Loading...
HomeMy WebLinkAbout298 E Live Oak Ave - 2023 - REPLACE EXISTING EV POWER UNITS AND 2 EV CHARGING DISPENSERSPROJECT DESCRIPTIONSITE INFORMATION CONTRACTOR NOTE CONTRACTOR SHALL COMPLETE INSTALL PER THE SIGNED AND THE SEALED SET OF DRAWINGS. ANY NECESSARY DEVIATIONS FROM THE DRAWINGS MUST BE SUBMITTED THROUGH AN RFI REQUEST PROCESS WITH ENGINEERING FOR AN APPROVAL PRIOR TO CONTRACTOR PROCEEDING WITH A DEVIATION OF THE SIGNED AND SEALED SET OF DRAWINGS. CALL BEFORE YOU DIG ENGINEER OF RECORD SHEET NO: DRAWING INDEX SHEET TITLE REV NO: DO NOT SCALE DRAWINGS ZONING INFORMATION FLOOD HAZARD AREA NOTE APPLICABLE CODES FOR REFERENCE ONLY DRAWINGS CONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK. 11"x17" PLOT WILL BE HALF SCALE UNLESS NOTED REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 0 04/18/23 ISSUED FOR CONSTRUCTION CA200050 ARCADIA ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 NMB KKP 406879 TITLE SHEET & PROJECT DATA T-1 ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 THIS SITE IS LOCATED IN FLOOD ZONE "X". AREA DETERMINED TO BE OUTSIDE OF THE 0.2% ANNUAL CHANCE FLOOD PLAIN. PERMITTING JURISDICTION:CITY OF ARCADIA, CA ZONING CLASS:(MU) MIXED USE SITE SITE SOUTHERN CALIFORNIA EDISON CORY SKILLERN (909) 357-6249 POWER COMPANY: EQUIPMENT SUPPLIER: COUNTY: LOS ANGELES LATITUDE (NAD83): 34° 06' 25.80" N 34.107177° LONGITUDE (NAD83): 118° 01' 27.80" W -118.024387° THE VONS COMPANIES INC. PROPERTY OWNER: CONTACT ENGINEER: ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 RUSSELL POLLOM (913) 458-6274 POLLOMRE@BV.COM LOCATION MAPAREA MAP CA200050 ARCADIA INSTALLATION OF ELECTRIC VEHICLE CHARGING EQUIPMENT 298 E. LIVE OAK AVE. ARCADIA, CA 91006 EV SITE ADDRESS: UNDERGROUND SERVICE ALERT UTILITY NOTIFICATION CENTER OF CALIFORNIA 811 OR 1-800-227-2600 3 WORKING DAYS UTILITY NOTIFICATION PRIOR TO CONSTRUCTION ALL WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA ENERGY CODE IN THE EVENT OF CONFLICT, THE MOST RESTRICTIVE CODE SHALL PREVAIL NOEL HERRERA PE # C 80849 BLACK & VEATCH CORPORATION ·REMOVE (3) BTC POWER UNITS ·INSTALL (2) BTC GEN IV POWER UNITS ·REMOVE (2) BTC GEN I DISPENSERS ·INSTALL (2) BTC GEN IV DISPENSERS 0TITLE SHEET & PROJECT DATA C-2 T-1 ENLARGED SITE PLANC-3 C-4 GENERAL NOTES 1GN-1 GENERAL NOTES 2GN-2 ENLARGED EQUIPMENT LAYOUT AND BEAM DETAIL E-1 E-2 D-1 EQUIPMENT DETAILS SINGLE LINE DIAGRAM ELECTRICAL DETAILSE-3 0 0 0 0 0 0 0 0 0 0 EQUIPMENT REMOVAL SITE PLAN ELECTRICAL PLAN D-2 EQUIPMENT DETAILS E-1.1 0ELECTRICAL PLAN AC WIRE ROUTING E-1.2 0ELECTRICAL PLAN DC WIRE ROUTING C-4.1 W-BEAM DETAIL 0 APN: 8572002010 C-1 0PLOT PLAN C80849 4/18/2023 3/31/25 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 0 04/18/23 ISSUED FOR CONSTRUCTION CA200050 ARCADIA ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 NMB KKP 406879 GENERAL NOTES 1 GN-1 GENERAL CONSTRUCTION NOTES GENERAL CONSTRUCTION NOTES CONT. 1.FOR THE PURPOSE OF CONSTRUCTION DRAWINGS, THE FOLLOWING DEFINITIONS SHALL APPLY GENERAL CONTRACTOR: OVERLAND CONTRACTING INC. (BLACK & VEATCH) CONTRACTOR: (CONSTRUCTION) OWNER: ELECTRIFY AMERICA 2.ALL SITE WORK SHALL BE COMPLETED AS INDICATED ON THE DRAWINGS. 3.THE GENERAL CONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED WORK AND SHALL MAKE PROVISIONS. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. 4.ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. GENERAL CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF WORK. 5.ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE REGULATIONS. 6.UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 7.PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY UNLESS OTHERWISE NOTED. DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS THE MINIMUM REQUIRED CLEARANCE. THEREFORE, IT IS CRITICAL TO FIELD VERIFY DIMENSIONS, SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF WORK AND PREPARED BY THE ENGINEER PRIOR TO PROCEEDING WITH WORK. 8.THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9.IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVAL BY THE ENGINEER PRIOR TO PROCEEDING. 10.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA, ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA REQUIREMENTS AND THE LOCAL JURISDICTION. 11.THE GENERAL CONTRACTOR SHALL COORDINATE WORK AND SCHEDULE WORK ACTIVITIES WITH OTHER DISCIPLINES. 12.CONSTRUCTION SHALL BE DONE IN A WORKMANLIKE MANNER BY COMPETENT EXPERIENCED WORKMAN IN ACCORDANCE WITH APPLICABLE CODES AND THE BEST ACCEPTED PRACTICE. 13.WORK PREVIOUSLY COMPLETED IS REPRESENTED BY LIGHT SHADED LINES AND NOTES. THE SCOPE OF WORK FOR THIS PROJECT IS REPRESENTED BY DARK SHADED LINES AND NOTES. CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR OF ANY EXISTING CONDITIONS THAT DEVIATE FROM THE DRAWINGS PRIOR TO BEGINNING CONSTRUCTION. 14.THE CONTRACTOR SHALL PROVIDE WRITTEN NOTICE TO THE CONSTRUCTION MANAGER 48 HOURS PRIOR TO COMMENCEMENT OF WORK. 15.THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE OWNER. 16.THE GENERAL CONTRACTOR SHALL COORDINATE AND MAINTAIN ACCESS FOR ALL TRADES AND CONTRACTORS TO THE SITE AND/OR BUILDING. 17.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FOR THE DURATION OF CONSTRUCTION UNTIL JOB COMPLETION. 18.THE GENERAL CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES. 19.THE CONTRACTOR SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS WITH A RATING OF NOT LESS THAN 2-A:10-B:C AND SHALL BE WITHIN 25 FEET OF TRAVEL DISTANCE TO ALL PORTIONS OF WHERE THE WORK IS BEING COMPLETED DURING CONSTRUCTION. 20.ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY THE ENGINEER. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. THE CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS SHALL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION, B) CONFINED SPACE, C) ELECTRICAL SAFETY, AND D) TRENCHING & EXCAVATION. 21.ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED, CAPPED, PLUGGED OR OTHERWISE DISCONNECTED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, AS DIRECTED BY THE ENGINEER, AND SUBJECT TO THE APPROVAL OF THE OWNER AND/OR LOCAL UTILITIES. 22.ALL NECESSARY RUBBISH, STUMPS, DEBRIS, STICKS, STONES, AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A LAWFUL MANNER. 23.ALL BROCHURES, OPERATING AND MAINTENANCE MANUALS, CATALOGS, SHOP DRAWINGS, AND OTHER DOCUMENTS SHALL BE TURNED OVER TO THE GENERAL CONTRACTOR AT COMPLETION OF CONSTRUCTION AND PRIOR TO PAYMENT. 24.THE CONTRACTOR SHALL SUBMIT A COMPLETE SET OF AS-BUILT REDLINES TO THE GENERAL CONTRACTOR UPON COMPLETION OF PROJECT AND PRIOR TO FINAL PAYMENT. 25.THE CONTRACTOR SHALL LEAVE PREMISES IN A CLEAN CONDITION. 26.THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE, AND IS NOT FOR HUMAN HABITATION (NO HANDICAP ACCESS REQUIRED). 27.NO OUTDOOR STORAGE OR SOLID WASTE CONTAINERS ARE PROPOSED. 28.CONTRACTORS SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REQUIRED FOR CONSTRUCTION. IF CONTRACTOR CANNOT OBTAIN A PERMIT, THEY MUST NOTIFY THE GENERAL CONTRACTOR IMMEDIATELY. 29.THE CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. 30.INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND/OR DRAWINGS PROVIDED BY THE SITE OWNER. CONTRACTORS SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. STRUCTURAL STEEL NOTES 1.STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS, UNLESS NOTED OTHERWISE: WIDE FLANGE SHAPE: A992, 50ksi ANGLE AND CHANNEL SHAPE: ASTM A36, 36 ksi PLATE: ASTM A36, 36ksi PIPE: ASTM A53 GRADE B, 35 ksi HSS: ASTM A500 GRADE B, 46ksi 2.HIGH-STRENGTH BOLTS SHALL CONFORM TO ASTM A325: ONE HIGH-STRENGTH BOLT ASSEMBLY SHALL CONSIST OF A HEAVY HEX STRUCTURAL BOLT, A HEAVY NUT, A HARDENED WASHER CONFORMING TO ASTM F436. THE HARDENED WASHER SHALL BE INSTALLED AGAINST ELEMENT TURNED IN TIGHTENING. UNLESS NOTED OTHERWISE ON THE DRAWINGS, ALL CONNECTIONS SHALL BE BEARING TYPE CONNECTIONS. 3.WELDING ELECTRODES SHALL COMPLY WITH AWS D1.1 USING A5.1 OR A5.5 E70XX AND SHALL BE COMPATIBLE WITH THE WELDING PROCESS SELECTED. WELDERS SHALL BE QUALIFIED AS PRESCRIBED IN AWS D1.1. 4.UNLESS NOTED OTHERWISE ON THE DRAWING, ALL ANCHOR BOLTS SHALL CONFORM TO ASTM F1554, GRADE 36, WITH HEAVY HEXAGONAL NUT. 5.FABRICATE ITEMS OF STRUCTURAL STEEL IN ACCORDANCE WITH AISC SPECIFICATION. 6.ALL EXPOSED STRUCTURAL STEEL, BOLTS, AND HARDWARE SHALL BE HOT DIP GALVANIZED PER ASTM A123. 7.SUBMIT FABRICATION AND ERECTION DRAWINGS SHOWING ALL DETAILS, CONNECTIONS, MATERIAL DESIGNATIONS, AND TOP STEEL ELEVATIONS FOR APPROVAL. THE SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL CONFORMANCE TO THE CONTRACT DRAWINGS. SUCH APPROVAL SHALL NOT RELIEVE THE FABRICATOR/CONTRACTOR OF THE RESPONSIBILITY FOR EITHER THE ACCURACY OF THE DETAILED DIMENSIONS IN THE SHOP AND ERECTION DRAWINGS OR THE GENERAL FIT-UP OF PARTS THAT ARE TO BE ASSEMBLED IN THE FIELD. 8.PRIMER SHALL BE RED OXIDE-CHROMATE PRIME COMPLYING WITH STEEL STRUCTURES PAINTING COUNCIL (SSPC) PAINT SPECIFICATION NUMBER 11 GENERAL SITE WORK NOTES GENERAL SITE WORK NOTES CONT. 1.DRILLING THROUGH EXISTING SLAB REBAR DURING POST-INSTALLED ANCHOR BOLTS INSTALLATION IS NOT PERMITTED. 2.POST-INSTALLED ANCHOR BOLT INSTALLATION SHALL BE PERFORMED BY PERSONNEL TRAINED TO INSTALL THE SYSTEM PER THE MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS (MPII), AS INCLUDED IN THE ANCHOR PACKAGING. 3.EXPANSION AND ADHESIVE ANCHORS SHALL BE INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS USING STANDARD EMBEDMENTS AND EDGE DISTANCES UNLESS NOTED OTHERWISE ON THE DRAWINGS. ANCHORAGE INSTALLATION NOTES PART 1 - GENERAL CLEARING, GRUBBING, STRIPPING, EROSION CONTROL, SURVEY, LAYOUT, SUBGRADE PREPARATION AND FINISH GRADING AS REQUIRED TO COMPLETE THE PROPOSED WORK SHOWN IN THESE PLANS. 1.1 REFERENCES: A.DOT (STATE DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION-CURRENT EDITION). B.ASTM (AMERICAN SOCIETY FOR TESTING AND MATERIALS). C.OSHA (OCCUPATION SAFETY AND HEALTH ADMINISTRATION). 1.2 INSPECTION AND TESTING: A. GENERAL CONTRACTOR SHALL PERFORM ALL WORK IN CONFORMANCE WITH THE PLANS AND SPECIFICATIONS. PERFORM INSPECTIONS BEFORE CONCEALING WORK WITH FOLLOW-ON ACTIVITIES (BACKFILL, CONCRETE POUR, ETC). 