HomeMy WebLinkAbout400 S Baldwin Ave - 2023 - PacsunSANTA ANITA #37 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 CALGREEN NON-RESIDENTIAL NOTES BUILDING MATERIALS ·ADHESIVES, SEALANTS AND CAULKS SHALL MEET THE REQUIREMENTS OF THE FOLLOWING STANDARDS: [CALGREEN 5.504.4.1] 1)ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS, SEALANT PRIMERS, AND CAULKS SHALL COMPLY WITH LOCAL OR REGIONAL AIR POLLUTION CONTROL OR AIR QUALITY MANAGEMENT DISTRICT RULES WHERE APPLICABLE, OR SCAQMD RULE 1168 VOC LIMITS, AS SHOWN IN 2019 CALGREEN TABLES 5.504.4.1 AND 5.504.4.2. 2)AEROSOL ADHESIVES, AND SMALLER UNIT SIZES OF ADHESIVES, AND SEALANT OR CAULKING COMPOUNDS (IN UNITS OF PRODUCT, LESS PACKAGING, WHICH DO NOT WEIGH MORE THAN ONE POUND AND DO NOT CONSIST OF MORE THAN 16 FLUID OUNCES) SHALL COMPLY WITH STATEWIDE VOC STANDARDS AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS, OF CALIFORNIA CODE OF REGULATIONS (CCR), TITLE 17, COMMENCING WITH SECTION 94507. ·A LETTER FROM THE CONTRACTOR AND OR THE BUILDING OWNER CERTIFYING WHAT MATERIAL HAS BEEN USED AND ITS COMPLIANCE WITH THE CODE MUST BE SUBMITTED TO THE BUILDING INSPECTOR. ·ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH 2019 CALGREEN, TABLE 5.504.4.3. [CALGREEN 5.504.3] ·AEROSOL PAINTS AND COATINGS SHALL MEET THE PWMIR LIMITS FOR ROC IN SECTION 94522(A) (3) AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS AND OZONE DEPLETING SUBSTANCES, IN SECTIONS 94522(C) (2) AND (D)(2) OF CCR, TITLE 17, COMMENCING WITH SECTION 94520." [CALGREEN 5.504.4.3.1] ·A LETTER FROM THE CONTRACTOR AND OR THE BUILDING OWNER CERTIFYING WHAT PAINT HAS BEEN USED AND ITS COMPLIANCE WITH THE CODE MUST BE SUBMITTED TO THE BUILDING INSPECTOR." ·ALL CARPET SHALL MEET AT LEAST ONE OF THE FOLLOWING TESTING AND PRODUCT REQUIREMENTS: [CALGREEN 5.504.4.4] 3)CARPET AND RUG INSTITUTES' GREEN LABEL PLUS PROGRAM. 4)COMPLIANT WITH THE VOC-EMISSION LIMITS AND TESTING REQUIREMENTS SPECIFIED IN THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH STANDARD METHOD FOR TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS, VERSION 1.1, FEBRUARY 2010 (ALSO KNOWN AS CDPH STANDARD METHOD V1.1 OR SPECIFICATION 01350). 5)NSF/ANSI 140 AT THE GOLD LEVEL OR HIGHER. 6)SCIENTIFIC CERTIFICATION SYSTEMS SUSTAINABLE CHOICE. 7)COMPLIANCE WITH THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS CALIFORNIA (CA-CHPS) CRITERIA INTERPRETATION FOR EQ 7.0 AND 7.1 DATED JULY 2012 AND LISTED IN THE CHPS HIGH PERFORMANCE PRODUCT DATABASE ·ALL CARPET CUSHION SHALL MEET THE REQUIREMENTS OF THE CARPET AND RUG INSTITUTE GREEN LABEL PROGRAM. ALL CARPET ADHESIVE SHALL MEET THE REQUIREMENTS OF TABLE 5.504.4.1. A LETTER FROM THE INSTALLER CERTIFYING COMPLIANCE MUST BE SUBMITTED TO THE BUILDING INSPECTOR. ·AT LEAST 80% OF THE FLOOR AREA RECEIVING RESILIENT FLOORING SHALL MEET ONE OF THE FOLLOWING CRITERIA: [CALGREEN 5.504.4.6]. 8)CERTIFIED UNDER THE RESILIENT FLOOR COVERING INSTITUTE (RFCI) FLOORSCORE PROGRAM. 9)COMPLIANT WITH THE VOC-EMISSION LIMITS AND TESTING REQUIREMENTS SPECIFIED IN THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S 2010 STANDARD METHOD FOR THE TESTING AND EVALUATION CHAMBERS, VERSION 1.1, FEBRUARY 2010. 10)COMPLIANT WITH THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS CALIFORNIA (CA-CHPS) CRITERIA INTERPRETATION FOR EQ 7.0 AND 7.1 DATED JULY 2012 AND LISTED IN THE CHPS HIGH PERFORMANCE PRODUCT DATABASE. 11)PRODUCTS CERTIFIED UNDER UL GREENGUARD GOLD. FIXTURE FLOW RATES: 1)LAVATORY FAUCETS IN RESTROOMS SHALL BE THE SELF-CLOSING TYPE AND SHALL NOT EXCEED A WATER FLOW OF 0.20 GAL/USE. 2)EACH FAUCET SHALL NOT EXCEED A WATER FLOW OF 1.8GPM. 3)WALL MOUNTED URINALS SHALL NO EXCEED 0.125 G.P.F. AND FLOOR MOUNTED URINALS SHALL NOT EXCEED 0.5 G.P.F. 4)TOILETS SHALL BE ULTRA-LOW FLUSH TYPE (1.28 G.P.F. MAX.). 5)EACH SHOWERHEAD SHALL NOT EXCEED A WATER FLOW OF 1.8 GPM 6)WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL THE SHOWERHEADS AND/OR OTHER SHOWER OUTLETS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 1.8 GALLONS PER MINUTE AT 80 PSI, OR THE SHOWER SHALL BE DESIGNED TO ALLOW ONLY ONE SHOWER OUTLET TO BE IN OPERATION AT A TIME. [CAL GREEN SECTION: 5.303.3.3.2]. HVAC, INSULATION, REFRIGERATION, COMMISSIONING: ·THE PERMANENT HVAC SYSTEM SHALL ONLY BE USED DURING CONSTRUCTION IF NECESSARY TO CONDITION THE BUILDING OR AREAS OF ADDITION OR ALTERATION WITHIN THE REQUIRED TEMPERATURE RANGE FOR MATERIAL AND EQUIPMENT INSTALLATION. IF THE HVAC SYSTEM IS USED DURING CONSTRUCTION, RETURN AIR FILTERS WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8, BASED ON ASHRAE 52.2-1999, OR AN AVERAGE EFFICIENCY OF 30% BASED ON ASHRAE 52.1-1992 SHALL BE USED. ALL FILTERS SHALL BE REPLACED IMMEDIATELY PRIOR TO OCCUPANCY OR AT THE CONCLUSION OF CONSTRUCTION. (CAL GREEN SECTION: 5.504.1) ·AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE CONSTRUCTION SITE UNTIL FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF DUST, WATER AND DEBRIS WHICH MAY ENTER THE SYSTEM. (CAL GREEN SECTION: 5.504.3) ·IN MECHANICALLY VENTILATED BUILDINGS, REGULARLY OCCUPIED AREAS OF THE BUILDING SHALL BE PROVIDED WITH AIR FILTRATION MEDIA FOR OUTSIDE AND RETURN AIR THAT PROVIDES AT LEAST A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 13. MERV 13 FILTERS SHALL BE INSTALLED PRIOR TO OCCUPANCY, AND RECOMMENDATIONS FOR MAINTENANCE WITH FILTERS OF THE SAME VALUE SHALL BE INCLUDED IN THE OPERATION AND MAINTENANCE MANUAL. (CAL GREEN SECTION: 5.504.5.3) ·FOR BUILDINGS OR ADDITIONS EQUIPPED WITH DEMAND CONTROL VENTILATION, CO2 SENSORS AND VENTILATION CONTROLS SHALL BE SPECIFIED AND INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF CALIFORNIA ENERGY CODE, SECTION 120.1(C)(4). (CAL GREEN SECTION: 5.506.2) ·WALL AND ROOF-CEILING ASSEMBLIES EXPOSED TO THE NOISE SOURCE MAKING UP THE BUILDING OR ADDITION ENVELOPE OR ALTERED ENVELOPE SHALL MEET A COMPOSITE STC RATING OF AT LEAST 50 OR A COMPOSITE OITC RATING OF NO LESS THAN 40, WITH EXTERIOR WINDOWS OF A MINIMUM STC OF 40 OR OITC OF 30 IF LOCATED WITHIN THE 65 CNEL NOISE CONTOUR OF AN AIRPORT OR WITHIN THE 65 CNEL OR L DN NOISE CONTOUR OF A FREEWAY OR EXPRESSWAY, RAILROAD, INDUSTRIAL SOURCE OR FIXED-GUIDEWAY SOURCE AS DETERMINED BY THE NOISE ELEMENT OF THE GENERAL PLAN. (SECTION 5.507.4.1 CGBSC) ·INSTALLATIONS OF HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT SHALL COMPLY WITH SECTIONS 5.508.1.1 AND 5.508.1.2. HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT SHALL NOT CONTAIN CHLOROFLUOROCARBONS (CFCS) AND SHALL NOT CONTAIN HALONS (SECTION: 5.508.1). ·PROVIDE THE BUILDING OWNER OR REPRESENTATIVE WITH DETAILED OPERATING AND MAINTENANCE INSTRUCTIONS AND COPIES OF GUARANTIES/WARRANTIES FOR EACH SYSTEM. O&M INSTRUCTIONS SHALL BE CONSISTENT WITH OSHA REQUIREMENTS IN CCR, TITLE 8, SECTION 5142, AND OTHER RELATED REGULATIONS. ·DISPOSER SHALL EITHER MODULATE THE USE OF WATER TO NO MORE THAN 1GPM WHEN THE DISPOSER IS NOT IN USE OR SHALL AUTOMATICALLY SHUT OFF AFTER NO MORE THAN 10 MINUTES OF INACTIVITY. DISPOSERS SHALL USE NO MORE THAN 8 GPM OF WATER. ·INSTALLED FILTERS SHALL BE CLEARLY LABELED BY THE MANUFACTURER INDICATING THE MERV RATING. ·A COMPLETE REPORT OF COMMISSIONING PROCESS ACTIVITIES UNDERTAKEN THROUGH THE DESIGN, CONSTRUCTION, AND REPORTING RECOMMENDATIONS FOR POST-CONSTRUCTION PHASES OF THE BUILDING PROJECT SHALL BE COMPLETED AND PROVIDED TO THE OWNER OR REPRESENTATIVE. IRRIGATION: ·IRRIGATION SYSTEMS SHALL BE DESIGNED AND MAINTAINED TO PREVENT SPRAY ON STRUCTURES. [CALGREEN 5.407.2.1] ·FIXTURES, FURNITURE AND EQUIPMENT ·INTERIOR PARTITIONS AND DOORS ·CEILING IN ALL AREAS ·FINISHES IN ALL AREAS ·LIGHTING IN ALL AREAS ·RESTROOM(S) INCLUDING PLUMBING FIXTURES ·DRINKING FOUNTAIN(S) AND WATER HEATER SCOPE OF WORK G000 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/25/23 07/24/23 BUILDING COMMENTS COVER SHEET NO. ITEM FURNISHED INSTALLED DEMOLITION REMARKS 1.00 STOREFRONT LL PS GC LL PS GC REMOVE TO REMAIN RELOCATE REPLACE EXISTING SPECIAL ACTION 1.01 STOREFRONT SYSTEM X X X X 1.02 STOREFRONT SYSTEM OVERLAY METAL/BELBIEN X X X X 1.03 1" TEMPERED STOREFRONT GLASS X X X X CLEAN TO "LIKE NEW" CONDITION 1.04 ALUM/GLASS ENTRY DOORS X X X X ROLLING GRILLE CLEAN TO "LIKE NEW" CONDITION 1.05 ENTRY DOOR HARDWARE LOCKS X X X X 1.06 EXTERIOR STOREFRONT BLOCKING X X X X 1.07 STOREFRONT WOOD/EXTERIOR ALTERNATE X X X X SEE PLANS AND ELEVATIONS 1.08 SUITE NUMBERS X X X X WHEN REQUIRED 1.09 BLADE SIGN BRACKET X X X X COORDINATE INSTALL WITH SIGNAGE CONTRACTOR 1.10 KNOX BOX X X X X WHEN REQUIRED 1.11 ELECTRICAL FOR STOREFRONT SIGN X X X X COORDINATE INSTALL WITH SIGNAGE CONTRACTOR 1.12 STOREFRONT SIGN X X X X COORDINATE INSTALL WITH SIGNAGE CONTRACTOR 1.13 BACKING FOR STOREFRONT SIGN X X X X 1.14 BLADE SIGN X X X X INSTALLED BY SIGN VENDOR 2.00 FLOORING/BASE/TRIM LL PS GC LL PS GC REMOVE TO REMAIN RELOCATE REPLACE EXISTING SPECIAL ACTION 2.01 FLOOR DEMO,SCRAPE,PREP.X X PREPARE EXISTING SLAB FOR NEW FINISHES (SEE PLANS) 2.02 TRANSITION STRIPS X X X 2.03 RUBBER BASE (NON-SALES)X X X 2.04 4" WOOD BASE PAINTED AND CLEAR COAT (SALES AREA)X X 2.05 4" MAPLE BASE AND TRIM IN FITTING ROOMS AND ALCOVE ONLY X X 2.06 POLISHED CONCRETE FLOOR X X E.C. TO PROVIDE TEMP POWER AS REQUIRED 2.07 TOILET ROOM FLOORING AND BASE X X X 2.08 PATCHING CONCRETE X X CONCRETE ONLY; ALTERNATE TO BE APPROVED BY CM 2.09 FLOOR PROTECTION X X 2.10 GRIND AND SEALED CONCRETE (NON-SALES)X X 3.00 WALLS LL PS GC LL PS GC REMOVE TO REMAIN RELOCATE REPLACE EXISTING SPECIAL ACTION 3.01 DEMISING WALL GYP. BD.X X X X PATCH/REPAIR AS REQUIRED PER UL 465 3.02 DEMISING WALL STUDS X X X X 3.03 SALES WALLS FRAMING/BLOCKING/GYP. BD.X X X X 3.04 TOILET ROOM FRAMING/BLOCKING/GYP. BD.X X 3.05 FITTING ROOM FRAMING/BLOCKING/GYP. BD.X X 3.06 INTERIOR PARTITIONS X X X X 3.07 WALL PREPREATION AND PAINT X X 3.08 SURFACE MOUNTED AND CONCEALED BLOCKING X X 3.09 PAINT AND TOUCH-UP PAINT X X PRIOR TO PUNCH, TURNOVER AND OPENING - AFTER HOURS FOR LAST TOUCH UP 3.10 FRP WAINSCOTT WALL PANELS X X GP-1 3.11 CORNER GUARDS - STAINLESS STEEL (NON SALES)X X 3.12 CORNER GUARDS - CLEAR (SALES AREA)X X 3.13 SOUND ATTENUATING INSULATION X X 3.14 COLUMN PAINT X X 3.15 PARTIAL HEIGHT WALL X X 4.00 CEILING LL PS GC LL PS GC REMOVE TO REMAIN RELOCATE REPLACE EXISTING SPECIAL ACTION 4.01 GYP. BD. CEILINGS OR SOFFITS X X X X 4.02 BOH CEILING X X X X 4.03 FITTING ROOM CEILING X X X X 4.04 FRAMING/GYP. BD./PLYWOOD AT TOILET ROOM X X X X 4.05 TOILET & STORAGE ROOM CEILING X X X X P-8 ABOVE SALES AREA AND FITTING ROOMS 4.06 BANNER TRACKS X X X X 2 ROWS-SECURED AT 12" AND 24". SECURE TO METAL STUD 5.00 DOORS LL PS GC LL PS GC REMOVE TO REMAIN RELOCATE REPLACE EXISTING SPECIAL ACTION 5.01 STOCK ROOM DOOR/FRAME/HARDWARE X X 5.02 FITTING ROOM DOORS/FRAMES/HARDWARE X X Leversets provided by PS 5.03 TOILET ROOM DOOR/FRAME/HARDWARE X X 5.04 REAR DOOR AND FRAME X X 5.05 REAR DOOR HARDWARE X X 5.06 REAR DOOR PANIC BAR/7 PIN RIM CYLINDER X X 5.07 TOILET ROOM DOOR/FRAME X X 5.08 STORAGE ROOM DOOR/FRAME X X 5.09 ACCESS PANELS AS REQ'D FOR MOTORS/VAV/AV/ETC.X X AS REQUIRED 5.10 KICK PLATES X X 5.11 DOOR STOPS X X 6.00 LIGHTING LL PS GC LL PS GC REMOVE TO REMAIN RELOCATE REPLACE EXISTING SPECIAL ACTION 6.01 SALES AREA TRACK AND LIGHTS X X X X 6.02 BOH LIGHTS X X X X 6.03 TOILET ROOM & STORAGE ROOM X X X X 6.04 DECORATIVE LIGHTING X X X X 6.05 EXIT/EMERGENCY LIGHTS X X X X 6.06 AUTOMATIC LIGHTING SENSORS X X X X 6.07 FITTING ROOM DIMMER SWITCHES X X X X 6.08 FITTING ROOM & ALCOVE LIGHTS X X X X 6.09 EXTERIOR STOREFRONT LIGHTS X X X X 7.00 FIXTURES / SALES AREA LL PS GC LL PS GC REMOVE TO REMAIN RELOCATE REPLACE EXISTING SPECIAL ACTION 7.01 CASH WRAP & BACKWRAP X X 7.02 FLOOR FIXTURES X X TENANT G.C. TO COUNT IN, ASSEMBLE AND SET IN PLACE PER TENANT FIXTURE PLAN 7.03 WALL STANDARDS AND/OR OUTRIGGERS X X 7.04 WALL & COLUMN MIRRORS X X 7.05 MERCHANDISING HARDWARE X X TENANT G.C. TO COUNT IN HARDWARE 8.00 STOCK ROOM LL PS GC LL PS GC REMOVE TO REMAIN RELOCATE REPLACE EXISTING SPECIAL ACTION 8.01 MANAGER'S DESK X X TENANT G.C. TO ASSEMBLE 8.01 PROCESSING DESK X X TENANT G.C. TO ASSEMBLE 8.02 SHIPPING AND RECEIVING DESK (WHITE MELAMINE/METAL LEGS)X X TENANT G.C. TO PURCHASE & INSTALL 8.03 MOP SINK X X 8.04 WATER COOLER X X 8.05 FILE CABINET X X 8.06 PEG BOARD X X TENANT G.C. TO INSTALL ON THE SIDES OF EACH ROLLING BAY, ABOVE THE BRAKE TO T.O. RACK 8.07 SAFE X X 8.08 LOCKERS X X TENANT G.C. TO ATTACHE TO THE WALL 8.09 PLYWOOD STRAPPING/BACKING FOR STANDARDS X X 8.10 STANDARDS & BRACKETS X X 8.11 SHELVING ABOVE DESKS X X FIRE TREATED IF REQUIRED 8.12 BULLETIN BOARDS X X VERIFY LOC. WITH PACSUN OPERATIONS (4) AT TURNOVER 8.13 PRIMER & PAINTING X X 8.14 PERIMETER SHELVING, BRACKETS AND CLIPS X X 8.15 ROLLING SHELVING UNITS AND BRAKES X X TENANT G.C. TO LEVEL FLOOR PRIOR TO INSTALLING 8.16 LADDER HOOKS X X 8.17 PLAN AND PUNCH TUBES X X (2) SETS 8.18 C OF O FRAME X X 8.19 REFRIGERATOR/MICROWAVE X X 8.20 PLYWOOD BACKING FOR DSL X X 9.00 MISCELLANEOUS LL PS GC LL PS GC REMOVE TO REMAIN RELOCATE REPLACE EXISTING SPECIAL ACTION 9.01 PICK-UP PERMIT/PAY PERMIT FEES X X 9.02 OBTAIN ALL APPLICABLE PERMITS & CERTIFICATE OF OCCUPANY X X 9.03 TEMPORARY UTILITY FEES X X 9.04 UTILITY SERVICE(S) AND METER(S)X X 9.05 ALL HAZARDOUS MATERIALS REPORTS (IF REQUIRED)X X 9.06 LOW VOLTAGE PLANS/PERMIT/ FEES X X 9.07 MOBILE SHELVING (NON SALES) PLANS/PERMIT/ FEES X X 9.08 SIGNAGE PLANS/PERMIT/ FEES X X 9.09 SPECIAL INSPECTIONS/ADA PLANS/PERMIT/ FEES X X 9.10 FIRE ALARM PLANS/PERMIT/ FEES X X 9.11 SPRINKLER SYS. PLANS/PERMIT/ FEES X X VERIFY MALL'S REQUIRED CONTRACTOR 9.12 DEMOLITION/PERMIT AND FEE'S AS REQUIRED X X 9.13 MALL DEPOSIT/ INSURANCE WAIVERS X X 9.14 JANITORIAL SERVICE/FINAL CLEANING X X MIN (3) FULL CLEANINGS - AFTER HOURS FOR THE LAST CLEANING 9.15 TRASH REMOVAL/DUMPSTER RENTAL X X 9.16 ROOF PENETRATIONS X X VERIFY MALL'S REQUIRED CONTRACTOR 9.17 TEMPORARY BARRICADE X X COORDINATE WITH MALL MANAGEMENT 9.18 BARRICADE GRAPHICS X X 9.19 CASP ADA INSPECTIONS X X 9.20 TITLE 24 X X 10.00 SPECIALTY LL PS GC LL PS GC REMOVE TO REMAIN RELOCATE REPLACE EXISTING SPECIAL ACTION 10.01 COMPUTER / POS SYSTEM X X X X 10.02 BUZZER SYSTEMS X X At cashwrap & BOH 10.03 FIRE EXTINGUISHERS X X VERIFY LOCATIONS W/ FIRE MARSHALL 10.04 FIRE ALARM X X WHEN REQUIRED - SEE ELEC DRAWINGS 10.05 TRAFFIC COUNTER PULL STRING X X 10.06 TRAFFIC COUNTER INSTALLATION X X 10.07 CASH WRAP SIGNAGE X X what is this? 10.08 CASH WRAP PIN PAD BRACKETS X X 10.09 NEUTRAL PIERS X X X X 10.10 MALL FLOORING X X X X 10.11 REVEALS X X X 10.12 TAKE BEFORE AND AFTER PHOTOS OF ALL CONSTRUCTION X X PHOTOS TO BE SUBMITTED VIA POWERPOINT EVERY FRIDAY FROM START TO OPENING 11.00 FITTING ROOMS LL PS GC LL PS GC REMOVE TO REMAIN RELOCATE REPLACE EXISTING SPECIAL ACTION 11.01 FITTING ROOM BASE & TRIM X X X X 11.02 MIRRORS X X X X 11.03 MIRROR J-CHANNEL X X X X 11.04 HOOKS ON WALLS X X X X GC TO PROVIDE BACKING 11.05 CAULKS/SILICONES/MASTICS/ADHESIVES X X X X AS REQUIRED 11.06 ADA BENCH X X X X H.C. FITTING ROOM ONLY, TENANT GC TO SECURE TO THE WALL 11.07 CODE RELATED SIGNAGE X X X X AS REQUIRED 11.08 FITTING ROOM SIGNAGE X X X X PER PLAN LOCATIONS 11.09 ANTI GRAFFITI FILM X X X X ALL MIRRORS 12.00 AUDIO & VIDEO LL PS GC LL PS GC REMOVE TO REMAIN RELOCATE REPLACE EXISTING SPECIAL ACTION 12.01 MUSIC SYSTEM SPEAKERS, WIRE, INSTALLATION X X X X 12.02 MUSIC SYSTEM EQUIPMENT X X X X 12.03 PULL STRING, CONDUIT AND BOXES FOR AUDIO & VIDEO X X X X 12.04 PLYWOOD BACKING X X X X 12.05 VIDEO DISPLAY & SYSTEM X X X X 13.00 TOILET ROOM LL PS GC LL PS GC REMOVE TO REMAIN RELOCATE REPLACE EXISTING SPECIAL ACTION 13.01 PLUMBING FIXTURES X X X X Re-use where possible 13.02 SIGNAGE X X X X 13.03 MIRROR X X X X 13.04 HOT WATER HEATER X X X X 13.05 WASTE RECEPTOR X X X X 14.00 STORAGE ROOM LL PS GC LL PS GC REMOVE TO REMAIN RELOCATE REPLACE EXISTING SPECIAL ACTION 14.01 WALLS AND DOOR X X X X 14.02 DOOR HARDWARE X X X X 14.03 FLOORING X X X X 15.00 SYSTEMS LL PS GC LL PS GC REMOVE TO REMAIN RELOCATE REPLACE EXISTING SPECIAL ACTION 15.01 HVAC SYSTEM DISTRIBUTION X X 15.02 HVAC SYSTEM UNIT/TSTAT X X 15.03 ELECTIRCAL (WIRING AND OUTLETS)X X X 15.04 ELECTRICAL TRANSFORMER X X X 15.05 ELECTRICAL SYSTEM- MAIN PANEL X X X 15.06 ELECTRICAL SYSTEM - SUB PANEL X X X X 15.07 LIGHTING SYSTEM X X X X 15.08 LIGHTING INVERTER, LCP, TVSS, SWITCHES, SENSORS, DIMMERS X X X X 15.09 LOW VOLTAGE WIRING X X 15.10 LOW VOLTAGE CONDUIT X X 15.11 FIRE ALARM SYSTEM X X X X WHEN REQUIRED - SEE ELEC DRAWINGS 15.12 FIRE ALARM DEVICES/CONNECTION TO PANEL X X X X 15.13 FIRE ALARM PANEL X X X X 15.14 PLUMBING MAIN SERVICE X X X X 15.15 PLUMBING (BRANCH LINES,NEW AND OR MODIFICATIONS X X X X 15.16 SPRINKLER BRANCH LINES AND HEADS X X X X 15.17 SPRINKLER MAINS X X X X X 15.18 TELEPHONE/INTERNET SERVICE TO BUILDING X X X X 15.19 TELE/DATA BACKER BOARD X X X X PROJECT DESCRIPTION TENANT IMPROVEMENT MERCHANDISE RETAIL SALE PROJECT LOCATION NEWPORT CENTER DRIVE & SANTA MARIA ROAD 400 SOUTH BALDWIN AVEANUE LEVEL 2, SPACE #: H12, H13 AND H14 ARCADIA, CALIFORNIA 91007 GOVERNING CODES ALL WORK SHALL BE IN CONFORMANCE WITH, BUT NOT LIMITED TO, ANY STATE AND LOCAL CODES HAVING JURISDICTION AS WELL AS THE REQUIREMENTS OF THE FOLLOWING: BUILDING 2022 CALIFORNIA BUILDING CODE MECHANICAL 2022 CALIFORNIA MECHANICAL CODE ELECTRICAL 2022 CALIFORNIA ELECTRIC CODE PLUMBING 2022 CALIFORNIA PLUMBING CODE FIRE 2022 CALIFORNIA FIRE CODE ENERGY 2022 CALIFORNIA ENERGY CODE T-24 ENERGY STANDARDS GREEN BUILDING 2022 CALIFORNIA GREEN BUILDING CODE ACCESSIBILITY 2022 CBC - TITEL 24, PART 2 PROJECT INFORMATION CONSTRUCTION TYPE II-B FULLY SPRINKLERED OCCUPANCY GROUP M - MERCANTILE (3) STORY BUILDING GROSS LEASED PREMISES 5,294 SQ. FT. OCCUPANT LOAD ROOM NAME SQ. FT.LOAD FACTOR OCCUPANT LOAD SALES AREA 3417 ÷ 60 57 FITTING ROOM 411 ÷ 60 7 HALLWAY 156 ÷ 60 3 STOCK ROOM (S1)825 ÷ 300 3 TOILET ROOM 1 64 ÷ 60 2 TOILET ROOM 2 64 ÷ 60 2 TOTAL NUMBER OF OCCUPANTS 74 EXIT REQUIREMENTS TWO EXITS REQUIRED WHEN OCCUPANT LOAD IS GREATER THAN 49 OR COMMON PATH OF TRAVEL EXCEEDS 75FT REQUIRED PROVIDED TOTAL NUMBER OF EXITS 2 2 MAXIMUM TRAVEL DISTANCE:114'-0"<200' FOR EXIT PATH OF TRAVEL SEE EGRESS PLAN ON SHEET G101. PLUMBING FIXTURE REQUIREMENTS DISTANCE TO PUBLIC TOILET ROOMS: FIXTURE LOAD FACTOR REQUIRED PROVIDED MALE FEMALE WATER CLOSET 1 PER 1-100 1 PER 1-100 2 2 LAVATORY 1 PER 1-200 1 PER 1-200 2 2 SEPARATE FACILITIES --YES YES DRINKING FOUNTAIN 1000 1 1 SERVICE SINK --- MOP SINK --- SEPARATE FACILITIES SHALL NOT BE REQUIRED IN MERCANTILE OCCUPANCIES IN WHICH THE MAXIMUM OCCUPANT LOAD IS 50 OR LESS EXIT ILLUMINATION EMERGENCY EXIT ILLUMINATION SHALL BE PROVIDED AS SHOWN ON ELECTRICAL SHEET. MUNICIPAL REVIEW CITY OF ARCADIA COMMERCIAL BUILDING PERMIT 240 WEST HUNTINGTON DRIVE P.O. BOX: 60021 FIRST LEVEL ARCADIA, CALIFORNIA 91066 (626) 574-5423 1.ALL WORK AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH ALL CODES HAVING JURISDICTION. 2.ALL WORK SHALL BE PERFORMED IN CONFORMANCE WITH THE BUILDING MANAGEMENT'S RULES AND REGULATIONS. 3.MODIFICATIONS TO THE BASE BUILDING STRUCTURE, CORE AREAS, AND UTILITY SYSTEMS ARE NOT IN THIS CONTRACT, EXCEPT AS NOTED ON THESE DRAWINGS OR AS REQUIRED TO COMPLETE THE WORK INDICATED ON THESE DRAWINGS. 4.THE G.C. SHALL MAKE ALL ARRANGEMENTS AND PAY FOR ALL FEES AND PERMITS REQUIRED, AS WELL AS ANY ADDITIONAL CHARGES FOR HAULING, RIGGING, AND TRANSPORTATION CHARGES. 5.THE CONTRACT DOCUMENTS CONSIST OF THE AGREEMENT BETWEEN PACSUN AND G.C. (HEREINAFTER REFERRED TO AS THE AGREEMENT) WITH CONDITIONS OF THE CONTRACT (GENERAL, SUPPLEMENTARY, AND OTHER CONDITIONS), DRAWINGS, SPECIFICATIONS, ADDENDA ISSUED PRIOR TO THE EXECUTION OF THE AGREEMENT, OTHER DOCUMENTS LISTED IN THE AGREEMENT, AND MODIFICATIONS ISSUED AFTER EXECUTION OF THE AGREEMENT. 6.THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL ITEMS NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK BY THE CONTRACTORS. PERFORMANCE BY THE G.C. SHALL BE REQUIRED ONLY TO EXTENT CONSISTENT WITH THE CONTRACT DOCUMENTS AND REASONABLY INFERABLE FROM THEM AS BEING NECESSARY TO PRODUCE THE INTENDED RESULTS. 7.THE CONTRACT DOCUMENTS SHALL NOT BE CONSTRUED TO CREATE A CONTRACTUAL RELATIONSHIP OF ANY KIND (1) BETWEEN THE ARCHITECT AND G.C., (2) BETWEEN PACSUN AND A SUBCONTRACTOR OR SUB-SUBCONTRACTOR, OR (3) BETWEEN ANY PERSONS OR ENTITIES OTHER THAN PACSUN AND G.C. 8.EXECUTION OF THE CONTRACT BY G.C. IS A REPRESENTATION THAT THE G.C. HAS VISITED THE SITE AND HAS BECOME FAMILIAR WITH THE LOCAL CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING WORK AND SHALL NOTIFY ARCHITECT AND/OR ENGINEER IF A CONDITION EXISTS WHICH PREVENTS THE CONTRACTOR FROM ACCOMPLISHING THE INTENT OF THE DRAWINGS. 9.THE TERM "WORK" MEANS THE CONSTRUCTION AND SERVICES REQUIRED BY THE CONTRACT DOCUMENTS, WHETHER COMPLETED OR PARTIALLY COMPLETED, INCLUDES ALL LABOR, MATERIALS, EQUIPMENT, AND SERVICES PROVIDED (OR TO BE PROVIDED) BY THE G.C. TO FULFILL THE G.C.'S OBLIGATIONS. THE WORK MAY CONSTITUTE THE WHOLE OR PART OF THE PROJECT. 10.G.C. SHALL NOT CUT OR DISTURB EXISTING STRUCTURAL SYSTEM. THE G.C. SHALL X-RAY/PACHOMETER SLAB TO DETERMINE IF POST TENSIONED SLAB OR IF DESIGN IS IN CONFLICT WITH EXISTING STRUCTURAL SYSTEMS WHEN THE FOLLOWING OCCURS: 10.1.TENANT SPACE IS LOCATED ON SECOND FLOOR OR ABOVE 10.2.LOWER LEVEL EXTENDS BELOW THE TENANT SPACE 10.3.ABSENCE OF STRUCTURAL DRAWINGS FROM ARCHITECTS AND/OR LANDLORD 10.4.ABSENCE OF STRUCTURAL DRAWINGS INCLUDED WITH CONTRACT DOCUMENTS 11.G.C. SHALL ONLY INCLUDE AN ALLOWANCE IN HIS BID FOR THE X-RAY/PACHOMETER WHEN ANY OR ALL OF THE ABOVE OCCUR, TYP. 12.PROVIDE CONTROL KEY AND MASTER KEY AS REQUIRED BY CONTRACT. PERFORM ALL REQUIRED CLEANINGS AS PER CONTRACT INCLUDING, BUT NOT LIMITED TO, ALL STOREFRONT WINDOWS, MULLIONS, CEILINGS, SUPPLY/RETURN AIR GRILLS, FLOORING AND FLOOR WAX, TOILET ROOMS, TOILET ROOM CAULKING, AND WALK-OFF MAT. REMOVE ALL TRASH AND DEBRIS FROM THE SITE. 13.ALL REFERENCES HEREAFTER TO CONSTRUCTION PM OR ARCHITECT REFER TO THE CONTACT LISTED IN PROJECT TEAM. 14.PROVIDE OCCUPANCY SIGNS CONFORMING TO APPLICABLE BUILDING CODE REQUIREMENTS. 15.PROVIDE ADDITIONAL EXIT SIGNS AND FIRE EXTINGUISHERS IN TYPE, NUMBER, AND LOCATION AS DIRECTED BY THE FIRE DEPARTMENT FIELD INSPECTOR. GENERAL NOTES SHEET SYMBOLS PROJECT TEAM X# X### X### X1 X### X1 X2 X3 X### X1 X2 X### X1 X2 X3 X4 ### X# X### SECTION NUMBER SHEET NUMBER DETAIL NUMBER SHEET NUMBER CODE ANALYSIS X# X### EXTERIOR ELEVATION INDICATOR X#TITLE 1" = 1" (FULL) SECTION DETAIL INTERIOR ELEVATION INDICATOR ELEVATION NUMBER SHEET NUMBER DRAWING TITLE DRAWING NUMBER DRAWING INDICATOR SCALE REVISION CLOUD KEYED NOTES REVISION NUMBER ELEVATION NUMBER SHEET NUMBER X# X### ABBREVIATIONS ACP.ACOUSTICAL CEILING ADJ.ADJACENT AL.,ALUM.ALUMINUM ALT.ALTERNATE A.P.ACCESS PANEL APPX.APPROXIMATE ARCH.ARCHITECTURAL BD.BOARD BLDG.BUILDING BLK.BLOCK BLKG.BLOCKING BM.BEAM BOT.BOTTOM CAB.CABINET CEM.CEMENT CKT.CIRCUIT CLG.CEILING CLR.CLEAR CMU.CONCRETE MASONRY UNIT COL.COLUMN CONC.CONCRETE CONST.CONSTRUCTION CONT.CONTINUOUS CPT.CARPET CTR.CENTER DET.DETAIL DIA.DIAMETER DIFF.DIFFUSER DIM.DIMENSION DWG(S).DRAWING, DRAWINGS DEMO.DEMOLITION (E)EXISTING EA.EACH E.I.F.S.EXTERIOR INSULATION FINISH SYSTEM ELEC.ELECTRIC, ELECTRICAL EM.EMERGENCY EQ.EQUAL EQUIP.EQUIPMENT EWC.ELECTRIC WATER COOLER EXH.EXHAUST EX.EXISTING EXTIR.EXTINGUISHER FIN.FINISH FIXT.FIXTURE FLR.FLOOR F.R. FIRE RATED/RETARDANT F.R.P. FIBERGLASS REINFORCED POLYESTER PANEL F.R.T.FIRE RETARDANT TREATED GA. GAUGE GALV.GALVANIZED GND,GRND GROUND GYP. GYPSUM H.M. HOLLOW METAL HR. HOUR HT.HEIGHT H.V.A.C. HEATING, VENTILATING, AIR CONDITIONING J.H.A. JURISDICTION HAVING AUTHORITY LAM.LAMINATE LAV.LAVATORY LL.LANDLORD LT.LIGHT L.V.T.LUXURY VINYL TILE MAX.MAXIMUM MECH.MECHANICAL MTL.METAL MFR.MANUFACTURER MIN.MINIMUM MIR.MIRROR MISC.MISCELLANEOUS MTD. MOUNTED MTG.MOUNTING N.I.C.NOT IN CONTRACT NOM.NOMINAL N.T.S.NOT TO SCALE O.C.ON CENTER O.D.OUTSIDE DIAMETER OPP.OPPOSITE PLYWD.PLYWOOD PNL.PANEL PROP.PROPERTY P.T.PRESSURE TREATED PWR.POWER QTY.QUANTITY R.RADIUS REQ.REQUIRED R.O.ROUGH OPENING S.C.SOLID CORE SCHED.SCHEDULE SECT.SECTION SQ.FT.SQUARE FEET SIM.SIMILAR SPEC.SPECIFICATION SQ.SQUARE STD.STANDARD STL.STEEL STRUCT.STRUCTURAL SYM.SYMMETRICAL TBD TO BE DETERMINED TEL.TELEPHONE TELCO.TELE-COMMUNICATIONS TYP.TYPICAL PAC.PACSUN U.O.N.UNLESS OTHERWISE NOTED VCT.VINYL COMPOSITION W/WITH WD.WOOD W/O WITHOUT WP.WATERPROOF W.R.WATER RESISTANT WT.WEIGHT CONTACT: PHONE: EMAIL: LANDLORD THE SHOPS AT SANTA ANITA DONNA T. GUERRERO (626) 632 - 0781 DONNA@SHOPSATSANTAANITA.COM CONTACT: PHONE: EMAIL: ARCHITECTURE SARGENTI ARCHITECTS JELENA NIKOLIC (480) 448 - 6250 JNIKOLIC@SARGARCH.COM CONTACT: PHONE: EMAIL: ENGINEERING ARDEBILI ENGINEERING, LLC HICHAM KHACHANE (480) 626 - 7072 HICHAM@ARDEBILIENG.COM Section 3.6. Pursuant to Section 1938 of the California Civil Code, Landlord hereby advises Tenant that the Premises, as delivered to Tenant, has not undergone an inspection by a Certified Access Specialist (CASp). Landlord makes no representations or warranties with respect to the Premises complying with any applicable federal, state and local standards, codes, rules and regulations governing physical access for persons with disabilities at places of public accommodation, including, but not limited to, the Americans with Disabilities Act of 1990, California's Unruh Civil Rights Act, California Building Standards Code, or California Health and Safety Code (collectively, the "Accessibility Laws"). Section 1938 of the California Civil Code, as amended, also requires the following statement: "A Certified Access Specialist (CASp) can inspect the subject premises and determine whether the subject premises comply with all of the applicable construction-related accessibility standards under state law. Although state law does not require a CASp inspection of the subject premises, the commercial property owner or lessor may not prohibit the lessee or tenant from obtaining a CASp inspection of the subject premises for the occupancy or potential occupancy of the lessee or tenant, if requested by the lessee or tenant. The parties shall mutually agree on the arrangements for the time and manner of the CASp inspection, the payment of the fee for the CASp inspection, and the cost of making any repairs necessary to correct violations of construction-related accessibility standards within the premises." If Tenant requests a CASp inspection of the Premises pursuant to this Section, Tenant shall be solely responsible for all fees or costs associated with the CASp inspection. To the extent Tenant's CASp inspection indicates the Premises does not meet all of the Accessibility Laws, Landlord and Tenant mutually agree that Tenant shall immediately make any repairs or modifications necessary to bring the Premises into compliance with the Accessibility Laws at Tenant's sole cost and expense. CALIFORNIA ACCESSIBILITY DISCLOSURE RESPONSIBILITY SCHEDULE DEFERRED SUBMITTALS SIGNAGE SEPARATE SUBMITTAL BY VENDOR STORAGE RACK SHOP DRAWINGS SEPARATE SUBMITTAL BY VENDOR FIRE SPRINKLER SYSTEM SEPARATE SUBMITTAL BY G.C. FIRE ALARM MODIFICAITON SEPARATE SUBMITTAL BY G.C. NOTE: ARCHITECT TO COORDINATE DEFERRED SUBMITTALS WITH ARCHITECTURAL DRAWINGS AND CERTIFY DEFERRED SUBMITTALS PRIOR SUBMITTING TO PERMIT. DRAWING INDEX ARCHITECTURAL G000 COVER SHEET G001 ARCHITECTURAL DATA SHEET G002 ACCESSIBILITY DETAILS (CAL) G003 CALIGREEN REQUIREMENTS G004 CALIGREEN REQUIREMENTS G005 CALIGREEN REQUIREMENTS G101 KEY PLAN, VICINITY MAP, AND EGRESS PLAN A100 BARRICADE PLAN, ELEVATIONS AND SECTION A101 DEMOLITION FLOOR PLAN A102 DEMOLITION REFLECTED CEILING PLAN A103 DEMOLITION ENLARGED STOREFRONT PLAN AND ELEVATIONS A110 SITE PLAN A111 CONSTRUCTION FLOOR PLAN A121 FINISH FLOOR PLAN A131 REFLECTED CEILING PLAN A141 FIXTURE PLAN A201 INTERIOR ELEVATIONS A202 INTERIOR ELEVATIONS A300 STOREFRONT PLAN AND ELEVATIONS A301 STOREFRONT SECTIONS AND DETAILS A302 STOREFRONT SECTIONS AND DETAILS A303 STOREFRONT DETAILS A401 ENLARGED UNISEX TOILET ROOM A402 ENLARGED HALLWAY & STOCKROOM A501 PARTITION DETAILS A502 SALES AND STOCK ROOM SECTIONS AND DETAILS A503 SECTIONS AND DETAILS A504 CEILING DETAILS A505 FLOORING AND BASE DETAILS A611 DOOR SCHEDULE A700 SCHEDULES A701 SCHEDULES MECHANICAL M0.1 MECHANICAL SCHEDULES, PLANS AND DETAILS M1.0 MECHANICAL SPECIFICATIONS ELECTRICAL E0.1 ELECTRICAL SPECIFICATIONS & SYMBOLS E0.2 ELECTRICAL INTERIOR LIGHTING T-24 E0.3 ELECTRICAL LIGHTING CONTROL DEVICE CUT SHEETS E1.0 LIGHTING FLOOR PLAN E1.1 EMERGANCY LIGHTING PHOTOMETRIC PLAN E2.0 POWER FLOOR PLAN E3.0 ONE-LINE DIAGRAM PLUMBING P0.1 PLUMBING SCHEDULES P0.2 PLUMBING TITLE-24 COMPLIANCE P1.0 PLUMBING FLOOR PLANS P2.0 PLUMBING SPECIFICATIONS STRUCTURAL S1.1 G.S.N. S2.1 FLOOR AND CEILING FRAMING PLAN S3.1 DETAILS CONTACT: PHONE: EMAIL: STRUCTURAL CTS STRUCTURAL ENGINEERS DAVID TROXELL, SE, PE (480) 774 - 1762 DTroxell@CTSAZ.COM CONTACT: PHONE: EMAIL: MANAGEMENT GEAR MANAGEMENT JORDAN LEMOS-SCHABELY (623) 734 - 6307 JLEMOS-SCHABELY@GEARMG.COM CONTACT: PHONE: EMAIL: CLIENT PACSUN ERNIE SIBAL (714) 414 - 4303 ESIBLE@PASIFICSUNWEAR.COM 2 3 S1 3 G001 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/25/23 07/24/23 BUILDING COMMENTS ARCHITECTURAL DATA SHEET TOP OF FLOORING TOP OF COUNTER TO BE @ +34" A.F.F. MAX. 6X6 INTERNATIONAL SIGN OF ACCESSIBILITY AT CORNER OF SALES COUNTER B ADA COUNTER ELEVATION ACCESSIBLE RESTROOM SIGNAGE 1/4" = 1'-0" UNISEX 12 " D I A . UNISEX TRIANGLE 1/4" THICK SUPERIMPOSED ON 12" DIA. CIRCLE 3B 58 " M I N . - 6 0 " M A X . TO C E N T E R O F S Y M B O L 9" 5' - 0 " M A X T O T O P 48 " M I N T O B O T T O M A ELEVATION VIEW B UNISEX RESTROOM PLAQUE EQ.EQ. TEXT G002 B - B - AREA OF PICTOGRAM UNISEX RESTROOM NOTE: 1. ACCESSIBILITY SIGNAGE: PROVIDE ACRYLIC REVERSE SILK SCREENED SIGNS WITH INTERNATIONAL SYMBOL OF ACCESSIBILITY, RAISED LETTERS, AND BRAILLE, AT ACCESSIBLE TOILET FACILITIES; ONE FOR EACH SEX OR ONE UNISEX. 