Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
400 S Baldwin Ave - 2023 - Life 4 Cuts
AC AIR CONDITIONING ACC ACCESSIBLE ACT ACOUSTICAL CEILING TILE ADJ ADJUSTABLE AFF ABOVE FINISHED FLOOR AHJ AUTHORITIES HAVING JURISDICTION AMP AMPERE AOR ARCHITECT OF RECORD APPROX APPROXIMATE BOH BACK OF HOUSE BLDG BUILDING CAB CABINET CKT CIRCUIT CL CENTER LINE CLG CEILING CLR CLEAR OR CLEARANCE COL COLUMN COMP COMPARTMENT CONST CONSTRUCTION CONT CONTINUOUS CTR CENTER CW COLD WATER CWF COLD WATER FILTERED CX COMMISSIONING CXA COMMISSIONING AGENT DEG DEGREES DET DETAIL DIA DIAMETER DISP DISPENSER DIM DIMENSION DM DESIGN MANAGER DN DOWN DWG(S) DRAWING(S) EA EACH EC ELECTRICAL CONTRACTOR EG EXHAUST GRILLE EL ELEVATION ELEC ELECTRICAL EM EMERGENCY EQ EQUAL EQUIP EQUIPMENT EXIST OR (E) EXISTING EXP EXPOSED EXT EXTERIOR FC FIXTURE CONTRACTOR/INSTALLER FCO FLOOR CLEANOUT FD FLOOR DRAIN FF&E FURNITURE, FIXTURE AND EQUIPMENT F&I FURNISH AND INSTALL FIN FINISH FLR FLOOR FOH FRONT OF HOUSE FRP FIBERGLAS REINFORCED PANEL FS FLOOR SINK FT FOOT OR FEET GC GENERAL CONTRACTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GND GROUND HC HOLLOW CORE HDW HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HR HOUR HS HAND SINK HT HEIGHT HVAC HEATING, VENTILATING AND AIR CONDITIONING HW HOT WATER ID INSIDE DIAMETER LC LICENSEE LL LANDLORD LV LOW VOLTAGE MAX MAXIMUM MC MECHANICAL CONTRACTOR MECH MECHANICAL MEP MECHANICAL, ELECTRICAL AND PLUMBING MFR MANUFACTURER MIN MINIMUM MS MOP SINK NIC NOT IN CONTRACT NTS NOT TO SCALE OA OVER ALL OC ON CENTER OD OUTSIDE DIAMETER PC PLUMBING CONTRACTOR PD PRODUCTION DESIGNER PDM PROJECT DEVELOPMENT MANAGER PLAM PLASTIC LAMINATE POS POINT OF SALE R RADIUS REF REFERENCE REQ(‘D) REQUIRE(D) REV REVISION RG RETURN GRILLE RND ROUND RT ROOF TOP SC SOLID CORE SF SQUARE FEET SHT SHEET SIM SIMILAR SPEC SPECIFICATION SQ SQUARE SST STAINLESS STEEL SUSP SUSPENDED TEL TELEPHONE TEMP TEMPORARY TW TEMPERED WATER TYP TYPICAL UC UNDERCOUNTER UNO UNLESS NOTED OTHERWISE VD VENDOR DIRECT VERT VERTICAL VIF VERIFY IN FIELD W SANITARY WASTE WH WATER HEATER WP WEATHER PROOF WCO WALL CLEANOUT WD WOOD WDW WINDOW PTD PAINTED GI GALVANIZED IRON UON UNLESS OTHERWISE NOTED X'-X" X'-X" X'-X" CEILING HEIGHT CHANGE SYMBOL CEILING FINISH AND HEIGHT SYMBOL CHANGE IN FLOOR FINISH EXTENT OF FINISH BASE FINISH WALL FINISH XX-99 XX-99 XXXX XXXX XXXX WALL FINISH SPECIAL FINISH FLOOR FINISH EXTENT OF FINISH SIM A11.01 A MILLWORK SCHEDULE TAG (IF USED) REVISION REFERENCE MILLWORK DESCRIPTION OF SIMILAR OR OPPOSITE LOCATION ON ROW WHERE SHOWN AREA TO BE DETAILED SHEET WHERE SHOWN DETAIL NUMBER SHEET WHERE SHOWN DIRECTION OF ELEVATION 1 XX A WALL TYPE REFERENCE WINDOW REFERENCE NUMBER (REFER TO WINDOW SCHEDULE) 05120 STRUCTURAL STEEL SPEC SECTION KEY NOTE XX ROW OF ELEVATION SHEET WHERE SHOWN AX.XX.X X EQUIPMENT NUMBER (REFER TO MILLWORK SHEETS) XXXXX ALIGN SHEET NOTE DOOR NUMBER (WITH SCHEDULE) ALIGN WITH ESTABLISHED SURFACES XXXXXX XX EGRESS PATH SECONDARY EGRESS PATH PRIMARY ROOM NAME COLUMN GRID NEW PARTITION ROOM NUMBER REFERENCE TO PARTITION TYPE ELEVATION DATUM POINT SCOPE OF WORK A 04F06 OFFICE X X XXX XXXX SECTION SYMBOLAX.XX X LINEAR DIFFUSER RETURN AIR SUPPLY AIR EXHAUST FAN FIRE SPRINKLER ACCESS DOOR ACOUSTICAL CEILING AND GRID GYPSUM BOARD FHC FEC FV FVC WALL MOUNTED FIRE EXTINGUISHER CABINET WALL MOUNTED FIRE VALVE CABINET WALL MOUNTED FIRE VALVE WALL MOUNTED FIRE EXTINGUISHER WALL MOUNTED FIRE HOSE CABINET FE C-33483 Date Description Project Name Project Number Description ARCHITECT: SECONEA 12440 Firestone Blvd. Suite 1017 Norwalk, CA 90650 T: 714.321.9545 www.seconea.com Info@seconea.com LEGAL NOTES: THE DRAWINGS AND SPECIFICATIONS, IDEAS, AND DESIGNS ARE AND SHALL REMAIN THE PROPERTY OF SECONEA, INC. NO PART THEREOF SHALL BE COPIED OR USED WITH ANY OTHER WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT THE WRITTEN CONSENT OF SECONEA, INC. SECONEA, INC. WAIVES ANY AND ALL RESPONSIBILITY AND LIABILITY FOR PROBLEMS WITCH ARISE FROM FAILURE TO FOLLOW THESE PLANS, SPECIFICATIONS, AND DESIGN INTENT THEY CONVEY, OR FOR PROBLEMS WHICH ARISE FROM OTHERS' FAILURE TO OBTAIN AND/OR FOLLOW THE DESIGN PROFESSIONAL'S GUIDANCE WITH RESPECT TO ANY ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR CONFLICTS WHICH ARE ALLEGED. ©2023 SECONEA 6-30-2025 A0.01 DRAWING INDEX & PROJECT INFORMATION 23_A12 LIFE 4 CUTS - TENANT IMPROVEMENTS LIFE 4 CUTS 400 S BALDWIN AVE. SUITE #T30, ARCADIA, CA 91007 LIFE 4 CUTS - TENANT IMPROVEMENTS 400 S BALDWIN AVE. SUITE #T30, ARCADIA, CA 91007 PROJECT INFORMATION VICINITY MAP APPLICABLE CODES TYPE OF CONSTRUCTION: USE: TYPE II-B, FULLY-SPRINKLERED SHOPPING CENTER (COVERED MALL BUILDING) (E) BUILDING INFORMATION SITE INFORMATION PROJECT ADDRESS: PARCEL NUMBER(APN): ZONE: USE TYPE & DESCRIPTION: SANTA ANITA MALL 400 S BALDWIN AVE. SUITE #T30, ARCADIA, CA 91007 5775031043 C-R (REGIONAL COMMERCIAL) SHOPPING CENTERS (REGIONAL) DRAWING INDEX ABBREVIATIONSGRAPHIC SYMBOLS OWNER/ TENANT: LANDLORD: ARCHITECT: ELECTRIC ENGINEER: PROJECT DIRECTORY VENTURE 2023, INC. 400 S BALDWIN AVE. SUITE T30 ARCADIA, CA 91007 RIDERWOOD USA, INC. (CONTACT: KARLA ALBA) 400 S BALDWIN AVE ARCADIA, CA 91007 818.438.0706 SECONEA ARCHITECTS 12440 FIRESTONE BLVD STE #1017 NORWALK, CA 90650 714.321.9545 PC ENGINEERING 2975 WILSHIRE BLVD. #530 LOS ANGELES, CA 90010 213.427.3605 PLAN CHECK SET #1 7/21/2023 PROJECT SITE STE #T30: TENANT IMPROVEMENT NEW USE: PROJECT SCOPE AREA/LEASED AREA: OCCUPANCY CLASSIFICATION: INSTANT PHOTO BOOTHS 645 SF M:MERCHANTILE B: BUSINESS S-1: STORAGE 2022 CALIFORNIA BUILDING CODE, TITLE 24 PART 2 2022 CALIFORNIA PLUMBING CODE, TITLE 24 PART 5 2022 CALIFORNIA MECHANICAL CODE, TITLE 24 PART 4 2022 CALIFORNIA ELECTRIC CODE, TITLE 24 PART 3 2022 CALIFORNIA GREEN BUILDING STANDARDS* 2022 CALIFORNIA ENERGY EFFICIENCY STANDRARDS CODE * PROJECT IS NONRESIDENTIAL ALTERATIONS WITH A PERMIT VALUATION LESS THAN $200,000 AND IS EXEMPTED PER THE CAL GREEN CODE SEC 301.3 SCOPE OF WORK THIS PROJECT INCLUDES 645 SF OF INTERIOR TENANT IMPROVEMENTS FOR INSTANT PHOTO KIOSK BOOTH USE IN THE EXISTING SHOPPING CENTER BUILDING. TENANT IMPROVEMENTS INCLUDE CONSTRUCTION AND INSTALLATION OF NEW 7'-6" HEIGHT NON-LOAD BEARING PARTITIONS, DUPLEX OUTLETS AND LIGHT FIXTURES, AND FINISHES, AS INDICATED. GENERAL NOTES 1. ALL WORK PERFORMED SHALL COMPLY WITH THE CONTRACT DOCUMENTS INCLUDING THESE GENERAL NOTES. THE CONTRACTOR SHALL COORDINATE THE INTENT OF THE GENERAL NOTES WITH ALL TRADES. ALL WORK PERFORMED SHALL COMPLY WITH CODES, LAWS, ORDINANCES, RULES, AND REGULATIONS OF PUBLIC AUTHORITIES GOVERNING THE WORK. 2. CONTRACTOR SHALL OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED BY PUBLIC AUTHORITIES GOVERNING THE WORK. 3. CONTRACTOR SHALL REVIEW DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND CONFIRM THAT WORK IS BUILDABLE AS SHOWN. REPORT ANY CONFLICTS OR OMISSIONS TO THE ARCHITECT FOR CLARIFICATION PRIOR TO PERFORMING ANY WORK IN QUESTIONS. SUBMIT REQUESTS FOR SUBSTITUTIONS,REVISIONS, OR CHANGES TO ARCHITECT FOR REVIEW PRIOR TO PURCHASE, FABRICATION OR INSTALLATION. 4. THE ORGANIZATION OF THE DRAWINGS SHALL NOT CONTROL THE CONTRACTOR IN DIVIDING THE WORK AMONG SUBCONTRACTORS OR IN ESTABLISHING THE EXTENT OF WORK TO BE PERFORMED BY ANY TRADE. 5. CONTRACTOR SHALL COORDINATE WORK WITH THE OWNER AND LANDLORD, INCLUDING SCHEDULING TIME AND LOCATIONS FOR DELIVERIES, BUILDING ACCESS, USE OF BUILDING SERVICES AND FACILITIES, AND USE OF ELEVATORS. MINIMIZE DISTURBANCE OF BUILDING FUNCTIONS AND OCCUPANTS. 6. OWNER WILL PROVIDE WORK NOTED "BY OTHERS" OR "NIC" UNDER SEPARATE CONTRACT. INCLUDE SCHEDULE REQUIREMENTS IN CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE TO ASSURE ORDERLY SEQUENCE OF INSTALLATION 7. CONTRACTOR SHALL COORDINATE TELECOMMUNICATIONS, DATA AND SECURITY SYSTEM INSTALLATIONS, UNO 8. THE STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION OF STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL WORK. SHOULD THERE BE A DISCREPANCY BETWEEN THE ARCHITECTURAL DRAWINGS AND THE CONSULTING ENGINEERS' DRAWINGS THAT WOULD CAUSE AN AWKWARD INSTALLATION, IT SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION PRIOR TO INSTALLATION OF SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST. 9. CONTRACTOR SHALL MAINTAIN EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES, AND ALARMS IN CONFORMANCE WITH CODES AND ORDINANCES. 10. PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE. 11. MAINTAIN WORK AREAS SECURE AND LOCKABLE DURING CONSTRUCTION. COORDINATE WITH TENANT AND LANDLORD TO ENSURE SECURITY. 12. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS, GRADES AND CONDITIONS AT SITE PRIOR TO COMMENCING THE WORK, AND REPORT ANY DISCREPANCIES TO THE ARCHITECT IN WRITING. 13. PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE, UNLESS OTHERWISE NOTED. MAINTAIN DIMENSIONS MARKED "CLEAR". ALLOW FOR THICKNESS OF FINISHES. 14. COORDINATE AND PROVIDE BACKING FOR MILLWORK AND ITEMS ATTACHED OR MOUNTED TO WALLS OR CEILINGS. 15. WHERE EXISTING ACCESS PANELS CONFLICT WITH CONSTRUCTION, RELOCATE PANELS TO ALIGN WITH AND FIT WITHIN NEW CONSTRUCTION. 16. WHERE A TYPICAL CONDITION IS DETAILED, IT SHALL BE UNDERSTOOD THAT ALL LIKE OR SIMILAR CONDITIONS ARE THE SAME UNLESS SPECIFICALLY NOTED OR DETAILED OTHERWISE. 17. UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4 INCH, UNLESS OTHERWISE NOTED. 18. CEILING HEIGHT DIMENSIONS ARE TO FINISHED CEILING SURFACES. 19. REFER TO MEP AND LOW VOLTAGE DRAWINGS FOR ROUTING OF CONDUIT, PIPING, DUCTWORK ETC. AT UNDERSIDE OF FLOOR SLABS AT TENANT SPACES. ROUTING TO BE ORTHOGONAL, AND LIKE ITEMS TO BE GANGED AND TO RUN PARALLEL WITH EVEN SPACING TYPICAL. EXACT ROUTING SHALL BE DETERMINED BY THE CONTRACTOR, AND LAYOUT SHOP DRAWINGS SUBMITTED FOR ARCHITECTURAL REVIEW AND APPROVAL PRIOR TO INSTALLATION. 20. CONTRACTOR SHALL PROVIDE ENGINEERING AS REQUIRED AND INSTALL ALL STIFFENERS, BRACING, BLOCKING, BACK-UP PLATES AND SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF ALL CASEWORK, TOILET ROOM ACCESSORIES, FIXTURES AND PARTITIONS AND ALL WALL- MOUNTED OR SUSPENDED MECHANICAL, ELECTRICAL OR MISCELLANEOUS EQUIPMENT AND FURNISHINGS. CONTRACTOR TO USE FIRE-RESISTIVE MATERIALS. 21. CHECK MECHANICAL DRAWINGS FOR MECHANICAL OPENING SIZES AND LOCATIONS. PIPING AND DUCTS PENETRATING STUD WALLS OR SHAFT WALLS SHALL BE PROVIDED WITH NECESSARY FRAMES, BRACING, AND ACOUSTICAL AND FIRE RETARDANT SEALANT AROUND THE OPENING. 22. CONTACT BETWEEN DISSIMILAR METALS SHALL BE PROTECTED. 23. PROVIDE ALL ACCESS PANELS REQUIRED FOR ALL JUNCTION BOXES, VALVES, CLEANOUTS, PLUGS, FILTERS, EQUIPMENT, AND ALL OTHER ITEMS REQUIRING SERVICE OR MAINTENANCE 24. THE DRAWINGS AND SPECIFICATIONS, IDEAS, AND DESIGNS ARE AND SHALL REMAIN THE PROPERTY OF SECONEA. NO PART THEREOF SHALL BE COPIED OR USED WITH ANY OTHER WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT THE WRITTEN CONSENT OF SECONEA. SECONEA WAIVES ANY AND ALL RESPONSIBILITY AND LIABILITY FOR PROBLEMS WITCH ARISE FROM FAILURE TO FOLLOW THESE PLANS, SPECIFICATIONS, AND DESIGN INTENT THEY CONVEY, OR FOR PROBLEMS WHICH ARISE FROM OTHERS' FAILURE TO OBTAIN AND/OR FOLLOW THE DESIGN PROFESSIONAL'S GUIDANCE WITH RESPECT TO ANY ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR CONFLICTS WHICH ARE ALLEGED. 25. GC TO REPLACE AIR-FILTERS FOR ALL EXISTING MECHANICAL EQUIPMENTS AT THE END OF CONSTRUCTION PHASE. 1. ENSURE SURFACES TO RECEIVE NEW FINISHES ARE CLEAN, TRUE AND FREE OF IRREGULARITIES. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. STARTING OF WORK INDICATES INSTALLER'S ACCEPTANCE OF SUBSTRATE. 2. REPAIR EXISTING SURFACES SCHEDULED TO REMAIN AS REQUIRED FOR THE APPLICATION OF NEW FINISHES. 3. UNLESS OTHERWISE NOTED, PROVIDE MINIMUM THREE-COAT PAINT SYSTEMS FOR EACH SUBSTRATE. 4. PROVIDE STRAIGHT, MDF WOOD BASE AT CARPETED AREAS AND COVE, TOP SET RESILIENT BASE AT AREAS OF RESILIENT FLOORING, UNLESS OTHERWISE NOTED. 5. PROVIDE LEVEL 4, UNO OR REFER TO PROJECT MANUAL FOR LEVEL OF FINISH FOR GYPSUM BOARD PARTITIONS/CEILINGS AS REQUIRED FOR SPECIFIED FINISHES. 6. ALL EXPOSED DUCTWORK, SPRINKLER PIPING MISC. PIPING & CONDUIT IN AREAS OF NO FINISHED CEILING ARE TO BE PAINTED TO MATCH STRUCTURE PAINT, UNO REFLECTED CEILING NOTES POWER & COM. NOTES FINISH NOTES 1. PRIOR TO CORING SLAB, REVIEW LOCATIONS WITH ARCHITECT AND COORDINATE LOCATIONS WITH OWNER. 2. COORDINATE INSTALLATION OF TELECOMMUNICATIONS, DATA AND SECURITY SYSTEMS. 3. VERIFY EQUIPMENT SPECIFICATIONS, POWER AND INSTALLATION REQUIREMENTS WITH MANUFACTURER TO ENSURE PROPER FIT AND FUNCTION. 4. VERIFY MOUNTING REQUIREMENTS OF ELECTRICAL, TELEPHONE AND OTHER EQUIPMENT. 5. GANG ADJACENT LIGHT SWITCHES AND COVER WITH A SINGLE PLATE. 6. INDICATED DIMENSIONS ARE TO THE CENTER LINE OF OUTLET OR SWITCH, OR CLUSTER OF OUTLETS OR SWITCHES, UNLESS OTHERWISE NOTED. 7. INSTALL OUTLETS ON OPPOSITE SIDES OF PARTITIONS IN SEPARATE STUD CAVITIES. DO NOT INSTALL BACK-TO-BACK. 8. PROVIDE MATCHING COVER PLATES, RECEPTACLES AND RELATED ITEMS. PROVIDE ONE-PIECE TYPE GANG COVER PLATES, UNLESS OTHERWISE NOTED. COLOR TO BE WHITE, UNLESS OTHERWISE NOTED. 9. IDENTIFY DEDICATED OR ISOLATED GROUND ELECTRICAL OUTLETS WITH A RED DOT. 10. PROVIDE LIGHT SWITCHING IN CONFORMANCE WITH TITLE 24 REQUIREMENTS. FOR ROOMS OR AREAS GREATER THAN 100 SQUARE FEET PROVIDE DOUBLE SWITCHES WITH EACH SWITCH CONTROLLING 50% OF LAMPS PER FIXTURE. 