Loading...
HomeMy WebLinkAbout10-51 Miren Pl - 2023 - MIREN SITE LIGHTING PLAN AND GATE MOTORSDESCRIPTIONNO. REVISIONS SHEET SCALE : PROJECT MANAGER : DESIGNER : DRAWN BY : REVIEWED BY : 1ST BLDG. DEPT. SUBMITTAL : ISSUED FOR CONSTRUCTION : JOB NUMBER : CAD FILE NAME : SHEET: DO NOT SCALE PLANS C DATE . MI R E N SI N G L E F A M I L Y D E T A C H E D AR C A D I A , C A L I F O R N I A IN T R A C O R P H O M E S , I N C . NE W P O R T B E A C H , C A -- DD RB Y2-053 DO NOT SCALE PLANS LIGHTING DESIGN | ELECTRICAL ENGINEERING 27201 Calle Juanita Dana Point, CA 92624 Ph. 949.201.1333 candelaengineering.com 04/07/2023 DESCRIPTIONNO. REVISIONS SHEET SCALE : PROJECT MANAGER : DESIGNER : DRAWN BY : REVIEWED BY : 1ST BLDG. DEPT. SUBMITTAL : ISSUED FOR CONSTRUCTION : JOB NUMBER : CAD FILE NAME : SHEET: DO NOT SCALE PLANS C DATE . MI R E N SI N G L E F A M I L Y D E T A C H E D AR C A D I A , C A L I F O R N I A IN T R A C O R P H O M E S , I N C . NE W P O R T B E A C H , C A -- DD RB Y2-053 DO NOT SCALE PLANS LIGHTING DESIGN | ELECTRICAL ENGINEERING 27201 Calle Juanita Dana Point, CA 92624 Ph. 949.201.1333 candelaengineering.com 04/07/2023 ES1.1 TITLE SHEET 1 3GENERAL ELECTRICAL NOTES 1.INTERIOR WIRING PERMITTED TO BE TYPE NM CABLE IN ACCORDANCE WITH NEC ARTICLE 334 AND LOCAL CODES IN ONE- AND TWO- FAMILY AND MULTIFAMILY DWELLINGS OF TYPE III, IV, AND V CONSTRUCTION. IN OTHER TYPES OF TYPE III, IV, AND V CONSTRUCTION NM CABLE MAY BE ACCEPTABLE EXCEPT FOR EXPOSED IN ACCESSIBLE DROPPED OR EXPOSED CEILINGS OR WHERE PROHIBITED IN NEC 334.12. CONTRACTOR TO VERIFY NM CABLE WIRING METHOD WITH AUTHORITY HAVING JURISDICTION PRIOR TO BIDDING THE JOB. MINIMUM WIRING SIZE PER THE 60 DEGREE C COLUMN OF NEC TABLE 310.15(B)(16) (I.E. #12 CU FOR 20A CIRCUIT BREAKERS). 2.ALL WIRING TO COMPLY WITH NEC ARTICLE 300. CONDUCTORS SHALL BE INSTALLED IN CODE APPROVED RACEWAYS AS REQUIRED. 3.INSTALL THE ELECTRICAL SYSTEM USING CONSTRUCTION MEANS, METHODS, AND, MATERIALS, IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS / INSTRUCTIONS, TRADE STANDARDS, AND APPLICABLE NATIONAL AND LOCAL CODES. 4.PROVIDE ALL LABOR, MATERIALS, TOOLS, PERMITS, FEES, TRANSPORTATION, ETC TO PROVIDE THE OWNER A COMPLETE AND FUNCTIONING ELECTRICAL SYSTEM TO THE OWNER'S SATISFACTION. 5.DRAWINGS ARE NECESSARILY DIAGRAMMATIC BY THEIR NATURE AND ARE NOT INTENDED TO SHOW EVERY CONNECTION IN DETAIL OR EVERY PIPE OR CONDUIT IN ITS EXACT LOCATION. CAREFULLY INVESTIGATE STRUCTURAL AND FINISH CONDITIONS AND COORDINATE THE SEPARATE TRADES IN ORDER TO AVOID INTERFERENCE BETWEEN THE VARIOUS PHASES OF WORK. ORGANIZE AND LAYOUT WORK SO THAT IT WILL BE CONCEALED IN WALLS, FURRED CHASES, AND CEILINGS, ETC., IN FINISHED PORTIONS OF THE BUILDING, UNLESS SPECIFICALLY NOTED TO BE EXPOSED. INSTALL ALL WORK PARALLEL OR PERPENDICULAR TO BUILDING LINES UNLESS OTHERWISE NOTED. 6.HALF SIZED OR TANDEM CIRCUIT BREAKERS MAY BE USED ONLY IF THE ELECTRICAL EQUIPMENT IS LISTED TO RECEIVE SUCH DEVICES. 7.RECESSED LIGHTING FIXTURES WITH DIRECT CONTACT WITH INSULATION SHALL BE TYPE IC (LISTED BY RECOGNIZED TESTING AGENCY). RECESSED NON-TYPE IC FIXTURES SHALL HAVE A MINIMUM OF 3” CLEAR FROM INSULATION AND 1” FROM COMBUSTIBLE MATERIALS (NON-TYPE IC RECESSED FIXTURES ARE NOT PERMITTED IN RESIDENTIAL UNITS). 8.RECESSED LIGHTING IN RATED ASSEMBLIES SHALL BE EITHER “FIREBOXED” TO MAINTAIN THE RATING OF THE ASSEMBLY OR UTILIZE A LISTED FIXTURE WITH ENCLOSURE THAT MAINTAINS THE ORIGINAL RATING OF THE ASSEMBLY. 9.RECESSED ELECTRICAL PANELS IN RATED ASSEMBLIES SHALL BE “FIREBOXED” TO MAINTAIN THE ORIGINAL RATING OF THE ASSEMBLY. 10.ALL PENETRATIONS (ELECTRICAL BOXES, CABLE, CONDUIT, ETC…) THROUGH RATED ASSEMBLIES SHALL BE SEALED OR FIRE STOPPED TO MAINTAIN THE RATING OF THE ASSEMBLY WITH A LISTED FIRE STOPPING SYSTEM (I.E. 3M FIRE BARRIER OR EQUAL) IN COMPLIANCE WITH CBC SECTION 712. CONTRACTOR TO INSTALL FIRE STOPPING SYSTEM PER MANUFACTURER'S INSTRUCTIONS AND SPECIFICATIONS. 