HomeMy WebLinkAbout400 S Baldwin Ave - 2023 - Taier ElectricalEastern LA & Orange Cty Mech
REGION 144
PHONE: (714) 503-0777
EMAIL: reg144@econair.com
FOR QUESTIONS, CALL THE
HOOD INFORMATION - JOB#6037327
1
2
3
4
5
L
R
5424
EX-2
5424
EX-2
5424
EX-2
4824
ES-VHB
4824
ES-VHB
ECON-AIR
ECON-AIR
ECON-AIR
ECON-AIR
ECON-AIR
12' 0"
11' 11"
7' 11"
4' 0"
3' 0"
600
DEG
600
DEG
600
DEG
700
DEG
700
DEG
I
I
I
II
II
HEAVY
HEAVY
HEAVY
N/A
N/A
300
302
227
200
200
3600
3600
1800
800
600
4"
4"
4"
4"
4"
18"
18"
14"
12"
10"
3600
3600
1800
800
600
2037
2037
1684
1019
1100
-0.685"
-0.692"
-0.387"
-0.118"
-0.090"
430 SS
WHERE EXPOSED
430 SS
WHERE EXPOSED
430 SS
WHERE EXPOSED
430 SS
100%
430 SS
100%
LEFT
RIGHT
ALONE
ALONE
ALONE
ALONE
ALONE
ALONE
ALONE
ALONE
HOOD
NO
TAG MODEL MANUFACTURER LENGTH
MAX
COOKING
TEMP
TYPE
APPLIANCE
DUTY
DESIGN
CFM/FT
TOTAL
EXH CFM
EXHAUST PLENUM
RISER(S)
WIDTH LENG HEIGHT DIA CFM VEL SP
HOOD
CONSTRUCTION
HOOD CONFIG
END TO
END
ROW
HOOD INFORMATION
1
2
3
4
5
L
R
SS BAFFLE WITH
HANDLES
SS BAFFLE WITH
HANDLES
SS BAFFLE WITH
HANDLES
9
8
5
20"
20"
20"
16"
16"
16"
30%
30%
30%
4
4
3
0
0
L55 SERIES E26
L55 SERIES E26
L55 SERIES E26
NO
NO
NO
LEFT
WALL MNT
LEFT
12"x54"x24"
12"x60"x24"
12"x54"x24"
TANK FS
TANK FS
4.0/4.0/4.0/4.0
4.0
SC-E200111MA
SC-E100111MA
1 LIGHT
1 FAN
1 LIGHT
1 FAN
YES
YES
YES
NO
NO
600
LBS
433
LBS
527
LBS
155
LBS
139
LBS
HOOD
NO
TAG
FILTER(S)
TYPE QTY HEIGHT LENGTH
EFFICIENCY @ 7
MICRONS
LIGHT(S)
QTY TYPE
WIRE
GUARD
UTILITY CABINET(S)
LOCATION SIZE
FIRE SYSTEM
TYPE SIZE
ELECTRICAL
MODEL #
SWITCHES
QUANTITY
FIRE
SYSTEM
PIPING
HOOD
HANGING
WEIGHT
HOOD OPTIONS
1
2
3
L
R
LEFT VERTICAL END PANEL 27" TOP WIDTH, 21" BOTTOM WIDTH, 80" HIGH INSULATED 430
SS.
RIGHT END STANDOFF (FINISHED) 1" WIDE 54" LONG INSULATED.
RIGHT WALL AS END PANEL.
RIGHT END STANDOFF (FINISHED) 1" WIDE 54" LONG INSULATED.
RIGHT WALL AS END PANEL.
HOOD
NO
TAG OPTION
WALL-MOUNT UTILITY CABINET
1 WALL MNT 12"x60"x24"TANK FS 4.0/4.0/4.0/4.0 500.00 LBS
UTILITY CABINET(S)
HOOD
NO
LOCATION SIZE
FIRE SYSTEM
TYPE SIZE
ELECTRICAL
MODEL #
SWITCHES
QUANTITY
WEIGHT
7' 11"NOM./7' 11.00"OD.
9'-0.00" OVERALL LENGTH
54"
12"
1" LAYER OF INSULATION
FACTORY INSTALLED IN
1.00" END STANDOFF MEETS
0" REQUIREMENTS CLEARANCE
TO COMBUSTIBLE SURFACES.
1"
§
47 1/2"47 1/2"
11"
∅14"
U.L. LISTED L55 SERIES E26 CANOPY
LIGHT FIXTURE - HIGH TEMP ASSEMBLY.
INSTALLER MUST CONFIRM HOOD IS INSTALLED SUCH
THAT THE SPECIFIED WALL, ACTING AS AN END PANEL,
IS MATED TIGHT TO THE CORRECT END OF HOOD TO
ACHIEVE A REDUCED MINIMUM EXHAUST CFM LISTING.
NON-COMPLIANCE WILL NULLIFY THE ETL LISTING,
VOID THE MANUFACTURER'S WARRANTY, AND HOLD THE
CONTRACTOR LIABLE FOR ANY AND ALL LOSSES, COSTS,
AND EXPENSES RELATED TO THE NON-CONFORMANCE OF
THE MANUFACTURER'S SPECIFIED INSTRUCTION. THE
WALL ACTING AS AN END PANEL MUST EXTEND NO LESS
THAN 20" FROM THE INTERSECTING WALL ON WHICH HOOD
IS MOUNTED AND MUST EXTEND NO LESS THAN 20" UNDER
BOTTOM OF HOOD TO BE ELIGIBLE FOR REDUCED
MINIMUM EXHAUST CFM LISTING.
PLAN VIEW - HOOD #3
7' 11.00" LONG 5424EX-2
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUT.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUTS.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL ALL-THREAD.
HOOD CORNER
HANGING ANGLE
(WEIGHT BEARING
ANCHOR POINT
FOR HOOD).
HOOD CORNER
HANGING ANGLE
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUTS.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
ASSEMBLY INSTRUCTIONS
HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI
GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING
ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5
(MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI
GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE
DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING
ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF
EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE
ALL HEX NUTS TO 57 FT-LBS.
(HARDWARE BY INSTALLER)
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUT.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
FULL LENGTH
HANGING ANGLE
(WEIGHT BEARING
ANCHOR POINT
FOR HOOD).
FULL LENGTH
HANGING ANGLE
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL ALL-THREAD.
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUTS.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUT.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
ASSEMBLY INSTRUCTIONS
HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI
GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING
ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5
(MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI
GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE
DOUBLED HEX NUT CONFIGURATION ABOVE CEILING
ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS
ACCEPTABLE FOR FULL LENGTH HANGING ANGLES.
MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM
HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS.
(HARDWARE BY INSTALLER)
3" INTERNAL STANDOFF.
GREASE DRAIN
WITH REMOVABLE CUP.
SEE HOOD TABLE.
§
EXHAUST RISER.
HANGING ANGLE.
L55 SERIES E26 CANOPY LIGHT FIXTURE -
HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL
AND SHOCK RESISTANT GLOBE (L55 FIXTURE).
RIGHT WALL AS END PANEL.
EQUIPMENT
BY OTHERS.
48.0" MAX.
80"
24" NOM.
54"
SECTION VIEW - MODEL 5424EX-2
HOOD - #3
IT IS THE RESPONSIBILITY
OF THE ARCHITECT/OWNER TO
ENSURE THAT THE HOOD CLEARANCE
FROM LIMITED-COMBUSTIBLE
AND COMBUSTIBLE MATERIALS
IS IN COMPLIANCE WITH
LOCAL CODE REQUIREMENTS.
20" SS BAFFLE WITH
HANDLES AND HOOK.
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
e
c
o
n
a
i
r
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NFP
A
WIT
H
IN
S
LI
D
TE
R
C
U
S
MASTER DRAWING
3/4" = 1'-0"
6037327
1
JG
6/6/2023
Ea
s
t
e
r
n
L
A
&
O
r
a
n
g
e
C
t
y
M
e
c
h
30
0
2
D
o
w
A
v
e
n
u
e
,
S
u
i
t
e
2
0
2
,
T
u
s
t
i
n
,
C
A
,
9
2
7
8
0
P
H
O
N
E
:
(
7
1
4
)
5
0
3
-
0
7
7
7
E
M
A
I
L
:
r
e
g
1
4
4
@
e
c
o
n
a
i
r
.
c
o
m
Ta
i
e
r
R
e
s
t
a
u
r
a
n
t
-
A
r
c
a
d
i
a
Ar
c
a
d
i
a
,
C
A
,
9
1
0
0
7
40
0
S
o
u
t
h
B
a
l
d
w
i
n
A
v
e
n
u
e
,
S
u
i
t
e
2
3
1
ACTUAL DIMENSIONS
19-5/8" x 19-5/8" x 1-7/8"
19-5/8" x 15-5/8" x 1-7/8"
15-5/8" x 19-5/8" x 1-7/8"
15-5/8" x 15-5/8" x 1-7/8"
FILTER INFORMATION
Region 144
20 x 20
16 x 20
16 x 16
20 x 16
NOM. SIZE
(H x W)
2.28 11
1.78
1.39
1.78
9.1
7.4
8.9
(SQ. FEET)
FREE AREA
(H x W x D)(LBS)
WEIGHT
SOUTHERN CALIFORNIA OFFICE
TUSTIN, CA 92780
PHONE: (714) 503 - 0777
REG144@CAPTIVEAIRE.COM
FOR QUESTIONS, CALL THE
HANGING ANGLE
THROUGH ANOTHER
CONNECTED TO ROOF JOIST
1/2" DIA. ALL THREAD ROD
AND WASHER - ONE ABOVE
1/2" DIA. HEAVY DUTY NUT
AND ONE BELOW HANGING ANGLE
ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR
CORNER HANGING ANGLE DETAIL ND-2
HANGING ANGLE IS PRE-PUNCHED AT FACTORY
STEEL HANGING ANGLE
3002 DOW AVE., SUITE 410
CAPTRATE
R
RCAPTIVEAIRE
CAPTRATE & KLEEN-GARD FILTERS
TE
A
ARE BUILT IN COMPLIANCE WITH
INT. MECH. CODE (IMC)
UL STANDARD #1046
NSF
NSF STANDARD #2
O
NFPA #96
CH
B
N
RAN I
,OR M
.
YR
OR
LAIGNTSB
AT
UL 710 & ULC710 STANDARDS
E.T.L. LISTED 102900319PRT-001
CAPTIVE-AIRE HOODS ARE
BUILT IN COMPLIANCE WITH
NFPA #96
ACTUAL DIMENSIONS
19-5/8" x 19-5/8" x 1-7/8"
19-5/8" x 15-5/8" x 1-7/8"
15-5/8" x 19-5/8" x 1-7/8"
15-5/8" x 15-5/8" x 1-7/8"
2.28
1.78
1.39
1.78
(SQ. FEET)
FREE AREA
(H x W x D)(LBS)
WEIGHT
10
12
12
1520 x 20
16 x 20
16 x 16
20 x 16
NOM. SIZE
(H x W)
ACTUAL DIMENSIONS
19-5/8" x 19-5/8" x 1-7/8"
19-5/8" x 15-5/8" x 1-7/8"
15-5/8" x 19-5/8" x 1-7/8"
15-5/8" x 15-5/8" x 1-7/8"
2.23
1.73
1.35
1.73
(SQ. FEET)
FREE AREA
(H x W x D)(LBS)
WEIGHT
20 x 20
16 x 20
16 x 16
20 x 16
NOM. SIZE
(H x W)
GREASE-STOP SOLO
FILTER INFORMATION
CAPTRATE
R
R
GREASE-STOP COMBO
FILTER INFORMATION
KLEEN-GARD
R
SS BAFFLE TYPE
11
9.1
7.4
8.9
SLI DTE
R ACCORDANCE
No. 96
NFPA
WITH
BUILT
IN
WITH
NFPA
No. 96
IN
ACCORDANCE
BUILT
SLI DTE
R
LIGHT/FAN CONTROL INTERFACE
120V 15AMP CONTROL INPUT
BUILDING ALARM
120V 15AMP LIGHT INPUT
PRE-WIRED TO LIGHTS
(TYPICAL CONNECTIONS, REFER TO
DETAILED WIRING DIAGRAMS FOR
RESPONSIBILITY AND CONNECTIONS)
ELECTRICAL HOOD CONTROL BOX
UTILITY CABINET
INPUT FOR EXHAUST/SUPPLY FAN
SHUNT TRIP BREAKER (BY ELECTRICIAN)
OUTPUT FOR EXHAUST/SUPPLY FAN
CAT-5 PREWIRED AT FACTORY
TANK FIRE SYSTEM
BUILDING TROUBLE
12' 0"NOM./12' 0.00"OD.
13'-0.00" OVERALL LENGTH
12"
§
72"72"
12"
∅18"
U.L. LISTED L55 SERIES E26 CANOPY
LIGHT FIXTURE - HIGH TEMP ASSEMBLY.
11' 11"NOM./11' 11.00"OD.
12'-0.00" OVERALL LENGTH
54"
1" LAYER OF INSULATION
FACTORY INSTALLED IN
1.00" END STANDOFF MEETS
0" REQUIREMENTS CLEARANCE
TO COMBUSTIBLE SURFACES.
1"
3"
§
71 1/2"71 1/2"
12"
∅18"
U.L. LISTED L55 SERIES E26 CANOPY
LIGHT FIXTURE - HIGH TEMP ASSEMBLY.
INSTALLER MUST CONFIRM HOOD IS INSTALLED SUCH
THAT THE SPECIFIED WALL, ACTING AS AN END PANEL,
IS MATED TIGHT TO THE CORRECT END OF HOOD TO
ACHIEVE A REDUCED MINIMUM EXHAUST CFM LISTING.
NON-COMPLIANCE WILL NULLIFY THE ETL LISTING,
VOID THE MANUFACTURER'S WARRANTY, AND HOLD THE
CONTRACTOR LIABLE FOR ANY AND ALL LOSSES, COSTS,
AND EXPENSES RELATED TO THE NON-CONFORMANCE OF
THE MANUFACTURER'S SPECIFIED INSTRUCTION. THE
WALL ACTING AS AN END PANEL MUST EXTEND NO LESS
THAN 20" FROM THE INTERSECTING WALL ON WHICH HOOD
IS MOUNTED AND MUST EXTEND NO LESS THAN 20" UNDER
BOTTOM OF HOOD TO BE ELIGIBLE FOR REDUCED
MINIMUM EXHAUST CFM LISTING.
25'-0.00" OVERALL LENGTH
PLAN VIEW - HOOD #1 (L)
12' 0.00" LONG 5424EX-2
NOTE: ADDITIONAL HANGING ANGLES PROVIDED FOR HOODS 12' AND LONGER.
PLAN VIEW - HOOD #2 (R)
11' 11.00" LONG 5424EX-2
3" INTERNAL STANDOFF.
GREASE DRAIN
WITH REMOVABLE CUP.
SEE HOOD TABLE.
§
EXHAUST RISER.
HANGING ANGLE.
L55 SERIES E26 CANOPY LIGHT FIXTURE -
HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL
AND SHOCK RESISTANT GLOBE (L55 FIXTURE).
20"
4"
4 1/2"
21"
27"
80"
LEFT VERTICAL END PANEL
WITH ADJUSTABLE LEGS.
GAS CHASE CUTOUT
(FOR GAS AND POWER LINES).
EQUIPMENT
BY OTHERS.
48.0" MAX.
80"
24" NOM.
54"
SECTION VIEW - MODEL 5424EX-2
HOOD - #1 (L)
IT IS THE RESPONSIBILITY
OF THE ARCHITECT/OWNER TO
ENSURE THAT THE HOOD CLEARANCE
FROM LIMITED-COMBUSTIBLE
AND COMBUSTIBLE MATERIALS
IS IN COMPLIANCE WITH
LOCAL CODE REQUIREMENTS.
20" SS BAFFLE WITH
HANDLES AND HOOK.
