V/220V-, 3.8HP 208V-, 30APROVIDE WATER FILTER SYSTEMPROVIDE APPROVED BACKFLOW PREVENTER FLOOR SINKINDIRECT 59"X27 1/2"X28 3/4"ETL 2.5" CASTER 72 5/8"X30"X37"UL, NSF 5" CASTER 115V-, 5.7AMP, 2/5HP 120V-, 13.5AMP 2.5" CASTER 115V, 5.1A 1/5HP 13"X17 1/2"X6 3/8"NSF 1/2"1/2"DIRECT 112"X29.5"X43.75"NSF 1/2"1/2"DIRECT 6" LEG 1/2"1/2" PROVIDE APPROVED BACKFLOW PREVENTER ETL 48 1/2"X34 1/4"X50 1/8"NSF 115V- 7.5A, 1/3HP4" CASTER 28 3/4"X27 5/8"X79 7/8"115V, 2.2A 1/5HPETL4" CASTER 23.9"X26.8"X34.6"120V-, 7.3AMP 14"X10"X5"NSF 1/2"1/2"DIRECT 18"X18"X14"NSF 6" LEG PROVIDE APPROVED BACKFLOW PREVENTER FOLLOWING C.D INDIRECT FLOOR SINK1/2"1/2" DIRECTW/ 18" DRAIN BD. FOLLOWING C.D. NSF 1 1 3 1 KTCHNNAID PANASONIC TURBO CHEF ECO SPE-203-161825 MOFF-E35D6-26/2 THE ECO 65"x42"x21"5" CASTER 220V, 3PH, (3) 40AMPINDIRECTFLOOR SINKUL, NSF PROVIDE APPROVED BACKFLOW PREVENTER 1 1 JAC EVERSYS PICOMATIC E4 MOP SINK45 46B 46C WALL MOUNT SHELF 36"1836NK3-METROSEAL WALL MOUNT SHELF 36"1436NK3-METROSEAL 5 3 METRO SUPER ERECTA METRO SUPER ERECTA EAGLE F1916-12 & 312690 EL-5DR KROWNE JOHN BOOS REGENCY 1 54 55 STANDING SHELF (CHROME) 18" x 36" STANDING SHELF (CHROME) 18" x 48" 70 71 STANDING SHELF (GREEN) 18" x 48" STANDING SHELF (GREEN) 18" x 60" 2WALL MOUNT SHELF 24"METRO SUPER ERECTA 1824NK3-METROSEAL 86 86A 87 89 STAINLESS STEEL WALL-MOUNTED SHELF 6" x 36" STAINLESS STEEL WALL-MOUNTED SHELF 6" x 60" 1 1 12X721 90 91 91A 91B 91C WALL MOUNT SHELF 48" 1848NK3-METROSEAL WALL MOUNT SHELF 72" 18X72 WALL MOUNT SHELF 72" 1 2 METRO SUPER ERECTA 1 2 14X72 12X72 STAINLESS STEEL WALL-MOUNTED SHELF 6" x 48"1 7 4 5 4 WALL MOUNT SHELF 72" WALL MOUNT SHELF 72" NSF 4" CASTER26"X20 1/4"X68 5/8" 50 7/8"X28"X78 1/2"NSF 4" CASTER 115V- 15.5A, 3/4HP 30"X28 1/2"X44 1/2"UL, NSF 6" LEG 115V- 10APROVIDE APPROVED BACKFLOW PREVENTER INDIRECT FLOOR SINK WHOLE CAKE SHOWCASE, PB LED LIGHT SHORT CAKE SHOWCASE, PB LED LIGHT BACK LINE (FAN ON FRONT) KITCHEN (FAN ON BACK) PROVIDE WATER FILTER SYSTEM 5-TIER, 12"W x 20"D x 77"H FOLLOWING C.D. FOLLOWING C.D. FOLLOWING C.D. TUC-48-HC UL48 3/8"X30 1/8"X29 3/4"TRUE 115V-, 3AMP, 1/3HP5" CASTER 35 7/8"W x 77 1/2"H x 36 7/8"D NSF, ETL35 7/8"W x 77 1/2"H x 36 7/8"D 220-240V, 60Hz, 12.5kW 208V, 60Hz, 11.2kWNSF, ETL 220-240V, 60Hz, 12.5kW 208V, 60Hz, 11.2kW 31 1/2" x 48 3/4" x 77 7/8"ETL 115/60/1 601/2" X 34 1/4" X 50 1/8"NSF 115V- 7.5A, 1/3HP 20.2"W x 22.3"D x 35"H UL, NSF 120V/240V, 60 HERTZ 10"W x 28.4"D x 34"H NSF, ETL 120V, 60 HERTZ 120V, 60 HERTZ9.4"W x 18.6"D x 29.1"H NSF, ETL UL, ETL NSF9.3"W x 13"D x 20.7"H