11.ALL LIGHTING SWITCHES SHALL BE RATED FOR 120-277V, “DECORA” STYLE, AND WHITE UNLESS OTHERWISE NOTED IN THE PLANS OR OWNER'S SPECIFICATIONS. 12.ALL GENERAL USE RECEPTACLES SHALL BE NEMA 5-15R, “DECORA” STYLE, AND WHITE UNLESS OTHERWISE NOTED IN THE PLANS OR OWNER'S SPECIFICATIONS. 13.ALL OUTDOOR RECEPTACLES SHALL BE GFCI PROTECTED AND LISTED AS “WR” WEATHER RESISTANT TYPE PER NEC 406.9. OUTDOOR RECEPTACLES IN DAMP LOCATIONS SHALL HAVE WEATHERPROOF COVERS. OUTDOOR RECEPTACLES IN WET LOCATIONS SHALL HAVE “IN-USE” TYPE WEATHERPROOF COVERS. 14.ALL EXTERIOR JUNCTION BOXES SHALL BE LISTED AS WEATHERPROOF WITH WEATHERPROOF COVERS. 15.ALL ELECTRICAL EQUIPMENT AND DEVICES SHALL BE NEW AND SUPPLIED WITH ALL THE NECESSARY FITTINGS, ATTACHMENTS, AND ACCESSORIES FOR A COMPLETE INSTALLATION. 16.HIGH EFFICACY LUMINARIES SHALL BE DEFINED AS FOLLOWS:30 LUMENS PER WATT (FOR LAMPS 5W OR LESS) 40 LUMENS PER WATT (FOR LAMPS 6W-15W) 50 LUMENS PER WATT (FOR LAMPS 16W-40W) 17.MEDIUM AND CANDELABRA BASED SCREW-IN LAMPS DO NOT QUALIFY AS HIGH EFFICACY. GU-24 PIN BASES QUALIFY AS HIGH EFFICACY. 18.ALL WALL FIXTURES IN SHALL BE INSTALLED SUCH THAT THE LOWEST PORTION OF THE FIXTURE PROTRUDING > 4” IS 80” ABOVE THE FINISHED GRADE OR HIGHER. 19.REFER TO PLUMBING, HVAC, LOW VOLTAGE, COMMUNICATION, ACCESS CONTROL, INTERIOR DESIGN, AND ARCHITECTURE DRAWINGS AND PROVIDE ALL REQUIRED CONTROL WIRES, RELAYS, DISCONNECTS, STARTERS, CONDUITS, TIME SWITCHES, AND OUTLETS REQUIRED. ALL WORK AND MATERIALS INDICATED IN THE ABOVE CONSULTANT'S DRAWINGS AS SUPPLIED BY THE ELECTRICIAN SHALL BE PROVIDED UNDER THIS SCOPE OF WORK. 20.ELECTRICAL SYSTEM TO BE GROUNDED PER NEC ARTICLE 250. 21.REFER TO ACOUSTICAL ANALYSIS / SPECIFICATIONS; PROVIDE PUTTY PADS OR OTHER SYSTEMS AS REQUIRED FOR SOUND ATTENUATION. 22.ELECTRICAL DEVICES INSTALLED ON OPPOSITE SIDES OF WALLS SHALL BE SEPARATED BY A MINIMUM OF 24” (I.E. NOT IN THE SAME STUD BAY). IF DEVICES ARE CLOSER THAN 24” OR THE BOX SIZE EXCEEDS 16 SQIN, THEN A PUTTY PADS (OR SIMILAR FIRE BARRIER) ARE REQUIRED FOR THOSE DEVICES. IF THE DENSITY OF OUTLET OPENINGS EXCEEDS 100SQIN FOR ANY 100SQFT OF WALL, THEN PUTTY PADS ARE REQUIRED FOR THE ENTIRE WALL. 23.ALL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY AND SUPPORTED ACCORDING TO APPLICABLE OSHA REQUIREMENTS. 24.CONTRACTOR TO WARRANTY ALL WORK COMPLETED FOR A PERIOD OF ONE YEAR AFTER THE OWNER'S ACCEPTANCE DATE. ANY LABOR OR MATERIALS REQUIRED TO CORRECT FAULTY OR DEFECTIVE WORK WITHIN THE WARRANTY PERIOD SHALL BE CORRECTED AT THE EXPENSE OF THE CONTRACTOR. 25.CONTRACTOR TO PROVIDE THE OWNER (1) SET OF “AS-BUILT” DRAWINGS FOR THE OWNER'S RECORD AT THE COMPLETION OF THE JOB. 26.CONTRACTOR TO CONFIRM ALL LOW VOLTAGE CABLING REQUIREMENTS PRIOR TO BIDDING THE JOB. 27.PROPERLY LABEL ALL ELECTRICAL ROOMS / CABINETS, ELECTRICAL PANELS, TIME SWITCHES, PANEL SCHEDULES, AND MULTI-GANG METERS. PROVIDE ALL LABELING AND PLAQUES SPECIFIED IN THE CONTRACT DOCUMENTS. 28.PROVIDE A MINIMUM OF A 4FTX8FTX3/4IN FIRE RATED PLYWOOD BACKBOARD WITH A #6 COPPER (MIN) GROUND BONDED TO BUILDING GROUNDING SYSTEM AND A DEDICATED DUPLEX RECEPTACLE PROTECTED BY A 20A/1P CIRCUIT AT THE MAIN POINT OF ENTRANCE FOR THE CATV / PHONE PROVIDERS. 29.SWITCHGEAR DIMENSIONS ARE BASED ON THE APPROXIMATE DIMENSIONS OF THE MANUFACTURER SPECIFIED IN THE PLANS. IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY THE EQUIPMENT WILL FIT IN THE ACTUAL SPACE PRIOR TO ORDERING THE EQUIPMENT. 