Loading...
HomeMy WebLinkAbout157-159 Geona St A & B - 2022 - (2)18006 address: 20945 Delphine Drive PLANTING PLAN project name date: scale: dawing: job no: drawing content L-1 JK 1/8"=1'-0" 11/12/2019 walnut, california 91789 Group,Inc. email: jkda2002@gmail.com Sail Design tel: 626.383.7758 property owner revisions date checked: north arrow 4 Unit Condos Underground Service AlertUnderground Service AlertUnderground Service AlertUnderground Service Alert L CA L TWO WORKING DAYS BEFORE YOU DIG Call: TOLL FREE 1-8001-8001-8001-8001-8001-8001-8001-8001-800 227-2600227-2600227-2600227-2600227-2600227-2600227-2600227-2600227-2600 YORE G OU D I EBF All trees to be planted with commercial root barriers. 2" deep shredded Cedar bark to spread between plants. NOTE: All groundcover areas where plants are 4'oc or greater to have 2 layers of geotextile fabric in 2 different directions geotextile fabric installed 3" below finished grade w/ All non-lawn area with 3" shredded bark above 157-159 Genoa St, Arcadia CA 91006 COMMON NAME BOTANICAL NAME SYM. SIZE QTY. Remark TREE SHRUB / ACCENT COMMON NAME BOTANICAL NAME SYM. SIZE QTY. RemarkPF L L L L L L L H L L VICINITY MAP G / M ELEC G / M ELEC ELECG / MELECG / M ..\..\..\Dropbox\W\2018\18006-157Genoa\Capture.JPG Sheet 1of 3 18006 address: 20945 Delphine Drive IRRIGATION PLAN project name date: scale: dawing: job no: drawing content L-2 JK 1/8"=1'-0" 11/12/2019 walnut, california 91789 Group,Inc. email: jkda2002@gmail.com Sail Design tel: 626.383.7758 property owner revisions date checked: north arrow 4 Unit Condos Underground Service AlertUnderground Service AlertUnderground Service AlertUnderground Service Alert L CA L TWO WORKING DAYS BEFORE YOU DIG Call: TOLL FREE 1-8001-8001-8001-8001-8001-8001-8001-8001-800 227-2600227-2600227-2600227-2600227-2600227-2600227-2600227-2600227-2600 YORE G OU D I EBF 157-159 Genoa St, Arcadia CA 91006 G / M ELEC G / M ELEC ELECG / MELECG / M gpm size no. Area H.Zone 2 3/4" 1 240 sf L.Zone 8.4 3/4" 2 12 sf L.Zone 2 3/4" 3 200 H.Zone 4 3/4" 4 500 SF L.Zone 11.7 3/4" 5 60 SF L.Zone 14724Total Estimated applied Water Use in gallons per year: This is a constant water need value calculated for this hydrazine in this City. gal./yr. gal.. gal.. gal.. 7417 total Area to be landscape in square feet (S.f..): Sail Design Group, IncLANDSCAPE DESIGNER PROJECT SITE: REFERENCE # PROJECT gal..18048 18006 gal.. FOR SUMMER (JULY) 7307A W LF 1 5 1 = 0.4 = 10 = 2.9 = 1.00 = 5 = 4.68 = .58 = 30 = 75 = 55 = 20 75 80 X 626 256 6650 Cit y of Arcadia water service 18. 14. 15. 11. 10. 8. 6. 4. 3. 