Loading...
HomeMy WebLinkAbout400 S Baldwin Ave - 2023 - Taier Mechanical & PlumbingM-1 ME C H A N I C A L L E G E N D , NO T E , & S C H E D U L E NO. EQUIPMENT SCHEDULE DESCRIPTION Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518 EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 1 AR C A D I A , C A 9 1 0 0 7 646 Armitos Place Diamond Bar, CA 91765 T: 909.569.2586 Email: bkengineers88@gmail.com B CONSULTING ENGINEERS INCK CONDENSATE DRAIN DN. DOWN SUPPLY AIR DUCT RETURN AIR DUCT EXHAUST AIR DUCT OUTSIDE AIR DUCT TRANSITION - RECTANGULAR TO RECT- TRANSITION - RECTANGULAR TO ROUND ELBOW W/TURNING VANE LINED DUCT, DUCT SIZE WITH L FOR RISE IN DIRECTION OF AIRFLOW DROP IN DIRECTION OF AIRFLOW DUCT ENCLOSURE IN GYPSUM BOARD FOR 2 HOURS RATING FLEXIBLE DUCT SUPPLY AIR DUCT - SECTION RETURN, EXHAUST, OR OUTSIDE AIR DUCT ROUND DUCT OR STACK - SECTION 12"X 12" NECK PERFORATED CEILING 6"X 6" PERFORATED CEILING REGISTER, DIFFUSER, 360 CFM OAOA T 150 CD 12X12CD 6X6R 360 150 CFM -SECTION THERMOSTAT WITH AUTOMATIC CHANGE-OVER D D R R 6X6L (L)SINGLE LINE ANGULAR GENERAL NOTES SINGLE SYMBOL DOUBLE RA EAD SA ABBREVI- RA EAD SA ATION LEGEND & VENTED LOCKABLE CLEAR COVER 1.THE DRAWINGS, SPECIFICATIONS AND GENERAL NOTES DESCRIBE THE RECOMMENDED SCOPE OF WORK AND THE DOCUMENTS SHALL BE USED FOR THE PURPOSE OF BIDDING, BUILDINGS DEPARTMENT REVIEW, AND TO SECURE THE NECESSARY CONSTRUCTION PERMIT ONLY. CONTRACTOR SHALL PROVIDE CONSTRUCTION DRAWINGS AND OBTAIN WRITTEN APPROVAL OF ALL INSPECTION AUTHORIZED GOVERNMENTAL AGENCIES AND UTILITY COMPANIES PRIOR TO START OF AFFECTED WORK. 2.ALL MECHANICAL WORK SHALL COMPLY WITH LOCAL APPLICABLE CODE AND 2022 CALIFORNIA MECHANICAL CODE. 3.COORDINATE ALL MECHANICAL WORK W/ARCHITECTURAL, ELECTRICAL STRUCTURAL, SUBCONTRACTOR & OTHER TRADES TO AVOID INTERFERENCES. 4.COORDINATE LOCATIONS OF OPENING THROUGH FLOOR, WALL & ROOF W/ARCHITECTURAL, ELECTRICAL & STRUCTURAL DRAWINGS. 5.SEAL & TAPE ALL OPENINGS IN DUCTWORK AIRTIGHT AFTER TESTING. 6.ALL SIZES FOR DUCT, GRILLE, REGISTER, DIFFUSER & LOUVER SHALL BE IN INCHES. 7.CHECK & VERIFY ALL FIELD CONDITIONS & ACTUAL DIMENSIONS BEFORE PREPARING SHOP DRAWINGS & BEGINNING INSTALLATION NOTIFY ARCHITECT IMMEDIATELY OF AND ALL DISCREPANCIES. 8.TEST & BALANCE ALL HVAC SYSTEM ACCORDING TO CFM INDICATED ON PLANS. 9.ALL APPLIANCE AND PLUMBING VENTS SHALL BE AT LEAST TEN (10) FEET IN A HORIZONTAL DIRECTION, OR THREE (3) FEET ABOVE THE OUTSIDE-AIR INTAKES FOR HVAC UNITS. 10.FACTORY-MADE FLEXIBLE DUCT & DUCT CONNECTOR TO BE U. L. 181 LISTED, & MAXIMUM 5'-0". 11.GREASE HOOD EXHAUST DUCT SHALL SLOPE NOT LESS THAN 1/4" PER LINEAR FOOT TOWARD THE HOOD SO THAT GREASE CANNOT BECOME POCKETED IN ANY PORTION OF EXHAUST DUCT. 12.PROVIDE CLEANOUT OPENING WITH TIGHT-FITTING DOOR IN GREASE DUCT AND FIRED RATED ENCLOSURE MATERIAL & CONSTRUCTION SHALL COMPLY WITH CHAPTER 5 OF CMC CURRENT EDITION. GENERAL SEISMIC NOTES ALL BRACING OF DUCTS AND PIPING SHALL BE INSTALLED IN ACCORDANCE WITH SMACNA GUIDELINES AS APPROVED BY CITY. WHERE BRACING DETAILS ARE NOT SHOWN ON THE DRAWINGS OR IN THE GUIDELINES, THE FIELD INSTALLATION SHALL BE SUBJECT TO THE APPROVAL OF THE ARCHITECT, MECHANICAL ENGINEER AND THE FIELD INSPECTOR. A COPY OF THE GUIDELINES PUBLISHED BY SMACNA AND APPROVED BY CITY SHALL BE PROVIDED BY THE CONTRACTOR AND KEPT ON THE JOB AT ALL TIMES. THE SEISMIC ANCHORAGE OF MECHANICAL AND ELECTRICAL EQUIPMENT SHALL CONFORM TO C.C.R. TITLE 24, SECTION 1630A AND TABLE 16A-K.3. ANCHORAGE DETAILS FOR ROOF/FLOOR MOUNTED EQUIPMENT WEIGHING LESS THAN 400 LBS. AND HUNG EQUIPMENT WEIGHING LESS THAN 20 LBS MAY BE OMITTED FROM THE PLANS. ALL MECHANICAL AND ELECTRICAL EQUIPMENT SHALL BE BRACED OR ANCHORED TO RESIST A HORIZONTAL FORCE ACTING IN ANY DIRECTION USING THE FOLLOWING CRITERIA: EQUIPMENT ON GRADE 23% OF OPERATING WEIGHT EQUIPMENT ON STRUCTURE 35% OF OPERATING WEIGHT FOR FLEXIBLY MOUNTED EQUIPMENT USE 2 X THE ABOVE VALUES, AND FOR SIMULTANEOUS VERTICAL FORCE USE 1/3 X THE HORIZONTAL FORCE. THE