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
e
c
o
n
a
i
r
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NFP
A
WIT
H
IN
S
LI
D
TE
R
C
U
S
MASTER DRAWING
3/4" = 1'-0"
6037327
2
JG
6/6/2023
Ea
s
t
e
r
n
L
A
&
O
r
a
n
g
e
C
t
y
M
e
c
h
30
0
2
D
o
w
A
v
e
n
u
e
,
S
u
i
t
e
2
0
2
,
T
u
s
t
i
n
,
C
A
,
9
2
7
8
0
P
H
O
N
E
:
(
7
1
4
)
5
0
3
-
0
7
7
7
E
M
A
I
L
:
r
e
g
1
4
4
@
e
c
o
n
a
i
r
.
c
o
m
Ta
i
e
r
R
e
s
t
a
u
r
a
n
t
-
A
r
c
a
d
i
a
Ar
c
a
d
i
a
,
C
A
,
9
1
0
0
7
40
0
S
o
u
t
h
B
a
l
d
w
i
n
A
v
e
n
u
e
,
S
u
i
t
e
2
3
1
LIGHT/FAN CONTROL INTERFACE
120V 15AMP CONTROL INPUT
BUILDING ALARM
120V 15AMP LIGHT INPUT
PRE-WIRED TO LIGHTS
(TYPICAL CONNECTIONS, REFER TO
DETAILED WIRING DIAGRAMS FOR
RESPONSIBILITY AND CONNECTIONS)
ELECTRICAL HOOD CONTROL BOX
UTILITY CABINET
INPUT FOR EXHAUST/SUPPLY FAN
SHUNT TRIP BREAKER (BY ELECTRICIAN)
OUTPUT FOR EXHAUST/SUPPLY FAN
CAT-5 PREWIRED AT FACTORY
BUILDING TROUBLE
ACTUAL DIMENSIONS
19-5/8" x 19-5/8" x 1-7/8"
19-5/8" x 15-5/8" x 1-7/8"
15-5/8" x 19-5/8" x 1-7/8"
15-5/8" x 15-5/8" x 1-7/8"
FILTER INFORMATION
Region 144
20 x 20
16 x 20
16 x 16
20 x 16
NOM. SIZE
(H x W)
2.28 11
1.78
1.39
1.78
9.1
7.4
8.9
(SQ. FEET)
FREE AREA
(H x W x D)(LBS)
WEIGHT
SOUTHERN CALIFORNIA OFFICE
TUSTIN, CA 92780
PHONE: (714) 503 - 0777
REG144@CAPTIVEAIRE.COM
FOR QUESTIONS, CALL THE
HANGING ANGLE
THROUGH ANOTHER
CONNECTED TO ROOF JOIST
1/2" DIA. ALL THREAD ROD
AND WASHER - ONE ABOVE
1/2" DIA. HEAVY DUTY NUT
AND ONE BELOW HANGING ANGLE
ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR
CORNER HANGING ANGLE DETAIL ND-2
HANGING ANGLE IS PRE-PUNCHED AT FACTORY
STEEL HANGING ANGLE
3002 DOW AVE., SUITE 410
CAPTRATE
R
RCAPTIVEAIRE
CAPTRATE & KLEEN-GARD FILTERS
TE
A
ARE BUILT IN COMPLIANCE WITH
INT. MECH. CODE (IMC)
UL STANDARD #1046
NSF
NSF STANDARD #2
O
NFPA #96
CH
B
N
RAN I
,OR M
.
YR
OR
LAIGNTSB
AT
UL 710 & ULC710 STANDARDS
E.T.L. LISTED 102900319PRT-001
CAPTIVE-AIRE HOODS ARE
BUILT IN COMPLIANCE WITH
NFPA #96
ACTUAL DIMENSIONS
19-5/8" x 19-5/8" x 1-7/8"
19-5/8" x 15-5/8" x 1-7/8"
15-5/8" x 19-5/8" x 1-7/8"
15-5/8" x 15-5/8" x 1-7/8"
2.28
1.78
1.39
1.78
(SQ. FEET)
FREE AREA
(H x W x D)(LBS)
WEIGHT
10
12
12
1520 x 20
16 x 20
16 x 16
20 x 16
NOM. SIZE
(H x W)
ACTUAL DIMENSIONS
19-5/8" x 19-5/8" x 1-7/8"
19-5/8" x 15-5/8" x 1-7/8"
15-5/8" x 19-5/8" x 1-7/8"
15-5/8" x 15-5/8" x 1-7/8"
2.23
1.73
1.35
1.73
(SQ. FEET)
FREE AREA
(H x W x D)(LBS)
WEIGHT
20 x 20
16 x 20
16 x 16
20 x 16
NOM. SIZE
(H x W)
GREASE-STOP SOLO
FILTER INFORMATION
CAPTRATE
R
R
GREASE-STOP COMBO
FILTER INFORMATION
KLEEN-GARD
R
SS BAFFLE TYPE
11
9.1
7.4
8.9
SLI DTE
R ACCORDANCE
No. 96
NFPA
WITH
BUILT
IN
WITH
NFPA
No. 96
IN
ACCORDANCE
BUILT
SLI DTE
R
UTILITY CABINET HOUSES
FIRE SUPPRESSION
MEASURES 60" x 24" x 12"
4' 0"NOM./4' 0.00"OD.
48"
§
24"24"
24"
∅12"
PLAN VIEW - HOOD #4
4' 0.00" LONG 4824ES-VHB
3' 0"NOM./3' 0.00"OD.
48"
§
18"18"
24"
∅10"
PLAN VIEW - HOOD #5
3' 0.00" LONG 4824ES-VHB
SEE HOOD TABLE.
§
EXHAUST RISER.
HANGING ANGLE.
EQUIPMENT
BY OTHERS.
80"
24" NOM.
48"
SECTION VIEW - MODEL 4824ES-VHB
HOOD - #4
SEE HOOD TABLE.
§
EXHAUST RISER.
HANGING ANGLE.
EQUIPMENT
BY OTHERS.
80"
24" NOM.
48"
SECTION VIEW - MODEL 4824ES-VHB
HOOD - #5
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
e
c
o
n
a
i
r
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NFP
A
WIT
H
IN
S
LI
D
TE
R
C
U
S
MASTER DRAWING
3/4" = 1'-0"
6037327
3
JG
6/6/2023
Ea
s
t
e
r
n
L
A
&
O
r
a
n
g
e
C
t
y
M
e
c
h
30
0
2
D
o
w
A
v
e
n
u
e
,
S
u
i
t
e
2
0
2
,
T
u
s
t
i
n
,
C
A
,
9
2
7
8
0
P
H
O
N
E
:
(
7
1
4
)
5
0
3
-
0
7
7
7
E
M
A
I
L
:
r
e
g
1
4
4
@
e
c
o
n
a
i
r
.
c
o
m
Ta
i
e
r
R
e
s
t
a
u
r
a
n
t
-
A
r
c
a
d
i
a
Ar
c
a
d
i
a
,
C
A
,
9
1
0
0
7
40
0
S
o
u
t
h
B
a
l
d
w
i
n
A
v
e
n
u
e
,
S
u
i
t
e
2
3
1
ACTUAL DIMENSIONS
19-5/8" x 19-5/8" x 1-7/8"
19-5/8" x 15-5/8" x 1-7/8"
15-5/8" x 19-5/8" x 1-7/8"
15-5/8" x 15-5/8" x 1-7/8"
FILTER INFORMATION
Region 144
20 x 20
16 x 20
16 x 16
20 x 16
NOM. SIZE
(H x W)
2.28 11
1.78
1.39
1.78
9.1
7.4
8.9
(SQ. FEET)
FREE AREA
(H x W x D)(LBS)
WEIGHT
SOUTHERN CALIFORNIA OFFICE
TUSTIN, CA 92780
PHONE: (714) 503 - 0777
REG144@CAPTIVEAIRE.COM
FOR QUESTIONS, CALL THE
HANGING ANGLE
THROUGH ANOTHER
CONNECTED TO ROOF JOIST
1/2" DIA. ALL THREAD ROD
AND WASHER - ONE ABOVE
1/2" DIA. HEAVY DUTY NUT
AND ONE BELOW HANGING ANGLE
ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR
CORNER HANGING ANGLE DETAIL ND-2
HANGING ANGLE IS PRE-PUNCHED AT FACTORY
STEEL HANGING ANGLE
3002 DOW AVE., SUITE 410
CAPTRATE
R
RCAPTIVEAIRE
CAPTRATE & KLEEN-GARD FILTERS
TE
A
ARE BUILT IN COMPLIANCE WITH
INT. MECH. CODE (IMC)
UL STANDARD #1046
NSF
NSF STANDARD #2
O
NFPA #96
CH
B
N
RAN I
,OR M
.
YR
OR
LAIGNTSB
AT
UL 710 & ULC710 STANDARDS
E.T.L. LISTED 102900319PRT-001
CAPTIVE-AIRE HOODS ARE
BUILT IN COMPLIANCE WITH
NFPA #96
ACTUAL DIMENSIONS
19-5/8" x 19-5/8" x 1-7/8"
19-5/8" x 15-5/8" x 1-7/8"
15-5/8" x 19-5/8" x 1-7/8"
15-5/8" x 15-5/8" x 1-7/8"
2.28
1.78
1.39
1.78
(SQ. FEET)
FREE AREA
(H x W x D)(LBS)
WEIGHT
10
12
12
1520 x 20
16 x 20
16 x 16
20 x 16
NOM. SIZE
(H x W)
ACTUAL DIMENSIONS
19-5/8" x 19-5/8" x 1-7/8"
19-5/8" x 15-5/8" x 1-7/8"
15-5/8" x 19-5/8" x 1-7/8"
15-5/8" x 15-5/8" x 1-7/8"
2.23
1.73
1.35
1.73
(SQ. FEET)
FREE AREA
(H x W x D)(LBS)
WEIGHT
20 x 20
16 x 20
16 x 16
20 x 16
NOM. SIZE
(H x W)
GREASE-STOP SOLO
FILTER INFORMATION
CAPTRATE
R
R
GREASE-STOP COMBO
FILTER INFORMATION
KLEEN-GARD
R
SS BAFFLE TYPE
11
9.1
7.4
8.9
SLI DTE
R ACCORDANCE
No. 96
NFPA
WITH
BUILT
IN
WITH
NFPA
No. 96
IN
ACCORDANCE
BUILT
SLI DTE
R
FIRE SYSTEM INFORMATION - JOB#6037327
1
2
TANK FS
TANK FS
4.0/4.0/4.0/4.0
4.0
74
20
WALL UTILITY CABINET LEFT
FIRE CABINET LEFT
N/A
LEFT, HOOD 3
FIRE
SYSTEM
NO
TAG TYPE SIZE
FLOW
POINTS
INSTALLATION
SYSTEM LOCATION ON HOOD
12"
∅18"
HOOD FRONT
HOOD BACK
HOOD # 1 (L) JOB # 6037327 FS # 1
MODEL: ND-2 SIZE: 54"x24" LENGTH: 12' 0"
TA
N
K
O
V
E
R
L
A
P
P
I
N
G
PR
O
T
E
C
T
I
O
N
-
3
0
HI
G
H
P
R
O
X
I
M
I
T
Y
28
1
.
0
0
"
L
X
3
0
.
0
0
"
D
DUCT
S
360
OL-F
OL-F OL-F
25.00"25.00"
21.50"
OL-F
21.50"
OL-F
21.50"
OL-F
21.50"
OL-F
21.50"
OL-F
21.50"
OL-F
21.50"
OL-F
21.50"
OL-F
21.50"
OL-F
21.50"
OL-F
NOZZLE HEIGHT
35-50" FROM
COOKING SURFACE.
(45.25")
18.00"28.56"28.56"28.56"28.56"11.78"16.78"28.56"28.56"28.56"28.56"12.00"
SLPCON-03FT
KIT
SLPCON-10FT
KIT
12.00"
48.00"
1
631
1
1
3
3
6
7
6
2 5
24.00"
48.00"
12"
∅18"
HOOD FRONT
HOOD BACK
HOOD # 2 (R) JOB # 6037327 FS # 1
MODEL: ND-2 SIZE: 54"x24" LENGTH: 11' 11"
DUCT
S
360
OL-F
OL-F OL-F
SLPCON-30FT
KIT
TO HOOD# 1 WALL-UC
ALTERNATE FIELD-CONNECTION POINT
PL
E
N
U
M
PL
E
N
U
M
TO HOOD# 1 WALL-UC
PL
E
N
U
M
PL
E
N
U
M
NOTES
- FIELD PIPE DROPS AS SHOWN
PIPING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS.
- FIELD INSTALLED DROP: FACTORY WILL PROVIDE QTY 2 60IN LONG PIECES OF CHROME
PLATED PIPING SHIPPED LOOSE TO BE FIELD-INSTALLED.
- SHIP LOOSE DROP: FACTORY WILL PROVIDE THE EXACT CHROME PIPE LENGTH NEEDED
SHIPPED LOOSE TO BE FIELD-INSTALLED.
- RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING,
SALAMANDERS, ETC.
- OVERLAPPING COVERAGE SHALL NOT BE USED ON ANY APPLIANCE WITH AN OBSTRUCTION.
- IF APPLICABLE, EXTENDED PRE-PIPED DROPS ARE SHIPPED LOOSE.
- FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD.
- APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE
SIZE, NOT THE OVERALL APPLIANCE SIZE.
- THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS.
- OL-F NOZZLE PART NUMBER REPLACES 3070-3/8H-10-SS
JOB #: 6037327.
JOB NAME: TAIER RESTAURANT - ARCADIA.
SYSTEM SIZE: TANK-SP-4-WC TOTAL FP REQUIRED: 74.
HOOD # 1 12' 0.00" LONG x 54" WIDE x 24" HIGH.
RISER # 1 SIZE: 18" DIA.
HOOD # 1 METAL BLOW-OFF CAPS INCLUDED.
HOOD # 2 11' 11.00" LONG x 54" WIDE x 24" HIGH.
RISER # 1 SIZE: 18" DIA.
HOOD # 2 METAL BLOW-OFF CAPS INCLUDED.
- HEAVY-DUTY APPLIANCES (RATED 600°F) WILL REQUIRE AN ADDITIONAL
DOWNSTREAM FIRESTAT IN THE EVENT THAT THE DUCTWORK CONTAINS ANY
HORIZONTAL RUNS OVER 25 FT IN LENGTH.
- MEDIUM TO LIGHT-DUTY APPLIANCES (RATED 450°F) WILL NOT REQUIRE
ANY ADDITIONAL DOWNSTREAM DETECTION.
PRESSURE SUPERVISION SWITCH.
PRIMARY ACTUATOR RELEASE.
4 GALLON TANK.
7
6
5
4
2
1
LEGEND - FIRE CABINET TANK SYSTEM
PRIMARY HOSE ASSEMBLY.
SECONDARY ACTUATOR RELEASE.3
SECONDARY HOSE ASSEMBLY.
REMOTE MANUAL ACTUATION DEVICE.
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
e
c
o
n
a
i
r
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NFP
A
WIT
H
IN
S
LI
D
TE
R
C
U
S
MASTER DRAWING
1/2" = 1'-0"
6037327
4
JG
6/6/2023
Ea
s
t
e
r
n
L
A
&
O
r
a
n
g
e
C
t
y
M
e
c
h
30
0
2
D
o
w
A
v
e
n
u
e
,
S
u
i
t
e
2
0
2
,
T
u
s
t
i
n
,
C
A
,
9
2
7
8
0
P
H
O
N
E
:
(
7
1
4
)
5
0
3
-
0
7
7
7
E
M
A
I
L
:
r
e
g
1
4
4
@
e
c
o
n
a
i
r
.
c
o
m
Ta
i
e
r
R
e
s
t
a
u
r
a
n
t
-
A
r
c
a
d
i
a
Ar
c
a
d
i
a
,
C
A
,
9
1
0
0
7
40
0
S
o
u
t
h
B
a
l
d
w
i
n
A
v
e
n
u
e
,
S
u
i
t
e
2
3
1
11"
∅14"
HOOD FRONT
HOOD BACK
HOOD # 3 JOB # 6037327 FS # 2
MODEL: ND-2 SIZE: 54"x24" LENGTH: 7' 11"
TA
N
K
O
V
E
R
L
A
P
P
I
N
G
PR
O
T
E
C
T
I
O
N
-
3
6
HI
G
H
P
R
O
X
I
M
I
T
Y
89
.
0
0
"
L
X
3
0
.
0
0
"
D
DUCT
S
360
OL-F
OL-F
25.00"
21.50"
OL-F
21.50"
OL-F
21.50"
OL-F
NOZZLE HEIGHT
35-50" FROM
COOKING SURFACE.
(45.25")
18.00"32.50"32.50"12.00"
7
1 2 5
PL
E
N
U
M
NOTES
- FIELD PIPE DROPS AS SHOWN
PIPING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS.
- FIELD INSTALLED DROP: FACTORY WILL PROVIDE QTY 2 60IN LONG PIECES OF CHROME
PLATED PIPING SHIPPED LOOSE TO BE FIELD-INSTALLED.
- SHIP LOOSE DROP: FACTORY WILL PROVIDE THE EXACT CHROME PIPE LENGTH NEEDED
SHIPPED LOOSE TO BE FIELD-INSTALLED.
- RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING,
SALAMANDERS, ETC.
- OVERLAPPING COVERAGE SHALL NOT BE USED ON ANY APPLIANCE WITH AN OBSTRUCTION.
- IF APPLICABLE, EXTENDED PRE-PIPED DROPS ARE SHIPPED LOOSE.
- FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD.
- APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE
SIZE, NOT THE OVERALL APPLIANCE SIZE.
- THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS.
- OL-F NOZZLE PART NUMBER REPLACES 3070-3/8H-10-SS
JOB #: 6037327.
JOB NAME: TAIER RESTAURANT - ARCADIA.
SYSTEM SIZE: TANK-SP-1 TOTAL FP REQUIRED: 20.
HOOD # 3 7' 11.00" LONG x 54" WIDE x 24" HIGH.
RISER # 1 SIZE: 14" DIA.
HOOD # 3 METAL BLOW-OFF CAPS INCLUDED.
- HEAVY-DUTY APPLIANCES (RATED 600°F) WILL REQUIRE AN ADDITIONAL
DOWNSTREAM FIRESTAT IN THE EVENT THAT THE DUCTWORK CONTAINS ANY
HORIZONTAL RUNS OVER 25 FT IN LENGTH.
- MEDIUM TO LIGHT-DUTY APPLIANCES (RATED 450°F) WILL NOT REQUIRE
ANY ADDITIONAL DOWNSTREAM DETECTION.
PRESSURE SUPERVISION SWITCH.
PRIMARY ACTUATOR RELEASE.
4 GALLON TANK.
7
6
5
4
2
1
LEGEND - FIRE CABINET TANK SYSTEM
PRIMARY HOSE ASSEMBLY.
SECONDARY ACTUATOR RELEASE.3
SECONDARY HOSE ASSEMBLY.
REMOTE MANUAL ACTUATION DEVICE.
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
e
c
o
n
a
i
r
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NFP
A
WIT
H
IN
S
LI
D
TE
R
C
U
S
MASTER DRAWING
1/2" = 1'-0"
6037327
5
JG
6/6/2023
Ea
s
t
e
r
n
L
A
&
O
r
a
n
g
e
C
t
y
M
e
c
h
30
0
2
D
o
w
A
v
e
n
u
e
,
S
u
i
t
e
2
0
2
,
T
u
s
t
i
n
,
C
A
,
9
2
7
8
0
P
H
O
N
E
:
(
7
1
4
)
5
0
3
-
0
7
7
7
E
M
A
I
L
:
r
e
g
1
4
4
@
e
c
o
n
a
i
r
.
c
o
m
Ta
i
e
r
R
e
s
t
a
u
r
a
n
t
-
A
r
c
a
d
i
a
Ar
c
a
d
i
a
,
C
A
,
9
1
0
0
7
40
0
S
o
u
t
h
B
a
l
d
w
i
n
A
v
e
n
u
e
,
S
u
i
t
e
2
3
1
FLOW.
ELECTRIC GAS VALVE.
STRAINER.
4" MIN.
EXHAUST FAN INFORMATION - JOB#6037327
1
2
3
4
5
1
1
1
1
1
DU180HFA
DU180HFA
DU85HFA
DU33HFA
DU33HFA
CAPTIVEAIRE
CAPTIVEAIRE
CAPTIVEAIRE
CAPTIVEAIRE
CAPTIVEAIRE
3600
3600
1800
800
600
1.250
1.250
0.750
0.400
0.400
1336
1336
1242
1463
1232
TEFC,PREMIUM
TEFC,PREMIUM
TEAO-ECM
TEAO-ECM
TEAO-ECM
3.000
3.000
0.750
0.333
0.333
1.8420
1.8420
0.3730
0.2090
0.1250
3
3
1
1
1
208
208
115
115
115
9.4
9.4
8.9
4.3
4.3
831 FPM
831 FPM
570 FPM
396 FPM
297 FPM
181
181
94
68
68
21.7
21.7
10.3
14.8
10.6
FAN
UNIT
NO
TAG QTY FAN UNIT MODEL #MANUFACTURER CFM ESP RPM
MOTOR
ENCL
HP BHP PHASE VOLT FLA
DISCHARGE
VELOCITY
WEIGHT
(LBS)
SONES
FAN OPTIONS
1
2
3
4
5
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
GREASE BOX
FAN BASE CERAMIC SEAL - INSTALLED AT PLANT - FOR GREASE DUCTS
2 YEAR PARTS WARRANTY
GREASE BOX
FAN BASE CERAMIC SEAL - INSTALLED AT PLANT - FOR GREASE DUCTS
2 YEAR PARTS WARRANTY
GREASE BOX
FAN BASE CERAMIC SEAL - INSTALLED AT PLANT - FOR GREASE DUCTS
ECM WIRING PACKAGE - PWM SIGNAL FROM ECPMO3 PREWIRE (TELCO MOTOR), CCW ROTATION
2 YEAR PARTS WARRANTY
ECM WIRING PACKAGE - MANUAL OR 0-10VDC REFERENCE SPEED CONTROL -RTC- (TELCO
MOTOR), CCW ROTATION
I 15-BDD DAMPER
2 YEAR PARTS WARRANTY
ECM WIRING PACKAGE - MANUAL OR 0-10VDC REFERENCE SPEED CONTROL -RTC- (TELCO
MOTOR), CCW ROTATION
I 15-BDD DAMPER
2 YEAR PARTS WARRANTY
FAN
UNIT
NO
TAG QTY DESCRIPTION
FAN ACCESSORIES
1
2
3
4
5
YES
YES
YES
YES
YES
FAN
UNIT
NO
TAG
EXHAUST
GREASE
CUP
GRAVITY
DAMPER
WALL
MOUNT
SUPPLY
SIDE
DISCHARGE
GRAVITY
DAMPER
MOTORIZED
DAMPER
WALL
MOUNT
CURB ASSEMBLIES
1
2
3
4
5
# 1
# 2
# 3
# 4
# 5
41 LBS
41 LBS
36 LBS
18 LBS
18 LBS
CURB
CURB
CURB
CURB
CURB
26.500"W X 26.500"L X 20.000"H ALONG LENGTH, RIGHT VENTED HINGED.
26.500"W X 26.500"L X 20.000"H ALONG LENGTH, RIGHT VENTED HINGED.
23.000"W X 23.000"L X 20.000"H ALONG LENGTH, RIGHT VENTED HINGED.
19.500"W X 19.500"L X 12.000"H ALONG LENGTH, RIGHT.
19.500"W X 19.500"L X 12.000"H ALONG LENGTH, RIGHT.
NO
ON
FAN
WEIGHT ITEM SIZE
- VARIABLE SPEED CONTROL.
- THERMAL OVERLOAD PROTECTION (SINGLE PHASE).
- HIGH HEAT OPERATION 300°F (149°C).
EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING AIR AT 300°F (149°C)
UNTIL ALL FAN PARTS HAVE REACHED
THERMAL EQUILIBRIUM, AND WITHOUT ANY
DETERIORATING EFFECTS TO THE FAN WHICH
WOULD CAUSE UNSAFE OPERATION.
NORMAL TEMPERATURE TEST
26"
28"
37 3/8"
16 1/2"
2"
22 5/8"
- INTERNAL WIRING.
- ROOF MOUNTED FANS.
- RESTAURANT MODEL.
FEATURES:
- DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS).
TOP VIEW
37 3/8"
28"
- NEMA 3R SAFETY DISCONNECT SWITCH.
33 3/4"
GREASE DRAIN.
- GREASE CLASSIFICATION TESTING.
- UL705 AND UL762 AND ULC-S645
ABNORMAL FLARE-UP TEST
EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING BURNING GREASE VAPORS
AT 600°F (316°C) FOR A PERIOD OF
15 MINUTES WITHOUT THE FAN BECOMING
DAMAGED TO ANY EXTENT THAT COULD CAUSE
AN UNSAFE CONDITION.
26"
26"
ROOF OPENING
DIMENSIONS.
20"
26 1/2"
20 GAUGE
CONSTRUCTION.
STEEL
3" FLANGE.
26 1/2"
HINGE KIT
VENTED
CURB.
FANS #1, #2 - DU180HFA EXHAUST FAN
OPTIONS
- GREASE BOX.
- FAN BASE CERAMIC SEAL - INSTALLED
AT PLANT - FOR GREASE DUCTS.
- 2 YEAR PARTS WARRANTY.
OPEN POSITION
3 3/4
17 1/8
5 1/16
GREASE
BOX.
3 APPROX.
GREASE BOX INSTALLATION
COVER.
BOX
GREASE
GREASE
PIPE.
CURB.
(OPTIONAL).
KIT
HINGE
FAN.
CLOSED POSITION
INSTALL GREASE PIPE AS SHOWN ON PIC. 4.
GREASE PIPE.
GREASE BOX.
STEP 3)
PIC. 3
PIC. 4
COVER.
GREASE
BOX
HOLD 3" DIMENSION AS SHOWN ON PIC. 1.
SCREW GREASE BOX COVER TO CURB USING (3) LONG (3/4" LG.)
ATTACH GREASE BOX COVER TO THE CURB,
GREASE BOX FIELD INSTALLATION
ATTACH GREASE BOX TO GREASE BOX COVER, SLIDE AND DROP.
COVER.
BOX
GREASE
PIC. 1
COVER.
GREASE
BOX
3
AS SHOWN ON PIC. 3.
STEP 2)
CURB.
SCREWS AS SHOWN ON PIC. 2.
PARTS INCLUDED
GREASE BOX.
GREASE PIPE.
GREASE BOX COVER.
SHEET METAL SCREWS
3 - LONG (3/4" LG.).
STEP 1)
CURB.
PIC. 2
CURB.
08/19/02
GREASEBOX
REV.#2
*NOTE: UL 705 INSTALL.
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
e
c
o
n
a
i
r
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NFP
A
WIT
H
IN
S
LI
D
TE
R
C
U
S
MASTER DRAWING
3/4" = 1'-0"
6037327
6
JG
6/6/2023
Ea
s
t
e
r
n
L
A
&
O
r
a
n
g
e
C
t
y
M
e
c
h
30
0
2
D
o
w
A
v
e
n
u
e
,
S
u
i
t
e
2
0
2
,
T
u
s
t
i
n
,
C
A
,
9
2
7
8
0
P
H
O
N
E
:
(
7
1
4
)
5
0
3
-
0
7
7
7
E
M
A
I
L
:
r
e
g
1
4
4
@
e
c
o
n
a
i
r
.
c
o
m
Ta
i
e
r
R
e
s
t
a
u
r
a
n
t
-
A
r
c
a
d
i
a
Ar
c
a
d
i
a
,
C
A
,
9
1
0
0
7
40
0
S
o
u
t
h
B
a
l
d
w
i
n
A
v
e
n
u
e
,
S
u
i
t
e
2
3
1
- VARIABLE SPEED CONTROL.
- THERMAL OVERLOAD PROTECTION (SINGLE PHASE).
- HIGH HEAT OPERATION 300°F (149°C).
EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING AIR AT 300°F (149°C)
UNTIL ALL FAN PARTS HAVE REACHED
THERMAL EQUILIBRIUM, AND WITHOUT ANY
DETERIORATING EFFECTS TO THE FAN WHICH
WOULD CAUSE UNSAFE OPERATION.
NORMAL TEMPERATURE TEST
22 1/2"
24 3/4"
31 7/8"
14 7/8"
2"
23"
- INTERNAL WIRING.
- ROOF MOUNTED FANS.
- RESTAURANT MODEL.
FEATURES:
- DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS).
TOP VIEW
31 7/8"
24 3/4"
- NEMA 3R SAFETY DISCONNECT SWITCH.
30 1/2"
GREASE DRAIN.
- GREASE CLASSIFICATION TESTING.
- UL705 AND UL762 AND ULC-S645
ABNORMAL FLARE-UP TEST
EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING BURNING GREASE VAPORS
AT 600°F (316°C) FOR A PERIOD OF
15 MINUTES WITHOUT THE FAN BECOMING
DAMAGED TO ANY EXTENT THAT COULD CAUSE
AN UNSAFE CONDITION.
22 1/2"
22 1/2"
ROOF OPENING
DIMENSIONS.
20"
23"
20 GAUGE
CONSTRUCTION.
STEEL
3" FLANGE.
23"
HINGE KIT
VENTED
CURB.
FAN #3 DU85HFA - EXHAUST FAN
OPTIONS
- GREASE BOX.
- FAN BASE CERAMIC SEAL - INSTALLED
AT PLANT - FOR GREASE DUCTS.
- ECM WIRING PACKAGE - PWM SIGNAL
FROM ECPMO3 PREWIRE (TELCO MOTOR),
CCW ROTATION.
- 2 YEAR PARTS WARRANTY.
- THERMAL OVERLOAD PROTECTION (SINGLE PHASE).
16"
21"
25 1/2"
2"
12 1/8"
18 1/2"
FEATURES:
- INTERNAL WIRING.
- VARIABLE SPEED CONTROL.
- ROOF MOUNTED FANS.
- UL705.
- DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS).
TOP VIEW
25 1/2"
21"
- NEMA 3R SAFETY DISCONNECT SWITCH.
25 1/4"
3" FLANGE.
16"
16"
ROOF OPENING
DIMENSIONS.
20 GAUGE
CONSTRUCTION.
STEEL
12"
19 1/2"
19 1/2"
CURB.
(ROOF OPENING).
16
BACKDRAFT DAMPER INSTALLATION
BACKDRAFT DAMPER.
AIR FLOW
FANS #4, #5 - DU33HFA EXHAUST FAN
OPTIONS
- ECM WIRING PACKAGE - MANUAL OR
0-10VDC REFERENCE SPEED CONTROL
-RTC- (TELCO MOTOR), CCW ROTATION.
- I 15-BDD DAMPER.
- 2 YEAR PARTS WARRANTY.
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
e
c
o
n
a
i
r
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NFP
A
WIT
H
IN
S
LI
D
TE
R
C
U
S
MASTER DRAWING
3/4" = 1'-0"
6037327
7
JG
6/6/2023
Ea
s
t
e
r
n
L
A
&
O
r
a
n
g
e
C
t
y
M
e
c
h
30
0
2
D
o
w
A
v
e
n
u
e
,
S
u
i
t
e
2
0
2
,
T
u
s
t
i
n
,
C
A
,
9
2
7
8
0
P
H
O
N
E
:
(
7
1
4
)
5
0
3
-
0
7
7
7
E
M
A
I
L
:
r
e
g
1
4
4
@
e
c
o
n
a
i
r
.
