HomeMy WebLinkAbout400 S Baldwin Ave - 2023 - Taier Arch plans11B-705.1Detectable warnings top diameter of0.45-0.4711.4mm-11.9mm base diameter of0.9-0.9222.9mm-23.4mm 0.2" 5.1mm(a) (ENLARGED) ELEVATION 0.65 min16.5 2.3-2.458-61 2.3-2.4 58-61 (b) PLAN FIGURE 11B-705.1SIZE AND SPACING OF TRUNCATED DOMES AA 2.3-2.4 TOP DIAMETER 0.45"-0.47" BASE DIAMETER 0.9"-0.92" ENLARGED PLAN 1. ONLY APPROVED DSA/AC DETECTABLE WARNING PRODUCTS AND DIRECTIONAL SURFACESSHALL BE INSTALLED.2. CURB RAMPS SHALL BE SLIP RESISTANT. Detectable warnings shall consist of raised truncated domes with a diameter of nominal 0.9 in (23 mm), a height of nominal 0.2 in (5 mm) and a center-to-center spacing of nominal 2.35 in (60 mm) and shall contrast visually withadjoining surfaces, either light-on-dark, or dark-on-light. DETECTABLE WARNINGS NOTES: Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 2 5 AR C A D I A , C A 9 1 0 0 7 7/18/2023 HEALTH CORRECTION BUILDING CORRECTION EX I S T I N G S I T E P L A N BU I L D I N G I N F O R M A T I O N T-1 T-1 T-2 T-3 G-1 G-2 G-3 A-0 A-1 A-2 A-3 A-4 A-5 A-6 A-7 M-1 M-2 M-3 M-4 sheet 1-14 P-1 P-2 P-3 E-1.1 E-1.2 E-2.1 E-2.2 E-2.3 E-3.1 E-4.1 Cover page ( site plan, building inf.) ADA Standard and Details Egress Plan, Occupancy Load Calculation Green Code Green Code Green Code Existing Floor/Ceiling Demolition Plan Existing and New Roof Plan New Reflected Ceiling Plan, Lighting Schedule New Floor Plan, Door Schedule, Finish Schedule Equipment Floor Plan, Equipment List Store Front Elevations, Interior Elevations Enlarged Restrooms Details Details Mechanical Legends Mechanical Plan Mechanical Roof Plan Code Compliance & Hood Details Hoods Details and Information Plumbing Legend Waste & Floor Plan Water & Gas Floor Plan General Notes & Legend Single Line and Panel Schedule Power Plans Equipment Schedule Roof Plan Lighting Plan Title 24 Forms DRAWINGS INDEX PROPOSED JOB SITE SPECIAL INSPECTION REQUIREMENTS 1. Limits of Special Inspection. All special inspection performed in accordance with Los Angeles County Building Code Chapter 17 shall be in addition to the inspections required by the City Building Division. No approval by the special inspector is to be construed as approval to proceed with additional work. 2. Required City Approval. All special inspectors performing inspection work shall complete all necessary applications and be approved by the City Building Division prior to providing any inspection service. PEDESTRIAN PROTECTION REQUIREMENTS 1. Approval and Permit. Pedestrian protection shall be provided in accordance with the requirements of Building Code Chapter 33. Approval shall be obtained from the CityBuilding Division prior to installation of any pedestrian protection. Wherelocated within the public right of way, a permit shall be obtained from the CityEngineer before placing any construction within the public right of way.2. Disable Access. Scaffolding shall not be incorporated into the pedestrian protection unless it complies with all disabled access clear height and width requirements of California Disabilities Act Accessibility Guidelines. Contractor shall assume all responsibility for removal and replacement of noncomplying pedestrian protection. The issuance of a permit shall not prevent the building official from requiring the correction of errors on these plans or from preventing any violation ofthe Code adopted by the City, relevant laws, ordinances, rules and/or regulations. Administrative Requirements note: DETECTABLE WARNING SCALE: 1/8"=1'-0" DETECTABLE WARNING DOME SCALE: N.I.S. PROJECT SUMMARY PROPERTY OWNER: COMPANY: RIDERWOOD USA Inc. CONTACT: KARLA ALBA EMAIL: CONSTRUCTION@SHOPSATSANTAANITA.COM TENANT / APPLICANT: TAIER SAN GABRIEL INC. 400 S BALDWIN AVE, SUITE 231 ARCADIA, CA 91007 GUOXING LI TEL: (626)802-7519 DESIGNER: MM INTERIOR DESIGN, INC. MONTEREY PARK, CA 91754 TEL: (626)476-0518 EMAIL: TIANMUS@GMAIL.COM - 2022 CALIFORNIA PLUMBING CODE (CPC) - 2022 CALIFORNIA MECHANICAL CODE (CMC) - 2022 CALIFORNIA ELECTRICAL CODE (CEC) - 2022 EDITION OF THE CALIFORNIA BUILDING CODE (CBC) OCCUPANCY GROUP: A2 TYPE OF CONSTRUCTION: TYPE IIB-SPRINKLERED BUILDING INFORMATION : BUILDING NUMBER OF STORIES: ONE APPLICABLE CODES : PROPOSED FLOOR AREA: 2,300 SQ.FT. GENERAL INFORMATION: ENGINEER: BK CONSULTING ENGINEERS TEL: (909)569-2586 EMAIL: BKENGINEERS88@GMAIL.COM VICINITY MAP NORTH - 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE - 2022 CALIFORNIA ENERGY CODE (T-24 CEC) SCOPE OF WORK: EXISTING RESTAURANT TENANT IMPROVEMENT 1. NEW KITCHEN LAYOUT AND EQUIPMENT,NEW HOOD SYSTEM 2. NEW DINING AREA SEATING AND FURNITURE 3. NEW ADA RESTROOMS, NEW OUT DOOR PATIO FENCE STYLE NO CHANGES ON STORE SIZE, STORE FRONT LOCATION, PATIO EXISTING OUTDOOR PATIO AREA: 290 SQ.FT. - ARCADIA MUNICIPAL CODE COMPLIANCE SUMMARY 1 ACCESSIBILITY TO PUBLIC BUILDINGS DOORS & MANEUVERING SPACE 2SCALE N.T.S.1 8 6 3 UNAUTHORIZED VEHICLESPARKED IN DESIGNATED ACCESSIBLE SPACES NOTDISPLAYING DISTINGUISHINGPLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONSWITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'SEXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT____________OR BY TELEPHONING A SITE ENTRANCE SIGNAGE SHALL BE POSTED IN A CONSPICUOUS PLACE AT EACH ENTRANCE TO OFF-STREETPARKING FACILITIES, OR IMMEDIATELY ADJACENT TO AND VISIBLE FROM EACH STALL OR SPACE. THE SIGN SHALL NOT BELESS THAN 17 INCHES BY 22 INCHES (432 mm BY 559 mm) IN SIZEWITH LETTERING NOT LESS THAN 1 INCH (25 mm) IN HEIGHT PER CBC 11B-502.8.2 11 SINGLE RESTROOMS MIN. CLR. PRIVACYLOCK ONDOOR FLUSH ACTIVATORON WIDE SIDE 17"-18" 24 " 48 " M I N . C L R . 32"18" A ROOM THAT HAS NOT MORE THAN ONE OFEACH TYPE OF SANITARY FIXTURE, ISINTENDED FOR USE BY ONLY ONE PERSON ATA TIME, HAS NO PARTITION AROUND THETOILET, AND HAS A DOOR THAT CAN BELOCKED BY THE ROOM OCCUPANT. DOORS SHALL NOT SWING INTO THE CLEARFLOOR SPACE OF OR CLEARANCE REQUIRED FOR ANY FIXTURE. OTHER THAN THE DOOR TOTHE ACCESSIBLE WATER CLOSETCOMPARTMENT, A DOOR IN ANY POSITION,MAY ENCROACH IN THE TURNING SPACE BY 12INCHES MAX. (11B-603.2.3) 9 FIGURE 11B-703.7.2.1 1. ONLY APPROVED DSA/AC DETECTABLE WARNINGPRODUCTS AND DIRECTIONAL SURFACES SHALL BEINSTALLED. 2. CURB RAMPS SHALL BE SLIP RESISTANT. Detectable warnings shall consist of raised truncated domes witha diameter of nominal 0.9 in (23 mm), a height of nominal 0.2 in (5 mm) and a center-to-center spacing of nominal 2.35 in (60 mm) and shall contrast visually with adjoining surfaces, either light-on-dark, or dark-on-light. DETECTABLE WARNINGS NOTES: 80" 1'-6" 1'-6" ONLY 80" VAN ACCESSIBLE PARKING 3'-0" 1'-6" 3" 3-1/2" 1'-1/2" 3'-0" 1'-6" 1'-1" 4" 1'-2"1'-2" 6"6" 1-1/2" 1'-6" 1'-6"FINE $250MINIMUM FINE $250MINIMUM ADA PARKING SIGN ADA SYMBOL 7 MODELNUMBERTRADENAMEPRODUCTMATERIAL 18" 60"MIN. MIN. 60" MI N . DIA.CL E A R MI N . 54 " M I N . MIN. K-118-4ANTIQUEFAUCETSBRASS CENTERLINEOF FIXTURE CENTERLINEOF FIXTURE LAVATORY CLEARANCES 11" KNEE CLEARANCES 30" WIDE 6" MAX. TOECLEARANCES17" MIN. 9" M I N . 27 " M I N . 29 " M I N . 34 " M A X . 40 " M A X . NOTES: A. Minimum 30" x40" clear space is provided in front of sink that allows forward approach. SEC 11B-306 B. Required clear space adjoins or overlaps an accessible route and extends 19" max. under lavatory. C. Lavatories adjacent to sidewalk shall have 18" min. from wall to counter of lav. SEC 11B-606.6. D. Sink is a maximum of 6-1/2" deep. SEC. 11B-606.7 E. Knee clearance under sink is a minimum of 27"high and 30"wide, and provides an absolute depth of 19" underneath the sink. SEC 11B-606.2. F. Drain and hot water piping is insulated or configured to prevent contact with pipe surface. G. There are no sharp or abrasive elements under sink. H. Faucets are lever type, electronically activated or approved self closing valves (min. 10 second open flow). SEC. 11B-606.4 Faucets are operable with one hand and do not require tight grasping pinching or twisting of the wrist. SEC 11B-309 I. 5 LB. Maximum force required to activate controls.J. Mirror shall be mounted so bottom edge is no higher than 40" to floor. SEC.11B-603.3. NOTES:30" WIDE x 48" DEEP MINIMUM CLEAR ACCESS IN FRONT OF FIXTURE (ONE FIXTURE ONLYREQUIRED). SEC 11B-602.9 ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND SPACE ADJOINS OROVERLAPS AN ACCESSIBLE ROUTE OR ADJOINS ANOTHER WHEELCHAIR CLEAR FLOORSPACE.17" MAXIMUM RIM HEIGHT ABOVE FLOOR.44" MAXIMUM HEIGHT OF FLUSH VALVE ABOVE FLOOR.5 LB. MAXIMUM PRESSURE TO OPERATE FLUSH VALVE. SEC. 11B-605.414" MINIMUM PROJECTION FROM WALL.FLOOR SURFACES ARE SMOOTH, HARD AND NONABSORBENT EXPANDING UPWARD AMINIMUM OF 5" ONTO WALLS. A B C DEF G WALL - MOUNTED WATER CLOSETS URINALS 25" MAX. REACH RANGES 5 Disabled Access Requirements 4 13 COMMERCIAL ACCESSIBILITY TO PUBLIC BUILDINGS 11B-705.1Detectable warnings top diameter of0.45-0.4711.4mm-11.9mm base diameter of0.9-0.9222.9mm-23.4mm 0.2"5.1mm(a) (ENLARGED) ELEVATION 0.65 min16.5 2.3-2.4 58-61 2.3-2.4 58-61 (b) PLAN FIGURE 11B-705.1SIZE AND SPACING OF TRUNCATED DOMES 9 229 6 max 152 76 2 17-25 432-635 (a) ELEVATION (b) PLAN 9 min 229 8 min203 11 min 279 29 m i n 73 7 (a) elevation (b) plan 30 m i n 76 2 25 max 635 1312 min 343 17 max 432 (a) WALL HUNG TYPE (b) STALL TYPE 1312 min 343 18 ' ' m i n 48''min 36 ' ' m i n MOTE THAN 24'' PLAN 30 m i n 12 max12.7 FIGURE 11B-302.2CARPET PILE HEIGHT 1/4 max6.4 FIGURE 11B-303.2 VERTICAL CHANGE IN LEVEL 1/4 6.4 1/46.4 1 2 1212.7 FIGURE 11B-303.3BEVELED CHANGE IN LEVEL 24 min610 44 m i n 11 1 8 latch approach, push side (j) Figure 11B-404.2.4.1 Maneuvering clearances at manual swinging doors and gates 32 min 813 90° hinged door (a) Figure 11B-404.2.3Clear width of doorways 48 m i n 12 1 9 front approach(a) 42 m i n 10 6 7 side approach(b) Figure 11B-404.2.4.2Maneuvering clearances at doorways without doors CHANGE IN LEVEL DETAIL Abrupt changes in level exceeding 4 inches in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall beidentified by warning curbs at least 6 inches in height above the walk or sidewalk surface or by guards or handrails with a guide rail centered 2 inches minimum and 4inches maximum above the surface of the walk or sidewalk. These requirements donot apply between a walk or sidewalk and an adjacent street or driveway. §11B-303.5 AA 2.3-2.4 TOP DIAMETER0.45"-0.47" BASE DIAMETER 0.9"-0.92" ENLARGED PLAN 18 min 457 Add 6 inches(152 mm) atexterior side of exterior door. 15 2 4 (a) front approach, pull side 12 1 9 (b)front approach, pull side 12 1 9 12 min 305 (c)front approach, pull side,door provided eith both closer and latch 15 2 4 914 (d)hinge approach, pull side 12 1 9 22 min 559 hinge approach,push side,door provided with both closer and latch (g) 15 2 4 24 min 610 (h)latch approach, pull side reserved 12 "MA X . 