UL16.1"W x 23.5"D x 21.5"H 208/240 VAC, 60Hz, 20AMP 42.425"W x 3.531"D x 23.929"H High Mode: 10” x 14” x 8.6 Low Mode: 6.5” x 14” x 8.6”24 Volt NSF8.8"W x20.5"D x 7.5" H GSW USA GSW USA 30"W x 48"L x 35" H 30"W x 36"L x 35" HGSW USA WT-EB3036 NSF ETL NSF ETL 12"W x 20"D x 77" H 18"W x 36"L 14"W x 36"L NSF NSF 18"W x 24"L 18"W x 48"L NSF NSF METRO 4'-0"X1'-6"X6'-0"1848 BR 5 TIES - 18" DEPTHNSF6" LEG 1836 BR 3'-0"X1'-6"X6'-0"5 TIES - 18" DEPTH6" LEGNSFMETRO BLUEAIR 48"X12"WS1248 NSF BLUEAIR 36"X12"WS1236 NSF BLUEAIR 60"X12"WS1260 NSF METRO SUPER ERECTA METRO SUPER ERECTA METRO SUPER ERECTA METRO SUPER ERECTA METRO SUPER ERECTA PITCO 15-5/8"X35"X52"120V, 3PH, 0.5AMPETL6" LEG 44,000BTUBNB-SG14 REGENCY 4'-0"X1'-6"X6'-0"NSF 5 TIES - 18" DEPTH6" LEG REGENCY 5'-0"X1'-6"X6'-0"NSF 5 TIES - 18" DEPTH6" LEG DUMP SINK 1 NSF -DIRECT 1DIPPER WELL KROWNE 16-149 NSF7 3/16 X 6 3/16 NSFNSF INDIRECT (FLOOR MOUNTED) PROVIDE APPROVED BACKFLOW PREVENTER PROVIDE APPROVED BACKFLOW PREVENTER PROVIDE APPROVED BACKFLOW PREVENTER AIR CURTAIN MARS ETL 115V, 9A 1HPAIR VELOCITY MIN.1600FPM (PROVIDED 2389FPM),DOOR SWITCH ACTIVATED TYPE36 "X16"X14"NH-236-1U-TS192 (E)FIXED WINDOW TO REMAIN (E)FIXED WINDOW TO REMAIN (E ) F I X E D W I N D O W TO R E M A I N 01KITCHEN EQUIPMENT PLAN Scale: 1/4" = 1'-0" WATER HEATER 1 SEE PLUMBING DRAWING INDIRECT STANDING SHELF (GREEN) 18" x 36"2 REGENCY 3'-0"X1'-6"X6'-0"NSF 5 TIES - 18" DEPTH6" LEG SELF CLOSING HARDWARE HS-1317 13"X17 1/2"X6 3/8"KROWNE FOLLOWING C.D. 1/2"CW DOWN IN WALL TO FIXTURE ROUGH IN AND CONNECT 3/4"CW AND 3/4"HW IN WALL TO FIXTURES ROUGH IN AND CONNECT 1/2"CW AND 1/2"HW IN WALL TO FIXTURES ROUGH IN AND CONNECT 1 1/4"CW DOWN TO WATER AND 1 1/4"HW UP FROM WATER HEATER 1" GAS DOWN WITH LINE SIZE SHUT OFF VALVE TO WATER HEATER ROUGH IN AND CONNECT LINE SIZE AUTOMATIC SHUT OFF VALVE INTERLOCK WITH HOOD FIRE EXTINGUISHING SYSTEM 1/2"ICW UP THROUGH ROOF TO EVAP COOLER ROUGH IN AND CONNECT, PROVIDE LINE SIZE SHUT OFF VALVE PRIOR TO CONNECTION PROVIDE LINE ZONE OF REDUCED PRESSURE BACKFLOW PREVENTER WATTS LF909 FOR ICE MAKER 1 1/2" GAS FROM GAS METER FOR CONTINUATION SEE P-1.1 3/4" GAS LINE DOWN IN WALL TO EQUIPMENT CONNECT 1 1/2"CW TO EXISTING 2"CW IN CEILING FIELD VERIFY EXACT LOCATION 1/2"CW DOWN IN WALL TO EQUIPMENT PROVIDE LINE SIZE ZONE OF REDUCED PRESSURE BACKFLOW PREVENTER WATTS LF 909 EXTEND 3/4"CW AND 3/4"HW IN WALL TO FIXTURE AND EQUIPMENT I N T E R I O R D E S I G N P-2 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m GA S H O T A N D DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T CO L D W A T E R F L O O R P L A N 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 1 AB 2 3 21A PATIO SEATING AREA (N)F.S. (N)F.S. (N)F.S. (N)F.S. (N)F.S. (N)F.S. 3'-0" 49VL5GLG CAKE STORAGE REFRIGERATOR 1 35600.0020BUNN1 CONVECTION OVEN 1 TUC-60TRUE1UNDERCOUNTER REFRIGERATOR 60" (TR) CAKE PREP FRIDGE 48"2 UD-0310A1MANITOWICUNDERCOUNTER ICE MACHINE COFFEE BREWER BUNN 53200.01011 TGM-22RV(B)-N6TURBO AIR UNDERCOUNTER REFRIGERATOR 60"TURBO AIR JUR-60S-N6 GRINDER DISPLAY CASE REFRIGERATED 60"1 TCGB-60UF-B-N DECK OVEN (3 DECK)1 PARIS CROISSANT SD-3 4TV 2POS TOAST TOAST FLEX 1STAINLESS STEEL WORK TABLE 48"WT-EB3048 1STAINLESS STEEL WORK TABLE 36" 5' CUTTING BOARD W/L CLIP 1 CUTTING BOARD 1DROP IN HAND SINK PREP. SINK 1 1B184-1D18R 3 COMPARTMENT SINK 1 60053242418G HS-1317 TURBO AIR NITRON COLD DRAFT SCHOLL COFFEE MACHINE 1 BUNN WRDG-51600.0020 1 2 3 5 6 7 8 10 11 12 13 14 15 16 17 18A 19 20 20A 21 22 23 24 25A 26 27 28 29 30 31 33 34 35 35A 36 37 38 39 40 41 42 43 1 PARIS CROISSANTDECK OVEN STAND BREAD RACK (TALL)1 PARIS CROISSANT CONVECTION OVEN (2 DECK)1 MOFFAT TURBOFAN 1 MOFF-E35D6-26/2CCONVECTION OVEN STAND MOFFAT TURBOFAN 3 TDC-30-2RNEW DOUGH CONDITIONER TURBO AIR GRAB AND GO BEVERAGE 1 TURBO AIR TOM-50-B-N 1 TCGB-48UF-B-NTURBO AIRDISPLAY CASE REFRIGERATED 48" SANDWICH PREPARATION REFRIGERATOR 1 MST-72-NTURBO AIR 1 THERMAL DISPENSER BUNN 42700.02002 BLENDER, BAR BLENDTEC S885C2901-B1GB1D2 DONUT FRYER CAKE MIXER KSM8990WH MICROWAVE OVEN (UNDERCOUNTER)NE-1025F BREAD SLICER ESPRESSO MACHINE 2PITCHER RINSER BLENDTEC RAPID RINSER EMPLOYEE LOCKER 2 HAND SINK JOHN BOOS PBHS-W-1410-P-SSLR2 44 16"x20"x12"CHEMICAL SHELVE & MOP RACK 27.9"X22"X23.6" 13.3"X14.6"X16.5"120V, 500W, 60HZ 20.25"X16.5"X12"NSF NSF 60 3/8"x30 1/8"x29 3/4"UL, NSF NSF, ETL8.6"X9"X17.3"120V/220V-, 3.8HP 208V-, 30APROVIDE WATER FILTER SYSTEMPROVIDE APPROVED BACKFLOW PREVENTER FLOOR SINKINDIRECT 59"X27 1/2"X28 3/4"ETL 2.5" CASTER 72 5/8"X30"X37"UL, NSF 5" CASTER 115V-, 5.7AMP, 2/5HP 120V-, 13.5AMP 2.5" CASTER 115V, 5.1A 1/5HP 13"X17 1/2"X6 3/8"NSF 1/2"1/2"DIRECT 112"X29.5"X43.75"NSF 1/2"1/2"DIRECT 6" LEG 1/2"1/2" PROVIDE APPROVED BACKFLOW PREVENTER ETL 48 1/2"X34 1/4"X50 1/8"NSF 115V- 7.5A, 1/3HP4" CASTER 28 3/4"X27 5/8"X79 7/8"115V, 2.2A 1/5HPETL4" CASTER 23.9"X26.8"X34.6"120V-, 7.3AMP 14"X10"X5"NSF 1/2"1/2"DIRECT 18"X18"X14"NSF 6" LEG PROVIDE APPROVED BACKFLOW PREVENTER FOLLOWING C.D INDIRECT FLOOR SINK1/2"1/2" DIRECTW/ 18" DRAIN BD. FOLLOWING C.D. NSF 1 1 3 1 KTCHNNAID PANASONIC TURBO