HomeMy WebLinkAbout285 W Huntington Dr - 2023 - Santa Anita Race Track Walkin in CoolerGENERAL NOTES SCALE N.T.S.15 A. THIS PROJECT SHALL COMPLY WITH THE TECHNICAL REQUIREMENTS CONTAINED IN THE 2019 BUILDING CODE, 2019 CALIFORNIA BUILDING CODE, 2019 CALIFORNIA PLUMBING CODE, 2019 MECHANICAL CODE, 2019 CALIFORNIA ELECTRICAL CODE, 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE, 2019 CALIFORNIA FIRE CODE, 2019 CALIFORNIA ENERGY CODE AND THEIR AMENDMENTS, INCLUDING CALIFORNIA STATE LAW. B. IT IS INTENDED THAT A COMPLETE OCCUPIABLE BUILDING PROJECT IS PROVIDED. C. THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION (A.I.A. LATEST EDITION) ARE A PART OF THESE CONTRACT DOCUMENTS. A COPY IS ON FILE AT THE ARCHITECT'S OFFICE. D. DUE TO THE NATURE OF THE WORK, ALL DIMENSIONS SHOWN SHALL BE CONSIDERED APPROXIMATE. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO BEGINNING CONSTRUCTION. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW PRIOR TO FABRICATION OF ANY ITEM. FAILURE TO ADHERE TO THIS PROCEDURE SHALL PLACE FULL RESPONSIBILITY FOR ANY ERRORS DIRECTLY UPON THE CONTRACTOR. E. INFORMATION CONCERNING EXISTING BUILDING STRUCTURE, SIZE, LOCATION OF EQUIPMENT, FINISHES, ETC. WAS OBTAINED FROM VARIOUS PLANS FOR CONSTRUCTION OF THE EXISTING BUILDING. EVERY EFFORT HAS BEEN MADE TO ACCURATELY DEPICT EXISTING CONDITIONS, HOWEVER ALL WORK MUST BE VERIFIED IN THE FIELD PRIOR TO CONSTRUCTION. ANY CONFLICT BETWEEN THESE PLANS AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED IMMEDIATELY TO THE ARCHITECT FOR VERIFICATION AND/OR CORRECTION F. DO NOT SCALE THESE DRAWINGS. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ANY DISCREPANCIES IN THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO STARTING WORK. G. ALL PROPOSED SUBSTITUTIONS SHALL BE APPROVED BY THE ARCHITECT, IN WRITING, PRIOR TO INSTALLATION. H. THE GENERAL CONTRACTOR SHALL USE EXTREME CAUTION IN DEMOLITION OF EXISTING CONSTRUCTION. ANY ITEM STRUCTURAL IN NATURE AND SCHEDULED FOR DEMOLITION IN THIS DRAWING BUT NOT IDENTIFIED AS STRUCTURAL IN NATURE SHALL BE VERIFIED WITH THE ARCHITECT PRIOR TO DEMOLITION. BY FAILURE TO DO SO,THE CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR THE CONSEQUENCES OF SUCH ACTION. I. G.C. IS RESPONSIBLE FOR OBTAINING ALL PERMITS ASSOCIATED WITH THE PROJECT. THIS INCLUDES, BUT IS NOT LIMITED TO ELECTRICAL, MECHANICAL, PLUMBING, FIRE SPRINKLER, HOOD ANSUL, OR OTHER RELATED FIRE PERMITS, ENCROACHMENT PERMIT, ETC. OWNER WILL PAY FOR "CONNECTION FEES" ASSOCIATED WITH UTILITY PERMITS. OWNER IS REQUIRED TO PAY FOR TEMPORARY FACILITIES FEES AS REQUIRED TO COMPLETE THE WORK IN A TIMELY MANNER. J. G.C. SHALL PROVIDE EACH SUBCONTRACTOR WITH A COMPLETE AGENCY-PERMITTED DRAWING SET AT TIME OF CONSTRUCTION. K. THE CONTRACTOR SHALL SHORE AND/OR