11B-206 . Accessible Routes 11B-206.2.1: At least one accessible route shall be provided within the sitefrom accessible parking spaces and accessible passenger loading zones; public streets and sidewalks; and public transportation stops to the accessible buildingor facility entrance they serve. Where more than one route is provided, all routesmust be accessible. 11B-206.2.2: At least one accessible route shall connect accessiblebuildings, accessible facilities, accessible elements and accessible spaces that are on the same site. 11B-206.2.3: At least one accessible route shall connect each story andmezzanine in multi-story buildings and facilities. 11B-206.3: Accessible routes shall coincide with or be located in the samearea as general circulation paths. Where circulation paths are interior, requiredaccessible routes shall also be interior; An accessible route shall not pass through kitchens, storage rooms, restrooms, closets or other spaces used forsimilar purposes, except as permitted by Chapter 10. 11 B-206.4: Entrances: Entrances shall be provided in accordance with11b-206.4 entrances. Entrance doors, doorways, and gates shall comply with11b-404 doors, doorways, and Gates and shall be on an accessible route complying with 11B-402 Accessible Routes; on an accessible route. 11B-206.4.1: All entrances and exterior ground-floor exits to buildings shall comply with section 11 B - 404 Doors, Doorways and Gates. 11B-206.4.2: Where direct access is provided for pedestrians from aparking structure to a building or facility entrance, each parking structure to be a building or facility entrance, each direct access to the building or facility entranceshall comply with 11B-404 Doors, Doorways, and Gates. 11B-208. Parking spaces 11B-208.2: Minimum number. Parking spaces shall be provided in accordance with table 11 B-208.2. 11B-208.2.4: Van parking spaces. For every six or fraction of six parkingspaces, at least one shall be a Van parking space. 11B-208.3.1: Location. Accessible parking spaces shall be on the shortestaccessible route from parking to a compliant entrance. Where parking serves more than one accessible entrance, spaces shall be disbursed and located onthe shortest accessible route to the accessible entrances. 11B-302 Floor surfaces11B-302.2: Carpet shall be securely attached. Carpet shall have the level loop, textured loop, level cut pile, level cut/uncut pile texture. File height shall be onehalf inch maximum. Exposed edges shall be fastened to floor surfaces and shallhave trim on the entire length of the exposed edge. Carpet edge trim shall comply with Section 11 B-303.11 B-302.3: Openings in floor or ground surfaces shall not allow passage of a sphere more than one half inch diameter except as allowed in Sections 11B-407.4 .3. (Platform to waste away your). 11 B-303 Changes in level11 B-303.2: Vertical changes in level of 1/4 inch high maximum shall be permitted to be vertical and without edge treatment.11 B-303.3: Changes in level between 1/4 inch high minimum and 1/2 inch highmaximum shall be beveled with the slope not steeper than 1:2. 11 B-303.4: Changes in level greater than 1/2 inch high shall be ramped andshall comply with Section 11 B-405 or more 11 B-406. 11 B-303.5: Abrupt changes in level exceeding 4 inches in a vertical dimensionbetween walks, sidewalks or other pedestrian ways and adjacent surfaces shall be identified by warning curbs at least 6 inches in height above the walk orsidewalk surface. Exception:1) A warning curb is not required between a walk or sidewalk and the adjacent street or driveway.11 B-304 Turning space11 B-304.2: Turning spaces shall not be sloped greater than 1:48. 11 B-304.3 .1: Circular turning space shall be 60 inches diameter minimum. Thespace shall be permitted to include knee and toe clearance complying with Section 11 B- 306.11 B-304.3 .2: T-Shaped turning space shall fit within a minimum 60 inch squarewith minimum 36 inch wide arms and leg. Arms shall extend the minimum of 12 inches beyond the leg on each side, and the leg shall extend a minimum of 24inches below the arms. Ends of the arms and leg shall be permitted to include me and told clearance complying with Section 11B- 306.11 B-304.4: Doors shall be permitted to swing into turning spaces. 11 B-306.2 Toe clearance11 B-306.2 .1: Toe space shall extend a minimum of 9 inches above the finish floor.11 B-306.2 .2: Toe clearance shall extend 25 inches maximum under anelement. 11 B-306.2.3: Toe clearance required as a part of clear floors pace shall extend17 inches minimum under the element.11 B - 402 Accessible routes 11 B-402.2: Accessible routes shall consist of one or more of the followingcomponents: walking surfaces with a running slope not steeper than 1:20 (5%), doorways, ramps, curb ramps (excluding the flared sides), elevators andplatform lifts. 11 B - 403 Walking surfaces 11 B-403.3: The running slope of walking surfaces shall not be steeper than 1:20 (5%). The cross slope of walking surfaces shall not be steeper than 1:48(2.083%). 11 B-403.5.1 Except at turn or passing spaces, the clear width for walkingsurfaces shall be 36 inches minimum. 11 B-403.5.1 The clear width for walking surfaces in corridors serving anoccupant load of 10 or more shall be 44 inches minimum. (exception 2) 11 B-403.5.1 The clear width for sidewalks and walks shall be 48 inches minimum. (exception 3) 11 B-403.5.1 The clear width for walking surfaces in corridors serving an occupant load of 10 or more shall be 44 inches minimum if serving elements onboth sides. (Exception 4) 11 B-403.7: All walks with continuous gradient shall have resting areas 60" in length at intervals of 400 feet maximum resting areas shall be at least as wideas the lock the slope of the resting area in all directions shall be 1:48 maximum. 11 B - 404 Doors, doorways, and Gates 11 B-206.5 Doors, doorways, and gates providing user passage shall be provided in accordance with 11B-206.5 Doors, Doorways, and Gates. Exception: Doors, doorways, and Gates designed to be operated only by security personnel shall not be required to comply. A sign visible from theapproach site complying with section 11 B - 703.5 shall be posted stating '"Entryrestricted and controlled by security personnel". 11 B-404.2.1: Revolving doors, gates, and turnstiles shall not be part of anaccessible route. 11 B-404.2.2: At least one of the activities of doorways with two leaves shallcomply with Sections 11 B-404.2 .3 Clear width and 11 B-404.2 .4 ManeuveringClearances. 11 B-404.2.3: Door openings shall provide a clear width of 32 inchesminimum. Clear openings of doorways this doors shall be measured between the face of the door and the stop, with the door open 90¡ã. Openings more than24 inches deep shall provide a clear opening of 36 inches minimum. There shall be no projections into the required openings lower than 34 inches above thefinish floor. Projections into the clear opening with above 34 inches and lessthan 80 inches above the finish floor or ground shall not exceed 4 inches. Exceptions:1. In alterations, a projection of 5/8 inch maximum into the required clearwidth shall be permitted for the latch side stop. 2. Door closers in doorstops shall be permitted to be 78 inches minimumabove the finish floor or ground. 11 B-404.2.9: Door and gate opening force. The force for pushing or pullingopen a door or gate other than fire doors shall be 5 pounds maximum. The force required to open fire doors shall not exceed 15 pounds.a. Interior hinged doors and gates: 5 pounds maximum. b. Sliding or folding doors: 5 pounds maximum.c. Required fire doors: the minimum opening force allowable by the appropriate administrative authority, not to exceed 15 pounds.d. Exterior hinged doors: 5 pounds maximum. Exceptions:1. Exterior doors to machinery spaces.2. When it a single location, if one of every eight exterior door leaves is apowered door, other exterior doors at the same location serving the same interior space may have a maximum opening force of 8.5 pounds. The poweredleaf shall be located closest to the accessible route. 11 B-404.2 .10: Swinging door and gate surfaces within 10 inches of the finishfloor vertically shall have a smooth surface on push side extending the full widthof the door. Parts creating horizontal or vertical joints in those services shall be within 1/16 inch of the same plane and be free of sharp or abrasive edges. 11 B - 405 Ramps11 B-405.2: Slope. Ramps shall have a slope not steeper than 1:12. 11 B-405.3: Cross slope shall not be steeper than 1:48.11B-405.4: Floor or ground surfaces of ramp runs shall comply with 11B-302 Floor or Ground Surfaces. Changes in level other than the running slope andcross slope are not permitted on ramp runs.11 B-405.5: The clear width of a ramp shall be 48 inches minimum. Handrails may project into the required width 3 1/2 inches on each side at thehandrail height.Exception: The clear width of ramps in residential uses serving an occupant loadof 50 or less shall be 36 inches minimum between handrails.11 B-405.6: The rise for any ramp run shall be 30 inches maximum. 