11. MOUNT STANDARD WALL OUTLETS, SWITCHES AND THERMOSTATS AT HEIGHTS REQUIRED BY TITLE 24 AND ADA GUIDELINES, UNLESS OTHERWISE NOTED. WHEN THERMOSTATS AND LIGHT SWITCH OCCUR TOGETHER, INSTALL BOTH ALIGNED HORIZONTALLY WITH CENTER LINE AT +3'-2" ABOVE FINISHED FLOOR. DEMOLITION NOTES 1. COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. 2. PROVIDE AND MAINTAIN BARRICADES, LIGHTING, AND GUARDRAILS AS REQUIRED BY APPLICABLE CODES AND REGULATIONS TO PROTECT OCCUPANTS OF BUILDING AND WORKERS. 3. ERECT AND MAINTAIN DUSTPROOF PARTITIONS AS REQUIRED TO PREVENT SPREAD OF DUST, FUMES, AND SMOKE, ETC. TO OTHER PARTS OF THE BUILDING. ON COMPLETION, REMOVE PARTITIONS AND REPAIR DAMAGED SURFACES TO MATCH ADJACENT SURFACES. 4. IF DEMOLITION IS PERFORMED IN EXCESS OF THAT REQUIRED, RESTORE EFFECTED AREAS AT NO COST TO THE OWNER. 5. REMOVE FROM SITE DAILY AND LEGALLY DISPOSE OF REFUSE, DEBRIS, RUBBISH, AND OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS. 6. REMOVE DESIGNATED PARTITIONS, COMPONENTS, BUILDING EQUIPMENT, AND FIXTURES AS REQUIRED FOR NEW WORK. 7. REMOVE ABANDONED HVAC EQUIPMENT, INCLUDING DUCT WORK. REFER TO MECHANICAL DEMOLITION AND/OR NEW WORK DRAWINGS FOR ADDITIONAL INFORMATION 8. REMOVE ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING AND DEVICES, UNLESS OTHERWISE NOTED. REFER TO ELECTRICAL, AV, ETC DEMOLITION AND/OR NEW DRAWINGS FOR ADDITIONAL INFORMATION. 9. REMOVE EXISTING FLOOR FINISHES AND PREPARE SUBFLOOR AS REQUIRED FOR NEW FLOOR FINISHES. 10. PATCH AND REPAIR SURFACES DAMAGED AS A RESULT OF ANY DEMO WORK PERFORMED. PATCH & REPAIR EXIST SURFACES AS REQ'D TO RECEIVE NEW FINISH. 3. LOCATE REGISTERS AND LIGHTING FIXTURES WITHIN GRID LINES. CENTER SPRINKLER HEADS, SPEAKERS, RECESSED FIXTURES, AND SIMILAR CEILING ELEMENTS IN ACOUSTICAL UNITS, UNLESS OTHERWISE NOTED. 4. FINISH HVAC DIFFUSERS, DRAPERY POCKETS, AND SPEAKER GRILLES TO MATCH ADJACENT FINISH, UNLESS OTHERWISE NOTED. 5. LOCATE REGISTERS AND LIGHTING FIXTURES WITHIN GRID LINES. CENTER SPRINKLER HEADS, SPEAKERS, RECESSED FIXTURES, AND SIMILAR CEILING ELEMENTS IN ACOUSTICAL UNITS, UNLESS OTHERWISE NOTED. 6. SUPPORT LIGHT FIXTURES AND AIR DIFFUSERS DIRECTLY BY WIRES TO THE STRUCTURE ABOVE. 1. DESIGN SUSPENDED CEILING FRAMING SYSTEMS TO RESIST A LATERAL FORCE OF 20 % OF THE WEIGHT OF THE CEILING ASSEMBLY AND ANY LOADS TRIBUTARY TO THE SYSTEM. USE A MINIMUM CEILING WEIGHT OF 5 POUNDS PER SQUARE FOOT TO DETERMINE THE LATERAL FORCE. 2. WHERE CEILING LOADS DO NOT EXCEED 5 POUNDS PER SQUARE FOOT AND WHERE PARTITIONS ARE NOT CONNECTED TO THE CEILING SYSTEM, THE FOLLOWING BRACING METHODS MAY BE EMPLOYED: 2.1. PROVIDE LATERAL SUPPORT BY METAL STUD OR ANGLE CONNECTED TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. PROVIDE THESE LATERAL SUPPORT POINTS 4 FEET ON CENTER, WITH THE FIRST POINT WITHIN 4' FROM EACH WALL. 2.2. ALLOW FOR LATERAL MOVEMENT OF THE SYSTEM. ATTACH MAIN RUNNERS AND CROSS RUNNERS AT TWO ADJACENT WALLS; MAINTAIN CLEARANCE BETWEEN THE WALL AND THE RUNNERS AT THE OTHER TWO WALLS. 2.3. PROVIDE VERTICAL SUPPORT AS REQUIRED IN BUILDING CODES. INADDITION, VERTICALLY SUPPORT ENDS OF RUNNERS WITHIN 8" OF DISCONTINUITIES SUCH AS MAY OCCUR WHERE THE CEILING IS INTERRUPTED BY A WALL. 2.4. SUPPORT LIGHT FIXTURES AND AIR DIFFUSERS DIRECTLY BY WIRES TO THE STRUCTURE ABOVE. UNDER SEPARATE PERMITS • FIRE SPRINKLERS 1. ARCHITECTURE A0.01 DRAWING INDEX & PROJECT INFORMATION A0.31 ACCESSIBILITY REQUIREMENTS & DETAILS A0.32 ACCESSIBILITY NOTES A0.33 ACCESSIBILITY NOTES 2 A0.80 LIFE SAFETY/EGRESS PLAN A1.01 DEMO AND CONSTRUCTION PLANS A1.02 REFLECTED CEILING PLAN A3.01 INT ELEVATIONS A8.11 DETAILS AND DOOR TYPE AND SCHEDULE 2. ELECTRICAL E-1 GENERAL NOTES, SCHEDULES,SITE PLAN & SINGLE LINE DIAGRAM E-2 POWER PLAN & LIGHTING PLAN E-3 TITLE 24 COMPLIANCE FORMS LOCATION MAP PROJECT SITE 07/21/2023 PLAN CHECK SET #1 3" 3" 1" 3/ 4 " 1/ 2 " M A X 1/ 2 " M I N EXIT 3" 3" 1" 1/ 2 " EXIT 1" 1/ 2 " 3 2 TO 1 4 FF 5 WALL 60 " M A X 3" 3" 1" 1/ 2 " ROUTE 1" 1/ 2 " EXIT EXIT 1" 3" 4" 1/ 2 " 1" 1" 1/ 2 " STAIR DOWN AT EXITS LEADING TO EXTERIOR OF BUILDING AT LOBBY AREAS WITH DOOR LEADING INTO RATED CORRIDOR TO BUILDING EXIT AT ROOM/AREA EXITS LEADING INTO RATED CORRIDORS TO BUILDING EXITS AT CORRIDOR SIDE OF EXIT STAIRS ON ALL UPPER FLOORS EXIT SIGNAGE IDENTIFICATION WITH RASIED LETTERS AND BRAILLE. BRAILLE TO MATCH BACKGROUND FINISH. CHARACTERS, SYMBOLS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. CHARACTERS AND SYMBOLS SHALL CONTRAST ON A PAINTED BACKGROUND. CHARACTERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO OF BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH TO HEIGHT RATIO OF BETWEEN 1:5 AND 1:10. CHARACTERS ON SIGNS SHALL BE RAISED 1/32" MIN. AND SHALL BE A CUSTOM ZAPF HUMANIST DEMI-BOLD UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE COMPLYING WITH 1117B.5.6. RAISED CHARACTERS AND BRAILLE SHALL BE A MIN. OF 5/8" AND A MAX OF 2" HIGH. ACRYLIC PHOTOPOLYMER PANEL TO BE MOUNTED ON A 1/8" THK. ACRYLIC SPACER PANEL. CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE IS REQUIRED IN OTHER PORTIONS OF THESE STANDARDS. DOTS SHALL BE 1/10" ON CENTERS IN CASE CELL WITH 2/10" SPACE BETWEEN CELLS, MEASURED FROM THE SECOND COLUMN OF DOTS IN THE FIRST CELL TOTHE FIRST COLUMN OF DOTS IN THE SECOND CELL. DOTS SHALL HAVE A MIN OF 1/40" ABOVE THE BACKGROUND. WHERE PERMANENT INDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. MOUNTING HEIGHT SHALL BE 60" ABOVE THE FINISH FLOOR TO THE CENTER OF THE SIGN. MOUNTING LOCATION SHALL BE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3" OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR. CENTER SIGN ON 18"WIDE x 18" DEEP CLEAR SPACE. 2 3 4 5 . 48 " M I N . 48 " M I N . 48 " M I N . 48 " M I N . 60 " M A X . 60 " M A X . 60 " M A X . 60 " M A X 1 18 " M I N . 18 " M I N . 48" MIN.48" MIN.DOORS AT ADJACENT WALLS DOORS AT OPPOSITE WALLS 48" MIN. 18 " M I N . 12 " M I N . 48" MIN. 12 " M I N . 12 " M I N . PROVIDE THIS ADDITIONAL SPACE IF DOOR IS EQUIPPED WITH BOTH A LATCH AND A CLOSER BOTH DOORS OPEN OUT NOTES: FOR DOORS SERVING OTHER THAN A REQUIRED EXIT STAIRWAY DOOR IN SERIES 48 " M I N . (D) FRONT APPROACH SLIDING DOORS 48 " M I N . (G) FRONT APPROACH FOLDING DOORS 42 " M I N . 54" MIN. (E) SLIDE SIDE APPROACH SLIDING/FOLDING DOORS 42 " M I N . (H) SLIDE SIDE APPROACH FOLDING DOORS 54" MIN. (F) LATCH SIDE APPROACH SLIDING DOORS 42 " M I N . 24" MIN. (H) LATCH SIDE APPROACH FOLDING DOORS 42 " M I N . 24" MIN. NOTE: ALL DOORS IN ALCOVES SHALL COMPLY WITH THE CLEARANCES FOR FRONT APPROACHES MIN. 24". 54" MIN. PUSH SIDE 44 " M I N . 36" MIN.60 " M I N . PULL SIDE 48" MIN. IF DOOR HAS BOTH A LATCH AND A CLOSER HINGE APPROACH PUSH SIDE 44 " M I N . 60 " M I N . PULL SIDE LATCH APPROACH 24" MIN. * * * 24" MIN. 22" MIN. 32" MIN.32" MIN. 32" MIN.32" MIN. 32" MIN.32" MIN. 60 " M I N . (a) PULL SIDE (INTERIOR DOOR) 32" MIN. NOTE: PROVIDE BUMPER IN POCKET TO PREVENT DOOR FROM FULLY RECEDING (b) SLIDING DOOR (c) FOLDING DOOR 32" MIN. PULL SIDE CLEAR LEVEL LANDING PUSH SIDE CLEAR LEVEL LANDING PROVIDE 12" MIN. IF DOOR IS EQUIPPED WITH BOTH A LATCH AND A CLOSER NOTE: 2% MAX SLOPE AT EXTERIOR LANDINGS ONLY 48 " M I N . 60 " M I N . 12" 32" MIN. CLR.@INT.DOORS 18" MIN. CLEAR @ EXT. DOOR 24" MIN. CLEAR 10" MIN BOTTOM RAIL LEVER OR U-SHAPED HANDLE 36" TO 42" A.F.F FROM DOOR TO STOP90° MIN. 18" X > 8 " PULL SIDE * * * CLEAR LEVEL LANDING* 30 " M I N . 48" MIN. 19" MIN. 30" MIN.19 " M I N . 30 " M I N . 48 " M I N . 30" MIN.42" MIN. ACCESSIBLE PATH OF TRAVEL NOTE: X SHALL BE LESS THAN OR EQUAL TO 25 INCHES. Z SHALL BE GREATER THAN OR EQUAL TO X. WHEN X IS LESS THAN 20 INCHES, THEN Y SHALL BE 48 INCHES MAXIMUM. WHEN X IS 20 TO 25 INCHES, THEN Y SHALL BE 44 INCHES MAXIMUM. HIGH FORWARD REACH 24" MAX 34 " M A X . 46 " M A X . 30" 10" MAX 1' - 3 " M I N 48 " M A X . 30" MAX. SIDE REACH OVER AN OBSTRUCTION HIGH AND LOW SIDE REACH LIMITS 15 " M I N . 48 " M A X . 48" MIN.48" MIN . 30 " 48 " M A X . MAX. 21". MIN . 30 " Y X Z 48" MIN. X Z 48" MIN. MAXIMUM FORWARD REACH OVER AN OBSTRUCTION 48 " MAX. 10" MIN. 30" CLEAR FLOOR SPACE PARALLEL APPROACH CLOSETS 40 " M I N . 48 " M A X . MAX. 21". SHELVES NOTE: AT PASS THROUGH KITCHENS, A MIN. 40 INCH CLEAR PATH. AT 'U' SHAPED OR DEAD- END KITCHENS, 60 INCH MIN CLEAR. REACH DIAGRAMS APPLY TO EQUIPMENT AND REF/FREEZER CL R . 27 " M I N . 34 " M A X . 28 " M I N . MINIMUM CLEARANCES FOR SEATING AND TABLES T-SHAPE 180° TURNS CLEAR WIDTH FOR TWO WHEEL CHAIRS TO PASS PARALLEL THROUGH CORRIDOR 180° TURNS AROUND AN OBSTRUCTION WHEELCHAIR TURNING SPACE NOTE: * WHEN X < 48" ** WHEN X > 48" ALSO REFER TO OCCUPANT LOAD FOR REQUIRED EGRESS WIDTH. 60 " D I A . 42" *MIN.42" *MIN. 48 " M I N . 36 " M I N . * 36" MIN.*60" MIN. 36" MIN. *36" MIN. * 60 " M I N . 44 " M I N * * 44" MIN**CLR. 12" MIN. CLR. 12" MIN. 60 " M I N . C L R . CL R . 24 " M I N . 60" MIN. CLR. 'X' < 48" 60 " M I N . 36" MIN.* MA X . 24 " 4 8 " M I N . MA X . 24 " MIN. 32" MINIMUM CLEAR WIDTH FOR SINGLE WHEELCHAIR MIN. 32" FINISH FLOOR FINISH FLOOR CARPET 211:2 SLOPE MAX 2 1 . . 1/4" MAX. 1/2" MAX. AT 1:2 SLOPE .. 1/4" MAX. 1/2" MAX. AT 1:2 SLOPE FINISH FLOOR EVEN THRESHOLD . COMPRESSE D CARPET 1/4" MAX. BELOW THRESHOLD NOTE: CARPET SHALL BE SECURELY ATTACHED; HAVE A FIRM CUSHION, PAD OR BACKING OR NO CUSHION OR PAD; AND HAVE A LEVEL LOOP, TEXTURED LOOP, LEVEL-CUT PILE OR LEVEL- CUT/UNCUT PILE TEXTURE. THE MAXIMUM PILE HEIGHT SHALL BE 1/2 INCH A. THRESHOLD B. TRANSITION TYPE 1 C. TRANSITION TYPE 2 TRANSITION TYPE 1 OR 2 D. CARPET TRANSITION TYPE 1 E. CARPET TRANSITION TYPE 2 F. OPENINGS IN THE FLOOR DOMINANT DIRECTION OF TRAVEL . 1/2" MAX. LO N G D I M E N S I O N PE R P E N D I C U L A R T O DO M I N A N T DIR E C T I O N O F TR A V E L NOTE: OPENINGS SHALL NOT ALLOW PASSAGE OF A SPHERE MORE THAN 1/2" DIAMETER, EXCEPT AT AN ELEVATOR DOOR THRESHOLD. FIRE STROBE ELECTRICAL / DATA OUTLETS (SEE PLANS FOR LOCATIONS) DEVICES AT DOOR IN OPEN POSITION 2"2" MAX. TYP. 6" 6'- 8 " THERMOSTAT TELEPHONE (AS APPLICABLE) GANG OF DIMMER SWITCHES FLUORESCENT SWITCH (SECURITY DEVICE WHERE OCCURS) ALIGN TOP OF DEVICES T. O . O U T L E T B O X 38 " ( 4 8 " M A X . ) 1 7/8" OUTLINE OF DOOR IN OPEN POSITION NOTE: ALL DIMENSIONS TO CENTER LINE OF DEVICES U.O.N.; SECURITY CARD READER, KEY PAD AND OTHER DEVICES SHALL BE MOUNTED @ 3'-2" AFF; INTERCOM TO BE MOUNTED @ 3'-9" AFF.U.O.N.; FIRE ALARM BOXES TO BE MOUNTED BETWEEN 42" MIN. AND 48" MAX. AFF OUTLET OF THE BOX.; CENTER ALL DEVICES BELOW SWITCH. B. O . B O X 1' - 3 " DEVICES AT DOOR IN CLOSED POSTION 6" 2"2" MAX. TYP. THERMOSTAT FIRE STROBE TELEPHONE (AS APPLICABLE) GANG OF DIMMER SWITCHES ELECTRICAL / DATA OUTLETS (SEE PLANS FOR LOCATIONS) FLUORESCENT SWITCH (SECURITY DEVICE WHERE OCCURS) 6' - 8 " B. O . B O X 1'- 3 " 34 " - 4 4 " T. O . O F O U T L E T B O X 48 " M A X . ALIGN TOP OF DEVICES 1 7/8" C-33483 Date Description Project Name Project Number Description ARCHITECT: SECONEA 12440 Firestone Blvd. Suite 1017 Norwalk, CA 90650 T: 714.321.9545 www.seconea.com Info@seconea.com LEGAL NOTES: THE DRAWINGS AND SPECIFICATIONS, IDEAS, AND DESIGNS ARE AND SHALL REMAIN THE PROPERTY OF SECONEA, INC. NO PART THEREOF SHALL BE COPIED OR USED WITH ANY OTHER WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT THE WRITTEN CONSENT OF SECONEA, INC. SECONEA, INC. WAIVES ANY AND ALL RESPONSIBILITY AND LIABILITY FOR PROBLEMS WITCH ARISE FROM FAILURE TO FOLLOW THESE PLANS, SPECIFICATIONS, AND DESIGN INTENT THEY CONVEY, OR FOR PROBLEMS WHICH ARISE FROM OTHERS' FAILURE TO OBTAIN AND/OR FOLLOW THE DESIGN PROFESSIONAL'S GUIDANCE WITH RESPECT TO ANY ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR CONFLICTS WHICH ARE ALLEGED. ©2023 SECONEA 6-30-2025 A0.31 ACCESSIBILITY REQUIREMENTS & DETAILS 23_A12 LIFE 4 CUTS - TENANT IMPROVEMENTS LIFE 4 CUTS 400 S BALDWIN AVE. SUITE #T30, ARCADIA, CA 91007 NOT TO SCALEA0.31 15 ACCESSIBLE TACTILE SIGNAGE NTSA0.31 4 ACCESSIBLE VESTIBULES NOT TO SCALEA0.31 2 ACCESSIBLE DOOR CLR-SIDE APPROACH NOT TO SCALEA0.31 1 ACCESSIBLE DOOR CLR-FRONT APPROACH NOT TO SCALEA0.31 8 ACCESSIBLE MINIMUM REACH NOT TO SCALEA0.31 7 ACCESSIBLE CORRIDORS AND TURNING NOT TO SCALEA0.31 6 ACCESSIBLE FLOOR TRANSITIONS1 1/2" = 1'-0"A0.31 14 TYPICAL DEVICE MOUNTING DIAGRAM @ DOOR 07/21/2023 PLAN CHECK SET #1 SITE DEVELOPMENT & ACCESSIBLE ROUTE OF TRAVEL 1. ACCESSIBLE ROUTE OF TRAVEL IS DEFINED AS “A CONTINUOUS UNOBSTRUCTED PATH CONNECTING ACCESSIBLE ELEMENTS AND SPACES ON AN ACCESSIBLE SITE, BUILDING OR FACILITY THAT CAN BE NEGOTIATED BY A PERSON WITH A DISABILITY USING A WHEELCHAIR AND THAT IS ALSO SAFE FOR AND USABLE BY PERSONS WITH OTHER DISABILITIES, AND THAT IS CONSISTENT WITH THE DEFINITION OF “PATH OF TRAVEL”. (202) 2. AT LEAST ONE ACCESSIBLE ROUTE SHALL BE PROVIDED WITHIN THE SITE SHALL FROM PUBLIC TRANSPORTATION STOPS, ACCESSIBLE PARKING AND ACCESSIBLE PASSENGER LOADING ZONES , PUBLIC STREETS AND SIDEWALKS TO THE ACCESSIBLE BUILDING OR FACILITY ENTRANCE THEY SERVE. WHERE MORE THAN ONE ROUTE IS PROVIDED ALL ROUTES MUST BE ACCESSIBLE. (11B-206.2) 3. AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDINGS, ACCESSIBLE FACILITIES, ACCESSIBLE ELEMENTS AND ACCESSIBLE SPACES THAT ARE ON THE SAME SITE. (11B-206.2.2) 4. ACCESSIBLE ROUTES SHALL COINCIDE WITH OR BE LOCATED IN THE SAME AREA AS GENERAL CIRCULATION PATHS. AN ACCESSIBLE ROUTE SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, RESTROOMS, CLOSETS OR OTHER SPACES USED FOR SIMILAR