Loading...
HomeMy WebLinkAbout157-159 Genoa St A & B - 2022 -SITE ADDRESS 157 AND 159 GENOA STREET ARCADIA, CA 91007 LEGAL DESCRIPTION TRACT # 866 LOT 15 BLK 63 ASSESSOR'S PARCEL NUMBER 5779-009-015 SITE AREA 8,440 SF (PER LA COUNTRY ASSESSOR) ZONING R-3 HIGH DENSITY (AUTOMOBILE PARKING OVERLAY) OCCUPANCY R-3/U CONSTRUCTION TYPE V-B, SPRINKLERED PER NFPA 13D EXISTING USE 2 SINGLE-FAMILY RESIDENCES (746 SF +1,116 SF = 1,862 SF) PROPOSED USE 4 MULTI-FAMILY RESIDENCES (2 BUILDINGS) ALLOWED PROPOSED DENSITY MAXIMUM 5 UNITS 4 UNITS (1 UNIT PER 1,450 SF OF LOT AREA = 5.732) MAX.BUILDING HEIGHT 30'-0"29'-11" BUILDING SETBACK REQUIRED PROPOSED FRONT 25'-0"25'-0" SIDE 10'-0" 10'-0" REAR 10'-0"10'-0" OPEN SPACE REQUIRED PROPOSED PER UNIT 100 SF MIN.121, 207, 328, 328 SF AREA BREAKDOWN UNIT 1 UNIT 2 UNIT 3 UNIT 4 TOTAL LIVABLE AREA 1,335 SF 1,922 SF 1,922 SF 1,939 SF 7,118 SF GARAGE AREA 515 SF 463 SF 463 SF 463 SF 1,904 SF BASEMENT DRIVEWAY AREA:BLDG 1:2,328 SF BLDG 2:2,618 SF PARKING PROVIDED REQUIRED PROPOSED PER UNIT 8 SPACES (2 PER UNIT X 4 UNITS)8 SPACES (2 PER GARAGE) GUEST 2 SPACES 2 SPACES 10 SPACES 10 SPACES TOTAL BICYCLE PARKING PROVIDED REQUIRED PROPOSED 2 SPACES 2 SPACES A0.1 PROJECT DATA & COVER SHEET DRAWING INDEX NUMBER ARCHITECTURAL A0.1 A2.1 A2.2 A1.2 ENERGY CALCULATION A2.5 S1.0 A0.2 A0.4 S1.1 S1.2 S1.3 S1.4 S1.5 S1.6 S2.3 A0.6 A0.3 A0.5 S2.0 A2.3 A2.4 A2.6 A1.1 A2.7 M-0.1 C-1 C-2 C-3 VICINITY MAP PROJECT DIRECTORY CONTACT: VINCENT TSOI ARCHITECT PHONE: 626.799.8818 X 100 1414 FAIR OAKS AVENUE, SUITE 3 SOUTH PASADENA, CALIFORNIA 91030 SPACE LIGHT STRUCTURE DESIGN INC. FAX: 626.799.8823 CONTACT: HANK JONG CIVIL ENGINEER PHONE: 626.263.3588 11819 GOLDRING ROAD, UNIT A ARCADIA, CA 91006 EGL ASSOCIATES FAX: 626.263.3599 ENERGY CALCULATIONS CONTACT: HANK CHANG PHONE: 909.396.8168 556 N. DIAMOND BAR BLVD, SUITE 304 DIAMOND BAR, CALIFORNIA 91765 HYC CONSULTING ENGINEERS, INC. FAX: 909.396.8169 LANDSCAPE ARCHITECT EMAIL: JKDA2002@GMAIL.COM WALNUT, CA 91789 PHONE: 626.383.7758 SAIL DESIGN GROUP, INC. STRUCTURAL ENGINEER EMAIL: CALCIVIC@EARTHLINK.NET PHONE: 626.798.2828 2160 PARNELL WAY ALTADENA, CALIFORNIA 91001 CALCIVIC ENGINEERING, INC. FAX: 626.798.6644 7143 VISTA DEL ORO LA VERNE, CA 91750 YIJUN JIANG OWNER CONTACT: KEVIN CBC 2022 CALIFORNIA BUILDING CODE - TITLE 24, PART 2 CEC 2022 CALIFORNIA ELECTRICAL CODE - TITLE 24, PART 3 CMC 2022 CALIFORNIA MECHANICAL CODE - TITLE 24, PART 4 CPC 2022 CALIFORNIA PLUMBING CODE - TITLE 24, PART 5 2022 CALIFORNIA ENERGY CODE - TITLE 24, PART 6 CFC 2022 CALIFORNIA FIRE CODE CRC 2022 CALIFORNIA RESIDENTIAL CODE - TITLE 24, PART 2.5 CGC 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE - TITLE 24, PART 11 CITY OF ARCADIA MUNICIPAL ZONING CODES. PLAN CHECK & PERMIT NOTES STATE REQUIREMENTS ·AT TIME OF PERMIT ISSUANCE, CONTRACTOR SHALL SHOW THEIR VALID WORKERS' COMPENSATION INSURANCE CERTIFICATE. ·ALL WORK SHALL CONFORM TO ALL REQUIREMENTS OF STATE OF CALIFORNIA TITLE 24 REGARDLESS OF THE INFORMATION INDICATED ON THESE PLANS. IT IS THE RESPONSIBILITY OF THE INDIVIDUAL SUPERVISING THE CONSTRUCTION TO ENSURE THAT THE WORK IS DONE IN ACCORDANCE WITH CODE REQUIREMENTS PRIOR TO REQUESTING INSPECTION. ·EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR ANY OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTES ON SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTE. ·SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE STABILIZED SO AS TO INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC WAY. ACCIDENTAL DEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN OR OTHER MEANS. ·STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED MATERIALS MUST BE PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY THE FORCES OF WIND OR WATER. ·TRASH AND CONSTRUCTION RELATED SOLID WASTES MUST BE DEPOSITED INTO A COVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND DISPERSAL BY WIND. ·FUELS OILS, SOLVENTS AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE WITH THEIR LISTING AND ARE NOT TO CONTAMINATE THE SOIL AND SURFACE WATERS. ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED INTO THE DRAINAGE SYSTEM. · SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) SHALL BE NOTIFIED IN ACCORDANCE WITH CALIFORNIA STATE LAW PRIOR TO START OF ANY DEMOLITION, ADDITION, AND/OR REMODEL WORK. THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT OFFICE IS LOCATED AT 21865 COPLEY DRIVE IN DIAMOND BAR, PHONE NO. (909) 396-2000. BE ADVISED SCAQMD MAY REQUIRE A 10 DAY WAIT PERIOD PRIOR TO START OF WORK. BEST MANAGEMENT PRACTICES SCOPE OF WORK G E N O A 4 U N I T S GENERAL STRUCTURAL NOTES BASEMENT FOUNDATION PLAN BASEMENT FRAMING 1ST FLOOR FRAMING 2ND FLOOR AND ROOF FRAMING STRUCTURAL DETAILS STRUCTURAL DETAILS S2.4 STRUCTURAL DETAILS ·DEMOLISH (2) EXISTING 1-STORY HOUSES AND ATTACHED GARAGES. ·CONSTRUCT (2) NEW MULTI-FAMILY 2-STORY CONDOMINIUM BUILDINGS (R-3 OCCUPANCY - 7,118 SF) WITH BASEMENT UNIT GARAGES (U OCCUPANCY - 1,904 SF). ·CONSTRUCT BASEMENT GARAGE AND DRIVEWAYS (S-2 OCCUPANCY - 3,042 SF)PHONE: 626.524.0592 DEFERRED SUBMITTALS SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING: 1.FIRE SPRINKLER 2.MECHANICAL 3.ELECTRICAL 4.PLUMBING 5.CONCRETE MASONRY BLOCK WALLS 6.DEMOLITION (MUST BE OBTAINED PRIOR TO OR AT THE SAME TIME AS BLDG. PERMIT ISSUANCE) 7.PUBLIC WORKS (CONSTRUCTION WITHIN PUBLIC RIGHT-OF-WAY) PROJECT DATA NUMBER GRADING / DRAINAGE PLAN (PARCEL MAP NO. 82441)SHEET INDEX / PROJECT DATA A4.1 BUILDING 1 EXTERIOR ELEVATIONS UNIT TYPE A FLOOR PLANS OVERALL BASEMENT PLAN A4.2 BUILDING 2 EXTERIOR ELEVATIONS A3.2 BUILDING 2 ROOF PLAN UNIT TYPE B2 FLOOR PLANS A6.2 SITE STAIR SECTIONS PLANNING COMMISSION CONDITIONS OF APPROVAL 2022 CALGREEN REQUIREMENTS 2022 CALGREEN REQUIREMENTS (CONT.) GENERAL NOTES PLANNING COMMISSION CONDITIONS OF APPROVAL (CONT.) A8.1 DOOR & WINDOW SCHEDULE UNIT TYPE A REFLECTED CEILING PLANS A5.1 A5.2 A6.1 STAIR SECTIONS OVERALL SITE DEMOLITION PLAN UNIT TYPE B FLOOR PLANS A3.1 UNIT TYPE B REFLECTED CEILING PLANS OVERALL BASEMENT REFLECTED CEILING PLAN BUILDING 1 ROOF PLAN UNIT TYPE B2 REFLECTED CEILING PLANS BUILDING SECTIONS BUILDING SECTIONS AD1 DETAILS AD2 DETAILS AD3 DETAILS HUNTINGTON DR. CHESTNUT AVE. COLORADO BLVD. MA Y F L O W E R A V E . EN C I N O A V E . 5T H A V E . 2N D A V E . 1S T A V E . SA N T A A N I T A A V E . SANTA CLARA ST. HUN T I N G T O N D R . GENOA ST. (MAP NOT TO SCALE) NORTH 210 PROJECT SITE A5.3 BUILDING SECTIONS AD4 DETAILS AD5 DETAILS CONTACT: IVAN CHIU EMAIL: XUBING7143@GMAIL.COM GRADING / DRAINAGE PLAN (1ST FLOOR) GRADING / DRAINAGE PLAN (BASEMENT) C-4 EROSION CONTROL AND DEMOLITION PLAN CODE OF DESIGN BASEMENT FOUNDATION PLAN BASEMENT FRAMING S2.1 STRUCTURAL DETAILS S2.2 STRUCTURAL DETAILS S2.5 SHORING DETAILS S1.7 S1.8 SHORING PLANS SHORING PLANS SURVEY S-1 SURVEY MAP 1 A0.7 CODE ANALYSIS BUILDING 1 EXTERIOR ELEVATIONS BUILDING 2 EXTERIOR ELEVATIONS A4.3 A4.4 A6.3 SITE SECTIONS Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update HERS INSPECTION FEATURES & MANDATORY RESIDENTIAL MEASURES SEE SHEETS M-0.1 THROUGH M-0.8 FOR HERS INSPECTION FEATURES & MANDATORY RESIDENTIAL MEASURES REQUIRED FOR THIS PROJECT PHOTOVOLTAIC SYSTEM IN LIEU OF SOLAR ZONES, GENERAL CONTRACTOR IS TO PROVIDE THERMOSTATS WITH DEMAND RESPONSE CONTROLS, WHOLE HOUSE FANS WITH ELECTRONICALLY COMMUTATED MOTORS, AND EV CHARGING READY PARKING SPACES IN ALL UNITS PER CEC SECTION 110.10(b)1B EXCEPTION 4 CODE OF DESIGN 3 3 CIVIL STRUCTURAL MECHANICAL PLANTING PLAN IRRIGATION PLAN L-1 L-2 DETAIL SHEETL-3 LANDSCAPE ENERGY CALCULATIONM-0.2 ENERGY CALCULATIONM-0.3 ENERGY CALCULATIONM-0.4 ENERGY CALCULATIONM-0.5 ENERGY CALCULATIONM-0.6 ENERGY CALCULATIONM-0.7 ENERGY CALCULATIONM-0.8 MECHANICAL LEGEND, NOTE, DETAIL, & SCHEDULEM-1 GARAGE VENTILATION PLANM-2 CONDITIONS OF APPROVAL A0.2 CONDITIONS OF APPROVAL Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update A0.3 CONDITIONS OF APPROVAL CONDITIONS OF APPROVAL (CONTINUED) Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update GENERAL NOTES A0.4 GENERAL NOTES CODESA. ALL WORK SHALL CONFORM TO ALL APPLICABLE FEDERAL STATE AND LOCAL CODES AND ORDINANCES. NOTHING SHOWN IN THESE DRAWINGS SHALL BE CONSTRUED AS PERMISSION TO VIOLATE ANY OF THE FOLLOWING: A. CALIFORNIA BUILDING CODE, 2022 EDITION. B. CALIFORNIA TITLE 24 ENERGY REGULATIONS 2022 EDITION. C. CALIFORNIA TITLE 24 TYPE V BUILDINGS CHAPTERS 2-22 2022 EDITION. D. APPLICABLE FEDERAL, STATE, COUNTY AND LOCAL ORDINANCES AND STATUTES. E. REQUIREMENTS OF THE CALIFORNIA DIVISION OF INDUSTRIAL SAFETY, DEPARTMENT OF OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION. F. 2022 CMC, 2022 CPC, 2022 CEC, 2022 CGC & 2022 CRC. PERMITSB. THE GENERAL BUILDING PERMIT AND PLAN CHECK FEE SHALL BE SECURED AND PAID FOR BY THE OWNER. ALL OTHER PERMITS SHALL BE TAKEN OUT AND PAID FOR BY THE SUB-CONTRACTOR DIRECTLY RESPONSIBLE. CONTRACTOR SHALL OBTAIN PERMITS FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY AS REQUIRED AND SHALL COMPLY WITH ALL REQUIREMENTS OF THE DIVISION. SEPARATE APPLICATION, PLAN CHECK, AND PERMITS ARE REQUIRED FOR: A. RETAINING WALLS B. BLOCK WALLS/FENCES C. ELECTRICAL WORK D. MECHANICAL WORK E. PLUMBING WORK F. DEMOLITION CONSTRUCTION DOCUMENTSC. THE INTENTION OF THESE DOCUMENTS IS TO INCLUDE ALL LABOR, MATERIALS, SERVICES, EQUIPMENT AND TRANSPORTATION NECESSARY FOR COMPLETE AND PROPER EXECUTION OF THE WORK INDICATED ON THE DRAWING OR REASONABLY INFERRED THERE FROM. THE ARCHITECT WILL IN NO WAY BE RESPONSIBLE FOR HOW THE FIELD WORK IS PERFORMED, SAFETY IN OR ABOUT THE JOBS SITE, METHODS OF PERFORMANCE OR TIMELINESS IN THE PERFORMANCE OF THE WORK. IF DISCREPANCY EXISTS BETWEEN 1/8" SCALE PLAN AND 1/4" SCALE PLAN OCCUR, IMMEDIATELY NOTIFY ARCHITECT OF SUCH DISCREPANCY BEFORE PROCEEDING WITH THE WORK. DIMENSIONS SHOWN ON PLANS AND DETAILS ARE TO FACE OF STUD (FOS), FACE OF MASONRY (FOM), FACE OF CONCRETE (FOC), UNLESS OTHERWISE INDICATED. WRITTEN DIMENSION SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THESE DRAWINGS. BIDS 1. BIDDERS PRIOR TO SUBMITTAL OF BIDS SHALL THOROUGHLY FAMILIARIZE THEMSELVES WITH THE ARCHITECT'S PLANS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCY, OMISSION, CLARIFICATION, OR ANY INFORMATION NECESSARY FOR COMPLETION OF THEIR SCOPE OF WORK. ANY ITEM NOT COVERED, SHOWN IN DRAWINGS, QUESTIONED, OR CLARIFIED PRIOR TO BIDDING THAT IS NECESSARY FOR PROPER EXECUTION AND COMPLETION OF ANY SCOPE OF WORK SHALL BE PROVIDED BY THE BIDDING CONTRACTOR AT HIS OWN EXPENSE. 2. TRADES SHALL FURNISH ALL LABOR, EQUIPMENT, MATERIALS AND SERVICES REQUIRED TO PERFORM ALL WORK NECESSARY, INDICATED OR REASONABLY INFERRED OR REQUIRED BY ANY CODE WITH JURISDICTION TO COMPLETE THEIR SCOPE OF WORK FOR A COMPLETE AND PROPERLY FINISHED JOB. 3. ALL TRADES SHALL VERIFY THE EXACT LOCATION OF ALL UTILITIES PRIOR TO BIDDING. FAILURE TO AQUIRE THE NECESSARY INFORMATION FOR UTILITY INSTALLATION SHALL CONSTITUTE THE REGECTION AND DENIAL OF ADDITION COSTS. 4. CONTRACTORS PRIOR TO BIDDING SHALL GUARANTEE THAT ALL OTHER SUB-BIDDERS OR SUB-CONTRACTORS SHALL BE GIVEN COMPLETE FULL SETS OF PLANS TO INSURE THAT THEY HAVE INCLUDED ALL ITEMS NECESSARY TO COMPLETE THEIR WORK. ANY ITEM MISSED BY THESE SUB-CONTRACTORS IN THEIR BIDS SHALL BE ABSORBED BY THE GENERAL CONTRACTOR AT HIS OWN EXPENSE AND IN NO WAY WILL EFFECT ANY ADDITIONAL COST OVER AND ABOVE THE FINAL BID. D. CONTRACTORE. 1. PRIOR TO COMMENCING CONSTRUCTION THE GENERAL CONTRACTOR SHAL VERIFY THAT ALL SUB-ONTRACTORS HAVE THE CURRENT SET OF "CONSTRUCTION DOCUMENTS". 2. , THE GENERAL CONTRACTOR AND ALL SUB-CONTRACTORS SHALL REVIEW ALL DRAWINGS AND SPECIFICATIONS AND VERIFY CONDITIONS AT THE SITE. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. ALL CLARIFICATION REQUESTED BY CONTRACTOR FROM THE ARCHITECT BEFORE OR AFTER COMMENCING OF WORK SHALL TAKE OUT LEAST FIVE WORKING DAYS. CONTRACTOR SHALL VERIFY WITH THE PROPER UTILITY COMPANY THE LOCATIONS OF ALL EXISTING BELOW GRADE UTILITIES AND THEIR SERVICE CONNECTIONS PRIOR TO THE COMMENCEMENT OF WORK. 3. NO CONTRACTOR, SUB-CONTRACTOR OR SUB SUB-CONTRACTOR IS TO START WORK UNTIL HE/ SHE HAS FIRST EXAMINED THE EXISTING CONDITIONS. IF FOR ANY REASON A PERFECT JOB IS IMPOSSIBLE, IT SHALL BE IMMEDIATELY REPORTED TO THE PROJECT SUPERINTENDENT AND ARCHITECT BEFORE PROCEEDING WITH THE WORK. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS, FOR SELECTING FABRICATION PROCESSES, FOR TECHNIQUES OF ASSEMBLY, FOR COORDINATION OF HIS WORK WITH THAT OF OTHER TRADES AND FOR PERFORMING ALL WORK IN A SAFE AND SATISFACTORY MANNER. 5. CONTRACTOR TO VERIFY AND ENSURE AVAILABILITY AND TIMELY DELIVERY OF SPECIFIED OR SUBSTITUTED PRODUCTS PRIOR TO CONSTRUCTION. HE SHALL NOTIFY ARCHITECT OF POSSIBLE CHANGES TO CONSTRUCTION DOCUMENTS OR CONSTRUCTION DELAY DUE TO NON AVAILABILITY OR LATE DELIVERY OF MATERIALS. ARCHITECT IS NOT RESPONSIBLE FOR NON AVAILABILITY OR LATE DELIVERY OF PRODUCTS DURING CONSTRUCTION. 6. ANY CONTRACTOR PRIOR TO INSTALLATION OR PROCUREMENT OF MATERIALS SHALL NOTIFY ARCHITECT OF PROBLEMS IF ANY. FAILURE TO DO SO SHALL MEAN THAT ALL NECESSARY CORRECTIVE MEASURE, DOCUMENTATION, ETC. SHALL BE DONE BY THAT CONTRACTOR AT HIS OWN EXPENSE AND TIME. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURACY OF THE BUILDING LINES AND LEVELS. THE CONTRACTOR SHALL COMPARE CAREFULLY THE LINES AND LEVELS SHOW ON THE DRAWINGS WITH EXISTING LEVELS FOR THE CONSTRUCTION OF THE WORK AND SHALL CALL THE ARCHITECT'S ATTENTION TO ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK. 8. DIVISION OF INDUSTRIAL SAFETY: CONTRACTOR SHALL OBTAIN PERMITS FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY AS REQUIRED AND SHALL COMPLY WITH ALL REQUIREMENTS OF THE DIVISION. 9. SUBSTITUTION: NO SUBSTITUTION SHALL BE MADE WITHOUT THE OWNER'S APPROVAL. 10. CHANGES: THE OWNER MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO, OR DEDUCTING FROM THE WORK; THE CONTRACTOR SUM BEING ADJUSTED ACCORDINGLY. 11. CUTTING AND PATCHING: ALL TRADES SHALL DO THEIR OWN CUTTING, FITTING, PATCHING ETC. TO MAKE THE SEVERAL PARTS COME TOGETHER PROPERLY AND FIT IT TO RECEIVE OR BE RECEIVED BY WORK OF OTHER TRADES. 12. THE CONTRACTOR SHALL DAILY CLEAN-UP AND WEEKLY REMOVE AND DISPOSE IN A LEGAL MANNER OF ALL DEBRIS AND WASTE ATTRIBUTED TO THE JOB AND SITE. 13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACEMENT OF REPAIR, WITHOUT ADDITIONAL DAMAGE, FOR ANY DAMAGE CAUSED BY THE GENERL CONTRACTOR OR HIS SUB-CONTRACTOR. 14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REPLACE OR REMEDY ANY FAULTY, IMPROPER OR INFERIOR MATERIALS OR WORKMANSHIP OR ANY DAMAGE TO THEIR WORK RESULTING THERE-FROM, WITHOUT COST TO OWNER, WHICH SHALL APPEAR WITHIN ONE YEAR AFTER THE COMPLETION AND ACCEPTANCE OF THE WORK UNDER THIS CONTRACT. 15. THE TERM 'CONTRACTOR' AS USED HEREIN AND ON THE DRAWINGS SHALL ALSO BE APPLICABLE TO EACH SUB-CONTRACTOR AS REQUIREMENTS PERTAIN TO HIS TRADE. 16. CONTRACTOR SHALL SUBMIT COPIES OF MANUFACTURER'S CATALOG CUTSHEETS, BROCHURES, MANUFACTURER SHEETS, SAMPLES, INSTALLATION INSTRUCTION, ETC. REGARDING MANUFACTURED PRODUCTS USED OR INSTALLED IN THE PROJECT FOR OWNER'S REVIEW AND ACCEPTANCE BEFORE PURCHASE OR DELIVERY TO THE SITE. NON-COMPLIANCE MAY RESULT IN REJECTION AND DEEMED NON-ACCEPTANCE. 17. MATERIALS AND PRODUCTS SHALL BE DELIVERED TO THE BUILDING SITE IN ORIGINAL PACKAGES. MATERIALS AND PRODUCTS SHALL BE STORED OFF THE GROUND ON WOOD BLOCKING IN AN UPRIGHT POSITION, PROTECTED FROM THE ELEMENTS, IN A MANNER TO PREVENT DAMAGE SUCH AS MARRING, SCRATCHING AND NOT LIMITED TO DELAMINATION OF FINISHES. 18. ALL BRACING NECESSARY FOR CONSTRUCTION PURPOSES SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 19. WHERE NO CONSTRUCTION DETAILS ARE SHOWN OR NOTED FOR A PART OF THE WORK, CONTRACTOR SHALL ASSUME THE MOST STRINGENT CONDITION AMONG INDUSTRY STANDARDS AND OR THE COMMON PRACTICE OF THAT PARTICULAR CONDITION. LIABILITIESF. THE DESIGN PROFESSIONAL (DP) SHALL CONSULT WITH THE CLIENT REGARDING THE PROBABLE SERVICES REQUIRED TO COMPLY WITH AMERICAN DISABILITIES ACT (ADA). THE DP IS NOT AN ATTORNEY NOR SHOULD THE DP'S RENDERING AN OPINION OF PROBABLE SERVICES REQUIREMENTS BE CONSIDERED EQUIVALENT TO A LEGAL INTERPRETATION OF ADA. THE DP'S OPINION WILL BE BASED SOLELY ON HIS OR HER OWN EXPERIENCE AND KNOWLEDGE. THIS REQUIRES THE DP TO MAKE A CERTAIN NUMBER OF ASSUMPTIONS AS TO THE TYPES OF DISABILITIES COVERED BY ADA, THE DEGREE OF ACCESS THAT IS "READILY ACHIEVABLE" AND WHAT CONSTITUTES "REALITY ACCESSIBLE AND USABLE." GIVEN THE ASSUMPTIONS WHICH MUST BE MADE, THE DP CANNOT AND DOES NOT GUARANTEE THE ACCURACY OF HIS OR HER OPINION AS TO FULL COMPLIANCE AND IN RECOGNITION OF THAT FACT, THE CLIENT WAIVES ANY CLAIM AGAINST THE DP RELATIVE TO THE ADEQUACY OF THE OPINION TO FULLY COMPLY WITH ADA REQUIREMENTS. THE ARCHITECT WHO SIGNS THESE PLANS, SPECIFICATIONS AND INSTRUMENTS OF SERVICE SHALL NOT BE HELD RESPONSIBLE FOR DAMAGES RESULTING FROM CHANGES OR USES NOT AUTHORIZED OR APPROVED BY THE ARCHITECT. THE SIGNING OF THESE DOCUMENTS WILL NOT IMPOSE A LEGAL DUTY OR RESPONSIBILITY TO OBSERVE THE CONSTRUCTION OF THE FIXED WORKS SUBJECT TO THESE DOCUMENTS. INSULATION NOTESG. 1. ROOF / CEILING INSULATION SHALL BE R-38, ROCKWOOL OR FIBERGLASS, BATT INSULATION BETWEEN BOTTOM CHORDS OF ROOF TRUSSES OR ROOF JOISTS, U.N.O. 2. ALL EXTERIOR / INTERIOR WALLS SHALL BE R-21, ROCKWOOL OR FIBERGLASS, BATT INSULATION BETWEEN STUDS, U.N.O. 3. ALL RAISED WOOD FLOOR STRUCTURE SHALL BE INSULATED W/ R-19 ROCKWOOL OR FIBERGLASS, BATT INSULATION BETWEEN FLOOR JOIST, U.N.O. 4. ALL PARTY AND CORRIDOR WALLS SHALL BE INSULATED PER WALL SCHEDULE / LEGEND. 5. ALL PLUMBING WALLS AND WALLS SURROUNDING AND SEPARATING BATHS AND TOILETS FACILITIES FROM OTHER ROOMS SHALL HAVE SOUND ATTENUATION BATT INSULATION DESIGNED TO DELIVER NOISE CONTROL SUCH AS R-13 ROCKWOOL OR FIBERGLASS, BATT INSULATION BETWEEN STUDS AND CEILING WHERE OCCURS, U.N.O. 6. HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE WRAPPED WITH AN APPROVED INSULATION. 7. SECURE AND INSULATE ALL 1ST. AND 2ND. BATHROOM WALL , FLOORS AND WASTE PIPES FOR SOUND TRANSMISSION. 8. EXPOSED HOT WATER PIPING UNDER LAVATORIES SHALL BE WRAPPED WITH INSULATION. ROOF NOTESH. 1. ALL ROOF CONSTRUCTION AND COVERINGS SHALL BE PER CHAPTER 9 & 15 OF THE 2022 CALIFORNIA BUILDING CODE (CBC). 2. ALL SHEET METAL ROOF WORK SHALL BE PER CHAPTER 15 OF THE 2022 CALIFORNIA BUILDING CODE (CBC). 3. FLASH AND COUNTER FLASH AROUND ROOF PENETRATIONS AS REQUIRED. 4. INSTALL ROOFING MATERIALS IN ACCORDANCE WITH ALL MANUFACTURER'S WRITTEN SPECIFICATIONS AND RECOMMENDATIONS. 5. TILE ROOFING SHALL BE ASPHALT SHINGLE TILING. 1. THIS PROJECT'S SITE IS IN CLIMATE ZONE 9. 2. USE COMPUTER PROGRAM DESIGN ANALYSIS METHOD TO COMPLY WITH ENERGY REQUIREMENT. SEE ENERGY CALCULATIONS. 3. ALL HEATING, VENTILATING, AIR CONDITIONING, AND WATER HEATING EQUIPMENT SHALL MEET ALL REQUIREMENTS OF APPLIANCE EFFICIENCY STANDARDS AND BE CERTIFIED BY CALIFORNIA ENERGY COMMISSION. 4. THERMOSTATS SHALL BE EQUIPPED WITH AUTOMATIC SETBACK, WHICH OCCUPANT CAN PROGRAM TO AUTOMATICALLY SET BACK THE THERMOSTAT TWICE IN 24 HOURS. 5. EQUIPMENT WHICH REQUIRES PREVENTIVE MAINTENANCE TO MAINTAIN EFFICIENT OPERATION SHALL BE FURNISHED TO THE OWNER WITH COMPLETE NECESSARY MAINTENANCE INFORMATION. 6. ALL FAN SYSTEMS EXHAUSTING AIR TO OUTSIDE SHALL BE PROVIDED WITH AUTOMATIC BACKDRAFT DAMPERS. 7. ALL TRANSVERSE DUCT, PLENUM, AND FITTING JOINTS SHALL BE SEALED WITH PRESSURE SENSITIVE TAPE OR MASTIC TO PREVENT AIR LOSS AND SHALL BE INSULATED. 8. ALL MANUFACTURED WINDOWS AND SLIDING GLASS DOORS SHALL MEET THE ANSI AIR FILTRATION STANDARDS AND SHALL BE CERTIFIED AND LABELED. I.ENERGY CONSERVATION NOTES 9. ALL SWINGING DOORS AND WINDOWS LEADING TO UNCONDITIONED AREAS SHALL BE FULLY WEATHER-STRIPPED. 10. STORAGE TYPE WATER HEATERS SHALL BE EXTERNALLY WRAPPED WITH R-12 INSULATION OR GREATER. 11. THE FIVE FEET OF PIPE CLOSEST TO THE WATER HEATER, IF OUTSIDE CONDITIONED SPACE, SHALL BE INSULATED WITH A MINIMUM OF R-6 STEAM AND STEAM CONDENSATION RETURN PIPING AND RECALCULATING HOT WATER PIPING OUTSIDE THE BUILDING ENVELOPE SHALL BE INSULATED IN ACCORDANCE WITH T-20-1406. (D). 12. LAMPS USED IN LUMINARIES FOR GENERAL LIGHTING IN KITCHENS AND BATHROOMS SHALL HAVE AN EFFICIENCY OF NOT LESS THAN 40 LUMENS PER WATT. 13. SHOWER HEAD AND FAUCETS SHALL BE EQUIPPED WITH FLOW RESTRUCTURES AS OUTLINED IN THE APPLIANCE EFFICIENCY STANDARDS AND SHALL BE CERTIFIED BY THE CALIFORNIA ENERGY COMMISSION. 14. ALL INSULATION USED SHALL COMPLY WITH CALIFORNIA QUALITY STANDARDS. 15. AFTER INSTALLING INSULATION THE INSTALLER SHALL POST IN A CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THE INSTALLER AND THE BUILDER STATING THAT THE INSTALLATION CONFORMS TO THE REQUIREMENTS OF TITLE 24, PART 2, CHAPTER 2-33, AND THAT THE MATERIALS INSTALLED CONFORM WITH THE REQUIREMENTS OF TITLE 20,CHAPTER 2, SUBCHAPTER 4, ARTICLE 3. THE CERTIFICATE SHALL STATE THE MANUFACTURER'S NAME AND MATERIAL IDENTIFICATION, THE INSTALLED "R" VALUE, AND (IN APPLICATION OF LOOSE FILL INSULATION) THE MINIMUM INSTALLED WEIGHT PER SQUARE FOOT CONSISTENT WITH THE MANUFACTURER'S LABELED DENSITY FOR THE DESIRED "R" VALUE, N.E.T. 16. FOR INFILTRATION CONTROL, ALL OPENINGS AND PENETRATIONS MUST BE CAULKED AND SEALED, SUCH AS AROUND WINDOWS, AT SOLE PLATES AND OPENINGS FOR UTILITY PIPES AND WIRES (AND/OR SHOWN ON PLANS). 17. DUCTWORK MUST COMPLY WITH CHAPTER 6, 2022 CALIFORNIA MECHANICAL CODE (CMC). 18. FACTORY BUILT FIREPLACES MUST HAVE CLOSABLE METAL OR GLASS DOORS COVERING FIRE BOX OPENINGS. COMBUSTION AIR INTAKE DUCTS ARE REQUIRED (SIX SQUARE INCHES MINIMUM) WITH DAMPERS, FLUE DAMPERS ARE ALSO REQUIRED. 19. PERMANENT VACUUM BREAKERS SHALL BE INCLUDED WITH BALL HOSE BIBBS. THE STATE OF CALIFORNIA ENERGY CONSERVATION STANDARDS SECTIONS OF TITLE 24 OF THE CALIFORNIA ADMINISTRATIVE CODE HAVE BEEN REVIEWED AND THE DESIGN SUBMITTED SUBSTANTIALLY CONFORMS TO THE ENERGY REGULATIONS FOR NON-RESIDENTIAL AND RESIDENTIAL BUILDINGS. 20. ALL FIREPLACES SHALL BE EQUIPPED WITH GLASS DOORS IN COMPLIANCE WITH TITLE 24 ENERGY CONSERVATION REGULATIONS. GENERAL PROVISIONSJ. 1. PROVIDE SHEET METAL DRYER VENT TO EXTERIOR. PROVIDE RECESSED WALL WATER SUPPLY AND DRAIN FOR WASHING MACHINE. AT SECOND FLOOR LOCATIONS PROVIDE SHEET METAL DRAIN PAN WITH 1" DRAIN LINE TO APPROVED PLUMBING RECEPTOR. 2. PROVIDE MAILBOX UNIT EQUAL TO SURFACE MOUNTED U.S.P.S. APPROVED UNIT MODEL WITH NEWSPAPER RECEPTACLE, INDIVIDUAL LOCKABLE COMPARTMENTS. 3. PROVIDE BUILDING ADDRESS AND UNIT NUMBER IDENTIFICATION, STYLE TO BE APPROVED BY OWNER. 4. BUILDING ADDRESS MUST BE PROVIDED ON THE FRONT OF THE BUILDING. NUMBERS MUST BE VISIBLE FROM THE STREET, MUST BE OF A COLOR, WHICH CONTRASTS WITH THE BACKGROUND AND MUST BE AT LEAST 4" IN HEIGHT AND 2" IN WIDTH. 5. FIREPLACE TO BE EQUAL TO 'EARTHCORE INDUSTRIES, LLC' ISOKERN STANDARD MODEL FIREPLACE & CHIMNEY SYSTEM (ICC ESR-2316). PROVIDE GLASS DOORS AND OUTSIDE AIR INTAKES. 6. GAS FIRED WATER HEATER TO BE EQUAL TO A.O. SMITH BT-100 (C.E.C. APPROVED). PROVIDED B-VENT THROUGH ROOF AND P.T. DISCHARGE LINE TO EXTERIOR. WATER HEATERS SHALL BE SEISMIC STRAPPED. 7. ALL UTILITIES MUST BE PLACED UNDERGROUND. ALL CABLES, WIRES, CONDUIT SYSTEMS AND PIPING OUTSIDE BUILDINGS OR STRUCTURES AND WITHIN THE EXTERIOR PROPERTY LINES SHALL BE INSTALLED UNDERGROUND OTHER THAN RISERS IMMEDIATELY ADJACENT AND ATTACHED TO THE BUILDING. 8. FOR CONCRETE, SPECIAL INSPECTION IS REQUIRED IN ACCORDANCE W/ 2022 CBC SECTION 1704A.4 (EXCEPT WHEN WAIVED PER SAID CBC SECTION). 9. DRIVEWAY GRADES AND FORMS SHALL BE INSPECTED AND APPROVED PRIOR TO PLACING CONCRETE. 10. NO WATER SERVICE LATERAL, METER OR FLUSH OUT SHALL BE PERMITTED IN ANY DRIVEWAY, NOR SHALL THEY BE LOCATED LESS THAN 3' FROM THE TOP OF "X" OF ANY DRIVEWAY OR OTHER UTILITY INSTALLATION. 11. MECHANICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO HEATING AND AIR CONDITIONING DEVICES SHALL NOT BE PERMITTED IN ANY REQUIRED FRONT, SIDE OR REAR YEAR. SAID EQUIPMENT SHALL NOT PRODUCE A SOUND LEVEL IN EXCESS OF 55 DBA. 12. PROVIDE ADDITIONAL PROTECTIVE BARRIERS ON GARAGE WALLS, SO LOCATED AS TO PROTECT THE WALL FINISHES OF WOODEN FRAME CONSTRUCTION FROM DAMAGE BY AUTOMOBILES. 13. A SMOKE DETECTOR SHALL BE INSTALLED IN ALL BASEMENTS, BASEMENT GARAGES, ATTACHED GARAGES AND ATTACHED AND COVERED PARKING SPACES OF DWELLING UNITS. SUCH DETECTOR SHALL BE CONNECTED TO A SOUNDING DEVICE OR OTHER DETECTOR TO PROVIDE AN ALARM WHICH WILL BE AUDIBLE IN THE SLEEPING AREAS. 14. DEFERRED SUBMITTALS (TRUSSES, FABRICATED STAIRS/GUARDRAILS, ETC.) MUST BE REVIEWED, SIGNED, AND STAMPED BY ARCHITECT OR ENGINEER OF RECORD PRIOR SUBMITTAL TO THE BUILDING DIVISION, AND SHALL BE REVIEWED AND APPROVED BY THE CITY PRIOR TO INSTALLATION. CBC 106.3.4.2. 15.ALL GLAZING SHALL BEAR THE MANUFACTURER'S MARK DESIGNATING THE TYPE AND THICKNESS OF THE GLASS OR GLAZING MATERIAL. THE IDENTIFICATION SHALL NOT BE OMITTED UNLESS APPROVED AND SHALL BE IN ACCORDANCE WITH APPROVED CONSTRUCTION DOCUMENTS THAT COMPLY WITH THE PROVISIONS OF CBC CHAPTER 24. 16. SAFETY GLAZING SHALL BE IDENTIFIED IN ACCORDANCE WITH CHAPTER 24, SECTION 2406.3. EACH PANE OF TEMPERED GLASS, EXCEPT TEMPERED SPANDREL GLASS, SHALL BE PERMANENTLY IDENTIFIED BY THE MANUFACTURER. THE IDENTIFICATION MARK SHALL BE ACID ETCHED, SAND BLASTED, CERAMIC FIRED, LASER ETCHED, EMBOSSED OR OF A TYPE THAT, ONCE APPLIED, CANNOT BE REMOVED WITHOUT BEING DESTROYED. BATHROOM PROVISION NOTESK. 1. PROVIDE GFI PROTECTION AT OUTLETS AS REQUIRED. 2. PROVIDE EXHAUST FAN WITH SWITCH AT ALL BATHROOMS WHERE REQUIRED. 3. PROVIDE HIGH EFFICACY LIGHT FIXTURE OVER MIRROR WHERE OCCUR. 4. PROVIDE HEAT LAMP AS REQUIRED. 5. PROVIDED 30"X48" CLEARANCE IN FRONT OF WATER CLOSETS, EXCEPT AT FIRST FLOOR BATHROOMS WHERE A 30"X48" CLEARANCE SHALL BE PROVIDED WITHIN BATHROOM. 6. CEMENT, FIBER-CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C1178, C1288 OR C1325 SHALL BE USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN SHOWER AREAS. WATER-RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A BASE FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840. REGULAR GYPSUM WALLBOARD IS PERMITTED UNDER TILE OR WALL PANELS IN OTHER WALL AND CEILING AREAS WHEN INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840. WATER-RESISTANT GYPSUM BOARD SHALL NOT BE USED IN THE FOLLOWING LOCATIONS: (2509.2) A. OVER A VAPOR RETARDER. B. IN AREAS SUBJECT TO CONTINUOUS HIGH HUMIDITY, SUCH AS SAUNAS, STEAM ROOMS OR GANG SHOWER ROOMS. C. ON CEILINGS WHERE FRAME SPACING EXCEEDS 12" O.C. FOR 1/2" THICK AND MORE THAN 16" O.C. FOR 5/8" THICK. 7. COUNTER TOP SHALL BE SIMULATED MARBLE AS MIN. REQUIRED, SPECIFIC TYPE PER PLAN OR BY OWNER. 8. PROVIDE WATER CLOSET SEATS AND RECESSED WATER SUPPLY UNITS. 9. WATER CLOSET SHALL BE "ULTRA LOW FLUSH" TYPE WITH 1.6 GALLONS MAX. PER FLUSH. 10. MEDICINE CABINETS SHALL BE FRAMELESS. 11. PROVIDE TOILET PAPER HOLDER, RECESS IN CABINET. 12. PROVIDE 30" TOWEL BAR AT EACH BATHROOM. 13. PROVIDE A ROBE HOOK, DOOR STOP TYPE ON BATH DOORS. 14. BATH TUB TRAP SHALL BE RIGID-TYPE CONNECTION. 15. PROVIDE MECHANICAL VENTILATION CAPABLE OF PROVIDING FIVE AIR CHANGES PER HOUR IN BATHROOMS CONTAINING TUBS OR SHOWERS, LAUNDRY ROOMS, AND SIMILAR ROOMS IF REQUIRED OPERABLE WINDOWS ARE NOT PROVIDED (DUCTLESS FANS ARE NOT ACCEPTABLE IN ROOM CONTAINING TUBS OR SHOWERS). (1203-3) KITCHEN PROVISION NOTESL. 1. PROVIDE MICROWAVE OVEN AND 220V OUTLET. 2. PROVIDE SPACE FOR 14 TO 18 CUBIC FOOT REFRIGERATOR, TWO (2) DOOR UNIT. 3. RANGE TO BE GAS 36" WITH DROP-IN COUNTER TOP. PROVIDE 220V OUTLET. 4. RANGE HOOD SHALL BE GE STANDARD RANGE HOOD JV332J, W/2-SPEED FAN AND COOKTOP LIGHT, VENT TO OUTSIDE OR EQ, TO BE APPROVED BY OWNER AND CITY BLDG. DEPT. PROVIDE 110V OUTLET. 5. PROVIDE OUTLET FOR DISHWASHER, DISHWASHER TO BE 24" FIVE (5) CYCLE. 6. PROVIDE OUTLET FOR FOOD WASTE DISPOSAL. DISPOSAL TO BE 1/2 HORSE POWER SOUND INSULATED MODEL. 7. PROVIDE GFI OUTLETS WITHIN SIX (6) FEET OF KITCHEN SINK, AND 4 FEET ON-CENTER AT COUNTER AND ISLAND. 8. KITCHEN SINK TO BE DOUBLE COMPARTMENT WHITE ENAMEL UNIT. 9. ALL CABINET TO HAVE STAIN GRADE FINISH. 10. PROVIDE HIGH EFFICACY FIXTURES UNDER OVERHEAD CABINETS PER REFLECTED CEILING PLAN. 11. COUNTER TOPS TO BE STONE WITH INTEGRAL SPLASH AS MIN. REQUIRED. SPECIFIC TYPE PER PLAN OR BY OWNER. MISC. CONSTRUCTION NOTESM. 