1.3 SITE MAINTENANCE AND PROTECTION: A.PROVIDE ALL NECESSARY JOB SITE MAINTENANCE FROM COMMENCEMENT OF WORK UNTIL COMPLETION OF THE CONTRACT. B.AVOID DAMAGE TO THE SITE AND TO EXISTING FACILITIES, STRUCTURES, TREES, AND SHRUBS DESIGNATED TO REMAIN. TAKE PROTECTIVE MEASURES TO PREVENT EXISTING FACILITIES THAT ARE NOT DESIGNATED FOR REMOVAL FROM BEING DAMAGED BY THE WORK. C.KEEP SITE FREE OF ALL PONDING WATER. D.PROVIDE AND MAINTAIN ALL TEMPORARY FENCING, BARRICADES, WARNING SIGNALS AND SIMILAR DEVICES NECESSARY TO PROTECT AGAINST THEFT FROM PROPERTY DURING THE ENTIRE PERIOD OF CONSTRUCTION. REMOVE ALL SUCH DEVICES UPON COMPLETION OF THE WORK. E.EXISTING UTILITIES: DO NOT INTERRUPT EXISTING UTILITIES SERVING FACILITIES OCCUPIED BY THE OWNER OR OTHERS, EXCEPT WHEN PERMITTED IN WRITING BY THE CONSTRUCTION MANAGER AND THEN ONLY AFTER ACCEPTABLE TEMPORARY UTILITY SERVICES HAVE BEEN PROVIDED. F.PROVIDE A MINIMUM 48-HOUR NOTICE TO THE CONSTRUCTION MANAGER AND RECEIVE WRITTEN NOTICE TO PROCEED BEFORE INTERRUPTING ANY UTILITY SERVICE. PART 3 - EXECUTION 3.1 GENERAL: A.BEFORE ALL SURVEY, LAYOUT, STAKING, AND MARKING, ESTABLISH AND MAINTAIN ALL LINES, GRADES, ELEVATIONS AND BENCHMARKS NEEDED FOR EXECUTION OF THE WORK. CONDUCT UTILITY LOCATE IN ACCORDANCE WITH THE ONE-CALL NOTIFICATION 3.6 ASPHALT PAVING ROAD: A. CONTRACTOR RESPONSIBLE FOR RE-STRIPING AND APPLYING SEALCOATING, UNLESS OTHERWISE SPECIFIED. B.ALL ELECTRIC VEHICLE CHARGING STALLS WITH AN ASPHALT SURFACE SHALL BE REPAIRED TO EXISTING CONDITION IF DAMAGED. CALIFORNIA STANDARD SPECIFICATIONS SECTION 39 - CALIFORNIA DEPARTMENT OF TRANSPORTATION PAVEMENT C80849 4/18/2023 3/31/25 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 0 04/18/23 ISSUED FOR CONSTRUCTION CA200050 ARCADIA ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 NMB KKP 406879 GENERAL NOTES 2 GN-2 ELECTRICAL NOTES 1.THE ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL ANY/ALL ELECTRICAL WORK INDICATED. ANY/ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH DRAWINGS AND ANY/ALL APPLICABLE SPECIFICATIONS. IF ANY PROBLEMS ARE ENCOUNTERED BY COMPLYING WITH THESE REQUIREMENTS, CONTRACTOR SHALL NOTIFY 'CONSTRUCTION MANAGER' AS SOON AS POSSIBLE, AFTER THE DISCOVERY OF THE PROBLEMS, AND SHALL NOT PROCEED WITH THAT PORTION OF WORK, UNTIL THE 'CONSTRUCTION MANAGER' HAS DIRECTED THE CORRECTIVE ACTIONS TO BE TAKEN. 2.THE ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AND FAMILIARIZE THEMSELVES WITH ANY/ALL CONDITIONS AFFECTING ELECTRICAL AND COMMUNICATION INSTALLATION AND MAKE PROVISIONS AS TO THE COST THEREOF. THE CONDITION OF EXISTING ELECTRICAL EQUIP., LIGHT FIXTURES, ETC., THAT ARE PART OF THE FINAL SYSTEM, SHALL BE VERIFIED BY THE CONTRACTOR, PRIOR TO THE SUBMITTAL OF HIS BID. FAILURE TO COMPLY WITH THIS PARAGRAPH WILL IN NO WAY RELIEVE CONTRACTOR OF PERFORMING ALL WORK NECESSARY FOR A COMPLETE AND WORKING SYSTEM. 3.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE CEC AND ALL CODES AND LOCAL ORDINANCES OF THE LOCAL POWER COMPANIES HAVING JURISDICTION AND SHALL INCLUDE BUT NOT BE LIMITED TO: A. UL - UNDERWRITERS LABORATORIES B. CEC - CALIFORNIA ELECTRICAL CODE C. NEMA - NATIONAL ELECTRICAL MANUFACTURERS ASSOC. D. OSHA - OCCUPATIONAL SAFETY AND HEALTH ACT E. SBC - STANDARD BUILDING CODE F. NFPA - NATIONAL FIRE PROTECTION ASSOCIATION 4.DO NOT SCALE ELECTRICAL DRAWINGS, REFER TO SITE PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT, BUT CONFIRM WITH 'CONSTRUCTION MANAGER' ANY SIZES AND LOCATIONS WHEN NEEDED. 5.CONDUCTORS: CONTRACTOR SHALL USE 98% CONDUCTIVITY COPPER OR ALUMINUM WITH TYPE (XHHW-2) INSULATION, 1000 VOLT, COLOR CODED UNLESS SPECIFIED DIFFERENTLY ON DRAWINGS. 6.ALL WIRING INSTALLATIONS SHALL BE COMPLIANT WITH NEC ARTICLE 310.10 AND TO FOLLOW MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. 7.IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF THE CONSTRUCTION. CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS FOR THE EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. CONTRACTOR IS TO PROVIDE ALL ELECTRICAL EQUIPMENT UNLESS OTHERWISE DIRECTED. 8.ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS, WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIONAL AND SUBJECT TO REGULATORY INSPECTION AND APPROVAL BY CONSTRUCTION MANAGER. 9.CONTRACTOR SHALL GUARANTEE ANY/ALL MATERIALS AND WORK FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE YEAR FROM DATE OF ACCEPTANCE. 10.THE CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ANY ADDITIONAL CHARGE AND SHALL INCLUDE THE REPLACEMENT OR THE REPAIR OF ANY OTHER PHASE OF THE INSTALLATION, WHICH MAY HAVE BEEN DAMAGED THEREIN. 11.ADEQUATE AND REQUIRED LIABILITY INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LOSS AND ANY/ALL PROPERTY DAMAGE FOR THE DURATION OF WORK. 12.CONNECTORS FOR POWER CONDUCTORS: CONTRACTOR SHALL USE PRESSURE TYPE INSULATED TWIST-ON CONNECTORS FOR NO. 10 AWG AND SMALLER. USE SOLDERLESS MECHANICAL TERMINAL LUGS FOR NO. 8 AWG AND LARGER. FIBER OPTIC NOTES USE CABLE WITH THE FOLLOWING MINIMUM PROPERTIES: 1. HIGH TENSILE STRENGTH >150 LB 2. TIGHT BUFFERED 3. INDOOR / OUTDOOR UV AND MOISTURE RESISTANT “RISER” CABLE 4. CONNECTOR TYPE: ST-ST 5. FIBER TYPE: MULTI-MODE 6-FIBER (3 PAIR) 62.5UM OR OM3. 6 CONNECTORS ON BOTH ENDS. 6. JACKET: INDOOR/OUTDOOR RISER, BLACK 7. BREAKOUT: SIDE A: INNER END - 24 INCHES WITH 2MM FURCATION SIDE B: OUTER END - 24 INCHES - 2MM FURCATION - STAGGERED EVERY 1" 8. WITH PULLING EYE ON SIDE B (OUTER END) AND SPOOL REEL C80849 4/18/2023 3/31/25 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 0 04/18/23 ISSUED FOR CONSTRUCTION CA200050 ARCADIA ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 NMB KKP 406879 PLOT PLAN C-1 NO SCALEPLOT PLAN EXISTING EV CHARGER LOCATION NOTE 1.NOTED PAGE SCALE IS NOT CORRECT DUE TO RESIZING TO INCLUDE IN CONSTRUCTION DRAWING PACKAGE. C80849 4/18/2023 3/31/25 FRO N T EXISTING LEVEL 2 CHARGER TO REMAIN UNCHANGED REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 0 04/18/23 ISSUED FOR CONSTRUCTION CA200050 ARCADIA ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 NMB KKP 406879 EQUIPMENT REMOVAL SITE PLAN C-2 6'4'2'0 5'10' 3/16"=1'-0" EQUIPMENT REMOVAL SITE PLAN EXISTING TREE (TYP) EXISTING ASPHALT PARKING LOT EXISTING PARKING STRIPE (TYP) EXISTING CONCRETE SIDEWALK EXISTING PROPERTY LINE EXISTING UTILITY TRANSFORMER 1 EXISTING PARKING STRIPE (TYP) 1 2 3 4 EXISTING BOLLARD (TYP) EXISTING UNDERGROUND ELECTRIC LINE (TYP) EXISTING UNDERGROUND GAS LINE (TYP)EXISTING UNDERGROUND FIBER OPTIC LINE (TYP) EXISTING FIBEROPTIC PEDESTAL (TYP) EXISTING FIBER OPTIC VAULT (TYP) EXISTING IRRIGATION CONTROL VALVE (TYP) EXISTING OVERHEAD ELECTRIC LINE (TYP) EXISTING SETBACK LINE EXISTING UTILITY POLE EXISTING BUSH (TYP) EXISTING CONCRETE CURB WITH GUTTER (TYP) LY N R O S E S T EXISTING LIGHT POLE (TYP) 2 3 EXISTING CONCRETE CURB WITH GUTTER EXISTING CONTOUR LINE (TYP) EXISTING STUB OUT LOCATION FOR FUTURE DISPENSER EXISTING BUSH (TYP) NOTES 1.SOD PLANTED IN THE FALL MUST ESTABLISH ITS ROOTS BEFORE THE FIRST WINTER FROST. DETERMINE WHEN THE FIRST FROST USUALLY OCCURS, AND PLANT THE SOD NO LATER THAN ONE MONTH BEFORE THE FIRST FROST. IF THE CONSTRUCTION IS FINISHED LATER THAN ONE MONTH BEFORE THE FIRST FROST, USE STRAW UNTIL SOD CAN BE INSTALLED. 2.THE CONTRACTOR SHALL RETURN SIDEWALKS, LANDSCAPING, PLANTERS, IRRIGATION SYSTEMS, AND ANY OTHER FACILITIES DISTURBED BY THE WORK TO THE SAME OR BETTER CONDITION THAN EXISTED PRIOR TO THE COMMENCEMENT OF THE WORK. REMOVE EXISTING BTC POWER UNIT (TYP OF 3) EXISTING BTC DISPENSER TO REMAIN UNCHANGED EXISTING DISPENSER DISPENSER NUMBER 150 KW LEVEL 2 CABLE TYPE 1 1 CCS 2 1 CCS/CHAdeMO 3 1 CCS 4 1 J1772 REMOVE EXISTING BTC DISPENSER (TYP OF 2) C80849 4/18/2023 3/31/25 FRO N T EXISTING LEVEL 2 CHARGER TO REMAIN UNCHANGED REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 0 04/18/23 ISSUED FOR CONSTRUCTION CA200050 ARCADIA ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 NMB KKP 406879 ENLARGED SITE PLAN C-3 6'4'2'0 5'10' 3/16"=1'-0" ENLARGED SITE PLAN EXISTING TREE (TYP) EXISTING ASPHALT PARKING LOT EXISTING CONCRETE SIDEWALK EXISTING PROPERTY LINE EXISTING UTILITY TRANSFORMER 1A EXISTING PARKING STRIPE (TYP) 1 1B2 4 EXISTING UNDERGROUND ELECTRIC LINE (TYP) EXISTING UNDERGROUND GAS LINE (TYP)EXISTING UNDERGROUND FIBER OPTIC LINE (TYP) EXISTING FIBEROPTIC PEDESTAL (TYP) EXISTING FIBER OPTIC VAULT (TYP) EXISTING IRRIGATION CONTROL VALVE (TYP) EXISTING OVERHEAD ELECTRIC LINE (TYP) EXISTING SETBACK LINE EXISTING UTILITY POLE EXISTING BUSH (TYP) EXISTING CONCRETE CURB WITH GUTTER (TYP) LY N R O S E S T EXISTING LIGHT POLE (TYP) 2 EXISTING STUB OUT LOCATION FOR FUTURE DISPENSER EXISTING BUSH (TYP) NOTES 1.SOD PLANTED IN THE FALL MUST ESTABLISH ITS ROOTS BEFORE THE FIRST WINTER FROST. DETERMINE WHEN THE FIRST FROST USUALLY OCCURS, AND PLANT THE SOD NO LATER THAN ONE MONTH BEFORE THE FIRST FROST. IF THE CONSTRUCTION IS FINISHED LATER THAN ONE MONTH BEFORE THE FIRST FROST, USE STRAW UNTIL SOD CAN BE INSTALLED. 2.THE CONTRACTOR SHALL RETURN SIDEWALKS, LANDSCAPING, PLANTERS, IRRIGATION SYSTEMS, AND ANY OTHER FACILITIES DISTURBED BY THE WORK TO THE SAME OR BETTER CONDITION THAN EXISTED PRIOR TO THE COMMENCEMENT OF THE WORK. SEE ENLARGED EQUIPMENT LAYOUT SHEET C-4 PROPOSED PLATFORM (TYP) EXISTING BTC DISPENSER TO REMAIN UNCHANGED PROPOSED DISPENSER (TYP OF 2) A D-1 PROPOSED DISPENSER DISPENSER NUMBER 350 KW CABLE TYPE 1*CCS 1**CCS 1B 2 *SHARED 350KW OUTPUT **DEDICATED 350KW OUTPUT EXISTING DISPENSER DISPENSER NUMBER 350 KW LEVEL 2 CABLE TYPE 1*CCS/CHAdeMO 1 J1772 1A 4 *SHARED 350KW OUTPUT C80849 4/18/2023 3/31/25 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 0 04/18/23 ISSUED FOR CONSTRUCTION CA200050 ARCADIA ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 NMB KKP 406879 ENLARGED EQUIPMENT LAYOUT C-4 12"6"0 1'2'3' 3/4"=1'-0" ENLARGED PROPOSED EQUIPMENT LAYOUT INCOMING 1 2 EXISTING 10'-5" EX I S T I N G 1 1 ' - 1 1 " 1' - 1 " 5'-1" (TYP) EXISTING CONCRETE PAD EXISTING SINGLE GATE (TYP) EXISTING GFCI RECEPTACLE IN WEATHERPROOF ENCLOSURE EXISTING FENCE POST (TYP) EXISTING EQUIPMENT ENCLOSURE EXISTING 23'-4" EXISTING SWITCHBOARD ASSEMBLY B D-1 PROPOSED POWER UNIT (TYP OF 2) PROPOSED PLATFORM (TYP) EXISTING CONDUITS TO BE REUSED WITH NEW POWER UNITS (TYP) (SEE E1-1 & E-1.2) 3'-6" 2' - 3 " 3' - 6 " EX I S T I N G 1 4 ' - 4 " - C-4.1 C80849 4/18/2023 3/31/25 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 0 04/18/23 ISSUED FOR CONSTRUCTION CA200050 ARCADIA ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 NMB KKP 406879 W-BEAM DETAIL C-4.1 12"9"6"3"0 1' 1 1/2"=1'-0" W-BEAM DIMENSION DETAIL PROPOSED W6x12 (TYP) PROPOSED 1/4" DIAMOND PLATE 9' - 5 " 9' - 9 " 2' - 3 " 2' - 5 " 1' - 3 " 2' - 5 " 1' - 1 " 9'-5" 8'-9" 2'-5" 6" (T Y P ) 4'-4" (TYP) 2'-0" (TYP) 3' - 2 " (T Y P ) C80849 4/18/2023 3/31/25 FRO N T REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 0 04/18/23 ISSUED FOR CONSTRUCTION CA200050 ARCADIA ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 NMB KKP 406879 ELECTRICAL PLAN E-1 6'4'2'0 5'10' 3/16"=1'-0" ELECTRICAL PLAN EXISTING TREE (TYP) EXISTING ASPHALT PARKING LOT EXISTING CONCRETE SIDEWALK EXISTING PROPERTY LINE EXISTING UTILITY TRANSFORMER 1A 1 1B 2 4 EXISTING BOLLARD (TYP) EXISTING UNDERGROUND ELECTRIC LINE (TYP) EXISTING UNDERGROUND GAS LINE (TYP)EXISTING UNDERGROUND FIBER OPTIC LINE (TYP) EXISTING FIBEROPTIC PEDESTAL (TYP) EXISTING FIBER OPTIC VAULT (TYP) EXISTING IRRIGATION CONTROL VALVE (TYP) EXISTING OVERHEAD ELECTRIC LINE (TYP) EXISTING SETBACK LINE EXISTING UTILITY POLE EXISTING BUSH (TYP) EXISTING CONCRETE CURB WITH GUTTER (TYP) LY N R O S E S T EXISTING LIGHT POLE (TYP) 2 EXISTING STUB OUT LOCATION FOR FUTURE DISPENSER EXISTING BUSH (TYP) PROPOSED PLATFORM (TYP) PROPOSED DC WIRE ROUTING, SEE SHEET E-1.2 PROPOSED AC WIRE ROUTING, SEE SHEET E-1.1 QTY 22 3 4 QTY 2 3 3A 4 EXISTING LEVEL 2 CHARGER TO REMAIN UNCHANGED EXISTING BTC DISPENSER TO REMAIN UNCHANGED NOTES 1.EXISTING CONDUIT ROUTING IS DIAGRAMMATICALLY SHOWN ON PLANS AND ARE ONLY APPROXIMATIONS. THE EXACT LOCATION AND ROUTING PATHS SHALL BE FIELD VERIFIED AND INSTALLED PER JURISDICTIONAL REQUIREMENTS. 2.ALL ELECTRICAL WORK AND RELATED ACTIVITIES PERFORMED ONSITE SHALL BE DONE IN ACCORDANCE WITH CALIFORNIA ELECTRICAL CODE (CEC) STANDARDS BEING ENFORCED BY ALL APPLICABLE JURISDICTIONAL REQUIREMENTS AT TIME OF CONSTRUCTION. 