ABOVE VALUES ARE FOR AN IMPORTANCE FACTOR, I=1.15 AND SEISMIC ZONE, Z=0.4. WHERE ANCHORAGE DETAILS ARE NOT SHOWN ON THE DRAWINGS THE FIELD INSTALLATION SHALL BE SUBJECT TO THE APPROVAL OF THE MECHANICAL ENGINEER. ALL APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE SECURELY FASTENED IN PLACE PER BUILDING CODE REQUIREMENTS. SMOKE DETECTOR OVERFLOW DRAIN S SD OD EF 1 UNIT SHALL BE ELECTRICALLY INTERLOCKED WITH EF-1,2, 3 MA MAKE-UP AIR UNIT "CHAMPION" EVAPORATIVE COOLER, MODEL 10/12SD UNIT SHALL DELIVER 9,000 CFM @ 0.3 S.P. 2 H.P. MOTOR ELECTRICAL: 208V-3Ø-60HZ UNIT APPROX OPERATING WEIGHT = 731 LBS 1 KITCHEN HOOD EXHAUST FAN (GREASE) "ECON AIR" MODEL DU180HFA UPBLAST CENTRIFUGAL ROOF UNIT APPROX. WEIGHT = 181 LBS 3 HP FAN MOTOR ELECTRICAL: 208V-3Ø-60HZ UNIT SHALL DELIVER 3,600 CFM @ 1.25" SP VENTILATOR OR EQUAL AIR BALANCE SCHEDULE ITEM SUPPLY AIR RETURN AIR MAKE-UP/OUTSIDE AIR EXHAUST AIR PRESSURE MA-1 0 0 +9,000 0 +9,000 EF-1 0 0 0 -3,600 -3,600 EF-2 0 0 0 -3,600 -3,600 EF-3 0 0 0 -1,800 -1,800 EF-4 0 0 0 -800 -800 EF-5 0 0 0 -600 -600 EF-6 0 0 0 -250 -250 HP-1 600 -350 0 0 +250 HP-2 4,000 -2,600 0 0 +1,400 TOTAL +4,600 -2,950 +9,000 -10,650 0 TENANT SPACE PRESSURE =0 CFM C.B. E 208V / 3PH / 60HZ EE C.B. 208V / 3PH / 60HZ C.B. DL DL DL CC DL DL DL AUX AUX C DL DL DL 208V / 3PH / 60HZ HOOD OR ON WALL PUSH BUTTON ON E E SECTION OF PANEL NON FUSED WP-DS ON ROOF E ANSUL SYSTEM, NORMALLY CLOSED DRY CONTACT MAGNETIC STARTER IN CONTROL 12 (ON ROOF) 1 (ON ROOF)(ON ROOF) NO SCALE KITCHEN EXHAUST SYSTEM WIRING DIAGRAM EFEF MA EF 3 KITCHEN HOOD EXHAUST FAN (GREASE) "ECON AIR" MODEL DU85HFA UPBLAST CENTRIFUGAL ROOF UNIT APPROX. WEIGHT = 94 LBS 3/4 HP FAN MOTOR ELECTRICAL: 110V-1Ø-60HZ UNIT SHALL DELIVER 1,800 CFM @ 0.75" SP VENTILATOR OR EQUAL UNIT APPROX. WEIGHT = 348 LBS EXISTING PACKAGED HEAT PUMP ROOFTOP UNIT "TRANE" MODEL NO. 4WCC3018A UNIT SHALL DELIVER 600 CFM @ 0.5" ESP. 18,000 BTUH ARI RATED COOLING CAPACITY, SEER=13.0 16,800 BTUH HEATING CAPACITY, HSPF=7.70 @ 47°F ELECTRICAL: 208V-1Ø-60HZ HP OUTDOOR TEMPERATURE. MIN. OSA = 250 CFM MIN. CIRCUIT AMPACITY = 10.6 AMPS MAX. OVERCURRENT PROTECTION = 15 AMPS 1 (EXISTING)PROVIDE MERV13 FILTERS UNIT APPROX. WEIGHT = 941 LBS EXISTING PACKAGED HEAT PUMP ROOFTOP UNIT "TRANE" MODEL NO. WSC120A3 UNIT SHALL DELIVER 4,000 CFM @ 0.5" ESP. 121,000 BTUH ARI RATED COOLING CAPACITY, SEER=10.7 108,000 BTUH HEATING CAPACITY, COP=2.2 @ 47°F ELECTRICAL: 460V-3Ø-60HZ HP OUTDOOR TEMPERATURE. MIN. OSA = 1,400 CFM MIN. CIRCUIT AMPACITY = 26.4 AMPS MAX. OVERCURRENT PROTECTION = 35 AMPS 2 (EXISTING)PROVIDE ECONOMIZER, & MERV13 FILTERS ROOM THERMOSTAT NO SCALE AC UNIT CONTROL WIRING DIAGRAM E E A/C UNIT CONTROL PANEL CIRCUIT BREAKER SHALL SHUT FAN 120 V - 1 Ø - 60 Hz OPERATION DETECTION SIGNAL INTERLOCK TO SUPPLY FAN CONTACT - UPON ACTIVATION OF SMOKE DISCONNECT SWITCH DETECTOR SMOKE DUCT @ SUPPLY DUCTM EM M E M TIME CLOCK 460 VOLT - 3 PHASE - 60 HERTZ BY FIRE MARSHAL TO FACP IF REQUIRED EF 2 EF 4 KITCHEN HOOD EXHAUST FAN (NON-GREASE) "ECON AIR" MODEL DU33HFA UPBLAST CENTRIFUGAL ROOF UNIT APPROX. WEIGHT = 68 LBS 1/3 HP FAN MOTOR ELECTRICAL: 110V-1Ø-60HZ UNIT SHALL DELIVER 800 CFM @ 0.4" SP VENTILATOR OR EQUAL ROOF VENTILATOR "COOK" MODEL ACE-100C2B OR EQUAL ELECTRICAL: 120V-1Ø-60HZ, 1/6 HP MOTOR EF UNIT SHALL DELIVER 250 CFM @ 0.5" SP UNIT SHALL BE ELECTRICALLY INTERLOCKED WITH LIGHT SWITCH 6 EF 5 KITCHEN HOOD EXHAUST FAN (NON-GREASE) "ECON AIR" MODEL DU33HFA UPBLAST CENTRIFUGAL ROOF UNIT APPROX. WEIGHT = 68 LBS 1/3 HP FAN MOTOR ELECTRICAL: 110V-1Ø-60HZ UNIT SHALL DELIVER 600 CFM @ 0.4" SP VENTILATOR OR EQUAL PROVIDE BACKDRAFT DAMPER UNIT APPROX. WEIGHT = 68 LBS BAND (TYP.) 2"x16 GA. (MIN.) 3/8"Ø BOLT SWAY BRACING TO STRUCT BEAM HANGER ROD 1/2"Ø (MIN.) 6' MAX. STEEL-GALVANIZED SHEET GAUGE PER CMC 2007 TABLE 6-8 RIGID DUCT SUPPORT DETAIL N.T.S. 500 CFM LE D L E D LE D LE D L E D LE D L E D LE D LE D LE D LE D L E D LE D L E D LE D LE D LE D LE D L E D LE D L E D LE D LE D LE D LE D L E D LED LED LED LED LED LED LED LED LE D LE D LE D LE D LED LED LEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLED LEDLEDLEDLEDLED LE D LE D LE D LE D LE D LE D LE D LE D LE D LE D LE D LE D LE D LE D HVAC FLOOR PLAN 500 CFM 500 CFM 500 CFM 500 CFM 500 CFM 500 CFM 10"x10" CD 300 CFM 8"x8" CD 200 CFM 12"Ø ROUND DIFFUSER (TYP. FOR 7) 8"Ø 14"Ø 14"Ø ALL EXPOSED DUCTWORK SHALL BE RIGID AND PAINTED PER OWNER'S DIRECTION. INSTALL MIN. R-4.2 INTERNAL LINING FOR EXPOSED SUPPLY AIR DUCT. FIELD VERIFY MOUNTING HEIGHT OF DUCTWORK & REGISTERS WITH OWNER/ARCHITECT. 