2. LETTERS AND NUMBERS ON SIGNS SHALL BE RAISED CONTRASTING IN COLOR, AND HAVE A WIDTH-TO-HEIGHT RATIO OF BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH-TO-HEIGHT RATIO BETWEEN 1:5 AND 1:10, AND RAISED 1/32" MIN. AND BE ACCOMPANIED BY BRAILLE RAISED LETTERING. 3. WHERE PERMANENT SIGNAGE IS PROVIDED FOR ROOMS AND SPACES, SIGNAGE AS DESCRIBED ABOVE SHALL BE PROVIDED ON THE STRIKE SIDE OF THE DOOR. 4. SEE SPECIFICATIONS FOR SIGNAGE & MOUNTING. 5. REFER TO ACCESSIBLE SIGNAGE TABLE ON SHEET A401 4 TACTILE EXIT SIGNAGE DETAILS 1/4" = 1'-0" B - 60 " M A X . F R O M T H E B A S E L I N E O F TH E H I G H E S T L I N E O F R A I S E D 9" MIN. 34 " M I N . 44 " M A X WALL MOUNTED TACTILE SIGNAGE A TACTILE EXIT SIGNAGE (PLASTIC SIGN)B EXIT SIGN DETAIL SIGN BACKGROUND COLOR: PMS262C. REFER TO SPEC FOR ADDITIONAL INFORMATION. LETTERS AND NUMBERS SHALL BE UPPER CASE, SANS SERIF TYPE COLOR: WHITE CORRESPONDING GRADE 2 BRAILLE REFER TO TACTILE NOTES (THIS DETAIL) FOR ADDITIONAL INFORMATION. LETTERS AND NUMBERS SHALL BE AT LEAST 5/8" HIGH, BUT NO HIGHER THAN 2" LETTERING RAISED 1/32" EXIT EXIT NOTE: 1. TACTILE SIGNAGE SHALL BE ALLOWED ON THE PUSH SIDE OF A DOOR WHEN THE FOLLOWING CONDITIONS EXIST: DOOR HAS A CLOSER, DOOR DOES NOT HAVE A HOLD OPEN DEVICE THAT PREVENTS IT FROM CLOSING. 2. REFER TO ACCESSIBLE SIGNAGE TABLE ON SHEET A401 48 " M I N . F R O M T H E B A S E L I N E O F TH E L O W E S T B R A I L L E C E L L S 18" MIN. 18 " M I N . C LOCATION OF TACTILE SIGNS AT DOORS CENTERED ON TACTILE CHARACTERS 3 TACTILE EXIT SIGNAGE REQUIREMENTS 1.EACH GRADE-LEVEL EXTERIOR DOOR SHALL BE IDENTIFIED BY A TACTILE SIGN WITH THE WORD "EXIT". 2.EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS OF AN EXIT ENCLOSURE OR AN EXIT PASSAGEWAY IS IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS, "EXIT ROUTE". 3.EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS OF A STAIRWAY OR RAMP IS IDENTIFIED BY A TACTILE EXIT SIGN THAT STATES "EXIT STAIR DOWN", "EXIT RAMP DOWN", "EXIT STAIR UP" OR "EXIT RAMP UP", AS APPROPRIATE. 4.EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A CORRIDOR OR HALLWAY THAT IS REQUIRED TO HAVE A VISUAL EXIT SIGN IS IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS, "EXIT ROUTE". 5.EACH EXIT DOOR THROUGH A HORIZONTAL EXIT SHALL BE IDENTIFIED BY A SIGN WITH THE WORDS, "TO EXIT". 6.LETTERS ON SIGNS ARE RAISED 1/32", SANS SERIF UPPERCASE CHARACTERS AND ARE ACCOMPANIED BY GRADE 2 BRAILLE. 7.RAISED CHARACTERS ARE BETWEEN 5/8" AND 2" HIGH. 8.BRAILLE DOTS ARE 1/10" ON CENTER IN EACH CELL WITH 2/10" SPACE BETWEEN CELLS, MEASURED FROM THE SECOND COLUMN OF DOTS IN THE FIRST CELL TO THE FIRST COLUMN OF DOTS IN THE SECOND CELL. [NOTE: CA AND OTHER JURISDICTIONS ONLY] 9.BRAILLE DOTS ARE RAISED A MIN. OF 1/40" ABOVE THE BACKGROUND. 10.CHARACTERS AND BACKGROUND OF SIGNS IS EGGSHELL, MATTE, OR OTHER NON-GLARE FINISH. 11.CHARACTERS CONTRAST WITH THEIR BACKGROUND (LIGHT CHARACTERS ON A DARK BACKGROUND, OR DARK CHARACTERS ON A LIGHT BACKGROUND. 12.LETTERS ON SIGNS HAVE A WIDTH-TO-HEIGHT RATIO BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH-TO-HEIGHT BETWEEN 1:5 AND 1:10. 13.SIGNS ARE TO BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. (AT DOUBLE LEAF DOORS AND WHEN THERE IS NO WALL SPACE AT THE LATCH SIDE, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT.) 14.MOUNTING HEIGHT IS 60" MAX. FROM THE FINISHED FLOOR TO THE TOP OF THE SIGN. 15.MOUNTING LOCATION ALLOWS A PERSON TO APPROACH WITHIN 3" OF THE SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR. HINGE SIDE APPROACHFRONT APPROACH SWINGING DOOR PUSH SIDE NOTE: X=12" MIN. IF DOOR HAS BOTH A LATCH AND A CLOSER SWINGING DOOR PUSH SIDE NOTE: Y=48" MIN. IF DOOR HAS BOTH A LATCH AND A CLOSER SWINGING DOOR PULL SIDE FRONT APPROACH 60 " M I N . X 48 " M I N . Y SWINGING DOOR PULL SIDE NOTE: X=36" MIN. IF Y=60"; X=42" MIN. IF Y=60" MIN. HINGE SIDE APPROACH 18" MIN. 24" PREFERRED 54" MIN. 42 " M I N . ( Y ) X 48" MIN. LATCH SIDE APPROACH SWINGING DOOR PUSH SIDE NOTE: Y=48" MIN. IF DOOR HAS A CLOSER 24 " M A X . FO R M I N . C L E A R 60 " M I N . 24" MIN. 42 " M I N . ( Y ) LATCH SIDE APPROACH SWINGING DOOR PULL SIDE NOTE: Y=60" MIN. 24" MIN. 48" MIN. 42" MIN. 36" MIN. 32" MIN. 2 MANEUVERING CLEARANCES AT DOORS N.T.S. 7 FITTING ROOM ADA CLEARANCES N.T.S. 8 WHEELCHAIR TURNING REQUIREMENTS IN AN ACCESSIBLE ROUTE N.T.S. EQUIPMENT PERMITTED IN SHADED AREA HI LO NOTE: EQUIPMENT PERMITTED IN SHADED AREA 48" MIN. 24" MAX. 18"-19" 30 " M I N . CLACCESSIBLE HEIGHT UNIT EQ . EQ . 18" MIN. 48" MIN. 30 " M I N . 32 " M I N . C L E A R 36 " M I N . I F W I N G W A L L D E P T H I S > 2 4 " 5 DRINKING FOUNTAIN ADA CLEARANCES N.T.S. PAINT PER FINISH PLAN 36 " M A X . S P O U T H E I G H T 38 " M I N . - 4 3 " M A X . S P O U T H E I G H T ACCESSIBLE DRINKING FOUNTAINS. SEE PLUMBING DRAWINGS. SEE DETAIL A FOR KNEE CLEARANCES. PER PLAN A SPOUT HEIGHT. & KNEE CLR.B CLEAR FLOOR SPACE C BUILT-IN FOUTAIN / COOLER B DRINKING FOUTAIN OUTLET HT. 4' - 0 " H E I G H T W A I N S C O T P E R F I N I S H P L A N BE H I N D A N D S U R R O U N D I N G W A L L S , T Y P . X Z 48" 30"10" MAX.30" 48 " 54 ' M A X . 9" MI N . 30" 10" MAX. 48 " Y 48" 30" 30 " X Z 46 " M A X . 24" 34 ' MA X . 60" MIN. 60 " M I N . 6 WHEELCHAIR CLEAR FLOOR SPACE AND REACH REQUIREMENTS N.T.S. NOTE: X £25"; Z ³ 25" IF X < 20", Y = 48" MAX. IF X = 20" - 25", Y = 44" MAX. D HI & LO SIDE REACH LIMITS E MAX. FORWARD REACH OVER AN OBBSTRUCTION F MAX. SIDE REACH OVER AN OBBSTRUCTION A TURNING DIAMETER B CLEAR FLOOR SPACE C CLEAR FLOOR SPACE PARALLEL APPROACH 60 " M I N . 48 " M I N . 12" MIN. 36" MIN. 48" MIN.36" MIN.36" MIN.42" MIN.42" MIN. 36 " M I N . 60 " M I N . NOTE: X < 48" 60" MIN. X A 90° TURN RADIUS B TURN AROUND AN OBSTRUCTION C 'T'-SHAPE 180° TURNS D CLEAR. WIDTH FOR PASSING FOR TWO WHEELCHAIRS BENCH FULL LENGTH MIRROR. SEE MOUNTING DETAIL 2/A503. 24 " 48" 60 " M I N . 20 " M A X . 54 " M I N . 18" MIN. 17 " - 1 9 " A. F . F . 48"24" 17 " - 1 9 " A. F . F . CLEAR FLOOR SPACE 60" MIN. A TYPICAL ADA FITTING ROOM PLAN VIEW B ADA MIRROR ELEVATION C FRONT ADA BENCH ELEVATION D SIDE ADA BENCH ELEV. AND COAT HOOK HEIGHTS MAX HEIGHT FOR COAT HOOKS IS 46" A.F.F. SEE MOUNTING DETAIL 1/A522. 46 " M A X . G002 B D C BENCH IS TO BE FIXED TO THE WALL 1 CASHWRAP ADA CLEARANCES N.T.S. TOP OF FLOORING. BASE PER PLANS. 27 " M I N . 36 " M A X . 9" M I N . 6" MAX 8" MIN 5" MAX 15" MIN. A ADA COUNTER SIDE APPROCH PLAN 34 " M A X . 36" MIN. 36" MIN. 10 " M I N . 24 " M A X . NOTE: 1. REFER TO DRAWINGS BY OTHERS. 30 " CL E A R F L O O R AR E A 48" CLEAR FLOOR AREA G002 (CAL) ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 ACCESSIBILITY DETAILS 2 2 CALGREEN REQUIREMENTS G003 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 CALGREEN REQUIREMENTS G004 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 CALGREEN REQUIREMENTS G005 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 2'-6" CLR. ROUTE OF T R A V E L DISTANCE = 56'-0" MW FRIDGE S S SS S S S DSL LOCKERS HA R D W A R E B I N 24x48 24x48 LA D D E R S TRANSFORMER BA R B I N L-10 L-10 L-10 L-10 PR O C E S S I N G D E S K +4 2 " A . F . F . L-10 24x48 24x48 24x48 24x48 24x48 24x48 1.SEE SHEET G002 FOR ACCESSIBILITY SIGNAGE. 2.ACCESSIBILITY ROUTE OF TRAVEL SLOPES NOT TO EXCEED RUNNING SLOPE OF 1:20 (5%) MAXIMUM CROSS SLOPE OF 1:50 (2%). 3.SITE ACCESSIBILITY PROVIDED BY LANDLORD. 4.PROVIDE WALL MOUNTED FIRE EXTINGUISHER(S) PER FIRE MARSHAL'S INSTRUCTION. N 1 HOUR RATED WALL 2 HOUR RATED WALL 3 HOUR RATED WALL GENERAL NOTES 1 EGRESS PLAN 3/16" = 1'-0" HU N T I N G T O N D R I V E AREA OF TENANT IMPROVEMENT LEVEL 1 SPACE #: H-12, H-13, & H-14 REFER TO SITE PLAN SHEET FOR MORE INFORMATION. Fire Protection / Sprinkler Comments: 1.LANDLORD REQUIRES ALL TENANTS TO USE ONE OF LANDLORD'S PRE-QUALIFIED SPRINKLER CONTRACTORS FOR TENANT'S SPRINKLER WORK. TENANT MAY COMPETITIVELY BID TO ONLY THOSE SPRINKLER CONTRACTORS PRE-QUALIFIED BY LANDLORD. SEE DATA SHEET FOR REQUIRED CONTRACTORS. 2.THE SPRINKLER CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL DRAWINGS, DOCUMENTATION AND FLOW CALCULATIONS TO THE LOCAL AUTHORITY HAVING JURISDICTION IN ORDER TO OBTAIN ALL PROPER PERMITS. 3.IF LOCAL FIRE DEPARTMENT AND/OR AHJ DETERMINES ADDITIONAL SPRINKLER HEADS AND FIRE ALARM DEVICES WILL BE REQUIRED BASED ON TENANT IMPROVEMENTS, IT IS THE TENANT’S RESPONSIBILITY TO HIRE THE LANDLORD REQUIRED FIRE ALARM & FIRE SPRINKLER CONTRACTOR FOR THIS WORK. TENANT IS RESPONSIBLE FOR ANY CODE REQUIRED CHANGES OR UPGRADES TO EXISTING CONDITIONS. EXISTING BUILDING MONITORING SYSTEM PULL STATIONS AND HORN/STROBES MUST BE KEPT CLEAR OF ALL OBSTRUCTIONS. TENANT OR ITS GENERAL CONTRACTOR MUST VERIFY EXISTING LOCATIONS, AND MAKE ANY APPLICABLE CHANGES PER THE LOCAL JURISDICTION. 4.SPRINKLER SYSTEM SHALL BE FULLY CHARGED AND OPERATIONAL WHENEVER CONTRACTOR IS NOT ON SITE. 5.FIRE ALARM CONTRACTOR SHALL BE RESPONSIBLE FOR UPDATING ALL PROGRAMMING OF ADDRESSABLE DEVICES, SYSTEMS, ETC. OF THE NEWLY INSTALLED FIRE ALARM DEVICES TO SATISFY THE REQUIREMENTS OF THE LOCAL AHJ. 6.FIRE ALARM CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL DRAWINGS, DOCUMENTATION, BATTERY CALCULATIONS, ETC. TO THE LOCAL AHJ TO OBTAIN ALL NECESSARY PERMITS. 7.PLAN SUBMISSIONS FOR TENANT IMPROVEMENT PROJECTS MUST BE EMAILED TO LANDLORD. 8.ALL LANDLORD EQUIPMENT, COMPONENT, AND / OR SERVICES FEEDING OTHER TENANT(S) THAT ARE EXISTING IN THE SPACE SHALL REMAIN VISIBLE AND ACCESSIBLE TO THE LANDLORD. TENANT SHALL INSTALL ACCESS PANELS AS REQUIRED TO MAINTAIN ACCESS AND SHALL BE LABELED TO PROPERLY IDENTIFY SYSTEMS. TENANT SHALL COORDINATE LOCATION WITH MALL OPERATIONS TEAM. 8.TENANT DISPLAY FIXTURES IN THE RETAIL SPACE AND RACK / SHELVING / STORAGE UNITS IN THE STOCKROOM SHALL BE DESIGNED TO PROVIDE ADEQUATE CLEARANCE FOR THE AUTOMATIC (FIRE) SPRINKLER SYSTEM. NO DISPLAYS OR STORAGE SHOULD EXCEED 12 FEET AND CEILINGS MUST BE INSTALLED TO PROVIDE A MINIMUM OF 18" OF CLEARANCE BETWEEN THE TOP OF THE STORAGE SYSTEM AND SPRINKLER DEFLECTORS. 9.TENANT DISPLAYS OR STORAGE HIGHER THAN 12'-0" ARE CLASSIFIED AS "HIGH PILED STORAGE", WHICH REQUIRES HIGH HAZARDOUS AUTOMATIC (FIRE) SPRINKLER PROTECTION DESIGNED PER FM GLOBAL LOSS PREVENTION DATA SHEET AND NFPA REQUIREMENTS FOR THE STORAGE OF "GROUP A PLASTIC" COMMODITIES. HIGH PILED STORAGE ALSO REQUIRES A MINIMUM OF 36" OF CLEARANCE BETWEEN THE TOP OF STORAGE AND SPRINKLER DEFLECTORS. 10.TENANT SHALL NOT DRILL, WELD, SCREW, SHOOT, AND / OR PENETRATE LANDLORD’S BUILDING STRUCTURE, FLOOR DECK, AND / OR ROOF DECK. TENANT MAY NON-DESTRUCTIVELY ATTACH OR SUSPEND FROM, UTILIZING ALTERNATIVE METHODS OF ATTACHMENT, THE TOP CHORD OF THE JOIST OR THE STRUCTURAL STEEL WHICH EXISTS WITHIN THE PREMISES WITH AN EVALUATION COMPLETED BY THE TENANT’S STRUCTURAL ENGINEER OF THE EXISTING STRUCTURE AND DETERMINATION THAT IT IS SUFFICIENT FOR THE ADDITIONAL LOAD IN ACCORDANCE WITH THE BUILDING CODE THAT HAS BEEN ADOPTED BY THE AUTHORITIES HAVING JURISDICTION (AHJ). REFER TO STRUCTURAL MODIFICATION REQUIREMENTS FIRE PROTECTION / SPRINKLER NOTES HU N T I N G T O N B O U L E V A R D BALDWIN AVEN U E GATE 8 GENERAL LOCATION OF TENANT IMPROVEMENT. REFER TO SITE PLAN SHEET FOR MORE INFORMATION LEVEL 2 OF 3, SPACES: H-12, H-13, & H-14 KEY MAP VICINITY MAP STRUCTURAL COLUMNS ADJACENT TENANT STOCK ROOM SALES AREA EXIT 1 ADJACENT TENANT FE EXIT SIGNAGE RO U T E O F T R A V E L DI S T A N C E = 64 ' - 0 " EXIT 3 FITTING ROOMS HALLWAY FIRE EXTIR. MOUNT HEIGHT AT 48" MAX. RO U T E O F T R A V E L DI S T A N C E = 79 ' - 0 " UNISEX TOILET ROOM MALL CORRIDOR EXIT SIGNAGE ROUTE OF TRAVEL DISTANCE = 42'-8" DIAG O N A L D I S T A N C E = 113'- 7 " DIVID E D B Y 3 = 37'-1 0 " (MIN I M U M D I S T A N C E B E T W E E N E X I T S ) 66'-0" DISTANCE BETWEEN EXITS UNISEX TOILET ROOM ROUTE OF TRAVEL DISTANCE = 56'-0" BUG EYE EMERGENCY LIGHT TO BE MOUNTED AT MIN. OF 12'-0" AND TIGHT TO THE CEILING AS POSSIBLE. TYP BUG EYE EMERGENCY LIGHT TO BE MOUNTED AT MIN. OF 12'-0" AND TIGHT TO THE CEILING AS POSSIBLE. TYP RO U T E O F T R A V E L DI S T A N C E = 42 ' - 8 " 3'-8" CLR 4'-10" CLR 4' - 1 " 5' - 3 " CL R 4'- 6 " EQEQEQ EQEQEQ EQ EQ EQ EQ EQ EQ EQ 1'-0" EQ EQ 3'-4 1/8" ROUTE OF TRAVEL DISTANCE = 80-6" 4'-4" CLR. 3' - 3 1 / 2 " 3' - 1 1 " 3' - 0 " 3' - 3 " 3'- 8 " CL R . 2' - 7 " 3' - 0 " 3' - 3 " 3' - 0 " 3'- 4 " 3' - 5 " 3'-0"4'-0"3'-0" 3'-0"3'-0"4'-0" 3'-4"3'-0"3'-0" 5'-0" 6'- 0 " 6' - 5 " 3' - 8 " CL R . 4' - 0 " 3'-8" CLR. 3'-8" CLR.3'-9"4'-11"4'-0" 4'-0" 3'-4"3'-0"3'-7"3'-8"3'-0"3'-0"5'-6"3'- 0 " 4' - 4 " 3' - 0 " 3'-0"3'-0"4'-0" 3'-0" 3'-0"3'-9" 4'- 6 " 4' - 0 " 5' - 0 3 / 8 " 6'-11" 9'- 3 " 3'- 8 " CL R . NEW STRUCTURAL COLUMNS (E) COLUMN (E) COLUMN 3'- 1 1 " 9" TACTILE SIGNAGE (E) COLUMN STRUCTURAL COLUMNS STRUCTURAL COLUMNS 4'-3 1/ 2 " 4'-1 1 / 2 " (E) VOID NEW STRUCTURAL COLUMNS NEW STRUCTURAL COLUMNS 3'- 8 " CL R . NEW STRUCTURAL COLUMNS 3' - 0 " CL R . PROVIDE YELLOW STRIPING ON THE FLOOR FOR 44" CLEAR PATH OF TRAVEL TO REAR EXIT DOOR. 3'- 8 " CL R . 3'- 8 " CL R . 3'- 8 " CL R . EXIT SIGNAGE EXIT 2 ROUTE OF TRAVEL DISTANCE = 66'-0" ROUTE OF TRAVEL DISTANCE = 66'-0" TACTILE SIGNAGE G101 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/25/23 07/24/23 BUILDING COMMENTS KEY PLAN, VICINITY MAP & EGRESS PLAN 1 1 2 2 22 2 2 2 2 2 2 3 2 2 2 2 2 2 3 3 1.G.C. TO VERIFY FIELD CONDITIONS AND DIMENSIONS AND NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES. 2.G.C. TO CONSTRUCT A BARRICADE PRIOR TO ANY WORK IS DONE ON SITE. TEMPORARY BARRICADE WALL/ENTRANCE TEMPORARY BARRICADE WALL WALL GRAPHIC WHITE W/ PACSUN LOGO BLACK 2'-6 1/2" V.I.F. TEMPORARY BARRICADE WALL 1 TEMPORARY BARRICADE WALL 3/8" = 1'-0" GROUND 0'-0" 5 TEMPORARY BARRICADE WALL 3/8" = 1'-0" GROUND 0'-0" T.O. BARRICADE 15'-10" V.I.F. 2 TEMPORARY BARRICADE WALL 3/8" = 1'-0" GROUND 0'-0" 49'-10 1/2" V.I.F. 12'-11 1/2" V.I.F. 2'-3 1/2" V.I.F. TEMPORARY BARRICADE WALL 4 TEMPORARY BARRICADE WALL 3/8" = 1'-0" GROUND 0'-0"TEMPORARY BARRICADE WALL 3 A207 GROUND 0'-0" 6 - LEASE LINE (V.I.F.) 34" MARINE GRADE PLYBOARD SEALED TO CONTAIN DUST, NOISE, ETC. PACSUN SUPPLIED GRAPHICS. REFER TO MALL DESIGN REQ. 3 5/8" 25 GA. MTL. STUD @ 24" O.C. WITH 3 4" MARINE GRADE PLYBOARD. FINISH, TAPED AND SPACKLED TO RECEIVE GRAPHICS. 3'-0" MAX. ;1 5 ' - 1 0 " VA R I E S W / S T O R E CO N D I T I O N ; V . I . F . NOTE: L.L. G.C TO REPAIR FACADE FOR ANY DAMAGES INCURRED DURING CONSTRUCTION. T.O. BARRICADE 15'-10" V.I.F. B.O. HEADER 10'-0" 3 - 5 - 2 - 1 - 49'-10 1/2" 1 2 ' - 1 1 1 / 2 " 2'-6 3 / 8 " 3' - 0 " 2 ' - 3 1 / 2 " 7 TEMPORARY BARRICADE WALL - PLAN VIEW 3/8" = 1'-0" 6 TEMPORARY BARRICADE WALL SECTION 3/8" = 1'-0" 17'-6 1 / 2 " 4 - 3 TEMPORARY BARRICADE WALL 3/8" = 1'-0" GROUND 0'-0"TEMPORARY BARRICADE WALL 17'-6 1/2" V.I.F. T.O. BARRICADE 15'-10" V.I.F. T.O. BARRICADE 15'-10" V.I.F. T.O. BARRICADE 15'-10" V.I.F. T.O. BARRICADE 15'-10" V.I.F. FINES WILL BE IMPOSED FOR EACH INFRACTION STATED BELOW: 1.TENANT AND GENERAL CONTRACTOR SHALL ENSURE THAT THE WORKPLACE IS IN STRICT COMPLIANCE WITH OSHA AND MALL SAFETY GUIDELINES. WHERE THERE IS DISPUTE BETWEEN OSHA AND MALL SAFETY GUIDELINES, THE STRICTER GUIDELINE SHALL BE ENFORCED. 2.TENANT AND TENANT G.C. SHALL WEAR THE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT (PPE) TO PREVENT INJURY TO THEIR PERSONNEL AND OTHER PERSONS ON THE JOB SITE. HARD HATS REQUIRED. HIGH VISIBILITY VESTS OR SHIRTS ARE STRONGLY RECOMMENDED. PROPER FOOTWEAR AND CLOTHING ARE REQUIRED WITHIN THE NEW CONSTRUCTION AREA TO PREVENT INJURY. 3.INTERIOR WORK MAY OCCUR 24 HOURS A DAY. NOISE AND ORDERS THAT CAN DISTURB CUSTOMERS AND NEIGHBORING TENANT IS LIMITED TO NON-OPERATING HOURS; HOWEVER CONSTRUCTION PROJECTS WITHIN THE FOOD COURT AREA REQUIRE VARIOUS ADDITIONAL OPERATING APPROVALS BY MALL MANAGEMENT. 4.GENERAL CONTRACTOR AND SUBCONTRACTORS ARE TO USE DESIGNATED PARKING AS INSTRUCTED BY THE LANDLORD DURING OPEN MALL HOURS OF 10:00AM AND 9:00PM. A FINE WILL BE IMPOSED FOR ANY VEHICLE PARKING IN NON-DESIGNATED AREAS WHEN THE MALL IS OPEN. REPEAT IN VIOLATION WILL RESULT IN TOWING AT VEHICLE OWNER'S EXPENSE. REFER TO SITE PLAN. 5.USE OF TOXIC SUBSTANCE INCLUDING FLOOR SEALANT AND PAINT PRODUCTS SHALL BE SCHEDULED WITH MANAGEMENT AND WILL NOT BE ALLOWED BETWEEN THE HOURS OF 6:00AM AND 10:00PM OF EACH DAY. IF USED WITHIN THOSE HOURS OPERATION WILL BE DISCONTINUED, AND THE SITE WILL BE SHUT DOWN UNTIL APPROVAL TO PROCEED WORK IS GRANTED BY MANAGEMENT AND OSHA. 6.ALL WORKERS BREAKS SHOULD BE TAKEN INSIDE THE WORK AREA, ADJACENT LOADING DOCK OR AN EATING ESTABLISHMENT. NO WORKERS MAY CONGREGATE IN THE MALL INTERIOR AREA DURING MALL HOURS. 7.WORKERS MUST FOLLOW THE DIRECTIVES OF THE RETAIL DELIVERY TEAM OR SECURITY STAFF. ANY WORKER FOUND TO BE IN DISPUTE WITH MALL PATRONS OR STAFF WILL BE ESCORTED FROM THE PREMISES. 8.TOOLS, WORK MATERIAL AND SUPPLIES SHALL BE CONFINED TO THE WORK PREMISES. NO WORK IS TO BE CONDUCTED OR MATERIALS BE STORED IN SERVICE CORRIDORS, LOADING DOCKS OR MALL COMMON AREAS. 9.CONTRACTOR AND SUBCONTRACTORS ARE NOT TO USE PUBLIC RESTROOMS TO CLEAN THEIR TOOLS. 10.IT IS THE GENERAL CONTRACTOR’S RESPONSIBILITY TO SECURE TOOLS, EQUIPMENT, AND MATERIALS AT THE END OF EACH DAY. GENERAL CONTRACTOR MUST PROVIDE AN ENTRY CARPET WITHIN THEIR BARRICADE TO PREVENT DUST FROM TRAILING OUT TO THE MALL COMMON AREA. GENERAL CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE MOPPING AND SWEEPING OF COMMON AREAS FREE OF CONSTRUCTION DIRT AND DEBRIS. 11.TENANT AND GENERAL CONTRACTOR SHALL PROTECT THEIR WORK FROM DAMAGE AND SHALL PROTECT THE WORK OF OTHER TENANTS AND LANDLORD FROM DAMAGE BY TENANT, GENERAL CONTRACTOR AND/OR EMPLOYEES AND SUB-CONTRACTORS. CONTRACTOR WORK AREA AND PRACTICES NOTES FINES WILL BE IMPOSED FOR EACH INFRACTION STATED BELOW: 1.BARRICADES CONSTRUCTION COST WILL BE BORN / REIMBURSED BY THE CONTRACTOR. 2.BARRICADES WITH GRAPHICS ARE REQUIRED FOR ALL STORE REMODELS AND RENOVATIONS AND WILL REQUIRE MANAGEMENT APPROVAL, AND THEN BE PROVIDED BY THE LANDLORD OR CONSTRUCTED BY THE CONTRACTOR AS DETERMINED BY THE TENANT LEASE. 3.PRIOR TO THE START OF CONSTRUCTION, A MANDATORY PRE-CONSTRUCTION MEETING BETWEEN MANAGEMENT AND THE GENERAL CONTRACTOR MUST BE HELD. THIS MEETING MUST BE SCHEDULED AT LEAST THREE (3) DAYS PRIOR TO THE PROPOSED START DATE WITH THE REQUIRED DOCUMENTS. 4.BARRICADE GRAPHICS 4.1.BARRICADE GRAPHICS ARE ADDITIONAL AT THE TENANT OR TENANT CONTRACTOR'S EXPENSE. 4.2.ALL QUESTIONS REGARDING BARRICADE GRAPHIC REQUIREMENTS MUST BE SUBMITTED TO MANAGEMENT. 4.3.ALL BARRICADE GRAPHICS ARE REQUIRED AND MUST BE APPROVED BY MANAGEMENT. GRAPHICS MUST BE INSTALLED WITHIN 72 HOURS OF BARRICADE INSTALLATION. 5.TENANT G.C. OR SUBCONTRACTORS WILL NOT BE ALLOWED TO POST ANY SIGNAGE CONTAINING THE NAME OR ADVERTISING OF THEIR FIRM TO ANY PART OF THE BARRICADE, SHOPPING CENTER, OR PREMISES AT ANY TIME WITHOUT APPROVAL. 6.LANDLORD RESERVES THE RIGHT TO POST A NOTICE OF NON-RESPONSIBILITY ON ANY ENTRY INTO SPACE AS REQUIRED BY TENANT'S LEASE. 7.BARRICADES MAY NOT BE MORE THAN FOUR (4) FEET FROM THE STOREFRONT. 8.ALL BARRICADES ARE REQUIRED TO HAVE A HARD LID. 9.BARRICADES ONCE IN PLACE, CANNOT BE REMOVED WITHOUT THE APPROVAL OF MANAGEMENT. 10.NO FOOT TRAFFIC WILL BE PERMITTED THROUGH THE BARRICADE DURING MALL HOURS, USE BACKDOOR WHERE APPLICABLE. 11.ALL FINISHED MALL AREAS, INCLUDING SOFFITS, ARE TO BE RETURNED TO THEIR ORIGINAL CONDITION WHEN CONSTRUCTION IS COMPLETE AND BARRICADE IS REMOVED. 12.THE SURFACES WHERE THE BARRICADE HAS BEEN FASTENED TO THE MALL MUST BE REPAIRED AND PAINTED TO MATCH EXISTING MALL COLOR. MATCHING PAINT COLORS CAN BE OBTAINED FROM THE MALL MAINTENANCE OFFICE. 13.ALL MALL FLOORING INSIDE THE BARRICADE MUST BE PROTECTED AT ALL TIMES. FLOORING: ANY CHIPS, HOLES OR SCRATCHES, TAPE RESIDUE IN OR ON THE MALL FLOORING FROM DEMOLITION OF THE OLD STOREFRONT OR CONSTRUCTION THAT WILL REMAIN EXPOSED AFTER NEW CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR. 14.ANY QUESTIONS OR CONCERNS THAT MAY ARISE REGARDING THESE RULES DURING THE CONSTRUCTION OF TENANT SPACE SHOULD BE BROUGHT TO MANAGEMENT IMMEDIATELY. STOREFRONT BARRICADE POLICY GENERAL NOTES BARRICADE PLAN AND ELEVATIONS A100 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 KEYED NOTES NOTES 1 REMOVE STOREFRONT SYSTEMS, GLAZING, AND DOORS IN THEIR ENTIRETY. 2 EXISTING DEMISING WALL TO REMAIN. PATCH AND REPAIR AS REQUIRED. 3 LEASE LINE 4 EXISTING FLOORING AND WALL TILE TO BE REMOVED PREPARE FOR INSTALLATION OF NEW FLOORING AND WALL MATERIALS AS INDICATED IN THESE PLANS. SEE SPECIFICATIONS FOR ADDITIONAL FLOOR PREPARATION NOTES. 5 EXISTING SERVICE DOOR TO REMAIN. SEE DOOR SCHEDULE FOR NEW HARDWARE. 6 EXISTING STRUCTURAL COLUMN TO REMAIN. 7 EXISTING DOOR AND HARDWARE TO BE REMOVED. 8 DIMENSIONS TO GIVE LOCATION OF TRENCH/CORE DRILL. REFER TO ELECTRICAL DRAWINGS FOR MORE INFORMATION. 9 ELECTRICAL FLOOR BOX , ELECTRICAL AND DATA FOR 3 POS STATIONS. REFER TO ELECTRICAL DRAWINGS FOR CONDUIT SIZE. SEE SHEET A561 FOR ADDITIONAL SLAB/TRENCH INFORMATION. 10 EXISTING INTERIOR WALL TO BE REMOVED IN ITS ENTIRETY. 11 EXISTING TOILET ROOM, PLUMBING FIXTURES, WALLS, DOOR, CEILING SYSTEM, AND LIGHT FIXTURES TO BE REMOVED IN THEIR ENTIRETY. PATCH AND REPAIR AS NEEDED TO PREPARE FOR NEW FINISHES AS INDICATED IN THESE PLANS. 12 EXISTING FURRING TO REMAIN. PATCH AND REPAIR AS NEEDED. PREP FOR FINISHES. 13 EXISTING CEILING, LIGHT FIXTURES, AND DIFFUSERS TO BE REMOVED IN THEIR ENTIRETY. 14 EXISTING ADJACENT TENANT'S STOREFRONT TO REMAIN IN ITS ENTIRETY, N.I.S. 15 EXISTING DEMISING WALL TO BE REMOVED IN ITS ENTIRETY. PATCH AND REPAIR AS REQUIRED. 16 EXISTING SERVICE DOOR TO BE CLOSED, LOCKED AND WELDED SHUT. 17 DEMO SECTION OF WALL FOR NEW RATED EXIT DOOR - COORDINATE WITH MALL. ##1.CHECK MECHANICAL AND ELECTRICAL DRAWINGS PRIOR TO DEMOLITION WITH REGARD TO UTILIZING ANY EXISTING WIRING, LINES, COMPONENTS, ETC. 2.PROVIDE TRASH CONTAINER AS REQUIRED AT LOCATION TO SUIT LANDLORD. REMOVE DEBRIS DAILY AND HAUL FROM THE SITE AT TIME TO SUIT LANDLORD. 3.NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES OR UNFORESEEN ITEMS NOT SHOWN ON DRAWINGS. 4.ALL REMOVED MATERIAL AND DEBRIS, NOT OTHERWISE DESIGNATED, BECOMES THE PROPERTY OF THE CONTRACTOR, WHO SHALL REMOVE IT FROM THE SITE. 5.G.C. SHALL NOT DEMOLISH ANY LOAD BEARING WALLS OR CONSTRUCTION THAT WILL COMPROMISE THE STRUCTURAL INTEGRITY OF THE EXISTING SPACE. G.C. TO NOTIFY THE ARCHITECT IMMEDIATELY OF ANY STRUCTURAL CONCERNS DURING DEMOLITION. 6.EXISTING EQUIPMENT NOT BEING USED MUST BE COMPLETELY REMOVED / DISPOSED OF PROPERLY. NOTHING CAN BE ABANDONED ABOVE THE CEILING. 7.REMOVE EXISTING ACOUSTICAL CEILING GRID AND TILES, LIGHT FIXTURES, AND GYPSUM WALLBOARD SOFFITS AS SCHEDULED FOR DEMOLITION AND AS REQUIRED BY PARTITION DEMOLITION AND NEW CONSTRUCTION WORK. MAINTAIN EXISTING CEILING WIRE HANGERS FOR FUTURE USE. 8.REMOVE EXISTING ELECTRICAL DEVICES, OUTLETS, TELEPHONE AND DATA JACKS AND THERMOSTATS IN PARTITIONS SCHEDULED FOR DEMOLITION. MODIFY EXISTING WIRING AS REQUIRED BY NEW CONSTRUCTION OR, IF NOT REQUIRED, TERMINATE AND CAP OFF AT NEAREST PANEL OR SOURCE ABOVE CEILING. 9.REMOVE EXISTING FLOOR FINISHES SCHEDULED FOR REMOVAL AND AS REQUIRED BY PARTITION DEMOLITION AND NEW CONSTRUCTION. PREPARE EXISTING FLOOR SURFACE PER MANUFACTURER FOR INSTALLATION OF NEW FLOORING MATERIAL AS INDICATED IN THESE PLANS. G.C. MAY NEED TO PERFORM A MOISTURE TEST PRIOR TO ANY DEMOLITION OR NEW FLOORING INSTALLATION. NEWLY REPLACED OR LIKE-NEW FINISHES MAY REMAIN AT THE DISCRETION OF THE CONSTRUCTION PM. G.C. TO VERIFY PRIOR TO REMOVAL. PROTECT ALL NEW FLOOR FINISHES UNTIL FINAL CLEANING. 10.REMOVE ALL CONSTRUCTION DEBRIS FROM AREA. REPAIR ALL ADJACENT DAMAGED SURFACES, AS NECESSARY. PREPARE ALL DAMAGED SURFACES FOR FINISHES AS SCHEDULED OR REFINISH TO MATCH EXISTING FINISH. 11.PROVIDE A SMOOTH, NEAT, AND CONTINUOUS APPEARANCE WHERE DEMOLITION WORK MEETS ADJACENT EXISTING WORK. REMOVE EXISTING FINISHES AS REQUIRED TO PROVIDE NEAT, STRAIGHT SEAMS AND TRANSITIONS BETWEEN EXISTING AND MATCHING NEW FINISHES. 12.IN ACCORDANCE WITH LOCAL CODES, REPLACE ALL FIRE SUPPRESSION AND FIRE ALARM EQUIPMENT DISTURBED BY DEMOLITION WORK. MAINTAIN INTEGRITY OF FIRE SUPPRESSION AND FIRE ALARM SYSTEMS. 