30.CONTRACTOR SHALL REVIEW THE ELECTRICAL, AND OTHER CONSULTANTS DRAWINGS PRIOR TO STARTING ANY WORK AND INFORM THE ENGINEER OF ANY DISCREPANCIES, OMISSIONS, OR IF CLARIFICATIONS ARE REQUIRED TO COMPLETE THE INSTALLATION PRIOR TO COMMENCING THE WORK. 31.PROVIDE THE OWNER WITH 1 COPY OF ALL OPERATION AND MAINTENANCE MANUALS FOR LIGHTING, LIGHTING CONTROL, AND ELECTRICAL SYSTEMS. 32.LABEL ELECTRICAL SERVICE EQUIPMENT WITH THE MAXIMUM AVAILABLE FAULT CURRENT AT THE INCOMING TERMINALS OF THE EQUIPMENT PER NEC 110.24 33.IT IS PROHIBITED TO SHARE NEUTRAL CONDUCTORS FOR THREE SINGLE PHASE CIRCUITS PER NEC 200.4. 34.ALL CABLE TRAYS CONTAINING TYPE SE, MC, MI, OR IGS SERVICE ENTRANCE CABLES MUST BE LABELED “CABLE TRAY CONTAINS SERVICE ENTRANCE CONDUCTORS”. 35.CONTRACTOR TO PROVIDE SUBMITTALS FOR ALL ELECTRICAL EQUIPMENT, ELECTRICAL MATERIALS AND LIGHTING FIXTURES FOR APPROVAL PRIOR TO ORDERING. 2P 2 POLE 3P 3 POLE AFCI ARC-FAULT CIRCUIT INTERRUPTER AIC AMPERE INTERRUPTING CAPACITY AL ALUMINUM AFF ABOVE FINISHED FLOOR AWG AMERICAN WIRE GAUGE CEC CALIFORNIA ELECTRIC CODE C CELSIUS CLK CLOCK (ASTRO. TIME CLOCK) CO CONDUIT ONLY CU COPPER EMT ELECTRICAL METALLIC TUBING GFCI GROUND FAULT CIRCUIT INTERRUPTER GND GROUND F FAHRENHEIT FC FOOTCANDLE FT FEET IESNA ILLUMINATION ENGINEERING SOCIETY NORTH AMERICA IMC INTERMEDIATE METAL CONDUIT K KELVIN (DEGREES) KAIC 1,000 AIC M METERS NEC NATIONAL ELECTRIC CODE NEG NEGLIGIBLE NM NON-METALLIC NTS NOT TO SCALE PB PUSH BUTTON POC POINT OF CONNECTION PVC POLYVINYL CHLORIDE (SCHEDULE 40 UNLESS OTHERWISE NOTED) RMC RIGID METALLIC CONDUIT SPEC SPECIFICATION(S) TITLE 24 CALIFORNIA BUILDING ENERGY CODE - TITLE 24 VD VOLTAGE DROP WP WEATHER PROOF WR WEATHER RESISTANT XFMR TRANSFORMER 9ELECTRICAL SYMBOL LEGEND 8ABBREVIATIONS CIRCUIT BREAKER FUSE GROUND DUPLEX RECEPTACLE GFCI PROTECTED RECEPTACLE MOUNTED IN CEILING QUAD-PLEX RECEPTACLE SPLIT WIRED "HALF-HOT" RECEPTACLE JUNCTION BOX GFCI PROTECTED RECEPTACLE W/ WEATHERPROOF COVERWP GFCI PROTECTED RECEPTACLE J RECESSED ELECTRICAL PANEL 3d 3 WAY DIMMER SWITCH 3 3 WAY SWITCH D DIMMER SWITCH V MANUAL ON - AUTOMATIC OFF "VACANCY" SENSOR SWITCH SURFACE MOUNTED ELECTRICAL PANEL SINGLE POLE SWITCH 3d 3 D V 4 4 WAY SWITCH4 H HUMIDISTAT WALL SWITCHH M ELECTRICAL METER SWITCH M MOTOR T TRANSFROMER 5 7 NO. 3 1/2 UNDERGROUND PULL BOX ELECTRICAL SERVICE PEDESTAL IRRIGATION CONTROLLER •2019 CALIFORNIA ELECTRIC CODE (CEC) •2019 CALIFORNIA BUILDING CODE (CBC) •2019 CALIFORNIA ENERGY CODE (TITLE 24) NON-RESIDENTIAL MANDATORY MEASURES APPLICABLE CODES 2 11 PANEL SCHEDULE ELECTRICAL PEDESTAL DETAIL ELECTRICAL PEDESTAL - SINGLE LINE DIAGRAM NOT TO SCALE NOT TO SCALE PANEL IDENTIFICATION LANDSCAPING 18" MIN NONMETALLIC RACEWAY (I.E. PVC CONDUIT) LOW VOLTAGE (>30V) LANDSCAPE LIGHTING DIRECT BURIAL CABLE 6" MIN STREETS, HIGHWAYS, ROADS ALLEYS, DRIVEWAYS, AND PARKING LOTS 24" MIN NONMETALLIC RACEWAY (I.E. PVC CONDUIT), RIGID METAL CONDUIT AND DIRECT BURIAL CABLES RIGID METAL CONDUIT OR INTERMEDIATE METAL CONDUIT 4MINIMUM COVER REQUIREMENTS UTILITY M 100A-2P TO LIGHTING N G #8 CU-GND 3" (C.O.) (VERIFY) ELECTRICAL SERVICE PEDESTAL (COMBO IRRIGATION CONTROLLER) 120/240V, 1Ø, 3W. 100A/2P CIRCUIT BREAKER MAIN 42,000 AIC SERIES RATED (MAX) VIT STRONGBOX # MPE-A16-65K-STAINLESS STEEL WITH 7DAY ASTRONOMICAL TIME CLOCK, 18"W X 20"D X 52"H (2 ) 1 " C . O . SP A R E ( F U T U R E ) CONTACTORS & NO 3-1/2 PULLBOX TIME CLOCK P1 TEST BLOCKS EUSERC CO. STAINLESS STEEL AND COPPER DRIVEN GROUND ROD ((2) 5/8" DIA. X 10FT (MIN)) INSTALL PER NEC 250.53 OR OTHER APPROVED METHOD ADJACENT TO PEDESTAL FOR FUTURE USE AND TWO 6-POLE CONTACTORS 1. 2.COMMERCIAL METER SOCKET 100A WITH TEST BLOCKS 3.SERVICE METER VIEWING WINDOW STRONGBOX SERVICE PEDESTAL STAINLESS STEEL NEMA TYPE 3R MPE-A16-10K- 100AMP SERVICE 4.SIDE HINGED REMOVABLE FRONT LID 5.LOAD CENTER WITH MAIN BREAKER 8.POURED CONCRETE BASE - 6" MIN. THICKNESS - EXTEND CONCRETE 6" BEYOND OUTSIDE DIMENSION OF ENCLOSURE WITH 12% SLOPE AWAY FOR DRAINAGE. 