2. THIS DESIGN IS DIAGRAMMATIC. ALL PIPING, VALVES, ETC. SHOWN WITHIN ALL SPRINKLER HEADS ARE TO HAVE TRIPLE SWING JOINTS (EXCEPT WHERE NOTED ON PLANS). OF LARGER SIZES MAY BE APPROVED. ALL DAMAGED AND REJECTED PIPE SHALL BE REMOVED FROM THE SITE AT THE TIME OF THE SAID REJECTION. TWO (2) WORKING DAYS SHALL BE ALLOWED AFTER THE I.D.NUMBER IS OBTAINED AND BEFORE THE EXCAVATION WORK IS STARTED SO THAT UTILITY OWNERS CAN BE THE CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS AND VALVES IT IS THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO FAMILIARIZE THE IRRIGATION CONTRACTOR SHALL REPAIR OR REPLACE ALL ITEMS DAMAGED BY AND PAVING, ETC. READING AT THE IRRIGATION POINT OF CONNECTION TO THE ARCHITECT. DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS SHOWN ON THE DRAWINGS WHEN IT IS OBVIOUS IN THE FIELD THAT THERE ARE UNKNOWN OBSTRUCTIONS OR NOTIFICATION IS NOT GIVEN, THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY NECESSARY REVISIONS. THE INTENT OF THE CONTRACTOR IS TO PROVIDE 100% COVERAGE TO ALL HEADS, SPECIAL NOZZLES, OR PATTERNS TO ACHIEVE PROPER COVERAGE WITH A LOCATE VALVE CHART IN CONTROLLER - REDUCE AND ENCASE IN PLASTIC (AS BUILT). GUARANTEE: THE INSTALLED SPRINKLER SYSTEM SHALL BE GUARANTEED FOR CONTRACTOR WITHOUT EXPENSE TO THE OWNER. 19. 17. 16. 13. 12. 9. 7. 5. 1. IRRIGATION NOTES PAVED AREAS ARE FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS WHEREVER POSSIBLE. SET ALL VALVES AND QUICK COUPLERS NEXT TO WALKS OR PAVED SURFACES. PIPE SIZES SHALL CONFORM TO THOSE SHOWN ON THE DRAWINGS. NO SUBSTITUTIONS OF SMALLER PIPE SIZES SHALL BE PERMITTED, BUT SUBSTITUTIONS FINAL LOCATION OF THE AUTOMATIC CONTROLLER SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT AND OWNER. 120VAC ELECTRICAL POWER SOURCE AT CONTROLLER LOCATION SHALL BE PROVIDED BY OTHERS. BEFORE COMMENCING ANY EXCAVATION, THE CONTRACTOR SHALL OBTAIN AN UNDERGROUND SERVICE ALERT I.D. NUMBER BY CALLING 1-800-422-4133. NOTIFIED. ALL SPRINKLER HEADS SHALL BE SET PERPENDICULAR TO FINISH GRADE UNLESS OTHERWISE SPECIFIED. FOR OPTIMUM COVERAGE WITH MINIMAL OVER SPRAY ONTO WALKS, STREETS, ETC. HIMSELF WITH THE GRADE DIFFERENCES, LOCATION OF WALLS, AND UTILITIES. HIS WORK. HE SHALL COORDINATE HIS WORK WITH OTHER CONTRACTORS FOR THE LOCATION AND INSTALLATION OF PIPE SLEEVES AND LATERALS UNDER ROADWAYS THE SPRINKLER SYSTEM DESIGN IS BASED ON A MINIMUM OPERATING PRESSURE OF 60 P.S.I. AND A MAXIMUM FLOW DEMAND OF 75 G.P.M. THE CONTRACTOR SHALL VERIFY WATER PRESSURES PRIOR TO CONSTRUCTION. REPORT ANY DIFFERENCE BETWEEN WATER PRESSURE INDICATED ON THE DRAWINGS AND THE ACTUAL PRESSURE GRADE DIFFERENCES IN THE AREA. DIMENSIONS EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING. SUCH