UNDERPIN EXISTING WORK AS REQUIRED TO SAFELY INSTALL NEW WORK. THIS WORK SHALL BE THE FULL RESPONSIBILITY OF THE CONTRACTOR AND NO ACT, DIRECTION OR REVIEW OF ANY SYSTEM OR METHOD BY THE ARCHITECT SHALL CHANGE OR AFFECT THE CONTRACTOR'S RESPONSIBILITY IN THIS MATTER. DEFLECTION OF EXISTING TO BE LIMITED TO 1/8" IN ORDER TO MAINTAIN INTEGRITY OF STRUCTURE. L. SCOPE OF WORK AND SPECIFICATIONS DOCUMENTS ARE INCLUDED AS CONTRACT DOCUMENTS FOR THIS PROJECT. IF THEY HAVE NOT BEEN PROVIDED TO YOU FOR THIS PROJECT PLEASE ASK THE OWNER OR THE OWNER'S REPRESENTATIVE FOR A COPY OF THE APPLICABLE SECTIONS. M. ALL MATERIALS STAGED TO BE USED FOR CONSTRUCTION SHALL BE PROTECTED FROM EXCESSIVE MOISTURE. IF THEY ARE EXPOSED TO MOISTURE THEY SHOULD BE ADEQUATELY DRIED BEFORE ENCAPSULATED INTO THE BUILDING. N. ALL PAINTS, ADHESIVES, COATINGS AND SEALANTS USED INSIDE THE BUILDING SHALL HAVE A LOW VOC CONTENT. NO PROPOSED CHANGE TO EXISTING BUILDING FOOTPRINT. O. CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING SYSTEM/COMPONENT LISTED IN THE "STATEMENT OF SPECIAL INSPECTION" SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO AUTHORITY HAVING JURISDICTION INSPECTORS AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON SUCH SYSTEM OR COMPONENT PER SEC 1709.1. A. THIS PROJECT SHALL COMPLY WITH THE TECHNICAL REQUIREMENTS CONTAINED IN THE 2022 BUILDING B. IT IS INTENDED THAT A COMPLETE OCCUPIABLE BUILDING PROJECT IS PROVIDED. C. THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION (A.I.A. LATEST EDITION) ARE A D. DUE TO THE NATURE OF THE WORK, ALL DIMENSIONS SHOWN SHALL BE CONSIDERED APPROXIMATE. E. INFORMATION CONCERNING EXISTING BUILDING STRUCTURE, SIZE, LOCATION OF EQUIPMENT, F. DO NOT SCALE THESE DRAWINGS. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ANY G. ALL PROPOSED SUBSTITUTIONS SHALL BE APPROVED BY THE ARCHITECT, IN WRITING, PRIOR TO H. THE GENERAL CONTRACTOR SHALL USE EXTREME CAUTION IN DEMOLITION OF EXISTING I. G.C. IS RESPONSIBLE FOR OBTAINING ALL PERMITS ASSOCIATED WITH THE PROJECT. THIS INCLUDES, J. G.C. SHALL PROVIDE EACH SUBCONTRACTOR WITH A COMPLETE AGENCY-PERMITTED DRAWING SET K. THE CONTRACTOR SHALL SHORE AND/OR UNDERPIN EXISTING WORK AS REQUIRED TO SAFELY INSTALL L. SCOPE OF WORK AND SPECIFICATIONS DOCUMENTS ARE INCLUDED AS CONTRACT DOCUMENTS FOR M. ALL MATERIALS STAGED TO BE USED FOR CONSTRUCTION SHALL BE PROTECTED FROM EXCESSIVE N. ALL PAINTS, ADHESIVES, COATINGS AND SEALANTS USED INSIDE THE BUILDING SHALL HAVE A LOW O. CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING PIONEER BLVD VICINITY MAP SITE PLANN.T.S. SCALE N.T.S. SCALE No.Revision 2 3 4 5 6 Date 1 7 8 9 10 11 HEALTH10/08/22 BUILDING10/25/22 BUILDING12/20/22 BUILDING08/07/23 SA N T A A N I T A P A R K (A D D W A L K - I N C O O L E R ) 28 5 W . H U N T