14"Ø 14"Ø 14"Ø14"Ø 14"Ø26"Ø 10"Ø 10"x10" CD 300 CFM 14"x14" RR 400 CFM 10"x10" CD 300 CFM 10"Ø 10"Ø 12"Ø 10"Ø 8"x8" ER 100 CFM 8"x8" ER 150 CFM S S HOOD #1 HOOD #2 HOOD #3 HOOD #4 HOOD #5 2250 CFM 2250 CFM 2250 CFM 2250 CFM 20"Ø 20"Ø 20"Ø 20"Ø26"Ø26"Ø NOTES: INSTALL NEW THERMOSTAT WITH LOCKABLE VENTED BOX 1 2 3 4 6 TO BE MOUNTED AT 48" A.F.F.. 5 EXISTING SA/RA UP TO ROOF. FIELD VERIFY EXACT SIZE, & LOCATION. PROVIDE DUCT MOUNTED SMOKE DETECTOR AT MAIN SUPPLY DUCT IF THERE IS NONE. 7 6"Ø FLUE VENT UP TO ROOF. GREASE EXHAUST DUCT, SEE PLAN FOR SIZE, UP TO ROOF, WITH THERMAL CERAMIC FIREMASTER FASTDUCT XL OR EQUAL. U. L. LISTED TYPE I GREASE HOOD, SEE M-4, & ECON-AIR PLANS FOR DETAILS. FABRICATE DUCT FROM 16 GAUGE STEEL WITH WELDED SEAM CONSTRUCTION. SEE HOOD DETAIL DRAWING ON SHEET M-3. 1 1 12 32 22 3 3 3 4 18"Ø418"Ø 4 14"Ø 5 C U 22"x22" SUPPLY DIFFUSER WITH PERFORATED FACE. 6 6 6 6 FULL SIZE MA DUCT UP TO ROOF MOUNTED MAU. 7 8 10"Ø EXHAUST DUCT UP TO ROOF. 9 10"Ø NON-GREASE EXHAUST DUCT FROM TYPE II HOOD UP TO ROOF. 10 12"Ø NON-GREASE EXHAUST DUCT FROM TYPE II HOOD UP TO ROOF. 9 10 8 36"x24" RR 2600 CFM 8"Ø6"Ø 26"Ø 24"Ø 24"Ø 16"Ø 20"Ø 14"Ø Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518 EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 1 AR C A D I A , C A 9 1 0 0 7 646 Armitos Place Diamond Bar, CA 91765 T: 909.569.2586 Email: bkengineers88@gmail.com B CONSULTING ENGINEERS INCK M-2 HV A C F L O O R P L A N HVAC ROOF PLAN EF 6 HP 1 HP 2 NOTES: 1 2 3 4 EXISTING ECONOMIZER, SET MIN. OSA = 1,400 CFM. EXISTING AC UNIT BY LANDLORD. FIELD VERIFY EXACT SIZE, LOCATION, & CONDITION. PROVIDE SERVICES TO MAINTAIN PROPER WORKING CONDITION. REPLACE TO MERV13 FILTERS 3/4" CONDENSATE DRAIN, & OVERFLOW DRAIN DN. TO MOP SINK WITH 2" AIR GAP ABOVE FLOOD RIM. EXISTING OSA INTAKE, ADJUST TO 200 CFM. AFTER FINAL INSPECTION. 1 1 MIN. 10'-0" CLEARANCE (TYP.) EF 1 EF 1 EF 3 EF 4 EF 5 MA 1 2 3 3/4"CD 3/4"CD 3/4"OD MIN. 1% SLOPE BELOW ROOF (TYP.) 4 5 Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518 EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 1 AR C A D I A , C A 9 1 0 0 7 646 Armitos Place Diamond Bar, CA 91765 T: 909.569.2586 Email: bkengineers88@gmail.com B CONSULTING ENGINEERS INCK M-3 HV A C R O O F P L A N HOOD SUPPORT TO ROOF SEE DETAIL 1/- #10 SCREW TO EACH END #10 SCREW TO EACH END 5/8" GREEN BD. HOOD SUPPORT TO ROOF SEE DETAIL 1/- 1/2"® HOOD HANGER WITH MAX. 200 LBS LOAD 6X6#1 ADD 2X6 FLAT WITH 4-16dc TOP & BOTT CHARD ROOF TRUSS DESIGNED TO INCLUDE HOOD WEIGHT H3 HOOD CONNECTION AT KITCHEN NO SCALE 2 HOOD SUPPORT CONNECTION NO SCALE 1 3 KITCHEN HOOD T-BAR DROP CEILING 10'-0" A.F.F. 6" M I N . NO SCALE HOOD TO CEILING 18 " M I N . 24 " 6'-6" A.F.F. STAINLESS STEEL PANEL AROVE THE HOOD MIN. 3" EXTENDED CEILNG Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518 EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 1 AR C A D I A , C A 9 1 0 0 7 646 Armitos Place Diamond Bar, CA 91765 T: 909.569.2586 Email: bkengineers88@gmail.com B CONSULTING ENGINEERS INCK M-4 CO D E C O M P L I A N C E D W G S , & H O O D D E T A I L S WITH SCREWS, NAILS, ETC.. AND SEAMS ON THE EXTERNAL DO NOT PENETRATE DUCT WALLS REQUIRED BY TABLE 6 E. 5. WELD OR BRAZE ALL DUCT JOINTS CONTAIN GREASE POCKETS. 7. SECTIONS OF DUCT SHALL NOT U.S. GAGE STEEL 4. THICKNESS OF DUCTS SHALL BE: 6. SUPPORT THE DUCTS AS GENERAL NOTES (N.T.S.) SURFACE. UP TO 4 SQ. FT. OVER 4 SQ. FT. DUCT AREA 14 GA. 16 GA. GENERAL - FOR ALL GREASE DUCTS PROPER OPERATION. 