HomeMy WebLinkAbout40 E Huntington Dr - 2023 -15 6 4 4 M A R V I S T A S T . , WH I T T I E R , C A 9 0 6 0 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v i c t o r i f o n g @ g m a i l . c o m A-0 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 3. EXISTING BUILDING A FOOTPRINT 2,050 S.F. PROJECT DATA SHEET INDEX CONTACT VICINITY MAP 5. AP# 5773-013-022 7. OCCUPANCY TYPE: B, DENTAL OFFICE 4. TYPE OF CONSTRUCTION: V-B, NON SPRINKLER VICTOR FONG (626)318-3000 1. LOT SIZE: 7,300 S.F. 2. ZONING: CBD 8. FIRE SPRINKLER: NO. 2022 CALIF. MECHANICAL CODE 2022 CALIF. ELECTRICAL CODE 2022 CALIF. BUILDING CODE 2022 CALIF. PLUMBING CODE APPLICABLE CODE OWNER: HUNTINGTON HOLDING LIMITED (626) 201- 0336 2022 ENERGY CODE 6. NO. OF STORY: ONE A-0 PROJECT DATA A-2 PROPOSED FLOOR PLAN A-3 DETAILS/SECTION A-4 REFLECTIVE CEILING M-1 TO M-3 MECHANICAL PLAN E-1 ELECTRICAL PLAN P-1 TO P-2 PLUMBING PLAN. TITLE 24 COMPLAINCE SCOPE OF WORKS: 1. CONSTRUCT DENTAL OFFICE TI OF 1,200 SQ.FT. IN EXISTING RETAIL OFFICE BUILDING 2. (N) ACCESSIBLE RESTROOMS. 3. (N) HVAC FOR OFFICE SPACE. 4. (N) 200 AMP ELECTRICAL SUB PANEL.. 5. (N) PLUMBING WORK. 6. (E) ACCESSIBLE PARKING. 2022 CALIF. GREEN BUILDING STANDARD CODE DR. IRENE C. CHANG D.D.S., M.S. TENANT IMPROVEMENT PROJECT 40 E. HUNTINGTON DR., ARCADIA, CALIF. 91006 LI C . # 9 0 2 1 0 5 E. HUNTINGTON DR. SA N T A A N I T A 1S T A V E SITE YELLOW SEA CONSTRUCTION A-1.1 - 1.2 ADA STANDARDS A-1.3TO 1.5 CAL GREEN MANDATORY MEASURES A-5 T24 BUILDING ENVELOPE E-2TO 2.1 T24 LIGHTING P-3TO P-3.1 T24 WATER HEATER M-4 TO M-4.1 T24 MECHANICAL 9. OCCUPANCY LOAD PER TABLE 1004.5: 1200/150=8 E-1.2 LIGHTING & PHOTOMETRICS PLAN A-1.0 SITE PLAN STRUCTURE CALC. STC LAB TEST REPORT 1 BUILDING E-1.3 DENTAL EQUIPMENT CUT SHEETS 2 2 ELECT. NO PARK I N G VAN ℄ E.HUNTINGTON DR. 5773-013-022 5773-013-023 5773-013-021 #44 #40 B ACCESSIBLE 1/2" RADIUS WHITE REFLECTORIZED SIGN CONSTRUCTED OF PORCELAIN STEEL WITH BEADED TEXT BLUE A C PARKING VAN ACCESSIBLE LETTERING ON SIGN MUST BE A MINIMUM OF 1" IN. HEIGHT UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENCE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT MUST BE INCLUDED ON SIGN (MINIMUM OF 1" IN. HEIGHT) TOWED VEHICLES MAY BE RECLAIMED AT OR BY TELEPHONING OWNER'S EXPENSE. APPROPRIATE INFORMATION 80° MIN. FOR FREE STANDING 60" MIN. FOR WALL MOUNTED WALKING SURFACE TO TOP OF36" 36" 22" MIN. NOTE: WHEN A VEHICLE IS PROPERLY PARKED IN THE SPACE (CENTERED AT ENTRANCE TO STALL RECOMMENDED) SIGN TO BE CENTERED AT THE INTERIOR END OF PARKING SPACE. AREA OF SIGN TO BE A MIN. OF 70 SQ. IN. DESIGNATE FOR "VAN ACCESSIBLE" WHERE APPROPRIATE. EMBLEM MUST BE LOCATED IN STALL SO THAT IS VISIBLE BY A TRAFFIC ENFORCEMENT OFFICER OR EQUAL17" MIN. (Address) (Telephone Number) MINIMUM FINE $250 ACCESSIBLE PARKING SITE PLAN 1/8"=1' ℄ E . H U N T I N G T O N D R . ℄ A L L E Y 15 6 4 4 M A R V I S T A S T . , WH I T T I E R , C A 9 0 6 0 