I N G T O N D R I V E , A R C A D I A , C A 9 1 0 0 7 --/--/----Date: Drawn By: Dwg. No: Scale: Checked By: Title: Sheet No. . . AS SHOWN Jo b N a m e & A d d r e s s : MJ The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of NEW ASIA FSE, INC. These are available or limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this notice. Upon acceptance and use of this drawings, the Contractor agrees to review and inform Optima Group Inc. of any discrepancy or conflict prior to the preparation of without exception, shop drawings, templates, layouts, or any execution of any work related to the information contained on this document. Notice: 3400 N. PECK ROAD, EL MONTE, CA 91731 TEL: 626-575-5880 FAX: 626-575-5080 EMAIL:SALESNEWASIA@AOL.COM NEW ASIA FSE, INC. 1 COVER SHEET A-0.0 SHEET INDEX N.T.S. SCALE 14 13 N N PROJECT PROJECT SUMMARY PROJECT ADDRESS: PROJECT DESCRIPTION: OCCUPANCY GROUP: TOTAL AREA: A-5 CONSTRUCTION TYPE:V-B N.T.S. SCALE ADD (1) WALK-IN COOLER 146 SF ·ADD (1) WALK-IN COOLER ·EXISTING (1) WALK-IN COOLER ·EXISTING (1) WALK-IN FREEZER 9 285 W. HUNTINGTON DRIVE, ARCADIA, CA 91007 2019 CALIFORNIA BUILDING CODE (2019 CBC) 2019 CALIFORNIA ELECTRICAL CODE (2019 CEC) 2019 CALIFORNIA PLUMBING CODE (2019 CPC) 2019 CALIFORNIA MECHANICAL CODE (2019 CMC) 2019 CALIFORNIA FIRE CODE (2019 CFC) 2019 CALIFORNIA ENERGY CODE CITY MUNICIPAL CODE NUMBER OF STORIES: CODE ANALYSIS: FIRE SPRINKLERED:YES CURRENT CITY/COUNTY CODE AMENDMENTS 2019 CALIFORNIA GREEN BLDG. STANDARDS CODE (2019 CGBC) PROJECT FIRST FLOOR OF 5-STORY BUILDING 2 DEFERRED SUBMITTALS: FIRE SPRINKLER AND/OR FIRE ALARM SYSTEM(ALL DEFERRED SUBMITTALS WILL BE UNDER SEPARATE PERMITS) 2 A-0.0 COVER SHEET A-0.01 ACCESSIBILITY DETAILS A-0.1 EXISTING FLOOR PLAN A-1.0 PROPOSED FLOOR PLAN & FINISH SCHEDULE & WIC / WIF DETAILS A-2.0 TITLE 24 SEE 9/A-0.01 4 NOTES SCALE N.T.S.16 WALKS & SIDEWALKS 1. WALKS AND SIDEWALKS SHALL HAVE A CONTINUOUS COMMON SURFACE NOT INTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN LEVEL EXCEEDING 1/2", AND SHALL BE A MINIMUM OF 48" IN WIDTH 2. WHEN THE SLOPE IN THE DIRECTION OF TRAVEL OF ANY WALK EXCEEDS 1 VERTICAL TO 20 HORIZONTAL 3. WALK AND SIDEWALK SURFACE CROSS SLOPES SHALL NOT EXCEED 1/4" PER FOOT. ACCESSIBLE PARKING REQUIRED 1. ACCESSIBLE PARKING SPACES SHALL BE LOCATED AS NEAR AS PRACTICAL TO A PRIMARY ENTRANCE AND SHALL BE SIZED AS SHOWN. 2. WHERE SINGLE SPACES ARE PROVIDED, THEY SHALL BE 14 FEET WIDE AND OUTLINED TO PROVIDE A 9-FOOT PARKING AREA AND A 5-FOOT LOADING AND UNLOADING ACCESS AISLE ON THE PASSENGER SIDE OF THE VEHICLE. 