3. PROVIDE A SEPARATE DUCT SYSTEM FOR EACH HOOD (SEE EXCEPTION). 2. PROVIDE ADEQUATE MAKE-UP AIR FOR 1. PROVIDE ADEQUATE CLEANOUT OPENINGS FOR THOROUGH CLEANING OF DUCT SYSTEM. PLACE BY INCOMBUSTIBLE SUPPORTS. HOODS SHALL BE SECURELY FASTENED IN GENERAL - FOR ALL HOODS DRAIN TO A COLLECTING PAN WHICH IS AND THE COOKING OR HEATING SURFACE. BETWEEN LOWER EDGE OF GREASE FILTER READILY ACCESSIBLE FOR CLEANING SEE TABLE 507.11 FOR MINIMUM DISTANCE WHEN GUTTERS ARE PROVIDED THEY SHALL STAINLESS STEEL TO BE MIN. 20 MSG GALVANIZED STEEL TO BE MIN. 18 MSG OR ALL JOINTS AND SEAMS SHALL BE GREASE CONSTRUCTION AND READILY ACCESSIBLE GREASE FILTERS SHALL BE OF STEEL FOR CLEANING. TIGHT. HORIZONTAL SUPPORT DETAIL (N.T.S.)VERTICAL SUPPORT DETAIL (N.T.S.)GREASE DUCT WRAP DETAIL (N.T.S.)ACCESS DOOR DETAIL EXHAUST FAN 1. TYPE : CANOPY TYPE I, STAINLESS STEEL 20 GAUGE, HOOD #1, #2: (2) CHINESE WOK, PASTA COOKER, NOODLE COOKER 2,037 FPM < 2,500FPM 7. EXHAUST VELOCITY @ EXHAUST DUCT 8. EXHAUST FAN AND MAKE-UP AIR UNIT EF-1, EF-2 (3,600 CFM EACH), EF-3 (1,800 CFM); MA-1 (9,000 CFM) 5. PROPOSED (3) EXHAUST FAN & (1) MAKE-UP AIR UNIT SHALL BE ELECTRICALLY INTERLOCKED HOOD #1, #2: U.L. LISTED HOOD WITH 3,600 CFM EACH 3,600/(8"x8"x3.14/144)= 2,037 FPM 4. MIN. REQ'D CAPACITY CFM 9. FOR CODE COMPLIANCE SEE DETAIL 6. EXHAUST DUCT SIZE: 2. COOKING EQUIPMENT AS FOLLOW: EF-1, EF-2, EF-3 MAKE-UP AIR MA-1 HOOD #1, #2: 12'-0" x 4'-6" EACH3. SIZE: NO. OF FILTERS: SEE ECON AIR PLANS 10. FILTER SIZE: 20"x16"x2" HOOD #1, #2: HOOD #1, #2: 18"Ø (N.T.S.)(N.T.S.) PLAN CHECK NOTES: 1.FIELD APPLIED OR FACTORY BUILT GREASE DUCT ENCLOSURE SHALL BE INSTALLED PER THE LATEST MANUFACTURER'S INSTALLATION INSTRUCTIONS AND IN COMPLIANCE WITH TERMS OF ITS LISTING. 2.ALL END CUTS OR CUTS IN THE FOIL JACKET OF FIELD APPLIED GREASE DUCT ENCLOSURE SHALL BE SEALED PER THE MANUFACTURER'S RECOMMENDATIONS. 3.ALL INSTALLATIONS SHALL BE COMPLETELY ACCESSIBLE FOR VISUAL INSPECTION. 4.AT TIME OF INSPECTION, THE FIELD APPLIED OR FACTORY BUILT GREASE DUCT ENCLOSURE INSTALLATION INSTRUCTIONS SHALL BE MADE AVAILABLE AT THE JOT SITE. 5.LISTED GREASE HOOD ASSEMBLIES SHALL BE INSTALLED IN ACCORDANCE WITH THE TERMS OF THEIR LISTING AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 6.FIRE DEPARTMENT APPROVAL SHALL BE REQUIRED ON FIRE PROTECTION SYSTEM FOR GREASE HOODS AND DUCTS AS REQUIRED BY SECTION 513 OF THE CALIFORNIA MECHANICAL CODE AND AS REQUIRED BY THE FIRE CODE. 7.ALL FIRE-EXTINGUISHING SYSTEMS SHALL BE INTERCONNECTED TO THE FUEL OR CURRENT SUPPLY SO THAT THE FUEL OR CURRENT IS AUTOMATICALLY SHUT OFF TO ALL EQUIPMENT UNDER THE HOOD WHEN THE SYSTEM IS ACTIVATED. 8.OWNER OF ESTABLISHMENT SHALL BE RESPONSIBLE FOR CLEANLINESS, MAINTENANCE, AND INSPECTION OF KITCHEN EXHAUST SYSTEM, FIRE PROTECTION, AND COOKING EQUIPMENT. 9.A DRAWING OF THE EXHAUST SYSTEM(S) INSTALLATION ALONG WITH A COPY OF OPERATING INSTRUCTIONS FOR SUBASSEMBLIES AND COMPONENTS USED IN THE EXHAUST SYSTEM(S), INCLUDING ELECTRICAL SCHEMATICS, SHALL BE AVAILABLE ON THE PREMISES. 10.ALL SEAMS, JOINTS, AND PENETRATIONS OF THE HOOD ENCLOSURE THAT DIRECT AND CAPTURE GREASE-LADEN VAPORS AND EXHAUST GASES SHALL HAVE A LIQUID TIGHT CONTINUOUS EXTERNAL WELD TO THE LOWER OUTERMOST PERIMETER OF THE HOOD. 11.HOOD EXHAUST FAN SHALL CONTINUE TO OPERATE AFTER THE EXTINGUISHING SYSTEM HAS BEEN ACTIVATED, UNLESS FAN SHUTDOWN IS REQUIRED BY A LISTED COMPONENT OF THE VENTILATION SYSTEM. 