OBSTRUCTIONS OR DIFFERENCES SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. IN THE EVENT THAT THIS ALL SPRINKLER EQUIPMENT NOT OTHERWISE DETAILED OR SPECIFIED SHALL BE INSTALLED AS PER MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS. PLANTING AREAS. AS PART OF THE SCOPE OF WORK, PROVIDE ANY ADDITIONAL MINIMUM OF OVER SPRAY AT NO ADDITIONAL COST TO THE OWNER. INSTALLATION FOR THE CONTROL WIRES SHALL FOLLOW MAINLINE ROUTING. PROVIDE SLEEVES AS SHOWN ON DRAWING. USE SIZE DIAMETER MIN. SCH. 80 P.V.C. MIN. DEPTH TO TOP OF LINE. A PERIOD OF ONE (1) YEAR FROM THE DATE OF ACCEPTANCE OF THE WORK. SHOULD ANY TROUBLE DEVELOP WITHIN THE TIME SPECIFIED DUE TO INFERIOR OR FAULTY MATERIAL OR WORKMANSHIP, THE TROUBLE SHALL BE CORRECTED BY THE REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION REGARDING THIS SECTION OF WORK. 157-159 Genoa St, Arcadia Ca Cit y of Arcadia water service Sheet 2of 3 A 3/4" 3/4" 3/4"3/4" 24" 256 400 36" 576 900 SQUARE SPACING TRIANGULAR SPACING 12" 64 100 15" 100 156 18" 144 225 8" 28 44 6" 16 SQ.FT. 25 SQ.FT. S TO P.O.C. ADAPT AS REQUIRED 12"x12"x12" THRUST BLOCK (TYP.) TO SPRINKLERS PVC MALE ADAPTER BRASS NIPPLE (TYP.) BRASS UNION BRASS 90 ELL (TYP.) LENGTH, (TYP.) BRASS NIPPLE, 4" MIN. BACKFLOW PREVENTER 3/4" HOSE BIB W/30 MESH MODEL BRASS WYE STRAINER DETAIL SHEET JK NOT TO SCALE L-3 SHEET :3 Scale : Job No : DAWING : Date : OF 3 DRAWING CONTENT: REVISIONS:Date : Group,Inc Sail Design HIGH POINT VALVE (PLUMBED TOTechline AT EACH AIR/VACUUM RELIEF AR LF 2" TO 4" FROM EDGE Techline "END FEED" LAYOUTLINE FLUSHING VALVEPLUMBED TO PVC OR POLY PERIMETER LATERALS PVC OR POLY EXHAUST HEADER BERM) (CENTERED ON MOUND ORBLANK Techline TUBING AREA PERIMETER Techline TUBING LATERAL CONNECTION Techline START MALE ADAPTER PVC OR POLY SUPPLY HEADER REMOTE CONTROL FILTER AND PRVVALVE WITH DISC DETAIL - NO SCALE FLOW Detail 2.02 1" SCH 80 12" x 18" UNION PVC MAINLINE VALVE BOX 4" CLEAR 1 CU. FT. PEAGRAVEL SUMP(1- EA. CORNER)BRICK SUPPORT SECTION - NO SCALE LATERAL LINE PVC OR POLY VALVEREMOTE CONTROL FILTER 3/4" DISC TIONS. DENCE OF THE ACCEPTANCE OF THESE RESTRIC- TAILS SHALL CONSTITUTE PRIMA FACIA EVI- TION INC. VISUAL CONTACT WITH THESE DE- OWNERSHIP IS RETAINED BY NETAFIM IRRIGA- WHOLE OR PART IS FULLY AUTHORIZED. PUBLICATION AND REUSE BY ANY METHOD IN NOT LIMITED TO ANY PURPOSE. REPRODUCTION, BE RESTRICTED AND PUBLICATION THEREOF IS SIBILITY. THE USE OF THESE DETAILS SHALL NOT NECESSARY AND ARE THE SPECIFIERS' RESPON- MODIFICATIONS FOR SPECIFIC PURPOSES MAY BE FOR SUITABILITY IS NOT GIVEN OR IMPLIED. TO ANY SITE OR JOB CONDITION. WARRANTY APPLICABILITY TO PURPOSE OR