HomeMy WebLinkAbout400 S Baldwin Ave - 2023 - Taier Mechanical & PlumbingM-1
ME
C
H
A
N
I
C
A
L
L
E
G
E
N
D
,
NO
T
E
,
&
S
C
H
E
D
U
L
E
NO.
EQUIPMENT SCHEDULE
DESCRIPTION
Job No.
Sheet No.
Plot Date
Scale
Job Begin
JO
B
N
A
M
E
4/4/2023
1
2
REVISIONS:
SH
E
E
T
T
I
T
L
E
:
MONTEREY PARK, CA 91754
Tel: (626) 476-0518
EMAIL: TIANMUS@GMAIL.COM
Interior Design
3
4
TA
I
E
R
R
E
S
T
A
U
R
A
N
T
T
.
I
.
40
0
S
O
U
T
H
B
A
L
D
W
I
N
A
V
E
.
,
S
U
I
T
E
2
3
1
AR
C
A
D
I
A
,
C
A
9
1
0
0
7
646 Armitos Place Diamond Bar, CA 91765
T: 909.569.2586 Email: bkengineers88@gmail.com
B CONSULTING ENGINEERS INCK
CONDENSATE DRAIN
DN. DOWN
SUPPLY AIR DUCT
RETURN AIR DUCT
EXHAUST AIR DUCT
OUTSIDE AIR DUCT
TRANSITION - RECTANGULAR TO RECT-
TRANSITION - RECTANGULAR TO ROUND
ELBOW W/TURNING VANE
LINED DUCT, DUCT SIZE WITH L FOR
RISE IN DIRECTION OF AIRFLOW
DROP IN DIRECTION OF AIRFLOW
DUCT ENCLOSURE IN GYPSUM BOARD FOR
2 HOURS RATING
FLEXIBLE DUCT
SUPPLY AIR DUCT - SECTION
RETURN, EXHAUST, OR OUTSIDE AIR DUCT
ROUND DUCT OR STACK - SECTION
12"X 12" NECK PERFORATED CEILING
6"X 6" PERFORATED CEILING REGISTER,
DIFFUSER, 360 CFM
OAOA
T
150
CD
12X12CD
6X6R
360
150 CFM
-SECTION
THERMOSTAT WITH AUTOMATIC CHANGE-OVER
D D
R R
6X6L (L)SINGLE LINE
ANGULAR
GENERAL NOTES
SINGLE
SYMBOL
DOUBLE
RA
EAD
SA
ABBREVI-
RA
EAD
SA
ATION
LEGEND
& VENTED LOCKABLE CLEAR COVER
1.THE DRAWINGS, SPECIFICATIONS AND GENERAL NOTES DESCRIBE THE
RECOMMENDED SCOPE OF WORK AND THE DOCUMENTS SHALL BE USED FOR THE
PURPOSE OF BIDDING, BUILDINGS DEPARTMENT REVIEW, AND TO SECURE THE
NECESSARY CONSTRUCTION PERMIT ONLY. CONTRACTOR SHALL PROVIDE
CONSTRUCTION DRAWINGS AND OBTAIN WRITTEN APPROVAL OF ALL INSPECTION
AUTHORIZED GOVERNMENTAL AGENCIES AND UTILITY COMPANIES PRIOR TO START
OF AFFECTED WORK.
2.ALL MECHANICAL WORK SHALL COMPLY WITH LOCAL APPLICABLE CODE AND 2022
CALIFORNIA MECHANICAL CODE.
3.COORDINATE ALL MECHANICAL WORK W/ARCHITECTURAL, ELECTRICAL
STRUCTURAL, SUBCONTRACTOR & OTHER TRADES TO AVOID INTERFERENCES.
4.COORDINATE LOCATIONS OF OPENING THROUGH FLOOR, WALL & ROOF
W/ARCHITECTURAL, ELECTRICAL & STRUCTURAL DRAWINGS.
5.SEAL & TAPE ALL OPENINGS IN DUCTWORK AIRTIGHT AFTER TESTING.
6.ALL SIZES FOR DUCT, GRILLE, REGISTER, DIFFUSER & LOUVER SHALL BE IN INCHES.
7.CHECK & VERIFY ALL FIELD CONDITIONS & ACTUAL DIMENSIONS BEFORE PREPARING
SHOP DRAWINGS & BEGINNING INSTALLATION NOTIFY ARCHITECT IMMEDIATELY OF
AND ALL DISCREPANCIES.
8.TEST & BALANCE ALL HVAC SYSTEM ACCORDING TO CFM INDICATED ON PLANS.
9.ALL APPLIANCE AND PLUMBING VENTS SHALL BE AT LEAST TEN (10) FEET IN A
HORIZONTAL DIRECTION, OR THREE (3) FEET ABOVE THE OUTSIDE-AIR INTAKES FOR
HVAC UNITS.
10.FACTORY-MADE FLEXIBLE DUCT & DUCT CONNECTOR TO BE U. L. 181 LISTED, &
MAXIMUM 5'-0".
11.GREASE HOOD EXHAUST DUCT SHALL SLOPE NOT LESS THAN 1/4" PER LINEAR FOOT
TOWARD THE HOOD SO THAT GREASE CANNOT BECOME POCKETED IN ANY PORTION
OF EXHAUST DUCT.
12.PROVIDE CLEANOUT OPENING WITH TIGHT-FITTING DOOR IN GREASE DUCT AND
FIRED RATED ENCLOSURE MATERIAL & CONSTRUCTION SHALL COMPLY WITH
CHAPTER 5 OF CMC CURRENT EDITION.
GENERAL SEISMIC NOTES
ALL BRACING OF DUCTS AND PIPING SHALL BE INSTALLED IN ACCORDANCE WITH SMACNA GUIDELINES AS
APPROVED BY CITY.
WHERE BRACING DETAILS ARE NOT SHOWN ON THE DRAWINGS OR IN THE GUIDELINES, THE FIELD INSTALLATION
SHALL BE SUBJECT TO THE APPROVAL OF THE ARCHITECT, MECHANICAL ENGINEER AND THE FIELD INSPECTOR.
A COPY OF THE GUIDELINES PUBLISHED BY SMACNA AND APPROVED BY CITY SHALL BE PROVIDED BY THE
CONTRACTOR AND KEPT ON THE JOB AT ALL TIMES.
THE SEISMIC ANCHORAGE OF MECHANICAL AND ELECTRICAL EQUIPMENT SHALL CONFORM TO C.C.R. TITLE 24,
SECTION 1630A AND TABLE 16A-K.3. ANCHORAGE DETAILS FOR ROOF/FLOOR MOUNTED EQUIPMENT WEIGHING LESS
THAN 400 LBS. AND HUNG EQUIPMENT WEIGHING LESS THAN 20 LBS MAY BE OMITTED FROM THE PLANS.
ALL MECHANICAL AND ELECTRICAL EQUIPMENT SHALL BE BRACED OR ANCHORED TO RESIST A HORIZONTAL FORCE
ACTING IN ANY DIRECTION USING THE FOLLOWING CRITERIA:
EQUIPMENT ON GRADE 23% OF OPERATING WEIGHT
EQUIPMENT ON STRUCTURE 35% OF OPERATING WEIGHT
FOR FLEXIBLY MOUNTED EQUIPMENT USE 2 X THE ABOVE VALUES, AND FOR SIMULTANEOUS VERTICAL FORCE USE
1/3 X THE HORIZONTAL FORCE.
THE ABOVE VALUES ARE FOR AN IMPORTANCE FACTOR, I=1.15 AND SEISMIC ZONE, Z=0.4.
WHERE ANCHORAGE DETAILS ARE NOT SHOWN ON THE DRAWINGS THE FIELD INSTALLATION SHALL BE SUBJECT TO
THE APPROVAL OF THE MECHANICAL ENGINEER.