PURPOSES, EXCEPT AS PERMITTED BY CHAPTER 10 (11B-206.3) 5.AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDING OR FACILITY ENTRANCES WITH ALL ACCESSIBLE SPACES AND ELEMENTS WITHIN THE BUILDING OR FACILITY. (11B-206.2.4) 6. IN NEW CONSTRUCTION OF BUILDINGS WHERE ELEVATORS ARE REQUIRED BY SECTION 11B-206.2.3, AND WHICH EXCEED 10,000 SQUARE FEET ON ANY FLOOR, AN ACCESSIBLE MEANS OF VERTICAL ACCESS VIA RAMP, ELEVATOR OR LIFT SHALL BE PROVIDED WITHIN 200 FEET OF TRAVEL OF EACH STAIR AND EACH ESCALATOR. IN EXISTING BUILDINGS THAT EXCEED 10,000 SQUARE FEET ON ANY FLOOR AND IN WHICH ELEVATORS ARE REQUIRED BY SECTION 11B-206.2.3, WHENEVER A NEWLY CONSTRUCTED MEANS OF VERTICAL ACCESS IS PROVIDED VIA STAIRS OR AN ESCALATOR, AN ACCESSIBLE MEANS OF VERTICAL ACCESS VIA RAMP, ELEVATOR OR LIFT SHALL BE PROVIDED WITHIN 200 FEET OF TRAVEL OF EACH NEW STAIR OR ESCALATOR. (11B-206.2.3.2) ACCESSIBLE PARKING 1. ACCESSIBLE PARKING SPACES COMPLYING WITH SECTION 11B-502 THAT SERVE A PARTICULAR BUILDING OR FACILITY SHALL BE LOCATED ON THE SHORTEST ACCESSIBLE ROUTE FROM PARKING TO AN ENTRANCE COMPLYING WITH SECTION 11B-206.4. WHERE PARKING SERVES MORE THAN ONE ACCESSIBLE ENTRANCE, PARKING SHALL BE DISPERSED AND LOCATED ON THE SHORTEST ACCESSIBLE ROUTE TO THE ACCESSIBLE ENTRANCES. EXCEPTION: 1 ALL VAN PARKING SPACES SHALL BE PERMITTED TO BE GROUPED ON ONE LEVEL WITHIN A MULTI-STORY PARKING FACILITY (11B-208.3.1) 2. CAR AND VAN PARKING SPACES SHALL COMPLY WITH SECTION 11B-502. WHERE PARKING SPACES ARE MARKED WITH LINES, WIDTH MEASUREMENTS OF PARKING SPACES AND ACCESS AISLES SHALL BE MADE FROM THE CENTER LINE OF THE MARKING. (11B-502.1) 3. CAR AND VAN PARKING SPACES SHALL BE 216 INCHES LONG MIN. CAR PARKING SPACES SHALL BE 108 INCHES WIDE MIN. AND VAN PARKING SPACES SHALL BE 144 INCHES MIN., SHALL BE MARKED TO DEFINE THE WIDTH AND SHALL HAVE AN ADJACENT ACCESS AISLE COMPLYING WITH SECTION 11B-502.3. (11B-502.2) 4. ACCESS AISLES SERVING CAR AND VAN PARKING SPACES SHALL BE 60 INCHES WIDE MIN. ACCESS AISLES SHALL EXTEND THE FULL REQUIRED LENGTH OF THE PARKING SPACE THEY SERVE. ACCESS AISLES SHALL ADJOIN AN ACCESSIBLE ROUTE. TWO PARKING SPACES SHALL BE PERMITTED TO SHARE A COMMON ACCESS AISLE. (11B-502.3). 5. ACCESS AISLES SHALL BE MARKED WITH A BLUE PAINTED BORDERLINE AROUND THEIR PERIMETER. THE AREA WITHIN SHALL BE MARKED WITH HATCHED LINES A MAX. 36 INCHES ON CENTER IN A COLOR CONTRASTING WITH THAT OF THE AISLE SURFACE. THE WORDS "NO PARKING" SHALL BE PAINTED ON THE SURFACE WITHIN EACH ACCESS AISLE IN WHITE LETTERS A MIN OF 12 INCHES IN HEIGHT AND LOCATED TO BE VISIBLE FROM ADJACENT VEHICULAR WAY. (11B-502.3.3) 6. ACCESS AISLES SHALL NOT OVERLAP THE VEHICULAR WAY. ACCESS AISLES SHALL BE PERMITTED TO BE PLACED ON EITHER SIDE OF THE PARKING SPACE=EXCEPT FOR VAN PARKING SPACES WHICH SHALL HAVE ACCESS AISLES LOCATED ON THE PASSENGER SIDE OF THE PARKING SPACES.(11B-502.3.4) 7. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE PARKING SPACES THEY SERVE. CHANGES IN LEVEL ARE NOT PERMITTED. SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED. (11B-502.4). 8. PARKING SPACES AND ACCESS AISLES SHALL BE DESIGNED SO THAT CARS AND VANS , WHEN PARKED, CANNOT OBSTRUCT THE REQUIRED CLEAR WIDTH OF ADJACENT ACCESSIBLE ROUTES. PARKING SPACES AND ACCESS AISLES SHALL BE DESIGNED SO THAT PERSONS USING THEM ARE NOT REQUIRED TO TRAVEL BEHIND PARKING SPACES OTHER THAN TO PASS BEHIND THE PARKING SPACE IN WHICH THEY PARKED. (11B-502.7) 9. A CURB OR WHEEL STOP SHALL BE PROVIDED IF REQUIRED TO PREVENT ENCROACHMENT OF VEHICLES OVER THE REQUIRED WIDTH OF ADJACENT ACCESSIBLE ROUTES. (11B-502.7.2) 10. PARKING SPACE IDENTIFICATION SIGNS SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1. SIGNS IDENTIFYING VAN PARKING SPACES SHALL CONTAIN ADDITIONAL LANGUAGE OR AN ADDITIONAL SIGN WITH THE DESIGNATION "VAN ACCESSIBLE". SIGNS SHALL BE 60 INCHES MIN ABOVE THE FINISH FLOOR OR GROUND SURFACE MEASURED TO THE BOTTOM OF THE SIGN. EXCEPTION:SIGNS LOCATED WITHIN AN ACCESSIBLE ROUTE SHALL BE A MIN. OF 80 INCHES ABOVE THE FINISH FLOOR OR GROUND SURFACE MEASURED TO THE BOTTOM OF THE SIGN. (11B-502.6). ADDITIONAL LANGUAGE OR AN ADDITIONAL SIGN BELOW THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL STATE "MINIMUM FINE $250."(11B-502.6.2) 11. PARKING IDENTIFICATION SIGNS SHALL BE REFLECTORIZED WITH A MIN AREA OF 70 SQUARE INCHES.(11B-502.6.1). PARKING SPACE IDENTIFICATION SIGN SHALL BE VISIBLE FROM EACH PARKING SPACE. SIGNS SHALL BE PERMANENTLY POSTED EITHER IMMEDIATELY ADJACENT TO THE PARKING SPACE OR WITHIN THE PROJECTED PARKING SPACE WIDTH AT THE HEAD END OF THE PARKING SPACE. SIGN MAY ALSO BE PERMANENTLY POSTED ON A WALL AT THE INTERIOR END OF THE PARKING SPACE. (11B-502.6.3) 12. AN ADDITIONAL SIGN SHALL BE POSTED EITHER ; 1) IN A CONSPICUOUS PLACE AT EACH ENTRANCE TO OFF-STREET PARKING FACILITIES, OR 2) IMMEDIATELY ADJACENT TO AN ON-SITE ACCESSIBLE PARKING AND VISIBLE FROM EACH PARKING SPACE. THE SIGN SHALL BE NOT LESS THAN 17 INCHES WIDE BY 22 INCHES HIGH.(11B-502.8) 13. THE ADDITIONAL SIGN SHALL CLEARLY STATE IN LETTERS WITH A MIN. HEIGHT OF 1 INCH THE FOLLOWING: "UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT OWNER'S EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT _______________OR BY TELEPHONING_____________ ." (BLANK SPACES ARE TO BE FILLED IN WITH APPROPRIATE INFORMATION AS A PERMANENT PART OF THE SIGN.)(11B-502.8.2) 14. EACH ACCESSIBLE CAR OR VAN SPACE SHALL HAVE A SURFACE IDENTIFICATION COMPLYING WITH EITHER SECTIONS 11B-502.6.4.1 OR 11B-502.6.4.2 11B-502.6.4.1. THE PARKING SPACE SHALL BE MARKED WITH AN INTERNATIONAL SYMBOL OF ACCESSIBILITY IN WHITE ON A BLUE BACKGROUND A MIN. OF 36 INCHES WIDE BY 36 INCHES HIGH. THE CENTERLINE OF THE ISA SHALL BE A MAX. 6 INCHES FROM THE CENTERLINE OF THE PARKING SPACE, ITS SIDES PARALLEL TO THE LENGTH OF THE PARKING SPACE AND ITS LOWER CORNER OR LOWER SIDE ALIGNED WITH THE END OF THE PARKING SPACE. 11B-502.6.4.2. THE PARKING SPACE SHALL BE OUTLINED OR PAINTED BLUE AND SHALL BE MARKED WITH AN INTERNATIONAL SYMBOL OF ACCESSIBILITY IN WHITE OR A SUITABLE CONTRASTING COLOR A MIN. OF 36 INCHES WIDE BY 36 INCHES HIGH. THE CENTERLINE OF THE ISA SHALL BE A MAX. 6 INCHES FROM THE CENTERLINE OF THE PARKING SPACE, ITS SIDES PARALLEL TO THE LENGTH OF THE PARKING SPACE AND ITS LOWER CORNER OR LOWER SIDE ALIGNED WITH THE END OF THE PARKING SPACE. 15. FOR EVERY SIX OR FRACTION OF SIX PARKING SPACES REQUIRED BY SECTION 11B-208.2 , AT LEAST ONE SHALL BE A VAN PARKING SPACE. (11B-208.2.4) PASSENGER DROP-OFF & LOADING ZONES 1. WHEN PROVIDED, PASSENGER DROP-OFF AND LOADING ZONES SHALL PROVIDE A VEHICULAR PULL-UP SPACE 96 INCHES WIDE MIN. AND 20 FEET LONG MIN. (11B-503.2) 2. WHERE PROVIDED, ONE PASSENGER DROP-OFF AND LOADING ZONE SHALL PROVIDE ACCESS AISLES COMPLYING WITH SECTION 11B-503 ADJACENT AND PARALLEL TO THE VEHICULAR PULL-UP SPACE. ACCESS AISLES SHALL ADJOIN AN ACCESSIBLE ROUTE AND SHALL NOT OVERLAP THE VEHICULAR WAY. (11B-503.3) AT LEAST 60 INCHES WIDE AND 20 FEET LONG ADJACENT AND PARALLEL TO THE VEHICLE PULL-UP SPACE. VEHICLE STANDING SPACES AND ACCESS AISLES SHALL BE LEVEL WITH SURFACE SLOPES NOT EXCEEDING 1:50 (2 PERCENT) IN ALL DIRECTIONS. IF THERE ARE CURBS BETWEEN THE ACCESS AISLE AND THE VEHICLE PULL-UP SPACE, THEN A CURB RAMP SHALL BE PROVIDED. (1131B.2.1, FIG 11B-24) 3. ACCESS AISLES SERVING VEHICLE PULL-UP SPACES SHALL BE 60 INCHES WIDE MIN. ACCESS AISLES SHALL EXTEND THE FULL LENGTH OF THE VEHICLE PULL-UP SPACE THEY SERVE. ACCESS AISLES SHALL BE MARKED WITH A PAINTED BORDERLINE AROUND THEIR PERIMETER. THE AREA WITHIN THE BORDERLINES SHALL BE MARKED WITH HATCHED LINES A MAX. 36 INCHES ON CENTER IN A COLOR CONTRASTING WITH THAT OF THE AISLE SURFACE. (11B-503.3.1, 11B-503.3.2, 11BH-503.3.3) 4. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE VEHICLE PULL-UP SPACE THEY SERVE. CHANGES IN LEVEL ARE NOT PERMITTED. EXCEPTION:SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED. VEHICLE PULL-UP SPACES, ACCESS AISLES SERVING THEM AND A VEHICULAR ROUTE FROM AN ENTRANCE TO THE PASSENGER LOADING ZONE AND FROM THE PASSENGER LOADING ZONE TO A VEHICULAR EXIT SHALL PROVIDE A VERTICAL CLEARANCE OF 114 INCHES MIN. ( 11B-503.5) 5. EACH PASSENGER LOADING ZONE DESIGNATED FOR PERSONS WITH DISABILITIES SHALL BE IDENTIFIED WITH A REFLECTORIZED SIGN COMPLYING WITH SECTION 11B-703.5. IT SHALL BE PERMANENTLY POSTED AND VISIBLE FROM THE PASSENGER LOADING ZONE STATING " PASSENGER LOADING ZONE ONLY"AND INCLUDE AN INTERNATIONAL SYMBOL OF ACCESSIBILITY IN WHITE ON A DARK BLUE BACKGROUND. (11B-503.6) 6. PASSENGER LOADING ZONES SHALL PROVIDE AT LEAST ONE PASSENGER LOADING ZONE COMPLYING WITH SECTION 11B-503 IN EVERY CONTINUOUS 100 LINEAR FEET OF LOADING ZONE SPACE OR FRACTION THEREOF. ( 11B-209.2.1) WALKING SURFACES 1. THE RUNNING SLOPE OF WALKING SURFACES SHALL NOT BE STEEPER THAN 1:20. THE CROSS SLOPE OF WALKING SURFACES SHALL NOT BE STEEPER THAN 1:48. EXCEPTION:THE RUNNING SLOPE OF SIDEWALKS SHALL NOT EXCEED THE GENERAL GRADE ESTABLISHED FOR THE ADJACENT STREET OR HIGHWAY. (11B-403.3) 2. FLOOR AND GROUND SURFACES SHALL BE STABLE, FIRM AND SLIP RESISTANT. CHANGES IN LEVEL SHALL COMPLY WITH SECTION 11B-303. 3. CHANGES IN LEVEL BETWEEN 1/4 INCH HIGH MAX. SHALL BE PERMITTED TO BE VERTICAL AND WITHOUT EDGE TREATMENT. CHANGES IN LEVEL BETWEEN 1/4 INCH HIGH MIN. AND 1/2 INCH HIGH MAX. SHALL BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2. CHANGES IN LEVEL GREATER THAN 1/2 INCH HIGH SHALL BE RAMPED, AND SHALL COMPLY WITH SECTION 11B-405 OR 11B-406. (11B-303.2, 11B-303.3, 11B-303.4) 4. ABRUPT CHANGES IN LEVEL EXCEEDING 4” IN A VERTICAL DIMENSION BETWEEN WALKS, SIDEWALKS OR OTHER PEDESTRIAN WAYS AND ADJACENT SURFACES OR FEATURES SHALL BE IDENTIFIED BY WARNING CURBS AT 6 INCHES IN HEIGHT ABOVE THE WALK OR SIDEWALK SURFACE. (11B-303.5) 5. EXCEPT AS PROVIDED IN SECTIONS 11B-403.5.2 AND 11B-403.5.3, THE CLEAR WIDTH OF WALKING SURFACES SHALL BE 36 INCHES MIN. EXCEPTIONS: A) THE CLEAR WIDTH SHALL BE REDUCED TO 32 INCHES MIN. FOR A LENGTH OF 24 INCHES MAX. PROVIDED THAT REDUCED WIDTH SEGMENTS ARE SEPARATED BY SEGMENTS THAT ARE 48 INCHES LONG MIN AND 36 INCHES WIDE MIN. B) THE CLEAR WIDTH FOR WALKING SURFACES IN CORRIDORS SERVING AN OCCUPANT LOAD OF 10 OR MORE SHALL BE 44 INCHES MIN. C) THE CLEAR WIDTH FOR SIDEWALKS AND WALKS SHALL BE 48 INCHES MIN. D) THE CLEAR WIDTH FOR AISLES SHALL BE 36 INCHES MIN IF SERVING ELEMENTS ON ONLY ONE SIDE AND 44 INCHES MIN. IF SERVING ELEMENTS ON BOTH SIDES. 6. AN ACCESSIBLE ROUTE WITH A CLEAR WIDTH LESS THAN 60 INCHES SHALL PROVIDE PASSING SPACES AT INTERVALS OF 200 FEET MAX. PASSING SPACES SHALL BE EITHER: A SPACE 60 INCHES MIN. BY 60 INCHES MIN. OR, AN INTERSECTION OF TWO WALKING SURFACES PROVIDING A T-SHAPED SPACE WHERE THE BASE AND ARMS OF THE T-SHAPED SPACE EXTEND 48 INCHES MIN. BEYOND THE INTERSECTION. (11B-403.5.3) 7. ALL WALKS WITH CONTINUOUS GRADIENTS SHALL HAVE RESTING AREAS 60 INCHES IN LENGTH, AT INTERVALS OF 400 FEET MAX. THE REST SHALL BE AT LEAST AS WIDE AS THE WALK. THE SLOPE OF THE RESTING AREA IN ALL DIRECTIONS SHALL BE 1:48 MAX. (11B-403.7) 8. OPENINGS IN FLOOR OR GROUND SURFACES SHALL NOT ALLOW PASSAGE OF A SPHERE MORE THAN 1/2 INCH DIAMETER. ELONGATED OPENING SHALL BE PLACED SO THAT THE LONG DIMENSION IS PERPENDICULAR TO THE DOMINANT DIRECTION OF TRAVEL. (11B-302.3) 9. CARPET OR CARPET TILE SHALL BE SECURELY ATTACHED AND SHALL HAVE A FIRM CUSHION, PAD, OR BACKING OR NO CUSHION OR PAD. CARPET OR CARPET TILE SHALL HAVE A LEVEL LOOP, TEXTURED LOOP, LEVEL CUT PILE, LEVEL CUT/UNCUT PILE TEXTURE. PILE HEIGHT SHALL BE 1/2 INCH MAX. EXPOSED EDGES OF CARPET SHALL BE FASTENED TO FLOOR SURFACES AND SHALL HAVE TRIM ON THE ENTIRE LENGTH OF THE EXPOSED EDGE. (11B-302.2) CURB RAMPS CURB RAMP IS DEFINED AS “A SLOPING PEDESTRIAN WAY, INTENDED FOR PEDESTRIAN TRAFFIC, WHICH PROVIDES ACCESS BETWEEN A WALK OR SIDEWALK AND A SURFACE LOCATED ABOVE OR BELOW AN ADJACENT CURB FACE”. (202) 1. CURB RAMPS MAY BE PERPENDICULAR, PARALLEL, OR A COMBINATION OF PERPENDICULAR AND PARALLEL. RAMP SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1"12. WHERE PROVIDED, CURB RAMP FLARES SHALL NOT BE STEEPER THAN 1:10. (11B-406.1, 11B-406.2) 3. THE RUNNING SLOPE OF PARALLEL CURB RAMP SEGMENTS SHALL BE IN-LINE WITH THE DIRECTION OF THE SIDEWALK TRAVEL. RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12. A TURNING SPACE 48 INCHES MIN. SHALL BE PROVIDED AT THE BOTTOM OF THE CURB RAMP. THE SLOPE OF THE TURNING SPACE IN ALL DIRECTIONS SHALL BE 1:48 MAX.( 11B-406.3) 4. BLENDED TRANSITIONS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:20.