3.REFER TO CONDUIT AND WIRE SCHEDULE ON E-2 FOR CONDUIT AND WIRE REQUIREMENTS. -= SEE NOTE 3 FOR REFERENCE 3 3A 4 C80849 4/18/2023 3/31/25 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 0 04/18/23 ISSUED FOR CONSTRUCTION CA200050 ARCADIA ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 NMB KKP 406879 ELECTRICAL PLAN AC WIRE ROUTING E-1.1 12"9"6"3"0 1'2' 1"=1'-0" ELECTRICAL PLAN INCOMING 1 2 NOTES 1.EXISTING CONDUIT ROUTING IS DIAGRAMMATICALLY SHOWN ON PLANS AND ARE ONLY APPROXIMATIONS. THE EXACT LOCATION AND ROUTING PATHS SHALL BE FIELD VERIFIED AND INSTALLED PER JURISDICTIONAL REQUIREMENTS. 2.ALL ELECTRICAL WORK AND RELATED ACTIVITIES PERFORMED ONSITE SHALL BE DONE IN ACCORDANCE WITH CALIFORNIA ELECTRICAL CODE (CEC) STANDARDS BEING ENFORCED BY ALL APPLICABLE JURISDICTIONAL REQUIREMENTS AT TIME OF CONSTRUCTION. 3.REFER TO CONDUIT AND WIRE SCHEDULE ON E-2 FOR CONDUIT AND WIRE REQUIREMENTS. **AC CONDUCTORS: 16 FEET IS ADDED TO THE HORIZONTAL RUN LENGTH TO ACCOUNT FOR BURIED DEPTH. AC POWER UNIT LENGTHS OLD POWER UNIT NUMBER LINEAR LENGTH SWBD TO POWER UNIT (FT) NEW POWER UNIT NUMBER **ESTIMATED LENGTH (FT) 21 37 11 27 9 25 FUTURE 20 36 1 1 2 3 2 (SEE SHEET E-2 FOR WIRE CONFIGURATION) C80849 4/18/2023 3/31/25 FRO N T REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 0 04/18/23 ISSUED FOR CONSTRUCTION CA200050 ARCADIA ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 NMB KKP 406879 ELECTRICAL PLAN DC WIRE ROUTING E-1.2 4'2'0 4'8' 1/4"=1'-0" ELECTRICAL PLAN 1A 1 1B2 4 2 NOTES 1.EXISTING CONDUIT ROUTING IS DIAGRAMMATICALLY SHOWN ON PLANS AND ARE ONLY APPROXIMATIONS. THE EXACT LOCATION AND ROUTING PATHS SHALL BE FIELD VERIFIED AND INSTALLED PER JURISDICTIONAL REQUIREMENTS. 2.ALL ELECTRICAL WORK AND RELATED ACTIVITIES PERFORMED ONSITE SHALL BE DONE IN ACCORDANCE WITH CALIFORNIA ELECTRICAL CODE (CEC) STANDARDS BEING ENFORCED BY ALL APPLICABLE JURISDICTIONAL REQUIREMENTS AT TIME OF CONSTRUCTION. 3.REFER TO CONDUIT AND WIRE SCHEDULE ON E-2 FOR CONDUIT AND WIRE REQUIREMENTS. 4.LENGTHS SHOWN ALSO APPLY TO COMMUNICATIONS AND AUXILIARY CIRCUITS BETWEEN POWER UNIT AND DISPENSER. ***DC CONDUCTORS: 22 FEET IS ADDED TO THE HORIZONTAL RUN LENGTH TO ACCOUNT FOR BURIED DEPTH. DC POWER UNIT LENGTHS NEW POWER UNIT NUMBER LINEAR LENGTH (FT)DISPENSER ***ESTIMATED LENGTH (FT) 44 66 54 76 68 90 1 1A 1B 2 2 (SEE SHEET E-2 FOR WIRE CONFIGURATION) C80849 4/18/2023 3/31/25 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 0 04/18/23 ISSUED FOR CONSTRUCTION CA200050 ARCADIA ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 NMB KKP 406879 SINGLE LINE DIAGRAM E-2 M EXISTING UTILITY GROUND (PER UTILITY) 1600AF 1200AT W/RELT INCOMING/ METERING SECTION 50 A 3P 1 EXISTING 1200A GE SWITCHBOARD 277/480V, 3ɸ, 4W 65KAIC WITH GROUND FAULT PROTECTIONEXISTING UTILITY TRANSFORMER , 480/277V, 3ɸ, 4W 750KVA GR N D NE U T 40 0 A F 35 0 A T 10 0 A MA I N 20 A 1P XFMR 30KVA 480 120/208V MAIN BREAKER SECTION 277/480V DISTRIBUTION SECTION 120/208V DISTRIBUTION SECTION 30 A 1P 30 A 1P 30 A 1P 40 A 2P FUTURE BESS EQUIPMENT SP A C E SP A C E EXISTING GFCI RECEPTACLE EXISTING LEVEL 2 CHARGER *1600A BUS* EXISTING GROUNDING ELECTRODE SYSTEM 60 0 A F 60 0 A T 3P 360 KW POWER UNIT #2 60 0 A F 60 0 A T 3P EXISTING CHAdeMO DISPENSER 1A 360 KW POWER UNIT #1 DISPENSER 1B A/B E-3 2 SEE NOTE 1 3 4 SEE NOTE 2SEE NOTE 2 3 3A 4 SEE NOTE 3 DISPENSER 2 1.CONTRACTOR TO REPLACE EXISTING POWER UNIT 300A BREAKER(S) WHEN NECESSARY TO INSTALL (2) NEW 600A BREAKERS. 2.CONTRACTOR TO REMOVE EXISTING CONDUCTORS FROM EXISTING SWITCHBOARD TO NEW GEN IV EVSE POWER UNITS. CONTRACTOR TO RE-USE EXISTING CONDUITS AND NEW PLATFORM TO INSTALL NEW CONDUCTORS TO NEW POWER UNITS. 3.EXISTING 120V AUXILIARY POWER CONDUIT AND CONDUCTORS FROM SWITCHBOARD TO DISPENSER TO REMAIN. NOTES LOAD SUMMARY FLA QTY TOTAL FLA 360KW POWER UNIT 465 2 930 BTC CONDUIT AND WIRING SCHEDULE FROM TO CONFIGURATION UTILITY TRANSFORMER EXISTING SWITCHBOARD EXISTING EXISTING SWITCHBOARD PROPOSED POWER UNIT (EV CHARGER) (3) 350 MCM CU (XHHW-2) + (1) 1/0 CU (THWN-2) EGC IN EACH OF (2) 3" EXISTING CONDUITS PROPOSED POWER UNIT (EV CHARGER) PROPOSED DC DISPENSER (POST) DC POWER (2) 350 MCM AL (XHHW-2) 1KV+ (1) 1/0 CU (THWN-2) EGC IN (1) 2 1/2" EXISTING CONDUIT PROPOSED POWER UNIT (EV CHARGER) PROPOSED DC DISPENSER (POST) DC POWER + AUXILIARY POWER (2) 350 MCM AL (XHHW-2) 1KV+ (1) 1/0 CU (THWN-2) EGC + (2) #10 AWG CU (XHHW-2) 1KV+ (1) #10 AWG CU (THWN-2) EGC IN (1) 2 1/2" EXISTING CONDUIT PROPOSED POWER UNIT (EV CHARGER) PROPOSED DC DISPENSER (POST) COMMUNICATION (1) 6 STRAND, 62.5UM OR OM3 BUFFERED I/O MM FIBER (ST/ST CONN) + (1) 2 CONDUCTOR #16 AWG (TW/SH PAIR) + (1) CAT 6 CABLE W/RJ45 CONNECTORS IN (1) 1 1/2" EXISTING CONDUIT 1 2 3 3A 4 TOTAL LOAD = 930A EXISTING AUXILIARY POWER 3A C80849 4/18/2023 3/31/25 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 0 04/18/23 ISSUED FOR CONSTRUCTION CA200050 ARCADIA ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 NMB KKP 406879 ELECTRICAL DETAILS E-3 1.FOR SETUP ASSISTANCE SEE ABB DOCUMENT 1SDH002039A1002. 2.ALL BREAKERS SUPPLIED WITH PADLOCKING PROVISIONS. 3.REFER TO SWITCHBOARD FOR TRIP UNIT TYPE. NOTES THERMAL TRIP (I1) = MAX 600A MAGNETIC TRIP (I3) = MIN 3000A MAX MIN MID MAX MIN MID I3 MAX MED MIN MAX MED MINTMA I1 (40°C)3000A 600A IN = 600A Ekip Hi-Touch LSI ABB In = 600A LONG TIME: PICKUP (I1):1.00 X In (600A) DELAY (t1):5 DELAY BAND (t):EXTREMELY INVERSE SHORT TIME: PICKUP (t):3.5 x In (2100A) DELAY (I2):0.07 DELAY BAND (t2):I^2T OFF INSTANTANEOUS: PICKUP (I3):4.7 x In (2820A) A B CNO SCALENO SCALENO SCALETMAX XT BRANCH BREAKER SETTINGS ENTELLIGUARD TU TRIP UNIT DETAIL LONG TIME: CURVE: CB PICKUP: 1.00 x In BAND: C9 SHORT TIME: PICKUP: 3.5 x LT BAND: 4 SLOPE: OFF INST: PICKUP: 4.5 x In GTP0600U0616 600A GE SPECTRA RMS SGLC BREAKER DETAIL 1.FOR SETUP ASSISTANCE SEE SECTION 2 OF THE GE SPECTRA® RMS MOLDED CASE CIRCUIT BREAKER WITH MICROENTELLIGUARD TRIP UNIT USER MANUAL: GEH-702. 2.ALL BREAKERS SUPPLIED WITH PADLOCKING PROVISIONS. 3.REFER TO SWITCHBOARD FOR TRIP UNIT TYPE. NOTES GTP0600U0616 600A LONG TIME: PICKUP:FIXED BAND: FIXED SJORT TIME: PICKUP: FIXED BAND: FIXED INST: PICKUP: MIN MAX 5 4 3 2MIN LONG TIME: CURVE: I2T PICKUP: 1.00 x In BAND: C7 SHORT TIME: PICKUP: 3.5 x LT BAND: 5 SLOPE: OFF INST: PICKUP 15 x In RELT INST: PICKUP: 1.5 x In GF SUM: PICKUP: 0.32 x CT BAND: 3 SLOPE: OFF LONG TIME CURVE: CB LONG TIME PICKUP: 1.00 xln BAND: C3 1200A SHORT TIME PICKUP: 3.5 xLT BAND: 5 SLOPE: OFF INST PICKUP: 15 RELT INST PICKUP: 2.5 xln GF SUM PICKUP: 0.32 xCT BAND: 3 SLOPE: I2T xln ENTELLIGUARD TU TRIP UNIT GTP1200U1232 1200A LOCKOUT PUSH TO RESET STATUS 1.FOR SET UP ASSISTANCE SEE SECTION 6 OF THE GE ENTELLIGUARD* USER MANUAL: DEH-4567. 2.RELT FUNCTIONS AS THE ENERGY REDUCING MAINTENANCE SWITCH. 3.MAIN BREAKER IS 100% RATED. NOTES C80849 4/18/2023 3/31/25 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 0 04/18/23 ISSUED FOR CONSTRUCTION CA200050 ARCADIA ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 NMB KKP 406879 EQUIPMENT DETAILS D-1 DNO SCALE BANO SCALE ENO SCALE CNO SCALE FNO SCALE NO SCALE 1.OPERABLE PARTS OF DISPENSER TO FRONT OF CURB SHALL BE 10" MAX. 2.OPERABLE PARTS OF DISPENSER SHALL NOT EXCEED 54" ABOVE PARKING SURFACE WHEN DISPENSER IS ON A CURB. 3.FRONT OF DISPENSER BASE PLATE TO LINE UP WITH FACE OF EXISTING DISPENSER SO ADA REACH RANGE IS MAINTAINED. THIS SHOULD BE AROUND 12". NOTES DISPENSER FOOTING DETAIL DISPENSER C.L. PLAN FRONT SIDE CAR SIDE EXISTING ASPHALT GRADE 98 . 2 4 " 48 " M A X CAR SIDE PROPOSED PLINTH EXISTING CONCRETE E - EXISTING FOOTING 3'-6" 2' - 6 " NO T E 3 EXISTING ASPHALT GRADE 6"PROPOSED CONCRETE CUTOUT E - POWER UNIT PLATFORM 1.GALVANIZED SHEET METAL TO BE WELDED BETWEEN W BEAMS TO COVER OPENING. THIS MAY BE OMITTED WHERE A RACEWAY IS PROPOSED. 2.MINIMUM CONCRETE EDGE DISTANCE FOR PROPOSED ANCHORS SHALL BE 6". 3.W-BEAMS TO RUN UNDER ENTIRE LENGTH OF POWER UNITS. 4.ALLOWED TO USE EFFECTIVE EMBEDMENT OF 2" WHEN NOT NEAR POWER UNIT. SPACING MAY BE INCREASED TO 8' MAX WHEN NOT NEAR POWER UNIT. NOTES 1/2” DIA. HILTI HAS-R 304/316 SS ANCHOR WITH HILTI HIT-RE 500 V3 EPOXY & MINIMUM EFFECTIVE EMBEDMENT OF 4” OR ENGINEER APPROVED EQUAL. (ESR-3814) (TYP @ 2'-6" O.C.) (WITHIN 1' OF POWER UNIT) (NOTE 4) NOTE 1 HOT DIPPED GALVANIZED W6X12 (TYP) SECTION 1 1 - 1" SEE SITE PLAN 6" (TYP) 7/ 8 " (T Y P ) POWER UNIT ANCHORAGE (TYP) EXISTING FOOTING POWER UNIT FOOTER 2'-6" MAX NOTE 1 NOTE 3 DIAMOND PLATE AND GALVANIZED STEEL CONNECTION DETAIL W6x12 (TYP) NOTES: 1.1/4" DIAMOND PLATE SHALL HAVE A MINIMUM 36 KSI YIELD STRENGTH, HOT DIP GALVANIZED, AND IN ACCORDANCE TO ASTM A786. 2.EDGE OF DIAMOND PLATE SHALL BE FLUSH WITH EDGE OF PROPOSED W BEAM. 3.NON-SHRINK GROUT SHALL BE SET AS NEEDED AFTER W BEAMS ARE LEVELED TO ENSURE CONTINUOUS BEARING SURFACE ALONG CHANNEL LENGTH. NON-SHRINK GROUT SHALL ARCHIVE FULL COMPRESSIVE STRENGTH PER MANUFACTURER'S SPECIFICATION PRIOR TO INSTALLATION OF PROPOSED EQUIPMENT. 4.NO DIAMOND PLATE IS PROPOSED BELOW DISPENSERS. SEE SITE PLAN FOR DIAMOND PLATE AT POWER UNIT. CONTRACTOR TO FIELD SCAN FLOOR SLAB FOR REINFORCEMENT, ENSURE 1" MINIMUM GAP BETWEEN ALL ANCHORAGE AND EXISTING REINFORCEMENT. CUTTING AND DAMAGING EXISTING REBAR IS PROHIBITED 1" ADHERED CSPE BASE FLASHING (TYP) 1/4" DIA ASTM A307 HDG BOLT W/ NUT AND WASHER (@12" O.C.) EXISTING CONCRETE FOUNDATION 2' - 5 " F - TOP VIEW FRONT VIEWLEFT SIDE VIEW RIGHT SIDE VIEW WEIGHT = 1655 LBS 2'-6" 3' - 4 . 5 " 2'-9"4"2'-6"3'-1" 4" 7' - 9 " 2" 2' - 8 " 2" 1' - 9 " 1'-0" 1' - 0 " 1'-8 1/2" POWER UNIT DETAIL PROPOSED PLATFORM EXISTING CONCRETE PAD F - DETAIL NOT USED B D-2 DISPENSER PLINTH 1.MINIMUM CONCRETE EDGE DISTANCE FOR PROPOSED ANCHORS SHALL BE 6". 2.EXISTING DISPENSER CONDUIT WINDOW. 3.TOP PLATE OF PLINTH IS TO SIT FLUSH ON TOP OF EXISTING CONCRETE. TOP LAYER OF REBAR MAY BE ENCOUNTERED AND CUT. EXISTING SECOND ROW OF REBAR IS NOT TO BE MODIFIED IN ANY FASHION. NOTES 18.5" 1/2" DIA. HILTI KWIK BOLT TZ2 SS 304/316 MECHANICAL ANCHOR WITH MINIMUM EFFECTIVE EMBEDMENT OF 3 1/4" OR ENGINEER APPROVED EQUAL. (ESR-4266)(TYP OF 6 PER PLINTH) HOT DIPPED GALVANIZED MANUFACTURED PLINTH (TYP) DISPENSER FOOTER NOTE 2 FRONT OF DISPENSER DISPENSER ANCHORAGE (TYP) EXISTING FOOTING A D-2 NOTE 3 14 . 1 7 5 " C80849 4/18/2023 3/31/25 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 0 04/18/23 ISSUED FOR CONSTRUCTION CA200050 ARCADIA ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 NMB KKP 406879 EQUIPMENT DETAILS D-2 DNO SCALE ENO SCALE FNO SCALE B CNO SCALEANO SCALE DETAIL NOT USED NO SCALE DETAIL NOT USED DETAIL NOT USED POWER UNIT ANCHORAGE DETAIL INSTALLATION FOOTER 5/8" DIA ASTM A325 HDG BOLT W/ NUT AND WASHER, (TYP, TOTAL OF 4) OPEN AREA 1'-5"x1'-7" 1'-8" 2' - 5 " 3" 1' - 7 " 1'-5" 1" 5" 2'-5" 2' - 8 " 3" 1.CONTRACTOR TO FIELD VERIFY THE ANCHOR SPACING PER MANUFACTURER'S INSTALLATION MANUAL. NOTE 5/8" DIA. ASTM A325 HDG BOLT W/ NUT AND WASHER (TYP, TOTAL OF 6) DISPENSER ANCHORAGE DETAIL 12.68"4.405" 1. 