1. LATH, PLASTER AND DRYWALL SPECIFICATION SHALL CONFORM TO THE REQUIREMENTS OF 2022 CBC CHAPTER 25. GYPSUM BOARD AND PLASTER SHALL BE NAILED TO ALL STUDS AND TO TOP AND BOTTOM PLATES. 2. USE 2-15# FELT BACKING WHEN STUCCO IS APPLIED O/ PLYWOOD IN ACCORDANCE W/ 2022 CBC SECTION 2510.6. 3. ALL INTERIOR SURFACES OF WALLS AND CEIL'G SHALL BE COVERED W/ PLASTER, MIN. THK. 7/8" INCHES (22.23MM.) OR GYPSUM WALLBOARD, MIN. THICKNESS 5/8" (15.88 MM.) OR MATERIALS EQUAL IN RIGIDITY AND FIRE RESISTANCE AS APPROVED BY THE BUILDING OFFICIAL. 4. INSPECTION OF NAILING REQUIRED FOR DRYWALL AND ALL LATH WHEN IN PLACE IN ACCORDANCE WITH 2022 CBC SECTION 2503. 5. PROVIDE WEEP SCREED BELOW FOUNDATION PLATE LINE & 4" ABOVE GRADE ON ALL EXTERIOR STUD WALLS IN ACCORDANCE W/ 2022 CBC SECTION 2512.1.2. 6. SEPARATE ELECTRICAL, PLUMBING AND MECHANICAL EQUIPMENT AND/OR SYSTEMS WILL BE COMPLETELY SEPARATE FOR EACH UNIT. PROVIDE SEPERATE UTILITY METERS FOR EACH UNIT. 7. THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND, OR OBTAIN NECESSARY PERMIT FORM STATE OF CALIFORNIA, DIVISION OF INDUSTRIAL SAFETY PRIOR TO THE ISSUANCE OF A BUILDING OR GRADING PERMIT. 8. PROVIDE SUBDRAINS. 9. RETAINING WALLS SHALL BE WATERPROOF BEFORE BACKFILLING AT BUILDING WHERE OCCURS. 10.ENCLOSED ATTIC AND ENCLOSED RAFTER SPACES FORMED WHERE CEILING ARE APPLIED DIRECTLY TO THE UNDER SIDE OF ROOF RAFTER SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATION OPENING PROTECTED AGAINST THE ENTRANCE OF RAIN SNOW. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/300 OF THE AREA OF THE SPACE VENTILATED. MIN. 50% OF THE VENTILATING AREA WILL BE PROVIDED BY EAVES VENT, AND 50% WILL BE PROVIDED BY DORMER VENT LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3' ABV. EAVES OR CORNICE VENTS. 11. SMOKE DETECTORS SHALL BE CONNECTED TO THE BUILDING WIRING SYSTEM IN ALL NEW CONSTRUCTION AND ADDITION WITH A VALUATION OVER 41,000, AND BE PROVIDED WITH BATTERY BACK UP (2022 CBC SECTION 907.2.10.2). 12. SMOKE DETECTORS SHALL SOUND AN ALARM AUDIBLE IN ALL AREAS OF THE BUILDING OR BE INTERCONNECTED (2022 CBC SECTION 907.2.10.3). 13. BUILDING PERMIT APPLICATION THAT INVOLVES COMPLETE DEMOLITION OR DEMOLITION OF PART OF THE EXISTING STRUCTURE AND REMOVAL FROM SITE NEEDS WRITTEN APPROVAL FROM THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) (909) 396-2000 PER RULE 1403 FOR THE PROPER DISPOSAL OF ASBESTOS. 1. THE CENTER OF 15-,20- AND 30-AMPERE RECEPTACLES SHALL BE INSTALLED WITHIN 12 TO 15 INCHES ABOVE THE FLOOR OR WORKING SURFACE PER TITLE 24 AMENDMENT. 2. IN A CLOSET, SURFACE MOUNTED LIGHT FIXTURES SHALL BE AT LEAST 18 INCHES FROM A STORAGE AREA AND FLUSH MOUNTED LIGHTING FIXTURES SHALL BE AT LEAST 6 INCHES FROM A STORAGE AREA. ALL SHALL BE PROVIDED W/ PROTECTIVE COVER. 3. GROUND-FAULT CIRCUIT-INTERRUPTER (GFI) PROTECTED ELECTRICAL RECEPTACLES SHALL BE PROVIDED AT ALL RECEPTACLES AS FOLLOWS: A) INSTALLED IN A BATHROOM B) INSTALLED IN A GARAGE & BASEMENT C) EXTERIOR & CRAWL SPACE D) WITHIN 6FT. OF A KITCHEN SINK AND 4FT. ON CENTER AT COUNTER AND ISLAND. 4. ELECTRICAL RECEPTACLES INSTALLED OUTDOORS WHERE EXPOSED TO WEATHER SHALL BE IN A WEATHERPROOF ENCLOSURE. 5. LOCATION FOR ALL NEW ELECTRICAL SERVICES SHALL BE REQ. PER EDISON CO. 6. SMOKE DETECTORS MUST RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING, INTERCONNECTED, AND SHALL BE EQUIPPED WITH A BATTERY BACKUP. 7. ANY FIXED APPLIANCE SUCH AS DISPOSAL, DISHWASHER, CLOTHES WASHER, DRYER, BUILT-IN HEATERS, OR ANY OTHER FIXED APPLIANCE WITH 1.4 H.P. MOTOR OR LARGER, SHALL BE ON A SEPARATE #12 AWG WIRE BRANCH CIRCUIT. EACH DWELLING UNIT SHALL HAVE INSTALLED THEREIN AN INDIVIDUAL DISPOSAL CIRCUIT SUPPLIED WITH MINIMUM #12 AWG WIRE AND A 15 AMP INDICATING-TYPE SWITCH. 8. EACH KITCHEN SHALL BE PROVIDED WITH A SEPARATE FOOD WASTE GRINDER BRANCH CIRCUIT. 9. ALUMINUM CONDUCTORS SMALLER THAT NO. 4 A.W.G. REQUIRE CONTINUOUS INSPECTION BY A SPECIAL INSPECTOR APPROVED BY THE BUILDING OFFICIAL. 10. PROVIDE EXHAUST FAN W/ 50 CFM MIN. PER TABLE 4-4 CMC IN BATHROOMS CONTAINING TUBS OR SHOWERS, LAUNDRY ROOMS, AND SIMILAR ROOMS IF REQUIRED OR WHEN OPERABLE WINDOWS ARE NOT PROVIDED. 11. GENERAL LIGHTING IN KITCHENS SHALL HAVE AN EFFICIENCY OF NOT LESS THAN 40 LUMENS PER WATT (FLUORESCENT). 12. RECEPTACLE OUTLETS SHALL BE LOCATED WITHIN 12 TO 15 INCHES OF THE FLOOR. 13. LIGHT SWITCHES SHALL BE INSTALLED WITHIN 34 TO 48 INCHES OF THE FLOOR. 14. THERE SHALL BE A DISTRIBUTION PANEL IN, AND FOR EACH UNIT. FEEDERS FOR SUBPANELS SHALL BE ENCLOSED IN AN APPROVED RACEWAY. 15. THERE SHALL BE NO MORE THAN SIX DISCONNECTING MEANS PER SERVICE, GROUPED IN ANY ONE LOCATION WITHOUT A MAIN DISCONNECT. 16. GROUNDING ELECTRODE ENCASED BY A MINIMUM 2" OF CONCRETE AND LOCATED NEAR THE BOTTOM OF THE FOOTING AT GRADE. THE ELECTRODE SHALL BE BARE COPPER SIZED IN ACCORDANCE WITH 2022 CEC TABLE 250.66 AND ARTICLES 250.50 - 250.70. CONCRETE ENCASED ELECTRODE BARE COPPER WIRE SIZEDPER 2022 CEC TABLE 250.66TO REACH THE NEUTRAL LUGOF THE ELECTRICAL SERVICE CONCRETE OR MASONRY STRUCTURE ENOUGH TO REACH THE NEUTRAL2022 CEC TABLE 250.66 AND LONGBARE COPPER WIRE SIZED PER CONCRETE FOOTING CONCRETE FOOTING LUG OF THE ELECTRICAL SERVICE 1. METAL WATER PIPING. WOOD FRAME STRUCTURE PROVIDE AND INDICATE ON THE DRAWINGSTHE FOLLOWING ELECTRICAL GROUNDING 2. CONCRETE ENCASED ELECTRODE (BARE COPPER WIRE SIZED PER 2022 CEC 250.66). PANEL WITHOUT SPLICING. PANEL WITHOUT SPLICING. ELECTRODE SYSTEM PER 2022 CEC. 17. RECEPTACLE OUTLETS SHALL BE LOCATED WITHIN 15 TO 48 INCHES OF THE FLOOR. 18. NO POINT ALONG THE WALL IS FURTHER THAN 6 FEET FROM A RECEPTACLE. 19. PROVIDE A MIN. OF 100 AMP. ELEC. SERVICE PANEL WITH 1/2" DIA. X 20' LONG REBAR FOR BACKUP UNDER GROUND BONDED TO COLD WATER PIPE. PLEASE CONTACT EDISON FOR METER LOCATION AND UNDERGROUND SERVICE IF REQUIRED. 20. PROVIDE OUTDOOR RECEPTACLE OUTLET WITH WEATHERPROOF COVER AND GROUND FAULT CIRCUIT INTERRUPTER (GFCI) AT FRONT AND REAR OF DWELLING UNIT. 21. HEATING AND COOLING EQUIPMENT SHALL BE PROVIDED AN ELECTRICAL RECEPTACLE AND SWITCH CONTROLLED LIGHTING FIXTURE. THE RECEPTACLE SHALL BE INSTALLED WITHIN 25'-0" OF HEATING, AND COOLING EQUIPMENT. THE LIGHTING FIXTURE SHALL BE CONTROLLED BY A SWITCH LOCATED AT THE PASSAGEWAY LEADING TO THE HEATING OR COOLING EQUIPMENT AND SHALL BE PROVIDED AT THE POINT OF ENTRY TO THE ATTIC OR UNDERFLOOR SPACE HOUSING SUCH EQUIPMENT. 2022 CEC ARTICLES 210-63 AND 210-70(C). 22. COMPLY WITH 2022 CEC SEC. 311.8 REGARDING ELECTRICAL APPURTENANCES (I.E. ELECTRICAL PANELS, OUTLETS, MOTORS, ETC.), 18" MIN. ABOVE FINISH FLOOR. 30" COMBUSTION AIR INTAKE (W/ 1/4" MESH SCREEN)100 SQ-IN. NET TYP. FOR EA. UNIT, SEE ARCH. 20" MAX. 5'- 0 " M I N . SE E S E C . 9 0 6 ( B ) 30"X30" ACCESS DRWGS. FOR DETAILS. OPENING WARM AIRFURNACE LIGHT OVER CONTROLS DISCONNECT SEE SEC. 509PROVIDE POSITIVE ELECTRICAL LIGHT SWITCH WORKING SPACE AT CONTROLS SEC. 509 ALSO REQUIRE'S CONVENIENCE OUTLET(RECEPTACLE) WITHIN 25'OF EQUIPMENT 24" WIDE SOLIDFLR'G ACCESS WAY FIGURE 708-1. RELATED CODE SECTIONS: 509, 708. CENTRAL WARM-AIR FURNACES INSTALLED IN ATTIC MUST BE ACCESSIBLE FOR ROUTINE INSPECTION AND MAINTENANCE BY THE OWNER/OCCUPANT AND FOR SERVICE AND REPAIR AS NEEDED. CHANGING FILTERS, LUBRICATING MOTOR AND FAN BEARINGS, CHECKING BELT TENSION, AND RELIGHTING THE PILOT FOLLOWING A SERVICE INTERRUPTION ARE NORMAL OWNER FUNCTIONS. ADEQUATE LIGHT, AN ELECTRICAL OUTLET, SAFE ACCESS WAY AND SUFFICIENT WORKING SPACE ON THE CONTROL SIDE ALL ENCOURAGE AND FACILITATE MAINTENANCE AND ALSO ENABLE RAPID EGRESS IN AN EMERGENCY. 1. ATTIC FURNACE SHALL HAVE A. DOUBLE JOIST SUPPORTING UNIT B. LEVEL PLATFORM C. SEISMIC SWAY BRACE OR ANCHOR UNIT TO PLATFORM D. 30" MIN. ACCESS (SEE PLAN) E. CONDENSE DRAIN TO APPROVED PLUMBING FIXTURE F. LIGHT, SWITCH, OUTLET 2. MECHANICAL EQUIPMENTS: HEATING: SEE MECH. DWGS. COOLING: SEE MECH. DWGS. 3. PROVIDE A MINIMUM 30X30 INCH ACCESS; MAXIMUM OF 20 FEET FROM OPENING TO FURNACE, 24 INCH WIDE WALKWAY AND 30 INCH DEEP WORK PLATFORM; PROVIDE ELECTRIC LIGHT OUTLET ADJACENT TO FURNACE AND SWITCH BY THE OPENING. 4. HEATING EQUIPMENT THAT MAY GENERATE A GLOW, SPARK OR FLAME SHALL HAVE BURNERS OR PILOTS 18" ABOVE THE GARAGE FLOOR. . 5. DUCTS THROUGH ATTACHED GARAGE INTO DWELLING SHALL BE MINIMUM 26-GAUGE GALVANIZED STEEL. 6. EVERY DWELLING SHALL BE PROVIDED WITH HEATING FACILITIES CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF 68 DEGREES FARENHEIT AT A POINT 3' ABOVE THE FLOOR IN HABITABLE ROOMS. 2022 CBC SEC. 1204.1. 7. EVERY DWELLING UNIT SHALL BE PROVIDED WITH A WHOLE HOUSE FAN MEETING THE REQUIREMENTS OUTLINED IN THE CALIFORNIA ENERGY COMMISSION '2022 BUILDING ENERGY EFFICIENCY STANDARDS FOR RESIDENTIAL AND NON-RESIDENTIAL BUILDINGS' SUBCHAPTER 8, SECTION 150.1(c)12 SITE RELATED GENERAL NOTESQ. 1. ALL INDICATED BOUNDARY AND EXISTING SITE CONDITIONS IS BASED ON A SURVEY PREPARED BY THE CIVIL ENGINEER. 2. ALL UTILITY SERVICES SHALL BE INSTALLED UNDERGROUND. 3. FOR SITE PLANTING FEATURES AND IRRIGATION FACILITIES, SEE LANDSCAPE PLANS. 4. FOR SITE GRADING UTILITIES, ELEVATION AND DRAINAGE, SEE CIVIL PLANS. 5. BEFORE COMMENCEMENT OF WORK, CONTRACTOR TO CONTACT ALL GOVERNMENT AGENCIES AND UTILITY COMPANIES WHICH MAY HAVE SERVICES IN THE AREA. THE CONTRACTOR SHALL BE ASSURES THAT ALL UNDERGROUND SERVICES ARE IDENTIFIED PRIOR TO ANY SUBSURFACE EXCAVATION AND SHALL PROTECT ALL EXISTING UNDERGROUND SERVICES. 6. PRIOR TO CONSTRUCTION, CONTRACTOR TO COORDINATE WITH UTILITY COMPANIES AND AGENCIES ON WORK PERTAINING TO SERVICES SUCH AS CABLE TV, ELECTRICITY, GAS, WATER AND SEWER FROM SOURCE OF SERVICES TO BUILDING HOOK-UP. 7. OWNER SHALL FURNISH SERVICES OF GEOTECHNICAL ENGINEERS TO INCLUDE BUT NOT LIMITED TO SOILS BORING TEST. SOILS BEARING VALUE DETERMINATION, PERCOLATION TEST, EVALUATIONS OF HAZARDOUS MATERIALS, GROUND CORROSION AND RESISTIVITY TESTS INCLUDING NECESSARY OPERATIONS FOR ANTICIPATING SUBSOIL CONDITIONS WITH REPORTS AND RECOMMENDATIONS. 8. CONTACT CIVIL ENGINEER OF RECORD FOR SITE PREPARATION AND GRADING RECOMMENDATIONS. 9. ALL SURFACE WATER TO DRAIN AWAY FROM BUILDING AND DRIVEWAY TO ALLEY OR STREET OR PUBLIC STORM DRAIN SYSTEM. PLUMBING NOTES (2022 CPC)P. 1. COMBUSTION AIR FOR WATER HEATERS SHALL BE SUPPLIED PER 507.3; 507.4; 507.4.1 OF 2022 CPC. 2. ANCHOR OR STRAP WATER HEATER AT POINTS WITHIN THE UPPER ONE-THIRD (1/3) AND LOWER ONETHIRD (1/3) OF ITS VERTICAL DIMENSIONS. THE LOWER STRAP MUST BE NO CLOSER THAN 4" ABOVE THE CONTROLS. 2022 CPC SEC. 508.2. 3. FIBERGLASS TUB/SHOWER SHALL BE ICC APPROVED. 4. BACKWATER VALVE REQUIRED WHEN DRAINAGE PIPING HAS THE FLOOD LEVEL RIM LOCATED BELOW THE ELEVATION OF THE NEXT UPSTREAM MANHOLE COVERS. ALL FIXTURES ABOVE UPSTREAM MANHOLE COVER SHALL NOT DISCHARGE THROUGH THE BACKWATER VALVE. 5. PROVIDE A MIN. OF 3" DIAMETER SEWER/DRAIN LINE WITH 2% MIN. SLOPE. 6. USE 2X6 MIN. STUDS FOR PLUMBING WALLS. 7. SHOWER AND TUB-SHOWER COMBINATIONS SHALL BE PROVIDED WITH MIXING VALVES THAT ARE THE PRESSURE BALANCE TYPE OR TEMPERATURE LIMITING TYPE. 8. FIXTURES HAVING SLIP-JOINT CONNECTIONS SHALL HAVE A 12" X 12" MINIMUM ACCESS PANEL. 9. SPECIFY LOW FLOW TOILETS (1.6 GALLON/FLUSH), SHOWERHEADS (2.5 GPM) AND FAUCETS (2.5 GPM). 10. HOSE BIBBS SHALL BE FITTED WITH A NON-REMOVABLE BACKFLOW PREVENTION DEVICE. 11. PAD SUPPORTING COMPRESSOR/CONDENSER/WATER HEATER SHALL BE A MINIMUM OF 3" ABOVE GRADE. ELECTRICAL NOTES (2022 CEC)N.MECHANICAL NOTES (2022 CMC)O. Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update A0.5 2022 CALGREEN MAXIMUM INCREMENTAL REACTIVITY (MIR). THE MAXIMUM CHANGE IN WEIGHT OF OZONE FORMED BY ADDING A COMPOUND TO THE "BASE REACTIVE ORGANIC GAS (ROG) MIXTURE" PER WEIGHT OF COMPOUND ADDED, EXPRESSED TO HUNDREDTHS OF A GRAM (G O³/G ROC). NOTE: MIR VALUES FOR INDIVIDUAL COMPOUNDS AND HYDROCARBON SOLVENTS ARE SPECIFIED IN CCR, TITLE 17, SECTIONS 94700 AND 94701. MOISTURE CONTENT. THE WEIGHT OF THE WATER IN WOOD EXPRESSED IN PERCENTAGE OF THE WEIGHT OF THE OVEN-DRY WOOD. PRODUCT-WEIGHTED MIR (PWMIR). THE SUM OF ALL WEIGHTED-MIR FOR ALL INGREDIENTS IN A PRODUCT SUBJECT TO THIS ARTICLE. THE PWMIR IS THE TOTAL PRODUCT REACTIVITY EXPRESSED TO HUNDREDTHS OF A GRAM OF OZONE FORMED PER GRAM OF PRODUCT (EXCLUDING CONTAINER AND PACKAGING).NOTE: PWMIR IS CALCULATED ACCORDING TO EQUATIONS FOUND IN CCR, TITLE 17, SECTION 94521 (A). REACTIVE ORGANIC COMPOUND (ROC). ANY COMPOUND THAT HAS THE POTENTIAL, ONCE EMITTED, TO CONTRIBUTE TO OZONE FORMATION IN THE TROPOSPHERE. VOC. A VOLATILE ORGANIC COMPOUND (VOC) BROADLY DEFINED AS A CHEMICAL COMPOUND BASED ON CARBON CHAINS OR RINGS WITH VAPOR PRESSURES GREATER THAN 0.1 MILLIMETERS OF MERCURY AT ROOM TEMPERATURE. THESE COMPOUNDS TYPICALLY CONTAIN HYDROGEN AND MAY CONTAIN OXYGEN, NITROGEN AND OTHER ELEMENTS. SEE CCR TITLE 17, SECTION 94508(A). 4.503 FIREPLACES 4.503.1 GENERAL. ANY INSTALLED GAS FIREPLACE SHALL BE A DIRECT-VENT SEALED-COMBUSTION TYPE. ANY INSTALLED WOODSTOVE OR PELLET STOVE SHALL COMPLY WITH U.S. EPA NEW SOURCE PERFORMANCE STANDARDS (NSPS) EMISSION LIMITS AS APPLICABLE, AND SHALL HAVE A PERMANENT LABEL INDICATION THEY ARE CERTIFIED TO MEET THE EMISSION LIMTS. WOODSTOVES, PELLET STOVES AND FIREPLACES SHALL ALSO COMPLY WITH APPLICABLE LOCAL ORDINANCES. 4.504 POLLUTANT CONTROL 4.504.1 COVERING OF DUCT OPENINGS & PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION. AT THE TIME OF ROUGH INSTALLATION, DURING STORAGE ON THE CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF WATER, DUST OR DEBRIS WHICH MAY ENTER THE SYSTEM. 4.504.2 FINISH MATERIAL POLLUTANT CONTROL. FINISH MATERIALS SHALL COMPLY WITH THIS SECTION. 4.504.2.1 ADHESIVES, SEALANTS AND CAULKS. ADHESIVES, SEALANT AND CAULKS USED ON THE PROJECT SHALL MEET THE REQUIREMENTS OF THE FOLLOWING STANDARDS UNLESS MORE STRINGENT LOCAL OR REGIONAL AIR POLLUTION OR AIR QUALITY MANAGEMENT DISTRICT RULES APPLY: 1. ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS, SEALANT PRIMERS AND CAULKS SHALL COMPLY WITH LOCAL OR REGIONAL AIR POLLUTION CONTROL OR AIR QUALITY MANAGEMENT DISTRICT RULES WHERE APPLICABLE OR SCAQMD RULE 1168 VOC LIMITS, AS SHOWN IN TABLE 4.504.1 OR 4.504.2, AS APPLICABLE. SUCH PRODUCTS ALSO SHALL COMPLY WITH THE RULE 1168 PROHIBITION ON THE USE OF CERTAIN TOXIC COMPOUNDS (CHLOROFORM, ETHYLENE DICHLORIDE, METHYLENE CHLORIDE, PERCHLOROETHYLENE AND TRICLOROETHYLENE), EXCEPT FOR AEROSOL PRODUCTS, AS SPECIFIED IN SUBSECTION 2 BELOW. 2. AEROSOL ADHESIVES, AND SMALLER UNIT SIZES OF ADHESIVES, AND SEALANT OR CAULKING COMPOUNDS (IN UNITS OF PRODUCT, LESS PACKAGING, WHICH DO NOT WEIGH MORE THAN 1 POUND AND DO NOT CONSIST OF MORE THAN 16 FLUID OUNCES) SHALL COMPLY WITH STATEWIDE VOC STANDARDS AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS, OF CALIFORNIA CODE OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94507. 4.504.2.2 PAINTS AND COATINGS. ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH VOC LIMITS IN TABLE 1 OF THE ARB ARCHITECTURAL SUGGESTED CONTROL MEASURE, AS SHOWN IN TABLE 4.504.3, UNLESS MORE STRINGENT LOCAL LIMITS APPLY. THE VOC CONTENT LIMIT FOR COATINGS THAT DO NOT MEET THE DEFINITIONS FOR THE SPECIALTY COATINGS CATEGORIES LISTED IN TABLE 4.504.3 SHALL BE DETERMINED BY CLASSIFYING THE COATING AS A FLAT, NONFLAT OR NONFLAT-HIGH GLOSS COATING, BASED ON ITS GLOSS, AS DEFINED IN SUBSECTIONS 4.21, 4.36, AND 4.37 OF THE 2007 CALIFORNIA AIR RESOURCES BOARD, SUGGESTED CONTROL MEASURE, AND THE CORRESPONDING FLAT, NONFLAT OR NONFLAT-HIGH GLOSS VOC LIMIT IN TABLE 4.504.3 SHALL APPLY. 4.504.2.3 AEROSOL PAINTS AND COATINGS. AEROSOL PAINTS AND COATINGS SHALL MEET THE PRODUCT-WEIGHTED MIR LIMITS FOR ROC IN SECTION 94522(A)(2) AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS AND OZONE DEPLETING SUBSTANCES, IN SECTIONS 94522(E)(1) AND (F)(1) OF CALIFORNIA CODE OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94520; AND IN AREAS UNDER THE JURISDICTION OF THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT ADDITIONALLY COMPLY WITH THE PERCENT VOC BY WEIGHT OF PRODUCT LIMITS OF REGULATION 8, RULE 49. 4.504.2.4 VERIFICATION. VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AT THE REQUEST OF THE ENFORCING AGENCY. DOCUMENTATION MAY INCLUDE, BUT IS NOT LIMITED TO, THE FOLLOWING: 1. MANUFACTURER'S PRODUCT SPECIFICATION. 2. FIELD VERIFICATION OF ON-SITE PRODUCT CONTAINERS. 4.304 OUTDOOR WATER USE 4.304.1 IRRIGATION CONTROLLERS. AUTOMATIC IRRIGATION SYSTEM CONTROLLERS FOR LANDSCAPING PROVIDED BY THE BUILDER AND INSTALLED AT THE TIME OF FINAL INSPECTION SHALL COMPLY WITH THE FOLLOWING: 1. CONTROLLERS SHALL BE WEATHER- OR SOIL MOISTURE-BASED CONTROLLERS THAT AUTOMATICALLY ADJUST IRRIGATION IN RESPONSE TO CHANGES IN PLANTS' NEEDS AS WEATHER CONDITIONS CHANGE. 2. WEATHER-BASED CONTROLLERS WITHOUT INTEGRAL RAIN SENSORS OR COMMUNICATION SYSTEMS THAT ACCOUNT FOR LOCAL RAINFALL SHALL HAVE A SEPARATE WIRED OR WIRELESS RAIN SENSOR WHICH CONNECTS OR COMMUNICATES WITH THE CONTROLLER(S). SOIL MOISTURE-BASED CONTROLLERS ARE NOT REQUIRED TO HAVE RAIN SENSOR INPUT. NOTE: MORE INFORMATION REGARDING IRRIGATION CONTROLLER FUNCTION AND SPECIFICATIONS IS AVAILABLE FROM THE IRRIGATION ASSOCIATION. TABLE 4.504.1 - ADHESIVE VOC LIMIT1,2 (Less Water and Less Exempt Compounds in Grams per Liter) ARCHITECTURAL APPLICATIONS CURRENT VOC LIMIT INDOOR CARPET ADHESIVES 50 CARPET PAD ADHESIVES 50 OUTDOOR CARPET ADHESIVES 150 WOOD FLOORING ADHESIVES 100 RUBBER FLOOR ADHESIVES 60 SUBFLOOR ADHESIVES 50 CERAMIC TILE ADHESIVES 65 VCT & ASPHALT TILE ADHESIVES 50 DRYWALL & PANEL ADHESIVES 50 COVE BASE ADHESIVES 50 MULTIPURPOSE CONSTRUCTION ADHESIVE 70 STRUCTURAL GLAZING ADHESIVES 100 SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 OTHER ADHESIVES NOT LISTED 50 SPECIALTY APPLICATIONS PVC WELDING 510 CPVC WELDING 490 ABS WELDING 325 PLASTIC CEMENT WELDING 250 ADHESIVE PRIMER FOR PLASTIC 550 CONTACT ADHESIVE 80 SPECIAL PURPOSE CONTACT ADHESIVE 250 STRUCTURAL WOOD MEMBER ADHESIVE 140 TOP & TRIM ADHESIVE 250 SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 PLASTIC FOAMS 50 POROUS MATERIAL (EXCEPT WOOD)50 WOOD 30 FIBERGLASS 80 1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER, THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED. 2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. 4.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE 4.406.1 RODENT PROOFING. ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY OR A SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY. 4.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING 4.408.1 CONSTRUCTION WASTE MANAGEMENT. RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65 PERCENT OF THE NON-HAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH EITHER SECTION 4.408.2, 4.408.3 OR 4.408.4, OR MEET A MORE STRINGENT LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE. EXCEPTIONS: 1. EXCAVATED SOIL AND LAND-CLEARING DEBRIS. 2. ALTERNATE WASTE REDUCTION METHODS DEVELOPED BY WORKING WITH LOCAL AGENCIES IF DIVERSION OR RECYCLE FACILITIES CAPABLE OF COMPLIANCE WITH THIS ITEM DO NOT EXIST OR ARE NOT LOCATED REASONABLY CLOSE TO THE JOBSITE. 3. THE ENFORCING AGENCY MAY MAKE EXCEPTIONS TO THE REQUIREMENTS OF THIS SECTION WHEN ISOLATED JOBSITE ARE LOCATED IN AREAS BEYOND THE HAUL BOUNDARIES OF THE DIVERSION FACILITY. 4.408.2 CONSTRUCTION WASTE MANAGEMENT PLAN. SUBMIT A CONSTRUCTION WASTE MANAGEMENT PLAN IN CONFORMANCE WITH ITEMS 1 THROUGH 5. THE CONSTRUCTION WASTE MANAGEMENT PLAN SHALL BE UPDATED AS NECESSARY AND SHALL BE AVAILABLE DURING CONSTRUCTION FOR EXAMINATION BY THE ENFORCING AGENCY. 1. IDENTIFY THE CONSTRUCTION AND DEMOLITION WASTE MATERIALS TO BE DIVERTED FROM DISPOSAL BY RECYCLING, REUSE ON THE PROJECT OR SALVAGE FOR FUTURE USE OR SALE. 2. SPECIFY IF CONSTRUCTION AND DEMOLITION WASTE MATERIALS WILL BE SORTED ON-SITE (SOURCE SEPARATED) OR BULK MIXED (SINGLE STREAM). 3. IDENTIFY DIVERSION FACILITIES WHERE THE CONSTRUCTION AND DEMOLITION WASTE MATERIAL COLLECTED WILL BE TAKEN. 4. IDENTIFY CONSTRUCTION METHODS EMPLOYED TO REDUCE THE AMOUNT OF CONSTRUCTION AND DEMOLITION WASTE GENERATED. 5. SPECIFY THAT THE AMOUNT OF CONSTRUCTION AND DEMOLITION WASTE MATERIALS DIVERTED SHALL BE CALCULATED BY WEIGHT OR VOLUME, BUT NOT BY BOTH. 4.408.3 WASTE MANAGEMENT COMPANY. UTILIZE A WASTE MANAGEMENT COMPANY, APPROVED BY THE ENFORCING AGENCY, WHICH CAN PROVIDE VERIFIABLE DOCUMENTATION THAT THE PERCENTAGE OF CONSTRUCTION AND DEMOLITION WASTE MATERIAL DIVERTED FROM THE LANDFILL COMPLIES WITH SECTION 4.408.1. NOTE: THE OWNER OR CONTRACTOR MAY MAKE THE DETERMINATION IF THE CONSTRUCTION AND DEMOLITION WASTE MATERIALS WILL BE DIVERTED BY A WASTE MANAGEMENT COMPANY. 4.408.4 WASTE STREAM REDUCTION ALTERNATIVE [LR]. PROJECTS THAT GENERATE A TOTAL COMBINED WEIGHT OF CONSTRUCTION AND DEMOLITION WASTE DISPOSED OF IN LANDFILLS, WHICH DO NOT EXCEED 3.4 LBS./SQ.FT. OF THE BUILDING AREA SHALL MEET THE MINIMUM 65% CONSTRUCTION WASTE REDUCTION REQUIREMENT IN SECTION 4.408.1 4.408.4.1 WASTE STREAM REDUCTION ALTERNATIVE. PROJECTS THAT GENERATE A TOTAL COMBINED WEIGHT OF CONSTRUCTION AND DEMOLITION WASTE DISPOSED OF IN LANDFILLS, WHICH DO NOT EXCEED 2 LBS./SQ.FT. OF THE BUILDING AREA, SHALL MEET THE MINIMUM 65% CONSTRUCTION WASTE REDUCTION REQUIREMENT IN SECTION 4.408.1 4.408.5 DOCUMENTATION. DOCUMENTATION SHALL BE PROVIDED TO THE ENFORCING AGENCY WHICH DEMONSTRATES COMPLIANCE WITH SECTION 4.408.2, ITEMS 1 THROUGH 5, SECTION 4.408.3 OR SECTION 4.408.4.. NOTES: 1. SAMPLE FORMS FOUND IN "A GUIDE TO THE CALIFORNIA GREEN BUILDING STANDARDS CODE (RESIDENTIAL)" LOCATED AT WWW.HCD.CA.GOV/CALGREEN.HTML MAY BE USED TO ASSIST IN DOCUMENTING COMPLIANCE WITH THIS SECTION. 2. MIXED CONSTRUCTION AND DEMOLITION DEBRIS (C & D) PROCESSORS CAN BE LOCATED AT THE CALIFORNIA DEPARTMENT OF RESOURCES RECYCLING AND RECOVERY (CALRECYCLE). DIVISION 4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY 4.410 BUILDING MAINTENANCE AND OPERATION 4.410.1 OPERATION AND MAINTENANCE MANUAL. AT THE TIME OF FINAL INSPECTION, A MANUAL, COMPACT DISC, WEB-BASED REFERENCE OR OTHER MEDIA ACCEPTABLE TO THE ENFORCING AGENCY WHICH INCLUDES ALL OF THE FOLLOWING SHALL BE PLACED IN THE BUILDING: 1. DIRECTIONS TO THE OWNER OR OCCUPANT THAT THE MANUAL SHALL REMAIN WITH THE BUILDING THROUGHOUT THE LIFE CYCLE OF THE STRUCTURE. 2. OPERATION AND MAINTENANCE INSTRUCTIONS FOR THE FOLLOWING: A. EQUIPMENT AND APPLIANCES, INCLUDING WATER-SAVING DEVICES AND SYSTEMS, HVAC SYSTEMS, PHOTOVOLTAIC SYSTEMS, ELECTRIC VEHICLE CHARGERS, WATER-HEATING SYSTEMS AND OTHER MAJOR APPLIANCES AND EQUIPMENT. B. ROOF AND YARD DRAINAGE, INCLUDING GUTTERS AND DOWNSPOUTS. C. SPACE CONDITIONING SYSTEMS, INCLUDING CONDENSERS AND AIR FILTERS. D. LANDSCAPE IRRIGATION SYSTEMS. E. WATER REUSE SYSTEMS. 3. INFORMATION FROM LOCAL UTILITY, WATER AND WASTE RECOVERY PROVIDERS ON METHODS TO FURTHER REDUCE RESOURCE CONSUMPTION, INCLUDING RECYCLE PROGRAMS AND LOCATIONS. 4. PUBLIC TRANSPORTATION AND/OR CARPOOL OPTIONS AVAILABLE IN THE AREA. 5. EDUCATIONAL MATERIAL ON THE POSITIVE IMPACTS OF AN INTERIOR RELATIVE HUMIDITY BETWEEN 30-60 PERCENT AND WHAT METHODS AN OCCUPANT MAY USE TO MAINTAIN THE RELATIVE HUMIDITY LEVEL IN THAT RANGE. 6. INFORMATION ABOUT WATER-CONSERVING LANDSCAPE AND IRRIGATION DESIGN AND CONTROLLERS WHICH CONSERVE WATER. 7. INSTRUCTIONS FOR MAINTAINING GUTTERS AND DOWNSPOUTS AND THE IMPORTANCE OF DIVERTING WATER AT LEAST 5 FEET AWAY FROM THE FOUNDATION. 8. INFORMATION ON REQUIRED ROUTINE MAINTENANCE MEASURES, INCLUDING, BUT NOT LIMITED TO, CAULKING, PAINTING, GRADING AROUND THE BUILDING, ETC. 9. INFORMATION ABOUT STATE SOLAR ENERGY AND INCENTIVE PROGRAMS AVAILABLE. 10. A COPY OF ALL SPECIAL INSPECTIONS VERIFICATIONS REQUIRED BY THE ENFORCING AGENCY OR THIS [CALIFORNIA GREEN BUILDING STANDARDS] CODE. 4.410.2 RECYCLING BY OCCUPANTS. WHERE 5 OR MORE MULTIFAMILY DWELLING UNITS ARE CONSTRUCTED ON A BUILDING SITE, PROVIDE READILY ACCESSIBLE AREA(S) THAT SERVES ALL BUILDINGS ON THE SITE AND IS IDENTIFIED FOR THE DEPOSITING, STORAGE AND COLLECTION OF NON-HAZARADOUS MATERIALS FOR RECYCLING, INCLUDING (AT A MINIMUM) PAPER, CORRUGATED CARDBOARD, GLASS, PLASTICS, ORGANIC WASTER, AND METALS, OR MEET A LAWFULLY ENACTED LOCAL RECYCLING ORDINANCE, IF MORE RESTRICTIVE. DIVISION 4.5 ENVIRONMENTAL QUALITY SECTION 4.501 GENERAL 4.501.1 SCOPE THE PROVISIONS OF THIS CHAPTER SHALL OUTLINE MEANS OF REDUCING THE QUALITY OF AIR CONTAMINANTS THAT ARE ODOROUS, IRRITATING AND/OR HARMFUL TO THE COMFORT AND WELL BEING OF A BUILDING'S INSTALLERS, OCCUPANTS AND NEIGHBORS. SECTION 4.502 DEFINITIONS 5.102.1 DEFINITIONS THE FOLLOWING TERMS ARE DEFINED IN CHAPTER 2 (AND ARE INCLUDED HERE FOR REFERENCE) AGRIFIBER PRODUCTS. AGRIFIBER PRODUCTS INCLUDE WHEATBOARD, STRAWBOARD, PANEL SUBSTRATES AND DOOR CORES, NOT INCLUDING FURNITURE, FIXTURES AND EQUIPMENT (FF&E) NOT CONSIDERED BASE BUILDING ELEMENTS. COMPOSITE WOOD PRODUCTS. COMPOSITE WOOD PRODUCTS INCLUDE HARDWOOD PLYWOOD, PARTICLEBOARD AND MEDIUM DENSITY FIBERBOARD. "COMPOSITE WOOD PRODUCTS" DOES NOT INCLUDE HARDBOARD, STRUCTURAL PLYWOOD, STRUCTURAL PANELS, STRUCTURAL COMPOSITE LUMBER, ORIENTED STRAND BOARD, GLUED LAMINATED TIMBER, PREFABRICATED WOOD I-JOISTS OR FINGER-JOINTED LUMBER, ALL AS SPECIFIED IN CALIFORNIA CODE OF REGULATIONS (CCR), TITLE 17, SECTION 93120.1. DIRECT-VENT APPLIANCE. A FUEL-BURNING APPLIANCE WITH A SEALED COMBUSTION SYSTEM THAT DRAWS ALL AIR FOR COMBUSTION FROM THE OUTSIDE ATMOSPHERE AND DISCHARGES ALL FLUE GASES TO THE OUTSIDE ATMOSPHERE. 4.106.4.2.2 ELECTRIC VEHICLE CHARGING SPACE (EV SPACE) DIMENSIONS. THE EV SPACE SHALL BEDESIGNED TO COMPLY WITH THE FOLLOWING: 1. THE MINIMUM LENGTH OF EACH EV SPACE SHALL BE 18 FEET (5486 MM). 2. THE MINIMUM WIDTH OF EACH EV SPACE SHALL BE 9 FEET (2743 MM). 3. ONE IN EVERY 25 EV SPACES, BUT NOT LESS THAN ONE EV SPACE, SHALL HAVE AN 8-FOOT (2438 MM) WIDE MINIMUM AISLE. A 5-FOOT (1524 MM) WIDE MINIMUM AISLE SHALL BE PERMITTED PROVIDED THE MINIMUM WIDTH OF THE EV SPACE IS 12 FEET (3658 MM). A. SURFACE SLOPE FOR THIS EV SPACE AND THE AISLE SHALL NOT EXCEED 1 UNIT VERTICAL IN 48 UNITS HORIZONTAL (2.083 PERCENT SLOPE) IN ANY DIRECTION. 4.106.4.2.3 SINGLE EV SPACE REQUIRED. INSTALL A LISTED RACEWAY CAPABLE OF ACCOMMODATING A 208/240-VOLT DEDICATED BRANCH CIRCUIT. THE RACEWAY SHALL NOT BE LESS THAN TRADE SIZE 1 (NOMINAL 1-INCH INSIDE DIAMETER). THE RACEWAY SHALL ORIGINATE AT THE MAIN SERVICE OR SUBPANEL AND SHALL TERMINATE INTO A LISTED CABINET, BOX OR ENCLOSURE IN CLOSE PROXIMITY TO THE PROPOSED LOCATION OF THE EV SPACES. CONSTRUCTION DOCUMENTS SHALL IDENTIFY THE RACEWAY TERMINATION POINT. THE SERVICE PANEL AND/OR SUBPANEL SHALL PROVIDE CAPACITY TO INSTALL A 40-AMPERE MINIMUM DEDICATED BRANCH CIRCUIT AND SPACE(S) RESERVED TO PERMIT INSTALLATION OF A BRANCH CIRCUIT OVERCURRENT PROTECTIVE DEVICE. 4.106.4.2.4 MULTIPLE EV SPACES REQUIRED. CONSTRUCTION DOCUMENTS SHALL INDICATE THE RACEWAY TERMINATION POINT AND PROPOSED LOCATION OF FUTURE EV SPACES AND EV CHARGERS. CONSTRUCTION DOCUMENTS SHALL ALSO PROVIDE INFORMATION ON AMPERAGE OF FUTURE EVSE, RACEWAY METHOD(S), WIRING SCHEMATICS AND ELECTRICAL LOAD CALCULATIONS TO VERIFY THAT THE ELECTRICAL PANEL SERVICE CAPACITY AND ELECTRICAL SYSTEM, INCLUDING ANY ON-SITE DISTRIBUTION TRANSFORMER(S), HAVE SUFFICIENT CAPACITY TO SIMULTANEOUSLY CHARGE ALL EVS AT ALL REQUIRED EV SPACES AT THE FULL RATED AMPERAGE OF THE EVSE. PLAN DESIGN SHALL BE BASED UPON A 40-AMPERE MINIMUM BRANCH CIRCUIT. RACEWAYS AND RELATED COMPONENTS THAT ARE PLANNED TO BE INSTALLED UNDERGROUND, ENCLOSED, INACCESSIBLE OR IN CONCEALED AREAS AND SPACES SHALL BE INSTALLED AT THE TIME OF ORIGINAL CONSTRUCTION. 4.106.4.2.5 INDENTIFICATION. THE SERVICE PANEL OR SUBPANEL CIRCUIT DIRECTORY SHALL IDENTIFY THE OVERCURRENT PROTECTIVE DEVICE SPACE(S) RESERVED FOR FUTURE EV CHARGING PURPOSES AS "EV CAPABLE" IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE. NOTES: 1. THE CALIFORNIA DEPARTMENT OF TRANSPORTATION ADOPTS AND PUBLISHES THE "CALIFORNA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (CALIFORNIA MUTCD)" TO PROVIDE UNIFORM STANDARDS AND SPECIFICATIONS FOR ALL OFFICIAL TRAFFIC CONTROL DEVICES IN CALIFORNIA. ZERO EMISSION VEHICLE SIGNS AND PAVEMENT MARKINGS CAN BE FOUND IN THE NEW POLICIES & DIRECTIVES NUMBER 13-01. WEBSITE: WWW.DOT.CA.GOV/TRAFFICOPS/POLICY/13-01.PDF 2. SEE VEHICLE CODE SECTION 22511 FOR EV CHARGING SPACE SIGNAGE IN OFF-STREET PARKING FACILITIES AND FOR USE OF EV CHARGING SPACES. 