c
o
m
Ta
i
e
r
R
e
s
t
a
u
r
a
n
t
-
A
r
c
a
d
i
a
Ar
c
a
d
i
a
,
C
A
,
9
1
0
0
7
40
0
S
o
u
t
h
B
a
l
d
w
i
n
A
v
e
n
u
e
,
S
u
i
t
e
2
3
1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Label Description Location
MT-01 Fan Motor [3]
SW-01 Main disconnect switch [3]
Component Identification
23
Installed Options
RD - RED
BL - BLUE
WH - WHITE
OR - ORANGE
BR - BROWN
BK - BLACK
PK - PINK
PR - PURPLE
GY - GRAY
GR - GREEN
YW - YELLOW
WIRE COLOR
DENOTES FIELD WIRING
DENOTES INTERNAL WIRING
NOTES
SW-01
BK
BK
MT-01
GR
BK
GR
BK
BK
BK
5 6
3 4
1 2
GR
EXHAUST 3HP-208V-3P-9.4FLA
VFD PART: ESV222N02YXB571
MOTOR INFO
ELECTRICAL INFORMATION
MOTOR/CTRL MCA: 11.8A
MOTOR/CTRL MOP: 20A
DRAWING NUMBER
JOB
MODELSHIP DATE
Exhaust Fan Wiring
EXH6037327-1
6037327 - Taier Restaurant - Arcadia
6/6/2023 DU180HFA
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Label Description Location
MT-01 Fan Motor [3]
SW-01 Main disconnect switch [3]
Component Identification
23
Installed Options
RD - RED
BL - BLUE
WH - WHITE
OR - ORANGE
BR - BROWN
BK - BLACK
PK - PINK
PR - PURPLE
GY - GRAY
GR - GREEN
YW - YELLOW
WIRE COLOR
DENOTES FIELD WIRING
DENOTES INTERNAL WIRING
NOTES
SW-01
BK
BK
MT-01
GR
BK
GR
BK
BK
BK
5 6
3 4
1 2
GR
EXHAUST 3HP-208V-3P-9.4FLA
VFD PART: ESV222N02YXB571
MOTOR INFO
ELECTRICAL INFORMATION
MOTOR/CTRL MCA: 11.8A
MOTOR/CTRL MOP: 20A
DRAWING NUMBER
JOB
MODELSHIP DATE
Exhaust Fan Wiring
EXH6037327-2
6037327 - Taier Restaurant - Arcadia
6/6/2023 DU180HFA
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Label Description Location
MT-01 Fan Motor [3]
SW-01 Main disconnect switch [3]
Component Identification
23
Installed Options
RD - RED
BL - BLUE
WH - WHITE
OR - ORANGE
BR - BROWN
BK - BLACK
PK - PINK
PR - PURPLE
GY - GRAY
GR - GREEN
YW - YELLOW
WIRE COLOR
DENOTES FIELD WIRING
DENOTES INTERNAL WIRING
NOTES
SW-01
BK
MT-01
GR
WH
GR
WH
BK
3 4
1 2
WH
*22 AWG WHITE MOTOR
*22 AWG
ROTATION WIRE. CONNECT TO 16 AWG
MOTOR
CONTROL
RD
YW
PWM
FROM
ECPMO3
RD
BK
16 AWG
16 AWG
BLACK WIRE TO REVERSE ROTATION
GR
EXHAUST 0.75HP-115V-1P-8.9FLA
MOTOR INFO
ELECTRICAL INFORMATION
MOTOR/CTRL MCA: 11.2A
MOTOR/CTRL MOP: 20A
DRAWING NUMBER
JOB
MODELSHIP DATE
Exhaust Fan Wiring
EXH6037327-3
6037327 - Taier Restaurant - Arcadia
6/6/2023 DU85HFA
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Label Description Location
MT-01 Fan Motor [3]
SW-01 Main disconnect switch [3]
Component Identification
23
Installed Options
RD - RED
BL - BLUE
WH - WHITE
OR - ORANGE
BR - BROWN
BK - BLACK
PK - PINK
PR - PURPLE
GY - GRAY
GR - GREEN
YW - YELLOW
WIRE COLOR
DENOTES FIELD WIRING
DENOTES INTERNAL WIRING
NOTES
24VAC 20VA Transformer
RTC-FSC-1
TR-01
SC-01
[2]
[1]
SW-01
BK
MT-01
GR
WH
GR
WH
BK
3 4
1 2
WH
*22 AWG WHITE MOTOR
16 AWG
*22 AWG
ROTATION WIRE. CONNECT TO 16 AWG
16 AWG
BLACK WIRE TO REVERSE ROTATION
GR
SC-01
TR-01
24V
BK
RD
WH
BK
0-10V
GND
CONTROL
MOTOR
24 VAC
RD
BK
P3
OPTIONAL 0-10VDC
SPEED REFERENCE
INPUT
EXHAUST 0.333HP-115V-1P-4.3FLA
MOTOR INFO
ELECTRICAL INFORMATION
MOTOR/CTRL MCA: 5.4A
MOTOR/CTRL MOP: 15A
DRAWING NUMBER
JOB
MODELSHIP DATE
Exhaust Fan Wiring
EXH6037327-4
6037327 - Taier Restaurant - Arcadia
6/6/2023 DU33HFA
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Label Description Location
MT-01 Fan Motor [3]
SW-01 Main disconnect switch [3]
Component Identification
23
Installed Options
RD - RED
BL - BLUE
WH - WHITE
OR - ORANGE
BR - BROWN
BK - BLACK
PK - PINK
PR - PURPLE
GY - GRAY
GR - GREEN
YW - YELLOW
WIRE COLOR
DENOTES FIELD WIRING
DENOTES INTERNAL WIRING
NOTES
24VAC 20VA Transformer
RTC-FSC-1
TR-01
SC-01
[2]
[1]
SW-01
BK
MT-01
GR
WH
GR
WH
BK
3 4
1 2
WH
*22 AWG WHITE MOTOR
16 AWG
*22 AWG
ROTATION WIRE. CONNECT TO 16 AWG
16 AWG
BLACK WIRE TO REVERSE ROTATION
GR
SC-01
TR-01
24V
BK
RD
WH
BK
0-10V
GND
CONTROL
MOTOR
24 VAC
RD
BK
P3
OPTIONAL 0-10VDC
SPEED REFERENCE
INPUT
EXHAUST 0.333HP-115V-1P-4.3FLA
MOTOR INFO
ELECTRICAL INFORMATION
MOTOR/CTRL MCA: 5.4A
MOTOR/CTRL MOP: 15A
DRAWING NUMBER
JOB
MODELSHIP DATE
Exhaust Fan Wiring
EXH6037327-5
6037327 - Taier Restaurant - Arcadia
6/6/2023 DU33HFA
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
e
c
o
n
a
i
r
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NFP
A
WIT
H
IN
S
LI
D
TE
R
C
U
S
MASTER DRAWING
3/4" = 1'-0"
6037327
8
JG
6/6/2023
Ea
s
t
e
r
n
L
A
&
O
r
a
n
g
e
C
t
y
M
e
c
h
30
0
2
D
o
w
A
v
e
n
u
e
,
S
u
i
t
e
2
0
2
,
T
u
s
t
i
n
,
C
A
,
9
2
7
8
0
P
H
O
N
E
:
(
7
1
4
)
5
0
3
-
0
7
7
7
E
M
A
I
L
:
r
e
g
1
4
4
@
e
c
o
n
a
i
r
.
c
o
m
Ta
i
e
r
R
e
s
t
a
u
r
a
n
t
-
A
r
c
a
d
i
a
Ar
c
a
d
i
a
,
C
A
,
9
1
0
0
7
40
0
S
o
u
t
h
B
a
l
d
w
i
n
A
v
e
n
u
e
,
S
u
i
t
e
2
3
1
ELECTRICAL PACKAGE - JOB#6037327
1
2
SC-E200111MA
SC-E100111MA
UTILITY CABINET LEFT
UTILITY CABINET LEFT
UTILITY CABINET
LEFT
HOOD # 1
UTILITY CABINET
LEFT
HOOD # 3
1 LIGHT
1 FAN
1 LIGHT
1 FAN
SMART CONTROLS THERMOSTATIC CONTROL
W/ RELAY ON/OFF WITH SUPPLY
SMART CONTROLS THERMOSTATIC CONTROL
W/ RELAY ON/OFF WITH SUPPLY
EXHAUST
EXHAUST
SUPPLY
EXHAUST
SUPPLY
3
3
1
1
1
3.000
3.000
1.000
0.750
0.333
208
208
115
115
115
9.4
9.4
12.6
8.9
5.8
NO TAG PACKAGE #LOCATION
SWITCHES
LOCATION QUANTITY
OPTION
FANS CONTROLLED
TYPE ɸ HP VOLT FLA
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
JOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
6037327
Taier Restaurant - Arcadia
SC-E200111MA
6/6/2023
INSTALL
ECP #1-1
Mixed Voltage w/ control for 2 3Ph Exhaust Fans, 1 120V 1Ph Supply Fan, Exhaust on in Fire, Relay On/Off with
Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation.
INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD.
BREAKER PANEL TO PRIMARY CONTROL PANEL
Responsibility: Electrician
BREAKER PANEL PRIMARY CONTROL PANEL
BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED
BREAKER 1PH
CONTROL POWER. DO NOT WIRE
TO GFCI OR SHUNT TRIP
BREAKER.
Hot
Neutral
H1
N1
120 V
15 A
Ground
GND
1ST HOOD LIGHT BREAKER SHARED W/
CONTROL POWER. SWITCH #1
WIRE TO VFD QUICK CONNECTOR
BREAKER 3PH
MCA:
MOCP:
LINE
LINE
Ground
EXH-1 SM-1
GND
L1
L2
LINE
L3
208 V
11.8 A
20 A
WIRE TO VFD QUICK CONNECTOR
BREAKER 3PH
MCA:
MOCP:
LINE
LINE
Ground
EXH-2 SM-2
GND
L4
L5
LINE
L6
208 V
11.8 A
20 A
BREAKER 1PH
MCA:
MOCP:
Hot
Neutral
L7
FN7
GND
Ground
SUP-6
115 V
15.8 A
25 A
CONTROL PANEL TO FANS
Responsibility: Electrician
PRIMARY PANEL FANS
Load Wiring
WIRE TO
VFD QUICK
WIRE TO
DISCONNECT
CONNECTOR
MUST HAVE ITS OWN CONDUIT
DO NOT SHARE CONDUIT!
FLA:
HP:
VOLT:
EXH-101
LOAD LEG 1
LOAD LEG 2
GND
GROUND
FAN:
SM-1
LOAD LEG 3
U1
V1
W1
9.4
3.000
208 V
Load Wiring
WIRE TO
VFD QUICK
WIRE TO
DISCONNECT
CONNECTOR
MUST HAVE ITS OWN CONDUIT
DO NOT SHARE CONDUIT!
FLA:
HP:
VOLT:
EXH-202
LOAD LEG 1
LOAD LEG 2
GND
GROUND
FAN:
SM-2
LOAD LEG 3
U2
V2
W2
9.4
3.000
208 V
Load Wiring
WIRE DIRECT
TO STARTER
BLACK
WHITE
GREEN
WIRE TO FACTORY
PROVIDED CONDUIT DROP
FLA:
HP:
VOLT:
T1
T2
LEG 1 / HOT
LEG 2 / NEUTRAL
GND
GROUND
C-1
SUP-6
06FAN:
12.6
1.000
115 V
CONTROL PANEL TO ACCESSORY ITEMS
Responsibility: Electrician
CONTROL PANEL COMPONENT
ALL SWITCHES FACTORY WIRED
CAT-5 CONNECTION
CONTROL PANEL
SWITCHES
TO
J4
CONTROL PANEL
HOOD LIGHTS
TO
1400 W MAX
WIRE TO J-BOX ON TOP OF HOOD
B1
W1
GND
BLACK
WHITE
GREEN
HOOD LIGHTS 1
WIRE TO CONTROL BOARD. INSTALL
SENSOR IN ROOM AWAY FROM HEAT
SOURCES. DO NOT INSTALL SENSOR
CONTROL PANEL
KITCHEN TEMP
TO
SENSOR
ON THE CEILING GRID, SEE MANUAL.
T1A
T1B
ROOM TEMP
FACTORY WIRED TEMPERATURE
SENSOR. MOUNTED IN EXHAUST DUCT
CONTROL PANEL
DUCT SENSOR
TO
T2A
T2B
HOOD 1
RISER 1
WIRE TO CONTROL BOARD.
SENSOR MOUNTED IN EXHAUST DUCT
CONTROL PANEL
DUCT SENSOR
TO
T3A
T3B
HOOD 2
RISER 1
CONTROL PANEL
GAS VALVE
TO
120V ONLY
ONLY ENERGIZED THROUGH LCD
HMI WHEN FIRE SYSTEM ARMED.
GAS
N1
HOT TO GAS VALVE
NEUTRAL
GAS SOLENOID
THE FOLLOWING CONNECTIONS
MAY OR MAY NOT BE
REQUIRED BASED ON JOBSITE
SPECIFICATIONS
CONTROL PANEL
EXTERNAL
SIGNAL FOR
SHUNT TRIP
ST TERMINAL IS ENERGIZED
IN FIRE CONDITION.
CONTROL PANEL
EXTERNAL
SIGNAL FOR
CONTACTOR COIL
KS TERMINAL IS DE-ENERGIZED
IN FIRE CONDITION.
ST
N1
NEUTRAL FROM SHUNT COIL
HOT TO SHUNT COIL
SHUNT COIL
KS
N1
NEUTRAL_TO_CONTACTOR_COIL
HOT_TO_CONTACTOR_COIL
CONTACTOR_COIL
SPARE CONTACTS WILL MAKE
CONTROL PANEL
ON/OFF WITH
DRY CONTACT
SUPPLY FAN
COMMON TO NORMALLY OPEN
WHEN SUPPLY FAN IS ON.
GROUP 1
SFC1
SFO1
COMMON
NORMALLY OPEN
SFC2
SFO2
COMMON
NORMALLY OPEN
CONTROL PANEL
EXTERNAL
TO
SWITCH
SIGNAL SWITCH THROUGH BMS
WILL ACTIVATE ZONE1 FANS AND
LIGHTS
H1
IO1
BMS SWITCH
C NO
CONTROL PANEL
GAS VALVE
TO
24V DC ONLY
ONLY ENERGIZED THROUGH LCD
HMI WHEN FIRE SYSTEM ARMED.
(NOT NEEDED IF USING 120V
GAS VALVE).
LGV
N1D
POSITIVE TO GAS VALVE
NEGATIVE
GAS SOLENOID
CONTROL PANEL TO FIRE SYSTEM
Responsibility: ALARM CONTRACTOR
CONTROL PANEL COMPONENT
CONTROL PANEL
BUILDING
SIGNAL FOR
FIRE ALARM
PANEL
AL1
AL2
J9
BUILDING
ALARM PANEL
FIRE INPUT
WIRE DIRECTLY TO CORE CIRCUIT
BOARD. AL1 WILL MAKE AL2 IN FIRE
CONDITION.
CONTROL PANEL
BUILDING
SIGNAL FOR
TROUBLE
TROUBLE RELAY CONTACTS WILL
MAKE TBC TO TBL IN TROUBLE
CONDITION.
BUILDING
ALARM PANEL
ALARM
TBC
TBL
COMMON
NORMALLY CLOSED
CONTROL PANEL TO FIRE SYSTEM
Responsibility: CERTIFIED INSTALLER
CONTROL PANEL COMPONENT
21
22
FS-01
BK WH
Fire Stat
CONTROL PANEL
MOUNTED FIRE
TO DUCT
DETECTION
STAT(S)
FIRE STAT SUPERVISED LOOP
May be mixed factory and field
wiring. See Installation Schematic.
Multiple fire sensors possible.
HIGH TEMP WIRE (842 F), PN:
SLPCON-xFT required for all
Supervised Loop wiring in contact
with a hood. All other wiring shall
be PN: 6320UL, Belden or similar.
23
24
FS-02
BK WH
Fire Stat
FIRE STATS
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
JOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
6037327
Taier Restaurant - Arcadia
SC-E200111MA
6/6/2023
INSTALL
ECP #1-2
Mixed Voltage w/ control for 2 3Ph Exhaust Fans, 1 120V 1Ph Supply Fan, Exhaust on in Fire, Relay On/Off with
Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation.
INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD.
CONTROL PANEL
SYSTEM PULL
TO FIRE
STATION
MANUAL ACTUATION LOOP / REMOTE FIRE
SYSTEM LOOP.
Multiple manual actuation possible.
Multiple manual actuation possible.
A Plug jumper with wires from pin1 to
pin4 and from pin2 to pin3 is mounted on
J10, remove the jumpers and
wire in the supervised actuation loop.
Microswitch MS-01 is optional for fire
system interlock.
Auxiliary Interlock (AUX-01):
Wire AU1 / AU2 of adjacent Master FS
panel(s) in each manual activation loop
for simultaneous activation. See Fire
system drawings for more information.
101
102
103
104
AUX-01
AU1 AU2
PULL STATION
MS-01
C NO
Micro SW
MAD-01
C NO
Manual
Actuation
Device
Adjacent
FS
Panel
WIRE DIRECTLY TO CONTROL BOARD
CAT-5 CONNECTIONCONTROL PANEL
REMOTE FS
TO
MASTER PANEL
EOL120A
CORE PCB
ECPM03
PLACE END OF LINE PLUG
IN EMPTY JACK. PN: EOL120A
ADDITIONAL DEVICES MAY BE INLINE.
UNLESS VFD, PCU, OR OTHER
COMPONENT IN SERIES.
J3 J5
J6
CONTROL PANEL
MASTER FS
TO
PANEL
WIRE TO LIKE TERMINALS IN ALL
CORE PANELS THAT MUST ACTIVATE
TOGETHER. SET MASTER & SLAVE
DIP SWITCHES PER FIRE SYSTEM
SHIELDED TWISTED PAIR
INTERLOCK NETWORK MASTER CORE
MANUAL.