4 " 7"8" 9.84" CONDUIT AREA 1.CONTRACTOR TO FIELD VERIFY THE ANCHOR SPACING PER MANUFACTURER'S INSTALLATION MANUAL. NOTE 6.34"6.34" BOTTOM VIEW OF PLINTH 1.ANCHOR HOLES NOT NEAR OPEN AREA HAVE 1.18" HOLES ABOVE THEM FOR INSTALLATION ACCESS. CONTRACTOR TO INSTALL PLUGS PROVIDED BY MANUFACTURER AFTER INSTALLATION IS COMPLETE. 2.CUT IN CONCRETE IS ALLOWED TO BE UP TO 1/8" AWAY FROM EDGE OF PLINTH WHICH IS INSERTED INTO THE CONCRETE. NOTES 14.175" 6" 2" 18.5" 17.5" 14 . 1 7 5 " 13 . 1 7 5 " 15" 5" (T Y P ) OPEN AREA 10"x5" SECTION 1 1 - 2" FACE OF DISPENSER C80849 4/18/2023 3/31/25 360kW High Power DC Charger INSTALLATION AND USER’S MANUAL BTCPOWER, INC. 1719 S. GRAND AVE. SANTA ANA, CA 92705 WWW.BTCPOWER.COM This document is a Property of BTCPower Inc. and shall not be copied, reproduced, or used as the basis for sale or manufacture of apparatus without written permission. 23-Sep-22 Rev D 360kW High Power DC Charger INSTALLATION AND USER’S MANUAL Page 12 of 89 EQUIPMENT DESCRIPTION LOCATION OF LABELS Tower Dispenser This document is a Property of BTCPower Inc. and shall not be copied, reproduced, or used as the basis for sale or manufacture of apparatus without written permission. 23-Sep-22 Rev D 360kW High Power DC Charger INSTALLATION AND USER’S MANUAL Page 13 of 89 SYSTEM SPECIFICATION 4. System Specification 4.1. DCFC Power Unit AC to DC Power Converter Specification SKU: HPCT2-360-480-2 PARAMETER HPCT2-360-480-2 AC Input Input Voltage Range 480 VAC, 3 Phase, +10% / -15% Input Frequency Range 47 – 63 Hz Input Current @ 480 VAC 465 A Panel Breaker 600A Power Factor > 0.99 full load Total Harmonic Distortion < 5% Efficiency at Full Load > 94% SCCR 65kA AC Output Number of Outputs 2 Voltage 480VAC, Split Phase Current 6A DC Output Output Voltage Range 200 – 950 VDC Number Of Outputs 2 Max Output Current (per output) 500A Maximum Output Power 360 kW Minimum Output Current 5A Output Ripple Current < 15 Ap–p (Bandwidth 1 kHz) Protection Over Temperature Self–protected and latched Output Over Voltage Output Shutdown and Latched Output Overload Output Shutdown and Latched CAN Communication Loss 1 sec Shutdown Upon Loss of Connection Reverse Feed Back Feed Protection Safety Standards Isolation UL 2202 EMC Standards Harmonics IEC 61000-3-12 Emissions FCC and IEC 61851-21-2 Immunity UL 2231-2 Environment Conditions Operating Temperature Range -30°C to +50°C Operating Altitude 2,000 meters Humidity 95% Non-Condensing Mechanical Characteristics Dimensions 30” W x 34.5” D x 93” H Weight 1655 lbs Enclosure IK Rating IK 10 Enclosure IP Rating IP 54 (NEMA 3R) *Specifications are subject to change, without prior notice. This document is a Property of BTCPower Inc. and shall not be copied, reproduced, or used as the basis for sale or manufacture of apparatus without written permission. 23-Sep-22 Rev D 360kW High Power DC Charger INSTALLATION AND USER’S MANUAL Page 26 of 89 INSTALLATION 7.2. Mounting Procedures 7.2.1. Clearance Around the Unit Clearance surrounding the unit must be considered for proper ventilation and service accessibility. Refer to the installation drawings as illustrated below. Power Unit / Tower Installation Drawing This document is a Property of BTCPower Inc. and shall not be copied, reproduced, or used as the basis for sale or manufacture of apparatus without written permission. 23-Sep-22 Rev D 360kW High Power DC Charger INSTALLATION AND USER’S MANUAL Page 27 of 89 INSTALLATION This document is a Property of BTCPower Inc. and shall not be copied, reproduced, or used as the basis for sale or manufacture of apparatus without written permission. 23-Sep-22 Rev D 360kW High Power DC Charger INSTALLATION AND USER’S MANUAL Page 29 of 89 INSTALLATION Power Unit / Tower Footer Drawing The illustration below shows the drilling layout for the Power Unit / Tower. Four (4) points are needed to fix the unit on the concrete pad. The front mounting holes MUST be used, but for the rear, either set of the back mounting holes may be used. The conduit entry to the unit is also shown. Base foundation template for alignment and hole location is available in .step or .dxf files upon request. NOTE The bottom of the tower needs to be sealed to the ground. This document is a Property of BTCPower Inc. and shall not be copied, reproduced, or used as the basis for sale or manufacture of apparatus without written permission. 23-Sep-22 Rev D 360kW High Power DC Charger INSTALLATION AND USER’S MANUAL Page 14 of 89 SYSTEM SPECIFICATION 4.2. DCFC Dispenser High Power Dispenser Specification SKU: HPCD6-500-05-005 PARAMETER DISPENSER 500A Rated AC Input Auxiliary Input Voltage 480 VAC, Split Phase, +/-10% (L1, L2, Ground) Auxiliary Input Current 6A @ 480 VAC Input Frequency Range 60 Hz ± 10 % DC Input Input Voltage Range 200 - 950 V Input Current Range 5 – 500 A DC Output CCS Configuration Maximum DC Output Current CCS, continuous 500 A Environment Conditions Operating Temperature Range -30°C to +50°C Operating Altitude 2,000 m Humidity 5-95% non-condensing Mechanical Characteristics Enclosure IK Rating IK 10 Enclosure IP Rating IP 54 (NEMA 3R) Dimensions Footer: 22” (W) x 16.8” (D) x 96.8” (H) Overall: 31.5” (W) x 18.7” (D) x 96.8” (H) Weight 551 lbs *Specifications are subject to change, without prior notice. This document is a Property of BTCPower Inc. and shall not be copied, reproduced, or used as the basis for sale or manufacture of apparatus without written permission. 23-Sep-22 Rev D 360kW High Power DC Charger INSTALLATION AND USER’S MANUAL Page 28 of 89 INSTALLATION Dispenser Installation Drawing 7.2.2. Tower and Dispenser Mounting Both the Tower and Dispenser must be fixed on a concrete pad. The Tower requires four (4) ½" x 4" (P/N RHPA-3830) concrete expansion bolts, and the Dispenser requires six (6) ½" x 4" (P/N RHPA- 3830) concrete expansion bolts or as determined appropriate by the structural engineer in- charge. Make sure to check local codes for compliance. This document is a Property of BTCPower Inc. and shall not be copied, reproduced, or used as the basis for sale or manufacture of apparatus without written permission. 23-Sep-22 Rev D 360kW High Power DC Charger INSTALLATION AND USER’S MANUAL Page 30 of 89 INSTALLATION Dispenser Footer Drawing The illustration below shows the drilling layout for the Dispenser. Six (6) points are needed to fix the unit on the concrete pad. The conduit entry to the unit is also shown. Base foundation template for alignment and hole location is available in .step or .dxf files upon request. NOTE The bottom of the dispenser needs to be sealed to the ground. BLACK & VEATCH CORPORATION 11401 LAMAR AVENUE, OVERLAND PARK, KANSAS 66211 Date:March 24, 2023 Project Designation Generic Calculation Client Name:Electrify America, LLC. Site Number:CA200050 Site Name:Arcadia Project Name:Installation of Electric Vehicle Charging Equipment Project Number:406879 Site Data:Albertsons 0561, 298 E. Live Oak Ave., Arcadia, CA 91006 Latitude 34° 06' 25.80'', Longitude -118° 01' 27.80'' Structural analysis prepared by: Phattharawat Nakkhum / Thapakorn Lawanwilaiwong Respectfully submitted by: Noel Z. Herrera, S.E. Structural Engineer Non-Tower Structural Analysis Report - version 1.1 This analysis has been performed in accordance with the Applicable Codes, Standard references and design criteria as listed in Section 2 - Analysis Criteria. STRUCTURAL DESIGN REPORT Black & Veatch Corporation is pleased to submit this “Structural Design Report” to determine the structural integrity of the above-mentioned structure. The purpose of the analysis is to determine acceptability of the proposed equipment anchorage and existing foundation design including the proposed design sketches as outlined in the attached drawings, Appendix C. Based on our analysis we have determined the installation of equipment anchorage and foundation design, to be: Sufficient CapacityProposed Equipment Anchorage and Existing Foundation S6199 3/31/25 Electrify America, LLC. / CA200050 - Arcadia 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Equipment Configurations 3) ANALYSIS PROCEDURE Table 2 - Documents Provided 3.1) Analysis Method 3.2) Assumptions, Disclaimers, and Notes 4) ANALYSIS RESULTS Table 3 - Component Stresses vs. Capacity 4.2) Structural Design of Proposed 360kW BTC Power Unit Platform Anchorage Table 4 - Component Stresses vs. Capacity 4.3) Recommendations 5) APPENDIX A Loading Calculations & Additional Calculations 6) APPENDIX B Attachments 7) APPENDIX C Structural Detail Sketches TABLE OF CONTENTS March 24, 2023 Generic Calculation 4.1) Structural Design of Proposed 350kW BTC Dispenser Plinth Anchorage on Existing Foundation 1) INTRODUCTION 2) ANALYSIS CRITERIA Code and Standard References: A. California Building Code, CBC 2022 B. International Building Code, IBC 2021 C. American Society of Civil Engineers, ASCE 7-16 D. American Concrete Institute, ACI 318-19 Design Criteria based on: Risk Category:Seismic Importance Factor, Ie: Wind Speed: mph Seismic SDS:g Exposure Category:Seismic Design Category: Topographic Factor: Table 1 - Equipment Configurations (P) (P) Notes: (P) = Proposed Equipment. EA 0.0 This site is a generic calculation of the proposed equipment anchorage and existing foundation for electric vehicle charging stations. California Building Code, CBC 2022 Concrete Pad BTC Power Concrete Foundation Manufacturer BTC Power 2 Qt’y 2 Carrier Elev. (ft)Location C 1.00 Electrify America, LLC. / CA200050 - Arcadia Generic Calculation March 24, 2023 Equipment Model Gen IV HPCD6-500-05-005 Gen IV HPCT2-360-480-2 Type Dispenser Power Unit II 1.00 115 2.000 E 3) ANALYSIS PROCEDURE Table 2 - Documents Provided 3.1) Analysis Method 3.2) Assumptions, Disclaimers, and Notes 1) 2) 3) 4) This analysis was performed under the assumption that all information provided to Black & Veatch is current and correct. This is to include site data, equipment loading and geotechnical data. If any of this information is not current and correct, this report should be considered obsolete and further analysis will be required. This certification assumes that all structural members are in good condition. Contractor shall inspect the condition of all relevant members and connectors and report any perceived deficiencies to the engineer prior to installation of any new equipment. This anchorage and foundation design calculations are conservatively based upon maximum anticipated wind and seismic forces. See Section 2 for generic design criteria. All other assumptions as stated within report. The contractor shall be responsible for the means and methods of construction. It is contractor’s responsibility to provide necessary intermediate or temporary support during construction. This analysis may be affected if any assumptions are not valid or have been made in error. Black & Veatch Corp. should be notified to determine the effect on the structural integrity of the structure. Document Reference Construction Drawings (Rev. 0)Black & Veatch Corp. (03/29/2023)Black & Veatch Electrify America, LLC. / CA200050 - Arcadia March 24, 2023 Source Generic Calculation A tool internally developed, using Microsoft Excel, by Black & Veatch Corp. was used to calculate wind and seismic loading on the equipment and platform for various load cases. 