3. THE GOVERNOR'S OFFICE OF PLANNING AND RESEARCH (OPR) PUBLISHED A "ZERO-EMISSION VEHICLE COMMUNITY READINESS GUIDEBOOK" WHICH PROVIDES HELPFUL INFORMATION FOR LOCAL GOVERNMENTS, RESIDENTS AND BUSINESSES. WEBSITE: HTTP://OPR.CA.GOV/DOCS/ZEV_GUIDEBOOK.PDF. 4.201 GENERAL 4.201.1 SCOPE. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory standards. DIVISION 4.2 ENERGY EFFICIENCY DIVISION 4.3 WATER EFFICIENCY AND CONSERVATION 4.303 INDOOR WATER USE 4.303.1 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. PLUMBING FIXTURES (WATER CLOSETS AND URINALS) AND FITTINGS (FAUCETS AND SHOWERHEADS) SHALL COMPLY WITH THE FOLLOWING: 4.303.1.1 WATER CLOSETS. THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT EXCEED 1.28 GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE PERFORMANCE CRITERIA OF THE U.S. EPA WATERSENSE SPECIFICATION FOR TANK-TYPE TOILETS. NOTE: THE EFFECTIVE FLUSH VOLUME OF DUAL FLUSH TOILETS IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO REDUCED FLUSHES AND ONE FULL FLUSH. 4.303.1.2 URINALS. THE EFFECTIVE FLUSH VOLUME OF WALL MOUNTED URINALS SHALL NOT EXCEED 0.125 GALLONS PER FLUSH. THE EFFECTIVE FLUSH VOLUME OF ALL OTHER URINALS SHALL NOT EXCEED 0.5 GALLONS PER FLUSH. 4.303.1.3 SHOWERHEADS. 4.303.1.3.1 SINGLE SHOWERHEAD. SHOWERHEADS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 2.0 GALLONS PER MINUTE AT 80 PSI. SHOWERHEADS SHALL BE CERTIFIED TO THE PERFORMANCE CRITERIA OF THE U.S. EPA WATERSENSE SPECIFICATION FOR SHOWERHEADS. 4.303.1.3.2 MULTIPLE SHOWERHEADS SERVING ONE SHOWER. WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL THE SHOWERHEADS AND/OR OTHER SHOWER OUTLETS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT 80 PSI, OR THE SHOWER SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWER OUTLET TO BE IN OPERATION AT A TIME. TABLE - MAXIMUM FIXTURE WATER USE FIXTURE TYPE FLOW RATE SHOWER HEADS (RESIDENTIAL)1.8 GMP @ 80 PSI LAVATORY FAUCETS (RESIDENTIAL)MAX. 1.2 GPM @ 60 PSI MIN. 0.8 GPM @ 20 PSI LAVATORY FAUCETS IN COMMON & PUBLIC USE AREAS 0.5 GPM @ 60 PSI KITCHEN FAUCETS 1.8 GPM @ 60 PSI METERING FAUCETS 0.25 GAL/CYCLE WATER CLOSET 1.28 GAL/FLUSH URINALS 0.125 GAL/FLUSH NOTE: THIS TABLE COMPILES THE DATA IN SECTION 4.303.1, AND IS INCLUDED AS A CONVENIENCE FOR THE USER. NOTE: A HAND-HELD SHOWER SHALL BE CONSIDERED A SHOWERHEAD. 4.303.1.4 FAUCETS. 4.303.1.4.1 RESIDENTIAL LAVATORY FAUCETS. THE MAXIMUM FLOW RATE OF RESIDENTIAL LAVATORY FAUCETS SHALL NOT EXCEED 1.2 GALLONS PER MINUTE AT 60 PSI. THE MINIMUM FLOW RATE OF RESIDENTIAL LAVATORY FAUCETS SHALL NOT BE LESS THAN 0.8 GALLONS PER MINUTE AT 20 PSI. 4.303.1.4.2 LAVATORY FAUCETS IN COMMON AND PUBLIC USE AREAS. THE MAXIMUM FLOW RATE OF LAVATORY FAUCETS INSTALLED IN COMMON AND PUBLIC USE AREAS (OUTSIDE OF DWELLINGS OR SLEEPING UNITS) IN RESIDENTIAL BUILDINGS SHALL NOT EXCEED 0.5 GALLONS PER MINUTE AT 60 PSI. 4.303.1.4.3 METERING FAUCETS. METERING FAUCETS WHEN INSTALLED IN RESIDENTIAL BUILDINGS SHALL NOT DELIVER MORE THAN 0.25 GALLONS PER CYCLE. 4.303.1.4.4 KITCHEN FAUCETS. THE MAXIMUM FLOW RATE OF KITCHEN FAUCETS SHALL NOT EXCEED 1.8 GALLONS PER MINUTE AT 60 PSI. KITCHEN FAUCETS MAY TEMPORARILY INCREASE THE FLOW ABOVE THE MAXIMUM RATE, BUT NOT TO EXCEED 2.2 GALLONS PER MINUTE AT 60 PSI, AND MUST DEFAULT TO A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT 60 PSI. NOTE: WHERE COMPLYING FAUCETS ARE UNAVAILABLE, AERATORS OR OTHER MEANS MAY BE USED TO ACHIEVE REDUCTION. 4.303.2 STANDARDS FOR PLUMBING FIXTURES AND FITTINGS. PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA PLUMBING CODE, AND SHALL MEET THE APPLICABLE STANDARDS REFERENCED IN TABLE 1701.1 OF THE CALIFORNIA PLUMBING CODE. CHAPTER 3 GREEN BUILDING SECTION 301 GENERAL 301.1 SCOPE. BUILDINGS SHALL BE DESIGNED TO INCLUDE THE GREEN BUILDING MEASURES SPECIFIED AS MANDATORY IN THE APPLICATION CHECKLISTS CONTAINED IN THIS CODE. VOLUNTARY GREEN BUILDING MEASURES ARE ALSO INCLUDED IN THE APPLICATION CHECKLISTS AND MAY BE INCLUDED IN THE DESIGN AND CONSTRUCTION OF STRUCTURES COVERED BY THIS CODE, BUT ARE NOT REQUIRED UNLESS ADOPTED BY A CITY, COUNTY, OR CITY AND COUNTY AS SPECIFIED IN SECTION 101.7. 301.1.1 ADDITIONS AND ALTERATIONS. [HCD] THE MANDATORY PROVISIONS OF CHAPTER 4 SHALL BE APPLIED TO ADDITIONS OR ALTERATIONS OF EXISTING RESIDENTIAL BUILDINGS WHERE THE ADDITION OR ALTERATION INCREASES THE BUILDING'S CONDITIONED AREA, VOLUME, OR SIZE. THE REQUIREMENTS SHALL APPLY ONLY TO AND/OR WITHIN THE SPECIFIC AREA OF THE ADDITION OR ALTERATION. NOTE: ON AND AFTER JANUARY 1, 2014, RESIDENTIAL BUILDINGS UNDERGOING PERMITTED ALTERATIONS, ADDITIONS, OR IMPROVEMENTS SHALL REPLACE NONCOMPLIANT PLUMBING FIXTURES WITH WATER-CONSERVING PLUMBING FIXTURES. PLUMBING FIXTURE REPLACEMENT IS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF FINAL COMPLETION, CERTIFICATE OF OCCUPANCY OR FINAL PERMIT APPROVAL BY THE LOCAL BUILDING DEPARTMENT. SEE CIVIL CODE SECTION 1101.1, ET SEQ., FOR THE DEFINITION OF A NONCOMPLIANT PLUMBING FIXTURE, TYPES OF RESIDENTIAL BUILDINGS AFFECTED AND OTHER IMPORTANT ENACTMENT DATES. 301.2 LOW-RISE AND HIGH-RISE RESIDENTIAL BUILDINGS. [HCD] THE PROVISIONS OF INDIVIDUALSECTIONS OF CALGREEN MAY APPLY TO EITHER LOW-RISE RESIDENTIAL BUILDINGS HIGH-RISE RESIDENTIAL BUILDINGS, OR BOTH. INDIVIDUAL SECTIONS WILL BE DESIGNATED BY BANNERS TO INDICATE WHERE THE SECTION APPLIES SPECIFICALLY TO LOW-RISE ONLY (LR) OR HIGH-RISE ONLY (HR). WHEN THE SECTION APPLIES TO BOTH LOW-RISE AND HIGH-RISE BUILDINGS, NO BANNER WILL BE USED. SECTION 302 MIXED OCCUPANCY BUILDINGS 302.1 MIXED OCCUPANCY BUILDINGS. IN MIXED OCCUPANCY BUILDINGS, EACH PORTION OF A BUILDING SHALL COMPLY WITH THE SPECIFIC GREEN BUILDING MEASURES APPLICABLE TO EACH SPECIFIC OCCUPANCY.CHAPTER 4 RESIDENTIAL MANDATORY MEASURES DIVISION 4.1 PLANNING AND DESIGN ABBREVIATION DEFINITIONS: HCD DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT BSC CALIFORNIA BUILDING STANDARDS COMMISSION DSA-SS DIVISION OF THE STATE ARCHITECT, STRUCTURAL SAFETY OSHPD OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT LR LOW RISE HR HIGH RISE AA ADDITIONS AND ALTERATIONS N NEW SECTION 4.102 DEFINITIONS 4.102.1 DEFINITIONS THE FOLLOWING TERMS ARE DEFINED IN CHAPTER 2 (AND ARE INCLUDED HERE FOR REFERENCE) FRENCH DRAIN. A TRENCH, HOLE OR OTHER DEPRESSED AREA LOOSELY FILLED WITH ROCK, GRAVEL, FRAGMENTS OF BRICK OR SIMILAR PERVIOUS MATERIAL USED TO COLLECT OR CHANNEL DRAINAGE OR RUNOFF WATER. WATTLES. WATTLES ARE USED TO REDUCE SEDIMENT IN RUNOFF. WATTLES ARE OFTEN CONSTRUCTED OF NATURAL PLANT MATERIALS SUCH AS HAY, STRAW OR SIMILAR MATERIAL SHAPED IN THE FORM OF TUBES AND PLACED ON A DOWNFLOW SLOPE. WATTLES ARE ALSO USED FOR PERIMETER AND INLET CONTROLS. 4.106 SITE DEVELOPMENT 4.106.1 GENERAL. PRESERVATION AND USE OF AVAILABLE NATURAL RESOURCES SHALL BE ACCOMPLISHED THROUGH EVALUATION AND CAREFUL PLANNING TO MINIMIZE NEGATIVE EFFECTS ON THE SITE AND ADJACENT AREAS. PRESERVATION OF SLOPES, MANAGEMENT OF STORM WATER DRAINAGE AND EROSION CONTROLS SHALL COMPLY WITH THIS SECTION. 4.106.2 STORM WATER DRAINAGE AND RETENTION DURING CONSTRUCTION. PROJECTS WHICH DISTURB LESS THAN ONE ACRE OF SOIL AND ARE NOT PART OF A LARGER COMMON PLAN OF DEVELOPMENT WHICH IN TOTAL DISTURBS ONE ACRE OR MORE, SHALL MANAGE STORM WATER DRAINAGE DURING CONSTRUCTION. IN ORDER TO MANAGE STORM WATER DRAINAGE DURING CONSTRUCTION, ONE OR MORE OF THE FOLLOWING MEASURES SHALL BE IMPLEMENTED TO PREVENT FLOODING OF ADJACENT PROPERTY, PREVENT EROSION AND RETAIN SOIL RUNOFF ON THE SITE. 1. RETENTION BASINS OF SUFFICIENT SIZE SHALL BE UTILIZED TO RETAIN STORM WATER ON THE SITE. 2. WHERE STORM WATER IS CONVEYED TO A PUBLIC DRAINAGE SYSTEM, COLLECTION POINT, GUTTER OR SIMILAR DISPOSAL METHOD, WATER SHALL BE FILTERED BY USE OF A BARRIER SYSTEM, WATTLE OR OTHER METHOD APPROVED BY THE ENFORCING AGENCY. 3. COMPLIANCE WITH A LAWFULLY ENACTED STORM WATER MANAGEMENT ORDINANCE. 4.106.3 GRADING AND PAVING. CONSTRUCTION PLANS SHALL INDICATE HOW THE SITE GRADING OR DRAINAGE SYSTEM WILL MANAGE ALL SURFACE WATER FLOWS TO KEEP WATER FROM ENTERING BUILDINGS. EXAMPLES OF METHODS TO MANAGE SURFACE WATER INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: 1. SWALES 2. WATER COLLECTION AND DISPOSAL SYSTEMS 3. FRENCH DRAINS 4. WATER RETENTION GARDENS 5. OTHER WATER MEASURES WHICH KEEP SURFACE WATER AWAY FROM BUILDINGS AND AID IN GROUNDWATER RECHARGE. EXCEPTION: ADDITIONS AND ALTERATIONS NOT ALTERING THE DRAINAGE PATH. 4.106.4 ELECTRIC VEHICLE (EV) CHARGING FOR NEW CONSTRUCTION. NEW CONSTRUCTION SHALL COMPLY WITH SECTIONS 4.106.4.1 AND 4.106.4.2 TO FACILITATE FUTURE INSTALLATION AND USE OF EV CHARGERS. ELECTRIC VEHICLE SUPPLY EQUIPMENT (EVSE) SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE, ARTICLE 625. EXCEPTIONS: ON A CASE-BY-CASE BASIS, WHERE THE LOCAL ENFORCING AGENCY HAS DETERMINED EV CHARGING AND INFRASTRUCTURE ARE NOT FEASIBLE BASED UPON ONE OR MORE OF THE FOLLOWING CONDITIONS: 1. WHERE THERE IS NO COMMERCIAL POWER SUPPLY. 2. WHERE THERE IS EVIDENCE SUBSTANTIATING THAT MEETING THE REQUIREMENTS WILL ALTER THE LOCAL UTILITY INFRASTRUCTURE DESIGN REQUIREMENTS ON THE UTILITY SIDE OF THE METER SO AS TO INCREASE THE UTILITY SIDE COST TO THE HOMEOWNER OR DEVELOPER BY MORE THAN $400.00 PER UNIT. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE-RESIDENTIAL MANDATORY MEASURES 4.106.4.1 NEW ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES WITH ATTACHED PRIVATE GARAGES. FOR EACH DWELLING UNIT, INSTALL A LISTED RACEWAY TO ACCOMMODATE A DEDICATED 208/240-VOLT BRANCH CIRCUIT. THE RACEWAY SHALL NOT BE LESS THAN TRADE SIZE 1 (NOMINAL 1-INCH INSIDE DIAMETER). THE RACEWAY SHALL ORIGINATE AT THE MAIN SERVICE OR SUBPANEL AND SHALL TERMINATE INTO A LISTED CABINET, BOX OR OTHER ENCLOSURE IN CLOSE PROXIMITY TO THE PROPOSED LOCATION OF AN EV CHARGER. RACEWAYS ARE REQUIRED TO BE CONTINUOUS AT ENCLOSED, INACCESSIBLE OR CONCEALED AREAS AND SPACES. THE SERVICE PANEL AND/OR SUBPANEL SHALL PROVIDE CAPACITY TO INSTALL A 40-AMPERE MINIMUM DEDICATED BRANCH CIRCUIT AND SPACE(S) RESERVED TO PERMIT INSTALLATION OF A BRANCH CIRCUIT OVERCURRENT PROTECTIVE DEVICE. 4.106.4.1.1 IDENTIFICATION. THE SERVICE PANEL OR SUBPANEL CIRCUIT DIRECTORY SHALL IDENTIFY THE OVERCURRENT PROTECTIVE DEVICE SPACE(S) RESERVED FOR FUTURE EV CHARGING AS "EV CAPABLE". THE RACEWAY TERMINATION LOCATION SHALL BE PERMANENTLY AND VISIBLY MARKED AS "EV CAPABLE". 4.106.4.2 NEW MULTIFAMILY DWELLINGS. WHERE 17 OR MORE MULTIFAMILY DWELLING UNITS ARE CONSTRUCTED ON A BUILDING SITE, 3 PERCENT OF THE TOTAL NUMBER OF PARKING SPACES PROVIDED FOR ALL TYPES OF PARKING FACILITIES, BUT IN NO CASE LESS THAN ONE, SHALL BE ELECTRIC VEHICLE CHARGING STATIONS (EV SPACES) CAPABLE OF SUPPORTING FUTURE EVSE. CALCULATIONS FOR THE NUMBER OF EV SPACES SHALL BE ROUNDED UP TO THE NEAREST WHOLE NUMBER. NOTE:CONSTRUCTION DOCUMENTS ARE INTENDED TO DEMONSTRATE THE PROJECT'S CAPABILITY AND CAPACITY FOR FACILITATING FUTURE EV CHARGING. THERE IS NO REQUIREMENT FOR EV SPACES TO BE CONSTRUCTED OR AVAILABLE UNTIL EV CHARGERS ARE INSTALLED FOR USE. 4.106.4.2.1 ELECTRIC VEHICLE CHARGING SPACE (EV SPACE) LOCATIONS. CONSTRUCTION DOCUMENTS SHALL INDICATE THE LOCATION OF PROPOSED EV SPACES. AT LEAST ONE EV SPACE SHALL BE LOCATED IN COMMON USE AREAS AND AVAILABLE FOR USE BY ALL RESIDENTS. WHEN EV CHARGERS ARE INSTALLED, EV SPACES REQUIRED BY SECTION 4.106.2.2, ITEM 3, SHALL COMPLY WITH AT LEAST ONE OF THE FOLLOWING OPTIONS: 1.THE EV SPACE SHALL BE LOCATED ADJACENT TO AN ACCESSIBLE PARKING SPACE MEETING THE REQUIREMENTS OF THE CALIFORNIA BUILDING CODE, CHAPTER 11A, TO ALLOW USE OF THE EV CHARGER FROM THE ACCESSIBLE PARKING SPACE. 2.THE EV SPACE SHALL BE LOCATED ON AN ACCESSIBLE ROUTE, AS DEFINED IN THE CALIFORNIA BUILDING CODE, CHAPTER 2, TO THE BUILDING. 1 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update A0.6 2022 CALGREEN 4.504.3 CARPET SYSTEMS. ALL CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE TESTING AND PRODUCT REQUIREMENTS OF AT LEAST ONE OF THE FOLLOWING: 1. CARPET AND RUG INSTITUTE'S GREEN LABEL PLUS PROGRAM. 2. CALIFORNIA DEPARTMENT OF PUBLIC HEALTH, "STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS" VERSION 1.1, FEBRUARY 2010 (ALSO KNOWN AS SPECIFICATION 01350). 3. NSF/ANSI 140 AT THE GOLD LEVEL. 4. SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGETM GOLD. 4.504.3.1 CARPET CUSHION. ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF THE CARPET AND RUG INSTITUTE'S GREEN LABEL PROGRAM. 4.504.3.2 CARPET ADHESIVE. ALL CARPET ADHESIVE SHALL MEET THE REQUIREMENTS OF TABLE 4.504.1. 4.504.4 RESILIENT FLOORING SYSTEMS. WHERE RESILIENT FLOORING IS INSTALLED , AT LEAST 80% OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH ONE OR MORE OF THE FOLLOWING: 1.PRODUCTS COMPLIANT WITH THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH, "STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS," VERSION 1.1, FEBRUARY 2010 (ALSO KNOWN AS SPECIFICATION 01350), CERTIFIED AS A CHPS LOW-EMITTING MATERIAL IN THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CHPS) HIGH PERFORMANCE PRODUCTS DATABASE. 2.PRODUCTS CERTIFIED UNDER UL GREENGUARD GOLD (FORMERLY THE GREENGUARD CHILDREN & SCHOOLS PROGRAM). 3.CERTIFICATION UNDER THE RESILIENT FLOOR COVERING INSTITUTE (RFCI) FLOORSCORE PROGRAM. 4.MEET THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH, "STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS", VERSION 1.1, FEBRUARY 2010 (ALSO KNOWN AS SPECIFICATION 01350). 4.504.5 COMPOSITE WOOD PRODUCTS. HARDWOOD PLYWOOD, PARTICLEBOARD AND MEDIUM DENSITY FIBERBOARD COMPOSITE WOOD PRODUCTS USED ON THE INTERIOR OR EXTERIOR OF THE BUILDINGS SHALL MEET THE REQUIREMENTS FOR FORMALDEHYDE AS SPECIFIED IN ARB'S AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD (17 CCR 93120 ET SEQ.), BY OR BEFORE THE DATES SPECIFIED IN THOSE SECTIONS, AS SHOWN IN TABLE 4.504.5 4.504.5.1 DOCUMENTATION. VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AS REQUESTED BY THE ENFORCING AGENCY. DOCUMENTATION SHALL INCLUDE AT LEAST ONE OF THE FOLLOWING: 1. PRODUCT CERTIFICATIONS AND SPECIFICATIONS. 2. CHAIN OF CUSTODY CERTIFICATIONS. 3. PRODUCT LABELED AND INVOICED AS MEETING THE COMPOSITE WOOD PRODUCTS REGULATION (SEE CCR, TITLE 17, SECTION 93120, ET SEQ.). 4. EXTERIOR GRADE PRODUCTS MARKED AS MEETING THE PS-1 OR PS-2 STANDARDS OF THE ENGINEERED WOOD ASSOCIATION, THE AUSTRALIAN AS/NZS 2269, EUROPEAN 636 3S STANDARDS, AND CANADIAN CSA 0121, CSA 0151, CSA 0153 AND CSA 0325 STANDARDS. 5. OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY. 4.505 INTERIOR MOISTURE CONTROL 4.505.1 GENERAL. BUILDINGS SHALL MEET OR EXCEED THE PROVISIONS OF THE CALIFORNIA BUILDING STANDARDS CODE. 4.505.2 CONCRETE SLAB FOUNDATIONS. CONCRETE SLAB FOUNDATIONS REQUIRED TO HAVE A VAPOR RETARDER BY CALIFORNIA BUILDING CODE, CHAPTER 19, OR CONCRETE SLAB-ON-GROUND FLOORS REQUIRED TO HAVE A VAPOR RETARDER BY THE CALIFORNIA RESIDENTIAL CODE, CHAPTER 5, SHALL ALSO COMPLY WITH THIS SECTION. 4.505.2.1 CAPILLARY BREAK. A CAPILLARY BREAK SHALL BE INSTALLED IN COMPLIANCE WITH AT LEAST ONE OF THE FOLLOWING: 1. A 4-INCH (101.6 MM) THICK BASE OF 1/2 INCH (12.7MM) OR LARGER CLEAN AGGREGATE SHALL BE PROVIDED WITH A VAPOR BARRIER IN DIRECT CONTACT WITH CONCRETE AND A CONCRETE MIX DESIGN, WHICH WILL ADDRESS BLEEDING, SHRINKAGE, AND CURLING, SHALL BE USED. FOR ADDITIONAL INFORMATION, SEE AMERICAN CONCRETE INSTITUTE, ACI 302.2R-06. 2. OTHER EQUIVALENT METHODS APPROVED BY THE ENFORCING AGENCY. 3. A SLAB DESIGN SPECIFIED BY A LICENSED DESIGN PROFESSIONAL. 4.505.3 MOISTURE CONTENT OF BUILDING MATERIALS. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE SHALL NOT BE INSTALLED. WALL AND FLOOR FRAMING SHALL NOT BE ENCLOSED WHEN THE FRAMING MEMBERS EXCEED 19 PERCENT MOISTURE CONTENT. MOISTURE CONTENT SHALL BE VERIFIED IN COMPLIANCE WITH THE FOLLOWING: 1. MOISTURE CONTENT SHALL BE DETERMINED WITH EITHER A PROBE-TYPE OR CONTACT-TYPE MOISTURE METER.EQUIVALENT MOISTURE VERIFICATION METHODS MAY BE APPROVED BY THE ENFORCING AGENCY AND SHALL SATISFY REQUIREMENTS FOUND IN SECTION 101.8 OF THIS CODE. 2. MOISTURE READINGS SHALL BE TAKEN AT A POINT 2 FEET (610 MM) TO 4 FEET (1219 MM) FROM THE GRADE STAMPED END OF EACH PIECE VERIFIED. 3. AT LEAST THREE RANDOM MOISTURE READINGS SHALL BE PERFORMED ON WALL AND FLOOR FRAMING WITH DOCUMENTATION ACCEPTABLE TO THE ENFORCING AGENCY PROVIDED AT THE TIME OF APPROVAL TO ENCLOSE THE WALL AND FLOOR FRAMING. INSULATION PRODUCTS WHICH ARE VISIBLY WET OR HAVE A HIGH MOISTURE CONTENT SHALL BE REPLACED OR ALLOWED TO DRY PRIOR TO ENCLOSURE IN WALL OR FLOOR CAVITIES. WET-APPLIED INSULATION PRODUCTS SHALL FOLLOW THE MANUFACTURERS' DRYING RECOMMENDATIONS PRIOR TO ENCLOSURE. 4.506 INDOOR AIR QUALITY AND EXHAUST 4.506.1 BATHROOM EXHAUST FANS. EACH BATHROOM SHALL BE MECHANICALLY VENTILATED AND SHALL COMPLY WITH THE FOLLOWING: 1. FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING. 2. UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDITY CONTROL. A. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE LESS THAN OR EQUAL TO 50% TO A MAXIMUM OF 80%. A HUMIDITY CONTROL MAY UTILIZE MANUAL OR AUTOMATIC MEANS OF ADJUSTMENT. B. A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO THE EXHAUST FAN AND IS NOT REQUIRED TO BE INTEGRAL (I.E., BUILT-IN) NOTES: 1. FOR THE PURPOSES OF THIS SECTION, A BATHROOM IS A ROOM WHICH CONTAINS A BATHTUB, SHOWER OR TUB/SHOWER COMBINATION. 2. LIGHTING INTEGRAL TO BATHROOM EXHAUST FANS SHALL COMPLY WITH THE CALIFORNIA ENERGY CODE. TABLE 4.504.2 - SEALANT VOC LIMIT (LESS WATER AND LESS EXEMPT COMPOUNDS IN GRAMS PER LITER) SEALANTS CURRENT VOC LIMIT ARCHITECTURAL 250 MARINE DECK 760 NONMEMBRANE ROOF 300 ROADWAY 250 SINGLE-PLY ROOF MEMBRANE 450 OTHER 420 SEALANT PRIMERS ARCHITECTURAL NON-POROUS 250 POROUS 775 MODIFIED BITUMINOUS 500 MARINE DECK 760 OTHER 750 TABLE 4.504.3 - VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS2,3 GRAMS OF VOC PER LITER OF COATING, LESS WATER & LESS EXEMPT COMPOUNDS COATING CATEGORY CURRENT VOC LIMIT FLAT COATINGS 50 NON-FLAT COATINGS 100 NONFLAT-HIGH GLOSS COATINGS 150 SPECIALTY COATINGS ALUMINUM ROOF COATINGS 400 BASEMENT SPECIALTY COATINGS 400 BITUMINOUS ROOF COATINGS 50 BITUMINOUS ROOF PRIMERS 350 BOND BREAKERS 350 CONCRETE CURING COMPOUNDS 350 CONCRETE/MASONRY SEALERS 100 DRIVEWAY SEALERS 50 DRY FOG COATINGS 150 FAUX FINISHING COATINGS 350 FIRE RESISTIVE COATINGS 350 FLOOR COATINGS 100 FORM-RELEASE COMPOUNDS 250 GRAPHIC ARTS COATINGS (SIGN PAINTS)500 HIGH TEMPERATURE COATINGS 420 INDUSTRIAL MAINTENANCE COATINGS 250 LOW SOLIDS COATINGS1 120 MAGNESITE CEMENT COATINGS 450 MASTIC TEXTURE COATINGS 100 METALLIC PIGMENTED COATINGS 500 MULTICOLOR COATINGS 250 PRETREATMENT WASH PRIMERS 420 PRIMERS, SEALERS, & UNDERCOATERS 100 REACTIVE PENETRATING SEALERS 350 RECYCLED COATINGS 250 ROOF COATINGS 50 RUST PREVENTATIVE COATINGS 250 SHELLACS CLEAR 730 OPAQUE 550 SPECIALTY PRIMERS, SEALERS & UNDERCOATERS 100 STAINS 250 STONE CONSOLIDANTS 450 SWIMMING POOL COATINGS 340 TRAFFIC MARKING COATINGS 100 TUB & TILE REFINISH COATINGS 420 WATERPROOFING MEMBRANES 250 WOOD COATINGS 275 WOOD PRESERVATIVES 350 ZINC-RICH PRIMERS 340 1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER & EXEMPT COMPOUNDS 2. THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT COLUMNS IN THE TABLE. 3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, FEB. 1, 2008. MORE INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD. CHAPTER 7 INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS 702 QUALIFICATIONS 702.1 INSTALLER TRAINING. HVAC SYSTEM INSTALLERS SHALL BE TRAINED AND CERTIFIED IN THE PROPER INSTALLATION OF HVAC SYSTEMS INCLUDING DUCTS AND EQUIPMENT BY A NATIONALLY OR REGIONALLY RECOGNIZED TRAINING OR CERTIFICATION PROGRAM. UNCERTIFIED PERSONS MAY PERFORM HVAC INSTALLATIONS WHEN UNDER THE DIRECT SUPERVISION AND RESPONSIBILITY OF A PERSON TRAINED AND CERTIFIED TO INSTALL HVAC SYSTEMS OR CONTRACTOR LICENSED TO INSTALL HVAC SYSTEMS. EXAMPLES OF ACCEPTABLE HVAC TRAINING AND CERTIFICATION PROGRAMS INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING: 1. STATE CERTIFIED APPRENTICESHIP PROGRAMS. 2. PUBLIC UTILITY TRAINING PROGRAMS. 3. TRAINING PROGRAMS SPONSORED BY TRADE, LABOR OR STATEWIDE ENERGY CONSULTING OR VERIFICATION ORGANIZATIONS. 4. PROGRAMS SPONSORED BY MANUFACTURING ORGANIZATIONS. 5. OTHER PROGRAMS ACCEPTABLE TO THE ENFORCING AGENCY. 702.2 SPECIAL INSPECTION [HCD]. WHEN REQUIRED BY THE ENFORCING AGENCY, THE OWNER OR THE RESPONSIBLE ENTITY ACTING AS THE OWNER'S AGENT SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO PROVIDE INSPECTION OR OTHER DUTIES NECESSARY TO SUBSTANTIATE COMPLIANCE WITH THIS CODE. SPECIAL INSPECTORS SHALL DEMONSTRATE COMPETENCE TO THE SATISFACTION OF THE ENFORCING AGENCY FOR THE PARTICULAR TYPE OF INSPECTION OR TASK TO BE PERFORMED. IN ADDITION TO OTHER CERTIFICATIONS OR QUALIFICATIONS ACCEPTABLE TO THE ENFORCING AGENCY, THE FOLLOWING CERTIFICATIONS OR EDUCATION MAY BE CONSIDERED BY THE ENFORCING AGENCY WHEN EVALUATING THE QUALIFICATIONS OF A SPECIAL INSPECTOR: 1. CERTIFICATION BY A NATIONAL OR REGIONAL GREEN BUILDING PROGRAM OR STANDARD PUBLISHER. 2. CERTIFICATION BY A STATEWIDE ENERGY CONSULTING OR VERIFICATION ORGANIZATION, SUCH AS HERS RATERS, BUILDING PERFORMANCE CONTRACTORS, AND HOME ENERGY AUDITORS. 3. SUCCESSFUL COMPLETION OF A THIRD PARTY APPRENTICE TRAINING PROGRAM IN THE APPROPRIATE TRADE. 4. OTHER PROGRAMS ACCEPTABLE TO THE ENFORCING AGENCY. NOTES: 1. SPECIAL INSPECTORS SHALL BE INDEPENDENT ENTITIES WITH NO FINANCIAL I NTEREST IN THE MATERIALS OR THE PROJECT THEY ARE INSPECTING FOR COMPLIANCE WITH THIS CODE. 2. HERS RATERS ARE SPECIAL INSPECTORS CERTIFIED BY THE CALIFORNIA ENERGY COMMISSION (CEC) TO RATE HOMES IN CALIFORNIA ACCORDING TO THE HOME ENERGY RATING SYSTEM (HERS). [BSC] WHEN REQUIRED BY THE ENFORCING AGENCY, THE OWNER OR THE RESPONSIBLE ENTITY ACTING AS THE OWNER'S AGENT SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO PROVIDE INSPECTION OR OTHER DUTIES NECESSARY TO SUBSTANTIATE COMPLIANCE WITH THIS CODE. SPECIAL INSPECTORS SHALL DEMONSTRATE COMPETENCE TO THE SATISFACTION OF THE ENFORCING AGENCY FOR THE PARTICULAR TYPE OF INSPECTION OR TASK TO BE PERFORMED. IN ADDITION, THE SPECIAL INSPECTOR SHALL HAVE A CERTIFICATION FROM A RECOGNIZED STATE, NATIONAL OR INTERNATIONAL ASSOCIATION, AS DETERMINED BY THE LOCAL AGENCY. THE AREA OF CERTIFICATION SHALL BE CLOSELY RELATED TO THE PRIMARY JOB FUNCTION, AS DETERMINED BY THE LOCAL AGENCY. NOTE: SPECIAL INSPECTORS SHALL BE INDEPENDENT ENTITIES WITH NO FINANCIAL INTEREST IN THE MATERIALS OR THE PROJECT THEY ARE INSPECTING FOR COMPLIANCE WITH THIS CODE. 703 VERIFICATIONS 703.1 DOCUMENTATION. DOCUMENTATION USED TO SHOW COMPLIANCE WITH THIS CODE SHALL INCLUDE BUT IS NOT LIMITED TO, CONSTRUCTION DOCUMENTS, PLANS, SPECIFICATIONS, BUILDER OR INSTALLER CERTIFICATION, INSPECTION REPORTS, OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY WHICH DEMONSTRATE SUBSTANTIAL CONFORMANCE. WHEN SPECIFIC DOCUMENTATION OR SPECIAL INSPECTION IS NECESSARY TO VERIFY COMPLIANCE, THAT METHOD OF COMPLIANCE WILL BE SPECIFIED IN THE APPROPRIATE SECTION OR IDENTIFIED APPLICABLE CHECKLIST. DIVISION 4.5 ENVIRONMENTAL QUALITY (CONTINUED) TABLE 4.504.5 - FORMALDEHYDE LIMITS1 MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION PRODUCT CURRENT LIMIT HARDWOOD PLYWOOD VENEER CORE 0.05 HARDWOOD PLYWOOD COMPOSITE CORE 0.05 PARTICLE BOARD 0.09 MEDIUM DENSITY FIBERBOARD 0.11 THIN MEDIUM DENSITY FIBERBOARD2 0.13 1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIF. AIR RESOURCES BOARD, AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE WITH ASTM E 1333. FOR ADDITIONAL INFORMATION, SEE CALIF. CODE OF REGULATIONS, TITLE 17, SECTIONS 93120 THROUGH 93120.12. 2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 5/16" (8 MM). 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE-RESIDENTIAL MANDATORY MEASURES 4.507 ENVIRONMENTAL COMFORT 4.507.2 HEATING AND AIR-CONDITIONING SYSTEM DESIGN. HEATING AND AIR CONDITIONING SYSTEMS SHALL BE SIZED, DESIGNED AND HAVE THEIR EQUIPMENT SELECTED USING THE FOLLOWING METHODS: 1. THE HEAT LOSS AND HEAT GAIN IS ESTABLISHED ACCORDING TO ANSI/ACCA 2 MANUAL J - 2011 (RESIDENTIAL LOAD CALCULATION), ASHRAE HANDBOOKS OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS. 2. DUCT SYSTEMS ARE SIZED ACCORDING TO ANSI/ACCA 1 MANUAL D - 2014 (RESIDENTIAL DUCT SYSTEMS), ASHRAE HANDBOOKS OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS. 3. SELECT HEATING AND COOLING EQUIPMENT ACCORDING TO ANSI/ACCA 3 MANUAL S - 2014 (RESIDENTIAL EQUIPMENT SELECTION), OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS. EXCEPTION: USE OF ALTERNATE DESIGN TEMPERATURES NECESSARY TO ENSURE THE SYSTEM FUNCTIONS ARE ED ACCEPTABLE. 447.50' 449.30 449.50' 450.00' 447.25' G / M A/C 447.40' 449.50'449.50'449.50'449.50' 449.25' 450.17'450.17'450.17' 450.00' 449.50' 450.00' 450.00' 450.00' 450.17' G / M ELEC G / MELECG / M A/C 450.00' 449.50' 450.00'450.00' ELEC ELEC 447.11' 446.63'445.67' 441.80'441.00' ±6'-3"32'-10"32'-10"27'-10"32'-10" 30 ' - 0 " ±6'-3"32'-10"32'-10"27'-10"32'-10" 441.00' 441.00' 440.50' A/C A/C 440.50' 440.50'440.50' 440.58' 447.11' 446.63'445.67' 441.80'441.00' 441.00' 440.55' 440.63' ±6'-3"32'-10"32'-10"27'-10"32'-10" 30 ' - 0 " Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update A0.7 CODE ANALYSIS DIAGRAM - SITE PLAN 1 CODE ANALYSIS 1 1 ALL OTHERS5 < X < 10 < 5 FIRE SEPARATION DISTANCE: X (FT) TYPE OF CONSTRUCTION OCCUPANCY R, U OCCUPANCY SEPARATION: (2022 CBC TABLE 508.4) 1. REQUIRED SEPARATION OF OCCUPANCY (HRS) FOR R-3 & U = 1 HR. 200 GROSSR-3 ENCLOSED GARAGE RESIDENTIAL OCCUPANCY (FT) W/O SPRINKLER (FT) W/ SPRINKLER 200R 250 300U 400 FIRE RESISTANCE RATINGS REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE: (2022 CBC TABLE 602) 10 OCCUPANCY R NOTE: 1. WHERE TWO EXITS OR EXIT ACCESS DOORWAYS ARE REQUIRED FROM ANY PORTION OF THE EXIT ACCESS, THE SEPARATION DISTANCE OF THE EXIT DOORS OR EXIT ACCESS DOORWAYS SHALL NOT BE LESS THAN ONE-THIRD OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREA SERVED. 2. WHERE A BLDG IS EQUIPPED WITH AUTOMATIC SPRINKLER SYSTEM, IN ACCORDANCE WITH SEC 903.3.1 OR 903.3.2. SPACES W/ ONE EXIT OR EXIT ACCESS DOORWAY: (2022 CBC TABLE 1006.2.1) MAXIMUM OCCUPANT LOAD OCCUPANCY LOAD: (2022 CBC TABLE 1004.1.2) 2 ALLOWABLE HEIGHT & BLDG AREA (2022 CBC TABLE 504.4 AND 506.2) R-3, U TYPE V-B 3ULBLDG 1 SPRINKLERED (S13D) EXIT ACCESS TRAVEL DISTANCE: (2022 CBC TABLE 1016.2) BLDG 1 OC: R-3 TYPE V-B, SPRINKLERED FLOOR AREA NUMBER OF STORIES OCCU- PANCY CONSTRUCT- ION TYPE ALLOWABLE AREA ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLAN 2R-3: 3,861 SF R-3, U TYPE V-B 3ULBLDG 2 U: 2,618 SF* SPRINKLERED (S13D) R-3: 3,257 SF U: 2,328 SF* OCCUPANT LOAD FACTOROCCU- PANCY FUNCTION OF SPACE NOTE: 1. WHEN EQUIPPED THROUGHOUT WITH AN AUTOMATIC RESIDENTIAL FIRE SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3., THE FIRE-RESISTANCE RATING SHALL NOT BE REQUIRED WHEN THE FIRE SEPARATION IS 3 FT OR MORE. BLDG 2 OC: R-3 TYPE V-B, SPRINKLERED SCALE: 3/32" = 1'-0" NORTH DIAGRAM - BASEMENT PLAN 2 SCALE: 3/32" = 1'-0" NORTH UNIT 1 GARAGE UNIT 2 GARAGE DIAGRAM - SECTION 3 SCALE: 3/32" = 1'-0" OPEN TO ABOVE BLDG 1 OC: R-3 TYPE V-B, SPRINKLERED BLDG 2 OC: R-3 TYPE V-B, SPRINKLERED UNIT 2 GARAGEUNIT 3 GARAGEUNIT 4 GARAGE UNIT 1 GARAGE UNIT 1UNIT 2UNIT 3UNIT 4 ENCLOSED GARAGE OC: U TYPE V-B, SPRINKLERED OPEN TO ABOVE 200 GROSS 49U ENCLOSED GARAGE OC: U TYPE V-B, SPRINKLERED BLDG 1 ENCLOSED GARAGE OC: U TYPE V-B, SPRINKLERED U UNIT 4 GARAGE BLDG 2 ENCLOSED GARAGE OC: U TYPE V-B, SPRINKLERED UNIT 3 GARAGE OPEN TO ABOVE OPEN TO ABOVE UNIT 4 UNIT 3 UNIT 2 UNIT 1 UNIT 4 STAIRS OC: R-3 UNIT 3 STAIRS OC: R-3 UNIT 2 STAIRS OC: R-3 UNIT 1 STAIRS OC: R-3 1-HR WALL SEPARATION 1-HR WALL SEPARATION 1-HR WALL SEPARATION 1-HR FLOOR/CEILING SEPARATION1-HR FLOOR/CEILING SEPARATION NOTE: *THE AREA OF A PRIVATE GARAGE ACCESSORY TO GROUP R-3 ONE- OR TWO FAMILY DWELLINGS SHALL NOT BE GREATER THAN 3,000 SF IN AREA (SECTION 406.3.1, EXCEPTION) 1-HR WALL SEPARATION 1-HR WALL SEPARATION ALLOWABLE AREA DIAGRAM 4 SCALE: 3/32" = 1'-0" TOTAL AREA OF OPENING: 144 SF TOTAL AREA OF EXTERIOR WALL: 1,100 SF 136 SF / 1,081 SF X 100 =13.09% FIRE SEPARATION DISTANCE (FT) MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION (2022 CBC TABLE 705.8) DEGREE OF OPENING PROTECTION ALLOWABLE AREA 0 TO < 3' UNPROTECTED, NONSPRINKLERED (UP, NS) UNPROTECTED, SPRINKLERED (UP, S) PROTECTED (P) UNPROTECTED, NONSPRINKLERED (UP, NS) UNPROTECTED, SPRINKLERED (UP, S) PROTECTED (P) 3 TO < 5' NOT PERMITTED NOT PERMITTED NOT PERMITTED NOT PERMITTED 15% 15% UNPROTECTED, NONSPRINKLERED (UP, NS) UNPROTECTED, SPRINKLERED (UP, S) PROTECTED (P) 5 TO < 10' 10% 25% 25% UNIT 2 AND 3 WALL OPENING IM A G I N A R Y P R O P E R T Y L I N E IM A G I N A R Y P R O P E R T Y L I N E IM A G I N A R Y P R O P E R T Y L I N E S8 9 ° 3 7 ' 5 3 " W 50 . 