6.LOAD CENTER COMPARTMENT, GASKETED DOOR WITH T-HANDLE, PADLOCKABLE. 9.STAINLESS ANCHOR BASE INSTALLED DURING CONCRETE POUR AND CONDUIT PLACEMENT PART NO. MPS-BASE 10.UTILITY LANDING LUG COMPARTMENT 11.LOAD CONDUIT 52" 7.SERVICE LINE CONDUIT 3" FROM UTILITY TRANSFORMER. WIRE SIZE PER NEC STANDARDS FOR AMPERAGE LOAD. STRONGBOX CONTROL ENCLOSURE FULL LENGTH FRONT DOOR, PADLOCKABLE, PART NO. SB-1852SS 18" x 52" x 12". 12. LOAD CONDUIT FROM LOAD CENTER SECTION INTO CUSTOMER ENCLOSURE SB-1852SS. MIN. (2)2" AS PER NEEDED 13. 14.PHOTOCELL WINDOW 10OUTDOOR LIGHTING CONTROL SCHEMATIC ATC CONTACTOR TIME CLOCK 2 3 1 NOT USED. (2) 6-POLE LIGHTING CONTACTOR, 20A (MIN), 120V COIL IN NEMA 1 ENCLOSURE SQUARE-D# 8903-LG60-V02 OR EQUAL ASTRONOMICAL TIME CLOCK & AUTOMATIC TIME SWITCH INTERMATIC# ET8215C OR APPROVED EQUAL (2 CHANNEL) OUTDOOR LIGHTING ON AND OFF BY ASTRO TIME CLOCK (DUSK - DAWN) 2 3 4 4 4 CLK FOR THE PURPOSE GROUND CLAMP LISTED 6FT (MIN) GFI IN PEDESTAL PX SECTION 130 – LIGHTING CONTROLS AND EQUIPMENT—GENERAL (A) EXCEPT AS PROVIDED IN SUBSECTIONS (B) AND (C), THE DESIGN AND INSTALLATION OF ALL LIGHTING SYSTEMS AND EQUIPMENT IN NONRESIDENTIAL, HIGH-RISE RESIDENTIAL, HOTEL/MOTEL BUILDINGS, AND OUTDOOR LIGHTING SUBJECT TO TITLE 24, PART 6, SHALL COMPLY WITH THE APPLICABLE PROVISIONS OF SECTIONS 131 THROUGH 139. ALL LIGHTING CONTROLS AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. (B) INDOOR LIGHTING IN HIGH-RISE RESIDENTIAL DWELLING UNITS AND HOTEL/MOTEL GUEST ROOMS. THE DESIGN AND INSTALLATION OF ALL LIGHTING SYSTEMS, LIGHTING CONTROLS AND EQUIPMENT IN HIGH-RISE RESIDENTIAL DWELLING UNITS AND IN HOTEL/MOTEL GUEST ROOMS SHALL COMPLY WITH THE APPLICABLE PROVISIONS OF SECTION 150(K). (C) OUTDOOR LIGHTING FOR HIGH-RISE RESIDENTIAL DWELLING UNITS AND HOTEL/MOTEL GUEST ROOMS. OUTDOOR LIGHTING THAT IS PERMANENTLY ATTACHED TO THE BUILDING, AND IS SEPARATELY CONTROLLED FROM THE INSIDE OF A HIGH-RISE RESIDENTIAL DWELLING UNIT OR GUEST ROOM SHALL COMPLY WITH SECTION 150(K)13. (D) LUMINAIRE POWER. LUMINAIRE WATTAGE SHALL BE DETERMINED AS FOLLOWS, OR BY A METHOD APPROVED BY THE EXECUTIVE DIRECTOR: 1. THE WATTAGE OF LUMINAIRES WITH LINE VOLTAGE LAMP HOLDERS, OTHER THAN GU-24 AS DETERMINED ACCORDING TO SECTION 130(E), AND NOT CONTAINING PERMANENTLY INSTALLED BALLASTS OR TRANSFORMERS SHALL BE DETERMINED AS FOLLOWS: A. FOR OTHER THAN RECESSED LUMINARIES, THE MAXIMUM RELAMPING RATED WATTAGE OF THE LUMINAIRE, AS LISTED ON A PERMANENT, PRE-PRINTED, FACTORY-INSTALLED LABEL, AS SPECIFIED BY UL 1598. B. FOR RECESSED LUMINAIRES, THE LARGER OF THE MAXIMUM RELAMPING RATED WATTAGE OF THE LUMINAIRE, AS LISTED ON A PERMANENT, PRE-PRINTED, FACTORY-INSTALLED LABEL, AS SPECIFIED BY UL 1598, OR THE FOLLOWING: I. 50 WATTS PER SOCKET FOR LUMINAIRES WITH HOUSINGS OR TRIMS WITH AN APERTURE DIAMETER LESS THAN 5 INCHES REGARDLESS OF MOUNTING HEIGHT; OR II. 50 WATTS PER SOCKET FOR LUMINAIRES WITH HOUSINGS OR TRIMS WITH AN APERTURE DIAMETER OF GREATER THAN OR EQUAL TO 5 INCHES AND A MOUNTING HEIGHT OF 11 FEET OR LESS, OR III. 60 WATTS PER SOCKET FOR LUMINAIRES WITH HOUSINGS OR TRIMS WITH AN APERTURE DIAMETER OF GREATER THAN OR EQUAL TO 5 INCHES AND A MOUNTING HEIGHT OF GREATER THAN 11 FEET BUT LESS THAN 15 FEET; OR IV. 75 WATTS PER SOCKET FOR LUMINAIRES WITH HOUSINGS OR TRIMS WITH AN APERTURE DIAMETER OF GREATER THAN OR EQUAL TO 5 INCHES AND A MOUNTING HEIGHT OF 15 FEET OR MORE. C. FOR LUMINAIRES DESIGNED TO ACCOMMODATE A VARIETY OF TRIMS OR MODULAR COMPONENTS THAT ALLOW THE CONVERSION BETWEEN SCREW-BASED AND PIN-BASED SOCKETS WITHOUT CHANGING THE LUMINAIRE HOUSING OR WIRING, THE HIGHEST WATTAGE DESIGNATED BY THE CORRELATED MARKING ON A PERMANENT, PRE-PRINTED, FACTORY-INSTALLED LABEL ON THE LUMINAIRE HOUSING SHALL BE USED. D. FOR LUMINAIRES WITH LINE VOLTAGE LAMP HOLDERS, THE FACTORY-INSTALLED WATTAGE LABEL SHALL NOT CONSIST OF PEEL-OFF OR PEEL-DOWN LAYERS OR OTHER METHODS WHICH ALLOW THE RATED WATTAGE TO BE CHANGED AFTER THE LUMINAIRE HAS BEEN SHIPPED FROM THE MANUFACTURER. 