ALL APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE SECURELY FASTENED IN PLACE PER BUILDING
CODE REQUIREMENTS.
SMOKE DETECTOR
OVERFLOW DRAIN
S SD
OD
EF
1
UNIT SHALL BE ELECTRICALLY INTERLOCKED WITH EF-1,2, 3
MA MAKE-UP AIR UNIT
"CHAMPION" EVAPORATIVE COOLER, MODEL 10/12SD
UNIT SHALL DELIVER 9,000 CFM @ 0.3 S.P.
2 H.P. MOTOR
ELECTRICAL: 208V-3Ø-60HZ
UNIT APPROX OPERATING WEIGHT = 731 LBS
1
KITCHEN HOOD EXHAUST FAN (GREASE)
"ECON AIR" MODEL DU180HFA UPBLAST CENTRIFUGAL ROOF
UNIT APPROX. WEIGHT = 181 LBS
3 HP FAN MOTOR
ELECTRICAL: 208V-3Ø-60HZ
UNIT SHALL DELIVER 3,600 CFM @ 1.25" SP
VENTILATOR OR EQUAL
AIR BALANCE SCHEDULE
ITEM SUPPLY AIR RETURN AIR MAKE-UP/OUTSIDE
AIR EXHAUST AIR PRESSURE
MA-1 0 0 +9,000 0 +9,000
EF-1 0 0 0 -3,600 -3,600
EF-2 0 0 0 -3,600 -3,600
EF-3 0 0 0 -1,800 -1,800
EF-4 0 0 0 -800 -800
EF-5 0 0 0 -600 -600
EF-6 0 0 0 -250 -250
HP-1 600 -350 0 0 +250
HP-2 4,000 -2,600 0 0 +1,400
TOTAL +4,600 -2,950 +9,000 -10,650 0
TENANT SPACE PRESSURE =0 CFM
C.B.
E
208V / 3PH / 60HZ
EE
C.B.
208V / 3PH / 60HZ
C.B.
DL
DL
DL
CC
DL
DL
DL
AUX
AUX
C
DL
DL
DL
208V / 3PH / 60HZ
HOOD OR ON WALL
PUSH BUTTON ON
E
E
SECTION OF PANEL
NON FUSED WP-DS
ON ROOF
E
ANSUL SYSTEM, NORMALLY
CLOSED DRY CONTACT
MAGNETIC STARTER IN CONTROL
12
(ON ROOF)
1
(ON ROOF)(ON ROOF)
NO SCALE
KITCHEN EXHAUST SYSTEM WIRING DIAGRAM
EFEF MA
EF
3
KITCHEN HOOD EXHAUST FAN (GREASE)
"ECON AIR" MODEL DU85HFA UPBLAST CENTRIFUGAL ROOF
UNIT APPROX. WEIGHT = 94 LBS
3/4 HP FAN MOTOR
ELECTRICAL: 110V-1Ø-60HZ
UNIT SHALL DELIVER 1,800 CFM @ 0.75" SP
VENTILATOR OR EQUAL
UNIT APPROX. WEIGHT = 348 LBS
EXISTING PACKAGED HEAT PUMP ROOFTOP UNIT
"TRANE" MODEL NO. 4WCC3018A
UNIT SHALL DELIVER 600 CFM @ 0.5" ESP.
18,000 BTUH ARI RATED COOLING CAPACITY, SEER=13.0
16,800 BTUH HEATING CAPACITY, HSPF=7.70 @ 47°F
ELECTRICAL: 208V-1Ø-60HZ
HP
OUTDOOR TEMPERATURE. MIN. OSA = 250 CFM
MIN. CIRCUIT AMPACITY = 10.6 AMPS
MAX. OVERCURRENT PROTECTION = 15 AMPS
1
(EXISTING)PROVIDE MERV13 FILTERS
UNIT APPROX. WEIGHT = 941 LBS
EXISTING PACKAGED HEAT PUMP ROOFTOP UNIT
"TRANE" MODEL NO. WSC120A3
UNIT SHALL DELIVER 4,000 CFM @ 0.5" ESP.
121,000 BTUH ARI RATED COOLING CAPACITY, SEER=10.7
108,000 BTUH HEATING CAPACITY, COP=2.2 @ 47°F
ELECTRICAL: 460V-3Ø-60HZ
HP
OUTDOOR TEMPERATURE. MIN. OSA = 1,400 CFM
MIN. CIRCUIT AMPACITY = 26.4 AMPS
MAX. OVERCURRENT PROTECTION = 35 AMPS
2
(EXISTING)PROVIDE ECONOMIZER, & MERV13 FILTERS
ROOM THERMOSTAT
NO SCALE
AC UNIT CONTROL WIRING DIAGRAM
E
E
A/C UNIT
CONTROL PANEL
CIRCUIT BREAKER
SHALL SHUT FAN
120 V - 1 Ø - 60 Hz
OPERATION
DETECTION SIGNAL
INTERLOCK TO SUPPLY
FAN CONTACT - UPON
ACTIVATION OF SMOKE
DISCONNECT SWITCH
DETECTOR
SMOKE DUCT
@ SUPPLY DUCTM
EM
M
E
M
TIME CLOCK
460 VOLT - 3 PHASE - 60 HERTZ
BY FIRE MARSHAL
TO FACP IF REQUIRED
EF
2
EF
4
KITCHEN HOOD EXHAUST FAN (NON-GREASE)
"ECON AIR" MODEL DU33HFA UPBLAST CENTRIFUGAL ROOF
UNIT APPROX. WEIGHT = 68 LBS
1/3 HP FAN MOTOR
ELECTRICAL: 110V-1Ø-60HZ
UNIT SHALL DELIVER 800 CFM @ 0.4" SP
VENTILATOR OR EQUAL
ROOF VENTILATOR
"COOK" MODEL ACE-100C2B OR EQUAL
ELECTRICAL: 120V-1Ø-60HZ, 1/6 HP MOTOR
EF
UNIT SHALL DELIVER 250 CFM @ 0.5" SP
UNIT SHALL BE ELECTRICALLY INTERLOCKED WITH LIGHT SWITCH
6
EF
5
KITCHEN HOOD EXHAUST FAN (NON-GREASE)
"ECON AIR" MODEL DU33HFA UPBLAST CENTRIFUGAL ROOF
UNIT APPROX. WEIGHT = 68 LBS
1/3 HP FAN MOTOR
ELECTRICAL: 110V-1Ø-60HZ
UNIT SHALL DELIVER 600 CFM @ 0.4" SP
VENTILATOR OR EQUAL
PROVIDE BACKDRAFT DAMPER
UNIT APPROX. WEIGHT = 68 LBS
BAND (TYP.)
2"x16 GA. (MIN.)
3/8"Ø BOLT
SWAY BRACING
TO STRUCT BEAM
HANGER ROD
1/2"Ø (MIN.)
6' MAX.
STEEL-GALVANIZED
SHEET GAUGE PER
CMC 2007 TABLE 6-8
RIGID DUCT SUPPORT DETAIL
N.T.S.