12.DUCTS (OTHER THAN LISTED GREASE DUCT) SHALL BE CONSTRUCTED OF AND SUPPORTED BY CARBON STEEL NOT LESS THAN 0.060" (NO. 16 MSG) IN THICKNESS OR STAINLESS STEEL NOT LESS THAN 0.048" (NO. 18 MSG) IN THICKNESS. HOOD #3: 8'-0" x 4'-6" HOOD #3: U.L. LISTED HOOD WITH 1,800 CFM 1,800/(7"x7"x3.14/144)= 1,684 FPM 1,684 FPM < 2,500FPM HOOD #3: HOOD #2: 14"Ø REMOVABLE GREASE FILTER W/ HANDLES AUTO FIRE EXTINGUISHER (SEPARATE 6" TYP. @ ALL OPEN SIDES PERMIT BY FIRE EXTINGUISHER CO.) MTL. WALL FLASHING 24 GA. S/S SHEET MTL. FIN. FLOOR 3" MIN. METAL STUD WALL W/ 5/8" TYPE "X" GYP. BD. ON BOTH SIDE EQUIPMENT COOKING 3" MIN. 48" - 1 16 GA. GI. DUCT MTL. HOOD 22 GA. S/S ROOF DECK EXTENDED FIRE RATED 18" BELOW CEILING, WHEN HOOD IS LESS THAN HOOD ON BOTH SIDE CEILING 18" BEYOND THE CEILING MTL. WALL FLASHING 24 GA. COOKING EQUIPMENT 6" MIN. 6" 7'-0" S/S SHEET MTL. FIN. FLOOR 6" MIN, W/ REMOVABLE GREASE FILTER TYP. HOOD LIGHT W/ SHIELD INSIDE HOOD, AUTO FIRE EXTINGUISHER (SEPARATE PERMIT BY FIRE EXTINGUISHER CO.) UL APPROVED (IF INSTALLED) 12" FROM CEILING MUST BE FLASHED SOLID HOOD LESS THAN 48" GREASE CONTAINER 20 GA. S/S MTL. HOOD ROOF DECK 18" 10' FROM ADJACENT BUILDINGKEEP MIN. 10' AWAY FROM ADJACENT BLDG OR BLDG OSA INTAKE OPENING AROUND FAN CODE APPROVED GREASE PORT AIR IN TAKE OPENING 10' ABOVE GRADE LEVEL 10' FROM PROPERTY LINE & 48" MIN. BLOWER 16 GA. GI. DUCT 24" MIN. 2-LAYER DUCT WRAP MIN. 18" 2-LAYER DUCT WRAP WITH COLLECTION TROUGH OR CARTRIDGE HOOD #1, #2: STOCK POT RANGE, RICE COOKER, (2) DEEP FRYER W/ YB VTR TYP. VENT THROUGH ROOF YARD BOX WITH TYPICAL TEMP. PLBG GPM CONT. FLR. DN. PLUMBING TEMPERATURE GALLONS PER MINUTE CONTINUATION FLOOR DOWN PLUMBING EQUIPMENT DESIGNATION PLUMBING FIXTURE DESIGNATION SANITARY SEWER OR WASTE BELOW GRADE/FLOOR SANITARY SEWER OR WASTE ABOVE GRADE/FLOOR AP ABV WC - 1 E WH EXIST`G FS FD ACCESS PANEL ABOVE EXISTING FLOOR SINK FLOOR DRAIN GV U POC GLV STR G WHA WCO COTG G FCO GATE VALVE GLOBE VALVE POINT OF CONNECTION GAS OR GATE COCK UNION STRAINER WATER HAMMER ARRESTOR WALL CLEANOUT FLOOR CLEANOUT CLEANOUT TO GRADE NATURAL GAS PLUMBING LEGEND S OR W D V CW HW D V SYMBOL ABBREV. S OR W INDIRECT DRAIN SANITARY VENT DOMESTIC COLD WATER DOMESTIC HOT WATER DEFINITION NON-RESIDENTIAL ENERGY CONSERVATION STANDARDS NOTE : STANDARDS. STANDARD. STANDARD. 1. PIPING INSULATION SHALL COMPLY WITH CEC BUILDING ENERGY EFFICIENCY 2. ALL PLUMBING EQUIPMENT SHALL BE CERTIFIED PER CEC BUILDING EFFICIENCY 3. THE "MANDATORY MEASURES" OF THE ENERGY EFFICIENCY STANDARD HAVE BEEN REVIEWED AND THE DESIGN, DRAWINGS AND CALCULATIONS COMPLY WITH THESE RPPBFP REDUCE PRESSURE PRINCIPLE BACKFLOW PREVENTER OVERHEAD C.W. SUPPLY TRAP PRIMER TYPICAL TRAP PRIMER DETAIL NO SCALE GRAVITY LINE TO TRAP C.W. SUPPLY FINISH FLOOR VACUUM BREAKER UNION NOTE: PROVIDE TRAP PRIMER CONNECTION W/ AIR GAP REQUIRED PER 2022 UPC SEC.603,3 MIN. 1" AIR GAP PROVIDED & INSTALLED BY PLUMBING CONTRACTOR. ALL EQUIPMENT SHALL BE APPROVED PROVIDED BY OWNER/EQUIPMENT COMPANY, INSTALLED BY PLUMBING CONTRACTOR. 1 2 FS 1 1 S 2 FLOOR SINK 3"HALF GRATE, "ZURN" OR EQUAL2"2"1 PIPE CONNECTION PLUMBING FIXTURE SCHEDULE TRAPSYMBOL S FIXTURE TYPE WASTE DESCRIPTIONVENTCWHW 2""JR. SMITH" 2005 TRAPPED WITH TRAP PRIMER 1FLOOR DRAINFD 1 1-1/2"1-1/2" (WALL MOUNTED)2"1-1/2"1-1/2"1/2"1/2"HAND SINK SEE KITCHEN DWGS FOR EQUIPMENT & FAUCET MODEL 2 ALL PLUMBING FIXTURES SHALL BE LISTED AND LABELED.3 3 BY THE ARCHITECT AND OWNER. (1 COMP. SINK) PREP. SINK SEE KITCHEN DWGS FOR EQUIPMENT & FAUCET MODEL 23/4"3/4"FS 11 GWH GAS WATER HEATER 120,000 GAS INPUT, EF: 0.8 "A O SMITH" BTL-120, 80 GAL. TANK CAPACITY Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518 EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 1 AR C A D I A , C A 9 1 0 0 7 646 Armitos Place Diamond Bar, CA 91765 T: 909.569.2586 Email: bkengineers88@gmail.com B CONSULTING ENGINEERS INCK 192 GPH REC. @ 60°F RISE L 1 (DISABLED)2"1-1/2"1-1/2"LAVATORY A/S WALL MOUNTED, WHITE VITREOUS CHINA, WC 1 (DISABLED)4"2"INTWATER CLOSET A/S FLOOR MOUNTED, FLUSH VALVE, MAX 1.28 GPF, ELONGATED, ADA COMPLIANT, OPEN FRONT SEAT W/ LESS COVER, WHITE VITREOUS CHINA SELF-CLOSING FAUCETS, MAX. 0.25 GPM, WITH MIXING VALVE SET @ 110°F MAX. ADA COMPLIANT 1/2"1/2" UR 1 (DISABLED)2"1-1/2"1-1/2"URINAL FLUSH VAVLE, MAX. 0.125 GPF, ADA COMPLIANT, WHITE VITREOUS CHINA, 1-1/2" 1-1/4" 3 S 3"2"2"MOP SINK PROVIDE NON-REMOVABLE VACUUM BREAKER3/4"3/4"SELECTED BY OWNER 1 1 1 2 (E) 2 41 NEW F.U. 56 TOTAL F.U. GPM CFH F.U. INCH INCH INCH(E) (2) 4 SIZE MAIN CAPACITY SERVICE