13.IN THE CASE THAT THE EXISTING CABLE LINE, PHONE LINE AND BLOCK, T-1 LINE AND DATA CABLING ARE PRESENT, G.C. SHALL SALVAGE AND REWORK TO FACILITATE NEW INSTALLATION 14.G.C. SHALL CONSTRUCT A BARRICADE WALL AS REQUIRED. G.C. SHALL COORDINATE REQUIREMENTS WITH MALL PROPERTY MANAGEMENT. 15.BARRICADE GRAPHICS SHALL BE PROVIDED BY MALL UNLESS OTHERWISE REQUESTED. G.C. SHALL ENGAGE PACSUN'S SIGN VENDOR FOR BARRICADE GRAPHICS AS REQUIRED. 16.FIRE SPRINKLER SYSTEM TO REMAIN - G.C. TO RE-WORK/ MODIFY SYSTEM AS REQUIRED FOR NEW CONSTRUCTION. 17.WHERE REQUIRED BY THE LOCAL JURISDICTION, G.C. SHALL PREPARE A "RECYCLING PLAN" TO DIVERT DEBRIS FOR RECYCLING. G.C. SHALL KEEP RECORDS OF DIVERTED MATERIAL AS REQUIRED. G.C. TO VERIFY REQUIREMENTS WITH JURISDICTION AND TO MALL OPERATIONS/ LANDLORD WHERE APPLICABLE. 18.REMOVE ALL EXISTING INTERIOR PARTITIONS, DOORS, AND DOOR FRAMES SCHEDULED FOR DEMOLITION. REMOVE ALL MILLWORK, EQUIPMENT, ETC. THAT IS ATTACHED TO PARTITIONS SCHEDULED FOR DEMOLITION. 19.REMOVE EXISTING HVAC CEILING DIFFUSERS AND RETURN GRILLES AS SCHEDULED FOR DEMOLITION AND AS REQUIRED BY PARTITION DEMOLITION AND NEW CONSTRUCTION. MODIFY EXISTING DUCTWORK AS REQUIRED BY NEW CONSTRUCTION, OR IF NOT REQUIRED, TERMINATE AND CAP OFF SUPPLY AND RETURN DUCTS AT NEAREST SOURCE ABOVE CEILING. 20.REMOVE ALL EXISTING PLUMBING FIXTURES, FITTINGS, AND PIPING AS SCHEDULED FOR DEMOLITION AND AS REQUIRED BY PARTITION DEMOLITION AND NEW CONSTRUCTION. MODIFY EXISTING PIPING AS REQUIRED BY NEW CONSTRUCTION, OR IF NOT REQUIRED, TERMINATE AND CAP OFF AT WET STACK. 21.REMOVAL/RELOCATION OF ALL CEILING EQUIPMENT (TYCO, FIRE ALARM, SPRINKLER, SHOPPER TRAK, ETC.) MUST BE PERFORMED BY THE REQUIRED VENDORS. PACSUN'S VENDOR TO RELOCATE SECURITY CAMERAS AS NEEDED PER NEW FIXTURE LAYOUT. COORDINATE WITH PACSUN'S PROJECT MANAGER. 22.G.C. TO CONFIRM FLOOR SLAB IS SMOOTH AND LEVEL AND NOTIFY CONSTRUCTION PM OF ANY DISCREPANCIES. 23.MAINTAIN EXISTING EXITS, EMERGENCY LIGHTING, AND ILLUMINATION MEANS OF EGRESS DURING DEMOLITION AND CONSTRUCTION AS REQUIRED BY JHA AND ALL GOVERNING CODES. 24.SAW-CUTTING SHOWN ON PLANS IS AN INDICATION OF THE INTENDED WORK FOR BIDDING AND COORDINATION PURPOSES ONLY. IT IS NOT INTENDED TO BE A SPECIFICATION OR METHOD. 25.WHEN EXISTING MECHANICAL SYSTEM IS TO REMAIN, G.C. TO CLEAN DUCTWORK, DIFFUSERS, AND REPLACE HVAC AIR FILTERS AFTER CONSTRUCTION AND CLEANUP IS COMPLETE PRIOR TO TURNING PROJECT OVER TO PACSUN. 26.DURING CONSTRUCTION, THE G.C. IS TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A WITHIN 75 FOOT TRAVEL DISTANCE TO ALL PORTIONS OF THE SPACE. 1.GENERAL CONTRACTOR AND/OR SUBCONTRACTORS SHALL REVIEW THE EXISTING FACILITY TO DETERMINE THE EXTENT OF DEMOLITION REQUIRED TO INSTALL THE NEW WORK. A WRITTEN OUTLINE OF ALL REQUIRED DEMOLITION SHALL BE SUBMITTED TO THE PACSUN DESCRIBING THE FOLLOWING (BUT NOT LIMITED TO): 1.1.CONDITION OF EXISTING POWER PANELS AND TRANSFORMERS; FEASIBILITY FOR RELOCATION AND REFURBISHING, OR NEED FOR REPLACEMENT DUE TO AGE OR EXISTING CONDITION. 1.2.CONDITION OF EXISTING GYPSUM BOARD ON EXISTING DEMISING WALLS AND RECOMMENDATION OF WHETHER TO REMOVE EXISTING OR REUSE TO BE DETERMINED IN FIELD. 1.3.SUMMARIZE RECOMMENDATIONS FOR REUSE OF EXISTING MATERIALS, EQUIPMENT AND ACCESSORIES. ONCE REFURBISHED TO A LIKE-NEW CONDITION, ITEMIZE THE CREDIT TO THE CONTRACT. 1.4.TENANT G.C. SHALL NOTIFY ARCHITECT OF ANY UN-NOTED EXISTING CONDITION WHICH CONFLICTS WITH THE PROJECT REQUIREMENTS AND MAY REQUIRE MODIFICATION, RELOCATION, OR REMOVAL TO COMPLETE THE PROJECT WITHIN 24 HOURS SO THAT THE NECESSARY DRAWING REVISIONS MAY BE INCORPORATED INTO THE PROJECT REQUIREMENTS. 1.5.IN ADDITION TO THE ABOVE, REFER TO GENERAL DEMOLITION NOTES INDICATED IN SPECIFICATION DIVISION 2 - DEMOLITION / BUILDING ALTERATION. 1.6.CONDITION OF EXISTING MECHANICAL SYSTEM; FEASIBILITY OF REUSING, RELOCATION, OR REFURBISHING EXISTING EQUIPMENT AND DUCTWORK; AND RECOMMENDATION OF REPLACEMENT, IF NECESSARY, PRIOR TO BID. SEE MECHANICAL DRAWINGS FOR SCOPE OF MECHANICAL WORK 2.WHEN EXISTING CEILING IS TO REMAIN, REPLACE INDIVIDUAL CEILING TILES IF DAMAGED OR NOT MATCHED TO ADJACENT TILES. IF MORE THAN 25% ARE DAMAGED OR NOT MATCHED TO ADJACENT TILES, G.C. TO REPORT CONDITION AND COORDINATE EXTENT OF REPLACEMENT WITH CONSTRUCTION PM. GENERAL NOTESSCOPE SUMMARY 1 DEMOLITION FLOOR PLAN 1/4" = 1'-0"N TRENCH NOTES 1.SLAB PENETRATIONS SHALL BE MADE WITH PROPER LOCATION AND X-RAY IDENTIFICATIONS OF EXISTING REBAR AND/OR POST TENSION CABLES. 3 9 1 3 2 2 4 5 7 7 7 7 10 10 10 13 10 MALL 8 6'-0" 22 ' - 1 " H-12 SPACE H-13 SPACE H-14 SPACE 2 A103 1 1 1 1 1 1 1 2 2 2 2 22 3 3 3 3 3 4" V . I . F . 2'-2" V.I.F. 15 15 14 16 6 6 6 10 10 1015 7 7 7 1011 11 11 10 7 7 7 10 10 15 4 13 4 13 10 CORRIDOR ADJACENT TENANT ADJACENT TENANT VOID 12 3 A103 18 ' - 7 " 3' - 4 " 17 A101 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 DEMOLITION FLOOR PLAN 2 KEYED NOTES NOTES 1 EXISTING CEILING, LIGHT FIXTURES, AND DIFFUSERS TO BE REMOVED IN THEIR ENTIRETY. 2 CEILING ACCESS PANEL TO BE REMOVED. 3 EXISTING SOFFIT, LIGHT FIXTURES, AND DIFFUSERS TO BE REMOVED IN THEIR ENTIRETY. ##1.CHECK MECHANICAL AND ELECTRICAL DRAWINGS PRIOR TO DEMOLITION WITH REGARD TO UTILIZING ANY EXISTING WIRING, LINES, COMPONENTS, ETC. 2.PROVIDE TRASH CONTAINER AS REQUIRED AT LOCATION TO SUIT LANDLORD. REMOVE DEBRIS DAILY AND HAUL FROM THE SITE AT TIME TO SUIT LANDLORD. 3.NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES OR UNFORESEEN ITEMS NOT SHOWN ON DRAWINGS. 4.ALL REMOVED MATERIAL AND DEBRIS, NOT OTHERWISE DESIGNATED, BECOMES THE PROPERTY OF THE CONTRACTOR, WHO SHALL REMOVE IT FROM THE SITE. 5.G.C. SHALL NOT DEMOLISH ANY LOAD BEARING WALLS OR CONSTRUCTION THAT WILL COMPROMISE THE STRUCTURAL INTEGRITY OF THE EXISTING SPACE. G.C. TO NOTIFY THE ARCHITECT IMMEDIATELY OF ANY STRUCTURAL CONCERNS DURING DEMOLITION. 6.EXISTING EQUIPMENT NOT BEING USED MUST BE COMPLETELY REMOVED / DISPOSED OF PROPERLY. NOTHING CAN BE ABANDONED ABOVE THE CEILING. 7.REMOVE EXISTING ACOUSTICAL CEILING GRID AND TILES, LIGHT FIXTURES, AND GYPSUM WALLBOARD SOFFITS AS SCHEDULED FOR DEMOLITION AND AS REQUIRED BY PARTITION DEMOLITION AND NEW CONSTRUCTION WORK. MAINTAIN EXISTING CEILING WIRE HANGERS FOR FUTURE USE. 8.REMOVE EXISTING ELECTRICAL DEVICES, OUTLETS, TELEPHONE AND DATA JACKS AND THERMOSTATS IN PARTITIONS SCHEDULED FOR DEMOLITION. MODIFY EXISTING WIRING AS REQUIRED BY NEW CONSTRUCTION OR, IF NOT REQUIRED, TERMINATE AND CAP OFF AT NEAREST PANEL OR SOURCE ABOVE CEILING. 9.REMOVE EXISTING FLOOR FINISHES SCHEDULED FOR REMOVAL AND AS REQUIRED BY PARTITION DEMOLITION AND NEW CONSTRUCTION. PREPARE EXISTING FLOOR SURFACE PER MANUFACTURER FOR INSTALLATION OF NEW FLOORING MATERIAL AS INDICATED IN THESE PLANS. G.C. MAY NEED TO PERFORM A MOISTURE TEST PRIOR TO ANY DEMOLITION OR NEW FLOORING INSTALLATION. NEWLY REPLACED OR LIKE-NEW FINISHES MAY REMAIN AT THE DISCRETION OF THE CONSTRUCTION PM. G.C. TO VERIFY PRIOR TO REMOVAL. PROTECT ALL NEW FLOOR FINISHES UNTIL FINAL CLEANING. 10.REMOVE ALL CONSTRUCTION DEBRIS FROM AREA. REPAIR ALL ADJACENT DAMAGED SURFACES, AS NECESSARY. PREPARE ALL DAMAGED SURFACES FOR FINISHES AS SCHEDULED OR REFINISH TO MATCH EXISTING FINISH. 11.PROVIDE A SMOOTH, NEAT, AND CONTINUOUS APPEARANCE WHERE DEMOLITION WORK MEETS ADJACENT EXISTING WORK. REMOVE EXISTING FINISHES AS REQUIRED TO PROVIDE NEAT, STRAIGHT SEAMS AND TRANSITIONS BETWEEN EXISTING AND MATCHING NEW FINISHES. 12.IN ACCORDANCE WITH LOCAL CODES, REPLACE ALL FIRE SUPPRESSION AND FIRE ALARM EQUIPMENT DISTURBED BY DEMOLITION WORK. MAINTAIN INTEGRITY OF FIRE SUPPRESSION AND FIRE ALARM SYSTEMS. 13.IN THE CASE THAT THE EXISTING CABLE LINE, PHONE LINE AND BLOCK, T-1 LINE AND DATA CABLING ARE PRESENT, G.C. SHALL SALVAGE AND REWORK TO FACILITATE NEW INSTALLATION 14.G.C. SHALL CONSTRUCT A BARRICADE WALL AS REQUIRED. G.C. SHALL COORDINATE REQUIREMENTS WITH MALL PROPERTY MANAGEMENT. 15.BARRICADE GRAPHICS SHALL BE PROVIDED BY MALL UNLESS OTHERWISE REQUESTED. G.C. SHALL ENGAGE PACSUN'S SIGN VENDOR FOR BARRICADE GRAPHICS AS REQUIRED. 16.FIRE SPRINKLER SYSTEM TO REMAIN - G.C. TO RE-WORK/ MODIFY SYSTEM AS REQUIRED FOR NEW CONSTRUCTION. 17.WHERE REQUIRED BY THE LOCAL JURISDICTION, G.C. SHALL PREPARE A "RECYCLING PLAN" TO DIVERT DEBRIS FOR RECYCLING. G.C. SHALL KEEP RECORDS OF DIVERTED MATERIAL AS REQUIRED. G.C. TO VERIFY REQUIREMENTS WITH JURISDICTION AND TO MALL OPERATIONS/ LANDLORD WHERE APPLICABLE. 18.REMOVE ALL EXISTING INTERIOR PARTITIONS, DOORS, AND DOOR FRAMES SCHEDULED FOR DEMOLITION. REMOVE ALL MILLWORK, EQUIPMENT, ETC. THAT IS ATTACHED TO PARTITIONS SCHEDULED FOR DEMOLITION. 19.REMOVE EXISTING HVAC CEILING DIFFUSERS AND RETURN GRILLES AS SCHEDULED FOR DEMOLITION AND AS REQUIRED BY PARTITION DEMOLITION AND NEW CONSTRUCTION. MODIFY EXISTING DUCTWORK AS REQUIRED BY NEW CONSTRUCTION, OR IF NOT REQUIRED, TERMINATE AND CAP OFF SUPPLY AND RETURN DUCTS AT NEAREST SOURCE ABOVE CEILING. 20.REMOVE ALL EXISTING PLUMBING FIXTURES, FITTINGS, AND PIPING AS SCHEDULED FOR DEMOLITION AND AS REQUIRED BY PARTITION DEMOLITION AND NEW CONSTRUCTION. MODIFY EXISTING PIPING AS REQUIRED BY NEW CONSTRUCTION, OR IF NOT REQUIRED, TERMINATE AND CAP OFF AT WET STACK. 21.REMOVAL/RELOCATION OF ALL CEILING EQUIPMENT (TYCO, FIRE ALARM, SPRINKLER, SHOPPER TRAK, ETC.) MUST BE PERFORMED BY THE REQUIRED VENDORS. PACSUN'S VENDOR TO RELOCATE SECURITY CAMERAS AS NEEDED PER NEW FIXTURE LAYOUT. COORDINATE WITH PACSUN'S PROJECT MANAGER. 22.G.C. TO CONFIRM FLOOR SLAB IS SMOOTH AND LEVEL AND NOTIFY CONSTRUCTION PM OF ANY DISCREPANCIES. 23.MAINTAIN EXISTING EXITS, EMERGENCY LIGHTING, AND ILLUMINATION MEANS OF EGRESS DURING DEMOLITION AND CONSTRUCTION AS REQUIRED BY JHA AND ALL GOVERNING CODES. 24.SAW-CUTTING SHOWN ON PLANS IS AN INDICATION OF THE INTENDED WORK FOR BIDDING AND COORDINATION PURPOSES ONLY. IT IS NOT INTENDED TO BE A SPECIFICATION OR METHOD. 25.WHEN EXISTING MECHANICAL SYSTEM IS TO REMAIN, G.C. TO CLEAN DUCTWORK, DIFFUSERS, AND REPLACE HVAC AIR FILTERS AFTER CONSTRUCTION AND CLEANUP IS COMPLETE PRIOR TO TURNING PROJECT OVER TO PACSUN. 26.DURING CONSTRUCTION, THE G.C. IS TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A WITHIN 75 FOOT TRAVEL DISTANCE TO ALL PORTIONS OF THE SPACE. 1.GENERAL CONTRACTOR AND/OR SUBCONTRACTORS SHALL REVIEW THE EXISTING FACILITY TO DETERMINE THE EXTENT OF DEMOLITION REQUIRED TO INSTALL THE NEW WORK. A WRITTEN OUTLINE OF ALL REQUIRED DEMOLITION SHALL BE SUBMITTED TO THE PACSUN DESCRIBING THE FOLLOWING (BUT NOT LIMITED TO): 1.1.CONDITION OF EXISTING POWER PANELS AND TRANSFORMERS; FEASIBILITY FOR RELOCATION AND REFURBISHING, OR NEED FOR REPLACEMENT DUE TO AGE OR EXISTING CONDITION. 1.2.CONDITION OF EXISTING GYPSUM BOARD ON EXISTING DEMISING WALLS AND RECOMMENDATION OF WHETHER TO REMOVE EXISTING OR REUSE TO BE DETERMINED IN FIELD. 1.3.SUMMARIZE RECOMMENDATIONS FOR REUSE OF EXISTING MATERIALS, EQUIPMENT AND ACCESSORIES. ONCE REFURBISHED TO A LIKE-NEW CONDITION, ITEMIZE THE CREDIT TO THE CONTRACT. 1.4.TENANT G.C. SHALL NOTIFY ARCHITECT OF ANY UN-NOTED EXISTING CONDITION WHICH CONFLICTS WITH THE PROJECT REQUIREMENTS AND MAY REQUIRE MODIFICATION, RELOCATION, OR REMOVAL TO COMPLETE THE PROJECT WITHIN 24 HOURS SO THAT THE NECESSARY DRAWING REVISIONS MAY BE INCORPORATED INTO THE PROJECT REQUIREMENTS. 1.5.IN ADDITION TO THE ABOVE, REFER TO GENERAL DEMOLITION NOTES INDICATED IN SPECIFICATION DIVISION 2 - DEMOLITION / BUILDING ALTERATION. 1.6.CONDITION OF EXISTING MECHANICAL SYSTEM; FEASIBILITY OF REUSING, RELOCATION, OR REFURBISHING EXISTING EQUIPMENT AND DUCTWORK; AND RECOMMENDATION OF REPLACEMENT, IF NECESSARY, PRIOR TO BID. SEE MECHANICAL DRAWINGS FOR SCOPE OF MECHANICAL WORK 2.WHEN EXISTING CEILING IS TO REMAIN, REPLACE INDIVIDUAL CEILING TILES IF DAMAGED OR NOT MATCHED TO ADJACENT TILES. IF MORE THAN 25% ARE DAMAGED OR NOT MATCHED TO ADJACENT TILES, G.C. TO REPORT CONDITION AND COORDINATE EXTENT OF REPLACEMENT WITH CONSTRUCTION PM. GENERAL NOTESSCOPE SUMMARY 1 DEMOLITION REFLECTED CEILING PLAN 1/4" = 1'-0" LED-LC2-R-EMLED-LC2-R-EM SD C C SD S C S C SD C S SD S SD S C S SDSD SD C S SC C C LE D - E M E LE D - E M E LE D - E M E SD C S S C SD C SD S S SD C CCS C SD LED-EM SS S S SD S C SD SD LED-EME 1 1 1 2 2 ADJACENT TENANT ADJACENT TENANT MALL CORRIDOR 1 1 1 1 1 N 1 1 1 3 3 3 3 3 3 3 3 1 3 1 3 1 3 VOID H-12 SPACE H-13 SPACE H-14 SPACE A102 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 DEMOLITION REFLECTED CEILING PLAN (E ) V O I D EXISTING SIGNAGE 1 ENLARGED DOMLITION STOREFRONT PLAN 3/8" = 1'-0" FINISH FLOOR 0'-0" T.O. (E) BUILDING 15'-10" V.I.F. EXISTING LEASE LINE 31 ' - 5 " V . I . F . (E ) S T O R E F R O N T T O B E B E D E M O L I S H E D E N T I R E L Y 58'-1" V.I.F. (E) STOREFRONT TO BE DEMOLISHED ENTIRELY 1 A103 NOTES: REFER TO DEMOLITION PLAN FOR MORE PLAN DEMOLITION INFORMATION. EXISTING SIGNAGE EXISTING SIGNAGE (E) 5" V.I.F. (E ) 1' - 6 " V. I . F . (E) 8" V.I.F. (E ) A D J A C E N T T E N A N T (E) MALL 2 DEMOLITION STOREFRONT ELEVATION 3/8" = 1'-0" 3 A103 3 DEMOLITION STOREFRONT ELEVATION 3/8" = 1'-0" (E) H-12 SPACE(E) H-13 SPACE(E) H-14 SPACE FINISH FLOOR 0'-0" T.O. (E) BUILDING 15'-10" V.I.F. KEYED NOTES NOTES 1 REMOVE STOREFRONT SYSTEMS, GLAZING, AND DOORS IN THEIR ENTIRETY. 2 EXISTING DEMISING WALL TO REMAIN. PATCH AND REPAIR AS REQUIRED. 3 LEASE LINE 4 EXISTING FLOORING AND WALL TILE TO BE REMOVED PREPARE FOR INSTALLATION OF NEW FLOORING AND WALL MATERIALS AS INDICATED IN THESE PLANS. SEE SPECIFICATIONS FOR ADDITIONAL FLOOR PREPARATION NOTES. 5 EXISTING AUTO FIRE SYSTEM 4 TO BE REMOVED ENTIRELY. V.I.F. 6 EXISTING STRUCTURAL COLUMN TO REMAIN. 7 EXISTING CEILING, LIGHT FIXTURES, AND DIFFUSERS TO BE REMOVED IN THEIR ENTIRETY. 8 EXISTING FURRING TO REMAIN. PATCH AND REPAIR AS NEEDED. PREP FOR FINISHES. 9 EXISTING ADJACENT TENANT'S STOREFRONT TO REMAIN IN ITS ENTIRETY, N.I.S. 10 EXISTING INTERIOR WALL TO BE REMOVED IN ITS ENTIRETY. 11 EXISTING SIGNAGE AND CONNECTIONS TO BE REMOVED IN ITS ENTIRETY. ## 11 1 1 1 1 1 1 11 1 3 3 3 3 6 6 2 2 2 4 7 4 7 4 7 9 1515 8 10 10 1 1 2 2 1 1 1 2 1 1 1 2 3 3 11 11 11 3 1 1 1 11 5 GENERAL NOTES 1.CHECK MECHANICAL AND ELECTRICAL DRAWINGS PRIOR TO DEMOLITION WITH REGARD TO UTILIZING ANY EXISTING WIRING, LINES, COMPONENTS, ETC. 2.PROVIDE TRASH CONTAINER AS REQUIRED AT LOCATION TO SUIT LANDLORD. REMOVE DEBRIS DAILY AND HAUL FROM THE SITE AT TIME TO SUIT LANDLORD. 3.NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES OR UNFORESEEN ITEMS NOT SHOWN ON DRAWINGS. 4.ALL REMOVED MATERIAL AND DEBRIS, NOT OTHERWISE DESIGNATED, BECOMES THE PROPERTY OF THE CONTRACTOR, WHO SHALL REMOVE IT FROM THE SITE. 5.G.C. SHALL NOT DEMOLISH ANY LOAD BEARING WALLS OR CONSTRUCTION THAT WILL COMPROMISE THE STRUCTURAL INTEGRITY OF THE EXISTING SPACE. G.C. TO NOTIFY THE ARCHITECT IMMEDIATELY OF ANY STRUCTURAL CONCERNS DURING DEMOLITION. 6.EXISTING EQUIPMENT NOT BEING USED MUST BE COMPLETELY REMOVED / DISPOSED OF PROPERLY. NOTHING CAN BE ABANDONED ABOVE THE CEILING. 7.REMOVE EXISTING ACOUSTICAL CEILING GRID AND TILES, LIGHT FIXTURES, AND GYPSUM WALLBOARD SOFFITS AS SCHEDULED FOR DEMOLITION AND AS REQUIRED BY PARTITION DEMOLITION AND NEW CONSTRUCTION WORK. MAINTAIN EXISTING CEILING WIRE HANGERS FOR FUTURE USE. 8.REMOVE EXISTING ELECTRICAL DEVICES, OUTLETS, TELEPHONE AND DATA JACKS AND THERMOSTATS IN PARTITIONS SCHEDULED FOR DEMOLITION. MODIFY EXISTING WIRING AS REQUIRED BY NEW CONSTRUCTION OR, IF NOT REQUIRED, TERMINATE AND CAP OFF AT NEAREST PANEL OR SOURCE ABOVE CEILING. 9.REMOVE EXISTING FLOOR FINISHES SCHEDULED FOR REMOVAL AND AS REQUIRED BY PARTITION DEMOLITION AND NEW CONSTRUCTION. PREPARE EXISTING FLOOR SURFACE PER MANUFACTURER FOR INSTALLATION OF NEW FLOORING MATERIAL AS INDICATED IN THESE PLANS. G.C. MAY NEED TO PERFORM A MOISTURE TEST PRIOR TO ANY DEMOLITION OR NEW FLOORING INSTALLATION. NEWLY REPLACED OR LIKE-NEW FINISHES MAY REMAIN AT THE DISCRETION OF THE CONSTRUCTION PM. G.C. TO VERIFY PRIOR TO REMOVAL. PROTECT ALL NEW FLOOR FINISHES UNTIL FINAL CLEANING. 10.REMOVE ALL CONSTRUCTION DEBRIS FROM AREA. REPAIR ALL ADJACENT DAMAGED SURFACES, AS NECESSARY. PREPARE ALL DAMAGED SURFACES FOR FINISHES AS SCHEDULED OR REFINISH TO MATCH EXISTING FINISH. 11.PROVIDE A SMOOTH, NEAT, AND CONTINUOUS APPEARANCE WHERE DEMOLITION WORK MEETS ADJACENT EXISTING WORK. REMOVE EXISTING FINISHES AS REQUIRED TO PROVIDE NEAT, STRAIGHT SEAMS AND TRANSITIONS BETWEEN EXISTING AND MATCHING NEW FINISHES. 12.IN ACCORDANCE WITH LOCAL CODES, REPLACE ALL FIRE SUPPRESSION AND FIRE ALARM EQUIPMENT DISTURBED BY DEMOLITION WORK. MAINTAIN INTEGRITY OF FIRE SUPPRESSION AND FIRE ALARM SYSTEMS. 13.IN THE CASE THAT THE EXISTING CABLE LINE, PHONE LINE AND BLOCK, T-1 LINE AND DATA CABLING ARE PRESENT, G.C. SHALL SALVAGE AND REWORK TO FACILITATE NEW INSTALLATION 14.G.C. SHALL CONSTRUCT A BARRICADE WALL AS REQUIRED. G.C. SHALL COORDINATE REQUIREMENTS WITH MALL PROPERTY MANAGEMENT. 15.BARRICADE GRAPHICS SHALL BE PROVIDED BY MALL UNLESS OTHERWISE REQUESTED. G.C. SHALL ENGAGE PACSUN'S SIGN VENDOR FOR BARRICADE GRAPHICS AS REQUIRED. 16.FIRE SPRINKLER SYSTEM TO REMAIN - G.C. TO RE-WORK/ MODIFY SYSTEM AS REQUIRED FOR NEW CONSTRUCTION. 17.WHERE REQUIRED BY THE LOCAL JURISDICTION, G.C. SHALL PREPARE A "RECYCLING PLAN" TO DIVERT DEBRIS FOR RECYCLING. G.C. SHALL KEEP RECORDS OF DIVERTED MATERIAL AS REQUIRED. G.C. TO VERIFY REQUIREMENTS WITH JURISDICTION AND TO MALL OPERATIONS/ LANDLORD WHERE APPLICABLE. 18.REMOVE ALL EXISTING INTERIOR PARTITIONS, DOORS, AND DOOR FRAMES SCHEDULED FOR DEMOLITION. REMOVE ALL MILLWORK, EQUIPMENT, ETC. THAT IS ATTACHED TO PARTITIONS SCHEDULED FOR DEMOLITION. 19.REMOVE EXISTING HVAC CEILING DIFFUSERS AND RETURN GRILLES AS SCHEDULED FOR DEMOLITION AND AS REQUIRED BY PARTITION DEMOLITION AND NEW CONSTRUCTION. MODIFY EXISTING DUCTWORK AS REQUIRED BY NEW CONSTRUCTION, OR IF NOT REQUIRED, TERMINATE AND CAP OFF SUPPLY AND RETURN DUCTS AT NEAREST SOURCE ABOVE CEILING. 20.REMOVE ALL EXISTING PLUMBING FIXTURES, FITTINGS, AND PIPING AS SCHEDULED FOR DEMOLITION AND AS REQUIRED BY PARTITION DEMOLITION AND NEW CONSTRUCTION. MODIFY EXISTING PIPING AS REQUIRED BY NEW CONSTRUCTION, OR IF NOT REQUIRED, TERMINATE AND CAP OFF AT WET STACK. 21.REMOVAL/RELOCATION OF ALL CEILING EQUIPMENT (TYCO, FIRE ALARM, SPRINKLER, SHOPPER TRAK, ETC.) MUST BE PERFORMED BY THE REQUIRED VENDORS. PACSUN'S VENDOR TO RELOCATE SECURITY CAMERAS AS NEEDED PER NEW FIXTURE LAYOUT. COORDINATE WITH PACSUN'S PROJECT MANAGER. 22.G.C. TO CONFIRM FLOOR SLAB IS SMOOTH AND LEVEL AND NOTIFY CONSTRUCTION PM OF ANY DISCREPANCIES. 23.MAINTAIN EXISTING EXITS, EMERGENCY LIGHTING, AND ILLUMINATION MEANS OF EGRESS DURING DEMOLITION AND CONSTRUCTION AS REQUIRED BY JHA AND ALL GOVERNING CODES. 24.SAW-CUTTING SHOWN ON PLANS IS AN INDICATION OF THE INTENDED WORK FOR BIDDING AND COORDINATION PURPOSES ONLY. IT IS NOT INTENDED TO BE A SPECIFICATION OR METHOD. 25.WHEN EXISTING MECHANICAL SYSTEM IS TO REMAIN, G.C. TO CLEAN DUCTWORK, DIFFUSERS, AND REPLACE HVAC AIR FILTERS AFTER CONSTRUCTION AND CLEANUP IS COMPLETE PRIOR TO TURNING PROJECT OVER TO PACSUN. 26.DURING CONSTRUCTION, THE G.C. IS TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A WITHIN 75 FOOT TRAVEL DISTANCE TO ALL PORTIONS OF THE SPACE. A103 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 DEMOLITION ENLARGED STOREFRONT PLAN AND ELEVATIONS ACCESSIBILITY COMPLIANCE NOTES 1.I AM THE DESIGNER/OWNER IN RESPONSIBLE CHARGE OF THIS TENANT IMPROVEMENT PROJECT. I HAVE INSPECTED THE SITE/PREMISES AND DETERMINED THAT EXISTING CONDITIONS ARE IN FULL COMPLIANCE WITH CURRENT SITE ACCESSIBILITY REQUIREMENTS TO THE EXTENT REQUIRED BY LAW. PRINT NAME: ___________________, SIGNATURE: _________________________ , DATE: ___________________. 2.I AM THE DESIGNER/OWNER IN RESPONSIBLE CHARGE OF THIS TENANT IMPROVEMENT PROJECT. I HAVE INSPECTED THE TOILET AND BATHING FACILITIES FOR MEN AND WOMEN, AND DETERMINED THAT EXISTING CONDITIONS ARE IN FULL COMPLIANCE WITH CURRENT ACCESSIBILITY REQUIREMENTS TO THE EXTENT REQUIRED BY LAW. PRINT NAME: ___________________, SIGNATURE: _________________________ , DATE: ___________________. 3.IF THE CITY BUILDING INSPECTOR DETERMINES NON-COMPLIANCE WITH ANY ACCESSIBILITY PROVISIONS, A COMPLETE AND DETAILED REVISED PLANS CLEARLY SHOWING ALL EXISTING NON-COMPLYING CONDITIONS AND THE PROPOSED MODIFICATIONS TO MEET CURRENT ACCESSIBILITY REQUIREMENTS (INCLUDING SITE PLAN, FLOOR PLANS, DETAILS, ETC.) WILL BE SUBMITTED TO THE DEPARTMENT FOR REVIEW AND APPROVAL. PRINT NAME: ___________________, SIGNATURE: _________________________ , DATE: ___________________. PROJECT DATA BUILDING ADDRESS: 400 SOUTH BALDWIN AVENUE, ARCADIA, CALIFORNIA 91007 COUNTY LOS ANGELES MUNICIPALITY ARCADIA ASSESSOR PARCEL NUMBER: 5775031040 LEGAL DESCRIPTION: P M 261-91-95 FOR DESC SEE ASSESSOR'S MAPS POR OF LOT 2 SCHOOL DISTRICT: ARCADIA UNIFIED SCHOOL DISTRICT 1 ARCHITECTURAL SITE PLAN 1/128" = 1'-0"N H U N T I N G T O N D R I V E H U N T I N G T O N B O U L E V A R D BALDWIN AVE N U E GAT E 8 58 9 ' - 1 0 " T O P U B L I C R E S T R O O M PERFECT AUTO 6,232 SF 589'-10" PATH OF TRAVEL TO PUBLIC RESTROOM FROM STORE MALL PROPERTY LINE NEAREST PUBLIC RESTROOM INCLUDES: -MEN'S RESTROOM (3) LAVATORIES (3) TOILET STALLS (3) URINALS -WOMEN'S RESTROOM (4) LAVATORIES (6) TOILET STALLS -FAMILY RESTROOM (3) LAVATORIES (1) TOILET STALLS AREA OF TENANT IMPROVEMENT SPACE #H-13, H-14 AND H-15 LEVEL 2 OF 3 LOCATION OF LOADING DOCK 4 (TRASH / RECYCLING AREA): HEIGHT: OPEN AIR WIDTH: 37'-0" LENGTH: 42'-0" EXISTING ADA COMPLIANT PARKING STALLS AND ADA LOCATIONS A110 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 SITE PLAN (E) VOID 1.G.C. TO FIELD VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES OR UNFORESEEN ITEMS NOT SHOWN ON DRAWINGS. 2.FOR ALL PARTITION CONNECTION DETAILS (TOP AND BOTTOM) SEE SHEET A531. 3.ALL ANGLED WALLS ARE 45°, 90°, OR 135° U.O.N. 4.MAINTAIN FIRE RESISTANCE RATING FOR ALL TENANT DEMISING WALLS. 5.PROVIDE WATER RESISTANT GYPSUM BOARD AT ALL WET LOCATIONS (UTILITY SINK, KITCHENETTE, DRINKING FOUNTAIN, TOILET ROOM, ETC.) 6.G.C. TO COORDINATE LOCATION OF ELECTRICAL FLOOR BOXES WITH ELECTRICAL DRAWINGS AND FIXTURE PLAN. 7.WHERE EXISTING INSULATION IS REMOVED OR MISSING, PATCH AND REPLACE INSULATION TO MATCH EXISTING CONDITIONS AND MAINTAIN REQUIRED R-VALUES. 8.ALL DOORS TO BE LOCATED 4" FROM PERPENDICULAR WALL UNLESS OTHERWISE NOTED. ALL DOORS DIMENSIONED TO ROUGH OPENING OF DOOR. 9.ALL DIMENSIONS ARE FROM FACE OF GYPSUM BOARD TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. 10.SLAB PENETRATIONS SHALL BE MADE WITH PROPER LOCATION AND X-RAY IDENTIFICATION OF EXISTING REBAR AND/OR POST TENSION CABLES. 107'-10" V.I.F. LEASE LINE GENERAL NOTES 1 CONSTRUCTION FLOOR PLAN 1/4" = 1'-0" NEW FIRE EXTINGUISHER CABINET DETAIL SYMBOL ROOM NAME SYMBOL ELEVATION SYMBOL DOOR/FRAME TYPE HARDWARE TYPE FEC EXISTING FIRE EXTINGUISHER CABINET(E) FEC RELOCATED FIRE EXTINGUISHER CABINET(R) FEC EXISTING WALLS NEW WALLS AS SCHEDULED RELOCATED EXISTING NEW R E N WALL TYPE NOTE: ·REFER TO SHEET A611 FOR DOOR , HARDWARE, AND PARTITION INFORMATION. ·DIMENSIONS FOR REFERENCE ONLY, TENANT G.C. TO COORDINATE WITH FIELD CONDITIONS AND COORDINATE ANY FIELD DISCREPANCIES WITH DESIGNER PRIOR TO CONSTRUCTION. ELECTRICAL FLOOR BOX NEW DOOR AS SCHEDULED NEW WALL EXISTING WALL FE FIRE EXTINGUISHER SALES AREA STOCK ROOM HALLWAY FITTING ROOM HALLWAY 4'-0"5'-1" NEW STOREFRONT AND WINDOW SYSTEM, TYP. EXISTING EXIT DOORS 2 B TENANT G.C. IS RESPONSIBLE TO MEASURE (VERIFY) OVERALL DIMENSIONS, COLUMN SIZE & LOCATIONS, BULKHEAD HEIGHT, ETC. OF SPACE AFTER DEMOLITION (ALSO CONFIRM CEILING CLEARANCES AND LOOK FOR ANY OTHER POTENTIAL OBSTRUCTIONS). IF FIELD DIMENSIONS VARY BY ANY AMOUNT FROM THE DIMENSIONS NOTED IN THIS SET OF CONSTRUCTION DOCUMENTS, THE CONTRACTOR SHALL NOT CONTINUE FRAMING LAYOUT UNTIL DIRECTED BY TENANT (CONTRACTOR SHALL NOTIFY TENANT'S CONSTRUCTION MANAGER IMMEDIATELY IN WRITING OF ANY DIMENSION DISCREPANCIES OR BUILDOUT OBSTRUCTIONS). IF OVERALL DIMENSIONS OF SPACE MATCH THIS SET OF CONSTRUCTION DOCUMENTS, THE CONTRACTOR SHALL BEGIN FRAMING LAYOUT BY SNAPPING CHALKLINES OF ALL WALL LOCATIONS BEFORE BEGINNING TO SECURE TRACK. SEE PLAN ABOVE FOR LAYOUT START POINT. IF LAYOUT START POINT IS NOT INDICATED ON PLANS, TENANT G.C. SHALL CALL ARCHITECT IMMEDIATELY AND TO OBTAIN START POINT IN WRITING. ALL SALES AREA AND FITTING ROOM DIMENSIONS ARE HOLD DIMENSIONS AND SHALL NOT BE ADJUSTED ON SITE UNLESS DIRECTED BY TENANT IN WRITING. IF FRAMING CONTRACTOR DOES NOT FOLLOW THESE PROCEDURES, ANY REQUIRED REWORK THAT IS CONSIDERED AVOIDABLE SHALL BE DONE BY TENANT G.C. AT TENANT G.C.'S EXPENSE. FRAMING LAYOUT START POINT NOTE IN-WALL BLOCKING NOTE ALL IN-WALL BLOCKING SHALL BE IN ACCORDANCE WITH BUILDING CODES (REFER TO CONSTRUCTION CLASSIFICATION ON COVER SHEET THIS SET). - F.R.T. WOOD BLOCKING MAY BE USED FOR (1) HOUR F.R. CONSTRUCTION TYPES AND TYPE IV AND TYPE V CONSTRUCTION TYPES AS PERMITTED BY LOCAL A.H.J. - F.R.T. WOOD BLOCKING IS NOT APPROVED IN TYPE I AND TYPE II-A AND NON-COMBUSTIBLE CONSTRUCTION TYPES. ALL IN-WALL BLOCKING IN THESE CONSTRUCTION TYPES SHALL BE 18GA. METAL (MINIMUM 6" WIDE AND SHALL SPAN MINIMUM 2 STUDS). 13 ' - 6 " UN I S E X A D A FI T T I N G R O O M NEW FURR-OUT WALL W/ STUDS 24" O.C. COORDINATE STUDS SPACING WITH SURFACE MOUNTED OUTRIGGER STANDARDS. T.G.C. SHALL CONSULT W/OWNER FOR STRUCTURAL CONNECTION OF WALL STANDARDS TO EXISTING MASONRY WALLS, TYP. WOMEN'S TOILET ROOM MALL CORRIDOR ADJACENT TENANT MEN'S TOILET ROOM 1 A401 1 A402 B CA A 47 ' - 9 1 / 2 " LE A S E L I N E UNISEX FITTING ROOMS 4'-0"4'-0"4'-0"5'-0" 28'-2" 2' - 0 " HO L D CA A NEW FURR-OUT WALL W/ STUDS 24" O.C. COORDINATE STUDS SPACING WITH SURFACE MOUNTED OUTRIGGERS. T.G.C. SHALL CONSULT W/OWNER FOR CONNECTION OF WALL OUTRIGGERS TO EXISTING MASONRY WALLS WHERE IT OCCURS, TYP. 3'-0" HOLD 8 D 4 G F 6 C 3 C 3 K7 D 8 B1 B A1 B1 B1B3 B1 B1 A A A1 35 ' - 7 1 / 2 " 17 ' - 1 " 3' - 0 " 7' - 1 1 " 2'-0" 2' - 0 " C1 B2 2'- 1 " C C 5'-0" 5' - 1 " 5' - 0 " CL R . 5' - 1 " T Y P . B2 F 6 3 A401 NEW STRUCTURAL COLUMN, TYP. REFER TO STRUCTURAL DRAWINGS E N C A C CA CA A B1 C C C C B2 B1 TYP. TYP. TYP. B1 B1 NEW FURR-OUT WALL W/ STUDS 24" O.C. COORDINATE STUDS SPACING WITH SURFACE MOUNTED OUTRIGGERS. T.G.C. SHALL CONSULT W/OWNER FOR CONNECTION OF WALL OUTRIGGERS TO EXISTING MASONRY WALLS WHERE IT OCCURS. ADJACENT TENANT EXISTING DOOR TO BE WELDED IN THE CLOSED AND LOCKED POSITION. NEW FURR-OUT WALL AS INDICATED IN THESE PLANS. EXISTING DOOR TO BE WELDED IN THE CLOSED AND LOCKED POSITION. NEW FURR-OUT WALL AS INDICATED IN THESE PLANS. 20 ' - 9 1 / 2 " 7'- 6 " 25'-5 1/2" 9'-5" 5' - 0 " CL R . TYP.A1 E E (E) COLUMN AND BUILD-OUT.(E) COLUMN (E) COLUMN WITH NEW FURRING. NEW STOREFRONT AND WINDOW SYSTEM, TYP. 16' - 5 1 / 2 " OP E N I N G 2'- 1 1 " 3'- 0 " 22 ' - 1 1 / 2 " 3'-2 " EXISTING DOOR AS SCHEDULED 7'-3"2'-10" 77'-5 1/2" LEASE LINE 1'-4" 1' - 4 " 2'-5 " 2'-5 " F 6 F 6 F 6 F 6 F 6 F 6 F 6 E 4 A 1 1.REMOVAL OR ADDITION OF INTERIOR WALLS SHALL REQUIRE A PERMIT FROM THE ARCADIA BUILDING DIVISION, (626) 574-5448. 