CHEF ECO SPE-203-161825 MOFF-E35D6-26/2 THE ECO 65"x42"x21"5" CASTER 220V, 3PH, (3) 40AMPINDIRECTFLOOR SINKUL, NSF PROVIDE APPROVED BACKFLOW PREVENTER 1 1 JAC EVERSYS PICOMATIC E4 MOP SINK45 46B 46C WALL MOUNT SHELF 36"1836NK3-METROSEAL WALL MOUNT SHELF 36"1436NK3-METROSEAL 5 3 METRO SUPER ERECTA METRO SUPER ERECTA EAGLE F1916-12 & 312690 EL-5DR KROWNE JOHN BOOS REGENCY 1 54 55 STANDING SHELF (CHROME) 18" x 36" STANDING SHELF (CHROME) 18" x 48" 70 71 STANDING SHELF (GREEN) 18" x 48" STANDING SHELF (GREEN) 18" x 60" 2WALL MOUNT SHELF 24"METRO SUPER ERECTA 1824NK3-METROSEAL 86 86A 87 89 STAINLESS STEEL WALL-MOUNTED SHELF 6" x 36" STAINLESS STEEL WALL-MOUNTED SHELF 6" x 60" 1 1 12X721 90 91 91A 91B 91C WALL MOUNT SHELF 48" 1848NK3-METROSEAL WALL MOUNT SHELF 72" 18X72 WALL MOUNT SHELF 72" 1 2 METRO SUPER ERECTA 1 2 14X72 12X72 STAINLESS STEEL WALL-MOUNTED SHELF 6" x 48"1 7 4 5 4 WALL MOUNT SHELF 72" WALL MOUNT SHELF 72" NSF 4" CASTER26"X20 1/4"X68 5/8" 50 7/8"X28"X78 1/2"NSF 4" CASTER 115V- 15.5A, 3/4HP 30"X28 1/2"X44 1/2"UL, NSF 6" LEG 115V- 10APROVIDE APPROVED BACKFLOW PREVENTER INDIRECT FLOOR SINK WHOLE CAKE SHOWCASE, PB LED LIGHT SHORT CAKE SHOWCASE, PB LED LIGHT BACK LINE (FAN ON FRONT) KITCHEN (FAN ON BACK) PROVIDE WATER FILTER SYSTEM 5-TIER, 12"W x 20"D x 77"H FOLLOWING C.D. FOLLOWING C.D. FOLLOWING C.D. TUC-48-HC UL48 3/8"X30 1/8"X29 3/4"TRUE 115V-, 3AMP, 1/3HP5" CASTER 35 7/8"W x 77 1/2"H x 36 7/8"D NSF, ETL35 7/8"W x 77 1/2"H x 36 7/8"D 220-240V, 60Hz, 12.5kW 208V, 60Hz, 11.2kWNSF, ETL 220-240V, 60Hz, 12.5kW 208V, 60Hz, 11.2kW 31 1/2" x 48 3/4" x 77 7/8"ETL 115/60/1 601/2" X 34 1/4" X 50 1/8"NSF 115V- 7.5A, 1/3HP 20.2"W x 22.3"D x 35"H UL, NSF 120V/240V, 60 HERTZ 10"W x 28.4"D x 34"H NSF, ETL 120V, 60 HERTZ 120V, 60 HERTZ9.4"W x 18.6"D x 29.1"H NSF, ETL UL, ETL NSF9.3"W x 13"D x 20.7"H UL16.1"W x 23.5"D x 21.5"H 208/240 VAC, 60Hz, 20AMP 42.425"W x 3.531"D x 23.929"H High Mode: 10” x 14” x 8.6 Low Mode: 6.5” x 14” x 8.6”24 Volt NSF8.8"W x20.5"D x 7.5" H GSW USA GSW USA 30"W x 48"L x 35" H 30"W x 36"L x 35" HGSW USA WT-EB3036 NSF ETL NSF ETL 12"W x 20"D x 77" H 18"W x 36"L 14"W x 36"L NSF NSF 18"W x 24"L 18"W x 48"L NSF NSF METRO 4'-0"X1'-6"X6'-0"1848 BR 5 TIES - 18" DEPTHNSF6" LEG 1836 BR 3'-0"X1'-6"X6'-0"5 TIES - 18" DEPTH6" LEGNSFMETRO BLUEAIR 48"X12"WS1248 NSF BLUEAIR 36"X12"WS1236 NSF BLUEAIR 60"X12"WS1260 NSF METRO SUPER ERECTA METRO SUPER ERECTA METRO SUPER ERECTA METRO SUPER ERECTA METRO SUPER ERECTA PITCO 15-5/8"X35"X52"120V, 3PH, 0.5AMPETL6" LEG 44,000BTUBNB-SG14 REGENCY 