500
CFM
LE
D
L
E
D
LE
D
LE
D
L
E
D
LE
D
L
E
D
LE
D
LE
D
LE
D
LE
D
L
E
D
LE
D
L
E
D
LE
D
LE
D
LE
D
LE
D
L
E
D
LE
D
L
E
D
LE
D
LE
D
LE
D
LE
D
L
E
D
LED LED LED LED LED LED
LED
LED
LE
D
LE
D
LE
D
LE
D
LED
LED
LEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLED LEDLEDLEDLEDLED
LE
D
LE
D
LE
D
LE
D
LE
D
LE
D
LE
D
LE
D
LE
D
LE
D
LE
D
LE
D
LE
D
LE
D
HVAC FLOOR PLAN
500
CFM
500
CFM
500
CFM
500
CFM
500
CFM
500
CFM
10"x10" CD
300 CFM
8"x8" CD
200 CFM
12"Ø ROUND DIFFUSER
(TYP. FOR 7)
8"Ø 14"Ø
14"Ø
ALL EXPOSED DUCTWORK SHALL BE RIGID AND PAINTED
PER OWNER'S DIRECTION. INSTALL MIN. R-4.2 INTERNAL
LINING FOR EXPOSED SUPPLY AIR DUCT. FIELD VERIFY
MOUNTING HEIGHT OF DUCTWORK & REGISTERS WITH
OWNER/ARCHITECT.
14"Ø
14"Ø
14"Ø14"Ø
14"Ø26"Ø
10"Ø
10"x10" CD
300 CFM
14"x14" RR
400 CFM
10"x10" CD
300 CFM
10"Ø
10"Ø
12"Ø
10"Ø
8"x8" ER
100 CFM
8"x8" ER
150 CFM
S
S
HOOD #1 HOOD #2
HOOD #3
HOOD #4
HOOD #5
2250
CFM
2250
CFM
2250
CFM
2250
CFM
20"Ø
20"Ø
20"Ø
20"Ø26"Ø26"Ø
NOTES:
INSTALL NEW THERMOSTAT WITH LOCKABLE VENTED BOX
1
2
3
4
6
TO BE MOUNTED AT 48" A.F.F..
5
EXISTING SA/RA UP TO ROOF. FIELD VERIFY EXACT SIZE, &
LOCATION. PROVIDE DUCT MOUNTED SMOKE DETECTOR AT
MAIN SUPPLY DUCT IF THERE IS NONE.
7
6"Ø FLUE VENT UP TO ROOF.
GREASE EXHAUST DUCT, SEE PLAN FOR SIZE, UP TO ROOF,
WITH THERMAL CERAMIC FIREMASTER FASTDUCT XL OR EQUAL.
U. L. LISTED TYPE I GREASE HOOD, SEE M-4, & ECON-AIR PLANS
FOR DETAILS.
FABRICATE DUCT FROM 16 GAUGE STEEL WITH WELDED SEAM
CONSTRUCTION. SEE HOOD DETAIL DRAWING ON SHEET M-3.
1
1
12
32
22
3 3
3
4 18"Ø418"Ø
4 14"Ø
5 C
U
22"x22" SUPPLY DIFFUSER WITH PERFORATED FACE.
6 6
6
6
FULL SIZE MA DUCT UP TO ROOF MOUNTED MAU.
7
8 10"Ø EXHAUST DUCT UP TO ROOF.
9 10"Ø NON-GREASE EXHAUST DUCT FROM TYPE II HOOD UP TO
ROOF.
10 12"Ø NON-GREASE EXHAUST DUCT FROM TYPE II HOOD UP TO
ROOF.
9 10
8
36"x24" RR
2600 CFM
8"Ø6"Ø
26"Ø 24"Ø 24"Ø 16"Ø
20"Ø 14"Ø
Job No.
Sheet No.
Plot Date
Scale
Job Begin
JO
B
N
A
M
E
4/4/2023
1
2
REVISIONS:
SH
E
E
T
T
I
T
L
E
:
MONTEREY PARK, CA 91754
Tel: (626) 476-0518
EMAIL: TIANMUS@GMAIL.COM
Interior Design
3
4
TA
I
E
R
R
E
S
T
A
U
R
A
N
T
T
.
I
.
40
0
S
O
U
T
H
B
A
L
D
W
I
N
A
V
E
.
,
S
U
I
T
E
2
3
1
AR
C
A
D
I
A
,
C
A
9
1
0
0
7
646 Armitos Place Diamond Bar, CA 91765
T: 909.569.2586 Email: bkengineers88@gmail.com
B CONSULTING ENGINEERS INCK M-2
HV
A
C
F
L
O
O
R
P
L
A
N
HVAC ROOF PLAN
EF
6
HP
1
HP
2
NOTES:
1
2
3
4
EXISTING ECONOMIZER, SET MIN. OSA = 1,400 CFM.
EXISTING AC UNIT BY LANDLORD. FIELD VERIFY EXACT SIZE,
LOCATION, & CONDITION. PROVIDE SERVICES TO MAINTAIN
PROPER WORKING CONDITION. REPLACE TO MERV13 FILTERS
3/4" CONDENSATE DRAIN, & OVERFLOW DRAIN DN. TO MOP
SINK WITH 2" AIR GAP ABOVE FLOOD RIM.
EXISTING OSA INTAKE, ADJUST TO 200 CFM.
AFTER FINAL INSPECTION.
1
1
MIN. 10'-0" CLEARANCE (TYP.)
EF
1
EF
1
EF
3
EF
4
EF
5
MA
1
2
3
3/4"CD
3/4"CD
3/4"OD MIN. 1% SLOPE BELOW ROOF (TYP.)
4
5
Job No.
Sheet No.
Plot Date
Scale
Job Begin
JO
B
N
A
M
E
4/4/2023
1
2
REVISIONS:
SH
E
E
T
T
I
T
L
E
:
MONTEREY PARK, CA 91754
Tel: (626) 476-0518
EMAIL: TIANMUS@GMAIL.COM
Interior Design
3
4
TA
I
E
R
R
E
S
T
A
U
R
A
N
T
T
.
I
.
40
0
S
O
U
T
H
B
A
L
D
W
I
N
A
V
E
.
,
S
U
I
T
E
2
3
1
AR
C
A
D
I
A
,
C
A
9
1
0
0
7
646 Armitos Place Diamond Bar, CA 91765
T: 909.569.2586 Email: bkengineers88@gmail.com
B CONSULTING ENGINEERS INCK M-3
HV
A
C
R
O
O
F
P
L
A
N
HOOD SUPPORT TO ROOF
SEE DETAIL 1/-
#10 SCREW TO EACH END
#10 SCREW TO EACH END
5/8" GREEN BD.
HOOD SUPPORT TO ROOF
SEE DETAIL 1/-
1/2"® HOOD
HANGER WITH MAX.
200 LBS LOAD
6X6#1
ADD 2X6 FLAT WITH 4-16dc TOP & BOTT CHARD
ROOF TRUSS DESIGNED TO
INCLUDE HOOD WEIGHT
H3
HOOD CONNECTION AT KITCHEN
NO SCALE
2
HOOD SUPPORT CONNECTION
NO SCALE
1
3
KITCHEN HOOD
T-BAR DROP CEILING
10'-0" A.F.F.
6"
M
I
N
.
NO SCALE
HOOD TO CEILING
18
"
M
I
N
.
24
"
6'-6" A.F.F.
STAINLESS STEEL PANEL AROVE THE HOOD
MIN. 3"
EXTENDED CEILNG
Job No.
Sheet No.
Plot Date
Scale
Job Begin
JO
B
N
A
M
E
4/4/2023
1
2
REVISIONS:
SH
E
E
T
T
I
T
L
E
:
MONTEREY PARK, CA 91754
Tel: (626) 476-0518
EMAIL: TIANMUS@GMAIL.COM
Interior Design
3
4
TA
I
E
R
R
E
S
T
A
U
R
A
N
T
T
.
I
.
40
0
S
O
U
T
H
B
A
L
D
W
I
N
A
V
E
.
,
S
U
I
T
E
2
3
1
AR
C
A
D
I
A
,
C
A
9
1
0
0
7
646 Armitos Place Diamond Bar, CA 91765
T: 909.569.2586 Email: bkengineers88@gmail.com
B CONSULTING ENGINEERS INCK M-4
CO
D
E
C
O
M
P
L
I
A
N
C
E
D
W
G
S
,
&
H
O
O
D
D
E
T
A
I
L
S
WITH SCREWS, NAILS, ETC..
