HomeMy WebLinkAbout400 S Baldwin Ave - 2023 - Taier ElectricalEastern LA & Orange Cty Mech REGION 144 PHONE: (714) 503-0777 EMAIL: reg144@econair.com FOR QUESTIONS, CALL THE HOOD INFORMATION - JOB#6037327 1 2 3 4 5 L R 5424 EX-2 5424 EX-2 5424 EX-2 4824 ES-VHB 4824 ES-VHB ECON-AIR ECON-AIR ECON-AIR ECON-AIR ECON-AIR 12' 0" 11' 11" 7' 11" 4' 0" 3' 0" 600 DEG 600 DEG 600 DEG 700 DEG 700 DEG I I I II II HEAVY HEAVY HEAVY N/A N/A 300 302 227 200 200 3600 3600 1800 800 600 4" 4" 4" 4" 4" 18" 18" 14" 12" 10" 3600 3600 1800 800 600 2037 2037 1684 1019 1100 -0.685" -0.692" -0.387" -0.118" -0.090" 430 SS WHERE EXPOSED 430 SS WHERE EXPOSED 430 SS WHERE EXPOSED 430 SS 100% 430 SS 100% LEFT RIGHT ALONE ALONE ALONE ALONE ALONE ALONE ALONE ALONE HOOD NO TAG MODEL MANUFACTURER LENGTH MAX COOKING TEMP TYPE APPLIANCE DUTY DESIGN CFM/FT TOTAL EXH CFM EXHAUST PLENUM RISER(S) WIDTH LENG HEIGHT DIA CFM VEL SP HOOD CONSTRUCTION HOOD CONFIG END TO END ROW HOOD INFORMATION 1 2 3 4 5 L R SS BAFFLE WITH HANDLES SS BAFFLE WITH HANDLES SS BAFFLE WITH HANDLES 9 8 5 20" 20" 20" 16" 16" 16" 30% 30% 30% 4 4 3 0 0 L55 SERIES E26 L55 SERIES E26 L55 SERIES E26 NO NO NO LEFT WALL MNT LEFT 12"x54"x24" 12"x60"x24" 12"x54"x24" TANK FS TANK FS 4.0/4.0/4.0/4.0 4.0 SC-E200111MA SC-E100111MA 1 LIGHT 1 FAN 1 LIGHT 1 FAN YES YES YES NO NO 600 LBS 433 LBS 527 LBS 155 LBS 139 LBS HOOD NO TAG FILTER(S) TYPE QTY HEIGHT LENGTH EFFICIENCY @ 7 MICRONS LIGHT(S) QTY TYPE WIRE GUARD UTILITY CABINET(S) LOCATION SIZE FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL # SWITCHES QUANTITY FIRE SYSTEM PIPING HOOD HANGING WEIGHT HOOD OPTIONS 1 2 3 L R LEFT VERTICAL END PANEL 27" TOP WIDTH, 21" BOTTOM WIDTH, 80" HIGH INSULATED 430 SS. RIGHT END STANDOFF (FINISHED) 1" WIDE 54" LONG INSULATED. RIGHT WALL AS END PANEL. RIGHT END STANDOFF (FINISHED) 1" WIDE 54" LONG INSULATED. RIGHT WALL AS END PANEL. HOOD NO TAG OPTION WALL-MOUNT UTILITY CABINET 1 WALL MNT 12"x60"x24"TANK FS 4.0/4.0/4.0/4.0 500.00 LBS UTILITY CABINET(S) HOOD NO LOCATION SIZE FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL # SWITCHES QUANTITY WEIGHT 7' 11"NOM./7' 11.00"OD. 9'-0.00" OVERALL LENGTH 54" 12" 1" LAYER OF INSULATION FACTORY INSTALLED IN 1.00" END STANDOFF MEETS 0" REQUIREMENTS CLEARANCE TO COMBUSTIBLE SURFACES. 1" § 47 1/2"47 1/2" 11" ∅14" U.L. LISTED L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY. INSTALLER MUST CONFIRM HOOD IS INSTALLED SUCH THAT THE SPECIFIED WALL, ACTING AS AN END PANEL, IS MATED TIGHT TO THE CORRECT END OF HOOD TO ACHIEVE A REDUCED MINIMUM EXHAUST CFM LISTING. NON-COMPLIANCE WILL NULLIFY THE ETL LISTING, VOID THE MANUFACTURER'S WARRANTY, AND HOLD THE CONTRACTOR LIABLE FOR ANY AND ALL LOSSES, COSTS, AND EXPENSES RELATED TO THE NON-CONFORMANCE OF THE MANUFACTURER'S SPECIFIED INSTRUCTION. THE WALL ACTING AS AN END PANEL MUST EXTEND NO LESS THAN 20" FROM THE INTERSECTING WALL ON WHICH HOOD IS MOUNTED AND MUST EXTEND NO LESS THAN 20" UNDER BOTTOM OF HOOD TO BE ELIGIBLE FOR REDUCED MINIMUM EXHAUST CFM LISTING. PLAN VIEW - HOOD #3 7' 11.00" LONG 5424EX-2 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. HOOD CORNER HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). HOOD CORNER HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. FULL LENGTH HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). FULL LENGTH HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR FULL LENGTH HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) 3" INTERNAL STANDOFF. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. § EXHAUST RISER. HANGING ANGLE. L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE). RIGHT WALL AS END PANEL. EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54" SECTION VIEW - MODEL 5424EX-2 HOOD - #3 IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" SS BAFFLE WITH HANDLES AND HOOK. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . e c o n a i r . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NFP A WIT H IN S LI D TE R C U S MASTER DRAWING 3/4" = 1'-0" 6037327 1 JG 6/6/2023 Ea s t e r n L A & O r a n g e C t y M e c h 30 0 2 D o w A v e n u e , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 5 0 3 - 0 7 7 7 E M A I L : r e g 1 4 4 @ e c o n a i r . c o m Ta i e r R e s t a u r a n t - A r c a d i a Ar c a d i a , C A , 9 1 0 0 7 40 0 S o u t h B a l d w i n A v e n u e , S u i t e 2 3 1 ACTUAL DIMENSIONS 19-5/8" x 19-5/8" x 1-7/8" 19-5/8" x 15-5/8" x 1-7/8" 15-5/8" x 19-5/8" x 1-7/8" 15-5/8" x 15-5/8" x 1-7/8" FILTER INFORMATION Region 144 20 x 20 16 x 20 16 x 16 20 x 16 NOM. SIZE (H x W) 2.28 11 1.78 1.39 1.78 9.1 7.4 8.9 (SQ. FEET) FREE AREA (H x W x D)(LBS) WEIGHT SOUTHERN CALIFORNIA OFFICE TUSTIN, CA 92780 PHONE: (714) 503 - 0777 REG144@CAPTIVEAIRE.COM FOR QUESTIONS, CALL THE HANGING ANGLE THROUGH ANOTHER CONNECTED TO ROOF JOIST 1/2" DIA. ALL THREAD ROD AND WASHER - ONE ABOVE 1/2" DIA. HEAVY DUTY NUT AND ONE BELOW HANGING ANGLE ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR CORNER HANGING ANGLE DETAIL ND-2 HANGING ANGLE IS PRE-PUNCHED AT FACTORY STEEL HANGING ANGLE 3002 DOW AVE., SUITE 410 CAPTRATE R RCAPTIVEAIRE CAPTRATE & KLEEN-GARD FILTERS TE A ARE BUILT IN COMPLIANCE WITH INT. MECH. CODE (IMC) UL STANDARD #1046 NSF NSF STANDARD #2 O NFPA #96 CH B N RAN I ,OR M . YR OR LAIGNTSB AT UL 710 & ULC710 STANDARDS E.T.L. LISTED 102900319PRT-001 CAPTIVE-AIRE HOODS ARE BUILT IN COMPLIANCE WITH NFPA #96 ACTUAL DIMENSIONS 19-5/8" x 19-5/8" x 1-7/8" 19-5/8" x 15-5/8" x 1-7/8" 15-5/8" x 19-5/8" x 1-7/8" 15-5/8" x 15-5/8" x 1-7/8" 2.28 1.78 1.39 1.78 (SQ. FEET) FREE AREA (H x W x D)(LBS) WEIGHT 10 12 12 1520 x 20 16 x 20 16 x 16 20 x 16 NOM. SIZE (H x W) ACTUAL DIMENSIONS 19-5/8" x 19-5/8" x 1-7/8" 19-5/8" x 15-5/8" x 1-7/8" 15-5/8" x 19-5/8" x 1-7/8" 15-5/8" x 15-5/8" x 1-7/8" 2.23 1.73 1.35 1.73 (SQ. FEET) FREE AREA (H x W x D)(LBS) WEIGHT 20 x 20 16 x 20 16 x 16 20 x 16 NOM. SIZE (H x W) GREASE-STOP SOLO FILTER INFORMATION CAPTRATE R R GREASE-STOP COMBO FILTER INFORMATION KLEEN-GARD R SS BAFFLE TYPE 11 9.1 7.4 8.9 SLI DTE R ACCORDANCE No. 96 NFPA WITH BUILT IN WITH NFPA No. 96 IN ACCORDANCE BUILT SLI DTE R LIGHT/FAN CONTROL INTERFACE 120V 15AMP CONTROL INPUT BUILDING ALARM 120V 15AMP LIGHT INPUT PRE-WIRED TO LIGHTS (TYPICAL CONNECTIONS, REFER TO DETAILED WIRING DIAGRAMS FOR RESPONSIBILITY AND CONNECTIONS) ELECTRICAL HOOD CONTROL BOX UTILITY CABINET INPUT FOR EXHAUST/SUPPLY FAN SHUNT TRIP BREAKER (BY ELECTRICIAN) OUTPUT FOR EXHAUST/SUPPLY FAN CAT-5 PREWIRED AT FACTORY TANK FIRE SYSTEM BUILDING TROUBLE 12' 0"NOM./12' 0.00"OD. 13'-0.00" OVERALL LENGTH 12" § 72"72" 12" ∅18" U.L. LISTED L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY. 11' 11"NOM./11' 11.00"OD. 12'-0.00" OVERALL LENGTH 54" 1" LAYER OF INSULATION FACTORY INSTALLED IN 1.00" END STANDOFF MEETS 0" REQUIREMENTS CLEARANCE TO COMBUSTIBLE SURFACES. 1" 3" § 71 1/2"71 1/2" 12" ∅18" U.L. LISTED L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY. INSTALLER MUST CONFIRM HOOD IS INSTALLED SUCH THAT THE SPECIFIED WALL, ACTING AS AN END PANEL, IS MATED TIGHT TO THE CORRECT END OF HOOD TO ACHIEVE A REDUCED MINIMUM EXHAUST CFM LISTING. NON-COMPLIANCE WILL NULLIFY THE ETL LISTING, VOID THE MANUFACTURER'S WARRANTY, AND HOLD THE CONTRACTOR LIABLE FOR ANY AND ALL LOSSES, COSTS, AND EXPENSES RELATED TO THE NON-CONFORMANCE OF THE MANUFACTURER'S SPECIFIED INSTRUCTION. THE WALL ACTING AS AN END PANEL MUST EXTEND NO LESS THAN 20" FROM THE INTERSECTING WALL ON WHICH HOOD IS MOUNTED AND MUST EXTEND NO LESS THAN 20" UNDER BOTTOM OF HOOD TO BE ELIGIBLE FOR REDUCED MINIMUM EXHAUST CFM LISTING. 25'-0.00" OVERALL LENGTH PLAN VIEW - HOOD #1 (L) 12' 0.00" LONG 5424EX-2 NOTE: ADDITIONAL HANGING ANGLES PROVIDED FOR HOODS 12' AND LONGER. PLAN VIEW - HOOD #2 (R) 11' 11.00" LONG 5424EX-2 3" INTERNAL STANDOFF. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. § EXHAUST RISER. HANGING ANGLE. L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE). 20" 4" 4 1/2" 21" 27" 80" LEFT VERTICAL END PANEL WITH ADJUSTABLE LEGS. GAS CHASE CUTOUT (FOR GAS AND POWER LINES). EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54" SECTION VIEW - MODEL 5424EX-2 HOOD - #1 (L) IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" SS BAFFLE WITH HANDLES AND HOOK. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . e c o n a i r . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NFP A WIT H IN S LI D TE R C U S MASTER DRAWING 3/4" = 1'-0" 6037327 2 JG 6/6/2023 Ea s t e r n L A & O r a n g e C t y M e c h 30 0 2 D o w A v e n u e , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 5 0 3 - 0 7 7 7 E M A I L : r e g 1 4 4 @ e c o n a i r . c o m Ta i e r R e s t a u r a n t - A r c a d i a Ar c a d i a , C A , 9 1 0 0 7 40 0 S o u t h B a l d w i n A v e n u e , S u i t e 2 3 1 LIGHT/FAN CONTROL INTERFACE 120V 15AMP CONTROL INPUT BUILDING ALARM 120V 15AMP LIGHT INPUT PRE-WIRED TO LIGHTS (TYPICAL CONNECTIONS, REFER TO DETAILED WIRING DIAGRAMS FOR RESPONSIBILITY AND CONNECTIONS) ELECTRICAL HOOD CONTROL BOX UTILITY CABINET INPUT FOR EXHAUST/SUPPLY FAN SHUNT TRIP BREAKER (BY ELECTRICIAN) OUTPUT FOR EXHAUST/SUPPLY FAN CAT-5 PREWIRED AT FACTORY BUILDING TROUBLE ACTUAL DIMENSIONS 19-5/8" x 19-5/8" x 1-7/8" 19-5/8" x 15-5/8" x 1-7/8" 15-5/8" x 19-5/8" x 1-7/8" 15-5/8" x 15-5/8" x 1-7/8" FILTER INFORMATION Region 144 20 x 20 16 x 20 16 x 16 20 x 16 NOM. SIZE (H x W) 2.28 11 1.78 1.39 1.78 9.1 7.4 8.9 (SQ. FEET) FREE AREA (H x W x D)(LBS) WEIGHT SOUTHERN CALIFORNIA OFFICE TUSTIN, CA 92780 PHONE: (714) 503 - 0777 REG144@CAPTIVEAIRE.COM FOR QUESTIONS, CALL THE HANGING ANGLE THROUGH ANOTHER CONNECTED TO ROOF JOIST 1/2" DIA. ALL THREAD ROD AND WASHER - ONE ABOVE 1/2" DIA. HEAVY DUTY NUT AND ONE BELOW HANGING ANGLE ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR CORNER HANGING ANGLE DETAIL ND-2 HANGING ANGLE IS PRE-PUNCHED AT FACTORY STEEL HANGING ANGLE 3002 DOW AVE., SUITE 410 CAPTRATE R RCAPTIVEAIRE CAPTRATE & KLEEN-GARD FILTERS TE A ARE BUILT IN COMPLIANCE WITH INT. MECH. CODE (IMC) UL STANDARD #1046 NSF NSF STANDARD #2 O NFPA #96 CH B N RAN I ,OR M . YR OR LAIGNTSB AT UL 710 & ULC710 STANDARDS E.T.L. LISTED 102900319PRT-001 CAPTIVE-AIRE HOODS ARE BUILT IN COMPLIANCE WITH NFPA #96 ACTUAL DIMENSIONS 19-5/8" x 19-5/8" x 1-7/8" 19-5/8" x 15-5/8" x 1-7/8" 15-5/8" x 19-5/8" x 1-7/8" 15-5/8" x 15-5/8" x 1-7/8" 2.28 1.78 1.39 1.78 (SQ. FEET) FREE AREA (H x W x D)(LBS) WEIGHT 10 12 12 1520 x 20 16 x 20 16 x 16 20 x 16 NOM. SIZE (H x W) ACTUAL DIMENSIONS 19-5/8" x 19-5/8" x 1-7/8" 19-5/8" x 15-5/8" x 1-7/8" 15-5/8" x 19-5/8" x 1-7/8" 15-5/8" x 15-5/8" x 1-7/8" 2.23 1.73 1.35 1.73 (SQ. FEET) FREE AREA (H x W x D)(LBS) WEIGHT 20 x 20 16 x 20 16 x 16 20 x 16 NOM. SIZE (H x W) GREASE-STOP SOLO FILTER INFORMATION CAPTRATE R R GREASE-STOP COMBO FILTER INFORMATION KLEEN-GARD R SS BAFFLE TYPE 11 9.1 7.4 8.9 SLI DTE R ACCORDANCE No. 96 NFPA WITH BUILT IN WITH NFPA No. 96 IN ACCORDANCE BUILT SLI DTE R UTILITY CABINET HOUSES FIRE SUPPRESSION MEASURES 60" x 24" x 12" 4' 0"NOM./4' 0.00"OD. 48" § 24"24" 24" ∅12" PLAN VIEW - HOOD #4 4' 0.00" LONG 4824ES-VHB 3' 0"NOM./3' 0.00"OD. 48" § 18"18" 24" ∅10" PLAN VIEW - HOOD #5 3' 0.00" LONG 4824ES-VHB SEE HOOD TABLE. § EXHAUST RISER. HANGING ANGLE. EQUIPMENT BY OTHERS. 80" 24" NOM. 48" SECTION VIEW - MODEL 4824ES-VHB HOOD - #4 SEE HOOD TABLE. § EXHAUST RISER. HANGING ANGLE. EQUIPMENT BY OTHERS. 80" 24" NOM. 48" SECTION VIEW - MODEL 4824ES-VHB HOOD - #5 SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . e c o n a i r . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NFP A WIT H IN S LI D TE R C U S MASTER DRAWING 3/4" = 1'-0" 6037327 3 JG 6/6/2023 Ea s t e r n L A & O r a n g e C t y M e c h 30 0 2 D o w A v e n u e , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 5 0 3 - 0 7 7 7 E M A I L : r e g 1 4 4 @ e c o n a i r . c o m Ta i e r R e s t a u r a n t - A r c a d i a Ar c a d i a , C A , 9 1 0 0 7 40 0 S o u t h B a l d w i n A v e n u e , S u i t e 2 3 1 ACTUAL DIMENSIONS 19-5/8" x 19-5/8" x 1-7/8" 19-5/8" x 15-5/8" x 1-7/8" 15-5/8" x 19-5/8" x 1-7/8" 15-5/8" x 15-5/8" x 1-7/8" FILTER INFORMATION Region 144 20 x 20 16 x 20 16 x 16 20 x 16 NOM. SIZE (H x W) 2.28 11 1.78 1.39 1.78 9.1 7.4 8.9 (SQ. FEET) FREE AREA (H x W x D)(LBS) WEIGHT SOUTHERN CALIFORNIA OFFICE TUSTIN, CA 92780 PHONE: (714) 503 - 0777 REG144@CAPTIVEAIRE.COM FOR QUESTIONS, CALL THE HANGING ANGLE THROUGH ANOTHER CONNECTED TO ROOF JOIST 1/2" DIA. ALL THREAD ROD AND WASHER - ONE ABOVE 1/2" DIA. HEAVY DUTY NUT AND ONE BELOW HANGING ANGLE ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR CORNER HANGING ANGLE DETAIL ND-2 HANGING ANGLE IS PRE-PUNCHED AT FACTORY STEEL HANGING ANGLE 3002 DOW AVE., SUITE 410 CAPTRATE R RCAPTIVEAIRE CAPTRATE & KLEEN-GARD FILTERS TE A ARE BUILT IN COMPLIANCE WITH INT. MECH. CODE (IMC) UL STANDARD #1046 NSF NSF STANDARD #2 O NFPA #96 CH B N RAN I ,OR M . YR OR LAIGNTSB AT UL 710 & ULC710 STANDARDS E.T.L. LISTED 102900319PRT-001 CAPTIVE-AIRE HOODS ARE BUILT IN COMPLIANCE WITH NFPA #96 ACTUAL DIMENSIONS 19-5/8" x 19-5/8" x 1-7/8" 19-5/8" x 15-5/8" x 1-7/8" 15-5/8" x 19-5/8" x 1-7/8" 15-5/8" x 15-5/8" x 1-7/8" 2.28 1.78 1.39 1.78 (SQ. FEET) FREE AREA (H x W x D)(LBS) WEIGHT 10 12 12 1520 x 20 16 x 20 16 x 16 20 x 16 NOM. SIZE (H x W) ACTUAL DIMENSIONS 19-5/8" x 19-5/8" x 1-7/8" 19-5/8" x 15-5/8" x 1-7/8" 15-5/8" x 19-5/8" x 1-7/8" 15-5/8" x 15-5/8" x 1-7/8" 2.23 1.73 1.35 1.73 (SQ. FEET) FREE AREA (H x W x D)(LBS) WEIGHT 20 x 20 16 x 20 16 x 16 20 x 16 NOM. SIZE (H x W) GREASE-STOP SOLO FILTER INFORMATION CAPTRATE R R GREASE-STOP COMBO FILTER INFORMATION KLEEN-GARD R SS BAFFLE TYPE 11 9.1 7.4 8.9 SLI DTE R ACCORDANCE No. 96 NFPA WITH BUILT IN WITH NFPA No. 96 IN ACCORDANCE BUILT SLI DTE R FIRE SYSTEM INFORMATION - JOB#6037327 1 2 TANK FS TANK FS 4.0/4.0/4.0/4.0 4.0 74 20 WALL UTILITY CABINET LEFT FIRE CABINET LEFT N/A LEFT, HOOD 3 FIRE SYSTEM NO TAG TYPE SIZE FLOW POINTS INSTALLATION SYSTEM LOCATION ON HOOD 12" ∅18" HOOD FRONT HOOD BACK HOOD # 1 (L) JOB # 6037327 FS # 1 MODEL: ND-2 SIZE: 54"x24" LENGTH: 12' 0" TA N K O V E R L A P P I N G PR O T E C T I O N - 3 0 HI G H P R O X I M I T Y 28 1 . 0 0 " L X 3 0 . 0 0 " D DUCT S 360 OL-F OL-F OL-F 25.00"25.00" 21.50" OL-F 21.50" OL-F 21.50" OL-F 21.50" OL-F 21.50" OL-F 21.50" OL-F 21.50" OL-F 21.50" OL-F 21.50" OL-F 21.50" OL-F NOZZLE HEIGHT 35-50" FROM COOKING SURFACE. (45.25") 18.00"28.56"28.56"28.56"28.56"11.78"16.78"28.56"28.56"28.56"28.56"12.00" SLPCON-03FT KIT SLPCON-10FT KIT 12.00" 48.00" 1 631 1 1 3 3 6 7 6 2 5 24.00" 48.00" 12" ∅18" HOOD FRONT HOOD BACK HOOD # 2 (R) JOB # 6037327 FS # 1 MODEL: ND-2 SIZE: 54"x24" LENGTH: 11' 11" DUCT S 360 OL-F OL-F OL-F SLPCON-30FT KIT TO HOOD# 1 WALL-UC ALTERNATE FIELD-CONNECTION POINT PL E N U M PL E N U M TO HOOD# 1 WALL-UC PL E N U M PL E N U M NOTES - FIELD PIPE DROPS AS SHOWN PIPING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS. - FIELD INSTALLED DROP: FACTORY WILL PROVIDE QTY 2 60IN LONG PIECES OF CHROME PLATED PIPING SHIPPED LOOSE TO BE FIELD-INSTALLED. - SHIP LOOSE DROP: FACTORY WILL PROVIDE THE EXACT CHROME PIPE LENGTH NEEDED SHIPPED LOOSE TO BE FIELD-INSTALLED. - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - OVERLAPPING COVERAGE SHALL NOT BE USED ON ANY APPLIANCE WITH AN OBSTRUCTION. - IF APPLICABLE, EXTENDED PRE-PIPED DROPS ARE SHIPPED LOOSE. - FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. - THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS. - OL-F NOZZLE PART NUMBER REPLACES 3070-3/8H-10-SS JOB #: 6037327. JOB NAME: TAIER RESTAURANT - ARCADIA. SYSTEM SIZE: TANK-SP-4-WC TOTAL FP REQUIRED: 74. HOOD # 1 12' 0.00" LONG x 54" WIDE x 24" HIGH. RISER # 1 SIZE: 18" DIA. HOOD # 1 METAL BLOW-OFF CAPS INCLUDED. HOOD # 2 11' 11.00" LONG x 54" WIDE x 24" HIGH. RISER # 1 SIZE: 18" DIA. HOOD # 2 METAL BLOW-OFF CAPS INCLUDED. - HEAVY-DUTY APPLIANCES (RATED 600°F) WILL REQUIRE AN ADDITIONAL DOWNSTREAM FIRESTAT IN THE EVENT THAT THE DUCTWORK CONTAINS ANY HORIZONTAL RUNS OVER 25 FT IN LENGTH. - MEDIUM TO LIGHT-DUTY APPLIANCES (RATED 450°F) WILL NOT REQUIRE ANY ADDITIONAL DOWNSTREAM DETECTION. PRESSURE SUPERVISION SWITCH. PRIMARY ACTUATOR RELEASE. 4 GALLON TANK. 7 6 5 4 2 1 LEGEND - FIRE CABINET TANK SYSTEM PRIMARY HOSE ASSEMBLY. SECONDARY ACTUATOR RELEASE.3 SECONDARY HOSE ASSEMBLY. REMOTE MANUAL ACTUATION DEVICE. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . e c o n a i r . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NFP A WIT H IN S LI D TE R C U S MASTER DRAWING 1/2" = 1'-0" 6037327 4 JG 6/6/2023 Ea s t e r n L A & O r a n g e C t y M e c h 30 0 2 D o w A v e n u e , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 5 0 3 - 0 7 7 7 E M A I L : r e g 1 4 4 @ e c o n a i r . c o m Ta i e r R e s t a u r a n t - A r c a d i a Ar c a d i a , C A , 9 1 0 0 7 40 0 S o u t h B a l d w i n A v e n u e , S u i t e 2 3 1 11" ∅14" HOOD FRONT HOOD BACK HOOD # 3 JOB # 6037327 FS # 2 MODEL: ND-2 SIZE: 54"x24" LENGTH: 7' 11" TA N K O V E R L A P P I N G PR O T E C T I O N - 3 6 HI G H P R O X I M I T Y 89 . 0 0 " L X 3 0 . 0 0 " D DUCT S 360 OL-F OL-F 25.00" 21.50" OL-F 21.50" OL-F 21.50" OL-F NOZZLE HEIGHT 35-50" FROM COOKING SURFACE. (45.25") 18.00"32.50"32.50"12.00" 7 1 2 5 PL E N U M NOTES - FIELD PIPE DROPS AS SHOWN PIPING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS. - FIELD INSTALLED DROP: FACTORY WILL PROVIDE QTY 2 60IN LONG PIECES OF CHROME PLATED PIPING SHIPPED LOOSE TO BE FIELD-INSTALLED. - SHIP LOOSE DROP: FACTORY WILL PROVIDE THE EXACT CHROME PIPE LENGTH NEEDED SHIPPED LOOSE TO BE FIELD-INSTALLED. - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - OVERLAPPING COVERAGE SHALL NOT BE USED ON ANY APPLIANCE WITH AN OBSTRUCTION. - IF APPLICABLE, EXTENDED PRE-PIPED DROPS ARE SHIPPED LOOSE. - FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. - THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS. - OL-F NOZZLE PART NUMBER REPLACES 3070-3/8H-10-SS JOB #: 6037327. JOB NAME: TAIER RESTAURANT - ARCADIA. SYSTEM SIZE: TANK-SP-1 TOTAL FP REQUIRED: 20. HOOD # 3 7' 11.00" LONG x 54" WIDE x 24" HIGH. RISER # 1 SIZE: 14" DIA. HOOD # 3 METAL BLOW-OFF CAPS INCLUDED. - HEAVY-DUTY APPLIANCES (RATED 600°F) WILL REQUIRE AN ADDITIONAL DOWNSTREAM FIRESTAT IN THE EVENT THAT THE DUCTWORK CONTAINS ANY HORIZONTAL RUNS OVER 25 FT IN LENGTH. - MEDIUM TO LIGHT-DUTY APPLIANCES (RATED 450°F) WILL NOT REQUIRE ANY ADDITIONAL DOWNSTREAM DETECTION. PRESSURE SUPERVISION SWITCH. PRIMARY ACTUATOR RELEASE. 4 GALLON TANK. 7 6 5 4 2 1 LEGEND - FIRE CABINET TANK SYSTEM PRIMARY HOSE ASSEMBLY. SECONDARY ACTUATOR RELEASE.3 SECONDARY HOSE ASSEMBLY. REMOTE MANUAL ACTUATION DEVICE. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . e c o n a i r . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NFP A WIT H IN S LI D TE R C U S MASTER DRAWING 1/2" = 1'-0" 6037327 5 JG 6/6/2023 Ea s t e r n L A & O r a n g e C t y M e c h 30 0 2 D o w A v e n u e , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 5 0 3 - 0 7 7 7 E M A I L : r e g 1 4 4 @ e c o n a i r . c o m Ta i e r R e s t a u r a n t - A r c a d i a Ar c a d i a , C A , 9 1 0 0 7 40 0 S o u t h B a l d w i n A v e n u e , S u i t e 2 3 1 FLOW. ELECTRIC GAS VALVE. STRAINER. 4" MIN. EXHAUST FAN INFORMATION - JOB#6037327 1 2 3 4 5 1 1 1 1 1 DU180HFA DU180HFA DU85HFA DU33HFA DU33HFA CAPTIVEAIRE CAPTIVEAIRE CAPTIVEAIRE CAPTIVEAIRE CAPTIVEAIRE 3600 3600 1800 800 600 1.250 1.250 0.750 0.400 0.400 1336 1336 1242 1463 1232 TEFC,PREMIUM TEFC,PREMIUM TEAO-ECM TEAO-ECM TEAO-ECM 3.000 3.000 0.750 0.333 0.333 1.8420 1.8420 0.3730 0.2090 0.1250 3 3 1 1 1 208 208 115 115 115 9.4 9.4 8.9 4.3 4.3 831 FPM 831 FPM 570 FPM 396 FPM 297 FPM 181 181 94 68 68 21.7 21.7 10.3 14.8 10.6 FAN UNIT NO TAG QTY FAN UNIT MODEL #MANUFACTURER CFM ESP RPM MOTOR ENCL HP BHP PHASE VOLT FLA DISCHARGE VELOCITY WEIGHT (LBS) SONES FAN OPTIONS 1 2 3 4 5 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 GREASE BOX FAN BASE CERAMIC SEAL - INSTALLED AT PLANT - FOR GREASE DUCTS 2 YEAR PARTS WARRANTY GREASE BOX FAN BASE CERAMIC SEAL - INSTALLED AT PLANT - FOR GREASE DUCTS 2 YEAR PARTS WARRANTY GREASE BOX FAN BASE CERAMIC SEAL - INSTALLED AT PLANT - FOR GREASE DUCTS ECM WIRING PACKAGE - PWM SIGNAL FROM ECPMO3 PREWIRE (TELCO MOTOR), CCW ROTATION 2 YEAR PARTS WARRANTY ECM WIRING PACKAGE - MANUAL OR 0-10VDC REFERENCE SPEED CONTROL -RTC- (TELCO MOTOR), CCW ROTATION I 15-BDD DAMPER 2 YEAR PARTS WARRANTY ECM WIRING PACKAGE - MANUAL OR 0-10VDC REFERENCE SPEED CONTROL -RTC- (TELCO MOTOR), CCW ROTATION I 15-BDD DAMPER 2 YEAR PARTS WARRANTY FAN UNIT NO TAG QTY DESCRIPTION FAN ACCESSORIES 1 2 3 4 5 YES YES YES YES YES FAN UNIT NO TAG EXHAUST GREASE CUP GRAVITY DAMPER WALL MOUNT SUPPLY SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT CURB ASSEMBLIES 1 2 3 4 5 # 1 # 2 # 3 # 4 # 5 41 LBS 41 LBS 36 LBS 18 LBS 18 LBS CURB CURB CURB CURB CURB 26.500"W X 26.500"L X 20.000"H ALONG LENGTH, RIGHT VENTED HINGED. 26.500"W X 26.500"L X 20.000"H ALONG LENGTH, RIGHT VENTED HINGED. 23.000"W X 23.000"L X 20.000"H ALONG LENGTH, RIGHT VENTED HINGED. 19.500"W X 19.500"L X 12.000"H ALONG LENGTH, RIGHT. 19.500"W X 19.500"L X 12.000"H ALONG LENGTH, RIGHT. NO ON FAN WEIGHT ITEM SIZE - VARIABLE SPEED CONTROL. - THERMAL OVERLOAD PROTECTION (SINGLE PHASE). - HIGH HEAT OPERATION 300°F (149°C). EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. NORMAL TEMPERATURE TEST 26" 28" 37 3/8" 16 1/2" 2" 22 5/8" - INTERNAL WIRING. - ROOF MOUNTED FANS. - RESTAURANT MODEL. FEATURES: - DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS). TOP VIEW 37 3/8" 28" - NEMA 3R SAFETY DISCONNECT SWITCH. 33 3/4" GREASE DRAIN. - GREASE CLASSIFICATION TESTING. - UL705 AND UL762 AND ULC-S645 ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600°F (316°C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. 26" 26" ROOF OPENING DIMENSIONS. 20" 26 1/2" 20 GAUGE CONSTRUCTION. STEEL 3" FLANGE. 26 1/2" HINGE KIT VENTED CURB. FANS #1, #2 - DU180HFA EXHAUST FAN OPTIONS - GREASE BOX. - FAN BASE CERAMIC SEAL - INSTALLED AT PLANT - FOR GREASE DUCTS. - 2 YEAR PARTS WARRANTY. OPEN POSITION 3 3/4 17 1/8 5 1/16 GREASE BOX. 3 APPROX. GREASE BOX INSTALLATION COVER. BOX GREASE GREASE PIPE. CURB. (OPTIONAL). KIT HINGE FAN. CLOSED POSITION INSTALL GREASE PIPE AS SHOWN ON PIC. 4. GREASE PIPE. GREASE BOX. STEP 3) PIC. 3 PIC. 4 COVER. GREASE BOX HOLD 3" DIMENSION AS SHOWN ON PIC. 1. SCREW GREASE BOX COVER TO CURB USING (3) LONG (3/4" LG.) ATTACH GREASE BOX COVER TO THE CURB, GREASE BOX FIELD INSTALLATION ATTACH GREASE BOX TO GREASE BOX COVER, SLIDE AND DROP. COVER. BOX GREASE PIC. 1 COVER. GREASE BOX 3 AS SHOWN ON PIC. 3. STEP 2) CURB. SCREWS AS SHOWN ON PIC. 2. PARTS INCLUDED GREASE BOX. GREASE PIPE. GREASE BOX COVER. SHEET METAL SCREWS 3 - LONG (3/4" LG.). STEP 1) CURB. PIC. 2 CURB. 08/19/02 GREASEBOX REV.#2 *NOTE: UL 705 INSTALL. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . e c o n a i r . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NFP A WIT H IN S LI D TE R C U S MASTER DRAWING 3/4" = 1'-0" 6037327 6 JG 6/6/2023 Ea s t e r n L A & O r a n g e C t y M e c h 30 0 2 D o w A v e n u e , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 5 0 3 - 0 7 7 7 E M A I L : r e g 1 4 4 @ e c o n a i r . c o m Ta i e r R e s t a u r a n t - A r c a d i a Ar c a d i a , C A , 9 1 0 0 7 40 0 S o u t h B a l d w i n A v e n u e , S u i t e 2 3 1 - VARIABLE SPEED CONTROL. - THERMAL OVERLOAD PROTECTION (SINGLE PHASE). - HIGH HEAT OPERATION 300°F (149°C). EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. NORMAL TEMPERATURE TEST 22 1/2" 24 3/4" 31 7/8" 14 7/8" 2" 23" - INTERNAL WIRING. - ROOF MOUNTED FANS. - RESTAURANT MODEL. FEATURES: - DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS). TOP VIEW 31 7/8" 24 3/4" - NEMA 3R SAFETY DISCONNECT SWITCH. 30 1/2" GREASE DRAIN. - GREASE CLASSIFICATION TESTING. - UL705 AND UL762 AND ULC-S645 ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600°F (316°C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. 22 1/2" 22 1/2" ROOF OPENING DIMENSIONS. 20" 23" 20 GAUGE CONSTRUCTION. STEEL 3" FLANGE. 23" HINGE KIT VENTED CURB. FAN #3 DU85HFA - EXHAUST FAN OPTIONS - GREASE BOX. - FAN BASE CERAMIC SEAL - INSTALLED AT PLANT - FOR GREASE DUCTS. - ECM WIRING PACKAGE - PWM SIGNAL FROM ECPMO3 PREWIRE (TELCO MOTOR), CCW ROTATION. - 2 YEAR PARTS WARRANTY. - THERMAL OVERLOAD PROTECTION (SINGLE PHASE). 16" 21" 25 1/2" 2" 12 1/8" 18 1/2" FEATURES: - INTERNAL WIRING. - VARIABLE SPEED CONTROL. - ROOF MOUNTED FANS. - UL705. - DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS). TOP VIEW 25 1/2" 21" - NEMA 3R SAFETY DISCONNECT SWITCH. 25 1/4" 3" FLANGE. 16" 16" ROOF OPENING DIMENSIONS. 20 GAUGE CONSTRUCTION. STEEL 12" 19 1/2" 19 1/2" CURB. (ROOF OPENING). 16 BACKDRAFT DAMPER INSTALLATION BACKDRAFT DAMPER. AIR FLOW FANS #4, #5 - DU33HFA EXHAUST FAN OPTIONS - ECM WIRING PACKAGE - MANUAL OR 0-10VDC REFERENCE SPEED CONTROL -RTC- (TELCO MOTOR), CCW ROTATION. - I 15-BDD DAMPER. - 2 YEAR PARTS WARRANTY. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . e c o n a i r . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NFP A WIT H IN S LI D TE R C U S MASTER DRAWING 3/4" = 1'-0" 6037327 7 JG 6/6/2023 Ea s t e r n L A & O r a n g e C t y M e c h 30 0 2 D o w A v e n u e , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 5 0 3 - 0 7 7 7 E M A I L : r e g 1 4 4 @ e c o n a i r . c o m Ta i e r R e s t a u r a n t - A r c a d i a Ar c a d i a , C A , 9 1 0 0 7 40 0 S o u t h B a l d w i n A v e n u e , S u i t e 2 3 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Label Description Location MT-01 Fan Motor [3] SW-01 Main disconnect switch [3] Component Identification 23 Installed Options RD - RED BL - BLUE WH - WHITE OR - ORANGE BR - BROWN BK - BLACK PK - PINK PR - PURPLE GY - GRAY GR - GREEN YW - YELLOW WIRE COLOR DENOTES FIELD WIRING DENOTES INTERNAL WIRING NOTES SW-01 BK BK MT-01 GR BK GR BK BK BK 5 6 3 4 1 2 GR EXHAUST 3HP-208V-3P-9.4FLA VFD PART: ESV222N02YXB571 MOTOR INFO ELECTRICAL INFORMATION MOTOR/CTRL MCA: 11.8A MOTOR/CTRL MOP: 20A DRAWING NUMBER JOB MODELSHIP DATE Exhaust Fan Wiring EXH6037327-1 6037327 - Taier Restaurant - Arcadia 6/6/2023 DU180HFA 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Label Description Location MT-01 Fan Motor [3] SW-01 Main disconnect switch [3] Component Identification 23 Installed Options RD - RED BL - BLUE WH - WHITE OR - ORANGE BR - BROWN BK - BLACK PK - PINK PR - PURPLE GY - GRAY GR - GREEN YW - YELLOW WIRE COLOR DENOTES FIELD WIRING DENOTES INTERNAL WIRING NOTES SW-01 BK BK MT-01 GR BK GR BK BK BK 5 6 3 4 1 2 GR EXHAUST 3HP-208V-3P-9.4FLA VFD PART: ESV222N02YXB571 MOTOR INFO ELECTRICAL INFORMATION MOTOR/CTRL MCA: 11.8A MOTOR/CTRL MOP: 20A DRAWING NUMBER JOB MODELSHIP DATE Exhaust Fan Wiring EXH6037327-2 6037327 - Taier Restaurant - Arcadia 6/6/2023 DU180HFA 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Label Description Location MT-01 Fan Motor [3] SW-01 Main disconnect switch [3] Component Identification 23 Installed Options RD - RED BL - BLUE WH - WHITE OR - ORANGE BR - BROWN BK - BLACK PK - PINK PR - PURPLE GY - GRAY GR - GREEN YW - YELLOW WIRE COLOR DENOTES FIELD WIRING DENOTES INTERNAL WIRING NOTES SW-01 BK MT-01 GR WH GR WH BK 3 4 1 2 WH *22 AWG WHITE MOTOR *22 AWG ROTATION WIRE. CONNECT TO 16 AWG MOTOR CONTROL RD YW PWM FROM ECPMO3 RD BK 16 AWG 16 AWG BLACK WIRE TO REVERSE ROTATION GR EXHAUST 0.75HP-115V-1P-8.9FLA MOTOR INFO ELECTRICAL INFORMATION MOTOR/CTRL MCA: 11.2A MOTOR/CTRL MOP: 20A DRAWING NUMBER JOB MODELSHIP DATE Exhaust Fan Wiring EXH6037327-3 6037327 - Taier Restaurant - Arcadia 6/6/2023 DU85HFA 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Label Description Location MT-01 Fan Motor [3] SW-01 Main disconnect switch [3] Component Identification 23 Installed Options RD - RED BL - BLUE WH - WHITE OR - ORANGE BR - BROWN BK - BLACK PK - PINK PR - PURPLE GY - GRAY GR - GREEN YW - YELLOW WIRE COLOR DENOTES FIELD WIRING DENOTES INTERNAL WIRING NOTES 24VAC 20VA Transformer RTC-FSC-1 TR-01 SC-01 [2] [1] SW-01 BK MT-01 GR WH GR WH BK 3 4 1 2 WH *22 AWG WHITE MOTOR 16 AWG *22 AWG ROTATION WIRE. CONNECT TO 16 AWG 16 AWG BLACK WIRE TO REVERSE ROTATION GR SC-01 TR-01 24V BK RD WH BK 0-10V GND CONTROL MOTOR 24 VAC RD BK P3 OPTIONAL 0-10VDC SPEED REFERENCE INPUT EXHAUST 0.333HP-115V-1P-4.3FLA MOTOR INFO ELECTRICAL INFORMATION MOTOR/CTRL MCA: 5.4A MOTOR/CTRL MOP: 15A DRAWING NUMBER JOB MODELSHIP DATE Exhaust Fan Wiring EXH6037327-4 6037327 - Taier Restaurant - Arcadia 6/6/2023 DU33HFA 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Label Description Location MT-01 Fan Motor [3] SW-01 Main disconnect switch [3] Component Identification 23 Installed Options RD - RED BL - BLUE WH - WHITE OR - ORANGE BR - BROWN BK - BLACK PK - PINK PR - PURPLE GY - GRAY GR - GREEN YW - YELLOW WIRE COLOR DENOTES FIELD WIRING DENOTES INTERNAL WIRING NOTES 24VAC 20VA Transformer RTC-FSC-1 TR-01 SC-01 [2] [1] SW-01 BK MT-01 GR WH GR WH BK 3 4 1 2 WH *22 AWG WHITE MOTOR 16 AWG *22 AWG ROTATION WIRE. CONNECT TO 16 AWG 16 AWG BLACK WIRE TO REVERSE ROTATION GR SC-01 TR-01 24V BK RD WH BK 0-10V GND CONTROL MOTOR 24 VAC RD BK P3 OPTIONAL 0-10VDC SPEED REFERENCE INPUT EXHAUST 0.333HP-115V-1P-4.3FLA MOTOR INFO ELECTRICAL INFORMATION MOTOR/CTRL MCA: 5.4A MOTOR/CTRL MOP: 15A DRAWING NUMBER JOB MODELSHIP DATE Exhaust Fan Wiring EXH6037327-5 6037327 - Taier Restaurant - Arcadia 6/6/2023 DU33HFA SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . e c o n a i r . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NFP A WIT H IN S LI D TE R C U S MASTER DRAWING 3/4" = 1'-0" 6037327 8 JG 6/6/2023 Ea s t e r n L A & O r a n g e C t y M e c h 30 0 2 D o w A v e n u e , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 5 0 3 - 0 7 7 7 E M A I L : r e g 1 4 4 @ e c o n a i r . c o m Ta i e r R e s t a u r a n t - A r c a d i a Ar c a d i a , C A , 9 1 0 0 7 40 0 S o u t h B a l d w i n A v e n u e , S u i t e 2 3 1 ELECTRICAL PACKAGE - JOB#6037327 1 2 SC-E200111MA SC-E100111MA UTILITY CABINET LEFT UTILITY CABINET LEFT UTILITY CABINET LEFT HOOD # 1 UTILITY CABINET LEFT HOOD # 3 1 LIGHT 1 FAN 1 LIGHT 1 FAN SMART CONTROLS THERMOSTATIC CONTROL W/ RELAY ON/OFF WITH SUPPLY SMART CONTROLS THERMOSTATIC CONTROL W/ RELAY ON/OFF WITH SUPPLY EXHAUST EXHAUST SUPPLY EXHAUST SUPPLY 3 3 1 1 1 3.000 3.000 1.000 0.750 0.333 208 208 115 115 115 9.4 9.4 12.6 8.9 5.8 NO TAG PACKAGE #LOCATION SWITCHES LOCATION QUANTITY OPTION FANS CONTROLLED TYPE ɸ HP VOLT FLA DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 6037327 Taier Restaurant - Arcadia SC-E200111MA 6/6/2023 INSTALL ECP #1-1 Mixed Voltage w/ control for 2 3Ph Exhaust Fans, 1 120V 1Ph Supply Fan, Exhaust on in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. BREAKER PANEL TO PRIMARY CONTROL PANEL Responsibility: Electrician BREAKER PANEL PRIMARY CONTROL PANEL BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED BREAKER 1PH CONTROL POWER. DO NOT WIRE TO GFCI OR SHUNT TRIP BREAKER. Hot Neutral H1 N1 120 V 15 A Ground GND 1ST HOOD LIGHT BREAKER SHARED W/ CONTROL POWER. SWITCH #1 WIRE TO VFD QUICK CONNECTOR BREAKER 3PH MCA: MOCP: LINE LINE Ground EXH-1 SM-1 GND L1 L2 LINE L3 208 V 11.8 A 20 A WIRE TO VFD QUICK CONNECTOR BREAKER 3PH MCA: MOCP: LINE LINE Ground EXH-2 SM-2 GND L4 L5 LINE L6 208 V 11.8 A 20 A BREAKER 1PH MCA: MOCP: Hot Neutral L7 FN7 GND Ground SUP-6 115 V 15.8 A 25 A CONTROL PANEL TO FANS Responsibility: Electrician PRIMARY PANEL FANS Load Wiring WIRE TO VFD QUICK WIRE TO DISCONNECT CONNECTOR MUST HAVE ITS OWN CONDUIT DO NOT SHARE CONDUIT! FLA: HP: VOLT: EXH-101 LOAD LEG 1 LOAD LEG 2 GND GROUND FAN: SM-1 LOAD LEG 3 U1 V1 W1 9.4 3.000 208 V Load Wiring WIRE TO VFD QUICK WIRE TO DISCONNECT CONNECTOR MUST HAVE ITS OWN CONDUIT DO NOT SHARE CONDUIT! FLA: HP: VOLT: EXH-202 LOAD LEG 1 LOAD LEG 2 GND GROUND FAN: SM-2 LOAD LEG 3 U2 V2 W2 9.4 3.000 208 V Load Wiring WIRE DIRECT TO STARTER BLACK WHITE GREEN WIRE TO FACTORY PROVIDED CONDUIT DROP FLA: HP: VOLT: T1 T2 LEG 1 / HOT LEG 2 / NEUTRAL GND GROUND C-1 SUP-6 06FAN: 12.6 1.000 115 V CONTROL PANEL TO ACCESSORY ITEMS Responsibility: Electrician CONTROL PANEL COMPONENT ALL SWITCHES FACTORY WIRED CAT-5 CONNECTION CONTROL PANEL SWITCHES TO J4 CONTROL PANEL HOOD LIGHTS TO 1400 W MAX WIRE TO J-BOX ON TOP OF HOOD B1 W1 GND BLACK WHITE GREEN HOOD LIGHTS 1 WIRE TO CONTROL BOARD. INSTALL SENSOR IN ROOM AWAY FROM HEAT SOURCES. DO NOT INSTALL SENSOR CONTROL PANEL KITCHEN TEMP TO SENSOR ON THE CEILING GRID, SEE MANUAL. T1A T1B ROOM TEMP FACTORY WIRED TEMPERATURE SENSOR. MOUNTED IN EXHAUST DUCT CONTROL PANEL DUCT SENSOR TO T2A T2B HOOD 1 RISER 1 WIRE TO CONTROL BOARD. SENSOR MOUNTED IN EXHAUST DUCT CONTROL PANEL DUCT SENSOR TO T3A T3B HOOD 2 RISER 1 CONTROL PANEL GAS VALVE TO 120V ONLY ONLY ENERGIZED THROUGH LCD HMI WHEN FIRE SYSTEM ARMED. GAS N1 HOT TO GAS VALVE NEUTRAL GAS SOLENOID THE FOLLOWING CONNECTIONS MAY OR MAY NOT BE REQUIRED BASED ON JOBSITE SPECIFICATIONS CONTROL PANEL EXTERNAL SIGNAL FOR SHUNT TRIP ST TERMINAL IS ENERGIZED IN FIRE CONDITION. CONTROL PANEL EXTERNAL SIGNAL FOR CONTACTOR COIL KS TERMINAL IS DE-ENERGIZED IN FIRE CONDITION. ST N1 NEUTRAL FROM SHUNT COIL HOT TO SHUNT COIL SHUNT COIL KS N1 NEUTRAL_TO_CONTACTOR_COIL HOT_TO_CONTACTOR_COIL CONTACTOR_COIL SPARE CONTACTS WILL MAKE CONTROL PANEL ON/OFF WITH DRY CONTACT SUPPLY FAN COMMON TO NORMALLY OPEN WHEN SUPPLY FAN IS ON. GROUP 1 SFC1 SFO1 COMMON NORMALLY OPEN SFC2 SFO2 COMMON NORMALLY OPEN CONTROL PANEL EXTERNAL TO SWITCH SIGNAL SWITCH THROUGH BMS WILL ACTIVATE ZONE1 FANS AND LIGHTS H1 IO1 BMS SWITCH C NO CONTROL PANEL GAS VALVE TO 24V DC ONLY ONLY ENERGIZED THROUGH LCD HMI WHEN FIRE SYSTEM ARMED. (NOT NEEDED IF USING 120V GAS VALVE). LGV N1D POSITIVE TO GAS VALVE NEGATIVE GAS SOLENOID CONTROL PANEL TO FIRE SYSTEM Responsibility: ALARM CONTRACTOR CONTROL PANEL COMPONENT CONTROL PANEL BUILDING SIGNAL FOR FIRE ALARM PANEL AL1 AL2 J9 BUILDING ALARM PANEL FIRE INPUT WIRE DIRECTLY TO CORE CIRCUIT BOARD. AL1 WILL MAKE AL2 IN FIRE CONDITION. CONTROL PANEL BUILDING SIGNAL FOR TROUBLE TROUBLE RELAY CONTACTS WILL MAKE TBC TO TBL IN TROUBLE CONDITION. BUILDING ALARM PANEL ALARM TBC TBL COMMON NORMALLY CLOSED CONTROL PANEL TO FIRE SYSTEM Responsibility: CERTIFIED INSTALLER CONTROL PANEL COMPONENT 21 22 FS-01 BK WH Fire Stat CONTROL PANEL MOUNTED FIRE TO DUCT DETECTION STAT(S) FIRE STAT SUPERVISED LOOP May be mixed factory and field wiring. See Installation Schematic. Multiple fire sensors possible. HIGH TEMP WIRE (842 F), PN: SLPCON-xFT required for all Supervised Loop wiring in contact with a hood. All other wiring shall be PN: 6320UL, Belden or similar. 23 24 FS-02 BK WH Fire Stat FIRE STATS DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 6037327 Taier Restaurant - Arcadia SC-E200111MA 6/6/2023 INSTALL ECP #1-2 Mixed Voltage w/ control for 2 3Ph Exhaust Fans, 1 120V 1Ph Supply Fan, Exhaust on in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. CONTROL PANEL SYSTEM PULL TO FIRE STATION MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM LOOP. Multiple manual actuation possible. Multiple manual actuation possible. A Plug jumper with wires from pin1 to pin4 and from pin2 to pin3 is mounted on J10, remove the jumpers and wire in the supervised actuation loop. Microswitch MS-01 is optional for fire system interlock. Auxiliary Interlock (AUX-01): Wire AU1 / AU2 of adjacent Master FS panel(s) in each manual activation loop for simultaneous activation. See Fire system drawings for more information. 101 102 103 104 AUX-01 AU1 AU2 PULL STATION MS-01 C NO Micro SW MAD-01 C NO Manual Actuation Device Adjacent FS Panel WIRE DIRECTLY TO CONTROL BOARD CAT-5 CONNECTIONCONTROL PANEL REMOTE FS TO MASTER PANEL EOL120A CORE PCB ECPM03 PLACE END OF LINE PLUG IN EMPTY JACK. PN: EOL120A ADDITIONAL DEVICES MAY BE INLINE. UNLESS VFD, PCU, OR OTHER COMPONENT IN SERIES. J3 J5 J6 CONTROL PANEL MASTER FS TO PANEL WIRE TO LIKE TERMINALS IN ALL CORE PANELS THAT MUST ACTIVATE TOGETHER. SET MASTER & SLAVE DIP SWITCHES PER FIRE SYSTEM SHIELDED TWISTED PAIR INTERLOCK NETWORK MASTER CORE MANUAL. CA CB CC BLACK RED SHIELD CA CB CC WALL MOUNT UTILITY CABINET CAS ELECTRIC WET CHEMICAL PROTECTION ELECTRICAL DETAIL 02/11/2021 Rev. 02 ELECTRICIAN: 1. WIRE MAIN CONTROL PANEL PER INCLUDED SCHEMATIC 2. WIRE ALL FANS PER INCLUDED SCHEMATIC 3. WIRE SHUNT TRIP BREAKER (OPTIONAL) 4. WIRE UDS APPLIANCE KILL SWITCH, IF EQUIPPED (OPTIONAL) 5. WIRE GAS VALVE NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS EXHAUST HOOD 36 INCHES CLEARANCE REQUIRED IN FRONT OF ALL UTILITY CABINET DOORS THE PANEL SHALL ALSO BE LOCATED IN AN ACCESSIBLE AREA WHERE THE AUDIBLE AND VISUAL ALARMS CAN BE HEARD AND SEEN GAS ELECTRIC ELECTRICAL CONTRACTOR REQUIREMENT ITEM CONNECTION IN PANEL CONNECTION IN DEVICE VOLTAGE AMPERAGE COMMENTS SHUNT TRIP BREAKER (OPTIONAL)ST & N1 BREAKER COIL (A1 & A2) 120 VAC < 4 AMPS ST TO A1 ON SHUNT BREAKER COIL, AND NEUTRAL TO A2 ON SHUNT TRIP BREAKER COIL CONTROL PANEL POWER H1 & N1 + GROUND CIRCUIT BREAKER 120 VAC 15 AMPS CONTROL PANEL POWER MUST NOT BE RUN THROUGH SHUNT TRIP BREAKER UDS APPLIANCE KILL SWITCH (OPTIONAL)KTS & N1 KTS & N1 120 VAC < 4 AMPS KILL SWITCH TERMINALS MUST BE IN SERIES WITH OTHER KILL SWITCHES REMOTE 120VAC ANSUL AUTOMAN (OPTIONAL)AU1, AU2 SOLENOID 120 VAC < 6 AMPS 120V TO AU1, AU2 TO ANSUL ELECTRIC AUTOMAN, ANSUL SOLENOID TO NEUTRAL GAS VALVE LGV & N1D (IF 24 VDC) GAS & N1 (IF 120 VAC) RED/RED/GREEN 24 VDC OR 120 VAC < 1.0 AMPS IF 24 VDC - 2 WIRES & GROUND, N1D TO RED, LGV TO RED, AND GREEN TO GROUND IF 120 VAC - 2 WIRES & GROUND GAS TO RED, N1 TO RED, AND GREEN TO GROUND SHUNT TRIP BREAKER (OPTIONAL) -2 WIRES, 120VAC -ST TO A1 ON SHUNT