0 4 N8 9 ° 3 4 ' 5 6 " E 50 . 0 3 N00°25'02"W 169.06 N00°25'14"W 169.10 GE N O A S T AL L E Y W A Y 447.50' 449.30 449.50' 450.00' 447.25' 447.40' 449.50'449.50'449.50'449.50' 449.25' 450.17'450.17'450.17' 450.00' 449.50' 450.00' 450.00' 450.00' 450.17' 450.00' 449.50' 450.00'450.00' 447.11' 446.63'445.67' 441.80'441.00' 157 GENOA 1-STORY MULTI-FAMILY UNIT BUILT IN 1926 1,116 SF 159 GENOA 1-STORY MULTI-FAMILY UNIT BUILT IN 1955 746 SF SCALE: 1/16" = 1'-0" OVERALL SITE DEMOLITION PLAN 1 NORTH 4 3 2 5 6 7 1 EXISTING BRICK EDGING AND DRIVEWAY TO BE REMOVED ENTIRELY EXISTING WOOD FENCE TO BE REMOVED EXISTING 9" DIA, CRAPE MYRTLE TREE (UNPROTECTED) PER ARBORIST REPORT TO BE REMOVED EXISTING CONCRETE BLOCK WALL TO BE REMOVED EXISTING HARDSCAPE AREA TO BE REMOVED EXISTING 1-STORY MULTI-FAMILY HOUSING UNIT TO BE REMOVED, SEE SHEET NOTE M13/A0.4 EXISTING WATER METER TO BE RELOCATED (PER SITE PLAN) 2 134 4 2 5 66 2 7 5 8 8 EXISTING CURB CUT AND PORTION OF SIDEWALK TO BE REMOVED PER CITY OF ARCADIA STANDARDS PROJECT HAS ZERO ON-SITE OR NEARBY OFF-SITE OAK SPECIES TREES OVERALL SITE DEMOLITION PLAN SITE DEMOLITION PLAN NOTES A1.0 2 2 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 1 9 REMOVE EXISTING BRICK PORTCH AND STEP 10 EXISTING SIDEWALK TO REMAIN 9 10 GUEST PARKING (PARALLEL PARKING) S8 9 ° 3 7 ' 5 3 " W 50 . 0 4 N8 9 ° 3 4 ' 5 6 " E 50 . 0 3 N00°25'02"W 169.06 N00°25'14"W 169.10 GE N O A S T AL L E Y W A Y 13R DN 4R UP 447.50' 449.30 449.50' 450.00' 447.25' G / M A/C 11'-6"11'-6" MIN. 447.40'5R UP OPEN SPACE 121 SF 12'-1" 10 ' - 0 " 449.50'449.50'449.50'449.50' 449.25' UNIT 2 TYPE B 450.17' UNIT 3 TYPE B 450.17' UNIT 4 TYPE B2 450.17' BLDG 2 OPEN TO BELOW OPEN SPACE 328 SF OPEN SPACE 207 SF 450.00' 449.50' 450.00' ±6'-3" 8'-0"8'-0"8'-0"12'-6"4'-0"4'-0" 16'-2"16'-8"11'-3" 11'-8 1/2" 4'-2" 4'-0" 25'-0"FRONT YARD SETBACK (25'-0" MIN.) 11'-6 1/2"132'-7" 32'-10"32'-10" 11'-6"25'-0"FRONT YARD SETBACK (25'-0" MIN.) 132'-7" 32'-10" 5' - 0 " 18 ' - 6 " 5' - 6 " 4' - 6 " 4' - 8 " 30 ' - 0 " 10 ' - 0 " 10 ' - 0 " 3' - 1 0 " 26 ' - 2 " 4'- 6 " 5'- 6 " 10 ' - 0 " 30 ' - 0 " 10 ' - 0 " 9'-6" 12'-5"16'-2"±6'-3" 19'-4" 27'-10" 5'-0" 4'-0" 16'-8"16'-8"16'-2" 5' - 0 " 5' - 0 " 13'-1 1/2"4'-0"24'-10" 450.00' 450.00' 4'-10"15'-2" 4' - 6 " 5' - 6 " UNIT 1 TYPE A 450.17' BLDG 1 G / M TRASH ELEC 16'-4" OPEN SPACE 328 SFG / MELECG / M A/C 450.00' 449.50' 450.00' 10'-0" 6'- 6 " 10'-0"ALLEY WIDTH 8'-6"3'-0" 11 ' - 6 " 10 ' - 6 " 5'-0"5'-0" 10'-0" PARKWAY WIDTH 24 ' - 2 " 5'-9"3'-0" MIN. 16R DN 450.00' 5' - 0 " 4'- 6 " 4'- 6 " 4'- 6 " ELEC ELEC 1' - 0 " 4' - 0 " 2'- 1 0 " 447.11' 446.63'445.67' 12% DN 6% DN441.80' 20% DN 10% DN 441.00' R2 5 ' - 0 " R2 5 ' - 0 " 4' - 0 " ADJACENT DWELLING 447.50' 449.30 449.50' 450.00' 447.25' 447.40' 449.50'449.50'449.50'449.50' 449.25' 450.17'450.17'450.17' 450.00' 449.50' 450.00' 450.00' 450.00' 450.17' 450.00' 449.50' 450.00'450.00' 447.11' 446.63'445.67' 441.80'441.00' ADJACENT DWELLING A1.1 SITE PLAN SCALE: 1/8" = 1'-0" OVERALL SITE PLAN 1 NORTH A 1 B 2 CDEF 1 2 2 A4.2 1 A4.1 2 A4.1 1 A4.3 4 11 12 5 7 9 2 17 795 7 10 15 8 9 5 4 8 5 5 39 18 104 13 18 948 9 24 7 10 13 9 12 14 19 9 13 12 5 10 4 9 16 16 16 96 4 3 2 5 6 9 7 12 8 11 1 NEW CONCRETE DRIVEWAY.1-4 AD1 10 13 14 NEW CURB CUT PER CITY OF ARCADIA STANDARDS. NEW CONCRETE MASONRY UNIT RETAINING WALL PER STRUCT.AND NEW CONCRETE MASONRY UNIT WALL, HEIGHT PER ELEVATION. NEW CONCRETE WALKWAY AND STEPS. NEW BASEMENT EXHAUST SHAFT. LANDSCAPE PER LANDSCAPE DRAWINGS. NEW WOOD DECK W/ ELASTOMERIC/WATERPROOFED FINISH. NEW WOOD GATE AND OR FENCE PER ELEVATION AND NEW TREE PER LANDSCAPE DRAWINGS. GUEST PARKING SPACE PER CITY OF ARCADIA STANDARDS. GAS METER LOCATION, COORDINATE W/ PLUMBING DISCIPLINE EXISTING WATER METER LOCATION. 15 TRASH ENCLOSURE PER CITY OF ARCADIA STANDARDS (9'W x 6"d x 6'H MIN.) 16 BERM, SEE SECTION 1/A5.1 AND COORDINATE W/ LANDSCAPING DISCIPLINE 17 EXISTING SIDEWALK TO BE IMPROVED PER CITY OF ARCADIA STANDARDS. 18 NEW 'MITSUBISHI' MXZ-4C36NAHZ HEAT PUMP UNIT PER ENERGY CALCULATIONS 10.10, SEER: 15.80, EER: 11.30 (SET ON EQUIPMENT CONCRETE PAD) 19 20 NEW 6" CURB PER GRADING DRAWINGS. NOTE: A BOUNDARY AND TOPOGRAPHIC SURVEY WAS CONDUCTED BY EGL ASSOCIATES INC., A LICENSED SURVEYOR. ALL PROPERTY LINES, SETBACKS, EASEMENTS, FENCES, BUILDING CORNERS, TOPOGRAPHIC LINES, SPOT ELEVATIONS, AND OTHER LEGAL PARCEL-SPECIFIC LINEWORK SHOWING IN THIS DRAWING SET WERE SOURCED FROM THE SURVEYOR'S PROVIDED MAP. EXISTING SIGN POST TO REMAIN. SITE PLAN NOTES ELECTRIC METER LOCATION, COORDINATE W/ ELECTRICAL DISCIPLINE 11 AD1 6,7 AD1 9 AD1 4 AD4 4 AD4 1-2 AD1 1 A4.2 1 A4.4 2 A4.4 2 A4.3 1 A6.3 1 A5.1 1 A5.2 2 A5.1 2 A5.2 1 A5.3 2 A5.3 SCALE: 1/8" = 1'-0" SITE LIGHTING PLAN 2 NORTH TO TIMER ±6'-5"22'-6" 6'-0"22'-6"TYP. TO TIMER AND PHOTOCELL SEE 1/A2.6 TO TIMER AND PHOTOCELL 8 AD1 RECESSED LIGHT IN CMU BLOCK WALL PER OWNER, 24" A.F.F. 12,16 A6.2 17,18 AD5 11 AD4 5 AD11'-9" EQ . EQ . 22'-6" 1 1 TYP. 10 2 102 21 NEW 'MITSUBISHI' MXZ-8C60NA HEAT PUMP UNIT PER ENERGY CALCULATIONS HSPF/COP: 10.00, SEER: 15.10, EER: 9.60 (SET ON CONCRETE EQUIPMENT PAD) 1 1 NOTE: PHOTOCONTROLS AND TIMERS SHALL COMPLY WITH §110.9(B)1 AND 2 TO LIGHT, Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 23 8 8 7 1 22 22 7 7 5 94 5 22 EXISTING SIDEWALK MODIFY AT NEW APRON) 23 PROVIDE CONCRETE WHEELSTOP 24 8" STEEL PIPE BOLLARD, SEE DETAIL 19/A6.2 UP 14R 2-CAR GARAGE 394 SF 2' - 1 0 " 16 ' - 0 " 4' - 4 " 2'- 2 " 25 ' - 4 " SLOPE DN 2" 21 ' - 0 " 4' - 4 " 25 ' - 4 " 15'-4" WH 19'-4 1/2" 20 ' - 4 " 1 5'-0"15'-4" 11"10'-10" 13 5'-0" 4" 4'-0" 441.00'13R UP 15R UP 441.00' ±6'-3" 8'-0"8'-0"8'-0"3'-6"20'-4"20'-4"12'-6" 20'-4"25'-0"20'-4"11'-2" 12'-5 1/2" 4'-2" 12'-6" 25'-0"FRONT YARD SETBACK (25'-0" MIN.) 11'-6 1/2"132'-7" 32'-10"32'-10" 11'-6"25'-0"FRONT YARD SETBACK (25'-0" MIN.) 132'-7" 32'-10" 5' - 0 " 5' - 0 " 25 ' - 4 " 5' - 0 " 5' - 0 " 4' - 8 " 30 ' - 0 " 10 ' - 0 " 10 ' - 0 " 3' - 1 0 " 26 ' - 2 " 5' - 6 " 4' - 6 " 10 ' - 0 " 30 ' - 0 " 10 ' - 0 " 9'-6" 25'-0"20'-4"±6'-3" 19'-4" 27'-10" GUEST PARKING 12 ' - 0 1 / 2 " PA R K I N G W I D T H (1 1 ' - 6 " M I N . ) 19'-8"PARKING LENGTH 19'-0" MIN. 25'-0"25'-0" MIN.25'-0"25'-0" MIN. 5'-0" UNIT 4 TYPE B2 UNIT 3 TYPE B UNIT 2 TYPE B UNIT 1 TYPE A 17 ' - 0 1 / 2 " 7'-10 1/2" 5' - 0 " 5' - 0 " 440.50' (2 ) B I C Y C L E LO C K E R 9'-0" 3'-0" A/C A/C OPEN TO ABOVE 440.50' 440.50'440.50' 4.42% DN 440.58' 447.11' 446.63'445.67' 12% DN 6% DN441.80' 20% DN 10% DN 441.00' 2' - 1 0 " R2 5 ' - 0 " R2 5 ' - 0 " 2'-6" 1' - 6 " 441.00' 440.55' 440.63' 2' - 1 0 " UP 14R 20'-4" 17 ' - 3 1 / 2 " 1'- 9 " 3'- 8 " 1' - 4 1 / 2 " 16 ' - 0 " 17 ' - 3 1 / 2 " 3'- 8 " 13 ' - 7 1 / 2 " 20'-4" 3'-8"16'-8" WH 19'-4 1/2" 3'-4"16'-0 1/2" 18 ' - 2 " 2-CAR GARAGE 351 SFSLOPE DN 2" 1 13 5'- 6 " 5'- 6 " 4" 4" A 1 B 2 CDEF 1 2 4 3 2 5 6 7 8 1 NEW CONCRETE DRIVEWAY.1-3 AD1 NEW CONCRETE RETAINING WALL PER STRUCT. NEW CONCRETE WALKWAY AND STEPS. NEW BASEMENT EXHAUST SHAFT. GUEST PARKING SPACE PER CITY OF ARCADIA STANDARDS. 'DURA' DL2 2-BIKE LOCKER UNIT. INSTALL PER MANUFACTURER SPECIFICATIONS AND INSTRUCTIONS. COLOR: GRAPHITE (PROVIDE 'PADLOCK' STYLE HANDLE NEW 6" AFTER-SET CURB AT GARAGE WALL OVERALL BASEMENT PLAN NOTES 11 AD1 17,18 AD5 1-2 AD1 4 3 2 1 LINE OF BUILDING ABOVE TANKLESS WATER HEATER PER ENERGY CALCULATIONS. PROVIDE VENT TO OUTSIDE OF GARAGE. BASEMENT FLOOR PLAN NOTES A1.2 BASEMENT PLANS SCALE: 1/8" = 1'-0" OVERALL BASEMENT PLAN 1 NORTH SCALE: 1/4" = 1'-0" ENLARGED TYPE A BASEMENT PLAN 2 NORTH SCALE: 1/4" = 1'-0" 3 NORTH ENLARGED TYPE B & B2 BASEMENT PLAN 213 4 3 6 5 5 7 8 1B A6.2 2B A6.2 N O T E: UN I T S 2 A N D 4 PL ANS SHOWN. UNIT 3 PLAN IS MIRRORED. ABGRIDGRID 2 2 1 A5.1 1 A5.2 2 A5.1 1 A5.2 1 A5.1 UNIT 2 UNIT 3 & 4 1 A5.1 2 A5.1 2 A5.2 1 A5.3 1 A5.3 UNIT 3 2 A5.3 UNIT 4 2 A5.3 1 AD5 BASEMENT WALL LEGEND 2X4 WOOD FRAMING PER STRUCT. DWGS. W/ GYP. BD. AT INTERIOR FINISH. 2X6 WOOD FRAMING PER STRUCT. DWGS. W/ GYP. BD. AT INTERIOR FINISH. 1 AD5 11 AD1 CONCRETE RETAINING WALL PER STRUCT. DWGS W/ GYP. BD FINISH (INTERIOR) AND EXT. PLASTER (EXTERIOR). 12,16 A6.2 8 AD1 1-4 AD2 WOOD FRAMING PER STRUCT. DWGS. W/ GYP. BD. AT INTERIOR FINISH AND EXT. PLASTER FINISH AT EXTERIOR. 4 GUARDRAIL/HANDRAIL AT STAIRS AND LANDING. HANDRAIL TO BE LOCATED 34"-36" ABOVE THE NOSE OF EACH TREAD. GUARDRAIL TO BE LOCATED 42" ABOVE THE FINISH FLOOR, TYP. SEE A6.1 FOR STAIR PLANS AND SECTION. 21 LANDINGS AT DOORS SHALL COMPLY WITH CRC R311.3.13,14,18 AD4 3 4 23 5 UNITS 2 AND 3: 2X FRAMED WALL PER STRUCT. UNIT 4:CONC. RETAINING WALL PER STRUCT. 5 9 9 TRENCH DRAIN PERCIVIL DISCIPLINE (ALIGN w/ WALL and CURB) 4 AD1 1 1 1 1 A6.3 1 NEW 'MITSUBISHI' MXZ-8C60NA HEAT PUMP UNIT PER ENERGY CALCULATIONS HSPF/COP: 10.00, SEER: 15.10, EER: 9.60 (SET ON CONCRETE EQUIPMENT PAD) Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 10 PRE-MFR. WHEELSTOP 2 10 SEE PLAN 3/A1.2 SEE PLAN 3/A1.2 OPP.SEE PLAN 3/A1.2 SEE PLAN 2/A1.2 3 1 SEE DOOR SCHEDULE SHEET A8.1 # SEE DOOR SCHEDULE SHEET A8.1 # 1 C-2 1 11 11 8" STEEL PIPE BOLLARD, SEE DETAIL 19/A6.2 9 WH TO LIGHT ABOVE S C +12 +12 3 CL EQ.EQ. 5' - 0 " 5'- 0 " 7'-2" 2" STEP IN DECK 5'-5 1/2" V EQ . EQ . TO HOUSE PANEL 441.00' 441.00' 440.50' A/C A/C 440.50' 440.50'440.50' 440.58' 447.11' 446.63'445.67' 441.80'441.00' 441.00' 440.55' 440.63' OPEN TO SKY 2" STEP IN DECK2" STEP IN DECK 2" STEP IN DECK TO TIMER AND PHOTOCELL TO TIMER AND PHOTOCELL 5' - 6 " 6' - 0 " 5' - 6 " 6' - 0 " EQ . EQ . 5' - 0 " TO TIMER 11'-10" 5'-7" 4'-6" HB HB HB WP WP EQ . EQ . WP 2" STEP IN DECK UNIT 4 TYPE B2 UNIT 3 TYPE B UNIT 2 TYPE B UNIT 1 TYPE A10'-0"EQ.EQ.10'-0"EQ.EQ. 16'-0"16'-0"11'-10"16'-0" WH TO LIGHT ABOVE S C +12 +12 3 5' - 0 " 5' - 0 " CL EQ.EQ. 2" STEP IN DECK 7'-2" V EQ . EQ . NOTE: OPPOSITE CONDITION OCCURS A 1 B 2 CDEF 1 2 1 CEILING PLAN NOTES CEILING LEGEND A1.3 BASEMENT REFLECTED CEILING PLANS SCALE: 1/8" = 1'-0" REFLECTED CEILING PLAN 1 NORTH SCALE: 1/4" = 1'-0" REFLECTED CEILING PLAN 2 NORTH SCALE: 1/4" = 1'-0" (UNIT 2 & 4 SHOWN, UNIT 3 MIRRORED)3 NORTH TYPE B & B2 BASEMENT REFLECTED CEILING PLAN OVERALL BASEMENT TYPE A BASEMENT 3 12"X48" SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE DOUBLE TUBE (MUST BE HIGH EFFICACY OR CONTROLLED BY A VACANCY SENSOR). LIGHT SWITCH. TWO WAY LIGHT SWITCH. V LIGHT SWITCH WITH VACANCY SENSOR S DUPLEX EXTERIOR G.F.C.I. ELECTRICAL OUTLET W/ WATER PROOF COVER. SMOKE DETECTOR/ALARM WALL MOUNTED HARDWIRED WITH BATTERY BACK-UP INTERCONNECTED. CARBON MONOXIDE DETECTOR/ALARM WALL MOUNTED HARDWIRED WITH BATTERY BACK-UP INTERCONNECTED. C WP DUPLEX EXTERIOR G.F.C.I. ELECTRICAL OUTLET @ 42" A.F.F. U.N.O. 6" DIA. RECESSED CAN LIGHT (HIGH EFFICACY). A/C DISCONNECT ALL CEILING HEIGHTS TO BE 7'-6" FOR BASEMENT FLOOR, U.N.O. ALL SWITCHES TO BE WHITE COLOR, DECORA FLAT BUTTON. (PROVIDE VACANCY SENSOR TO CONTROL LIGHTING WHERE NOTED) SMOKE DETECTORS MUST RECEIVE THEIR PRIMARY POWER FROM THE BLDG. WIRING & SHALL BE EQUIPPED W/ A BATTERY BACKUP. ALL NEW CIRCUITS SHALL BE AFCI PROTECTED. PROVIDE ARC-FAULT CURRENT INTERRUPTER FOR ALL NEW LIGHTING & RECEPTACLES. ALL RECESSED CEILING LIGHT SHALL BE UL APPROVED, IC UNITS FOR INSULATED SPACE WHERE OCCURS. EXTERIOR LIGHTS SHALL BE HOODED & ARRANGED TO REFLECT AWAY FROM ADJOINING PROPERTIES & STREET. MAX. HT. OF 15'-0" ABOVE GRADE. 2 4 3 6 5 9 8 7 ALL HOSE BIBBS MUST BE RECESSED AND EQUIPPED W/ AN APPROVED NON-REMOVABLE TYPE BACK FLOW PREVENTION DEVICE. SEE 603.4.7 OF THE CALIFORNIA PLUMBING CODE. BASEMENT EXHAUST SHAFT. SEE MECHANICAL DRAWINGS. AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL-BURNING APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. REQUIRED CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH A BATTERY BACK-UP. WHERE MORE THAN ONE CARBON MONOXIDE ALARM IS REQUIRED TO BE INSTALLED WITHIN THE DWELLING UNIT OR WITHIN A SLEEPING UNIT, THE ALARM SHALL BE INTERCONNECTED IN A MANNER THAT ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. PER CRC 315.1.2 AND CBC 420.4.1 10 PROVIDE POWER DUPLEX FOR GARAGE DOOR OPENER AT CEILING LINE OF DECK/BUILDING ABOVE12 ELECTRIC VEHICLE CHARGING (CALGREEN, SECTION 4.106.4) PERMIT by OTHERS) NOTE: CONTRACTOR TO INSTALL A LISTED RACEWAY TO ACCOMMODATE A DEDICATED 208/240- VOLT BRANCH CIRCUIT. THE RACEWAY SHALL NOT BE LESS THAN TRADE SIZE 1 (NOMINAL 1-INCH INSIDE DIAMETER). THE RACEWAY SHALL ORIGINATE AT THE MAIN SERVICE OR SUBPANEL AND SHALL TERMINATE INTO A LISTED CABINET, BOX, OR OTHER ENCLOSURE IN CLOSE PROXIMITY TO THE PROPOSED LOCATION OF AN EV CHARGER. RACEWAYS ARE REQUIRED TO BE CONTINUOUS AT ENCLOSED, INACCESSIBLE OR CONCEALED AREAS AND SPACES. THE SERVICE PANEL AND/OR SUBPANEL SHALL PROVIDE CAPACITY TO INSTALL A 40-AMPERE MINIMUM DEDICATED BRANCH CIRCUIT AND SPACES RESERVED TO PERMIT INSTALLATION OF A BRANCH CIRCUIT OVERCURRENT PROTECTIVE DEVICE. 11 12 7 12 12 11 12 TYP. 6 2 4 10 11 8TYP. 4 10 11 2 8 TYP. 6 LIGHT FIXTURE CEILING MOUNTED (HIGH EFFICACY). 5 9 TANKLESS WATER HEATER PER ENERGY CALCULATIONS. PROVIDE VENT TO OUTSIDE OF GARAGE.WH 1 1 1 13 GARAGE LIGHTING SHALL COMPLY WITH APPLICABLE REQUIREMENTS IN SECTIONS 110.9, 130.0, 130.1, 130.4, 140.6, AND 141.0 PER §150.0(K)5. PHOTOCONTROLS AND TIMERS SHALL COMPLY WITH §110.9(B)1 AND 2. GARAGE LIGHTING SHALL COMPLY WITH §130.1(D)3 13 1 1 113 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update SEE PLAN 3/A1.2 SEE PLAN 3/A1.2 OPP.SEE PLAN 3/A1.2 SEE PLAN 2/A1.2 EXTERIOR DUPLEX GFCI OUTLET AT CEILING A A PROVIDE DEDICATED POWER TO IRRIGATION SYSTEM FROM HOUSE CIRCUIT PANEL AS SPECIFIED BY MFR., SEE LANDSCAPE PLANS (WALL MOUNTED BOX LOCATED OUTSIDE OF UNIT #1 GARAGE) 3 KITCHEN 96 SF LT: 14 SF VT: 7 SF UP 18R DN 14R DINING ROOM 138 SF LT: 60 SF VT: 40 SF LIVING ROOM 220 SF LT: 81 SF VT: 41 SF 27'-9 1/2" 5'-8 1/2" 9' - 4 " 11 ' - 6 " 25 ' - 4 " 14 ' - 6 " 12'-10"14'-11 1/2" 4' - 6 " 6' - 4 " 1'- 6 " 25 ' - 4 " 27'-9 1/2" E 2 5 4'-8" 4 DW REF B POW DER 34 SF M 2' - 0 " A 5' - 6 " 5'-2"1'-7 1/2"2'-2" 9 3'- 6 " 3' - 4 1 / 2 " 2'-0"3'-6"5'-4"3'-2 1/2"5'-9"1'-10"3'-2 1/2"1'-0" 1/2" AIR GAP 1/2" AIR GAP 12 " G / M A/C ELEC 3. 6 % DN 1%DN 2% DN BEDROOM 2 122 SF LT: 33 SF VT: 16.5 SF BEDROOM 3 159 SF LT: 46.25 SF VT: 15 SF 27'-9 1/2" 12'-10"11'-3 1/2" 10 ' - 5 " 5' - 6 " 10 ' - 5 " 4' - 2 1 / 2 " 8'- 0 " 2'-6"4'-5 1/2" 3'- 0 " 6' - 3 " 10'-6"10'-4" 26 ' - 4 " 27'-9 1/2" A L 3'-8" A BATH 1 45 SF W/D BATH 2 45 SFW.I.C. 38 SFBEDROOM 1 102 SF LT: 33 SF VT: 16.5 SF DN 18R 26 ' - 4 " 3' - 1 0 1 / 2 " 1' - 0 " CE E 5'-2"1'-7 1/2"2'-2" EQ . EQ . 2'-8 1/2"6'-5" 9 7 7 7 8 11 12 9 10 6' - 3 1 / 2 " 3' - 1 1 1 / 2 " 6' - 1 1 " 5'-9 1/2"5'-6" 1'-6" 1/2" AIR GAP 1/2" AIR GAP 5' - 9 1 / 2 " 1'-6" 6" SCALE: 1/4" = 1'-0" ENLARGED 1ST FLOOR PLAN2 NORTH SCALE: 1/4" = 1'-0" ENLARGED 2ND FLOOR PLAN 1 NORTH A2.1 TYPE A ENLARGED FLOOR PLANS AB 2 AB 2 2 A5.1 2 A5.1 1 A5.1 1 A5.1 * CONTRACTOR TO FIELD VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB AND SHALL NOTIFY THE ARCHITECT FOR ANY DISCREPANCIES IMMEDIATELY BEFORE COMMENCING ANY WORK. ALL DIMENSIONS ARE TO FACE OF STUD, U.N.O. SEE PLANS AND WALL DETAILS. 1 LINE OF BUILDING/CANOPY ABOVE. 2 FLOORING PER OWNER, TYP. 3 LANDINGS AT DOORS SHALL COMPLY WITH CRC R311.3. 5 LAVATORY PER OWNER'S SPECIFICATIONS. LAVATORY FAUCETS TO HAVE MAXIMUM FLOW RATE OF 1.2 GPM PER CGBC 4.303.1. INSULATION AT ALL PLUMBING WALLS, WHERE OCCURS. 4 PLUMBING HOOK-UPS FOR NEW PLUMBING FIXTURES AND APPLIANCES IN KITCHEN. KITCHEN FAUCET TO HAVE MAXIMUM FLOW RATE OF 1.8 GPM PER CGBC 4.303.1. 6 THIN SET O/ SUBFLOOR. SELECTED BY OWNER.7 9 10 ALL SHOWERS & TUBS SHALL HAVE A PERMANENTLY ACCESSIBLE 12" SQUARE BATHTUB TRAP ACCESS OR USE A NON-SLIP JOINT TRAP 11 8 ALL SHOWERS & TUBS SHALL BE FINISHED BY MATERIALS WHICH ARE NOT ADVERSELY AFFECTED BY MOISTURE TO A MIN. HEIGHT OF 72" ABOVE THE DRAIN INLET. ALL SHOWERS AND TUB-SHOWERS SHALL HAVE EITHER A PRESSURE BALANCE OR A THERMOSTATIC MIXING VALVE. ALL SHOWERHEADS TO HAVE MAXIMUM FLOW RATE OF 1.8 GPM PER CGBC 4.303.1. 13 UPPER & LOWER CABINETS, FINISH PER OWNER, LOWER CABINETS ONLY AT RESTROOMS AND KITCHEN ISLAND. FRAMELESS BEVELED EDGE MIRROR MEDICINE CABINET. 14 15 PROVIDE SHELVES & POLE @ ALL CLOSET W/ 5/8" THK. X 12" D. MDF MELAMINE FINISH. 12 16 1/4" THK. CLEAR TEMP. GLASS, FRAMELESS SHOWER ENCLOSURE W/ CHROME DOOR HANDLE, HINGES & 12" TOWEL BAR. NOTE: CONTRACTOR TO PROVIDE MINIMUM 22" CLR. WIDTH DOOR. WATER CLOSETS (TOILETS) TO USE NO MORE THAN 1.28 GALLONS PER FLUSH PER CGBC 4.303.1. 17 18 19 20 GUARDRAIL/HANDRAIL AT STAIRS AND LANDING. HANDRAIL TO BE LOCATED 34"-36" ABOVE THE NOSE OF EACH TREAD. GUARDRAIL TO BE LOCATED 42" ABOVE THE FINISH FLOOR, TYP. SEE A6.1 FOR STAIR PLANS AND SECTION. NEW COUNTER TOP, SELECT PER OWNER. 21 22 23 STACKED WASHER/DRYER SHALL BE PROVIDED A MIN. 4" Ø SMOOTH, METAL EXHAUST DUCT, SHALL TERMINATE IN AN APPROVED LOCATION OUTSIDE OF THE BUILDING & SHALL HAVE A BACKDRAFT DAMPER. EXHAUST DUCT IS LIMITED TO 14'-0" W/ 2 ELBOWS. THIS SHALL BE REDUCED 2'-0" FOR EVERY ELBOW IN EXCESS OF 2. NOTE: PROVIDE VERTICAL VENT THROUGH THE TOP OF THE ROOF. VENT SHALL BE LESS THAN 14' IN LENGTH. KITCHEN COOKTOP AND HOOD PER OWNER'S SPECIFICATIONS. 24 25 42" H LOW WALL BASEMENT EXHAUST SHAFT 2 AD5 3,4 AD5 10 AD5 26 30" X 30" ATTIC ACCESS ABOVE. FREESTANDING TUB PER OWNER. FLOOR PLAN NOTES 36" REFRIGERATOR, SELECT PER OWNER.27 WALL LEGEND 2X4 WOOD FRAMING PER STRUCT. DWGS. W/ GYP. BD. INTERIOR FINISH. 2X6 WOOD FRAMING PER STRUCT. DWGS. W/ GYP. BD. INTERIOR FINISH. 1 AD1 1-4 AD2 9 AD5 2X6 WOOD FRAMING PER STRUCT. DWGS. W/ GYP. BD. INTERIOR FINISH. EXTERIOR FINISH PER ELEVATIONS, U.N.O. 20 A6.11 AD1 3 AD5 13,14,18 AD4 CANTILEVER CANOPY PREP/VEGETABLE SINK, SELECT PER OWNER. BALCONY GUARDRAIL. 17,18 AD5 20 A3.2 17,18 AD2 1 28 CEMENT, FIBER-CEMENT, FIBERMAT REINFORCED CEMENT, GLASS MAT GYPSUM OR FIBER-REINFORCED GYPSUM BACKERS SHALL BE USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN SHOWER AREAS. 1 31 29 30 LANDSCAPE PER LANDSCAPE DRAWINGS. WOOD DECK W/ ELASTOMERIC/WATERPROOFED FINISH. WOOD FENCE, HEIGHT PER ELEVATION. 9 AD1 4 AD4 32 GARAGE MECHANICAL EXHAUST SHAFT PER MECANICAL TYP. 2 8 9 10 11 18 5 13 12 21 7 22 12 6 13 19 7 5 11 18 14 15 8 9 10 11 18 17 4 16 1 7 11 18 7 11 18 6 14 5 19 3 3 614 17-20 AD117-20 AD1 25 25 1 28 28 1 31 TYP. 30 TYP. 30 1 TYP. 2 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 13 AD5 E 13 AD5 OPPOSITE 13 AD5 E 13 AD5 OPPOSITE UP 18R LIVING ROOM 232 SF LT: 72 SF VT: 48 SF 11'-11 1/2"11'-0"5'-8" 10'-8" 32'-9 1/2" 22'-1 1/2" 12 ' - 1 0 1 / 2 " 3' - 6 " 4'-2" BATH 1 46 SF 1' - 0 " 32'-9 1/2" 30 ' - 0 " C 3 5 4 42" REF DINING ROOM 269 SF LT: 78 SF VT: 40 SF DN 15R DW B BEDROOM 1 106 SF LT: 48 SF VT: 24 SF KITCHEN 129 SF LT:14 SF VT: 7 SF 11 ' - 1 1 / 2 " 2' - 6 " 3'-6 1/2" 5 F 9'-4" EQ.EQ.5'-8" 1' - 0 " 7 9 1/2" AIR GAP 3'-2 1/2" 7'-0 1/2" 3' - 1 0 " 7' - 4 " 3'-6"2'-0" 2' - 0 " 4'-10 1/2" 6'- 1 1 " 3' - 6 " 11 1/2" AIR GAP 12'-9 1/2"4'-11 1/2"5'-8 1/2" 16 ' - 1 1 / 2 " 30 ' - 0 " 12 ' - 1 0 1 / 2 " 2" 2"ELEC G / M 2%DN 2%DN DN 18R BEDROOM 3 123 SF LT: 48 SF VT: 24 SF MASTER BEDROOM 213 SF LT: 44 SF VT: 16.5 SF 3' - 6 " BEDROOM 2 134 SF LT: 36 SF VT: 12 SF BAY WINDOW AREA W.I.C. 42 SF 5'-8"6'-7 1/2"5'-6" 32'-9 1/2" 6'-11 1/2" 13 ' - 7 1 / 2 " 17'-7 1/2" 12 ' - 1 0 1 / 2 " 3' - 6 " 9'- 4 1 / 2 " 30 ' - 0 " 12 ' - 7 1 / 2 " 4'-3" 4'-0" W/D 7'-0" 1' - 0 " 1' - 0 " 4'-0" BATH 3 43 SF BATH 2 42 SF 32'-9 1/2" 30 ' - 0 " 1' - 6 " G J H M N M N 5 A 3'-11 1/2" 5' - 6 " D G 7 9 9 MASTER BATH 119 SF EQ.EQ.3'-10"3'-6 1/2"3'-2" EQ.EQ.3'-0"3'-3"1'-8 1/2" 7 10 99 7 8 12 1' - 6 " 3' - 1 0 " 8' - 9 " 4'-0"1'-4" 3' - 6 " 8 1/2" AIR GAP 1/2" AIR GAP 5'-0" 3' - 1 0 " 3'- 0 " 5'-7 1/2" 14'-9" 1' - 0 " 3'-8 1/2" A2.2 TYPE B ENLARGED FLOOR PLANS SCALE: 1/4" = 1'-0" ENLARGED 1ST FLOOR PLAN2 NORTH SCALE: 1/4" = 1'-0" ENLARGED 2ND FLOOR PLAN 1 NORTH 1 A5.2 1 A5.2 NOTE: 2 A5.2 2 A5.2 1 A5.1 1 A5.1 UNIT 2 UNIT 3 UNIT 2 UNIT 3 UNIT 2 UNIT 2 1 A5.3 1 A5.3 UNIT 3 UNIT 3 2 1 2 1 BC * CONTRACTOR TO FIELD VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB AND SHALL NOTIFY THE ARCHITECT FOR ANY DISCREPANCIES IMMEDIATELY BEFORE COMMENCING ANY WORK. ALL DIMENSIONS ARE TO FACE OF STUD, U.N.O. SEE PLANS AND WALL DETAILS. 1 LINE OF BUILDING/CANOPY ABOVE. 2 FLOORING PER OWNER, TYP. 3 LANDINGS AT DOORS SHALL COMPLY WITH CRC R311.3. 5 LAVATORY PER OWNER'S SPECIFICATIONS. LAVATORY FAUCETS TO HAVE MAXIMUM FLOW RATE OF 1.2 GPM PER CGBC 4.303.1. INSULATION AT ALL PLUMBING WALLS, WHERE OCCURS. 4 PLUMBING HOOK-UPS FOR NEW PLUMBING FIXTURES AND APPLIANCES IN KITCHEN. KITCHEN FAUCET TO HAVE MAXIMUM FLOW RATE OF 1.8 GPM PER CGBC 4.303.1. 6 THIN SET O/ SUBFLOOR. SELECTED BY OWNER.7 9 10 ALL SHOWERS & TUBS SHALL HAVE A PERMANENTLY ACCESSIBLE 12" SQUARE BATHTUB TRAP ACCESS OR USE A NON-SLIP JOINT TRAP 11 8 ALL SHOWERS & TUBS SHALL BE FINISHED BY MATERIALS WHICH ARE NOT ADVERSELY AFFECTED BY MOISTURE TO A MIN. HEIGHT OF 72" ABOVE THE DRAIN INLET. ALL SHOWERS AND TUB-SHOWERS SHALL HAVE EITHER A PRESSURE BALANCE OR A THERMOSTATIC MIXING VALVE. ALL SHOWERHEADS TO HAVE MAXIMUM FLOW RATE OF 1.8 GPM PER CGBC 4.303.1. 13 UPPER & LOWER CABINETS, FINISH PER OWNER, LOWER CABINETS ONLY AT RESTROOMS AND KITCHEN ISLAND. FRAMELESS BEVELED EDGE MIRROR MEDICINE CABINET. 14 15 PROVIDE SHELVES & POLE @ ALL CLOSET W/ 5/8" THK. X 12" D. MDF MELAMINE FINISH. 12 16 1/4" THK. CLEAR TEMP. GLASS, FRAMELESS SHOWER ENCLOSURE W/ CHROME DOOR HANDLE, HINGES & 12" TOWEL BAR. NOTE: CONTRACTOR TO PROVIDE MINIMUM 22" CLR. WIDTH DOOR. WATER CLOSETS (TOILETS) TO USE NO MORE THAN 1.28 GALLONS PER FLUSH PER CGBC 4.303.1. 17 18 19 20 GUARDRAIL/HANDRAIL AT STAIRS AND LANDING. HANDRAIL TO BE LOCATED 34"-36" ABOVE THE NOSE OF EACH TREAD. GUARDRAIL TO BE LOCATED 42" ABOVE THE FINISH FLOOR, TYP. SEE A6.1 FOR STAIR PLANS AND SECTION. NEW COUNTER TOP, SELECT PER OWNER. 21 22 23 STACKED WASHER/DRYER SHALL BE PROVIDED A MIN. 4" Ø SMOOTH, METAL EXHAUST DUCT, SHALL TERMINATE IN AN APPROVED LOCATION OUTSIDE OF THE BUILDING & SHALL HAVE A BACKDRAFT DAMPER. EXHAUST DUCT IS LIMITED TO 14'-0" W/ 2 ELBOWS. THIS SHALL BE REDUCED 2'-0" FOR EVERY ELBOW IN EXCESS OF 2. NOTE: PROVIDE VERTICAL VENT THROUGH THE TOP OF THE ROOF. VENT SHALL BE LESS THAN 14' IN LENGTH. KITCHEN COOKTOP AND HOOD PER OWNER'S SPECIFICATIONS. 24 25 42" H LOW WALL BASEMENT EXHAUST SHAFT 2 AD5 3,4 AD5 10 AD5 26 30" X 30" ATTIC ACCESS ABOVE. FREESTANDING TUB PER OWNER. FLOOR PLAN NOTES 36" REFRIGERATOR, SELECT PER OWNER.27 WALL LEGEND 2X4 WOOD FRAMING PER STRUCT. DWGS. W/ GYP. BD. INTERIOR FINISH. 2X6 WOOD FRAMING PER STRUCT. DWGS. W/ GYP. BD. INTERIOR FINISH. 1 AD1 1-4 AD2 9 AD5 2X6 WOOD FRAMING PER STRUCT. DWGS. W/ GYP. BD. INTERIOR FINISH. EXTERIOR FINISH PER ELEVATIONS, U.N.O. 20 A6.11 AD1 3 AD5 13,14,18 AD4 CANTILEVER CANOPY PREP/VEGETABLE SINK, SELECT PER OWNER. BALCONY GUARDRAIL. 17,18 AD5 20 A3.2 17,18 AD2 1 28 CEMENT, FIBER-CEMENT, FIBERMAT REINFORCED CEMENT, GLASS MAT GYPSUM OR FIBER-REINFORCED GYPSUM BACKERS SHALL BE USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN SHOWER AREAS. 1 31 29 30 LANDSCAPE PER LANDSCAPE DRAWINGS. WOOD DECK W/ ELASTOMERIC/WATERPROOFED FINISH. WOOD FENCE, HEIGHT PER ELEVATION. 9 AD1 4 AD4 32 GARAGE MECHANICAL EXHAUST SHAFT PER MECANICAL 8 9 15 14 11 18 13 5 3 27 8 9 10 7 23 22 14 10 8 9 10 21 12 3 4 16 7 17 11 18 11 18 26 6 5 11 13 23 14 7 15 8 9 103 12 19 TYP. 2 18 3 3 19 1212 17-20 AD1 17-20 AD1 20 6 5 11 18 15 25 1 28 28 28 28 1 1 1 1 1 28 31 TYP. 30 TYP. 29 1 31 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update ED UNIT 2 UNIT 3 (OPP.)UNIT 2UNIT 3 (OPP.) 13 UNIT 2 FLOOR PLAN SHOWN. UNIT 3 FLOOR PLAN IS MIRRORED WHERE OPPOSITE CONDITION OCCURS TYP. 30 1 NOTE: UNIT 2 FLOOR PLAN SHOWN. UNIT 3 FLOOR PLAN IS MIRRORED WHERE OPPOSITE CONDITION OCCURS BC ED UNIT 2 UNIT 3 (OPP.)UNIT 2UNIT 3 (OPP.) 1 13 AD5 13 AD5 13 AD5 13 AD5 UP 18R LIVING ROOM 232 SF LT: 72 SF VT: 48 SF 11'-11 1/2"11'-0"5'-8" 10'-8" 32'-9 1/2" 22'-1 1/2" 4'-2" BATH 1 46 SF 1' - 0 " 32'-9 1/2" C 3 5 4 42" REF DINING ROOM 269 SF LT: 78 SF VT: 40 SF B BEDROOM 1 106 SF LT: 48 SF VT: 24 SF KITCHEN 129 SF LT:14 SF VT: 7 SF DN 14R DW 5 F 3'-6 1/2" EQ.EQ.5'-8" 7 9 3'-2" 7'-0 1/2" 3' - 1 0 " 7' - 4 " 1' - 0 " 2'-0"3'-6"4'-10 1/2" 6'- 1 1 " 3' - 6 " 11 1/2" AIR GAP 1/2" AIR GAP 2' - 0 " 4'-11 1/2" 16 ' - 1 1 / 2 " 30 ' - 0 " 12 ' - 1 0 1 / 2 " D 9'- 0 1 / 2 " 3' - 6 " 30 ' - 0 " 11 ' - 1 1 / 2 " 2' - 6 " 3'- 1 0 " 1'- 0 " 3'-0" 16'-7 1/2" 2" 2" 11" 11" 2%DN ELEC G / M 2%DN 3. 6 % DN DN 18R BEDROOM 3 123 SF LT: 48 SF VT: 24 SF MASTER BEDROOM 213 SF LT: 44 SF VT: 16.5 SF 3' - 6 " BAY WINDOW AREA W.I.C. 42 SF 5'-8"6'-7 1/2"5'-6" 32'-9 1/2" 6'-11 1/2"17'-7 1/2" 9'- 4 1 / 2 " 30 ' - 0 " 12 ' - 7 1 / 2 " 4'-3" 4'-0" W/D 7'-0" 1' - 0 " 1' - 0 " 4'-0" BATH 3 43 SF BATH 2 42 SF 32'-9 1/2" 1' - 6 " G J H M N M N 5 A D G 7 9 9 MASTER BATH 119 SF EQ.EQ.3'-10"3'-6 1/2"3'-2" EQ.EQ.3'-0"3'-3"1'-8 1/2" 7 10 99 7 8 12 5' - 6 " 1' - 6 " 3' - 1 0 " 8' - 9 " 4'-0"1'-4" 3'-11 1/2" 3' - 6 " 8 1/2" AIR GAP 1/2" AIR GAP 5'-0" 3'- 0 " 5'-7 1/2" K 13 ' - 7 1 / 2 " 9'- 0 1 / 2 " 3' - 6 " 30 ' - 0 " 5' - 6 1 / 2 " 3'- 1 0 " 10 ' - 8 1 / 2 " BEDROOM 2 149 SF LT: 52 SF VT: 12 SF 1'- 0 " 5 1'-6" 3' - 1 0 " 11'-9" 1' - 0 " 3'-8 1/2" 2 A5.3 A2.3 TYPE B2 ENLARGED FLOOR PLANS SCALE: 1/4" = 1'-0" ENLARGED 1ST FLOOR PLAN2 NORTH SCALE: 1/4" = 1'-0" ENLARGED 2ND FLOOR PLAN 1 NORTH 2 A5.3 1 A5.2 1 A5.2 2 1 EF EF 2 1 * CONTRACTOR TO FIELD VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB AND SHALL NOTIFY THE ARCHITECT FOR ANY DISCREPANCIES IMMEDIATELY BEFORE COMMENCING ANY WORK. ALL DIMENSIONS ARE TO FACE OF STUD, U.N.O. SEE PLANS AND WALL DETAILS. 1 LINE OF BUILDING/CANOPY ABOVE. 2 FLOORING PER OWNER, TYP. 3 LANDINGS AT DOORS SHALL COMPLY WITH CRC R311.3. 5 LAVATORY PER OWNER'S SPECIFICATIONS. LAVATORY FAUCETS TO HAVE MAXIMUM FLOW RATE OF 1.2 GPM PER CGBC 4.303.1. INSULATION AT ALL PLUMBING WALLS, WHERE OCCURS. 4 PLUMBING HOOK-UPS FOR NEW PLUMBING FIXTURES AND APPLIANCES IN KITCHEN. KITCHEN FAUCET TO HAVE MAXIMUM FLOW RATE OF 1.8 GPM PER CGBC 4.303.1. 6 THIN SET O/ SUBFLOOR. SELECTED BY OWNER.7 9 10 ALL SHOWERS & TUBS SHALL HAVE A PERMANENTLY ACCESSIBLE 12" SQUARE BATHTUB TRAP ACCESS OR USE A NON-SLIP JOINT TRAP 11 8 ALL SHOWERS & TUBS SHALL BE FINISHED BY MATERIALS WHICH ARE NOT ADVERSELY AFFECTED BY MOISTURE TO A MIN. HEIGHT OF 72" ABOVE THE DRAIN INLET. ALL SHOWERS AND TUB-SHOWERS SHALL HAVE EITHER A PRESSURE BALANCE OR A THERMOSTATIC MIXING VALVE. ALL SHOWERHEADS TO HAVE MAXIMUM FLOW RATE OF 1.8 GPM PER CGBC 4.303.1. 13 UPPER & LOWER CABINETS, FINISH PER OWNER, LOWER CABINETS ONLY AT RESTROOMS AND KITCHEN ISLAND. FRAMELESS BEVELED EDGE MIRROR MEDICINE CABINET. 14 15 PROVIDE SHELVES & POLE @ ALL CLOSET W/ 5/8" THK. X 12" D. MDF MELAMINE FINISH. 12 16 1/4" THK. CLEAR TEMP. GLASS, FRAMELESS SHOWER ENCLOSURE W/ CHROME DOOR HANDLE, HINGES & 12" TOWEL BAR. NOTE: CONTRACTOR TO PROVIDE MINIMUM 22" CLR. WIDTH DOOR. WATER CLOSETS (TOILETS) TO USE NO MORE THAN 1.28 GALLONS PER FLUSH PER CGBC 4.303.1. 17 18 19 20 GUARDRAIL/HANDRAIL AT STAIRS AND LANDING. HANDRAIL TO BE LOCATED 34"-36" ABOVE THE NOSE OF EACH TREAD. GUARDRAIL TO BE LOCATED 42" ABOVE THE FINISH FLOOR, TYP. SEE A6.1 FOR STAIR PLANS AND SECTION. NEW COUNTER TOP, SELECT PER OWNER. 21 22 23 STACKED WASHER/DRYER SHALL BE PROVIDED A MIN. 4" Ø SMOOTH, METAL EXHAUST DUCT, SHALL TERMINATE IN AN APPROVED LOCATION OUTSIDE OF THE BUILDING & SHALL HAVE A BACKDRAFT DAMPER. EXHAUST DUCT IS LIMITED TO 14'-0" W/ 2 ELBOWS. THIS SHALL BE REDUCED 2'-0" FOR EVERY ELBOW IN EXCESS OF 2. NOTE: PROVIDE VERTICAL VENT THROUGH THE TOP OF THE ROOF. VENT SHALL BE LESS THAN 14' IN LENGTH. KITCHEN COOKTOP AND HOOD PER OWNER'S SPECIFICATIONS. 24 25 42" H LOW WALL BASEMENT EXHAUST SHAFT 2 AD5 3,4 AD5 10 AD5 26 30" X 30" ATTIC ACCESS ABOVE. FREESTANDING TUB PER OWNER. FLOOR PLAN NOTES 36" REFRIGERATOR, SELECT PER OWNER.27 WALL LEGEND 2X4 WOOD FRAMING PER STRUCT. DWGS. W/ GYP. BD. INTERIOR FINISH. 2X6 WOOD FRAMING PER STRUCT. DWGS. W/ GYP. BD. INTERIOR FINISH. 