AND SEAMS ON THE EXTERNAL
DO NOT PENETRATE DUCT WALLS
REQUIRED BY TABLE 6 E.
5. WELD OR BRAZE ALL DUCT JOINTS
CONTAIN GREASE POCKETS.
7. SECTIONS OF DUCT SHALL NOT
U.S. GAGE STEEL
4. THICKNESS OF DUCTS SHALL BE:
6. SUPPORT THE DUCTS AS
GENERAL NOTES (N.T.S.)
SURFACE.
UP TO 4 SQ. FT.
OVER 4 SQ. FT.
DUCT AREA
14 GA.
16 GA.
GENERAL - FOR ALL GREASE DUCTS
PROPER OPERATION.
3. PROVIDE A SEPARATE DUCT SYSTEM
FOR EACH HOOD (SEE EXCEPTION).
2. PROVIDE ADEQUATE MAKE-UP AIR FOR
1. PROVIDE ADEQUATE CLEANOUT OPENINGS
FOR THOROUGH CLEANING OF DUCT
SYSTEM.
PLACE BY INCOMBUSTIBLE SUPPORTS.
HOODS SHALL BE SECURELY FASTENED IN
GENERAL - FOR ALL HOODS
DRAIN TO A COLLECTING PAN WHICH IS
AND THE COOKING OR HEATING SURFACE.
BETWEEN LOWER EDGE OF GREASE FILTER
READILY ACCESSIBLE FOR CLEANING
SEE TABLE 507.11 FOR MINIMUM DISTANCE
WHEN GUTTERS ARE PROVIDED THEY SHALL
STAINLESS STEEL TO BE MIN. 20 MSG
GALVANIZED STEEL TO BE MIN. 18 MSG OR
ALL JOINTS AND SEAMS SHALL BE GREASE
CONSTRUCTION AND READILY ACCESSIBLE
GREASE FILTERS SHALL BE OF STEEL
FOR CLEANING.
TIGHT.
HORIZONTAL SUPPORT DETAIL (N.T.S.)VERTICAL SUPPORT DETAIL
(N.T.S.)GREASE DUCT WRAP DETAIL (N.T.S.)ACCESS DOOR DETAIL
EXHAUST FAN
1. TYPE : CANOPY TYPE I, STAINLESS STEEL 20 GAUGE,
HOOD #1, #2: (2) CHINESE WOK, PASTA COOKER, NOODLE COOKER
2,037 FPM < 2,500FPM
7. EXHAUST VELOCITY @ EXHAUST DUCT
8. EXHAUST FAN AND MAKE-UP AIR UNIT
EF-1, EF-2 (3,600 CFM EACH), EF-3 (1,800 CFM); MA-1 (9,000 CFM)
5. PROPOSED (3) EXHAUST FAN & (1) MAKE-UP AIR UNIT
SHALL BE ELECTRICALLY INTERLOCKED
HOOD #1, #2: U.L. LISTED HOOD WITH 3,600 CFM EACH
3,600/(8"x8"x3.14/144)= 2,037 FPM
4. MIN. REQ'D CAPACITY CFM
9. FOR CODE COMPLIANCE SEE DETAIL
6. EXHAUST DUCT SIZE:
2. COOKING EQUIPMENT
AS FOLLOW:
EF-1, EF-2, EF-3
MAKE-UP AIR
MA-1
HOOD #1, #2: 12'-0" x 4'-6" EACH3. SIZE:
NO. OF FILTERS: SEE ECON AIR PLANS
10. FILTER SIZE: 20"x16"x2"
HOOD #1, #2:
HOOD #1, #2: 18"Ø
(N.T.S.)(N.T.S.)
PLAN CHECK NOTES:
1.FIELD APPLIED OR FACTORY BUILT GREASE DUCT ENCLOSURE SHALL BE INSTALLED PER THE
LATEST MANUFACTURER'S INSTALLATION INSTRUCTIONS AND IN COMPLIANCE WITH TERMS OF ITS
LISTING.
2.ALL END CUTS OR CUTS IN THE FOIL JACKET OF FIELD APPLIED GREASE DUCT ENCLOSURE SHALL BE
SEALED PER THE MANUFACTURER'S RECOMMENDATIONS.
3.ALL INSTALLATIONS SHALL BE COMPLETELY ACCESSIBLE FOR VISUAL INSPECTION.
4.AT TIME OF INSPECTION, THE FIELD APPLIED OR FACTORY BUILT GREASE DUCT ENCLOSURE
INSTALLATION INSTRUCTIONS SHALL BE MADE AVAILABLE AT THE JOT SITE.
5.LISTED GREASE HOOD ASSEMBLIES SHALL BE INSTALLED IN ACCORDANCE WITH THE TERMS OF
THEIR LISTING AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
6.FIRE DEPARTMENT APPROVAL SHALL BE REQUIRED ON FIRE PROTECTION SYSTEM FOR GREASE
HOODS AND DUCTS AS REQUIRED BY SECTION 513 OF THE CALIFORNIA MECHANICAL CODE AND AS
REQUIRED BY THE FIRE CODE.
7.ALL FIRE-EXTINGUISHING SYSTEMS SHALL BE INTERCONNECTED TO THE FUEL OR CURRENT SUPPLY
SO THAT THE FUEL OR CURRENT IS AUTOMATICALLY SHUT OFF TO ALL EQUIPMENT UNDER THE
HOOD WHEN THE SYSTEM IS ACTIVATED.
8.OWNER OF ESTABLISHMENT SHALL BE RESPONSIBLE FOR CLEANLINESS, MAINTENANCE, AND
INSPECTION OF KITCHEN EXHAUST SYSTEM, FIRE PROTECTION, AND COOKING EQUIPMENT.
9.A DRAWING OF THE EXHAUST SYSTEM(S) INSTALLATION ALONG WITH A COPY OF OPERATING
INSTRUCTIONS FOR SUBASSEMBLIES AND COMPONENTS USED IN THE EXHAUST SYSTEM(S),
INCLUDING ELECTRICAL SCHEMATICS, SHALL BE AVAILABLE ON THE PREMISES.
10.ALL SEAMS, JOINTS, AND PENETRATIONS OF THE HOOD ENCLOSURE THAT DIRECT AND CAPTURE
GREASE-LADEN VAPORS AND EXHAUST GASES SHALL HAVE A LIQUID TIGHT CONTINUOUS EXTERNAL
WELD TO THE LOWER OUTERMOST PERIMETER OF THE HOOD.
11.HOOD EXHAUST FAN SHALL CONTINUE TO OPERATE AFTER THE EXTINGUISHING SYSTEM HAS BEEN
ACTIVATED, UNLESS FAN SHUTDOWN IS REQUIRED BY A LISTED COMPONENT OF THE VENTILATION
SYSTEM.
12.DUCTS (OTHER THAN LISTED GREASE DUCT) SHALL BE CONSTRUCTED OF AND SUPPORTED BY
CARBON STEEL NOT LESS THAN 0.060" (NO. 16 MSG) IN THICKNESS OR STAINLESS STEEL NOT LESS
THAN 0.048" (NO. 18 MSG) IN THICKNESS.
HOOD #3: 8'-0" x 4'-6"
HOOD #3: U.L. LISTED HOOD WITH 1,800 CFM
1,800/(7"x7"x3.14/144)= 1,684 FPM
1,684 FPM < 2,500FPM
HOOD #3:
HOOD #2: 14"Ø
REMOVABLE GREASE FILTER W/ HANDLES
AUTO FIRE EXTINGUISHER (SEPARATE
6" TYP. @ ALL OPEN SIDES
PERMIT BY FIRE EXTINGUISHER CO.)