BREAKER -NEUTRAL TO A2 ON SHUNT TRIP BREAKER POWER TO ELECTRIC APPLIANCE CONTROL PANEL POWER -2 WIRES & GROUND -120 VAC, 15 AMP SERVICE -WIRE TO H1 AND N1, GROUND -POWER MUST NOT ORIGINATE FROM SHUNT TRIP BREAKER GAS VALVE POWER -2 WIRES & GROUND -24 VDC WIRE TO LGV & N1D -120 VAC WIRE TO GAS &N1 GAS VALVE -STRAINER MUST BE INSTALLED UPSTREAM OF VALVE COOKING APPLIANCE(S) DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 6037327 Taier Restaurant - Arcadia SC-E200111MA 6/6/2023 INSTALL ECP #1-3 Fire System #1 TANK FS - 4.0/4.0/4.0/4.0. FS-1: MASTER WALL MOUNT UTILITY CABINET CAS ELECTRIC WET CHEMICAL PROTECTION LOW-VOLTAGE DETAIL 02/05/2018 Rev. 1 ALARM CONTRACTOR: 1. WIRE MANUAL ACTUATION DEVICE(S), REMOTE FIRESTAT(S), CORE INTERLOCK(S), FIRE SENSOR(S) AND FIRE ALARM CONTACTS 2. COMPLETE FINAL HOOKUP OF SYSTEM 3. VERIFY FINAL FIRE SYSTEM TEST ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES 36 INCHES CLEARANCE REQUIRED IN FRONT OF ALL UTILITY CABINET DOORS THE PANEL SHALL ALSO BE LOCATED IN AN ACCESSIBLE AREA WHERE THE AUDIBLE AND VISUAL ALARMS CAN BE HEARD AND SEEN EXHAUST HOOD ELECTRIC GAS NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS ALARM CONTRACTOR REQUIREMENT ITEM CONNECTION IN PANEL CONNECTION ON DEVICE VOLTAGE AMPERAGE COMMENTS MANUAL ACTUATION DEVICE(S) 101 AND 104 102 AND 103 1 & 2 24 VDC < 1.0 AMPS WIRE MANUAL ACTUATION DEVICE TERMINAL 1 BETWEEN CORE PANEL TERMINALS 102 AND 103 WIRE MANUAL ACTUATION DEVICE TERMINAL 2 BETWEEN CORE PANEL TERMINALS 101 AND 104 JUMPER 101 TO 104 AND 102 TO 103 IF NO MANUAL ACTUATION DEVICE IS INSTALLED MANUAL ACTUATION DEVICE COVER N/A N/A N/A N/A MANUAL ACTUATION DEVICE COVER MUST BE INSTALLED IF SURFACE MOUNTED, USE COVER EXTENSION STI-6531B REMOTE FIRESTAT SENSOR(S) 21 AND 24 22 AND 23 BLACK AND WHITE 24 VDC < 1.0 AMPS WIRE FIRE SENSOR WHITE WIRES BETWEEN HOOD CORE PANEL TERMINALS 22 AND 23 WIRE FIRE SENSOR BLACK WIRE BETWEEN HOOD CORE PANEL TERMINALS 21 AND 24 HIGH TEMP (842°F) #CW04427 (WHT) & #CW04427B (BLK)WIRE OR SIMILAR ONLY IF RAN OVER TOP OF HOOD; OTHERWISE BELDEN #6320UL OR SIMILAR PLENUM RATED WIRE; SEE FIGURE 1 FIRE ALARM CONTACT AL1, AL2 VARIES 50V MAX (AC/DC) UP TO 1 AMP FIRE ALARM RELAY CONTACTS FOR BUILDING FIRE ALARM LOCATED IN THE CORE ELECTRICAL CONTROL PANEL CORE INTERLOCK(S)ILA, ILB, ILC ILA, ILB, ILC RS-485 COMMUNICATIONS SIGNAL CORE SYSTEM (1) ILA, TO CORE SYSTEM (2) ILA. CORE SYSTEM (1) ILB, TO CORE SYSTEM (2) ILB. CORE SYSTEM (1) ILC, TO CORE SYSTEM (2) ILC. USE BELDEN# 88760 OR SIMILAR WIRE TROUBLE CONTACT TBC, TBL, TOK VARIES MAX 120 VAC UP TO 6 AMPS WIRE TO TBL & TBC NORMALLY OPEN CONTACT, CLOSES IN TROUBLE CONDITION CORE COMMUNICATIONS CABLE RJ-45 Jack INTERNET CONNECTION SIGNAL <1.0 AMPS TYPICAL CONNECTION CAT5 CABLE TO LOCAL AREA NETWORK VIA ETHERNET SWITCH OR WIRELESS ROUTER WITH VALID INTERNET CONNECTION 42 TO 48 INCHES ABOVE FLOOR LEVEL TO CENTER OF PUSH STATION MANUAL ACTUATION DEVICE 10 TO 20 FEET FROM HOOD LOCATED NEAR POINT OF EGRESS FROM HOOD MANUAL ACTUATION DEVICE WIRES -4 WIRES, 24VDC WIRE (TERMINAL 1) BETWEEN 102 AND 103 -WIRE (TERMINAL 2) BETWEEN 101 AND 104 -ADDITIONAL PULL STATIONS WIRED IN SUPERVISED LOOP -USE BELDEN #6320UL OR SIMILAR WIRE -SEE FIGURE 2 MANUAL ACTUATION DEVICE PART #STI-SS2431 PROTECTIVE COVER MUST BE INSTALLED SUPERVISED LOOP -4 WIRES, 24VDC CONNECT BLACK WIRES BETWEEN 21 AND 24 IN PANEL, CONNECT WHITE (OR RED) WIRES BETWEEN 22 AND 23 IN PANEL -ADDITIONAL FIRESTATS, WIRED IN SUPERVISED LOOP -USE HIGH TEMP (842°F) #CW04427 (WHT) & #CW04227B (BLK)WIRE ONLY IF RAN OVER TOP OF HOOD; OTHERWISE BELDEN #6320UL OR SIMILAR PLENUM RATED WIRE -SEE FIGURE 1 CORE COMMUNICATIONS CABLE -CAT5 CABLE MUST BE INSTALLED TO A LOCAL AREA NETWORK WITH VALID INTERNET ACCESS VIA ETHERNET SWITCH OR WIRELESS ROUTER CORE INTERLOCK -2 WIRES + SHIELD -USE BELDEN#88760 OR SIMILAR WIRE -SEE FIGURE 3 FIRE ALARM PANEL FIRE ALARM CONTACT -2 WIRES WIRED TO NORMALLY OPEN CONTACTS (CLOSES IN FIRE CONDITION) -CORE CONTROL PANEL AL1 AND AL2 -SEE FIGURE 2 TROUBLE CONTACT -2 WIRES TO NORMALLY OPEN CONTACTS (CLOSE IN TROUBLE CONDITION) -CORE PANEL TERMINALS TBL AND TBC -SEE FIGURE 4 COOKING APPLIANCE(S) DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 6037327 Taier Restaurant - Arcadia SC-E200111MA 6/6/2023 INSTALL ECP #1-4 Fire System #1 TANK FS - 4.0/4.0/4.0/4.0. FS-1: MASTER SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . e c o n a i r . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NFP A WIT H IN S LI D TE R C U S MASTER DRAWING 3/4" = 1'-0" 6037327 9 JG 6/6/2023 Ea s t e r n L A & O r a n g e C t y M e c h 30 0 2 D o w A v e n u e , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 5 0 3 - 0 7 7 7 E M A I L : r e g 1 4 4 @ e c o n a i r . c o m Ta i e r R e s t a u r a n t - A r c a d i a Ar c a d i a , C A , 9 1 0 0 7 40 0 S o u t h B a l d w i n A v e n u e , S u i t e 2 3 1 ROOM TEMPERATURE Provides room override based on temperature differential between the room and duct. Installed by electrician on a wall, 5'-6' off the finished floor, in the space but not directly under the hood or close to an appliance (including the electrical control box) so the reading is accurate for space. FANSLIGHTS SENSOR DUCT TEMPERATURE Provides exhaust air temperature for proper hood control operation. For all installations excluding a single hood with factory risers and a hood mounted panel, duct mounted temperature sensors will need to be field wired. 2-wire 18 AWG plenum rated thermistor cable must be used. SENSOR HOOD CONTROL The LCD interface provides user control and hood status. The faceplate is connected to the hood control panel through CAT-5 cable. A faceplate has 2 RJ-45 connectors. One connects to port J4 or J5 in the hood control panel and the other will typically be occupied by a RJ-45 end-of-line terminator. INTERFACE WALL MOUNTED CAS ELECTRIC WET CHEMICAL 02/05/2015 Rev. 16 AL1 AL2 END OF LINE DEVICE WIRING CONNECTIONS FOR FIRE ALARM CONTACT FIGURE 2 CORE CONTROL PANEL FIRE ALARM CONTACT ALARM INPUT BUILDING FIRE ALARM SHIELDED TWISTED PAIR ILA ILC ILB ILA BK ILB RD BK RD WIRING CONNECTIONS FOR CORE INTERLOCK FIGURE 3 ILC ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES SUPERVISION SWITCH 1 2 C BUILDING FIRE ALARM TROUBLE INPUT CORE CONTROL PANEL TROUBLE CONTACT NO C NC 1 C 2 SUPERVISION SWITCH SUPERVISION SWITCH END OF LINE DEVICETBC TBLTOK WIRING CONNECTIONS FOR TROUBLE CONTACT FIGURE 4 BK-C BK-C 21 22 23 24 J2-1 J2-2 J2-4 J2-3 21 BK-C 101 102 103 104 J10-1 J10-2 J10-4 J10-3 21 BK-C WIRING CONNECTIONS FOR FIRESTAT LOOP FIGURE 1 WIRING CONNECTIONS FOR MANUAL ACTUATION LOOP FIGURE 1A BREAK WIRE BEFORE INSERTING INTO TERMINALS FIRE STAT-2 FIRE STAT-1 NO-WH (OR RD) NO-WH (OR RD) BREAK WIRE BEFORE INSERTING INTO TERMINALS NO-WH (OR RD) MANUAL ACTUATION DEVICE NO-WH (OR RD) MANUAL ACTUATION DEVICE MICROSWITCH/ NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS USE BELDEN #6320UL OR SIMILAR WIRE DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 PROTECTION LOW-VOLTAGE FIGURES FS-1: MASTER WH BK A B C D E F G H I 1 2 3 4 5 6 7 8 9 10 FACTORY WIRING SCHEMATIC CIRCUIT BOARDS MOTOR POWER CIRCUIT PANEL LID COMPONENT LIST LABEL DESCRIPTION ST-X varies Starter OL-X varies Overload C-X varies Contactor TS-x A/CP-PO-T4"-EXPL Duct Thermostat 120 VAC RELAY NO COM COIL NC 34 6 5 8 2 7 1 RA-x 24 VDC RELAY RD-x NO COM COIL NC 34 6 5 8 2 7 1 PS-1 MDP18-24A-1C Power Sup. 24VDC BK RA-x 34.110.0184.0 120V Relay DPDT WH RA-x 34.110.0184.0 120V Relay DPDT GR UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG. N1 H1 DC - GN D DC + 8H1 7PCU 6ST 5KS 4KTS 3GAS 2AR1 1N1 120VJ9 5OV1 4SF1 3EF1 2B1 1IO1 120VJ7 AR1 H1 2x N1 2x B1 EF1 SF1 BK IO1 N1 BK BK BK JUMPER W1 BK 14AWG BK 64 RD-1 BL PR DC+RO1 RD-x 34.110.0188.0 24VDC Light Relay BK WH SF1 7 8RA-2 A1 A2C-1 8 7RD-1 24V 1 2 3 4 5 6 7 8 9 10 11121314 J6 N1 ON/OFF WITH SUP N1 RO 1 NH FAN PANEL COOLING DRY CONTACTS (SHOWN DE-ENERGIZED) HOOD LIGHTS J3 ECPM03/DAISY CHAIN AR1 H1 JUMPER FIRE SYSTEM BK BK BK GAS KS ST NOTE: Configure ECPM03 for CORE SM-1 SM-2 ECPM03 J10 IL 1 A IL 1 B JUMPER MAKE UP AIR INTERLOCK. 