2. THE WATTAGE OF LUMINAIRES WITH PERMANENTLY INSTALLED OR REMOTELY INSTALLED BALLASTS SHALL BE THE OPERATING INPUT WATTAGE OF THE RATED LAMP/BALLAST COMBINATION PUBLISHED IN MANUFACTURER’S CATALOGS BASED ON INDEPENDENT TESTING LAB REPORTS AS SPECIFIED BY UL 1598. THE WATTAGE OF A COMPACT FLUORESCENT OR HIGH INTENSITY DISCHARGE LUMINAIRE THAT CAN ACCOMMODATE A RANGE OF WATTAGES WITHOUT CHANGING THE LUMINAIRE HOUSING, BALLAST, OR WIRING SHALL BE THE LARGER OF THE INSTALLED WATTAGE, OR THE AVERAGE WATTAGE OF THE LAMP/BALLAST COMBINATIONS FOR WHICH THE LUMINAIRE IS RATED. 3. THE WATTAGE OF LINE-VOLTAGE LIGHTING TRACK AND PLUG-IN BUSWAY WHICH ALLOWS THE ADDITION OR RELOCATION OF LUMINAIRES WITHOUT ALTERING THE WIRING OF THE SYSTEM SHALL BE DETERMINED BY ONE OF THE FOLLOWING METHODS: A. THE WATTAGE OF LINE VOLTAGE BUSWAY AND TRACK RATED FOR MORE THAN 20 AMPERES SHALL BE THE TOTAL VOLT-AMPERE RATING OF THE BRANCH CIRCUIT FEEDING THE BUSWAY AND TRACK. B. THE WATTAGE OF LINE VOLTAGE BUSWAY AND TRACK RATED FOR 20 AMPERES OR LESS SHALL BE DETERMINED BY ONE OF THE FOLLOWING METHODS: I. THE VOLT-AMPERE RATING OF THE BRANCH CIRCUIT FEEDING THE TRACK OR BUSWAY; OR II. THE HIGHER OF THE RATED WATTAGE OF ALL OF THE LUMINAIRES INCLUDED IN THE SYSTEM, WHERE WATTAGE IS DETERMINED ACCORDING TO SECTION 130(D)1, 2, 4, 5, OR 6 AS APPLICABLE, OR 45 WATTS PER LINEAR FOOT; OR III. WHEN USING AN INTEGRAL CURRENT LIMITER, THE HIGHER OF THE VOLT-AMPERE RATING OF AN INTEGRAL CURRENT LIMITER CONTROLLING THE TRACK OR BUSWAY, OR 12.5 WATTS PER LINEAR FOOT OF TRACK OR BUSWAY, PROVIDED THAT THE INTEGRAL CURRENT LIMITER COMPLIES WITH SECTION 119(L); OR IV. WHEN USING A DEDICATED TRACK LIGHTING SUPPLEMENTARY OVERCURRENT PROTECTION PANEL, THE SUM OF THE AMPERE (A) RATING OF ALL OF THE OVERCURRENT PROTECTION DEVICES TIMES THE BRANCH CIRCUIT VOLTAGES. THE PANEL SHALL MEET ALL OF THE FOLLOWING REQUIREMENTS: A. BE LISTED AS DEFINED IN SECTION 101; AND B. BE USED ONLY WITH LINE VOLTAGE TRACK LIGHTING; AND C. BE PERMANENTLY INSTALLED IN AN ELECTRICAL EQUIPMENT ROOM, OR PERMANENTLY INSTALLED ADJACENT TO THE LIGHTING PANEL BOARD PROVIDING SUPPLEMENTARY OVERCURRENT PROTECTION FOR THE TRACK LIGHTING CIRCUITS SERVED BY THE SUPPLEMENTARY OVER CURRENT PROTECTION PANEL; AND D. BE PROMINENTLY LABELED "NOTICE: THIS PANEL FOR TRACK LIGHTING ENERGY CODE COMPLIANCE ONLY. THE OVERCURRENT PROTECTION DEVICES IN THIS PANEL SHALL ONLY BE REPLACED WITH THE SAME OR LOWER AMPERAGE. NO OTHER OVERCURRENT PROTECTIVE DEVICE SHALL BE ADDED TO THIS PANEL. ADDING TO, OR REPLACEMENT OF EXISTING OVERCURRENT PROTECTIVE DEVICE(S) WITH HIGHER CONTINUOUS AMPERE RATING, WILL VOID THE PANEL LISTING AND REQUIRE RE-SUBMITTAL AND RE-CERTIFICATION OF CALIFORNIA TITLE 24, PART 6 COMPLIANCE DOCUMENTATION.” 4. THE WATTAGE OF LUMINAIRES OR LIGHTING SYSTEMS WITH PERMANENTLY INSTALLED OR REMOTELY INSTALLED TRANSFORMERS SHALL BE DETERMINED AS FOLLOWS: A. THE RATED WATTAGE OF THE LAMP/TRANSFORMER COMBINATION, LISTED ON A PERMANENT, PRE-PRINTED, FACTORY-INSTALLED LABEL, AS SPECIFIED BY UL 2108, AND B. FOR LUMINAIRES OR LIGHTING SYSTEMS WITH TRANSFORMERS RATED GREATER THAN 53 WATTS, THE FACTORY-INSTALLED WATTAGE LABEL SHALL NOT CONSIST OF PEEL-OFF OR PEEL-DOWN LAYERS OR OTHER METHODS WHICH ALLOW THE RATED WATTAGE TO BE CHANGED AFTER THE LUMINAIRE OR LIGHTING SYSTEM HAS BEEN SHIPPED FROM THE MANUFACTURER. 5. THE WATTAGE OF LIGHT EMITTING DIODE (LED) LUMINAIRES, OR LED LIGHT ENGINE WITH INTEGRAL HEAT SINK SHALL BE THE MAXIMUM RATED INPUT WATTAGE OF THE SYSTEM WHEN TESTED IN ACCORDANCE WITH REFERENCE JOINT APPENDIX JA8. THE MAXIMUM RATED INPUT WATTAGE SHALL BE LISTED ON A PERMANENT, PRE-PRINTED, FACTORY-INSTALLED LABEL. 