HomeMy WebLinkAbout400 S Baldwin Ave - 2023 - Juny's Baked1
AC
ITEM
MECHANICAL EQUIPMENT SCHEDULE
REVISIONS
J
S
E
N
G
I
N
E
E
R
I
N
G
,
I
N
C
.
STAMP
M1
WE
S
T
F
I
E
L
D
M
A
L
L
40
0
S
.
B
A
L
D
W
I
N
A
V
E
.
S
U
I
T
E
B
3
A
&
S
B
4
,
AR
C
A
D
I
A
,
C
A
.
9
1
0
0
7
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
-
J
U
N
Y
'
S
B
A
K
E
D
CEILING PLAN
1/4"=1'-0"
FLOOR PLAN
1/4"=1'-0"
(E)
(E)
(E)
(E)
(E)
CEILING PLAN
1/4"=1'-0"
FLOOR PLAN
1/4"=1'-0"
REVISIONS
J
S
E
N
G
I
N
E
E
R
I
N
G
,
I
N
C
.
STAMP
M2
WE
S
T
F
I
E
L
D
M
A
L
L
40
0
S
.
B
A
L
D
W
I
N
A
V
E
.
S
U
I
T
E
B
3
A
&
S
B
4
,
AR
C
A
D
I
A
,
C
A
.
9
1
0
0
7
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
-
J
U
N
Y
'
S
B
A
K
E
D
DOMESTIC WATER PIPING SIZING
FIXTURE CONNECTION SCHEDULE (BRANCH SIZES)
PIPE MATERIALS
SERVICES LOCATION MATERIAL JOINING
METHOD REMARKS
DOMESTIC
COLD & HOT
WATER
UNDERGROUND RIGID COPPER( TYPE K)BRAZED NOT TO EXCEED 20 OF I PERCENT JOINT FITTINGS. SHOULD STREET
PRESSURE EXCEED 80 PSI, A PRESSURE REDUCING VALVE ASSEMBLY
SHALL BE INSTALLED. NO JOINTS SHALL BE ALLOWED UNDER
BUILDING SLAB. GATE VALVES SHALL BE BRONZE WITH ENDS TO
SUITE PIPE, NONRISING STEM FOR 150 PSI WORKING PRESSURE.
ABOVE
UNDERGROUND RIGID COPPER( TYPE L)SOLDERED
SANITARY
WASTE SEWER
UNDERGROUND CAST IRON SOIL PIPE & FITTINGS
OR OTHER APPROVED MATERIAL HUBLESS
ABOVE
GROUND
CAST IRON SOIL PIPE & FITTINGS
OR OTHER APPROVED MATERIAL HUBLESS
SANITARY
WASTE VENT
ABOVE
GROUND
CAST IRON SOIL PIPE & FITTINGS
OR OTHER APPROVED MATERIAL HUBLESS
LOW PRESSURE
GAS
UNDERGROUND SCHEDULE 40 BLACK STEEL WELDED PROVEIDE APPROVED GAS PRESSUSRE REGULATORS. NATURAL GAS
RIGHT
AND LEFT HAND NIPPLES AND COUPLINGS SHALL BE NEW BLACK
IRON, UNIONS SHALL NOT BE USED EXCEPT AT UNITS AND VAVLES.
ABOVE
UNDERGROUND SCHEDULE 40 BLACK STEEL WELDED
ABS PIPE MAY BE USED WHEN FIRST APPROVED BY THE
ADMINISTRATIVE AUTHORITY
ABS PIPE MAY BE USED WHEN FIRST APPROVED BY THE
ADMINISTRATIVE AUTHORITY
ABS PIPE MAY BE USED WHEN FIRST APPROVED BY THE
ADMINISTRATIVE AUTHORITY
PLUMBING ABBREVIATIONS
PLUMBING LEGEND
MISC. EQUIPMENT SCHEDULEMEP COMPONENT ANCHORAGE NOTE
PIPING SYSTEM BRACING NOTE
GENERAL NOTES
DOMESTIC WATER CALCULATION
REVISIONS
J
S
E
N
G
I
N
E
E
R
I
N
G
,
I
N
C
.
STAMP
P1
WE
S
T
F
I
E
L
D
M
A
L
L
40
0
S
.
B
A
L
D
W
I
N
A
V
E
.
S
U
I
T
E
B
3
A
&
S
B
4
,
AR
C
A
D
I
A
,
C
A
.
9
1
0
0
7
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
-
J
U
N
Y
'
S
B
A
K
E
D
12-08-2022 1
LEGEND
FLOOR PLAN (HOT & COLD)
1/4"=1'-0"
REVISIONS
J
S
E
N
G
I
N
E
E
R
I
N
G
,
I
N
C
.
STAMP
P2
WE
S
T
F
I
E
L
D
M
A
L
L
40
0
S
.
B
A
L
D
W
I
N
A
V
E
.
S
U
I
T
E
B
3
A
&
S
B
4
,
AR
C
A
D
I
A
,
C
A
.
9
1
0
0
7
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
-
J
U
N
Y
'
S
B
A
K
E
D
12-08-2022 1
FLOOR PLAN (GAS)
1/4"=1'-0"
FLOOR PLAN (WASTE & VENT)
1/4"=1'-0"
REVISIONS
J
S
E
N
G
I
N
E
E
R
I
N
G
,
I
N
C
.
STAMP
P3
WE
S
T
F
I
E
L
D
M
A
L
L
40
0
S
.
B
A
L
D
W
I
N
A
V
E
.
S
U
I
T
E
B
3
A
&
S
B
4
,
AR
C
A
D
I
A
,
C
A
.
9
1
0
0
7
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
-
J
U
N
Y
'
S
B
A
K
E
D
12-08-2022 1
3P
100A
M
H
EXISTING "MS"
2"C-4#3/0&1#6GND
277/480V, 3Ø,4W
T
A
(E)
(E)
(E)
EXISTING GND
45KVA XFMR
480-120/208V, 3PH, 4W
REVISIONS
J
S
E
N
G
I
N
E
E
R
I
N
G
,
I
N
C
.
STAMP
E1
WE
S
T
F
I
E
L
D
M
A
L
L
40
0
S
.
B
A
L
D
W
I
N
A
V
E
.
S
U
I
T
E
B
3
A
&
S
B
4
,
AR
C
A
D
I
A
,
C
A
.
9
1
0
0
7
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
-
J
U
N
Y
'
S
B
A
K
E
D
12-08-2022 1
(E)
(E)
(E)
(E)
(E)
POWER PLAN
1/4"=1'-0"
LIGHTING PLAN
1/4"=1'-0"
REVISIONS
J
S
E
N
G
I
N
E
E
R
I
N
G
,
I
N
C
.
STAMP
E2
WE
S
T
F
I
E
L
D
M
A
L
L
40
0
S
.
B
A
L
D
W
I
N
A
V
E
.
S
U
I
T
E
B
3
A
&
S
B
4
,
AR
C
A
D
I
A
,
C
A
.
9
1
0
0
7
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
-
J
U
N
Y
'
S
B
A
K
E
D
12-08-2022 1
REVISIONS
J
S
E
N
G
I
N
E
E
R
I
N
G
,
I
N
C
.
STAMP
E3
WE
S
T
F
I
E
L
D
M
A
L
L
40
0
S
.
B
A
L
D
W
I
N
A
V
E
.
S
U
I
T
E
B
3
A
&
S
B
4
,
AR
C
A
D
I
A
,
C
A
.
9
1
0
0
7
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
-
J
U
N
Y
'
S
B
A
K
E
D
12-08-2022 1