1 AD1 1-4 AD2 9 AD5 2X6 WOOD FRAMING PER STRUCT. DWGS. W/ GYP. BD. INTERIOR FINISH. EXTERIOR FINISH PER ELEVATIONS, U.N.O. 20 A6.11 AD1 3 AD5 13,14,18 AD4 CANTILEVER CANOPY PREP/VEGETABLE SINK, SELECT PER OWNER. BALCONY GUARDRAIL. 17,18 AD5 20 A3.2 17,18 AD2 1 28 CEMENT, FIBER-CEMENT, FIBERMAT REINFORCED CEMENT, GLASS MAT GYPSUM OR FIBER-REINFORCED GYPSUM BACKERS SHALL BE USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN SHOWER AREAS. 1 31 29 30 LANDSCAPE PER LANDSCAPE DRAWINGS. WOOD DECK W/ ELASTOMERIC/WATERPROOFED FINISH. WOOD FENCE, HEIGHT PER ELEVATION. 9 AD1 4 AD4 32 GARAGE MECHANICAL EXHAUST SHAFT PER MECANICAL TYP. 8 9 15 14 11 18 13 5 3 27 8 9 10 7 23 22 14 10 8 9 10 21 20 12 3 4 16 7 17 11 18 11 18 26 6 5 11 13 23 14 7 15 3 12 19 2 18 3 3 19 12 12 17-20 AD1 17-20 AD1 27 3 6 5 11 18 15 25 1 28 28 28 28 1 1 1 1 8 9 10 1 28 TYP. 30 TYP. 29 1 31 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 32 132 TYP. 301 19 13 AD5 13 AD5 13 AD5 13 AD5 +84 FG VH+12 +12 CWHWCW +12 +12 HW CW GD +12 TV S C PBCH I M E HW CW V T EF HB WP WP HB TO LIGHT BELOW TO LIGHT ABOVE 9'-7" 8'-7" 2' - 0 " TY P . 3'-5"5'-0"5'-0" 2'-6" EQ . EQ . 1'-9" TYP. 1'- 9 " TY P . 2'-11" 3' - 5 1 / 2 " 4'-3"2'-0" 4'- 0 " 3' - 5 " EQ. EQ . EQ . EQ. EQ.EQ. 3,D 333,D 33,D3 3'-0" CW EQ . EQ . CL 3,D3,D 3 33, D 2' - 0 " EQ . EQ . LC 3'-0"3'-0" 3 LC LC 9"9" 1'-0" 1'-6" 1' - 6 " 5' - 6 " 3' - 6 " D D 3,D CW HW CW HW CW V EF W S C T S S S TV TV CWHW V EFW CWHW TV F.A.U. HWCW 3,D TO LIGHT BELOW CW 8'-7" 8'-7" 2'-0" 2'- 0 " TY P . 3'-7 1/2" EQ.EQ. EQ . SLOPE DN 5:12 1' - 0 " SL O P E D N 5: 1 2 SL O P E D N 5: 1 2 SL O P E D N 5: 1 2 2'-0" TYP. SL O P E D N 5: 1 2 2' - 0 " FG CL 2'-0" 9'-1" 9'-1" CL 2' - 0 " 2' - 0 " EQ . 2'-0" TYP.2' - 0 " CL 2' - 0 " 12" EF1 D D D D D D D WP SCALE: 1/4" = 1'-0" 1ST FLOOR REFLECTED CEILING PLAN2 NORTH SCALE: 1/4" = 1'-0" 1 NORTH A2.4 TYPE A REFLECTED CEILING PLANS 2ND FLOOR REFLECTED CEILING PLAN 19 7 14 3 4 TYP. TYP. 13 20 9 TYP.17 2 18 TYP. 19 3 4 TYP. TYP. 7 2 TYP. 17 TYP. 5 TYP. 16 10 12 9 TYP. 13 TYP. TYP. INDOOR VENTILATION CALCULATION PER PROVIDE A CONTINUOUS RUNNININGEXHAUST FAN FOR INDOOR AIR QUALITY. THE VENTILATION VOLUMESHALL BE A MINIMUM OF 1 CFM/100 SQ. FT. OF FLOOR AREA PLUS7.5 CFM/OCCUPANT. THE NUMBER OF OCCUPANTS IS DETERMINED BYTHE NUMBER OF BEDROOMS + 1. TOTAL LIVING SQ. FT. / 100 = NUMBER OF BEDROOMS +1= x 7.5 CFM/OCCUPANT= PROVIDE A CONTINUOUS RUNNING EXHAUST FAN W/ A MINIMUM CFM C.E.C. SECTION 150 (O) 1,335 13.35 3 4 30 43.35 1 1 1 1 1 1 1 1 1 1 1 1 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 1 1 11 14 13 12 1 ALL CEILING HEIGHTS TO BE 10'-1" FOR 1ST FLOOR, 9'-1" FOR 2ND FLOOR, U.N.O. ALL ELEC. OUTLET MAX. DIST. 12'-0" APART. ALL SWITCHES TO BE WHITE COLOR, DECORA FLAT BUTTON. SMOKE DETECTORS MUST RECEIVE THEIR PRIMARY POWER FROM THE BLDG. WIRING & SHALL BE EQUIPPED W/ A BATTERY BACKUP. ALL LIGHT FIXTURES TO BE CENTERED ON ROOM, NICHE, DOOR WAY OR HALLWAY, U.N.O., CONTRACTOR TO VERIFY WITH ARCHITECT. ALL OUTLET TO BE WHITE COLOR SET @ 12" A.F.F. U.N.O. PROVIDE 120/240V SUPPLY FOR STACK DRYER W/ A 30AMP DOUBLE PULL BREAKER (USE 4 WIRE RECEPTICAL W/ GROUND) F.A.U. (PER ENERGY CALCULATIONS) LOCATION IN ATTIC. ALL NEW CIRCUITS SHALL BE AFCI PROTECTED. PROVIDE ARC-FAULT CURRENT INTERRUPTER FOR ALL NEW LIGHTING & RECEPTACLES. ALL RECESSED CEILING LIGHT SHALL BE UL APPROVED, IC UNITS FOR INSULATED SPACE WHERE OCCURS. EXTERIOR LIGHTS SHALL BE HOODED & ARRANGED TO REFLECT AWAY FROM ADJOINING PROPERTIES & STREET. MAX. HT. OF 15'-0" ABOVE GRADE. 2 4 3 6 7 5 10 9 11 8 ALL HOSE BIBBS MUST BE EQUIPPED W/ AN APPROVED NON-REMOVABLE TYPE BACK FLOW PREVENTION DEVICE. SEE 603.4.7 OF THE CALIFORNIA PLUMBING CODE. HEATING & COOLING EQUIPMENT SHALL BE PROVIDED AN ELECTRICAL RECEPTACLE & SWITCH CONTROLLED LIGHTING FIXTURE. THE RECEPTACLE SHALL BE INSTALLED WITHIN 25'-0" OF HEATING, & COOLING EQUIPMENT. THE LIGHTING FIXTURE SHALL BE CONTROLLED BY A SWITCH LOCATED AT THE PASSAGEWAY LEADING TO THE HEATING OR COOLING EQUIPMENT AND SHALL BE PROVIDED AT THE POINT OF ENTRY TO THE ATTIC OR UNDERFLOOR SPACE HOUSING SUCH EQUIPMENT. CEC ARTICLES 210-63 & 210-70(C). ALL NEW A/C SUPPLY AIR GRILL EXTEND FROM WALL, WHERE POSSIBLE. PROVIDE 20-AMP BRANCH CIRCUIT TO SUPPLY THE LAUNDRY RECEPTACLE OUTLET. 15 17 16 TWO SMALL APPLIANCE BRANCH CIRCUITS ARE REQUIRED FOR THE KITCHEN AND ARE LIMITED TO SUPPLYING WALL AND COUNTER SPACE OUTLETS FOR THE KITCHEN, PANTRY, BREAKFAST ROOM, DINING ROOM, OR SIMILAR AREAS. NOTE: THESE CIRCUITS CANNOT SERVE OUTSIDE PLUGS, RANGE HOOD, DISPOSALS, DISHWASHERS OR MICROWAVES - ONLY THE REQUIRED COUNTERTOP/WALL OUTLETS INCLUDING THE REFRIGERATOR. CEC 210-11(c) (1) AND 210-52 (b) 18 PROVIDE 20-AMP CIRCUIT TO SERVE THE REQUIRED BATHROOM OUTLET. THIS CIRCUIT CANNOT SUPPLY ANY OTHER RECEPTACLES, LIGHTS, FANS, ETC. (EXCEPTION-WHERE THE CIRCUIT SUPPLIES A SINGLE BATHROOM, OUTLETS FOR OTHER EQUIPMENT WITHIN THE SAME BATHROOM SHALL BE PERMITTED TO BE SUPPLIED.) CEC 210-11(c) (3) 210-52 WHERE MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE INSTALLED WITHIN AN INDIVIDUAL DWELLING OR SLEEPING UNIT, THE SMOKE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. PER CRC R314.5 19 AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL-BURNING APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. REQUIRED CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH A BATTERY BACK-UP. WHERE MORE THAN ONE CARBON MONOXIDE ALARM IS REQUIRED TO BE INSTALLED WITHIN THE DWELLING UNIT OR WITHIN A SLEEPING UNIT, THE ALARM SHALL BE INTERCONNECTED IN A MANNER THAT ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. PER CRC 315.1.2 AND CBC 420.4.1 20 GARAGE, LAUNDRY, AND UTILITY ROOMS MUST HAVE HIGH EFFICACY LIGHTING W/ VACANCY SENSOR TO CONTROL LIGHTING. 21 PB CHIME FAU 9'-0" CW FG W S EF VH 3 TELEPHONE OUTLET. DUPLEX ELECTRICAL A.F.C.I. OUTLET WALL MOUNTED @ 12" A.F.F. U.N.O. 6" DIA. RECESSED CAN LIGHT (HIGH EFFICACY, CONTROLLED BY DIMMER). DUPLEX EXTERIOR G.F.C.I. ELECTRICAL OUTLET W/ WATER PROOF COVER. DOOR CHIME. FINISH CEILING HEIGHT PUSH BUTTON. 12"X48" SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE DOUBLE TUBE (MUST BE HIGH EFFICACY OR CONTROLLED BY A VACANCY SENSOR). SMOKE DETECTOR/ALARM WALL MOUNTED HARDWIRED WITH BATTERY BACK-UP INTERCONNECTED. PROVIDE APPROVED 6" DIA. WATERPROOF RECESSED CAN LIGHT FOR WET AREA (HIGH EFFICACY). COLD WATER. GAS. KITCHEN VENTILATION HOOD, TO HAVE MIN. VENTILATION OF 100 CFM. VENTILATION DUCT SHALL BE OF METL & SHALL HAVE SMOOTH INTERIOR SURFACES. DUCT SHALL TERMINATE OUTSIDE OF THE BUILDING IN AN APPROVED LOCATION AND SHALL HAVE DACKDRAFT DAMPERS. EXHAUST FAN W/ 50 CFM MIN. PER TABLE 4-4 CMC. INCLUDING BUILT-IN HIGH EFFICACY LIGHT FIXTURE AND HUMIDISTAT CONTROL. NOTE: CONTRACTOR TO PROVIDE (2) SEPARATE SWITCHES WHERE (1) STANDARD SWITCH IS FOR THE FAN AND (1) DIMMER SWITCH IS FOR THE LIGHT. LIGHT FIXTURE CEILING MOUNTED (HIGH EFFICACY). LIGHT FIXTURE WALL MOUNTED (HIGH EFFICACY). LIGHT SWITCH. A/C RETURN AIR GRILL (FULLY BLOCK OPENING AS NECESSARY) F.A.U. MOUNTED IN ATTIC MOUNTED ON PLATFORM (FULLY BLOCK ALL EDGE AS NECESSARY) HATCHED AREA DENOTES NEW DROPPED SOFFIT BELOW F.J./C.J. FRAMING (SEE PLAN FOR EXACT HEIGHT). HB HOSE BIBB. TWO WAY LIGHT SWITCH. 30X30 ROOF ATTIC ACCESS (FULLY BLOCK OPENING AS NECESSARY) CARBON MONOXIDE DETECTOR/ALARM WALL MOUNTED HARDWIRED WITH BATTERY BACK-UP INTERCONNECTED. C HW HOT WATER. GARBAGE DISPOSAL.GD P HIGH EFFICACY CLOSET LIGHT WITH PROTECTIVE COVER IN-LINE WHOLE-HOUSE REMOTE MOUNTED EXHAUST FAN 'FANTECH' MODEL FR-150 SHALL DELIVER MIN. 85 CFM @ .20" SP SONE=0.47. ELECTRICAL: 120V/1Ø/60HZ, 72.1 WATTS. WEIGHT = 8 LBS PROVIDE WALL JACK AND BACKDRAFT DAMPER. UNIT SHALL BE OPERATED CONTINUOUSLY & ELECTRICALLY INTERLOCKED WITH ON-OFF SWITCH LABELED WITH "OPERATE WHEN THE HOUSE IS IN USE." EXHAUST FAN TO PROVIDE WHOLE HOUSE INDOOR AIR QUALITY VENTILATION PER 2013 CALIFORNIA ENERGY CODE SECTION 150(O) AND ASHRAE STANDARD 62.2-2013, AND DUCTING SHALL BE SIZED ACCORDING TO ASHRAE STANDARD 62.2 TABLE 7.1. EF1 DATA OUTLET. CEILING PLAN NOTESCEILING LEGEND WP DUPLEX EXTERIOR G.F.C.I. ELECTRICAL OUTLET @ 42" A.F.F. U.N.O. UNDER CABINET LED STRIP LIGHTING. LINE OF ROOF ABOVE PENDANT LIGHT FIXTURE CEILING MOUNTED (HIGH EFFICACY). 6 AD5 V LIGHT SWITCH W/ VACANCY SENSOR A/C DISCONNECT T THERMOSTAT W/ DEMAND RESPONSE CONTROLS COVE LED STRIP LIGHTING AT SOFFIT. 1 1 D LIGHT SWITCH W/ DIMMER 1 1 1 3 TV CHIME S C T TV S PB HW CW GD +84 FG VH +12 HW CW+12 W EF HW CW CW CW HW CW +12 3 3 +12 8'-7" 9'-1" TO LIGHT ABOVE TO LIGHT BELOW TV V9'-1" EQ . EQ . 2' - 0 " 33 5'-0"5'-0" 5'-0" 3' - 9 " 3' - 9 " 3' - 9 " EQ . EQ . 9'-0" 2' - 6 " 1' - 0 " EQ. 333,D 3' - 0 " TY P . 2'-6" CL 7'- 4 " EQ. 2' - 0 " CL EQ . EQ . 2'-0" 8'-3" EQ.EQ. 3,D 3,D 2' - 0 " 2' - 0 " 2'-0" 2'-0" 3 33 33,D CL 3'- 2 1 / 2 " 4' - 6 " EQ . EQ . 2'-1" 2'-1" 1' - 0 " 6" 3,D 3,D CL 1' - 0 " 6" WP HB WP HB 3,D3,D D D D D F.A.U. TV TV TV HW CW CW HW CW CW W CW HW HW CW W CW HW EF EF S S S S C T3,D 3,D3,D 8'-7" 8'-7" EQ.EQ. EQ . EQ . EQ . EQ . HW CW CW CW W CW HW W CW HW EF V 10'-1" 9'-7" EQ . EQ . 2'-0" 3'- 0 " SL O P E D N 5: 1 2 SL O P E D N 5: 1 2 SL O P E D N 5: 1 2 2' - 0 " VV EQ . EQ .2'-0"2'-0" TO LIGHT BELOW CW HW HWEQ . 8'-7" 2'- 0 " D 2'-0" 2'-0" EQ . V CL 2'- 0 " FG CL 2'- 0 " 2'- 0 " CL 3,D 3,D 12 " 12 " 12 " 12 " EQ . EQ . EQ.EQ. 6"3 EQ.3 EQ.3 EQ.12" 8'-3" 9'-1" EF V EF1 D D D D D D WP A2.5 TYPE B REFLECTED CEILING PLANS SCALE: 1/4" = 1'-0" 2 NORTH SCALE: 1/4" = 1'-0" 1 NORTH 1ST FLOOR REFLECTED CEILING PLAN2ND FLOOR REFLECTED CEILING PLANNOTE: UNIT 2 FLOOR PLAN SHOWN. UNIT 3 FLOOR PLAN IS MIRRORED. NOTE: UNIT 2 FLOOR PLAN SHOWN. UNIT 3 FLOOR PLAN IS MIRRORED. 14 13 12 1 ALL CEILING HEIGHTS TO BE 10'-1" FOR 1ST FLOOR, 9'-1" FOR 2ND FLOOR, U.N.O. ALL ELEC. OUTLET MAX. DIST. 12'-0" APART. ALL SWITCHES TO BE WHITE COLOR, DECORA FLAT BUTTON. SMOKE DETECTORS MUST RECEIVE THEIR PRIMARY POWER FROM THE BLDG. WIRING & SHALL BE EQUIPPED W/ A BATTERY BACKUP. ALL LIGHT FIXTURES TO BE CENTERED ON ROOM, NICHE, DOOR WAY OR HALLWAY, U.N.O., CONTRACTOR TO VERIFY WITH ARCHITECT. ALL OUTLET TO BE WHITE COLOR SET @ 12" A.F.F. U.N.O. PROVIDE 120/240V SUPPLY FOR STACK DRYER W/ A 30AMP DOUBLE PULL BREAKER (USE 4 WIRE RECEPTICAL W/ GROUND) F.A.U. (PER ENERGY CALCULATIONS) LOCATION IN ATTIC. ALL NEW CIRCUITS SHALL BE AFCI PROTECTED. PROVIDE ARC-FAULT CURRENT INTERRUPTER FOR ALL NEW LIGHTING & RECEPTACLES. ALL RECESSED CEILING LIGHT SHALL BE UL APPROVED, IC UNITS FOR INSULATED SPACE WHERE OCCURS. EXTERIOR LIGHTS SHALL BE HOODED & ARRANGED TO REFLECT AWAY FROM ADJOINING PROPERTIES & STREET. MAX. HT. OF 15'-0" ABOVE GRADE. 2 4 3 6 7 5 10 9 11 8 ALL HOSE BIBBS MUST BE EQUIPPED W/ AN APPROVED NON-REMOVABLE TYPE BACK FLOW PREVENTION DEVICE. SEE 603.4.7 OF THE CALIFORNIA PLUMBING CODE. HEATING & COOLING EQUIPMENT SHALL BE PROVIDED AN ELECTRICAL RECEPTACLE & SWITCH CONTROLLED LIGHTING FIXTURE. THE RECEPTACLE SHALL BE INSTALLED WITHIN 25'-0" OF HEATING, & COOLING EQUIPMENT. THE LIGHTING FIXTURE SHALL BE CONTROLLED BY A SWITCH LOCATED AT THE PASSAGEWAY LEADING TO THE HEATING OR COOLING EQUIPMENT AND SHALL BE PROVIDED AT THE POINT OF ENTRY TO THE ATTIC OR UNDERFLOOR SPACE HOUSING SUCH EQUIPMENT. CEC ARTICLES 210-63 & 210-70(C). ALL NEW A/C SUPPLY AIR GRILL EXTEND FROM WALL, WHERE POSSIBLE. PROVIDE 20-AMP BRANCH CIRCUIT TO SUPPLY THE LAUNDRY RECEPTACLE OUTLET. 15 17 16 TWO SMALL APPLIANCE BRANCH CIRCUITS ARE REQUIRED FOR THE KITCHEN AND ARE LIMITED TO SUPPLYING WALL AND COUNTER SPACE OUTLETS FOR THE KITCHEN, PANTRY, BREAKFAST ROOM, DINING ROOM, OR SIMILAR AREAS. NOTE: THESE CIRCUITS CANNOT SERVE OUTSIDE PLUGS, RANGE HOOD, DISPOSALS, DISHWASHERS OR MICROWAVES - ONLY THE REQUIRED COUNTERTOP/WALL OUTLETS INCLUDING THE REFRIGERATOR. CEC 210-11(c) (1) AND 210-52 (b) 18 PROVIDE 20-AMP CIRCUIT TO SERVE THE REQUIRED BATHROOM OUTLET. THIS CIRCUIT CANNOT SUPPLY ANY OTHER RECEPTACLES, LIGHTS, FANS, ETC. (EXCEPTION-WHERE THE CIRCUIT SUPPLIES A SINGLE BATHROOM, OUTLETS FOR OTHER EQUIPMENT WITHIN THE SAME BATHROOM SHALL BE PERMITTED TO BE SUPPLIED.) CEC 210-11(c) (3) 210-52 WHERE MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE INSTALLED WITHIN AN INDIVIDUAL DWELLING OR SLEEPING UNIT, THE SMOKE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. PER CRC R314.5 19 AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL-BURNING APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. REQUIRED CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH A BATTERY BACK-UP. WHERE MORE THAN ONE CARBON MONOXIDE ALARM IS REQUIRED TO BE INSTALLED WITHIN THE DWELLING UNIT OR WITHIN A SLEEPING UNIT, THE ALARM SHALL BE INTERCONNECTED IN A MANNER THAT ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. PER CRC 315.1.2 AND CBC 420.4.1 20 GARAGE, LAUNDRY, AND UTILITY ROOMS MUST HAVE HIGH EFFICACY LIGHTING W/ VACANCY SENSOR TO CONTROL LIGHTING. 21 PB CHIME FAU 9'-0" CW FG W S EF VH 3 TELEPHONE OUTLET. DUPLEX ELECTRICAL A.F.C.I. OUTLET WALL MOUNTED @ 12" A.F.F. U.N.O. 6" DIA. RECESSED CAN LIGHT (HIGH EFFICACY, CONTROLLED BY DIMMER). DUPLEX EXTERIOR G.F.C.I. ELECTRICAL OUTLET W/ WATER PROOF COVER. DOOR CHIME. FINISH CEILING HEIGHT PUSH BUTTON. 12"X48" SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE DOUBLE TUBE (MUST BE HIGH EFFICACY OR CONTROLLED BY A VACANCY SENSOR). SMOKE DETECTOR/ALARM WALL MOUNTED HARDWIRED WITH BATTERY BACK-UP INTERCONNECTED. PROVIDE APPROVED 6" DIA. WATERPROOF RECESSED CAN LIGHT FOR WET AREA (HIGH EFFICACY). COLD WATER. GAS. KITCHEN VENTILATION HOOD, TO HAVE MIN. VENTILATION OF 100 CFM. VENTILATION DUCT SHALL BE OF METL & SHALL HAVE SMOOTH INTERIOR SURFACES. DUCT SHALL TERMINATE OUTSIDE OF THE BUILDING IN AN APPROVED LOCATION AND SHALL HAVE DACKDRAFT DAMPERS. EXHAUST FAN W/ 50 CFM MIN. PER TABLE 4-4 CMC. INCLUDING BUILT-IN HIGH EFFICACY LIGHT FIXTURE AND HUMIDISTAT CONTROL. NOTE: CONTRACTOR TO PROVIDE (2) SEPARATE SWITCHES WHERE (1) STANDARD SWITCH IS FOR THE FAN AND (1) DIMMER SWITCH IS FOR THE LIGHT. LIGHT FIXTURE CEILING MOUNTED (HIGH EFFICACY). LIGHT FIXTURE WALL MOUNTED (HIGH EFFICACY). LIGHT SWITCH. A/C RETURN AIR GRILL (FULLY BLOCK OPENING AS NECESSARY) F.A.U. MOUNTED IN ATTIC MOUNTED ON PLATFORM (FULLY BLOCK ALL EDGE AS NECESSARY) HATCHED AREA DENOTES NEW DROPPED SOFFIT BELOW F.J./C.J. FRAMING (SEE PLAN FOR EXACT HEIGHT). HB HOSE BIBB. TWO WAY LIGHT SWITCH. 30X30 ROOF ATTIC ACCESS (FULLY BLOCK OPENING AS NECESSARY) CARBON MONOXIDE DETECTOR/ALARM WALL MOUNTED HARDWIRED WITH BATTERY BACK-UP INTERCONNECTED. C HW HOT WATER. GARBAGE DISPOSAL.GD P HIGH EFFICACY CLOSET LIGHT WITH PROTECTIVE COVER IN-LINE WHOLE-HOUSE REMOTE MOUNTED EXHAUST FAN 'FANTECH' MODEL FR-150 SHALL DELIVER MIN. 85 CFM @ .20" SP SONE=0.47. ELECTRICAL: 120V/1Ø/60HZ, 72.1 WATTS. WEIGHT = 8 LBS PROVIDE WALL JACK AND BACKDRAFT DAMPER. UNIT SHALL BE OPERATED CONTINUOUSLY & ELECTRICALLY INTERLOCKED WITH ON-OFF SWITCH LABELED WITH "OPERATE WHEN THE HOUSE IS IN USE." EXHAUST FAN TO PROVIDE WHOLE HOUSE INDOOR AIR QUALITY VENTILATION PER 2013 CALIFORNIA ENERGY CODE SECTION 150(O) AND ASHRAE STANDARD 62.2-2013, AND DUCTING SHALL BE SIZED ACCORDING TO ASHRAE STANDARD 62.2 TABLE 7.1. EF1 DATA OUTLET. CEILING PLAN NOTESCEILING LEGEND WP DUPLEX EXTERIOR G.F.C.I. ELECTRICAL OUTLET @ 42" A.F.F. U.N.O. UNDER CABINET LED STRIP LIGHTING. LINE OF ROOF ABOVE PENDANT LIGHT FIXTURE CEILING MOUNTED (HIGH EFFICACY). 6 AD5 V LIGHT SWITCH W/ VACANCY SENSOR A/C DISCONNECT T THERMOSTAT W/ DEMAND RESPONSE CONTROLS COVE LED STRIP LIGHTING AT SOFFIT. 1 1 D LIGHT SWITCH W/ DIMMER 1 1 1 3 17 TYP. 16 8 TYP.9 TYP. 7 TYP. 191012 5 43TYP.2 TYP. 5 TYP.8 TYP.14 19 7 TYP. 9 TYP. 20 18 3 4 TYP. 13 TYP.2 TYP. 1 INDOOR VENTILATION CALCULATION PER PROVIDE A CONTINUOUS RUNNININGEXHAUST FAN FOR INDOOR AIR QUALITY. THE VENTILATION VOLUMESHALL BE A MINIMUM OF 1 CFM/100 SQ. FT. OF FLOOR AREA PLUS7.5 CFM/OCCUPANT. THE NUMBER OF OCCUPANTS IS DETERMINED BYTHE NUMBER OF BEDROOMS + 1. TOTAL LIVING SQ. FT. / 100 = NUMBER OF BEDROOMS +1= x 7.5 CFM/OCCUPANT= PROVIDE A CONTINUOUS RUNNING EXHAUST FAN W/ A MINIMUM CFM C.E.C. SECTION 150 (O) 1,922 19.22 4 5 37.5 56.72 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 11 13 TV S T TV S W 8'-7" 9'-1" TO LIGHT ABOVE TO LIGHT BELOW 4' - 6 " TV 9'-1" EQ . EQ . 4' - 6 " 2' - 0 " 4'-7" 3' - 9 " 3' - 9 " 3' - 9 " EQ . EQ . EQ . EQ . 9'-1" 2' - 6 " 1' - 0 " EQ. 3' - 0 " TY P . 2'-6" 7'- 4 " EQ. 2' - 0 " CL EQ . EQ . 2'-0"EQ.EQ. 2' - 0 " 2' - 0 " 2'-0" 2'-1"2'-0" CL 3'- 2 1 / 2 " 7'-6"4'-2" 4'-7"4'-7"CL CL 2'-1" 1' - 0 " 6" CL 1' - 0 " 6" TO TIMER, SEE 2/A1.1 CHIME C PB HW CW GD +84 FG VH +12 HW CW+12 EF HW CW CW CW HW CW +12 3 3 +12 V 33 333,D 3,D 3,D 3 33 33,D 3,D 3,D WP HB WP HB 3,D3,D D D D D F.A.U. TV TV TV W WS S S S T 8'-7" 8'-7" EQ.EQ. EQ . EQ . EQ . EQ . W W 10'-1" 9'-7" EQ . EQ . 2'-0" 3'- 0 " SL O P E D N 5: 1 2 SL O P E D N 5: 1 2 SL O P E D N 5: 1 2 2' - 0 " EQ . EQ .2'-0"2'-0" TO LIGHT BELOW 8'-7" 2'- 0 " 2'-0"2'-0" CL 2'- 0 " CL 2' - 0 " 2' - 0 " CL 3 EQ.3 EQ.3 EQ. 9'-1" 12 " 12 " 6" 12" EQ . EQ . 12 " 12 " EQ . EQ . EQ.EQ. 6" 8'-3" HW CW CW HW CW CW CW HW HW CW CW HW EF EF C 3,D 3,D3,D HW CW CW CW CW HW CW HW EF V VV CW HW HW D V FG 3,D 3,D EF V D D D D D D A2.6 TYPE B2 REFLECTED CEILING PLANS SCALE: 1/4" = 1'-0" 1ST FLOOR REFLECTED CEILING PLAN2 NORTH SCALE: 1/4" = 1'-0" 2ND FLOOR REFLECTED CEILING PLAN 1 NORTH 17 TYP. 16 8 TYP.9 TYP. 7 TYP. 191012 5 TYP.8 TYP.14 19 7 TYP. 9TYP. 20 18 3 4 TYP. 13 TYP.2 5 43TYP.2 TYP.TYP. 1 INDOOR VENTILATION CALCULATION PER PROVIDE A CONTINUOUS RUNNININGEXHAUST FAN FOR INDOOR AIR QUALITY. THE VENTILATION VOLUMESHALL BE A MINIMUM OF 1 CFM/100 SQ. FT. OF FLOOR AREA PLUS7.5 CFM/OCCUPANT. THE NUMBER OF OCCUPANTS IS DETERMINED BYTHE NUMBER OF BEDROOMS + 1. TOTAL LIVING SQ. FT. / 100 = NUMBER OF BEDROOMS +1= x 7.5 CFM/OCCUPANT= PROVIDE A CONTINUOUS RUNNING EXHAUST FAN W/ A MINIMUM CFM C.E.C. SECTION 150 (O) 1,939 19.39 4 5 37.5 56.89 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 14 13 12 1 ALL CEILING HEIGHTS TO BE 10'-1" FOR 1ST FLOOR, 9'-1" FOR 2ND FLOOR, U.N.O. ALL ELEC. OUTLET MAX. DIST. 12'-0" APART. ALL SWITCHES TO BE WHITE COLOR, DECORA FLAT BUTTON. SMOKE DETECTORS MUST RECEIVE THEIR PRIMARY POWER FROM THE BLDG. WIRING & SHALL BE EQUIPPED W/ A BATTERY BACKUP. ALL LIGHT FIXTURES TO BE CENTERED ON ROOM, NICHE, DOOR WAY OR HALLWAY, U.N.O., CONTRACTOR TO VERIFY WITH ARCHITECT. ALL OUTLET TO BE WHITE COLOR SET @ 12" A.F.F. U.N.O. PROVIDE 120/240V SUPPLY FOR STACK DRYER W/ A 30AMP DOUBLE PULL BREAKER (USE 4 WIRE RECEPTICAL W/ GROUND) F.A.U. (PER ENERGY CALCULATIONS) LOCATION IN ATTIC. ALL NEW CIRCUITS SHALL BE AFCI PROTECTED. PROVIDE ARC-FAULT CURRENT INTERRUPTER FOR ALL NEW LIGHTING & RECEPTACLES. ALL RECESSED CEILING LIGHT SHALL BE UL APPROVED, IC UNITS FOR INSULATED SPACE WHERE OCCURS. EXTERIOR LIGHTS SHALL BE HOODED & ARRANGED TO REFLECT AWAY FROM ADJOINING PROPERTIES & STREET. MAX. HT. OF 15'-0" ABOVE GRADE. 2 4 3 6 7 5 10 9 11 8 ALL HOSE BIBBS MUST BE EQUIPPED W/ AN APPROVED NON-REMOVABLE TYPE BACK FLOW PREVENTION DEVICE. SEE 603.4.7 OF THE CALIFORNIA PLUMBING CODE. HEATING & COOLING EQUIPMENT SHALL BE PROVIDED AN ELECTRICAL RECEPTACLE & SWITCH CONTROLLED LIGHTING FIXTURE. THE RECEPTACLE SHALL BE INSTALLED WITHIN 25'-0" OF HEATING, & COOLING EQUIPMENT. THE LIGHTING FIXTURE SHALL BE CONTROLLED BY A SWITCH LOCATED AT THE PASSAGEWAY LEADING TO THE HEATING OR COOLING EQUIPMENT AND SHALL BE PROVIDED AT THE POINT OF ENTRY TO THE ATTIC OR UNDERFLOOR SPACE HOUSING SUCH EQUIPMENT. CEC ARTICLES 210-63 & 210-70(C). ALL NEW A/C SUPPLY AIR GRILL EXTEND FROM WALL, WHERE POSSIBLE. PROVIDE 20-AMP BRANCH CIRCUIT TO SUPPLY THE LAUNDRY RECEPTACLE OUTLET. 15 17 16 TWO SMALL APPLIANCE BRANCH CIRCUITS ARE REQUIRED FOR THE KITCHEN AND ARE LIMITED TO SUPPLYING WALL AND COUNTER SPACE OUTLETS FOR THE KITCHEN, PANTRY, BREAKFAST ROOM, DINING ROOM, OR SIMILAR AREAS. NOTE: THESE CIRCUITS CANNOT SERVE OUTSIDE PLUGS, RANGE HOOD, DISPOSALS, DISHWASHERS OR MICROWAVES - ONLY THE REQUIRED COUNTERTOP/WALL OUTLETS INCLUDING THE REFRIGERATOR. CEC 210-11(c) (1) AND 210-52 (b) 18 PROVIDE 20-AMP CIRCUIT TO SERVE THE REQUIRED BATHROOM OUTLET. THIS CIRCUIT CANNOT SUPPLY ANY OTHER RECEPTACLES, LIGHTS, FANS, ETC. (EXCEPTION-WHERE THE CIRCUIT SUPPLIES A SINGLE BATHROOM, OUTLETS FOR OTHER EQUIPMENT WITHIN THE SAME BATHROOM SHALL BE PERMITTED TO BE SUPPLIED.) CEC 210-11(c) (3) 210-52 WHERE MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE INSTALLED WITHIN AN INDIVIDUAL DWELLING OR SLEEPING UNIT, THE SMOKE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. PER CRC R314.5 19 AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL-BURNING APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. REQUIRED CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH A BATTERY BACK-UP. WHERE MORE THAN ONE CARBON MONOXIDE ALARM IS REQUIRED TO BE INSTALLED WITHIN THE DWELLING UNIT OR WITHIN A SLEEPING UNIT, THE ALARM SHALL BE INTERCONNECTED IN A MANNER THAT ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. PER CRC 315.1.2 AND CBC 420.4.1 20 GARAGE, LAUNDRY, AND UTILITY ROOMS MUST HAVE HIGH EFFICACY LIGHTING W/ VACANCY SENSOR TO CONTROL LIGHTING. 21 PB CHIME FAU 9'-0" CW FG W S EF VH 3 TELEPHONE OUTLET. DUPLEX ELECTRICAL A.F.C.I. OUTLET WALL MOUNTED @ 12" A.F.F. U.N.O. 6" DIA. RECESSED CAN LIGHT (HIGH EFFICACY, CONTROLLED BY DIMMER). DUPLEX EXTERIOR G.F.C.I. ELECTRICAL OUTLET W/ WATER PROOF COVER. DOOR CHIME. FINISH CEILING HEIGHT PUSH BUTTON. 12"X48" SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE DOUBLE TUBE (MUST BE HIGH EFFICACY OR CONTROLLED BY A VACANCY SENSOR). SMOKE DETECTOR/ALARM WALL MOUNTED HARDWIRED WITH BATTERY BACK-UP INTERCONNECTED. PROVIDE APPROVED 6" DIA. WATERPROOF RECESSED CAN LIGHT FOR WET AREA (HIGH EFFICACY). COLD WATER. GAS. KITCHEN VENTILATION HOOD, TO HAVE MIN. VENTILATION OF 100 CFM. VENTILATION DUCT SHALL BE OF METL & SHALL HAVE SMOOTH INTERIOR SURFACES. DUCT SHALL TERMINATE OUTSIDE OF THE BUILDING IN AN APPROVED LOCATION AND SHALL HAVE DACKDRAFT DAMPERS. EXHAUST FAN W/ 50 CFM MIN. PER TABLE 4-4 CMC. INCLUDING BUILT-IN HIGH EFFICACY LIGHT FIXTURE AND HUMIDISTAT CONTROL. NOTE: CONTRACTOR TO PROVIDE (2) SEPARATE SWITCHES WHERE (1) STANDARD SWITCH IS FOR THE FAN AND (1) DIMMER SWITCH IS FOR THE LIGHT. LIGHT FIXTURE CEILING MOUNTED (HIGH EFFICACY). LIGHT FIXTURE WALL MOUNTED (HIGH EFFICACY). LIGHT SWITCH. A/C RETURN AIR GRILL (FULLY BLOCK OPENING AS NECESSARY) F.A.U. MOUNTED IN ATTIC MOUNTED ON PLATFORM (FULLY BLOCK ALL EDGE AS NECESSARY) HATCHED AREA DENOTES NEW DROPPED SOFFIT BELOW F.J./C.J. FRAMING (SEE PLAN FOR EXACT HEIGHT). HB HOSE BIBB. TWO WAY LIGHT SWITCH. 30X30 ROOF ATTIC ACCESS (FULLY BLOCK OPENING AS NECESSARY) CARBON MONOXIDE DETECTOR/ALARM WALL MOUNTED HARDWIRED WITH BATTERY BACK-UP INTERCONNECTED. C HW HOT WATER. GARBAGE DISPOSAL.GD P HIGH EFFICACY CLOSET LIGHT WITH PROTECTIVE COVER IN-LINE WHOLE-HOUSE REMOTE MOUNTED EXHAUST FAN 'FANTECH' MODEL FR-150 SHALL DELIVER MIN. 85 CFM @ .20" SP SONE=0.47. ELECTRICAL: 120V/1Ø/60HZ, 72.1 WATTS. WEIGHT = 8 LBS PROVIDE WALL JACK AND BACKDRAFT DAMPER. UNIT SHALL BE OPERATED CONTINUOUSLY & ELECTRICALLY INTERLOCKED WITH ON-OFF SWITCH LABELED WITH "OPERATE WHEN THE HOUSE IS IN USE." EXHAUST FAN TO PROVIDE WHOLE HOUSE INDOOR AIR QUALITY VENTILATION PER 2013 CALIFORNIA ENERGY CODE SECTION 150(O) AND ASHRAE STANDARD 62.2-2013, AND DUCTING SHALL BE SIZED ACCORDING TO ASHRAE STANDARD 62.2 TABLE 7.1. EF1 DATA OUTLET. CEILING PLAN NOTESCEILING LEGEND WP DUPLEX EXTERIOR G.F.C.I. ELECTRICAL OUTLET @ 42" A.F.F. U.N.O. UNDER CABINET LED STRIP LIGHTING. LINE OF ROOF ABOVE PENDANT LIGHT FIXTURE CEILING MOUNTED (HIGH EFFICACY). 6 AD5 V LIGHT SWITCH W/ VACANCY SENSOR A/C DISCONNECT T THERMOSTAT W/ DEMAND RESPONSE CONTROLS COVE LED STRIP LIGHTING AT SOFFIT. 1 1 D LIGHT SWITCH W/ DIMMER 1 1 1 3 3 : 12 3 : 12 5 : 12 5 : 12 5 : 12 5 : 1 2 3 : 12 5 : 12 UNIT 2 ATTIC AREA 'C' 541 SF UNIT 1 ATTIC AREA 'A' 287 SF ATTIC AREA 'B' 57 SF RIDGE RIDGEF.A.U. VAULTED CEILING AREA VAULTED CEILING AREA VAULTED CEILING AREA VAULTED CEILING AREA VAULTED CEILING AREA VAULTED CEILING AREA F.A.U. 3 : 12 5 : 12 3 : 12 5 : 12 3 : 12 3 : 12 3 : 12 5 : 12 5 : 12 3 : 12 UNIT 4 ATTIC AREA 'C' 541 SF UNIT 3 ATTIC AREA 'C' 541 SF ATTIC AREA 'B' 57 SF ATTIC AREA 'B' 57 SF RIDGERIDGEF.A.U.F.A.U. VAULTED CEILING AREA VAULTED CEILING AREAVAULTED CEILING AREA VAULTED CEILING AREA VAULTED CEILING AREA VAULTED CEILING AREA SCALE: 1/8" = 1'-0" BUILDING 1 ROOF PLAN 1 NORTH AB 4 3 2 5 6 5" BOX STYLE RAIN GUTTER & 3" DOWNSPOUT, PAINTED. COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN. (SEE ELEVATION FOR DOWNSPOUT LOCATIONS) 'OWENS CORNING' ASPHALT SHINGLE TILE (ICC-ES AC438) COLOR: MOUNTAINSIDE (CRRC 0890-0016) 1 ROOF ASSEMBLIES SHALL BE INSTALLED IN ACCORDANCE TO THE PROVISIONS OF CHAPTER 9 OF THE RESIDENTIAL CODE AND SHALL BE AN ICC-ES OR UL LISTED CLASS 'A' FIRE-RESISTIVE ROOF ASSEMBLY COMPLYING WITH ASTM E108 OR UL 790. 6 A3.2 O'HAGIN TAPERED LOW-PROFILE VENT, PRIMED AND PAINTED W/ TWO COATS. COLOR: MATCH UNIT ROOFING COLOR ROOF PLAN NOTES SCALE: 1/8" = 1'-0" BUILDING 2 ROOF PLAN 2 NORTH C 2 1 DEF 2 1 UNITS 2, 3, AND 4 ROOF ATTIC VENTILATION CALCULATIONS UNIT 1 ROOF ATTIC VENTILATION CALCULATIONS A3.1 ROOF PLANS TYP. 11 A3.2 F.A.U LOCATION BELOW 10 A3.2 PROVIDE B-VENT AS REQUIRED.15 A3.2 7 30" X 30" ATTIC ACCESS BELOW. 8 DRAFTSTOP SHEAR WALL IN UPPER ATTIC SPACE. SEE STRUCTURAL FOR ROOF FRAMING PLAN AND DRAFTSTOP / SHEAR WALL LOCATIONS. SEE STRUCTURAL SHEETS FOR INDIVIDUAL SHEAR WALL DETAILS. PER CRC SEC. R806 ATTIC AREA 'A' = 287 sq. ft. VENT CALCULATION = 287 / 300 = 0.96 sq. ft = 138 sq. in. (1) "LOW" 'O' HAGIN' LOW-PROFILE VENT @ 72 sq. in. ea.= 72 sq. in. (1) "HIGH" 'O' HAGIN' LOW-PROFILE VENT @ 72 sq. in. ea.= 72 sq. in. TOTAL NET FREE VENTING AREA = 144 sq. in. "HIGH" VENTILATION %= 72 sq. in./144 sq. in. = 50.00% "LOW" VENTILATION %= 72 sq. in./144 sq. in.= 50.00% PER CRC SEC. R806 ATTIC AREA 'B' = 57 sq. ft. VENT CALCULATION = 50 / 150 = 0.38 sq. ft = 55 sq. in. (1) 'O' HAGIN' LOW-PROFILE VENT @ 72 sq. in. ea. = 72 sq. in. ATTIC AREA 'C' = 541 sq. ft. VENT CALCULATION = 541 / 300 = 1.81 sq. ft = 260 sq. in. (2) "LOW" 'O' HAGIN' LOW-PROFILE VENT @ 72 sq. in. ea.= 144 sq. in. (2) "HIGH" 'O' HAGIN' LOW-PROFILE VENT @ 72 sq. in. ea.= 144 sq. in. TOTAL NET FREE VENTING AREA = 288 sq. in. "HIGH" VENTILATION %= 144 sq. in./288 sq. in. = 50.00% "LOW" VENTILATION %= 144 sq. in./288 sq. in.= 50.00% 8 4 1 2 3TYP.4 5 4 8 4 TYP.3 1 2 TYP. 7 5 6 5 7 5 7 4 44 4 4 A3.2 3 A3.2 4 A3.2 3 A3.2 4 A3.2 3 A3.2 4 A3.2 4 A3.2 4 A3.2 3 A3.2 4 A3.2 7 A3.2 3 A3.2 4 A3.2 7 A3.2 8 A3.2 4 A3.2 7 A3.2 12 A3.2 12 A3.2 13 A3.2 17 A3.2 TYP. 17 A3.2 TYP. 14,17 A3.2 TYP. 14,17 A3.2TYP. 14,17 A3.2TYP. 1 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update ROOF NOTES 1. PROVIDE PLUMBING VENTS AS REQUIREDBY CHAPER 9 OF THE CPC, SEE DETAIL 16/A3.2 BELOW 11 A3.2 ABOVE 9 A3.2 7 A3.2 9 A3.2 14,17 A3.2TYP. 14,17 A3.2 TYP. 14,17 A3.2TYP. 14,17 A3.2TYP. 17 A3.2 14,17 A3.2 14,17 A3.2 ASPHALT SHINGLE TILE ROOFING MATERIAL O/ W.P. PAPER O/ PLYWD. SHEATHING O/ 2X ROOF FRAMING PER STRUCT. 12 5 EXT. PLASTER O/ W.P. PAPER O/ PLYWD. SHEATHING O/ 2X FRAMING PER STRUCT. BATT INSULATION PER ENERGY CALCULATIONS. 5" BOX STYLE RAIN GUTTER & 3" DOWNSPOUT, PAINTED. 2X BLOCKING PER STRUCT. 2X RAFTER TAILS, 16" O.C. 2X FASCIA, PAINTED 2'-0" EAVE OVERHANG TYPICAL ROOF EAVE (VAULTED CEILING) 1 1/2" = 1'-0" O'HAGIN'S TAPERED, LOW-PROFILE VENT (STANDARD FLANGE)DIVERTERS LOCALLY-APPROVED SEALANT ROOF DECK ASPHALT SHINGLES WIRE MESH INSECT SCREEN O'HAGIN'S TAPERED, LOW-PROFILE VENT (STANDARD FLANGE) O'HAGIN VENT SECTIONFOR COORDINATING ROOF TILE MANUFACTURERS, INSTALLATION INSTRUCTIONS, TECHNICAL BULLETINS & SPECIFIC INFORMATION REGARDING RAIN, SNOW, HIGH-VELOCITY WIND OR WILDLAND URBAN INTERFACE (WUI) APPLICATIONS, PLEASE CONTACT O’HAGIN TOLL FREE AT 877/324-0444 OR WWW.OHAGIN.COM O'HAGIN VENTS ARE MANUFACTURED USING: - PRE-PAINTED GALVANIZED 26 GAUGE G90 - GALVANIZED 26 GAUGE G90 - ALUMINUM .032 - COPPER 16 OZ - STAINLESS-STEEL INTERIOR MATRIX (WEATHERMASTER , WEATHERMASTER HD , FIRE & ICE ONLY) LOCALLY-APPROVED UNDERLAYMENT O'HAGIN LOW PROFILE VENT 1 1/2" = 1'-0" INSULATION BAFFLE J-MOLD CASING BEAD BACKER ROD AND SEALANT ASPHALT SHINGLE TILE ROOFING MATERIAL O/ W.P. PAPER O/ PLYWD. SHEATHING O/ 2X ROOF FRAMING PER STRUCT. 