4) ANALYSIS RESULTS 4.1) Structural Design of Proposed 350kW BTC Dispenser Plinth Anchorage on Existing Foundation Table 3 - Component Stresses vs. Capacity Notes: 4.2) Structural Design of Proposed 360kW BTC Power Unit Platform Anchorage Table 4 - Component Stresses vs. Capacity Notes: 4.3) Recommendations 1 Structure Rating (max from all components) = 66.0% Note Component % Capacity Pass / Fail 1/2" dia. Hilti HIT-RE 500 V3 epoxy: Tension 66.0 Pass 1 1 1) See additional documentation in "Appendix A - Loading Calculations & Additional Calculations" for calculations supporting the % capacity consumed. 1/2" dia. Hilti Kwik Bolt TZ2 SS 304 mechanical: Tension 1/2" dia. Hilti Kwik Bolt TZ2 SS 304 mechanical: Shear 1/2" dia. Hilti Kwik Bolt TZ2 SS 304 mechanical: Tension/Shear Foundation: Bearing Pressure This structural design, as shown in the structural sketches, shall be installed per the specifications and details listed in Appendix C. Pass 1/2" dia. Hilti HIT-RE 500 V3 epoxy: Tension/Shear 66.0 Pass 1/2" dia. Hilti HIT-RE 500 V3 epoxy: Shear 34.0 Foundation: Overturning Against Moment Foundation: Sliding Against Moment Foundation: Reinforced Concrete Section Generic Calculation 1) See additional documentation in "Appendix A - Loading Calculations & Additional Calculations" for calculations supporting the % capacity consumed. Note March 24, 2023 % Capacity Pass / Fail Electrify America, LLC. / CA200050 - Arcadia Structure Rating (max from all components) = 80.9% 12.8 Pass 74.6 Pass 32.7 Pass 57.0 Pass 80.9 Pass 69.0 Pass 13.0 Pass Component Electrify America, LLC. / CA200050 - Arcadia March 24, 2023 Loading Calculations & Additional Calculations APPENDIX A Generic Calculation Electrify America, LLC. / CA200050 - Arcadia March 24, 2023 Generic Calculation Structural Design of Proposed 350kW BTC Dispenser Plinth Anchorage on Existing Foundation Electrify America, LLC. / Generic Generic Calculation SEISMIC LOAD CALCULATION The equipment is considered a Non-Structural Component per section 13.3 of ASCE 7-16. Fp = 0.4 ap SDS Wp (1 + 2 z/h) / (Rp/Ip)eq. 13.3-1 = 0.4 x 1.00 x 2.00 (1 + 2 x 0.00) / (2.50 / 1.00) Fp =0.32 Wp Fp = 1.6 SDS Ip Wp eq. 13.3-2 = 1.6 x 2.00 x 1.00 x Wp Fp =3.20 Wp (maximum) Fp = 0.30 SDS Ip Wp eq. 13.3.3 = 0.30 x 2.00 x 1.00 x Wp Fp =0.60 Wp (minimum)(Control) SDS =2.000 g design spectral response at short period (0.2 seconds) (see attached ASCE 7 Hazard Report) SDC = E seismic design Category Ip =1.00 component importance factor per Section 13.1.3 Rp =2.50 component response modification factor per table 13.5-1/13.6-1 ap =1.00 component amplification factor per table 13.5-1/13.6-1 z/h = 0.00 on ground Total Seismic Shear ; h = 8.19 ft (equipment height from ground) w = 1.40 ft (equipment width) l = 1.83 ft (equipment length) Wfull =551 lbs Wempty =551 lbs f Wfull =0.60 x 551 lbs = 330.6 lbs f Wempty =0.60 x 551 lbs = 330.6 lbs Eseis.H = Fp = March 3, 2023 h w I Electrify America, LLC. / Generic WIND LOAD CALCULATION ASCE Section # a. Velocity Pressure, qz Fig. 26-5 qz =0.00256 Kz Kzt Ke Kd V2 Basic Wind Speed, V = 115 mph Eq. 26.10-1 = 0.00256 x 0.85 x 1.00 x 1.00 x 0.85 x 115.00^2 qz = 24.43 psf b. Velocity pressure coefficient, Kz Sec. 26.10.1 Kz =2.01 (z/zg)2/a Exposure Category = C Tab. 26.10-1 = 2.01 (15 / 900^(2/9.5) Kz = 0.85 Height above Ground Level, z = 15 ft a =9.50 zg =900.00 ft Tab. 26.11-1 c. Topographic Factor, Kzt Sec. 26.8 m =0.00 H = 15 ft g =0.00 Hill Shape K1 =0.00 Crest Type K2 =(1 - x / m Lh)Distance Upwind of crest, Lh =0 ft = [1 - 15 / (0.0 x 0)] K2 =0.00 Distance Upwind to Bldg Site, x = 0 ft Fig. 26.8-1 K3 =e (g z / Lh)Kzt =[ 1 + K1 K2 K3 ]2 Eq. 26.8-1 = e^-(0.0 x 15 / 0)= [1 + 0.00 x 0.00 x 0.00]^2 K3 =0.00 Kzt =1.00 d. Ground Elevation Factor, Ke Ke =1.00 Sec. 26.9 e. Wind Directionality Factor, Kd Tab. 26.6-1 Kd =0.85 f. Risk Category II Tab. 1.5-1 g. Gust Effect Factor, G G = 0.85 Sec. 26.11 h. Structure Type / Force Coefficient Cf = 1.65 Min. Fig. 29.3-1 i. Design Wind Pressure,F = 24.43 x 0.85 x 1.65 = 34.26 psf (OK) Min. Req'd : 16 psf j. Total Wind Load On Equipment, Aopening =0.00 s.f. Projected Wind Area on Equipment Af =1.83 x 8.19 - 0 =14.99 s.f. Fwind =34.26 psf x 14.99 s.f. =513.5 lbs March 3, 2023 (8) Solid Sign (1) Solid Freestanding Signs / Walls Flat Terrain Downwind Generic Calculation Electrify America, LLC. / Generic ANCHORAGE DESIGN Input Design Loads: Weight of Equipment:WEmpty =551 lbs WFull =551 lbs Wind Load Govern - (0.9D - W) Vertical Load on Equipment:0.9D =496 lbs Lateral Wind Load on Equipment:W =514 lbs Moment at Base:Mu = W (0.55h) =514 lbs x (0.55 x 8.69 ft x 12 in/ft) =29480 lbs-in Note: If SDC = C or greater, seismic load cases should be included in anchor analysis Seismic Load Govern - {(0.9 - 0.2SDS)D - E} Case 1 - Empty Vertical Load on Equipment:(0.9 - 0.2SDS)D =276 lbs, Empty Seismic Overstrength Factor:W =2.00 Lateral Seismic Load on Equipment with overstrength factor :Eseis.H =661 lbs, Empty Moment at Base:Mu = E (0.67h) =661 lbs x (0.67 x 8.69 ft x 12 in/ft) =46182 lbs-in, Empty Case 2 - Fully loaded Vertical Load on Equipment:(0.9 - 0.2SDS)D =276 lbs, Fully Loaded Lateral Seismic Load on Equipment with overstrength factor :Eseis.H =661 lbs, Fully Loaded Moment at Base:Mu = E (0.67h) =661 lbs x (0.67 x 8.69 ft x 12 in/ft) =46182 lbs-in, Fully Loaded March 3, 2023 Generic Calculation (Additonal 6" to wind and seismic moment calculations to account for plinth embedment depth) www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 350kW BTC Dispenser Plinth Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 1 Thapakorn L. 3/7/2023 Specifier's comments: Wind and Seismic Case - 350kW BTC Dispenser Plinth Anchorage 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - SS 304 1/2 (3 1/4 ) hnom3 Item number: 2210261 KB-TZ2 1/2x4 1/2 SS304 Effective embedment depth: hef,act = 3.250 in., hnom = 3.750 in. Material: AISI 304 Evaluation Service Report: ESR-4266 Issued I Valid: 12/17/2021 | 12/1/2023 Proof: Design Method ACI 318-19 / Mech Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.250 in. Anchor plateR : lx x ly x t = 17.500 in. x 13.175 in. x 0.250 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 3000, fc' = 3,000 psi; h = 8.000 in. Installation: hammer drilled hole, Installation condition: Water saturated Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) Shear load: yes (17.10.6.3 (c)) R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [lb, in.lb] www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 350kW BTC Dispenser Plinth Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 2 Thapakorn L. 3/7/2023 1.1 Load combination and design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Wind Case N = -496; Vx = 0; Vy = 514; Mx = -29,480; My = 0; Mz = 0; no 31 2 Seismic Case N = -276; Vx = 0; Vy = 661; Mx = -46,182; My = 0; Mz = 0; yes 69 Tension Compression1 2 3 4 5 6 x y 2 Load case/Resulting anchor forces Controlling load case: 2 Seismic Case Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 0 110 0 110 2 781 110 0 110 3 1,570 110 0 110 4 0 110 0 110 5 781 110 0 110 6 1,570 110 0 110 max. concrete compressive strain: 0.08 [‰] max. concrete compressive stress: 366 [psi] resulting tension force in (x/y)=(0.000/-3.397): 4,702 [lb] resulting compression force in (x/y)=(0.000/6.069): 4,978 [lb] Anchor forces are calculated based on the assumption of a rigid anchor plate. 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*1,570 8,906 18 OK Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**4,702 6,888 69 OK * highest loaded anchor **anchor group (anchors in tension) www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 350kW BTC Dispenser Plinth Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 3 Thapakorn L. 3/7/2023 3.1 Steel Strength Nsa = ESR value refer to ICC-ES ESR-4266 f Nsa ³ Nua ACI 318-19 Table 17.5.2 Variables Ase,N [in.2]futa [psi] 0.10 120,404 Calculations Nsa [lb] 11,875 Results Nsa [lb]f steel f nonductile f Nsa [lb]Nua [lb] 11,875 0.750 1.000 8,906 1,570 www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 350kW BTC Dispenser Plinth Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 4 Thapakorn L. 3/7/2023 3.2 Concrete Breakout Failure Ncbg = (ANc ANc0)y ec,N y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1b) f Ncbg ³ Nua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ec,N = (1 1 + 2 e' N 3 hef )£ 1.0 ACI 318-19 Eq. (17.6.2.3.1) y ed,N = 0.7 + 0.3 (ca,min1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,mincac , 1.5hefcac)£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables hef [in.]ec1,N [in.]ec2,N [in.]ca,min [in.]y c,N 3.250 0.000 0.854 6.000 1.000 cac [in.]kc l a f' c [psi] 8.000 17 1.000 3,000 Calculations ANc [in.2]ANc0 [in.2]y ec1,N y ec2,N y ed,N y cp,N Nb [lb] 289.32 95.06 1.000 0.851 1.000 1.000 5,455 Results Ncbg [lb]f concrete f seismic f nonductile f Ncbg [lb]Nua [lb] 14,129 0.650 0.750 1.000 6,888 4,702 www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 350kW BTC Dispenser Plinth Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 5 Thapakorn L. 3/7/2023 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*110 5,426 3 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength**661 31,215 3 OK Concrete edge failure in direction y+**661 5,305 13 OK * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa,eq = ESR value refer to ICC-ES ESR-4266 f Vsteel ³ Vua ACI 318-19 Table 17.5.2 Variables Ase,V [in.2]futa [psi]aV,seis 0.10 120,404 1.000 Calculations Vsa,eq [lb] 8,348 Results Vsa,eq [lb]f steel f nonductile f Vsa,eq [lb]Vua [lb] 8,348 0.650 1.000 5,426 110 www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 350kW BTC Dispenser Plinth Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 6 Thapakorn L. 3/7/2023 4.2 Pryout Strength Vcpg = kcp [(ANc ANc0)y ec,N y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1b) f Vcpg ³ Vua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ec,N = (1 1 + 2 e' N 3 hef )£ 1.0 ACI 318-19 Eq. (17.6.2.3.1) y ed,N = 0.7 + 0.3 (ca,min1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,mincac , 1.5hefcac)£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables kcp hef [in.]ec1,N [in.]ec2,N [in.]ca,min [in.] 2 3.250 0.000 0.000 6.000 y c,N cac [in.]kc l a f' c [psi] 1.000 8.000 17 1.000 3,000 Calculations ANc [in.2]ANc0 [in.2]y ec1,N y ec2,N y ed,N y cp,N Nb [lb] 388.52 95.06 1.000 1.000 1.000 1.000 5,455 Results Vcpg [lb]f concrete f seismic f nonductile f Vcpg [lb]Vua [lb] 44,593 0.700 1.000 1.000 31,215 661 www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 7 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 350kW BTC Dispenser Plinth Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 7 Thapakorn L. 3/7/2023 4.3 Concrete edge failure in direction y+ Vcbg = (AVc AVc0)y ec,V y ed,V y c,V y h,V y parallel,V Vb ACI 318-19 Eq. (17.7.2.1b) f Vcbg ³ Vua ACI 318-19 Table 17.5.2 AVc see ACI 318-19, Section 17.7.2.1, Fig. R 17.7.2.1(b) AVc0 = 4.5 c2 a1 ACI 318-19 Eq. (17.7.2.1.3) y ec,V = (1 1 + e' v 1.5ca1 )£ 1.0 ACI 318-19 Eq. (17.7.2.3.1) y ed,V = 0.7 + 0.3(ca21.5ca1)£ 1.0 ACI 318-19 Eq. (17.7.2.4.1b) y h,V = √1.5ca1ha ³ 1.0 ACI 318-19 Eq. (17.7.2.6.1) Vb = (7 (leda)0.2 √da)l a √f' c c1.5 a1 ACI 318-19 Eq. (17.7.2.2.1a) Variables ca1 [in.]ca2 [in.]ecV [in.]y c,V ha [in.] 5.333 6.000 0.000 1.000 8.000 le [in.]l a da [in.]f' c [psi]y parallel,V 3.250 1.000 0.500 3,000 1.000 Calculations AVc [in.2]AVc0 [in.2]y ec,V y ed,V y h,V Vb [lb] 216.00 128.00 1.000 0.925 1.000 4,855 Results Vcbg [lb]f concrete f seismic f nonductile f Vcbg [lb]Vua [lb] 7,579 0.700 1.000 1.000 5,305 661 5 Combined tension and shear loads, per ACI 318-19 section 17.8 bN bV z Utilization bN,V [%]Status 0.683 0.125 5/3 57 OK bNV = bz N + bz V <= 1 www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 8 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 350kW BTC Dispenser Plinth Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 8 Thapakorn L. 3/7/2023 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ • "An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-19, Chapter 17, Section 17.10.5.