MTL. WALL FLASHING 24 GA. S/S SHEET MTL.
FIN. FLOOR
3" MIN.
METAL STUD WALL
W/ 5/8" TYPE "X"
GYP. BD. ON
BOTH SIDE
EQUIPMENT
COOKING
3" MIN.
48"
-
1
16 GA. GI. DUCT
MTL. HOOD 22 GA. S/S
ROOF DECK
EXTENDED FIRE RATED
18" BELOW CEILING,
WHEN HOOD IS LESS THAN
HOOD ON BOTH SIDE
CEILING 18" BEYOND THE
CEILING
MTL. WALL FLASHING 24 GA.
COOKING EQUIPMENT
6" MIN.
6"
7'-0"
S/S SHEET MTL.
FIN. FLOOR
6" MIN,
W/ REMOVABLE GREASE FILTER
TYP. HOOD LIGHT W/ SHIELD INSIDE HOOD,
AUTO FIRE EXTINGUISHER (SEPARATE
PERMIT BY FIRE EXTINGUISHER CO.)
UL APPROVED (IF INSTALLED)
12" FROM CEILING MUST
BE FLASHED SOLID
HOOD LESS THAN
48"
GREASE CONTAINER
20 GA. S/S MTL. HOOD
ROOF DECK
18"
10' FROM ADJACENT BUILDINGKEEP MIN. 10' AWAY FROM ADJACENT BLDG OR
BLDG OSA INTAKE OPENING AROUND FAN
CODE APPROVED GREASE PORT
AIR IN TAKE OPENING
10' ABOVE GRADE LEVEL
10' FROM PROPERTY LINE &
48" MIN.
BLOWER
16 GA. GI. DUCT 24" MIN.
2-LAYER DUCT WRAP
MIN. 18"
2-LAYER DUCT WRAP
WITH COLLECTION TROUGH OR CARTRIDGE
HOOD #1, #2: STOCK POT RANGE, RICE COOKER, (2) DEEP FRYER
W/
YB
VTR
TYP.
VENT THROUGH ROOF
YARD BOX
WITH
TYPICAL
TEMP.
PLBG
GPM
CONT.
FLR.
DN.
PLUMBING
TEMPERATURE
GALLONS PER MINUTE
CONTINUATION
FLOOR
DOWN
PLUMBING EQUIPMENT DESIGNATION
PLUMBING FIXTURE DESIGNATION
SANITARY SEWER OR WASTE BELOW GRADE/FLOOR
SANITARY SEWER OR WASTE ABOVE GRADE/FLOOR
AP
ABV
WC - 1
E
WH
EXIST`G
FS
FD
ACCESS PANEL
ABOVE
EXISTING
FLOOR SINK
FLOOR DRAIN
GV
U
POC
GLV
STR
G
WHA
WCO
COTG
G
FCO
GATE VALVE
GLOBE VALVE
POINT OF CONNECTION
GAS OR GATE COCK
UNION
STRAINER
WATER HAMMER ARRESTOR
WALL CLEANOUT
FLOOR CLEANOUT
CLEANOUT TO GRADE
NATURAL GAS
PLUMBING LEGEND
S OR W
D
V
CW
HW
D
V
SYMBOL ABBREV.
S OR W
INDIRECT DRAIN
SANITARY VENT
DOMESTIC COLD WATER
DOMESTIC HOT WATER
DEFINITION
NON-RESIDENTIAL ENERGY CONSERVATION STANDARDS NOTE :
STANDARDS.
STANDARD.
STANDARD.
1. PIPING INSULATION SHALL COMPLY WITH CEC BUILDING ENERGY EFFICIENCY
2. ALL PLUMBING EQUIPMENT SHALL BE CERTIFIED PER CEC BUILDING EFFICIENCY
3. THE "MANDATORY MEASURES" OF THE ENERGY EFFICIENCY STANDARD HAVE BEEN
REVIEWED AND THE DESIGN, DRAWINGS AND CALCULATIONS COMPLY WITH THESE
RPPBFP REDUCE PRESSURE PRINCIPLE BACKFLOW PREVENTER
OVERHEAD C.W. SUPPLY
TRAP PRIMER
TYPICAL TRAP PRIMER DETAIL
NO SCALE
GRAVITY LINE TO TRAP
C.W. SUPPLY
FINISH FLOOR
VACUUM BREAKER
UNION
NOTE: PROVIDE TRAP PRIMER CONNECTION
W/ AIR GAP REQUIRED PER 2022 UPC SEC.603,3
MIN. 1" AIR GAP
PROVIDED & INSTALLED BY PLUMBING CONTRACTOR. ALL EQUIPMENT SHALL BE APPROVED
PROVIDED BY OWNER/EQUIPMENT COMPANY, INSTALLED BY PLUMBING CONTRACTOR.
1
2
FS
1
1
S
2
FLOOR SINK 3"HALF GRATE,
"ZURN" OR EQUAL2"2"1
PIPE CONNECTION
PLUMBING FIXTURE SCHEDULE
TRAPSYMBOL
S
FIXTURE TYPE WASTE DESCRIPTIONVENTCWHW
2""JR. SMITH" 2005 TRAPPED WITH
TRAP PRIMER 1FLOOR DRAINFD
1 1-1/2"1-1/2"
(WALL MOUNTED)2"1-1/2"1-1/2"1/2"1/2"HAND SINK SEE KITCHEN DWGS FOR EQUIPMENT &
FAUCET MODEL 2
ALL PLUMBING FIXTURES SHALL BE LISTED AND LABELED.3
3
BY THE ARCHITECT AND OWNER.
(1 COMP. SINK)
PREP. SINK SEE KITCHEN DWGS FOR EQUIPMENT &
FAUCET MODEL 23/4"3/4"FS
11
GWH GAS WATER HEATER 120,000 GAS INPUT, EF: 0.8
"A O SMITH" BTL-120, 80 GAL. TANK CAPACITY
Job No.
Sheet No.
Plot Date
Scale
Job Begin
JO
B
N
A
M
E
4/4/2023
1
2
REVISIONS:
SH
E
E
T
T
I
T
L
E
:
MONTEREY PARK, CA 91754
Tel: (626) 476-0518
EMAIL: TIANMUS@GMAIL.COM
Interior Design
3
4
TA
I
E
R
R
E
S
T
A
U
R
A
N
T
T
.
I
.
40
0
S
O
U
T
H
B
A
L
D
W
I
N
A
V
E
.
,
S
U
I
T
E
2
3
1
AR
C
A
D
I
A
,
C
A
9
1
0
0
7
646 Armitos Place Diamond Bar, CA 91765
T: 909.569.2586 Email: bkengineers88@gmail.com
B CONSULTING ENGINEERS INCK
192 GPH REC. @ 60°F RISE
L
1 (DISABLED)2"1-1/2"1-1/2"LAVATORY A/S WALL MOUNTED, WHITE VITREOUS CHINA,
WC
1 (DISABLED)4"2"INTWATER CLOSET A/S FLOOR MOUNTED, FLUSH VALVE, MAX 1.28
GPF, ELONGATED, ADA COMPLIANT, OPEN FRONT
SEAT W/ LESS COVER, WHITE VITREOUS CHINA
SELF-CLOSING FAUCETS, MAX. 0.25 GPM, WITH
MIXING VALVE SET @ 110°F MAX. ADA COMPLIANT
1/2"1/2"
UR
1 (DISABLED)2"1-1/2"1-1/2"URINAL FLUSH VAVLE, MAX. 0.125 GPF, ADA COMPLIANT,
WHITE VITREOUS CHINA,
1-1/2"
1-1/4"
3
S
3"2"2"MOP SINK PROVIDE NON-REMOVABLE VACUUM BREAKER3/4"3/4"SELECTED BY OWNER
1
1
1
2
(E) 2
41
NEW F.U.