1 IN EVERY 8 ACCESSIBLE SPACES, BUT NOT LESS THAN 1, SHALL BE SERVED BY AN ACCESS AISLE 96 INCHES WIDE MIN. & SHALL BE DESIGNATED VAN ACCESSIBLE AS REQUIRED BY CH.11B ALL SUCH SPACES MAY BE GROUPED ON 1 LEVEL OF A PARKING STRUCTURE. PARKING SIGN 1. THE SIGN SHALL NOT BE SMALLER THAN 70 SQUARE INCHES IN AREA AND, WHEN IN PATH OF TRAVEL, SHALL BE POSTED AT A MINIMUM HEIGHT OF 80 INCHES FROM THE BOTTOM OF THE SIGN TO THE PARKING SPACE FINISHED GRADE AND SHALL BE UNOBSCURED BY A PARKED VEHICLE. 2. SIGNS MAY ALSO BE CENTERED ON THE WALL AT THE INTERIOR END OF THE PARKING SPACE AT A MINIMUM HEIGHT OF 36 INCHES FROM THE PARKING SPACE FINISHED GRADE, GROUND OR SIDEWALK. 3. SPACES COMPLYING WITH CH.11B SHALL HAVE AN ADDITIONAL SIGN STATING "VAN-ACCESSIBLE" MOUNTED BELOW THE SYMBOL OF ACCESSIBILITY. TOWED VEHICLES MAY BE RECLAIMED AT__________________________________________________ FIRE ALARM SYSTEMS 1. FIRE ALARM SYSTEMS SHALL HAVE PERMANENTLY INSTALLED AUDIBLE AND VISIBLE ALARMS COMPLYING WITH NFPA 72 AND CBC 907.5.2.1 AND 907.5.2.3. OR BY TELEPHONING________________________________________." ELECTRICAL CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF A ROOM OR AREA TO CONTROLLIGHTING AND RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND VENTILATING EQUIPMENT SHALL BEMIN. 15" MEASURED TO THE BOTTOM OF THE OUTLET AND MAX. 48" MEASURED TO THE TOP OF THE OUTLET OTHERS SITE ACCESSIBLE ROUTE OF TRAVEL 4. THE SIGN SHALL NOT BE LESS THAN 17" X 22" IN SIZE WITH LETTERING NOT LESS THAN 1-INCH IN HEIGHT, WHICH CLEARLY AND CONSPICUOUSLY STATES THE FOLLOWING: "UNAUTHORIZED" VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER’S EXPENSE. SITE ACCESSIBLE ROUTE OF TRAVEL 60 ` ` appropriate signage. At lease one accessible route within the boundary of the state is provided to an accessible building entrance from: Public transportation stops Accessible parking spaces Accessible passenger loading zones Public streets and sidewalks At every primary public entrance and at every major junction along or leading to an accessible route of travel, there shall be a sign displaying the international symbol of comply with the requirements: accessibility. Signs shall indicate the direction to accessible building entrances and facilities and shall Accessible entrances and routes of travel have Entrance signage SCALE N.T.S.15 SITE ACCESSIBLE ROUTE OF TRAVEL INTERNATIONAL SYMBOL OF ACCESSIBILITY DISTINGUISHING PLACARDS UNAUTHORIZED VEHICLES PARKED IN DESIGNATED WITH DISABILITIES OWNER'S EXPENSE. TOWED VEHICLES MAY BERECLAIMED AT OR BY TELEPHONING (Telephone Number) WILL BE TOWED AWAY AT (AGENCY) OR SPECIAL LICENCE PLATES ISSUED FOR PERSONS ACCESSIBLE SPACESNOT DISPLAYING VAN ACCESSIBLE APPROPRIATE INFORMATION MUST BE INCLUDED ON SIGN (MINIMUM OF 1" IN. HEIGHT) 1" IN. HEIGHT LETTERING ON SIGN MUST BE A MINIMUM OF 60" MIN. FOR WALL MOUNTED WALKING SURFACE TO TOP OF 80" MIN. FOR FREE STANDING C RESERVED WITH BEADED TEXT REFLECTORIZED SIGN CONSTRUCTED OF PORCELAIN STEEL BLUE OR EQUAL WHITE 