(11B-406.4) 5. CURB RAMPS AND THE FLARES SIDES SHALL BE LOCATED SO THAT THEY DO NOT PROJECT INTO THE VEHICULAR TRAFFIC LANES, PARKING SPACES, OR PARKING ACCESS AISLES. CURB RAMPS AT MARKED CROSSINGS SHALL BE WHOLLY CONTAINED WITHIN THE MARKINGS, EXCLUDING ANY FLARED SIDES. (11B-406.5.1) 6. THE CLEAR WIDTH OF CURB RAMP RUNS ( EXCLUDING ANY FLARED SIDES), BLENDED TRANSITIONS, AND TURNING SPACES SHALL BE 48 INCHES MIN. LANDINGS SHALL BE PROVIDED AT THE TOPS OF CURB RAMPS AND BLENDED TRANSITIONS. THE LANDINGS CLEAR LENGTH SHALL BE 48 INCHES MIN. THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE CURB RAMP,EXCLUDING ANY FLARED SIDES OR THE BLENDED TRANSITION LEADING TO THE LANDING. THE SLOPE OF THE LANDING IN ALL DIRECTIONS SHALL BE 1:48 MAX. ( 11B-406.5.2, 11B-406.5.3) 7.COUNTER SLOPES OF ADJOINING GUTTERS AND ROAD SURFACES IMMEDIATELY ADJACENT TO AND WITHIN 24 INCHES OF THE RAMP SHALL NOT BE STEEPER THAN 1:20. THE ADJACENT SURFACES AT TRANSITIONS AT CURB RAMPS TO WALKS, GUTTERS, AND STREETS SHALL BE AT THE SAME LEVEL. (11B-406.5.8) 8. THE BOTTOM OF DIAGONAL CURB RAMPS SHALL HAVE A CLEAR SPACE 48INCHES MIN. OUTSIDE ACTIVE TRAFFIC LANES OF THE ROADWAY. DIAGONAL OR CORNER TYPE CURB RAMPS WITH RETURNED CURBS OR OTHER WELL-DEFINED EDGES SHALL HAVE THE EDGES PARALLEL TO THE DIRECTION OF PEDESTRIAN FLOW. DIAGONAL CURB RAMPS WITH FLARED SIDES SHALL HAVE A SEGMENT OF CURB 24 INCHES LONG MIN. LOCATED ON EACH SIDE OF THE CURB RAMP AND WITHIN THE MARKED CROSSING. (11B-406.5.9, 11B-406.5.10) 9. CURB RAMPS SHALL HAVE A GROOVED BORDER 12 INCHES WIDE ALONG THE TOP OF THE CURB RAMP AT THE LEVEL SURFACE OF THE TOP OF LANDING AND AT THE OUTSIDE EDGES OF THE FLARED SIDES. AT PARALLEL CURB RAMPS, THE GROOVED BORDER SHALL BE ON THE UPPER APPROACH IMMEDIATELY ADJACENT TO THE CURB RAMP ACROSS THE FULL WIDTH. (11B-406.5.11) 10. DETECTABLE WARNINGS AT CURB RAMPS SHALL EXTEND 36 INCHES IN THE DIRECTION OF TRAVEL. DETECTABLE WARNINGS SHALL EXTEND THE FULL WIDTH OF THE RAMP RUN EXCLUDING FLARED SIDES. DETECTIBLE WARNINGS SHALL BE LOCATED SO THAT THE EDGE NEAREST THE CURB IS 6 INCHES MIN. AND 8 INCHES MAX. FROM THE LINE AT THE FACE OF THE CURB MARKING THE TRANSITION BETWEEN THE CURB AND THE GUTTER, STREET OR HIGHWAY.(11B-705.1.2.2) 11. DETECTABLE WARNINGS SHALL CONSIST OF A SURFACE OF TRUNCATED DOMES. TRUNCATED DOMES IN A DETECTABLE WARNING SURFACE SHALL HAVE A BASE DIAMETER OF 0.9 INCH MIN AND 0.92 INCH MAX, A TOP DIAMETER OF 0.45 INCH MIN AND 0.47 INCH MAX. AND A HEIGHT OF 0.18 INCH MIN AND 0.22 INCH MAX. (11B-705.1.1.1) TRUNCATED DOMES SHALL HAVE A CENTER TO CENTER SPACING OF 2.3 INCHES MIN AND 2.4 INCHES MAX., AND A BASE TO BASE SPACING OF 0.65 INCH MIN., MEASURED BETWEEN THE MOST ADJACENT DOMES ON A SQUARE GRID. (11B-705.1.1.2) DETECTABLE WARNING SURFACES SHALL CONTRAST VISUALLY WITH ADJACENT WALKING SURFACES EITHER LIGHT-ON DARK, OR DARK-ON-LIGHT.(11B-705.1.1.3) DETECTABLE WARNING SURFACES SHALL DIFFER FROM ADJOINING SURFACES IN RESILIENCY OR SOUND ON CANE CONTACT.(11B-705.1.1.4) DETECTABLE WARNING SURFACES SHALL BE YELLOW CONFORMING TO FS 33538 OF FEDERAL STANDARD 595C.(11B-705.1.1.5) EXCEPTION:DETECTABLE WARNING SURFACES AT CURB RAMPS, ISLANDS OR CUT-THROUGH MEDIANS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-705.1.1.5. RAMPS (EXTERIOR OR INTERIOR) 1. RAMPS ON ACCESSIBLE ROUTES SHALL COMPLY WITH SECTION 11B-405.RAMPS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12. CROSS SLOPES OF RAMP RUNS SHALL NOT BE STEEPER THAN 1:48. (11B-405.2, 11B-405.3) 2. FLOOR OR GROUND SURFACES OF RAMP RUNS SHALL BE STABLE, FIRM, AND SLIP RESISTANT AND SHALL COMPLY WITH SECTION 11B-302. CHANGES IN LEVEL OTHER THAN THE RUNNING SLOPE AND CROSS SLOPE ARE NOT PERMITTED ON RAMP RUNS.(11B-405.4) 3. THE CLEAR WIDTH OF THE RAMP RUN SHALL BE 48 INCHES MIN. EXCEPTIONS: A) WITHIN EMPLOYEE WORK AREAS, THE REQUIRED CLEAR WIDTH OF RAMPS THAT ARE A PART OF THE COMMON USE CIRCULATION PATHS SHALL BE PERMITTED TO BE DECREASED BY WORK AREA EQUIPMENT PROVIDED THAT THE DECREASE IS ESSENTIAL TO THE FUNCTION OF THE WORK BEING PERFORMED. B) HANDRAILS MAY PROJECT INTO THE REQUIRED CLEAR WIDTH OF THE RAMP AT EACH SIDE 3 1/2 INCHES MAX. AT THE HAND RAIL HEIGHT. C) THE CLEAR WIDTH OF RAMPS IN RESIDENTIAL USES SERVING AN OCCUPANT LOAD OF FIFTY OR LESS SHALL BE 36 INCHES MIN BETWEEN HANDRAILS. 4. THE RISE FOR ANY RAMP RUN SHALL BE 30 INCHES MAX.(11B-405.6) 5. RAMPS SHALL HAVE LANDINGS AT THE TOP AND THE BOTTOM OF EACH RAMP RUN. LANDINGS SHALL COMPLY WITH SECTION 11B-302. CHANGES IN LEVEL ARE NOT PERMITTED. EXCEPTION:SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED. (11B-405.7.1) THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE WIDEST RAMP RUN LEADING TO THE LANDING. TOP LANDING SHALL BE 60 INCHES WIDE MIN. THE LANDING CLEAR LENGTH SHALL BE 60 INCHES LONG MIN. BOTTOM LANDINGS SHALL EXTEND 72 INCHES MIN IN THE DIRECTION OF THE RAMP RUN.( 11B-405.7.2, 11B-405.7.3) 6. RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT LANDINGS SHALL HAVE A CLEAR LANDING 60 INCHES MIN BY 72 INCHES MIN IN THE DIRECTION OF DOWNWARD TRAVEL FROM THE UPPER RAMP RUN.(11B-405.7.4) 7. WHERE DOORWAYS ARE LOCATED ADJACENT TO A RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY SECTIONS 11B-404.2.2 AND 11B-404.3.2 SHALL BE PERMITTED TO OVERLAP THE REQUIRED LANDING AREA. DOORS WHEN FULLY OPEN, SHALL NOT REDUCE THE REQUIRED RAMP LANDING WIDTH BY MORE THAN 3 INCHES. DOORS , IN ANY POSITION, SHALL NOT REDUCE THE MIN. DIMENSION OF THE RAMP LANDING TO LESS THAN 42 INCHES. ( 11B-405.7.5) 8. RAMP RUNS SHALL HAVE HANDRAILS COMPLYING WITH SECTION 11B-505. ( 11B-405.8) EXCEPTIONS: A) HANDRAILS ARE NOT REQUIRED AT RAMPS IMMEDIATELY ADJACENT TO FIXED SEATING IN ASSEMBLY AREAS. B) CURB RAMPS DO NOT REQUIRE HANDRAILS. C) AT DOOR LANDINGS, HANDRAILS ARE NOT REQUIRED ON RAMP RUNS LESS THAN 6 INCHES IN RISE OR 72 INCHES IN LENGTH. 9. EDGE PROTECTION SHALL BE PROVIDED ON EACH SIDE OF RAMP RUNS AND AT EACH SIDE OF RAMP LANDINGS. (11B-405.9)EXCEPTIONS: A) EDGE PROTECTION SHALL NOT BE REQUIRED ON RAMPS THAT ARE NOT REQUIRED TO HAVE HANDRAILS AND HAVE SIDES COMPLYING WITH 11B-406.2.2. B) EDGE PROTECTION SHALL NOT BE REQUIRED ON THE SIDES OF RAMP LANDINGS SERVING AN ADJOINING RAMP RUN OR STAIRWAY. C) EDGE PROTECTION SHALL NOT BE REQUIRED ON THE SIDES OF RAMP LANDINGS HAVING A VERTICAL DROP-OFF OF 1/2 INCH MAX. WITHIN 10 INCHES HORIZONTALLY OF THE MIN. LANDING AREA SPECIFIED IN SECTION 11B-405.7. 10. A CURB, 2 INCHES HIGH MIN., OR BARRIER SHALL BE PROVIDED THAT PREVENTS THE PASSAGE OF A 4 INCH DIAMETER SPHERE, WHERE ANY PORTION OF THE SPHERE IS WITHIN 4 INCHES OF THE FINISH FLOOR OR GROUND SURFACE. TO PREVENT WHEEL ENTRAPMENT, THE CURB OR BARRIER SHALL PROVIDE A CONTINUOUS AND UNINTERRUPTED BARRIER ALONG THE LENGTH OF THE RAMP.(11B-405.9.2) 11. LANDINGS SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO PREVENT THE ACCUMULATION OF WATER. ( 11B-405.10) ENTRANCES & EXITS EXIT AS DEFINED IS "THAT PORTION OF A MEANS OF EGRESS SYSTEM BETWEEN THE EXIT ACCESS AND THE EXIT DISCHARGE OR PUBLIC WAY. EXIT COMPONENTS INCLUDE EXTERIOR EXIT DOORS AT THE LEVEL OF EXIT DISCHARGE, INTERIOR EXIT STAIRWAYS, INTERIOR EXIT RAMPS, EXIT PASSAGEWAYS, EXTERIOR EXIT STAIRWAYS AND EXTERIOR EXIT RAMPS AND HORIZONTAL EXITS." (202) EXIT ACCESS AS DEFINED IS "THAT PORTION OF A MEANS OF EGRESS SYSTEM THAT LEADS FROM ANY OCCUPIED PORTION OF A BUILDING OR STRUCTURE TO AN EXIT." (202) EXIT DISCHARGE AS DEFINED IS "THAT PORTION OF A MEANS OF EGRESS SYSTEM BETWEEN THE TERMINATION OF AN EXIT AND A PUBLIC WAY." (202) PUBLIC WAY AS DEFINED IS "A STREET, ALLEY OR OTHER PARCEL OF LAND OPEN TO THE OUTSIDE AIR LEADING TO A STREET, THAT HAS BEEN DEEDED, DEDICATED OR OTHERWISE PERMANENTLY APPROPRIATED TO THE PUBLIC FOR PUBLIC USE AND WHICH HAS A CLEAR WIDTH AND HEIGHT OF NOT LESS THAN 10 FEET.” (202) 1. ALL ENTRANCES AND EXTERIOR GROUND FLOOR EXITS TO BUILDINGS AND FACILITIES SHALL COMPLY WITH SECTION 11B-404. (11B -206.4.1) EXCEPTIONS: A) EXTERIOR GROUND FLOOR EXITS SERVING SMOKE-PROOF ENCLOSURES, STAIRWELLS, AND EXIT DOORS SERVING STAIRS ONLY SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-404. B) EXITS IN EXCESS OF THOSE REQUIRED BY CHAPTER 10, AND WHICH ARE MORE THAN 24 INCHES ABOVE GRADE SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-404.SUCH DOOR SHALL HAVE WARNING SIGNS COMPLYING WITH SECTION 11B-703.5, STATING THAT THEY ARE NOT ACCESSIBLE. 2. AN ALTERATION THAT DECREASES OR HAS THE EFFECT OF DECREASING THE ACCESSIBILITY OF A BUILDING OR FACILITIES BELOW THE REQUIREMENTS FOR NEW CONSTRUCTION AT THE TIME OF ALTERATION IS PROHIBITED. ( 11B-202.3.1) 3. WHEN ALTERATIONS OR ADDITIONS ARE MADE TO EXISTING BUILDINGS OR FACILITIES, AN ACCESSIBLE PATH OF TRAVEL TO THE SPECIFIC AREA OF ALTERATION OR ADDITION SHALL BE PROVIDED. (11B-202.4) 4. SIGNS REQUIRED BY CHAPTER 10 SECTION 1011.4 AT DOORS TO EXIT PASSAGEWAYS, EXIT DISCHARGE AND EXIT STAIRWAYS SHALL COMPLY WITH SECTION 11B-703.1, 11B-703.2, 11B-703.3 AND 11B-703.5. (11B-216.4.1) 5. SIGNS REQUIRED BY CHAPTER 10 SECTION 1007.10 TO PROVIDE DIRECTIONS TO ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH SECTION 11B-703.5. (11B-216.4.3) 6. SIGNS REQUIRED BY CHAPTER 10, SECTION 1008.9.7, ITEM 5.1 AT DOORS WITH DELAYED EGRESS LOCKS SHALL COMPLY WITH SECTIONS 11B-703.1, 11B-703.2, 11B-703.3 AND 11B-703.5. (11B-216.4.4) DOORS 1. DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES MIN. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP WITH THE DOOR OPEN 90 DEGREES. THERE SHALL BE NO PROJECTIONS INTO THE REQUIRED CLEAR OPENING WIDTH LOWER THAN 34 INCHES ABOVE THE FINISH FLOOR OR GROUND. PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES AND 80 INCHES ABOVE THE FINISH FLOOR OR GROUND SHALL NOT EXCEED 4 INCHES. (11B-404.2.3) 2. AT LEAST ONE OF THE ACTIVE LEAVES OF DOORWAYS WITH TWO LEAVES SHALL COMPLY WITH SECTION 11B-404.2.3 AND 11B-404.2.4. (11B-404.2.2) 3. MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL COMPLY WITH SECTION 11B-404.2.4. MANEUVERING CLEARANCES SHALL EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED LATCH SIDE OR HINGE SIDE CLEARANCE. (11VB-404.2.4) 4. SWINGING DOORS AND GATES SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 11B-404.2.4.1. & FIGURES 11B-404.2.4.1. (11B-404.2.4.1) 5. FLOOR OR GROUND SURFACE WITHIN REQUIRED MANEUVERING CLEARANCES SHALL COMPLY WITH SECTION 11B-302. CHANGES IN LEVEL ARE NOT PERMITTED. EXCEPTION:SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED. 6. THRESHOLDS, IF PROVIDED AT DOORWAYS SHALL BE 1/2 INCH HIGH MAX. RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH SECTION 11B-302 AND 11B-303. (11B-404.2.5) 7. THE DISTANCE BETWEEN TWO HINGED OR PIVOTED DOORS IN SERIES AND GATES IN SERIES SHALL BE 48 INCHES MIN. PLUS THE WIDTH OF DOORS OR GATES SWINGING INTO THE SPACE. (11B-404.2.6) 8. HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERABLE PARTS ON DOORS AND GATES SHALL COMPLY WITH SECTION 11B-309.4 OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 INCHES MIN AND 44 INCHES MAX. ABOVE THE FINISH FLOOR OR GROUND. WHERE SLIDING DOORS ARE IN FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. (11B-404.2.7) 9. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE OTHER THAN FIRE DOORS SHALL BE 5 POUNDS MAX. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY NOT TO EXCEED 15 POUNDS. THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR OR GATE IN A CLOSED POSITION. (11B-404.2.9) 10. THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. (1008.1.9.5) 11. DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS. (11B-404.2.8.1). DOOR AND GATE SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70 DEGREES, THE DOOR OR GATE SHALL MOVE TO THE CLOSED POSITION IN 1.5 SECONDS MIN. (11B-404.2.8.2) 12. POWERED DOORS SHALL BE FULLY AUTOMATIC DOORS COMPLYING WITH BUILDERS HARDWARE MANUFACTURER'S ASSOCIATION (BHMA) A156.10 OR LOW ENERGY OPERATED DOORS COMPLYING WITH BHMA A156.19. POWERED DOORS SERVING A BUILDING OR FACILITY WITH AN OCCUPANCY OF 150 OR MORE SHALL BE PROVIDED WITH A BACK-UP BATTERY OR BACK-UP GENERATOR. THE BACK-UP POWER SOURCE SHALL BE ABLE TO CYCLE THE DOOR A MIN. OF 100 CYCLES. POWERED DOORS SHALL BE CONTROLLED ON BOTH THE INTERIOR AND EXTERIOR SIDES OF THE DOORS BY SENSING DEVICES, PUSH PLATES, VERTICAL ACTUATION BARS OR SIMILAR OPERATING DEVICES. AT EACH LOCATION WHERE PUSH PLATES ARE PROVIDED THERE SHALL BE TWO PUSH PLATES; THE CENTER LINE OF ONE PUSH PLATE SHALL BE 7 INCHES MIN. AND 8 INCHES MAX. ABOVE THE FINISH FLOOR AND THE CENTERLINE OF THE SECOND PUSH PLATE SHALL BE 30 INCHES MIN AND 44 INCHES MAX. ABOVE THE FINISH FLOOR. EACH PUSH PLATE SHALL BE A MIN. OF 4 INCHES IN DIAMETER OR SQUARE AND SHALL DISPLAY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7. SIGNAGE IDENTIFYING THE ACCESSIBLE ENTRANCE REQUIRED BY SECTION 11B-216.6 SHALL BE PLACED ON OR IMMEDIATELY ADJACENT TO EACH POWERED DOOR. (11B-404.2.9) 13. SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES OF THE FINISH FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. (11B-404.2.10) EXCEPTIONS: A) SLIDING DOORS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-404.2.10 B) TEMPERED GLASS DOORS WITHOUT STILES AND HAVING A BOTTOM RAIL OR SHOE WITH THE TOP LEADING EDGE TAPERED AT 60 DEGREES MIN. FROM THE HORIZONTAL SHALL NOT BE REQUIRED TO MEET THE 10 INCH BOTTOM SMOOTH SURFACE HEIGHT REQUIREMENT. 14. DOORS GATES AND SIDE LIGHTS ADJACENT TO DOORS OR GATES CONTAINING ONE OR MORE GLAZING PANELS THAT PERMIT VIEWING THROUGH THE PANELS SHALL HAVE THE BOTTOM OF AT LEAST ONE GLAZED PANEL LOCATED 43 INCHES MAX, ABOVE THE FINISH FLOOR. (11B-404.2.11) EXCEPTION: GLAZING PANELS WITH THE LOWEST PART MORE THAN 66 INCHES FROM THE FINISH FLOOR OR GROUND SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-404.2.11 STAIRWAYS 1. ALL STEPS ON A FLIGHT OF STAIRS SHALL HAVE UNIFORM RISER HEIGHTS AND UNIFORM TREAD DEPTHS. RISERS SHALL BE 4 INCHES HIGH MIN. AND 7 INCHES HIGH MAX.. TREADS SHALL BE 11 INCHES DEEP MIN. (11B-504.2) 2. OPEN RISERS ARE NOT PERMITTED. (11B-504.3) EXCEPTIONS: A) ON EXTERIOR STAIRWAYS AN OPENING OF NOT MORE THAN 1/2 INCH MAY BE PERMITTED BETWEEN THE BASE OF THE RISER AND THE TREAD. B) ON EXTERIOR STAIRWAYS, RISERS CONSTRUCTED OF GRATING CONTAINING OPENINGS OF NOT MORE THE 1/2 INCH MAY BE PERMITTED. 3. INTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND LOWER TREAD MARKED BY A STRIPE PROVIDING CLEAR VISUAL CONTRAST. EXTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND ALL TREADS MARKED BY A STRIPE OF VISUAL CONTRAST. THE STRIPE SHALL BE A MIN OF 2 INCHES WIDE TO A MAX. OF 4 INCHES WIDE PLACED PARALLEL TO AND NOT MORE THAN 1 INCH FROM THE NOSE OF THE STEP OR APPROACH. A PAINTED STRIPE SHALL BE ACCEPTABLE . GROOVES SHALL NOT BE USED TO SATISFY THIS REQUIREMENT. (11B-504..4.1) 4. THE RADIUS OF THE CURVATURE AT THE LEADING EDGE OF THE TREAD SHALL BE 1/2 INCH MAX. RISERS SHALL BE PERMITTED TO SLOPE UNDER THE TREAD AT AN ANGLE OF 30 DEGREES MAX. FROM VERTICAL. THE PERMITTED PROJECTION OF THE NOSING SHALL EXTEND 1 1/4 INCHES MAX. OVER THE TREAD BELOW. (11B-504.5) 5. HANDRAILS SHALL BE PROVIDED ON BOTH SIDES OF STAIRS AND RAMPS. HANDRAILS SHALL BE CONTINUOUS WITHIN THE FULL LENGTH OF EACH STAIR FLIGHT OR RAMP RUN. INSIDE HANDRAILS ON SWITCHBACK OR DOGLEG STAIRS AND RAMPS SHALL BE CONTINUOUS BETWEEN FLIGHTS OR RUNS. (11B-505.2, 11B-505.3) 6. TOP OF GRIPPING SURFACES OF HANDRAILS SHALL BE 34 INCHES MIN. AND 38 INCHES MAX. VERTICALLY ABOVE WALKING SURFACES, STAIR NOSINGS, AND RAMP SURFACES. HANDRAILS SHALL BE AT A CONSISTENT HEIGHT ABOVE WALKING SURFACES, STAIR NOSINGS AND RAMP SURFACES. (11B-505.4) 7. CLEARANCE BETWEEN HANDRAIL GRIPPING SURFACES AND ADJACENT SURFACES SHALL BE 1 1/2 INCHES MIN. HANDRAILS MAY BE LOCATED IN A RECESS IF THE RECESS IS 3 INCHES MAX. DEEP AND 18 INCHES MIN. CLEAR ABOVE THE TOP OF THE HANDRAIL. (11B-505.5) 8. HANDRAIL GRIPPING SURFACES SHALL BE CONTINUOUS ALONG THEIR LENGTH AND SHALL NOT BE OBSTRUCTED ALONG THEIR TOPS OR SIDES. THE BOTTOMS OF HANDRAIL GRIPPING SURFACES SHALL NOT BE OBSTRUCTED FOR MORE THAN 20 PERCENT OF THEIR LENGTH. WHERE PROVIDED HORIZONTAL PROJECTIONS SHALL OCCUR 1 1/2 INCHES MIN. BELOW THE BOTTOM OF THE HANDRAILS GRIPPING SURFACE. (11B-505.6) 9. HANDRAIL GRIPPING SURFACES WITH CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF 1 1/4 INCHES MIN AND 2 INCHES MAX. HAND RAIL GRIPPING SURFACES WITH A NON-CIRCULAR CROSS SECTION SHALL HAVE A PERIMETER DIMENSION OF 4 INCHES MIN. AND 6 1/4 INCHES MAX. AND A CROSS-SECTION DIMENSION OF 2 1/4 INCHES MAX. (11B-505.7) 10. HAND RAIL GRIPPING SURFACES AND ANY SURFACES ADJACENT TO THEM SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS AND SHALL HAVE ROUNDED EDGES. (11B-505.8) 11. HANDRAILS SHALL NOT ROTATE WITHIN THEIR FITTINGS. (11B-505.9) 12. HANDRAIL GRIPPING SURFACES SHALL EXTEND BEYOND AND IN THE SAME DIRECTION OF STAIR FLIGHTS AND RAMP RUNS IN ACCORDANCE WITH SECTION 11B-505.10. (FIGURES 11B-505.10.1 & 11B-505.10.2) C-33483 Date Description Project Name Project Number Description ARCHITECT: SECONEA 12440 Firestone Blvd. Suite 1017 Norwalk, CA 90650 T: 714.321.9545 www.seconea.com Info@seconea.com LEGAL NOTES: THE DRAWINGS AND SPECIFICATIONS, IDEAS, AND DESIGNS ARE AND SHALL REMAIN THE PROPERTY OF SECONEA, INC. NO PART THEREOF SHALL BE COPIED OR USED WITH ANY OTHER WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT THE WRITTEN CONSENT OF SECONEA, INC. SECONEA, INC. WAIVES ANY AND ALL RESPONSIBILITY AND LIABILITY FOR PROBLEMS WITCH ARISE FROM FAILURE TO FOLLOW THESE PLANS, SPECIFICATIONS, AND DESIGN INTENT THEY CONVEY, OR FOR PROBLEMS WHICH ARISE FROM OTHERS' FAILURE TO OBTAIN AND/OR FOLLOW THE DESIGN PROFESSIONAL'S GUIDANCE WITH RESPECT TO ANY ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR CONFLICTS WHICH ARE ALLEGED. ©2023 SECONEA 6-30-2025 A0.32 ACCESSIBILITY NOTES 23_A12 LIFE 4 CUTS - TENANT IMPROVEMENTS LIFE 4 CUTS 400 S BALDWIN AVE. SUITE #T30, ARCADIA, CA 91007 07/21/2023 PLAN CHECK SET #1 SPACE ALLOWANCE & REACH RANGES 1. FLOOR OR GROUND SURFACES OF A CLEAR FLOOR OR GROUND SPACE SHALL COMPLY WITH SECTION 11B-302. CHANGES IN LEVEL ARE NOT PERMITTED. (11B-305.2) EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED. 2. THE CLEAR FLOOR OR GROUND SPACE SHALL BE 30 INCHES MIN. BY 48 INCHES MIN. (11B-305.3). 3. UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR GROUND SPACE SHALL BE POSITIONED FOR EITHER FORWARD OR PARALLEL APPROACH TO AN ELEMENT. (11B-305.5) 4. ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND SPACE SHALL ADJOIN AN ACCESSIBLE ROUTE OR ADJOIN ANOTHER CLEAR FLOOR OR GROUND SPACE. (11B-305.6) 5. TURNING SPACE SHALL COMPLY WITH SECTION 11B-304.3.1 CIRCULAR SPACE OR 11B-304.3.2 T-SHAPED SPACE. 6. REACH RANGES SHALL COMPLY WITH SECTION 11B-308. 7. WHERE A FORWARD REACH IS UNOBSTRUCTED, THE HIGH FORWARD REACH SHALL BE 48 INCHES MAX. AND THE LOW FORWARD REACH SHALL BE 15 INCHES MIN. ABOVE THE FINISH FLOOR OR GROUND. (11B-308.2.1) 8. WHERE A CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE SIDE REACH IS UNOBSTRUCTED, THE HIGH SIDE REACH SHALL BE 48 INCHES MAX. AND THE LOW SIDE REACH SHALL BE 15 INCHES MIN. ABOVE THE FINISH FLOOR OR GROUND. 9. WHERE SPACE BENEATH AN ELEMENT IS INCLUDED AS PART OF CLEAR FLOOR OR GROUND SPACE OR TURNING SPACE, THE SPACE SHALL COMPLY WITH SECTION 11B-306. ADDITIONAL SPACE SHALL NOT BE PROHIBITED BENEATH AN ELEMENT BUT SHALL NOT BE CONSIDERED AS PART OF THE CLEAR FLOOR OR GROUND SPACE OR TURNING SPACE. (11B-306.1) 10. TOE CLEARANCE. SPACE UNDER AN ELEMENT BETWEEN THE FINISH FLOOR OR GROUND AND 9 INCHES ABOVE THE FINISH FLOOR OR GROUND SHALL BE CONSIDERED TOE CLEARANCE AND SHALL COMPLY WITH SECTION 11B-306.2. 11. TOE CLEARANCE SHALL BE 30 INCHES WIDE MIN. (11B-306.2.5) 12. KNEE CLEARANCE. SPACE UNDER AN ELEMENT BETWEEN 9 INCHES AND 27 INCHES ABOVE THE FINISH FLOOR OR GROUND SHALL BE CONSIDERED KNEE CLEARANCE AND SHALL COMPLY WITH SECTION 11B-306.3. 13. KNEE CLEARANCE SHALL BE 30 INCHES WIDE MIN. (11B-306.3.5) PROTRUDING OBJECTS 1. OBJECTS WITH LEADING EDGES BETWEEN 27 INCHES AND NOT MORE THAN 80 INCHES ABOVE THE FINISHED FLOOR OR GROUND SHALL PROTRUDE 4 INCHES MAX. HORIZONTALLY INTO THE CIRCULATION PATH. (11B-307.2) EXCEPTION:HANDRAILS SHALL BE PERMITTED TO PROTRUDE 4 1/2 INCHES MAX. 2. FREE-STANDING OBJECTS MOUNTED ON POSTS OR PYLONS SHALL OVERHANG CIRCULATION PATHS 12INCHES MAXIMUM WHEN LOCATED 27 INCHES MIN. AND 80 INCHES MAX. ABOVE THE FINISH FLOOR OR GROUND. WHERE A SIGN OR OTHER OBSTRUCTION IS MOUNTED BETWEEN POSTS OR PYLONS AND THE CLEAR DISTANCE BETWEEN THE POSTS OR PYLON IS GREATER THAN 12 INCHES, THE LOWEST EDGE OF SUCH SIGN OR OBSTRUCTION SHALL BE 27 INCHES MAX. AND 80 INCHES MIN. ABOVE THE FINISH FLOOR OR GROUND. (11B-307.3) 3. WHERE SIGNS OR OTHER OBJECTS ARE MOUNTED ON POST OR PYLONS AND THEIR BOTTOM EDGES ARE LESS THAN 80 INCHES ABOVE THE FLOOR OR GROUND SURFACE, THE EDGES OF SUCH SINGS OR OBJECTS SHALL BE ROUNDED OR EASED AND THE CORNERS SHALL HAVE A MIN. RADIUS OF 1/8 INCH. (11B-307.3.1) 4. VERTICAL CLEARANCE SHALL BE 80 INCHES HIGH MIN. GUARDRAILS OR OTHER BARRIERS SHALL BE PROVIDED WHERE THE VERTICAL CLEARANCE IS LESS THAN 80 INCHES HIGH. THE LEADING EDGE OF SUCH GUARDRAIL OR BARRIER SHALL BE LOCATED 27 INCHES MAX. ABOVE THE FINISH FLOOR OR GROUND. (11B-307.4) EXCEPTION:DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES MIN. ABOVE THE FINISH FLOOR OF GROUND. 5. PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH OF AN ACCESSIBLE ROUTES. (11B-307.5) 6. THE MEANS OF EGRESS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN 7 FEET 6 INCHES. (1003.2) EXCEPTIONS: A) SLOPED CEILINGS IN ACCORDANCE WITH SECTION 1208.2 B) STAIR HEADROOM IN ACCORDANCE WITH SECTION 1009.5 C) RAMP HEADROOM IN ACCORDANCE WITH SECTION 1010.6.2 D) THE CLEAR HEIGHT OF FLOOR LEVELS IN VEHICULAR AND PEDESTRIAN TRAFFIC AREAS IN PARKING GARAGES IN ACCORDANCE WITH SECTION 406.4.1 E) AREAS ABOVE AND BELOW MEZZANINE FLOORS IN ACCORDANCE WITH SECTION 505.2 CONTROLS & OPERATING MECHANISMS 1. OPERABLE PARTS ON ACCESSIBLE ELEMENTS, ACCESSIBLE ROUTES AND IN ACCESSIBLE ROOMS AND SPACES SHALL COMPLY WITH SECTION 11B-309. 2. A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH SECTION 11B-305 SHALL BE PROVIDED. (11B-309.2) 3. OPERABLE PARTS SHALL BE PLACED WITHIN ONE OR MORE OF THE REACH RANGES SPECIFIED IN SECTION 11B-308.(11B-309.3) 4. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PUNCHING, OR TWISTING OF THE WRIST. TO FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAX. (11B-309.4) DRINKING FOUNTAINS 1. DRINKING FOUNTAINS SHALL COMPLY WITH SECTIONS 11B-307 AND 11B-602. 2. UNITS SHALL HAVE A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH SECTION 11B-305 POSITIONED FOR A FORWARD APPROACH AND CENTERED ON THE UNIT. KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11B-306 SHALL BE PROVIDED. (11B-602.2) 3. OPERABLE PARTS SHALL COMPLY WITH SECTION 11B-309. THE FLOW OF WATER SHALL BE ACTIVATED BY A MANUALLY OPERATED SYSTEM THAT IS FRONT MOUNTED OR SIDE MOUNTED AND LOCATED 6 INCHES OF THE FRONT EDGE OF THE FOUNTAIN OR AUTOMATIC ELECTRONICALLY CONTROLLED DEVICE. (11B-602.3) 4. SPOUT OUTLETS SHALL BE 36 INCHES MAX. AV=ABOVE THE FINISH FLOOR OR GROUND. (11B-602.4) SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 INCHES MIN. AND 43 INCHES MAX. ABOVE THE FINISH FLOOR OR GROUND. (11B-602.7) 5.WALL AND POST MOUNTED CANTILEVERED DRINKING FOUNTAINS SHALL BE 18 INCHES MIN. AND 19 INCHES MAX. IN DEPTH. (11B-602.8) 6. ALL DRINKING FOUNTAINS SHALL EITHER BE LOCATED COMPLETELY WITHIN ALCOVES, POSITIONED COMPLETELY BETWEEN WING WALLS, OR OTHERWISE POSITIONED SO AS NOT TO ENCROACH INTO PEDESTRIAN WAYS. THE PROTECTED AREA SHALL BE 32 INCHES WIDE MIN. AND 18 INCHES DEEP MIN. AND SHALL COMPLY WITH SECTION 11B-305.7. WHEN USED, WING WALLS OR BARRIERS SHALL PROJECT HORIZONTALLY AT LEAST AS FAR AS THE DRINKING FOUNTAIN AND TO WITHIN 6 INCHES VERTICALLY FROM THE FLOOR OR GROUND SURFACE. ( 11B-602.9) TOILET AND BATHING ROOMS 1. WHERE TOILET FACILITIES AND BATHING FACILITIES ARE PROVIDED, THEY SHALL COMPLY WITH SECTION 11B-213. (11B-213.1) 2. WHERE TOILET ROOMS ARE PROVIDED, EACH TOILET ROOM SHALL COMPLY WITH SECTION 11B-603. WHERE BATHING ROOMS ARE PROVIDED EACH BATHING ROOM SHALL COMPLY WITH SECTION 11B-603. (11B-213.2) 3. UNISEX TOILET ROOMS SHALL CONTAIN NOT MORE THAN ONE LAVATORY, AND NOT MORE THAN TWO WATER CLOSETS WITHOUT URINALS OR ONE WATER CLOSET AND ONE URINAL. UNISEX BATHING ROOMS SHALL CONTAIN ONE SHOWER OR ONE SHOWER AND ONE BATHTUB, ONE LAVATORY AND ONE WATER CLOSET. DOORS TO UNISEX TOILET ROOMS AND UNISEX BATHING ROOMS SHALL PRIVACY LATCHES. (11B-213.2.1) 4. WHERE TOILET COMPARTMENTS ARE PROVIDED, AT LEAST ONE TOILET COMPARTMENT SHALL COMPLY WITH SECTION 11B-604.8.1.IN ADDITION AT LEAST ONE COMPARTMENT SHALL COMPLY WITH SECTION 11B-604.8.2 WHERE SIX OR MORE TOILET COMPARTMENTS ARE PROVIDED OR WHERE A COMBINATION OF URINALS AND WATER CLOSETS TOTAL SIX OR MORE FIXTURES. (11B-213.3.1) 5. WHERE LAVATORIES ARE PROVIDED, AT LEAST 5 PERCENT BUT NO FEWER THAN ONE SHALL COMPLY WITH SECTION 11B-606 AND SHALL NOT BE LOCATED IN A TOILET COMPARTMENT. (11B-213.3.4) 6. WHERE BATHTUBS OR SHOWERS ARE PROVIDED, AT LEAST ONE BATHTUB COMPLYING WITH SECTION 11B-607 OR AT LEAST ONE SHOWER COMPLYING WITH SECTION 11B-608 SHALL BE PROVIDED. (11B-213.3.6) 7. TURNING SPACE COMPLYING WITH SECTION 11B-304 (CIRCULAR SPACE AND T-SHAPED SPACE) SHALL BE PROVIDED WITHIN THE ROOM. (11B-603.2.1) 8. REQUIRED CLEAR FLOOR SPACES, CLEARANCE AT FIXTURES AND TURNING SPACE SHALL BE PERMITTED TO OVERLAP. ( 11B-603.2.2) 9. DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE. OTHER THAN THE DOOR TO THE ACCESSIBLE WATER CLOSET COMPARTMENT, A DOOR IN ANY POSITION, MAY ENCROACH INTO THE TURNING SPACE BY 12 INCHES MAX. (11B-603.2.3) 10. THE CENTERLINE OF THE WATER CLOSET SHALL BE 17 INCHES MIN. TO 18 INCHES MAX. FROM THE SIDE WALL OR PARTITION, EXCEPT THAT THE WATER CLOSET SHALL BE 17 INCHES MIN. TO 19 INCHES MAX. FROM THE SIDE WALL OR PARTITION IN THE AMBULATORY ACCESSIBLE TOILET COMPARTMENT.(11B-604.2) 11. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH SECTION 11B-309 EXCEPT THEY SHALL BE LOCATED 44 INCHES MAX. ABOVE THE FINISH FLOOR. FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET. (11B-604.6) 12. CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES MIN. MEASURED PERPENDICULAR FROM THE SIDE WALL AND 56 INCHES MIN. MEASURED PERPENDICULAR FROM THE REAR WALL. A MIN. 60 INCHES WIDE AND 48 INCHES DEEP MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF THE WATER CLOSET. (11B-604.3.1). WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL COMPLY WITH SECTION 11B-604.8.1. (11B-604.8.1) 13. THE REQUIRED CLEARANCE AROUND THE WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE WATER CLOSET, ASSOCIATED GRAB BARS, DISPENSERS, SANITARY NAPKIN DISPOSAL UNITS, COAT HOOKS, SHELVES, ACCESSIBLE ROUTES, CLEAR FLOOR SPACE AND CLEARANCES REQUIRED AT OTHER FIXTURES AND TURNING SPACE. NO OTHER FIXTURE OR OBSTRUCTIONS SHALL BE LOCATED WITHIN THE REQUIRED WATER CLOSET CLEARANCE. (11B-604.3.2) 14. TOILET COMPARTMENT DOORS, INCLUDING HARDWARE SHALL COMPLY WITH SECTION 11B-404 EXCEPT AS NOTED IN SECTION 11B-608.1.2., AND FIGURES 11B-604.8.1.1.2 ,11B-604.8.1.2 AND 11B-604.8.1.1.3. THE DOOR SHALL BE SELF- CLOSING. A DOOR PULL COMPLYING WITH SECTION 11B-404.2.7 SHALL BE PLACED ON BOTH SIDES OF THE DOOR NEAR THE LATCH. (11B-604.8.1.2) 15. AT LEAST ONE SIDE PARTITION SHALL PROVIDE A TOE CLEARANCE OF 9 INCHES MIN ABOVE THE FINISH FLOOR AND 6 INCHES DEEP MIN. BEYOND THE COMPARTMENT-SIDE FACE OF THE PARTITION, EXCLUSIVE OF PARTITION SUPPORT MEMBERS. 