56
TOTAL F.U.
GPM
CFH
F.U.
INCH
INCH
INCH(E) (2) 4
SIZE MAIN CAPACITY
SERVICE
DOMESTIC WATER
SANITARY SEWER
SERVICE
FUEL GAS
DOMESTIC WATER
SANITARY SEWER
FIXTURE UNIT SUMMARY
SERVICE REQUIREMENTS
OLD F.U.
0
0
47
56
720
41
56
2-1/2
* SEE FIXTURE UNIT TABLE FOR DETAIL
4
S
5
S
1
DW
(3 COMP. SINK)
POT SINK SEE KITCHEN DWGS FOR EQUIPMENT &
FAUCET MODEL 23/4"3/4"
WASH SINK SEE KITCHEN DWGS FOR EQUIPMENT &
FAUCET MODEL 2
3/4"DISHWASHER SEE KITCHEN DWGS FOR EQUIPMENT &
FAUCET MODEL 2FS
FS
2 FLOOR SINK HALF GRATE,
"ZURN" OR EQUAL 12"1-1/2"1-1/2"
SERVICE
COLD & HOT WATER
SANITARY VENT
SANITARY WASTE
"NO-HUB" CAST IRON OR ABS *
"NO-HUB" CAST IRON OR ABS *
GALV. STEEL, SCHEDULE 40/
"NO-HUB" CAST IRON
ABOVE GROUND
HARD DRAWN COPPER TUBEHARD DRAWN COPPER TUBE
UNDERGROUND
PIPE MATERIAL SCHEDULE
TYPE "K" OR "L"TYPE "L" **
"NO-HUB" CAST IRON
NOTE: * ABS MAY BE USED ONLY WITH OWNER AND LOCAL AUTHORITY APPROVAL.
OR ABS *
OR ABS *
GAS BLACK STEEL, SCHEDULE 40
INDIRECT DRAIN
HARD DRAWN COPPER TUBE
TYPE "M"
** CPVC, & PEX MAY BE USED ONLY WITH OWNER AND LOCAL AUTHORITY APPROVAL.
N.T.S.
SEDIMENT TRAP
MIN.3" (80mm)
GAS SUPPLY INLET
TEE FITTING
TO
EQUIPMENT
INLET
NIPPLE
CAP
1
WHA WATER HAMMER ARRESTOR 1""C", FIXTURE UNIT RATING : 61-113
"JR. SMITH" MODEL: 5020, P.D.I. SYMBOLS
MIN. 1,250 GAL. CAPACITY REQUIRED PER 2022 CPC. EXISTING 1,500 GAL. GREASE INTERCEPTOR PROVIDED BY LANDLORD.
GREASE INTERCEPTOR CALCULATION
FIXTURE QUANTITY SEWER FU EACH SEWER FU TOTAL
FLOOR SINK 6 3 18
FLOOR SINK 1 1 1
HAND SINK 1 1 1
3-COMP SINK 1 3 3
MOP SINK 1 3 3
FLOOR DRAIN 3 2 6
TRENCH DRAIN 1 3 3
TOTAL 35
1
3"2"2"
1-1/4"1-1/4"
1
CP CIRCULATING PUMP 5 GPM @ 10FT HD., 1/12 HP MOTOR.
IN-LINE HOT WATER CIRCULATING PUMP,3/4"1
P-1
PL
U
M
B
I
N
G
L
E
G
E
N
D
,
NO
T
E
,
&
S
C
H
E
D
U
L
E
1
GW 3/4"GLASS WASHER SEE KITCHEN DWGS FOR EQUIPMENT &
FAUCET MODEL 2FS
PLUMBING GENERAL NOTES
1.THE PLUMBING SYSTEM SHALL COMPLY WITH THE 2022 CALIFORNIA PLUMBING CODE.
2.DRAWING AND SPECIFICATIONS GOVERN WHERE THEY EXCEED CODE REQUIREMENTS.
3.CONTRACTOR SHALL VERIFY LOCATION AND DEPTH OF UTILITIES AT POINT OF CONNECTION
BEFORE START OF WORK.
4.REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF PLUMBING FIXTURES.
5.ALL UNDERGROUND SHUT OFF VALVES OUTSIDE OF BUILDING SHALL BE IN CONCRETE BOXES WITH
THE NAME OF THE SERVICE CASTED IN THE COVER.
6.ALL PLUMBING FIXTURES AND EQUIPMENT SHALL HAVE ISOLATING VALVES ON WATER SUPPLY
LINES. VALVE SHALL BE LINE SIZE, UNLESS NOTED OTHERWISE.
7.ALL PLUGGED TEES AND PLUGGED WYES SHALL BE LINE SIZE, UNLESS NOTED OTHERWISE.
8.ALL PIPING PENETRATING WALL, CEILING, AND FLOOR SHALL BE ISOLATED FROM BUILDING
STRUCTURES WITH RESILIENT SEALS.
9.RUN ALL INDOOR PLUMBING PIPING CONCEALED IN WALL OR ABOVE CEILING, UNLESS NOTED
OTHERWISE.
10.PROVIDE DIELECTRIC UNIONS AT BIMETALLIC PIPE JOINTS.
11.PROVIDE CHROME PLATED CAPS FOR WALL CLEANOUTS.
12.WASTE LINE SHALL BE SLOPED NOT LESS THAN 1/4" PER FT. IN THE DIRECTION OF FLOW.
13.ALL VALVES AND COCKS SHALL BE LOCATED TO BE READILY ACCESSIBLE. WHERE VALVES ARE
INSTALLED WITHIN OR BEHIND WALLS OR CEILING, ACCESS PANEL SHALL BE INSTALLED.
14. WATER SUPPLY AND DRAIN PIPES UNDER ACCESSIBLE LAVATORIES AND SINKS SHALL BE
INSULATED OR OTHERWISE BE CONFIGURED TO PROTECT AGAINST CONTACT. PROTECTORS,
INSULATORS, OR BOTH SHALL COMPLY WITH ASME A112.18.9.
15.EACH VENT SHALL TERMINATE NOT LESS THAN 10 FT. FROM, OR AT LEAST 3 FT. ABOVE ANY
WINDOW, DOOR, OPENING AIR INTAKE OR VENT SHAFT, NOR LESS THAN 3 FT. IN EVERY DIRECTION
FROM ANY LOT LINE; ALLEY AND STREET EXCEPTED.
16.ALL REQUIRED CLEANOUTS SHALL BE INSTALLED AS PER SEC. 707.0 & 719.0 OF THE PLUMBING
CODE.
17.EACH VENT SHALL RISE VERTICALLY TO A POINT NOT LESS THAN SIX (6) INCHES IN HEIGHT ABOVE
THE FLOOD LEVEL RIM OF THE FIXTURE BEFORE BEING CONNECTED TO ANY OTHER VENT.
18.NEW OR REPAIRED POTABLE WATER SYSTEMS SHALL BE DISINFECTED PRIOR TO USE ACCORDING
TO THE METHOD SET IN SECTION 609.9 OF THE PLUMBING CODE.
19.PLUMBING FIXTURES SHALL BE CERTIFIED BY CEC. (WATER CLOSET 1.28 GPF, URINAL 0.125 GPF,
SHOWER HEAD 2.0 GPM, COMMERCIAL SINK FAUCETS 1.8 GPM, LAVATORY(METERING) 0.2GPM.)
20.PROVIDE NON-LEAD SOLDER FOR POTABLE WATER PIPING JOINTS AND CONNECTION.