4'-0"X1'-6"X6'-0"NSF 5 TIES - 18" DEPTH6" LEG REGENCY 5'-0"X1'-6"X6'-0"NSF 5 TIES - 18" DEPTH6" LEG DUMP SINK 1 NSF -DIRECT 1DIPPER WELL KROWNE 16-149 NSF7 3/16 X 6 3/16 NSFNSF INDIRECT (FLOOR MOUNTED) PROVIDE APPROVED BACKFLOW PREVENTER PROVIDE APPROVED BACKFLOW PREVENTER PROVIDE APPROVED BACKFLOW PREVENTER AIR CURTAIN MARS ETL 115V, 9A 1HPAIR VELOCITY MIN.1600FPM (PROVIDED 2389FPM),DOOR SWITCH ACTIVATED TYPE36 "X16"X14"NH-236-1U-TS192 (E)FIXED WINDOW TO REMAIN (E)FIXED WINDOW TO REMAIN (E ) F I X E D W I N D O W TO R E M A I N 01KITCHEN EQUIPMENT PLAN Scale: 1/4" = 1'-0" WATER HEATER 1 SEE PLUMBING DRAWING INDIRECT STANDING SHELF (GREEN) 18" x 36"2 REGENCY 3'-0"X1'-6"X6'-0"NSF 5 TIES - 18" DEPTH6" LEG SELF CLOSING HARDWARE HS-1317 13"X17 1/2"X6 3/8"KROWNE FOLLOWING C.D. I N T E R I O R D E S I G N P-3 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m SO I L , W A S T E A N D V E N T DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T F L O O R P L A N 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 I N T E R I O R D E S I G N P-4 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m KI T C H E N E Q U I P M E N T P L A N DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T 1NO SCALETRAP PRIMER DETAIL 2NO SCALETHREE COMPARTMENT SINK DETAIL 3NO SCALEVENT THRU ROOF DETAIL 5NO SCALEINDIRECT DRAIN DETAIL 6NO SCALEPIPE HANGER DETAIL 7NO SCALEWALL CLEANOUT DETAIL11NO SCALEAREA SEPARATION PENETRATION PIPE TAPPED P-TRAP ADAPTER, PPP INC. OR EQUAL 1/2" COPPER TUBING. ROUTE (THRU PARTITION FOR RESTROOM AND EXPOSED TIGHT TO WALL IN MAINTENANCE) BELOW FLOOR TO P-TRAPS SEE PLAN. DISTRIBUTION UNIT C.W. SUPPLY 3/4"x1/2" TEE. BALL VALVE TRAP PRIMER VALVE "TP" WITH INTEGRAL BACKFLOW PREVENTER AND VACUUM BREAKER PORT. DISTRIBUTION UNIT TO BE MOUNTED (ABOVE CEILING IN MAINTENANCE ROOM AND TOILET ROOM) FINISH FLOOR WASTE LINE P-TRAP PIPE MAY EXTEND AS WASTE OR VENT. PROVIDE CLEANOUT TEE WITH SCREWED COUNTER- SUNK ABS PLASTIC PLUG: TAPERED-THREAD WITH TFE JOINT COMPOUND. WHERE CLEANOUT TEE IS CONCEALED IN A CHASE OR PARTITION, PROVIDE A ROUND 18 GAUGE STAINLESS STEEL COVER WITH BEVELED EDGES AND FLATHEAD MACHINE SCREW. COLUMN OR PARTITION AS SHOWN ON FLOOR PLAN. CLEANOUT FACE SHALL BE WITHIN 4" OF WALL SURFACE. PROVIDE EXTENSION IF REQUIRED. CONCRETE FLOOR SLAB. RISER LENGTH AS REQUIRED HUB AT FLOOR LONG SWEEP AT END OF LINE OR COMBINATION WYE AND EIGHTH BEND IN RUN OF LINE. PROVIDE WCO WHERE SHOWN ON PLAN, AND ON SANITARY WASTE BRANCHES NOT SERVED WITH A FLOOR CLEANOUT: LOCATE ABOVE FIXTURE