12 5 EXT. PLASTER O/ W.P. PAPER O/ PLYWD. SHEATHING O/ 2X FRAMING PER STRUCT. BATT INSULATION PER ENERGY CALCULATIONS. METAL DRIP FLASHING, FACTORY FINISHED. 5" BOX STYLE RAIN GUTTER & 3" DOWNSPOUT, PAINTED. 2X BLOCKING PER STRUCT. 2X RAFTER TAILS, 16" O.C. 2X FASCIA, PAINTED 2'-0" EAVE OVERHANG TYPICAL ROOF EAVE 1 1/2" = 1'-0" INSULATION BAFFLE J-MOLD CASING BEAD BACKER ROD AND SEALANT ASPHALT SHINGLE TILE ROOFING MATERIAL O/ W.P. PAPER O/ PLYWD. SHEATHING O/ 2X ROOF FRAMING PER STRUCT. 12 3 EXT. PLASTER O/ W.P. PAPER O/ PLYWD. SHEATHING O/ 2X FRAMING PER STRUCT. BATT INSULATION PER ENERGY CALCULATIONS. METAL DRIP FLASHING, FACTORY FINISHED. 5" BOX STYLE RAIN GUTTER & 3" DOWNSPOUT, PAINTED. 2X BLOCKING PER STRUCT. 2X RAFTER TAILS, 16" O.C. 2X FASCIA, PAINTED 2'-0" EAVE OVERHANG 3:12 ROOF EAVE 1 1/2" = 1'-0" INSULATION BAFFLE J-MOLD CASING BEAD BACKER ROD AND SEALANT 5:12 ROOF EAVE (1 FT OVERHANG) 1 1/2" = 1'-0" ASPHALT SHINGLE TILE ROOFING MATERIAL O/ W.P. PAPER O/ PLYWD. SHEATHING O/ 2X ROOF FRAMING PER STRUCT. EXT. PLASTER O/ W.P. PAPER O/ PLYWD. SHEATHING O/ 2X FRAMING PER STRUCT. 5" BOX STYLE RAIN GUTTER & 3" DOWNSPOUT, PAINTED. 2X BLOCKING PER STRUCT. 2X RAFTER TAILS, 16" O.C. 2X FASCIA, PAINTED 1'-0" EAVE OVERHANG FRAMING PER STRUCT. J-MOLD CASING BEAD BACKER ROD AND SEALANT BATT INSULATION PER ENERGY CALCULATIONS. 12 5 ASPHALT SHINGLE TILE ROOFING MATERIAL O/ W.P. PAPER O/ PLYWD. SHEATHING O/ 2X ROOF FRAMING PER STRUCT. EXT. PLASTER O/ W.P. PAPER O/ PLYWD. SHEATHING O/ 2X FRAMING PER STRUCT. 5" BOX STYLE RAIN GUTTER & 3" DOWNSPOUT, PAINTED. 2X BLOCKING PER STRUCT. 2X RAFTER TAILS, 16" O.C. 2X FASCIA, PAINTED 1'-0" EAVE OVERHANG J-MOLD CASING BEAD BACKER ROD AND SEALANT BATT INSULATION PER ENERGY CALCULATIONS. 12 3 3:12 ROOF EAVE (1 FT OVERHANG) 1 1/2" = 1'-0" INSULATION BAFFLE METAL DRIP FLASHING, FACTORY FINISHED. METAL DRIP FLASHING, FACTORY FINISHED. METAL DRIP FLASHING, FACTORY FINISHED. 1" MIN 1" MIN 1" MIN INSULATION BAFFLE 1" MIN 1" MIN 7/8" EXT. PLASTER O/ MTL. LATH O/ WATERPROOFING PAPER 2X RIP STRIP O/ PLYWD SHEATHING PER STRUCT. 1/2" : 12" SLOPE 20 GA. GALV. SHT MTL. PAN FLASHING W/ HEMMED EDGE OVER WATERPROOFING MEMBRANE OVER PLYWOOD. PRIMED AND PAINTED PER ELEVATION. SEALANT AND CASING BEAD 26 GA. GI. SHT. MTL. FLASHING UNDER WEEP SCREED AND OVER SHT. MTL. PAN FLASHING CANOPY 1 1/2" = 1'-0" PER PLAN 7/8" EXT. PLASTER OR HARDIEPANEL BOARD AND BATTEN SIDING O/ MTL. LATH O/ WATERPROOFING PAPER 2X FRAMING PER STRUCT. 2X BLOCKING 1X4 MIN. CONT. ASPHALT SHINGLE ROOFING O/ 30# FELT O/ 1/2" PLYWOOD SHEATHING CDX MIN. 2X AT 16" O.C. ROOF FRAMING PER STRUCTURE 26 GA. GALV. METAL 'Z' FLASHING LAP O/ BASE FLASHING EXT. PLASTER O/ W.P. PAPER & METAL LATH LAP W.P. O/ METAL FLASHING AND WEEP SCREED FLASHING AT ABUTTING RAKE WALL 3" = 1'-0" 2" 3" METAL 'Z' FLASHING ADHESIVE FLASHING ISOLATION PAPER (WRAP BLOCKING AND LAP ROOFING) 26 GA. GALV. MTL. PAN FLASHING W/ CRIMP EDGE EXTEND 8" MIN. AWAY FROM WALL TYPICAL RAKE DETAIL (BOARD AND BATTEN) 1 1/2" = 1'-0" ROOF SHEATHING PER STRUCTURAL. 26 GA (2"X6") G.I. METAL ROOF EDGE FLASHING. 2X FRAMING PER STRUCTURAL 7/8" EXT. PLASTER ASPHALT SHINGLE TILE ROOFING MATERIAL O/ W.P. PAPER O/ PLYWD. SHEATHING O/ 2X ROOF FRAMING PER STRUCT. TYPICAL RAKE DETAIL (EXT. PLASTER) 1 1/2" = 1'-0" ROOF SHEATHING PER STRUCTURAL. 26 GA (2"X6") G.I. METAL ROOF EDGE FLASHING. 2X FRAMING PER STRUCTURAL 2X8 WOOD BARGE BOARD, FINISH GRADE PAINTED. CASING BEAD W/ SEALANT AND BACKER ROD 7/8" EXT. PLASTER O/ MTL. LATH AND 15 LBS. FELT UNDERLAYMENT (PROVIDE 30 LBS. FELT UNDERLAYMENT WHERE APPYING O/ PLYWOOD SHEAR PANELS WHERE OCCURS). ASPHALT SHINGLE TILE ROOFING MATERIAL O/ W.P. PAPER O/ PLYWD. SHEATHING O/ 2X ROOF FRAMING PER STRUCT. 2X8 WOOD BARGE BOARD, FINISH GRADE PAINTED. CASING BEAD W/ SEALANT AND BACKER ROD HARDIETRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH SEALANT 6" OVERHANG HARDIEPANEL BOARD AND BATTEN SIDING O/ FELT UNDERLAYMENT O/ PLYWD SHEATHING PER STRUCT. 6" OVERHANG 26 GA. GALV. METAL FLASHING ASPHALT SHINGLES O/ 30# FELT O/ PLYWD. SHEATHING PER STRUCT. 2X LEDGER ROOF FRAMING PER STRUCTURE 2X AT 16" O.C. 1X4 MIN. CONT. 2X BLOCKING 26 GA. GALV. METAL 'Z' FLASHING LAP O/ BASE FLASHING ADHESIVE FLASHING ISOLATION PAPER 4" ROOF TO WALL FLASHING 1 1/2" = 1'-0" 2" 3" METAL 'Z' FLASHING EXT. PLASTER O/ W.P. PAPER & METAL LATH LAP W.P. O/ METAL FLASHING AND WEEP SCREED ROOF VENT FLASHING 1 1/2" = 1'-0" ROOF FRAMING ROOF SHEATHING (SEE STRUCTURAL) VENT PIPE FLEXIBLE CAP FLASHING W/ MIN. 9" SKIRT AROUND ROOF PROJECTION. ATTACH TO TILE W/ ROOFER'S MASTIC (2) LAYER UNDERLAYMENT (MIN. 30LB A.S.T.M. FELT MIN.) SEAL PIPE TO FLASHING WITH TOPS 850 ADHESIVE STORM COLLAR SET IN CONT. BEAD OF TOPS 850 ADHESIVE G.I. BASE MTL. FLASHING SET IN MASTIC 14 " 1"1" NOTES: COMBINE VENT PIPES AS MUCH AS POSSIBLE AND KEEP PENETRATIONS TO THE BACK SIDE OF THE ROOF. ROOF SHINGLES ROOF RAFTER 2X BLK'G 10" BASE FLASHING 1'- 0 " MI N . 1"10" BASE FLASHING VENT CAP 3" O B-VENT TO BE INSTALLED PER MANUF. SPEC. STORM COLLAR GAL. FLASHING LAP O/ROOF TILE W/MASTIC 26 GA. GAL. MTL FLASHING CARRY O/TILE 10" MIN. MOTAR FILL UNDERNEATH NOTE: 'METAL LAB INC" 3" DIA. MODEL M GAS VENT (B-VENT) OR EQ. UL MH7860, TEST #441B-VENT THRU ROOF 1 1/2" = 1'-0" 1" MIN. CLR. ROOF SHINGLES AREAS & O/ NAIL HOLES MASTIC AT OVERLAPPING OF APPROVED ROOFERS APPLY CONTINOUS BEAD MIN. 3" HEADLAP ONE 10D NAIL PER TILE UNDER RIDGE NAILER UNDERLAYMENT OVER AND MANUF. RECOMEND. RIDGE NAILER PER ROOF RIDGE NOT TO SCALE 2"WX 16 GA/ GALV. METALSTRAP NAILED TO ROOFRAFTER W/ (3) 10d NAILS * PROVIDE 4 STRAPS PER EACHATTIC FURNACE EQUIP. AT 90°TO EA. OTHER INSTALLED PER CMC. ATTIC EQUIPMENT ANCHOR 1 1/2" = 1'-0"6 3 4 ROOF DETAILS A3.2 ASPHALT SHINGLE TILE INFORMATION 7 8 11 12 9 10 15 16 13 14 17 18 19 1 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 20 2X BLOCKING 1X4 MIN. CONT. ASPHALT SHINGLE ROOFING O/ 30# FELT O/ 1/2" PLYWOOD SHEATHING CDX MIN. 2X AT 16" O.C. ROOF FRAMING PER STRUCTURE 26 GA. GALV. METAL 'Z' FLASHING LAP O/ BASE FLASHING FLASHING AT RAKE WALL AND BATTEN 3" = 1'-0" 2" 3" METAL 'Z' FLASHING ADHESIVE FLASHING ISOLATION PAPER (WRAP BLOCKING AND LAP ROOFING) 26 GA. GALV. MTL. PAN FLASHING W/ CRIMP EDGE EXTEND 8" MIN. AWAY FROM WALL HARDIETRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH HARDIEPANEL BOARD AND BATTEN SIDING O/ FELT UNDERLAYMENT O/ PLYWD SHEATHING PER STRUCT. 10 ' - 1 " 9' - 1 " 8' - 2 " 29 ' - 1 0 1 / 2 " BU I L D I N G H E I G H T ( 3 0 ' - 0 " M A X ) 10 ' - 1 " 9' - 1 " GARAGE OPENING (BEYOND) 29 ' - 1 0 1 / 2 " BU I L D I N G H E I G H T ( 3 0 ' - 0 " M A X ) SCALE: 1/4" = 1'-0" BUILDING 1 SOUTH ELEVATION 1 12 A B C 4 3 2 5 6 9 7 12 8 11 'DWELED' CALIBER LED OUTDOOR WALL LIGHT. MOUNTED 8'-0" A.F.F. COLOR: BLACK 1 'MILGARD®' VINYL WINDOW, MONTECITO® SERIES. COLOR: EXTERIOR - TAN, INTERIOR - WHITE. 10 WOOD DECORATIVE FRONT ENTRY DOOR, SELECT PER OWNER. COLOR: MATCH MILGARD® TAN 13 WOOD GATE/FENCE, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN. 14 2 X 10 WOOD BARGEBOARD, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN. 15 16 WOOD BALCONY, PAINTED, COLOR: MATCH LAP SIDING OF CORRESPONDING UNIT. EXTERIOR PLASTER, SMOOTH FINISH, O/ 'ANGELUS BLOCK' CMU RETAINING WALL COLOR: 'LA HABRA' 40 DOVE GREY, BASE 200 WOOD DECK W/ ELASTOMERIC OR WATERPROOFED FINISH METAL FLAT CANOPY, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN 17 CONCRETE STEPS PER SITE PLAN 18 NEW A/C UNIT SET ON FIBERGLASS PAD 19 LANDSCAPING PER LANDSCAPE DRAWINGS 20 2X FASCIA, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN 21 BASEMENT EXHAUST SHAFT 22 'HARDIETRIM®' WINDOW/DOOR TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH, COLOR: ARCTIC WHITE 23 'HARDIETRIM®' WINDOW TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH, COLOR: KHAKI BROWN ELEVATION NOTES 24 'DURA' DL2 2-BIKE LOCKER UNIT, INSTALL PER MANUFACTURER SPECIFICATIONS AND INSTRUCTIONS. COLOR: GRAPHITE 25 TRASH ENCLOSURE GATE, PAINTED, W/ HORIZONTAL TOP BOLT AND SLEEVE AND BOTTOM ANCHOR AND SLEEVE. COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN 4 AD4 17 A3.2 4 AD4 17 AD2 6 & 7 AD1 20 A3.2 9 AD1 26 EXT. PLASTER O/ 'CONCRETE' WALL COLOR : 'LA HABRA' 40 DOVE GREY, BASE 200 4'-0"H at SIM. CONDITION 11 AD1 17,18 AD5 1 27 CONCRETE WHEELSTOP 28 CONCRETE CURB, SEE SITE PLAN 29 BOLLARD, SEE DETAIL 30 STUCCO E.J. (EXPANSION JOINT) PER ELEVATION 12 AD4 2 AD2 5" BOX STYLE RAIN GUTTER & 3" DOWNSPOUT, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN. 'OWENS CORNING' TRU DEFINITION® DURATION® COOL ASPHALT SHINGLE TILE COLOR: MOUNTAINSIDE (CRRC 0890-0016) EXTERIOR PLASTER, SMOOTH FINISH, COLOR: 'LA HABRA' 40 DOVE GREY, BASE 200 'MILGARD®' VINYL PATIO DOOR, MONTECITO® SERIES., COLOR: EXTERIOR - TAN, INTERIOR - WHITE. 1,2 AD2 'HARDIEPANEL®' BOARD AND BATTEN VERTICAL SIDING, SELECT CEDARMILL. COLOR: KHAKI BROWN 'HARDIEPLANK®' LAP SIDING, SELECT CEDARMILL, COLOR: HEATHERED MOSS 'HARDIEPLANK®' LAP SIDING, SELECT CEDARMILL, COLOR: BOOTHBAY BLUE 3 AD2 4 AD2 6 A3.2 31 CONCRETE SLAB AT PARKING GARAGE 20 12 5 11821 22 1911412 14 7 3 12 3 722 5 220 8 5 6 2061311 10 8 5 1293 14 9 1 A6.3 SCALE: 1/4" = 1'-0" BUILDING 1 EAST ELEVATION 2 A4.1 BUILDING 1 ELEVATIONS 7 15 15 151 2 22 6 17 14 19 26 8 223 16 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 6 30 12 BEYOND BEYOND 30 6 31 10 ' - 1 " 9' - 1 " 29 ' - 1 0 1 / 2 " BU I L D I N G H E I G H T ( 3 0 ' - 0 " M A X ) DRIVEWAY 9' - 1 " 10 ' - 1 " 29 ' - 1 0 1 / 2 " BU I L D I N G H E I G H T ( 3 0 ' - 0 " M A X ) 3' - 6 " 3' - 6 " 5'- 0 " 5' - 6 " 8'- 8 " SCALE: 1/4" = 1'-0" BUILDING 1 NORTH ELEVATION 1 21 C B A 4 3 2 5 6 9 7 12 8 11 'DWELED' CALIBER LED OUTDOOR WALL LIGHT. MOUNTED 8'-0" A.F.F. COLOR: BLACK 1 'MILGARD®' VINYL WINDOW, MONTECITO® SERIES. COLOR: EXTERIOR - TAN, INTERIOR - WHITE. 10 WOOD DECORATIVE FRONT ENTRY DOOR, SELECT PER OWNER. COLOR: MATCH MILGARD® TAN 13 WOOD GATE/FENCE, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN. 14 2 X 10 WOOD BARGEBOARD, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN. 15 16 WOOD BALCONY, PAINTED, COLOR: MATCH LAP SIDING OF CORRESPONDING UNIT. EXTERIOR PLASTER, SMOOTH FINISH, O/ 'ANGELUS BLOCK' CMU RETAINING WALL COLOR: 'LA HABRA' 40 DOVE GREY, BASE 200 WOOD DECK W/ ELASTOMERIC OR WATERPROOFED FINISH METAL FLAT CANOPY, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN 17 CONCRETE STEPS PER SITE PLAN 18 NEW A/C UNIT SET ON FIBERGLASS PAD 19 LANDSCAPING PER LANDSCAPE DRAWINGS 20 2X FASCIA, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN 21 BASEMENT EXHAUST SHAFT 22 'HARDIETRIM®' WINDOW/DOOR TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH, COLOR: ARCTIC WHITE 23 'HARDIETRIM®' WINDOW TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH, COLOR: KHAKI BROWN ELEVATION NOTES 24 'DURA' DL2 2-BIKE LOCKER UNIT, INSTALL PER MANUFACTURER SPECIFICATIONS AND INSTRUCTIONS. COLOR: GRAPHITE 25 TRASH ENCLOSURE GATE, PAINTED, W/ HORIZONTAL TOP BOLT AND SLEEVE AND BOTTOM ANCHOR AND SLEEVE. COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN 4 AD4 17 A3.2 4 AD4 17 AD2 6 & 7 AD1 20 A3.2 9 AD1 26 EXT. PLASTER O/ 'CONCRETE' WALL COLOR : 'LA HABRA' 40 DOVE GREY, BASE 200 4'-0"H at SIM. CONDITION 11 AD1 17,18 AD5 1 27 CONCRETE WHEELSTOP 28 CONCRETE CURB, SEE SITE PLAN 29 BOLLARD, SEE DETAIL 30 STUCCO E.J. (EXPANSION JOINT) PER ELEVATION 12 AD4 2 AD2 5" BOX STYLE RAIN GUTTER & 3" DOWNSPOUT, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN. 'OWENS CORNING' TRU DEFINITION® DURATION® COOL ASPHALT SHINGLE TILE COLOR: MOUNTAINSIDE (CRRC 0890-0016) EXTERIOR PLASTER, SMOOTH FINISH, COLOR: 'LA HABRA' 40 DOVE GREY, BASE 200 'MILGARD®' VINYL PATIO DOOR, MONTECITO® SERIES., COLOR: EXTERIOR - TAN, INTERIOR - WHITE. 1,2 AD2 'HARDIEPANEL®' BOARD AND BATTEN VERTICAL SIDING, SELECT CEDARMILL. COLOR: KHAKI BROWN 'HARDIEPLANK®' LAP SIDING, SELECT CEDARMILL, COLOR: HEATHERED MOSS 'HARDIEPLANK®' LAP SIDING, SELECT CEDARMILL, COLOR: BOOTHBAY BLUE 3 AD2 4 AD2 6 A3.2 31 CONCRETE SLAB AT PARKING GARAGE SCALE: 1/4" = 1'-0" BUILDING 1 WEST ELEVATION 2 A4.2 BUILDING 1 ELEVATIONS 12 1 6 127123 12 11 17 19143 11 14 12 31 18 13275620 18 112162023 22229 12 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 6 30 2323 6 30 14 30 10 ' - 1 " 9' - 1 " 8' - 8 " 29 ' - 1 0 1 / 2 " BU I L D I N G H E I G H T ( 3 0 ' - 0 " M A X ) 9' - 8 " 6' - 2 " ALFAROOEM ALFAROOEM 10 ' - 1 " 9' - 1 " 29 ' - 1 0 1 / 2 " BU I L D I N G H E I G H T ( 3 0 ' - 0 " M A X ) 4'- 3 " 3' - 6 " GA T E SCALE: 1/4" = 1'-0" BUILDING 2 NORTH ELEVATION 1 12 E F 4 3 2 5 6 9 7 12 8 11 'DWELED' CALIBER LED OUTDOOR WALL LIGHT. MOUNTED 8'-0" A.F.F. COLOR: BLACK 1 'MILGARD®' VINYL WINDOW, MONTECITO® SERIES. COLOR: EXTERIOR - TAN, INTERIOR - WHITE. 10 WOOD DECORATIVE FRONT ENTRY DOOR, SELECT PER OWNER. COLOR: MATCH MILGARD® TAN 13 WOOD GATE/FENCE, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN. 14 2 X 10 WOOD BARGEBOARD, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN. 15 16 WOOD BALCONY, PAINTED, COLOR: MATCH LAP SIDING OF CORRESPONDING UNIT. EXTERIOR PLASTER, SMOOTH FINISH, O/ 'ANGELUS BLOCK' CMU RETAINING WALL COLOR: 'LA HABRA' 40 DOVE GREY, BASE 200 WOOD DECK W/ ELASTOMERIC OR WATERPROOFED FINISH METAL FLAT CANOPY, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN 17 CONCRETE STEPS PER SITE PLAN 18 NEW A/C UNIT SET ON FIBERGLASS PAD 19 LANDSCAPING PER LANDSCAPE DRAWINGS 20 2X FASCIA, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN 21 BASEMENT EXHAUST SHAFT 22 'HARDIETRIM®' WINDOW/DOOR TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH, COLOR: ARCTIC WHITE 23 'HARDIETRIM®' WINDOW TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH, COLOR: KHAKI BROWN ELEVATION NOTES 24 'DURA' DL2 2-BIKE LOCKER UNIT, INSTALL PER MANUFACTURER SPECIFICATIONS AND INSTRUCTIONS. COLOR: GRAPHITE 25 TRASH ENCLOSURE GATE, PAINTED, W/ HORIZONTAL TOP BOLT AND SLEEVE AND BOTTOM ANCHOR AND SLEEVE. COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN 4 AD4 17 A3.2 4 AD4 17 AD2 6 & 7 AD1 20 A3.2 9 AD1 26 EXT. PLASTER O/ 'CONCRETE' WALL COLOR : 'LA HABRA' 40 DOVE GREY, BASE 200 4'-0"H at SIM. CONDITION 11 AD1 17,18 AD5 1 27 CONCRETE WHEELSTOP 28 CONCRETE CURB, SEE SITE PLAN 29 BOLLARD, SEE DETAIL 30 STUCCO E.J. (EXPANSION JOINT) PER ELEVATION 12 AD4 2 AD2 5" BOX STYLE RAIN GUTTER & 3" DOWNSPOUT, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN. 'OWENS CORNING' TRU DEFINITION® DURATION® COOL ASPHALT SHINGLE TILE COLOR: MOUNTAINSIDE (CRRC 0890-0016) EXTERIOR PLASTER, SMOOTH FINISH, COLOR: 'LA HABRA' 40 DOVE GREY, BASE 200 'MILGARD®' VINYL PATIO DOOR, MONTECITO® SERIES., COLOR: EXTERIOR - TAN, INTERIOR - WHITE. 1,2 AD2 'HARDIEPANEL®' BOARD AND BATTEN VERTICAL SIDING, SELECT CEDARMILL. COLOR: KHAKI BROWN 'HARDIEPLANK®' LAP SIDING, SELECT CEDARMILL, COLOR: HEATHERED MOSS 'HARDIEPLANK®' LAP SIDING, SELECT CEDARMILL, COLOR: BOOTHBAY BLUE 3 AD2 4 AD2 6 A3.2 31 CONCRETE SLAB AT PARKING GARAGE 13 111 2 821 12 7 5 2 13 523 2181 12 SCALE: 1/4" = 1'-0" BUILDING 2 EAST ELEVATION 2 A4.3 BUILDING 2 ELEVATIONS 1814 7 8 6 18 14 26 19 6 13 15 7 19224 D 239 920 924 1 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 31 30 3014 28 1 27930 117 3030 6 12 14 SIM. 26 10 ' - 1 " 9' - 1 " 29 ' - 1 0 1 / 2 " BU I L D I N G H E I G H T ( 3 0 ' - 0 " M A X ) DRIVEWAY 10 ' - 1 " 9' - 1 " 29 ' - 1 0 1 / 2 " BU I L D I N G H E I G H T ( 3 0 ' - 0 " M A X ) 3' - 6 " 3' - 6 " 5'- 0 " 5' - 6 " 8'- 8 " SCALE: 1/4" = 1'-0" BUILDING 2 SOUTH ELEVATION 1 12 F E D 4 3 2 5 6 9 7 12 8 11 'DWELED' CALIBER LED OUTDOOR WALL LIGHT. MOUNTED 8'-0" A.F.F. COLOR: BLACK 1 'MILGARD®' VINYL WINDOW, MONTECITO® SERIES. COLOR: EXTERIOR - TAN, INTERIOR - WHITE. 10 WOOD DECORATIVE FRONT ENTRY DOOR, SELECT PER OWNER. COLOR: MATCH MILGARD® TAN 13 WOOD GATE/FENCE, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN. 14 2 X 10 WOOD BARGEBOARD, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN. 15 16 WOOD BALCONY, PAINTED, COLOR: MATCH LAP SIDING OF CORRESPONDING UNIT. EXTERIOR PLASTER, SMOOTH FINISH, O/ 'ANGELUS BLOCK' CMU RETAINING WALL COLOR: 'LA HABRA' 40 DOVE GREY, BASE 200 WOOD DECK W/ ELASTOMERIC OR WATERPROOFED FINISH METAL FLAT CANOPY, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN 17 CONCRETE STEPS PER SITE PLAN 18 NEW A/C UNIT SET ON FIBERGLASS PAD 19 LANDSCAPING PER LANDSCAPE DRAWINGS 20 2X FASCIA, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN 21 BASEMENT EXHAUST SHAFT 22 'HARDIETRIM®' WINDOW/DOOR TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH, COLOR: ARCTIC WHITE 23 'HARDIETRIM®' WINDOW TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH, COLOR: KHAKI BROWN ELEVATION NOTES 24 'DURA' DL2 2-BIKE LOCKER UNIT, INSTALL PER MANUFACTURER SPECIFICATIONS AND INSTRUCTIONS. COLOR: GRAPHITE 25 TRASH ENCLOSURE GATE, PAINTED, W/ HORIZONTAL TOP BOLT AND SLEEVE AND BOTTOM ANCHOR AND SLEEVE. COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN 4 AD4 17 A3.2 4 AD4 17 AD2 6 & 7 AD1 20 A3.2 9 AD1 26 EXT. PLASTER O/ 'CONCRETE' WALL COLOR : 'LA HABRA' 40 DOVE GREY, BASE 200 4'-0"H at SIM. CONDITION 11 AD1 17,18 AD5 1 27 CONCRETE WHEELSTOP 28 CONCRETE CURB, SEE SITE PLAN 29 BOLLARD, SEE DETAIL 30 STUCCO E.J. (EXPANSION JOINT) PER ELEVATION 12 AD4 2 AD2 5" BOX STYLE RAIN GUTTER & 3" DOWNSPOUT, PAINTED, COLOR: 'DUNN-EDWARDS' DEC 756 WEATHERED BROWN. 'OWENS CORNING' TRU DEFINITION® DURATION® COOL ASPHALT SHINGLE TILE COLOR: MOUNTAINSIDE (CRRC 0890-0016) EXTERIOR PLASTER, SMOOTH FINISH, COLOR: 'LA HABRA' 40 DOVE GREY, BASE 200 'MILGARD®' VINYL PATIO DOOR, MONTECITO® SERIES., COLOR: EXTERIOR - TAN, INTERIOR - WHITE. 1,2 AD2 'HARDIEPANEL®' BOARD AND BATTEN VERTICAL SIDING, SELECT CEDARMILL. COLOR: KHAKI BROWN 'HARDIEPLANK®' LAP SIDING, SELECT CEDARMILL, COLOR: HEATHERED MOSS 'HARDIEPLANK®' LAP SIDING, SELECT CEDARMILL, COLOR: BOOTHBAY BLUE 3 AD2 4 AD2 6 A3.2 31 CONCRETE SLAB AT PARKING GARAGE SCALE: 1/4" = 1'-0" BUILDING 2 WEST ELEVATION 2 A4.4 BUILDING 2 ELEVATIONS 6 20 72 221 12 8 7 5 14 5 12197161 13 1 261111 12 1814 24 9 92526 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 31 6 30 30 22 LIVING ROOM LAUNDRY CLOSETHALLWAY UNIT 2 TYPE B CLOSET DRIVEWAY2-CAR GARAGE BATH 1 LIVING ROOM UNIT 1 TYPE A DINING ROOM HALLWAYBEDROOM 3 8' - 2 " 9' - 1 " 29 ' - 1 0 1 / 2 " BU I L D I N G H E I G H T ( 3 0 ' - 0 " M A X ) 10 ' - 1 " 7'- 6 1 / 2 " F.A.U. 10 ' - 1 " 9' - 1 " 29 ' - 1 0 1 / 2 " BU I L D I N G H E I G H T ( 3 0 ' - 0 " M A X ) 2-CAR GARAGE DRIVEWAY LIVING ROOM HALLWAY CLOSETLAUNDRY 8' - 8 " 8' - 8 " UNIT 1 TYPE A 3' - 6 " 8' - 2 " SCALE: 1/4" = 1'-0" BUILDING 1 SECTION 1 FLOOR/CEILING ASSEMBLY: CARPET ON PAD OR CERAMIC FLOOR TILE O/ MUDSET OR HARDWOOD FLOORING O/ 3/4" MIN. GYPCRETE O/ PLYWOOD SHEATHING O/ 2X FLOOR FRAMING PER STRUCT. DWG. CEILING SHALL BE ONE LAYER OF 5/8" GYP. BD. INCLUDE R-19 INSULATION BETWEEN FLOOR JOIST FRAMING WHERE INDICATED PER SECTION. NEW CMU BLOCK WALL (PER SEPARATE PERMIT) FAU PER ENERGY CALCULATIONS IN ATTIC SPACEPROVIDE 24" WIDE SOLID FLOORING ACCESS WAY AND 30" WORKING SPACE AT CONTROLS IN FRONT OF FAU. ALSO, PROVIDE POSITIVE ELECTRICAL DISCONNECT AND LIGHT OVER FAU CONTROLS IN THE ATTIC SPACE, UNIT TO BE SET ON ISOLATION PADS. CONCRETE FOOTING PER STRUCTURAL DWG. USE 'OWENS CORNING' R-38 FIBERGLASS INSULATION FOR 2X RAFTERS AT ALL VAULTED CEILING AREAS, TYP. ROOF/CEILING ASSEMBLY: CONCRETE ROOF TILE O/ WATERPROOFING MEMBRANE O/ PLYWOOD SHEATHING O/ 2X ROOF FRAMING PER STRUCT. DWG. INCLUDE R-19 BATT INSULATION AT UNDERSIDE OF ROOF SHEATHING & R-38 BATT INSULATION ON CEILING , TYP. CEILING SHALL BE ONE LAYER OF 5/8" GYP. BD. 5" BOX STYLE RAIN GUTTER & 3" DOWNSPOUT. VINYL WINDOW OR PATIO DOOR PER DOOR / WINDOW SCHEDULE. WOOD HANDRAIL. LANDSCAPE PER LANDSCAPE DWG. FIRE BLOCKING PER 2016 CRC SEC. R302.11: IS REQUIRED IN CONCEALED SPACES 10'-0" O.C.. HORIZONTALLY AND VERTICALLY AT THE CEILING AND FLOOR LEVELS, CONNECTIONS BETWEEN HORIZONTAL AND VERTICAL SPACES, CONCEALED SPACES BETWEEN STAIR AND LANDING, OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES, WIRES, CHIMNEYS AND FIREPLACES. 4" THK. CONC. SLAB (5" THK. AT DRIVEWAY, GARAGE & PARKING) W/ #4 REBAR @ 16" O.C. EA. WAY ON 2" SAND BED O/ 6 MIL. MIN. VAPOR BARRIER O/ COMPACTED SOIL. 10 AD1 EXTERIOR WALL ASSEMBLY: WHERE EXTERIOR PLASTER OCCURS: 7/8" EXTERIOR PLASTER O/ METAL LATH O/ 15# FELT UNDERLAYMENT. USE 2-15# FELT BACKING WHEN APPLIED O/ PLYWOOD (CBC 2506.4), O/ 2X STUD WALL FRAMING PER STRUCT. DWG. WHERE EXTERIOR PLASTER OCCURS: HARDIEPANEL W/ HARDIETRIM BATTEN BOARDS (12" O.C.) O/ 15# FELT UNDERLAYMENT. USE 2-15# FELT BACKING WHEN APPLIED O/ PLYWOOD (CBC 2506.4), O/ 2X STUD WALL FRAMING PER STRUCT. DWG. WHERE LAP SIDING OCCURS: HARDIEPLANK SIDING (6" EXPOSURE) O/ 15# FELT UNDERLAYMENT. USE 2-15# FELT BACKING WHEN APPLIED O/ PLYWOOD (CBC 2506.4), O/ 2X STUD WALL FRAMING PER STRUCT. DWG. INCLUDE R-21 INSULATION BETWEEN STUD WALL FRAMING. AT INTERIOR SPACES, USE ONE LAYER OF 5/8" GYP. BD. 1,2 AD2 BEAM OR PARALLAM PER STRUCT. DWG. POST PER STRUCT. DWG. 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 18 12 2X FRAMED SOFFIT. HEIGHTS PER REFLECTED CEILING PLAN. 6,7 AD1 DEX-O-TEX (ICC ESR-1757) O/ BALCONY FRAMING PER STRUCT. DWG. 16-19 AD2 16 A6.1 SECTION NOTES 3 AD2 BASEMENT CONCRETE RETAINING WALL PER STRUCT. DWG 4 AD2 19 DEX-O-TEX (ICC ESR-1757) O/ EXTERIOR WOOD DECK FRAMING PER STRUCT. DWG. 9 AD1 11 AD1 1-3 AD1 6 AD5 42" H LOW WALL.20 20 A6.1 1 3 1 INCLUDE R-13 INSULATION BETWEEN STUD WALL FRAMING AT INTERIOR SPACES WHERE INDICATED PER SECTION. 21 1 1 PROVIDE 1 1/8" PLYWOOD or OSB MECH. PLATFORM (SOLID BLOCK UNDER UNIT AND ALL EDGES (PROVIDE SOUND BATT UNDER ENTIRE PLATFORM), COORDINATE w/ NOTE 12/A5.1 22 23 CHAMBERLIN #C73 GARAGE DOOR OPENER OR EQUAL24 STAIRWAY PER PLANS 4 A4.1 8 A4.1 12 A4.1 13 AD1 14 AD1 15 AD1 18 AD1 19 AD1 20 AD1 3 A5.1 BUILDING SECTIONS SCALE: 1/4" = 1'-0" UNIT 1 SECTION 2 2 B CA 1 13 6 1915 10 4 1 2 TYP. TYP. TYP. 14 12 17 16 8 9 7 TYP. 1 11 10 TYP. 4 TYP. 19 13 6 3 TYP. 16 13 3 TYP. 1 21 TYP. 1 21 TYP. 1 18 AD1 20 AD1 19 AD1 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 22 24 TYP. of 4 23 TYP. 5 5 5 5 TYP. 23 TYP. 15 AD1 SIM. 19 AD2 14 AD1 SIM. 13 A3.2 15 3 BEYOND 16 16 20 AD2 20 AD2 9' - 1 " 8'- 8 " 29 ' - 1 0 1 / 2 " BU I L D I N G H E I G H T ( 3 0 ' - 0 " M A X ) 10 ' - 1 " LIVING ROOM UNIT 4 TYPE B2 LAUNDRYCLOSET CLOSETHALLWAY DRIVEWAY LIVING ROOMUNIT 3 TYPE B LAUNDRY CLOSETCLOSETHALLWAY GUEST PARKING SPACE F.A.U.F.A.U. DRIVEWAY CLOSET MASTER BATHBEDROOM 3 KITCHEN UNIT 2 TYPE B 10 ' - 1 " 9' - 1 " 29 ' - 1 0 1 / 2 " BU I L D I N G H E I G H T ( 3 0 ' - 0 " M A X ) 3' - 6 " 3' - 6 " 5'- 0 " 9' - 1 " 2' - 0 " 8'- 8 " F.A.U. SCALE: 1/4" = 1'-0" BUILDING 2 SECTION 1 FLOOR/CEILING ASSEMBLY: CARPET ON PAD OR CERAMIC FLOOR TILE O/ MUDSET OR HARDWOOD FLOORING O/ 3/4" MIN. GYPCRETE O/ PLYWOOD SHEATHING O/ 2X FLOOR FRAMING PER STRUCT. DWG. CEILING SHALL BE ONE LAYER OF 5/8" GYP. BD. INCLUDE R-19 INSULATION BETWEEN FLOOR JOIST FRAMING WHERE INDICATED PER SECTION. NEW CMU BLOCK WALL (PER SEPARATE PERMIT) FAU PER ENERGY CALCULATIONS IN ATTIC SPACEPROVIDE 24" WIDE SOLID FLOORING ACCESS WAY AND 30" WORKING SPACE AT CONTROLS IN FRONT OF FAU. ALSO, PROVIDE POSITIVE ELECTRICAL DISCONNECT AND LIGHT OVER FAU CONTROLS IN THE ATTIC SPACE, UNIT TO BE SET ON ISOLATION PADS. CONCRETE FOOTING PER STRUCTURAL DWG. USE 'OWENS CORNING' R-38 FIBERGLASS INSULATION FOR 2X RAFTERS AT ALL VAULTED CEILING AREAS, TYP. ROOF/CEILING ASSEMBLY: CONCRETE ROOF TILE O/ WATERPROOFING MEMBRANE O/ PLYWOOD SHEATHING O/ 2X ROOF FRAMING PER STRUCT. DWG. INCLUDE R-19 BATT INSULATION AT UNDERSIDE OF ROOF SHEATHING & R-38 BATT INSULATION ON CEILING , TYP. CEILING SHALL BE ONE LAYER OF 5/8" GYP. BD. 5" BOX STYLE RAIN GUTTER & 3" DOWNSPOUT. VINYL WINDOW OR PATIO DOOR PER DOOR / WINDOW SCHEDULE. WOOD HANDRAIL. LANDSCAPE PER LANDSCAPE DWG. FIRE BLOCKING PER 2016 CRC SEC. R302.11: IS REQUIRED IN CONCEALED SPACES 10'-0" O.C.. HORIZONTALLY AND VERTICALLY AT THE CEILING AND FLOOR LEVELS, CONNECTIONS BETWEEN HORIZONTAL AND VERTICAL SPACES, CONCEALED SPACES BETWEEN STAIR AND LANDING, OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES, WIRES, CHIMNEYS AND FIREPLACES. 4" THK. CONC. SLAB (5" THK. AT DRIVEWAY, GARAGE & PARKING) W/ #4 REBAR @ 16" O.C. EA. WAY ON 2" SAND BED O/ 6 MIL. MIN. VAPOR BARRIER O/ COMPACTED SOIL. 10 AD1 EXTERIOR WALL ASSEMBLY: WHERE EXTERIOR PLASTER OCCURS: 7/8" EXTERIOR PLASTER O/ METAL LATH O/ 15# FELT UNDERLAYMENT. USE 2-15# FELT BACKING WHEN APPLIED O/ PLYWOOD (CBC 2506.4), O/ 2X STUD WALL FRAMING PER STRUCT. DWG. WHERE EXTERIOR PLASTER OCCURS: HARDIEPANEL W/ HARDIETRIM BATTEN BOARDS (12" O.C.) O/ 15# FELT UNDERLAYMENT. USE 2-15# FELT BACKING WHEN APPLIED O/ PLYWOOD (CBC 2506.4), O/ 2X STUD WALL FRAMING PER STRUCT. DWG. WHERE LAP SIDING OCCURS: HARDIEPLANK SIDING (6" EXPOSURE) O/ 15# FELT UNDERLAYMENT. USE 2-15# FELT BACKING WHEN APPLIED O/ PLYWOOD (CBC 2506.4), O/ 2X STUD WALL FRAMING PER STRUCT. DWG. INCLUDE R-21 INSULATION BETWEEN STUD WALL FRAMING. AT INTERIOR SPACES, USE ONE LAYER OF 5/8" GYP. BD. 1,2 AD2 BEAM OR PARALLAM PER STRUCT. DWG. POST PER STRUCT. DWG. 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 18 12 2X FRAMED SOFFIT. HEIGHTS PER REFLECTED CEILING PLAN. 6,7 AD1 DEX-O-TEX (ICC ESR-1757) O/ BALCONY FRAMING PER STRUCT. DWG. 16-19 AD2 16 A6.1 SECTION NOTES 3 AD2 BASEMENT CONCRETE RETAINING WALL PER STRUCT. DWG 4 AD2 19 DEX-O-TEX (ICC ESR-1757) O/ EXTERIOR WOOD DECK FRAMING PER STRUCT. DWG. 9 AD1 11 AD1 1-3 AD1 6 AD5 42" H LOW WALL.20 20 A6.1 1 3 1 INCLUDE R-13 INSULATION BETWEEN STUD WALL FRAMING AT INTERIOR SPACES WHERE INDICATED PER SECTION. 21 1 1 PROVIDE 1 1/8" PLYWOOD or OSB MECH. PLATFORM (SOLID BLOCK UNDER UNIT AND ALL EDGES (PROVIDE SOUND BATT UNDER ENTIRE PLATFORM), COORDINATE w/ NOTE 12/A5.1 22 23 CHAMBERLIN #C73 GARAGE DOOR OPENER OR EQUAL24 STAIRWAY PER PLANS 4 A4.1 8 A4.1 12 A4.1 13 AD1 14 AD1 15 AD1 18 AD1 19 AD1 20 AD1 3 A5.2 BUILDING SECTIONS E FD SCALE: 1/4" = 1'-0" UNIT 2 SECTION 2 1 2 9 4 1 TYP. TYP. 12 TYP. 16 TYP. 13 13 2 TYP. TYP. 6 19 10 17 18 11 1 TYP. TYP. TYP. 3 16 TYP. 19 14 4 6 TYP. 21 TYP. 1 3 TYP. 1 17 22 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 12 5 5 5 5 22 9 TYP.23 TYP. 15 AD1 SIM. 19 AD2 14 AD1 13 AD1 14 18 AD1 20 AD1 19 AD1 19 AD1 16 16 20 AD2 20 AD2 2-CAR GARAGE DRIVEWAY BEDROOM 1 DINING ROOM BEDROOM 2 HALLWAY MASTER BEDROOM UNIT 3 TYPE B 3' - 6 " 3'- 8 " 10 ' - 1 " 9' - 1 " 29 ' - 1 0 1 / 2 " BU I L D I N G H E I G H T ( 3 0 ' - 0 " M A X ) 8' - 7 " 1' - 6 " 8'- 8 " 10 ' - 1 " 9' - 1 " 29 ' - 1 0 1 / 2 " BU I L D I N G H E I G H T ( 3 0 ' - 0 " M A X ) 2-CAR GARAGE DRIVEWAY LIVING ROOMKITCHEN BATH 3W.I.C.HALLWAYMASTER BEDROOM UNIT 4 TYPE B2 3' - 6 " 3' - 6 " 8'- 8 " SCALE: 1/4" = 1'-0" UNIT 3 SECTION 1 2 FLOOR/CEILING ASSEMBLY: CARPET ON PAD OR CERAMIC FLOOR TILE O/ MUDSET OR HARDWOOD FLOORING O/ 3/4" MIN. GYPCRETE O/ PLYWOOD SHEATHING O/ 2X FLOOR FRAMING PER STRUCT. DWG. CEILING SHALL BE ONE LAYER OF 5/8" GYP. BD. INCLUDE R-19 INSULATION BETWEEN FLOOR JOIST FRAMING WHERE INDICATED PER SECTION. NEW CMU BLOCK WALL (PER SEPARATE PERMIT) FAU PER ENERGY CALCULATIONS IN ATTIC SPACEPROVIDE 24" WIDE SOLID FLOORING ACCESS WAY AND 30" WORKING SPACE AT CONTROLS IN FRONT OF FAU. ALSO, PROVIDE POSITIVE ELECTRICAL DISCONNECT AND LIGHT OVER FAU CONTROLS IN THE ATTIC SPACE, UNIT TO BE SET ON ISOLATION PADS. CONCRETE FOOTING PER STRUCTURAL DWG. USE 'OWENS CORNING' R-38 FIBERGLASS INSULATION FOR 2X RAFTERS AT ALL VAULTED CEILING AREAS, TYP. ROOF/CEILING ASSEMBLY: CONCRETE ROOF TILE O/ WATERPROOFING MEMBRANE O/ PLYWOOD SHEATHING O/ 2X ROOF FRAMING PER STRUCT. DWG. INCLUDE R-19 BATT INSULATION AT UNDERSIDE OF ROOF SHEATHING & R-38 BATT INSULATION ON CEILING , TYP. CEILING SHALL BE ONE LAYER OF 5/8" GYP. BD. 5" BOX STYLE RAIN GUTTER & 3" DOWNSPOUT. VINYL WINDOW OR PATIO DOOR PER DOOR / WINDOW SCHEDULE. WOOD HANDRAIL. LANDSCAPE PER LANDSCAPE DWG. FIRE BLOCKING PER 2016 CRC SEC. R302.11: IS REQUIRED IN CONCEALED SPACES 10'-0" O.C.. HORIZONTALLY AND VERTICALLY AT THE CEILING AND FLOOR LEVELS, CONNECTIONS BETWEEN HORIZONTAL AND VERTICAL SPACES, CONCEALED SPACES BETWEEN STAIR AND LANDING, OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES, WIRES, CHIMNEYS AND FIREPLACES. 