6. THE WATTAGE OF ALL OTHER MISCELLANEOUS LIGHTING EQUIPMENT SHALL BE THE MAXIMUM RATED WATTAGE OF THE LIGHTING EQUIPMENT, OR OPERATING INPUT WATTAGE OF THE SYSTEM, LISTED ON A PERMANENT, PRE-PRINTED, FACTORY-INSTALLED LABEL, OR PUBLISHED IN MANUFACTURER’S CATALOGS, BASED ON INDEPENDENT TESTING LAB REPORTS AS SPECIFIED BY UL 1574 OR UL 1598. (E) GU-24 LAMPS, LUMINAIRES, AND ADAPTORS. GU-24 LAMPS, LUMINAIRES, AND ADAPTORS INSTALLED IN CALIFORNIA SHALL MEET THE FOLLOWING REQUIREMENTS: 1. LAMPS WITH GU-24 BASES SHALL HAVE A MINIMUM EFFICACY NO LOWER THAN SPECIFIED IN TABLE 150-C. 2. THE WATTAGE OF LUMINAIRES WITH GU-24 LAMP HOLDERS SHALL BE THE OPERATING INPUT WATTAGE AS LISTED ON A PERMANENT, PRE-PRINTED, FACTORY-INSTALLED LABEL ON THE LUMINAIRE HOUSING, AS SPECIFIED BY UL. LUMINAIRES WITH GU-24 LAMPHOLDERS SHALL NOT BE RATED FOR ANY LAMP OR LIGHTING SYSTEM THAT HAS AN EFFICACY LOWER THAN SPECIFIED IN TABLE 150-C. 3. LUMINAIRES WITH GU-24 LAMPHOLDERS SHALL NOT HAVE MODULAR COMPONENTS ALLOWING CONVERSION TO ANY LAMP OR LIGHTING SYSTEM THAT HAS AN EFFICACY LOWER THAN SPECIFIED IN TABLE 150-C. 4. THERE SHALL BE NO ADAPTORS THAT CONVERT A GU-24 SOCKET OR GU-24 LAMP HOLDER TO ANY OTHER LINE VOLTAGE SOCKET OR LAMP HOLDER, OR TO ANY LIGHTING SYSTEM THAT HAS AN EFFICACY LOWER THAN SPECIFIED IN TABLE 150-C. J 6TITLE MIREN SINGLE FAMILY DETACHED SITE LIGHTING AND POWER PLAN ARCADIA, CALIFORNIA PROJECT TO COMPLY WITH 2022 CEC, CBC, AND CALIFORNIA ENERGY CODE CITY OF ARCADIA DEVELOPMENT SERVICES DIVISION APPROVED By Subject to field inspection approval. The stamping of this plan and specifications SHALL NOT be held to permit or to be an approval of the violation of any provisions of any City Ordinance, State Law or Recognized Standard __________________________AAD 05/16/2023 ALL EXPOSED CONDUIT AND MECHANICAL EQUIPMENT SHALL BE PAINTED TO MATCH ROOF AND WALLS. EXTERIOR SITE ELECTRICAL NOTES LIGHTING FIXTURE LEGEND ELECTRICAL DEVICE LEGEND JUNCTION BOXJ ELECTRICAL PANEL ELECTRICAL KEY NOTES LED WALL LIGHT - (1000 LUMEN MIN AT 3000°K) MOUNTED AT 7'-0" TO BOTTOM EDGE OF FIXTURE J UNDERGROUND PULL BOX 1 TRANSFORMER - DIRECT BURIAL T LANDSCAPING 18" MIN NONMETALLIC RACEWAY (I.E. PVC CONDUIT) LOW VOLTAGE (>30V) LANDSCAPE LIGHTING DIRECT BURIAL CABLE 6" MIN STREETS, HIGHWAYS, ROADS ALLEYS, DRIVEWAYS, AND PARKING LOTS 24" MIN NONMETALLIC RACEWAY (I.E. PVC CONDUIT), RIGID METAL CONDUIT AND DIRECT BURIAL CABLES RIGID METAL CONDUIT OR INTERMEDIATE METAL CONDUIT MINIMUM COVER REQUIREMENTS 210 H..-X 2 #10 THHN/THWN-2-CU & 1 #10 CU-GND IN 3/4" SCH. 40 PVC. CONDUIT INDICATES CIRCUIT NUMBER (TYPICAL) 3 10 3 #10 THHN/THWN-2-CU & 1 #10 CU-GND IN 3/4" SCH. 40 PVC. CONDUIT H..-X 212 2 #12 THHN/THWN-2-CU & 1 #12 CU-GND IN 3/4" SCH. 40 PVC. CONDUIT H..-X IRRIGATION CONTROLER A 1.EXTERIOR SITE LIGHTING CONDUCTORS TO BE # 12 THHN/THWN-2 CU IN 3/4" SCHEDULE 40 PVC CONDUIT UNLESS OTHERWISE NOTED. MINIMUM COVER PER NEC 300.5(A) (SEE THIS SHEET) 2.UNDERGROUND PULL BOXES ARE TO BE SIZE 3-1/2. ADDITIONAL PULL BOXES MAY BE NEEDED THAN CURRENTLY SHOWN ON THE PLANS TO HELP IN PULLING THE CONDUCTORS DURING INSTALLATION. THE COVER OF THE PULL BOXES ARE TO BE MARKED WITH "ELECTRIC". 3.SPLICES AND TAPS SHALL BE MADE IN PULL BOXES OR POLE BASE HAND HOLES ONLY. 4.REFER TO THE DRY UTILITY CONSULTANT PLANS OR SERVING UTILITY PLANS TO CONFIRM THE SERVICE LOCATION PRIOR TO BEGINNING UNDERGROUND WORK. 5.ELECTRICAL CONTRACTOR SHALL INSTALL A 3/16" MIN. PULL ROPE IN ALL EMPTY CONDUITS OR SLEEVES. 6.UNDERGROUND CONDUIT SHALL BE PVC SCHEDULE 40, UNLESS LOCAL CODES OR THE SOILS REPORT REQUIRE A DIFFERENT TYPE OF CONDUIT. 