FLOOD RIM WITHIN 4' OF FLOOR. CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS. DIRECTION OF FLOW TOP BEAM C-CLAMP IF STEEL BAR JOIST ROOF DECK PROVIDE COPPER OR NON-METALLIC COATING WHERE HANGERS CONTACT BARE COPPER PIPE ALL-THREAD ROD. LENGTH AS REQUIRED FOR PIPE SLOPE CLEVIS HANGER FOR PIPE OVER FOUR INCH PROVIDE GALVANIZED STEEL SADDLE FOR ALL INSULATED PIPE LARGER THAN 3/4". VERIFY INSULATION THICKNESS WHEN SIZING HANGERS. DO NOT HANG PIPE LARGER THAN 3" FROM BOTTOM OF JOISTS. ADJUSTABLE BAND HANGER FOR PIPING FOUR INCH OR LESS FLOOR 1"DX COIL CO CO NO INSULATION ON PIPE RISER SEE FLOOR PLAN FOR RECEPTACLE LOCATION. WALK-IN COOLER OR FREEZER BOX INSTALL PIPE HIGH AS POSSIBLE, ANCHORED TO WALL OF BOX WITH SUPPORTS AT MAXIMUM SIX FOOT CENTERS. USE TYPE "M" HARD COPPER TUBE AND FITTINGS WITH LEAD-FREE SOLDER JOINTS. SLOPE HORIZONTAL PIPE AT MINIMUM TWO PERCENT. REFER TO LOCAL CODE FOR INDIRECT DRAIN REQUIREMENTS. PROVIDE A COMPLETE FREEZE PROTECTION SYSTEM FOR CONDENSATE PIPING IN FREEZER BOX EQUIVALENT TO RAYCHEM/TYCO #5XL-1-CR @ 120V, WITH AN OUTPUT OF 5 WATTS PER FOOT AND 40°F START-UP TEMPERATURE. PROVIDE TRAP AT BOTTOM OF RISER AND DISCHARGE INTO FLOOR DRAIN OR FLOOR SINK WITH AIR GAP OF TWO PIPE DIAMETERS SILICONE SEAL AROUND PIPE PENETRATION PROVIDE 1" ELASTOMERIC INSULATION OVER FREEZE PROTECTION ON CONDENSATE LINE PROVIDE CLEANOUT IN TURNS AND ENDS OF PIPE MAKE CONNECTION TO COIL AS REQUIRED REFRIGERANT LINES UP TO REMOTE CONDENSING UNIT ON ROOF. PROVIDE CLEANOUTS IN TURNS/ENDS OF PIPE. USE DWV FITTINGS IF SIZE IS LARGER THAN 1" SLOPE PIPE AS MUCH AS POSSIBLE TOWARD DISCHARGE MAKE CONNECTION TO EQUIPMENT AS REQUIRED DISCHARGE INTO CENTER HOLE OF GRATE OF WASTE RECEPTACLE WITH AIR GAP SUFFICIENT TO REMOVE GRATE AND STRAINER. MINIMUM GAP = TWO PIPE DIAMETERS MAKE PIPE MINIMUM ONE SIZE LARGER THAN EQUIPMENT CONNECTION, MINIMUM 3/4". USE "M" OR "L" HARD COPPER UP TO 1" AND TYPE DWV FOR LARGER ROUTE PIPE INCONSPICUOUSLY AND UNOBTRUSIVELY. HANG PIPE AS REQUIRED. DO NOT INSULATE INDIRECT DRAIN PIPE WHEN INSTALLED EXPOSED IN FOOD SERVICE FACILITY. REFER TO LOCAL CODES FOR FURTHER INFORMATION. VERIFY WITH LOCAL CODES IF/WHEN TRAP AND/OR VENT ARE REQUIRED FOR THE LENGTH OF DRAIN PIPE INSTALLED FCU PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN HERE. DO NOT INSTALL HANGER INSIDE INSULATION OR OTHERWISE PENETRATE VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER EXCEPT IN CHASES. TRAPEZE HANGERS MAY BE USED FOR MULTIPLE PARALLEL PIPES. HANGER SPACING FOR PIPE SIZE: COPPER: 4"=12' 3"=11' 2-1/2"=10' 2"=9' 1-1/2"=8' 1-1/4"=7' 1"=6' 3/4"=6' 1/2"=5'. CAST IRON: 10' AND ONE NEAR ALL JOINTS. STEEL: 4"=14' 3"=12' 2-1/2"=11' 2"=10' 1-1/2"=9' 1"=7' 3/4"=6' 1/2"=5'. LOCATE HANGERS AS CLOSE AS POSSIBLE TO TURNS AND TEES OF PIPE. PROVIDE SUPPLEMENTARY STEEL STRUTS BETWEEN JOISTS IF REQUIRED.LOCATE HANGERS TO TAKE LOAD OFF OF EQUIPMENT CONNECTIONS. DUE TO CHANGES IN WATER VELOCITY. ANCHOR WATER PIPE AGAINST SWAYING PROVIDE SEISMIC BRACING IF/AS REQUIRED BY LOCAL AUTHORITIES. CHAINS OR PERFORATED STRAP IRON OR STEEL IS NOT ACCEPTABLE. REFER TO CODES FOR FURTHER INFORMATION. CONFORM TO MSS SP-58. 1" CONDENSATE DRAIN WITH TRAP BY CONTRACTOR A=FAN STATIC PRESSURE ("W.C.) B= A/2 + 1" A B MIN. 1% SLOPE 4NO SCALECONDENSATE DETAIL8NO SCALECOOLER / FREEZER CONDENSATE DRAIN DETAIL FOR VENT THRU ROOF PROVIDE VENT CAP ROOF PENETRATION (STL. PIPE, TUBE OR SIM. ITEM) CAULK WITH ELASTOMERIC SEALANT DRAW BAND WITH NEOPRENE GASKET WATERTIGHT UMBRELLA ROOFING FLANGE SET IN MASTIC OVER ROOFING- PRIME FLANGE BEFORE STRIPPING FINISHED ROOF DECK REFER TO ARCHITECT AND STRUCTURAL DWGS. 3" 2"V GENERAL NOTE: 1.3-COMPARTMENT SINK SHALL BE CONNECTED DIRECTLY TO THE DRAINAGE SYSTEM , UNLESS DIRECTED OTHERWISE BY COUNTY HEALTH DEPARTMENT. A FLOOR DRAIN SHALL BE PROVIDED ADJACENT TO THE FIXTURE, AND THE FIXTURE SHALL BE CONNECTED ON THE SEWER SIDE OF THE FLOOR DRAIN TRAP; NO OTHER DRAINAGE LINE SHALL BE CONNECTED BETWEEN THE FLOOR DRAIN WASTE CONNECTION AND THE FIXTURE DRAIN. THE FIXTURE AND FLOOR DRAIN SHALL BE TRAPPED AND VENTED IN ACCORDANCE WITH CODE 704.3 ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS OR MEET LOCAL CODE REQUIREMENTS. DWV COPPER PIPE, FITTINGS AND CONNECTORS ALL AROUND SINK. ROUTE COMBINED GREASE DRAIN LINE TO WALL. ROUTE VENT UP, AND GREASE DOWN AS SHOWN ON PLANS. FLOOR SEE NOTE #1 PIPE PIPE COVERING PUTTY: MINIMUM THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS ON TOP SURFACE OF FLOOR. PACKING MATERIAL: MINIMUM 4PCF MINERAL WOOL BATT INSULATION U.L. SYSTEM No. C-AJ-5054 PENETRATING ITEM: COPPER TUBING 1-1/2" DIA (OR SMALLER) TYPE ''L'' OR ''K'' PIPE COVERING PIPE WALL ASSEMBLY (WOOD OR STEEL CHANNEL STUDS WITH GYPSUM WALLBOARD) WALL ASSEMBLY (WOOD OR STEEL CHANNEL STUDS WITH GYPSUM WALLBOARD) PENETRATING ITEM: COPPER TUBING 6 INCH DIA. OR SMALLER TYPE ''L'' OR ''K'' PIPE CAULK FILL MATERIAL INSTALLED TO COMPLETELY FILL ANNULAR SPACE BETWEEN PIPE AND GYPSUM WALL BOARD AND WITH A MINIMUM 1/4INCH DIA. BEAD OF CAULK APPLIED TO PERIMETER OF PIPE AT ITS