11 B-405.7: Ramps shall have landings at the top and the bottom of each ramprun. 11 B-405.7.2: The landing clear width shall be at least as wide as the widestramp run leading to the landing.11 B-405.7.2.1: The Top landing shall be 60" wide by 60" long min. 11 B-40 5.7.3.1: Bottom landings shall extend 72" minimum in the direction ofthe ramp run11 B-405.7.4: Changes in direction. Landings between ramp runs that change direction shall have a clear landing width of 60" minimum, and shall extend 72"minimum in the direction of downward travel from the upper ramp run. 11 B-405.7 .5: Where doorways are located adjacent to a ramp, doorwaymaneuvering clearances may overlap the required landing area, however:1. Doors, when fully open, shall not reduce the required ramp and equipped by more than 3".2. Doors, and any position, shall not reduce the minimum dimension of theramp landing to less than 42". 11 B-405.9 .2: A curb 2" high minimum, or a barrier that prevents the passage ofa 4" diameter sphere shall be provided, uninterrupted, along the length of the ramp. 11 B-502 Parking spaces Car parking spaces: Shall be 216" long by 108" wide min.Van parking spaces: Shall be 216" wide by 144" wide. Exception: Van parking spaces may be 108" wide minimum where the accessfile is 96"wide minimum.11 B-502.3: Access aisles shall adjoin an accessible route. Two parking spaces shall be permitted to share a common access aisle.11 B-502.3 .1: Width: Access files shall be 60" wide minimum 11 B-502.3 .2: Length: Access aisles shall extend the full required length of theparking spaces they serve.11 B-502.3 .3: Markings: Access aisles shall be marked with a blue painted borderline around the perimeter. The area within the blue borderline shall bemarked with hatched lines a maximum of 36" on center in a color that contrastswith that of the aisle surface preferably blue or white. The words " NO PARKING" shall be painted on the surface in each access aisle white letters aminimum of 12" high and located be visible from the adjacent vehicular way. 11 B-502.3 .4: Location: Access aisle shall not overlap the vehicular way.Van parking space aisles shall be located on the passenger side of the parkingspace. 11 B - 504 Stairways 11 B - 504.2: Treads and risers. All steps on a flight of stairs shall have uniformriser heights and uniform tread depths. Risers shall be 4" high minimum, and 7"high maximum. Treads shall be 11" deep minimum. Open risers are not permitted. Exceptions:1. On exterior stairways an opening of not more than 1/2" may be permitted between the base of the riser and the tread.2. On exterior stairways, risers constructed of grating containing openings and not more than 1/2" may be permitted.11 B - 504.4: Tread surface shall not have a slope steeper than 1:48.11 B - 504.4 .1: Contrasting stripe. The upper approach to stairs and lower trade shall be marked by a stripe providing clear visual contrast. Exterior stairs shallhave all treads marked by a stripe providing clear visual contrast.11 B - 504.5: Nosings. The radius of curvature at the leading edge of the tread shall be one half inch maximum. Nosings that project be on the risers shall havethe underside of the leading edge curve or beveled. Risers are permitted the slope under the tread at an angle of 30¡ã maximum from vertical. The permittedprojection of the nosing shall extend 1 1/4" maximum over the tread below. 11 B-504.8: Floor identification. In an enclosed stairway, each level shall beidentified with a sign adjacent to the door entering the enclosed stairway. Signsshall be located adjacent to the latch side of the door. At the exit discharge level, the signs shall include a raised five pointed star located to the left of theidentifying lower-level. The outside diameter the start shall be the same as the height of the characters. 11 B-505 Handrails 11 B-505.2: Handrails shall be provided on both sides the stairs and ramps.Exceptions:1. In assembly areas, handrails are not required on both sides of aisle rampswhere a handrail is provided at either side or within the aisle.2. Curb ramps to require handrails. 3. At door landings, handrails are not required when the ramp is less than 6"in rise or 72" in length.11 B-505.3: Continuity. Handrails be continuous within the full length of each pair flight or ramp run. Inside handrails on switch back or dogleg stairs andramps shall be continuous between flights or runs. Exception: In assembly areas, handrails are not required adjacent to seating or within the aisle width.11 B-505.4: Height. Top of gripping surfaces of handrails shall be between 34"minimum and 38" maximum above walking surfaces, stair nosings, and ramp surfaces. Handrails shall be at a consistent height above walking surfaces, stairnosings, and ramp surfaces. 11 B-505.5: Clearance between handrail gripping surfaces and adjacent surfaceshall be 1 1/2" minimum. Handrails may be located in a recess if the recesses is 3" deep and 18" minimum above the top of the handrail.11 B-505.6: Handrail gripping surface shall be continuous along its length andshall not be obstructed along the top or sides. Where provided horizontal projections shall occur 1 1/2" minimum below the bottom of the handrail grippingsurface. 11 B-505.7 .1: Circular cross section. Handrail gripping surface with a circularcross-section shall have an outside dimension of 1 1/4" minimum and 2"maximum. 11 B-505.7 .2: Noncircular cross sections shall have a perimeter dimension ofbetween 4" minimum and 6 1/4" maximum and a cross-sectional dimension of 2 1/4" maximum11 B-505.10: Handrail extensions. Exceptions: 1. Extensions are not required for continuous to handrails at the inside turnof switch back or dogleg stairs and ramps.2. In alterations, where the extension of handrails would create a hazard, the extension may be turned 90¡ã from the ramp run.11 B-505.10 .1: Ramp handrails shall extend horizontally for 12" beyond the top and bottom of ramp runs. Extensions shall return to the wall, guard, or thelanding surface, or shall be continuous to the handrail of of an adjacent ramprun. 11 B-505.10 .2: Stair handrails shall extend horizontally for 12" beyond the topstep tread nosing. 11 B-505.10 .3: Stair handrails shall extend horizontally for (12" plus the depthof one stair tread) beyond the bottom step tread nosing. 11 B-603 Toilet and bathing rooms11 B-603.2 .1: Turning space complying with Section 11 B - 304 shallbe provided within the room. 11 B-603.2 .2: Overlap. Required clear floor spaces, clearances it fixtures, andturning space shall be permitted to overlap. 11 B-603.2 .3: Door swing shall not overlap the clear floor space or clearancerequired for any fixture. Other than the door to accessible water closetcompartment, a door in any position, may encroach into the turnings base by 12" maximum. (See Exceptions to 11 B-603.2 .3)11 B-603.3: Mirrors located above lavatories are countertops shall be installed with the bottom edge of the reflecting surface 40 inches maximum above thefinish floor. Mirrors not located above lavatories are countertops shall beinstalled with the bottom edge of the reflecting surface 35 inches maximum above the finish floor.11 B-603.4: Coat hooks, shelves and medicine cabinets. 11 B-603.5: Accessories. Where dispensers, waste receptacles, otheraccessories are provided in toilet facilities at least one of each type shall be located on an accessible route. All operable parts shall be 40 inches maximumabove the finish floor. 11 B-604 Water closets and toilet compartments.11 B-213.3.2: Where water closets are provided, at least5% but no fewer than one shall comply with Section 11B-604 11 B-604.2: The centerline of the water closets shall be between 17" min. and 18" max. From the sidewall or partition. 11 B-604.3 .1: Clearance around the water closets shall be 60 inches minimum measured perpendicular to the sidewalland 56" minimum measured perpendicular to the rear wall. A minimum 60" wide and 48" deep maneuvering space shall be provided in frontof the water closet. 11B-604.8.1. 9 min 229 8 min 203 11 min 279 27 m i n 68 6 (c) elevation @ lavatory KNEE CLEARANCETOE CLEARANCE SINK CLEARANCE (TOE AND KNEE) SPACE ALLOWANCE & REACHRANGES NOTES: 1. ONE FULL-UNOBSTRUCTED SIDE OF THECLEAR FLOOR OR GROUND SPACE FOR AWHEELCHAIR SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE OR ADJOINANOTHER WHEELCHAIR CLEAR FLOORSPACE. IF A CLEAR FLOOR OR GROUNDSPACE IS LOCATED IN AN ALCOVE OROTHERWISE CONFINED ON ALL OR PARTOF THREE SIDES, ADDITIONALMANEUVERING CLEARANCES SHALL BEPROVIDED.2. THE SPACE REQUIRED FOR AWHEELCHAIR TO MAKE AN 180-DEGREETURN IS A CLEAR SPACE OF 60 INCHESDIAMETER OR A T-SHAPED SPACE.SHOWN IN FIGURE b.3. IF THE CLEAR FLOOR SPACE ONLYALLOWS FORWARD APPROACH TO ANOBJECT, THE MAXIMUM HIGH FORWARDREACH ALLOWED SHALL BE 48 INCHES.THE MINIMUM LOW FORWARD REACH IS15 INCHES. IF THE HIGH FORWARD REACHIS OVER AN OBSTRUCTION, REACH ANDCLEARANCES SHALL BE AS SHOWN INFIGURE a.4. IF THE CLEAR FLOOR SPACE ALLOWSPARALLEL APPROACH BY A PERSON IN AWHEELCHAIR, THE MAXIMUM HIGH SIDEREACH ALLOWED SHALL BE 54 INCHES AND THE LOW SIDE REACH SHALL BE NOLESS THAN 9 INCHES ABOVE THE FLOORAS SHOWN IN (c), IF THE SIDE REACH ISOVER AND OBSTRUCTION. THE REACHAND CLEARANCES SHALL BE AS SHOWNIN (c). SPACE ALLOWANCE & REACH RANGES TOILET ROOM ACCESSORIES REACH RANGES ELECTRICAL CONTROLS AND SWITCHES REASH RANGES 11B-308.1.1: ELECTRICAL CONTROLS AND SWITCHES INTENDED TO BE USED BY THEOCCUPANT OF A ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLEOUTLETS APPLIANCES OF COOLING, HEATING AND VENTILATING EQUIPMENT SHALLBE LOCATED WITHIN ALLOWABLE REACH RANGES. LOW REACH SHALL BEMEASURED TO THE BOTTOM OF THE OUTLET BOX AND THE HIGH REACH SHALL BEMEASURED TO THE TOP OF THE OUTLET BOX. 11 B-308.1.2: ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES SHALL BELOCATED WITHIN ALLOWABLE REACH RANGES. LOW REACH SHALL BE MEASUREDTO THE BOTTOM OF THE OUTLET BOX AND HIGH REACH SHALL BE MEASURED TOTHE TOP OF THE OUTLET BOX. TRUNCATED DOMES DETAIL 14 PARKING SPACE SIGN 12 INTERNATIONAL SYMBOL OF ACCESSIBITY SIGN 15 ONLYPARKING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL COMPLY WITH FIGURE 11B-703.7.2.1. THE SYMBOL SHALL CONSIST OF AWHITE FIGURE ON A BLUE BACKGROUND. THE COLOR BLUESHALL APPROXIMATE FS 15090 IN FEDERAL STANDARD 595C. 24 min610 48 m i n 12 1 9 latch approach, push side, door provided with closer (k) 10 DOORWAYS WITHOUT DOORS OR GATES 54" MIN.