4" THK. CONC. SLAB (5" THK. AT DRIVEWAY, GARAGE & PARKING) W/ #4 REBAR @ 16" O.C. EA. WAY ON 2" SAND BED O/ 6 MIL. MIN. VAPOR BARRIER O/ COMPACTED SOIL. 10 AD1 EXTERIOR WALL ASSEMBLY: WHERE EXTERIOR PLASTER OCCURS: 7/8" EXTERIOR PLASTER O/ METAL LATH O/ 15# FELT UNDERLAYMENT. USE 2-15# FELT BACKING WHEN APPLIED O/ PLYWOOD (CBC 2506.4), O/ 2X STUD WALL FRAMING PER STRUCT. DWG. WHERE EXTERIOR PLASTER OCCURS: HARDIEPANEL W/ HARDIETRIM BATTEN BOARDS (12" O.C.) O/ 15# FELT UNDERLAYMENT. USE 2-15# FELT BACKING WHEN APPLIED O/ PLYWOOD (CBC 2506.4), O/ 2X STUD WALL FRAMING PER STRUCT. DWG. WHERE LAP SIDING OCCURS: HARDIEPLANK SIDING (6" EXPOSURE) O/ 15# FELT UNDERLAYMENT. USE 2-15# FELT BACKING WHEN APPLIED O/ PLYWOOD (CBC 2506.4), O/ 2X STUD WALL FRAMING PER STRUCT. DWG. INCLUDE R-21 INSULATION BETWEEN STUD WALL FRAMING. AT INTERIOR SPACES, USE ONE LAYER OF 5/8" GYP. BD. 1,2 AD2 BEAM OR PARALLAM PER STRUCT. DWG. POST PER STRUCT. DWG. 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 18 12 2X FRAMED SOFFIT. HEIGHTS PER REFLECTED CEILING PLAN. 6,7 AD1 DEX-O-TEX (ICC ESR-1757) O/ BALCONY FRAMING PER STRUCT. DWG. 16-19 AD2 16 A6.1 SECTION NOTES 3 AD2 BASEMENT CONCRETE RETAINING WALL PER STRUCT. DWG 4 AD2 19 DEX-O-TEX (ICC ESR-1757) O/ EXTERIOR WOOD DECK FRAMING PER STRUCT. DWG. 9 AD1 11 AD1 1-3 AD1 6 AD5 42" H LOW WALL.20 20 A6.1 1 3 1 INCLUDE R-13 INSULATION BETWEEN STUD WALL FRAMING AT INTERIOR SPACES WHERE INDICATED PER SECTION. 21 1 1 PROVIDE 1 1/8" PLYWOOD or OSB MECH. PLATFORM (SOLID BLOCK UNDER UNIT AND ALL EDGES (PROVIDE SOUND BATT UNDER ENTIRE PLATFORM), COORDINATE w/ NOTE 12/A5.1 22 23 CHAMBERLIN #C73 GARAGE DOOR OPENER OR EQUAL24 STAIRWAY PER PLANS 4 A4.1 8 A4.1 12 A4.1 13 AD1 14 AD1 15 AD1 18 AD1 19 AD1 20 AD1 3 A5.3 BUILDING SECTIONS 1 12 SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0" UNIT 4 SECTION 2 2 TYP. 19 14 4 10 1 TYP. TYP. 13 TYP. 11 19 14 3 TYP. 13 TYP. 2 TYP. 14 4 11 1 TYP. TYP. 3 TYP. 10 TYP. 19 13 TYP. 6 16 TYP. 19 14 TYP. 6 TYP.16 TYP. 21 TYP. 1 21 TYP. 1 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 23 TYP. 9 15 AD1 SIM. 19 AD2 14 AD1 13 A3.2 17 17 TYP. 17 TYP. 2525 25 15 20 AD2 20 AD2 SIM. 20 AD2 20 AD2 8'- 1 0 3 / 4 " 14 R @ 7 5 / 8 " E A . 11 ' - 1 " 18 R @ 7 . 3 9 " E A . 3' - 0 " HA N D R A I L H E I G H T 6' - 8 " MI N . H E A D R O O M C L E A R A N C E 6' - 8 " MI N . H E A D R O O M C L E A R A N C E 6'-8" 8T @ 10" EA. 10'-10" 13T @ 10" EA. 3'- 0 " HA N D R A I L H E I G H T 3'-4" STAIR PLATFORM 4'-2"5T @ 10" EA.3'-2 1/2" STAIR PLATFORM 7'-6" 9T @ 10" EA. 3'- 0 " HA N D R A I L H E I G H T 3'-9 1/2" STAIR PLATFORM 10'-10" 13T @ 10" EA. 3' - 0 " HA N D R A I L H E I G H T 6' - 8 " MI N . H E A D R O O M C L E A R A N C E 6' - 8 " MI N . H E A D R O O M C L E A R A N C E 8' - 4 1 / 4 " 14 R @ 7 . 1 7 " E A . 11 ' - 1 " 18 R @ 7 . 3 9 " E A . 1" TREAD PER PLAN DOWN STRINGER & LANDING 1 1/2" = 1'-0" FINISH FLOOR PER OWNER 8 1 / 2 " M I N . N O O V E R C U T S 3/4" THK GYPCRETE O/ PLYWOOD PER STRUCT. RI S E R P E R PL A N 2X STRINGER PER STRUCT. HANGER PER STRUCT. BEAM OR RIM JOIST PER STRUCT. 2X F.J. PER STRUCT. 3/4" PLYWOOD, GLUE AND NAIL ALL EDGES 3/4" WOOD STOP BLOCKING 8 1/ 2 " M I N . NO O V E R C U T S TREAD PER PLAN RI S E R P E R PL A N UP STRINGER & LANDING 1 1/2" = 1'-0" FINISH FLOOR PER OWNER 1" 3/4" PLYWOOD, GLUE AND NAIL ALL EDGES 3/4" PLYWOOD TREADS AND RISERS 2X JOISTS @ 16" O.C. PER STRUCT. BEAM OR RIM JOIST PER STRUCT. 2X STRINGER PER STRUCT. HANGER PER STRUCT. CONC. DECK TREAD PER PLAN RI S E R PE R P L A N 8 1 / 2 " M I N . NO O V E R C U T S 1" UP STRINGER 1 1/2" = 1'-0" FINISH FLOOR PER OWNER 3/4" PLYWOOD, GLUE AND NAIL ALL EDGES 2X P.T.D.F. THRUST PLATE PER STRUCT. NOTCH STRINGER FOR PLATE, ATTACH PER STRUCT. 3/ 4 " 1/ 2 " PE R S E C T I O N 1 1/2" 05 7 2 0 - 0 5 TYPICAL LOW WALL W/ WOOD HANDRAIL 3" = 1'-0" 1X MAPLE WOOD CAP PER PLAN 16 - PAINT WHITE ON INSIDE FACE ONLY CORNER BEAD (2) 2X4 CONTINUOUS TOP PLATE - OVERLAP PLATES @ CORNERS 5/8" GYP. BD. BOTH SIDES OF 2X4 STUDS 34 " - 3 8 " PE R S E C T I O N WD HANDRAIL PER DETAIL AND PLAN NOTE: ATTACHED PER MANUFACTURES REQ. TREAD NOSING FACE OF WALL FINISH, SEE WALL TYPES RETURN END TO WALL BEYOND 3'-0" ABOVE HANDRAIL @ STUD WALL 6"=1'-0" 1/4" 1 1/2" 1 1/2"Ø HANDRAIL RAILING PER PLAN W/ STAINLESS STEEL STANCHION (STANCHION SPACING PER MFR.) ATTACHED PER MANUFACTURES REQ. 2 X SOLID WOOD BLOCKING AT EACH STANCHION BUILDING STAIR SECTIONS A6.1 SCALE: 1/2" = 1'-0" 2TYPE B & B2 STAIR SECTION SCALE: 1/2" = 1'-0" 1TYPE A STAIR SECTION 48121620 FLOOR/CEILING ASSEMBLY: CARPET ON PAD OR CERAMIC FLOOR TILE O/ MUDSET OR HARDWOOD FLOORING O/ 3/4" MIN. GYPCRETE O/ PLYWOOD SHEATHING O/ 2X FLOOR FRAMING PER STRUCT. DWG. CEILING SHALL BE ONE LAYER OF 5/8" GYP. BD. INCLUDE R-19 INSULATION BETWEEN FLOOR JOIST FRAMING WHERE INDICATED PER SECTION. NEW CMU BLOCK WALL (PER SEPARATE PERMIT) FAU PER ENERGY CALCULATIONS IN ATTIC SPACEPROVIDE 24" WIDE SOLID FLOORING ACCESS WAY AND 30" WORKING SPACE AT CONTROLS IN FRONT OF FAU. ALSO, PROVIDE POSITIVE ELECTRICAL DISCONNECT AND LIGHT OVER FAU CONTROLS IN THE ATTIC SPACE, UNIT TO BE SET ON ISOLATION PADS. CONCRETE FOOTING PER STRUCTURAL DWG. USE 'OWENS CORNING' R-38 FIBERGLASS INSULATION FOR 2X RAFTERS AT ALL VAULTED CEILING AREAS, TYP. ROOF/CEILING ASSEMBLY: CONCRETE ROOF TILE O/ WATERPROOFING MEMBRANE O/ PLYWOOD SHEATHING O/ 2X ROOF FRAMING PER STRUCT. DWG. INCLUDE R-19 BATT INSULATION AT UNDERSIDE OF ROOF SHEATHING & R-38 BATT INSULATION ON CEILING , TYP. CEILING SHALL BE ONE LAYER OF 5/8" GYP. BD. 5" BOX STYLE RAIN GUTTER & 3" DOWNSPOUT. VINYL WINDOW OR PATIO DOOR PER DOOR / WINDOW SCHEDULE. WOOD HANDRAIL. LANDSCAPE PER LANDSCAPE DWG. FIRE BLOCKING PER 2016 CRC SEC. R302.11: IS REQUIRED IN CONCEALED SPACES 10'-0" O.C.. HORIZONTALLY AND VERTICALLY AT THE CEILING AND FLOOR LEVELS, CONNECTIONS BETWEEN HORIZONTAL AND VERTICAL SPACES, CONCEALED SPACES BETWEEN STAIR AND LANDING, OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES, WIRES, CHIMNEYS AND FIREPLACES. 4" THK. CONC. SLAB (5" THK. AT DRIVEWAY, GARAGE & PARKING) W/ #4 REBAR @ 16" O.C. EA. WAY ON 2" SAND BED O/ 6 MIL. MIN. VAPOR BARRIER O/ COMPACTED SOIL. 10 AD1 EXTERIOR WALL ASSEMBLY: WHERE EXTERIOR PLASTER OCCURS: 7/8" EXTERIOR PLASTER O/ METAL LATH O/ 15# FELT UNDERLAYMENT. USE 2-15# FELT BACKING WHEN APPLIED O/ PLYWOOD (CBC 2506.4), O/ 2X STUD WALL FRAMING PER STRUCT. DWG. WHERE EXTERIOR PLASTER OCCURS: HARDIEPANEL W/ HARDIETRIM BATTEN BOARDS (12" O.C.) O/ 15# FELT UNDERLAYMENT. USE 2-15# FELT BACKING WHEN APPLIED O/ PLYWOOD (CBC 2506.4), O/ 2X STUD WALL FRAMING PER STRUCT. DWG. WHERE LAP SIDING OCCURS: HARDIEPLANK SIDING (6" EXPOSURE) O/ 15# FELT UNDERLAYMENT. USE 2-15# FELT BACKING WHEN APPLIED O/ PLYWOOD (CBC 2506.4), O/ 2X STUD WALL FRAMING PER STRUCT. DWG. INCLUDE R-21 INSULATION BETWEEN STUD WALL FRAMING. AT INTERIOR SPACES, USE ONE LAYER OF 5/8" GYP. BD. 1,2 AD2 BEAM OR PARALLAM PER STRUCT. DWG. POST PER STRUCT. DWG. 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 18 12 2X FRAMED SOFFIT. HEIGHTS PER REFLECTED CEILING PLAN. 6,7 AD1 DEX-O-TEX (ICC ESR-1757) O/ BALCONY FRAMING PER STRUCT. DWG. 16-19 AD2 16 A6.1 SECTION NOTES 3 AD2 BASEMENT CONCRETE RETAINING WALL PER STRUCT. DWG 4 AD2 19 DEX-O-TEX (ICC ESR-1757) O/ EXTERIOR WOOD DECK FRAMING PER STRUCT. DWG. 9 AD1 11 AD1 1-3 AD1 6 AD5 42" H LOW WALL.20 20 A6.1 1 3 1 INCLUDE R-13 INSULATION BETWEEN STUD WALL FRAMING AT INTERIOR SPACES WHERE INDICATED PER SECTION. 21 1 1 PROVIDE 1 1/8" PLYWOOD or OSB MECH. PLATFORM (SOLID BLOCK UNDER UNIT AND ALL EDGES (PROVIDE SOUND BATT UNDER ENTIRE PLATFORM), COORDINATE w/ NOTE 12/A5.1 22 23 CHAMBERLIN #C73 GARAGE DOOR OPENER OR EQUAL24 STAIRWAY PER PLANS 4 A4.1 8 A4.1 12 A4.1 13 AD1 14 AD1 15 AD1 18 AD1 19 AD1 20 AD1 3 NOTE: UNIT 2 STAIR SECTION SHOWN. UNIT 3 STAIR SECTION IS MIRRORED. UNIT 4 STAIR SECTION IS SIMILAR. 3 TYP. 4 TYP. 19 13 16 6 9 9 4 TYP. 6 TYP. 9 9 20 17 8 16 TYP. 3 TYP. 21 TYP.21 TYP. 11 8 A6.1 TYP. 4 A6.1 TYP. at CONC. 12 A6.1 TYP. Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 12 A6.1 TYP. 4 A6.1 TYP. at CONC. 8 A6.1 TYP. 447.50' G / M 449.50' 450.00' 447.50' 12R DN 449.50'4R UP 2" 13R DN 449.25' 450.00' 440.50' 4' - 3 " 6' - 8 " MI N . H E A D R O O M C L E A R A N C E 8'- 9 " 15 R @ 7 " E A . 10'-10" 13T @ 10" EA. 449.25' 3' - 6 " 450.00' 3' - 0 " HA N D R A I L H E I G H T 1'-11" 11" 6' - 6 " 13 R @ 6 " E A . 10'-0" 12T @ 10" EA. 6' - 8 " MI N . H E A D R O O M C L E A R A N C E 3'- 0 " HA N D R A I L H E I G H T 447.50' 441.00' 3'- 6 " 3' - 6 " 450.00' 1'-11" 2'- 0 " 4R @ 6 " E A . 2'-6" 3T @ 10" EA. 6'- 8 " MI N . H E A D R O O M C L E A R A N C E 3'- 0 " HA N D R A I L H E I G H T 447.50' 3'- 6 " 450.00' 11" 449.50'TREAD NOSING 34" TO 38" ABOVE WALL. EXTERIOR FINISH WHERE OCCURS PER PLAN. ENDS SHALL BE RETURNED 1 1/2" MIN. 1/4" HANDRAIL AT CMU WALL 6" = 1'-0" OR RAMP SURFACE HANDRAIL ANCHOR TO MASONRY WALL W/CONCRETE LAG SCREWSSET IN LEAD SHIELDS. 1 1/2"Ø HANDRAIL RAILINGPER PLAN W/ STAINLESSSTEEL STANCHION(STANCHION SPACING PER MFR.) CMU WALL WHERE OCCURS PER PLAN. OUTDOOR CONCRETE STEP 1 1/2" = 1'-0" REBAR PER STRUCTURAL 1/4" RADIUS CORNER TYP. 1"SEE PLAN 11" MIN. SE E P L A N 7" M A X . OUTDOOR CONCRETE STEP 1 1/2" = 1'-0" REBAR PER STRUCTURAL 1/4" RADIUS CORNER TYP. SEE PLAN 11" MIN. SE E P L A N 7" M A X . 1" SCALE: 1/2" = 1'-0" SOUTHWEST SITE STAIR PLAN & SECTION 1 SITE STAIR SECTIONS A6.2 SCALE: 1/2" = 1'-0" NORTHEAST SITE STAIR PLAN &SECTION 2 SECTION PLAN NORTH B A SECTION B APLAN NORTH 2B - 1B - 12 - 121620 12 - 16 - 16 - 12 - SECTION C 1C - 16 - 12 - 12 - 12 - 1 1 1 1 1 1 1 11 1 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 6 AD1 6 AD1 NOTES: 1. VERIFY LOCATION OF UNDERGROUND UTILITIES BEFORE DRILLING FOR CONCRETE FOUNDATION 2. DIMENSION (D) OF ROUNDED CONCRETE CAP SHALL BE 1/4 PIPE DIAMETER ROUNDED CONCRETE CAP PAINT (2) COATS TRAFFIC YELLOW, U.N.O. 8" DIA. STANDARD STEEL PIPE (UNLESS NOTED OTHERWISE)FILLED W/ CONCRETE CEMENT WASH SLOPED 1" ABOVE ADJ.GRADE w/ TOOLED EDGE at 24" DIA. CONCRETE FOUNDATION 3,500 PSI. 6" 2'-0" 3' - 6 " 4'- 2 " 'D ' CONCRETE PAVING PER CIVIL PROVIDE E.J. @ CONCRETE PAVINGLOCATIONS COMPACTED FILL, PER SOILS REPORT EXTERIOR PIPE BOLLARD 3" = 1'-0"19 6% DOWN 8'-0" 12% DOWN 8'-0" 20% DOWN 19'-4" 10% DOWN 8'-0" 3'-0" 6" H CURB 446.63' 441.80' 441.00' 447.11' 441.30' DRIVEWAY AISLE BETWEEN UNITS 1 AND 2 4.42% DOWN 9'-6" GENOA AVE PR O P E R T Y LI N E DRIVEYWAY APRON PER CITY STANDARD 445.67' 440.58' 12'-6" 8' - 5 " C L R . MI N . NOTE: COORDINATE WITH CIVIL AND STRUCTURAL DISCIPLINE SCALE: 3/8" = 1'-0" VERTICAL CURVE / RAMP PROFILE 1 SITE SECTIONS A6.3 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update WINDOW SCHEDULE NOTE: ALL WINDOWS TO BE 'MILGARD®' VINYL WINDOWS, MONTECITO® SERIES. EXTERIOR COLOR: TAN, INTERIOR COLOR: WHITE. WIDTH HEIGHT#TYPE HORIZONTAL SLIDER FRAME MATERIAL EXTERIOR GLAZING VINYL TAN INTERIOR WHITE FRAME FINISH DUAL LOW-E W/ ARGON GAS FIXED DOOR SCHEDULE WIDTH THK.#TYPEMODE MATERIAL FINISH FRAMEHEIGHTFACEFINISH DOOR 6'-0"4'-0" 16'-0"2"METAL-7'-0" SECTIONAL OVERHEAD INSULATED STEEL GARAGE DOOR FACTORY PAINTED1 2 3 4 5 FINISH FLOOR LINE 8'-0"3'-0"1 3/4"PAIR PLANKWOOD DECORATIVE FRONT ENTRY DOOR WOODSTAINED SELECT PER OWNER EXTERIOR GARAGE DOOR STYLE SHALL BE SELECT PER OWNER, PROVIDE POWER REMARKS 2'-0"AWNING 2'-6"6'-6" WINDOW TYPES (SCALE: 3/16" = 1'-0") 8'-0" HEADER NOTE: THE NFRC TEMPORARY LABEL DISPLAYED ON WINDOWS MUST REMAIN ON THE UNIT UNTIL FINAL INSPECTION HAS BEEN COMPLETED. A HEADER HEIGHT 8'-0" 7'-0"B C D 8'-0" FIXED | AWNING | FIXED 9'-0" 2'-0"8'-0" 10'-6" E F G H J K L M N 9'-0"6'-8"SLIDING PATIO DOORS3-PANEL (XOO) PAINTED A DOOR TYPES (SCALE: 3/16" = 1'-0") FIXED HORIZONTAL SLIDER4'-0"3'-6" B 7'-0" C 2'-0" 2'-0"5'-6"8'-0" FIXED | FIXED TOP SASH HEIGHT: 4'-0" BOTTOM SASH HEIGHT: 2'-6" 8'-0"2'-0"7'-0" 7'-0" HEADER D TOP FIXED SASH HEIGHT: 3'-0", MIDDLE AWNING AND BOTTOM SASH HEIGHT: 2'-0" E F G H J 6'-8"HORIZONTAL SLIDER FIXED | FIXED 8'-9" HEADER HEIGHT TRANSOM WINDOW BOTH SASH WIDTHS: 2'-10" 6'-0"2'-0" K FINISH FLOOR LINE 8'-0" HEADER L 8'-0" M N 2'-6"FIXED FIXED 4'-0" 2'-6"2'-0" FINISH FLOOR LINE 8'-0" HEADER 7'-0" HEADER 2 5'-0"PAIR 2 RECESSED PANEL PAINTED WOOD PAINTED WOOD1 3/8"2'-6"SINGLE SWING WOOD S.C. 1 1/2" SLIDING CLOSET DOOR (XO) 1 8'-0"3'-0"SINGLE SWING PATIO DOOR 3 4 DUAL LOW-E W/ ARGON GAS VINYL DUAL TEMPERED GLAZING HARDIE TRIM at OPEN'G 5 PAIR (XO) DUAL LOW-E W/ ARGON GAS VINYL DUAL TEMPERED GLAZING 6'-0"8'-0"SLIDING PATIO DOORS 1 7/8" 1 7/8" TTT T T T DUAL LOW-E W/ ARGON GAS DUAL TEMPERED GLAZING FRONT ENTRY DOOR FOR UNITS 2, 3, 41 7/8" 10'-6" HEADER 5'-6"6'-0" FIXED9'-0"2'-0" 5'-0"6'-0"HORIZONTAL SLIDER 8'-0" 8'-0" 9'-0"9'-0" HEADER HEIGHT TRANSOM WINDOW 10'-6" HEADER HEIGHT TRANSOM WINDOW 9'-0" HEADER EGRESS YES YES YES NO NO NO NO NO NO NO NO NO NO WINDOW NOTESDOOR NOTES 1.)PROVIDE ALUMINUM THRESHOLD & WEATHER STRIPPING AT ALL EXTERIOR DOORS, TYP. 2.)UNDERCUT DOOR FOR VENTILATION 3.)SLIDING PATIO DOOR TO BE 'MILGARD®' VINYL PATIO DOOR, MONTECITO® SERIES. EXTERIOR COLOR: TAN, INTERIOR COLOR: WHITE. 4.)SWING PATIO DOOR TO BE 'PELLA' ARCHITECT SERIES ALUMINUM CLAD DOOR, EXT. COLOR: BROWN, INT. COLOR: WHITE. 5.)ALL INTERIOR DOOR TO BE "JELDWEN" ALL PANEL INTERIOR WOOD DOOR - 2 RECESSED PANEL W/ PAINT OR EQUAL 6.) PROVIDE 100 SQ. IN. MIN. OF LOUVERED VENTILATION. 7.)ALL DOORS SHALL MEET OR EXCEED THE FOLLOWING ENERGY PERFORMANCE RATINGS: A.) U-FACTOR OF LESS THAN OR EQUAL TO 0.28 (PER ENERGY CALCS.) B.) SOLAR HEAT GAIN COEFFICIENT (SHGC) OF LESS THAN OR EQUAL TO 0.18 (PER ENERGY CALCS.) 8.)PROVIDE GARAGE DOOR OPENER: CHAMBERLIN C273 OR EQUAL (PROVIDE POWER) NOTES TEMPERED NOTES PAINTED WOOD1 3/8"2'-8"SINGLE SWING WOOD S.C. PAINTED WOOD1 3/8"2'-6"SINGLE SWING WOOD S.C. PAINTED VINYL PAINTED WOOD1 3/8"2'-6"SINGLE SWING WOOD S.C. 1.)ALL WINDOWS TO HAVE 8'-0 HEADER HEIGHT, UNLESS NOTED OTHERWISE. 2.)ALL EGRESS WINDOWS SHALL HAVE: A.)SILLS NOT TO EXCEED 44" IN HEIGHT, TYP. B.)OPENABLE AREA W/ 20" MIN. CLEAR WIDTH & 36" MIN. CLEAR HEIGHT OR OPENABLE AREA W/ 30" MIN. CLEAR WIDTH & 24" MIN. CLEAR HEIGHT C.)OPENABLE AREA TO BE THE FOLLOWING: I.)5.0 SF MINIMUM @ 1ST FLOOR II.)5.7 SF MINIMUM @ 2ND FLOOR 3.)IF LESS THAN 60" ABOVE STANDING SURFACE AND DRAIN INLET, GLAZING IN WINDOWS AT SHOWERS & TUBS SHALL BE TEMPERED. 4.)ALL WINDOWS SHALL MEET OR EXCEED THE FOLLOWING ENERGY PERFORMANCE RATINGS: A.) U-FACTOR OF LESS THAN OR EQUAL TO 0.28 (PER ENERGY CALCS.) B.) SOLAR HEAT GAIN COEFFICIENT (SHGC) OF LESS THAN OR EQUAL TO 0.18 (PER ENERGY CALCS.) 5.)WITHIN 24 INCHES OF A DOOR, SHALL BE TEMPERED. PER CRC 308.4. 6.) GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS WHERE THE BOTTOM EXPOSED EDGE IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE A STANDING OR WALKING SURFACE SHALL BE TEMPERED. 7.)GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36 INCHES HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE GLAZING IS LESS THAN 60 INCHES ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE SHALL BE TEMPERED. 1, 8 1 1, 4, 7 1, 3, 7 1, 3, 7 PAINTED WOOD1 3/8"2'-8"SINGLE SWING WOOD S.C. 6 7 8 9 10 11 12 13 4'-0"PAIR PAINTED WOOD1 1/2" SLIDING CLOSET DOOR (XO) 5 5 2 RECESSED PANEL 2 RECESSED PANEL 2 RECESSED PANEL 2 RECESSED PANEL 2 RECESSED PANEL 2 RECESSED PANEL 2 , 5 , 6 2 , 5 5 5 5 7'-0" HEADER HEIGHT 7'-0" HEADER HEIGHT NO YES 6 YES 5 T T NO NO T YES 5 T YES YES 6 6 T T T YES 7 NO 6'-6" HEADER HEIGHTNO NO NO 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0"FOR UNIT A STAIR LANDING WINDOW: 7'-0" HEADER HEIGHT PAINTED WOOD1 1/2"2'-8"SINGLE SWING WOOD S.C. 2 RECESSED PANEL 16'-8"20 MIN. FIRE RATED DOOR. SELF CLOSING AND SELF LATCHING FINISH FLOOR LINE 8'-0" HEADER 7'-0" HEADER 6 7 8 9 10 11 12 13 FACTORY WINDOW / DOOR SCHEDULE A8.1 1 1 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update BATT INSULAITON PER ENERGY CALCUATIONS WATERPROOFING PAPER. 3/4" MIN GYPCRETE O/ 3/4" PLYWD SHEATHING. REFER TO STRUCT DWG WD FLOOR FRAMING. REFER TO STRUCTURAL DWG. 5/8" TYPE 'X' GYP BD, 7/8" EXT PLASTER O/ MTL LATH & 15 LBS FELT UNDERLAYMENT (PROVIDE 30 LBS FELT UNDERLAYMENT WHEN APPLYING O/ PLYWD SHEAR PANELS, WHERE OCCURS) 2X ROOF RAFTER PER STRUCT DWG ASPHALT ROOFING O/ BLDG. MEMBRANE O/ CORNER ADHESIVE MEMBRANE 5/8" TYPE 'X' GYP BD 5/8" TYPE 'X' GYP BD 5/8" TYPE 'X' GYP BD 8" CMU BLOCK WALL, SOLID GROUTED. REFER TO STRUCT DWG DBL 2X TOP PLATE. REFER TO STRUCT DWG BATT INSULATION PER ENERGY CALCULATIONS 7/8" EXT PLASTER O/ MTL LATH & 15 LBS FELT UNDERLAYMENT (PROVIDE 30 LBS FELT UNDERLAYMENT WHEN APPLYING O/ PLYWD SHEAR PANELS, WHERE OCCURS) WATERPROOFING PAPER. PROVIDE FIREBLOCKING, TYP. 5/8" TYPE 'X' GYP BD IN ATTIC SPACE PROVIDE FIREBLOCKING, TYP. 2X OR 3X P.T. SILL PLATE. REFER TO STRUCT DWG 7/8" EXT PLASTER O/ MTL LATH & 15 LBS FELT UNDERLAYMENT (PROVIDE 30 LBS FELT UNDERLAYMENT WHEN APPLYING O/ PLYWD SHEAR PANELS, WHERE OCCURS) BATT INSULATION PER ENERGY CALCULATIONS DBL 2X TOP PLATE. REFER TO STRUCT DWG WD FLOOR FRAMING. REFER TO STRUCTURAL DWG. 3/4" MIN GYPCRETE O/ 3/4" PLYWD SHEATHING. REFER TO STRUCT DWG WATERPROOFING PAPER. PROVIDE FIREBLOCKING, TYP. 2X OR 3X P.T. SILL PLATE. REFER TO STRUCT DWG AMICO E.J. SCREED #XJ15 OR EQUAL 2X OR 3X P.T. SILL PLATE. REFER TO STRUCT DWG 5/8" TYPE 'X' GYP BD, BATT INSULATION PER ENERGY CALCULATIONS PROVIDE FIREBLOCKING, TYP. FIRE-RATED EXTERIOR WALL AT 1ST FLR 1 1/2"=1'-0" FIRE-RATED EXTERIOR WALL AT 2ND FLR 1 1/2"=1'-0" FIRE-RATED EXT WALL /CEILING /ROOF RAKE 1 1/2"=1'-0" BATT INSULAITON PER ENERGY CALCUATIONS MTL. EDGE FLASHING 6" BARGEBOARD "J" MOLDING STUCOO TERMINATION AMICO E.J. SCREED #XJ15 OR EQUAL AMICO E.J. SCREED #XJ15 OR EQUAL FIRE-RATED WOOD DECK 1 1/2"=1'-0" MIN. 28-MIL WEATHERWEAR FINISH TOPPING AS PER DEX-O-TEX MIN.150-MIL WATERPROOF LATEX MEMBRANE (FABRIC REINFORCED) AS PER DEX-O-TEX MIN. 50-MIL LIQUID APPLIED WATERPROOFING MEMBRANE (NEOBOND II) AS PER DEX-O-TEX TYPE IV ASPHALT-COATED FIBERGLASS BASE SHEET AS PER DEX-O-TEX. PLYWOOD SHEATHING PER STRUCTURAL DESIGN 2X FLOOR JOIST PER STRUCTURAL DESIGN (FRAME OR RIP TO SLOPE FOR DRAINAGE PER PLAN) 7/8" CEMENT PLASTER ON THE EXTERIOR SURFACE O/ PAPER- BACKED GALV. METAL LATH O/ MOISTURE- BARRIER O/ 30# BLDG PAPER (PROVIDE E.J. NOT TO EXCEED 144 SQ FT. MAX.) 1-HOUR FIRE RATED FLOOR ASSEMBLY W/ CLASS A FIRE-RATING PER ICC-ESR1757 NOTE: PROVIDE E.J. at DECKING PER MFR. REQUIREMENTS WATERPROOFING AT RETAINING WALL FOOTING 1 1/2" = 1'-0" CONC. RETAINING WALL (SEE STRUCT. DWG.) COMPOSITE DRAINAGE BOARD W/ GEOTEXTILE FILTER FABRIC O/ MIN. 60MIL LIQUID-APPLIED WATER- PROOFING MEMBRANE - INSTALL PER MANUFACTURER'S SPECS GEOTEXTILE FABRIC AND GRAVEL POCKET - CONST. PER MANUF. SPECS. PERFORATED DRAINAGE PIPE - SLOPE TO DRAIN PER PLUMBING NON-EXPANSIVE GRANULAR FILL PER STRUCT. CONT. BENTONITE WATERSTOP - INSTALL PER MANUF. SPECS CONCRETE WALL (SEE STRUCT. DWG.)CONT. BENTONITE WATERSTOP - INSTALL PER MANUF. SPECS WATERPROOFING AT RETAINING WALL FOOTING 1 1/2" = 1'-0" 3" C L R . MI N .24" MIN. 24 " L A P N . T . S . 12 " 6" MI N . CMU FENCE WALL 1 1/2" = 1'-0" PE R E L E V A T I O N FINISH GRADE #4 HORIZ. @ 32" O.C. O/ FULL HT. OF WALL #4 DOWEL @ 32" O.C. 2-#4 HORIZ. CONT. #4 VERT. @ 32 O.C. IN SOLID GROUTED OF ALL WALL CELLS. 6X8X16 PRECISION CMU BLOCK BY 'ANGELUS BLOCK CO. INC.' SLOPED CAP BLK. 7/8" CEMENT PLASTER O/ MTL. LATH w/ BASE SCREED (EXTERIOR PLASTER O/ BOTH SIDES AND TOP OF BLOCK WALL) 2" C L R . 1/2" RADIUS TYP. T.O. CURB AT 1" A.F. GRADE AT TURF T.O. CURB AT 2" A.F. GRADE AT PLANTING AREA. THICKENED EDGE AT EXT. SLAB W/ #4 REBAR CONT. 1/4" WIDE CONTROL JOINT W/ 1/4" RADIUS EDGE 4" CONC. SLAB at WALKWAYS w/ LIGHT BROOM FINISHED SLOPE 1/4" PER FOOT TO DRAIN REBAR, PER STRUCTURAL 2" MIN. SANDBED O/ 6 MIL. VAPOR BARRIER 0/ 95% COMPACTED SUB-GRADE. 1 1 / 2 " EXTERIOR CONCRETE SLAB 1 1/2" = 1'-0" 5" CONC. SLAB at DRIVEWAY AND GARAGE FLOOR w/ LIGHT BROOM FINISHED SLOPE 1/4" PER FOOT TO DRAIN 02 8 4 0 - 1 7 TYPICAL CONCRETE WALL DETAIL 1 1/2"=1'-0" 8" CONCRETE WALL PER STRUCTURAL DRAWINGS. REFER TO STRUCTURAL DRAWINGS FOR SIZE, REINFORCING AND OTHER CONSTRUCTION DETAILS. MIN. 4-HOUR FIRE RATED EXTERIOR AND INTERIOR WALL PER C.B.C. TABLE 720.1(2) 7/8" EXT. PLASTER O/ W.P. PAPER BACKED MTL. LATH PLAN VIEW CONC. SLAB PRE-CAST TRENCH DRAIN CAST IRON GRATING, SIZE PER GEADING 4" CONC. ALL AROUND TRENCH DRAIN 1 1/2" = 1'-0" REBAR, PER STRUCTURAL SLOPE to DRAIN APPLICABLE STANDARDS: Complies w/ ASTM C 665 Type I. Is noncombustible, meeting test criteria of ASTM E 136. Thermal performance determined by ASTM C 653 and C 518. NOTES: FIRE & SOUND RATING VALUES PER CERTAINTEED CORPORATION. APPLY O/ PLYWD WHERE OCCURS. TYP. 1-HR. PARTY WALL @ WOOD CEILING 1 1/2" = 1'-0" 1-LAYER 5/8" GYP. BD. @ CEILING DBL. R-13 3 1/2" THK. APPROVED INSULATION TYP. AT EA. WALL TO ACHIEVE STC 58 MIN. 1" AIR SPACE TYP. 5/8" TYPE 'X' GYP. BD. EA. SIDE EXTEND TO BOTTOM OF PLYWOOD BATT INSULATION PER ENERGY CALCULATIONS R13 BATT INSULATION VERTICAL FIRESTOP AT 8'-0" MAX TYP 2X FLOOR/CEILING JOIST PER STRUCT. PROVIDE 4" MIN. HORIZONTAL FIBER-GLASS FIRESTOP @ TOP & BOT. PLATE @ 10'-0" O.C. MAX. NOTE: PROVIDE VERTICAL FIRESTOPS AT PARALLEL VERT. STUDS @ 8'-0" O.C. MAX. APPLICABLE STANDARDS: Complies w/ ASTM C 665 Type I. Is noncombustible, meeting test criteria of ASTM E 136. Thermal performance determined by ASTM C 653 and C 518. NOTE: FIRE & SOUND RATING VALUES PER CERTAINTEED CORPORATION. APPLY O/ PLYWD WHERE OCCURS. TYP. 1-HR. PARTY WALL @ WOOD FLOOR 1 1/2" = 1'-0" 1-LAYER 5/8" GYP. BD. @ CEILING 1" AIR SPACE TYP. 5/8" TYPE 'X' GYP. BD. EA. SIDE EXTEND TO BOTTOM OF PLYWOOD 3/4" MIN GYPCRETE O/ 3/4" PLYWD SHEATHING PER STRUCT.BATT INSULATION PER ENERGY CALCULATIONS R13 BATT INSULATION VERTICAL FIRESTOP AT 8'-0" MAX TYP 2X FLOOR/CEILING JOIST PER STRUCT. PROVIDE 4" HORIZONTAL FIBER-GLASS FIRESTOP @ TOP & BOT. PLATE @ 10'-0" O.C. MAX. DBL. R-13 3 1/2" THK. APPROVED INSULATION TYP. AT EA. WALL TO ACHIEVE STC 58 MIN. NOTE: PROVIDE VERTICAL FIRESTOPS AT PARALLEL VERT. STUDS @ 8'-0" O.C. MAX. TYP. 1-HR. PARTY WALL AT ROOF 1 1/2" = 1'-0" 1" AIR SPACE TYP. 5/8" TYP 'X' GYP BD EACH SIDE)(GA FILE WP3820 SIMILAR W/ 1 LAYER BATT INSULATION PER ENERGY CALCULATIONS 1-LAYER 5/8" GYP. BD. @ CEILING ASPHALT ROOF TILE O/ WATERPROOFING O/ PLYWD. SHEATHING PER STRUCT. ROOF FRAMING PER STRUCT. W/ SOLID BKL @ 1" AIR SPACE. PROVIDE 4" HORIZONTAL FIBER-GLASS FIRESTOP @ TOP & BOT. PLATE @ 10'-0" O.C. MAX. 5/8" TYPE 'X' GYP. BD. EA. SIDE EXTEND TO BOTTOM OF PLYWOOD NOTE: PROVIDE VERTICAL FIRESTOPS @ 8'-0" O.C. MAX. DBL. R-13 3 1/2" THK. APPROVED INSULATION TYP. AT EA. WALL TO ACHIEVE STC 58 MIN. NOTE: PROVIDE VERTICAL FIRESTOPS AT PARALLEL VERT. STUDS @ 8'-0" O.C. MAX. 2nd FLOOR ASSEMBLY, TYP. 3" = 1'-0" FINISH FLOORING, RE: A1.1 PLYWOOD SHEATHING per STRUCTURAL DESIGN FLOOR JOIST FRAMING per STRUCTURAL 2x WOOD STUB WALL FRAMING, RE: STRUCTURAL DISCIPLINE 12'-3" FIN. FLOOR NOISEPROOFING JOIST TAPE (3" GREEN GLUE or EQUAL) 10 " M I N . 6" M A X . PAVING PER PLAN NOTES: 1. PROVIDE EXPANSION JOINTS AT 25'-0" O.C. MAX. AND CURVES, TANGENTS AND CORNERS. 2. CONTINUE REBAR THROUGH EXPANSION JOINTS 3. BASE OF CURB TO BE SET ON COMPACTED SUB-GRADE 4. TOOL FINISH ALL EXPOSED CONC. SURFACES. 1/2" RADIUS TYP. AT EXPOSED EDGE PLANTING AREA 4" GRAVEL BASE WEAKENED PLATE JOINT AT 15'-0" O.C. MAX. #4 CONT. TOP AND BOTTOM 6" 1/4" SLOPE 4" M I N . CONCRETE CURB AND PLANTER 1 1/2" = 1'-0" 4" U. N . O . COLOR AND FINISH) (SEE PLANS FOR CONCRETE PAVING 1/8" H/ 4 COMPACTED SUBGRADE SAWCUT CONTROL JOINT@ CONCRETE 3" = 1'-0" REBAR, PER STRUCTURAL SAW CUT CONTROL JOINTS SHALL OCCUR MID POINT BETWEEN EXPANSION JOINT - E.J., SEE DETAIL 2/AD1 and PLAN 24" MIN. 20 " L A P 1' - 0 " M I N . 3" C L R . MI N . 1' - 0 " PROJECT SIDE 6' - 0 " M A X . 'ANGELES' 6"X8"X16" STANDARD PRECISION BLOCK, STACK BOND. 2-#4 HORIZ. @ CONC. FTG. FINISH GRADE 2" SLOPED CMU CAP BLK. SEE STRUCTURAL for REBAR NEIGHBOR SIDE 2-#4 CONT. PL CMU FENCE WALL AT PROPERTY LINE 1" = 1'-0" EXTERIOR PLASTER O/ ENTIRE SIDES AND TOP OF BLOCK WALL. #4 DOWEL @ 32" O.C. #4 VERT. @ 32 O.C. IN SOLID GROUTED OF WALL CELLS.7/8" CEMENT PLASTER O/ MTL. LATH w/ BASE SCREED 2" C L R . 1/2" RADIUS BACKER ROD DIRECTLY BELOW SEALANT EXPANSION JOINT LOCATED at 10'-0" MAX., USE "KOLD SEAL ZIPPER STRIP" OR EQ., W/ 3/4" THK. BEAD OF JOINT SEALANT O/ SEALANT COLOR TO MATCH CONC. EXT. CONC. PAVING EXPANSION JOINT 3" = 1'-0" 4" CONC. SLAB at WALKWAYS w/ LIGHT BROOM FINISHED SLOPE 1/4" PER FOOT TO DRAIN 5" CONC. SLAB at DRIVEWAY AND GARAGE FLOOR w/ LIGHT BROOM FINISHED SLOPE 1/4" PER FOOT TO DRAIN REBAR, PER STRUCTURAL DETAILS AD1 3 4 6 7 5 101418 20 16 12 2 91317 19 15 11 1 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update APPLICABLE STANDARDS: Complies w/ ASTM C 665 Type I. Is noncombustible, meeting test criteria of ASTM E 136. Thermal performance determined by ASTM C 653 and C 518. NOTES: FIRE & SOUND RATING VALUES PER CERTAINTEED CORPORATION. APPLY O/ PLYWD WHERE OCCURS. 1-HR. PARTY WALL @ GARAGE CEILING 1 1/2" = 1'-0" 1-LAYER 5/8" TYPE 'X' GYP. BD. @ CEILING 3/4" MIN GYPCRETE O/ 3/4" PLYWD SHEATHING PER STRUCT. BATT INSULATION PER ENERGY CALCULATIONS R13 BATT INSULATION VERTICAL FIRESTOP AT 8'-0" MAX TYP 2X FLOOR/CEILING JOIST PER STRUCT. SINGLE LAYER 5/8" TYPE 'X' GYP BD ON EA SIDE TO ACHEIVE 1-HR FIRE RATING. SEE PLANS FOR LOCATION FIRE SAFING - MINERAL WOOL CONT. DBL. R-13 3 1/2" THK. APPROVED INSULATION TYP. AT EA. WALL TO ACHIEVE STC 58 MIN. NOTE: PROVIDE VERTICAL FIRESTOPS AT PARALLEL VERT. STUDS @ 8'-0" O.C. MAX. NOT USED HARDIE BOARD & BATTEN OUTSIDE CORNER 3" = 1'-0" HARDIE BOARD-N-BATTTEN SIDING INSTALLED PER MANUF. INSTRUCTIONS O/ CONT. HAT CHANNEL AND 15 LBS. FELT UNDERLAYMENT (PROVIDE 30 LBS. FELT UNDERLAYMENT WHERE APPYING O/ PLYWOOD SHEAR PANELS WHERE OCCURS) STUD WALL, SEE STRUCTURAL LEAVE APPROPRIATE GAP AND CAULK LEAVE APPROPRIATE GAP AND CAULK VERT. HARDIE-TRIM BOARDSPLAN FULLY INSULATE ALL CAVITIES 07 6 2 0 - 0 1 EXTERIOR PLASTER REVEAL 3" = 1'-0" 1/ 2 " 2X4 BLK'G 2X6 WD STUDS PER STRUCT. DWG 5/8" GYP. BD. R-21 BATT INSULATION 7/8" EXT. PLASTER O/ W.P.PAPER-BACKED MTL. LATH O/ WEATHER-RESISTANT BARRIER 3" L A P PLYWD SHEATHING, SEE STRUCTURAL GALVANIZED METAL PLASTERJOINT - AMICO #XJ15 or EQUAL,(AREA NOT TO EXCEED 144 SQ.FT.),SEE ELEVATIONS FOR LOCATIONS 06 0 0 0 - 0 1 c EXT WALL HOR. SIDING BUTTING STUCCO 3" = 1'-0" 5/8" TYPE 'X' GYP. BD. 2X WD. STUDS @ 16" O.C. R-21 BATT INSULATIONNOTE: FOR MATERIAL COLOR AND FINISH, SEE EXTERIOR ELEVATIONS. HARDIEPLANK SIDING SEALANT 1" THCK X 3.5" W HARDIETRIM BOARD 7/8" EXT. PLASTER O/ MTL. LATH AND 15 LBS. FELT UNDERLAYMENT (PROVIDE 30 LBS. FELT UNDERLAYMENT WHERE APPYING O/ PLYWOOD SHEAR PANELS WHERE OCCURS) "J" MTL. CHANNEL SEALANT PLAN 1 1/2" W X 3/4" THK HARDIETRIM BATTEN BOARDS SPACED @ 12" O.C. EXTERIOR WALL (BOARD AND BATTEN) 3" = 1'-0" R-21 BATT INSULATION 5/8" GYP. BD. OVER 2X FRAMING. 2X WD. STUDS @ 16" O.C. PLYWOOD SHEATHING PER STRUCTURAL, WHERE OCCURS 5/16" THK HARDIEPANEL O/ 15 LBS. FELT UNDERLAYMENT (PROVIDE 30 LBS. FELT UNDERLAYMENT WHERE APPYING O/ PLYWOOD SHEAR PANELS WHERE OCCURS) NOTE: INSTALL JAMESHARDIE PRODUCTS PER MANUFACTURER SPECIFICATIONS AND INSTRUCTIONS. PLAN EXTERIOR WALL (HORIZONTAL SIDING) 3" = 1'-0" HARDIEPLANK SIDING, 6" EXPOSURE NOTE: INSTALL PER MANUFACTURER SPECIFICATIONS AND INSTRUCTIONS. 15 LBS. FELT UNDERLAYMENT (PROVIDE 30 LBS. FELT UNDERLAYMENT WHERE APPYING O/ PLYWOOD SHEAR PANELS WHERE OCCURS) MIN. 1 1/4" OVERLAP PLYWOOD SHEATHING PER STRUCTURAL, WHERE OCCURS R-21 BATT INSULATION 2X WOOD FRAMING 5/8" THK. GYP. BD. 7/8" EXT. PLASTER O/ MTL. LATH AND 15 LBS. FELT UNDERLAYMENT (PROVIDE 30 LBS. FELT UNDERLAYMENT WHERE APPYING O/ PLYWOOD SHEAR PANELS WHERE OCCURS) EXTERIOR WALL (EXTERIOR PLASTER) 3" = 1'-0" R-21 BATT INSULATION 5/8" GYP. BD. OVER 2X FRAMING. 