EGRESS FROM THE WALL. U.L. SYSTEM No. W-L-1001 5/16''DIA x 2''LG. STEEL WALL ANCHOR EQUALLY SPACED (TOTAL OF 6) PENETRATING ITEM: COPPER TUBING 6 INCH DIA. OR SMALLER TYPE ''L'' OR ''K'' PUTTY: MINIMUM 5-INCH OF FILL MATERIAL APPLIED WITHIN THE ANNULUS ON BOTH SURFACES OF THE WALL GALV. SHEET METAL SLEEVE W/ TABS TO RETAIN PUTTY TRIM RING U.L. SYSTEM No. W-L-5001 PENETRATIONS OF PIPES, CONDUITS, ETC., IN WALLS, FLOORS OR CEILING ASSEMBLIES REQUIRING PROTECTED OPENINGS SHALL BE FIRE STOPPED. FIRE STOP MATERIAL SHALL BE A TESTED ASSEMBLY AS PRESCRIBED IN U.B.C. STANDARD 7-5 AND AS APPROVED BT THE OSHPD FIRE MARSHALL (C.B.C. 714) CONCRETE FLOOR CEILING 12NO SCALEINSTANTANEOUS GAS WATER HEATERS PIPING SCHEMATIC 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 I N T E R I O R D E S I G N P-5 ah k | a r c h i t e c t u r e ar c h i t e c t u r e / p l a n n i n g / i n t e r i o r 13 0 0 5 m e s a v e r d e w a y , s y l m a r , c a l i f o r n i a 9 1 3 4 2 em a i l : co n t a c t @ a h k a r c h i t e c t u r e . c o m KI T C H E N E Q U I P M E N T P L A N DE S I G N EL M PA R I S B A G U E T T E TE N A N T I M P R O V E M E N T P R O J E C T 7 L A S T U N A S D R . S U I T E " A " A R C A D I A , C A 9 1 0 0 7 E-mail: pc.philchon@gmail.com 5415 Burning Tree Dr TEL : 213.453.7188 /D&DxDGD)OLQWULGJH&$ PA R I S B A G U E T T E E-1 E-mail: pc.philchon@gmail.com 5415 Burning Tree Dr TEL : 213.453.7188 /D&DxDGD)OLQWULGJH&$ PA R I S B A G U E T T E E-2 E-mail: pc.philchon@gmail.com 5415 Burning Tree Dr TEL : 213.453.7188 /D&DxDGD)OLQWULGJH&$ PA R I S B A G U E T T E E-3 E-mail: pc.philchon@gmail.com 5415 Burning Tree Dr TEL : 213.453.7188 /D&DxDGD)OLQWULGJH&$ PA R I S B A G U E T T E E-4 E-mail: pc.philchon@gmail.com 5415 Burning Tree Dr TEL : 213.453.7188 La Cañada Flintridge, CA 91011 PA R I S B A G U E T T E E-5 Luminaire Schedule Symbol Qty Label Arrangement Total Lamp Lumens LLF Description 18 EX SINGLE N.A.0.70 EMERGENCY UNIT Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min PARIS BAGUETTE ARCADIA EM_Floor Illuminance Fc 2.03 4.7 0.3 6.77 15.67 0.9 2.0 1.7 1.2 1.1 0.9 0.6 1.8 3.4 2.3 2.3 2.9 2.5 1.6 1.7 3.6 2.8 2.8 2.9 2.9 2.2 1.5 2.6 2.5 2.6 3.1 2.2 1.5 1.6 2.5 1.8 2.4 2.7 1.4 1.1 2.4 3.5 1.4 0.6 0.4 0.5 2.7 2.1 1.0 0.9 1.0 0.9 0.9 4.6 2.6 1.4 2.9 2.6 1.6 1.6 1.4 3.0 2.7 1.5 2.6 3.2 0.4 2.2 2.7 2.2 3.2 4.1 2.0 2.1 1.3 1.6 0.3 0.3 1.8 0.6 3.1 4.7 2.1 2.1 2.8 1.3 E-mail: pc.philchon@gmail.com 5415 Burning Tree Dr TEL : 213.453.7188 /D&DxDGD)OLQWULGJH&$ PA R I S B A G U E T T E PH-1