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisfy the provisions of Section 17.10.5.3 (b), Section 17.10.5.3 (c), or Section 17.10.5.3 (d). The connection design (shear) shall satisfy the provisions of Section 17.10.6.3 (a), Section 17.10.6.3 (b), or Section 17.10.6.3 (c)." • Section 17.10.5.3 (b) / Section 17.10.6.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.10.5.3 (c) / Section 17.10.6.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non-yielding attachment. Section 17.10.5.3 (d) / Section 17.10.6.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased by w0. • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-19, Section 26.7. Fastening meets the design criteria! www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 9 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 350kW BTC Dispenser Plinth Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 9 Thapakorn L. 3/7/2023 Coordinates Anchor [in.] Anchor x y c-x c+x c-y c+y 1 -7.500 5.087 6.000 21.000 16.174 6.000 2 -7.500 0.000 6.000 21.000 11.087 11.087 3 -7.500 -5.087 6.000 21.000 6.000 16.174 Anchor x y c-x c+x c-y c+y 4 7.500 5.087 21.000 6.000 16.174 6.000 5 7.500 -0.000 21.000 6.000 11.087 11.087 6 7.500 -5.087 21.000 6.000 6.000 16.174 7 Installation data Anchor type and diameter: Kwik Bolt TZ2 - SS 304 1/2 (3 1/4 ) hnom3 Profile: no profile Item number: 2210261 KB-TZ2 1/2x4 1/2 SS304 Hole diameter in the fixture: df = 0.562 in. Maximum installation torque: 481 in.lb Plate thickness (input): 0.250 in. Hole diameter in the base material: 0.500 in. Recommended plate thickness: not calculated Hole depth in the base material: 4.250 in. Drilling method: Hammer drilled Minimum thickness of the base material: 5.500 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Hilti KB-TZ2 stud anchor with 3.75 in embedment, 1/2 (3 1/4 ) hnom3, Stainless steel, installation per ESR-4266 7.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Manual blow-out pump • Torque controlled cordless impact tool • Torque wrench • Hammer 1 2 3 4 5 6 x y 8.750 8.750 1.250 15.000 1.250 1. 5 0 0 -0 . 0 0 0 5. 0 8 7 -0 . 0 0 0 5. 0 8 7 -0 . 0 0 0 1. 5 0 1 6. 5 8 7 6. 5 8 7 Electrify America, LLC. / Generic FOUNDATION DESIGN Design Loads for Foundation: Dynamic :NO Vertical Equipment Load:1.0D =551 lbs Wind Load Govern - (D + 0.6W) Lateral Wind Load:0.6W =308 lbs Seismic Load Govern - (D + 0.7E) Lateral Seismic Load:0.7E =231 lbs Governing Lateral Load 308 lbs Wind Control March 3, 2023 Generic Calculation Electrify America, LLC. / Generic Generic Calculation DESIGN OF FOUNDATION 1.25 ft Soil Properties (IBC Table 1806.2) 1.00ft Soil Density =115 pcf Fs Pd Allowable Bearing Capacity =1.50 ksf Grade Friction Coefficient =0.35 Equipment Center to Edge Distance: 1.00 ft Foundation Center:1.25 ft Equipment Eccentricity:0.25 ft a. SOIL BEARING PRESSURE CHECK (1.0D + 0.6W) Soil Depth to Foundation:0.00 ft Mat Width:2.50 ft Mat Length:3.50 ft Mat Depth:3.00 ft Equipment Weight (Empty):0.55 kips Equipment Weight (Fully Loaded):0.55 kips Soil Weight Above Foundation: 0.00 kips Foundation Weight:3.94 kips Equipment Lateral Force:0.31 kips Equipment COM Height:7.50 ft Total Weight, P: 1.0DL =4.49 kips 0.6DL =2.69 kips Mat Area, A:8.75 sf P / A:0.51 ksf Moment by Equipment Eccentricity:0.14 kip-ft Total Moment, M:2.45 kip-ft Section Modulus of Mat, S:3.65 ft3 M / S:0.672 ksf P / A + M / S, qmax:1.185 ksf P / A - M / S, qmin:-0.159 ksf qmax, past kern limit:1.214 ksf Ratio of Max Bearing to Allowable Bearing:80.9%OK March 3, 2023 Wind Control Electrify America, LLC. / Generic Generic Calculation DESIGN OF FOUNDATION (cont) b. OVERTURNING STABILITY CHECK (0.6D + 0.6W)Note; Use empty weight Overturning Moment, OM =2.45 kip-ft Resisting Moment, RM =3.28 kip-ft Ratio of Overturning against Resisting Moment =74.6%OK c. SLIDING STABILITY CHECK (0.6D + 0.6W)Note; Use empty weight Sliding, V =0.31 kip Resisting Force, R =0.94 kip Ratio of Sliding against Resisting Force =32.7%OK d. STRENGTH DESIGN OF MAT Design parameters, As =0.41 in2 / ft (bottom rebar area per foot width of slab) b = 12.00 in (1 ft strip width of slab) d = 33.00 in (effective depth of slab) fc' =3.00 ksi (concrete compressive strength) fy =60.00 ksi (rebar yield strength) fv =0.75 (reduction factor for shear) fb =0.90 (reduction factor for bending) l =1.00 (modification factor) Section Layer of Rebar:2 #5 @ 9 33.0 12.00 Bending Check of Mat qmax =1.21 ksf (from soil bearing calculation) qu =1.82 ksf (average load factor =1.50) wuf =0.41 klf wus =1.82 klf wuf 0.41klf wuf 1.82klf wus Ru 1.50 ft March 3, 2023 3.0 36.0 Electrify America, LLC. / Generic Generic Calculation d. STRENGTH DESIGN OF MAT (cont.) Vu =2.12 kip/ft Mu =1.59 kip-ft/ft a =As fy / (0.85 f'c b) = 0.80 in fMn =fb As fy (d - a / 2) / 12 = 60.01 kip-ft / ft >Mu =1.59 kip-ft/ft OK SR =2.7% One - Way Shear (Wide Beam Shear) Check of Mat Size Effect Modification Factor, ls = √ [2 / (1 + d / 10)] ≤ 1 Section 22.5.5.1.3, Eqn (22.5.1.3) Note: ls =1.00 Concrete Section Gross Area,Ag = b*t =432.0 in2 / ft Reinforcement Ratio, rw = As,provided / b*d =0.0021 Shear Reinforcement Area,Av =0.00 in2 / ft Min. Shear Reinforcement Area Av,min =0.010 in2 / ft Table 9.6.3.4 Factored Axial Force,Nu =0.0 lbs / ft Note #1 of Table 22.5.5.1 Nu / (6Ag) =0.00 psi f'c,max =10000 psi Section 22.5.3.1 When Nu ≠ 0, Nu / (6Ag) ≤ 0.05f'c =150.0 psi Section 22.5.5.1.2 Use [Nu / (6Ag)] =0.0 psi Nominal Shear Capacity, fVc = f [2 λ √f'c + Nu / (6Ag)]* bw*d Table 22.5.5.1, Eqn (a) fVc = f [8 λ (ρw)1/3 √f'c + Nu/(6Ag)]*bw*d Table 22.5.5.1, Eqn (b) fVc = f [8 λs λ (ρw)1/3 √f'c + Nu/(6Ag)]*bw*d Table 22.5.5.1, Eqn (c) Governs Nominal Shear Capacity,fVc =16.57 kip / ft (Controls) Max. Limit of Shear Capacity,fVc (max) = f (5 λ √f'c *b*d) =81.34 kip / ft Section 22.5.5.1.1 fVc =16.57 kip / ft >Vu =2.12 kip / ft OK SR =12.8% March 3, 2023 1. When Av ≥ Av,min, Table 22.5.5.1, (without the size effect modification factor λs) is applicable for walls, elevated slabs and footing slabs. 2. When Av ≥ Av,min, smaller value of Eqn (a) and (b) is used. 3. When Av < Av,min, Table 22.5.5.1, Eqn (c) (with the size effect modification factor λs) is applicable for walls and elevated slabs and is neglected for footing slabs per Section 13.2.6.2. 4. When d < 10", λs = 1.0 When Av ≥ Av,min,Smaller of When Av < Av,min, Electrify America, LLC. / Generic Generic Calculation Temperature and Shrinkage Reinforcement Mat Ast =0.0018 Ag = 0.0018 x 3.00 x 12 x 12 0.78 in2 Ast / 2 = 0.39 Use #5 @ 9 Mat As,prov =0.31 x 1.33 x 2 = 0.82 in2 > 0.39 in2 OK Foundation Dimension: 3.50'L x 2.50'W x 3.00'D Foundation Reinforcement: #5 @ 9" O.C. EACH WAY TOP AND BOTTOM March 3, 2023 Electrify America, LLC. / CA200050 - Arcadia March 24, 2023 Generic Calculation Structural Design of Proposed 360kW BTC Power Unit Anchorage Electrify America, LLC. / Generic Generic Calculation SEISMIC LOAD CALCULATION The equipment is considered a Non-Structural Component per section 13.3 of ASCE 7-16. Fp = 0.4 ap SDS Wp (1 + 2 z/h) / (Rp/Ip)eq. 13.3-1 = 0.4 x 1.00 x 2.00 (1 + 2 x 0.00) / (2.50 / 1.00) Fp =0.32 Wp Fp = 1.6 SDS Ip Wp eq. 13.3-2 = 1.6 x 2.00 x 1.00 x Wp Fp =3.20 Wp (maximum) Fp = 0.30 SDS Ip Wp eq. 13.3.3 = 0.30 x 2.00 x 1.00 x Wp Fp =0.60 Wp (minimum)(Control) SDS =2.000 g design spectral response at short period (0.2 seconds) (see attached ASCE 7 Hazard Report) SDC = E seismic design Category Ip =1.00 component importance factor per Section 13.1.3 Rp =2.50 component response modification factor per table 13.5-1/13.6-1 ap =1.00 component amplification factor per table 13.5-1/13.6-1 z/h = 0.00 on ground Total Seismic Shear ; h = 8.25 ft (equipment height from ground) w = 2.50 ft (equipment width) l = 3.06 ft (equipment length) Wfull =1655 lbs Wempty =1655 lbs f Wfull =0.60 x 1,655 lbs = 993.0 lbs f Wempty =0.60 x 1,655 lbs = 993.0 lbs Eseis.H = Fp = March 2, 2023 h w I Electrify America, LLC. / Generic WIND LOAD CALCULATION ASCE Section # a. Velocity Pressure, qz Fig. 26-5 qz =0.00256 Kz Kzt Ke Kd V2 Basic Wind Speed, V = 115 mph Eq. 26.10-1 = 0.00256 x 0.85 x 1.00 x 1.00 x 0.85 x 115.00^2 qz = 24.43 psf b. Velocity pressure coefficient, Kz Sec. 26.10.1 Kz =2.01 (z/zg)2/a Exposure Category = C Tab. 26.10-1 = 2.01 (15 / 900^(2/9.5) Kz = 0.85 Height above Ground Level, z = 15 ft a =9.50 zg =900.00 ft Tab. 26.11-1 c. Topographic Factor, Kzt Sec. 26.8 m =0.00 H = 15 ft g =0.00 Hill Shape K1 =0.00 Crest Type K2 =(1 - x / m Lh)Distance Upwind of crest, Lh =0 ft = [1 - 15 / (0.0 x 0)] K2 =0.00 Distance Upwind to Bldg Site, x = 0 ft Fig. 26.8-1 K3 =e (g z / Lh)Kzt =[ 1 + K1 K2 K3 ]2 Eq. 26.8-1 = e^-(0.0 x 15 / 0)= [1 + 0.00 x 0.00 x 0.00]^2 K3 =0.00 Kzt =1.00 d. Ground Elevation Factor, Ke Ke =1.00 Sec. 26.9 e. Wind Directionality Factor, Kd Tab. 26.6-1 Kd =0.85 f. Risk Category II Tab. 1.5-1 g. Gust Effect Factor, G G = 0.85 Sec. 26.11 h. Structure Type / Force Coefficient Cf = 1.65 Min. Fig. 29.3-1 i. Design Wind Pressure,F = 24.43 x 0.85 x 1.65 = 34.26 psf (OK) Min. Req'd : 16 psf j. Total Wind Load On Equipment, Aopening =0.00 s.f. Projected Wind Area on Equipment Af =3.06 x 8.25 - 0 =25.25 s.f. Fwind =34.26 psf x 25.25 s.f. =864.9 lbs March 2, 2023 (8) Solid Sign (1) Solid Freestanding Signs / Walls Flat Terrain Downwind Generic Calculation Electrify America, LLC. / Generic ANCHORAGE DESIGN Input Design Loads: Weight of Equipment:WEmpty =1655 lbs WFull =1655 lbs Wind Load Govern - (0.9D - W) Vertical Load on Equipment:0.9D =1490 lbs Lateral Wind Load on Equipment:W =865 lbs Moment at Base:Mu = W (0.55h) =865 lbs x (0.55 x 8.25 ft x 12 in/ft) =47099 lbs-in Note: If SDC = C or greater, seismic load cases should be included in anchor analysis Seismic Load Govern - {(0.9 - 0.2SDS)D - E} Case 1 - Empty Vertical Load on Equipment:(0.9 - 0.2SDS)D =828 lbs, Empty Seismic Overstrength Factor:W =2.00 Lateral Seismic Load on Equipment with overstrength factor :Eseis.H =1986 lbs, Empty Moment at Base:Mu = E (0.67h) =1,986 lbs x (0.67 x 8.25 ft x 12 in/ft) =131731 lbs-in, Empty Case 2 - Fully loaded Vertical Load on Equipment:(0.9 - 0.2SDS)D =828 lbs, Fully Loaded Lateral Seismic Load on Equipment with overstrength factor :Eseis.H =1986 lbs, Fully Loaded Moment at Base:Mu = E (0.67h) =1,986 lbs x (0.67 x 8.25 ft x 12 in/ft) =131731 lbs-in, Fully