2.A BUSINESS LICENSE SHALL BE OBTAINED FROM THE BUSINESS LICENSE OFFICE, (626) 574-5430. 3.MINIMUM RATED 2A:10BC FIRE EXTINGUISHERS SHALL BE PROVIDED IN APPROVED LOCATIONS. THE TRAVEL DISTANCE TO AN EXTINGUISHER SHALL NOT EXCEED 75 FEET. 4.A KNOX BOX SHALL BE PROVIDED ADJACENT TO THE FRONT ENTRANCE AND MOUNTED NO HIGHER THAN 18 INCHES A.F.F. KEYS TO THE FRONT ENTRANCE SHALL BE PROVIDED TO THE FIRE DEPARTMENT AND PLACED IN THE KNOX BOX FOR EMERGENCY USE ONLY. 5.ANY MODIFICATIONS TO THE FIRE SPRINKLER OR FIRE ALARM SYSTEM SHALL REQUIRE A SEPARATE PERMIT. MODIFICATION TO AN EXISTING SPACE REQUIRING A BUILDING PERMIT SHALL ALSO REQUIRE FULL SMOKE DETECTION FOR THE SPACE. 6.FOR NEW OR TEMPORARY TENANTS, ANY EXISTING SMOKE AND/OR HEAT DETECTORS IN THE SPACE SHALL BE REPROGRAMMED TO REFLECT THE NEW TENANCY. CONTACT THE MALL FIRE ALARM CONTRACTOR TO CONDUCT THE PROPER PROGRAMMING. 7.ALL REQUIRED EXIT SIGNAGE AND EMERGENCY LIGHTING SHALL BE FUNCTIONING PROPERLY. 8.EXIT PATHS SHALL BE KEPT CLEAR AT ALL TIMES, INCLUDING REAR HALLWAYS AND CORRIDORS. ALL EXIT DOORS SHALL BE EASILY OPENED. ANY LOCKING DEVICES SHALL REQUIRE ONLY ONE ACTION AND NO SPECIAL KNOWLEDGE TO OPERATE. 9.THERE SHALL BE A MINIMUM CLEAR SPACE OF 36” IN FRONT OF ELECTRICAL PANELS AND TRANSFORMERS. ELECTRICAL ROOMS SHALL BE KEPT CLEAR OF STORAGE. LANDLORD REQUIREMENT NOTES SHEET SYMBOLS NAME # A### X# X### X# X###SECTION SYMBOL ELECTRICAL OUTLET E 5' - 1 1 " 3' - 6 " 13'-3"5'-1" 11'-1 1/2"8'-0" 1' - 6 " 8' - 4 " 5'-4 1/2" 22'-8" B 8'-0" 16'-7" 4' - 3 1 / 2 " 5'-6"61'-6" 2' - 0 " V. I . F . 38'-0" NEW STRUCTURAL COLUMNS, TYP. REFER TO STRUCTURAL DRAWINGS ALIGN 8" 14 ' - 9 " 5"V. I . F . 11" NEW STRUCTURAL COLUMNS, TYP. REFER TO STRUCTURAL DRAWINGS NEW STRUCTURAL COLUMNS, TYP. REFER TO STRUCTURAL DRAWINGS NEW STRUCTURAL COLUMNS, TYP. NEW STRUCTURAL COLUMNS, TYP. REFER TO STRUCTURAL DRAWINGS 5 A303 9 A303 9 A303 13 A303 TYP. 11" 11" 9'-0 " T Y P . 2'-4 " 2'-4 " 6'-7 " 3 A303 TYP. 16 ' - 2 1 / 2 " LE A S E L I N E 5'-5" 8" 2'-11" LINE OF MALL HEADER LINE OF NEW STOREFRONT SOFFIT LINE OF MALL HEADER LINE OF NEW STOREFRONT SOFFIT MALL MALL J10 NEW RATED EGRESS DOOR TO MATCH EXISTING WITH PANIC PUSH HARDWARE - COORDIANTE WITH LANDLORD. 3' - 1 1 " 1'- 6 " A111 CONSTRUCTION FLOOR PLAN ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 2 2 2 WALL FINISH BASE FINISH FLOOR FINISH EXISTING AREA N.I.C. 1.SEE SHEET A505 FOR FLOOR TRANSITION AND BASE DETAILS. 2.PREPARE EXISTING FLOOR SURFACE PER MANUFACTURER SPECIFICATIONS FOR INSTALLATION OF NEW FLOORING MATERIALS AS INDICATED IN THESE PLANS. SEE SPECIFICATIONS AND MANUFACTURER INSTRUCTIONS FOR ADDITIONAL FLOOR INSTALLATION NOTES. CLEAN AND FINISH FLOOR PER MANUFACTURER INSTRUCTIONS. 3.FOR FLOOR FINISHES, COMPLY WITH THESE RECOMMENDATIONS AT MINIMUM OR NOT LESS THAN MANUFACTURER'S WRITTEN INSTRUCTIONS. REFER TO MANUFACTURER'S INSTALLATION SPECIFICATIONS FOR ALL FINISHES INCLUDING FLOOR LEVELING REQUIREMENTS, EXPANSION SPACES, VAPOR BARRIERS, UNDERLAYMENT, SITE CONDITIONS, ETC. 3.1.SUBFLOOR PREPARATION: GRIND HIGH SPOTS AND FILL LOW SPOTS TO PRODUCE A MAXIMUM 1/8” (3-MM) DEVIATION IN ANY DIRECTION WHEN CHECKED WITH A 10' (3-M) STRAIGHT EDGE 3.2.EXPANSION: PROVIDE EXPANSION SPACE AT WALLS AND OTHER OBSTRUCTIONS AND TERMINATIONS OF FLOORING OF NOT LESS THAN DIRECTED BY MANUFACTURER. 3.3.PROTECTION: PROVIDE FLOOR PROTECTION UP UNTIL FINAL CLEANING. GENERAL NOTESSHEET SYMBOLS F B W X### X### X### 1 FINISH PLAN 1/4" = 1'-0" ROOM FINISH TAG SALES AREA STOCK ROOM WOMAN'S TOILET ROOM FITTING ROOM HALLWAY CORRIDOR ADJACENT TENANT F B W ST-1 B-2 PT-3 UNISEX FITTING ROOMSUNISEX ADA FITTING ROOM F B W ST-2 B-4 PT-1 F B W VCT B-3 SEE ELEV. 7 A505 3 A505 F B W ST-1 B-1 PT-1 VCT-1 ST-1 MEN'S TOILET ROOM F B W VCT B-3 SEE ELEV. ADJACENT TENANT MALL 3 A505 2 A505 8 A505 8 A505 N NEW STRUCTURAL COLUMN TO BE PAINTED PT-1. WALLS TO BE PAINTED PT-1, WITH BASE B-1,TYP. (E) COLUMN FUR OUT TO BE PAINTED PT-1, WITH BASE B-1,TYP. (E) COLUMN FUR OUT TO BE PAINTED PT-1, WITH BASE B-1,TYP. (E) COLUMN TO BE PAINTED PT-1. F B W ST-1 B-2 PT-3 F B W ST-1 B-2 PT-3 HALLWAYS F B W ST-1 B-1 PT-1 NEW STRUCTURAL COLUMNS TO BE PAINTED PT-1, TYP. NEW STRUCTURAL COLUMNS TO BE PAINTED PT-1, TYP. WALLS TO BE PAINTED PT-1, WITH BASE B-1, TYP. WALLS TO BE PAINTED PT-1, WITH BASE B-1,TYP. EXTERIOR WALLS TO BE PREPPED FOR STOREFRONT SF-1 FINISH. REFER TO EXTERIOR ELEVATIONS AND FINISH SCHEDULE, TYP. REFER TO EXTERIOR ELEVATIONS FOR FINISH MATERIAL, TYP. ST-2 EXISTING NEUTRAL PIER TO BE PAINTED PT-6 PER MALL REQUIREMENT, TYP. PATCH AND REPAIR EXISTING MALL FLOORING, AS NEEDED, TYP. EXISTING NEUTRAL PIER TO BE PAINTED PT-6 PER MALL REQUIREMENT, TYP. EXTERIOR WALLS TO BE PREPPED FOR STOREFRONT SF-1 FINISH. REFER TO EXTERIOR ELEVATIONS AND FINISH SCHEDULE, TYP. (E) VOID LEASE LINE, TYP. LEASE LINE, TYP. NEW STRUCTURAL COLUMN FURRING TO BE PAINTED PT-1, WITH BASE B-1,TYP. NEW STRUCTURAL COLUMN FURRING TO BE PAINTED PT-1, WITH BASE B-1,TYP. WALLS TO BE PAINTED PT-1, WITH BASE B-1, TYP. A121 FINISH FLOOR PLAN ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 L-9 L-1S L-1S L-1S L-1S L-1S L-9 L-9 L-9L-9L-9 L-9 L-9 L-9 L-9L-9 L-6S L-6S L-6S L-6 L-6L-4 L-4L-4L-4 L-5 L-5 L-5 L-5 L-5 L-5L-5L-5L-5 L-5 L-5 L-7L-7L-7 L-7 L-7L-7 L-7L-7 L-7 L-7 L-1 L-1 L-6 L-10 L-10 L-10 L-10 L-10 L-10 1.G.C. TO VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES OR UNFORESEEN ITEMS NOT SHOWN ON DRAWINGS, INCLUDING CEILING HEIGHT. 2.UNLESS OTHERWISE NOTED ON PLANS, ALL CEILING EQUIPMENT SHOULD FOLLOW THE LAYOUT GUIDE ON THIS SHEET. 3.G.C. SHALL FIELD VERIFY EXISTING EGRESS LIGHTING AND PROVIDE NEW EMERGENCY LIGHT FIXTURES AS REQUIRED BY FIRE MARSHAL. 4.REFER TO MECHANICAL DRAWINGS FOR FURTHER INFORMATION ON SCOPE AND LOCATION OF MECHANICAL ITEMS 5.REFER TO VENDOR INSTALLATION GUIDE AND MANUFACTURER INSTRUCTIONS FOR FIXTURE INSTALLATION. 6.REFER TO ELECTRICAL DRAWINGS FOR FIXTURE TYPES AND LIGHT FIXTURE SCHEDULE. 7.NOTHING IS PERMITTED TO BE ATTACHED TO, SUSPENDED FROM, OR PENETRATE LANDLORD’S STRUCTURE, FLOOR DECK, OR ROOF DECK. YOU MAY ATTACH, NON-DESTRUCTIVELY, TO OR SUSPEND FROM THE TOP CHORD OF THE JOIST OR THE STRUCTURAL STEEL WHICH EXISTS ABOVE THE TENANT SPACE. WHEN ATTACHING TO LANDLORD’S STRUCTURE, DO NOT DRILL, WELD, SCREW, OR SHOOT INTO STRUCTURE. ALTERNATIVE METHODS OF ATTACHMENT ONLY, NOTHING TO DAMAGE LANDLORD’S BASE BUILDING STRUCTURE. TENANT SHALL PROVIDE SIGNED AND SEALED STRUCTURAL DRAWINGS, BY A STRUCTURAL ENGINEER WITH LEGALLY ACTIVE REGISTRATION AS INDICATED BY ALL JURISDICTIONAL REQUIREMENTS, FOR ALL STRUCTURAL MODIFICATIONS FOR LANDLORD RECORDS. GENERAL NOTESSHEET SYMBOLS GYP BOARD CEILING CEILING TYPE CEILING FINISH CEILING HEIGHT 2' X 4' LIGHT EXIT SIGNAGE T F H X### X### XX'-XX" 1 REFLECTED CEILING PLAN 1/4" = 1'-0" CEILING - LAY IN TILE RECESSED LIGHT LIGHTING FIXTURES SPECS L1 Item: LED LINEAR LIGHT Manufacturer: CORNET Finish: WHITE Size: 8' L-2 NOT USED L-3 NOT USED L-4 Item: PENDANT MOUNT LIGHT Mfg.: SONNEMAN LIGHT Product: KOMA TAISHO Finish: STAIN WHITE L-5 NOT USED L-6 Item: ASYMMETRIC WALL WASHER Mfg.: CORONET Finish:WHITE Size: 8' L-7 Item: RECESSED LIGHT Mfg: LUMENTURE Product : 2" FIXED DOWNLIGHT Product # : DL60 L-8 NOT USED L-9 Item: Suspended Light Mfg:VALRIYA Product : HPL SERIES Product # : VA-HPL-40-35 L-10 Item: Exit Light Mfg:TBD Product : TBD ADA UNISEX FITTING ROOM T F H PT-1 OPEN - SALES AREA T F H PT-1 OPEN (E) 20'-0" T F H PT-1 GYP 9'-0" MEN'S TOILET ROOM EQ EQ EQEQ LINEAR LIGHT SUSPENDED LIGHT EQ EQ MALL T F H PT-1 GYP 9'-0" WOMEN'S TOILET ROOM CORRIDOR ADJACENT TENANT ADJACENT TENANT EQEQEQ EQ EQ EQ EQ T F H PT-1 GYP 9'-0" EQEQ EQ EQ EQ EQ 8' - 4 " 2'-0 3/4" 6'-0" 8' - 4 " 6' - 2 " 4' - 7 1 / 4 " 6'-4"2'-2" 6'-0" 6'-0 1/2" 46 ' - 4 1 / 4 " 58'-5 3/4" EQ EQ EQ EQ 6' - 1 " 6' - 1 " 42'-10 1/4"4'-4 1/2" 38'-5 3/4"4'-4 1/2" 34'-1"4'-4 1/2" 29'-8 1/2"4'-4 1/2" 29'-8 1/2"5'-0" 4'-6" 4' - 8 " 4' - 8 " T F H PT-1 OPEN - STORAGE ROOM LIT STOREFRONT SIGN, PROVIDE ELECTRICAL. SEE ELECTRICAL PLANS OPEN CEILING - ALL EXPOSED PLUMBING, STRUCTURAL AND ELEMENTS TO BE PAINTED PT-1 OPEN CEILING - ALL EXPOSED PLUMBING, STRUCTURAL, MECHANICAL AND ELEMENTS TO BE PAINTED PT-1 34'-9 3/4" LINE OF MALL BULKHEAD UNISEX FITTING ROOM T F H PT-1 OPEN - FITTING ROOM HALLWAY T F H PT-1 OPEN - EQEQEQEQ EQEQ EQEQEQEQEQEQEQ 1 A301 EMERGENCY EXIT LIGHTS TO BE MOUNTED @ 9'-0" TYP. N LINE OF SOFFIT 2'-1 3/4" 6"6" 2 A301 2'- 9 " 8" TY P . 7" 4'-6 3 / 4 " 4'-6 3 / 4 " 2'-0 3/4" 2'-7 3/4" 4'- 7 1 / 4 " 2' - 9 1 / 4 " HALLWAY T F H PT-1 GYP. 10'-0" SOFFIT T F H PT-1 OPEN (E) 14'-4" 2'-4 1/2"5'-7 3/4"1'-6"6'-6" 4'-0" 3'- 6 " EQ. TYP. EQ. TYP. 10 A504 3 A504 TYP. 3 A504 TYP. 1'-1 1 " 7 A504 7 A504 7 A504 SIM. SIM. 6" 6" SECURITY GRILLE PER PLANS. 8 A504 8 A504 8 A504 SIM.SIM. (E) VOID SOFFIT STRUCTURAL BEAMS,TYP. REFER TO STRUCTURAL. CL G . S L O P E D I R E C T I O N 6" 6" 10'- 0 " 8" 8" 6" 7" 7" 1 A302 2 A302 1'-3 " ℄ LINE OF MALL BULKHEAD LINE OF SOFFIT 2'-0 1/2" 1'-10" A131 REFLECTED CEILING PLAN ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 2 2 MW FRIDGE DSL LOCKERS HA R D W A R E B I N 24x48 24x48 LA D D E R S TRANSFORMER BA R B I N PR O C E S S I N G D E S K +4 2 " A . F . F . 24x48 24x48 24x48 24x48 24x48 24x48 EXISTING AREA N.I.C. SHEET SYMBOLS FIXTURE TAG LINETYPE INDICATES ACCESSIBLE CLEARANCE GENERAL NOTES 1.G.C. TO FIELD VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES OR UNFORESEEN ITEMS NOT SHOWN ON DRAWINGS. 2.G.C. TO VERIFY THAT ADA COUNTERTOPS COMPLY WITH C1/G002 3.FIXTURES FURNISHED BY PACSUN AND PLACED BY G.C. OR FIXTURE VENDOR. 4.G.C. TO COORDINATE FLOOR POWER WITH ELECTRICAL SHEETS AND FIXTURE PLAN. 5.RELOCATE ALL THERMOSTATS AND OTHER WALL MOUNTED DEVICES AS PER LOCAL CODE AS REQUIRED PER NEW FIXTURE LAYOUT. COORDINATE WITH CONSTRUCTION PM/ARCHITECT. 1 FIXTURE FLOOR PLAN 1/4" = 1'-0" F-1 N FIXTURE SUMMARY SYMBOL DESCRIPTION SYMBOL DESCRIPTION AB ACCESSORY BAR MM MEN'S MANNEQUIN AC ACCESSORY CONSOLE MR MANNEQUIN RISER AT ACCESSORY TOWER RI RISER NESTER BM-B BRANDY MELVILLE BENCH S SWIM FIXTURE BM-T BRANDY MELVILLE TABLE SC STONE CUBE BW BLACK WARDROBER SMF SMALL MINI FEATURE WALL CTG GLASS CONSOLE TABLE SN SMALL NESTER DT DENIM TABLE 4'X6'ST SHOE TOWER FRB ADA FITTING ROOM BENCH SUNGLASS SUNGLASSES DISPLAY FRS FITTING ROOM STOOL TT TEE TABLE FT FEATURE TABLE 3'X6'TS T-STAND GP GRID PLATFORM TW 4'X4' DISPLAY TABLE GR GLASS ROUND TABLE AND NESTERS WC WHITE CUBE LN LARGE NESTER WFW WHITE FEATURE WALL LWP LARGE WOOD PLATFORM WM WOMEN'S MANNEQUIN MC METAL CUBE WMP WHITE MEDIUM PLATFORM MI BODY MIRROR WW WHITE WARDROBER TOTAL NUMBER OF POS 3 TOTAL NUMBER OF CASH DRAWERS 3 ALL EQUIPMENT, FINISHES, FIXTURES, FURNITURE, AND GRAPHICS TO BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. SEE A701 SERIES SHEETS FOR ALL SCHEDULES. GENERAL NOTES 1.LANDLORD REVIEW IS FOR DESIGN INTENT AND COMPLIANCE WITH LANDLORD’S CRITERIA ONLY. APPROVAL BY LANDLORD OR LANDLORD’S AGENT SHALL NOT CONSTITUTE OR IMPLY A REPRESENTATION OR CERTIFICATION BY LANDLORD THAT THESE DRAWINGS OR TENANT’S WORK IS IN COMPLIANCE WITH INSURANCE AND INDEMNITY REQUIREMENTS, OR ANY LAWS, RULES, REGULATIONS, BUILDING CODES, OR ORDINANCES, INCLUDING BUT NOT LIMITED TO THE AMERICAN WITH DISABILITIES ACT, AND FIRE LIFE SAFETY. FURTHERMORE, LANDLORD ASSUMES NO RESPONSIBILITY FOR THE ENGINEERING OR SAFETY OF TENANT'S DESIGN, NOR IS LANDLORD RESPONSIBLE FOR ANY COORDINATION BETWEEN OTHER TRADES AND JOB CONDITIONS AFFECTED BY TENANT'S WORK. 2.LANDLORD DELIVERS THE PREMISES IN AS-IS CONDITIONS. TENANT IS RESPONSIBLE FOR ALL FIELD VERIFICATION AND MUST DESIGN AND BUILD TO THOSE SPECIFICATIONS. 3.TENANT’S ARCHITECT TO SUBMIT TO CITY FOR PERMIT APPROVAL, ALL PLANS MUST COMPLY WITH LOCAL AND STATE JURISDICTIONS. 4.TENANT’S GC AND ARCHITECT TO FOLLOW RULES AND REGULATIONS AND WESTFIELD DESIGN CRITERIA 5.ANY CHANGES OF STORE DESIGN AND CONSTRUCTION AFTER PLAN APPROVAL MUST BE FORMALLY ADDRESSED WITH WESTFIELD AND THE CITY. 6.TENANT SHALL ENSURE THAT ENTIRE STOREFRONT IS BEHIND THE LEASE LINE. COORDINATE FIELD CONDITIONS WITH WESTFIELD ON-SITE TC/FM. 7.ANY CHANGES TO STORE DESIGN AND CONSTRUCTION DUE TO FIELD CONDITIONS ARE THE FULL RESPONSIBILITY AND SOLE COST TO THE TENANT. 8.TENANT’S GC MUST COORDINATE ANY WORK OUTSIDE LEASE LINE WITH WESTFIELD TC. 9.ANY USE OF EXISTING EQUIPMENT OR OTHERS TO BE BROUGHT UP TO CODE. TENANT IS RESPONSIBLE FOR ANY REQUIRED UPGRADES. 10.ANY IMPORTED ITEMS MUST COMPLY WITH US LOCAL STANDARD WITHOUT IMPACTING THE SCHEDULE. 11.TENANT'S BARRICADE NEEDS TO BE SET UP BEFORE CONSTRUCTION START WITH MALL REQUIRED VENDOR. PLEASE TO ENSURE TO HAVE THE VENDOR TO COORDINATE WITH THE MALL MANAGEMENT FOR PROPER MALL COMMON AREA CLEARANCE. GRAPHIC NEEDS TO BE APPROVED BY MALL MARKETING DIRECTOR. 12.CONTRACTOR MUST CONTACT FACILITY MANAGER FOR A SET OF RULES AND REGULATIONS FOR EACH CENTER. A PRE-CONSTRUCTION MEETING MUST BE HELD WITH FACILITY MANAGER PRIOR TO STARTING ANY CONSTRUCTION WITH AN APPROVED SET OF PLANS FROM THE CITY. 13.GC MUST SCAN OR X-RAY THE SLAB PRIOR TO ANY TRENCH OR CORING. PLEASE CHECK WITH THE MALL FM AND SEND REPORT TO FM/TC FOR REVIEW BEFORE ANY WORK. 14.ANY MALL TILE TO BE PURCHASED FROM MALL FACILITY MANAGER 15.TENANT MUST SURVEY THE SPACE BEFORE ANY DESIGN AND CONSTRUCTION. 16.GC TO USE MALL REQUIRED VENDORS (BARRICADE, FS, FA, ROOFING...ETC.) IF APPLIED. CONTACTS ON MALL CONSTRUCTION MANUAL. 17.WE DELIVER THE SPACE AS IS PENDING TENANT'S POWER AND WATER USAGE. ANY UPGRADE NEEDED PER CODE OR DESIGN WILL BE AT TENANT'S RESPONSIBILITY. 18.NO STURDOR VENT IS ALLOWED. 19.CRANE LIFT NEEDS TO BE APPROVED BY WF RISK MANAGEMENT. IT WILL TAKE ABOUT 2-4 WEEKS FOR REVIEW. GC MUST VIF AND SEND THE RISK MANAGEMENT PACKAGE AT THE BEGINNING OF CONSTRUCTION. 20.TENANT MUST PROVIDE PROPER TENANT SPACE MAIN GAS AND/OR WATER CONTROL VALVE PER CODE AT THE MALL COMMON AREA OR THROUGH ACCESS PANEL AND WITH MALL NAME TAG FOR WAY FINDING. TYP. 21.ANY TENANT’S POWER IS ON MALL HOUSE METER MUST HAVE FUNCTIONAL SUB-METER FOR MALL MONTHLY READING. GC TO VIF AND INSTALL ONE TO MATCH THE EXISTING ONE IN THE MALL AS NEEDED IN YOUR SPACE AND COORDINATE WITH THE MALL FM FURTHER AS NEEDED. 22.IF IS ON EDISON METER, TENANT MUST TRANSFER ACCOUNT TO THEIR NAME, AND COORDINATE WITH MALL FM FOR TEMP POWER AS NEEDED. 23.NO ITEMS OF SIGNIFICANT WEIGHT TO BE SUPPORTED BY DECK. INCLUDING CEILING FRAMING, HVAC AND IT’S TO SPAN FROM STEEL TO STEEL. TENANT TO CHECK WITH THE CITY ON ANY SPECIFIC REQUIREMENTS. 24.GC MUST PROVIDE LABELS (SPACE NAME + WF SPACE # + MAILING ADDRESS #) TO BACK DOOR, POWER BREAKER/METER AT MALL ELECTRICAL ROOM, ANY ROOF UNITS, SPACE WATER SHUT OFF VALVE...ETC. 25.GC TO HIRE MALL REQUIRED FS/FA VENDORS FOR DESIGN/PERMIT AND INSTALLATION PER YOUR DESIGN. 26.ALL COLOR AND MATERIAL SELECTIONS MUST MEET ALL CODE REQUIREMENTS FOR FLAME SPREAD AND SMOKE DEVELOPMENT FACTORS. 27.SUBMIT COLOR AND MATERIAL SAMPLE BOARD FOR REVIEW AND APPROVAL. SUBMIT SAMPLES FOR THE FORWARD SELLING AREAS AND STOREFRONT. IT IS IMPORTANT THAT STOREFRONT SAMPLES BE PART OF THIS SUBMITTAL. 28.ANY EXISTING SYSTEM WITHIN TENANT'S SPACE THAT WILL BE REUSED MUST BE RECONDITIONED TO CURRENT LL'S STANDARDS AND BUILDING CODE AT TENANTS EXPENSE. SURFACE MOUNTED OUTRIGGER , 48" O.C., G.C. REFER TO DETAIL SHEET A523 FOR ATTACHMENT DETAILS. 2 A300 SURFACE MOUNTED OUTRIGGER , 48" O.C., G.C. REFER TO DETAIL SHEET A523 FOR ATTACHMENT DETAILS. 12'-0" MEN'STEE SHOP 12 ' - 0 " GE N D E R N E U T R A L OUTRIGGERS TO BE ATTACHED TO WALL STUDS 4' O.C., TYP. 16'-0" MEN'S DENIM 2'-0" HOLD TS MR WM MM WW FRS FRS FRS FRS FRSFRB STOCK ROOM FITTING ROOMS HALLWAY WOMEN'S TOILET ROOM MEN'S TOILET ROOM HALLWAY SALES AREA CA S H W R A P SC MC MI BW GR GR SMFWFW SUNGLASS AC FT BM - T BM - B BM - BLN RI DT LN RI LN RI DT LN LN RI DT LN RI S 16'-0" BRANDY MELVILLE AND JOHN GALT 20'-0" WOMEN'S DENIM 20'-0" WOMEN'S FASHION 4'-0" TYP. CASH WRAP PROVIDED BY TENANT, INSTALLED BY G.C. REFER TO ELECTRICAL SHEETS FOR ADDITIONAL INFORMATION. 4'-4" CLR. OUTRIGGERS LAYOUT TO START HERE TO MATCH STUD LAYOUT INSIDE THE WALL OUTRIGGERS LAYOUT TO START HERE TO MATCH STUD LAYOUT INSIDE THE WALL ADJACENT TENANT WFWSMF SMFWFWWFWSMF WWWW FN FN AB S WW WW CTG S BW GP GP WM MIAT SC MC LP GP GP MM WM 16 ' - 5 " OP E N T O M A L L 22 ' - 1 " 7'-3" 3 A300 MALL 3'- 0 " 2'- 1 1 " CTG CTG WW FRS FRS FRS S MM GP MM SC MC BW BW BW TT TT MI STST SN TW SN WW WW MR WM MM MR WM MM FN FT AC WW 12 ' - 0 " GE N D E R N E U T R A L TS CTG TS CTG GP WM 1'-9 7/8" HOLD 4'-0" TYP. 3'- 2 " 2'-10" 47 ' - 9 " LE A S E L I N E CORRIDOR 10'-1" A201 1 5 2 3 A202 17 20 19 18 A201 6 10 9 7 A202 1 4 3 2 A401 2A 2D 2C 2B A401 4A 4D 4C 4B A202 9 12 11 10 EXISTING TENANT'S STOREFRONT 5 A201 8 A201 A202 5 8 7 6 A202 13 16 15 14 MR WM MM MR WM MM FN FT FRS WW ADJACENT TENANT LOCATION OF POWER AND DATA OUTLETS AT CENTER OF THE BACK WRAP 7'-0" A.F.F. BACKWRAP & PACSUN LIT SIGN PROVIDED BY TENANT. PROVIDE ELECTRICAL, SEE DETAIL 8/A503 AND ELECTRICAL PLANS. LOCATION OF POWER OUTLET 8" FROM CORNER OF BACK WRAP AND 18" FROM A.F.F. A2014 UNISEX ADA FITTING ROOM UNISEX FITTING ROOMS, TYP. 2' - 0 " HO L D 2' - 2 " HO L D NEW STRUCTURAL COLUMNS (E) COLUMN (E) COLUMN 8" 14 ' - 9 " 3'-8" CLR. (E) COLUMN NEW STRUCTURAL COLUMNS NEW STRUCTURAL COLUMNS (E) VOID LN RI DT LN RI NEW STRUCTURAL COLUMNS 16 ' - 3 " LE A S E L I N E 2 A300 4A A300 4B A300 LOCATION OF POWER OUTLETS. REFER TO ELEVATIONS. 4' - 0 " 2'-0" 4'-4" CLR. A141 FIXTURE PLAN 3 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/25/23 07/24/23 BUILDING COMMENTS 2 OPEN TO SALES FLOOR OPEN TO FITTING ROOMS OPEN TO FITTING ROOMS OPEN TO SALES FLOOR OPEN TO SALES FLOOR GROUND 0'-0" TYP 1 INTERIOR ELEVATION 1/4" = 1'-0" 20 " MA X . 3'- 1 0 " PT-1 B-1 7' - 6 " PT-1 B-1 PT-1 B-1 PT-1 B-1 SURFACE MOUNTED OUTRIGGERS, 48", BOTTOM OF MOUNTING PLATE AT 5" A.F.F. LASER LEVEL CENTER LINE OF MOUNTING HOLES AND OUTRIGGER SLOTS ALIGN ACROSS ALL OUTRIGGERS AS WELL AS TOP AND BOTTOM. GROUND 0'-0" 3 INTERIOR ELEVATION 1/4" = 1'-0" 5 INTERIOR ELEVATION 1/4" = 1'-0" 2 INTERIOR ELEVATION 1/4" = 1'-0" GROUND 0'-0" 5 SECTION @ FITTING ROOMS 1/4" = 1'-0" GROUND 0'-0" 6 INTERIOR ELEVATION 1/4" = 1'-0" GROUND 0'-0" 7 INTERIOR ELEVATION 1/4" = 1'-0"8 SECTION @ FITTING ROOMS 1/4" = 1'-0"9 INTERIOR ELEVATION 1/4" = 1'-0"10 INTERIOR ELEVATION 1/4" = 1'-0" TYP TYP TYPF-1 B-2 PT-3 WALL MOUNTED OCCUPANCY SENSOR W/ DIMMING CAPABILITIES. REFER TO ELECTRICAL PLANS FOR MORE INFORMATION. B.O. SOFFIT 10'-0" TYP TYPB-2 PT-3 TYP TYPB-2 PT-3 EMPLOYEE SIDE OF CUSTOM CASHWRAP FIXTURE BY OWNER. 11'-2"W X 2'-8" CUSTOM BACKWRAP FIXTURE BY OWNER. 98-1/2"W X 34"H SURFACE MOUNTED OUTRIGGERS, 48", BOTTOM OF MOUNTING PLATE AT 5" A.F.F. LASER LEVEL CENTER LINE OF MOUNTING HOLES AND OUTRIGGER SLOTS ALIGN ACROSS ALL OUTRIGGERS AS WELL AS TOP AND BOTTOM. TYP F-1 TYP TYPB-2 PT-3 TYP F-1 TYP TYP B-2 PT-3 TYP TYPB-2 PT-3 1' - 0 " 8' - 6 " T Y P . B. O . L I G H T F I X T U R E MAPLE JAMB MAPLE DOOR FINISH TYP TYP MAPLE JAMB MAPLE DOOR FINISH TYP TYP MAPLE JAMB MAPLE DOOR FINISH TYP TYP PT-1 B-1 PT-1 B-1 4 INTERIOR ELEVATION 1/4" = 1'-0" SURFACE MOUNTED OUTRIGGERS, 48", BOTTOM OF MOUNTING PLATE AT 5" A.F.F. LASER LEVEL CENTER LINE OF MOUNTING HOLES AND OUTRIGGER SLOTS ALIGN ACROSS ALL OUTRIGGERS AS WELL AS TOP AND BOTTOM, TYP. 24'-7"6'-7"24'-7" 5' - 1 " 18 " 8"LOCATION OF ELECT. OUTLET 18" A.F.F. AND 8" FROM CORNER OF BACKWRAP. REFER TO ELECTRICAL DRAWINGS FOR MORE INFO. 3'-8" ℄ ℄PT-1 B-1 PT-1 B-1 PT-1 B-1TYP 10 A502 TYP. TACTILE EXIT SIGN ON INTERIOR. REFER TO G002 SHEET FOR MORE INFORMATION. 9 A502 B.O.DECK +/- 20'-0" GROUND 0'-0" PT-1 B-1 B.O.DECK +/- 20'-0" TYP. NEW STOREFRONT GROUND 0'-0" B.O.DECK +/- 20'-0" ℄ 3'-0" OPENING B.O. HEADER 7'-0" PT-1 B-1 SURFACE MOUNTED OUTRIGGERS, 48", BOTTOM OF MOUNTING PLATE AT 5" A.F.F. LASER LEVEL CENTER LINE OF MOUNTING HOLES AND OUTRIGGER SLOTS ALIGN ACROSS ALL OUTRIGGERS AS WELL AS TOP AND BOTTOM, TYP. 24'-7"24'-7" GROUND 0'-0" B.O.DECK +/- 20'-0" B.O. HEADER 7'-0" 10 A502 TYP. 10 A502 TYP. 10 A502 TYP. 9 A502 9 A502 9 A502 T.O. PTHT. WALL 8'-0" ADD BLOCKING BEHIND HOOKS, TYP. TYP HOOK-1 T.O. PTHT. WALL 8'-0" B.O.DECK +/- 20'-0" B.O.DECK +/- 20'-0" B.O.DECK +/- 20'-0" B.O. FIXTURE 8'-6" TYP. 20 " M A X . B.O . M I R R O R WALL MOUNTED MIRRORS ARE TO BE CAULKED AROUND FRAME TOUCHING WALL, TYP. 4'-0" 6' - 0 " 2 A503 GROUND 0'-0" B.O.DECK +/- 20'-0" T.O. PTHT. WALL 8'-0" TYP. TYP. TYP. TYP. GROUND 0'-0" B.O.DECK +/- 20'-0" T.O. PTHT. WALL 8'-0" GROUND 0'-0" B.O.DECK +/- 20'-0" T.O. PTHT. WALL 8'-0" 3'-0" 6' - 0 " 6'-7" 5 A503 CUSTOM BACKWRAP FIXTURE BY OWNER. 98-1/2"W X 34"H 4'- 5 " B.O. SOFFIT 10'-0" B.O. SOFFIT 10'-0" 16'-0" OPEN TO MALL 8'- 6 " T Y P . B. O . L I G H T F I X T U R E 8' - 6 " T Y P . B. O . L I G H T F I X T U R E 8'- 6 " T Y P . B. O . L I G H T F I X T U R E 3'-0" 6' - 0 " 2 A503 TYP. 8' - 6 " T Y P . B. O . L I G H T F I X T U R E NEW STOREFRONTNEW STOREFRONT 4 A503 TYP. 7'- 6 " EQ.EQ. PROVIDE ELECTRICAL FOR ILLUMINATED EDGE SIGN 8" ℄ INTERIOR ELEVATIONS A201 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 T.O. FRP 4'-0" 1'-4"1'-4"EQ.EQ. 5' - 6 " T. O . H O O K HOOK-1 OPEN TO FITTING ROOMS OPEN TO SALES FLOOR 2 INTERIOR ELEVATION 1/4" = 1'-0"3 INTERIOR ELEVATION 1/4" = 1'-0"4 INTERIOR ELEVATION 1/4" = 1'-0"5 INTERIOR ELEVATION 1/4" = 1'-0"6 INTERIOR ELEVATION 1/4" = 1'-0"7 INTERIOR ELEVATION 1/4" = 1'-0"8 INTERIOR ELEVATION 1/4" = 1'-0" GROUND 0'-0" 9 INTERIOR ELEVATION 1/4" = 1'-0" GROUND 0'-0" 10 INTERIOR ELEVATION 1/4" = 1'-0" GROUND 0'-0" 11 INTERIOR ELEVATION 1/4" = 1'-0" GROUND 0'-0" 12 INTERIOR ELEVATION 1/4" = 1'-0" GROUND 0'-0" 17 INTERIOR ELEVATION 1/4" = 1'-0" 19 INTERIOR ELEVATION 1/4" = 1'-0"20 INTERIOR ELEVATION 1/4" = 1'-0" ADD BLOCKING BEHIND HOOKS, TYP. ℄ WALL MOUNTED OCCUPANCY SENSOR W/ DIMMING CAPABILITIES. REFER TO ELECTRICAL PLANS FOR MORE INFORMATION. WALL MOUNTED OCCUPANCY SENSOR W/ DIMMING CAPABILITIES. REFER TO ELECTRICAL PLANS FOR MORE INFORMATION. FRP-1 B-4 KICK PLATEFRP-1 B-4 27 " M I N . C L R . 36 " M A X . T O T O P O F B U B B L E R 32 " M I N . C L R . 40 " - 4 2 " T O T O P O F B U B B L E R 60 " M I N . WOMEN'S ADA RESTROOM SIGN, 12" DIA. CIRCLE. 60 " M I N . MEN'S ADA RESTROOM SIGN, 10" W. 1/4" THICK TRIANGLE. KICK PLATE KICK PLATE B-2 PT-3 TYP HOOK-1 TYP F-1 TYP TYPB-2 PT-3 TYP TYPB-2 PT-3 TYP TYPB-2 PT-3 PT-3 B-2 PT-3 TYP HOOK-1 ℄℄ 5' - 6 " T. O . H O O K FRP-1 B-4 FRP-1 B-4 FRP-1 B-4 FRP-1 B-4 PT-1 B-4 6 A503 TYP. 1"X4" FIRE TREATED POPLAR STRAPPING INSTALLED HORIZONTALLY BEHIND ALL WALL STANDARDS, 24" O.C. (SECURE TO WALL STUDS) 10' SURFACE MOUNTED HEAVY DUTY WALL STANDARDS, 48" O.C. MAX, CUT TO LENGTH AS REQUIRED 3 A502 1"X4" FIRE TREATED POPLAR STRAPPING INSTALLED HORIZONTALLY BEHIND ALL WALL STANDARDS, 48" O.C. (SECURE TO WALL STUDS) 10' SURFACE MOUNTED HEAVY DUTY WALL STANDARDS, 48" O.C. MAX, CUT TO LENGTH AS REQUIRED GROUND 0'-0" 13 INTERIOR ELEVATION 1/4" = 1'-0" GROUND 0'-0" 14 INTERIOR ELEVATION 1/4" = 1'-0" CEILING 9'-0" CEILING 9'-0" CEILING 9'-0" CEILING 9'-0" CEILING 9'-0" CEILING 9'-0" CEILING 9'-0" GROUND 0'-0" 15 INTERIOR ELEVATION 1/4" = 1'-0" PT-3 B-2 PT-3 B-2 PT-3 B-2 EQ EQ B-2 PT-3 TYP F-1 ℄ TYPB-2 TYP ADD BLOCKING BEHIND HOOKS, TYP. MAPLE JAMB MAPLE DOOR FINISH TYP TYP MAPLE JAMB MAPLE DOOR FINISH TYP TYP PT-1 PT-1 PT-1 PT-1 PT-1 EQEQ3'-5 1/2" TYP TYPFILE CABINET PT-1 B-4 TYP TYP PT-1 B-4 TYP TYP EQ EQ GROUND 0'-0" 1 INTERIOR ELEVATION 1/4" = 1'-0" B-2 PT-3 TYP F-1 ℄ B.O.DECK +/- 20'-0" GROUND 0'-0" B.O.DECK +/- 20'-0" GROUND 0'-0" B.O.DECK +/- 20'-0" GROUND 0'-0" B.O.DECK +/- 20'-0" GROUND 0'-0" B.O.DECK +/- 20'-0" GROUND 0'-0" B.O.DECK +/- 20'-0" GROUND 0'-0" B.O.DECK +/- 20'-0" GROUND 0'-0" B.O.DECK +/- 20'-0" EQ EQ℄ 7'-4 5/8" TYP TYP B.O. HEADER 8'-0" B.O. HEADER 8'-0" T.O. PTHT. WALL 8'-0" T.O. PTHT. WALL 8'-0" T.O. PTHT. WALL 8'-0" T.O. PTHT. WALL 8'-0" CEILING 9'-0" GROUND 0'-0" 16 INTERIOR ELEVATION 1/4" = 1'-0" PT-3 B-2 B.O.DECK +/- 20'-0" (E) COLUMN MINI FRIDGE MANAGER DESK 32"H x 72"W x 30"D SAFE ELECTRICAL PANELS MICROWAVE KICK PLATEKICK PLATE 18 INTERIOR ELEVATION 1/4" = 1'-0" 8' SURFACE MOUNTED HEAVY DUTY WALL STANDARDS, 24" O.C. MAX, CUT TO LENGTH AS REQUIRED 7'-10" SURFACE MOUNTED HEAVY DUTY WALL STANDARDS, 24" O.C. MAX, CUT TO LENGTH AS REQUIRED LOCKERSPT-1 B-4 CG-1 HANGBARSTYP TYP GROUND 0'-0" B.O.DECK +/- 20'-0" GROUND 0'-0" B.O.DECK +/- 20'-0" GROUND 0'-0" B.O.DECK +/- 20'-0" (E) COLUMN BAR BIN HARDWARE BIN MOP SINK DATA BOARD MANAGER DESK KICK PLATE KICK PLATE 4'- 0 " T. O . H O O K PROCESSING DESK 42"H x 72"W x 30"D KICK PLATE 1 A503 TYP. 20 " MA X . 3'-0" 6'- 0 " 2 A503 TYP. WALL MOUNTED MIRRORS ARE TO BE CAULKED AROUND FRAME TOUCHING WALL, TYP. 3'-0" WALL MOUNTED MIRRORS ARE TO BE CAULKED AROUND FRAME TOUCHING WALL, TYP. 20 " MA X . 6'- 0 " 20 " MA X . 3'-0" 6'- 0 " 2 A503 TYP. WALL MOUNTED MIRRORS ARE TO BE CAULKED AROUND FRAME TOUCHING WALL, TYP. 3'-0" OPEN 3'-6"3'-6"EQ.EQ.℄℄℄ 4'- 3 " B . O . B O A R D BULLETIN BOARDS SIZED 36"W X 48"H, TO BE MOUNTED FROM BOTTOM OF BOARD 4'-3" A.F.F., TYP. 5 A561 5 G002 TYP. 5 G002 TYP. 4 A503 TYP. 3'-0" OPEN 8' - 6 " T Y P . B. O . L I G H T F I X T U R E TRANSFORMER T.O. DOOR 7'-0" T.O. PLHT. WALL 5'-0" T.O. DOOR 7'-0" T.O. DOOR 7'-0" T.O. DOOR 7'-0" T.O. DOOR 7'-0" T.O. DOOR 7'-0" 5 A502 3 A502 4 A502 4 A502 SIM. 3 A503 TYP. 3 A503 TYP. 2'-7"3'-9" 3' - 7 " 6' - 1 " T.O. FRP 4'-0" T.O. FRP 4'-0" T.O. FRP 4'-0" 1 A503 TYP. 2 INTERIOR ELEVATIONS A202 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 2 2 5" V.I.F. 1 STOREFRONT PLAN VIEW 3/8" = 1'-0" 1 0 ' - 1 " 3'-2"3'-0"16'-0" OPENING 47'-9" LEASE LINE LEASE LINE LEASE LINE 2 - 3 - 1 1 " EXISTING ADJACENT TENANT STOREFRONT TO REMAIN. 2'-11"2 -22'-7" 6 ' - 9 " 2 ' - 1 0 " 47'-8" EQ.EQ.SECURITY ROLL-UP GRILLE 2 STOREFRONT ELEVATION 3/8" = 1'-0" 3 STOREFRONT SIDE ELEVATION 3/8" = 1'-0" GROUND 0'-0" GROUND 0'-0" TYP SF-1 10'-1" 10 ' - 0 " 15 ' - 1 0 " 5' - 1 0 " SF-1 TYP 10 ' - 0 " LEASE LINE 15 ' - 1 0 " 5' - 1 0 " OPEN TO SALES FLOOR T.O. WINDOWS 10'-0" V.I.F. 1' - 0 " T.O. WINDOWS 10'-0" V.I.F. 16'-0" 1.G.C. TO VERIFY FIELD CONDITIONS AND DIMENSIONS AND NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES AFTER DEMOLITION AND PRIOR TO RECLADDING OR CONSTRUCTION. G.C. TO FIELD VERIFY ALL DIMENSIONS PRIOR TO ORDERING ANY MATERIALS. 2.G.C. TO VERIFY AND INSTALL BLOCKING FOR EXTERIOR SIGNAGE AS REQUIRED. COORDINATE WITH LANDLORD AND SIGNAGE VENDOR REGARDING LOCATION OF SIGNAGE AND EXISTING SHELL CONSTRUCTION/FINISH CONDITIONS. 3.SIGN MANUFACTURER TO REVIEW THE LANDLORD'S SIGN CRITERIA AND SUBMIT SHOP DRAWINGS FOR THE PROPOSED SIGN TO THE LANDLORD AND ANY OTHER GOVERNING AUTHORITIES. THE SIGN MANUFACTURER SHALL SECURE ANY AND ALL PERMITS REQUIRED FOR THE INSTALLATION AND DISPLAY OF THE PROPOSED SIGNAGE. 4.SIGN MANUFACTURER'S SHOP DRAWINGS SHALL BE REVIEWED UNDER SEPARATE SUBMITTAL. 