16. AMBULATORY ACCESSIBLE COMPARTMENTS SHALL HAVE A DEPTH OF 60 INCHES MIN. AND A WIDTH OF 35 INCHES MIN. AND 37 INCHES MAX. (11B-604.8.2.1) 17. THE AMBULATORY DOOR SHALL BE SELF-CLOSING. A DOOR PULL COMPLYING WITH SECTION 11B-404.2.7 SHALL BE PLACED ON BOTH SIDES OF THE DOOR NEAR THE LATCH. TOILET COMPARTMENT DOORS SHALL NOT SWING INTO THE MIN. REQUIRED COMPARTMENT AREA. (11B-604.8.2.2). 18. URINALS SHALL BE THE STALL-TYPE OR THE WALL-HUNG TYPE WITH THE RIM 17 INCHES MAX. ABOVE THE FINISH FLOOR OR GROUND. URINALS SHALL BE 13 1/2 INCHES DEEP MIN. MEASURED FROM THE OUTER FACE OF THE URINAL RIM TO THE BACK OF THE FIXTURE. (11B-605.2). 19. A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH SECTION 11B-305 POSITIONED FOR FORWARD APPROACH SHALL BE PROVIDED. (11B-605.3). 20. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH SECTION 11B-309 EXCEPT THAT THE FLUSH CONTROL SHALL BE MOUNTED AT A MIN. HEIGHT OF 44 INCHES ABOVE THE FINISH FLOOR. (11B-605.4). 21. LAVATORIES AND SINKS SHALL COMPLY WITH SECTION 11B-606. 22. A CLEAR FLOOR SPACE COMPLYING WITH SECTION 11B-305, POSITIONED FOR A FORWARD APPROACH AND KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11B-306 SHALL BE PROVIDED. (11B-606.2) 23. LAVATORIES AND SINK SHALL BE INSTALLED WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES MAX. ABOVE THE FINISH FLOOR OR GROUND. (11B-606.3) 24. CONTROLS FOR FAUCETS SHALL COMPLY WITH SECTION 11B-309. HAND -OPERATED METERING FAUCETS SHALL REMAIN OPEN FOR 10 SECONDS MIN. (11B-606.4) 25. WATER SUPPLY AND DRAIN PIPES UNDER LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES OR SINKS.(11B-606.5) 26. LAVATORIES, WHEN LOCATED ADJACENT TO A SIDE WALL OR PARTITION, SHALL BE A MIN. OF 18 INCHES TO THE CENTERLINE OF THE FIXTURE. (11B-606.6) SINKS SHALL BE 6 1/2 INCHES DEEP MAX. ( 11B-606.7) TOILET AND BATHING FIXTURES & ACCESSORIES 1. THE SEAT HEIGHT OF AN ACCESSIBLE WATER CLOSET ABOVE THE FINISH FLOOR SHALL BE 17 INCHES MIN. AND 19 INCHES MAX. MEASURED TO THE TOP OF THE SEAT. SEAT SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. SEAT SHALL BE 2 INCHES HIGH MAX. ( 11B-604.4) 2. GRAB BARS WITH CIRCULAR CROSS SECTIONS SHALL HAVE AN OUTSIDE DIAMETER OF 1 1/4 INCHES MIN AND 2 INCHES MAX. GRAB BARS WITH NON-CIRCULAR CROSS SECTIONS SHALL HAVE A CROSS-SECTION DIMENSION OF 2 INCHES MAX. AND A PERIMETER DIMENSION OF 4 INCHES MIN. AND 4.8 INCHES MAX. ( 11B-609.2.1 & 11B-609.2.2) 3. THE SPACING BETWEEN THE WALL AND THE GRAB BAR SHALL BE 1 1/2 INCHES MIN. THE SPACE BETWEEN THE GRAB BAR AND PROJECTING OBJECTS BELOW AND AT THE ENDS SHALL BE 1 1/2 INCHES MIN. THE SPACE BETWEEN THE GRAB BAR AND PROJECTING OBJECTS ABOVE SHALL BE 12 INCHES MIN. ( 11B-609.3) 4. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MIN AND 36 INCHES MAX. ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE.(11B-609.4) GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.(11B-609.6) ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS IS APPLIED. (11B-609.8) 5. GRAB BARS FOR WATER CLOSETS SHALL BE PROVIDED ON THE SIDE WALL CLOSEST TO THE WATER CLOSET AND ON THE REAR WALL. THE SIDE WALL GRAB BAR SHALL BE 42 INCHES LONG MIN., LOCATED 12 INCHES MAX. FROM THE REAR WALL AND EXTENDING 54 INCHES MIN. FROM THE REAR WALL WITH THE FRONT END POSITIONED 24 INCHES MIN. IN FRONT OF THE WATER CLOSET. (11B-604.5.1) THE REAR WALL GRAB BAR SHALL BE 36 INCHES LONG MIN. AND EXTEND FROM THE CENTERLINE OF THE WATER CLOSET 12 INCHES MIN. ON ONE SIDE AND 24 INCHES MIN. ON THE OTHER SIDE. (11B-604.5.2) 6. GRAB BARS FOR ROLL-IN SHOWER COMPARTMENTS SHALL COMPLY WITH SECTIONS 11B-609 AND SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 11B-608.3 7. MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 40 INCHES MAX. ABOVE THE FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES MAX. ABOVE THE FINISH FLOOR OR GROUND. (11B-603.3) 8. WHERE MIRRORS ARE PROVIDED IN LOCKER ROOMS, MIRRORS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 20 INCHES MAX. ABOVE THE FINISH FLOOR OR GROUND. MIRRORS SHALL BE FULL LENGTH WITH A REFLECTIVE SURFACE 18 INCHES WIDE MIN. BY 54 INCHES HIGH MIN. AND SHALL BE MOUNTED IN A POSITION AFFORDING A VIEW TO A PERSON ON THE BENCH AS WELL AS TO A PERSON IN A STANDING POSITION. ( 11B-803.6) 9. BENCHES SHALL COMPLY WITH SECTION 11B-903. A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH SECTION 11B-305 SHALL BE PROVIDED AND SHALL BE POSITIONED AT THE END OF THE BENCH SEAT AND PARALLEL TO THE SHORT AXIS OF THE BENCH. (11B-903.2) 11. BENCHES SHALL HAVE A SEATS THAT ARE 48 INCHES LONG MIN. AND 20 INCHES DEEP MIN AND 24 INCHES DEEP MAX. THE BENCH SHALL PROVIDE FOR BACK SUPPORT OR SHALL BE AFFIXED TO A WALL ALONG ITS LONG DIMENSION. BACK SUPPORT SHALL BE 48 INCHES LONG MIN. AND SHALL EXTEND FROM A POINT 2 INCHES MAX. ABOVE THE SEAT SURFACE TO A POINT 18 INCHES MIN. ABOVE THE SEAT SURFACE. THE TOP OF THE BENCH SEAT SURFACE SHALL BE 17 INCHES MIN. AND 19 INCHES MAX. ABOVE THE FINISH FLOOR OR GROUND. (11B-9303.3, 11B-903.4, 11B-903.5) 12. ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS IS APPLIED AT ANY POINT ON THE SEAT. (11B-903.6) 13. WHERE TOWEL OR SANITARY NAPKIN DISPENSERS, WASTE RECEPTACLES, OR OTHER ACCESSORIES ARE PROVIDED IN TOILET FACILITIES, AT LEAST ONE OF EACH TYPE SHALL BE LOCATED ON AN ACCESSIBLE ROUTE. ALL OPERABLE PARTS, INCLUDING COIN SLOTS, SHALL BE 40" MAX. ABOVE THE FINISHED FLOOR. (11B-603.5) 14. TOILET PAPER DISPENSERS SHALL COMPLY WITH SECTION 11B-309.4 AND SHALL BE 7 INCHES MIN. AND 9 INCHES MAX. IN FRONT OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE BELOW THE GRAB BAR, 19 INCHES MIN. ABOVE THE FINISH FLOOR AND SHALL NOT BE LOCATED BEHIND GRAB BARS. (11B-604.7) 15. COAT HOOKS SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES SPECIFIED IN SECTION 11B-308. SHELVES SHALL BE LOCATED 40 INCHES MIN AND 48 INCHES MAX. ABOVE THE FINISH FLOOR. (11B-604.8) SIGNS & IDENTIFICATION 1. SIGNS SHALL COMPLY WITH SECTION 11B-703. WHERE BOTH VISUAL AND TACTILE CHARACTERS ARE REQUIRED, EITHER ONE SIGN WITH BOTH VISUAL AND TACTILE CHARACTERS, OR TWO SEPARATE SIGNS, ONE WITH VISUAL AND ONE WITH TACTILE CHARACTERS SHALL BE PROVIDED. (11B-703.1) 2. RAISED CHARACTERS SHALL COMPLY WITH SECTION 11B-703.2 AND SHALL BE DUPLICATED IN BRAILLE COMPLYING WITH SECTION 11B-703.3. RAISED CHARACTERS SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 11B-703.4. A) RAISED CHARACTERS SHALL BE 1/32 INCH MIN ABOVE THEIR BACKGROUND.(11B-703.2.1) B) CHARACTERS SHALL BE UPPERCASE.(11B-703.2.2) C) CHARACTERS SHALL BE SANS SERIF. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY DECORATIVE OR OF OTHER UNUSUAL FORMS.(11B-703.2.3) D) CHARACTERS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER "O" IS 60 PERCENT MIN. AND 110 PERCENTS MAX. OF THE HEIGHT OF THE UPPERCASE LETTER"I".(11B-703.2.4) E) CHARACTERS HEIGHT MEASURED VERTICALLY FROM THE BASELINE OF THE CHARACTER SHALL BE 5/8 INCHES MIN. AND 2 INCHES MAX. BASED ON THE HEIGHT OF THE UPPERCASE LETTER "I".(11B-703.2.5) F) STROKE THICKNESS OF THE UPPERCASE LETTER "I" SHALL BE 15 PERCENT MAX. OF THE HEIGHT OF THE CHARACTER.(11B-703.2.6) G) CHARACTER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSETS POINTS OF ADJACENT RAISED CHARACTERS WITHIN A MESSAGE SHALL BE SEPARATED FROM RAISED BORDERS AND DECORATIVE ELEMENTS 3/8 INCH MIN. (11B-703.2.7) SPACING BETWEEN THE BASE LINES OD SEPARATE LINES OF RAISED CHARACTERS WITHIN A MESSAGE SHALL BE 135 PERCENT MIN. AND 170 PERCENT MAX. OF THE RAISED CHARACTER HEIGHT. (11B-703.2.8) TEXT SHALL BE IN A HORIZONTAL FORMAT. (11B-703.2.9) 3. BRAILLE SHALL BE CONTRACTED (GRADE 2) AND SHALL COMPLY WITH SECTIONS 11B-703.3 AND 11B-703.4. 4. BRAILLE DOTS SHALL HAVE A DOMED OR ROUNDED SHAPE AND SHALL COMPLY WITH TABLE 11B-703.3.1. 5. BRAILLE SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT IN A HORIZONTAL FORMAT, FLUSH LEFT OR CENTERED. BRAILLE SHALL BE SEPARATED 3/8 INCH MIN. AND 1/2 INCH MAX. FORM ANY OTHER TACTILE CHARACTERS AND 3/8 INCH MIN. FROM RAISED BORDERS OR DECORATIVE ELEMENTS. (11B-703.3.2) 6. WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONGSIDE THE DOOR AT THE LATCH SIDE. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO THE RIGHT OF THE RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE AT THE LATCH SIDE OF A SINGLE DOOR OR AT THE RIGHT SIDE OF DOUBLE DOORS, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL. SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18 INCHES MIN. BY 18 INCHES MIN., CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. (11B-703.4.2) 7. SIGNS THAT PROVIDE DIRECTION TO OR INFORMATION ABOUT INTERIOR AND EXTERIOR SPACES AND FACILITIES OF THE SITE SHALL COMPLY WITH SECTION 11B-703.5. 8. VISUAL CHARACTERS SHALL COMPLY WITH SECTION 11B-703.5. 9. CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. (11B-703.5.1) 10. MINIMUM CHARACTER HEIGHT SHALL COMPLY THE TABLE 11B-703.5.5. VISUAL CHARACTERS SHALL BE 40 INCHES MIN. ABOVE THE FINISH FLOOR. ( 11B-703.5.6) 11. PICTOGRAMS SHALL HAVE A FIELD HEIGHT OF 6 INCHES MIN.. CHARACTERS AND BRAILLE SHALL NOT BE LOCATED INTHE PICTOGRAM FIELD.(11B-703.6.1) 12. PICTOGRAMS AND THEIR FIELD SHALL HAVE A NON-GLARE FINISH. PICTOGRAMS SHALL CONTRAST WITH THEIR FIELD WITH EITHER A LIGHT PICTOGRAM ON A DARK FIELD OR A DARK PICTOGRAM ON A LIGHT FIELD. (11B-703.6.2) 13. PICTOGRAMS SHALL HAVE TEXT DESCRIPTORS LOCATED DIRECTLY BELOW THE PICTOGRAM FIELD. TEXT DESCRIPTORS SHALL COMPLY WITH SECTIONS 11B-703.2, 11B-703.3 AND 11B-703.4. (11B-703.6.3) 14. SYMBOLS OF ACCESSIBILITY AND THEIR BACKGROUNDS SHALL HAVE A NON-GLARE FINISH. SYMBOLS OF ACCESSIBILITY SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER A LIGHT SYMBOL ON A DARK FIELD OR A DARK SYMBOL ON A LIGHT FIELD. (11B-703.7.1) 15. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL COMPLY WITH FIGURES 11B-703.7.2. THE SYMBOL SHALL CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE COLOR NO. 15090 IN FEDERAL STANDARD 595B. (11B-703.7.2). 16. DOORWAYS LEADING TO TOILET ROOMS AND BATHING ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC SYMBOL COMPLYING WITH SECTION 11B-703.7.2.6. THE SYMBOL SHALL BE MOUNTED AT 58 INCHES MIN. AND 60 INCHES MAX. ABOVE THE FINISH FLOOR OR GROUND SURFACE MEASURED FORM THE CENTERLINE OF THE SYMBOL. 17. PUBLIC TTYs SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF TTY COMPLYING WITH SECTION 11B-703.7.2.2. 18. DIRECTIONAL SIGNS INDICATING THE LOCATION OF THE NEAREST PUBLIC TTY SHALL BE PROVIDED AT ALL BANKS OF PUBLIC PAY TELEPHONES NOT CONTAINING A PUBLIC TTY. (11B-216.9.2) 19. EACH ASSEMBLY AREA REQUIRED BY SECTION 1B-219 TO PROVIDE ASSITIVE LISTENING SYSTEMS SHALL PROVIDE SIGNS INFORMING PATRONS OF THE AVAILABILITYOF THE LISTENING SYSTEM. THE SIGN SHALL INCLUDE WORDING THAT STATES "ASSISTIVE-LISTENING SYSTEM AVAIABLE"AND SHALL BE POSTED IN A PROMINENT PLACE AT OR NEAR THE ASSEMBLY AREA ENTRANCE. ASSITIVE LISTENING SIGNS SHALL COMPLY WITH SECTION 11B-703.5 AND SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESS FOR THE HEARING LOSS COMPLYING WITH SECTION 11B-703.7.2.4. (11B-216.10) 20. INTERIOR AND EXTERIOR SIGNS IDENTIFYING PERMANENT ROOMS AND SPACES SHALL COMPLY WITH SECTIONS 11B-703.1, 11B-703.2, 11B-703.3 AND 11B-703.5. WHERE PICTOGRAMS ARE PROVIDED AS DESIGNATIONS OF PERMANENT ROOMS AND SPACES, THE PICTOGRAMS SHALL COMPLY WITH SECTION 11B- 703.6 AND SHALL HAVE TEXT DESCRIPTORS COMPLYING WITH SECTIONS 11B-703.2 AND 11B-703.5. ELECTRICAL 1. FIRE ALARM SYSTEMS SHALL HAVE PERMANENTLY INSTALLED AUDIBLE AND VISIBLE ALARMS COMPLYING WITH NFPA 72 AND CHAPTER 9, SECTIONS 907.5.2.1 AND 907.5.2.3. (11B-702). 2. VISIBLE ALARM NOTIFICATION APPLIANCES SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS 907.5.2.3.1 THROUGH 907.5.2.3.5. 3. VISIBLE ALARM NOTIFICATION APPLIANCES SHALL BE PROVIDED IN PUBLIC USE AREA AND COMMON USE AREAS, INCLUDING BUT NOT LIMITED TO: (907.5.2.3.1) A) SANITARY FACILITIES INCLUDING RESTROOMS, BATHROOMS AND SHOWER ROOMS B) CORRIDORS C) OCCUPIED ROOMS WHERE AMBIENT NOISE IMPAIRS HEARING OF THE FIRE ALARM D) LOBBIES E) MULTIPURPOSE ROOMS F) MEETING ROOMS G) CLASSROOMS 4. CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, OR COOLING, HEATING, AND VENTILATING EQUIPMENT SHALL COMPLY WITH SECTION 11B-308 EXCEPT THE LOW REACH SHALL BE MEASURED TO THE BOTTOM OF THE OUTLET BOX AND THE HIGH REACH SHALL BE MEASURED TO THE TOP OF THE OUTLET BOX. (11B-308.1.1) 5. ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES SHALL COMPLY WITH SECTION 11B-308 EXCEPT THE LOW REACH SHALL BE MEASURED TO THE BOTTOM OF THE OUTLET BOX AND THE HIGH REACH SHALL BE MEASURED TO THE TOP OF THE OUTLET BOX. (11B-308.1.2) C-33483 Date Description Project Name Project Number Description ARCHITECT: SECONEA 12440 Firestone Blvd. Suite 1017 Norwalk, CA 90650 T: 714.321.9545 www.seconea.com Info@seconea.com LEGAL NOTES: THE DRAWINGS AND SPECIFICATIONS, IDEAS, AND DESIGNS ARE AND SHALL REMAIN THE PROPERTY OF SECONEA, INC. NO PART THEREOF SHALL BE COPIED OR USED WITH ANY OTHER WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT THE WRITTEN CONSENT OF SECONEA, INC. SECONEA, INC. WAIVES ANY AND ALL RESPONSIBILITY AND LIABILITY FOR PROBLEMS WITCH ARISE FROM FAILURE TO FOLLOW THESE PLANS, SPECIFICATIONS, AND DESIGN INTENT THEY CONVEY, OR FOR PROBLEMS WHICH ARISE FROM OTHERS' FAILURE TO OBTAIN AND/OR FOLLOW THE DESIGN PROFESSIONAL'S GUIDANCE WITH RESPECT TO ANY ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR CONFLICTS WHICH ARE ALLEGED. ©2023 SECONEA 6-30-2025 A0.33 ACCESSIBILITY NOTES 2 23_A12 LIFE 4 CUTS - TENANT IMPROVEMENTS LIFE 4 CUTS 400 S BALDWIN AVE. SUITE #T30, ARCADIA, CA 91007 07/21/2023 PLAN CHECK SET #1 NIC (NOT IN CONTRACT) NUMBER OF OCCUPANTS EXITING COMMON PATH OF TRAVEL EXIT ACCESS TRAVEL DISTANCE EXITING LEGEND ROOM AREAROOM NAME XX SF 1/XX SF XX OCCUPANT LOAD FACTOR NUMBER OF OCCUPANTS 0 NUMBER OF OCCUPANTS DOOR WIDTH REQUIRED DOOR WIDTH PROVIDED EXIT SIGN EMERGENCY LIGHT W/ 90MIN BATTERY BACKUP XX OCCUP X" (REQ'D) DOOR XX X" (PROV) DOOR WIDTH FACTOR FIRE EXTINGUISHER FE (E) FULL-HEIGHT PARTITION WALL (E) 7'-6" HEIGHT PARTITION WALL (N) 7'-6" HEIGHT PARTITION WALL (E)DOOR 12 34 68 OCCPT (REQD) (PROV) 0.2 EX I T T R A V E L D I S T A N C E = 3 3 ' - 1 1 " FLOOR AREA PER OCCUP. CBC TABLE 1004.5 BUSINESS (150 GROSS) MERCHANTILE (60 GROSS) STORAGE (300GROSS) 12 ACCESSIBLE TACTILE EXIT SIGNAGE PER 15/A0.31 (E) 55.7 SF1 OCCUP./ 60 SF PHOTO BOOTH -2 40.0 SF 1 OCCUP. / 150 SF OFFICE 39.4 SF 1 OCCUP. / 300 SF (E) STORAGE TO REMAIN 378.1 SF 7 OCCUP. / 60 SF PROP DISPLAY AREA 51.9 SF 1 OCCUP. / 60 SF PHOTO BOOTH -1 50.7 SF1 OCCUP./ 60 SF PHOTO BOOTH -3 1 1 21 1 FE (E) CODE ANALYSIS 1. OCCUPANCY REQUIREMENTS OCCUPANCY : OCCUPANCY CALCULATIONS: (CBC TABLE 1004.1.2) TOTAL OCCUPANT LOAD: M: MERCHANTILE B: BUSINESS S-1: MODERATE-HAZARD STORAGE 1:60SF GROSS (MERCHANTILE) 1:150SF GROSS (BUSINESS AREAS) 1:300SF GROSS (STORAGE) 12 OCCUPANTS 2. EGRESS REQUIREMENTS MAX. AREA FOR LESS THAN TWO EXITS PER ROOM: COMMON PATH OF EGRESS TRAVEL (CBC TABLE 1006.2.1): EXIT ACCESS TRAVEL DISTANCE (CBC TABLE 1017.2): (CBC TABLE 1006.2.1) MERCHANTILE: 49 OCC. @ 1:60SF = 2,940 SF BUSINESS AREAS: 49 OCC. @ 1:150SF = 7,350 SF STORAGE: 49 OCC. @ 1:300SF = 14,700 SF M: 75' W/ SPRINKLER B: 75' W/ SPRINKLER S: 75' W/ SPRINKLER M: 250' W/ SPRINKLER B: 300' W/ SPRINKLER S-1: 250' W/ SPRINKLER 1. SEE DOOR DETAILS DRAWINGS FOR GENERAL NOTES REGARDING DOORS TYPICAL. 2. IN ADDITION TO OTHER CODE PROVISIONS, ALL EGRESS ILLUMINATION SHALL ALSO BE IN ACCORDANCE WITH CBC & CFC. 3. WINDOWS LOCATED IN RATED CORRIDOR WALLS SHALL BE LISTED AND LABELED FOR A FIRE PROTECTION OF 3/4 HOUR AND COMPLY WITH CBC. 4. AISLES LEADING TO REQUIRED EXITS SHALL HAVE A MINIMUM WIDTH OF 44" AND WALKWAYS WITH A MINIMUM WIDTH OF 48" SHALL BE MAINTAINED CONTINUOUSLY TO A PUBLIC WAY. 5. EXIT PATH LIGHTING SHALL BE PROVIDED FOR STAIRWAYS, HALLWAYS, EXIT PASSAGEWAYS AND EGRESS TO A PUBLIC WAY ANY TIME THE BUILDING IS OCCUPIED. 6. THE MEANS OF EGRESS, INCLUDING STAIRWAYS, HALLWAYS, EXIT PASSAGEWAYS, THE EXIT DISCHARGE AND EGRESS TO A PUBLIC WAY SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE AT THE WALKING SURFACE. 7. ROOM CAPACITY SIGNS AS REQUIRED BY TITLE 24 PART 2 SHALL BE POSTED IN THE STRUCTURE PRIOR TO ANY OCCUPANCY. 8. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2". WHEN CHANGES DO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2 EXCEPT LEVEL CHANGES NOT EXCEEDING 1/4" MAY BE VERTICAL. 9. IN BUILDINGS AND FACILITIES, FLOORS OF A GIVEN STORY SHALL BE A COMMON LEVEL THROUGHOUT, OR SHALL BE CONNECTED BY PEDESTRIAN RAMPS, PASSENGER ELEVATORS, OR SPECIAL ACCESS LIFTS. 10. MAINTAIN EXIT AISLES 44" WIDE MINIMUM AT ALL PUBLIC AREAS. 11. CORRIDORS SHALL NOT BE INTERRUPTED BY INTERVENING ROOMS. 12. EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER OR AUTHORIZED AGENT. CBC 1004.3 AND CFC 1004.3. 13. EXIT SIGNS ILLUMINATED BY AN EXTERNAL SOURCE SHALL HAVE AN INTENSITY OF NOT LESS THAN 5 FOOT CANDLES (54 IUX). 14. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. 15. EXIT SIGNS SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM THAT WILL PROVIDE AN ILLUMINATION OF NOT LESS THAN 90 MIN. IN CASE OF PRIMARY POWER LOSS (1011.2-1011.5.3) 16. EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. SEE 1008.1.8.3 FOR EXCEPTIONS. 17. FRONT DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. 18. PROVIDE INTERIOR SIGNS IDENTIFYING PERMANENT ROOMS AND SPACE PER 11B-703.1. MEANS OF EGRESS NOTES 1/4" = 1'-0"A0.80 1 LIFE SAFETY/EGRESS PLAN 1. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2AWITHIN 75 FOOT TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING ON EACH FLOOR, AND ADDITIONAL EXTINGUISHERS AS REQUIRED BY FIRE DEPARTMENTALIZED INSPECTOR OR BUILDING DEPARTMENT INSPECTOR. SEE PLANS FOR LOCATIONS. 2. PROVIDE EXIT SIGN WITH 6" LETTERS OVER REQUIRED EXITS, WHERE SHOWN ON DRAWINGS, AND ADDITIONAL SIGNS AS REQUIRED BY BUILDING DEPARTMENT INSPECTOR OR FIRE DEPARTMENT FIELD INSPECTOR. CONNECT EXIT SIGNS TO EMERGENCY POWER CIRCUITS. COMPLY WITH BUILDING CODES. 3. PROVIDE EMERGENCY LIGHTING OF ONE FOOT-CANDLE AT FLOOR LEVEL. COMPLY WITH BUILDING CODES. 4. MAINTAIN AISLES AT LEAST 44" WIDE AT PUBLIC AREAS. 5. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE. ALL NEW DOORS SHALL HAVE APPROVED LEVER HANDLES. 6. DOORS OPENING INTO REQUIRED 1-HOUR, FIRE-RESISTIVE CORRIDORS SHALL BE PROTECTED WITH A SMOKE OR DRAFT STOP ASSEMBLY HAVING A 20-MINUTE RATING AND SHALL BE SELF-CLOSING. 7. 20-MINUTE DOOR JAMBS TO BE TIGHT-FITTING, SMOKE AND DRAFT CONTROLLED. 8. EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING 50 OR MORE PERSONS AND IN ANY HAZARDOUS AREA. 9. INTERIOR WALL AND CEILING FINISHES FOR EXIT CORRIDOR SHALL NOT EXCEED AN END POINT FLAME SPREAD RATING: A. CLASS I, FLAME SPREAD 0-25, SMOKE DENSITY 450, FOR MATERIALS INSTALLED IN VERTICAL EXITS. B. CLASS II, FLAME SPREAD 26-75, SMOKE DENSITY 450, FOR MATERIALS INSTALLED IN HORIZONTAL EXITS. C. CLASS III, FLAME SPREAD 76-200, SMOKE DENSITY 450, FOR MATERIALS INSTALLED IN ANY OTHER LOCATION. 10. DECORATIONS (CURTAINS, DRAPES, SHADES, HANGINGS, ETC.) SHALL BE NON- COMBUSTIBLE OR BE FLAMEPROOFED IN AN APPROVED MANNER. 11. PROVIDE FIRE DAMPERS OR DOORS WHERE AIR DUCTS PENETRATE FIRE-RATED WALLS OR CEILINGS. 12. STORAGE, DISPENSING OR USE OF ANY FLAMMABLE OR COMBUSTIBLE LIQUIDS, FLAMMABLE GAS AND HAZARDOUS SUBSTANCES SHALL COMPLY WITH CALIFORNIA FIRE CODE REGULATIONS. 13. WOOD BLOCKING SHALL BE FIRE TREATED IN ACCORDANCE WITH APPLICABLE CODE REQUIREMENTS. 14. EXTEND OR MODIFY EXISTING FIRE/LIFE SAFETY SYSTEM AS REQUIRED TO PROVIDE AN APPROVED FIRE/ LIFE SAFETY SYSTEM. SUBMIT PLANS TO FIRE DEPARTMENT WITH COMPLETE DESCRIPTION OF SEQUENCE OF OPERATION AND OBTAIN APPROVAL PRIOR TO INSTALLATION. 15. LOCATE THE CENTER OF FIRE ALARM INITIATING DEVICES 48" ABOVE THE LEVEL OF THE FLOOR, WORKING PLATFORM, GROUND SURFACE OR SIDEWALK. COORDINATE ALL LOCATIONS IN FIELD PRIOR TO INSTALLATION. 16. EMERGENCY WARNING SYSTEMS SHALL ACTIVATE A MEANS OF WARNING THE HEARING IMPAIRED. FLASHING VISUAL WARNING SHALL HAVE A FREQUENCY OF NOT MORE THAN 60 FLASHES PER MINUTE. 17. EXTEND OR MODIFY EXISTING AUTOMATIC FIRE EXTINGUISHING SYSTEM AS REQUIRED TO PROVIDE AN APPROVED AUTOMATIC FIRE EXTINGUISHING SYSTEM. SUBMIT PLANS TO FIRE DEPARTMENT AND OBTAIN APPROVAL PRIOR TO INSTALLATION. COORDINATE INSTALLATION AND RELOCATION OF SPRINKLER HEADS WITH REFLECTED CEILING PLAN. 18. AUTOMATIC SPRINKLER SYSTEMS SHALL BE SUPERVISED BY AN APPROVED CENTRAL, PROPRIETARY OR REMOTE STATION SERVICE OR A LOCAL ALARM WHICH WILL GIVE AN AUDIBLE SIGNAL AT A CONSTANTLY ATTENDED LOCATION FIRE DEPARTMENT NOTES OCCUPANT CALCULATION ROOM NAME AREA OCCUP. TYPE OCCUP. L.F. OCCUP. # (E) STORAGE TO REMAIN 39.4 SF S 300 1 OFFICE 40.0 SF B 150 1 PHOTO BOOTH -1 51.9 SF M 60 1 PHOTO BOOTH -2 55.7 SF M 60 1 PHOTO BOOTH -3 50.7 SF M 60 1 PROP DISPLAY AREA 378.1 SF M 60 7 Grand total 12 C-33483 Date Description Project Name Project Number Description ARCHITECT: SECONEA 12440 Firestone Blvd. Suite 1017 Norwalk, CA 90650 T: 714.321.9545 www.seconea.com Info@seconea.com LEGAL NOTES: THE DRAWINGS AND SPECIFICATIONS, IDEAS, AND DESIGNS ARE AND SHALL REMAIN THE PROPERTY OF SECONEA, INC. NO PART THEREOF SHALL BE COPIED OR USED WITH ANY OTHER WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT THE WRITTEN CONSENT OF SECONEA, INC. SECONEA, INC. WAIVES ANY AND ALL RESPONSIBILITY AND LIABILITY FOR PROBLEMS WITCH ARISE FROM FAILURE TO FOLLOW THESE PLANS, SPECIFICATIONS, AND DESIGN INTENT THEY CONVEY, OR FOR PROBLEMS WHICH ARISE FROM OTHERS' FAILURE TO OBTAIN AND/OR FOLLOW THE DESIGN PROFESSIONAL'S GUIDANCE WITH RESPECT TO ANY ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR CONFLICTS WHICH ARE ALLEGED. ©2023 SECONEA 6-30-2025 A0.80 LIFE SAFETY/EGRESS PLAN 23_A12 LIFE 4 CUTS - TENANT IMPROVEMENTS LIFE 4 CUTS 400 S BALDWIN AVE. SUITE #T30, ARCADIA, CA 91007 07/21/2023 PLAN CHECK SET #1 (E) (E ) (E) (E) (E) (E ) (E ) (N) (N) (E ) (E)(E)(E) (E) (E ) (E ) 65 " (N) (E) 7'-6"H PARTITION WALL TO BE REMOVED (E) DOOR TO BE REMOVED (E) 7'-6"H PARTITION WALL TO REMAIN, TYP (E) FULL HEIGHT PARTITION WALL TO REMAIN, TYP (E) TILE FLOOR TO REMAIN (E) TILE FLOOR TO REMAIN (E) TILE FLOOR TO REMAIN (E) TILE FLOOR TO REMAIN (E) 7'-6"H PARTITION WALL TO REMAIN, TYP (E) ELEC PANLE (E) ELEC SWITCH (E) ELEC TRANSFORMER NIC (NOT IN CONTRACT) (E) FULL HEIGHT PARTITION WALL TO REMAIN (E) 7'-6" HEIGHT PARTITION WALL TO REMAIN (E) 7'-6" HEIGHT PARTITION WALL TO BE REMOVED EXISTING DEMO LEGEND (E) NIC (NOT IN CONTRACT) (E) FULL-HEIGHT PARTITION WALL (E) 7'-6" HEIGHT PARTITION WALL (N) 7'-6" HEIGHT PARTITION WALL EQUIPMENT TAG DOOR TAG 30"X48" CLEAR SPACE FINISH TRANSITION PLAN LEGEND XXXXXX 19" CLR 30 " C L R 4' - 0" CRL WALL MOUNTED DUPLEX EXISTING NEW (E) (N) XX 1. SEE ADDITIONAL DEMO NOTES ON A0.01 2. INTENT OF THE DRAWING IS TO SHOW EXISTING BUILDING CONDITIONS WITH INFORMATION DEVELOPED FROM AVAILABLE DOCUMENTS. CONTRACTOR SHALL MAKE A DETAILED SURVEY OF EXISTING CONDITIONS PERTAINING TO THE WORK BEFORE COMMENCING DEMOLITION. THE CONTRACTOR SHALL REPORT DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL FIELD CONDITIONS TO THE ARCHITECT. 3. REF. ARCHITECTURAL AND MEP DRAWINGS. COORDINATE SCOPE OF DEMOLITION WITH ARCHITECTURAL AND MEP. 4. DEMO ALL DOOR ASSEMBLIES WITHIN SCOPE, UNO 5. DEMO ALL PARTITIONS, MILLWORK, PLUMBING AND EQUIPMENT WITHIN SCOPE, UNO 6. DEMO ALL EXISTING FINISHES WITHIN SCOPE AND PREP AS REQUIRED FOR NEW FINISHES. 7. NOTIFY ARCHITECT FOR CONDITIONS RELATED TO EXTENT OF DEMO. 8. REPAIR CONDITIONS: FIRE-PROOFING 9. PROVIDE TEMPORARY BRACING FOR PARTITIONS AS REQUIRED 10. REMOVE ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING AND DEVICES, UNLESS OTHERWISE NOTED. 13. PATCH AND REPAIR SURFACES DAMAGED AS A RESULT OF ANY DEMO WORK PERFORMED. PATCH & REPAIR EXIST SURFACES AS REQ'D TO RECEIVE NEW FINISH. 14. ALL REMOVED MATERIAL OTHER THAN ITEMS TO BE SALVAGED OR REUSED SHALL BECOME CONTRACTORS PROPERTY U.N.O., AND SHALL BE REMOVED FROM OWNER'S PROPERTY. CLEAN UP AND DISPOSE OF DEBRIS PROMPTLY AND CONTINUOUSLY AS THE WORK PROGRESSES. SECURE AND PAY FOR REQUIRED HAULING PERMITS, PAY DUMPING FEES AND CHARGES. 1. SEE A0.31~A0.33 FOR ACCESSIBILITY REQUIREMENTS AND DETAILS. 2. SEE A8.11 FOR DOOR SCHEDULE AND DETAILS. 3. SEE ELECT. DWGS FOR MORE INFORMATION. 4. NOTIFY ARCHITECT IN WRITING OF CONFLICTS, DIMENSIONAL OR OTHER DISCREPANCIES PRIOR TO PROCEEDING WITH WORK OR AREAS AFFECTED. 5. ALL INTERIOR WALLS TO RECEIVE PAINTED FINISH, UNO. 6. INSTALL METAL CORNER BEADS AT ALL EXPOSED WALLBOARD EDGES. INSTALL CASING BEADS WHEREVER WALLBOARD, PLASTER, ETC. ABUTS A DISSIMILAR FINISH MATERIAL & PROVIDE SEALANT AS REQ'D. 7. SEE 2/A8.11 FOR BACKING DETAIL 8. USE 5/8' TYPE "X" GYP BOARD THROUGHOUT, UNO 9. PROVIDE EXTRA STUDS AS REQUIRED TO MOUNT ELECTRICAL OR MECHANICAL CONTROLS. INSURE STUDS REMAIN PLUMB. CRIMP OR SCREW ATTACH TO RUNNERS AS REQUIRED. 10. ALL GLASS INCLUDING MIRROR GLASS TO BE TEMPERED. ALL EXPOSED EDGES SHALL BE POLISHED. 11. PREP SLAB AS REQUIRED FOR SPECIFIED FINISH. 12. PATCH AND REPAIR SURFACES DAMAGED AS A RESULT OF WORK PERFORMED ON THIS PROJECT. PATCH & REPAIR EXIST SURFACES AS REQ'D TO RECEIVE NEW FINISH. 13. GC COORDINATE EQUIPMENT INSTALLATION (MONITORS, COMPUTERS, TVS, SERVER CABINET AND DATA RACK, ETC) AND POWER/DATA REQUIREMENTS PRIOR TO START CONSTRUCTION. 14. REFER TO INTERIOR ELEVATIONS FOR COMPLETE MILLWORK LAYOUTS. 15. FLOORING INSTALLER TO USE FLOOR PATCH/TRIM WHERE NECESSARY TO ACCOMMODATE FLOOR HEIGHT TRANSITIONS WHERE MULTIPLE MATERIALS OF DIFFERENT THICKNESSES OCCUR, UNO. 16. EXISTING FINISHES IN AREAS INDICATED AS N.I.C. ARE TO BE PROTECTED IN PLACE. 17. GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES AND IN ACCESSIBLE ROOMS AND SPACES INCLUDING FLOORS, WALKS, RAMPS STAIRS AND CURB RAMPS SHALL BE STABLE, FIRM AND SLIP RESISTANT. 18. FIRE RATING FOR EXISTING STRUCTURE IS TO BE MAINTAINED, TYP. REPAIR AS REQUIRED WHERE DAMAGED. 