DOMESTIC WATER SANITARY SEWER SERVICE FUEL GAS DOMESTIC WATER SANITARY SEWER FIXTURE UNIT SUMMARY SERVICE REQUIREMENTS OLD F.U. 0 0 47 56 720 41 56 2-1/2 * SEE FIXTURE UNIT TABLE FOR DETAIL 4 S 5 S 1 DW (3 COMP. SINK) POT SINK SEE KITCHEN DWGS FOR EQUIPMENT & FAUCET MODEL 23/4"3/4" WASH SINK SEE KITCHEN DWGS FOR EQUIPMENT & FAUCET MODEL 2 3/4"DISHWASHER SEE KITCHEN DWGS FOR EQUIPMENT & FAUCET MODEL 2FS FS 2 FLOOR SINK HALF GRATE, "ZURN" OR EQUAL 12"1-1/2"1-1/2" SERVICE COLD & HOT WATER SANITARY VENT SANITARY WASTE "NO-HUB" CAST IRON OR ABS * "NO-HUB" CAST IRON OR ABS * GALV. STEEL, SCHEDULE 40/ "NO-HUB" CAST IRON ABOVE GROUND HARD DRAWN COPPER TUBEHARD DRAWN COPPER TUBE UNDERGROUND PIPE MATERIAL SCHEDULE TYPE "K" OR "L"TYPE "L" ** "NO-HUB" CAST IRON NOTE: * ABS MAY BE USED ONLY WITH OWNER AND LOCAL AUTHORITY APPROVAL. OR ABS * OR ABS * GAS BLACK STEEL, SCHEDULE 40 INDIRECT DRAIN HARD DRAWN COPPER TUBE TYPE "M" ** CPVC, & PEX MAY BE USED ONLY WITH OWNER AND LOCAL AUTHORITY APPROVAL. N.T.S. SEDIMENT TRAP MIN.3" (80mm) GAS SUPPLY INLET TEE FITTING TO EQUIPMENT INLET NIPPLE CAP 1 WHA WATER HAMMER ARRESTOR 1""C", FIXTURE UNIT RATING : 61-113 "JR. SMITH" MODEL: 5020, P.D.I. SYMBOLS MIN. 1,250 GAL. CAPACITY REQUIRED PER 2022 CPC. EXISTING 1,500 GAL. GREASE INTERCEPTOR PROVIDED BY LANDLORD. GREASE INTERCEPTOR CALCULATION FIXTURE QUANTITY SEWER FU EACH SEWER FU TOTAL FLOOR SINK 6 3 18 FLOOR SINK 1 1 1 HAND SINK 1 1 1 3-COMP SINK 1 3 3 MOP SINK 1 3 3 FLOOR DRAIN 3 2 6 TRENCH DRAIN 1 3 3 TOTAL 35 1 3"2"2" 1-1/4"1-1/4" 1 CP CIRCULATING PUMP 5 GPM @ 10FT HD., 1/12 HP MOTOR. IN-LINE HOT WATER CIRCULATING PUMP,3/4"1 P-1 PL U M B I N G L E G E N D , NO T E , & S C H E D U L E 1 GW 3/4"GLASS WASHER SEE KITCHEN DWGS FOR EQUIPMENT & FAUCET MODEL 2FS PLUMBING GENERAL NOTES 1.THE PLUMBING SYSTEM SHALL COMPLY WITH THE 2022 CALIFORNIA PLUMBING CODE. 2.DRAWING AND SPECIFICATIONS GOVERN WHERE THEY EXCEED CODE REQUIREMENTS. 3.CONTRACTOR SHALL VERIFY LOCATION AND DEPTH OF UTILITIES AT POINT OF CONNECTION BEFORE START OF WORK. 4.REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF PLUMBING FIXTURES. 5.ALL UNDERGROUND SHUT OFF VALVES OUTSIDE OF BUILDING SHALL BE IN CONCRETE BOXES WITH THE NAME OF THE SERVICE CASTED IN THE COVER. 6.ALL PLUMBING FIXTURES AND EQUIPMENT SHALL HAVE ISOLATING VALVES ON WATER SUPPLY LINES. VALVE SHALL BE LINE SIZE, UNLESS NOTED OTHERWISE. 7.ALL PLUGGED TEES AND PLUGGED WYES SHALL BE LINE SIZE, UNLESS NOTED OTHERWISE. 8.ALL PIPING PENETRATING WALL, CEILING, AND FLOOR SHALL BE ISOLATED FROM BUILDING STRUCTURES WITH RESILIENT SEALS. 9.RUN ALL INDOOR PLUMBING PIPING CONCEALED IN WALL OR ABOVE CEILING, UNLESS NOTED OTHERWISE. 10.PROVIDE DIELECTRIC UNIONS AT BIMETALLIC PIPE JOINTS. 11.PROVIDE CHROME PLATED CAPS FOR WALL CLEANOUTS. 12.WASTE LINE SHALL BE SLOPED NOT LESS THAN 1/4" PER FT. IN THE DIRECTION OF FLOW. 13.ALL VALVES AND COCKS SHALL BE LOCATED TO BE READILY ACCESSIBLE. WHERE VALVES ARE INSTALLED WITHIN OR BEHIND WALLS OR CEILING, ACCESS PANEL SHALL BE INSTALLED. 14. WATER SUPPLY AND DRAIN PIPES UNDER ACCESSIBLE LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE BE CONFIGURED TO PROTECT AGAINST CONTACT. PROTECTORS, INSULATORS, OR BOTH SHALL COMPLY WITH ASME A112.18.9. 15.EACH VENT SHALL TERMINATE NOT LESS THAN 10 FT. FROM, OR AT LEAST 3 FT. ABOVE ANY WINDOW, DOOR, OPENING AIR INTAKE OR VENT SHAFT, NOR LESS THAN 3 FT. IN EVERY DIRECTION FROM ANY LOT LINE; ALLEY AND STREET EXCEPTED. 16.ALL REQUIRED CLEANOUTS SHALL BE INSTALLED AS PER SEC. 707.0 & 719.0 OF THE PLUMBING CODE. 17.EACH VENT SHALL RISE VERTICALLY TO A POINT NOT LESS THAN SIX (6) INCHES IN HEIGHT ABOVE THE FLOOD LEVEL RIM OF THE FIXTURE BEFORE BEING CONNECTED TO ANY OTHER VENT. 18.NEW OR REPAIRED POTABLE WATER SYSTEMS SHALL BE DISINFECTED PRIOR TO USE ACCORDING TO THE METHOD SET IN SECTION 609.9 OF THE PLUMBING CODE. 19.PLUMBING FIXTURES SHALL BE CERTIFIED BY CEC. (WATER CLOSET 1.28 GPF, URINAL 0.125 GPF, SHOWER HEAD 2.0 GPM, COMMERCIAL SINK FAUCETS 1.8 GPM, LAVATORY(METERING) 0.2GPM.) 20.PROVIDE NON-LEAD SOLDER FOR POTABLE WATER PIPING JOINTS AND CONNECTION. 