5.SIGNAGE AS SHOWN IN THESE DRAWINGS IS SCHEMATIC ONLY FOR ILLUSTRATION PURPOSES AND DOES NOT IMPLY OR DESCRIBE ANY MEANS, METHODS, OR DETAILS PERTAINING TO INSTALLATION OF SIGNAGE. IT SHALL BE SOLELY THE SIGN MANUFACTURER'S RESPONSIBILITY TO DESIGN, FABRICATE, AND INSTALL THE SIGN UNDER SEPARATE PERMIT. ANY AND ALL STRUCTURAL CONSIDERATIONS SHALL BE COORDINATED BETWEEN THE SIGN MANUFACTURER, THE LANDLORD, AND HIS DESIGN PROFESSIONALS. 6.SUITE NUMBERS SHOULD BE A MINIMUM OF 3" HIGH, 1/2” STROKE WIDE, AND A CONTRASTING COLOR. PREMISES IDENTIFICATION MUST BE VISIBLE FROM STREET OR DRIVE. ALL EXTERIOR SUITE DOORS SHALL BE LABELED. POST 6" STREET NUMBERS AND 3" SUITE NUMBERS. COORDINATE WITH LANDLORD REPRESENTATIVE AND PACSUN CONSTRUCTION PM FOR FINAL PLACEMENT OF SUITE NUMBERS. 7.ALL MATERIALS TO BE A CLASS A RATING WITH A FLAME SPREAD INDEX OF 0-25 AND A SMOKE DEVELOPED INDEX OF 0-450. GENERAL NOTES 18 " MA X . 47'-8"16'-1" 1.REMOVAL OR ADDITION OF INTERIOR WALLS SHALL REQUIRE A PERMIT FROM THE ARCADIA BUILDING DIVISION, (626) 574-5448. 2.A BUSINESS LICENSE SHALL BE OBTAINED FROM THE BUSINESS LICENSE OFFICE, (626) 574-5430. 3.MINIMUM RATED 2A:10BC FIRE EXTINGUISHERS SHALL BE PROVIDED IN APPROVED LOCATIONS. THE TRAVEL DISTANCE TO AN EXTINGUISHER SHALL NOT EXCEED 75 FEET. 4.A KNOX BOX SHALL BE PROVIDED ADJACENT TO THE FRONT ENTRANCE AND MOUNTED NO HIGHER THAN 18 INCHES A.F.F. KEYS TO THE FRONT ENTRANCE SHALL BE PROVIDED TO THE FIRE DEPARTMENT AND PLACED IN THE KNOX BOX FOR EMERGENCY USE ONLY. 5.ANY MODIFICATIONS TO THE FIRE SPRINKLER OR FIRE ALARM SYSTEM SHALL REQUIRE A SEPARATE PERMIT. MODIFICATION TO AN EXISTING SPACE REQUIRING A BUILDING PERMIT SHALL ALSO REQUIRE FULL SMOKE DETECTION FOR THE SPACE. 6.FOR NEW OR TEMPORARY TENANTS, ANY EXISTING SMOKE AND/OR HEAT DETECTORS IN THE SPACE SHALL BE REPROGRAMMED TO REFLECT THE NEW TENANCY. CONTACT THE MALL FIRE ALARM CONTRACTOR TO CONDUCT THE PROPER PROGRAMMING. 7.ALL REQUIRED EXIT SIGNAGE AND EMERGENCY LIGHTING SHALL BE FUNCTIONING PROPERLY. 8.EXIT PATHS SHALL BE KEPT CLEAR AT ALL TIMES, INCLUDING REAR HALLWAYS AND CORRIDORS. ALL EXIT DOORS SHALL BE EASILY OPENED. ANY LOCKING DEVICES SHALL REQUIRE ONLY ONE ACTION AND NO SPECIAL KNOWLEDGE TO OPERATE. 9.THERE SHALL BE A MINIMUM CLEAR SPACE OF 36” IN FRONT OF ELECTRICAL PANELS AND TRANSFORMERS. ELECTRICAL ROOMS SHALL BE KEPT CLEAR OF STORAGE. LANDLORD REQUIREMENT NOTES NEW STRUCTURAL COLUMN, REFER TO STRUCTURAL. PAINTED PT-1 PER FINISH PLAN. TYP. EXISTING COLUMN WITH NEW FURRING, PAINTED PT-1 WITH BASE B-1. PER FINISH PLAN. 1 A301 2 A301 4 A303 3 A203 3 A203 6 A203 6 A203 1 A203 1 A203 1 A203 6 A203 2'-4" 6' - 2 " 6' - 2 " 22'-10" 8' - 7 " 8' - 7 " 2'-4"2'-4"2'-4" 2'-4"17'-1" NEW STRUCTURAL COLUMN, REFER TO STRUCTURAL. PAINTED PT-1 PER FINISH PLAN. TYP. NEW STRUCTURAL COLUMN, REFER TO STRUCTURAL. PAINTED PT-1 PER FINISH PLAN. TYP. 1 A302 2 A302 NEW STRUCTURAL STOREFRONT COLUMN SUPPORTS, REFER TO STRUCTURAL, TYP. STRUCTURAL COLUMNS, REFER TO STRUCTURAL, TYP. EXISTING NEUTRAL PIER TO REMAIN. PATCH AND REPAIR AS NEEDED. PREP SURFACE TO BE PAINTED PT-6 PER MALL REQUIREMENT, TYP. PER MALL REQUIREMENTS, ALL NEUTRAL PIER TO BE PAINTED PT-6, TYP. SIGN BY OTHERS PT-6 5 A303 9 A303 EXISTING NEUTRAL PIER TO REMAIN. PATCH AND REPAIR AS NEEDED. PREP FOR MALL REQUIRED FINISHES.SF-1 TYP 4 A303 ℄℄℄℄℄ ℄℄℄℄℄℄ 12 A203 3 A203 8 A203 8 A203 3 A203 3 A203 4 STOREFRONT ENTRY ELEVATIONS 3/8" = 1'-0" GROUND 0'-0" T.O. WINDOWS 10'-0" V.I.F. 6'-9" NEW STRUCUTRAL COLUMN FURRING, REFER TO STRUCTURAL. PAINTED PT-1 WITH BASE B-1. PER FINISH PLAN. NEW STRUCUTRAL COLUMNS FURRING, REFER TO STRUCTURAL. PAINTED PT-1 WITH BASE B-1 AT INTERIOR. PER FINISH PLAN. 13'-1" 3'-4"3'-0" SECURITY ROLL-UP GRILLE CHANNELS. 3' - 4 " 3' - 4 " SIM. 4A - A STOREFRONT LEFT ENTRY ELEVATION B STOREFRONT RIGHT ENTRY ELEVATION 4B - LOCATION OF KNOX BOX, MOUNTED 18" A.F.F. MAX PER MALL REQUIREMENT. 8' - 7 " 4 A303 4 A303 SIM. SF-1 PT-1 1'-2" 1'-2" 4 A303 4 A303 SECURITY GRILLE GUIDE REFER TO DETAIL. BASE BOARD. REFER TO DETAIL. B-1 TOP MOTORIZED QMI OR APPROVED EQ. STORE SAFE AL7 W/ STYLE 51 PUNCH PATTERN WITH KEY SWITCH TO ACCEPT BEST 7 PIN CORE. REFER TO DETAILS. DOOR TO REMAIN OPEN DURING OPERATING HOURS. EQ EQ EQ EQ EQ 13 A303 T.O. STOREFRONT 15'-10" V.I.F. 14'-9"22'-7" EQ. EQ. EQ.14'-9" 8" 16'-3" LEAS E L I N E 8" 6'-9" 6 " T.O. STOREFRONT 15'-10" V.I.F. 117° 14 A303 2 ' - 0 " 1 ' - 8 " EXISTING NEUTRAL PIER TO REMAIN. PATCH AND REPAIR AS NEEDED. PREP FOR MALL REQUIRED FINISHES. INTERIOR MALL MALL MTL-1 TYP MTL-1 TYP MTL-1 TYP STOREFRONT PLAN AND ELEVATIONS A300 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 GROUND 0'-0" 1 STOREFRONT SECTION @ ENTRANCE 3/4" = 1'-0" 1 A303 2 STOREFRONT SECTION @ GLAZING 3/4" = 1'-0" MALLSALES AREA DECK GROUND 0'-0" 2 A501 B.O. DECK (E) 21'-6" V.I.F. (E ) M A L L B U L K H E A D (E) MALL BULKHEAD B.O. SOFFIT 10'-0" B.O. MALL BULKHEAD (E) 21'-6" V.I.F. SALES AREA 10 " 9 A505 MALL B.O. MALL BULKHEAD (E) 15'-9 " V.I.F. B.O. DECK (E) 21'-6" V.I.F. (E ) M A L L B U L K H E A D (E) MALL BULKHEAD B.O. SOFFIT 10'-0" 10'-0" SOFFIT B.O. SOFFIT 10'-0" B.O. MALL BULKHEAD (E) 21'-6" V.I.F. SALES AREA 9 A505 2 A505 7 A303 3'-4" 6 A303 B.O. SIGNAGE 12'-2" 2" HOLD 1.G.C. TO VERIFY FIELD CONDITIONS AND DIMENSIONS AND NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES AFTER DEMOLITION AND PRIOR TO RECLADDING OR CONSTRUCTION. G.C. TO FIELD VERIFY ALL DIMENSIONS PRIOR TO ORDERING ANY MATERIALS. 2.G.C. TO VERIFY AND INSTALL BLOCKING FOR EXTERIOR SIGNAGE AS REQUIRED. COORDINATE WITH LANDLORD AND SIGNAGE VENDOR REGARDING LOCATION OF SIGNAGE AND EXISTING SHELL CONSTRUCTION/FINISH CONDITIONS. 3.SIGN MANUFACTURER TO REVIEW THE LANDLORD'S SIGN CRITERIA AND SUBMIT SHOP DRAWINGS FOR THE PROPOSED SIGN TO THE LANDLORD AND ANY OTHER GOVERNING AUTHORITIES. THE SIGN MANUFACTURER SHALL SECURE ANY AND ALL PERMITS REQUIRED FOR THE INSTALLATION AND DISPLAY OF THE PROPOSED SIGNAGE. 4.SIGN MANUFACTURER'S SHOP DRAWINGS SHALL BE REVIEWED UNDER SEPARATE SUBMITTAL. 5.SIGNAGE AS SHOWN IN THESE DRAWINGS IS SCHEMATIC ONLY FOR ILLUSTRATION PURPOSES AND DOES NOT IMPLY OR DESCRIBE ANY MEANS, METHODS, OR DETAILS PERTAINING TO INSTALLATION OF SIGNAGE. IT SHALL BE SOLELY THE SIGN MANUFACTURER'S RESPONSIBILITY TO DESIGN, FABRICATE, AND INSTALL THE SIGN UNDER SEPARATE PERMIT. ANY AND ALL STRUCTURAL CONSIDERATIONS SHALL BE COORDINATED BETWEEN THE SIGN MANUFACTURER, THE LANDLORD, AND HIS DESIGN PROFESSIONALS. GENERAL NOTES 2 A303 2" HOLD 10'-0" SOFFIT 8"1'-3" B.O. MALL BULKHEAD (E) 15'-9 " V.I.F. B.O. SOFFIT 10'-0" TYP. TYP. B.O. BOX BEAM 10'-4" TYP.TYP. TYP. 6" TYP. TYP. B.O. BOX BEAM 10'-4" T.O. STOREFRONT 15' - 10"TYP. DECK 2 A501 EXISTING DECK TO REMAIN. ATTACHMENT TO BOTTOM OF DECK. REFER TO DETAIL AND STRUCTURAL DETAILS FOR MORE INFORMATION, TYP. EXISTING ROOF FRAMING TO REMAIN. PREPARE SURFACES FOR FINISHES, TYP. EXISTING MALL BULKHEAD TO REMAIN. PROTECT DURING CONSTRUCTION. PATCH AND REPAIR AS NEEDED AND PAINT PT-7 PER MALL REQUIRED SPECS. BOX BEAM. REFER TO STRUCTURAL, TYP. STOREFRONT BASE. REFER TO DETAIL. STOREFRONT GLASS GLAZING. ALL STOREFRONT GLASS SHALL BE TEMPERED PLATE GLASS WITH MAX. 1/8" JOINTS WITH CLEAR CAULK. NEW STOREFRONT COLUMNS. REFER TO STRUCTURAL, TYP. 3 5/8" 20 GA METAL STUD DIAGONAL BRACING @ 48" O.C. REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATION, TYP. SECURITY GRILLE. LEASE LINE. NEW STOREFRONT COLUMN BEYOND. FINISHED PT-1 PER PLANS. REFER TO STRUCTURAL, TYP. 18" SIGN MOUNTED ON WALL INTERNALLY ILLUMINATED SIGNAGE ALIGNED WITH ENTRY DOOR. UNDER SEPARATE PERMIT BY SIGN VENDOR. SECURITY GRILLE HOUSING AS SPECIFIED. BOX BEAM. REFER TO STRUCTURAL, TYP. BLOCKING AS REQUIRED, TYP. RECESSED GRILLE GUIDE, TYP. G.C. TO FINISH RECESS 6" INTO SOFFIT GYP. SO THAT GRILLE CAN BE FULLY RECESSED AND CONCEALED WITH CORNER GUARDS. GRILLE SALES AREA WALLS TO BE FINISHED PT-1 PER PLANS. 5/8" TYPE "X" GYP. OVER 3 5/8" 20 GA. METAL STUD. LEASE LINE. STOREFRONT FINISH RECESSED AT HEADER, SO THAT GLAZING CAN BE FULLY RECESSED AND CONCEALED. SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80. MALL COMMON AREA FINISH FLOOR AREA TO BE PATCHED AND REPAIRED BY TENANT AS NECESSARY UP TO STOREFRONT. 2x 1/2" CEMENT BOARD OVER 3 5/8" 20 GA. METAL STUDS. SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80. 2x 1/2" CEMENT BOARD OVER 2 1/2" 20 GA. METAL STUDS. 6" 20 GA METAL STUD VERTICAL BRACING. REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATION, TYP. 5/8" TYPE "X" GYP. OVER 6" 20 GA. METAL STUD. #10-16 SS TEK SCREWS, TYP. PT-1 5/8" TYPE "X" GYP. OVER 6" 20 GA. METAL STUD. PT-1 SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80 ON WALL BEYOND. 2" GLAZING TOP CONNECTION, FINISH TO MATCH STOREFRONT SYSTEM, TYP. 6" 20 GA. METAL STUDS. ATTACHMENT TO 3 5/8" GA METAL STUD. REFER TO STRUCTURAL, TYP. ATTACHMENT TO EXISTING MALL BULKHEAD. REFER TO STRUCTURAL. B-1 TENANT FINISH FLOOR NEW STOREFRONT COLUMN BEYOND. FINISHED PT-1 PER PLANS. REFER TO STRUCTURAL, TYP. SALES AREA WALLS TO BE FINISHED PT-1 PER PLANS. TENANT FINISH FLOOR MALL COMMON AREA FINISH FLOOR AREA TO BE PATCHED AND REPAIRED BY TENANT AS NECESSARY UP TO STOREFRONT. PT-1 B-1 BOX BEAM. REFER TO STRUCTURAL, TYP. 5/8" TYPE "X" GYP. OVER 6" 20 GA. METAL STUD. PT-1 BOX BEAM. REFER TO STRUCTURAL, TYP. STOREFRONT FINISH RECESSED AT HEADER, SO THAT SECURITY GRILLE CAN BE FULLY RECESSED AND CONCEALED. SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80. 2x 1/2" CEMENT BOARD OVER 3 5/8" 20 GA. METAL STUDS. 2x 1/2" CEMENT BOARD OVER 2 1/2" 20 GA. METAL STUDS. 2x 1/2" CEMENT BOARD OVER 6" 20 GA. METAL STUDS. LEASE LINE. SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80. 2x 1/2" CEMENT BOARD OVER 2 1/2" 20 GA. METAL STUDS. ATTACHMENT TO 3 5/8" GA METAL STUD. REFER TO STRUCTURAL, TYP. ATTACHMENT TO EXISTING MALL BULKHEAD. REFER TO STRUCTURAL. EXISTING MALL BULKHEAD TO REMAIN. PROTECT DURING CONSTRUCTION. PATCH AND REPAIR AS NEEDED AND PAINT PT-7 PER MALL REQUIRED SPECS. 6" 20 GA. METAL STUDS. EXISTING ROOF FRAMING TO REMAIN. PREPARE SURFACES FOR FINISHES, TYP. 6" 20 GA METAL STUD VERTICAL BRACING. REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATION, TYP. 5/8" TYPE "X" GYP. OVER 6" 20 GA. METAL STUD. #10-16 SS TEK SCREWS, TYP. PT-1 3 5/8" 20 GA METAL STUD DIAGONAL BRACING @ 48" O.C. REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATION, TYP. EXISTING DECK TO REMAIN. ATTACHMENT TO BOTTOM OF DECK. REFER TO DETAIL AND STRUCTURAL DETAILS FOR MORE INFORMATION, TYP. T.O. STOREFRONT 15' - 10" T.O. STUD 15'-4" T.O. STUD 15'-4" STOREFRONT SECTIONS AND DETAILS A301 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 2 1 STOREFRONT SECTION @ GLAZING 3/4" = 1'-0" 1.G.C. TO VERIFY FIELD CONDITIONS AND DIMENSIONS AND NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES AFTER DEMOLITION AND PRIOR TO RECLADDING OR CONSTRUCTION. G.C. TO FIELD VERIFY ALL DIMENSIONS PRIOR TO ORDERING ANY MATERIALS. 2.G.C. TO VERIFY AND INSTALL BLOCKING FOR EXTERIOR SIGNAGE AS REQUIRED. COORDINATE WITH LANDLORD AND SIGNAGE VENDOR REGARDING LOCATION OF SIGNAGE AND EXISTING SHELL CONSTRUCTION/FINISH CONDITIONS. 3.SIGN MANUFACTURER TO REVIEW THE LANDLORD'S SIGN CRITERIA AND SUBMIT SHOP DRAWINGS FOR THE PROPOSED SIGN TO THE LANDLORD AND ANY OTHER GOVERNING AUTHORITIES. THE SIGN MANUFACTURER SHALL SECURE ANY AND ALL PERMITS REQUIRED FOR THE INSTALLATION AND DISPLAY OF THE PROPOSED SIGNAGE. 4.SIGN MANUFACTURER'S SHOP DRAWINGS SHALL BE REVIEWED UNDER SEPARATE SUBMITTAL. 5.SIGNAGE AS SHOWN IN THESE DRAWINGS IS SCHEMATIC ONLY FOR ILLUSTRATION PURPOSES AND DOES NOT IMPLY OR DESCRIBE ANY MEANS, METHODS, OR DETAILS PERTAINING TO INSTALLATION OF SIGNAGE. IT SHALL BE SOLELY THE SIGN MANUFACTURER'S RESPONSIBILITY TO DESIGN, FABRICATE, AND INSTALL THE SIGN UNDER SEPARATE PERMIT. ANY AND ALL STRUCTURAL CONSIDERATIONS SHALL BE COORDINATED BETWEEN THE SIGN MANUFACTURER, THE LANDLORD, AND HIS DESIGN PROFESSIONALS. GENERAL NOTES 1 A303 MALLSALES AREA DECK GROUND 0'-0" 2 A501 B.O. DECK (E) 21'-6" V.I.F. (E ) M A L L B U L K H E A D (E) MALL BULKHEAD B.O. SOFFIT 10'-0" B.O. MALL BULKHEAD (E) 21'-6" V.I.F. SALES AREA 10 " 9 A505 6 A3032" HOLD 10'-0" SOFFIT 8" B.O. MALL BULKHEAD (E) 15'-9 " V.I.F. B.O. SOFFIT 10'-0" TYP. TYP. B.O. BOX BEAM 10'-4" TYP. 1 A303 2 STOREFRONT SECTION @ GLAZING 3/4" = 1'-0" MALLSALES AREA DECK GROUND 0'-0" 2 A501 B.O. DECK (E) 21'-6" V.I.F. (E ) M A L L B U L K H E A D (E) MALL BULKHEAD B.O. SOFFIT 10'-0" B.O. MALL BULKHEAD (E) 21'-6" V.I.F. SALES AREA 10 " 9 A505 6 A3032" HOLD 10'-0" SOFFIT 6" B.O. MALL BULKHEAD (E) 15'-9 " V.I.F. B.O. SOFFIT 10'-0" TYP. TYP. B.O. BOX BEAM 10'-4" TYP. EXISTING DECK TO REMAIN. ATTACHMENT TO BOTTOM OF DECK. REFER TO DETAIL AND STRUCTURAL DETAILS FOR MORE INFORMATION, TYP. EXISTING ROOF FRAMING TO REMAIN. PREPARE SURFACES FOR FINISHES, TYP. EXISTING MALL BULKHEAD TO REMAIN. PROTECT DURING CONSTRUCTION. PATCH AND REPAIR AS NEEDED AND PAINT PT-7 PER MALL REQUIRED SPECS. BOX BEAM. REFER TO STRUCTURAL, TYP. STOREFRONT BASE. REFER TO DETAIL. STOREFRONT GLASS GLAZING. ALL STOREFRONT GLASS SHALL BE TEMPERED PLATE GLASS WITH MAX. 1/8" JOINTS WITH CLEAR CAULK. NEW STOREFRONT COLUMN BEYOND. FINISHED PT-1 PER PLANS. REFER TO STRUCTURAL, TYP. BLOCKING AS REQUIRED, TYP. SALES AREA WALLS TO BE FINISHED PT-1 PER PLANS. LEASE LINE. STOREFRONT FINISH RECESSED AT HEADER, SO THAT GLAZING CAN BE FULLY RECESSED AND CONCEALED. SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80. MALL COMMON AREA FINISH FLOOR AREA TO BE PATCHED AND REPAIRED BY TENANT AS NECESSARY UP TO STOREFRONT. 2x 1/2" CEMENT BOARD OVER 3 5/8" 20 GA. METAL STUDS. SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80. 2x 1/2" CEMENT BOARD OVER 2 1/2" 20 GA. METAL STUDS. 6" 20 GA METAL STUD VERTICAL BRACING. REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATION, TYP. 5/8" TYPE "X" GYP. OVER 6" 20 GA. METAL STUD. #10-16 SS TEK SCREWS, TYP. PT-1 5/8" TYPE "X" GYP. OVER 6" 20 GA. METAL STUD. PT-1 2" GLAZING TOP CONNECTION, FINISH TO MATCH STOREFRONT SYSTEM, TYP. 6" 20 GA. METAL STUDS. ATTACHMENT TO 3 5/8" GA METAL STUD. REFER TO STRUCTURAL, TYP. ATTACHMENT TO EXISTING MALL BULKHEAD. REFER TO STRUCTURAL. B-1 TENANT FINISH FLOOR BOX BEAM. REFER TO STRUCTURAL, TYP. 3 5/8" 20 GA METAL STUD DIAGONAL BRACING @ 48" O.C. REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATION, TYP. EXISTING DECK TO REMAIN. ATTACHMENT TO BOTTOM OF DECK. REFER TO DETAIL AND STRUCTURAL DETAILS FOR MORE INFORMATION, TYP. EXISTING ROOF FRAMING TO REMAIN. PREPARE SURFACES FOR FINISHES, TYP. EXISTING MALL BULKHEAD TO REMAIN. PROTECT DURING CONSTRUCTION. PATCH AND REPAIR AS NEEDED AND PAINT PT-7 PER MALL REQUIRED SPECS. BOX BEAM. REFER TO STRUCTURAL, TYP. STOREFRONT BASE. REFER TO DETAIL. STOREFRONT GLASS GLAZING. ALL STOREFRONT GLASS SHALL BE TEMPERED PLATE GLASS WITH MAX. 1/8" JOINTS WITH CLEAR CAULK. NEW STOREFRONT COLUMN BEYOND. FINISHED PT-1 PER PLANS. REFER TO STRUCTURAL, TYP. BLOCKING AS REQUIRED, TYP. SALES AREA WALLS TO BE FINISHED PT-1 PER PLANS. LEASE LINE. STOREFRONT FINISH RECESSED AT HEADER, SO THAT GLAZING CAN BE FULLY RECESSED AND CONCEALED. SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80. MALL COMMON AREA FINISH FLOOR AREA TO BE PATCHED AND REPAIRED BY TENANT AS NECESSARY UP TO STOREFRONT. 2x 1/2" CEMENT BOARD OVER 3 5/8" 20 GA. METAL STUDS. SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80. 2x 1/2" CEMENT BOARD OVER 2 1/2" 20 GA. METAL STUDS. 6" 20 GA METAL STUD VERTICAL BRACING. REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATION, TYP. 5/8" TYPE "X" GYP. OVER 6" 20 GA. METAL STUD. #10-16 SS TEK SCREWS, TYP. PT-1 5/8" TYPE "X" GYP. OVER 6" 20 GA. METAL STUD. PT-1 2" GLAZING TOP CONNECTION, FINISH TO MATCH STOREFRONT SYSTEM, TYP. 6" 20 GA. METAL STUDS. ATTACHMENT TO 3 5/8" GA METAL STUD. REFER TO STRUCTURAL, TYP. ATTACHMENT TO EXISTING MALL BULKHEAD. REFER TO STRUCTURAL. B-1 TENANT FINISH FLOOR BOX BEAM. REFER TO STRUCTURAL, TYP. 3 5/8" 20 GA METAL STUD DIAGONAL BRACING @ 48" O.C. REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATION, TYP. SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80 ON WALL BEYOND. NEW STOREFRONT COLUMNS. REFER TO STRUCTURAL, TYP. 2X 1/2" CEMENT BOARD OVER 2 1/2" 20 GA. METAL STUDS. T.O. STOREFRONT 15' - 10" T.O. STOREFRONT 15' - 10" T.O. STUD 15'-4" T.O. STUD 15'-4" STOREFRONT SECTIONS AND DETAILS A302 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 22 2'-1" 9 STOREFRONT DETIAIL @ ENTRANCE 3/4" = 1'-0" 3'-0" 5 STOREFRONT DETIAIL 3/4" = 1'-0" 16'-0" 4 A303 6 1 / 2 " 2'-10" 3'- 2 " 3 A303 SIM. 3 A303 TENANT 6" 8" 3 A303 2' - 5 " 1'- 3 " 2' - 1 " 3' - 4 " 11" 1 3 / 8 " 3'-0" 2'-11" 7 7/8" 2' - 5 " 3' - 4 " 4 A303 SIM. 1'-11" 11" 3'-0" 12 A303 90 °90° 117° SECURITY GRILL AT OPENING AS SPECIFIED. LEASE LINE SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80. LINE OF HEADER ABOVE.STRUCTURAL COLUMNS. REFER TO STRUCTURAL, TYP. SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80. 5/8" TYPE "X" GYP. OVER 3 5/8" 20 GA. METAL STUD, TYP. STRUCTURAL COLUMN. REFER TO STRUCTURAL, TYP. 1/2" CLEAR TEMPERED GLASS LEASE LINE 1/2" CLEAR TEMPERED GLASS BLOCKING AS REQUIRED, TYP. LEASE LINE FINISH SEAM TO BE AT CENTER OF GLASS, TYP. FINISHES ARE TO ALINE AND BE AT CENTER OF GLASS. 1/2" CLEAR TEMPERED GLASS PT-1 OVER 5/8" TYPE "X" GYP. OVER 3 5/8" 20 GA. METAL STUD, REFER TO STRUCTURAL, TYP. BLOCKING AS REQUIRED BLOCKING AS REQUIRED, TYP. BLOCKING AS REQUIRED, TYP. LEASE LINE SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80, TYP. FINISHES ARE TO ALINE AND BE AT CENTER OF GLASS. 1/2" CLEAR TEMPERED GLASS 5/8" TYPE "X" GYP. OVER 3 5/8" 20 GA. METAL STUD. 2x 1/2" CEMENT BOARD OVER 3 5/8" 20 GA. METAL STUDS. REFER TO STRUCTURAL, TYP. 5/8" TYPE "X" GYP. OVER 2 1/2" 20 GA. METAL STUD.STRUCTURAL COLUMNS. REFER TO STRUCTURAL, TYP. PT-1 OVER 5/8" TYPE "X" GYP. OVER 2 1/2" 20 GA. METAL STUD. SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80. LEASE LINE FINISHES ARE TO ALINE AND BE AT CENTER OF GLASS. 1/2" CLEAR TEMPERED GLASS LINE OF SOFFIT ABOVE STRUCTURAL COLUMNS. REFER TO STRUCTURAL, TYP. EXISTING DEMISING WALL TO REMAIN. PATCH AND REPAIR AS NEEDED. FINISH MALL SIDE PT-6, PER MALL REQUIREMENT FINISH. EXISTING ADJACENT TENANT STOREFRONT TO REMAIN AS IS, N.I.S. 2x 1/2" CEMENT BOARD OVER 1 5/8" 20 GA. METAL STUDS. 2X 1/2" CEMENT BOARD OVER 3 5/8" 20 GA. METAL STUDS. PT-1 PT-1 2X 1/2" CEMENT BOARD OVER 2 1/2" 20 GA. METAL STUDS. BLOCKING AS REQUIRED, TYP. SF-1 2X 1/2" CEMENT BOARD OVER 3 5/8" X 20 GA. METAL STUDS. REFER TO STRUCTURAL, TYP. 2X 1/2" CEMENT BOARD OVER 3 5/8" 20 GA. METAL STUDS, TYP. PT-1 PT-1 OVER 5/8" TYPE "X" GYP. STRUCTURAL COLUMNS. REFER TO STRUCTURAL, TYP. EXISTING DEMISING WALL TO REMAIN. PATCH AND REPAIR AS NEEDED. FINISH MALL SIDE PT-6, PER MALL REQUIREMENT FINISH. LEASE LINE LINE OF SOFFIT ABOVE 1/2" CLEAR TEMPERED GLASS SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80.2X 1/2" CEMENT BOARD OVER 1 1/2" 20 GA. METAL STUDS. BLOCKING AS REQUIRED PT-1 OVER 5/8" TYPE "X" GYP. OVER 1 1/2" 20 GA. METAL STUD, TYP. PT-1 OVER 5/8" TYPE "X" GYP. PT-1 2X 1/2" CEMENT BOARD OVER 2 1/2" 20 GA. METAL STUDS. 1' - 2 3 / 4 " 13 STOREFRONT DETIAIL 3/4" = 1'-0" 2'-11" 8" 3 A303 8"2'-3" TYP. TYP. TYP. TYP. 14 STOREFRONT DETIAIL 3/4" = 1'-0" 8"2" 6" 8" 11 A303 TYP. PT-1 TYP. 8" LINE OF SOFFIT ABOVE LINE OF SOFFIT ABOVE 8" 8 " TENANT TENANT TENANT TENANTADJACENT TENANT ADJACENT MALL MALL MALL MALL PT-1 TYP. PT-1 TYP. PT-1 TYP. PT-1 TYP. SF-1 TYP. 117° STRUCTURAL COLUMNS. REFER TO STRUCTURAL, TYP. 11" 5" 2'-0"1'-8" LINE OF SOFFIT ABOVE, TYP. FILL THE GAP IN BETWEEN GLAZING WITH CLEAR CAULK. 2 GRILL GUIDE BASE DETAIL 3" = 1'-0" 8 STOREFRONT GLAZING JOINT, TYP. 3" = 1'-0" 1/8" 1/8 2-12 1/8 2-12 3 5/8" x 1 1/4" x 18 GA. CONTINUOUS METAL TRACK FASTENED WITH #10 SCREWS AT 12" O.C. SIMPSON S/H2.5 CLIP EA. SIDE. G.C. TO FILL ALL HOLES WITH #10 SCREWS. STRUCTURAL SUPPORT POSTS. SEE SPECIFIC DETAILS. 3 5/8" x 1 1/4" x 18 GA. CONTINUOUS METAL TRACK FASTENED WITH #10 SCREWS AT 12" O.C. STOREFRONT BEAM. REFER TO CHART BELOW. BOX BEAM DETAIL N.T.S. BOX BEAM SCHEDULE KEY SPAN SIZE B1 8'-0" - 11'-11"(2) 3-5/8"X1 5/8"X14 GA (2) 6"X1 5/8"X18 GA B2 12'-0" - 15'-11"(2) 8"X1 5/8"X18 GA B3 16'-0" - 19'-11"(2) 10"X1 5/8"X16 GA B4 20'-0" - 21'-11"(2) 12"X1 5/8"X14 GA B5 22'-0" - 23'-11"(2) 12"X1 5/8"X12 GA THIS DETAIL IS ONLY A DESIGN GUIDELINE AND SHALL BE REVIEWED FOR ACTUAL BEAM SIZE FOR EACH PROJECT. 10 4 GRILL GUIDE DETAIL 3" = 1'-0"1 STOREFRONT BASE DETAIL 3" = 1'-0"3 STOREFRONT JAMB DETAIL @ GLAZING 6" = 1'-0" 6 STOREFRONT HEAD DETAIL @ GLAZING 3" = 1'-0" 1' - 2 1 / 2 " TENANT 7 STOREFRONT HEAD DETAIL @ ENTRY 3" = 1'-0" EXISTING MALL FINISH. PATCH AND REPAIR AS NEEDED PER PLANS. SECURITY GRILLE LATCH MECHANISM. FLOORING, FINISH PER PLANS. GRILLE GUIDES RECESSED INTO WALL. INSTALL PER MANUFACTURE SPECS. WHERE INDICATED IN PLANS. ROLLING GRILLE HOUSING CENTERLINE OF ENTRY GRILLE BEYOND SEE STOREFRONT ELEVATION FOR GLASS JOINT LOCATIONS. 1/2" CLEAR TEMPERED GLAZING AS SPECIFIED IN ELEVATIONS. STOREFRONT BASE BELOW, REFER TO DETAIL 1/A302, TYP. CLADDED BASE SHOE, FINISH AS SPECIFIED, TYP. HORIZONTAL STOREFRONT MULLION SECTION. 1/4" HILTI KWK HUS EZ AT 18" O.C. 1/2"CLEAR TEMPERED GLASS. TENANT FLOORING PER PLANS EXISTING MALL FINISH. PATCH AND REPAIR AS NEEDED PER PLANS. SHIM AS REQUIRED. LINE OF RECESSED HEADER ABOVE, REFER TO SECTIONS. LEASE LINE 5/8" TYPE "X" GYP. OVER 3 5/8" 20 GA. METAL STUD, REFER TO STRUCT., TYP. SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80. BLOCKING AS REQUIRED, TYP. SECURITY GRILLE GUARD. REFER TO MANUFACTURE FOR INSTALL REQ., TYP. OPENING FOR SECURITY GRILLE, TYP. SECURITY GRILLE PER SPECIFICATIONS. LEASE LINE BASE BOARD, FINISH PER PLANS. CENTERLINE OF ENTRY GRILLE BEYOND. GRILLE AS SPECIFIED. FILL THE GAP IN BETWEEN GLAZING WITH CLEAR CAULK. BOX BEAM. REFER TO STRUCTURAL DRAWINGS, TYP. SF-1 ARMOURCOAT POLISHED PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80. CLEAR TEMPERED GLASS. GLAZING TOP CONNECTION TO BE FULLY RECESSED AND CONCEAL GLAZING, FINISH TO MATCH STOREFRONT SYSTEM, TYP. TENANT BASE BOARD PER PLANS STRUCUTRAL COLUMNS. REFER TO STRUCTURAL, TYP. LEASE LINE SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80. STRUCTURAL COLUMN. REFER TO STRUCTURAL, TYP. FINISHES ARE TO ALINE AND BE AT CENTER OF GLASS. 1/2" CLEAR TEMPERED GLASS 5/8" TYPE "X" GYP. OVER 3 5/8" 20 GA. METAL STUD, TYP. BLOCKING AS REQUIRED, TYP. PT-1 PT-1 PT-1 OVER 5/8" TYPE "X" GYP., TYP. LEASE LINE PT-1 OVER 5/8" TYPE "X" GYP. OVER 6" 20 GA. METAL STUD, SECURITY GRILLE GUARD. REFER TO ELEV. AND MFR. FOR INSTALL REQ., TYP. SF-1 ARMOURCOAT POLISHED PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80. LINE OF HEADER ABOVE, REFER TO SECTIONS. CORNER GUARDS, TYP. 6" 20 GA. METAL STUD OVER FINISH SPECIFIED. BLOCKING AS REQUIRED, TYP. SF-1 ARMOURCOAT POLISHED PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80.6" 20 GA. METAL STUD. 2 1/2" 20 GA. MTL. STUD. 2x 1/2" CEMENT BOARD OVER 3 5/8" 20 GA. METAL STUDS @ 16" O.C., TYP. 6" 20 GA. METAL STUD. 2 1/2" 20 GA. MTL. STUD. 2x 1/2" CEMENT BOARD OVER 3 5/8" 20 GA. METAL STUDS @ 16" O.C., TYP. BOX BEAM. REFER TO STRUCTURAL, TYP. 2X 1/2" CEMENT BOARD OVER 3 5/8" 20 GA. METAL STUDS. REFER TO STRUCTURAL, TYP. 2X 1/2" CEMENT BOARD OVER 3 5/8" 20 GA. METAL STUDS, TYP. 11 STOREFRONT JAMB DETAIL @ GLAZING 3" = 1'-0"12 STOREFRONT JAMB DETAIL @ GLAZING 3" = 1'-0" 1 3 / 8 " 1' - 3 " 2 1/2" 3/ 4 " 3/ 4 " 7 1 / 8 " ℄ TENANT TENANT TENANTMALL MALL MALL MALL TENANT MALLTENANT TENANT MALL 6" RECESS GYP. INTO SOFFIT TENANT MALL STRUCTURAL COLUMN. REFER TO STRUCTURAL, TYP. FINISHES ARE TO ALINE AND BE AT CENTER OF GLASS. 1/2" CLEAR TEMPERED GLASS. 5/8" TYPE "X" GYP. OVER 3 5/8" 20 GA. METAL STUD, TYP. BLOCKING AS REQ. PT-1 5/8" TYPE "X" GYP. OVER 2 1/2" 20 GA. METAL STUD, TYP. 5/8" TYPE "X" GYP. OVER 3 5/8" 20 GA. METAL STUD. LEASE LINE. LINE OF SOFFIT ABOVE. 5/8" TYPE "X" GYP. OVER 2 1/2" 20 GA. METAL STUD. BLOCKING AS REQIRED. SF-1 ARMOURCOAT POLISHED PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80. 8" 1/2" CLEAR TEMPERED GLASS SF-1 ARMOURCOAT POLISH PLASTER FINISH SPATULATA NATURAL WHITE P70 / P80. 2X 1/2" CEMENT BOARD OVER 1 1/2" 20 GA. METAL STUDS. STRUCTURAL COLUMNS. REFER TO STRUCTURAL, TYP. PT-1 OVER 5/8" TYPE "X" GYP. OVER 1 1/2" 20 GA. METAL STUD, TYP. EXISTING DEMISING WALL TO REMAIN. REFER TO DRAWINGS. LINE OF SOFFIT ABOVE. LEASE LINE BLOCKING AS REQUIRED. PT-1 OVER 5/8" TYPE "X" GYP., TYP. 1/8" FILL THE GAP IN BETWEEN GLAZING WITH CLEAR CAULK. FILL THE GAP IN BETWEEN GLAZING WITH CLEAR CAULK. FILL THE GAP IN BETWEEN GLAZING WITH CLEAR CAULK. 8 " STOREFRONT DETAILS A303 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 2 A D C B 1 ENLARGED MEN'S TOILET ROOM PLAN 1/2" = 1'-0" ADA TRAP GUARD B MOUNTING HEIGHTSACLEAR FLOOR SPACE MIRROR 5 LAVATORY DETAIL 1/2" = 1'-0" PAPER TOWEL DISPENSER TOILET PAPER DISPENSER AND SANITARY NAPKIN RECEPTACLE SEAT COVER DISPENSER WALL MOUNTED LAVATORY WATER CLOSET 6 TYPICAL MOUNTING HEIGHTS 1/2" = 1'-0" 7 - AUTOMATIC HAND DRYER TOILET TISSUE DISPENSER COAT HOOK / PURSE HOOK MIRROR (3) 14 X 2-1/2" TYPE 304 STAINLESS STEEL PHILLIPS ROUND-HEAD, SHEET METAL SCREWS 20 GA. TRACK SECURED TO STUDS 7 GRAB BAR DETAIL 1/2" = 1'-0" 1-1/2" DIA. STAINLESS STEEL GRAB BAR PARTITION AS SPECIFIED ACCESSIBLE SIGNAGE ADA SIGN DESCRIPTION MODEL#SIGNAGE WINDOW / COUNTER DECAL SYMBOL OF ACCESSIBILITY - SIZE: 6" X 6"ADA-1006 "EXIT" - SIZE: 6" X 6"; W/ ADA/CBC BRAILLE ADA-1242 "EXIT ROUTE" - SIZE: 6" X 6"; W/ ADA/CBC BRAILLE ADA-1243 WHEELCHAIR ACCESSIBLE ENTRANCE - SIZE: 6" X 8"ADA-1070 "ALL GENDER" WHEELCHAIR ACCESSIBLE RESTROOM - WALL - SIZE: 8" X 8"ADA-1026 "ALL GENDER" ACCESSIBLE RESTROOM - TACTILE BRAILLE - WALL - 8" X 9"ADA-1245 "ALL GENDER" WHEELCHAIR ACCESSIBLE RESTROOM - DOOR - 12" TRIANGLE / CIRCLE T24-1003 "ALL GENDER" WHEELCHAIR ACCESSIBLE RESTROOM - DOOR - 12' X 12"ADA-1251 G.C IS RESPONSIBLE FOR PROVIDING AND INSTALLING ALL ACCESSIBLE SIGNAGE. SIGNAGE TO BE ADA WHITE ON BLUE AVAILABLE FROM WWW.ADASIGNDEPOT.COM *NOT ALL USED AT THIS LOCATION ALL GENDERRESTROOM EXITROUTE ALL GENDERRESTROOM EXIT RESTROOM ENTRANCE 5'-0" TURNING DIA. 2 MEN'S TOILET ROOM ELEVATIONS 1/2" = 1'-0" A 1.DISPENSERS THAT CONTROL DELIVERY OR THAT DO NOT PERMIT CONTINUOUS PAPER FLOW SHALL NOT BE USED. 2.INTERIOR SURFACES - TOILET ROOM FLOORS SHALL HAVE A SMOOTH, HARD, NON-ABSORBENT SURFACE, SUCH AS PORTLAND CEMENT, CONCRETE, CERAMIC TILE, OR OTHER APPROVED MATERIALS WHICH EXTEND UPWARD ONTO THE WALLS AT LEAST 5". 3.THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES OR SINKS. 4.PROVIDE BLOCKING AT ALL WALL MOUNTED FIXTURES AND ACCESSORIES. 5.ALL EXISTNG FIXTURES TO REMAIN AND CONFIRM TO BE ADA COMPLIANCE. GENERAL NOTES B.O. CEILING 9'-0" T.O. FLOOR 0'-0" 4 WOMEN'S TOILET ROOM ELEVATIONS 1/2" = 1'-0"3 ENLARGED WOMEN'S TOILET ROOM PLAN 1/2" = 1'-0" B.O. CEILING 9'-0" T.O. FLOOR 0'-0" B C D A B C D B-3 FRP-1 PT-1 FRP-1PT-1 B-3 MIRROR B-3 FRP-1PT-1 B-3 FRP-1PT-1 B-3 FRP-1PT-1 B-3 B-3 SEAT COVER DISPENSER SEAT COVER DISPENSER MIRROR FRP-1 PT-1FRP-1PT-1 B-3 FRP-1 PT-1 ACCESSIBILITY SIGNAGE. SEE DETAIL 4 / G002 4 A D C B 5'-0" TURNING DIA. ACCESSIBILITY SIGNAGE. SEE DETAIL 4 / G002 30 " M I N . CL E A R FL O O R S P A C E 48" MIN. CLEAR FLOOR SPACE 1'- 3 " M I N . 