Loaded March 2, 2023 Generic Calculation www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 360kW BTC Power Unit Platform Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 1 Thapakorn L. 2/3/2023 Specifier's comments: Wind and Seismic Case - 360kW BTC Power Unit Platform Anchorage 1 Input data Anchor type and diameter: HIT-RE 500 V3 + HAS-R 304/316 SS 1/2 Item number: 2045003 HAS-R 316 SS 1/2"x6 1/2" (element) / 2123401 HIT-RE 500 V3 (adhesive) Effective embedment depth: hef,act = 4.000 in. (hef,limit = - in.) Material: ASTM F 593 Evaluation Service Report: ESR-3814 Issued I Valid: 1/3/2021 | 1/1/2023 Proof: Design Method ACI 318-19 / Chem Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.250 in. Anchor plateR : lx x ly x t = 33.000 in. x 34.000 in. x 0.250 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 3000, fc' = 3,000 psi; h = 8.000 in., Temp. short/long: 32/32 °F Installation: hammer drilled hole, Installation condition: Water saturated Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) Shear load: yes (17.10.6.3 (c)) Application also possible with HVU2 + HAS-R 304/316 SS 1/2 under the selected boundary conditions. More information in section Alternative fastening data of this report. R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [lb, in.lb] www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 360kW BTC Power Unit Platform Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 2 Thapakorn L. 2/3/2023 1.1 Load combination and design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Wind Case N = -1,490; Vx = 0; Vy = 865; Mx = -47,099; My = 0; Mz = 0; Nsus = 0; Mx,sus = 0; My,sus = 0; no 15 2 Seismic Case N = -828; Vx = 0; Vy = 1,986; Mx = -131,731; My = 0; Mz = 0; Nsus = 0; Mx,sus = 0; My,sus = 0; yes 66 Tension Compression 1 2 3 4 x y2 Load case/Resulting anchor forces Controlling load case: 2 Seismic Case Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 1,887 496 0 496 2 1,887 496 0 496 3 0 496 0 496 4 0 496 0 496 max. concrete compressive strain: 0.03 [‰] max. concrete compressive stress: 136 [psi] resulting tension force in (x/y)=(-0.000/-15.000): 3,775 [lb] resulting compression force in (x/y)=(-0.000/16.318): 4,603 [lb] Anchor forces are calculated based on the assumption of a rigid anchor plate. 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*1,887 9,223 21 OK Bond Strength**3,775 5,783 66 OK Sustained Tension Load Bond Strength*N/A N/A N/A N/A Concrete Breakout Failure**3,775 7,263 52 OK * highest loaded anchor **anchor group (anchors in tension) www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 360kW BTC Power Unit Platform Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 3 Thapakorn L. 2/3/2023 3.1 Steel Strength Nsa = ESR value refer to ICC-ES ESR-3814 f Nsa ³ Nua ACI 318-19 Table 17.5.2 Variables Ase,N [in.2]futa [psi] 0.14 100,000 Calculations Nsa [lb] 14,190 Results Nsa [lb]f steel f nonductile f Nsa [lb]Nua [lb] 14,190 0.650 1.000 9,223 1,887 www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 360kW BTC Power Unit Platform Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 4 Thapakorn L. 2/3/2023 3.2 Bond Strength Nag = (ANa ANa0)y ec1,Na y ec2,Na y ed,Na y cp,Na Nba ACI 318-19 Eq. (17.6.5.1b) f Nag ³ Nua ACI 318-19 Table 17.5.2 ANa see ACI 318-19, Section 17.6.5.1, Fig. R 17.6.5.1(b) ANa0 = (2 cNa)2 ACI 318-19 Eq. (17.6.5.1.2a) cNa = 10 da √t uncr 1100 ACI 318-19 Eq. (17.6.5.1.2b) y ec,Na = (1 1 + e' NcNa )£ 1.0 ACI 318-19 Eq. (17.6.5.3.1) y ed,Na = 0.7 + 0.3 (ca,mincNa)£ 1.0 ACI 318-19 Eq. (17.6.5.4.1b) y cp,Na = MAX(ca,min cac , cNa cac)£ 1.0 ACI 318-19 Eq. (17.6.5.5.1b) Nba = l a · t k,c · aN,seis · p · da · hef ACI 318-19 Eq. (17.6.5.2.1) Variables t k,c,uncr [psi]da [in.]hef [in.]ca,min [in.]aoverhead t k,c [psi] 2,407 0.500 4.000 6.000 1.000 1,305 ec1,N [in.]ec2,N [in.]cac [in.]l a aN,seis 0.000 0.000 7.874 1.000 0.930 Calculations cNa [in.]ANa [in.2]ANa0 [in.2]y ed,Na 7.363 357.15 216.87 0.944 y ec1,Na y ec2,Na y cp,Na Nba [lb] 1.000 1.000 1.000 7,627 Results Nag [lb]f bond f seismic f nonductile f Nag [lb]Nua [lb] 11,863 0.650 0.750 1.000 5,783 3,775 www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 360kW BTC Power Unit Platform Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 5 Thapakorn L. 2/3/2023 3.3 Concrete Breakout Failure Ncbg = (ANc ANc0)y ec,N y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1b) f Ncbg ³ Nua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ec,N = (1 1 + 2 e' N 3 hef )£ 1.0 ACI 318-19 Eq. (17.6.2.3.1) y ed,N = 0.7 + 0.3 (ca,min1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,mincac , 1.5hefcac)£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables hef [in.]ec1,N [in.]ec2,N [in.]ca,min [in.]y c,N 4.000 0.000 0.000 6.000 1.000 cac [in.]kc l a f' c [psi] 7.874 17 1.000 3,000 Calculations ANc [in.2]ANc0 [in.2]y ec1,N y ec2,N y ed,N y cp,N Nb [lb] 288.00 144.00 1.000 1.000 1.000 1.000 7,449 Results Ncbg [lb]f concrete f seismic f nonductile f Ncbg [lb]Nua [lb] 14,898 0.650 0.750 1.000 7,263 3,775 www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 360kW BTC Power Unit Platform Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 6 Thapakorn L. 2/3/2023 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*496 4,087 13 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength (Bond Strength controls)**1,986 33,215 6 OK Concrete edge failure in direction y+**1,986 5,979 34 OK * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa,eq = ESR value refer to ICC-ES ESR-3814 f Vsteel ³ Vua ACI 318-19 Table 17.5.2 Variables Ase,V [in.2]futa [psi]aV,seis 0.14 100,000 0.800 Calculations Vsa,eq [lb] 6,812 Results Vsa,eq [lb]f steel f nonductile f Vsa,eq [lb]Vua [lb] 6,812 0.600 1.000 4,087 496 www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 7 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 360kW BTC Power Unit Platform Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 7 Thapakorn L. 2/3/2023 4.2 Pryout Strength (Bond Strength controls) Vcpg =kcp[(ANa ANa0)y ec1,Na y ec2,Na y ed,Na y cp,Na Nba ] ACI 318-19 Eq. (17.7.3.1b) f Vcpg ³ Vua ACI 318-19 Table 17.5.2 ANa see ACI 318-19, Section 17.6.5.1, Fig. R 17.6.5.1(b) ANa0 = (2 cNa)2 ACI 318-19 Eq. (17.6.5.1.2a) cNa = 10 da √t uncr 1100 ACI 318-19 Eq. (17.6.5.1.2b) y ec,Na = (1 1 + e' NcNa )£ 1.0 ACI 318-19 Eq. (17.6.5.3.1) y ed,Na = 0.7 + 0.3 (ca,mincNa)£ 1.0 ACI 318-19 Eq. (17.6.5.4.1b) y cp,Na = MAX(ca,min cac , cNa cac)£ 1.0 ACI 318-19 Eq. (17.6.5.5.1b) Nba = l a · t k,c · aN,seis · p · da · hef ACI 318-19 Eq. (17.6.5.2.1) Variables kcp aoverhead t k,c,uncr [psi]da [in.]hef [in.]ca,min [in.]t k,c [psi] 2 1.000 2,407 0.500 4.000 6.000 1,305 ec1,N [in.]ec2,N [in.]cac [in.]l a aN,seis 0.000 0.000 7.874 1.000 0.930 Calculations cNa [in.]ANa [in.2]ANa0 [in.2]y ed,Na 7.363 714.31 216.87 0.944 y ec1,Na y ec2,Na y cp,Na Nba [lb] 1.000 1.000 1.000 7,627 Results Vcpg [lb]f concrete f seismic f nonductile f Vcpg [lb]Vua [lb] 47,450 0.700 1.000 1.000 33,215 1,986 www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 8 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 360kW BTC Power Unit Platform Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 8 Thapakorn L. 2/3/2023 4.3 Concrete edge failure in direction y+ Vcbg = (AVc AVc0)y ec,V y ed,V y c,V y h,V y parallel,V Vb ACI 318-19 Eq. (17.7.2.1b) f Vcbg ³ Vua ACI 318-19 Table 17.5.2 AVc see ACI 318-19, Section 17.7.2.1, Fig. R 17.7.2.1(b) AVc0 = 4.5 c2 a1 ACI 318-19 Eq. (17.7.2.1.3) y ec,V = (1 1 + e' v 1.5ca1 )£ 1.0 ACI 318-19 Eq. (17.7.2.3.1) y ed,V = 0.7 + 0.3(ca21.5ca1)£ 1.0 ACI 318-19 Eq. (17.7.2.4.1b) y h,V = √1.5ca1ha ³ 1.0 ACI 318-19 Eq. (17.7.2.6.1) Vb = (7 (leda)0.2 √da)l a √f' c c1.5 a1 ACI 318-19 Eq. (17.7.2.2.1a) Variables ca1 [in.]ca2 [in.]ecV [in.]y c,V ha [in.] 6.000 6.000 0.000 1.000 8.000 le [in.]l a da [in.]f' c [psi]y parallel,V 4.000 1.000 0.500 3,000 1.000 Calculations AVc [in.2]AVc0 [in.2]y ec,V y ed,V y h,V Vb [lb] 240.00 162.00 1.000 0.900 1.061 6,039 Results Vcbg [lb]f concrete f seismic f nonductile f Vcbg [lb]Vua [lb] 8,541 0.700 1.000 1.000 5,979 1,986 5 Combined tension and shear loads, per ACI 318-19 section 17.8 bN bV z Utilization bN,V [%]Status 0.653 0.332 5/3 66 OK bNV = bz N + bz V <= 1 www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 9 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 360kW BTC Power Unit Platform Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 9 Thapakorn L. 2/3/2023 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Design Strengths of adhesive anchor systems are influenced by the cleaning method. Refer to the INSTRUCTIONS FOR USE given in the Evaluation Service Report for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ • "An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-19, Chapter 17, Section 17.10.5.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisfy the provisions of Section 17.10.5.3 (b), Section 17.10.5.3 (c), or Section 17.10.5.3 (d). The connection design (shear) shall satisfy the provisions of Section 17.10.6.3 (a), Section 17.10.6.3 (b), or Section 17.10.6.3 (c)." • Section 17.10.5.3 (b) / Section 17.10.6.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.10.5.3 (c) / Section 17.10.6.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non-yielding attachment. Section 17.10.5.3 (d) / Section 17.10.6.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased by w0. • Installation of Hilti adhesive anchor systems shall be performed by personnel trained to install Hilti adhesive anchors. Reference ACI 318-19, Section 26.7. Fastening meets the design criteria! www.hilti.com Hilti PROFIS Engineering 3.0.83 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 10 Company: Address: Phone I Fax: Design: Fastening point: Black & Veatch Corp. | 360kW BTC Power Unit Platform Anchorage ELECTRIFY AMERICA Page: Specifier: E-Mail: Date: 10 Thapakorn L. 2/3/2023 Coordinates Anchor [in.] Anchor x y c-x c+x c-y c+y 1 -15.500 -15.000 6.000 37.000 6.000 36.000 2 15.500 -15.000 37.000 6.000 6.000 36.000 3 -15.500 15.000 6.000 37.000 36.000 6.000 4 15.500 15.000 37.000 6.000 36.000 6.000 7 Installation data Anchor type and diameter: HIT-RE 500 V3 + HAS-R 304/316 SS 1/2 Profile: no profile Item number: 2045003 HAS-R 316 SS 1/2"x6 1/2" (element) / 2123401 HIT-RE 500 V3 (adhesive) Hole diameter in the fixture: df = 0.562 in. Maximum installation torque: 360 in.lb Plate thickness (input): 0.250 in. Hole diameter in the base material: 0.562 in. Recommended plate thickness: not calculated Hole depth in the base material: 4.000 in. Drilling method: Hammer drilled Minimum thickness of the base material: 5.250 in. Cleaning: Compressed air cleaning of the drilled hole according to instructions for use is required 1/2 Hilti HAS Stainless steel threaded rod with Hilti HIT-RE 500 V3 7.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Compressed air with required accessories to blow from the bottom of the hole • Proper diameter wire brush • Dispenser including cassette and mixer • Torque wrench 1 2 3 4 x y 16.500 16.500 1.000 31.000 1.000 2. 0 0 0 30 . 0 0 0 2. 0 0 0 17 . 0 0 0 17 . 