1/2" RADIUS B RESERVED FINE $250 MINIMUM FINE $250 MINIMUM 36'' 36 ' ' 17'' MIN 22 ` ` M I N SIGNAGE DETAILS DOOR MOUNTED SIGNAGE (TYP.)SCALE N.T.S.13 NOTE: THE CENTERLINE OF THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE A MAXIMUM OF 6 INCHES FROM THE CENTERLINE OF THE PARKING SPACE, ITS SIDES PARALLEL TO THE LENGTH OF THE PARKING SPACE AND ITS LOWER CORNER AT, OR LOWER SIDE ALIGNED WITH, THE END OF THE PARKING SPACE LENGTH. AGENCY: TELEPHONE NUMBER: A D NOTE: SIGN TO BE CENTERED AT THE INTERIOR END OF PARKING SPACE. AREA OF SIGN TO BE A MIN. OF 70 SQ. IN. DESIGNATE FOR "VAN ACCESSIBLE" WHERE APPROPRIATE. INTERNATIONAL SYMBOL OF ACCESSIBILITY IN WHITE ON A BLUE BACKGROUND 2. 3 " - 2 . 4 " AP A R T 2.3"-2.4" APART 0.45"-0.47 AT TOP 0.9"-0.92" AT BASE TRUNCATED DOME IF A WALK CROSSES OR ADJOINS A VEHICULAR WAY, AND THE WALKING SURFACES ARE NOT SEPARATED BY CURBS, RAILINGS OR OTHER ELEMENTS BETWEEN THE PEDESTRIAN AREAS AND VEHICULAR AREAS, THE BOUNDARY BETWEEN THE AREAS SHALL BE DEFINED BY A CONTINUOUS DETECTABLE WARNING WHICH IS 36" WIDE. 0.2" HT. N.T.S. SCALE 12 0. 6 5 " M I N . ELECTRICAL CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF A ROOM OR AREA TO CONTROL DETECTABLE WARNING SURFACES SHALL BE YELLOW AND APPROXIMATE FS 33538 OF EDERAL STANDARD 595C. DOORWAYS LEADING TO TOILET ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC DOOR MOUNTED SIGNAGE (TYP.) INTERNATIONAL ACCESSIBILITY SYMBOL SCALE N.T.S.11 6" 6" EXTERIOR PLASTIC SIGN PANEL CORNER RADIUS 3/8" COLOR MATCH ROOM IDENTIFICATION SIGNS PICTOGRAM WHITE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN TO BE PLACED AT ALL ENTRANCES AND UNDER THE ROOM IDENTIFICATION SIGN OR RESTROOM IDENTIFICATION SIGN WHEN ROOM IS ACCESSIBLE. NO PARKING NO PARKING VAN-ACC. STALL SIGN TYP. CURB FACE PRECAST CONC. WHEEL STOP 13C -- 9'-0" MIN.8'-0" MIN.9'-0" MIN.9'-0" MIN.8'-0" MIN.9'-0" MIN.9'-0" MIN. 18 ' - 0 " M I N . AN Y D I R E C T I O N 2% S L O P E M A X . "NO PARKING" WHITE LETTERS 12" HI. MIN. 4" WIDE PAINTEDPARK'G STRIPES:2-COATS OF BLUE AT DISABLED STALLS-- OCCUPANT IN WHITEON BLUE BACKGROUND SHALL BE 36" WIDE TYP. 13D STRIPES AT 36" O.C. -- ACC. STALL SIGN TYP.13B(N) 6"H CURB TO SEPARATE WALKWAY AND DRIVE AISLE TRUNCATED DOMES (N) 48"x36"12 -- 48 " M I N . 48" MIN. NO P A R K I N G NO P A R K I N G No.Revision 2 3 4 5 6 Date 1 7 8 9 10 11 HEALTH10/08/22 BUILDING10/25/22 BUILDING12/20/22 BUILDING08/07/23 SA N T A A N I T A P A R K (A D D W A L K - I N C O O L E R ) 28 5 W . H U N T I N G T O N D R I V E , A R C A D I A , C A 9 1 0 0 7 --/--/----Date: Drawn By: Dwg. No: Scale: Checked By: Title: Sheet No. . . AS SHOWN Jo b N a m e & A d d r e s s : MJ The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of Optima Group Inc. These are available or limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this notice. Upon acceptance and use of this drawings, the Contractor agrees to review and inform Optima Group Inc. of any discrepancy or conflict prior to the preparation of without exception, shop drawings, templates, layouts, or any execution of any work related to the information contained on this document. Notice: COMMERCIAL / RESIDENTIAL DESIGN & GENERAL CONSTRUCTION 1217 BUENA VISTA STREET, STE 102B. DUARTE. CA 91010 ACCESSIBILITY DETAILS A-0.01 SL 8 (E) ACC. PARKING STALLS N.T.S. SCALE 1SITE PLAN N.T.S. SCALE 11 < < < >>>> > > > > > > > >> < < < < < < < TRUNCATED DOMES (2) (N) 48"x36"12 -- 1 -- 4 ACCESSIBLE PATH OF TRAVEL FROM (E) ACC. PARKING (48" MIN. WIDTH WALKWAY, 4" WIDE PAINTED BORDER: 2-COATS OF BLUE, 5% MAX. SLOPE IN THE DIRECTION OF TRAVEL, 2% MAX. CROSS-SLOPE) 15 -- HARDSHIP FORM N.T.S. SCALE 3 4,000 4,000 20,000 4,000 4,0004,000 XX X X X X X X 626-222-0621 8/7/2023PATRICK CHIU ARCHITECTURAL ENGINEER 20,000 INSTALL (2) NEW 48"x36" TRUNCATED DOMES; (N) 6"H CURB TO SEPARATE WALKWAY AND DRIVE AISLE SCALE 1/4"=1'-0"1SCALE 1/4"=1'-0"1 12 ' - 8 " 13'-4" 16 ' - 7 " 11'-2" 21 ' - 8 " 18 ' - 6 " (E) WIC (E) WIF 14'-0" (E ) S T A I R R O O M 17 ' - 0 " 10'-0" N 1' - 1 1 " 8' - 2 " (E) STORAGE (E) HORSE SHOWER ROOM (EMPLOYEES ONLY) (E ) S T O R A G E (E M P L O Y E E S O N L Y ) (E) PUBLIC AREA (E) EXTERIOR RAMP No.Revision 2 3 4 5 6 Date 1 7 8 9 10 11 HEALTH10/08/22 BUILDING10/25/22 BUILDING12/20/22 BUILDING08/07/23 SA N T A A N I T A P A R K (A D D W A L K - I N C O O L E R ) 28 5 W . H U N T I N G T O N D R I V E , A R C A D I A , C A 9 1 0 0 7 --/--/---- EXISTING FLOOR PLAN A-0.1 EXISTING FLOOR PLAN 1 AA 1 (E) F/S (E) F/S (E) 3'-0'' x 7'-0'' DOOR W/ DOOR CLOSERA LEGEND (E) FIXED WINDOW1 Date: Drawn By: Dwg. No: Scale: Checked By: Title: Sheet No. . . AS SHOWN Jo b N a m e & A d d r e s s : MJ The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of NEW ASIA FSE, INC. These are available or limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this notice. Upon acceptance and use of this drawings, the Contractor agrees to review and inform Optima Group Inc. of any discrepancy or conflict prior to the preparation of without exception, shop drawings, templates, layouts, or any execution of any work related to the information contained on this document. Notice: 3400 N. PECK ROAD, EL MONTE, CA 91731 TEL: 626-575-5880 FAX: 626-575-5080 EMAIL:SALESNEWASIA@AOL.COM NEW ASIA FSE, INC. SCALE 1/4"=1'-0"1 13'-9" 10 ' - 1 " 13'-4" 10 ' - 8 " 16 ' - 7 " 11'-2" 21 ' - 8 " 18 ' - 6 " (E) WIC (E) WIF 14'-0" (E) STORAGE (E ) S T A I R R O O M 17 ' - 0 " 10'-0" 8' - 8 " 14'-4"21'-4" 8' - 8 " (E) HORSE SHOWER ROOM (EMPLOYEES ONLY) (E ) S T O R A G E (E M P L O Y E E S O N L Y ) (E) PUBLIC AREA (E) EXTERIOR RAMP N 2' - 6 " 1' - 1 1 " (N) WIC SCALE N.T.S SCALE N.T.S PANEL TO PANEL CONNECTION CEILING TO WALL CONNECTION- LAG 3 4 CORNER WALL TO WALL CONNECTION SCALE N.T.S WALL TO CONCRETE SLAB SCALE N.T.S CEILING TO WALL CONNECTION- LAG 1 2 FINISH SCHEDULE SCALE N.T.S. : No.Revision 2 3 4 5 6 Date 1 7 8 9 10 11 HEALTH10/08/22 BUILDING10/25/22 BUILDING12/20/22 BUILDING08/07/23 SA N T A A N I T A P A R K (A D D W A L K - I N C O O L E R ) 28 5 W . H U N T I N G T O N D R I V E , A R C A D I A , C A 9 1 0 0 7 --/--/---- PROPOSED FLOOR PLAN & FINISH SCHEDULE & WIC/ WIF DETAILS A-1.0 FINISH SCHEDULE NOTES 1) WALLS AND CEILINGS IN ALL AREAS EXCEPT OFFICE, DINING AREA SHALL BE DURABLE, SMOOTH, NONABSORBENT, AND EASILY WASHABLE WITH A LIGHT COLORED (LIGHT COLORED IS DEFINED AS HAVING A LIGHT REFLECTANCE VALUE OF 70% OR GREATER) FINISH. 2) ALL COUNTER SURFACES INCLUDING UNDERSIDE SHALL BE DURABLE, SMOOTH, NONABSORBENT, EASILY WASHABLE FINISH (MAY REQUIRE STAINLESS STEEL OR HIGH PRESSURE LAMINATE). 3) TILES IN RESTROOMS, SERVICE AREA AND KITCHEN SHALL BE DURABLE, SMOOTH, NONABSORBENT, EASILY WASHABLE FINISH. 4) FLOORING UNDER EQUIPMENT AND AT THE BASE COVES SHALL BE COMPLETELY SMOOTH. FLOOR SURFACES WHICH CONTAIN SLIP-RESISTANT AGENTS SHALL BE RESTRICTED TO TRAFFIC AREAS ONLY. 5) ALL EQUIPMENT SHALL BE EITHER EASILY MOVABLE (IE., ON CASTERS), ON MIN. 6 INCH ROUNDED METAL LEGS, OR SEALED TO MIN. 4 INCH SOLID MASONRY ISLAND WITH MIN. THREE-EIGHTHS INCH COVED RADIUS. 6) CONCRETE FLOOR MUST USE TOP-SET TYPE CERAMIC COVED BASE. 7) WATER RESISTANT WALLS (IE. FRP, STAINLESS STEEL, TILES) ARE REQUIRED BEHIND ALL SINKS AND DISHWASHERS. MATERIAL TO BE MIN. 4 FT. HIGH FOR LA COUNTY, MIN. 8 FT. HIGH FOR OTHER COUNTIES. ALL RESTROOM WALLS TO HAVE MOISTURE RESISTANT GYPSUM BOARD BACKING. 8) A MIN. 50-FOOT CANDLES OF LIGHT MEASURED 30" A.F.F. IN PREP AREAS; A MIN. 20-FOOT CANDLES OF LIGHT IN SAKE BAR, HANDWASHING AREAS, UTENSIL WASHING AREA, & RESTROOMS; A MIN. 10-FOOT CANDLES OF LIGHT IN STORAGE, JANITORIAL AREA & WALK-IN COOLER. MATERIAL NOTES: CEILING PANEL -- THE FOLLOWING CEILING PANELS ARE U.S.G #3270 VINYL ROCK OR NATIONAL GYPSUM GOLD BOND, GRIDSTONE GYPSUM CEILING PANELS. FLOOR COVERING -- THE FOLLOWING ARE APPROVED. TILES -- DALTILE OR EQUIVALENT. TOPSET (SLIM-FOOT) CERAMIC COVED BASE -- B&W TILE CO. #S-3619TN CONCRETE SEALER -- AMERITONE #7101, AQUA MIX® SEALER’S CHOICE® GOLD. INTERIOR FLOOR FINISHES SHALL COMPLY WITH SECTION 804 INTERIOR WALL AND CEILING FINISHES SHALL COMPLY WITH CBC 803.1, TABLE 803.13 AND TABLE 803.13 9 SEALED CONCRETE GALVINIZED METAL SHEET VINYL / VCT TILES SMOOTH FINISH PORCELAIN TILES FLOOR 6"X6" QUARRY TILES CARPET OR WOOD 6"H QUARRY TILES 4" VINYL/RUBBER 6"H WOOD BASE; PAINTED 6"H GALVINIZED METAL SMOOTH FINISH 3/8" RADIUS COVED BASE 6"H CERAMIC TILES (WHITE COLOR; TOPSET) 6"H CERAMIC / PORCELAIN TILES PAINT DRYWALL WALL TILES GALVINIZED METAL SEMI GLOSS WALL CEILING DRYWALL PAINT GALVINIZED METAL OPEN SEMI GLOSS LIGHT COLOR, SMOOTH, NON-ABSORBENT, EASILY CLEANABLE 2'X2' OR 2'X4' WASHABLE T-BAR CEILING VINYL TILES 2'X2' OR 2'X4' T-BAR CEILING TILES FRP ON WATER RESISTIVE DRYWALL 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 6 1 2 3 4 5 6 8 9 9 10 9 10 EPOXY 4" EPOXY 91111 MINIMUM OF 4-FEET HIGH FRP ABOVE THE COVE BASE. LIGHT COLOR, SMOOTH, NON-ABSORBENT, EASILY CLEANABLE STAINLESS STEEL FLASHING7 5 8 7 (E) WALK-IN COOLER 01 (E) WALK-IN FREEZER 5 5 6 6 4 8 9 4 8 9 1 8 4 8 8 8 7 7 FLOOR BASE WALL CEILINGROOM NAME (N) WALK-IN COOLER 02 56489188 7 12 15 16 PROPOSED FLOOR PLAN AA 1 120 V 1PH FC 280 V 3PH CU (E) F/S (E) F/S 3 NEW WALK-IN COOLER/FREEZER WALLS EXISTING WALK-IN COOLER/FREEZER WALLS EXISTING WALLS TO REMAIN JUNCTION BOX, CONNECT TO EQUIPMENT LEGEND (E) 3'-0'' x 7'-0'' DOOR W/ DOOR CLOSERA (E) FIXED WINDOW1 (E) 3'-0'' x 7'-0'' DOUBLE DOOR W/ DOOR CLOSERB B A MANUFACTURER: CUSTOM COOLER INC.MODEL NUMBER: CUSTOM MADELARR # 25690 3 Date: Drawn By: Dwg. No: Scale: Checked By: Title: Sheet No. . . AS SHOWN Jo b N a m e & A d d r e s s : MJ The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of NEW ASIA FSE, INC. These are available or limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this notice. Upon acceptance and use of this drawings, the Contractor agrees to review and inform Optima Group Inc. of any discrepancy or conflict prior to the preparation of without exception, shop drawings, templates, layouts, or any execution of any work related to the information contained on this document. Notice: 3400 N. PECK ROAD, EL MONTE, CA 91731 TEL: 626-575-5880 FAX: 626-575-5080 EMAIL:SALESNEWASIA@AOL.COM NEW ASIA FSE, INC. 12 15 11 No.Revision 2 3 4 5 6 Date 1 7 8 9 10 11 HEALTH10/08/22 BUILDING10/25/22 BUILDING12/20/22 BUILDING08/07/23 SA N T A A N I T A P A R K (A D D W A L K - I N C O O L E R ) 28 5 W . H U N T I N G T O N D R I V E , A R C A D I A , C A 9 1 0 0 7 --/--/----Date: Drawn By: Dwg. No: Scale: Checked By: Title: Sheet No. . . AS SHOWN Jo b N a m e & A d d r e s s : MJ The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of NEW ASIA FSE, INC. These are available or limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this notice. Upon acceptance and use of this drawings, the Contractor agrees to review and inform Optima Group Inc. of any discrepancy or conflict prior to the preparation of without exception, shop drawings, templates, layouts, or any execution of any work related to the information contained on this document. Notice: 3400 N. PECK ROAD, EL MONTE, CA 91731 TEL: 626-575-5880 FAX: 626-575-5080 EMAIL:SALESNEWASIA@AOL.COM NEW ASIA FSE, INC. TITLE 24 A-2.0 3