CA
CB
CC
BLACK
RED
SHIELD
CA
CB
CC
WALL MOUNT UTILITY CABINET CAS ELECTRIC WET CHEMICAL
PROTECTION ELECTRICAL DETAIL
02/11/2021 Rev. 02
ELECTRICIAN:
1. WIRE MAIN CONTROL PANEL PER INCLUDED SCHEMATIC
2. WIRE ALL FANS PER INCLUDED SCHEMATIC
3. WIRE SHUNT TRIP BREAKER (OPTIONAL)
4. WIRE UDS APPLIANCE KILL SWITCH, IF EQUIPPED (OPTIONAL)
5. WIRE GAS VALVE
NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS
EXHAUST HOOD
36 INCHES CLEARANCE REQUIRED IN FRONT
OF ALL UTILITY CABINET DOORS
THE PANEL SHALL ALSO BE LOCATED IN AN
ACCESSIBLE AREA WHERE THE AUDIBLE AND
VISUAL ALARMS CAN BE HEARD AND SEEN
GAS
ELECTRIC
ELECTRICAL CONTRACTOR REQUIREMENT
ITEM CONNECTION IN PANEL CONNECTION IN DEVICE VOLTAGE AMPERAGE COMMENTS
SHUNT TRIP BREAKER (OPTIONAL)ST & N1
BREAKER COIL
(A1 & A2)
120 VAC < 4 AMPS ST TO A1 ON SHUNT BREAKER COIL, AND NEUTRAL TO A2 ON SHUNT TRIP BREAKER COIL
CONTROL PANEL POWER H1 & N1 + GROUND CIRCUIT BREAKER 120 VAC 15 AMPS CONTROL PANEL POWER MUST NOT BE RUN THROUGH SHUNT TRIP BREAKER
UDS APPLIANCE KILL SWITCH (OPTIONAL)KTS & N1 KTS & N1 120 VAC < 4 AMPS KILL SWITCH TERMINALS MUST BE IN SERIES WITH OTHER KILL SWITCHES
REMOTE 120VAC ANSUL AUTOMAN (OPTIONAL)AU1, AU2 SOLENOID 120 VAC < 6 AMPS 120V TO AU1, AU2 TO ANSUL ELECTRIC AUTOMAN, ANSUL SOLENOID TO NEUTRAL
GAS VALVE
LGV & N1D (IF 24 VDC)
GAS & N1 (IF 120 VAC)
RED/RED/GREEN
24 VDC
OR 120 VAC
< 1.0 AMPS
IF 24 VDC - 2 WIRES & GROUND, N1D TO RED, LGV TO RED, AND GREEN TO GROUND
IF 120 VAC - 2 WIRES & GROUND GAS TO RED, N1 TO RED, AND GREEN TO GROUND
SHUNT TRIP BREAKER (OPTIONAL)
-2 WIRES, 120VAC
-ST TO A1 ON SHUNT BREAKER
-NEUTRAL TO A2 ON SHUNT TRIP
BREAKER
POWER TO ELECTRIC
APPLIANCE
CONTROL PANEL POWER
-2 WIRES & GROUND
-120 VAC, 15 AMP SERVICE
-WIRE TO H1 AND N1, GROUND
-POWER MUST NOT ORIGINATE
FROM SHUNT TRIP BREAKER
GAS VALVE POWER
-2 WIRES & GROUND
-24 VDC WIRE TO LGV & N1D
-120 VAC WIRE TO GAS &N1
GAS VALVE
-STRAINER MUST BE
INSTALLED UPSTREAM
OF VALVE
COOKING
APPLIANCE(S)
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
JOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
6037327
Taier Restaurant - Arcadia
SC-E200111MA
6/6/2023
INSTALL
ECP #1-3
Fire System #1 TANK FS - 4.0/4.0/4.0/4.0.
FS-1: MASTER
WALL MOUNT UTILITY CABINET CAS ELECTRIC WET CHEMICAL
PROTECTION LOW-VOLTAGE DETAIL
02/05/2018 Rev. 1
ALARM CONTRACTOR:
1. WIRE MANUAL ACTUATION DEVICE(S), REMOTE FIRESTAT(S), CORE INTERLOCK(S), FIRE SENSOR(S) AND FIRE ALARM CONTACTS
2. COMPLETE FINAL HOOKUP OF SYSTEM
3. VERIFY FINAL FIRE SYSTEM TEST
ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD
BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES
36 INCHES CLEARANCE REQUIRED IN
FRONT OF ALL UTILITY CABINET DOORS
THE PANEL SHALL ALSO BE LOCATED IN
AN ACCESSIBLE AREA WHERE THE
AUDIBLE AND VISUAL ALARMS CAN BE
HEARD AND SEEN
EXHAUST HOOD
ELECTRIC GAS
NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS
ALARM CONTRACTOR REQUIREMENT
ITEM CONNECTION IN PANEL CONNECTION ON DEVICE VOLTAGE AMPERAGE COMMENTS
MANUAL ACTUATION DEVICE(S)
101 AND 104
102 AND 103
1 & 2 24 VDC < 1.0 AMPS
WIRE MANUAL ACTUATION DEVICE TERMINAL 1 BETWEEN CORE PANEL TERMINALS 102 AND 103
WIRE MANUAL ACTUATION DEVICE TERMINAL 2 BETWEEN CORE PANEL TERMINALS 101 AND 104
JUMPER 101 TO 104 AND 102 TO 103 IF NO MANUAL ACTUATION DEVICE IS INSTALLED
MANUAL ACTUATION DEVICE COVER N/A N/A N/A N/A
MANUAL ACTUATION DEVICE COVER MUST BE INSTALLED
IF SURFACE MOUNTED, USE COVER EXTENSION STI-6531B
REMOTE FIRESTAT SENSOR(S)
21 AND 24
22 AND 23
BLACK AND WHITE 24 VDC < 1.0 AMPS
WIRE FIRE SENSOR WHITE WIRES BETWEEN HOOD CORE PANEL TERMINALS 22 AND 23
WIRE FIRE SENSOR BLACK WIRE BETWEEN HOOD CORE PANEL TERMINALS 21 AND 24
HIGH TEMP (842°F) #CW04427 (WHT) & #CW04427B (BLK)WIRE OR SIMILAR ONLY IF RAN OVER TOP
OF HOOD; OTHERWISE BELDEN #6320UL OR SIMILAR PLENUM RATED WIRE; SEE FIGURE 1
FIRE ALARM CONTACT AL1, AL2 VARIES
50V MAX
(AC/DC)
UP TO 1 AMP
FIRE ALARM RELAY CONTACTS FOR BUILDING FIRE ALARM LOCATED IN THE
CORE ELECTRICAL CONTROL PANEL
CORE INTERLOCK(S)ILA, ILB, ILC ILA, ILB, ILC
RS-485 COMMUNICATIONS
SIGNAL
CORE SYSTEM (1) ILA, TO CORE SYSTEM (2) ILA. CORE SYSTEM (1) ILB, TO CORE SYSTEM (2) ILB.
CORE SYSTEM (1) ILC, TO CORE SYSTEM (2) ILC. USE BELDEN# 88760 OR SIMILAR WIRE
TROUBLE CONTACT TBC, TBL, TOK VARIES MAX 120 VAC
UP TO 6
AMPS
WIRE TO TBL & TBC NORMALLY OPEN CONTACT, CLOSES IN TROUBLE CONDITION
CORE COMMUNICATIONS CABLE RJ-45 Jack INTERNET CONNECTION SIGNAL <1.0 AMPS
TYPICAL CONNECTION CAT5 CABLE TO LOCAL AREA NETWORK VIA ETHERNET SWITCH OR
WIRELESS ROUTER WITH VALID INTERNET CONNECTION
42 TO 48 INCHES
ABOVE FLOOR
LEVEL TO
CENTER OF PUSH
STATION
MANUAL
ACTUATION
DEVICE
10 TO 20
FEET FROM
HOOD LOCATED
NEAR POINT
OF EGRESS
FROM HOOD
MANUAL ACTUATION DEVICE WIRES
-4 WIRES, 24VDC WIRE (TERMINAL 1)
BETWEEN 102 AND 103
-WIRE (TERMINAL 2) BETWEEN 101 AND 104
-ADDITIONAL PULL STATIONS WIRED IN
SUPERVISED LOOP
-USE BELDEN #6320UL OR SIMILAR WIRE
-SEE FIGURE 2
MANUAL ACTUATION DEVICE
PART #STI-SS2431
PROTECTIVE COVER MUST BE INSTALLED
SUPERVISED LOOP
-4 WIRES, 24VDC CONNECT BLACK
WIRES BETWEEN 21 AND 24 IN PANEL,
CONNECT WHITE (OR RED) WIRES
BETWEEN 22 AND 23 IN PANEL
-ADDITIONAL FIRESTATS, WIRED IN
SUPERVISED LOOP
-USE HIGH TEMP (842°F) #CW04427
(WHT) & #CW04227B (BLK)WIRE ONLY
IF RAN OVER TOP OF HOOD;
OTHERWISE BELDEN #6320UL OR
SIMILAR PLENUM RATED WIRE
-SEE FIGURE 1
CORE COMMUNICATIONS CABLE
-CAT5 CABLE
MUST BE INSTALLED TO A LOCAL AREA
NETWORK WITH VALID INTERNET ACCESS
VIA ETHERNET SWITCH OR WIRELESS
ROUTER
CORE INTERLOCK
-2 WIRES + SHIELD
-USE BELDEN#88760 OR SIMILAR WIRE
-SEE FIGURE 3
FIRE ALARM PANEL
FIRE ALARM CONTACT
-2 WIRES WIRED TO NORMALLY OPEN CONTACTS
(CLOSES IN FIRE CONDITION)
-CORE CONTROL PANEL AL1 AND AL2
-SEE FIGURE 2
TROUBLE CONTACT
-2 WIRES TO NORMALLY OPEN
CONTACTS (CLOSE IN TROUBLE
CONDITION)
-CORE PANEL TERMINALS TBL AND TBC
-SEE FIGURE 4
COOKING
APPLIANCE(S)
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
JOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
6037327
Taier Restaurant - Arcadia
SC-E200111MA
6/6/2023
INSTALL
ECP #1-4
Fire System #1 TANK FS - 4.0/4.0/4.0/4.0.
FS-1: MASTER
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
e
c
o
n
a
i
r
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NFP
A
WIT
H
IN
S
LI
D
TE
R
C
U
S
MASTER DRAWING
3/4" = 1'-0"
6037327
9
JG
6/6/2023
Ea
s
t
e
r
n
L
A
&
O
r
a
n
g
e
C
t
y
M
e
c
h
30
0
2
D
o
w
A
v
e
n
u
e
,
S
u
i
t
e
2
0
2
,
T
u
s
t
i
n
,
C
A
,
9
2
7
8
0
P
H
O
N
E
:
(
7
1
4
)
5
0
3
-
0
7
7
7
E
M
A
I
L
:
r
e
g
1
4
4
@
e
c
o
n
a
i
r
.
c
o
m
Ta
i
e
r
R
e
s
t
a
u
r
a
n
t
-
A
r
c
a
d
i
a
Ar
c
a
d
i
a
,
C
A
,
9
1
0
0
7
40
0
S
o
u
t
h
B
a
l
d
w
i
n
A
v
e
n
u
e
,
S
u
i
t
e
2
3
1
ROOM TEMPERATURE
Provides room override based on
temperature differential between the
room and duct. Installed by electrician
on a wall, 5'-6' off the finished floor, in
the space but not directly under the
hood or close to an appliance (including
the electrical control box) so the
reading is accurate for space.
FANSLIGHTS
SENSOR
DUCT TEMPERATURE
Provides exhaust air temperature for
proper hood control operation. For all
installations excluding a single hood with
factory risers and a hood mounted panel,
duct mounted temperature sensors will
need to be field wired. 2-wire 18 AWG
plenum rated thermistor cable must be
used.
SENSOR
HOOD CONTROL
The LCD interface provides user control
and hood status. The faceplate is
connected to the hood control panel
through CAT-5 cable. A faceplate has 2
RJ-45 connectors. One connects to port
J4 or J5 in the hood control panel and
the other will typically be occupied by a
RJ-45 end-of-line terminator.
INTERFACE
WALL MOUNTED CAS ELECTRIC WET CHEMICAL
02/05/2015 Rev. 16
AL1
AL2 END
OF
LINE
DEVICE
WIRING CONNECTIONS FOR FIRE
ALARM CONTACT
FIGURE 2
CORE
CONTROL
PANEL
FIRE
ALARM
CONTACT
ALARM
INPUT
BUILDING
FIRE ALARM
SHIELDED TWISTED PAIR
ILA
ILC
ILB
ILA
BK
ILB
RD
BK
RD
WIRING CONNECTIONS
FOR CORE INTERLOCK
FIGURE 3
ILC
ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD
BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES
SUPERVISION
SWITCH
1 2
C
BUILDING
FIRE ALARM
TROUBLE
INPUT
CORE
CONTROL
PANEL
TROUBLE CONTACT
NO
C
NC 1
C
2
SUPERVISION
SWITCH
SUPERVISION
SWITCH
END
OF
LINE
DEVICETBC
TBLTOK
WIRING CONNECTIONS FOR
TROUBLE CONTACT
FIGURE 4
BK-C
BK-C
21
22
23
24
J2-1
J2-2
J2-4
J2-3
21
BK-C
101
102
103
104
J10-1
J10-2
J10-4
J10-3
21
BK-C
WIRING CONNECTIONS
FOR FIRESTAT LOOP
FIGURE 1
WIRING CONNECTIONS
FOR MANUAL ACTUATION LOOP
FIGURE 1A
BREAK WIRE
BEFORE
INSERTING
INTO
TERMINALS
FIRE
STAT-2
FIRE
STAT-1 NO-WH
(OR RD)
NO-WH
(OR RD)
BREAK WIRE
BEFORE
INSERTING
INTO
TERMINALS
NO-WH
(OR RD)
MANUAL
ACTUATION
DEVICE
NO-WH
(OR RD)
MANUAL
ACTUATION
DEVICE
MICROSWITCH/
NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS
USE BELDEN #6320UL
OR SIMILAR WIRE
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
PROTECTION LOW-VOLTAGE FIGURES
FS-1: MASTER
WH
BK
A B C D E F G H I
1
2
3
4
5
6
7
8
9
10
FACTORY WIRING
SCHEMATIC
CIRCUIT BOARDS
MOTOR POWER CIRCUIT
PANEL LID
COMPONENT LIST
LABEL DESCRIPTION
ST-X
varies
Starter
OL-X
varies
Overload
C-X
varies
Contactor
TS-x
A/CP-PO-T4"-EXPL
Duct Thermostat
120 VAC
RELAY
NO
COM
COIL
NC
34
6 5
8
2
7
1
RA-x
24 VDC
RELAY
RD-x
NO
COM
COIL
NC
34
6 5
8
2
7
1
PS-1
MDP18-24A-1C
Power Sup. 24VDC
BK
RA-x
34.110.0184.0
120V Relay DPDT
WH
RA-x
34.110.0184.0
120V Relay DPDT
GR
UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG.
N1
H1
DC
-
GN
D
DC
+
8H1
7PCU
6ST
5KS
4KTS
3GAS
2AR1
1N1
120VJ9
5OV1
4SF1
3EF1
2B1
1IO1
120VJ7
AR1
H1
2x
N1
2x
B1
EF1
SF1
BK
IO1
N1
BK
BK
BK
JUMPER
W1
BK 14AWG BK
64
RD-1
BL PR
DC+RO1
RD-x
34.110.0188.0
24VDC Light Relay
BK WH
SF1 7 8RA-2
A1 A2C-1
8 7RD-1
24V
1 2 3 4 5 6 7
8 9 10 11121314
J6
N1
ON/OFF
WITH
SUP
N1
RO
1
NH
FAN
PANEL COOLING
DRY CONTACTS (SHOWN DE-ENERGIZED)
HOOD LIGHTS
J3
ECPM03/DAISY CHAIN
AR1 H1
JUMPER FIRE SYSTEM
BK
BK
BK
GAS
KS
ST
NOTE: Configure ECPM03 for CORE
SM-1 SM-2
ECPM03
J10
IL
1
A
IL
1
B
JUMPER
MAKE UP AIR INTERLOCK.
1
2
11
1
JUMPER
1
2
11
1
JUMPER
NOTE: All items on ECPM03 J3 line to be daisy chained
from one component to the next, with EOL120A at end
of line. Place PN: EOL120A in empty RJ45 port.
J3
ECPM03 or Previous EOL
J5
MASTER CORE
C
RA-2-1
NO
SFC1
SFO1
14 AWG
YW
C
RA-2-2
NO
SFC2
SFO2
14 AWG
YW
20 x 18 x 8.62 BOX
CONTROL INPUT 120V
H1=LINE, N1=NEUTRAL,
15A BREAKER. DO NOT
CONNECT TO SHUNT TRIP
BREAKER. SEE
INSTALLATION SCHEMATIC
FOR ADDITIONAL REQ.