21.MAX. HOT WATER TEMPERATURE TO PUBLIC LAVATORIES TO BE 110°F & MIN. HOT WATER
TEMPERATURE TO KITCHEN FIXTURES TO BE 120°F.
22.FLOOR DRAIN OR SIMILAR TRAPS DIRECTLY CONNECTED TO THE DRAINAGE SYSTEM AND SUBJECT
TO INFREQUENT USE SHALL BE PROVIDED WITH TRAP PRIMING. TRAP PRIMING DEVICES SHALL BE
ACCESSIBLE FOR MAINTENANCE.(SECTION 1007 CPC)
23.COMBUSTIBLE PIPING INSTALLATIONS SHALL BE INSTALLED PER CHAPTER 14 OF THE CALIFORNIA
PLUMBING CODE FOR "FIRESTOP PROTECTION."
24.PROPOSED ADDITION, ALTERATION, OR IMPROVEMENT REQUIRES ALL NON-COMPLIANT FIXTURES
TO BE REPLACED WITH WATER CONSERVING PLUMBING FIXTURE.
25.CONDENSATE DRAIN ARE TRAPPED IN ACCORDANCE WITH THE APPLIANCE MANUFACTURER'S
INSTRUCTION.
26.PROTECT RECEPTOR ON ROOF OR OUTSIDE OF BUILDING FROM RAIN WATER BY ELEVATING THE
RIM TWO (2) INCHES ABOVE ADJACENT SURFACE.
27.PUBLIC LAVATORIES SHALL HAVE A WATER TEMPERING DEVICE THAT COMPLIES WITH ASSE 1070
OR CSA B125.3. WATER HEATER THERMOSTAT SHALL NOT BE CONSIDERED A CONTROL TO MEET
THIS PROVISION.
28.INSULATION OF DOMESTIC HOT WATER PIPING SHALL BE IN ACCORDANCE WITH SECTION 609.11.1
AND SECTION 609.11.2.
29.INDIRECT WASTE PIPING FROM FOOD HANDLING FIXTURES OR EQUIPMENT SHALL BE SEPARATELY
PIPED BY MEANS OF AN AIR GAP TO THE INDIRECT WASTE RECEPTOR & SHALL NOT BE COMBINED
WITH ANY OTHER INDIRECT WASTE PIPING. CPC 801.3.
30.POTABLE WATER SUPPLY TO BEVERAGE DISPENSERS, CARBONATORS OR COFFEE MACHINES
SHALL BE PROTECTED BY AN AIR GAP OR A VENTED BACKFLOW PREVENTER IN ACCORDANCE WITH
ASSE 1022. CPC 603.5.12.
31.ICE MACHINES, DRINK DISPENSERS, COFFEE MACHINES, FREEZER, REFRIGERATION COILS, &
SIMILAR EQUIPMENT SHALL BE INDIRECTLY CONNECTED TO THE DRAINAGE SYSTEM. CPC 801.3
32.ALL EXPOSED GAS PIPING SHALL BE PROTECTED AGAINST CORROSION BY COATING OR WRAPPING
WITH AN INERT MATERIAL APPROVED FOR SUCH APPLICATIONS. CPC 1210.2
DRAIN VALVE
NO SCALE
GAS WATER HEATER DETAIL
"AMTROL" THREM-X-TROL THERMAL
EXPANSION TANK OR APPROVED EQUAL. 5 GAL.
CHECK VALVE
GATE VALVE
C.W. SUPPLY
H.W. TO SYSTEM
PRESS & TEMP RELIEF SPILL TO
MS-1
TIMECLOCK
120V
C.B.
AQUASTAT
CP-1
GAS SUPPLY
GAS COCK
UNION
%%uGWH-1
CP-1
AQUASTAT
3/4"
W.H.R.
THERMOMETER
STPAPING
FLUE THRU ROOF TO
APPROVED VENI CAP
(COLD WATER)
F.U. @ psi
F.U. @ psi
F.U. @ psi
F - TANK
(E) COLD WATER PIPE SIZING CHART
28
12
MAX. 8
19.0
9.0
3.0 3
FT/SECGPMVELOCITYPIPE
SIZE
1/2"
1"
3/4"
10.0
FIXTURE UNITS
F - VALVE
F.U. @ psi
F.U. @ psi
F.U. @ psi
F.U. @ psi5631.01-1/4"F.U. @ psi
(HOT WATER)
F.U. @ psi
F.U. @ psi
F.U. @ psi
F - TANK
(E) HOT WATER PIPE SIZING CHART
28
8
MAX. 5
19.0
7.0
3.0 3
FT/SECGPMVELOCITYPIPE
SIZE
1/2"
3/4"
10.0
FIXTURE UNITS
F - VALVE
F.U. @ psi
F.U. @ psi
F.U. @ psi
F.U. @ psi44.01-1/2"F.U. @ psi10335
F.U. @ psi1612.01"F.U. @ psi
1-1/4"
14
F.U. @ psi76.0 F.U. @ psi2541322"
1/4" HOLES ON
FOR VENTILATION
3/4" CENTERS
ROOF RAFTERS
WALL FLUE
TYPE "B" DOUBLE
PLYWOOD
ROOF
MATERIAL
1" CLEARANCE BETWEEN
FLUE AND COMBUSTIBLE
FLUE VENT DETAIL
NO SCALE
VENT CAP
SHIELD
FLASHING
WEATHER
24"
DOUBLE JOISTS AROUND OPENING
3/4"3/4"FS
TD
1 TRENCH DRAIN 3"
"ZURN" MODEL Z886 OR EQUAL, 8'-0" EACH, SEE
PLAN FOR EXACT LENGTH, & OUTLET LOCATION, 2"2"6" WIDE FULL GRATE
打单机打单机
打单机
打单
机
W/T
干手机 纸巾盒
mopLocker
LE
D
L
E
D
LE
D
变压
器
4" CO
4" CO
3" CO
3" CO
3" CO
1
FD
1
WC
1
UR
1
L
1
L
1
WC
1
S
1
FS
5
2
S
3
S
4
S
3
S
5
S
1
FS
5
1
FD
1
FD
1
TD
1
FS
1
FS
1
FS
1
FS
1
FS
2
FS
FIXTURE WASTE FU
FIXTURE TYPE QTY EACH TOTAL
WATER CLOSET 2 4 8
URINAL 1 2 2
LAVATORY 2 1 2
1-COMP SINK 1 FS #
3-COMP SINK 1 3 3
HAND SINK 2 1 2
MOP SINK 1 3 3
WASH SINK 3 FS #
DISHWASHER 1 FS #
GLASS WASHER 1 FS #
FLOOR SINK 8 3 24
FLOOR SINK 1 1 1
FLOOR DRAIN 4 2 8
TRENCH DRAIN 1 3 3
TOTAL 56
WC
1
UR
1
L
1
S
1
S
2
S
3
S
4
S
5
DW
1
GW
1
FS
1
FS
2
FD
1
TD
1
NOTE:
OF NEW WORK TO BE COMPLETED BEFORE SUBMITTING BIDS.
CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, & EXTENT
DRAWINGS ARE ONLY AN APPROXIMATION OF EXISTING CONDITIONS,
NOTES:
3/4" FROM T&P VALVE DRAIN TO MOP SINK WITH 2" AIR GAP ABOVE
FLOOD RIM.
1
2
3
4
5
6
EXISTING 4" SANITARY SEWER / GREASE SEWER BY LANDLORD.
PROVIDE MIN. 2" INDIRECT DRAIN FROM SINK / DISHWASHER TO
FLOOR SINK WITH 2" AIR GAP.