0 0 0 Electrify America, LLC. / CA200050 - Arcadia Generic Calculation March 24, 2023 APPENDIX B Attachments ASCE 7 Hazards Report Address: No Address at This Location Standard:ASCE/SEI 7-16 Latitude:34.107177 Risk Category:II Longitude:-118.024387 Soil Class:D - Default (see Section 11.4.3) Elevation:343.24777254888903 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Thu Mar 23 2023 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 1 of 3https://asce7hazardtool.online/Thu Mar 23 2023 SS : 1.853 S1 : 0.616 Fa : 1.2 Fv : N/A SMS : 2.224 SM1 : N/A SDS : 1.483 SD1 : N/A TL : 8 PGA : 0.795 PGA M : 0.954 FPGA : 1.2 Ie : 1 Cv : 1.471 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Thu Mar 23 2023 Page 2 of 3https://asce7hazardtool.online/Thu Mar 23 2023 Ice Results: Data Source: Date Accessed: Ice Thickness: 0 in. Concurrent Temperature: 25 F Gust Speed 30 mph Standard ASCE/SEI 7-16, Figs. 10-2 through 10-8 Thu Mar 23 2023 Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds, for a 500-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain. Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. Page 3 of 3https://asce7hazardtool.online/Thu Mar 23 2023 This document is a Property of BTCPower Inc. and shall not be copied, reproduced, or used as the basis for sale or manufacture of apparatus without written permission. 23-Sep-22 Rev D 360kW High Power DC Charger INSTALLATION AND USER’S MANUAL Page 14 of 89 SYSTEM SPECIFICATION 4.2. DCFC Dispenser High Power Dispenser Specification SKU: HPCD6-500-05-005 PARAMETER DISPENSER 500A Rated AC Input Auxiliary Input Voltage 480 VAC, Split Phase, +/-10% (L1, L2, Ground) Auxiliary Input Current 6A @ 480 VAC Input Frequency Range 60 Hz ± 10 % DC Input Input Voltage Range 200 - 950 V Input Current Range 5 – 500 A DC Output CCS Configuration Maximum DC Output Current CCS, continuous 500 A Environment Conditions Operating Temperature Range -30°C to +50°C Operating Altitude 2,000 m Humidity 5-95% non-condensing Mechanical Characteristics Enclosure IK Rating IK 10 Enclosure IP Rating IP 54 (NEMA 3R) Dimensions Footer: 22” (W) x 16.8” (D) x 96.8” (H) Overall: 31.5” (W) x 18.7” (D) x 96.8” (H) Weight 551 lbs *Specifications are subject to change, without prior notice. This document is a Property of BTCPower Inc. and shall not be copied, reproduced, or used as the basis for sale or manufacture of apparatus without written permission. 23-Sep-22 Rev D 360kW High Power DC Charger INSTALLATION AND USER’S MANUAL Page 28 of 89 INSTALLATION Dispenser Installation Drawing 7.2.2. Tower and Dispenser Mounting Both the Tower and Dispenser must be fixed on a concrete pad. The Tower requires four (4) ½" x 4" (P/N RHPA-3830) concrete expansion bolts, and the Dispenser requires six (6) ½" x 4" (P/N RHPA- 3830) concrete expansion bolts or as determined appropriate by the structural engineer in- charge. Make sure to check local codes for compliance. This document is a Property of BTCPower Inc. and shall not be copied, reproduced, or used as the basis for sale or manufacture of apparatus without written permission. 23-Sep-22 Rev D 360kW High Power DC Charger INSTALLATION AND USER’S MANUAL Page 30 of 89 INSTALLATION Dispenser Footer Drawing The illustration below shows the drilling layout for the Dispenser. Six (6) points are needed to fix the unit on the concrete pad. The conduit entry to the unit is also shown. Base foundation template for alignment and hole location is available in .step or .dxf files upon request. NOTE The bottom of the dispenser needs to be sealed to the ground. 18.50 14.175 10.00 5.00 1.18 THRU X4 .53 .78 THRU X6 6.34 6.34 7.00 1.42 1.40 2.40 7.60 1.18 DRILL ACCESS HOLE X4 PANEL PLUGSX4 6.00 17.50 .060 8.72 8.72 18.50 13.175 6.00 14.18 .25 2.00 .125 2.00 2.00 R.13 .53THRU X6 .53 THRU x6 2 2 1 .25" FILLET WELD .25" FILLET STITCH WELD 4 ITEM NO.PART NUMBER DESCRIPTION QTY. 1 LM-BV-Footer-003 1 2 LM-BV-Footer-002 2 3 93560A280 Steel Hex Weld Nut 6 4 9750K43 Panel Plugs 4 THE INFORMATION CONTAINED HEREIN IS PROPRIETARY AND THE SOLE PROPERTY OF LATEST CONCEPTS INC. ANY REPRODUCTION OR USE, IN FULL OR IN PART, WITHOUT THE WRITTEN PERMISSION OF LATEST CONCEPTS INC IS PROHIBITIED . LATEST METALWORKS.PN: LM-BV-DISP-PLATFORM-REV 03 Title Description This document is a Property of BTCPower Inc. and shall not be copied, reproduced, or used as the basis for sale or manufacture of apparatus without written permission. 09-Nov-21 Initial Release 360kW High Power DC Charger INSTALLATION AND USER’S MANUAL Page 11 of 67 SYSTEM SPECIFICATION 4. System Specification 4.1. DCFC Power Unit AC to DC Power Converter Specification SKU: HPCT2-360-480-2 PARAMETER HPCT2-360-480-2 AC Input Input Voltage Range 480 VAC, 3 Phase, +10% / -15% Input Frequency Range 47 – 63 Hz Input Current @ 480 VAC 480 A Panel Breaker 600A Power Factor > 0.99 full load Total Harmonic Distortion < 5% Efficiency > 94% SCCR 65kA DC Output Output Voltage Range 200 – 950 VDC Number Of Outputs 2 Max Output Current (per output) 500A Maximum Output Power 360 kW Minimum Output Current 5A Output Ripple Current < 15 Ap–p (Bandwidth 1 kHz) Protection Over Temperature Self–protected and latched Output Over Voltage Output Shutdown and Latched Output Overload Output Shutdown and Latched CAN Communication Loss 1 sec Shutdown Upon Loss of Connection Safety Standards Isolation UL 2202 EMC Standards Harmonics IEC 61000-3-12 Immunity UL 2231-2 Environment Conditions Operating Temperature Range -30°C to +50°C ** Operating Altitude 2,000 meters. Humidity 95% Non-Condensing Mechanical Characteristics Dimensions 29.9” W x 40.3” D x 90.7” H Weight 1655 lbs Enclosure IK Rating IK 10 Enclosure IP Rating IP 54 (NEMA 3R) *Specifications are subject to change, without prior notice. This document is a Property of BTCPower Inc. and shall not be copied, reproduced, or used as the basis for sale or manufacture of apparatus without written permission. 09-Nov-21 Initial Release 360kW High Power DC Charger INSTALLATION AND USER’S MANUAL Page 25 of 67 INSTALLATION 7.2. Mounting Procedures 7.2.1. Clearance Around the Unit Clearance surrounding the unit must be considered for proper ventilation and service accessibility. Refer to the installation drawings as illustrated below. Power Unit / Tower Installation Drawing This document is a Property of BTCPower Inc. and shall not be copied, reproduced, or used as the basis for sale or manufacture of apparatus without written permission. 09-Nov-21 Initial Release 360kW High Power DC Charger INSTALLATION AND USER’S MANUAL Page 27 of 67 INSTALLATION Power Unit / Tower Footer Drawing The illustration below shows the drilling layout for the Power Unit / Tower. Only four (4) points are needed to fix the unit on the concrete pad. The conduit entry to the unit is also shown. Base foundation template for alignment and hole location is available in .step or .dxf files upon request. NOTE The bottom of the tower needs to be sealed to the ground. Electrify America, LLC. / CA200050 - Arcadia Generic Calculation March 24, 2023 APPENDIX C Structural Detail Sketches REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 0 03/29/23 ISSUED FOR CONSTRUCTION CA200050 ARCADIA ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 NMB KKP 406879 EQUIPMENT DETAILS D-1 DNO SCALE BANO SCALE ENO SCALE CNO SCALE FNO SCALE NO SCALE DISPENSER PLINTH 1.OPERABLE PARTS OF DISPENSER TO FRONT OF CURB SHALL BE 10" MAX. 2.OPERABLE PARTS OF DISPENSER SHALL NOT EXCEED 54" ABOVE PARKING SURFACE WHEN DISPENSER IS ON A CURB. 3.FRONT OF DISPENSER BASE PLATE TO LINE UP WITH FACE OF EXISTING DISPENSER SO ADA REACH RANGE IS MAINTAINED. THIS SHOULD BE AROUND 12". NOTES DISPENSER FOOTING DETAIL DISPENSER C.L. PLAN FRONT SIDE EXISTING 6" COMPACTED GRANULAR BACKFILL CAR SIDE EXISTING ASPHALT GRADE 98 . 2 4 " 48 " M A X CAR SIDE PROPOSED PLINTH EXISTING CONCRETE E - EXISTING FOOTING 3'-6" 2'- 6 " NO T E 3 3' - 0 " VI F EXISTING ASPHALT GRADE POWER UNIT PLATFORM 1.DIAMOND PLATE TO BE INSTALLED ON TOP OF W BEAMS WITH HOLES CUT FOR CONDUIT OPEN AREAS. 2.GALVANIZED SHEET METAL TO BE WELDED BETWEEN W BEAMS TO COVER OPENING. THIS MAY BE OMITTED WHERE A RACEWAY IS PROPOSED. 3.MINIMUM CONCRETE EDGE DISTANCE FOR PROPOSED ANCHORS SHALL BE 6". 4.W-BEAMS TO RUN UNDER ENTIRE LENGTH OF POWER UNITS. 5.ALLOWED TO USE EFFECTIVE EMBEDMENT OF 2" WHEN NOT NEAR POWER UNIT. SPACING MAY BE INCREASED TO 8' MAX WHEN NOT NEAR POWER UNIT. NOTES 1/2” DIA. HILTI HAS-R 304/316 SS ANCHOR WITH HILTI HIT-RE 500 V3 EPOXY & MINIMUM EFFECTIVE EMBEDMENT OF 4” OR ENGINEER APPROVED EQUAL. (ESR-3814) (TYP @ 2'-6" O.C.) (WITHIN 1' OF POWER UNIT) (NOTE 5) NOTE 2 HOT DIPPED GALVANIZED W6X12 (TYP) SECTION 1 1 - 1" SEE SITE PLAN 2" (TYP) 7/ 8 " (T Y P ) POWER UNIT ANCHORAGE (TYP) EXISTING FOOTING POWER UNIT FOOTER 2'-6" MAX NOTE 2 NOTE 4 DIAMOND PLATE AND GALVANIZED STEEL CONNECTION DETAIL W6x12 (TYP) NOTES: 1.1/4" DIAMOND PLATE SHALL HAVE A MINIMUM 36 KSI YIELD STRENGTH, HOT DIP GALVANIZED, AND IN ACCORDANCE TO ASTM A786. 2.EDGE OF DIAMOND PLATE SHALL BE FLUSH WITH EDGE OF PROPOSED W BEAM. 3.NON-SHRINK GROUT SHALL BE SET AS NEEDED AFTER W BEAMS ARE LEVELED TO ENSURE CONTINUOUS BEARING SURFACE ALONG CHANNEL LENGTH. NON-SHRINK GROUT SHALL ARCHIVE FULL COMPRESSIVE STRENGTH PER MANUFACTURER'S SPECIFICATION PRIOR TO INSTALLATION OF PROPOSED EQUIPMENT. 4.NO DIAMOND PLATE IS PROPOSED BELOW DISPENSERS. SEE SITE PLAN FOR DIAMOND PLATE AT POWER UNIT. CONTRACTOR TO FIELD SCAN FLOOR SLAB FOR REINFORCEMENT, ENSURE 1" MINIMUM GAP BETWEEN ALL ANCHORAGE AND EXISTING REINFORCEMENT. CUTTING AND DAMAGING EXISTING REBAR IS PROHIBITED 1" ADHERED CSPE BASE FLASHING (TYP) 1/4" DIA ASTM A307 HDG BOLT W/ NUT AND WASHER (@12" O.C.) EXISTING CONCRETE FOUNDATION 2' - 5 " E&F - TOP VIEW FRONT VIEWLEFT SIDE VIEW RIGHT SIDE VIEW WEIGHT = 1655 LBS 2'-6" 3'- 4 . 5 " 2'-9"4"2'-6"3'-1"4" 7' - 9 " 2" 2'- 8 " 2" 1'- 9 " 1'-0" 1'- 0 " 1'-8 1/2" POWER UNIT DETAIL PROPOSED PLATFORM EXISTING CONCRETE PAD F - 1.MINIMUM CONCRETE EDGE DISTANCE FOR PROPOSED ANCHORS SHALL BE 6". 2.EXISTING DISPENSER CONDUIT WINDOW. NOTES 18.5" 13 . 6 7 5 " 1/2" DIA. HILTI KWIK BOLT TZ2 SS 304/316 MECHANICAL ANCHOR WITH MINIMUM EFFECTIVE EMBEDMENT OF 3 1/4" OR ENGINEER APPROVED EQUAL. (ESR-4266)(TYP OF 6 PER PLINTH) HOT DIPPED GALVANIZED MANUFACTURED PLINTH (TYP) DISPENSER FOOTER NOTE 2 FRONT OF DISPENSER DISPENSER ANCHORAGE (TYP) EXISTING FOOTING DETAIL NOT USED B D-2 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 2003 EDMUND HALLEY DRIVE SUITE 200 RESTON, VIRGINIA 20191 0 03/29/23 ISSUED FOR CONSTRUCTION CA200050 ARCADIA ALBERTSONS 0561 298 E. LIVE OAK AVE. ARCADIA, CA 91006 NMB KKP 406879 EQUIPMENT DETAILS D-2 DNO SCALE ENO SCALE FNO SCALE B CNO SCALEANO SCALE DETAIL NOT USED NO SCALE DETAIL NOT USED DETAIL NOT USED POWER UNIT ANCHORAGE DETAIL INSTALLATION FOOTER 5/8" DIA ASTM A325 HDG BOLT W/ NUT AND WASHER, (TYP, TOTAL OF 4) OPEN AREA 1'-5"x1'-7" 1'-8" 2' - 5 " 3" 1' - 7 " 1'-5" 1" 5" 2'-5" 2'- 8 " 3" 1.CONTRACTOR TO FIELD VERIFY THE ANCHOR SPACING PER MANUFACTURER'S INSTALLATION MANUAL. NOTE 5/8" DIA. ASTM A325 HDG BOLT W/ NUT AND WASHER (TYP, TOTAL OF 6) DISPENSER ANCHORAGE DETAIL 12.68"4.405" 1. 4 " 7"8" 9.84" CONDUIT AREA 1.CONTRACTOR TO FIELD VERIFY THE ANCHOR SPACING PER MANUFACTURER'S INSTALLATION MANUAL. NOTE 6.34"6.34" DETAIL NOT USED