@WALL MOUNTED WATER CLOSET 42" MIN.12"MAX. 33 " - 3 6 " 19 M I N . 24"MIN. 7"-9" 17 " - 1 9 " 17"-18" 12"MIN. 33 " - 3 6 " 36" MAX. 12"MAX.42" MIN. 59" MIN. @ FLOOR MOUNTED TOILET 33 " - 3 6 " 19 " M I N . 24"MIN.17 " - 1 9 " 7"-9" 36" MIN.6"MAX. 17"-18" 12"MIN. 33 " - 3 6 " 36" MIN.6"MAX. NOTES:HEIGHT OF WATER CLOSET SEAT SHALL BE 17" TO 19" ABOVE FLOOR. SEC11B604.4. FLUSH VALVE SHALL BE LOCATE ON WIDE SPACE SIDE OF TOILET (EXCEPTTANK TYPE). THE FORCE REQUIRED TO ACTIVATE THE FLUSH VALVE 44" MAX.TO FINISH FLOOR SHALL BE 5 LBS. MAXIMUM SEC 11B-604.6 1. 2. SIDE VIEW FLOOR - MOUNTED WATER CLOSETS FRONT VIEW (b)(a) SIDE VIEW WALL - MOUNTED WATER CLOSETS FRONT VIEW TOILETPAPERHOLDERWITHOUTSTOPS TOILETPAPERHOLDERWITHOUT STOPS T-2 AD A I N F O R M A T I O N N O T E A N D D E T A I L S Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 1 AR C A D I A , C A 9 1 0 0 7 6/5/2023 打单机打单机 打单机 打单 机 W/T 3' - 2 " 3' - 0 " 3'- 9 "4' 5' - 4 " 6' - 2 " 4' 4' - 1 " 24' mopLocker 7'-5"9'-3"12'-3" 3' 3' - 8 " 3'-3" LE D LE D L E D L E D LEDLED LEDLED LE D LE D LEDLED LEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLED R8A R8A R8A 13'-6 " 2 8 ' - 3 " 53'-5" 10 ' - 6 " 22'-10" 32 ' - 9 " 22' EG R E S S P L A N T-3 Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518 EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 2 5 AR C A D I A , C A 9 1 0 0 7 7/18/2023 HEALTH CORRECTION BUILDING CORRECTION EGRESS PLAN SCALE: 1/4"=1'-0" 1 EGRESS PLAN NOTES: 1 EXIT SIGNAGE, THE EXIT SIGNAGE MUST NOT LESS THAN 90 MINUTES CONTINUED ILLUMINATION IN CASE OF PRIMARY POWER LOSS. 2 SIGN OF OCCUPANT LOAD PROVIDE THE FOLLOWING SIGN WITH 1" HIGH LETTERING ON THE EXIT DOOR FRAME STATING: " THIS DOOR TO REMAIN UN-LUCKED WHEN BUILDING IS OCCUPIED." 3 2 3 POST SIGN: "MAXIMUM CAPACITY 46 PERSONS" Exit doors provided: 1 EGRESS PLAN NOTE: Exit doors required: 1 2" BLACK SAN SERIF UPPER CASE CHARACTERS RAISED 1/32" ON CLEAR PHOTOPOLYMERPLAQUE. MEDIUM HELVETCA OR APPV'D EQUAL. ALL TACTILE EXIT SIGNS ARE IN ADDITION TO ILLUMINATED EXIT SIGNS & INTERNATIONALSYMBOLS OF DISABILLITY. AT WALLS SECURE SIGN WITH VINYL FOAM TAPE. AT STOREFRONT LOCATIONS ATTACH SIGN TO GLASS WITH MACTAC CLEAR DOUBLE FACED TAPE AND BEHIND THESIGN MOUNT A FROSTED VINYL SHAPE OF SAME CONFIGURATION AS SIGN ON EXTERIOR FACE OF GLASS TO EXACTLY ALINE WITH SIGN. BRAILLEGRADE 2CONTRACTED 9" 5"EXIT SCALE N.I.S.EXIT SIGN/TACTILE EXIT SIGN EXIT 8'- 0 " 2'-0" EXIT 5' - 0 " ELECTRICALLY POWERED WITH UL 924,SELF-LUMINOUS AND PHOTOLUMINESCENCE EXIT SIGNS INSTALLED ABOVE EXITING FROND DOOR. ILLUMINATED AT ALL TIMES. NOTES: 1. EGRESS FROM A ROOM OR SPACE SHALL NOT PASS THROUGH ADJOINING OR INTERVENING ROOMS OR AREAS, EXCEPT WHERE SUCH ADJOINING ROOMS OR AREAS AND THAT AREA SERVED ARE ACCESSORY TO ONE OR THE OTHER AND PROVIDE A DISCERNIBLE PATH OF EGRESS TRAVEL TO AN EXIT. DOORS LOCATED IN PATH OF EGRESS SHALL NOT BE ABLE TO BE LOCKED TO PREVENT EGRESS. 2. EGRESS FROM A ROOM OR SPACE SHALL NOT PASS THROUGH KITCHEN, STORAGE ROOM, CLOSET OR SPACES USED FOR SIMILAR PURPOSES. 3. THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE THAN ONEOPERATION. 4. THE ASSEMBLY EXIT SHALL FRONT ON AS LEAST ONE STREET OR AN UNOCCUPIED SPACE OF NOT LESS THAN 20 FEET IN WIDTH THAT ADJOINS A STREET OR PUBLIC WAY. 5. EXITS SHALL DISCHARGE DIRECTLY TO THE EXTERIOR OF THE BUILDING. THE EXIT DISCHARGE SHALL BE AT GRADE OR SHALL PROVIDE A DIRECT PATH OF EGRESS TRAVEL TO GRADE. THE EXIT DISCHARGE SHALL NOT REENTER A BUILDING. H.C. ENTRANCE FRONT APPROACHDOOR CONSTRUCTION THRESHOLDS NOTE: THRESHOLDS AT DOORWAYS SHALL NOT EXCESS 3/4" IN HEIGHT FOR SLIDING DOORS SERVING DWELLING UNIT OR 1/2" FOR OTHER DOORS. RAISED THRESHOLDS ANDFLOOR LEVEL CHANGES GREATER THAN 1/4 INCH AT DOORWAYS SHALL BE BEVELEDWITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL. SCALE N.I.S.ACCESSIBILITY ENTRANCE SIGN AND VISUAL CHARACTER HEIGHT ELEVATIONS LOOKING AT ENTRANCE DOOR AT STOREFRONT 72"MAX. ADA ENTRANCE SIGN FIGURE 11B-703.7.2.1 ENTRANCES COMPLYING WITH SECTION 11B-404 SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITYCOMPLYING WITH SECTION 11B-703.7.2.1.DIRECTIONAL SIGNS COMPLYING WITH SECTION 11B-703.5 THATINDICATE THE LOCATION OF THE NEAREST ENTRANCECOMPLYING WITH SECTION 11B-404. DIRECTION SIGNS COMPLYING WITH SECTION 11B-703.5. INCLUDING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1.INDICATING THE ACCESSIBLE ROUTE TO THE NEAREST ACCESSIBLE ENTRANCE SHALL BE PROVIDED AT JUNCTIONS WHEN THE ACCESSIBLEROUTE DIVERGES FROM THE REGULAR CIRCULATION PATH. 40 " M I N . 70 " M A X . VISUAL CHARACTER HIGH 58" MAX. SCALE N.I.S.LOCATION OF TACTILE SIGNS AT DOORS 3 2 1 18 " M I N . CENTERED ONTACTILE CHARACTERS18" MIN. ℄FIGURE 703.4.2 LOCATION OF TACTILE SIGNS AT DOORS SCALE N.I.S.4 PATH OF TRAVEL ADA SEATING PER 5% OF TOTAL SEATS REQUIRED: 3 SEATS 60 " M A X . 48 " M A X . AREA OF REFUGE FIGURE 11B-703.4.1HEIGHT OF TACTILE CHARACTERSABOVE FINISH FLOOR OR GROUND AREA OF REFUGE FIGURE 11B-703.3.2POSITION OF BRAILLE 3/8-1/2 3/8 MIN. BRAILLE SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT IN A HORIZONTAL FORMAT, FLUSH LEFT OR CENTERED. IF TEXT IS MULTI-LINED, BRAILLE SHALL BE PLACEDBELOW THE ENTIRE TEXT. SIGN'S HEIGHT OF TACTILE CHARACTERS SCALE N.I.S.5 2 1 OCCUPANT LOAD USE DINING AREA KITCHEN AREA TOTAL OCCUPANT LOADFATOR 1/200 SQUARE FEET 580 920 2,300 NO. OFOCCPANTS 39 5 46 REQUIRED NUMBER OF EXITS FOR LESS THAN 50 OCCUPANTS IS ONE STORAGE & WALK WAY 1/300 800 2 1/15 400 S BALDWIN Ave. UNIT 2325, ARCADIA, CA 91007 Existing restaurant T.I. for new owner $300,000 TI-23-1292 Yes Yes N/A Yes Yes water is served $100,000 $70,000 0% MM INTERIOR DESIGN07 13 2023 MARILYN MO DESIGNER/PROJECT MANAGER 178 LADERA ST. MONTEREY PARK, CA 91754 (626)476-0518 Yes Yes N/A Locker DE M O L I T I O N C E I L I N G P L A N DE M O L I T I O N F L O O R P L A N A-0 Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 2 5 AR C A D I A , C A 9 1 0 0 7 7/18/2023 HEALTH CORRECTION BUILDING CORRECTION DEMOLITION FLOOR PLAN SCALE: 1/4"=1'-0" NOTES: FOR ALL REMODEL CONSTRUCTION, INCLUDING ELECTRICAL, PLUMBING, MECHANICAL CONSTRUCTION WORKS, CONTRACTOR MUST FIELD VERIFY BEFORE DOING DEMOLISH WORKS. IF THE DEMOLISH WALL IS LOAD BEARING WALL, JOB MUST STOP IMMEDIATELY. BUILDING DEPARTMENT NOTE: MINIMUM 50% OF ALL NONHAZARDOUS DEMOLITION MATERIALS SHALL BE RECYCLED. 1 DEMOLITION CEILING PLAN SCALE: 1/4"=1'-0" FLOOR DEMO PLAN NOTES: 1. REMOVED AND CLEAN ALL EXISTING EQUIPMENTS, FURNITURE, FLOOR SINKS, FLOOR DRAINS, WATER PIPES, WALLS, FLOOR AND WALL FINISHES, KEEP EXISTING DEMISING WALLS, COLUMNS AND EXTERIOR PATIO CEILING STRUCTURAL. 2. RELOCATE EXISTING FRONT DOORS. KEEP EXISTING ALUM. WINDOW FRAMING STYLE, ALUM. DOORS SIZE AND STYLE. 3. REPLACE EXISTING PATIO HANDRAIL, KEEP HANDRAIL HEIGHT AS 42" AS EXISTING. 1 2 31 2 2 1 1 1 1 11 1 1 1 1 1 11 1 1 1 1 1 1 1 DEMOLITION CEILING PLAN NOTES: 1. REMOVE EXISTING T-BAR CEILING, DRYWALL CEILING, AND ALL LIGHTING FIXTURES, REMOVE AND CLEAN EXISTING ELECTRICAL OUTLETS, WIRES AND JOIN BOX, SWITCHES. 2. EXISTING A/C SYSTEM TO REMAIN, KEEP EXISTING MAIN DUCT, REMOVE EXISTING RETURN AND SUPPLY DIFFUSER 3. KEEP EXISTING EXPOSED CEILING 21 1 1 1 1 1 1 1 1 1 1 1 1 1 2 731 LBS 181 LBS 181 LBS 68 LBS 94 LBS 68 LBS 68 LBS 1 1 2 3 3/4"CD 3/4"CD 3/4"OD MIN. 1% SLOPE BELOW ROOF (TYP.) 4 5 15'-0 " EX I S T I N G A N D N E W R O O F P L A N NE W R O O F T O P E Q U I P M E N T A-1 Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518 EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 2 5 AR C A D I A , C A 9 1 0 0 7 7/18/2023 HEALTH CORRECTION BUILDING CORRECTION NOTES: FOR ALL REMODEL CONSTRUCTION, INCLUDING ELECTRICAL, PLUMBING, MECHANICAL CONSTRUCTION WORKS, CONTRACTOR MUST FIELD VERIFY BEFORE DOING DEMOLISH WORKS. ROOF DEMOLITION PLAN SCALE: 1/8"=1'-0" NEW ROOF PLAN SCALE: 1/8"=1'-0" Landlord Note: Current A/C Equipment is not provided by Landlord1 1 1 EXISTING PARAPET LOCATION EXISTING PARAPET LOCATION EXISTING PARAPET LOCATION 2 2 LED LED LED LED LED LED LED LEDLED LEDLEDLED LED LED LED LED LED LED LED LED LED LED LEDLEDLEDLED LED LED LED LED LED LED LED LED LED LED LED LED LEDLED LED LED LED LED LED LED LED LED LED LED LED LEDLEDLEDLED LED LED LED LED LED LED LED LED LED LED LEDLEDLED LED LED LED LED LED LED LED LED LED LED LED LEDLEDLEDLEDLED LED LED LED LED LED LED LED LED LEDLED LEDLEDLEDLED LED LED LED LED LED LED LED LED LED LEDLEDLEDLEDLED LED LED LED LED LED LED LED LED LED LED LEDLEDLEDLED LED LED LED LED LED LED LED LED LED LEDLED LED LEDLED LED LED LED LED LED LED LED LED LED LED LED LEDLEDLEDLED LED LED LED LED LED LED LED LED LED LED LEDLEDLED LED LED LED LED LED LED LED LED LED LED LED LEDLEDLEDLEDLED LED LED LEDLEDLEDLED LEDLEDLEDLED LEDLEDLEDLED LEDLEDLEDLED LEDLEDLEDLEDLEDLEDLED LEDLEDLEDLED LEDLEDLEDLED LEDLEDLEDLED LEDLEDLEDLED LEDLEDLED LEDLEDLEDLED LEDLEDLEDLED LEDLED LED LED LED LEDLED LED LEDLEDLED LED LEDLED LED LED LEDLED LED LED LEDLED LED LED LEDLED LED LED LEDLED LED LEDLEDLED LED LEDLED LED LED LEDLED LED LED LEDLED LED LED LEDLED LED LEDLEDLED LED LEDLEDLED LED LEDLED LEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLED LEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLED LEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED D1 D1 D1 D1 D1 D1 D1 