LEGEND
FIELD WIRING
FACTORY WIRING
BK- BLACK
BL- BLUE
BR- BROWN
OR- ORANGE
WH- WHITE
OR/BL- OR/BL STRIPE
BL/RD- BL/RD STRIPE
RD/GN- RD/GN STRIPE
WH/BL- WH/BL STRIPE
YW- YELLOW
GY- GREY
PR- PURPLE
RD- RED
GR- GREEN
WH
/
B
L
BL
H1N1
DC
-
DC
+
LN
-+
PS-01
AC
24V
GN
D
DC
KSKS
BK
KS
BK
BK
GAS
ST
BK
EF1
PR
WH
GR
/
Y
W
WH
/
B
L
BL
J4 J5
NH
FAN
SECONDARY PANEL COOLING IF NECESSARY
EF1
WHBK
JUMPER
ECPM03
J10
IL
2
A
IL
2
B
TERMINAL GAS USED FOR
120V POWERED GAS
VALVES ONLY
DWG NO
JOB NO
DATE
DRAWN BY
JOB NAME
DESCRIPTION OF OPERATION
TYPE
DRAWING TITLE
6037327
Taier Restaurant...
FACTORY
SC-E200111MA
6/6/2023
ECP #1-6
Mixed Voltage w/ control
for 2 3Ph Exhaust
Fans, 1 120V 1Ph Supply
Fan, Exhaust on in Fire,
Relay On/Off with Supply
Fan, Fan(s) On/Off
Thermostatically
Controlled. Room
temperature sensor
shipped loose for field
installation. INVERTER
DUTY 3 PHASE MOTOR
REQUIRED FOR USE WITH
VFD.
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
U/T1
V/T2
W/T3
L1
L2
L3/N
GR
GR
GND
VFD:
HP:
MTR:
FLA:
P107:
P108:
P410:
P150:
P100:
P194:
P101:
P131:
P167:
P103:
P102:
L1
L2
L3
14 AWG
3 PH
20 A
208 V
U1
V1
W1
SM-1
ESV222N02YXB571
225
01
01
11
97
00
9.4
3.000
EXH-1
N/A
N/A
52.4
49.0
0.0
GND
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
U/T1
V/T2
W/T3
L1
L2
L3/N
GR
GR
GND
VFD:
HP:
MTR:
FLA:
P107:
P108:
P410:
P150:
P100:
P194:
P101:
P131:
P167:
P103:
P102:
L4
L5
L6
14 AWG
3 PH
20 A
208 V
U2
V2
W2
SM-2
ESV222N02YXB571
225
01
01
12
97
00
9.4
3.000
EXH-2
N/A
N/A
52.4
49.0
0.0
GND
BK
WH
T1
T2
T3
L1
L2
L3
1413
CONT:
FLA:
MTR:
HP:
L7
FN7
C-112 AWG
1 PH
25 A
115 V
SUP-6
100-C16D10
12.6
1.000
A B C D E F G H I
1
2
3
4
5
6
7
8
9
10
FACTORY WIRING
SCHEMATIC
CORE FIRE
PROTECTION
COMPONENT LIST
LABEL DESCRIPTION
120 VAC
RELAY
NO
COM
COIL
NC
34
6 5
8
2
7
1
RA-x
24 VDC
RELAY
RD-x
NO
COM
COIL
NC
34
6 5
8
2
7
1
24 VOLT BATTERY PACK
5 AMP FUSE
RD
SHIELDED TWISTED PAIR
PCB-2
J3-2
J4-1
J3-11
J4-3
J4-2
J4-8
J4-9
J4-12
J3-14
J4-5
J3-13
J3-4
J4-6
J3-10
J2-1
J2-2
J2-3
J2-4
J7-2
J7-3
J7-1
J3-1 J3-3
RD
RD BR
RD
ALL 18AWG
RD BK
ORRD
PKRD
BRRD
RD OR/BL
BK 18AWG
BK
BK
J3-5
J1-1
J1-2
RD
BK
BK
RD
FIRE STAT SUPERVISED LOOP
May be mixed factory and field
wiring. See Installation Schematic.
Multiple fire sensors possible.
+
+
RD
BK
BK
RD
Shield
BK
RD
RS-485 CORE INTERLOCK
NETWORK. Connection to
other CORE Panels or
Communication Module. See
Installation Schematic for
Connection.
N1D 3xH1D3x
DISCONNECT J1
21
22
23
24
16AWG
WH
N1
H1
PN: 1606-XLP-60EQ
Adjust power supply to 27.5
Volts with an accurate
Digital Volt Meter or with an
HMI plugged into the CORE
board.
NL
+-
PSM-2 60W
GR
BK
GND
PCB-2
PCBCORE-APP
CORE PCB
PSM-2
1606-XLP-50E
CORE POWER SUPPLY
WS-x
varies
Water Solenoid
LT-06
PNL-1163-0UR
24V Red Ind. Light
LL-01
AQ5510
Surf. Level Sensor
AA-01
SCE120LA3FP1B
Audible Alarm
PB-01
D7-F2X11
Prime/Reset Switch
SW-04
BZ-2RQ1-A2
Tamper Switch
SP-1
50000-805
Surfactant Pump
PB-01
Prime / Reset
A2A1
RD-20
Trouble Relay
A2A1
RD-17
Fire Relay
DRY CONTACTS (SHOWN DE-ENGERGIZED)
AA-01
Audible Alarm
SW-04
Door Tamper Switch
C NO
FS-01
BK WH
Fire Stat
FS-02
BK WH
Fire Stat
HIGH TEMP WIRE (842 F),
PN: SLPCON-xFT required
for all Supervised Loop
wiring in contact with a
hood. All other wiring
shall be PN: 6320UL,
Belden or similar. Factory
mounted hood sensors will
be terminated at junction
box on top of hood.
GV-1
varies
24v DC Gas Valve
INTERLOCK FOR AUTOMAN ACTIVATION.
Used for activating 120V automan
or adjacent Master CORE panels
during active Fire Condition.11
RD-18-1
14
YW
J3-16
J3-8
BR
38
LT-6
R
FIRE INDICATOR
DIP Switch
ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD
BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES.
RD/GNRD
A2A1
RD-19
Equipment Relay COOKING EQUIPMENT DISABLE RELAY.
For UDS Kill Switch, wire EKC and
EKS terminals to like terminals in
UDS panel.
12
11
RD-19-1
14
EKC
EST
EKS
YW
INTERLOCK FOR AUTOMAN ACTIVATION.
Used for activating 120V automan
or adjacent Master CORE panels
during active Fire Condition.11
RD-18-1
14
YW
RD OR/BL
A2A1
RD-18
Auxiliary Interlock Relay
FS-XX
12-F28021-000360
Duct Fire Sensor
LT-05
PNL-1163-0UY
24V YLW Ind. Light
PS-01
Station STI-SS2431
Remote Puill/Push
FOR SHIPMENT
J10-1
J10-2
J10-3
J10-4
RD
BK
BK
RD
101
102
103
104
MANUAL ACTUATION LOOP / REMOTE FIRE
SYSTEM LOOP.
Multiple manual actuation possible.
A Plug jumper with wires from pin1 to
pin4 and from pin2 to pin3 should be
mounted on J10 if there is no manual
actuation device and no microswitch.
Jumper if water valve
supervision switch is used
MAD-01
C NO
Manual
Actuation
Device
MS-01
C NO
Micro SW
1 2 3 4 5 6 7 8
SW
1
OPEN
PUT END OF LINE PLUG IN EMPTY RJ45
J3
ECPM03
UNLESS PCU AFM OR OTHER COMPONENT IN SERIES.
CAT-5 WIRING (MASTER ONLY)
FIELD WIRED IF REMOTE PREWIRE
RD-XX
PLC-RPT-24DC/21
24VDC Phoenix Relay
AUX-01
AU1 AU2
Auxiliary Interlock (AUX-01):
Wire AU1 / AU2 of adjacent Master CORE
panel(s) in each manual activation loop
for simultaneous activation.
AU1/AU2 will have continuity for 10
seconds if adjacent panel goes into fire
condition, activating this CORE Panel but
allowing for a reset after 10 seconds.
NOTE: AU1/AU2 terminals of CORE Panel
should not be wired into its own manual
activation loop.
Adjacent
CORE
Panel
Master CORE
set DIP SW 8
to CLOSED
position. Slave
CORE with
address 1 set
DIP SW 8 to
CLOSED
position. All
other CORES
set DIP SW 8
OPEN.
18AWG
LEGEND
FIELD WIRING
FACTORY WIRING
BK- BLACK
BL- BLUE
BR- BROWN
OR- ORANGE
WH- WHITE
OR/BL- OR/BL STRIPE
BL/RD- BL/RD STRIPE
RD/GN- RD/GN STRIPE
WH/BL- WH/BL STRIPE
YW- YELLOW
GY- GREY
PR- PURPLE
RD- RED
GR- GREEN
FIRE INDICATOR FAULT CONDITION FLASH CODES
2 Release Solenoid
3 Pressure Switch
4 Auxiliary Fault
5 Microcontroller Fault
6 N/A
7 Supervised Loop
8 Ground Fault
9 Surfactant Low
10 Battery Voltage Low
11 AC Power Failure
12 Door Tamper Switch
13 Test Mode
14 CORE Interlock Network
15 Fault on Hood in Interlock Network
16 Fault on PCU in Interlock Network
FIRE ALARM SYSTEM DRY CONTACTS.
Termials AL1 & AL2 make in FIRE.
To Building Fire
Alarm Panel
J9
AL1
AL2
J3-7
FIRE SYSTEM DRY CONTACTS.
Dry contacts will make C2 to AR2
when system is armed.
12
11
RD-17-1
C2
AR2
14 AWG
YW
TROUBLE RELAY. Contact terminals
TBC & TBL make if there is trouble.
Contact terminals TBC & TOK make if
the system is ok.
12
11
RD-20-1
14
TBC
TBL
TOK
YW
RD
PS
OR
J4-9
PS
EWC-PRESSURE
Pressure Switch
PR
RS
SW-05-1
Test Armed
3 4 YW
RS-1
RELEASE SOLENOID
BLBR
RD OR
SW-05-2
Test Armed
3 4 J4-13
SW-05
ZB5AD2
TEST/ARM Switch
RS2
PR
SW-05-1
Test Armed
3 4
YW
PS-1
Pressure Switch
WH
14
PWS-01
24VDC 18W POWER
24VDC Power Suppl
CA
CB
CC
AU1AU1
AU2AU2
TR2
MAD-01
DEVICE
MANUAL ACTIVATION
GAS VALVES SHOULD BE WIRED
TO MASTER CORE BOARD ONLY.
RDRD
GV-1
24V DC Gas Valve
LGV
PK TERMINAL LGV USED FOR 24VDC
POWERED GAS VALVES ONLY.
DWG NO
JOB NO
DATE
DRAWN BY
JOB NAME
DESCRIPTION OF OPERATION
TYPE
DRAWING TITLE
6037327
Taier Restaurant...
FACTORY
SC-E200111MA
6/6/2023
ECP #1-7
Fire System #1 TANK FS
- 4.0/4.0/4.0/4.0.
FS-1: MASTER
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
JOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
6037327
Taier Restaurant - Arcadia
SC-E100111MA
6/6/2023
INSTALL
ECP #2-1
Mixed Voltage w/ control for 1 3Ph Exhaust Fan, 1 120V 1Ph Supply Fan, Exhaust on in Fire, Lights out in Fire,
Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for
field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD.
BREAKER PANEL TO PRIMARY CONTROL PANEL
Responsibility: Electrician
BREAKER PANEL PRIMARY CONTROL PANEL
BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED
BREAKER 1PH
CONTROL POWER. DO NOT WIRE
TO GFCI OR SHUNT TRIP
BREAKER.
Hot
Neutral
H1
N1
120 V
15 A
Ground
GND
1ST HOOD LIGHT BREAKER SHARED W/
CONTROL POWER. SWITCH #1
BREAKER 1PH
MCA:
MOCP:
Hot
Neutral
L1
FN1
GND
Ground
SUP-7
115 V
7.2 A
15 A
BREAKER PANEL TO FANS
Responsibility: Electrician
BREAKER PANEL FANS
BREAKER 1PH
MCA:
MOCP:
POWER TO
ECM FANS
HOT
NEUTRAL
115V
11.1A
EXH-3
Ground
20A
CONTROL PANEL TO FANS
Responsibility: Electrician
PRIMARY PANEL FANS
SHIELDED TWISTED PAIR
PWM
SPEED SIGNAL
CONTROL
PANEL TO
ECM
OUTDOOR RATED
FEED STP THROUGH INNER
COOLING TUBE. ALLOW FOR
ENOUGH SLACK ON STP FOR
PROPER HINGING. (EXHAUST ONLY)
NOTE: PWM SIGNAL IS POLARITY
SENSITIVE.
NIDEC MOTOR
TELCO MOTOR
BK TO GR
BK TO YW
RD TO RD
ZIEHL MOTOR
BK TO BK
P1A
P1B
EXH-3
ECM-01
FAN: 03
RED(+)
BLACK(-)
ECM-01
RED(+)
BLACK(-)
Load Wiring
WIRE DIRECT
TO STARTER
BLACK
WHITE
GREEN
WIRE TO FACTORY
PROVIDED CONDUIT DROP
FLA:
HP:
VOLT:
T1
T2
LEG 1 / HOT
LEG 2 / NEUTRAL
GND
GROUND
C-1
SUP-7
07FAN:
5.8
0.333
115 V
CONTROL PANEL TO ACCESSORY ITEMS
Responsibility: Electrician
CONTROL PANEL COMPONENT
ALL SWITCHES FACTORY WIRED
CAT-5 CONNECTION
CONTROL PANEL
SWITCHES
TO
J4
CONTROL PANEL
HOOD LIGHTS
TO
1400 W MAX
WIRE TO J-BOX ON TOP OF HOOD
B1
W1
GND
BLACK
WHITE
GREEN
HOOD LIGHTS 1
WIRE TO CONTROL BOARD. INSTALL
SENSOR IN ROOM AWAY FROM HEAT
SOURCES. DO NOT INSTALL SENSOR
CONTROL PANEL
KITCHEN TEMP
TO
SENSOR
ON THE CEILING GRID, SEE MANUAL.
T1A
T1B
ROOM TEMP
FACTORY WIRED TEMPERATURE
SENSOR. MOUNTED IN EXHAUST DUCT
CONTROL PANEL
DUCT SENSOR
TO
T2A
T2B HOOD 3
RISER 1
CONTROL PANEL
GAS VALVE
TO
120V ONLY
ONLY ENERGIZED THROUGH LCD
HMI WHEN FIRE SYSTEM ARMED.
GAS
N1
HOT TO GAS VALVE
NEUTRAL
GAS SOLENOID
THE FOLLOWING CONNECTIONS
MAY OR MAY NOT BE
REQUIRED BASED ON JOBSITE
SPECIFICATIONS
CONTROL PANEL
EXTERNAL
SIGNAL FOR
SHUNT TRIP
ST TERMINAL IS ENERGIZED
IN FIRE CONDITION.
CONTROL PANEL
EXTERNAL
SIGNAL FOR
CONTACTOR COIL
KS TERMINAL IS DE-ENERGIZED
IN FIRE CONDITION.
ST
N1
NEUTRAL FROM SHUNT COIL
HOT TO SHUNT COIL
SHUNT COIL
KS
N1
NEUTRAL_TO_CONTACTOR_COIL
HOT_TO_CONTACTOR_COIL
CONTACTOR_COIL
SPARE CONTACTS WILL MAKE
CONTROL PANEL
ON/OFF WITH
DRY CONTACT
SUPPLY FAN
COMMON TO NORMALLY OPEN
WHEN SUPPLY FAN IS ON.
GROUP 1
SFC1
SFO1
COMMON
NORMALLY OPEN
SFC2
SFO2
COMMON
NORMALLY OPEN
CONTROL PANEL
EXTERNAL
TO
SWITCH
SIGNAL SWITCH THROUGH BMS
WILL ACTIVATE ZONE1 FANS AND
LIGHTS
H1
IO1
BMS SWITCH
C NO
CONTROL PANEL
GAS VALVE
TO
24V DC ONLY
ONLY ENERGIZED THROUGH LCD
HMI WHEN FIRE SYSTEM ARMED.
(NOT NEEDED IF USING 120V
GAS VALVE).