PROVIDE MIN. 1" INDIRECT DRAIN FROM APPLIANCE TO FLOOR
SINK WITH 2" AIR GAP. SEE EQUIPMENT PLANS FOR DETAIL.
3"V CONNECT TO EXISTING 3"V BY LANDLORD. FIELD VERIFY EXACT
SIZE, & LOCATION.
4" SANITARY SEWER / GREASE SEWER CONNECT TO EXISTING 4"
SANITARY SEWER / GREASE SEWER BY LANDLORD. FIELD VERIFY
FIELD VERIFY EXACT SIZE, LOCATION, & DEPTH.
WASTE & VENT FLOOR PLAN
P.O.C.3
P.O.C.3
P.O.C.4
MIN. 2% SLOPE (TYP.)
1
DW
5
1
GW
5
1
FD
(E) 4"GS
(E) 4"S
4"GS
4"S 4"S
4"S
4"S
3"S
3"S
3"S
3"S
3"GS 3"GS
2"GS3"GS3"GS3"GS
3"GS
2"GS4"GS
4"GS
4"GS
3"GS
3"GS
3"GS
3"GS
2"GS
2"S 3"GS 4"S
2"S
2"S
2"V2"V
2"V2"V
3"GS
2-1/2"V
2-1/2"V
2"V
2"V3"V 2-1/2"V
2"V 2"V
2"V
2"V
3"V
1
1
GWH
EXACT SIZE, LOCATION, DEPTH, & DIRECTION.
2
2
6
6
7 EXISTING 4" GREASE SEWER CONTINUE & CONNECT TO EXISTING
GREASE INTERCEPTOR BY LANDLORD. FIELD VERIFY EXACT SIZE,
& LOCATION, MIN. 1,250 GAL. REQUIRED.
7
Job No.
Sheet No.
Plot Date
Scale
Job Begin
JO
B
N
A
M
E
4/4/2023
1
2
REVISIONS:
SH
E
E
T
T
I
T
L
E
:
MONTEREY PARK, CA 91754
Tel: (626) 476-0518
EMAIL: TIANMUS@GMAIL.COM
Interior Design
3
4
TA
I
E
R
R
E
S
T
A
U
R
A
N
T
T
.
I
.
40
0
S
O
U
T
H
B
A
L
D
W
I
N
A
V
E
.
,
S
U
I
T
E
2
3
1
AR
C
A
D
I
A
,
C
A
9
1
0
0
7
646 Armitos Place Diamond Bar, CA 91765
T: 909.569.2586 Email: bkengineers88@gmail.com
B CONSULTING ENGINEERS INCK P-2
WA
S
T
E
&
V
E
N
T
F
L
O
O
R
P
L
A
N
打单机打单机
打单机
打单
机
W/T
干手机 纸巾盒
mopLocker
LE
D
L
E
D
LE
D
变压
器
1
WC
1
UR
1
L
1
L
1
WC
1
S
2
S
3
S
4
S
3
S
5
S
1
DW
1
GW
1
GWH
1
CP
FIXTURE WATER FU
FIXTURE TYPE QTY EACH TOTAL
WATER CLOSET 2 5 10
URNIAL 1 2 2
LAVATORY 2 1 2
1-COMP SINK 1 3 3
3-COMP SINK 1 3 3
HAND SINK 2 1 2
MOP SINK 1 3 3
WASH SIHNK 3 2 6
DISHWASHER 1 2 2
GLASS WASHER 1 2 2
ICE MAKER 1 1 1
WOK FAUCET 4 1 4
MAKE-UP AIR UNIT 1 1 1
TOTAL 41
WC
1
UR
1
L
1
S
1
S
2
S
3
S
4
S
5
DW
1
GW
1
CFH
ITEM Q'TY EQUIPMENT 1,000
BTUH/EACH EACH TOTAL
1 WATER HEATER 120 120 120
1 SOUP POT RANGE 100 100 100
1 RICE COOKER 35 35 35
2 DEEP FRYER 120 120 240
1 WOK RANGE 150 150 150
1 WOK RANGE 75 75 75
TOTAL 720
1
2
3
4
5
6NOTE:
OF NEW WORK TO BE COMPLETED BEFORE SUBMITTING BIDS.
CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, & EXTENT
DRAWINGS ARE ONLY AN APPROXIMATION OF EXISTING CONDITIONS,
HOT WATER CALCULATION:
(1) 3-COMP SINK:
(1) 1-COMP SINK:
(7) HAND SINK / LAVATORY:
42 x 1 = 42 GPH
5 x 1 = 5 GPH
5 x 7 = 35 GPH
TOTAL:97 GPH
(97x100% + 58) x 50 x 8.33 / 0.75 = 86,000 BTUH
PROVIDE GAS WATER HEATER WITH 120,000 BTUH
(1) MOP SINK:15 x 1 = 15 GPH
GAS INPUT
NOTES:
1
2
3
4
5
6
7
8
2"CW CONNECT TO EXISTING 2"CW MAIN BY LANDLORD.
PROVIDE 1/2"CW TO TRAP PRIMER.
FIELD VERIFY EXACT SIZE, & LOCATION.
PROVIDE 1-1/4" INLET & OUTLET FOR GAS WATER HEATER.
1/2"CW DN. TO WATER FILTRATION SYSTEM, THEN 1/2"FW TO
EXISTING 2"G FROM EXISTING GAS METER TO BE REPLACED
3/4"CW DN. TO FAUCET. SEE EQUIPMENT PLAN FOR DETAIL.
BY NEW 2-1/2"G. FIELD VERIFY EXACT SIZE, & LOCATION.
3/4"CW&HW DN., ROUTE 3/4"CW&HW TO EACH WASH SINK.
TOTAL OF 3.
EXISTING 2"CW MAIN BY LANDLORD. FIELD VERIFY EXACT
SIZE, & LOCATION.
WATER & GAS FLOOR PLAN
(1) DISHWASHER:40 GPH
(1) GLASS WASHER:18 GPH
P.O.C.
1
1-1/4" ANSUL VALVE (225 CFH)
2 4
1-1/4"G
4
1-1/4"G1"G
3
3/4"G
2" ANSUL VALVE (375 CFH)
4
1"G
5
1-1/4"G
1
1"G
1
WHA
1-1/4"G 1-1/4"G
1-1/4"G
2"G 2"G
2"G
2-1/2"G2-1/2"G55 5 5
3/4"CW
3/4"HW
3/4"HWR
3/4"HWR,HW,CW
3/4"HWR, 1"HW&CW
3/4"HWR, 1"HW&CW
1-1/2"CW
1/2"HWR
1"HW
3/4"HWR
1-1/2"CW
1"HW
2"CW
2"CW
1/2"HW
2"CW(E)2"CW(E)SOV
2
3
3
3
ICE MAKER.
4
6
7
8 8 8 8
1/2"CW UP TO ROOF WITH SOV TO MAKE-UP AIR UNIT.9
9
Job No.
Sheet No.
Plot Date
Scale
Job Begin
JO
B
N
A
M
E
4/4/2023
1
2
REVISIONS:
SH
E
E
T
T
I
T
L
E
:
MONTEREY PARK, CA 91754
Tel: (626) 476-0518
EMAIL: TIANMUS@GMAIL.COM
Interior Design
3
4
TA
I
E
R
R
E
S
T
A
U
R
A
N
T
T
.
I
.
40
0
S
O
U
T
H
B
A
L
D
W
I
N
A
V
E
.
,
S
U
I
T
E
2
3
1
AR
C
A
D
I
A
,
C
A
9
1
0
0
7
646 Armitos Place Diamond Bar, CA 91765
T: 909.569.2586 Email: bkengineers88@gmail.com
B CONSULTING ENGINEERS INCK P-3
WA
T
E
R
&
G
A
S
F
L
O
O
R
P
L
A
N