9" M I N . 27 " M I N . 29 " M I N . 34 " M A X . 40 " M A X . TO R E F L E C T I V E SU R F A C E 11" MIN. KNEE CLEARANCE 6" MAX. TOE CLEARANCE 40 " M A X HI G H E S T O P E R A B L E PA R T O F A C C E S S O R Y 15 " M I N . 48 " M A X . 40 " M I N . TO P O F D I S P E N S E R 2' - 6 " 40 " M A X . TO T O P O F T H E H O O K 2' - 9 " TO T O P O F B A R 3' - 3 " 1' - 6 " 74 " M I N . 40 " M A X T O RE F L E C T I V E S U R F A C E 34 " M A X . TO T O P O F L A V A T O R Y 17 " M I N . 1 9 " M A X . TO T O P O F S E A T 40 " M A X TO D I S P E N S I N G AR E A 7' - 1 1 " 8'-0" 1'-0" MIN. 5' - 0 " C L E A R A N C E M I N . 9" M I N . 34 " M A X . 27 " M I N . 54" MIN. 12" MAX 42" MIN. 8" MIN. 2'- 6 " (3 0 " C L R . M I N . ) 1' - 6 " (1 8 " M I N . ) 4'-8" (56" MIN.) 3'-6" (42" MIN.) 3' - 0 " M I N . 3'-4" (32" MIN. CLEARANCE) 1' - 6 " (1 8 " M I N . ) 24" MIN. 4'- 1 0 " TO F R P 40 " M A X TO D I S P E N S I N G AR E A 11" MIN CLEAR 6" MAX CLEAR 36" MIN. 12" MIN. 24" MIN. 1 1 2" M I N . 3'-6" 40 " M A X 54" MIN. 12" MAX 24" MIN. 42" MIN. 7"-9" 19 " M I N . TO O P E N I N G 4'- 1 0 " TO F R P 4'- 1 0 " TO F R P 40 " M A X TO D I S P E N S I N G AR E A 11" MIN CLEAR 6" MAX CLEAR 54" MIN. 12" MAX 24" MIN. 42" MIN. 7"-9" 19 " M I N . TO O P E N I N G 36" MIN. 12" MIN. 24" MIN. 1 12" M I N . 3'-6" 40 " M A X 24" MIN. 1'-0" CLEAR 7' - 1 1 " 8'-0" 1'-0" MIN. 5' - 0 " C L E A R A N C E M I N . 2' - 6 " (3 0 " C L R . M I N . ) 1' - 6 " (1 8 " M I N . ) 4'-8" (56" MIN.) 3'-6" (42" MIN.) 3' - 0 " M I N . 3'-4" (32" MIN. CLEARANCE) 1' - 6 " (1 8 " M I N . ) 1'-0" CLEAR 3'-4" 3'-4 1/8" 6 7/8" MIN. TOILET LAVATORY 5 A561 5 A561 TYP. TYP. ENLARGED UNISEX TOILET ROOM A401 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 1 ENLARGED HALLWAY & STOCKROOM PLAN 1/2" = 1'-0" MW FRIDGE DSL LOCKERS HA R D W A R E B I N 24x48 24x48 LA D D E R S TRANSFORMER BA R B I N PR O C E S S I N G D E S K +4 2 " A . F . F . 24x48 24x48 24x48 24x48 24x48 24x48 EXISTING EXIT DOORS 3' - 0 " EQEQ HI LO 12" MIN. 1 CL CL CL 18" MIN. STOCK ROOM 5 6 8 9 111220 14 15 15 4 11 STDS @ 24" O.C. + 1 STD = 20'-0 1/4"7"7" 7" 10 4 4 4 4 EQ 3'-6"3'-6"EQ 2 2 2 A 44" CLEAR BUILD AISLE SHALL BE PROVIDED AND MAINTAINED THROUGH ROOMS TO EXIT DOORS FOR EGRESS. TENANT G.C. SHALL REPAIR OR REPLACE ALL DAMAGED FIRE-PROOFING WHEN APPLICABLE EMERGENCY LIGHTING SHALL BE PROVIDED WITH AN ILLUMINATION VALUE OF ONE FOOTCANDLE (MINIMUM) AT FLOOR LEVEL, THROUGHOUT EGRESS PATH. EXIT DOORS SHALL SWING IN THE DIRECTION OF EXIT TRAVEL WHEN SERVING AREAS WITH AN OCCUPANT LOAD OF 10 OR MORE PERSONS. DOORS OPENING INTO ONE-HOUR FIRE-RESISTIVE EXIT HALLWAY SHALL BE PROTECTED WITH A SMOKE OR DRAFT STOP FIRE ASSEMBLY HAVING A MIN. 20 MINUTE RATING EXIT SIGNS SHALL BE ELECTRICALLY ILLUMINATED AND THE TWO LAMPS SHALL BE ENERGIZED FROM SEPARATE CIRCUITS WITH 90 MINUTE BATTERY BACK-UP. ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES WIRING SYSTEM. IN THE EVENT OF FAILURE OF THIS SYSTEM, ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM AN EMERGENCY SYSTEM. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, TOOL OR SPECIAL KNOWLEDGE OR EFFORT. ALL DIMENSIONS ON PLANS ARE FROM FACE OF GYPSUM BOARD TO FACE OF GYPSUM BOARD UNLESS NOTED OTHERWISE. STOCKROOM NOTES KEYED NOTES NOTES 1 WALL MOUNTED HANDICAP ACCESSIBLE DRINKING FOUNTAIN. REFER TO SHEET G002. 2 BULLETIN BOARDS (3) - 36"W. X 48"H., BOTTOM OF BOARD TO BE MOUNTED @ 48" A.F.F. - COORDINATE LOCATIONS WITH STORE OPERATIONS 3 HALLWAY FRP WALL PANELS. SEE DETAIL 5/A561 4 METAL CORNER GUARDS - SEE DETAIL 6/A522. INSTALL ON COLUMNS AND ALL OUTSIDE CORNERS IN HALLWAY AND STOCK ROOM (SUPPLIED AND INSTALLED BY TENANT G.C.) 5 2A10BC FIRE EXTINGUISHER BY TENANT G.C. - TENANT G.C. TO COORDINATE EXACT LOCATIONS AND QUANTITIES WITH FIRE MARSHALL 6 BAR BIN, SEE DETAIL 7/A523 7 HARDWARE BIN, SEE DETAIL 8/A523 8 MANAGER'S SAFE. TENANT G.C. TO BOLT TO FLOOR, FACE OUTWARDS 9 MANAGER'S DESK WITH HEAVY DUTY STANDARDS AND SHELVES ABOVE 10 MANAGER'S FILE CABINET 11 CERTIFICATE OF OCCUPANCY FRAME. SEE ELEVATIONS 12 SHELF MOUNTED SOUND EQUIPMENT 13 LOCATION OF DSL RACK AND PHONE BOARD ON PLYWOOD BACKER 14 HEAVY DUTY SHELVING ON HEAVY DUTY SURFACE MOUNTED STANDARDS. STANDARDS @ 24" O.C. TYPICAL 15 STEP LADDER MOUNTED TO ROLLING SHELVING UNIT (2) LOCATIONS. MOUNTING HARDWARE SUPPLIED BY TENANT, INSTALLED BY TENANT'S G.C.. 16 ROLLING SHELVING UNIT. TENANT G.C. TO FLASH SKIM NEW OR EXISTING CONCRETE SLAB TO A MAXIMUM TOLERANCE OF 1/8" IN 10'-0" AT STORAGE 17 PROCESSING DESK WITH HEAVY DUTY STANDARDS AND SHELVES ABOVE. MIN 42" A.F.F. 18 EXISTING TRANSFORMER TO REMAIN. 19 LOCATION OF MOP SINK. 20 ELECTRICAL PANELS - SEE ELECTRICAL PLANS ## HALLWAY 3 T R A C K S A T 9 ' - 9 " 8 S T D S @ 2 4 " O . C . + 1 S T D = 1 4 ' - 5 " 7" 12 " MI N . 18 " MI N . 18 " MI N . 14 14 2' - 0 " 4" 18 3 7 HALLWAY 3 16 19 17 8 S T D S @ 2 4 " O . C . + 1 S T D = 1 0 ' - 0 " 5 S T D S @ 2 4 " O . C . + 1 S T D = 1 2 ' - 0 " 3' - 0 " 1' - 0 " 1' - 0 " 5'-3"3'-4"10" 9'-5" 7' - 6 " 4' - 6 " CL R . 3' - 8 " CL R . 3'-7 3/8" CLR. 5'-6 3/4" 3'-0" 3'-4 1/8"2'-10 3/8" 3' - 3 1 / 2 " 3 A523 3 A523 5 A523 2 A523 1 A523 4 A523 8 A523 7 A523 13 7" 7" 7" 7" 3' - 1 1 1 / 4 " ENLARGED HALLWAY & STOCKROOM A402 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 45° 15 ' - 0 " M A X . 8'- 0 " M A X . 20 ' - 0 " M A X . T O T A L S P A N 3" X 3" X 3" ANGLE (20 GA. MIN.), FASTENED TO TRACK AND BRACE PER DETAIL 'B' 20 GA. MIN. TRACK (PER ES REPORT ESR-1042) METAL STUDS, CUT 1/2" SHORT FOR 1/2" DEFLECTION AT SINGLE BRACE - FASTEN ANGLE TO BRACE WITH (3) NO. 8 SCREWS. AT DOUBLE BRACE - FASTEN DOUBLE BRACE TO BOTH ANGLES WITH (6) NO. 8 SCREWS THROUGH BRACE AND BOTH ANGLES AT SINGLE BRACE - FASTEN ANGLE TO TRACK WITH (4) NO. 8 SCREWS AT DOUBLE BRACE - FASTEN (2) ANGLES TO TRACK WITH (4) NO. 8 SCREWS AT EACH ANGLE FINISH MATERIALS VARY (MAX. WEIGHT EQUAL TO (2) LAYERS GYP. BD. EACH SIDE PLUS APPLIED FINISHES) FOR WALLS TO 10'-0" - BRACE WITH 362S137-33 AT 48" O.C. MAX. ALTERNATE DIRECTION OF BRACES ALONG LENGTH OF WALL WHERE POSSIBLE. FOR WALLS TO 15'-0" - BRACE WITH DOUBLED 362S137-33 AT 48" O.C. MAX. ALTERNATE DIRECTION OF BRACES ALONG LENGTH OF WALL. FASTEN DOUBLED STUDS TOGETHER WITH NO. 8 SCREWS AT 24" O.C. MAX. 45° 15 ' - 0 " M A X . 8'- 0 " M A X . 20 ' - 0 " M A X . T O T A L S P A N TOP OF WALL BRACING DETAIL 3" = 1'-0" 3" X 3" X 3" ANGLE (20 GA. MIN.), FASTENED TO TRACK AND BRACE PER DETAIL 'B' 20 GA. MIN. TRACK (PER ES REPORT ESR-1042) METAL STUDS, CUT 1/2" SHORT FOR 1/2" DEFLECTION AT SINGLE BRACE - FASTEN ANGLE TO BRACE WITH (3) NO. 8 SCREWS. AT DOUBLE BRACE - FASTEN DOUBLE BRACE TO BOTH ANGLES WITH (6) NO. 8 SCREWS THROUGH BRACE AND BOTH ANGLES AT SINGLE BRACE - FASTEN ANGLE TO TRACK WITH (4) NO. 8 SCREWS AT DOUBLE BRACE - FASTEN (2) ANGLES TO TRACK WITH (4) NO. 8 SCREWS AT EACH ANGLE A SECTION ACROSS PARTITION B SECTION ACROSS BRACING B A 3 - SIM. FINISH MATERIALS VARY (MAX. WEIGHT EQUAL TO (2) LAYERS GYP. BD. EACH SIDE PLUS APPLIED FINISHES) FOR WALLS TO 10'-0" - BRACE WITH 362S137-33 AT 48" O.C. MAX. ALTERNATE DIRECTION OF BRACES ALONG LENGTH OF WALL WHERE POSSIBLE. FOR WALLS TO 15'-0" - BRACE WITH DOUBLED 362S137-33 AT 48" O.C. MAX. ALTERNATE DIRECTION OF BRACES ALONG LENGTH OF WALL. FASTEN DOUBLED STUDS TOGETHER WITH NO. 8 SCREWS AT 24" O.C. MAX. 4 FASTENERS: AT PLYWOOD FLOOR (MIN. 3/4" CDX): PROVIDE (2) NO. 8 X 3/4" WOOD SCREWS AT 24" O.C. MAX. STAGGERED FOR (1) LAYER GYP. BD. EACH SIDE, 16" O.C. MAX. STAGGERED FOR (2) LAYERS GYP. BD. EACH SIDE. AT CIP CONCRETE FLOOR: PROVIDE HILTI X-DNI .145"Ø X 1" EMBED (POWDER-ACTUATED FASTENERS PER ES REPORT ESR-1663) AT 24" O.C. MAX. STAGGERED FOR (1) LAYER GYP. BD. EACH SIDE, 16" O.C. MAX. STAGGERED FOR (2) LAYERS GYP. BD. EACH SIDE. AT POST-TENSIONED CONCRETE FLOOR: PROVIDE HILTI X-DNI .145Ø X 3/4" EMBED (POWER-ACTUATED FASTENERS PER ES REPORT ESR-1663) AT 24" O.C. MAX. STAGGERED FOR (1) LAYER GYP. BD. EACH SIDE, 16" O.C. MAX. STAGGERED FOR (2) LAYERS GYP. BD. EACH SIDE. PARTITION FLOOR CONNECTION 3" = 1'-0" CONT 20 GA BOTTOM TRACK WITH HILTI' X-U SHOT PIN WITH 1 1/4" EMBEDMENT AT BOTTOM TRACK TO SECURE TRACK TO CONCRETE SLAB AT 24" O.C. (ICC ESR 2269) (INSTALL PER METAL FRAMING MANUFACTURER'S INSTALLATION MANUAL) #10 SCREW CONNECTION AT EACH STUD20 GA. MIN. TRACK AT ALL ACOUSTICAL PARTITIONS (PARTITIONS CONTAINING ACOUSTICAL INSULATION), APPLY A FILLET OF ACOUSTICAL SEALANT AT BOTTOM CORNER OF TRACK, EACH SIDE, PRIOR TO APPLICATION OF GYP. BD. 5 1" 2 ATTACHMENT TO STRUCTURE 3" = 1'-0" METAL STUDS FRAMING PER SECTIONS. LONG LEG RUNNER TRACK W/ 2" MIN. VERT. SLOTTED HOLES ATTACHED TO STRUCTURE. 3 5/8" X 20 GA. 'C' CHANNEL TRACK ATTACHED TO STUDS, FLOATING 1" BELOW TOP CORD IN DEEP 'C' CHANNEL. #12-24 TEK SCREWS @ EACH STUD. EXISTING ROOF FRAMING TO REMAIN. PREPARE SURFACES FOR FINISHES, TYP. DO NOT FASTEN TO ROOF / FLOOR DECK ABOVE. FASTEN TO THE TOP CORD OF THE BAR JOIST ONLY. REFER TO STRUCTURAL DETAIL 112/S3.1 FOR MORE INFORMATION, TYP. NEW STOREFRONT SOFFIT. 5/8" TYPE "X" GYP. BD. OVER 3 58" X 20 GA. METAL STUDS AT 16" O.C., TYP. EXISTING DECK/ ROOF TO REMAIN. (2) 3/8" HARDENED STEEL "U" BOLTS @ EACH CONN. EXISTING DECK ABOVE 1/4" STEEL PLATE @ EACH CONNECTION EXISTING BAR JOIST (VERIFY CONDITION) 20 GA DEEP LEG TRACK WITH 2" FLANGE. (DEPTH TO MATCH VERTICAL STUD DEPTH) ATTACH TO STRUCTURE WITH (2) 0.205" DIA. PAF OR (2) #12-24 TEK SCREWS @16" O.C. METAL STUDS AS SPECIFIED P1000 UNISTRUT @ 6'-0" O.C. ATTACH TO TOP CHORD OF EXISTING BAR JOIST (VERIFY CONDITION) STANDARD TRACK WITH (1) #8 WAFERHEAD SCREW IN EACH FLANGE OF EACH VERTICAL STD\UD 3/4" MAX 3/4" MAX 3/ 4 " DE F L . GA P ATTACHMENT TO STRUCTURE 3" = 1'-0" PROVIDE SINGLE HEAD TRACK AT SOFFIT CONDITIONS, AND PROVIDE DEEP LEG SLIP TRACK WITH 1/2" GAP AT FULL HEIGHT WALLS TO STRUCTURE 3 1 PARTITION TYPES 1 1/2" = 1'-0" NEW FULL HEIGHT WALL WITH GYP. BOARD ON BOTH SIDES: 3-5/8" 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYPSUM BOARD EACH SIDE TO BOTTOM OF DECK. B 5 A501 3 5/8" 20 GA. METAL STUD @ 16" O.C. WITH 5/8" TYPE "X" GYP. BOARD EACH SIDE. NEW BASE ON TENANT SIDE (ONLY WHERE OCCURS AS SPECIFIED). NEW FURRED WALL: -NEW FULL HEIGHT WALL FURRING -MAINTAIN INTEGRITY AND FIRE RATINGS OF EXISTING WALL. -FURRING = 3 5/8" METAL STUDS @ 24" O.C. -G.C. REFER TO SHEET A141 FOR STUD LAYOUT. 3 5/8" 20 GA. METAL STUDS @ 24" O.C. WITH 5/8" TYPE "X" GYP. BD. ON ONE SIDE A A1 5/8" TYPE "X" GYPSUM BOARD TO BOTTOM OF DECK NEW WALL WITH GYPSUM BOARD ON BOTH SIDES: 3 5/8" 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. TO 6" ABOVE CEILING ON ONE SIDE TO BOTTOM OF DECK. B1 5 A501 CEILING AS SPECIFIED. SEE RCP FOR CEILING HEIGHTS. BOTTOM OF EXISTING JOIST 5/8" TYPE "X" GYP. BD. TO BOTTOM OF DECK NEW WALL WITH GYPSUM BOARD ON BOTH SIDES: 3 5/8" 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. EACH SIDE TO 6" ABOVE CEILING. B2 5 A501 6" 5/8" GYP. BD. FULL HEIGHT TO BOTTOM OF DECK ON THIS SIDE NEW WALL WITH GYPSUM BOARD ON BOTH SIDES: 6" 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. EA SIDE TO 6" ABOVE CEILING B3 5 A501 6" NEW WALL WITH GYPSUM BOARD ON BOTH SIDES: 3 5/8" 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. EACH SIDE AND TOP OF WALL C 5 A501 8' - 0 " NEW PARTIAL HEIGHT WALL WITH GYP. BD. ON BOTH SIDES: 3 5/8" 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. EACH SIDE AND TOP OF WALL C1 5 A501 5' - 0 " NEW FULL HEIGHT WALL WITH GYP. BD. ON ONE SIDE: 6" 20 GA. METAL STUDS @ 16" O.C. FIRE RATED 5/8" TYPE "X" GYP. BD. D 5 A501 6" 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. TENANT SIDE ONLY 5/8" TYPE "X" GYP. BD. TO BOTTOM OF DECK TENANT SIDE ADJACENT TENANT SIDE FINISH BY ADJACENT TENANT NEW WALL WITH GYPSUM BOARD ON BOTH SIDES: 6" 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. ON ONE SIDE AND 3/4" CEMENT BOARD ON THE MALL SIDE. E 5 A501 TENANT SIDE MALL SIDE NEW BOTTOM TRACK. REFER TO DETAIL 5/A502. 3 A501 SIM. 3 A501 SIM. 3 A501 SIM. 3 A501 SIM. 3 A501 SIM. 3 A501 SIM. 3 A501 SIM. NEW BASE ON BOTH SIDES (ONLY WHERE OCCURS AS SPECIFIED). NEW BOTTOM TRACK. REFER TO DETAIL 5/A502. EXISTING DEMISING WALL OR EXTERIOR WALL TO REMAIN (V.I.F.) 3 5/8" 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. ON ONE SIDE TO 6" ABOVE CEILING. CEILING AS SPECIFIED 6" NEW BASE ON BOTH SIDES (ONLY WHERE OCCURS AS SPECIFIED). NEW BOTTOM TRACK. REFER TO DETAIL 5/A502. NEW BASE ON BOTH SIDES (ONLY WHERE OCCURS AS SPECIFIED). NEW BOTTOM TRACK. REFER TO DETAIL 5/A502. NEW BASE ON BOTH SIDES (ONLY WHERE OCCURS AS SPECIFIED). NEW BOTTOM TRACK. REFER TO DETAIL 5/A502. CEILING AS SPECIFIED CEILING AS SPECIFIED CEILING AS SPECIFIED. SEE RCP FOR CEILING HEIGHTS. CEILING AS SPECIFIED. SEE RCP FOR CEILING HEIGHTS. 3 5/8" 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. ON ONE SIDE TO 6" ABOVE CEILING. 3 5/8" 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. ON ONE SIDE TO 6" ABOVE CEILING. 6"6" NEW BASE ON BOTH SIDES (ONLY WHERE OCCURS AS SPECIFIED). NEW BOTTOM TRACK. REFER TO DETAIL 5/A502. NEW BASE ON BOTH SIDES (ONLY WHERE OCCURS AS SPECIFIED). NEW BOTTOM TRACK. REFER TO DETAIL 5/A502. NEW BASE ON TENANTSIDE (ONLY WHEREOCCURS AS SPECIFIED). NEW BOTTOM TRACK. REFER TO DETAIL 5/A502. NEW BOTTOM TRACK. REFER TO DETAIL 5/A502. 3 5/8" 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. 3 5/8" 20 GA. METAL STUD CAP WITH 5/8" TYP "X" GYP. BOARD FRP FINISH ON BOTH SIDES FINISH AS SPECIFIED, REFER TO PLANS NEW BASE ON TENANTSIDE (ONLY WHEREOCCURS AS SPECIFIED). FINISH AS SPECIFIED FINISH AS SPECIFIED, REFER TO PLANS 5/8" TYPE "X" GYP. BD. TO BOTTOM OF DECK 6" 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. TENANT SIDE ONLY CEMENTITIOUS BOARD 3 5/8" 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. 3 5/8" 20 GA. METAL STUD CAP WITH 5/8" TYP "X" GYP. BOARD NEW BASE ON TENANT SIDE (ONLY WHERE OCCURS AS SPECIFIED). NEW FURRED WALL: -NEW FULL HEIGHT WALL FURRING -MAINTAIN INTEGRITY AND FIRE RATINGS OF EXISTING WALL. -FURRING = 2 1/2" METAL STUDS @ 16" O.C. -G.C. REFER TO SHEET A141 FOR STUD LAYOUT. 2 1/2" 20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE "X" GYP. BD. ON ONE SIDE 5/8" TYPE "X" GYPSUM BOARD TO BOTTOM OF DECK NEW BOTTOM TRACK. REFER TO DETAIL 5/A502. 3 A501 SIM. EXISTING DEMISING WALL OR EXTERIOR WALL TO REMAIN(V.I.F.) B.O. (E) DECK B.O. (E) DECK B.O. (E) DECK B.O. (E) DECK B.O. (E) DECK B.O. (E) DECK B.O. (E) DECKB.O. (E) DECK 6 ATTACHMENT TO STRUCTURE 1 1/2" = 1'-0" (3) #10 TEK SCREWS. EA. CONN. CHANNEL NUT BEAM CLAMP UNISTRUT P5000 HS @ 6'-0" O.C. AFFIX TO TOP CHORD OF TRUSS W/ UNISTRUT BEAM CLAMPS AT EACH END. EXISTING ROOF DECK VERIFY EXACT CONDITION IN FIELD. 3-5/8" X 20 GA. MET. STUD SECTION ATTACHED TO UNISTRUT WITH (3) #10 SCREWS 3 5/8" X 20 GA. METAL STUD BRACING @ 48" O.C. CLIP AND BEND EXISTING TRUSS BEYOND. VERIFY EXACT CONDITIONS. PARTITION DETAILS A501 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/25/23 07/24/23 BUILDING COMMENTS 3 6' - 6 " 18 " 5'- 0 " 18 " 18 " 1' - 0 " 10 ' - 0 " S U R F A C E M O U N T E D W A L L S T A N D A R D 1' - 0 " 10 ' - 0 " S U R F A C E M O U N T E D W A L L S T A N D A R D HARDWARE BIN INSTALLED BY TENANT G.C. SEE DETAIL 8/A551. (SCREW TO BLOCKING) 1" X 4" FIRE TREATED POPLAR BLOCKING INSTALLED HORIZONTALLY BEHIND ALL WALL STANDARDS @ 24" O.C. (SECURE TO WALL STUDS) 3/4" X 16" DEEP WHITE MELAMINE SHELVING ON HEAVY DUTY SHELF BRACKETS. 10'-0" HEAVY DUTY WALL STANDARDS @ 48" O.C. MAX. CUT TO LENGTH AS REQUIRED. 1' - 6 " 1' - 6 " BAR BIN INSTALLED BY TENANT G.C. SEE DETAIL 7/A553 (SCREW TO BLOCKING) 10'-0" HEAVY DUTY WALL STANDARDS @ 48" O.C. MAX. CUT TO LENGTH AS REQUIRED. 3/4" X 16" DEEP WHITE MELAMINE SHELVING ON HEAVY DUTY SHELF BRACKETS. 1" X 4" FIRE TREATED POPLAR BLOCKING INSTALLED HORIZONTALLY BEHIND ALL WALL STANDARDS @ 24" O.C. (SECURE TO WALL STUDS) 1'- 6 " 1'- 6 " REFER TO RCP FOR CEILING 1 STOCK RM. SHELVING SECT. AT HARDWARE BIN 3/4" = 1'-0"2 STOCK ROOM SHELVING SECTION AT BAR BIN 3/4" = 1'-0" REFER TO RCP FOR CEILING 10 ' - 0 " S U R F A C E M O U N T E D W A L L S T A N D A R D 1' - 0 " 1' - 2 " 2' - 0 " 2' - 0 " 2' - 0 " 1' - 8 " 2'- 0 " 1" X 4" FIRE TREATED POPLAR BLOCKING INSTALLED HORIZONTALLY BEHIND ALL WALL STANDARDS @ 24" O.C. (SECURE TO WALL STUDS) 10'-0" HEAVY DUTY WALL STANDARDS @ 48" O.C. MAX. CUT TO LENGTH AS REQUIRED. 5'- 0 " 2'- 8 " 3' - 9 1 / 8 " 8' - 0 " S U R F A C E M O U N T E D W A L L S T A N D A R D 3' - 0 " MANAGER'S DESK PROVIDED BY TENANT AND ASSEMBLED AND INSTALLED BY G.C. (3 SCREWS MIN 2" LONG SECURED THROUGH TOP STRETCHER AT BACK INTO 1x4 BLOCKING) ELECTRICAL WORKBOXES (SEE ELECTRICAL DRAWINGS THIS SET) 3/4" X 16" DEEP WHITE MELAMINE SHELVING ON HEAVY DUTY SHELF BRACKETS. 6'-0" HEAVY DUTY WALL STANDARDS @ 48" O.C. MAX. CUT TO LENGTH AS REQUIRED. 1" X 4" FIRE TREATED POPLAR BLOCKING INSTALLED HORIZONTALLY BEHIND ALL WALL STANDARDS @ 24" O.C. (SECURE TO WALL STUDS) 1' - 6 " 1' - 6 " 1'- 6 " 1' - 6 " 1' - 0 " 2' - 0 " 2' - 0 " 2' - 0 " 2' - 0 " 6" MAX 4'-0" MAX (SEE PLAN)4'-0" MAX 6" MAX 1' - 0 " 10 ' - 0 " S U R F A C E M O U N T E D W A L L S T A N D A R D S 2' - 0 " 1" X 4" 18 GA METAL BLOCKING INSTALLED HORIZONTALLY BEHIND ALL WALL STANDARDS @ 24" O.C. (SECURE TO WALL STUDS) 94" HEAVY DUTY WALL STANDARDS @ 48" O.C. MAX. CUT TO LENGTH AS REQUIRED. 3 STOCK ROOM WALL BLOCKING SECTION 3/4" = 1'-0" REFER TO RCP FOR CEILING 4 MANAGER'S DESK SECTION 3/4" = 1'-0" 6 STANDARDS ELEVATION AT STOCK ROOM 3/4" = 1'-0" REFER TO RCP FOR CEILING 3' - 2 " 3' - 2 " 3' - 2 " 1' - 0 " 10 ' - 0 " S U R F A C E M O U N T E D W A L L S T A N D A R D 1' - 0 " HANGROD BRACKET WITH SADDLE END, HEAVY DUTY HANGROD, AND END CAPS. 10'-0" HEAVY DUTY WALL STANDARDS @ 48" O.C. MAX. CUT TO LENGTH AS REQUIRED. 1" X 4" FIRE TREATED POPLAR BLOCKING INSTALLED HORIZONTALLY BEHIND ALL WALL STANDARDS @ 24" O.C. (SECURE TO WALL STUDS) 5 STOCK ROOM HANGROD SECTION 3/4" = 1'-0" REFER TO RCP FOR CEILING THE UPRIGHTS ATTACH TO THE WOOD BLOCKING WITH 2 #8 X 1 1/2” WOOD SCREWS (THIS WOULD BE AT EACH UPRIGHT AT EACH ROW OF BLOCKING) THE WOOD BLOCKING 1X4 ATTACHES TO EACH METAL STUD WITH 2 #8 SCREWS. EACH BLOCKING SHOULD ATTACH TO 3 STUDS MINIMUM. (TYP) REFER TO RCP FOR CEILING 2'-0" MAX2'-0" MAX2'-0" MAX2'-0" MAX OUTRIGGER ATTACHMENT TO WALL NO SCALE (4) 3/8" DIA WITH 7 3/8" NOMINAL EMBEDMENT HILTI HY270 ADHESIVE ANCHORS WITH HIT-SC SLEEVES. 5" X 5" PLATE PER MANUFACTURE SECTION .67" MINIMUM CLEARANCE (TYP.) PLATE ELEVATION NOTE: TENANT G.C. TO ENSURE OUTRIGGERS ARE LASER LEVELED TO ENSURE NOT ONLY THE BOTTOM AND TOP ALIGN, BUT ALSO THAT THE SLOTS ALIGN ACROSS ALL OUTRIGGERS. 5/8" TYPE "X" GYP. BD. WALL PER PLANS (4) 3/8" DIA WITH 7 3/8" NOMINAL EMBEDMENT HILTI HY270 ADHESIVE ANCHORS WITH HIT-SC SLEEVES. 5" X 5" PLATE PER MANUFACTURE 11 NOTE: FIXTURES PROVIDED BY OWNER VENDOR 4'-0" MAX (SEE PLAN) 4'-0" MAX (SEE PLAN) 7" 7' - 1 1 " OUTRIGGER ELEVATION AT SALES 3/4" = 1'-0" 3' - 5 " 5"X5" MOUNTING BRACKETOUTRIGGERS PER MFR. (2) 2x4 FIRE TREATED WOOD BLOCKING. 11 ' - 4 " 10 4" EXISTING DEMISING WALL 11'-11" A.F.F. OUTRIGGER SECTION AT SALES 3/4" = 1'-0" 8'-6" A.F.F. 0'-7" A.F.F. TENANT G.C. SHALL PROVIDE AND INSTALL SOUND ATTENUATION BATT INSULATION IN STUD CAVITIES WHEN SPACE OPPOSITE DEMISING WALL IS OCCUPIED BY RETAIL TENANT 5"X5" MOUNTING BRACKET (2) 2x4 FIRE TREATED WOOD BLOCKING. SCREW MOUNTING BRACKET TO BLOCKING. TYP 11 - 6" OUTRIGGER PER MANUFACTURE 1" 5" 9 NOTES: 1.THIS BLOCKING IS FOR ELEMENTS WITH A MAXIMUM VERTICAL LOAD OF 100 LBS PER LINEAR FOOT AT A MAXIMUM OF 7" FROM THE FACE OF WALL. 2.REFER TO INDIVIDUAL DETAILS AND MFG INSTALLATION INSTRUCTIONS FOR REQUIRED SCREW TYPE TO ATTACH ITEMS TO BLOCKING. WHEN NOT SPECIFICALLY INDICATED USE MIN. #8 SELF TAPPING SHEET METAL SCREWS. 48" O . C . MAX. T Y P . METAL STUD FRAMING PER PLAN. HORIZONTAL METAL STANDARDS DETAIL AT SALES 3/4" = 1'-0" NOTCH TRACK AT EA. VERTICAL STUD ATTACH TO EACH STUD WITH (3) #8 PAN HEAD SCREWS 6" X 18 GA. BACKING TRACK. LENGTH AS REQUIRED FOR INDIVIDUAL ELEMENTS. REFER TO SPECIFIC DETAILS 1617NOT USED 3/4" = 1'-0" STANDARDS DETAIL AT STOCK ROOM 3/4" = 1'-0" 12"12"12"12"12"12"12"10" 1. 7 5 " 1.50" 95.50" 1. 7 5 " 95.50" 1.50 2" .8 7 5 " 1.975" .7 5 0 " 1.05" .1 8 0 " .4 1 0 " 1. 5 0 " 1.75" .125" GRIND CUT EDGES & RE-POWDER COAT TOPBOTTOM 13 12 NOT USED 3/4" = 1'-0" 14 NOT USED 3/4" = 1'-0"15 NOT USED 3/4" = 1'-0" 17 1/ 2 " 4'- 9 1 / 2 " 4' - 0 " MOUNTING FLUSH TO WALL STANDARDS: SCREW BACKSIDE OF UNIT SECURELY TO HORIZONTAL WOOD FURRING OR WALL STUDS ALONG TOP AND MIDDLE OF UNIT 7 BAR BIN DETAIL @ STOCKROOM 3/4" = 1'-0" NOTE: THIS UNIT IS PROVIDED BY TENANT, TENANT G.C. TO INSTALL. 4' - 1 0 " 17 1 / 2 " 4'-4" 8 HARDWARE BIN @ STOCKROOM 3/4" = 1'-0" NOTE: THIS UNIT IS PROVIDED BY TENANT, TENANT G.C. TO INSTALL. MOUNTING FLUSH TO WALL STANDARDS: SCREW BACKSIDE OF UNIT SECURELY TO HORIZONTAL WOOD FURRING OR WALL STUDS ALONG TOP AND MIDDLE OF UNIT 7 A502 8 A502 SALES & STOCK ROOM SECTIONS AND DETAILS A502 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 HOOK DETAIL @ FITTING ROOM 3/4" = 1'-0" 16 " 16 " 16" ELEVATION VIEWPLAN VIEW 4' - 0 " A . F . F . ( H . C . FI T T I N G R M ) 5'- 0 " A . F . F . ( S T D FI T T I N G R M ) SECTION VIEW 5/8" TYPE "X" GYP. BD. OVER 3-5/8" X 20 GA. METAL STUDS @ 16" O.C. BY TENANT G.C. 5/8" TYPE "X" GYP. BD. OVER 3-5/8" X 20 GA. METAL STUDS @ 16" O.C. BY TENANT G.C. HEAVY DUTY HOOK AS SPECIFIED. SCREW TO WALL WITH SUPPLIED FASTENERS. TYP. OF (3). 2" X 6" WOOD BLOCKING IN WALL FOR ATTACHMENT OF HOOKS. HEAVY DUTY HOOK AS SPECIFIED. SCREW TO WALL WITH SUPPLIED FASTENERS. TYP. OF (3). 2" X 6" WOOD BLOCKING IN WALL FOR ATTACHMENT OF HOOKS. HEAVY DUTY HOOK AS SPECIFIED. SCREW TO WALL WITH SUPPLIED FASTENERS. TYP. OF (3). 2" X 6" WOOD BLOCKING IN WALL FOR ATTACHMENT OF HOOKS. 4'- 0 " A . F . F . ( H . C . FI T T I N G R M ) 5'- 0 " A . F . F . ( S T D FI T T I N G R M ) 16" 1J-CHANNEL DETAIL @ MIRROR 3/4" = 1'-0" J CHANNEL BY G.C. WALL FASTENERS MIRROR J CHANNEL BY G.C. WALL FASTENERS MIRROR WALL WALL MIRRORS ARE TO HAVE ANTI-GRAFFITI FILM FINISH APPLIED TO SURFACES PER RESPONSIBILITY MATRIX. 2 24" @ H.C. ROOM 13 1 / 2 " 18 " A . F . F . 4 1 / 2 " 14 1 / 2 " 3/4" F.R.T. PLYWOOD BLOCKING (TENANT G.C. SHALL USE 16 GA. METAL BLOCKING IF LOCAL A.H.J. DOESN'T PERMIT WOOD BLOCKING) TENANT G.C. SHALL INSTALL IN-WALL BLOCKING AT SCREW LOCATIONS (VERIFY EXACT LOCATIONS OF FASTENERS WITH VENDORS INSTALLATION INSTRUCTIONS LINE OF TENANT'S FINISHED FLOOR ADA BENCH SECTION @ FITTING ROOM 3/4" = 1'-0" FITTING ROOM BENCH PROVIDED BY TENANT AND INSTALLED BY TENANT'S G.C. GROUND FLOOR SLAB +0'-0" INTERIOR PARTITION AS SPECIFIED. 3BENCH SECTION @ FITTING ROOM N.T.S. 16" 13 1 / 2 " 18 " A . F . F . 4 1 / 2 " 14 1 / 2 " 3/4" F.R.T. PLYWOOD BLOCKING (TENANT G.C. SHALL USE 16 GA. METAL BLOCKING IF LOCAL A.H.J. DOESN'T PERMIT WOOD BLOCKING) TENANT G.C. SHALL INSTALL IN-WALL BLOCKING AT SCREW LOCATIONS (VERIFY EXACT LOCATIONS OF FASTENERS WITH VENDORS INSTALLATION INSTRUCTIONS LINE OF TENANT'S FINISHED FLOOR FITTING ROOM BENCH PROVIDED BY TENANT AND INSTALLED BY TENANT'S G.C. GROUND FLOOR SLAB +0'-0" INTERIOR PARTITION AS SPECIFIED. 4 CORNER GUARD DETAIL @ SALES 3/4" = 1'-0" CAULK AROUND ALL EDGES OF CORNER GUARD WITH CLEAR SILICONE (TYP.) 48" x 1 1/2" x 1 1/2" - 90°, 16ga, TYPE 304, CLEAR FINISH, NSF CERTIFIED, CLEAR CORNER GUARD WITH ROUNDED CORNERS. PROVIDED AND INSTALLED BY TENANT G.C. 1 1/2" 1 1 / 2 " CORNER GUARDS TO BE INSTALLED WITH LIQUID NAILS IN SALES. INTERIOR PARTITION AS SPECIFIED. 6CORNER GUARD DETAIL @ NON-SALES N.T.S. CORNER GUARDS TO BE INSTALLED WITH LIQUID NAILS IN HALLWAY. INSTALL W/ GLUE AND #6 SELF-TAPPING DRYWALL SCREWS @18" O.C. IN STOCK AREA CAULK AROUND ALL EDGES OF CORNER GUARD WITH CLEAR SILICONE (TYP.) 48" X 1 1/2" X 1 1/2" - 90°, 16GA, TYPE 304, STAN #4 FINISH, NSF CERTIFIED, METAL CORNER GUARD WITH ROUNDED CORNERS. PROVIDED AND INSTALLED BY TENANT G.C. 1 1/2" 1 1 / 2 " INTERIOR PARTITION AS SPECIFIED. 7 7' - 6 " 9'-5" EQ.EQ. 18 " LOCATION OF DELIVERY BUZZER 8" EMPLOYEE SIDE OF CUSTOM CASHWRAP FIXTURE BY OWNER. 11'-2"W X 2'-8" CUSTOM BACKWRAP FIXTURE BY OWNER. 98-1/2"W X 34"H LOCATION OF ELECTRICAL OUTLET 18" A.F.F. AND 8" FROM CORNER OF BACKWRAP. TO ELECTRICAL DRAWINGS FOR MORE INFO. 5' - 1 " BACKLIT LED SIGNAGE BY TENANT. CENTERED ABOVE BACKWRAP. REFER TO DETAIL 8/A503 AND ELECTRICAL DRAWINGS FOR MORE INFORMATION. ℄ ℄ ℄ ℄ 34 " 8 1 / 2 " BACK WRAP ELEVATION DETAIL - SIGNAGE 3/4" = 1'-0"5EDGE-LIT ARCRYLIC LETTERS - END VIEW FOR REFERENCE ONLY FOR REFERENCE ONLY: REFER TO ELECTRICAL DRAWINGS AND SIGN PACKAGE BY OTHERS FOR MORE INFORMATION. REMOTE-WIRED POWER SUPPLY ON PLASTIC RETURN 3/4" 1/2" 1/2"WALL PENETRATIONS TO BE SEALED, TYP. SPACER 3/16" INTERIOR FITTED ALUM. BAFFLE PAINTED ACRYLIC F ACE ACRYLIC BACK LED TAP ILLUMINATION LOW VOLTAGE LED WIRE ELECTRICAL GROUNDING UL LISTED FITTINGS/CONNECTORS TRIM-CAP ADHESIVE COVER SCREW WIRE NUT ON / OFF SWITCH JUNCTION BOX POWER SUPPLY PRIMARY POWER NOTES: ·THE SIGN LETTERS ARE TO BE INDIVIDUALLY WIRED. ·THE ELECTRICAL IS RUN THROUGH A 1/2” HOLE, MOUNTING IS AT 1/4”. ·120V ELECTRICAL. ·SIGNAGE INSTALLERS WILL RUN WIRING UNDER 6'. G.C TO PROVIDE ELECTRICAL RUN TO THE BACK OF THE WALL. 8 SECTIONS AND DETAILS A503 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 BLOCKING AT PENDANT LIGHT N.T.S. DO NOT ATTACH TO METAL DECK OR BOTTOM CHORD OF TRUSSES. ATTACH TO EXISTING TOP CHORD OF TRUSSES PER CISCA 0-2 UNISTRUT SYSTEM OR TOP CHORD OF TRUSSES 3 #12 WIRES AT EACH CORNER 5/8" FRT PLYWOOD #8 SCREWS AT 12" O.C. MAX. PENDANT FIXTURE BELOW 5/8" FRT PLYWOOD 1 24" ROUGH OPENING 1'-6" ACCESS OPENING ACCESS PANEL MANUFACTURED BY: INTEX FORMS INC, (510) 887-8000 18" x 18" GFRG FIBERGLASS ACCESS PANEL, 12"X12" GFRG FIBERGLASS ACCESS PANEL. NOTE: THIS ACCESS PANEL IS NOT TO BE USED IN FIRE-RATED LOCATIONS. PUSH OUT ACCESS PANEL N.T.S. FILL, TAPE AND SAND SMOOTH AT JOINT BETWEEN FRAME AND DRYWALL, TYP. ACCESS PANEL FRAME, BY MFR. 18" X 18" FIBERGLASS DROP-IN DOOR PANEL3 5/8" METAL STUD FRAMING SHEET METAL SCREW, TYP. CENTERLINE OF METAL STUD BLOCKING ABOVE, TYP. 3 FASTEN TO STEEL FRAMING, WOOD FRAMING, CONCRETE STRUCTURE, CONCRETE DECK, OR STEEL DECK PER ES REPORT ER-4071 (PARA 2.2.2.) OR PER CISCA 3-4 (FIGURES 2, 3, 4, AND 5) STEEL STUDS - G.C. TO DETERMINE SPACING STEEL STUD5/8" GYP. BD. * * LENGTH OF DIAGONAL WALLS WHERE DIAGONAL IS ATTACHED TO TOP OF WALL SPACING OF DIAGONAL BRACING INTERIOR PARTITIONS - 72" O.C. MAX STOREFRONT FRAMING - 48" O.C. MAX AT DIAGONAL, ATTACH TRACK TO WALL STUD w/(2)-#8 SCREWS EACH SIDE.1 1 NOTE: FOR DOUBLE STUD DIAGONALS, "SECOND" STUD SHALL END AS CLOSE AS POSSIBLE TO END CONNECTION, TOP & BOTTOM. (4)-#8 SCREWS WALL OR STOREFRONT STUD. CONNECT TRACK TO VERT STUDS W/(1)-#8 SCREW IN EACH FLANGE OF EACH STUD, EXCEPT INSTALL (2)-#8 SCREWS IN EACH FLANGE AT VERT STUDS WITH DIAGONALS CONTINUOUS TRACK (GAGE TO MATCH WALL STUD, EXCEPT USE 20 GAGE MIN TRACK) CONNECT TO EXISTING STRUCTURE PER DETAIL S/A700 VIEWS A-A B-B & C-C 2"x2"x0'-6" LG, 12 GA FRAMING CLIP W/(3)-#8 SCREWS EA LEG CONTINUOUS TRACK (GAGE TO MATCH WALL STUD, EXCEPT USE 20 GAGE MIN TRACK) CENTER DIAGONAL OVER VERTICAL STUD 1 1/4"1 1/4" DBL 3 5/8", 20 GA. STUDS WITH 1 1/4" WIDE FLANGES 1 1/4"1 1/4" DBL 3 5/8", 20 GA. STUDS WITH 1 1/4" WIDE FLANGES w/CONTINUOUS 3 5/8" TRACK TOP & BOTTOM. #8 SCREWS @ 12"c/c #8 SCREWS @ 12"c/c 1 1/4" 3 5/8", 20 GA. STUDS WITH 1 1/4" WIDE FLANGES VIEW A-A VIEW B-B VIEW C-C DIAGONAL LENGTH- UP TO 7'-6" DIAGONAL LENGTH- 7'-7" TO 16'-6" DIAGONAL LENGTH- 16'-7" TO 20'-0"* 20 GA. DIAGONAL BRACING OPTIONS 2 TYPICAL DIAGONAL BRACING - SEISMIC DESIGN CATEGORIES A & B USING GRID SUSPENSION SYSTEM 4 BANNER TRACK SECTION AT SALES 1" = 1'-0" CEILING MOUNTED BANNER TRACK IN DISPLAY AREA (TENANT G.C. TO PROVIDE AND INSTALL 6" WIDE CONT. 18ga BLOCKING FULL LENGTH OF IMAGE TRACKS AND SECURE WITH #10 1-1/2" SCREWS AT STUD LOCATIONS) 6"6" 5 INSTALLATION OF STEEL STUD FRAMING USING GRID SUSPENSION SYSTEM8SUSPENDED CEILING BRACING 1" = 1'-0"7 GYP TO OPEN CEILING SECTION @ HEADER 1" = 1'-0" BOTTOM OF DECK METAL STUD FRAMING CORNER GUARD FOR HEADER EDGE, TYP. LINE OF WALL BEYOND METAL TRACK SCHEDULED GYP CEILING BOTTOM OF DECK METAL STUD FRAMING METAL TRACK SCHEDULED GYP CEILING NOTE: FASTENING TO STRUCTURE ABOVE TO COMPLY WITH LANDLORD AND OR LOCAL BUILDING DEPARTMENT REQUIREMENTS.ALL IBC SEISMIC CATEGORIES 8" MA X AT P E R I M E T E R HEAVY DUTY SUSPENDED MAIN BEAM @ 4'-0" O.C. ANGLE WALL MOLDING. MINIMUM OF 3 TIGHT TURNS AT ALL WIRES. 