1 2 11 1 JUMPER 1 2 11 1 JUMPER NOTE: All items on ECPM03 J3 line to be daisy chained from one component to the next, with EOL120A at end of line. Place PN: EOL120A in empty RJ45 port. J3 ECPM03 or Previous EOL J5 MASTER CORE C RA-2-1 NO SFC1 SFO1 14 AWG YW C RA-2-2 NO SFC2 SFO2 14 AWG YW 20 x 18 x 8.62 BOX CONTROL INPUT 120V H1=LINE, N1=NEUTRAL, 15A BREAKER. DO NOT CONNECT TO SHUNT TRIP BREAKER. SEE INSTALLATION SCHEMATIC FOR ADDITIONAL REQ. LEGEND FIELD WIRING FACTORY WIRING BK- BLACK BL- BLUE BR- BROWN OR- ORANGE WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/GN STRIPE WH/BL- WH/BL STRIPE YW- YELLOW GY- GREY PR- PURPLE RD- RED GR- GREEN WH / B L BL H1N1 DC - DC + LN -+ PS-01 AC 24V GN D DC KSKS BK KS BK BK GAS ST BK EF1 PR WH GR / Y W WH / B L BL J4 J5 NH FAN SECONDARY PANEL COOLING IF NECESSARY EF1 WHBK JUMPER ECPM03 J10 IL 2 A IL 2 B TERMINAL GAS USED FOR 120V POWERED GAS VALVES ONLY DWG NO JOB NO DATE DRAWN BY JOB NAME DESCRIPTION OF OPERATION TYPE DRAWING TITLE 6037327 Taier Restaurant... FACTORY SC-E200111MA 6/6/2023 ECP #1-6 Mixed Voltage w/ control for 2 3Ph Exhaust Fans, 1 120V 1Ph Supply Fan, Exhaust on in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. BK BK BK BK BK BK BK BK BK BK BK BK U/T1 V/T2 W/T3 L1 L2 L3/N GR GR GND VFD: HP: MTR: FLA: P107: P108: P410: P150: P100: P194: P101: P131: P167: P103: P102: L1 L2 L3 14 AWG 3 PH 20 A 208 V U1 V1 W1 SM-1 ESV222N02YXB571 225 01 01 11 97 00 9.4 3.000 EXH-1 N/A N/A 52.4 49.0 0.0 GND BK BK BK BK BK BK BK BK BK BK BK BK U/T1 V/T2 W/T3 L1 L2 L3/N GR GR GND VFD: HP: MTR: FLA: P107: P108: P410: P150: P100: P194: P101: P131: P167: P103: P102: L4 L5 L6 14 AWG 3 PH 20 A 208 V U2 V2 W2 SM-2 ESV222N02YXB571 225 01 01 12 97 00 9.4 3.000 EXH-2 N/A N/A 52.4 49.0 0.0 GND BK WH T1 T2 T3 L1 L2 L3 1413 CONT: FLA: MTR: HP: L7 FN7 C-112 AWG 1 PH 25 A 115 V SUP-6 100-C16D10 12.6 1.000 A B C D E F G H I 1 2 3 4 5 6 7 8 9 10 FACTORY WIRING SCHEMATIC CORE FIRE PROTECTION COMPONENT LIST LABEL DESCRIPTION 120 VAC RELAY NO COM COIL NC 34 6 5 8 2 7 1 RA-x 24 VDC RELAY RD-x NO COM COIL NC 34 6 5 8 2 7 1 24 VOLT BATTERY PACK 5 AMP FUSE RD SHIELDED TWISTED PAIR PCB-2 J3-2 J4-1 J3-11 J4-3 J4-2 J4-8 J4-9 J4-12 J3-14 J4-5 J3-13 J3-4 J4-6 J3-10 J2-1 J2-2 J2-3 J2-4 J7-2 J7-3 J7-1 J3-1 J3-3 RD RD BR RD ALL 18AWG RD BK ORRD PKRD BRRD RD OR/BL BK 18AWG BK BK J3-5 J1-1 J1-2 RD BK BK RD FIRE STAT SUPERVISED LOOP May be mixed factory and field wiring. See Installation Schematic. Multiple fire sensors possible. + + RD BK BK RD Shield BK RD RS-485 CORE INTERLOCK NETWORK. Connection to other CORE Panels or Communication Module. See Installation Schematic for Connection. N1D 3xH1D3x DISCONNECT J1 21 22 23 24 16AWG WH N1 H1 PN: 1606-XLP-60EQ Adjust power supply to 27.5 Volts with an accurate Digital Volt Meter or with an HMI plugged into the CORE board. NL +- PSM-2 60W GR BK GND PCB-2 PCBCORE-APP CORE PCB PSM-2 1606-XLP-50E CORE POWER SUPPLY WS-x varies Water Solenoid LT-06 PNL-1163-0UR 24V Red Ind. Light LL-01 AQ5510 Surf. Level Sensor AA-01 SCE120LA3FP1B Audible Alarm PB-01 D7-F2X11 Prime/Reset Switch SW-04 BZ-2RQ1-A2 Tamper Switch SP-1 50000-805 Surfactant Pump PB-01 Prime / Reset A2A1 RD-20 Trouble Relay A2A1 RD-17 Fire Relay DRY CONTACTS (SHOWN DE-ENGERGIZED) AA-01 Audible Alarm SW-04 Door Tamper Switch C NO FS-01 BK WH Fire Stat FS-02 BK WH Fire Stat HIGH TEMP WIRE (842 F), PN: SLPCON-xFT required for all Supervised Loop wiring in contact with a hood. All other wiring shall be PN: 6320UL, Belden or similar. Factory mounted hood sensors will be terminated at junction box on top of hood. GV-1 varies 24v DC Gas Valve INTERLOCK FOR AUTOMAN ACTIVATION. Used for activating 120V automan or adjacent Master CORE panels during active Fire Condition.11 RD-18-1 14 YW J3-16 J3-8 BR 38 LT-6 R FIRE INDICATOR DIP Switch ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES. RD/GNRD A2A1 RD-19 Equipment Relay COOKING EQUIPMENT DISABLE RELAY. For UDS Kill Switch, wire EKC and EKS terminals to like terminals in UDS panel. 12 11 RD-19-1 14 EKC EST EKS YW INTERLOCK FOR AUTOMAN ACTIVATION. Used for activating 120V automan or adjacent Master CORE panels during active Fire Condition.11 RD-18-1 14 YW RD OR/BL A2A1 RD-18 Auxiliary Interlock Relay FS-XX 12-F28021-000360 Duct Fire Sensor LT-05 PNL-1163-0UY 24V YLW Ind. Light PS-01 Station STI-SS2431 Remote Puill/Push FOR SHIPMENT J10-1 J10-2 J10-3 J10-4 RD BK BK RD 101 102 103 104 MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM LOOP. Multiple manual actuation possible. A Plug jumper with wires from pin1 to pin4 and from pin2 to pin3 should be mounted on J10 if there is no manual actuation device and no microswitch. Jumper if water valve supervision switch is used MAD-01 C NO Manual Actuation Device MS-01 C NO Micro SW 1 2 3 4 5 6 7 8 SW 1 OPEN PUT END OF LINE PLUG IN EMPTY RJ45 J3 ECPM03 UNLESS PCU AFM OR OTHER COMPONENT IN SERIES. CAT-5 WIRING (MASTER ONLY) FIELD WIRED IF REMOTE PREWIRE RD-XX PLC-RPT-24DC/21 24VDC Phoenix Relay AUX-01 AU1 AU2 Auxiliary Interlock (AUX-01): Wire AU1 / AU2 of adjacent Master CORE panel(s) in each manual activation loop for simultaneous activation. AU1/AU2 will have continuity for 10 seconds if adjacent panel goes into fire condition, activating this CORE Panel but allowing for a reset after 10 seconds. NOTE: AU1/AU2 terminals of CORE Panel should not be wired into its own manual activation loop. Adjacent CORE Panel Master CORE set DIP SW 8 to CLOSED position. Slave CORE with address 1 set DIP SW 8 to CLOSED position. All other CORES set DIP SW 8 OPEN. 18AWG LEGEND FIELD WIRING FACTORY WIRING BK- BLACK BL- BLUE BR- BROWN OR- ORANGE WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/GN STRIPE WH/BL- WH/BL STRIPE YW- YELLOW GY- GREY PR- PURPLE RD- RED GR- GREEN FIRE INDICATOR FAULT CONDITION FLASH CODES 2 Release Solenoid 3 Pressure Switch 4 Auxiliary Fault 5 Microcontroller Fault 6 N/A 7 Supervised Loop 8 Ground Fault 9 Surfactant Low 10 Battery Voltage Low 11 AC Power Failure 12 Door Tamper Switch 13 Test Mode 14 CORE Interlock Network 15 Fault on Hood in Interlock Network 16 Fault on PCU in Interlock Network FIRE ALARM SYSTEM DRY CONTACTS. Termials AL1 & AL2 make in FIRE. To Building Fire Alarm Panel J9 AL1 AL2 J3-7 FIRE SYSTEM DRY CONTACTS. Dry contacts will make C2 to AR2 when system is armed. 12 11 RD-17-1 C2 AR2 14 AWG YW TROUBLE RELAY. Contact terminals TBC & TBL make if there is trouble. Contact terminals TBC & TOK make if the system is ok. 12 11 RD-20-1 14 TBC TBL TOK YW RD PS OR J4-9 PS EWC-PRESSURE Pressure Switch PR RS SW-05-1 Test Armed 3 4 YW RS-1 RELEASE SOLENOID BLBR RD OR SW-05-2 Test Armed 3 4 J4-13 SW-05 ZB5AD2 TEST/ARM Switch RS2 PR SW-05-1 Test Armed 3 4 YW PS-1 Pressure Switch WH 14 PWS-01 24VDC 18W POWER 24VDC Power Suppl CA CB CC AU1AU1 AU2AU2 TR2 MAD-01 DEVICE MANUAL ACTIVATION GAS VALVES SHOULD BE WIRED TO MASTER CORE BOARD ONLY. RDRD GV-1 24V DC Gas Valve LGV PK TERMINAL LGV USED FOR 24VDC POWERED GAS VALVES ONLY. DWG NO JOB NO DATE DRAWN BY JOB NAME DESCRIPTION OF OPERATION TYPE DRAWING TITLE 6037327 Taier Restaurant... FACTORY SC-E200111MA 6/6/2023 ECP #1-7 Fire System #1 TANK FS - 4.0/4.0/4.0/4.0. FS-1: MASTER DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 6037327 Taier Restaurant - Arcadia SC-E100111MA 6/6/2023 INSTALL ECP #2-1 Mixed Voltage w/ control for 1 3Ph Exhaust Fan, 1 120V 1Ph Supply Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. BREAKER PANEL TO PRIMARY CONTROL PANEL Responsibility: Electrician BREAKER PANEL PRIMARY CONTROL PANEL BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED BREAKER 1PH CONTROL POWER. DO NOT WIRE TO GFCI OR SHUNT TRIP BREAKER. Hot Neutral H1 N1 120 V 15 A Ground GND 1ST HOOD LIGHT BREAKER SHARED W/ CONTROL POWER. SWITCH #1 BREAKER 1PH MCA: MOCP: Hot Neutral L1 FN1 GND Ground SUP-7 115 V 7.2 A 15 A BREAKER PANEL TO FANS Responsibility: Electrician BREAKER PANEL FANS BREAKER 1PH MCA: MOCP: POWER TO ECM FANS HOT NEUTRAL 115V 11.1A EXH-3 Ground 20A CONTROL PANEL TO FANS Responsibility: Electrician PRIMARY PANEL FANS SHIELDED TWISTED PAIR PWM SPEED SIGNAL CONTROL PANEL TO ECM OUTDOOR RATED FEED STP THROUGH INNER COOLING TUBE. ALLOW FOR ENOUGH SLACK ON STP FOR PROPER HINGING. (EXHAUST ONLY) NOTE: PWM SIGNAL IS POLARITY SENSITIVE. NIDEC MOTOR TELCO MOTOR BK TO GR BK TO YW RD TO RD ZIEHL MOTOR BK TO BK P1A P1B EXH-3 ECM-01 FAN: 03 RED(+) BLACK(-) ECM-01 RED(+) BLACK(-) Load Wiring WIRE DIRECT TO STARTER BLACK WHITE GREEN WIRE TO FACTORY PROVIDED CONDUIT DROP FLA: HP: VOLT: T1 T2 LEG 1 / HOT LEG 2 / NEUTRAL GND GROUND C-1 SUP-7 07FAN: 5.8 0.333 115 V CONTROL PANEL TO ACCESSORY ITEMS Responsibility: Electrician CONTROL PANEL COMPONENT ALL SWITCHES FACTORY WIRED CAT-5 CONNECTION CONTROL PANEL SWITCHES TO J4 CONTROL PANEL HOOD LIGHTS TO 1400 W MAX WIRE TO J-BOX ON TOP OF HOOD B1 W1 GND BLACK WHITE GREEN HOOD LIGHTS 1 WIRE TO CONTROL BOARD. INSTALL SENSOR IN ROOM AWAY FROM HEAT SOURCES. DO NOT INSTALL SENSOR CONTROL PANEL KITCHEN TEMP TO SENSOR ON THE CEILING GRID, SEE MANUAL. T1A T1B ROOM TEMP FACTORY WIRED TEMPERATURE SENSOR. MOUNTED IN EXHAUST DUCT CONTROL PANEL DUCT SENSOR TO T2A T2B HOOD 3 RISER 1 CONTROL PANEL GAS VALVE TO 120V ONLY ONLY ENERGIZED THROUGH LCD HMI WHEN FIRE SYSTEM ARMED. GAS N1 HOT TO GAS VALVE NEUTRAL GAS SOLENOID THE FOLLOWING CONNECTIONS MAY OR MAY NOT BE REQUIRED BASED ON JOBSITE SPECIFICATIONS CONTROL PANEL EXTERNAL SIGNAL FOR SHUNT TRIP ST TERMINAL IS ENERGIZED IN FIRE CONDITION. CONTROL PANEL EXTERNAL SIGNAL FOR CONTACTOR COIL KS TERMINAL IS DE-ENERGIZED IN FIRE CONDITION. ST N1 NEUTRAL FROM SHUNT COIL HOT TO SHUNT COIL SHUNT COIL KS N1 NEUTRAL_TO_CONTACTOR_COIL HOT_TO_CONTACTOR_COIL CONTACTOR_COIL SPARE CONTACTS WILL MAKE CONTROL PANEL ON/OFF WITH DRY CONTACT SUPPLY FAN COMMON TO NORMALLY OPEN WHEN SUPPLY FAN IS ON. GROUP 1 SFC1 SFO1 COMMON NORMALLY OPEN SFC2 SFO2 COMMON NORMALLY OPEN CONTROL PANEL EXTERNAL TO SWITCH SIGNAL SWITCH THROUGH BMS WILL ACTIVATE ZONE1 FANS AND LIGHTS H1 IO1 BMS SWITCH C NO CONTROL PANEL GAS VALVE TO 24V DC ONLY ONLY ENERGIZED THROUGH LCD HMI WHEN FIRE SYSTEM ARMED. (NOT NEEDED IF USING 120V GAS VALVE). LGV N1D POSITIVE TO GAS VALVE NEGATIVE GAS SOLENOID CONTROL PANEL TO FIRE SYSTEM Responsibility: ALARM CONTRACTOR CONTROL PANEL COMPONENT CONTROL PANEL BUILDING SIGNAL FOR FIRE ALARM PANEL AL1 AL2 J9 BUILDING ALARM PANEL FIRE INPUT WIRE DIRECTLY TO CORE CIRCUIT BOARD. AL1 WILL MAKE AL2 IN FIRE CONDITION. CONTROL PANEL BUILDING SIGNAL FOR TROUBLE TROUBLE RELAY CONTACTS WILL MAKE TBC TO TBL IN TROUBLE CONDITION. BUILDING ALARM PANEL ALARM TBC TBL COMMON NORMALLY CLOSED CONTROL PANEL TO FIRE SYSTEM Responsibility: CERTIFIED INSTALLER CONTROL PANEL COMPONENT FIRE STAT SUPERVISED LOOP May be mixed factory and field wiring. See Installation Schematic. Multiple fire sensors possible. HIGH TEMP WIRE (842 F), PN: SLPCON-xFT required for all Supervised Loop wiring in contact with a hood. All other wiring shall be PN: 6320UL, Belden or similar. 