7.THE ELECTRICAL CONTRACTOR MUST NEVER HAVE A GENERAL LIGHTING FIXTURE (WALL LIGHT, POLE LIGHT, BOLLARD, ETC.) WIRED AFTER AN ACCENT LIGHT SUCH THAT IF THE ACCENT LIGHT WAS REMOVED OR DAMAGED IT WOULD AFFECT THE GENERAL LIGHTING FIXTURE'S POWER. 8.THE ELECTRICAL CONTRACTOR MUST FLIP THE CIRCUIT BREAKER TO OFF BEFORE ANY MAINTENANCE OR REPLACEMENT OF AN ELECTRICAL FIXTURE, LAMP, DEVICE OR CONTROLLER. 9.IF GATES FOR PEDESTRIANS AND/OR VEHICLES ARE TO BE INSTALLED; THE ELECTRICAL CONTRACTOR IS TO COORDINATE WITH THE GATE CONTRACTOR(S) TO MAKE SURE ANY NECESSARY CONDUITS, CIRCUITS OR WIRING ARE TO BE INSTALLED OTHER THAN WHAT IS SHOWN ON THIS PLAN. ALSO, LOW VOLTAGE CONDUIT MAY ALSO BE NEEDED FOR ACCESS CONTROL. COORDINATE ON LOCATION AND REQUIREMENTS FOR KNOX BOX, PROVIDE EQUIPMENT AS REQUIRED. BBQ RECEPTACLE. COORDINATE WORK WITH BARBEQUE INSTALLER. VERIFY POWER FOR IGNITER. AIM LIGHTS TO EVENLY WASH THE POOL DECK.2 SELECT BY OWNER ELECTRICAL PANEL IDENTIFICATION (1) 4" PVC SCHEDULE 40 PRIVATE ELEC. SLEEVE H..-X CIRCUIT IDENTIFIER CIRCUIT NUMBER PANEL IDENTIFICATION VD=X.X%VOLTAGE DROP HP1 CONTROLLED BY ASTRO. TIME CLOCK. WITH NOT OVERIDE A4 HSS HOUSE SIDE SHIELD PER PLAN. NOT ALL FIXTURES TO HAVE A SHIELD. (FOCUS INDUSTRIES) 70W. LED POST LIGHT - TYPE IV USA# DSAP25-VLED-IV-64LED-350mA-NW-120-XPD-RAL-9005-S-MS-F211 (4"DIA) - 3000°K POLE MODEL# RNTS 235-11-PT27-RAL-9005-S A1 SAME AS ABOVE BUT NON-TYPICAL LOCATIONS 70W. LED POST LIGHT - TYPE III USA# DSAP25-VLED-III-64LED-350mA-NW-120-XPD-RAL-9005-S-MS-F211 (4"DIA) - 3000°K POLE MODEL# RNTS 235-11-PT27-RAL-9005-S 70W. LED POST LIGHT - TYPE II USA# DSAP25-VLED-II-64LED-350mA-NW-120-XPD-RAL-9005-S-MS-F211 (4"DIA) - 3000°K POLE MODEL# RNTS 235-11-PT27-RAL-9005-S A2 A3 1 1A SO U T H S A N T A A N I T A A V E N U E PRIVATE DRIVEWAY AND FIRELANE 356.11 FH 4 1A 7 1A 10 1A 13 1A2 1BR 5 1BR 8 1BR 11 1BR3 2BR 6 2AR 9 2BR 12 2AR 14 3AR(X) 15 3B(X) 16 1A(E)22 1A(E) 28 1A(E) 21 1BR(E)27 1BR(E) 33 1BR(X) 18 2AR 24 2AR 30 2AR19 2B 25 2B 31 2B 17 3BR 23 3BR 29 3BR 20 3A 26 3A 32 3A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A AAAA A A A A AA A A A A A A A AAAAA A A A A A A A AAA A1 A1 A1 A1 A1 A1 A1 A A A A A2 HSS A2 HSS A4 HSS J J M M P1 P1-1 212 ENTIRERUN P1-4,6 4 8 ENTIRE RUN A3 HSS HSS A2 DESCRIPTIONNO. REVISIONS SHEET SCALE : PROJECT MANAGER : DESIGNER : DRAWN BY : REVIEWED BY : 1ST BLDG. DEPT. SUBMITTAL : ISSUED FOR CONSTRUCTION : JOB NUMBER : CAD FILE NAME : SHEET: DO NOT SCALE PLANS C DATE . MI R E N SI N G L E F A M I L Y D E T A C H E D AR C A D I A , C A L I F O R N I A IN T R A C O R P H O M E S , I N C . NE W P O R T B E A C H , C A -- DD RB Y2-053 DO NOT SCALE PLANS LIGHTING DESIGN | ELECTRICAL ENGINEERING 27201 Calle Juanita Dana Point, CA 92624 Ph. 949.201.1333 candelaengineering.com 04/07/2023 DESCRIPTIONNO. REVISIONS SHEET SCALE : PROJECT MANAGER : DESIGNER : DRAWN BY : REVIEWED BY : 1ST BLDG. DEPT. SUBMITTAL : ISSUED FOR CONSTRUCTION : JOB NUMBER : CAD FILE NAME : SHEET: DO NOT SCALE PLANS C DATE . MI R E N SI N G L E F A M I L Y D E T A C H E D AR C A D I A , C A L I F O R N I A IN T R A C O R P H O M E S , I N C . NE W P O R T B E A C H , C A -- DD RB Y2-053 DO NOT SCALE PLANS LIGHTING DESIGN | ELECTRICAL ENGINEERING 27201 Calle Juanita Dana Point, CA 92624 Ph. 949.201.1333 candelaengineering.com 04/07/20231PHOTOMETRIC SITE PLAN SCALE: 1" = 20'-0" ES1.1 SITE ELECTRIC CITY OF ARCADIA DEVELOPMENT SERVICES DIVISION APPROVED By Subject to field inspection approval. The stamping of this plan and specifications SHALL NOT be held to permit or to be an approval of the violation of any provisions of any City Ordinance, State Law or Recognized Standard __________________________AAD 05/16/2023 ALL EXPOSED CONDUIT AND MECHANICAL EQUIPMENT SHALL BE PAINTED TO MATCH ROOF AND WALLS. LIGHTING FIXTURE LEGEND LED WALL LIGHT - (1000 LUMEN MIN AT 3000°K) MOUNTED AT 7'-0" TO BOTTOM EDGE OF FIXTUREA SELECT BY OWNER CONTROLLED BY ASTRO. TIME CLOCK. WITH NOT OVERIDE A4 HSS HOUSE SIDE SHIELD PER PLAN. NOT ALL FIXTURES TO HAVE A SHIELD. 