D1 D1 D1D1D1 NE W R E F L E C T E D C E I L I N G P L A N LI G H T I N G S C H E D U L E SO F I T D E T A I L S A-2 Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518 EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 2 5 AR C A D I A , C A 9 1 0 0 7 7/18/2023 HEALTH CORRECTION BUILDING CORRECTION NOTES: FOR ALL REMODEL CONSTRUCTION, INCLUDING ELECTRICAL, PLUMBING, MECHANICAL CONSTRUCTION WORKS, CONTRACTOR MUST FIELD VERIFY BEFORE DOING DEMOLISH WORKS. HEALTH DEPT CORRECTION NEW REFLECTED CEILING PLAN SCALE: 1/4"=1'-0" DESCRIPTIONITEM TYPE PROJECTOR LIGHTING LED LINEAR LIGHTING LOCATION RL2R-0330-BK/36V/LED/5W /3000K/36° RL35F-1230-WH/36V/LED/15W/36°/3000K RL5R-2330-WH/36V/LED/23W /40°/3000K LR10025/LED/25W/白光/LOGO灯 24"X24" RECESSED/4000K/48W R5 R6 R7 R8 R9 11030112/36V/LED/12W /60°/3000K PENDANT LIGHT W/E27 LAMPS RL35G-12-WH/36V/LED/5W/3000K/15°R1 HMAA-/36V/LED/15W /15°/3000KR2 15160205/36V/LED/5W /3000K/25°R4 R3 36V/LED/9W /24°/3000K/ R3A 36V/LED/9W /36°/3000K/ 36V/LED/9W /36°/3000KR3B DINING CEILING DINING CEILING DINING CEILING DINING CEILING WALL WASH RECESSED WITCH-HEAD LIGHT RECESSED WITCH-HEAD LIGHT CEILING MOUNTED WITCH-HEAD LIGHT RECESSED WITCH-HEAD LIGHT DINING CEILING WALL WASH RECESSED WITCH-HEAD LIGHT DINING CEILING WALL WASH CEILING MOUNTED WITCH-HEAD LIGHT DINING AREA CLOSETS RECESSED WITCH-HEAD LIGHT RECESSED DOWN LIGHTPASS THROUGH WINDOW CEILING SEALED RECESSED DOWN LIGHTKITCHEN,PREPARE AREA DINING CEILING CEILING MOUNTED WITCH-HEAD LIGHTDINING CEILING D1 KITCHEN/PREP./WASH/STORAGE T-BAR CEILING RECESSED LIGHTING DINING AREA DECO. 1 WHERE OCCURSS/S KICKPLATE B DOOR TYPE: HARDWARE : NOTES: GCB (E) EXISTING, (R) REMOVED, (S) SWITCH HARDWARE D REMARKSFRAMEDOORTYPE A MATERIALSIZE 3 NO. 2 1 QTY. DOOR SCHEDULE RATED 1) PROVIDE H.C. SIGN ON FRONT DOOR 2) PROVIDE SIGN STATING "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" @ 1" MIN. HT LETTER. 3) ALL EXTERIOR DOORS OPEN OUTWARD & SHALL BE TIGHT FITTING TO EFFECTIVELY PREVENT THE ENTRANCE OF FLIES & BODENTS. 4) PROVIDE SIGN LOCATED ABOVE & WITHIN 12" OF PANIC BAR READING: "FIRE EXIT ONLY". ALARM SOUNDS WHEN OPENED. 5) EXIT DOOR SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY ORANY SPECIAL KNOWLEDGE OR EFFORT. PROVIDE SELF-RELEASING LOCKING ON EXIT DOORS. 6) THE BOTTOM 10" OF ALL DOORS TO HAVE A SMOOTH UNINTERRUPTED SURFACES FOR 10" MIN. 7) DOOR HANDLES SHALL BE LEVER TYPE. PUSH/PULL OR EQUIPMENT. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8 LBS FOR EXTERIOR DOORS AND 5LBS FOR INTERIOR DOORS. 8) ALL MEANS OF EGRESS DOORS SHALL COMPLY WITH THE REQUIREMENTS OFSECTION 1008.1. a. MEANS OF EGRESS DOORS SHALL COMPLY WITH THE DISTINGUISHABLE FROM THE ADJACENT CONSTRUCTION AND FINISHES WITH NO MIRRORS, CURTAINS,DRAPES, DECORATIONS, OR SIMILAR MATERIALS. b. REQUIRED EXIT DOORS SHALL HAVE NOT LESS THAN 32-IN. CLEAR WIDTH, 80-IN. CLEAR HEIGHT, AND SHALL BE CAPABLE OF OPENING 90 DEGREES. THEMAXIMUM SWINGING DOOR LEAF WIDTH IS 48-IN. NOMINAL. c. EGRESS DOORS SHALL BE OF THE PIVOTED OR SIDE-HINGED SWINGING TYPE. d. THE FORCE FOR PUSHING OR PULLING OPEN INTERIOR SWINGING EGRESSDOORS, OTHER THAN FIRE DOORS, SHALL NOT EXCEED 5 POUNDS. FOR OTHER SWINGING DOORS, SHALL NOT EXCEED 5 POUNDS. FOR OTHER SWINGING DOORS, AS WELL AS SLIDING AND FOLDING DOORS, THE DOOR LATCH SHALLRELEASE WHEN SUBJECTED TO A 15-POUND FORCE. THE DOOR SHALL BE SET IN MOTION WHEN SUBJECTED TO A 30-POUND FORCE. THE DOOR SHALL SWING TO A FULL-OPEN POSITION WHEN SUBJECTED TO A 15-POUND FORCE.REVOLVING AND SLIDING DOORS MAY BE USED IN OTHER THAN GROUP H OCCUPANCIES AS EGRESS DOORS ONLY IF ALL OF THE REQUIREMENTS OF SECTION 1008.1.4.1 AND SECTION 1008.1.4.3, RESPECTIVELY, ARE MET.9) THE LEVER HARDWARE MUST BE SINGLE ACTION FROM INSIDE ON DOOR BELT. 10 " 7'- 0 " 7'- 0 " WOOD DOOR A SELF CLOSING B PRIVACY LOCKSET C S/S KICKPLATE 10"x34" D KEYED LOCKSET E DOOR HOLDER F LEVER HARDWARE G LATCH TYPE MEET ADA CODE EXISTING FRONT DOOR TO REMAINTEMPERED GLASS3'-0"x7'-0" (PAIR) 3'-0"x7'-0"x1-3/4"1 C A H PANIC HARDWARE E F SEE NOTES #1, #2, #3, #5 #7, #8 3'-0" A A SEE NOTES #7, #8 4'- 0 " 1'-0" 30 " - 4 4 " 3 STAINLESS STEEL DOUBLE SWING DOOR1'-6"x7'-0"x1-3/4"1 C A 7'- 0 " C 3'-0" 4 1'-6"x7'-0"x1-3/4"1 B EXISTING BACK DOOR TO REMAIN D E FA SEE NOTES #1, #2, #3, #5 #7, #8 干手机 纸巾盒 LEDLEDLED LED LED LED LED LED LED LED LED LEDLED LEDLED LEDLED LEDLED LED LED LED LED LED R8A R8A R8A 8'-3"5'7'-6" 6' - 4 " 12 ' - 4 " 2' - 3 " 3' 15 ' - 4 " 2'-4" 4'-2" 5' - 3 " 21'-8"8'-4" 2' 7' - 1 " 7'-4" 2'-6" 2' - 9 " 3' - 1 0 " 5' - 1 1 " 8'-1"4'-1" 4' - 3 " 7'-7" 2' - 9 " 1'-3" 10 ' - 6 " 5'22'-6" 8'-6"4' 9'-4"9'-3" 3' - 4 " 1'-7" 10 ' - 6 " 8' - 3 " 2' - 1 1 " 4'-3" 3' 2'-5"1' - 9 " 17 ' - 4 " 3' 9' - 3 " 5'-7" 2' 2' - 3 " 2'-2"4' - 5 " 3'-6" 3' - 1 1 " 2' - 2 " 3' 6'-5" 15 ' - 7 " 6' ± 5 ' - 5 " 14'-5 " 1 0 ' - 7 " 5' - 7 " 7'- 1 0 " 7'-2" DO O R S C H E D U L E A N D R O O M FI N I S H S C H E D U L E NE W F L O O R P L A N A-3 Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518 EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 2 5 AR C A D I A , C A 9 1 0 0 7 7/18/2023 HEALTH CORRECTION BUILDING CORRECTION KITCHEN AREA RESTROOMS ROOM NAME WALK WAY DINING AREA ITEM GY P . B O A R D W / P R I N T W/ 3 / 8 " R . C O V E D B A S E QU A R R Y T I L E , 6 " H T . LI G H T C O L O R C O V E D B A S E 4" H T C E R . T I L E W / 3 / 8 " R . QU A R I T Y T I L E CE R A M I C T I L E W/ L I G H T C O L O R P A I N T 2' X 2 ' W A T E R R E S I S T A N T " T " B A R V A L U E O F 7 0 % O R G R E A T E R SE M I . G L O S S A L I G H T R E F L E C T A N C E ST A I N L E S S S T E E L WA T E R R E S I S T A N T D R Y W A L L F. R . P . EG G S H E L L ROOM FINISH SCHEDULE FLOOR BASE WALL PAINT CEILING FINISH SCHEDULE NOTES: 1. FLOORING UNDER EQUIPMENT AND AT THE BASE COVES SHALL BE COMPLETELY SMOOTH.2. FINISHED IN ALL AREAS, OTHER THAN THE CUSTOMER WAITING OR DINING AREAS, MUST BE SMOOTH, NONABSORBENT, EASILY CLEANABLE, DURABLE AND LIGHTIN COLOR. (NOTE: LIGHT COLORED IS DEFINED AS HAVING A LIGHT REFLECTANCE VALUE OF 70% OR GREATER.)3. THE PAINT USED ON WALLS AND CEILINGS OF ALL KITCHEN, FOOD PREPARATION, WORK, AND STORAGE AREAS WILL BE A GLOSS OR SEMI-GLOSS ENAMEL. FINISHMATERIAL SHALL BE LIGHT IN COLOR WITH A REFLECTANCE VALUE OF 70% OR GREATER. CEILING SURFACES MUST BE SMOOTH, NONABSORBENT, DURABLE. PROVIDE SEMI-GLOSS PAINT OR BETTER CLEARLY INDICATE APPROVED CEILING SURFACES ON YOUR PLANS FOR THE AREA(S) LISTED AREA(S). 4. CEILING SURFACES MUST BE SMOOTH, NONABSORBENT, DURABLE. PROVIDE SEMI-GLOSS PAINT OR BETTER CLEARLY INDICATE APPROVED CEILING SURFACES ON YOUR PLANS FOR THE AREA(S) LISTED AREA(S). 5. A FLOOR THAT IS CONTINUOUS IN DESIGN EXTENDING AT LEAST FOUR(4) INCHES UP WALLS AND TOE KICKS IN A SEAMLESS MANNER, FORMING A MINIMUM 3/8"RADIUS COVE AS AN INTEGRAL UNIT IS REQUIRED IN THE EMPLOYEE CHANGE ROOM / RESTROOMS / STORAGE AREA(S).6. NEW BACK WALLS FOR COMMERCIAL KITCHEN COOK LINES, SHALL BE NON-COMBUSTIBLE CONSTRUCTION. ALL WALLS FINISH IN COOKING LINE AREA ARE AT LEAST7' HIGH STAINLESS STEEL, SEE FINISH SCHEDULE. ALL EQUIPMENT INSTALL SHALL BE PROVIDE AS REQUIRED CLEARANCES PER THE LISTING OF EACHEQUIPMENT'S MANUFACTURER'S INSTRUCTIONS. 7. PROVIDE MIN. 4" HIGH COVE BASE WITH MIN. 38" RADIUS. USE 6"X6" QUARRY TILE AND QUARRY TILE BASE IN TRAFFIC AREAS, PROVIDE SMOOTH FLOORING UNDER EQUIPMENT FLOOR. ALL WALL PAINT IS SEMI-GLOSS, EASILY WASHABLE PRINT IN RESTROOM, STORAGE ROOM, LOCKER AREA, PREPARE AREA, WASH AREA,SERVICE AREA.8. WALL FINISH IN WASHER AREA, PREPARE AREA ARE SMOOTH, NON-PATTERNED AND EASILY CLEANABLE STAINLESS STEEL FINISH.9. ADHESIVES AND SEALANTS USED ON THE PROJECT SHALL MEET THE REQUIREMENTS OF THE FOLLOWING STANDARDS: 1. ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS, SEALANT PRIMERS AND CAULKS SHALL COMPLY WITH LOCAL OR REGIONAL AIR POLLUTION CONTROL OR AIR QUALITY MANAGEMENT DISTRICT RULES WHERE APPLICABLE OR SCAQMD RULE 1168 VOC LIMITS, AS SHOWN IN TABLES 5.504.4.1 AND 5.504.4.2 2. AEROSOL ADHESIVES AND SMALLER UNIT SIZES OF ADHESIVES AND SEALANT OR CAULKING COMPOUNDS (IN UNITS OR PRODUCT, LESS PACKAGING, WHICH DO NOT WEIGH MORE THAN ONE POUND AND DO NOT CONSIST OF MORE THAN 16 FLUID OUNCES) SHALL COMPLY WITH STATEWIDE VOC STANDARDS AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS, OF CALIFORNIA CODE OF REGULATIONS, TITLE 17, COMMENCING WITHSECTION 94507. PO R C E I L A I N T I L E 2" H T S / S C O V E B A S E NEW FLOOR PLAN SCALE: 1/4"=1'-0" 1. EXISTING STORE FRONT REMAIN, RELOCATE GLASS FRONT DOORS 2. EXISTING OUTDOOR SEATING PATIO TO REMAIN, CHANGE FENCE 3. EXISTING BACK DOOR TO REMAIN 4. RENEW EXISTING KITCHEN FLOOR BY 6"X6" QUARRY TILE AND COVE BASE 5. ALL RECEPTION AND FEE PAY SERVICE BY STAFF FROM STORE FLOOR PLAN LEGEND STORE FRONT FIXED GLASS WALL,SEE #2 DETAIL @ A-7 FULL HEIGHT WALL, SEE DETAIL #3 @ A-7 NOTES: FOR ALL REMODEL CONSTRUCTION, INCLUDING ELECTRICAL, PLUMBING, MECHANICAL CONSTRUCTION WORKS, CONTRACTOR MUST FIELD VERIFY BEFORE DOING DEMOLISH WORKS. NEW FLOOR NOTES PREP./WASH/STORAGE AREA EX P O S E D C E I L I N G ST A I N L E S S S T E E L ST A I N L E S S S T E E L W/ 3 / 8 " R . C O V E D B A S E 1 EXISTING FULL HEIGHT WALL TO REMAIN CERAMIC AND QUARRY TILE MUST USE INTEGRAL(KEYED) COVED BASE. THE COVE BASE MUSTBE "KEYED-IN" TO THE FLOOR SURFACE. TO "KEY-IN", THE FLOOR IS SAW-CUT AT THE WALL/FLOOR JUNCTURE AND AN APPROVED BASE IS INSERTED AND GROUTED IN. SANITARYCOVED BASE TOPSET TILE (SLIM FOOT) IS NOT APPROVED. HEALTH DEPARTMENT NOTE FOR COVED BASE: 1 1 ALL FINISH MUST BE SMOOTH, EASY TO CLEAN, NONABSORBENT, AND DURABLE.2 THE PAINT BEING USED AT THE STORAGE AREA AND RESTROOMS FOR BOTH WALLS AND CEILINGS WILL BE SEMI-GLOSS ON THE FINISH SCHEDULE. 