21 22 23 24 FS-01 BK WH Fire Stat FS-02 BK WH Fire Stat CONTROL PANEL MOUNTED FIRE TO DUCT DETECTION STAT(S) FIRE STATS CONTROL PANEL SYSTEM PULL TO FIRE STATION MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM LOOP. Multiple manual actuation possible. Multiple manual actuation possible. A Plug jumper with wires from pin1 to pin4 and from pin2 to pin3 is mounted on J10, remove the jumpers and wire in the supervised actuation loop. Microswitch MS-01 is optional for fire system interlock. Auxiliary Interlock (AUX-01): Wire AU1 / AU2 of adjacent Master FS panel(s) in each manual activation loop for simultaneous activation. See Fire system drawings for more information. 101 102 103 104 AUX-01 AU1 AU2 PULL STATION MS-01 C NO Micro SW MAD-01 C NO Manual Actuation Device Adjacent FS Panel SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . e c o n a i r . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NFP A WIT H IN S LI D TE R C U S MASTER DRAWING 3/4" = 1'-0" 6037327 10 JG 6/6/2023 Ea s t e r n L A & O r a n g e C t y M e c h 30 0 2 D o w A v e n u e , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 5 0 3 - 0 7 7 7 E M A I L : r e g 1 4 4 @ e c o n a i r . c o m Ta i e r R e s t a u r a n t - A r c a d i a Ar c a d i a , C A , 9 1 0 0 7 40 0 S o u t h B a l d w i n A v e n u e , S u i t e 2 3 1 DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 6037327 Taier Restaurant - Arcadia SC-E100111MA 6/6/2023 INSTALL ECP #2-2 Mixed Voltage w/ control for 1 3Ph Exhaust Fan, 1 120V 1Ph Supply Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. CAT-5 CONNECTIONCONTROL PANEL MASTER FS TO BOARD. PLACE END OF LINE PLUG EOL120A IN EMPTY JACK. PN: EOL120A CORE PCB ADDITIONAL DEVICES MAY BE INLINE. ECPM03 UNLESS VFD, PCU, OR OTHER COMPONENT IN SERIES. J3 J5 J6 CONTROL PANEL MASTER FS TO PANEL WIRE TO LIKE TERMINALS IN ALL CORE PANELS THAT MUST ACTIVATE TOGETHER. SET MASTER & SLAVE DIP SWITCHES PER FIRE SYSTEM SHIELDED TWISTED PAIR INTERLOCK NETWORK MASTER CORE MANUAL. CA CB CC BLACK RED SHIELD CA CB CC TANK PROTECTION ELECTRICAL DETAIL 02/10/2021 Rev. 2 ELECTRICIAN: 1. WIRE MAIN CONTROL PANEL PER INCLUDED SCHEMATIC 2. WIRE ALL FANS PER INCLUDED SCHEMATIC 3. WIRE SHUNT TRIP BREAKER (OPTIONAL) 4. WIRE UDS APPLIANCE KILL SWITCH, IF EQUIPPED (OPTIONAL) 5. WIRE GAS VALVE NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS EXHAUST HOOD 36 INCHES CLEARANCE REQUIRED IN FRONT OF ALL UTILITY CABINET DOORS THE PANEL SHALL ALSO BE LOCATED IN AN ACCESSIBLE AREA WHERE THE AUDIBLE AND VISUAL ALARMS CAN BE HEARD AND SEEN GASELECTRIC ELECTRICAL CONTRACTOR REQUIREMENT ITEM CONNECTION IN PANEL CONNECTION IN DEVICE VOLTAGE AMPERAGE COMMENTS SHUNT TRIP BREAKER (OPTIONAL)ST & N1 BREAKER COIL (A1 & A2) 120 VAC < 4 AMPS ST TO A1 ON SHUNT BREAKER COIL, AND NEUTRAL TO A2 ON SHUNT TRIP BREAKER COIL CONTROL PANEL POWER H1 & N1 + GROUND CIRCUIT BREAKER 120 VAC 15 AMPS CONTROL PANEL POWER MUST NOT BE RUN THROUGH SHUNT TRIP BREAKER UDS APPLIANCE KILL SWITCH (OPTIONAL)KTS & N1 KTS & N1 120 VAC < 4 AMPS KILL SWITCH TERMINALS MUST BE IN SERIES WITH OTHER KILL SWITCHES REMOTE 120VAC ANSUL AUTOMAN (OPTIONAL)AU1, AU2 SOLENOID 120 VAC < 6 AMPS 120V TO AU1, AU2 TO ANSUL ELECTRIC AUTOMAN, ANSUL SOLENOID TO NEUTRAL GAS VALVE LGV & N1D (IF 24 VDC) GAS & N1 (IF 120 VAC) RED/RED/GREEN 24 VDC OR 120 VAC < 1.0 AMPS IF 24 VDC - 2 WIRES & GROUND, N1D TO RED, LGV TO RED, AND GREEN TO GROUND IF 120 VAC - 2 WIRES & GROUND GAS TO RED, N1 TO RED, AND GREEN TO GROUND SHUNT TRIP BREAKER (OPTIONAL) -2 WIRES, 120VAC -ST TO A1 ON SHUNT BREAKER -NEUTRAL TO A2 ON SHUNT TRIP BREAKER POWER TO ELECTRIC APPLIANCE CONTROL PANEL POWER -2 WIRES & GROUND -120 VAC, 15 AMP SERVICE -WIRE TO H1 AND N1, GROUND -POWER MUST NOT ORIGINATE FROM SHUNT TRIP BREAKER GAS VALVE POWER -2 WIRES & GROUND -24 VDC WIRE TO LGV & N1D -120 VAC WIRE TO GAS &N1 GAS VALVE -STRAINER MUST BE INSTALLED UPSTREAM OF VALVE COOKING APPLIANCE(S) DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 6037327 Taier Restaurant - Arcadia SC-E100111MA 6/6/2023 INSTALL ECP #2-3 Fire System #2 TANK FS - 4.0. FS-2: MASTER TANK PROTECTION LOW-VOLTAGE DETAIL 02/10/2021 Rev. 2 ALARM CONTRACTOR: 1. WIRE MANUAL ACTUATION DEVICE(S), REMOTE FIRESTAT(S), CORE INTERLOCK(S), FIRE SENSOR(S) AND FIRE ALARM CONTACTS 2. COMPLETE FINAL HOOKUP OF SYSTEM 3. VERIFY FINAL FIRE SYSTEM TEST ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES 36 INCHES CLEARANCE REQUIRED IN FRONT OF ALL UTILITY CABINET DOORS THE PANEL SHALL ALSO BE LOCATED IN AN ACCESSIBLE AREA WHERE THE AUDIBLE AND VISUAL ALARMS CAN BE HEARD AND SEEN EXHAUST HOOD ELECTRIC GAS NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS ALARM CONTRACTOR REQUIREMENT ITEM CONNECTION IN PANEL CONNECTION ON DEVICE VOLTAGE AMPERAGE COMMENTS MANUAL ACTUATION DEVICE(S) 101 AND 104 102 AND 103 1 & 2 24 VDC < 1.0 AMPS WIRE MANUAL ACTUATION DEVICE TERMINAL 1 BETWEEN CORE PANEL TERMINALS 102 AND 103 WIRE MANUAL ACTUATION DEVICE TERMINAL 2 BETWEEN CORE PANEL TERMINALS 101 AND 104 JUMPER 101 TO 104 AND 102 TO 103 IF NO MANUAL ACTUATION DEVICE IS INSTALLED MANUAL ACTUATION DEVICE COVER N/A N/A N/A N/A MANUAL ACTUATION DEVICE COVER MUST BE INSTALLED IF SURFACE MOUNTED, USE COVER EXTENSION STI-6531B REMOTE FIRESTAT SENSOR(S) 21 AND 24 22 AND 23 BLACK AND WHITE 24 VDC < 1.0 AMPS WIRE FIRE SENSOR WHITE WIRES BETWEEN HOOD CORE PANEL TERMINALS 22 AND 23 WIRE FIRE SENSOR BLACK WIRE BETWEEN HOOD CORE PANEL TERMINALS 21 AND 24 HIGH TEMP (842°F) #CW04427 (WHT) & #CW04427B (BLK)WIRE OR SIMILAR ONLY IF RAN OVER TOP OF HOOD; OTHERWISE BELDEN #6320UL OR SIMILAR PLENUM RATED WIRE; SEE FIGURE 1 FIRE ALARM CONTACT AL1, AL2 VARIES 50V MAX (AC/DC) UP TO 1 AMP FIRE ALARM RELAY CONTACTS FOR BUILDING FIRE ALARM LOCATED IN THE CORE ELECTRICAL CONTROL PANEL CORE INTERLOCK(S)ILA, ILB, ILC ILA, ILB, ILC RS-485 COMMUNICATIONS SIGNAL CORE SYSTEM (1) ILA, TO CORE SYSTEM (2) ILA. CORE SYSTEM (1) ILB, TO CORE SYSTEM (2) ILB. CORE SYSTEM (1) ILC, TO CORE SYSTEM (2) ILC. USE BELDEN# 88760 OR SIMILAR WIRE TROUBLE CONTACT TBC, TBL, TOK VARIES MAX 120 VAC UP TO 6 AMPS WIRE TO TBL & TBC NORMALLY OPEN CONTACT, CLOSES IN TROUBLE CONDITION CORE COMMUNICATIONS CABLE RJ-45 Jack INTERNET CONNECTION SIGNAL <1.0 AMPS TYPICAL CONNECTION CAT5 CABLE TO LOCAL AREA NETWORK VIA ETHERNET SWITCH OR WIRELESS ROUTER WITH VALID INTERNET CONNECTION 42 TO 48 INCHES ABOVE FLOOR LEVEL TO CENTER OF PUSH STATION MANUAL ACTUATION DEVICE 10 TO 20 FEET FROM HOOD LOCATED NEAR POINT OF EGRESS FROM HOOD MANUAL ACTUATION DEVICE WIRES -4 WIRES, 24VDC WIRE (TERMINAL 1) BETWEEN 102 AND 103 -WIRE (TERMINAL 2) BETWEEN 101 AND 104 -ADDITIONAL PULL STATIONS WIRED IN SUPERVISED LOOP -USE BELDEN #6320UL OR SIMILAR WIRE -SEE FIGURE 2 MANUAL ACTUATION DEVICE PART #STI-SS2431 PROTECTIVE COVER MUST BE INSTALLED SUPERVISED LOOP -4 WIRES, 24VDC CONNECT BLACK WIRES BETWEEN 21 AND 24 IN PANEL, CONNECT WHITE (OR RED) WIRES BETWEEN 22 AND 23 IN PANEL -ADDITIONAL FIRESTATS, WIRED IN SUPERVISED LOOP -USE HIGH TEMP (842°F) #CW04427 (WHT) & #CW04227B (BLK)WIRE ONLY IF RAN OVER TOP OF HOOD; OTHERWISE BELDEN #6320UL OR SIMILAR PLENUM RATED WIRE -SEE FIGURE 1 CORE COMMUNICATIONS CABLE -CAT5 CABLE MUST BE INSTALLED TO A LOCAL AREA NETWORK WITH VALID INTERNET ACCESS VIA ETHERNET SWITCH OR WIRELESS ROUTER CORE INTERLOCK -2 WIRES + SHIELD -USE BELDEN#88760 OR SIMILAR WIRE -SEE FIGURE 3 FIRE ALARM PANEL FIRE ALARM CONTACT -2 WIRES WIRED TO NORMALLY OPEN CONTACTS (CLOSES IN FIRE CONDITION) -CORE CONTROL PANEL AL1 AND AL2 -SEE FIGURE 2 TROUBLE CONTACT -2 WIRES TO NORMALLY OPEN CONTACTS (CLOSE IN TROUBLE CONDITION) -CORE PANEL TERMINALS TBL AND TBC -SEE FIGURE 4 COOKING APPLIANCE(S) DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 6037327 Taier Restaurant - Arcadia SC-E100111MA 6/6/2023 INSTALL ECP #2-4 Fire System #2 TANK FS - 4.0. FS-2: MASTER TANK PROTECTION LOW-VOLTAGE FIGURES 02/10/2021 Rev. 17 AL1 AL2 END OF LINE DEVICE WIRING CONNECTIONS FOR FIRE ALARM CONTACT FIGURE 2 CORE CONTROL PANEL FIRE ALARM CONTACT ALARM INPUT BUILDING FIRE ALARM SHIELDED TWISTED PAIR ILA ILC ILB ILA BK ILB RD BK RD WIRING CONNECTIONS FOR CORE INTERLOCK FIGURE 3 ILC ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES SUPERVISION SWITCH 1 2 C BUILDING FIRE ALARM TROUBLE INPUT CORE CONTROL PANEL TROUBLE CONTACT NO C NC 1 C 2 SUPERVISION SWITCH SUPERVISION SWITCH END OF LINE DEVICE TBC TBLTOK WIRING CONNECTIONS FOR TROUBLE CONTACT FIGURE 4 BK-C BK-C 21 22 23 24 J2-1 J2-2 J2-4 J2-3 21 BK-C 101 102 103 104 J10-1 J10-2 J10-4 J10-3 21 BK-C WIRING CONNECTIONS FOR FIRESTAT LOOP FIGURE 1 WIRING CONNECTIONS FOR MANUAL ACTUATION LOOP FIGURE 1A BREAK WIRE BEFORE INSERTING INTO TERMINALS FIRE STAT-2 FIRE STAT-1 NO-WH (OR RD) NO-WH (OR RD) BREAK WIRE BEFORE INSERTING INTO TERMINALS NO-WH (OR RD) MANUAL ACTUATION DEVICE NO-WH (OR RD) MANUAL ACTUATION DEVICE MICROSWITCH/ NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS USE BELDEN #6320UL OR SIMILAR WIRE DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 6037327 Taier Restaurant - Arcadia SC-E100111MA 6/6/2023 INSTALL ECP #2-5 Fire System #2 TANK FS - 4.0. FS-2: MASTER SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . e c o n a i r . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NFP A WIT H IN S LI D TE R C U S MASTER DRAWING 3/4" = 1'-0" 6037327 11 JG 6/6/2023 Ea s t e r n L A & O r a n g e C t y M e c h 30 0 2 D o w A v e n u e , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 5 0 3 - 0 7 7 7 E M A I L : r e g 1 4 4 @ e c o n a i r . c o m Ta i e r R e s t a u r a n t - A r c a d i a Ar c a d i a , C A , 9 1 0 0 7 40 0 S o u t h B a l d w i n A v e n u e , S u i t e 2 3 1 WH BK A B C D E F G H I 1 2 3 4 5 6 7 8 9 10 FACTORY WIRING SCHEMATIC CIRCUIT BOARDS PANEL LID COMPONENT LIST LABEL DESCRIPTION ST-X varies Starter OL-X varies Overload C-X varies Contactor TS-x A/CP-PO-T4"-EXPL Duct Thermostat 120 VAC RELAY NO COM COIL NC 34 6 5 8 2 7 1 RA-x 24 VDC RELAY RD-x NO COM COIL NC 34 6 5 8 2 7 1 PS-1 MDP18-24A-1C Power Sup. 24VDC BK RA-x 34.110.0184.0 120V Relay DPDT WH RA-x 34.110.0184.0 120V Relay DPDT GR UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG. N1 H1 DC - GN D DC + 8H1 7PCU 6ST 5KS 4KTS 3GAS 2AR1 1N1 120VJ9 5OV1 4SF1 3EF1 2B1 1IO1 120VJ7 AR1 H1 2x N1 2x B1 EF1 SF1 BK IO1 N1 BK BK BK JUMPER W1 BK 14AWG BK 64 RD-1 BL PR DC+RO1 RD-x 34.110.0188.0 24VDC Light Relay BK WH SF1 7 8RA-2 A1 A2C-1 8 7RD-1 24V 1 2 3 4 5 6 7 8 9 10 11121314 J6 N1 ON/OFF WITH SUP N1 RO 1 NH FAN PANEL COOLING DRY CONTACTS (SHOWN DE-ENERGIZED) HOOD LIGHTS AR1 H1 JUMPER FIRE SYSTEM BK BK BK GAS KS ST NOTE: Configure ECPM03 for CORE ECPM03 J10 IL 1 A IL 1 B JUMPER MAKE UP AIR INTERLOCK. J3 ECPM03 or Previous EOL J5 MASTER CORE C RA-2-1 NO SFC1 SFO1 14 AWG YW C RA-2-2 NO SFC2 SFO2 14 AWG YW 24 X 18 X 8.62 BOX CONTROL INPUT 120V H1=LINE, N1=NEUTRAL, 15A BREAKER. DO NOT CONNECT TO SHUNT TRIP BREAKER. SEE INSTALLATION SCHEMATIC FOR ADDITIONAL REQ. LEGEND FIELD WIRING FACTORY WIRING BK- BLACK BL- BLUE BR- BROWN OR- ORANGE WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/GN STRIPE WH/BL- WH/BL STRIPE YW- YELLOW GY- GREY PR- PURPLE RD- RED GR- GREEN WH / B L BL H1N1 DC - DC + LN -+ PS-01 AC 24V GN D DC KSKS BK KS BK BK GAS ST P1 A ( + ) P1 B ( - ) N/A 69.0% BK EF1 PR WH GR / Y W WH / B L BL NH FAN SECONDARY PANEL COOLING IF NECESSARY EF1 WHBK JUMPER ECPM03 J10 IL 2 A IL 2 B TERMINAL GAS USED FOR 120V POWERED GAS VALVES ONLY DWG NO JOB NO DATE DRAWN BY JOB NAME DESCRIPTION OF OPERATION TYPE DRAWING TITLE 6037327 Taier Restaurant... FACTORY SC-E100111MA 6/6/2023 ECP #2-6 Mixed Voltage w/ control for 1 3Ph Exhaust Fan, 1 120V 1Ph Supply Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. A B C D E F G H I 1 2 3 4 5 6 7 8 9 10 FACTORY WIRING SCHEMATIC CIRCUIT BOARDS DCV Rev. 2.10.00 HMI Rev. 2.10.00 MOTOR POWER CIRCUITS. SEE INSTALLATION COMPONENT LIST LABEL DESCRIPTION ST-X varies Starter 120 VAC RELAY NO COM COIL NC 34 6 5 8 2 7 1 RA-x 24 VDC RELAY RD-x NO COM COIL NC 34 6 5 8 2 7 1 24 X 18 X 8.62 BOX DIAGRAM FOR FIELD WIRING REQUIREMENTS. C-X varies Contactor SM-X varies VFD LEGEND FIELD WIRING FACTORY WIRING BK- BLACK BL- BLUE BR- BROWN OR- ORANGE WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/GN STRIPE WH/BL- WH/BL STRIPE YW- YELLOW GY- GREY PR- PURPLE RD- RED GR- GREEN LR-X varies Line/Load Reactor DWG NO JOB NO DATE DRAWN BY JOB NAME DESCRIPTION OF OPERATION TYPE DRAWING TITLE 6037327 Taier Restaurant... FACTORY SC-E100111MA 6/6/2023 ECP #2-7 Mixed Voltage w/ control for 1 3Ph Exhaust Fan, 1 120V 1Ph Supply Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. BK WH T1 T2 T3 L1 L2 L3 1413 CONT: FLA: MTR: HP: L1 FN1 C-114 AWG 1 PH 15 A 115 V SUP-7 100-K09D10 5.8 0.333 A B C D E F G H I 1 2 3 4 5 6 7 8 9 10 FACTORY WIRING SCHEMATIC CORE FIRE PROTECTION COMPONENT LIST LABEL DESCRIPTION 120 VAC RELAY NO COM COIL NC 34 6 5 8 2 7 1 RA-x 24 VDC RELAY RD-x NO COM COIL NC 34 6 5 8 2 7 1 24 VOLT BATTERY PACK 5 AMP FUSE RD SHIELDED TWISTED PAIR PCB-2 J3-2 J4-1 J3-11 J4-3 J4-2 J4-8 J4-9 J4-12 J3-14 J4-5 J3-13 J3-4 J4-6 J3-10 J2-1 J2-2 J2-3 J2-4 J7-2 J7-3 J7-1 J3-1 J3-3 RD RD BR RD ALL 18AWG RD BK ORRD PKRD BRRD RD OR/BL BK 18AWG BK BK J3-5 J1-1 J1-2 RD BK BK RD FIRE STAT SUPERVISED LOOP May be mixed factory and field wiring. See Installation Schematic. Multiple fire sensors possible. + + RD BK BK RD Shield BK RD RS-485 CORE INTERLOCK NETWORK. Connection to other CORE Panels or Communication Module. See Installation Schematic for Connection. N1D 3xH1D3x DISCONNECT J1 21 22 23 24 16AWG WH N1 H1 PN: 1606-XLP-60EQ Adjust power supply to 27.5 Volts with an accurate Digital Volt Meter or with an HMI plugged into the CORE board. NL +- PSM-2 60W GR BK GND PCB-2 PCBCORE-APP CORE PCB PSM-2 1606-XLP-50E CORE POWER SUPPLY WS-x varies Water Solenoid LT-06 PNL-1163-0UR 24V Red Ind. Light LL-01 AQ5510 Surf. Level Sensor AA-01 SCE120LA3FP1B Audible Alarm PB-01 D7-F2X11 Prime/Reset Switch SW-04 BZ-2RQ1-A2 Tamper Switch SP-1 50000-805 Surfactant Pump PB-01 Prime / Reset A2A1 RD-20 Trouble Relay A2A1 RD-17 Fire Relay DRY CONTACTS (SHOWN DE-ENGERGIZED) AA-01 Audible Alarm SW-04 Door Tamper Switch C NO FS-01 BK WH Fire Stat FS-02 BK WH Fire Stat HIGH TEMP WIRE (842 F), PN: SLPCON-xFT required for all Supervised Loop wiring in contact with a hood. All other wiring shall be PN: 6320UL, Belden or similar. Factory mounted hood sensors will be terminated at junction box on top of hood. GV-1 varies 24v DC Gas Valve INTERLOCK FOR AUTOMAN ACTIVATION. Used for activating 120V automan or adjacent Master CORE panels during active Fire Condition.11 RD-18-1 14 YW J3-16 J3-8 BR 38 LT-6 R FIRE INDICATOR DIP Switch ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES. RD/GNRD A2A1 RD-19 Equipment Relay COOKING EQUIPMENT DISABLE RELAY. For UDS Kill Switch, wire EKC and EKS terminals to like terminals in UDS panel. 12 11 RD-19-1 14 EKC EST EKS YW INTERLOCK FOR AUTOMAN ACTIVATION. Used for activating 120V automan or adjacent Master CORE panels during active Fire Condition.11 RD-18-1 14 YW RD OR/BL A2A1 RD-18 Auxiliary Interlock Relay FS-XX 12-F28021-000360 Duct Fire Sensor LT-05 PNL-1163-0UY 24V YLW Ind. Light PS-01 Station STI-SS2431 Remote Puill/Push FOR SHIPMENT J10-1 J10-2 J10-3 J10-4 RD BK BK RD 101 102 103 104 MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM LOOP. Multiple manual actuation possible. A Plug jumper with wires from pin1 to pin4 and from pin2 to pin3 should be mounted on J10 if there is no manual actuation device and no microswitch. Jumper if water valve supervision switch is used MAD-01 C NO Manual Actuation Device MS-01 C NO Micro SW 1 2 3 4 5 6 7 8 SW 1 OPEN PUT END OF LINE PLUG IN EMPTY RJ45 J3 ECPM03 UNLESS PCU AFM OR OTHER COMPONENT IN SERIES. CAT-5 WIRING (MASTER ONLY) FIELD WIRED IF REMOTE PREWIRE RD-XX PLC-RPT-24DC/21 24VDC Phoenix Relay AUX-01 AU1 AU2 Auxiliary Interlock (AUX-01): Wire AU1 / AU2 of adjacent Master CORE panel(s) in each manual activation loop for simultaneous activation. AU1/AU2 will have continuity for 10 seconds if adjacent panel goes into fire condition, activating this CORE Panel but allowing for a reset after 10 seconds. NOTE: AU1/AU2 terminals of CORE Panel should not be wired into its own manual activation loop. Adjacent CORE Panel Master CORE set DIP SW 8 to CLOSED position. Slave CORE with address 1 set DIP SW 8 to CLOSED position. All other CORES set DIP SW 8 OPEN. 18AWG LEGEND FIELD WIRING FACTORY WIRING BK- BLACK BL- BLUE BR- BROWN OR- ORANGE WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/GN STRIPE WH/BL- WH/BL STRIPE YW- YELLOW GY- GREY PR- PURPLE RD- RED GR- GREEN FIRE INDICATOR FAULT CONDITION FLASH CODES 2 Release Solenoid 3 Pressure Switch 4 Auxiliary Fault 5 Microcontroller Fault 6 N/A 7 Supervised Loop 8 Ground Fault 9 Surfactant Low 10 Battery Voltage Low 11 AC Power Failure 12 Door Tamper Switch 13 Test Mode 14 CORE Interlock Network 15 Fault on Hood in Interlock Network 16 Fault on PCU in Interlock Network FIRE ALARM SYSTEM DRY CONTACTS. Termials AL1 & AL2 make in FIRE. To Building Fire Alarm Panel J9 AL1 AL2 J3-7 FIRE SYSTEM DRY CONTACTS. Dry contacts will make C2 to AR2 when system is armed. 12 11 RD-17-1 C2 AR2 14 AWG YW TROUBLE RELAY. Contact terminals TBC & TBL make if there is trouble. Contact terminals TBC & TOK make if the system is ok. 12 11 RD-20-1 14 TBC TBL TOK YW RD PS OR J4-9 PS EWC-PRESSURE Pressure Switch PR RS SW-05-1 Test Armed 3 4 YW RS-1 RELEASE SOLENOID BLBR RD OR SW-05-2 Test Armed 3 4 J4-13 SW-05 ZB5AD2 TEST/ARM Switch RS2 PR SW-05-1 Test Armed 3 4 YW PS-1 Pressure Switch WH 14 PWS-01 24VDC 18W POWER 24VDC Power Suppl CA CB CC AU1AU1 AU2AU2 TR2 MAD-01 DEVICE MANUAL ACTIVATION GAS VALVES SHOULD BE WIRED TO MASTER CORE BOARD ONLY. RDRD GV-1 24V DC Gas Valve LGV PK TERMINAL LGV USED FOR 24VDC POWERED GAS VALVES ONLY. DWG NO JOB NO DATE DRAWN BY JOB NAME DESCRIPTION OF OPERATION TYPE DRAWING TITLE 6037327 Taier Restaurant... FACTORY SC-E100111MA 6/6/2023 ECP #2-8 Fire System #2 TANK FS - 4.0. FS-2: MASTER SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . e c o n a i r . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NFP A WIT H IN S LI D TE R C U S MASTER DRAWING 3/4" = 1'-0" 6037327 12 JG 6/6/2023 Ea s t e r n L A & O r a n g e C t y M e c h 30 0 2 D o w A v e n u e , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 5 0 3 - 0 7 7 7 E M A I L : r e g 1 4 4 @ e c o n a i r . c o m Ta i e r R e s t a u r a n t - A r c a d i a Ar c a d i a , C A , 9 1 0 0 7 40 0 S o u t h B a l d w i n A v e n u e , S u i t e 2 3 1