COMPATIBILITY INC. IS NOT RESPONSIBLE FOR CORRECTNESS OR TIONS AND CONDITIONS, NETAFIM IRRIGATION ALLOWING FOR A WIDE VARIETY OF APPLICA- LIMITATIONS: SECTION - NO SCALE walnut, california 91789 email: jkda2002@gmail.com address: 20945 Delphine Drive fax: 1.888-880-9412 tel: 626.383.7758 NOTE: GUYING OF MULTI-BRANCHED TREES IS LEFT TO THE CONTRACTORS DISCRETION DEPENDING ON BRANCH STRUCTURE AND WIND EXPOSURE. 1/2" DIA. GREEN GARDEN HOSE SCH. 40 1/2" DIA. WHITE PVC PIPE GALVANIZED TURNBUCKLE 10 GA. GALVANIZED GUY WIRE 3 REQUIRED FINISH GRADE REDWOOD DEADMAN EACH GUY WIRE TO 24" BOX - 2x4x18 30" - 48" BOX - 2x4x30 * REFER TO TREE STAKING DETAILFOR PLANNING PIT SPECIFICATIONS4'-0" MIN. 18 " 18006 11-12-2019 1. ALL ELECTRIC WORK SHALL NOTES: (TYPICAL)GALV. PIPE CLAMPS 120V SERVICE GALV. CONDUITCONTROL WIRES IN 3"Ø IRRIGATION CONTROLLER 5' - 6 " SEE LEGEND ..\..\FLOW SENSOR.jpg CONFORM TO LOCAL CODES 6"Ø P.V.C. CL160 PIPE, LENGTHAS NECESSARY FOR ACCESS TOGATE VALVE PRESSURE MAINLINE P.V.C. MALE ADAPTER (2 REQ'D) GATE VALVE 1 CU. FT. MIN. OF PEA GRAVEL FINISH GRADE ROUND, PLASTIC VALVE BOX ASPER SPECS. BRANDED "G.V." ONLID. SET FLUSH W/ FINISH GRADEIN TURF AREA, SET 2" ABOVE FINISH GRADE IN GROUND COVERAREA. FINISH GRADE VALVE BOXSEE SPECS. BRICK SUPPORTS(THREE) 3/4" GRAVEL SUMP (1 CUBIC FOOT) Detail 7.01 SECTION - NO SCALE SEESPECS Techline 17mm TUBING LINE FLUSHINGVALVE F-TLFV-1 (PROVIDED)COMPRESSION RING TIONS. DENCE OF THE ACCEPTANCE OF THESE RESTRIC- TAILS SHALL CONSTITUTE PRIMA FACIA EVI- TION INC. VISUAL CONTACT WITH THESE DE- OWNERSHIP IS RETAINED BY NETAFIM IRRIGA- WHOLE OR PART IS FULLY AUTHORIZED. PUBLICATION AND REUSE BY ANY METHOD IN NOT LIMITED TO ANY PURPOSE. REPRODUCTION, BE RESTRICTED AND PUBLICATION THEREOF IS SIBILITY. THE USE OF THESE DETAILS SHALL NOT NECESSARY AND ARE THE SPECIFIERS' RESPON- MODIFICATIONS FOR SPECIFIC PURPOSES MAY BE FOR SUITABILITY IS NOT GIVEN OR IMPLIED. TO ANY SITE OR JOB CONDITION. WARRANTY APPLICABILITY TO PURPOSE OR COMPATIBILITY INC. IS NOT RESPONSIBLE FOR CORRECTNESS OR TIONS AND CONDITIONS, NETAFIM IRRIGATION ALLOWING FOR A WIDE VARIETY OF APPLICA- LIMITATIONS: 1" IRRIGATION WATER LINE SUB-METER FOR IRRIGATION USE ONLY. GATE VALVE. BACKFLOW DEVICE EXISTING WATER MAIN LINE. DOMESTIC WATER LINE. MAIN WATER METER. 4 Unit Condos 157-159 Genoa St, Arcadia CA 91006 TREES PLANTED 1” below the surrounding finish grade w/ unamended native soil beneath the root ball TREES PLANTED 1” below the surrounding finish grade w/ unamended native soil beneath the root ball 1"BELOW GRADE TREES PLANTED 1” below the surrounding finish grade w/ unamended native soil beneath the root ball