21.MAX. HOT WATER TEMPERATURE TO PUBLIC LAVATORIES TO BE 110°F & MIN. HOT WATER TEMPERATURE TO KITCHEN FIXTURES TO BE 120°F. 22.FLOOR DRAIN OR SIMILAR TRAPS DIRECTLY CONNECTED TO THE DRAINAGE SYSTEM AND SUBJECT TO INFREQUENT USE SHALL BE PROVIDED WITH TRAP PRIMING. TRAP PRIMING DEVICES SHALL BE ACCESSIBLE FOR MAINTENANCE.(SECTION 1007 CPC) 23.COMBUSTIBLE PIPING INSTALLATIONS SHALL BE INSTALLED PER CHAPTER 14 OF THE CALIFORNIA PLUMBING CODE FOR "FIRESTOP PROTECTION." 24.PROPOSED ADDITION, ALTERATION, OR IMPROVEMENT REQUIRES ALL NON-COMPLIANT FIXTURES TO BE REPLACED WITH WATER CONSERVING PLUMBING FIXTURE. 25.CONDENSATE DRAIN ARE TRAPPED IN ACCORDANCE WITH THE APPLIANCE MANUFACTURER'S INSTRUCTION. 26.PROTECT RECEPTOR ON ROOF OR OUTSIDE OF BUILDING FROM RAIN WATER BY ELEVATING THE RIM TWO (2) INCHES ABOVE ADJACENT SURFACE. 27.PUBLIC LAVATORIES SHALL HAVE A WATER TEMPERING DEVICE THAT COMPLIES WITH ASSE 1070 OR CSA B125.3. WATER HEATER THERMOSTAT SHALL NOT BE CONSIDERED A CONTROL TO MEET THIS PROVISION. 28.INSULATION OF DOMESTIC HOT WATER PIPING SHALL BE IN ACCORDANCE WITH SECTION 609.11.1 AND SECTION 609.11.2. 29.INDIRECT WASTE PIPING FROM FOOD HANDLING FIXTURES OR EQUIPMENT SHALL BE SEPARATELY PIPED BY MEANS OF AN AIR GAP TO THE INDIRECT WASTE RECEPTOR & SHALL NOT BE COMBINED WITH ANY OTHER INDIRECT WASTE PIPING. CPC 801.3. 30.POTABLE WATER SUPPLY TO BEVERAGE DISPENSERS, CARBONATORS OR COFFEE MACHINES SHALL BE PROTECTED BY AN AIR GAP OR A VENTED BACKFLOW PREVENTER IN ACCORDANCE WITH ASSE 1022. CPC 603.5.12. 31.ICE MACHINES, DRINK DISPENSERS, COFFEE MACHINES, FREEZER, REFRIGERATION COILS, & SIMILAR EQUIPMENT SHALL BE INDIRECTLY CONNECTED TO THE DRAINAGE SYSTEM. CPC 801.3 32.ALL EXPOSED GAS PIPING SHALL BE PROTECTED AGAINST CORROSION BY COATING OR WRAPPING WITH AN INERT MATERIAL APPROVED FOR SUCH APPLICATIONS. CPC 1210.2 DRAIN VALVE NO SCALE GAS WATER HEATER DETAIL "AMTROL" THREM-X-TROL THERMAL EXPANSION TANK OR APPROVED EQUAL. 5 GAL. CHECK VALVE GATE VALVE C.W. SUPPLY H.W. TO SYSTEM PRESS & TEMP RELIEF SPILL TO MS-1 TIMECLOCK 120V C.B. AQUASTAT CP-1 GAS SUPPLY GAS COCK UNION %%uGWH-1 CP-1 AQUASTAT 3/4" W.H.R. THERMOMETER STPAPING FLUE THRU ROOF TO APPROVED VENI CAP (COLD WATER) F.U. @ psi F.U. @ psi F.U. @ psi F - TANK (E) COLD WATER PIPE SIZING CHART 28 12 MAX. 8 19.0 9.0 3.0 3 FT/SECGPMVELOCITYPIPE SIZE 1/2" 1" 3/4" 10.0 FIXTURE UNITS F - VALVE F.U. @ psi F.U. @ psi F.U. @ psi F.U. @ psi5631.01-1/4"F.U. @ psi (HOT WATER) F.U. @ psi F.U. @ psi F.U. @ psi F - TANK (E) HOT WATER PIPE SIZING CHART 28 8 MAX. 5 19.0 7.0 3.0 3 FT/SECGPMVELOCITYPIPE SIZE 1/2" 3/4" 10.0 FIXTURE UNITS F - VALVE F.U. @ psi F.U. @ psi F.U. @ psi F.U. @ psi44.01-1/2"F.U. @ psi10335 F.U. @ psi1612.01"F.U. @ psi 1-1/4" 14 F.U. @ psi76.0 F.U. @ psi2541322" 1/4" HOLES ON FOR VENTILATION 3/4" CENTERS ROOF RAFTERS WALL FLUE TYPE "B" DOUBLE PLYWOOD ROOF MATERIAL 1" CLEARANCE BETWEEN FLUE AND COMBUSTIBLE FLUE VENT DETAIL NO SCALE VENT CAP SHIELD FLASHING WEATHER 24" DOUBLE JOISTS AROUND OPENING 3/4"3/4"FS TD 1 TRENCH DRAIN 3" "ZURN" MODEL Z886 OR EQUAL, 8'-0" EACH, SEE PLAN FOR EXACT LENGTH, & OUTLET LOCATION, 2"2"6" WIDE FULL GRATE 打单机打单机 打单机 打单 机 W/T 干手机 纸巾盒 mopLocker LE D L E D LE D 变压 器 4" CO 4" CO 3" CO 3" CO 3" CO 1 FD 1 WC 1 UR 1 L 1 L 1 WC 1 S 1 FS 5 2 S 3 S 4 S 3 S 5 S 1 FS 5 1 FD 1 FD 1 TD 1 FS 1 FS 1 FS 1 FS 1 FS 2 FS FIXTURE WASTE FU FIXTURE TYPE QTY EACH TOTAL WATER CLOSET 2 4 8 URINAL 1 2 2 LAVATORY 2 1 2 1-COMP SINK 1 FS # 3-COMP SINK 1 3 3 HAND SINK 2 1 2 MOP SINK 1 3 3 WASH SINK 3 FS # DISHWASHER 1 FS # GLASS WASHER 1 FS # FLOOR SINK 8 3 24 FLOOR SINK 1 1 1 FLOOR DRAIN 4 2 8 TRENCH DRAIN 1 3 3 TOTAL 56 WC 1 UR 1 L 1 S 1 S 2 S 3 S 4 S 5 DW 1 GW 1 FS 1 FS 2 FD 1 TD 1 NOTE: OF NEW WORK TO BE COMPLETED BEFORE SUBMITTING BIDS. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, & EXTENT DRAWINGS ARE ONLY AN APPROXIMATION OF EXISTING CONDITIONS, NOTES: 3/4" FROM T&P VALVE DRAIN TO MOP SINK WITH 2" AIR GAP ABOVE FLOOD RIM. 1 2 3 4 5 6 EXISTING 4" SANITARY SEWER / GREASE SEWER BY LANDLORD. PROVIDE MIN. 2" INDIRECT DRAIN FROM SINK / DISHWASHER TO FLOOR SINK WITH 2" AIR GAP. PROVIDE MIN. 1" INDIRECT DRAIN FROM APPLIANCE TO FLOOR SINK WITH 2" AIR GAP. SEE EQUIPMENT PLANS FOR DETAIL. 3"V CONNECT TO EXISTING 3"V BY LANDLORD. FIELD VERIFY EXACT SIZE, & LOCATION. 4" SANITARY SEWER / GREASE SEWER CONNECT TO EXISTING 4" SANITARY SEWER / GREASE SEWER BY LANDLORD. FIELD VERIFY FIELD VERIFY EXACT SIZE, LOCATION, & DEPTH. WASTE & VENT FLOOR PLAN P.O.C.3 P.O.C.3 P.O.C.4 MIN. 2% SLOPE (TYP.) 1 DW 5 1 GW 5 1 FD (E) 4"GS (E) 4"S 4"GS 4"S 4"S 4"S 4"S 3"S 3"S 3"S 3"S 3"GS 3"GS 2"GS3"GS3"GS3"GS 3"GS 2"GS4"GS 4"GS 4"GS 3"GS 3"GS 3"GS 3"GS 2"GS 2"S 3"GS 4"S 2"S 2"S 2"V2"V 2"V2"V 3"GS 2-1/2"V 2-1/2"V 2"V 2"V3"V 2-1/2"V 2"V 2"V 2"V 2"V 3"V 1 1 GWH EXACT SIZE, LOCATION, DEPTH, & DIRECTION. 2 2 6 6 7 EXISTING 4" GREASE SEWER CONTINUE & CONNECT TO EXISTING GREASE INTERCEPTOR BY LANDLORD. FIELD VERIFY EXACT SIZE, & LOCATION, MIN. 1,250 GAL. REQUIRED. 7 Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518 EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 1 AR C A D I A , C A 9 1 0 0 7 646 Armitos Place Diamond Bar, CA 91765 T: 909.569.2586 Email: bkengineers88@gmail.com B CONSULTING ENGINEERS INCK P-2 WA S T E & V E N T F L O O R P L A N 打单机打单机 打单机 打单 机 W/T 干手机 纸巾盒 mopLocker LE D L E D LE D 变压 器 1 WC 1 UR 1 L 1 L 1 WC 1 S 2 S 3 S 4 S 3 S 5 S 1 DW 1 GW 1 GWH 1 CP FIXTURE WATER FU FIXTURE TYPE QTY EACH TOTAL WATER CLOSET 2 5 10 URNIAL 1 2 2 LAVATORY 2 1 2 1-COMP SINK 1 3 3 3-COMP SINK 1 3 3 HAND SINK 2 1 2 MOP SINK 1 3 3 WASH SIHNK 3 2 6 DISHWASHER 1 2 2 GLASS WASHER 1 2 2 ICE MAKER 1 1 1 WOK FAUCET 4 1 4 MAKE-UP AIR UNIT 1 1 1 TOTAL 41 WC 1 UR 1 L 1 S 1 S 2 S 3 S 4 S 5 DW 1 GW 1 CFH ITEM Q'TY EQUIPMENT 1,000 BTUH/EACH EACH TOTAL 1 WATER HEATER 120 120 120 1 SOUP POT RANGE 100 100 100 1 RICE COOKER 35 35 35 2 DEEP FRYER 120 120 240 1 WOK RANGE 150 150 150 1 WOK RANGE 75 75 75 TOTAL 720 1 2 3 4 5 6NOTE: OF NEW WORK TO BE COMPLETED BEFORE SUBMITTING BIDS. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, & EXTENT DRAWINGS ARE ONLY AN APPROXIMATION OF EXISTING CONDITIONS, HOT WATER CALCULATION: (1) 3-COMP SINK: (1) 1-COMP SINK: (7) HAND SINK / LAVATORY: 42 x 1 = 42 GPH 5 x 1 = 5 GPH 5 x 7 = 35 GPH TOTAL:97 GPH (97x100% + 58) x 50 x 8.33 / 0.75 = 86,000 BTUH PROVIDE GAS WATER HEATER WITH 120,000 BTUH (1) MOP SINK:15 x 1 = 15 GPH GAS INPUT NOTES: 1 2 3 4 5 6 7 8 2"CW CONNECT TO EXISTING 2"CW MAIN BY LANDLORD. PROVIDE 1/2"CW TO TRAP PRIMER. FIELD VERIFY EXACT SIZE, & LOCATION. PROVIDE 1-1/4" INLET & OUTLET FOR GAS WATER HEATER. 1/2"CW DN. TO WATER FILTRATION SYSTEM, THEN 1/2"FW TO EXISTING 2"G FROM EXISTING GAS METER TO BE REPLACED 3/4"CW DN. TO FAUCET. SEE EQUIPMENT PLAN FOR DETAIL. BY NEW 2-1/2"G. FIELD VERIFY EXACT SIZE, & LOCATION. 3/4"CW&HW DN., ROUTE 3/4"CW&HW TO EACH WASH SINK. TOTAL OF 3. EXISTING 2"CW MAIN BY LANDLORD. FIELD VERIFY EXACT SIZE, & LOCATION. WATER & GAS FLOOR PLAN (1) DISHWASHER:40 GPH (1) GLASS WASHER:18 GPH P.O.C. 1 1-1/4" ANSUL VALVE (225 CFH) 2 4 1-1/4"G 4 1-1/4"G1"G 3 3/4"G 2" ANSUL VALVE (375 CFH) 4 1"G 5 1-1/4"G 1 1"G 1 WHA 1-1/4"G 1-1/4"G 1-1/4"G 2"G 2"G 2"G 2-1/2"G2-1/2"G55 5 5 3/4"CW 3/4"HW 3/4"HWR 3/4"HWR,HW,CW 3/4"HWR, 1"HW&CW 3/4"HWR, 1"HW&CW 1-1/2"CW 1/2"HWR 1"HW 3/4"HWR 1-1/2"CW 1"HW 2"CW 2"CW 1/2"HW 2"CW(E)2"CW(E)SOV 2 3 3 3 ICE MAKER. 4 6 7 8 8 8 8 1/2"CW UP TO ROOF WITH SOV TO MAKE-UP AIR UNIT.9 9 Job No. Sheet No. Plot Date Scale Job Begin JO B N A M E 4/4/2023 1 2 REVISIONS: SH E E T T I T L E : MONTEREY PARK, CA 91754 Tel: (626) 476-0518 EMAIL: TIANMUS@GMAIL.COM Interior Design 3 4 TA I E R R E S T A U R A N T T . I . 40 0 S O U T H B A L D W I N A V E . , S U I T E 2 3 1 AR C A D I A , C A 9 1 0 0 7 646 Armitos Place Diamond Bar, CA 91765 T: 909.569.2586 Email: bkengineers88@gmail.com B CONSULTING ENGINEERS INCK P-3 WA T E R & G A S F L O O R P L A N