LGV
N1D
POSITIVE TO GAS VALVE
NEGATIVE
GAS SOLENOID
CONTROL PANEL TO FIRE SYSTEM
Responsibility: ALARM CONTRACTOR
CONTROL PANEL COMPONENT
CONTROL PANEL
BUILDING
SIGNAL FOR
FIRE ALARM
PANEL
AL1
AL2
J9
BUILDING
ALARM PANEL
FIRE INPUT
WIRE DIRECTLY TO CORE CIRCUIT
BOARD. AL1 WILL MAKE AL2 IN FIRE
CONDITION.
CONTROL PANEL
BUILDING
SIGNAL FOR
TROUBLE
TROUBLE RELAY CONTACTS WILL
MAKE TBC TO TBL IN TROUBLE
CONDITION.
BUILDING
ALARM PANEL
ALARM
TBC
TBL
COMMON
NORMALLY CLOSED
CONTROL PANEL TO FIRE SYSTEM
Responsibility: CERTIFIED INSTALLER
CONTROL PANEL COMPONENT
FIRE STAT SUPERVISED LOOP
May be mixed factory and field
wiring. See Installation Schematic.
Multiple fire sensors possible.
HIGH TEMP WIRE (842 F), PN:
SLPCON-xFT required for all
Supervised Loop wiring in contact
with a hood. All other wiring shall
be PN: 6320UL, Belden or similar.
21
22
23
24
FS-01
BK WH
Fire Stat
FS-02
BK WH
Fire Stat
CONTROL PANEL
MOUNTED FIRE
TO DUCT
DETECTION
STAT(S)
FIRE STATS
CONTROL PANEL
SYSTEM PULL
TO FIRE
STATION
MANUAL ACTUATION LOOP / REMOTE FIRE
SYSTEM LOOP.
Multiple manual actuation possible.
Multiple manual actuation possible.
A Plug jumper with wires from pin1 to
pin4 and from pin2 to pin3 is mounted on
J10, remove the jumpers and
wire in the supervised actuation loop.
Microswitch MS-01 is optional for fire
system interlock.
Auxiliary Interlock (AUX-01):
Wire AU1 / AU2 of adjacent Master FS
panel(s) in each manual activation loop
for simultaneous activation. See Fire
system drawings for more information.
101
102
103
104
AUX-01
AU1 AU2
PULL STATION
MS-01
C NO
Micro SW
MAD-01
C NO
Manual
Actuation
Device
Adjacent
FS
Panel
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
e
c
o
n
a
i
r
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NFP
A
WIT
H
IN
S
LI
D
TE
R
C
U
S
MASTER DRAWING
3/4" = 1'-0"
6037327
10
JG
6/6/2023
Ea
s
t
e
r
n
L
A
&
O
r
a
n
g
e
C
t
y
M
e
c
h
30
0
2
D
o
w
A
v
e
n
u
e
,
S
u
i
t
e
2
0
2
,
T
u
s
t
i
n
,
C
A
,
9
2
7
8
0
P
H
O
N
E
:
(
7
1
4
)
5
0
3
-
0
7
7
7
E
M
A
I
L
:
r
e
g
1
4
4
@
e
c
o
n
a
i
r
.
c
o
m
Ta
i
e
r
R
e
s
t
a
u
r
a
n
t
-
A
r
c
a
d
i
a
Ar
c
a
d
i
a
,
C
A
,
9
1
0
0
7
40
0
S
o
u
t
h
B
a
l
d
w
i
n
A
v
e
n
u
e
,
S
u
i
t
e
2
3
1
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
JOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
6037327
Taier Restaurant - Arcadia
SC-E100111MA
6/6/2023
INSTALL
ECP #2-2
Mixed Voltage w/ control for 1 3Ph Exhaust Fan, 1 120V 1Ph Supply Fan, Exhaust on in Fire, Lights out in Fire,
Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for
field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD.
CAT-5 CONNECTIONCONTROL PANEL
MASTER FS
TO
BOARD.
PLACE END OF LINE PLUG
EOL120A
IN EMPTY JACK. PN: EOL120A
CORE PCB
ADDITIONAL DEVICES MAY BE INLINE.
ECPM03
UNLESS VFD, PCU,
OR OTHER COMPONENT IN SERIES.
J3 J5
J6
CONTROL PANEL
MASTER FS
TO
PANEL
WIRE TO LIKE TERMINALS IN ALL
CORE PANELS THAT MUST ACTIVATE
TOGETHER. SET MASTER & SLAVE
DIP SWITCHES PER FIRE SYSTEM
SHIELDED TWISTED PAIR
INTERLOCK NETWORK MASTER CORE
MANUAL.
CA
CB
CC
BLACK
RED
SHIELD
CA
CB
CC
TANK PROTECTION ELECTRICAL DETAIL
02/10/2021 Rev. 2
ELECTRICIAN:
1. WIRE MAIN CONTROL PANEL PER INCLUDED SCHEMATIC
2. WIRE ALL FANS PER INCLUDED SCHEMATIC
3. WIRE SHUNT TRIP BREAKER (OPTIONAL)
4. WIRE UDS APPLIANCE KILL SWITCH, IF EQUIPPED (OPTIONAL)
5. WIRE GAS VALVE
NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS
EXHAUST HOOD
36 INCHES CLEARANCE REQUIRED IN FRONT
OF ALL UTILITY CABINET DOORS
THE PANEL SHALL ALSO BE LOCATED IN AN
ACCESSIBLE AREA WHERE THE AUDIBLE AND
VISUAL ALARMS CAN BE HEARD AND SEEN
GASELECTRIC
ELECTRICAL CONTRACTOR REQUIREMENT
ITEM CONNECTION IN PANEL CONNECTION IN DEVICE VOLTAGE AMPERAGE COMMENTS
SHUNT TRIP BREAKER (OPTIONAL)ST & N1
BREAKER COIL
(A1 & A2)
120 VAC < 4 AMPS ST TO A1 ON SHUNT BREAKER COIL, AND NEUTRAL TO A2 ON SHUNT TRIP BREAKER COIL
CONTROL PANEL POWER H1 & N1 + GROUND CIRCUIT BREAKER 120 VAC 15 AMPS CONTROL PANEL POWER MUST NOT BE RUN THROUGH SHUNT TRIP BREAKER
UDS APPLIANCE KILL SWITCH (OPTIONAL)KTS & N1 KTS & N1 120 VAC < 4 AMPS KILL SWITCH TERMINALS MUST BE IN SERIES WITH OTHER KILL SWITCHES
REMOTE 120VAC ANSUL AUTOMAN (OPTIONAL)AU1, AU2 SOLENOID 120 VAC < 6 AMPS 120V TO AU1, AU2 TO ANSUL ELECTRIC AUTOMAN, ANSUL SOLENOID TO NEUTRAL
GAS VALVE
LGV & N1D (IF 24 VDC)
GAS & N1 (IF 120 VAC)
RED/RED/GREEN
24 VDC
OR 120 VAC
< 1.0 AMPS
IF 24 VDC - 2 WIRES & GROUND, N1D TO RED, LGV TO RED, AND GREEN TO GROUND
IF 120 VAC - 2 WIRES & GROUND GAS TO RED, N1 TO RED, AND GREEN TO GROUND
SHUNT TRIP BREAKER (OPTIONAL)
-2 WIRES, 120VAC
-ST TO A1 ON SHUNT BREAKER
-NEUTRAL TO A2 ON SHUNT TRIP
BREAKER
POWER TO ELECTRIC
APPLIANCE
CONTROL PANEL POWER
-2 WIRES & GROUND
-120 VAC, 15 AMP SERVICE
-WIRE TO H1 AND N1, GROUND
-POWER MUST NOT ORIGINATE
FROM SHUNT TRIP BREAKER
GAS VALVE POWER
-2 WIRES & GROUND
-24 VDC WIRE TO LGV & N1D
-120 VAC WIRE TO GAS &N1
GAS VALVE
-STRAINER MUST BE
INSTALLED UPSTREAM
OF VALVE
COOKING
APPLIANCE(S)
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
JOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
6037327
Taier Restaurant - Arcadia
SC-E100111MA
6/6/2023
INSTALL
ECP #2-3
Fire System #2 TANK FS - 4.0.
FS-2: MASTER
TANK PROTECTION LOW-VOLTAGE DETAIL
02/10/2021 Rev. 2
ALARM CONTRACTOR:
1. WIRE MANUAL ACTUATION DEVICE(S), REMOTE FIRESTAT(S), CORE INTERLOCK(S), FIRE SENSOR(S) AND FIRE ALARM CONTACTS
2. COMPLETE FINAL HOOKUP OF SYSTEM
3. VERIFY FINAL FIRE SYSTEM TEST
ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD
BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES
36 INCHES CLEARANCE REQUIRED IN FRONT
OF ALL UTILITY CABINET DOORS
THE PANEL SHALL ALSO BE LOCATED IN AN
ACCESSIBLE AREA WHERE THE AUDIBLE AND
VISUAL ALARMS CAN BE HEARD AND SEEN
EXHAUST HOOD
ELECTRIC GAS
NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS
ALARM CONTRACTOR REQUIREMENT
ITEM CONNECTION IN PANEL CONNECTION ON DEVICE VOLTAGE AMPERAGE COMMENTS
MANUAL ACTUATION DEVICE(S)
101 AND 104
102 AND 103
1 & 2 24 VDC < 1.0 AMPS
WIRE MANUAL ACTUATION DEVICE TERMINAL 1 BETWEEN CORE PANEL TERMINALS 102 AND 103
WIRE MANUAL ACTUATION DEVICE TERMINAL 2 BETWEEN CORE PANEL TERMINALS 101 AND 104
JUMPER 101 TO 104 AND 102 TO 103 IF NO MANUAL ACTUATION DEVICE IS INSTALLED
MANUAL ACTUATION DEVICE COVER N/A N/A N/A N/A
MANUAL ACTUATION DEVICE COVER MUST BE INSTALLED
IF SURFACE MOUNTED, USE COVER EXTENSION STI-6531B
REMOTE FIRESTAT SENSOR(S)
21 AND 24
22 AND 23
BLACK AND WHITE 24 VDC < 1.0 AMPS
WIRE FIRE SENSOR WHITE WIRES BETWEEN HOOD CORE PANEL TERMINALS 22 AND 23
WIRE FIRE SENSOR BLACK WIRE BETWEEN HOOD CORE PANEL TERMINALS 21 AND 24
HIGH TEMP (842°F) #CW04427 (WHT) & #CW04427B (BLK)WIRE OR SIMILAR ONLY IF RAN OVER TOP
OF HOOD; OTHERWISE BELDEN #6320UL OR SIMILAR PLENUM RATED WIRE; SEE FIGURE 1
FIRE ALARM CONTACT AL1, AL2 VARIES
50V MAX
(AC/DC)
UP TO 1 AMP
FIRE ALARM RELAY CONTACTS FOR BUILDING FIRE ALARM LOCATED IN THE
CORE ELECTRICAL CONTROL PANEL
CORE INTERLOCK(S)ILA, ILB, ILC ILA, ILB, ILC
RS-485 COMMUNICATIONS
SIGNAL
CORE SYSTEM (1) ILA, TO CORE SYSTEM (2) ILA. CORE SYSTEM (1) ILB, TO CORE SYSTEM (2) ILB.
CORE SYSTEM (1) ILC, TO CORE SYSTEM (2) ILC. USE BELDEN# 88760 OR SIMILAR WIRE
TROUBLE CONTACT TBC, TBL, TOK VARIES MAX 120 VAC
UP TO 6
AMPS
WIRE TO TBL & TBC NORMALLY OPEN CONTACT, CLOSES IN TROUBLE CONDITION
CORE COMMUNICATIONS CABLE RJ-45 Jack INTERNET CONNECTION SIGNAL <1.0 AMPS
TYPICAL CONNECTION CAT5 CABLE TO LOCAL AREA NETWORK VIA ETHERNET SWITCH OR
WIRELESS ROUTER WITH VALID INTERNET CONNECTION
42 TO 48 INCHES
ABOVE FLOOR
LEVEL TO
CENTER OF PUSH
STATION
MANUAL
ACTUATION
DEVICE
10 TO 20
FEET FROM
HOOD LOCATED
NEAR POINT
OF EGRESS
FROM HOOD
MANUAL ACTUATION DEVICE WIRES
-4 WIRES, 24VDC WIRE (TERMINAL 1)
BETWEEN 102 AND 103
-WIRE (TERMINAL 2) BETWEEN 101 AND 104
-ADDITIONAL PULL STATIONS WIRED IN
SUPERVISED LOOP
-USE BELDEN #6320UL OR SIMILAR WIRE
-SEE FIGURE 2
MANUAL ACTUATION DEVICE
PART #STI-SS2431
PROTECTIVE COVER MUST BE INSTALLED
SUPERVISED LOOP
-4 WIRES, 24VDC CONNECT BLACK
WIRES BETWEEN 21 AND 24 IN PANEL,
CONNECT WHITE (OR RED) WIRES
BETWEEN 22 AND 23 IN PANEL
-ADDITIONAL FIRESTATS, WIRED IN
SUPERVISED LOOP
-USE HIGH TEMP (842°F) #CW04427
(WHT) & #CW04227B (BLK)WIRE ONLY
IF RAN OVER TOP OF HOOD;
OTHERWISE BELDEN #6320UL OR
SIMILAR PLENUM RATED WIRE
-SEE FIGURE 1
CORE COMMUNICATIONS CABLE
-CAT5 CABLE
MUST BE INSTALLED TO A LOCAL AREA
NETWORK WITH VALID INTERNET ACCESS
VIA ETHERNET SWITCH OR WIRELESS
ROUTER
CORE INTERLOCK
-2 WIRES + SHIELD
-USE BELDEN#88760 OR SIMILAR WIRE
-SEE FIGURE 3
FIRE ALARM PANEL
FIRE ALARM CONTACT
-2 WIRES WIRED TO NORMALLY
OPEN CONTACTS (CLOSES IN
FIRE CONDITION)
-CORE CONTROL PANEL AL1
AND AL2
-SEE FIGURE 2
TROUBLE CONTACT
-2 WIRES TO NORMALLY
OPEN CONTACTS (CLOSE
IN TROUBLE CONDITION)
-CORE PANEL TERMINALS
TBL AND TBC
-SEE FIGURE 4
COOKING
APPLIANCE(S)
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
JOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
6037327
Taier Restaurant - Arcadia
SC-E100111MA
6/6/2023
INSTALL
ECP #2-4
Fire System #2 TANK FS - 4.0.
FS-2: MASTER
TANK PROTECTION LOW-VOLTAGE FIGURES
02/10/2021 Rev. 17
AL1
AL2 END
OF
LINE
DEVICE
WIRING CONNECTIONS FOR FIRE
ALARM CONTACT
FIGURE 2
CORE
CONTROL
PANEL
FIRE
ALARM
CONTACT
ALARM
INPUT
BUILDING
FIRE ALARM
SHIELDED TWISTED PAIR
ILA
ILC
ILB
ILA
BK
ILB
RD
BK
RD
WIRING CONNECTIONS
FOR CORE INTERLOCK
FIGURE 3
ILC
ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD
BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES
SUPERVISION
SWITCH
1 2
C
BUILDING
FIRE ALARM
TROUBLE
INPUT
CORE
CONTROL
PANEL
TROUBLE CONTACT
NO
C
NC 1
C
2
SUPERVISION
SWITCH
SUPERVISION
SWITCH
END
OF
LINE
DEVICE
TBC
TBLTOK
WIRING CONNECTIONS FOR
TROUBLE CONTACT
FIGURE 4
BK-C
BK-C
21
22
23
24
J2-1
J2-2
J2-4
J2-3
21
BK-C
101
102
103
104
J10-1
J10-2
J10-4
J10-3
21
BK-C
WIRING CONNECTIONS
FOR FIRESTAT LOOP
FIGURE 1
WIRING CONNECTIONS
FOR MANUAL ACTUATION LOOP
FIGURE 1A
BREAK WIRE
BEFORE
INSERTING
INTO
TERMINALS
FIRE
STAT-2
FIRE
STAT-1 NO-WH
(OR RD)
NO-WH
(OR RD)
BREAK WIRE
BEFORE
INSERTING
INTO
TERMINALS
NO-WH
(OR RD)
MANUAL
ACTUATION
DEVICE
NO-WH
(OR RD)
MANUAL
ACTUATION
DEVICE
MICROSWITCH/
NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS
USE BELDEN #6320UL
OR SIMILAR WIRE
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
JOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
6037327
Taier Restaurant - Arcadia
SC-E100111MA
6/6/2023
INSTALL
ECP #2-5
Fire System #2 TANK FS - 4.0.