2X WD. STUDS @ 16" O.C. PLYWOOD SHEATHING PER STRUCTURAL, WHERE OCCURS PLAN 3" LAP GALVANIZED METAL PLASTER JOINT AMICO #XJ15 or EQUAL, (AREA NOT TO EXCEED 144 SQ.FT.), SEE ELEVATIONS FOR LOCATIONS 06 0 0 0 - 0 1 c EXT WALL BOARD & BATTEN BUTTING STUCCO 3" = 1'-0" 5/8" TYPE 'X' GYP. BD. 2X WD. STUDS @ 16" O.C. R-21 BATT INSULATION 7/8" EXT. PLASTER O/ MTL. LATH AND 15 LBS. FELT UNDERLAYMENT (PROVIDE 30 LBS. FELT UNDERLAYMENT WHERE APPYING O/ PLYWOOD SHEAR PANELS WHERE OCCURS) 1" THCK X 2.5" W HARDIETRIM BOARD NOTE: FOR MATERIAL COLOR AND FINISH, SEE EXTERIOR ELEVATIONS. "J" MTL. CHANNEL SEALANT HARDIEPANEL AND HARDIETRIM BATTEN BOARDS SEALANT PLAN EXT. PLASTER TO EXT. PLASTER OVERHANG 1 1/2" = 1'-0" 7/8" EXT. PLASTER O/ PAPER-BACKED MTL. LATH O/ WEATHER-RESISTANT BARRIER FRAMING PER PLANS EXT. PLASTER CORNER BEAD 5/8" GYPSUM BOARD BATT INSULATION PER ENERGY CALCULATIONS 7/8" EXT. PLASTER O/ PAPER-BACKED MTL. LATH O/ WEATHER-RESISTANT BARRIER OVERHANG PER PLAN HE I G H T P E R S E C T I O N EXT. PLASTER TOBOARD AND BATTEN OVERHANG 1 1/2" = 1'-0" HARDIEPANEL BOARD AND BATTEN SIDING O/ FELT UNDERLAYMENT O/ PLYWD SHEATHING PER STRUCT. FRAMING PER PLANS EXT. PLASTER CORNER BEAD 5/8" GYPSUM BOARD BATT INSULATION PER ENERGY CALCULATIONS 7/8" EXT. PLASTER O/ PAPER-BACKED MTL. LATH O/ WEATHER-RESISTANT BARRIER OVERHANG PER PLAN HE I G H T P E R S E C T I O N EXT. PLASTER CASING BEAD BACKER ROD AND SEALANT HARDIETRIM BOARD, 3.5" WIDTH, 4/4 SMOOTH FINISH. BOARD AND BATTEN TOEXT. PLASTER OVERHANG 1 1/2" = 1'-0" FRAMING PER PLANS HARDIETRIM BOARD, 3.5" WIDTH, 4/4 SMOOTH FINISH. 5/8" GYPSUM BOARD BATT INSULATION PER ENERGY CALCULATIONS OVERHANG PER PLAN HE I G H T P E R S E C T I O N EXT. PLASTER CASING BEAD BACKER ROD AND SEALANT BACKER ROD AND SEALANT 7/8" EXT. PLASTER O/ PAPER-BACKED MTL. LATH O/ WEATHER-RESISTANT BARRIER HARDIEPANEL BOARD AND BATTEN SIDING O/ FELT UNDERLAYMENT O/ PLYWD SHEATHING PER STRUCT. HARDIEPANEL BOARD AND BATTEN SIDING O/ FELT UNDERLAYMENT O/ PLYWD SHEATHING PER STRUCT. LAP AND CONTINUE WEATHER-RESISTANT BARRIER 6" LA PEXT. PLASTER GALVANIZED 'Z' FLASHING (DO NOT CAULK) 7/8" EXTERIOR PLASTER w/ "J" MOLD O/ PAPER BACKED MTL. LATH & BLDG. PAPER SLOPE BALCONY EDGE 3" = 1'-0" WOOD RIM JOIST OR BEAM PER STRUCTURAL DEX-O-TEX WEATHER WEAR DECK SURFACING O/ W.P. BLDG. MEMBRANE WRAP O/ DBL. BLOCKING 1/4" METAL PLATE w/ POST, O/ 1/2" EXT.PLY. & BLDG. PAPER, SEE DETAIL 17/AD2 2"X6" WOOD RAILING, PAINTED. DBL. 2x WOOD O/ VERT. METAL POST w/ SCREW at 12" O.C. PROVIDE SELF-ADHESIVE WRAP AT PLYWOOD DECK OVER BEAM EXT. PLYWOOD DECK, SEE STRUCTURAL DRWGS. 22 GA GALVANIZED SHEET METAL FLASHING 1 1 / 2 " BALCONY FLOOR ASSEMBLY, TYP. 3" = 1'-0" 2x FLOOR JOIST PER STRUCTURAL DESIGN (FRAME OR RIP TO SLOPE FOR DRAINAGE PER PLAN) TYPE IV ASPHALT-COATED FIBERGLASS BASE SHEET AS PER DEX-O-TEX MIN. 50-MIL LIQUID APPLIED WATERPROOFING MEMBRANE (NEOBOND II) AS PER DEX-O-TEX MIN. 150-MIL WATERPROOF LATEX MEMBRANE (FABRIC REINFORCED) AS PER DEX-O-TEX MIN. 28-MIL WEATHERWEAR FINISH TOPPING AS PER DEX-O-TEX PLYWOOD SHEATHING PER STRUCTURAL DESIGN 7/8" CEMENT PLASTER ON THE EXTERIOR SURFACE W/ PLASTER MIX 1:4 FOR SCRATCH COAT AND 1:5 FOR BROWN COAT, BY VOLUME, CEMENT TO SAND O/ PAPER- BACKED GALV. METAL LATH O/ MOISTURE- BARRIER O/ 30# BLDG PAPER 1-HOUR FIRE RATED FLOOR ASSEMBLY W/ CLASS A FIRE-RATING PER ICC-ES ESR-1757 BALCONY GUARDRAIL DETAIL 3/4" = 1'-0" 3' - 6 " 1" TY P . 12 " 2 1 / 2 " 8" 1 1/2"1 1/2" 1 1 / 2 " SHAPE DBL. VERT. WOOD POSTS, PAINTED PLAN VIEW 2"x2"x1/8" STL. TUBE, PAINTED 2"x6" WOOD RAILING, PAINTED 2x WOOD VERT. SCREW at 12" O.C. VERT (4) 3/8"x2 1/2" G.I. LAG BOLTS 2"x2"x1/8" STL. TUBE. WELDED to 1/4" THICK PLATE 2x WD TOP RAIL, USE (2) #10 x 2 1/2" STAR DECK SCREWS at EACH POST ATTACH 2x6" RAILING w/ (2) #10x 2 1/2" STAR HEAD DECK SCREWS TO VERT. POST AFTER POST INSTALLATION, WOOD RAILING, PAINTED. POST and PLATE 1'- 4 3 / 8 " 5 1 / 2 " 2x WD 4' - 9 1 / 2 " S T E E L P O S T 18 AD2 1/4" 1 1 / 2 " DEX-O-TEX DEX-O-TEX O/ MEMBRANE WATERPROOFING 7/8" CEMENT PLASTER O/ METAL LATH O/ WATERPROOFING MEMBRANEGALVANIZED, PROVIDE "J" MOLDING END FLASHING EXTERIOR DECK FINISHES N.T.S. 22 GA GALVANIZED SHEET METAL FLASHING SELF-ADHESIVE MEMBRANE WRAP 3" 4" EXT. PLYWOOD DECK, SEE STRUCT'L FRAMING, SEE STRUCT'L CONCRETE WALL, SEE STRUCT'L CONCRETE WALKWAY, SEE SITE PLAN E.J. 26 GA. SHEET METAL 'L' SHAPED BASE FLASHING. FRAMING PER STRUCT. DWG. CROSSFIELD PRODUCTS dex o tex DEX-O-TEX WEATHERWEAR AT WOOD FRAMED BALCONY & STUD WALL 3" = 1'-0" BATT INSULATION 2X P.T. SILL PLATE 3" 6" M I N . 6" MIN. EXT. PLYWD. SHEATHINGWHERE OCCURS DEX-O-TEX 'ELASTATEX 500'DECK FINISH LAP UP ATWALL BASE FLASHING SLOPE 1/4" PER 1'-0" TO DRAIN SELF ADHESIVE FLASHING 2" CORROSION RESISTANTWEEP SCREED EXT. PLASTER FINISHES,SEE ELEVATIONS 7/8" EXT. PLASTER O/ PAPER BACKED METAL LATH O/ 2X FRAMING INTERIOR WALL FINISHES, SEE SECTIONS THIN-SET CONC. FLOORING w/ FINISHES, PER OWNER NOTE: DEX-O-TEX OVER FLASHING PRIOR TO STUCCO EXT. WALL TO FLOOR 1 1/2" = 1'-0" INTERIOR FINISH PER PLAN PLYWD. SUB-FLOOR PER STRUCT. BATT INSULATION AS REQUIRED. BATT INSULATION AS REQUIRED. 5/8" GYPSUM BOARD HARDIE PANEL AND HARDIETRIM BATTEN BOARD O/ WEATHER-RESISTANT BARRIER 5/8" G.W.B. O/ 2X FLOOR JOIST SEALANT AND BACKER ROD 1" THCK X 3.5" W HARDIETRIM BOARD CASING BEAD 7/8" EXT. PLASTER w/ CASING BEAD O/ PAPER-BACKED METAL LATH O/ WEATHER RESISTANT BARRIER HARDIEPLANK SIDING O/ FELT UNDERLAYMENT O/ PLYWD SHEATHING PER STRUCTURAL HARDIETRIM WINDOW TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH 11 AD2 'Z' FLASHINGSIM. EXT. WALL TO FLOOR 1 1/2" = 1'-0" BATT INSULATION AS REQUIRED. HARDIEPLANK SIDING O/ FELT UNDERLAYMENT O/ PLYWD SHEATHING PER STRUCT. HARDIETRIM WINDOW TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH SEALANT AND BACKER ROD 7/8" EXT. PLASTER O/ PAPER-BACKED MTL. LATH O/ WEATHER-RESISTANT BARRIER BATT INSULATION AS REQUIRED. INT. FINISH O/ 3/4 " THCK GYPCRETE O/ PLYWOOD SHEATHING PER STRUCT. 5/8" G.W.B. O/ FRAMING BATT INSULATION AS REQUIRED. EXT. WALL TO FLOOR 1 1/2" = 1'-0" BATT INSULATION AS REQUIRED. HARDIEPANEL BOARD AND BATTEN SIDING O/ FELT UNDERLAYMENT O/ PLYWD SHEATHING O/ FRAMING PER STRUCTURAL DISCIPLINE HARDIETRIM WINDOW TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH SEALANT AND BACKER ROD 5/8" GYP. BOARD BATT INSULATION AS REQUIRED. INT. FINISH O/ 3/4 " THCK GYPCRETE O/ PLYWOOD SHEATHING PER STRUCT. 5/8" G.W.B. O/ FRAMING EXT. WALL TO FLOOR 1 1/2" = 1'-0" BATT INSULATION AS REQUIRED. HARDIEPANEL BOARD AND BATTEN SIDING O/ FELT UNDERLAYMENT O/ PLYWD SHEATHING PER STRUCT. HARDIETRIM WINDOW TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH EXT. GALVANIZED PLASTER CASING BEAD 7/8" EXT. PLASTER O/ PAPER-BACKED MTL. LATH O/ WEATHER-RESISTANT BARRIER 5/8" GYP. BOARD O/ FRAMING BATT INSULATION AS REQUIRED. INT. FINISH O/ 3/4 " THCK GYPCRETE O/ PLYWOOD SHEATHING PER STRUCT. 6" LA P 7/8" EXT. PLASTER O/ PAPER-BACKED MTL. LATH O/ WEATHER-RESISTANT BARRIER BATT INSULATION AS REQUIRED. LAP AND CONTINUE WEATHER-RESISTANT BARRIER 6" LA P EXT. PLASTER GALVANIZED 'Z' FLASHING (DO NOT CAULK) LAP AND CONTINUE WEATHER-RESISTANT BARRIER BATT INSULATION AS REQUIRED. LAP AND CONTINUE WEATHER-RESISTANT BARRIER 6" LA P SEALANT AND BACKER ROD 5/8" GYP. BOARD O/ FRAMING 5/8" GYP. BOARD O/ FRAMING EXT. PLASTER GALVANIZED 'Z' FLASHING (DO NOT CAULK) EXT. PLASTER GALVANIZED 'Z' FLASHING (DO NOT CAULK) 3 4 DETAILS AD2 6 7 8 5 101418 20 16 12 2 91317 19 15 11 1 Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update HARDI LAP SIDING @ OUTSIDE CORNER 3" = 1'-0" HARDI-PLANK LAP SIDING INSTALLED PER MANUF. INSTRUCTIONS O/ CONT. HAT CHANNEL AND 15 LBS. FELT UNDERLAYMENT (PROVIDE 30 LBS. FELT UNDERLAYMENT WHERE APPYING O/ PLYWOOD SHEAR PANELS WHERE OCCURS) STUD WALL, SEE STRUCTURAL LEAVE APPROPRIATE GAP AND CAULK LEAVE APPROPRIATE GAP AND CAULK VERT. HARDI-TRIM BOARDSPLAN FULLY INSULATE ALL CAVITIES HEADER PER STRUCT. 7/8" EXT. PLASTER O/ MTL. LATH AND FELT UNDERLAYMENT O/PLYWD SHEATHING PER STRUCT. MESH SCREEN 7/8" EXT. PLASTER O/ MTL. LATH AND FELT UNDERLAYMENT O/PLYWD SHEATHING PER STRUCT. 2X FRAMING PER STRUCT. LINE OF JAMB (BEYOND) WD. SHIM OR FILLER AS REQ'D 5/8" GYP. BD FINISH BATT INSULATION PER ENERGY CALCULATIONS 3" = 1'-0" HEADER AND SILL (EXT. PLASTER) VINYL WINDOW WOOD CASING, SELECT PER OWNER VINYL WINDOW JAMB (EXT. PLASTER) 3" = 1'-0" 'MILGARD' TUSCANY SERIES VINYL WINDOW FRAME. (1″ SETBACK, STUCCO KEY). BATT INSULATION PER ENERGY CALCULATIONS 5/8" GYP. BD FINISH WD. SHIM OR FILLER AS REQ'D LINE OF SILL BELOW VINYL SLIDING PATIO DOOR JAMB (EXT. PLASTER) 3" = 1'-0" 'MILGARD' TUSCANY SERIES VINYL PATIO SLDING DOOR FRAME. (1" SETBACK) MESH SCREEN BATT INSULATION PER ENERGY CALCULATIONS 5/8" GYP. BD FINISH WD. SHIM OR FILLER AS REQ'D WD. CASING, SELECT PER OWNER WD. CASING, SELECT PER OWNER 'MILGARD' TUSCANY SERIES VINYL PATIO SLDING DOOR FRAME. (1" SETBACK) VINYL SLIDING PATIO DOOR HEADER AND SILL (EXT. PLASTER) 3" = 1'-0" 2" PE R PL A N INTERIOR FLOOR FINISH O/ GYPCRETE O/ PLYWD. PER STRUCT.MESH SCREEN VINYL WINDOW JAMB (HOR. SIDING OR BOARD AND BATTEN) 3" = 1'-0" 'MILGARD' TUSCANY SERIES VINYL WINDOW FRAME. MESH SCREEN BATT INSULATION PER ENERGY CALCULATIONS 5/8" GYP. BD FINISH WD. SHIM OR FILLER AS REQ'D WD. CASING, SELECT PER OWNER LINE OF SILL BELOW HARDIEPLANK LAP SIDING O/ FELT UNDERLAYMENT O/ PLYWD SHEATHING PER STRUCT. 2X FRAMING PER STRUCT. LINE OF JAMB 3" = 1'-0" HEADER AND SILL (HOR. SIDING) VINYL WINDOW WD. CASING, SELECT PER OWNER WD. CASING, SELECT PER OWNER SEALANT AND BACKER ROD WD. CASING, SELECT PER OWNER 'MILGARD' TUSCANY SERIES VINYL PATIO SLDING DOOR FRAME. MESH SCREEN BATT INSULATION PER ENERGY CALCULATIONS 5/8" GYP. BD FINISH WD. SHIM OR FILLER AS REQ'D WD. CASING, SELECT PER OWNER HARDIEPLANK SIDING OR HARDIEPANEL BOARD AND BATTEN VERTICAL SIDING O/ FELT UNDERLAYMENT O/ PLYWD SHEATHING PER STRUCT. HARDIETRIM WINDOW TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH. SEALANT AND BACKER ROD HEADER PER STRUCT. WD. SHIM OR FILLER AS REQ'D 5/8" GYP. BD FINISH BATT INSULATION PER ENERGY CALCULATIONS WD. CASING, SELECT PER OWNER'MILGARD' TUSCANY SERIES VINYL PATIO SLDING DOOR FRAME. LINE OF JAMB 2" PE R PL A N DEX-O-TEX ELASTOMERIC FINISH INTERIOR FLOOR FINISH O/ GYPCRETE O/ PLYWD. PER STRUCT.MESH SCREEN VINYL SLIDING PATIO DOOR HEADER AND SILL (HOR. SIDING) 3" = 1'-0" BACKER ROD AND SEALANT HARDIETRIM WINDOW TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH HARDIEPANEL BOARD AND BATTEN SIDING O/ FELT UNDERLAYMENT O/ PLYWD SHEATHING PER STRUCT. MESH SCREEN LINE OF JAMB 3" = 1'-0" HEADER AND SILL (BOARD AND BATTEN) VINYL WINDOW 'MILGARD' TUSCANY SERIES VINYL WINDOW FRAME GALVANIZED Z FLASHING, PAINTED (MATCH TRIM) HARDIEPANEL BOARD AND BATTEN SIDING O/ FELT UNDERLAYMENT O/ PLYWD SHEATHING PER STRUCT. HARDIETRIM WINDOW TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH BACKER ROD AND SEALANT HARDIETRIM WINDOW TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH BACKER ROD AND SEALANT MESH SCREEN 'MILGARD' TUSCANY SERIES VINYL WINDOW FRAME VINYL SLIDING PATIO DOOR JAMB (HOR. SIDING OR BOARD AND BATTEN) 3" = 1'-0" HARDIEPLANK LAP SIDING O/ FELT UNDERLAYMENT O/ PLYWD SHEATHING PER STRUCT. GALVANIZED Z FLASHING, PAINTED (MATCH TRIM) HARDIETRIM WINDOW TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH 'MILGARD' TUSCANY SERIES VINYL PATIO SLDING DOOR FRAME. LINE OF JAMB 2" PE R PL A N INTERIOR FLOOR FINISH O/ GYPCRETE O/ PLYWD. PER STRUCT.MESH SCREEN VINYL SLIDING PATIO DOOR HEADER AND SILL (BOARD AND BATTEN) 3" = 1'-0" DEX-O-TEX ELASTOMERIC FINISH DEX-O-TEX ELASTOMERIC FINISH 6" M I N . LA P EXT. PLASTER GALVANIZED 'Z' FLASHING DRIP EDGE (DO NOT CAULK) LAP AND CONTINUE WEATHER-RESISTANT BARRIER O/ SELF ADHESIVE SELF ADHESIVE TAPE "J" MTL. CHANNEL SEALANT 'MILGARD' TUSCANY SERIES VINYL WINDOW FRAME (1″ SETBACK, STUCCO KEY). WOOD CASING, SELECT PER OWNER SELF ADHESIVE TAPE (WRAP ENTIRE OPENING) SELF ADHESIVE TAPE (WRAP ENTIRE OPEN'G) HEADER PER STRUCT. 7/8" EXT. PLASTER O/ MTL. LATH AND FELT UNDERLAYMENT O/PLYWD SHEATHING PER STRUCT. WD. SHIM OR FILLER AS REQ'D 5/8" GYP. BD FINISH BATT INSULATION PER ENERGY CALCULATIONS 6" M I N . LA P EXT. PLASTER GALVANIZED 'Z' FLASHING DRIP EDGE (DO NOT CAULK) LAP AND CONTINUE WEATHER-RESISTANT BARRIER O/ SELF ADHESIVE SELF ADHESIVE TAPE SELF ADHESIVE TAPE (WRAP ENTIRE OPEN'G) LINE OF JAMB (BEYOND) SELF ADHESIVE TAPE (WRAP ENTIRE OPEN'G and ON TO DECK'G) SELF ADHESIVE TAPE (WRAP ENTIRE OPEN'G) CAULK ALL AROUND WINDOW FRAME PRIOR TO WINDOW PLACEMENT - TYP. CAULK ALL AROUND WINDOW FRAME PRIOR TO WINDOW PLACEMENT - TYP. CAULK ALL AROUND WINDOW FRAME PRIOR TO WINDOW PLACEMENT - TYP. SELF ADHESIVE TAPE (WRAP ENTIRE OPEN'G and ON TO DECK'G) CAULK ALL AROUND WINDOW FRAME PRIOR TO WINDOW PLACEMENT - TYP. HEADER PER STRUCT. WD. SHIM OR FILLER AS REQ'D 5/8" GYP. BD FINISH BATT INSULATION PER ENERGY CALCULATIONS HARDIEPLANK LAP SIDING O/ FELT UNDERLAYMENT O/ PLYWD SHEATHING PER STRUCT. GALVANIZED Z FLASHING, PAINTED (MATCH TRIM) HARDIETRIM WINDOW TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH CAULK ALL AROUND WINDOW FRAME PRIOR TO WINDOW PLACEMENT - TYP. WD. CASING, SELECT PER OWNER HEADER PER STRUCT. WD. SHIM OR FILLER AS REQ'D 5/8" GYP. BD FINISH BATT INSULATION PER ENERGY CALCULATIONS CAULK ALL AROUND WINDOW FRAME PRIOR TO WINDOW PLACEMENT - TYP. 2X FRAMING PER STRUCT. SELF ADHESIVE TAPE (WRAP ENTIRE OPENING) CAULK ALL AROUND WINDOW FRAME PRIOR TO WINDOW PLACEMENT - TYP. BACKER ROD AND SEALANT WD. CASING, SELECT PER OWNER 2X FRAMING PER STRUCT. 2X FRAMING PER STRUCT. CAULK ALL AROUND WINDOW FRAME PRIOR TO WINDOW PLACEMENT - TYP. SELF ADHESIVE TAPE (WRAP ENTIRE OPEN'G and ON TO DECK'G) GALVANIZED Z FLASHING, PAINTED (MATCH TRIM) HARDIEPANEL BOARD AND BATTEN SIDING O/ FELT UNDERLAYMENT O/ PLYWD SHEATHING PER STRUCT. HARDIETRIM WINDOW TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH WD. CASING, SELECT PER OWNER HEADER PER STRUCT. WD. SHIM OR FILLER AS REQ'D 5/8" GYP. BD FINISH BATT INSULATION PER ENERGY CALCULATIONS CAULK ALL AROUND WINDOW FRAME PRIOR TO WINDOW PLACEMENT - TYP. CAULK ALL AROUND WINDOW FRAME PRIOR TO WINDOW PLACEMENT - TYP. MESH SCREEN "J" MTL. CHANNEL SELF ADHESIVE TAPE (WRAP ENTIRE OPEN'G) CAULK ALL AROUND WINDOW FRAME PRIOR TO WINDOW PLACEMENT - TYP. HARDIEPLANK SIDING OR HARDIEPANEL BOARD AND BATTEN VERTICAL SIDING O/ FELT UNDERLAYMENT O/ PLYWD SHEATHING PER STRUCT. HARDIETRIM WINDOW TRIM, 3.5" WIDTH, 4/4 SMOOTH FINISH. CAULK ALL AROUND WINDOW FRAME PRIOR TO WINDOW PLACEMENT - TYP. CEILING FINISHES, SEE SECTIONS AND CEILING PLAN CEILING FINISHES, SEE SECTIONS AND CEILING PLAN CEILING FINISHES, SEE SECTIONS AND CEILING PLAN FRAMING, SEE STRUCTURAL FRAMING, SEE STRUCTURAL FRAMING, SEE STRUCTURAL Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 6 7 8 5 DETAILS AD3 101418 20 16 12 6 3/4" MIN., TYP. ROUGH OPENING 4 1/2" MIN. 6 3 / 4 " M I N . , TY P . 6 3 / 4 " M I N . , TY P . 6 3/4" MIN., TYP. 4 1 / 2 " MI N . 4 1 / 2 " MI N . 3/4" MIN. 4. TOP (HEAD) STRIP 1. BOTTOM STRIP 3 SIDE STRIP FOLD BACK DAM AT CORNER - DO NOT CUT! WINDOW ROUGH OPENING PER PLAN RO U G H O P E N I N G 3/4" MIN. 3. SIDE (JAMB) STRIP 2. SILL PAN FLASHING FLEXIBLE FLASHING SHALL BE MINIMUM THICKNESS OF 40-MIL SELF-ADHERING ELASTOMERIC WATERPROOFING MEMBRANE AND INSTALLED IN A WEATHERBOARD FASHION AROUND THE FULL PERIMETER OF THE OPENING AS SHOWN BELOW OR AS PER MANUFACTURER'S SPECIFICATIONS BY QUALIFIED INSTALLERS. RIGID PAN FLASHING SHALL BE 24GA. GALVANIZED OR NON-CORROSIVE METAL OF ONE-PIECE CONSTRUCTION, IF PAN FLASHINGS ARE OF MULTIPLE-PIECE CONSTRUCTION THEN JOINTS SHALL BE SOLDERED OR SECTIONS SHALL BE LAPPED A MINIMUM OF 4" WITH WATERPROOFING SEALANT (MINIMUM 2 CONTINUOUS BEADS) APPLIED BETWEEN LAPPED SECTIONS PARALLEL TO DRAINAGE DIRECTION. WATERPROOFING SEALANTS REFERRED TO HEREIN SHALL BE OF THE TYPE APPROVED FOR SPECIFIC APPLICATIONS AND USE AS INTENDED AND SPECIFIED BY WINDOW MANUFACTURER OR BY WATERPROOFING PRODUCTS' MANUFACTURER AND SHALL BE APPLIED BY QUALIFIED INSTALLERS. FLEXIBLE AND RIGID SILL PAN FLASHING INSTALLATION 1. ATTACH BTTM. (SILL) STRIP WITH TOP EDGE LEVEL W/ ROUGH SILL - EXTEND BEYOND EDGE OF ROUGH OPNG' AT LEAST 9" PLUS 1" EXTENSION BEYOND JAMB STRIPS ON BOTH SIDES. 2. INSTALL FLEXIBLE SILL PAN FLASHING, FOLLOWED BY RIGID PAN FLASHING - LAP BOTTOM FLANGE OVER BOTTOM (SILL) STRIP (SEE ABOVE FOR ADDITIONAL INFORMATION). 3. ATTACH SIDE (JAMB) STRIPS WITH INNER FLAP EDGE EVEN WITH THE INTERIOR EDGE OF ROUGH JAMB FRAMING. START STRIP 1" BELOW LOWER EDGE OF THE BOTTOM (SILL) STRIP AND EXTEND 6" ABOVE LOWER EDGE OF LINTEL. LAP INNER FLAP OF SIDE (JAMB) STRIPS OVER SIDE FLANGE OF SILL PAN FLASHING. 4. AT CURTAIN WALL WINDOW LOCATIONS - ATTACH TOP (HEAD) FLEXIBLE FLASHING WITH SIDE EDGES EXTENDING A MIN. 6" PAST JAMB ROUGH OPENING AND TOP EDGE EXTENDING A MIN. 6" ABOVE THE HEAD ROUGH OPENING. CUT FLASHING VERTICALLY ALONG JAMB EDGE TO BOTTOM OF HEAD AND FOLD BOTTOM FLAP UNDERNEATH HEAD. 5. ATTACH TOP (HEAD) STRIP WITH BOTTOM EDGE ALIGNED WITH HEAD ROUGH OPENING, LAP ENDS OVER SIDE STRIP EXTENDING MIN. 1" PAST EDGE OF SIDE STRIP. 6" M I N 5 TOP STRIP 4 FLEXIBLE HEAD FLASHING (AT CURTAIN WALLS ONLY) HEAD FLASHING 6" M I N 6" MIN 4"MIN 4"MIN MI N 4"1/ 2 " SOLDER BACK DAM AT SEAM - ENSUREWATER-TIGHT SEAL 2C RIGID SILL PAN FLASHING MIN MIN 6" MI N 6" 6" 2B SELF-ADHERING MEMBRANE CLOSURE SADDLE (OPTIONAL) 2 FLEXIBLE SILL PAN FLASHING 1 BOTTOM STRIP 2A SELF-ADHERING MEMBRANE 3" DIA. CIRCLE PATCH FLASHING INSTALLATION 1 1/2" = 1'-0" 1/ 2 " NOTE: AVOID USING MECHANICAL FASTENERS THROUGH RIGID PAN FLASHINGS WHERE POSSIBLE. IF MECHANICAL FASTENERS MUST BE USED THROUGH RIGID PAN FLASHINGS, (1) FASTENERS MUST BE GALVANIZED OR NON-CORROSIVE, AND (2) PENETRATIONS AND FASTENER HEADS MUST BE THOROUGHLY SEALED WITH APPROVED WATERPROOFING SEALANT. ANY MECHANICAL FASTENERS AT JAMBS MUST NOT BE INSTALLED WITHIN 1" OF TOP OF SILL OR TOP OF FLOOR. 6" MIN 4"MI N 1/ 2 " SOLDER BACK DAM AT SEAM - ENSURE WATER-TIGHT SEAL 6"MI N 3 - 1 / 2 " O R 5 - 1 / 2 " ( F . V . ) 4"MIN 4" MIN MIN. 24GA NON-CORROSIVE METAL SILL PAN WITH CONTINUOUSLY SOLDERED JOINTS NO MECHANICAL PENETRATIONS WITHIN BOTTOM 1/2" OF SILL PAN. APPLY SEALANT OVER HEADS OF ALL MECHANICAL FASTENERS THROUGH FLASHING DOOR OPENING BEND BACK DAM 45° TOWARD EXTERIOR - SOLDER BACKDAM TO SIDE FLANGE INSTALL SHIMS AS NECESSARY TO PROVIDE SLOPE TOWARD EXTERIOR - DO NOT PENETRATE THROUGH TOP OF SILL PAN WITH MECHANICAL FASTENERS IF USING MULTI-PIECE SILL PAN FLASHING, LAP ENDS MIN. 4" AND SET INTO CONTINUOUS BEAD OF SEALANT; APPLY CONT. BEAD OF SEALANT AT EXPOSED END JOINT APPLY CONTINUOUS SEALANT BEHIND BOTTOM EDGE OF SILL PAN APRON LAP BOTTOM FLANGE OF SILL PAN APRON OVER VERTICAL FLANGE OF "L" FLASHING MIN. 24 GA NON-CORROSIVE METAL "L" FLASHING - LAP ENDS MIN. 4" AND SET INTO CONTINUOUS BEAD OF SEALANT; APPLY CONT. BEAD OF SEALANT AT EXPOSED END JOINT EXT. DOOR THRESHOLD PAN FLASHING 1 1/2" = 1'-0" ANOD. ALUM. DRIP AND VINYL SWEEP and ASTRAGAL WEATHERSTRIP INSERT ALUM. THRESHOLD DOOR SEE DOOR SCHEDULE EXTERIOR DOOR THRESHOLD N.T.S. NOTE: COORDINATE DOOR FLASHING w/ DETAIL 18/AD4 1.) NOTES: 2 LEVEL CHANGES 1/ 2 " M A X . IF D O O R S W I N G S OV E R T H E L A N D I N G DOOR LANDING SIDE A LANDING, WITH A WIDTH NOT LESS THAN THE WIDTH OF DOOR & LENGTH IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 36", WILL BE PROVIDED ON EA. SIDE OF DOORS. THE ELEVATION OF LANDING SHALL NOT EXCEED 1/2" DIFFERENCE THAN THE THRESHOLD OF THE DOORWAY IF DOOR SWINGS OVER THE LANDING OR STEPS. ALSO, THE MAXIMUM SLOPE OF ANY LANDING SHALL NOT EXCEED 1/4" PER FOOT. 1 7. 7 5 " M A X . I F D O O R DO E S N O T S W I N G OV E R T H E L A N D I N G LEVEL CHANGES A LANDING, WITH A WIDTH NOT LESS THAN THE WIDTH OF DOOR & LENGTH IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 36", WILL BE PROVIDED ON EA. SIDE OF DOORS. THE ELEVATION OF LANDING SHALL NOT EXCEED 7.75" DIFFERENCE THAN THE THRESHOLD OF THE DOORWAY IF DOOR DOES NOT SWING OVER THE LANDING OR STEPS. ALSO, THE MAXIMUM SLOPE OF ANY LANDING SHALL NOT EXCEED 1/4" PER FOOT. 2.) DOOR LANDING SIDE THRESHOLD SIDE THRESHOLD SIDE MAX. SLOPE 1/4" PER FOOT MAX. SLOPE 1/4" PER FOOT THRESHOLD AND LEVEL CHANGES AT DOOR LANDING N.T.S. BOTH SIDES OVER SLIDING DOORS, 5/8" TYPE 'X' GYP. BD. DOOR DIMENSION 1/ 2 " 2 - 2 X WOOD STUD SEE SCHEDULE1 X WD JAMB INSIDE WARDROBE SLIDING WARDROBE DOOR JAMB 3" = 1'-0" GYP.BRD. "J' MOLDING SEE SCHEDULE 5/8" THK. TYPE 'X' 2 x WOOD STUDS GYPSUM BD. DO O R D I M E N S I O N SLIDING DOOR, 1/2" BOTH SIDES SELECT PER OWNER FLOOR FINISH 1/4" SHIM 1X WD HEADER SLIDING WARDROBE DOOR HEAD & SILL 3" = 1'-0" GYP.BRD. "J' MOLDING, TYP. GARAGE DOOR TRACK PER MANUFACTURER STEEL BEAM PER STRUCT. CORNER BEAD GARAGE HEADER 3" = 1'-0" WOOD BEAM PER STRUCT. 7/8" EXT. PLASTER O/ MTL. LATH AND BUILDING UNDERLAYMENT WOOD FRAMING 1" X 5 1/4" W HARDIETRIM BOARD PROVIDE WOOD SHIM AS NEEDED GYP.BRD. "J' MOLDING STUCCO "J" SCREED GARAGE JAMB 3" = 1'-0" GARAGE DOOR SEE DOOR SCHEDULE GOLD-ZINC 11 BALL BEARING QUIET ROLLERS GALVANIZED L-ANGLE GALVANIZED C-CHANNEL 14 GAUGE SAFEGUARD HINGE WITH 12 GAUGE ROLLER BRACKET PROVIDE WEATHERSEAL BOTH SIDE AND BOTTOM OF DOOR 2X DOUBLE PLATE W/ 5/8" LAG BOLT (COUNTERSINK) PROVIDE WOOD SHIM AS NEEDED 1" X 5 1/4" W/ VERT. HARDIETRIM BOARD 7/8" CEMENT PLASTER O/ METAL LATH O/ WATERPROOFING PAPER and CORNER BEAD NOTE: GARAGE DOOR SHALL BE INSTALLED PER MANUFACTURES RECOMENDATION INTERIOR DOOR HEAD (JAMB SIM.) 3" = 1'-0" HEADER OR DOUBLE STUDS AT JAMB 5/8" GYP. BD. BOTH SIDES. SHIM 1X FINISH WOOD FRAME 1/2"X1 1/2" DOOR STOP DOOR SEE DOOR SCHEDULE WOOD TRIM SELECT PER OWNER 7/8" CEMENT PLASTER O/ METAL LATH O/ WATERPROOFING PAPER O/ SELF-ADHESIVE MEMBRANE PRESSURE TREATED 2X P.T. SILL PLATE EXT. PLASTER GALVANIZED 'Z' FLASHING DRIP EDG (DO NOT CAULK) EXT. PLYWOOD SHEATHING WHERE OCCURS PER STRUCT. 4" LINE OF ROUGH GRADE 6" M I N . TO C O N C FL O O R 2" 8" M I N . TO R O U G H G R A D E SEALANT W/ COMPRESSIBLE FILLER LINE OF CONC. SLAB 8" M I N . 3" METAL DOWNSPOUT, PAINTED TO MATCH WALL PRE-FAB SPLASH BLOCK AS REQ'D AT PLANTER ONLY FINISH GRADE G.I. STRAP DOWNSPOUT TO WALL AT 8'-0" O.C (PRE-DRILL HOLE FOR ATTACHMENT SCREW, CAULK HOLE PRIOR TO SCREW PLACEMENT) ROOF DRAIN EXTERIOR 3" = 1'-0" WEEP SCREED DETAIL 3" = 1'-0" APPLY COLOR COAT TO MATCH ADJACENT EXT. PLASTER COLOR O/ HIGH DENSITY FOAM FILLER 7/8" CEMENT PLASTER O/ METAL LATH O/ WATERPROOFING PAPER O/ EXT.SELF-ADHESIVE MEMBRANE O/ PLASTER GALVANIZED 'Z' FLASHING DRIP EDG (DO NOT CAULK), SEE DETAIL 9/AD4 for MORE INFO. NOTE: SELF-ADHESIVE MEMBRANE FROM PLY.WD. TO FOUNDATION NOTE: SELF-ADHESIVE MEMBRANE FROM PLY.WD. TO FOUNDATION 6" 6" 24" MIN. CONCRETE CURBWITH #4 CONT. 1/2" EXPANSIONJOINT MATERIAL CONCRETE PAD5" THICK CONT. FOOTINGWITH #5 AT 16" O.C.VERTICAL AND 2-#5CONT. EA. SIDE 6" SPLIT FACED CMU W/ 1-#5 CONT. @ TOP& BOTTOM & 24" 0.C.MAX. AND # 5 AT 16" O.C. VERTICAL 3" C L R . 12 " M I N . 6" SEE STRUCTURALCONCRETE SLAB INTERIOR EXTERIOR SIDEWALK 02 8 3 0 - 0 6 TRASH ENCLOSURE SECTION 3/4" = 1'-0" 7/8" CEMENT PLASTER O/ MTL. LATH w/ BASE SCREED SMOOTH FACE AT INTERIOR,PAINTED WITH 2 COATS OFEPOXY PAINT, SEE DETAIL6/AD1 SIM. FOR T.O.WALL 4x4 POST REDWOOD WOOD GATE (3) METAL. HINGE 1x4 REDWOOD CEMENT PLASTER O/ CMU BLOCK WALL PER ELEVATION ELEVATION 3" = 1'-0" PLAN SECTION 2x6 REDWOOD CAP W/ PAINT 1x4 REDWOOD AT B/S TOP & BOTTOM 1x4 REDWOOD MTL. POST BASE 1" WOOD FENCE AND GATE DETAIL AND JAMB 1 1/2" = 1'-0" 3 1/2" TYP. 1x8 REDWOOD BDS. OVERLAPPED 4x4 REDWOOD POST WOOD GATE 2x4 REDWOOD GATE JAMB 2x4 REDWOOD GATE JAMB 7 1/4" TYP. 3 1/2" TYP. HE I G H T P E R E L E V A T I O N D W G S 5' - 0 " M A x NOTE: SEE ELEVATIONS for LOCATIONS (3) HEAVY DUTY STAINLESS HINGE W/ RETURN SPRING HINGE CLOSURE 1/2" LAG-BOLT w/ LEADED COUNTERSINKED SLEEVE SECTION 1x8 REDWOOD VERT.BOARDS OVERLAPED Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 6 4 5 DETAILS AD4 18 14 1 2 13 10 7 9 11 NOT USED NOT USED 20 1 1'-0" 3/4" MDF. SHELF PRIMED AND PAINTED SEMI-GLOSS TO MATCH INT. WALL 3/4" MDF. BRACKET STIFFENER @ 36"O.C. PRIMED AND PAINTED SEMI-GLOSS TO MATCH INT. WALL PREDRILLED FOR POLE TO F I N I S H F L O O R 5' - 0 " 3" 3" 1 1/2" DIA. WOOD POLE PAINTED. SHELF & POLE 1 1/2" = 1'-0" 3" #12 SCREW @ 16" O.C. TYP. at BLOCKING 3/4" MDF. CONT. REAR AND SIDE LEDGERS, SCREW THRU. GYPSUM WALL BOARD TO STUDS AND BLOCKING, ATTACH BOTT. w/ 3" #12 SCREW @ EA. STUD SEE PLAN FOR WALL TYPE AND CONSTRUCTION. PROVIDE FIRE AND DRAFT STOPS AS REQ'D. PER BLDG. CODE 5/8" GYPBD. SHT'G. TYPE 'X' ON EACH SIDE OF CAB'T. AT 1-HR. FIRE-RATED WALL ALL UNUSED KNOCKOUTS OR OTHER HOLES SHALL BE PROPERLY SEALED UNFACED FIBERGLASS OR MINERAL WOOL BATT AS REQ'D. RECESSED CABINETS SHALL BE GALVANIZED METAL CONSTRUCTION MIN. 24GA THICKNESS ALL CONDUIT PENETRATIONS INTO ELECTRICAL CABINET SHALL BE FILLED AT WALL W/ DRYWALL COMPOUND, TAPE AND SANDED TO FORM A COMPLETE SEAL ALL AROUND; WHERE APPLICABLE INSTALL FACEPLATE COVER AT CABINET OPENINGS RECESSED ELEC. OR FIXTURE CABINET 1 1/2" = 1'-0" PLYWOOD SUB-FLOOR. TUB ENCLOSURE INSULATION BUTT PER WALL SCHEDULE.2X WOOD STUD W/ SOUND PRE-FAB. FIBERGLASS FLEXIBLE SEALANT INTO 1/8" MIN. GAP. 2X BLOCKING BATH TUB FRAMING / FINISHES 1 1/2" = 1'-0" CEMENT BACKERBOARD ORONE LAYER TYPE 'X' WATER RESISTANTGYP BD AT 1HR RATED WALL WHEREOCCURS. WALL FINISHES PER TENANT 1" THK. TYPE 'X' 2 LAYERS OF 5/8"TYPE 'X' GYP. BD. CHASE GYP. BD. PROVIDE BATT INSULATION AGAINST UNIT SPACE 20 GA. CAP FLASHING W/ HEMMED EDGE 1X PLASTER STOP 5/8" PLYWD METAL-LOUVER VENT SIZE PER MECH-PLAN PROVIDE CORROSION RESISTENT METAL INSECT SCREEN SLOPE 1/2" PER FOOT 2-HOUR RATED EXHAUST SHAFT- SECTION 1 1/2" = 1'-0" EXT. PLASTER GALVANIZED 'Z' FLASHING DRIP EDGE (DO NOT CAULK) O/ WEATHER-RESISTANT BARRIER (WRAP FRAMING w/ SELF ADHESIVE) 7/8" EXT. PLASTER O/ MTL. LATH AND FELT UNDERLAYMENT O/ SHEATHING CAULK ALL AROUND CHASE 5/8" TYPE 'X' G.W.B. O/ 2X CEILING JOIST PLYWD. SUBFLOOR PER STRUCT. PROVIDE BATT INSULATION LIVING SPACE. 7/8" EXT. PLASTER O/ PAPER-BACKED MTL. LATH 2 LAYERS OF 5/8" TYPE 'X' GYP. BD. ALL SIDES 1" THK. TYPE 'X' GYP. BD. ALL SIDES FLOOR FINISHES PER SCHEDULE 2-HOUR RATED EXHAUST SHAFT - SECTION 1 1/2" = 1'-0" COVE LIGHTING AT SOFFIT 1 1/2" = 1'-0" CE I L I N G H E I G H T PE R R E F L E C T E D C E I L I N G P L A N PE R RC P 2X WD. NAILER PROVIDE TAPE LED LIGHT, CONTINUOUS. PER RCP 5/8" GYP. BD FINISH 1'-0" 2X BRACE AT COVE FRAMING FLOOR or CEILING JOIST PE R R E F L E C T E D CE I L I N G P L A N 2X4 BLKG. CORNER BEAD 5/8" GYP. BD. O/ 2X4 FRAMED SOFFIT INTERIOR SOFFIT 3" = 1'-0" FLOOR or CEILING JOIST 2X WD STUDS @ 16" O.C. PER STRUCTURE PLAN 5/8" GYP. BD. BOTH SIDE TYPICAL ONE LAYER OF 5/8" TYPE 'X' GYP. BD. @ UNDERSIDE OF STAIR STRINGERS, STAIR-BEARING WALL, AND GARAGE TO ACHIEVE 1-HR. CONSTRUCTION. THE 5/8" TYPE 'X' GYP. BD. SHALL BE EXTENDED FROM TOP OF FLOORING ALL THE WAY TO THE BOTTOM OF STAIR STRINGERS, FLOOR, AND/OR, CEILING JOISTS. INTERIOR WALL 3" = 1'-0" PLAN 5/8" TYPE 'X' GYP. BD. BOTH SIDE PROVIDE INSULATION AT PLUMBING UL APPROVED FIRE RATED RECEPTACLES BOX (ATTACHED TO STUD) R13 BATT INSULATION 2X WD. STUDS @ 16" O.C. ELEC. & PLUMBING AT WALL 3" = 1'-0" PLAN 2'-0" MIN. 3/ 4 " 1 1 / 2 " 1 1 / 2 " 3'- 0 " M I N . PE R P L A N PE R P L A N STUD @ 16" O.C.SIDE O/ 2X4 WD.5/8" GYP. BD. EA. MOUNTS DRAWERSON 'ACURIDE' GLIDTYP. COUNTERTOP & BACKSPLASH SELECT PER OWNER.6" U. N . O . COUNTER & CABINET 1" = 1'-0" UPPER CABINET, SEE DETAIL 3/AD5 UNDER MOUNT LIGHTING PER PLAN CABINET CLOSURE TRIM WALL FRAMING COUNTER & CABINET MOUNTING N.T.S. NOTE: CASEWORK FASTENER SHALLCOMPLY w/ ASCE 7-16 13.4 3/4" X 1 1/2" CONT.SPACER ATTACHMENTCLEAT SECURED TOBACK OF UPPERCABINET and WALL PROVIDE CONT. BLOCKINGat TOP & BOTTOM forSECURED ATTACHMENT 3" #14 SCREW @ 16" O.C.TYP. at T&B FOR ALLCABINET MOUNTINGCONNECTORS 3/4" X 1 1/2" CONT.UPPER WEDGEDSHAPED CLEAT/LEDGERSECURED TO BACK OFUPPER CABINETSECURED TO WALL atBLOCKING LOCATIONS UPPER CABINET 2" #14 SCREW @ 16" O.C.TYP. at CLEAT/LEDGERLOCATED at BLOCKING Reviewed By: Drawn By: Date: Scale: Office Project Number: AS NOTED Plan Check: Revisions: Drawing Title: Project: Date Contractor: Consutant: THE DRAWINGS, IDEAS, ARRANGEMENTS AND SPECIFICATIONS CONTAINED IN THESE DOCUMENTS ARE THE PROPERTY AND COPYRIGHT OF SPACE LIGHT STRUCTURE DESIGN AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH SPACE LIGHT STRUCTURE DESIGN. WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF SPACE LIGHT STRUCTURE DESIGN. PRIOR TO THE COMMENCEMENT OF ANY WORK. 157 AND 159 GENOA STREET ARCADIA, CA 91007 Multi-Family Residential Project 4 UNITS GENOA JMP / TL 2017-25 VT 1 Information: URBAN DESIGN DESIGN ARCHITECTURE S INTERIORS Suite 2 South Pasadena, CA 91030 1414 Fair Oaks Avenue, Fax: Office:(626) 799-8818 (626) 799-8823 www.slsdinc.com S L 03-21-2023 2 Checker: Shawn Dalipe, 09-18-19 VCA File No: 32263-33226 1st Check, Plan Check No: 19-1509 10-15-19 Checker: Hirsch & Associates 1st Landscape Check, #1965 3 02-07-23 Code Update 6 3 4 5 DETAILS AD5 18 1 210 9 11 17 NOT USED NOT USED NOT USED NOT USEDNOT USED NOT USED NOT USED NOT USED NOT USED