3 LOW WALL, SEE DETAIL #6 @ A-7 FUR WALL, SEE DETAIL #4 @ A-7 UNDER CEILING WALL, SEE DETAIL #1 @ A-7 1 1 2 2 2 2 3 1 2 2 2 3 4 4 F.S. T.D. F.S. F.S.F.S. F.S. F.S. F.S. F.S. F.D. F.D. F.D. HEALTH DEPARTMENT NOTE: 1. ALL DOORS OPENING TO THE OUTSIDE MUST BE RODENT PROOF (<14" GAP AT THE BOTTOM OF DOOR.) 1 B05 打单机打单机 打单机 打单 机 3' - 8 1 / 2 " W/T 3' - 2 " 3' - 0 " 干手机 纸巾盒 3'-8 1 / 2 " 4'-0" 5'- 4 " 6'- 0 " 3' - 9 " 4' - 1 " 24'-0" 8'-0" mopLocker U01F01B06 B01B02B03U02 C09C10H01 F02 C01 C02 C03 C04 C05 C05 H02 C06 U03 F01 F01 H03 C07 C08 REF.ICE B04U04 C11 F01 C12C13C09U02C14 F04 B06 F05 D06 U08 F03 F03 7'-4 1/2" F04 F04 F04 F04 P01P06P05F04 F04 D01 U05 C04 D01 U01 D01 P02 B02 B02 P02 P02 P03 P03 P04 9'-3"12'-2 1/2" C11 U02 F04 D07 P06 P07 LEDLEDLED LED LED LED LED LED LED LED LED LED LED LED LED LEDLEDLEDLED LED LED LED LED LED R8A R8A R8A 3'-8" PASS THROUGH WINDOW 5'-0" 3' - 6 1 / 2 " U02 D05 H04 D04 U02 D03 U04 D02 F.S.F.S. F.S. F.S. F.S. F.S. F.D. F.D.F.D. T.D. F.S. 17" MIN. 29 " M I N . 34 " M A X . D02 1 EQC PLUMB 3-COMP DISH SINK W/24" TWO DRAIN BOARD ON BOTH SIDE ALLSTRONGDT24243D-L 1/2"1/2"F.S. F05 2 GC GC EMPLOYEE LOCKERS6 COMPARTMENT GSWEL-6DR 6" ABOVE THE FINISH FLOOREXISTING EQUIPMENT TO REMAIN F04 lot GC GC COMMERCIAL DRY STORAGE SHELVING18" D W/5 TIERS METRO B01 1 PLUMP EQC ICE MAKER, CUBE-STYLE HoshizakiKM660MWJ 1/2"F.S.115 15 1 D03 1 EQC PLUMB PRE-RINSE FAUSET FISHERFISF-52922 1/4"1/4" B02 3 EQC EQC ONE DOOR REFRIGERATOR HoshizakiR1A-FS 115 4 1/3 B03 1 EQC EQC WATER FILTER EverpurePF-7FC-S 3/4"115 0.8 B04 1 EQC 36"WX30"D S/S WORK TABLE ALLSTRONGWT-3036-C B05 1 EQC EQC FOOD PREPARE TABLE HoshizakiPR67B 115 6.5 1/3 B06 2 EQC EQC WALL MOUNTED HANDSINKW/ HAND SOAP AND PAPER TOWEL DISP.GSWHS-1615S 1/2"1/2"2" C01 1 EQC EQC GAS SOUP POT RANGE PANTINSP-1 3/4"100 C02 1 EQC EQC GAS RICE COCKER TOWNRM-55 1/4"35 C03 1 EQC S/S RICE COCKER STAND24"X24" WITH UNDER SHELF ALLSTRONGES-P2424 C04 1 EQC 12"WX30"D S/S WORK TABLE ALLSTRONGWT-3012-C C05 2 EQC EQC GAS DEEP FIRE PANTINLT-GF122K 1/2"120 C06 1 EQC 84"WX30"D S/S WORK TABLE ALLSTRONGWT-3084-C C07 1 EQC 72"WX30"D S/S WORK TABLE ALLSTRONGWT-3072-C C08 1 EQC REFRIGERATED WORK TOP HoshizakiWR72B SELF CONTAINED 115 4 1/4 C09 2 EQC 18"WX30"D S/S WORK TABLE ALLSTRONGWT-3018-C C10 1 EQC EQC GAS 2 BURNER CHINESE WOK PandaPD-HKWR-2-1A 1/2"1-1/4"150 F.S. C11 2 EQC 30"WX42"D S/S WORK TABLE ALLSTRONGWT-4236-C SELF CONTAINED 115 3.3 1/3 C13 1 EQC EQC GAS 1 BURNER CHINESE WOK PandaPD-HKWR-1-1A 1/2"1-1/4"75 F.S. D01 3 EQC PLUMB 1-COMP SINKW/18" ONE SIDE DRAIN BOARD ALLSTRONGS1B1818-DR 1/2"1/2"F.S. D04 1 EQC PLUMB HIGH TEMPERATURE DISHWASHER ECOLABES-2000HT 1/2"F.S.230 75.2 3/4 1 D05 1 EQC EQC DISHABLESCLEAN STAIGHT ALLSTRONGDT48C-R D06 1 EQC 30"X48" S/S WORK TABLE ALLSTRONGWT-4830-C D07 1 EQC UNDERCOUNTER GLASS WASHER MOTAKDSP4DPS 3/4"F.S.208 3.6 20 F03 2 GC GC 32 GALLON COMMERCIAL TRASH CAN ULINEH-3687GR F02 1 GC GC HOOD FIRE EXTINGUISHER SYSTEM F01 1 GC GC RESTAURANT ORDER PRINTER EPSONTM-m30II 110 C14 1 EQC EQC ELEC. PASTA COCKER WINMOSTYS-ML 1/2"F.S.208 10 C12 1 EQC EQC ELEC. SIX BURNERS COCKER WINMOSTYS-BZF 1/2"F.S.208 10 P05 1 EQC GC S/S MOP SINK w/ CHEM. RACK& MOP HOLDER GSWSE2424FM 3/4"3/4"3"ANTI SIPHON FAUCET"CHICAGO" #897 P06 2 GC GC 2A10BC RATED FIRE EXTINGUISHER CLASS "K" FIRE EXTINGUISHER P07 1 OWN EC ELECTRONIC CASH REGISTER CASIOA-260 115 8 1 U01 1 EQC EQC S/S WALL SHELF 16"D @ 54" & 66" A.F.F.ALLSTRONGWMS-1660-C w/ 2" BACK & END P04 1 EQC GC AIR CURTAIN W/MICRO SWITCHEXISTING EQUIPMENT TO REMAIN MARSN236-1U 115 1/2 1 P01 1 EQC EQC GAS 75 GAL. WATER HEATER RHEEMG75-75 3/4"3/4"78 MOP 115 P02 3 EQC EQC 2-DOOR REACH IN REFRIGERATOR HoshizakiR2A-FS 115 5.2 2/3 P03 2 EQC EQC 2-DOOR REACH IN FREEZER HoshizakiF2A-FS 115 6.3 1/2 U02 5 EQC EQC S/S WALL SHELF 16"D @ 54" & 66" A.F.F.ALLSTRONGWMS-1636-C w/ 2" BACK & END U03 1 EQC EQC S/S WALL SHELF 16"D @ 54" & 66" A.F.F.ALLSTRONGWMS-16108-C w/ 2" BACK & END U04 2 EQC EQC S/S WALL SHELF 16"D @ 54" & 66" A.F.F.ALLSTRONGWMS-1672-C w/ 2" BACK & END U05 1 EQC EQC S/S WALL SHELF 16"D @ 54" & 66" A.F.F.ALLSTRONGWMS-1648-C w/ 2" BACK & END H01 1 EQC EQC 24'-0" L TYPE I HOOD CAPTIVE AIRSEE M SEE MECHANICAL HOOD DETAIL H02 1 EQC EQC 8'-0" L TYPE I HOOD CAPTIVE AIRSEE M SEE MECHANICAL HOOD DETAIL H03 1 EQC EQC 4'-0" L TYPE I I HOOD CAPTIVE AIRSEE M SEE MECHANICAL HOOD DETAIL H04 1 EQC EQC 3'-0" L TYPE I I HOOD CAPTIVE AIRSEE M SEE MECHANICAL HOOD DETAIL T07 1 EQC EQC Hand Dryer Action SalesDyson Water Softener Conditioner Everpure ICE MAKER, CUBE-STYLE Hoshizaki EQ U I P M E N T / F U R N I T U R E F L O O R P L A N EQ U I P M E N T S C H E D U L E A-4 GENERAL NOTES: ALL EQUIPMENT & INSTALLATION WILL MEET NATIONAL SANITATIONFOUNDATION (N.S.F.) STANDARD OR EQUIVALENT. ALL EQUIPMENT, INCLUDING SHELVING, MUST BE SUPPORTED BY SIX (6) INCH HIGH, EASILY CLEANABLE LEGS, COMMERCIAL CASTORS, OR COMPLETELYSEALED IN POSITION ON FOUR (4) INCH HIGH CONTINUOUSLY COVED BASE OR CONCRETE CURB TO FACILITATE EASE OF CLEANING. 1 2 Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518 EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 2 5 AR C A D I A , C A 9 1 0 0 7 7/18/2023 HEALTH CORRECTION BUILDING CORRECTION 1. EXTERIOR FIXED WINDOW (EXISTING) 2. EXISTING EMERGENCY/EXIT LIGHTING FIXTURE ON CEILING 3. POST SIGN: "MAXIMUM CAPACITY 46 PERSONS" 4. WHERE OUTDOOR AREAS ARE PROVIDED FOR SMOKING, SMOKING IS PROHIBITED WITHIN 25-FT OF BUILDING ENTRIES, OUT DOOR AIR INTAKES AND OPERABLE WINDOWS, AND INSIDE BUILDINGS; OR AS ENFORCED BY THE APPLICABLE ENFORCING AGENCY, WHICHEVER ARE MORE STRINGENT. 5. ALL DOORS ARE SELF-CLOSING, SEE DOOR SCHEDULE @ A-3 6. H.C. SEATING 7. PROVE A MIN. 6" HIGH SPLASHGUARD ON THE SIDE OF HAND SINK. THE SPLASHGUA RD MUST EXTEND OUT TO BE IN LINE WITH THE FRONT EDGE OF THE HAND SINK. 8. REMAIN EXISTING SIGN STATING "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" @ 1" MIN. HT LETTER. 9. PROVIDE BACKFLOW DEVICE /BACK-SIPHONAGE TO MOP SINK. 10. PROVIDE LIGHT SWITCH ACTIVATED EXHAUST FAN AT RESTROOMS EQUIPMENT FLOOR PLAN NOTES: CONTROLS & OPERATING MECHANISMS NOTES: 1. CLEAR FLOOR SPACE COMPLYING WITH SECTION 1118B.4 THAT ALLOW A FORWARD OR PARALLEL APPROACH BY A PERSON USING A WHEELCHAIRSHALL BE PROVIDED AT CONTROLS, DISPENSERS, RECEPTACLES, ANDOTHER OPERABLE EQUIPMENT. 2. CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PUNCHING, ORTWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS. EQUIPMENT FLOOR PLAN SCALE: 1/4"=1'-0"NOTES: FOR ALL REMODEL CONSTRUCTION, CONTRACTOR MUST FIELD VERIFY BEFORE CONSTRUCTIONS. 1 ACCESSIBLE TABLE DETAIL SCALE: 1/2"=1'-0" 1 1 2 8 6 6 6 ADA RESTROOM SEE A-6 FOR DETAIL 9 1 1 HEALTH DEPARTMENT NOTE: ALL EQUIPMENT, INCLUDING SHELVING, MUST BE SUPPORTED BY SIX(6) INCH HIGH, EASILY CLEANABLE LEGS, COMMERCIAL CASTORS, OR COMPLETELY SEALED IN POSITION ON A FOUR(4) INCH CONTINUOUSLY COVED BASE CONCRETE CURB TO FACILITATE EASE OF CLEANING. 1 1010 LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED 14 ' - 5 " 1' - 3 " 3' - 4 " 9' - 1 0 " 4' - 7 " 27'-0" 15'-5"6'-2"5'-5" 3' - 4 12" 6' - 5 12" BLACK METAL GLASS DOORS CLEAN GLASSLEDSIGN CLEAN GLASS BLACK METAL STORE FRONT DOOR LOGO灯箱示意 7' - 1 12" 3' - 5 12" 8'- 2 12" 5'-7"10'-7"5'-11"7'-10"29'-1112" BLACK METAL LED DISPLAY SCREEN METAL HANDRAIL POST METAL HANDRAIL DISPLAY SIGN 9' - 1 0 " BLACK PLASTIC LAMINATEGLASS DOORS CLEAN GLASSSTORE FRONT DOORCLEAN GLASS 27'-0"15'-5"6'-2"5'-5" 3' - 5 12" LED LIGHTING LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LEDLED LED LEDLEDLEDLED LEDLEDLEDLED LEDLEDLEDLED LEDLEDLEDLEDLEDLEDLED LEDLEDLEDLED LEDLED LED LEDLEDLEDLED LEDLEDLEDLED LEDLEDLEDLED LEDLEDLEDLEDLEDLEDLED LEDLEDLEDLED LEDLED 7'-012"22'-912"5'-012" 34'-11" 9' - 1 0 " 2' - 1 1 12" 3' - 1 12" 3' - 1 0 " LED SCREEN LED SCREEN 插座 网线插座 LED SCREEN 插座插座 插座 网线 网线 LED LED LED LED LED LED LED LED LED LED 9' - 1 0 " 3' - 5 12"5' - 2 12" 2'- 1 0 12" 3'-8"14'-312"3'-8" BLACK PLASTIC LAMINATE PAINTFINISH CABINET LAMINATE FINISH CABINET LAMINATE LED CEILING SOFIT 1'-0"5'-9"1'-0"7'-512" 4" 9' - 1 0 " 3'- 5 12" 212" 13 ' - 6 " 5'-11" 4" 3'- 1 12" 412"412" BLACK METAL EXISTING GLASS STORE FRONT SIGN EXISTING STORE FRONT FINISH 3'-8" METAL FENCE FOR EXISTINGOUTDOOR SEATING DI N I N G A R E A E L E V A T I O N S EX T E R I O R E L E V A T I O N S A-5 Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518 EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 2 5 AR C A D I A , C A 9 1 0 0 7 7/18/2023 HEALTH CORRECTION BUILDING CORRECTION SCALE: 1/4" = 1'-0" Elevation 1 SCALE: 1/4" = 1'-0" Out Door Patio Elevation 2 SCALE: 1/4" = 1'-0" Out Door Patio Elevation 3 SCALE: 1/4" = 1'-0" Elevation 4 SCALE: 1/4" = 1'-0" Elevation 6 SCALE: 1/4" = 1'-0" Elevation 5 NEW STORE FRONT 3D IMAGE EXISTING STORE FRONT 18 " M I N . 24 " M I N . 2' - 6 " 4'-0"LAVATORYMAX. 6-1/2" DEEP 2'-0" MEN'SRESTROOM 12"MAX.42" min. 54" min. 16 " ~ 1 8 " 7' - 1 1 " 5'-3" 5'-0" MIN. DIA. CLR.5'-0" MIN. DIA. CLR.WOMEN'SRESTROOM 18 " M I N . 24 " M I N . 2'-0" 12"MAX.42" min. 54" min. 5' - 1 0 " 5'-2" 3 5 6 7 8 7'-8" 2 1 4 2' - 6 " 4'-0" 3' - 0 " 9" M I N . 27 " M I N . 29 " M I N . 34 " M A X . 40 " M A X . T O R E F L E C T I V E S U R F A C E 6" MAX. 19"(17" MIN.) 8" MAX. GRAB BAR 7"-9"19 " 12" 24"MIN. 33 " 18 "40 " M A X I M U M 2' 1 0 " M I N . MIRRORWALL TILES 14 " ~ 1 7 " T. F . F . 1'-6"40 " M A X . 19 " 33 " 18" MIN. 8' - 2 " GRAB BARWALL TILES COVE BASE PAPER TOWEL COVE BASE 2' - 1 0 " M I N . TY P . UNISEX SIGN(ELEVATION) 14" THICK, 12" DIA. CIRCLE GEOMETRICSYMBOL PICTOGRAM IDENTIFICATION SIGNOR ROOM IDENTIFICATION NOTES: RAISED LETTERS, BRAILLE CHARACTERS AND PICTOGRAM SYMBOL TO BE RAISED 1/32" MIN. SHALL BE SANS SERIF UPPERCASE ACCOMPANIED BY GRADE 2 BRAILLE. RAISED CHARACTERS SHALL BE A MIN. 5/8" TO 2" MAX HEIGHT, WIDTH TO HEIGHT RATIO BETWEEN 3:5 AND 1:1 AND STROKE WIDTH TO A MINIMUM OF 6"X6" CHARACTERS AND SYMBOLS SHALL CONTRAST WITH PICTOGRAM ACCOMPANIED BY EQUIVALENT VERBAL DESCRIPTION DIRECTLY BELOW FINISHED FLOOR NOTES: CHARACTERS, SYMBOLS AND THEIR BACKGROUND SHALL HAVE A NON GLARE FINISH AND SHALL CONTRAST WITH THEIR BACKGROUND, EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. MEN NOT INPICTOGRAMFIELD FIGURE 11B-703.6.1PICTOGRAM FIELD MEN WALL TILES 34 " ~ 4 4 " T Y P . COVE BASE 19 " 33 " 24" MIN. 7"~9"40 " M A X . 