19. PROVIDE 4"H WD BASE PER 8/A8.11 AND PTD PER SCHED. ON ALL INT. WALLS, UNO. PHOTO BOOTH -2 OFFICE (E) STORAGE TO REMAIN PROP DISPLAY AREA PHOTO BOOTH -1 PHOTO BOOTH -3 7' - 1" 1' - 7" 7' - 0" 1' - 7" 7' - 10" 6' - 8 1/2" 1' - 0" A3.01 1 OP E N I N G , T Y P 3'- 0 " x 6 ' x 8 " 1' - 0" (E) TILE FLOOR (E) TILE FLOOR (E) TILE FLOOR (E) TILE FLOOR (N) ARTIFITIAL TURF FLOOR FINISH (E) TILE FLOOR (N) PROP DISPLAY TABLE FURNITURE, TYP 8' - 5 1 / 4 " 8 ' - 4 1 / 4 " 6' - 6 1 / 2 " 8 ' - 0 " 23 (N) PROP DISPLAY SHELF, TYP (N) MIRROR, TYP (N) MIRROR, TYP (E) EXIT DOOR (E) DOOR (E) 7'-6"H PARTITION WALL TO REMAIN, TYP (N) 7'-6"H PARTITION WALL, TYP 8 A8.11 TYP ________________ (N) PROP DISPLAY TABLE FURNITURE, TYP N1 E E (E) ELEC PANELS (E) TILE FLOOR (E) ELEC TRANSFORMER (E) FLOOR SINK (E) HAND SINK EQ-1 EQ-1 EQ-1 1 A8.11 TYP ________________ 3 A8.11 TYP ________________ ________________ TYP 7A8.11 PROVIDE MTL TRANSITION STRIP. (E) ELEC SWITCH 3/8" = 1'-0"A1.01 2 DEMOLITION PLAN DEMOLITION NOTES CONSTRUCT. NOTES C-33483 Date Description Project Name Project Number Description ARCHITECT: SECONEA 12440 Firestone Blvd. Suite 1017 Norwalk, CA 90650 T: 714.321.9545 www.seconea.com Info@seconea.com LEGAL NOTES: THE DRAWINGS AND SPECIFICATIONS, IDEAS, AND DESIGNS ARE AND SHALL REMAIN THE PROPERTY OF SECONEA, INC. NO PART THEREOF SHALL BE COPIED OR USED WITH ANY OTHER WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT THE WRITTEN CONSENT OF SECONEA, INC. SECONEA, INC. WAIVES ANY AND ALL RESPONSIBILITY AND LIABILITY FOR PROBLEMS WITCH ARISE FROM FAILURE TO FOLLOW THESE PLANS, SPECIFICATIONS, AND DESIGN INTENT THEY CONVEY, OR FOR PROBLEMS WHICH ARISE FROM OTHERS' FAILURE TO OBTAIN AND/OR FOLLOW THE DESIGN PROFESSIONAL'S GUIDANCE WITH RESPECT TO ANY ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR CONFLICTS WHICH ARE ALLEGED. ©2023 SECONEA 6-30-2025 A1.01 DEMO AND CONSTRUCTION PLANS 23_A12 LIFE 4 CUTS - TENANT IMPROVEMENTS LIFE 4 CUTS 400 S BALDWIN AVE. SUITE #T30, ARCADIA, CA 91007 3/8" = 1'-0"A1.01 1 CONSTRUCTION PLAN EQUIPMENT SCHEDULE MARK DESCRIPTION MODEL ELEC REMARK EQ-1 INSTANT PHOTO KIOSK LK-MODEL 02 110~220 V/ 60HZ / 500W CORDED 07/21/2023 PLAN CHECK SET #1 (E ) (E)(E)(E) (E) (N) (E) (E) (E) 10' - 10" SHOW WD. 10' - 10" SHOW WD.SHOW WD.SHOW WD. (E) (E)(E)(E) (E) GYP. CEILING TO REMAIN (E) ACP TO REMAIN NIC (E) (N) 2X4 PENDANT LED LIGHT, TYP OF EQ-1 BELOW OF EQ-1 BELOW OF EQ-1 BELOW (N) F-2 (N) F-2 (N) F-2 (E) F-0 (E) F-0 (E) F-0 (E) F-0(E) F-0 (E) F-0 (E) F-0 (E) F-0(E) F-0(E) F-0 (E) F-0 (E) F-0(E) F-0(E) F-0 (E) F-0(E) F-0(E) F-0 (E) F-0 (E) F-0 (N) F-1 (E) F-0 (E) F-0 (E) F-0 (E) F-0 (E) (N)EMERGENCY LIGHT NIC (NOT IN CONTRACT) (E) GYPSUM BOARD CEILING TO REMAIN (E) ACOUSTIC CEILING PANEL FLAT PANEL LED LIGHT RECESSED LED LIGHT CEILING MOUNTED DUPLEX, MAX 18" ABOVE STOREFRONT WALL MOUNTED DUPLEX SUPPLY AIR RETURN AIR RCP LEGEND SHOW WD. EXISTING NEW (E) (N) EXIT SIGN EMERGENCY LIGHT W/ 90MIN BATTERY BACKUP 3/8" = 1'-0"A1.02 1 REFLECTED CEILING PLAN RCP NOTES C-33483 Date Description Project Name Project Number Description ARCHITECT: SECONEA 12440 Firestone Blvd. Suite 1017 Norwalk, CA 90650 T: 714.321.9545 www.seconea.com Info@seconea.com LEGAL NOTES: THE DRAWINGS AND SPECIFICATIONS, IDEAS, AND DESIGNS ARE AND SHALL REMAIN THE PROPERTY OF SECONEA, INC. NO PART THEREOF SHALL BE COPIED OR USED WITH ANY OTHER WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT THE WRITTEN CONSENT OF SECONEA, INC. SECONEA, INC. WAIVES ANY AND ALL RESPONSIBILITY AND LIABILITY FOR PROBLEMS WITCH ARISE FROM FAILURE TO FOLLOW THESE PLANS, SPECIFICATIONS, AND DESIGN INTENT THEY CONVEY, OR FOR PROBLEMS WHICH ARISE FROM OTHERS' FAILURE TO OBTAIN AND/OR FOLLOW THE DESIGN PROFESSIONAL'S GUIDANCE WITH RESPECT TO ANY ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR CONFLICTS WHICH ARE ALLEGED. ©2023 SECONEA 6-30-2025 A1.02 REFLECTED CEILING PLAN 23_A12 LIFE 4 CUTS - TENANT IMPROVEMENTS LIFE 4 CUTS 400 S BALDWIN AVE. SUITE #T30, ARCADIA, CA 91007 1. SEE ELECT. DRAWINGS FOR MORE INFORMATION. 2. FIRE SPRINKLER SYSTEM MUST BE APPROVED BY FIRE DEPARTMENT PRIOR TO INSTALLATION. 3. SUSPENDED CEILINGS SHALL COMPLY WITH CBC SECTION 808 AND ASCE 13.5.6. 4. GC SHALL BE RESPONSIBLE TO COORD. THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK TO ENSURE THAT PROPER CLEARANCES FOR DUCTS, LIGHTS, PIPING, ETC. ARE MET AND THAT THE CEILING HEIGHTS NOTED ON THE DRAWING ARE MAINTAINED. LIGHTING FIXTURE SCHEDULE MARK DESCRIPTION MANUFACTURER MODEL ELEC FINISH. REMARK (E) F-0 RECESSED LED DOWN LIGHT 120V / 19 W / 5,000K TBD EXISTING TO REMAIN, PROVIDE DIMMER PER ELEC DWG (N) F-1 2X2 LED RECESSED PANEL LIGHT COOPER LIGHTING OR EQUAL METALUX 120-277V / 15 W / 5,000K TBD (N) F-2 2X4 LED PENDANT PANEL LIGHT COOPER LIGHTING OR EQUAL METALUX 120-277V / 32 W / 5,000K TBD 07/21/2023 PLAN CHECK SET #1 FIN. FL 0' - 0" CEILING 10' - 10" TY P . P A R T I T I O N W A L L 7' - 6 " OP E N I N G 6' - 8 " M I N 4" W D B A S E T Y P (N) MIRROR (N) MIRROR (N) PROP SHELF PAINTED, TYP PAINTED, TYP PAINTED, TYP FIN. FL 0' - 0" CEILING 10' - 10" OPEN TO BEYOND 7' - 6 " ARTIFITIAL TURF WALL FINISH 4" W D B A S E T Y P PAINTED, TYP PAINTED, TYP (N) MIRROR FIN. FL 0' - 0" CEILING 10' - 10" 7' - 6 " OPEN TO BEYOND OPEN TO BEYOND 4" W D B A S E T Y P PAINTED, TYP PAINTED, TYP (N) MIRROR(N) PROP SHELF (N) PROP SHELF C-33483 Date Description Project Name Project Number Description ARCHITECT: SECONEA 12440 Firestone Blvd. Suite 1017 Norwalk, CA 90650 T: 714.321.9545 www.seconea.com Info@seconea.com LEGAL NOTES: THE DRAWINGS AND SPECIFICATIONS, IDEAS, AND DESIGNS ARE AND SHALL REMAIN THE PROPERTY OF SECONEA, INC. NO PART THEREOF SHALL BE COPIED OR USED WITH ANY OTHER WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT THE WRITTEN CONSENT OF SECONEA, INC. SECONEA, INC. WAIVES ANY AND ALL RESPONSIBILITY AND LIABILITY FOR PROBLEMS WITCH ARISE FROM FAILURE TO FOLLOW THESE PLANS, SPECIFICATIONS, AND DESIGN INTENT THEY CONVEY, OR FOR PROBLEMS WHICH ARISE FROM OTHERS' FAILURE TO OBTAIN AND/OR FOLLOW THE DESIGN PROFESSIONAL'S GUIDANCE WITH RESPECT TO ANY ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR CONFLICTS WHICH ARE ALLEGED. ©2023 SECONEA 6-30-2025 A3.01 INT ELEVATIONS 23_A12 LIFE 4 CUTS - TENANT IMPROVEMENTS LIFE 4 CUTS 400 S BALDWIN AVE. SUITE #T30, ARCADIA, CA 91007 3/8" = 1'-0"A3.01 1 INTERIOR ELEVATION -1 3/8" = 1'-0"A3.01 2 INTERIOR ELEVATION -2 3/8" = 1'-0"A3.01 3 INTERIOR ELEVATION -3 1. ALL INTERIOR WALLS TO RECEIVE PAINTED FINISH AND 4"H PAINTED WD BASE, UNO. FINISH NOTES 07/21/2023 PLAN CHECK SET #1 TYP1 1 BASE CABINET, WALL HUNG CABINET, SHELVES, LAVORATORY, GRAB BAR, ELECTRICAL PANEL, TELEVISION, SURFACE MOUNTED LIGHT FIXTURE AND AS SHOWN. 6" X 20 GA. STL. STUD NOTCH & FASTEN FLUSH TO STUDS W/ (2) 8-18 WAFER HEAD SELF DRILLING SCREWS PER STUD. ALL BACKING TO SPAN MINIMUM THREE STUDS. TYPE 2 ALL TOILET ACCESSORIES, FIRE ALL TOILET ACCESSORIES, FIRE MOUNTED TELEPHONE OUTLET, WALL MOUNTED DOOR STOP, WINDOW BLIND, AND AS SHOWN. 20 CA. STUD 16" 16" 20 CA. STUD 16" 16" 6" X 16 GA. STL. PLATE FASTEN FLASH TO STUDS W/ (2) 8-18 WAFER HEAD SELF DRILLING SCREWS PER STUD. ALL BACKING TO SPAN MIN. THREE STUDS.NOTE: 1.EXTEND BACKING PLATES TO LAST STUD BEYOND FACE OF FIXTURE OR ACCESSORY, TYP. 2.PROVIDE METAL SLEEVES THROUGH WALL FINISH AT FIXTURE FASTENING, TYP. 3.ALL BACKING PLATES SHOWN OR NOT SHALL BE SCREWED TO STUDS, TYP. MTL. TRACK W/ 2-#10 TEKS ATTACHED @ EA. 16" O.C. STUD AS REQ. (ICC-ESR 3016) SEE 1A/8.11 FOR TYPICAL PARTITION SILL DETAIL PROVIDE HILTI X-U POWDER DRIVEN FASTENER @ 24" O.C. W/ 1 1/2" MIN EMBED (ICC-ESR 2269) SEE ARCHITECTURAL FOR FINISH 3 5/8", 20 GA METAL STUDS @ 16" OC (ICC-ESR 4782) SLAB 5/8" TYPE X GYP. BD. EACH SIDE PE R P L A N 16 GA TRACK W/ 2" LEG CONNECTED TO 16 GA CEE-STUD #12 SMS @ 6" O.C. EACH SIDE, TYP 16 GA TRACK METAL STUDS #12 SMS @ 6" O.C. A -TYPICAL SILL DETAIL PARTITION PER PLAN WOOD BASE, PTD (SEMI-GLOSS FINISH, TYP) SCHEDULED FLOOR FINISH. 4" TYPE A 3' - 2 " T Y P . SE E S C H E D U L E SEE SCHEDULE METAL STUDS METAL STUDS TRACK (2) #10 SCREWS EACH STUD, TYP. #10 SCREWS @ 16" O.C., TYP. (2) METAL STUDS THAT MATCH SIZE & GAGE OF SCHEDULED PARTITIONS METAL STUD TRACK, GAGE TO MATCH SCHEDULED PARTITION W/ #10 SCREWS @ 16" O.C. EACH SIDE, TYP. METAL STUDS METAL STUDS TRACK (2) #10 SCREWS EACH STUD, TYP. A -TYPICAL HEAD DETAIL A1 A2 PL. 16GA x 3" SQ. W/ (4) #10 SMS @ 12" O.C. EACH SIDE, FULL HEIGHT, TYP. PL. 16GA x 3" SQ. W/ (4) #10 SMS @ 12" O.C., FULL HEIGHT, TYP. CLIP ANGLE 4 x 4 x 16GA EACH SIDE, TYP. (2) 0.157" DIA. HILTI X-U SHOT PIN W/ 1-1/2" MIN. EMBEDMENT, TYP. (3) #10 SMS, TYP. BOTTOM TRACK B -TYPICAL JAMB DETAIL ALTERNATE B1 B2 20 GA STEEL STUDS @ DOOR OPENING, TYP. DOUBLE REINFORCING FLOOR ANCHOR CLIPS SECURED TO FLOOR WITH NO LESS THAN TWO (2) SUITABLE FASTENERS SPACED NO LESS THAN 3" APART RUNNERS FASTENED WITH SCREWS TO STUDS (AT HEIGHT PERMITTING SCREW ATTACHMENT OF FACING) LOCATE JAMB ANCHOR CLIPS ABOVE HINGE REINFORCEMENTS AND JUST BELOW TOP REINFORCEMENTS - CLIPS ON STRIKE SIDE TO OCCUR DIRECTLY OPPOSITE OF HINGE SIDE 4 A8.11 4 A8.11 4 A8.11 VA R I E S 1/ 2 " 2"5/8" 2" 1/ 2 " 2" 2" 0' STEEL FRAME METAL ANCHOR JOINT SEALANT JOINT SEALANT SCHEDULED DOOR; LINE OF FRAME HEADER ABOVE SCHEDULED PARTITION; REFER TO CONSTRUCTION PLAN, CONTRACTOR TO VERIFY THICKNESS FINISH PER SCHEDULE, WHERE OCCURS ALIGN SEE 2/A8.10 FOR FRAMNG VARIES VIF 1/2"1/2" 5" 2" 5/ 8 " 1 15/16"1 15/16" 4" SCHEDULED DOOR; REFER TO DOOR SCHEDULE SCHEDULED CEILING; REFER TO CEILING PLAN SCHEDULED PARTITION; REFER TO CONSTRUCTION PLAN CONTRACTOR TO VERIFY THICKNESS FINISH PER SCHEDULE WHERE OCCURS AL I G N SEE 2/A8.10 FOR FRAMNG C-33483 Date Description Project Name Project Number Description ARCHITECT: SECONEA 12440 Firestone Blvd. Suite 1017 Norwalk, CA 90650 T: 714.321.9545 www.seconea.com Info@seconea.com LEGAL NOTES: THE DRAWINGS AND SPECIFICATIONS, IDEAS, AND DESIGNS ARE AND SHALL REMAIN THE PROPERTY OF SECONEA, INC. NO PART THEREOF SHALL BE COPIED OR USED WITH ANY OTHER WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT THE WRITTEN CONSENT OF SECONEA, INC. SECONEA, INC. WAIVES ANY AND ALL RESPONSIBILITY AND LIABILITY FOR PROBLEMS WITCH ARISE FROM FAILURE TO FOLLOW THESE PLANS, SPECIFICATIONS, AND DESIGN INTENT THEY CONVEY, OR FOR PROBLEMS WHICH ARISE FROM OTHERS' FAILURE TO OBTAIN AND/OR FOLLOW THE DESIGN PROFESSIONAL'S GUIDANCE WITH RESPECT TO ANY ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR CONFLICTS WHICH ARE ALLEGED. ©2023 SECONEA 6-30-2025 A8.11 DETAILS AND DOOR TYPE AND SCHEDULE 23_A12 LIFE 4 CUTS - TENANT IMPROVEMENTS LIFE 4 CUTS 400 S BALDWIN AVE. SUITE #T30, ARCADIA, CA 91007 3" = 1'-0"A8.11 2 BACKING PLATE PARTITION NOTES: 1. USE 5/8" TYPE "X" GYP. BOARD UNLESS NOTED OTHERWISE. 2. USE GLASS-MAT WATER-RESISTANT BACKER BOARD IN LIEU OF TYPE 'X' GYPSUM BOARD WHERE WALL TILE FINISH OCCURS OR AT WALL BEHIND PLUMBING FIXTURES. 3. SEE FINISH SCHEDULE (2/A1.02) AND INTERIOR ELEVATIONS AND FINISH PLANS FOR FINISH MATERIAL APPLIED TO WALLS. 4. NO JOINTS EXCEPT AT STUDS. 5. DRYWALL SCREW EDGE AND FIELD SPACING PER GYPSUM BOARD MANUFACTURER'S RECOMMENDATIONS. ALL SCREWS SHALL PENETRATE STUDS. 6. BATT INSULATION(SOUND ATTENUATION) TO EQUAL STUD DEPTH. 7. ALL PARTITIONS SHALL BE COORDINATED WITH SCHEDULED FINISHES FOR PARTITION LAYOUT AND REQUIRED CLEARANCES. 8. PROVIDE BLOCKING IN PARTITIONS FOR MILLWORK SUPPORT AS REQUIRED. SEE CONSTRUCTION PLANS AND ELEVATIONS FOR LOCATIONS. 3" = 1'-0"A8.11 1 TYP. INT. PARTITION DETAIL 6" = 1'-0"A8.11 8 WOOD WALL BASE DOOR AND FRAME SCHEDULE DOOR ASSEMBLY DOOR MATERIAL FRAME MATERIAL REMARKSNUMBER LOCATION TYPE DIMENSIONS MATERIAL FINISH MATERIAL FINISHWIDTH HEIGHT THICK. N1 OFFICE A 3' - 0" 6' - 8" 1 3/4" WD TBD WD TBD GC TO PROVIDE H.W. PER CLIENT LEGEND GL: GLASS WD: WOOD SC: SOLID CORE HM: HOLLOW METAL SS: STAINLESS STEEL 1/4" = 1'-0" DOOR TYPES DOOR NOTES 1. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT.CBC 1010.1.9. 2. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE. ALL NEW DOORS SHALL HAVE APPROVED LEVER HANDLES. 3. SEE A0.31-33 FOR ACCESSIBILITY REQUIREMENTS. 4. G.C. TO PROVIDE COMPLETE DOOR/HARDWARE PACKAGE TO FUNCTION AS INDICATED. ALL DOORS AND HARDWARE SHALL BE BUILDING STANDARD, U.O.N. SUBMIT COMPLETE SPECS TO ARCHITECT FOR REVIEW AND APPROVAL. 5. ALL HARDWARE TO MEET TITLE 24 AND ACCESSIBILITY REQUIREMENTS. SEE REQUIRED DOOR CLEARANCES AND MOUNTING HEIGHTS ON A0.30-34. 6. CONTRACTOR TO FIELD VERIFY CONDITION, HAND, THROAT SIZE AND WORKABILITY OF ALL DOORS AND HARDWARE; REPAIR OR REPLACE AS REQUIRED. 7. LOCK CYLINDERS AND KEYS SHALL BE COORDINATED WITH BUILDING OWNER. 8. BOTTOM OF 10" OF ALL DOORS EXCEPT AUTOMATIC, SLIDING, ROLLUP, SECTIONAL, SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION (CBC SEC 11B-404.2.10). 9. ALL GLAZING SHALL BE TEMPERED, ALL EXPOSED EDGES SHALL BE POLISHED. GLAZING INCLUDING CLASS MIRRORS WITHIN A 24" ARC OF EITHER SIDE OR DOORS MUST BE OF SAFETY GLAZING MATERIAL (CBC SEC.2406). 10. ALL DOOR FRAMES AND PANELS TO BE FINISHED TO MATCH ADJACENT WALL FINISH UNO. 11. RATED DOOR UNDERCUTS SHALL NOT EXCEED MAX ALLOWABLE PER NFPA 80 12. THE MINIMUM WIDTH OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE OCCUPANT LOAD THEREOF AND SHALL PROVIDE A CLEAR WIDTH OF NOT LESS THAN 32 INCHES. THE HEIGHT OF DOORS SHALL NOT BE LESS THAN 80 INCHES. CBC 1008.1.1. 13. FRONT DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED 14. HAND-ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 35" AND 44" A.F.F. LATCHING AND LOCKING DOORS THAT ARE HAND-ACTIVATED AND ARE IN THE PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER-TYPE HARDWARE, PANIC BARS OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE HARDWARE (CBC SEC.11B-404.2.7). 3" = 1'-0"A8.11 4 TYPICAL DOOR HEAD & JAMB FRAMING 1 1/2" = 1'-0"A8.11 3 TYPICAL DOOR AND OPENING FRAMING 3" = 1'-0"A8.11 7 HM DOOR JAMB 3" = 1'-0"A8.11 6 HM DOOR HEADER 07/21/2023 PLAN CHECK SET #1 E-mail: pc.philchon@gmail.com 5415 Burning Tree Dr TEL : 213.453.7188 /D&DxDGD)OLQWULGJH&$ LI F E 4 C U T S E-1 E-mail: pc.philchon@gmail.com 5415 Burning Tree Dr TEL : 213.453.7188 /D&DxDGD)OLQWULGJH&$ LI F E 4 C U T S E-2 E-mail: pc.philchon@gmail.com 5415 Burning Tree Dr TEL : 213.453.7188 /D&DxDGD)OLQWULGJH&$ LI F E 4 C U T S E-3