5/8" GYP. BD.NOTE: REFER TO CEILING PLAN FOR ALL CEILING HEIGHTS. 12 GA VERTICAL SUPPORT WIRE @ 4'-0" O.C. EA. WAY. AND MAX. 8" FROM ALL EDGES. HEAVY DUTY SUSPENDED CROSS TEE @ 2'-0" O.C. 6 SUSPENDED GYP. BD. CEILING N.T.S. 45° MAX 45° MAX 2" MAX 45° MAX B.O. CLNG. REFER TO RCP 12 GA VERTICAL SUPPORT WIRE @ 4'-0" O.C. EA. WAY. AND MAX. 8" FROM ALL EDGES. B.O. CLNG. REFER TO RCP SCHEDULED GYP CEILING 12 GA VERTICAL SUPPORT WIRE @ 4'-0" O.C. EA. WAY. AND MAX. 8" FROM ALL EDGES. B.O. CLNG. REFER TO RCP 6 A504 TYP. 9 OPEN TO OPEN CEILING SECT. @ HEADER 1" = 1'-0" BOTTOM OF DECK METAL STUD FRAMING CORNER GUARD FOR HEADER EDGE, TYP. LINE OF WALL BEYOND METAL TRACK B.O. CLNG. REFER TO RCP B.O. HEADER 7'-0" G.C SHALL INSTALL SUSPENDED BOARD CEILINGS IN COMPLIANCE WITH ICC ESR 1289. SUSPENDED CEILING. ELEVATION PLAN FINISH FLOOR COMPRESSION STRUTS @12'-0" O.C. EA. WAY 3/8" MIN. CLEAR CROSS RUNNER OR MAIN RUNNER. TIE TWO ADJACENT WALL TO CEILING MAIN AND CROSS RUNNERS 8" 4'-0"12'-0" MAX. 4'-0" MIN12 ' - 0 " 4' - 0 " 8" MIN. 12 GAUGE WIRES. FI N . C L G . H G T . 8" 10 - 4 5 ° 10 SUSPENDED CEILING BRACING 1" = 1'-0" 3" 34" M I N . EXISTING STRUCTURE FIRE SAVING INSULATION IN "RIB" OF METAL DECK. DEEP LEG DEFLECTION OR SLIP TRACK. METAL TOP CHANNEL MTL. STUDS AT 16" O.C. REFER TO FLOOR PLAN. 5/8" FIRE-CODE GYP. BD. COVER. 5/8" FIRE-CODE GYP. BD. WALL FACING. 13 1-HOUR FULL HEIGHT SLIP JOINT AT DECK 1" = 1'-0" 362 CJS 20 VERTICAL STRUT AT 8'-0" O.C. MAX. EACH WAY WITH FIRST STRUT TO BE WITHIN 4'-0" OF EACH WALL FASTENED TO MAIN RUNNER AND NEW TRACKS THAT SPAN BETWEEN ANY EXISTING BASE-BUILDING STRUCTURAL BEAMS ONLY. 2" M A X . 2" 45 ° 45 ° C.L . 362 CJS 20 VERTICAL STRUT 4'-0" EACH WAY (TYP.) 250 S 137-33 DIAGONAL BRACING (TYPICAL) 362 CJS 20 @ 16" O.C. CEILING MAIN RUNNERS 362 CR 20 @ 48" O.C. CROSS RUNNERS (LAID FLAT) EMT TIGHT TO NEW TRACKS THAT SPAN BETWEEN ANY EXISTING BASE-BUILDING STRUCTURAL BEAMS ONLY. 12 GA. VERTICAL HANGER WIRE COMPRESSION STRUT REQUIRED @EACH SEISMIC RESTRAINT, 12' O.C. EACH WAY. 3/4" EMT NOTCH OVER MAIN RUNNER 45° 4 5 ° 45 ° CROSS FURRING CHANNEL SCREW TO MAIN BEAM W/ #8 BUGLE HEAD SCREWS- MIN. 1/4" THROUGH METAL FRAMING AND SECURE ENDS TO WALL ANGLES WITH POSITIVE ATTACHMENT. SEE ALSO SPECIFICATION SHEET AS02 AND USG TYPICAL INSTALLATION 5/8" TYPE 'X' GWB. ATTACHED TO CEILING FRAMING W/ #8 BUGLE HEAD SCREWS @ 12" O/C- MIN. 1/4" THROUGH METAL FRAMING DRILL 5/32" HOLE FOR 1/8" BOLT & LOCK NUT AFTER CEILING IS LEVELED. NOTE: INSTALL BRACING AT 12'-0" O.C. EA. WAY AND WITHIN 4'-0" OF PERIMETER WALLS 4" M I N . L A P WALL CONDITION SUSPENDED CEILING NOTES: 1.ALL HANGER & BRACING WIRES SHALL BE SECURED TO MAIN RUNNERS. 2.FURNISH TRAPEZE OF OTHER SUPPLEMENTARY SUPPORT MEMBERS AT OBSTRUCTIONS TO MAIN HANGER SPACING. FURNISH ADDITIONAL HANGERS, STRUTS, OR BRACES AS REQUIRED AT ALL CLG. BREAKS, SOFFITS, OR DISCONTINUOUS AREAS. HANGER WIRES THAT ARE MORE THAN 1 IN 6 OUT OF PLUMB ARE TO HAVE COUNTER-SLOPING WIRES. PERIMETER WIRES: 12 GAUGE PERIMETER WIRES INSTALLED WITHIN 8" OF WALL AT EACH MAIN AND CROSS TEE TO WALL JUNCTURE ALL WIRES SHALL BE TAUT & TIED @ BOTH ENDS W/ (3) TURNS IN 1" OF RUN. SUSPENSION SYSTEM FRAME COMPONENTS: - 20 GA. FURRING HAT CHANNELS 24" O.C. - 1 1/2" X 16GA. COLD ROLLED CHANNELS 48" O.C. - GALV. WIRE METAL FURRING CLIPS., (CHANNEL TO CHANNEL) MAIN SUPPORTS: 12 GAUGE HANGER WIRES AT 4'-0" O.C. EACH WAY ALL WIRES SHALL BE TAUT & TIED @ BOTH ENDS W/ (3) TURNS IN 1" OF RUN GYP. BD FINISH: - 5/8" TYPE "X" GYP. BD. 12 SEISMIC SUSPENDED GYPSUM WALL BOARD CEILING 1/4" = 1'-0"11 SUSPENDED GYPSUM WALL BOARD CEILING DETAIL 1/4" = 1'-0" NOTE: ATTACHMENTS TO THE DECK PAN ABOVE IS STRICTLY PROHIBITED; ATTACHMENTS TO NEW TRACKS THAT SPAN BETWEEN ANY EXISTING BASE-BUILDING STRUCTURAL BEAMS ONLY. GC TO VERIFY ALL CEILING ATTACHMENT COMPLIANCE WITH MALL PRIOR TO INSTALLATION. NOTE: ATTACHMENTS TO THE DECK PAN ABOVE IS STRICTLY PROHIBITED; ATTACHMENTS TO NEW TRACKS THAT SPAN BETWEEN ANY EXISTING BASE-BUILDING STRUCTURAL BEAMS ONLY. GC TO VERIFY ALL CEILING ATTACHMENT COMPLIANCE WITH MALL PRIOR TO INSTALLATION. G.C SHALL INSTALL SUSPENDED BOARD CEILINGS IN COMPLIANCE WITH ICC ESR 1289. CEILING DETAILS A504 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 2 22 2 2 2 7 FLOOR DETAIL AT SERVICE DOOR 6" = 1'-0" CENTERLINE OF DOOR OPENING EXISTING CORRIDOR DOOR EXISTING CORRIDOR FLOORING DOOR THRESHOLD AS SPECIFIEDEXISTING EXPANSION JOINT NEW FLOORING AS SPECIFIED 1/ 2 " M A X . LO C A T I O N O F F L O O R I N G MA T E R I A L C H A N G E P E R P L A N S CONCRETE FLOORING VCT 3/32" SCHLUTER SCHIENE AE20 CENTERED UNDER DOOR. 3 CONCRETE TO VCT 6" = 1'-0" LO C A T I O N O F F L O O R I N G MA T E R I A L C H A N G E P E R P L A N S POLISHED CONCRETE FLOORING EXISTING MALL TILE 3/32" SCHLUTER SCHIENE AE20 CENTERED UNDER DOOR. 2 POLISHED CONCRETE TO MALL TILE 6" = 1'-0" GENERAL NOTES PARTITION AS SPECIFIED EXISTING WALL TILE BRUSHED STAINLESS METAL TRIM WATERPROOF MEMBRANE WHERE SPECIFIED 30 MIL. POLYETHYLENE CLEAVAGE MEMBRANE (EQUAL TO NOBEL SEAL TS) CONTINUOUS UNDER FLOORING AND UP WALL 6" MIN. BEHIND FRP AND BASE. COVED VCT BASE VCT FLOORING 6" VCT BASE 6" = 1'-0"4 1" SEE MFR SPECIFICATIONS FOR FLOORING EXPANSION TYP. PARTITION AS SPECIFIED 6" NOTCH BASE OVER EXISTING DOOR JAMBS, TYP. RUN CONTINUOUS LINE OF CAULK AT JOINT AND PAINT PT-2 FINISH. FRT. BLOCKING AS REQUIRED FOR FASTENING OF BASE TOP OF FINISH FLOOR 9 MDF BASE 6" = 1'-0" 1.IF EXISTING CONDITIONS VARY, CONTACT ARCHITECT FOR ALTERNATE TRANSITION PROFILES. 2.FLOORING TRANSITIONS TO BE PROVIDED BY G.C. AS INDICATED IN THE RESPONSIBILITY SCHEDULE ON SHEET G001. 3.PREPARE EXISTING FLOOR SURFACE PER MANUFACTURER SPECIFICATIONS FOR INSTALLATION OF NEW FLOORING MATERIALS AS INDICATED IN THESE PLANS 4.SEE MANUFACTURER SPECIFICATIONS FOR FLOORING EXPANSION LO C A T I O N O F F L O O R I N G MA T E R I A L C H A N G E P E R P L A N S 4" G.C. SHALL KEEP TRENCHING TO A MIN. TO PROVIDE STUB-UPS FOR ALL FIXTURES. 36" MAX. FOR TRENCHES 8" MAX. WIDTH, G.C. MAY ELIMINATE REBAR AND DOWELS AND SHALL APPLY BONDING AGENT TO EXISTING CONCRETE SURFACES PRIOR TO POURING (N) CONCRETE OVER COMPACTED FILL. 1-1/2" TYP. LOCATE CONDUIT ABOVE VAPOR BARRIER NEW 3,500 PSI CONCRETE SLAB ON GRADE TO MATCH DEPTH OF EXIST., WITH #3 BARS AT 16" O.C. EACH WAY AT MIDDLE DEPTH OF SLAB. DRILL AND EPOXY 6" INTO EXIST. SLAB. SAW CUT AND REMOVE EXISTING SLAB FOR TRENCH AS REQUIRED VAPOR BARRIER TO MATCH EXISTING #3 REBAR CONT. (TYP) AT ALL INTERSECTIONS AND LAPS REBAR SHALL BE TIED WITH 16 GA. REBAR TIE WIRE. TAPE IS NOT ACCEPTABLE. #3 REBAR (TYP) EPOXY COATED WITH HILTI HIT-HY 200. INSTALL PER ICC-ES-3187 EXISTING SLAB ON GRADE AS OCCURS PROVIDE CONTINUOUS SEPARATED CHEMICAL PEST BARRIER @ ALL DISTURBED AND EXPOSED SOIL PRIOR TO COVERING WITH CONCRETE AND ABC FILL COMPACTED FILL AS REQUIRED 6 SLAB DOWELING AT TRENCH 6" = 1'-0" LO C A T I O N O F F L O O R I N G MA T E R I A L C H A N G E P E R P L A N S 8 GRINDED CONC. TO POLISHED CONC. 6" = 1'-0" CENTERLINE OF DOOR OPENING DOOR AS SPECIFIED SAW CUT EXISTING SLAB WITH JOINT FILLER, COLOR TO MATCH OTHER JOINT FILLER POLISHED CONCRETE FLOORING GRINDED CONCRETE FLOORING JOINT SEALER. GC TO DETERMINE WIDTH AND DEPTH OF JOINT SEALER PER MFR RECOMMENDATIONS STOCK ROOM SALES FLOOR 5 WATERPROOF MEMBRANE TO BE INSTALL BEHIND FINISHES ONLY WHEN REQUIRED PER LOCAL JURISDICTION AND/OR LANDLORD. REFER TO FLOOR AND WALL FINISH PLAN FOR REQUIREMENTS. 6" WA T E R P R O O F ME M B R A N E WHEN REQUIRED, WATERPROOF MEMBRANE SHALL CONTINUE 6" UP WALL BEHIND FINISHES. REFER TO FLOOR AND WALL FINISH PLAN FOR FLOOR FINISH. 6" VCT COVE BASE J-MOLD END CAP TRIM CONTINUOUS ACROSS TOP EDGE AND ANY EXPOSED VERTICAL EDGES. CAULK TO PAINTED DRYWALL, NO GAPS. COLOR TO MATCH FRP. FRP PANELS TO BE SLIPPED INTO THE TRIM MOLDING CHANNEL PAINTED GYP BD. REFER TO FLOOR AND WALL FINISH PLAN FOR FLOOR FINISH. FRP SECTION 6" = 1'-0" TRIM MOLDING CHANNEL TO BE FASTENED TO THE SUB WALL. T.O.WALL PANEL +4'-10" A.F.F. +/- 0'-0" A.F.F. FINISHED FLOOR 1" SEE MFR SPECIFICATIONS FOR FLOORING EXPANSION TYP. PARTITION AS SPECIFIED 6" NOTCH BASE OVER EXISTING DOOR JAMBS, TYP. RUN CONTINUOUS LINE OF CAULK AT JOINT AND PAINT PT-1 FINISH. FRT. BLOCKING AS REQUIRED FOR FASTENING OF BASE TOP OF FINISH FLOOR 1 WOOD BASE 6" = 1'-0" B-1 TYP. B-2 TYP. TENANT SPACE MALL SPACE TENANT SPACE MALL SPACE SECTION A-A NOTES: 1.FLOOR ASSEMBLY — MIN 4-1/2 IN. (114 MM) THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR 1600-2400 KG/M³) CONCRETE. AS AN ALTERNATE, ANY MIN 2 HR FIRE RATED D700, D800 OR D900 SERIES FLOOR-CEILING DESIGN IN THE UL FIRE RESISTANCE DIRECTORY HAVING A MIN 2-1/2 IN. (64 MM) THICKNESS OF LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR 1600-2400 KG/M³) CONCRETE TOPPING OVER THE STEEL DECK MAY BE USED. MAX DIAM OF OPENING IS 12-3/4 IN. (324 MM). 2.THROUGH-PENETRANT — ONE METALLIC PIPE INSTALLED CONCENTRICALLY OR ECCENTRICALLY WITHIN OPENING. ANNULAR SPACE BETWEEN PENETRANT AND PERIPHERY OF OPENING SHALL BE MIN OF 0 IN. (POINT CONTACT) TO MAX 2 IN. (51 MM). PENETRANT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF PENETRANTS MAY BE USED: A.STEEL PIPE — NOM 10 IN. (254 MM) DIAM (OR SMALLER) SCHEDULE 40 (OR HEAVIER) STEEL PIPE. B.IRON PIPE — NOM 10 IN. (254 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. C.CONDUIT — NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR NOM 6 IN. (152 MM) DIAM (OR SMALLER) RIGID STEEL CONDUIT. 3.FIRESTOP SYSTEM — THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A.PACKING MATERIAL — MIN 2 IN. (51 MM) THICKNESS OF MIN 4 PCF (64 KG/M³) MINERAL WOOL BATT INSULATION FIRMLY PACKED INTO OPENING AS A PERMANENT FORM. WHEN CP 604, CFS-S SIL GG OR CFS-S SIL SL SEALANT IS USED (SEE ITEM 3B), MIN THICKNESS OF PACKING MATERIAL IS 4 IN. (102 MM) AND MIN THICKNESS OF FLOOR IS 4-1/2 IN. (114 MM). PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL. B.FILL, VOID OR CAVITY MATERIALS* - SEALANT — MIN 1/2 IN. (13 MM) THICKNESS OF SEALANT APPLIED WITHIN THE ANNULUS, FLUSH WITH TOP SURFACE OF FLOOR. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-ONE SEALANT, FS-ONE MAX INTUMESCENT SEALANT OR CP 604 SELF-LEVELING FIRESTOP SEALANT, CFS-S SIL GG OR CFS-S SIL SL SEALANT. W RATING APPLIES ONLY WHEN CP 604, CFS-S SIL GG OR CFS-S SIL SL SEALANT IS USED. C.DUCT WRAP MATERIAL* — ENCAPSULATED DUCT WRAP TIGHTLY WRAPPED AROUND PENETRANT TO EXTEND 24 IN. (610 MM) ABOVE THE FLOOR FOR PENETRANTS OF NOM 4 IN. (102 MM) DIAM OR SMALLER, AND 36 IN. (914 MM) ABOVE FLOOR FOR PENETRANTS GREATER THAN A NOM 4 IN. (102 MM) DIAM. AN ADDITIONAL LAYER OF ENCAPSULATED DUCT WRAP TIGHTLY WRAPPED AROUND THE FIRST LAYER OF DUCT WRAP TO EXTEND 12 IN. (305 MM) (914 MM) ABOVE FLOOR. ALL LONGITUDINAL SEAMS OF BOTH LAYERS OF DUCT WRAP AND JOINTS BETWEEN LAYERS OF DUCT WRAP ARE SEALED WITH FOIL TAPE. ONE OF THE FOLLOWING TYPES AND THICKNESSES OF DUCT WRAP MAY BE USED: C.1.NOM 1-1/2 IN. (38 MM) OR 2 IN. (51 MM) THICK ENCAPSULATED DUCT WRAP. UNIFRAX I LLC — FYREWRAP DUCT INSULATION OR FIREWRAP DUCT 1.5 INSULATION C.2.NOM 1-1/2 IN. (38 MM) THICK ENCAPSULATED DUCT WRAP. THERMAL CERAMICS INC — FIREMASTER FASTWRAP XL DUCT INSULATION *INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY. 1 3B 3A 2 3C SYSTEM NO. F-A-1105 ANSI/UL1479 (ASTM E814)ANSI/UL1479 (ASTM E814) F RATING - 2 HR F RATING - 2 HR T RATING - 2 HR FT RATING - 2 HR L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT FH RATING - 2 HR L RATING AT 400 F - 4 CFM/SQ FT FTH RATING - 2 HR W RATING - CLASS 1 (SEE ITEM 3B)L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT L RATING AT 400 F - 4 CFM/SQ FT C CL A S S IFI E D CLASSIFIED BY UNDERWRITERS LABORATORIES, INC. TO UL 1479 AND CAN/ULC-S115 US SECTION A-ANOTES: 1.FLOOR OR WALL ASSEMBLY — MIN 4-1/2 IN. (114 MM) THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR 1600-2400 KG/M³) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS*. MAX DIAM OF OPENING IS 32 IN. (813 MM). 2.METALLIC SLEEVE — (OPTIONAL) NOM 32 IN. (813 MM) DIAM (OR SMALLER) SCHEDULE 40 (OR HEAVIER) STEEL SLEEVE CAST OR GROUTED INTO FLOOR OR WALL ASSEMBLY, FLUSH WITH FLOOR OR WALL SURFACES OR EXTENDING A MAX OF 3 IN. (76 MM) ABOVE FLOOR OR BEYOND BOTH SURFACES OF WALL. 2.A.SHEET METAL SLEEVE — (OPTIONAL) MAX 6 IN. (152 MM) DIAM, MIN 26 GA. GALV STEEL PROVIDED WITH A 26 GA GALV STEEL SQUARE FLANGE SPOT WELDED TO THE SLEEVE AT APPROX MID-HEIGHT, OR FLUSH WITH BOTTOM OF SLEEVE IN FLOORS, AND SIZED TO BE A MIN OF 2 IN. (51 MM) LARGER THAN THE SLEEVE DIAM. THE SLEEVE IS TO BE CAST IN PLACE AND MAY EXTEND A MAX OF 4 IN. (102 MM) BELOW THE BOTTOM OF THE DECK AND A MAX OF 1 IN. (25 MM) ABOVE THE TOP SURFACE OF THE CONCRETE FLOOR. 2.1.SHEET METAL SLEEVE — (OPTIONAL) - MAX 12 IN. (305 MM) DIAM, MIN 24 GA GALV STEEL PROVIDED WITH A 24 GA GALV STEEL SQUARE FLANGE SPOT WELDED TO THE SLEEVE AT APPROX MID-HEIGHT, OR FLUSH WITH BOTTOM OF SLEEVE IN FLOORS, AND SIZED TO BE A MIN OF 2 IN. (51 MM) LARGER THAN THE SLEEVE DIAM. THE SLEEVE IS TO BE CAST IN PLACE AND MAY EXTEND A MAX OF 4 IN. (102 MM) BELOW THE BOTTOM OF THE DECK AND A MAX OF 1 IN. (25 MM) ABOVE THE TOP SURFACE OF THE CONCRETE FLOOR. 3.THROUGH-PENETRANT — ONE METALLIC PIPE, TUBE OR CONDUIT TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PENETRANT AND PERIPHERY OF OPENING SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 1-7/8 IN. (48 MM). PENETRANT MAY BE INSTALLED WITH CONTINUOUS POINT CONTACT. PENETRANT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PENETRANTS MAY BE USED: A.STEEL PIPE — NOM 30 IN. (762 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. B.IRON PIPE — NOM 30 IN. (762 MM) DIA (OR SMALLER) CAST OR DUCTILE IRON PIPE. C.COPPER PIPE — NOM 6 IN. (152 MM) DIA (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. D.COPPER TUBING — NOM 6 IN. (152 MM) DIA (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. E.CONDUIT — NOM 6 IN. (152 MM) DIA (OR SMALLER) STEEL CONDUIT. F.CONDUIT — NOM 4 IN. (102 MM) DIA (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING (EMT). 4.FIRESTOP SYSTEM — THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A.A. PACKING MATERIAL — MIN 4 IN. (102 MM) THICKNESS OF MIN 4 PCF (64 KG/M³) MINERAL WOOL BATT INSULATION FIRMLY PACKED INTO OPENING AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR OR SLEEVE OR FROM BOTH SURFACES OF WALL OR SLEEVE AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL. B.FILL, VOID OR CAVITY MATERIAL* — SEALANT — MIN 1/4 IN. (6 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH TOP SURFACE OF FLOOR OR SLEEVE OR WITH BOTH SURFACES OF WALL OR SLEEVE. AT THE POINT OR CONTINUOUS CONTACT LOCATIONS BETWEEN PENETRANT AND CONCRETE OR SLEEVE, A MIN 1/4 IN. (6 MM) DIAM BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE CONCRETE OR SLEEVE/ PIPE PENETRANT INTERFACE ON THE TOP SURFACE OF FLOOR AND ON BOTH SURFACES OF WALL. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-ONE SEALANT OR FS-ONE MAX INTUMESCENT SEALANT * INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY. SYSTEM NO. C-AJ-1226 ANSI/UL1479 (ASTM E814)ANSI/UL1479 (ASTM E814) F RATING - 3 HR F RATING - 3 HR T RATING - 0 HR FT RATING - 0 HR L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT FH RATING - 3 HR L RATING AT 400 F - 4 CFM/SQ FT FTH RATING - 0 HR L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT L RATING AT 400 F - 4 CFM/SQ FT C CL A S S IFI E D CLASSIFIED BY UNDERWRITERS LABORATORIES, INC. TO UL 1479 AND CAN/ULC-S115 US 1 4B 4A 3 2 3 4B A ANOTES 1.FLOOR OR WALL ASSEMBLY MIN 4-1/2 IN. THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS*. MAX AREA OF OPENING 224 SQ IN. WITH MAX DIMENSION OF 32 IN. 2.SEE CONCRETE BLOCKS (CAZT) IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS. CONDUIT ONE OR MORE NOM 4 IN DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR STEEL CONDUIT TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE SPACE BETWEEN CONDUITS OR TUBES SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 1/2 IN. THE ANNULAR SPACE BETWEEN THE CONDUIT OR TUBE AND PERIPHERY OF OPENING SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 2-3/4 IN. CONDUIT OR TUBE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. 3.CONDUIT - NOM 4 IN. DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC CONDUIT OR STEEL CONDUIT. FILL, VOID OR CAVITY MATERIAL*- FOAM MIN 5 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, EXTENDING 1/2 IN. ABOVE THE TOP SURFACE OF THE FLOOR OR BOTH SURFACES OF WALL AND OVERLAPPING THE CONCRETE 1/2 IN. ON ALL SIDES OF THE OPENING. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- CP 620 FIRE FOAM *BEARING THE UL CLASSIFICATION MARK SYSTEM NO. C-AJ-1388 ANSI/UL1479 (ASTM E814) F RATING = 2-HR T RATING = 0-HR SECTION A-A 1 2 A A 3 C CL A S S IFI E D CLASSIFIED BY UNDERWRITERS LABORATORIES, INC. TO UL 1479 AND CAN/ULC-S115 US 10 CORE SLAB DETAILS 6" = 1'-0" FLOORING AND BASE DETAILS A505 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 2 A.HARDWARE FINISHES SHALL BE BLACK FINISH UNLESS NOTED OTHERWISE. B.ALL LOCKSETS SHALL BE LEVER HANDLES C.VERIFY ALL EXISTING DOOR HARDWARE TO COMPLY WITH CURRENT CODE. SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. VERIFY EXISTING DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ARE INSTALLED BETWEEN 34" - 44" AFF. D.G.C. TO PURCHASE AND PACSUN TO INSTALL CORES PER HARDWARE SCHEDULE FROM PACSUN'S VENDOR AT TIME OF STORE TURNOVER. E.AT EXISTING DOORS TO REMAIN, VERIFY THAT EXISTING DOOR AND HARDWARE MEETS OR EXCEEDS THE REQUIREMENTS OF THESE SPECIFICATIONS. REPLACE AS REQUIRED. F.LEVER SETS TO BE FALCON GRADE 1 WITH INTERCHANGEABLE CORES. T-SERIES OR APPROVED EQUAL LEVER TO BE AVALON STYLE. G.EXIT DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE, WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. THE UNLATCHING OF ANY EXIT DOOR SHALL NOT REQUIRE MORE THAN ONE OPERATION. INSTALL ALL PANIC HARDWARE PER PLANS. GC TO INSTALL AND FURNISH. GENERAL NOTES1.SIGNAGE BY G.C.; PROVIDE SIGNAGE ABOVE DOOR(S), SEE SHEET G002. 2.POSTAL ADDRESS NUMBERS PER LANDLORD REQUIREMENTS. 3.ADA PANIC HARDWARE TO BE INSTALLED ON INSIDE WHEN REQUIRED BY LOCAL JURISDICTION. 4.LOCKS SHALL BE KEY-OPERATED WITH INDICATOR TO BE READILY DISTINGUISHABLE AS LOCKED. 5.WEATHER STRIPPING AND SWEEPS TO BE INSTALLED AS REQUIRED. 6.EXISTING DOOR - VERIFY EXISTING HARDWARE MEETS REQUIREMENTS OF, OR IS EQUAL TO SPECIFIED HARDWARE. REPLACE WITH SPECIFIED HARDWARE AS REQUIRED. 7.KICK PLATE TO BE PROVIDED ON PUSH SIDE. IF NOT, PROVIDE AND INSTALL NEW KICK PLATE ON PUSH SIDE OF DOOR: IVES 8400 10"X2" LDW630. 8.VERIFY ALL EXISTING DOOR HARDWARE TO COMPLY WITH CURRENT CODE. 9.HARDWARE PURCHASED AND INSTALLED BY G.C., DOOR PREP BY G.C.. 10.PROVIDE NON REMOVABLE PINS (NRP), PIANO TYPE HINGE OR GEARED HINGE (ROTON) AS APPROVED BY PACSUN ON IN-SWINGING DOOR. 11.ROLL DOWN SHUTTER SHALL BE OPERABLE FROM INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT WHILE THE SPACE IS OCCUPIED. 12.SHUTTER SHALL REMAIN SECURED IN THE FULL OPEN POSITION DURING THE PERIOD OF OCCUPANCY BY THE GENERAL PUBLIC. 13.MAX SHUTTER SIZE: 160 SF OR 150" HIGH. 14.PROVIDE RISER AS REQUIRED FOR CARPET INSTALLATION. 15.PROVIDE LATCH GUARD USE "BG" GUARD PLATE. 16.PROVIDE 5 1/2" THROAT. 17.VERTICALLY STIFFED HOLLOW METAL DOOR RECOMMENDED FOR SECURITY AND EASE OF INSTALLATION. 18.LOCK HARDWARE PURCHASED AND INSTALLED BY G.C. THROUGH APPROVED VENDOR, SECURITY SOURCE. 19.MOUNT AT UPPER CORNER OF DOOR AND JAMB. 20.PROVIDE APPROPRIATE RESTROOM SIGNAGE, SEE SHEET G002 & A401. 21.LOCK HARDWARE PURCHASED AND INSTALLED BY SECURITY SOURCE (VENDOR), DOOR PREP BY G.C.. 22.ORDER 6" BOTTOM BAR WITH 60° BEVEL (ALTERNATE OPTION: 10" BOTTOM BAR), 7-PIN KEYED CYLINDERS (CONSTRUCTION CORES) WITH THUMBTURNS ON INSIDE, AND PATCH HINGES WITH DOOR. 23.PROVIDE LOUVRE VENT IN DOOR U.O.N. SEE MECHANICAL SHEETS. 24.G.C. TO PAINT 4 INCH "NO STORAGE" ON DOOR. 25.PROVIDE IC-7PIN MORTISE HOUSING AND INSTAKEY CORE. 26.TAMPER-PROOF PEEP HOLE AS REQUIRED - WIDE ANGLE SET AT 60" A.F.F. UL LISTED FOR 90 MINUTE FIRE DOOR. NO PEEP HOLES ON EXTERIOR DOORS. 27.SELF-LATCHING LOCK HARDWARE PURCHASED AND INSTALLED THROUGH SECURITY SOURCE (VENDOR) BY G.C.. DOOR PREP BY G.C.. 28.SUPPLY COMPLETE EXIT DEVICE PART NUMBER BASED ON DOOR SIZE AS REQUIRED. 36" DOOR = 36, NARROW STILE = NS, DOUBLE DOOR = 94. FOR NARROW STILE, ADD NARROW STILE KIT #101879-1. 29.BOTTOM RAIL TO BE 10" MINIMUM. 30.PROVIDE ADDITIONAL INTERMEDIATE PIVOT FOR DOORS 8'-0" AND TALLER. 31.DO NOT PROVIDE HOLD OPEN DEVICE ON DOOR IF TACTILE SIGNAGE IS MOUNTED TO DOOR. 32.PAINT DOOR AND FRAME P101 ON SALES AREA SIDE ONLY. 33.THERE SHALL BE A LEVEL AND CLEAR FLOOR OR LANDING ON EACH SIDE OF A DOOR. THE LEVEL AREA SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60" AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF 48" AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN THE CLOSED POSITION. THE FLOOR OR LANDING SHALL BE LESS THAN OR EQUAL TO 1/2" LOWER THAN THE THRESHOLD. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THEN 1/4" AT DOORWAYS SHALL BE BEVELED WITH SLOPE NOT GREATER THEN 1 UNIT VERTICAL IN 2 UNITS HORIZONTAL 34.MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS. SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. DOOR NOTES LEGEND 1'- 0 " KICK PLATE 8'- 0 " T Y P . 7'- 0 " TY P . TACTILE STORE ADDRESS SIGN MUST DISPLAY OFFICIAL ADDRESS ON EXTERIOR SURFACE OF DOOR. THE FOLLOWING ADDRESS: 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14, ARCADIA, CALIFORNIA 91007 ON SERVICE DOOR. "ADDRESS" SIGN ON EXTERIOR FACE OF DOOR. OPENING IN WALL 1'- 1 0 " 5'- 2 " PT-4 1.SIGNAGE IDENTIFICATION: 1.1.TENANT G.C. MUST INSTALL SIGNAGE CENTERED JUSTIFIED ON EXTERIOR FACE OF SERVICE DOOR IN CONTRASTING COLOR OF FINISH OF DOOR. ADDRESS FONT MUST BE 0'-2 1/2" IN ARIAL BOLD FONT DISPLAYING BOTH TENANT'S NAME AND SUITE NUMBER. 1.2.KNOX BOX ZONE IDENTIFICATION PLACARD. 1.3.ROOFTOP HVAC EQUIPMENT IDENTIFICATION PLACARD ON ALL ROOF TOP EQUIPMENT AND PENETRATIONS HVAC UNITS, VENTS MECHANICAL OR PLUMBING, DISHES, ETC. THAT ARE EXCLUSIVELY SERVICING THE TENANT SPACE. 1.4.MALL ELECTRICAL ROOM METER AND SERVICE DISCONNECT IDENTIFICATION PLACARDS. 1.5.SPACE WATER MAIN SHUT OFF VALVE SIGN IN CORRIDOR. 1.6.IDENTIFICATION LABELS FOR ALL EQUIPMENT, CONDUIT LINE SET, ETC. OUTSIDE OF THE SPACE. 2.TENANT G.C. TO ENSURE THE SECURITY OF TENANT'S PREMISES BY WHATEVER MEASURES DEEMS NECESSARY, INCLUDING RE-KEYING OF ALL LOCKSETS. LANDLORD REQUIREMENT NOTE TYP. DOOR SCHEDULE DOOR #DESCRIPTION DOOR FRAME DETAILS FIRE RATING HARDWARE FURNISHED BY INSTALLED BY NOTES SIZE TYPE MATERIAL FINISH MATERIAL FINISH SILL JAMB HEAD FINISH 1 SECURITY GRILLE - ENTRY 16'-0" X 10'-0" V.I.F.A METAL CLEAR ANODIZED METAL CLEAR ANODIZED 2/A505 4/A303 7/A303 CLEAR ANODIZED --G.C.G.C.G.C. TO INSTALL SECURITY EQUIPMENT AS INSTRUCTED BY MANUFACTURE. REFER TO GRILLE IN STOREFRONT FINISH SCHEDULE. FINISH TO MATCH STOREFRONT SYSTEM. 2 (E) SERVICE CORRIDOR DOOR 3'-0" X 7'-0" X 1 34" V.I.F.B EXISTING PT-4 EXISTING PT-4 7/A505 EXISTING EXISTING INTERIOR: PT-4 EXTERIOR: PT-8 (E) 1 HR EXISTING G.C.-G.C. TO CLEAN DOOR AND FRAME, PAINT DOOR & INSTALL HARDWARE WIHT PANIC PUSH BAR 3 (E) TOILET ROOM 3'-0" X 7'-0" X 1 3 4" V.I.F.C EXISTING PT-4 EXISTING PT-4 3A505 EXISTING EXISTING PT-4 -EXISTING G.C.- 4 HALLWAY 3'-0" X 7'-0" X 1 34"E -PT-4 -PT-4 ------G.C.G.C.G.C. TO FRAME OUT OPENING WHERE INDICATED IN THESE PLANS. 5 ADA FITTING ROOM 3'-0" X 6'-0" X 1 3 4"G SOLID MAPLE WOOD -WOOD PT-4 -4/A611 -CLEAR COAT -HW2 G.C.G.C. 6 FITTING ROOM 3'-0" X 5'-0" X 1 3 4"F SOLID MAPLE WOOD -WOOD PT-4 -4/A611 -CLEAR COAT -HW2 G.C.G.C. 7 HALLWAY TO RESTROOMS AND EXIT DOOR 3'-0" X 7'-0" X 1 3 4"K WOOD PT-4 WOOD PT-4 8/A505 3/A611 2/A611 PT-4 -HW3 G.C.G.C.W/ PANIC PUSH BAR 8 STOCK ROOM 3'-0" X 7'-0" X 1 34"D WOOD PT-4 WOOD PT-4 8/A505 3/A611 2/A611 PT-4 -HW3 G.C.G.C. 9 (E) SERVICE CORRIDOR DOOR 3'-0" X 7'-0" X 1 3 4" V.I.F.H EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING INTERIOR: PT-4 EXTERIOR: PT-8 (E) 1 HR EXISTING G.C.