FS-2: MASTER
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
e
c
o
n
a
i
r
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NFP
A
WIT
H
IN
S
LI
D
TE
R
C
U
S
MASTER DRAWING
3/4" = 1'-0"
6037327
11
JG
6/6/2023
Ea
s
t
e
r
n
L
A
&
O
r
a
n
g
e
C
t
y
M
e
c
h
30
0
2
D
o
w
A
v
e
n
u
e
,
S
u
i
t
e
2
0
2
,
T
u
s
t
i
n
,
C
A
,
9
2
7
8
0
P
H
O
N
E
:
(
7
1
4
)
5
0
3
-
0
7
7
7
E
M
A
I
L
:
r
e
g
1
4
4
@
e
c
o
n
a
i
r
.
c
o
m
Ta
i
e
r
R
e
s
t
a
u
r
a
n
t
-
A
r
c
a
d
i
a
Ar
c
a
d
i
a
,
C
A
,
9
1
0
0
7
40
0
S
o
u
t
h
B
a
l
d
w
i
n
A
v
e
n
u
e
,
S
u
i
t
e
2
3
1
WH
BK
A B C D E F G H I
1
2
3
4
5
6
7
8
9
10
FACTORY WIRING
SCHEMATIC
CIRCUIT BOARDS
PANEL LID
COMPONENT LIST
LABEL DESCRIPTION
ST-X
varies
Starter
OL-X
varies
Overload
C-X
varies
Contactor
TS-x
A/CP-PO-T4"-EXPL
Duct Thermostat
120 VAC
RELAY
NO
COM
COIL
NC
34
6 5
8
2
7
1
RA-x
24 VDC
RELAY
RD-x
NO
COM
COIL
NC
34
6 5
8
2
7
1
PS-1
MDP18-24A-1C
Power Sup. 24VDC
BK
RA-x
34.110.0184.0
120V Relay DPDT
WH
RA-x
34.110.0184.0
120V Relay DPDT
GR
UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG.
N1
H1
DC
-
GN
D
DC
+
8H1
7PCU
6ST
5KS
4KTS
3GAS
2AR1
1N1
120VJ9
5OV1
4SF1
3EF1
2B1
1IO1
120VJ7
AR1
H1
2x
N1
2x
B1
EF1
SF1
BK
IO1
N1
BK
BK
BK
JUMPER
W1
BK 14AWG BK
64
RD-1
BL PR
DC+RO1
RD-x
34.110.0188.0
24VDC Light Relay
BK WH
SF1 7 8RA-2
A1 A2C-1
8 7RD-1
24V
1 2 3 4 5 6 7
8 9 10 11121314
J6
N1
ON/OFF
WITH
SUP
N1
RO
1
NH
FAN
PANEL COOLING
DRY CONTACTS (SHOWN DE-ENERGIZED)
HOOD LIGHTS
AR1 H1
JUMPER FIRE SYSTEM
BK
BK
BK
GAS
KS
ST
NOTE: Configure ECPM03 for CORE
ECPM03
J10
IL
1
A
IL
1
B
JUMPER
MAKE UP AIR INTERLOCK.
J3
ECPM03 or Previous EOL
J5
MASTER CORE
C
RA-2-1
NO
SFC1
SFO1
14 AWG
YW
C
RA-2-2
NO
SFC2
SFO2
14 AWG
YW
24 X 18 X 8.62 BOX
CONTROL INPUT 120V
H1=LINE, N1=NEUTRAL,
15A BREAKER. DO NOT
CONNECT TO SHUNT TRIP
BREAKER. SEE
INSTALLATION SCHEMATIC
FOR ADDITIONAL REQ.
LEGEND
FIELD WIRING
FACTORY WIRING
BK- BLACK
BL- BLUE
BR- BROWN
OR- ORANGE
WH- WHITE
OR/BL- OR/BL STRIPE
BL/RD- BL/RD STRIPE
RD/GN- RD/GN STRIPE
WH/BL- WH/BL STRIPE
YW- YELLOW
GY- GREY
PR- PURPLE
RD- RED
GR- GREEN
WH
/
B
L
BL
H1N1
DC
-
DC
+
LN
-+
PS-01
AC
24V
GN
D
DC
KSKS
BK
KS
BK
BK
GAS
ST
P1
A
(
+
)
P1
B
(
-
)
N/A
69.0%
BK
EF1
PR
WH
GR
/
Y
W
WH
/
B
L
BL
NH
FAN
SECONDARY PANEL COOLING IF NECESSARY
EF1
WHBK
JUMPER
ECPM03
J10
IL
2
A
IL
2
B
TERMINAL GAS USED FOR
120V POWERED GAS
VALVES ONLY
DWG NO
JOB NO
DATE
DRAWN BY
JOB NAME
DESCRIPTION OF OPERATION
TYPE
DRAWING TITLE
6037327
Taier Restaurant...
FACTORY
SC-E100111MA
6/6/2023
ECP #2-6
Mixed Voltage w/ control
for 1 3Ph Exhaust Fan,
1 120V 1Ph Supply Fan,
Exhaust on in Fire,
Lights out in Fire, Relay
On/Off with Supply Fan,
Fan(s) On/Off
Thermostatically
Controlled. Room
temperature sensor
shipped loose for field
installation. INVERTER
DUTY 3 PHASE MOTOR
REQUIRED FOR USE WITH
VFD.
A B C D E F G H I
1
2
3
4
5
6
7
8
9
10
FACTORY WIRING
SCHEMATIC
CIRCUIT BOARDS
DCV Rev. 2.10.00
HMI Rev. 2.10.00
MOTOR POWER CIRCUITS. SEE INSTALLATION
COMPONENT LIST
LABEL DESCRIPTION
ST-X
varies
Starter
120 VAC
RELAY
NO
COM
COIL
NC
34
6 5
8
2
7
1
RA-x
24 VDC
RELAY
RD-x
NO
COM
COIL
NC
34
6 5
8
2
7
1
24 X 18 X 8.62 BOX
DIAGRAM FOR FIELD WIRING REQUIREMENTS.
C-X
varies
Contactor
SM-X
varies
VFD
LEGEND
FIELD WIRING
FACTORY WIRING
BK- BLACK
BL- BLUE
BR- BROWN
OR- ORANGE
WH- WHITE
OR/BL- OR/BL STRIPE
BL/RD- BL/RD STRIPE
RD/GN- RD/GN STRIPE
WH/BL- WH/BL STRIPE
YW- YELLOW
GY- GREY
PR- PURPLE
RD- RED
GR- GREEN
LR-X
varies
Line/Load Reactor
DWG NO
JOB NO
DATE
DRAWN BY
JOB NAME
DESCRIPTION OF OPERATION
TYPE
DRAWING TITLE
6037327
Taier Restaurant...
FACTORY
SC-E100111MA
6/6/2023
ECP #2-7
Mixed Voltage w/ control
for 1 3Ph Exhaust Fan,
1 120V 1Ph Supply Fan,
Exhaust on in Fire,
Lights out in Fire, Relay
On/Off with Supply Fan,
Fan(s) On/Off
Thermostatically
Controlled. Room
temperature sensor
shipped loose for field
installation. INVERTER
DUTY 3 PHASE MOTOR
REQUIRED FOR USE WITH
VFD.
BK
WH
T1
T2
T3
L1
L2
L3
1413
CONT:
FLA:
MTR:
HP:
L1
FN1
C-114 AWG
1 PH
15 A
115 V
SUP-7
100-K09D10
5.8
0.333
A B C D E F G H I
1
2
3
4
5
6
7
8
9
10
FACTORY WIRING
SCHEMATIC
CORE FIRE
PROTECTION
COMPONENT LIST
LABEL DESCRIPTION
120 VAC
RELAY
NO
COM
COIL
NC
34
6 5
8
2
7
1
RA-x
24 VDC
RELAY
RD-x
NO
COM
COIL
NC
34
6 5
8
2
7
1
24 VOLT BATTERY PACK
5 AMP FUSE
RD
SHIELDED TWISTED PAIR
PCB-2
J3-2
J4-1
J3-11
J4-3
J4-2
J4-8
J4-9
J4-12
J3-14
J4-5
J3-13
J3-4
J4-6
J3-10
J2-1
J2-2
J2-3
J2-4
J7-2
J7-3
J7-1
J3-1 J3-3
RD
RD BR
RD
ALL 18AWG
RD BK
ORRD
PKRD
BRRD
RD OR/BL
BK 18AWG
BK
BK
J3-5
J1-1
J1-2
RD
BK
BK
RD
FIRE STAT SUPERVISED LOOP
May be mixed factory and field
wiring. See Installation Schematic.
Multiple fire sensors possible.
+
+
RD
BK
BK
RD
Shield
BK
RD
RS-485 CORE INTERLOCK
NETWORK. Connection to
other CORE Panels or
Communication Module. See
Installation Schematic for
Connection.
N1D 3xH1D3x
DISCONNECT J1
21
22
23
24
16AWG
WH
N1
H1
PN: 1606-XLP-60EQ
Adjust power supply to 27.5
Volts with an accurate
Digital Volt Meter or with an
HMI plugged into the CORE
board.
NL
+-
PSM-2 60W
GR
BK
GND
PCB-2
PCBCORE-APP
CORE PCB
PSM-2
1606-XLP-50E
CORE POWER SUPPLY
WS-x
varies
Water Solenoid
LT-06
PNL-1163-0UR
24V Red Ind. Light
LL-01
AQ5510
Surf. Level Sensor
AA-01
SCE120LA3FP1B
Audible Alarm
PB-01
D7-F2X11
Prime/Reset Switch
SW-04
BZ-2RQ1-A2
Tamper Switch
SP-1
50000-805
Surfactant Pump
PB-01
Prime / Reset
A2A1
RD-20
Trouble Relay
A2A1
RD-17
Fire Relay
DRY CONTACTS (SHOWN DE-ENGERGIZED)
AA-01
Audible Alarm
SW-04
Door Tamper Switch
C NO
FS-01
BK WH
Fire Stat
FS-02
BK WH
Fire Stat
HIGH TEMP WIRE (842 F),
PN: SLPCON-xFT required
for all Supervised Loop
wiring in contact with a
hood. All other wiring
shall be PN: 6320UL,
Belden or similar. Factory
mounted hood sensors will
be terminated at junction
box on top of hood.
GV-1
varies
24v DC Gas Valve
INTERLOCK FOR AUTOMAN ACTIVATION.
Used for activating 120V automan
or adjacent Master CORE panels
during active Fire Condition.11
RD-18-1
14
YW
J3-16
J3-8
BR
38
LT-6
R
FIRE INDICATOR
DIP Switch
ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD
BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES.
RD/GNRD
A2A1
RD-19
Equipment Relay COOKING EQUIPMENT DISABLE RELAY.
For UDS Kill Switch, wire EKC and
EKS terminals to like terminals in
UDS panel.
12
11
RD-19-1
14
EKC
EST
EKS
YW
INTERLOCK FOR AUTOMAN ACTIVATION.
Used for activating 120V automan
or adjacent Master CORE panels
during active Fire Condition.11
RD-18-1
14
YW
RD OR/BL
A2A1
RD-18
Auxiliary Interlock Relay
FS-XX
12-F28021-000360
Duct Fire Sensor
LT-05
PNL-1163-0UY
24V YLW Ind. Light
PS-01
Station STI-SS2431
Remote Puill/Push
FOR SHIPMENT
J10-1
J10-2
J10-3
J10-4
RD
BK
BK
RD
101
102
103
104
MANUAL ACTUATION LOOP / REMOTE FIRE
SYSTEM LOOP.
Multiple manual actuation possible.
A Plug jumper with wires from pin1 to
pin4 and from pin2 to pin3 should be
mounted on J10 if there is no manual
actuation device and no microswitch.
Jumper if water valve
supervision switch is used
MAD-01
C NO
Manual
Actuation
Device
MS-01
C NO
Micro SW
1 2 3 4 5 6 7 8
SW
1
OPEN
PUT END OF LINE PLUG IN EMPTY RJ45
J3
ECPM03
UNLESS PCU AFM OR OTHER COMPONENT IN SERIES.
CAT-5 WIRING (MASTER ONLY)
FIELD WIRED IF REMOTE PREWIRE
RD-XX
PLC-RPT-24DC/21
24VDC Phoenix Relay
AUX-01
AU1 AU2
Auxiliary Interlock (AUX-01):
Wire AU1 / AU2 of adjacent Master CORE
panel(s) in each manual activation loop
for simultaneous activation.
AU1/AU2 will have continuity for 10
seconds if adjacent panel goes into fire
condition, activating this CORE Panel but
allowing for a reset after 10 seconds.
NOTE: AU1/AU2 terminals of CORE Panel
should not be wired into its own manual
activation loop.
Adjacent
CORE
Panel
Master CORE
set DIP SW 8
to CLOSED
position. Slave
CORE with
address 1 set
DIP SW 8 to
CLOSED
position. All
other CORES
set DIP SW 8
OPEN.
18AWG
LEGEND
FIELD WIRING
FACTORY WIRING
BK- BLACK
BL- BLUE
BR- BROWN
OR- ORANGE
WH- WHITE
OR/BL- OR/BL STRIPE
BL/RD- BL/RD STRIPE
RD/GN- RD/GN STRIPE
WH/BL- WH/BL STRIPE
YW- YELLOW
GY- GREY
PR- PURPLE
RD- RED
GR- GREEN
FIRE INDICATOR FAULT CONDITION FLASH CODES
2 Release Solenoid
3 Pressure Switch
4 Auxiliary Fault
5 Microcontroller Fault
6 N/A
7 Supervised Loop
8 Ground Fault
9 Surfactant Low
10 Battery Voltage Low
11 AC Power Failure
12 Door Tamper Switch
13 Test Mode
14 CORE Interlock Network
15 Fault on Hood in Interlock Network
16 Fault on PCU in Interlock Network
FIRE ALARM SYSTEM DRY CONTACTS.
Termials AL1 & AL2 make in FIRE.
To Building Fire
Alarm Panel
J9
AL1
AL2
J3-7
FIRE SYSTEM DRY CONTACTS.
Dry contacts will make C2 to AR2
when system is armed.
12
11
RD-17-1
C2
AR2
14 AWG
YW
TROUBLE RELAY. Contact terminals
TBC & TBL make if there is trouble.
Contact terminals TBC & TOK make if
the system is ok.
12
11
RD-20-1
14
TBC
TBL
TOK
YW
RD
PS
OR
J4-9
PS
EWC-PRESSURE
Pressure Switch
PR
RS
SW-05-1
Test Armed
3 4 YW
RS-1
RELEASE SOLENOID
BLBR
RD OR
SW-05-2
Test Armed
3 4 J4-13
SW-05
ZB5AD2
TEST/ARM Switch
RS2
PR
SW-05-1
Test Armed
3 4 YW
PS-1
Pressure Switch
WH
14
PWS-01
24VDC 18W POWER
24VDC Power Suppl
CA
CB
CC
AU1AU1
AU2AU2
TR2
MAD-01
DEVICE
MANUAL ACTIVATION
GAS VALVES SHOULD BE WIRED
TO MASTER CORE BOARD ONLY.
RDRD
GV-1
24V DC Gas Valve
LGV
PK TERMINAL LGV USED FOR 24VDC
POWERED GAS VALVES ONLY.
DWG NO
JOB NO
DATE
DRAWN BY
JOB NAME
DESCRIPTION OF OPERATION
TYPE
DRAWING TITLE
6037327
Taier Restaurant...
FACTORY
SC-E100111MA
6/6/2023
ECP #2-8
Fire System #2 TANK FS
- 4.0.
FS-2: MASTER
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
e
c
o
n
a
i
r
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NFP
A
WIT
H
IN
S
LI
D
TE
R
C
U
S
MASTER DRAWING
3/4" = 1'-0"
6037327
12
JG
6/6/2023
Ea
s
t
e
r
n
L
A
&
O
r
a
n
g
e
C
t
y
M
e
c
h
30
0
2
D
o
w
A
v
e
n
u
e
,
S
u
i
t
e
2
0
2
,
T
u
s
t
i
n
,
C
A
,
9
2
7
8
0
P
H
O
N
E
:
(
7
1
4
)
5
0
3
-
0
7
7
7
E
M
A
I
L
:
r
e
g
1
4
4
@
e
c
o
n
a
i
r
.
c
o
m
Ta
i
e
r
R
e
s
t
a
u
r
a
n
t
-
A
r
c
a
d
i
a
Ar
c
a
d
i
a
,
C
A
,
9
1
0
0
7
40
0
S
o
u
t
h
B
a
l
d
w
i
n
A
v
e
n
u
e
,
S
u
i
t
e
2
3
1