2' 1 0 " M I N . INSULATED PAD COVER MIRRORWALL TILES 1'-6" 19 " 33 " 18" MIN. 8' - 2 " WALL TILES PAPER TOWEL COVE BASE DOOR WALL TILES COVE BASE 34 " ~ 4 4 " T Y P . COVE BASE SOUP DISP. 2' - 1 0 " M I N . TY P . WALL TILESPAPER TOWEL COVE BASE 8' - 2 " RE S T R O O M D E T A I L A-6 Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518 EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 2 5 AR C A D I A , C A 9 1 0 0 7 7/18/2023 HEALTH CORRECTION BUILDING CORRECTION 1. 2. FLOORING UNDER EQUIPMENT AND AT THE BASE COVES SHALL BE COMPLETELY SMOOTH. THE PAINT USED ON WALLS AND CEILINGS OF ALL KITCHEN, FOODPREPARATION, WORK, AND STORAGE AREAS WILL BE A GLOSS OR SEMI-GLOSS ENAMEL. FINISH MATERIAL SHALL BE LIGHT INCOLOR WITH A REFLECTANCE VALUE OF 70% OR GREATER. MUST BE SMOOTH EASILY CLEANABLE. RESTROOM FINISH SCHEDULE NOTES: 3.TOILET AND BATHING ROOM FLOORS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE THAT EXTENDS UPWARD ONTOTHE WALLS AT LEAST 4-INCH. 1. STRUCTURAL STRENGTH OF GRAB BARS, TUB AND SHOWER SEATS,FASTENERS, AND MOUNTING DEVICES SHALL MEET THE FOLLOWING SPECIFICATIONS:a. BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THE MAXIMUM BENDING MOMENT FROM THE APPLICATION OF A250-IBPOINT LOAD SHALL BE LESS THAN THE ALLOWABLE STRESS FOR THE MATERIAL OF THE GRAB BAR OR SEAT. b. SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THEAPPLICATION OF A 250-LB POINT LOAD SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS FOR THE MATERIAL OF THE GRABBAR OR SEAT, AND ITS MOUNTING BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY RESTRAINED, THENDIRECT AND TORSIONAL SHEAR STRESSES SHALL NOT EXCEED THE ALLOWABLE SHEAR STRESS. c. SHEAR FORCE INDUCED IN FASTENER OR MOUNTING DEVICESFROM THE APPLICATION OF A 250-LB POINT LOAD SHALL BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER THE FASTENEROR MOUNTING DEVICE OR THE SUPPORTING STRUCTURE, WHICHEVER HAS THE SMALLER ALLOWABLE LOAD.d. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF A 250-LB POINT LOAD, PLUS THE MAXIMUM MOMENT FROM THE APPLICATION OF A 250-LB POINT LOAD, SHALL BELESS THAN THE ALLOWABLE WITHDRAWAL LOAD BETWEEN THE FASTENER AND SUPPORTING STRUCTURE.e. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. 2. THE GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE FREE OF ANY SHARP OR ABRASIVE ELEMENTS. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8". RESTROOM GRAB BARS NOTES: SCALE: 1/2" = 1'-0" H.C. LAVATORY /GRAB BAR DETAIL SCALE: N.I.S. GREEN CODE NOTES: ENLARGED RESTROOMS EXHAUST SYSTEM CAPABLE OF PROVIDING A MINIMUM 75 CFM.(TYP.) 1. FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND ANDSHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST AND SHALL BE MOUNTED NO MORE THAN 44 INCHESABOVE FLOOR. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBF. ELECTRONIC AUTOMATICFLUSHING CONTROLS ARE ACCEPTABLE AND PREFERABLE. [CBC 1115B.4.2] 2. HOT WATER AND DRAIN PIPES EXPOSED UNDER SINKS SHALL BEINSULATED OR OTHERWISE CONFIGURED SO AS TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR TO ABRASIVESURFACES UNDER SINKS. 3. SELF-CLOSING FAUCET CONTROL VALVES ARE ALLOWED IF THEFAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. 4. CONTROLS FOR WATER CLOSET FLUSH VALVES SHALL BE MOUNTED ON THE WIDE OF TOILET AREAS. AUTOMATIC SPRING TOLIFTED POSITION SEATS ARE NOT ALLOWED. 5. THE ENTRANCE DOOR SHALL CONTAIN A PRIVACY LATCH.6. THE WATER CLOSET COMPARTMENT SHALL BE EQUIPPED WITH A DOOR THAT HAS AN AUTOMATIC-CLOSING DEVICE, AND SHALL HAVE A CLEAR, UNOBSTRUCTED OPENING WIDTH OF 32" WHENLOCATED AT THE END AND 34" WHEN LOCATED AT THE SIDE WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITSCLOSED POSITION. 7. THE INSIDE AND OUT SIDE OF THE COMPARTMENT DOOR SHALL BEEQUIPPED WITH A LOOP OF U-SHAPED HANDLE IMMEDIATELY BELOW THE LATCH. THE LATCH SHALL BE FLIP-OVER STYLE, SLIDING, OR OTHER HARDWARE NOT REQUIRING THE USER TOGRASP OR TWIST. 8. FOR VENTILATED SPACES IN BUILDINGS, THE SPACES SHALL MEETTHE MIN. REQUIREMENTS OF SECTION 121 OF THE ENERGY CODE AND DIVISION I, CHAPTER 4 OF CCR, TITLE 8. PER TABLE AT T.2 HEALTH PLAN CHECK NOTE: 1 PROVIDE LIGHT SWITCH ACTIVATED EXHAUST FAN INSIDE RESTROOM. RESTROOM NOTES: 1 1. STRUCTURAL STRENGTH OF GRAB BARS, TUB ANDSHOWER SEATS, FASTENERS, AND MOUNTING DEVICES SHALL MEET THE FOLLOWING SPECIFICATIONS:a. BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THE MAXIMUM BENDING MOMENTFROM THE APPLICATION OF A250-IB POINT LOAD SHALL BE LESS THAN THE ALLOWABLE STRESS FOR THE MATERIAL OF THE GRAB BAR OR SEAT.b. SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE APPLICATION OF A 250-LB POINT LOADSHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS FOR THE MATERIAL OF THE GRAB BAR ORSEAT, AND ITS MOUNTING BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT AND TORSIONALSHEAR STRESSES SHALL NOT EXCEED THE ALLOWABLE SHEAR STRESS.c. SHEAR FORCE INDUCED IN FASTENER OR MOUNTING DEVICES FROM THE APPLICATION OF A 250-LB POINT LOAD SHALL BE LESS THAN THEALLOWABLE LATERAL LOAD OF EITHER THE FASTENER OR MOUNTING DEVICE OR THESUPPORTING STRUCTURE, WHICHEVER HAS THE SMALLER ALLOWABLE LOAD. d. TENSILE FORCE INDUCED IN A FASTENER BY ADIRECT TENSION FORCE OF A 250-LB POINT LOAD, PLUS THE MAXIMUM MOMENT FROM THEAPPLICATION OF A 250-LB POINT LOAD, SHALL BE LESS THAN THE ALLOWABLE WITHDRAWAL LOADBETWEEN THE FASTENER AND SUPPORTING STRUCTURE. e. GRAB BARS SHALL NOT ROTATE WITHIN THEIRFITTINGS. 2. THE GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE FREE OF ANY SHARP ORABRASIVE ELEMENTS. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8". DOOR SIGN DETAIL SCALE: N.I.S. SCALE: 1/2" = 1'-0" Elevation 1 1 SCALE: 1/2" = 1'-0" Elevation 2 SCALE: 1/2" = 1'-0" Elevation 3 SCALE: 1/2" = 1'-0" Elevation 4 SCALE: 1/2" = 1'-0" Elevation 5 SCALE: 1/2" = 1'-0" Elevation 6 SCALE: 1/2" = 1'-0" Elevation 7 SCALE: 1/2" = 1'-0" Elevation 8 LOW PARTITION 1 SILLC EQ. PER SCHEDULE EQ. DOOR WIDTH AS TYPE 'H' - SIDELIGHT GLAZ. PART. SEE PLAN EQ. JAMBB JAMBD HEADA ELEVATIONF 4 36SUSPENDED CEILING DETAIL FOR SIZE ICC-ES REPORT: ESR: 2673 9SCALE N.I.S. WALL BASE DETAIL EXISTING FLOOR FINISH PARTITION DETAIL PROVIDE 5/8" TYPE "X" GYPSUM BOARD ONEACH SIDE. SECURE TO THE METAL STUDSWITH NO. 6 BUGLE HEAD SCREWS @ 8" O.C. WALL BASE. SEE FINISH PLANS TAPE AND FILL ALL JOINTS. METAL SCREW AT EA. STUD TOP RUNNER CHANNEL SECURED TODIAGONAL BRACES WITH #10 SHT PROVIDE METAL STUD DIAGONAL BRACING OF EACH DOOR. STAGGER BRACING ANDSECURE TO THE TOP RUNNER CHANNEL WITH @ 4'-0" ON CENTER AND AT THE STRIKE SIDE TWO #10 S-12 PAN HEAD SCREWS SECURE BRACE TO STRUCTURE ABOVE (ICC:ESR-2174) ESR-2174 ICC:ESR-3059 DRY WALL CEILINGSEE DETAIL AT #9 0.177" DIA. HILTI SHOT PINS WITH WASHERS WITH 1716"EMBEDMENT AT 24" O.C. RESEARCH REPORT: RR 25921 (CSI #05 05 23) 25 GA. METAL STUDS @16" O.C.(HEIGHT TO 10'-0") MANUFACTURE FOR STEE STUDS: CRACO MANUFACTURING, INC. 1122 JOHNSON ROAD YORK, SOUTH CAROLINA29745 ESR-3957P 2SCALE N.I.S. SCHEDULED FINISH FLOORING & BASE 20 GA BOTTOM TRACK TO MATCH STUD SIZE W/ .145 DIA. X 1 14" POWER-DRIVEN PIN FASTERNERS AT 24" O.C. PER I.C.C # ESR-1799. ATTACH STUDS TO TRACK W/ #8 S.M.S. EACH SIDE. EXISTING WALL 2 12" OR AS REQUIRED. 20 GA. 16" O.C. ICC-ER 4943P 58" TYPE "X" GYP. BD. PROVIDEGREENBOARD AT ALL WET LOCATIONS. TOP TRACK SECURED TO WALL BRACE W/ (2)#8 S.M.S. DRY WALL CEILING BRACINE WITH 2 12", 20 GA.,16" O.C. MAX. ABOVE CLG. AT 45° ANGLE. EXISTING TRUSSES FURRED OUT PARTITION 1 HOUR RATED WALL DETAIL EXISTING ROOF STRUCTURAL PROVIDE SOUND BATT INSULATIONIN ALL CAVITIES AND VOIDS WALL BASE. SEE FINISH PLANS FINISH FLOOR LINE SLIPTRACK SYSTEM, SLP-TRK SECURE BRACE TO STRUCTURE ABOVEESR-2174 PROVIDE 2 LAYERS 5/8" TYPE "X" GYPSUMBOARD ON EACH SIDE. SECURE TO THEMETAL STUDS WITH NO. 6 BUGLE HEAD SCREWS @ 8" O.C. TAPE AND FILL ALL JOINTS. PROVIDE BOTTOM RUNNER CHANNEL SECURED TO THE CONCRETE FLOOR WITHAPPROVED FASTENERS PER CODE 4", 20 GA. METAL I.C. STUDS AT 16" O.C.PER ICC-ER 4943P. UL DESIGN U419OR U465 #8 WAFERHEAD SCREW 4"X58" TRYE X DRYWALL RIP 1.5X1.5" METAL ANGLE 5SCALE N.I.S. 7 AT STUD PENETATING CEILING BOX BRACE B C C C 12" GA P DECK II TO WALL 12" GA P 12" TOP CONNECTION TO JOISTSAT PATITION STUD CONNECTION DETAIL N.I.S. DECK I TO WALL SILL 8 SCALE N.I.S. SCALE N.I.S. SCALE N.I.S. SCALE N.I.S. SCALE N.I.S. SCALE EXISTING TRUSSES FIN . C E I L ' G H T 38" AT TWO ADJACENT WALLS OR 34"AT ALL FOUR WALLS. SEE NOTE 2. 45°45° 12 GA. BRACING WIRE WITHMIN. 4 TIGHT TURNS IN 1-1/2" AT BOTH ENDS OF WIRE(TYP.)AT EA. VERTICAL STRUT. 4'-0" (T Y P E . ) 2'-0" 8'-6" 2" X 20 GA. 3" X 16 GA. 11'-6" 17'-3" 23'-3" 14'-6" SIZE SCHEDULE(BASED ON L/R<200)COMPRESSION PIPE STRUT 1/2" X 22 GA. 3/4" X 22 GA. 1" X 20 GA. MAX. HEIGHT 3'-0" 4'-0" 6'-0" 7'-0" SIZE 2" OVERSIZE RING, SLEEVE OR ADAPTER THROUGH THECEILING TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1"IN ALL HORIZONTAL DIRECTIONS IS PERMITTED TO BEPROVIDED AT THE TOP OF THE SPRINKLER HEADEXTENSIONS. PROVIDE RIGID BRACING AT EACH SPRINKLER HEADTO LIMIT LATERAL DEFECTION FIRE SPRINKLER HEAD PIPING CDNN. FOR 100 #, POWER ACTUATED FASTENERS NOT ALLOWEDUNLESS APPROVED LISTING (SUCH AS ICC ES REPORT)IS PROVIDED 12 GA. WIRE MIN. W/NO BENDS. CONN. W/ 3 TURNS WITH 3" AT ENDS.PLUMB WITHIN 1:6 SLOP OR PROVIDE COUNTER SLOPECONFIGURATION DET.2 HEAVY DUTY T-BAR SYSTEM 2" MIN.FASTENED TO WALL 3/4" MIN.FREE TO SLIDE ATNON-FASTENED WALL 6" MAX.THEN 48" O.C.E.W. 1 6MAX.SLOPE DETAIL 1-TYPICAL CONNECTIONS DETAIL 7-FIRE SPRINKLER HEAD TYPICAL SUSPENDED CEILING VERTICAL AND LATERAL SUPPORT: DETAIL 2-COUNTER SLOPE OPTION 45°Suspended ceiling Counter sloped wires ea. side of supported t-barin lieu of vert. wires-installed at same spacingand conn. req'ts. AS DETAIL 1 STRUCTURE ABOVE 12 GA. WIRE (MAY BE SLACK). PROVIDE 2 WIRES IF FIXTUREWEIGHT IS>10 LBS. PROVIDE DIRECT SUPPORT FROMSTRUCTURE IF WEIGHT>56 LBS. 2'X4' RECESSED LIGHT FIXTURE SUSPENDED ACOUSTIC CEILING CONDUIT ANDCONNECTOR FLEX PLATE #8x1/4" SHEET METAL SCREW (OR APPROVED FASTENER) DETAIL 5-LIGHTING FIXTURE Notes:1. Vertical strut: A strut fastened to the main runner shall be extended to and fastened to the structuralmembers supporting the roof or floor above. The strut shall be adequate to resist the vertical. 