70W. LED POST LIGHT - TYPE IV USA# DSAP25-VLED-IV-64LED-350mA-NW-120-XPD-RAL-9005-S-MS-F211 (4"DIA) - 3000°K POLE MODEL# RNTS 235-11-PT27-RAL-9005-S A1 SAME AS ABOVE BUT NON-TYPICAL LOCATIONS 70W. LED POST LIGHT - TYPE III USA# DSAP25-VLED-III-64LED-350mA-NW-120-XPD-RAL-9005-S-MS-F211 (4"DIA) - 3000°K POLE MODEL# RNTS 235-11-PT27-RAL-9005-S 70W. LED POST LIGHT - TYPE II USA# DSAP25-VLED-II-64LED-350mA-NW-120-XPD-RAL-9005-S-MS-F211 (4"DIA) - 3000°K POLE MODEL# RNTS 235-11-PT27-RAL-9005-S A2 A3 1 1A SO U T H S A N T A A N I T A A V E N U E PRIVATE DRIVEWAY AND FIRELANE 356.11 FH 4 1A 7 1A 10 1A 13 1A2 1BR 5 1BR 8 1BR 11 1BR3 2BR 6 2AR 9 2BR 12 2AR 14 3AR(X) 15 3B(X) 16 1A(E)22 1A(E) 28 1A(E) 21 1BR(E)27 1BR(E) 33 1BR(X) 18 2AR 24 2AR 30 2AR19 2B 25 2B 31 2B 17 3BR 23 3BR 29 3BR 20 3A 26 3A 32 3A 0.9 0.5 1.0 1.1 1.0 0.9 1.1 1.2 1.3 1.0 0.7 1.5 1.2 1.4 1.5 1.2 0.9 0.8 1.1 1.3 1.4 1.3 1.2 1.1 1.1 1.3 1.3 1.5 1.5 1.5 0.9 1.0 1.1 1.3 1.3 1.4 1.2 1.1 1.0 1.1 1.1 1.2 1.1 1.0 1.1 1.2 0.6 0.6 1.1 1.2 1.5 1.9 1.5 1.3 1.2 0.6 0.6 1.1 1.2 1.4 1.5 1.3 1.0 0.8 0.6 0.7 1.0 1.0 1.1 1.2 1.9 1.1 1.6 0.8 0.7 0.8 0.8 0.8 0.9 0.7 0.8 0.7 0.6 1.0 0.8 0.7 0.6 1.4 1.0 0.9 0.8 1.1 1.1 1.1 1.0 1.2 1.3 1.1 1.2 1.2 0.9 1.0 1.1 0.9 0.8 1.0 1.3 0.9 0.9 1.1 1.1 1.1 1.2 1.2 0.9 0.7 1.3 1.1 1.3 1.4 1.2 1.7 1.1 1.5 0.8 0.7 1.4 1.0 1.2 1.3 1.1 1.0 0.9 0.9 0.7 0.8 2.0 1.0 1.1 1.0 1.0 1.7 1.0 1.4 0.9 0.7 1.1 1.0 0.8 0.7 1.0 0.8 1.6 0.9 0.7 0.6 1.0 0.9 0.8 0.7 0.9 1.0 0.9 1.0 1.2 1.1 1.0 1.2 1.3 1.1 1.2 1.2 0.9 0.9 1.1 0.9 0.8 1.0 1.4 1.0 1.0 1.1 1.0 1.2 1.2 1.2 0.8 0.7 1.1 1.1 1.3 1.4 1.2 1.3 0.9 1.1 0.8 0.8 1.9 1.1 1.2 1.2 1.2 1.3 0.9 1.1 0.7 0.8 1.9 0.9 0.9 0.9 0.7 0.7 0.7 1.0 0.8 0.7 0.6 1.0 0.8 0.6 0.5 1.3 0.9 0.7 0.6 1.1 1.0 0.8 1.2 1.2 1.1 1.3 1.4 1.2 1.3 1.4 1.2 1.2 1.2 1.3 1.1 1.2 2.5 1.2 1.3 1.9 1.3 1.5 1.9 1.3 1.6 2.0 1.2 1.3 1.2 1.0 0.9 0.8 A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A AAAA A A A A AA A A A A A A A AAAAA A A A A A A A AAA A1 A1 A1 A1 A1 A1 A1 A A A A A2 HSS A2 HSS A4 HSS HSS HSS A2 DESCRIPTIONNO. REVISIONS SHEET SCALE : PROJECT MANAGER : DESIGNER : DRAWN BY : REVIEWED BY : 1ST BLDG. DEPT. SUBMITTAL : ISSUED FOR CONSTRUCTION : JOB NUMBER : CAD FILE NAME : SHEET: DO NOT SCALE PLANS C DATE . MI R E N SI N G L E F A M I L Y D E T A C H E D AR C A D I A , C A L I F O R N I A IN T R A C O R P H O M E S , I N C . NE W P O R T B E A C H , C A -- DD RB Y2-053 DO NOT SCALE PLANS LIGHTING DESIGN | ELECTRICAL ENGINEERING 27201 Calle Juanita Dana Point, CA 92624 Ph. 949.201.1333 candelaengineering.com 04/07/2023 DESCRIPTIONNO. REVISIONS SHEET SCALE : PROJECT MANAGER : DESIGNER : DRAWN BY : REVIEWED BY : 1ST BLDG. DEPT. SUBMITTAL : ISSUED FOR CONSTRUCTION : JOB NUMBER : CAD FILE NAME : SHEET: DO NOT SCALE PLANS C DATE . MI R E N SI N G L E F A M I L Y D E T A C H E D AR C A D I A , C A L I F O R N I A IN T R A C O R P H O M E S , I N C . NE W P O R T B E A C H , C A -- DD RB Y2-053 DO NOT SCALE PLANS LIGHTING DESIGN | ELECTRICAL ENGINEERING 27201 Calle Juanita Dana Point, CA 92624 Ph. 949.201.1333 candelaengineering.com 04/07/20231PHOTOMETRIC SITE PLAN SCALE: 1" = 20'-0" EP1.1 SITE PHOTOMETRIC CITY OF ARCADIA DEVELOPMENT SERVICES DIVISION APPROVED By Subject to field inspection approval. The stamping of this plan and specifications SHALL NOT be held to permit or to be an approval of the violation of any provisions of any City Ordinance, State Law or Recognized Standard __________________________AAD 05/16/2023 ALL EXPOSED CONDUIT AND MECHANICAL EQUIPMENT SHALL BE PAINTED TO MATCH ROOF AND WALLS.