-G.C. TO CLEAN EXTERIOR DOOR AND FRAME, CLOSE AND LOCK THE DOOR IN THE CLOSED POSITION AND PREPARE TO BE WELD SHUT. 10 (N) CORRIDOR EXIT DOOR 3'-0" X 7'-0" X 1 34" V.I.F.J METAL METAL METAL METAL 5/A611 5/A611 5/A611 INTERIOR: PT-4 EXTERIOR: PT-8 (N) 1 HR MATCH EXISTNG G.C.G.C.NEW 1HR DOOR WITH PANIC HARDWARE INSTALLED PER CODE 1 DOOR TYPES DOOR HARDWARE LEGEND HW1 HW2 HW3 HW4 HW5 SALES/NON-SALES DOOR: 3'-0" X 7'-0" HOLLOW METAL DOOR AND FRAME WITH CONTINUOUS SS BARREL HINGE (STANLEY 651 7'-0" OR EQUAL). HINGE AND S/S LEVER TYPE PASSAGE SET WITH SELF CLOSING DEVICE. (90 MIN. RATING FOR DOORS OPENING TO ONE HOUR PASSAGEWAY, 20 MIN. RATING AT DOORS OPENING TO UNPROTECTED PASSAGEWAY). NO LOCKS PERMITTED ON SALES AREA DOOR. TENANT G.C. TO INSTALL DOOR, FRAME, LATCHSET AND 34" X 34" X 1/8" STAINLESS STEEL ARMOR KICK PLATE FASTEN TO DOOR WITH SELF THREADING PAN HEAD SCREWS. PAINT PER ELEVATIONS. CAULK BOTTOM OF DOOR FRAME. DOOR STOP - DS-3. SEE SPECIFICATIONS SHEET. ALL FITTING ROOM DOORS: DOORS, JAMBS, BUTTS, HANDLE AND LOCKING HARDWARE SUPPLIED BY TENANT G.C. AND INSTALLED BY TENANT G.C. TENANT G.C. TO INSTALL DOOR, FRAME, AND LATCHSET. TENANT G.C. SHALL PROVIDE AND INSTALL CLEAR PLASTIC DOOR BUMPERS. DOOR BUMPERS ON JAMBS SHALL BE 6'-0" LONG AND INSTALLED AT LENGTH OF DOOR ONLY (DO NOT EXTEND STOPS TO FLOOR AND HEAD). PAINT PER ELEVATIONS. TENANT G.C. TO MORTISE DOOR ONLY. JAMB HINGES TO BE MORTISE. CAULK BOTTOM OF DOOR FRAME. LATCHSET SHALL BE LEVER TYPE AND SHALL COMPLY WITH ADA, ANSI, TAS AND CALDAG REQUIREMENTS. LEVER SETS - LVS-1. SEE SPECIFICATIONS SHEET. HINGES: SCHLAGE (2) 3.5" X 3.5" PLAIN BEARING 5/8" RADIUS CORNER MORTISE HINGES - MATTE BLACK FINISH. ADA TO HAVE (3) HINGES. DOOR STOP - DS-1 FITTING ROOM. SEE SPECIFICATIONS SHEET. DS-2 ADA FITTING ROOM. SEE SPECIFICATIONS SHEET. TENANT G.C. TO INSTALL 'DELTANA DOME STOP' HIGH PROFILE BUMPER #DSHP916U26D, FINISH US26D (BRUSHED CHROME). TENANT G.C. TO SUPPLY AND INSTALL DOOR SILENCERS. ALL FITTING ROOM DOORS TO BE KEYED THE SAME SC-1. STORAGE/STOCK ROOM/HALLWAY DOOR: DOORS, JAMBS, BUTTS, HANDLE AND LOCKING HARDWARE SUPPLIED BY TENANT G.C. AND INSTALLED BY TENANT G.C. DOOR CLOSER, LAWRENCE HARDWARE LH816, POLISHED CHROME - US26 (625). TENANT G.C. TO INSTALL DOOR, FRAME, AND LATCHSET. TENANT G.C. SHALL PROVIDE AND INSTALL CLEAR PLASTIC DOOR BUMPERS. DOOR BUMPERS ON JAMBS SHALL BE 6'-0" LONG AND INSTALLED AT LENGTH OF DOOR ONLY (DO NOT EXTEND STOPS TO FLOOR AND HEAD). PAINT PER ELEVATIONS. TENANT G.C. TO MORTISE DOOR ONLY. JAMB HINGES TO BE SURFACE MOUNTED. CAULK BOTTOM OF DOOR FRAME. LEVER SETS - LVS-2. SEE SPECIFICATIONS SHEET. DOOR STOP TO BE DELTANA DOME STOP HIGH PROFILE BUMPER. PRODUCT #DSH916US26D, FINISH US26D (BRUSHED CHROME). TENANT G.C. TO SUPPLY AND INSTALL DOOR SILENCERS. ALL STORAGE AND STOCK ROOM DOORS TO BE KEYED THE SAME SC-1. DOOR STOP - DS-3. SEE SPECIFICATIONS SHEET. DOORS IN DIRECTION OF LIFE SAFTEY EGRESS TO BE INSTALLED WITH A PANIC PUSH BAR PER CODE. ENTRY DOOR: EXISTING DOOR TO REMAIN. NEW ENTRY DOOR PULL - PULL-1 SEE SPECIFICATIONS NOT USED. OPEN TO MALL A B PACSUN 400 SOUTH BALDWIN AVE., ARCADIA, CALIFORNIA 91007 H-12. H-13AND H-14 C (E ) 7 ' - 0 " V. I . F . D 7'- 0 " T Y P . 2 - E 2 - TYP. "EMPLOYEE ONLY" SIGN KICK PLATE PT-4 KICK PLATE PT-4 7'- 0 " T Y P . BASE BOARD CONTINUED AROUND CORNER, TYP.F G 8'- 0 " T Y P . 1'- 1 0 " 6'- 0 " MAPLE DOOR MAPLE JAMB TYP. TYP. MAPLE DOOR MAPLE JAMB TYP. TYP. (E ) 7 ' - 0 " V. I . F . 16'-0" MAX. H DOOR TO BE WELDED IN SHUT AND LOCKED POSITION WHERE INDICATED IN THESE PLANS. 10 ' - 0 " M I N . SECURITY GRILLE PER PLAN B-1 PT-1 TYP. TYP. B-1 PT-1 TYP. TYP. 3 - 3 - 3 - 3 - 4 - 4 - TYP.TYP.TYP.TYP.TYP.TYP. TYP. 2 - TYP. 2 - J 7'- 0 " T Y P . 5 - TYP. KICK PLATE PT-4 5 - SIM. K 7'- 0 " T Y P . 2 - TYP. KICK PLATE PT-4 3 - SIM. TYPICAL JAMB DETAIL 3" = 1'-0" 1/ 2 " 1/ 2 " 2" PARTITION AS SPECIFIED NOTCH WOOD WALL BASE AROUND DOOR JAMB IN SALES AREA. CONTINUOUS BEAD OF CAULK AND PAINT FINISH, TYP. CONTINUOUS SEALANT TYP. HOLLOW METAL KNOCKDOWN FRAME. PAINT PER DOOR SCHEDULE. DOUBLE STUDS AT JAMBS AS SCHEDULED TYP. DOOR AS SCHEDULED STEEL STUD JAMB ANCHOR (3 PER JAMB, MIN.) 3TYPICAL HEAD DETAIL 3" = 1'-0" 1/2"1/2" DOOR AS SCHEDULED CONTINUOUS SEALANT TYP. PARTITION AS SPECIFIED HOLLOW METAL KNOCKDOWN FRAME 2" M I N . TO F I N I S H C E I L I N G 2" 2 55 NEW 1HR WALL AND 90 MIN DOOR - UL #U465 3" = 1'-0" DOOR STOP (5'-0" AND 6'-0" LONG, ALIGN WITH TOP OF DOOR). TYPICAL FITTING ROOM JAMB DETAILS 3" = 1'-0" 5/8" TYPE "X" GYP. BD. BOTH SIDES OVER 3-5/8" METAL STUDS. JAMB (REFER TO DOOR SCHEDULE FOR HEIGHT, DETAILS, AND ELEVATION). DOOR AS SCHEDULEDDOOR AS SCHEDULED 5/8" TYPE "X" GYP. BD. BOTH SIDES OVER 3-5/8" METAL STUDS. 3/4" 5" 2" 3/ 4 " 2 1 / 4 " 1" 2 1 / 4 " 3/ 4 " 5" 2" 1" JAMB (REFER TO DOOR SCHEDULE FOR HEIGHT, DETAILS, AND ELEVATION) LEFT JAMB DETAIL RIGHT JAMB DETAIL FITTING ROOM DOOR IS TO BE HINGED ON FITTING ROOM SIDE OF JAMB. REFER TO PLANS FOR DIRECTION OF DOOR SWING, TYP. WOODEN DOWEL CONNECTION SCREWS ARE TO BE RECESSED INTO JAMB. FILL SCREW HOLE WITH WOOD FILLER, SAND SMOOTH, PRIME AND PAINT TO MATCH WOOD FINISH. TYP. TOP OF JAMB AND TOP OF DOOR ARE TO BE ALIGNED WITH EACH OTHER, TYP. FITTING ROOM HALLWAY BA 3'-2" OPENING 3'-0" DOOR 3'-0" 1/4" 4 REAR SERVICE CORRIDOR HALLWAY EXISTING CONCRETE SLAB 90 MINUTE 'B' LABEL METAL DOOR AND WELDED METAL FRAME (PROVIDED AND INSTALLED BY TEN G.C. (2) LAYERS CONTINUOUS 5/8" TYPE 'X' GYP. BD. ON 3-5/8" X 20ga METAL FRAMING - PER UL DESIGN 465 - (2) TWO LAYERS OF 5/8" GYP BD SHALL ACHIEVE A (1) HOUR FIRE RATING 5/8" TYPE 'X' GYPSUM BOARD TIGHT TO DECK ABOVE TO MAINTAIN A 1-HOUR RATING PER U.L. DESIGN U465. TOP CONNECTION 10/A504 NEW ADA TRANSITION AND SMOKE FIRE SEAL MATCH EXISTING ADJACENT WALL TYPE AND FINISH. COORDINATE WITH LANDLORD DOOR SCHEDULE A6112 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 2 2 2 2 2 2 2 2 FLOORING FINISH SCHEDULE TAG DESCRIPTION MANUFACTURER PRODUCT PRODUCT NUMBER STYLE COLOR SIZE FLAME SPREAD / SMOKE DEVT.FURNISHED BY INSTALLED BY NOTES ST-1 CONCRETE FLOORING - SALES AREA TBD BY OWNER -POLISHED ---G.C.G.C.GRIT UP TO 400. REFER TO FINISH PLAN FOR LOCATION. ST-2 CONCRETE FLOORING - STOCK ROOM TBD BY OWNER -GRIND AND SEALED ---G.C.G.C.GRIT UP TO 400. REFER TO FINISH PLAN FOR LOCATION. VCT-1 SHEET VINYL FLOORING - RESTROOM(S)TBD BY G.C.-POLISHED ---G.C.G.C.INSTALL PER MANUFACTURE INSTRUCTIONS. REFER TO FINISH PLAN FOR LOCATION. CEILING FINISH SCHEDULE TAG DESCRIPTION MANUFACTURER PRODUCT STYLE COLOR SIZE FLAME SPREAD / SMOKE DEVT.FURNISHED BY INSTALLED BY NOTES C-1 LAY-IN ACOUSTICAL CEILING SYSTEM - WHERE APPLICABLE ARMSTRONG FINE FISSURED SECOND LOOK 1761C FINE FISSURED SECOND LOOK WHITE 24" X 48" TEGULAR EDGE CLASS A G.C.G.C.ARMSTRONG PRELUDE XL 15/16" TEE GRID. SEE REFLECTED CEILING PLANS FOR LOCATION. C-2 LAY-IN ACOUSTICAL CEILING SYSTEM - SALES AREA ARMSTRONG MESA 681 -WHITE 24" X 24" ANGLED TEGULAR EDGE, 3/4" THICK CLASS A G.C.G.C.ARMSTRONG PRELUDE XL 15/16" TEE GRID. SEE REFLECTED CEILING PLANS FOR LOCATION. E EXISTING EXISTING EXISTING EXISTING TBD BY OWNER EXISTING ---VERIFY EXISTING CONDITION. PATCH AND REPAIR AS NEEDED. GYP HARDLID CEILNG TBD BY G.C.--PAINT TO MATCH SPACE --G.C.G.C.SEE REFLECTED CEILING PLANS FOR LOCATION. OPEN OPEN TO BOTTOM OF DECK - WHERE APPLICABLE OPEN PAINT TO MATCH N/A -G.C.G.C.SEE REFLECTED CEILING PLANS FOR LOCATION. PAINT, WALLCOVERING, AND WINDOW FINISH SCHEDULE TAG DESCRIPTION MANUFACTURER PRODUCT PRODUCT NUMBER COLOR FINISH SIZE FLAME SPREAD / SMOKE DEVT.FURNISHED BY INSTALLED BY NOTES FILM-1 WINDOW VINYL FILM - NOT USED.BELBIEN VINYL FILM -----G.C.G.C. FILM-2 WINDOW VINYL FILM - NOT USED.BELBIEN VINYL FILM -----G.C.G.C. FRP-1 FRP MARLITE STANDARD FRP P100 WHITE PEBBLE SURFACE 4'-0"X 10'-0" X 3/32"-G.C.G.C.ALL TRIM PIECES AND CORNER GUARDS AS REQUIRED, FINISH TO MATCH. REFER TO PLANS AND ELEVATIONS FOR LOCATION. PT-1 PAINT - SALES AREA SHERWIN WILLIAMS ACRYLIC LAYTEX SW 7004 SW7004: SNOWBOUND EGGSHELL --G.C.G.C.REFER TO INTERIOR ELEVATIONS. PT-2 PAINT - SALES AREA'S BASE AND TRIM SHERWIN WILLIAMS ACRYLIC LAYTEX SW 7004 SW7004: SNOWBOUND SEMI-GLOSS --G.C.G.C.REFER TO INTERIOR ELEVATIONS. PT-3 PAINT - FITTING AREAS AND HALLWAY BENJAMIN MOORE SCUFF X -MATCH SW SNOWBOUND EGGSHELL --G.C.G.C.REFER TO INTERIOR ELEVATIONS. PT-4 PAINT - FITTING AREAS AND HALLWAY'S BASE, TRIM AND DOORS BENJAMIN MOORE SCUFF X -MATCH SW SNOWBOUND SEMI-GLOSS --G.C.G.C.REFER TO INTERIOR ELEVATIONS. PT-5 PAINT - CASHWRAP / BACKWRAP BENJAMIN MOORE SCUFF X 2132-10 BLACK SEMI-GLOSS --G.C.G.C.REFER TO INTERIOR ELEVATIONS. PT-6 PAINT - NEUTRAL PIERS DUNN EDWARDS SPARTAZERO SZR020-0 CRISP WHITE SHIRT INTERIOR VELVET --G.C.G.C.REFER TO MALL SPECIFICATIONS AND MANAGEMENT PRIOR TO FINISHING. PT-7 PAINT - BULK HEAD AND CEILING DUNN EDWARDS SPARTAZERO SXRO10-0 CRISP WHITE SHIRT INTERIOR FLAT --G.C.G.C.REFER TO MANAGEMENT FOR ADDITIONAL QUESTIONS. PT-8 PAINT - SERVICE DOOR AND FRAME DUNN EDWARDS ASTROSHIELD ASHL50-0 DEEP ONYX INTERIOR / EXTERIOR SEMI-GLOSS --G.C.G.C.PAINT TO BE ON EXTERIOR MALL SIDE OF DOOR. REFER TO DOOR SCHEDULE AND MANAGEMENT FOR ADDITIONAL QUESTIONS. CG-1 CORNER GUARD - NON-SALES AREAS TBD BY G.C.--SS ROUNDED CORNERS 48" X 1-1/2" X 1-1/2"NSF CERTIFIED G.C.G.C.INSTALLATION: MANUFACTURER RECOMMENDED ADHESIVE. MOUNTED ABOVE WALL BASE. 90° 1-1/2" ROUNDED 16ga. CORNER GUARD, 48" LENGTH. CG-2 CORNER GUARD - SALES AREA TBD BY G.C.--CLEAR ROUNDED CORNERS 48" X 1-1/2" X 1-1/2",NSF CERTIFIED G.C.G.C.INSTALLATION: MANUFACTURER RECOMMENDED ADHESIVE. MOUNTED ABOVE WALL BASE. 90° 1-1/2" ROUNDED 16ga. CORNER GUARD, 48" LENGTH. SF-1 POLISHED PLASTER - STOREFRONT ARMOURCOAT POLISH PLASTER P70 / P80 SPATULATA NATURAL WHITE -CLASS 1 G.C.G.C.REFER TO STOREFRONT ELEVATIONS. INSTALL FINISH PER MANUFACTURER'S SPECIFICATION AND RECOMMENDATIONS. LIGHTING SCHEDULE REPRESENTATIVE CONTACT:JULIE GLESNE 206-455-5666 REACH OUT WITH ANY QUESTIONS. TAG DESCRIPTION MANUFACTURER PRODUCT PRODUCT NUMBER STYLE COLOR SIZE DIM.FURNISHED BY INSTALLED BY NOTES L-1P RECESSED FIXTURE - SALES AREA CORONET SUSPENDED LINEAR DIRECT LIGHT LS1-LP-XX-30-HIGH-UNV-D B-W-AC-FL-NA-NA-NA 3000K, 800LM, 10W, 90 CRI WHITE 2.9"-3.5" H x 1.9"-3"W x 8'L 0-10 DIM PACSUN G.C.REMOTE DRIVERS (VERIFY AC CABLE LENGTH REQUIRED WITH SITE CONDITIONS.) L-2T TRACK FIXTURE - SALES AREA CONTECH LIGHTING SURFACE MOUNT TRACK LT-8-P 120V WHITE 1-3/8"W x 11/16"H x 8' L -PACSUN G.C. +L-2T TRACK FIXTURE - SALES AREA CONTECH LIGHTING -LT-2-P 120V MINI CONNECTOR WHITE --PACSUN +L-2T TRACK FIXTURE - SALES AREA CONTECH LIGHTING -LA-12-P 90° CONNECTOR WHITE --PACSUN +L-2T TRACK FIXTURE - SALES AREA CONTECH LIGHTING -LA-23T-R-P / REG6-P 5A CURRENT LIMITER PO --PACSUN L-2TWW TRACK FIXTURE -LUMENTURE TRACK MOUNT WALL WASH FIXTURE TWW-160-30H-1600-W-J 3000K, 1600LM, 17W, 90CRI, J TYPE ADAPTER WHITE -INC PACSUN L-2TS TRACK ACCENT FIXTURE -LUMENTURE TRACK MOUNT ACCENT LIGHT T50-30H-1100-15-W-J-SN 3000K, 1100LM, 14W, 90 CRI, J TYPE ADAPTOR WHITE -INC PACSUN G.C.15 DEGREE SPOT WITH SNOOT L-4 PENDENT FIXTURE - FITTING ROOM HALWAY SONNEMAN KOMA TAISHO 2750.03-E 1 BULB, 75W, MEDIUM SATIN WHITE ALUMINUM 11"H x 9"D INC PACSUN G.C.MOUNT 7'-6" A.F.F. TO BOTTOM OF FIXTURE (VERIFY AC CABLE LENGTH REQUIRED WITH SITE CONDITIONS.). +L-4 FIXTURE LED LAMP SATCO -S8499 3000K, 1050LM, 12.5W, 90 CRI, A19, 120V LED LAMP -INC PACSUN L-5S RECESSED LIGHT - FITTING ROOM SEASCAPE LUCA LED FLUSH MOUNT LUCA FLUSH - WHITE LINEN - 15X5 - 2 MEDIUM BASE SOCKETS - 20W MAX WATTAGE LABEL 2000LM, 20W MAX LABEL, 90 CRI WHITE LINEN SHADE 15"D x 3"H TWO MEDIUM BASE SOCKETS INC PACSUN G.C. +L-5 FIXTURE LAMP SATCO DIMMABLE LAMP S9704 3000K, 800LM, 10W, 90 CRI, A19, 120V --INC PACSUN L-8 RECESSED LIGHT - STOCK ROOM & NON-SALES AREA VALRIYA 2'X4' TROFFER VA-TTR-24-40-3000K 3000K, 5000LM, 40W, 80 CRI WHITE 2' x 4'0-10V PACSUN G.C. EM EMERGENCY LIGHT FIXTURE DUAL LITE EM LIGHT LZ2-03L 10W, 6V,WHITE 3W LED LAMPS N/A PACSUN G.C.CONTAINS LEAD CALCIUM BATTERY. EX EXIT SIGN FIXTURE WITH GREEN LETTERS EXITRONIX SINGLE FACED EXIT SIGN S902-WB-SR-WB-GC-AG 10 TO 277 VAC EDGE-LIT EXIT SIGN WITH GREEN LETTERS, SINGLE FACE FIELD INSTALLED ARROWS SILVER TRIM N/A PACSUN G.C.CONTAINS INTEGRAL BATTERY. UNIVERSAL MOUNTING. (E)EXISTING LIGHT FIXTURE EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING ---EXISTING LIGHT FIXTURE TO REMAIN AS IS. NOTES: *REFER TO MANUFACTURE FOR INSTALL. *REFER TO PLANS FOR LOCATION AND MOUNTING *DIMMING CONTROLS SPECIFIER IS RESPONSIBLE FOR ALL DIMMING LOADS (ELV, MLV, 0 TO 10 ETC.) AND VERIFICATION OF LUMINAIRES DIMMING RANGE (1%,10% ETC.) *LIGHTING CONTROLS CONSIST OF WALL BOX DIMMERS AND OCC SENSORS, PROVIDED BY OTHERS. SCHEDULES A700 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 2 TRIM FINISH SCHEDULE TAG DESCRIPTION MANUFACTURER PRODUCT PRODUCT NUMBER COLOR SIZE FLAME SPREAD / SMOKE DEVT.FURNISHED BY INSTALLED BY NOTES B-1 BASE AND TRIM - SALES AREA TBD BY G.C.MDF PAINTED PT-2 4" H -G.C.G.C.REFER TO ELEVATIONS FOR LOCATION AND DETAIL 9/A561. B-2 WOOD BASE AND TRIM - FITTING AREA AND HALLWAY TBD BY G.C.MAPLE WOOD MATTE 4" H -G.C.G.C.REFER TO ELEVATIONS FOR LOCATION AND DETAIL 1/S561. B-3 RUBBER COVE BASE - TOILET ROOM ROPPE 700 SERIES WALL BASE WHITE 6" H -G.C.G.C.REFER TO ELEVATIONS FOR LOCATION AND DETAIL 4/A561. B-4 RUBBER COVE BASE - STOCK ROOM ROPPE 700 SERIES WALL BASE BLACK BROWN 6" H -G.C.G.C.REFER TO ELEVATIONS FOR LOCATION AND DETAIL 4/A561. WD-1 WOOD BASE - CASHWRAP TBD BY G.C.-PAINTED TO MATCH -G.C.G.C.REFER TO ELEVATIONS FOR LOCATION AND DETAIL 1/A561. STOREFRONT FINISH SCHEDULE TAG DESCRIPTION MANUFACTURER PRODUCT STYLE COLOR SIZE FLAME SPREAD / SMOKE DEVT.FURNISHED BY INSTALLED BY NOTES MTL-1 METAL STOREFRONT SYSTEM TBD BY G.C.--CLEAR ANODIZED 11 OR SIMILAR -G.C.G.C.INSTALL AS SHOWN IN THESE PLANS. REFER TO STOREFRONT ELEVATIONS, SECTIONS AND DETAILS. MTL-2 METAL STOREFRONT SYSTEM - NOT USED ------G.C.G.C. THERMAL - STOREFRONT SYSTEM KAWNEER TRIFAB VERSAGLAZE 451T #14 CLEAR 2" X 4 1/2"-G.C.G.C. NON-THERMAL - STOREFRONT SYSTEM KAWNEER TRIFAB VERSAGLAZE 451 #14 CLEAR 2" X 4 1/2"-G.C.G.C. HURRICANE RESISTANT - STOREFRONT SYSTEM KAWNEER 1R 501 CENTERGLAZED #14 CLEAR 2 1/2" X 5"-G.C.G.C. GRILLE SECURITY GRILLE - STOREFRONT QMI USA SOLID & ALUMINUM SHUTTERS STYLE 51 PUNCH PATTERN,CLEAR ANODIZED 16'-0" X 10'-0"-G.C.G.C.TOP MOTORIZED STORE SAFE AL7, KEY SWITCH TO ACCEPT BEST 7 PIN CORE. INSTALL PER MANUFACTURE WHERE INDICATED IN THESE PLANS. FINISH TO MATCH STOREFRONT SYSTEM. REFER TO DOOR SCHEDULE AND DETAILS FOR MORE INFORMATION. FIXTURE SCHEDULE TAG DESCRIPTION MANUFACTURE PRODUCT PRODUCT NUMBER MATERIAL FINISH SIZE FLAME SPREAD / SMOKE DEVT.QUANTITY CONDITION FURNISHED BY INSTALLED BY NOTES AB ACCESSORY BAR TBD BY OWNER ------NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. AC ACCESSORY CONSOLE TBD BY OWNER ------NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. BM-B BRANDY MELVILLE BENCH TBD BY OWNER ------NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. BM-T BRANDY MELVILLE TABLE TBD BY OWNER ------NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. BW BLACK WARDROBER TBD BY OWNER ------NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. CLOSER-1 DOOR CLOSER - SERVICE DOOR LAWRENCE LH816-US26 -POLISHED CHROME (625)NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. CT CONSOLE TAABLE TBD BY OWNER ------NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. DS-1 DOOR STOP - FITTING ROOMS BALDWIN WALL MOUNT CONVEX FLUSH BUMPER 4015190 BRASS / RUBBER SATIN BLACK 1"DIAMETER x 1"D NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. DS-2 DOOR STOP - ADA FITTING ROOM DELTANA DOME DOOR STOP DSHP916U19 SOLID BRASS PAIN BLACK 2"L x 1-3/4"W x 1-3/8"H NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. DS-3 DOOR STOP - NON-SALES AREA DELTANA DOME DOOR STOP DSHP9116U26 SOLID BRASS POLISH CHROM (US26)2"L x 1-3/4"W x 1-3/8"H NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. DT DENIM TABLE TBD BY OWNER ------NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. GP GRID PLATFORM TBD BY OWNER REFER TO PLAN AND ELEVATIONS FOR LOCATION. HOOK-1 COAT HOOKS - FITTING ROOMS MOEN TRIVIA SINGLE ROBE HOOK BP1803BL -MATTE BLACK 2"W x 2-5/16"H x 2-1/4"D NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. LN LARGE NESTER TBD BY OWNER -----REFER TO PLAN AND ELEVATIONS FOR LOCATION. LVS-1 LEVER SET - FITTING ROOMS YALE LOCKS PRIVACY LEVER SET YALE 4602LN -BLACK SUEDE POWDER COAT BACKSET: 2-3/4" LATCH: 1-1/8" X 2-1/4" FACE, 1/2" THROW UL-cUL FIRE RATED UP TO 3-HOURS NEW PACSUN G.C.3 YEAR WARRANTY PER MGF. REFER TO HW2 ON SHEET A611 FOR MORE INFORMATION. LVS-2 LEVER SET - NON-SALES ARROW LOCK STORE ROOM LEVER SET RL-12-SR-IC-26D-R62-R71 -US26D SATIN CHROME NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. MC METAL CUBE TBD BY OWNER -----REFER TO PLAN AND ELEVATIONS FOR LOCATION. REFER TO DETAILS FOR MOUNTING TYPE. MR MANNEQUIN RISER TBD BY OWNER -----REFER TO PLAN AND ELEVATIONS FOR LOCATION. REFER TO DETAILS FOR MOUNTING TYPE. MM MEN'S FULL FORM MANNEQUIN TBD BY OWNER -----REFER TO PLAN AND ELEVATIONS FOR LOCATION. REFER TO DETAILS FOR MOUNTING TYPE. MI BODY MIRROR TBD BY OWNER --MIRROR BLACK 3'-0"W x 6'-0"L MOUNTED 20" MAX. A.F.F.G.C.G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. REFER TO DETAILS FOR MOUNTING TYPE. PULL-1 DOOR PULL - MAIN ENTRY ROCKWOOD OFFSET SINGLE BAR SET BF15747CT3 315 ALUMINUM BLACK ANODIZED PUSH 2-3/4", PULL 3-1/2", 1" D THICKNESS 33" CTC X 10" CTC NEW PACSUN G.C.1-3/4" CLEARANCE. REFER TO PLANS AND ELEVATIONS FOR LOCATION. RI RISER NESTER TBD BY OWNER -----REFER TO PLAN AND ELEVATIONS FOR LOCATION. RTN ROUND TABLE WITH NESTERS TBD BY OWNER -----REFER TO PLAN AND ELEVATIONS FOR LOCATION. SC STONE CUBE TBD BY OWNER -----REFER TO PLAN AND ELEVATIONS FOR LOCATION. SMF SMALL MINI FEATURE WALL TBD BY OWNER -----REFER TO PLAN AND ELEVATIONS FOR LOCATION. TEE TEE TABLE TBD BY OWNER -----REFER TO PLAN AND ELEVATIONS FOR LOCATION. TS T-STAND TBD BY OWNER -----REFER TO PLAN AND ELEVATIONS FOR LOCATION. TWW TALL WHITE WARDROBE TBD BY OWNER -----REFER TO PLAN AND ELEVATIONS FOR LOCATION. F-1 MIRROR - FITTING ROOMS TBD BY G.C.--BLACK 1" FRAME 6'-0" H x 3'-0" W -NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. REFER TO DETAILS FOR MOUNTING TYPE. F-2 MIRROR - FITTING ROOM HALLWAY MIRROR TBD BY G.C.--BLACK 1" FRAME 7'-0" H x 3'-0" W -NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. REFER TO DETAILS FOR MOUNTING TYPE. F-3 MIRROR - SALES TBD BY G.C.--BLACK 1" FRAME 7'-0" H x 2'-0" W -NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. REFER TO DETAILS FOR MOUNTING TYPE. F-4 MIRROR - SALES TBD BY G.C.--BLACK 1" FRAME 7'-0" H x 1'-0" W -NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. REFER TO DETAILS FOR MOUNTING TYPE. F-5 MIRROR - SALES TBD BY G.C.--BLACK 1" FRAME 7'-0" H x 1'-6" W -NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. REFER TO DETAILS FOR MOUNTING TYPE. FRB FITTING ROOM BENCH - ADA TBD BY OWNER 17-19"H x 24"W x 48"L NEW REFER TO PLAN AND ELEVATIONS FOR LOCATION. FRS FITTING ROOM STOOL TBD BY OWNER NEW REFER TO PLAN AND ELEVATIONS FOR LOCATION. WM WOMEN'S FULL FORM MANNEQUIN NEW REFER TO PLAN AND ELEVATIONS FOR LOCATION. WW WHITE WARDROBER TBD BY OWNER -NEW PACSUN G.C.REFER TO PLAN AND ELEVATIONS FOR LOCATION. SCHEDULES A701 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/03/23 2 2 2 TRANSFORMER L-9 L-1S L-1S L-1S L-1S L-1S L-9 L-9 L-9L-9L-9 L-9 L-9 L-9 L-9L-9 L-6S L-6S L-6S L-6 L-6 L-5 L-5 L-5 L-5 L-5 L-5L-5L-5L-5 L-5 L-5 L-1 L-1 L-6 L-10 L-10 L-10 L-10 L-10 L-10 LE D E X I T S I G N LE D EX I S T I N G LE D E X I T S I G N LE D EXI S T I N G LED EXIT SIGN LED EXISTING LED EXIT SIGNLED EXISTING LED EXIT SIGN LED EXISTING LED EXIT SIGN LED EXISTING L-7L-7 L-7 L-7 L-7 L-7 L-7 L-7 L-7 L-7 L-10 L-10 L-4 L-4L-4L-4 FITTING ROOMS 253 SQ. FT. @ 9'-6" A.F.F. ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/25/23 07/24/23 BUILDING COMMENTS Project Number: | Project Manager: 7328 E Stetson Dr., Scottsdale, AZ 85251 P: 480.626.7072 | ardebilieng.com KR22609 36618REGISTERED P R O FESSIONAL E N G I N E ER FA IS A L H ELHAL I S M ECHA N I C A LS T A TE OF CA L I F O R NIA 7/ 2 5 / 2 3 M0.1 ’ ’ ’ MECHANICAL SCHEDULES, PLANS, AND DETAILS ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS Project Number: | Project Manager: 7328 E Stetson Dr., Scottsdale, AZ 85251 P: 480.626.7072 | ardebilieng.com KR22609 36618REGISTERED P R O FESSIONAL E N G I N E ER FA IS A L H ELHAL I S M ECHA N I C A LS T A TE OF CA L I F O R NIA 6/ 2 9 / 2 3 M1.0 MECHANICAL SPECIFICATIONS ” ” DF S E0.1 ELECTRICAL SPECIFICATIONS & SYMBOLS Project Number: | Project Manager: 7328 E Stetson Dr., Scottsdale, AZ 85251 P: 480.626.7072 | ardebilieng.com HK22609 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 6/ 3 0 / 2 3 E0.2 ELECTRICAL INTERIOR LIGHTING T-24 Project Number: | Project Manager: 7328 E Stetson Dr., Scottsdale, AZ 85251 P: 480.626.7072 | ardebilieng.com HK22609 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/25/23 07/24/23 BUILDING COMMENTS 7/25/23 7328 E. STETSON DR. PATRICK CRONAN SCOTTSDALE, AZ 85251 480-626-7270 07/25/2023 PATRICK CRONAN 7328 E. STETSON DR. SCOTTSDALE, AZ 85251 480-626-7270 07/25/2023 22197 ARDEBILI ENGINEERING ARDEBILI ENGINEERING Santa Anita, CA Santa Anita, CA ENTIRE SHEET E0.3 ELECTRICAL LIGHTING CONTROL DEVICE CUT SHEETS Project Number: | Project Manager: 7328 E Stetson Dr., Scottsdale, AZ 85251 P: 480.626.7072 | ardebilieng.com HK22609 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 6/ 3 0 / 2 3 DIMMABLE OCCUPANCY SENSOR SWITCH DIMMABLE OCCUPANCY SENSOR SWITCH (CONT'D) DIMMING POWER PACK DIMMING POWER PACK (CONT'D) LOW VOLTAGE CEILING SENSOR LOW VOLTAGE CEILING SENSOR (CONT'D) OCCUPANCY SENSOR SWITCH OCCUPANCY SENSOR SWITCH (CONT'D) OVERRIDE SWITCH OVERRIDE SWITCH (CONT'D) E1.0 LIGHTING FLOOR PLAN Project Number: | Project Manager: 7328 E Stetson Dr., Scottsdale, AZ 85251 P: 480.626.7072 | ardebilieng.com HK22609 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/25/23 07/24/23 BUILDING COMMENTS 7/25/23 0.5 0.5 0.1 0.4 0.9 1.2 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 1.6 0.3 1.6 1.0 0.1 0.1 0.1 0.6 3.0 0.7 0.3 0.1 0.9 0.1 0.1 2.1 2.5 0.3 0.3 0.1 1.4 0.1 0.1 0.4 0.4 0.4 0.2 0.2 0.1 0.2 0.6 0.2 0.1 0.4 0.5 0.2 0.4 2.7 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.3 4.7 0.6 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 4.3 0.3 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.3 0.2 0.1 0.2 0.3 0.3 0.2 0.2 0.3 4.7 0.1 0.1 0.1 0.3 1.8 3.3 0.4 0.2 0.2 0.3 0.1 0.1 0.1 0.3 1.9 3.5 0.5 0.2 0.2 0.2 0.1 0.2 0.4 0.5 0.7 0.6 0.3 0.2 0.2 0.4 4.4 4.3 0.5 3.0 0.6 0.6 0.3 0.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.8 EM @ 10' EM @ 10' EM @ 10' EM @ 10'EM @ 10' EM @ 9' EM @ 9' EM @ 9' EM @ 10' EM @ 10' EM @ 12'EM @ 12'EM @ 12' EM @ 12' EM @ 12' EM @ 12'EM @ 12' EM @ 12' EM @ 12' EM @ 12'EM @ 12' EM @ 12' EM @ 12' EM @ 12' Statistics Description Symbol Avg Max Min Max/Min Avg/Min Calc Zone #1 0.6 fc 4.8 fc 0.0 fc N/A N/A Schedule Symbol Label Quantity Manufacturer Catalog Number Description Number Lamps Lumens Per Lamp Light Loss Factor Wattage EM 24 DUAL-LITE LZxx-03L LED EMERGENCY LUMINAIRE 1 155 1 3 E1.1 EMERGENCY LIGHTING PHOTOMETRIC PLAN Project Number: | Project Manager: 7328 E Stetson Dr., Scottsdale, AZ 85251 P: 480.626.7072 | ardebilieng.com HK22609 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 6/ 3 0 / 2 3 MW FRIDGE LOCKERS HA R D W A R E B I N 24x48 24x48 LA D D E R S BA R B I N PR O C E S S I N G D E S K +4 2 " A . F . F . 24x48 24x48 24x48 24x48 24x48 24x48 E2.0 POWER FLOOR PLAN Project Number: | Project Manager: 7328 E Stetson Dr., Scottsdale, AZ 85251 P: 480.626.7072 | ardebilieng.com HK22609 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 07/25/23 07/24/23 BUILDING COMMENTS 7/25/23 E3.0 ONE-LINE DIAGRAM Project Number: | Project Manager: 7328 E Stetson Dr., Scottsdale, AZ 85251 P: 480.626.7072 | ardebilieng.com HK22609 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS 6/ 3 0 / 2 3 ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS Project Number: | Project Manager: 7328 E Stetson Dr., Scottsdale, AZ 85251 P: 480.626.7072 | ardebilieng.com KR22609 36618REGISTERED P R O FESSIONAL E N G I N E ER FA IS A L H ELHAL I S M ECHA N I C A LS T A TE OF CA L I F O R NIA 6/ 2 9 / 2 3 P0.1 PLUMBING SCHEDULES ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS Project Number: | Project Manager: 7328 E Stetson Dr., Scottsdale, AZ 85251 P: 480.626.7072 | ardebilieng.com KR22609 36618REGISTERED P R O FESSIONAL E N G I N E ER FA IS A L H ELHAL I S M ECHA N I C A LS T A TE OF CA L I F O R NIA 6/ 2 9 / 2 3 P0.2 PLUMBING TITLE-24 COMPLIANCE MW FRIDGE B.O.H. 824 SQ. FT. @ 11'-0" A.F.F. HALLWAY 152 SQ. FT. @ 9'-6" A.F.F. FITTING ROOMS 253 SQ. FT. @ 9'-6" A.F.F. TRANSFORMER TOILET ROOM 63 SQ. FT. TOILET ROOM 63 SQ. FT. PR O C E S S I N G D E S K +4 2 " A . F . F . 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x4824x4824x4824x4824x48 HA R D W A R E B I N BA R B I N LA D D E R S 24x48 24x48 24x48 24x48 HA R D W A R E B I N BA R B I N LOCKERS DSL MW FRIDGE B.O.H. 824 SQ. FT. @ 11'-0" A.F.F. HALLWAY 152 SQ. FT. @ 9'-6" A.F.F. FITTING ROOMS 253 SQ. FT. @ 9'-6" A.F.F. TRANSFORMER TOILET ROOM 63 SQ. FT. TOILET ROOM 63 SQ. FT. PR O C E S S I N G D E S K +4 2 " A . F . F . 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x4824x4824x4824x4824x48 HA R D W A R E B I N BA R B I N LA D D E R S 24x48 24x48 24x48 24x48 HA R D W A R E B I N BA R B I N LOCKERS DSL ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS Project Number: | Project Manager: 7328 E Stetson Dr., Scottsdale, AZ 85251 P: 480.626.7072 | ardebilieng.com KR22609 36618REGISTERED P R O FESSIONAL E N G I N E ER FA IS A L H ELHAL I S M ECHA N I C A LS T A TE OF CA L I F O R NIA 6/ 2 9 / 2 3 P1.0 PLUMBING FLOOR PLANS ISSUE DATE: 05/01/2023 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: AREA: 5,294 SQ. FT. REVIEWED BY: JN ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD DATE THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 TITLE: SHEET NUMBER: STORE NO. 37 LANDLORD: THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 X 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS Project Number: | Project Manager: 7328 E Stetson Dr., Scottsdale, AZ 85251 P: 480.626.7072 | ardebilieng.com KR22609 36618REGISTERED P R O FESSIONAL E N G I N E ER FAI S A L H ELHAL I S M ECHA N I C A LS T A TE OF CA L I F O R NIA 6/ 2 9 / 2 3 ’ ” ’ “ ” ’” “ ” ” P2.0 PLUMBING SPECIFICATIONS WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): DATE TITLE: SHEET NUMBER: LANDLORD: X CARUSO TURLEY SCOTT INC Tempe, Arizona 85281 (480) 774-1700 (774-1701 FAX) 1215 West Rio Salado Parkway, Suite 200 consulting structural engineers www.ctsaz.com ISSUE DATE: 05/01/2023 AREA: 5,294 SQ. FT. REVIEWED BY: JN PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 STORE NO. 37 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS G.S.N. S1.1 GENERAL STRUCTURAL NOTES Applies unless noted otherwise on drawingsABBREVIATIONS DA V I D S . TROX E L L 06-27-23 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): DATE TITLE: SHEET NUMBER: LANDLORD: X CARUSO TURLEY SCOTT INC Tempe, Arizona 85281 (480) 774-1700 (774-1701 FAX) 1215 West Rio Salado Parkway, Suite 200 consulting structural engineers www.ctsaz.com ISSUE DATE: 05/01/2023 AREA: 5,294 SQ. FT. REVIEWED BY: JN PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 STORE NO. 37 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS FLOOR AND CEILING FRAMING PLAN S2.1 SCALE:1/4" = 1'-0"SCALE:1/4" = 1'-0" DA V I D S . TROX E L L 06-27-23 WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS NEED TO BE APPROVED BY TUMI CONSTRUCTION MANAGER FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. CONTRACTOR'S NOTES: REVISION LOCATION: PROJECT INFORMATION: ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): DATE TITLE: SHEET NUMBER: LANDLORD: X CARUSO TURLEY SCOTT INC Tempe, Arizona 85281 (480) 774-1700 (774-1701 FAX) 1215 West Rio Salado Parkway, Suite 200 consulting structural engineers www.ctsaz.com ISSUE DATE: 05/01/2023 AREA: 5,294 SQ. FT. REVIEWED BY: JN PROJECT NUMBER: 8566 - 22 DRAWN BY: EM / AD THE SHOPS SANTA ANITA DONNA GUERRERO (626) 462-8510 400 SOUTH BALDWIN AVE., SUITE 231, ARCADIA, CALIFORNIA 91007 THE SHOPS AT SANTA ANITA 400 SOUTH BALDWIN AVENUE, SPACES H-12, H-13, AND H-14 ARCADIA, CALIFORNIA 91007 STORE NO. 37 05/02/23 LANDLORD COMMENTS 06/20/23 BUILDING COMMENTS DETAILS S3.1 DA V I D S . TROX E L L 06-27-23