2. These horizontal restraint points shall be placed at 12 feet on center in both directions with the first pointwithin 6 feet from the wall.3. Perimeter hangers shall be placed in both directions within 8 inches of the wall. RIGIDVERTICALSTRUT VERTICAL STRUT AT 12' O.C. EACHWAY WITH FIRST POINT TO BEWITHIN 6' FROM EACH WALLFASTEDED TO MAIN MAIN RUNNER &STRUCTURE ABOVE PER ASCE-713.5.6.2.2 WALL WA L L 2'-0" 12 GA. PERIMETERHANGER @ 4' O.C. Alternate: Furnish & install new acoustical ceiling system: armstrong 2' x 4' ultima, tile will be supported by donn suprafine 9/16 spline system. 1. BRACING WIRES SECURED TO MAIN RUNNERS WITHIN 2" OF THE CROSS RUNNER INTERSECTION AND SPLAYED 90" FROM EACH OTHER AT AN ANGLE NOT EXCEEDING 45°FROM THE PLANE OF THE CEILING.2. FOR ROOMS WITH SPAN IN EITHER DIRECTION LESS THAN 25', MAIN RUNNERS AND CROSS RUNNERS MAY BE ATTACHED TO THE PERIMETER OF TWO ADJACENT WALLS WITH 38" CLEARANCE BETWEEN THE RUNNERS AND THE OTHER TWO WALLS. WHERE SPAN OF THECEILING SYSTEM BETWEEN PERIMETER WALLS EXCEED 25' IN BOTH DIRECTION, A MINIMUMWALL ANGLE SIZE OF ATLERST 2" HORIZONTAL LEG SHALL BE USED AT PERIMETER WALLS AND INTERIOR FULL HEIGHT PARTITION. THE FIRST TILE SHALL BE 34" CLEAR FROM WALLSURFACE.3. WHEN THE DISTANCE BETWEEN THE STRUCTURAL DECK AND THE CEILING EXCEEDS 4',THE SPACING OF THE VERTICAL HANGERS SHALL NOT EXCEED 2' O.C. ALONG THE ENTIRE LENGTH OF THE MEANS OF EGRESS SERVICING AN OCCUPANT LOAD OF 30 OR MORE, AND AT LOBBIES ACCESSORY TO GROUP A OCCUPANCIES. NOTES: 38" MIN. CLR CROSS OR MAIN RUNNER ACOUSTICAL TILE CEILING ON SUSPENDEDGRID SYSTEM 34" AT TWO ADJACENT WALLS OR 34"AT ALL FOUR WALLS. SEE NOTE 2. SECTION THRU ROOM REFLECTED CEILING PLAN Typical (2) per fixture 12 gauge hanger wiresplayed at 45° to fixture typical @ (2) corners.wire ties to have (4) turns within 1 - 1/2" typical 1/4" Bolt or other approved fastener with nut andlock-washer. typ. (2)per fixture. Fasten fixture to t-bar with (2) metal screws oneach 48" side LIGHTING FIXTURE BRACING 12 GA. VERTICAL HANGERWIRE AT 4'-0" EACH WAY WITHMIN. 3 TIGHT TURNS IN 1-1/2"AT BOTH ENDS OF WIRE(TYP.) 2" NO. 12 GA. MIN. VERTICALHANGER WIRE SEE NOTE 3. CROSS RUNNERS MAIN RUNNERS 12 GA. VERTICAL HANGERWIRE AT 4'-0" EACH WAY WITH MIN. 3 TIGHT TURNS IN 1-1/2"AT BOTH ENDS OF WIRE(TYP.) SUSPENDED CEILINGS AND LIGHTING SYSTEMS: B. MINIMUM INSTALLATION REQUIREMENTS: 1. Vertical Support a. Hanger wires supporting a maximum tributary ceiling area of 16 square feet shall be a minimum of 12 gauge in diameter. The size of wiressupporting a tributary ceiling area of greater than 16 square feet shall be substantiated by design calculations. b. Hanger attachment devices used in ceiling systems not exceeding four pounds per square foot shall be capable of supporting a minimumallowable load of 100 pounds. Hanger attachment devices used in ceiling systems exceeding fourpounds per square foot shall be capable of supporting the design load and shall be substantiated by design calculations.c. Hangers shall be plumb and shall not attach to or bend around interfering duct pipes or similar obstructions. If hangers must be splayed more thanone horizontal to six vertical the resulting horizontal force shall be offset by bracing, counter-splaying or other acceptable means andsubstantiated by design calculations. d.Perimeter Hangers. The terminal end of each cross runner or main runner shall be independently supported and within eight inches of a wall. 2. Lateral Support Lateral support for the ceiling system may be provided by four wires of minimumNo. 12 gauge splayed in four directions 90 degrees apart and connected to the main runner within two inches of the cross runner and to the structure above at anangle not exceeding 45 degrees from the plane of the ceiling. These lateral support points shall be placed 12 feet o.c. in each direction with the first pointwithin four feet from each wall. 3. Attachment of Members to the Perimeter Allowance shall be made for lateral movement of the system. Main runners andcross runners may be attached at two adjacent walls with clearance between the wall and the runners maintained at the other two walls. 4. Lighting Fixture and Air Diffuser Supports Lighting fixtures and air diffusers shall be supported directly by wires to the structure above. EXCEPTIONS: a. Recessed lighting fixtures not over 56 pounds in weight and suspended and independently hung fixtures not over 20 pounds in weight may be supported and attached directly to the ceiling system runners by a positive attachment such asscrews or bolts. b. Air diffusers which weigh not more than 20 pounds and which receive notributary loading from duct work may be positively attached to and supported by the ceiling runners. 5. Perimeter Members A minimum wall angle size of at least a two inch (51 mm) horizontal leg shall be used at perimeter walls and interior full height partitions. The first ceiling tile shallmaintain 3/4- inch (19 mm) clear from the finish wall surface. An equivalent alternative detail that will provide sufficient movement due to anticipated lateralbuilding displacement may be used in lieu of the long leg angle subject to the approval of the Superintendent of Building. Application: This provision shall be required only when the span of the proposed suspended ceiling system between perimeter walls exceeds 25 feet in both directions.Perimeter walls shall be considered as those existing/proposed interior partitions that are laterally braced as required by Section 1613.7.1 of the Los Angeles CityBuilding Code. 6. Bracing at Discontinuity Positive bracing to the structure shall be provided at the changes in the ceilingplane elevation or at discontinuities in the ceiling grid system. 7. Support for Wiring Systems Electrical wiring systems, including cable trays, conduits, junction boxes, and other appurtenances shall be independently supported and independently bracedfrom the structure. 8. Sprinkler Heads All sprinkler heads (drops) except floor-ceiling or roof-ceiling fire-resistiveassemblies, shall have a 2 inch (50 mm) oversize ring, sleeve, or adaptor through the ceiling tile to allow for free movement of at least 1 inch (25 mm) in allhorizontal directions. Alternatively, a swing joint that can accommodate 1 in. (25 mm) of ceilingmovement in all horizontal directions is permitted to be provided at the top of the sprinkler head extension. Sprinkler heads penetrating floor-ceiling or roof-ceiling fire-resistive assemblies shall comply with Section 712.3.1 of the Los Angeles City Building Code. A. SUSPENDED CEILINGS AND LIGHTING SYSTEMS Suspended ceiling systems are ceiling assemblies used to supportacoustical lay-in panels or tiles. Such systems shall comply with Section 808 and 2506 of the Building Code, including Section 13.5.6 of the ASCE 7-05 Standard, ASTM C 635. ASTM C 636, and CISCA. This prescriptive design may be used for suspended ceiling and lighting systems that are maximum 4 feet below the structural deck and weigh no more than 4 pounds per square foot. C. SPECIAL REQUIREMENT FOR MEANS OF EGRESS 1. General Ceiling suspension systems shall be connected and braced directly to the structure at the means of egress serving an occupant load of 30 or more and at lobbies accessory to Group A Occupancies. Spacing of vertical hangers shall not exceed 2 feet (610mm) oncenter along the entire length of the means of egress or lobby. Application: These provisions shall be required only when the distance between the structural deck and the suspended ceilingexceeds 4 feet. 2. Assembly Device All lay-in panels shall be secured to the suspension system with two hold-down clips minimum for each tile within a 4-foot (1219 mm)radius of the exit lights and exit signs. Application: This requirement shall apply only in fire-rated exit corridors and within A, E, and M occupancies. For purposes of this Section, exitstrobe lights shall not be considered exit signs. 3. Emergency Systems Independent supports and braces shall be provided for light fixtures required for exit illumination. Power supply for exit illumination shall comply with the requirement of Section 1011.5.3 of the Los Angeles City Building Code. 4. Supports for Appendage Separate support from the structure shall be provided for allappendages, such as light fixtures, air diffusers, exit signs and similar elements. SE E NO T E S 3 112" X 20 GA. 134" X 20 GA. 212" X 18 GA. 312" X 16 GA. TYPICAL SUSPENDED CEILING VERTICAL & LATERAL SUPPORT BASED UPON ICC ES EVALUATIONSERVICE REPORT NO. ESR-1308 WORTHINGTON ARMSTRONG VENTURE (WAVE)101 LINDEN WOOD DR, SUITE 350MALVERN, PA 19355ATTN: JOSEPH J. KELLY(610)277-1218 FIRE-AND NONFIRE-RESISTANCE-RATED SUSPENDEDCEIING FRAMING SYSTEMS NON-BEARING WALLCONNECTION DETAIL DE T A I L S Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 1 AR C A D I A , C A 9 1 0 0 7 6/5/2023 A-7 Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 2 5 AR C A D I A , C A 9 1 0 0 7 7/18/2023 HEALTH CORRECTION BUILDING CORRECTION 20 2 2 C A L G R E E N C O D E G-1 Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 2 5 AR C A D I A , C A 9 1 0 0 7 7/18/2023 HEALTH CORRECTION BUILDING CORRECTION 20 2 2 C A L G R E E N C O D E G-2 Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 2 5 AR C A D I A , C A 9 1 0 0 7 7/18/2023 HEALTH CORRECTION BUILDING CORRECTION 20 2 2 C A L G R E E N C O D E G-3