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v i c t o r i f o n g @ g m a i l . c o m A-1.0 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 VI C T O R I A M . C O M P A N Y PROPOSED DENTAL OFFICE (E) PROFESSIONAL OFFICE FIRST CABIN BAR DEJAVU SALON GENERAL PARKING NOTES Car and van parking spaces shall be 216 inches (5486 mm) long minimum. Car parking spaces shall be 108 inches (2743 mm) wide minimum and van parking spaces shall be 144 inches (3658 mm) wide minimum, shall be marked to define the width, and shall have an adjacent access aisle complying with Section 11B-502.3. Access aisles serving car and van parking spaces shall be 60 inches (1524 mm) wide minimum. 1 INTERNATIONAL ACCESSIBLE SYMBOL 2 PARKING ENTRANCE SIGN (A) 3 (E) CURB FACE 4 PROPERTY LINE TYP. 5 (E) 2HR MASONRY WALL @ ZERO SET BACK 6 (E) TRASH ENCLOSURE 7 (E) DRIVEWAY ENTRANCE 8 (E) LEVEL LANDING KEY NOTES 9 ADA SIGNS (C) TOTAL PARKING SPACE PROVIDED = 15 REQUIRED VAN ACCESSIBLE =1 PER CBC 11B 208 RE A R S E T B A C K 15 6 4 4 M A R V I S T A S T . , WH I T T I E R , C A 9 0 6 0 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v i c t o r i f o n g @ g m a i l . c o m A-1.1 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 LI C . # 9 0 2 1 0 5 15 6 4 4 M A R V I S T A S T . , WH I T T I E R , C A 9 0 6 0 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v i c t o r i f o n g @ g m a i l . c o m A-1.2 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 LI C . # 9 0 2 1 0 5 15 6 4 4 M A R V I S T A S T . , WH I T T I E R , C A 9 0 6 0 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v i c t o r i f o n g @ g m a i l . c o m A-1.3 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 LI C . # 9 0 2 1 0 5 15 6 4 4 M A R V I S T A S T . , WH I T T I E R , C A 9 0 6 0 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v i c t o r i f o n g @ g m a i l . c o m A-1.4 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 LI C . # 9 0 2 1 0 5 15 6 4 4 M A R V I S T A S T . , WH I T T I E R , C A 9 0 6 0 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v i c t o r i f o n g @ g m a i l . c o m A-1.5 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 LI C . # 9 0 2 1 0 5 15 6 4 4 M A R V I S T A S T . , WH I T T I E R , C A 9 0 6 0 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v i c t o r i f o n g @ g m a i l . c o m A-2 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 1. FLOOR PLAN 14" = 1' OFFICE LOBBY EQUIPMENT UNISEX RECEPTIONIST STERILE CBCT OPERATORY 4 2406.4.2 GLAZING ADJACENT TO DOORS. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE OF THE GLAZING IS WITHIN A 24-INCH (610 MM) ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524 MM) ABOVE THE WALKING SUR-FACE SHALL BE CONSIDERED A HAZARDOUS LOCATION. 2406.4.3 GLAZING IN WINDOWS. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING CONDITIONS SHALL BE CONSIDERED A HAZARDOUS LOCATION: A. THE EXPOSED AREA OF AN INDIVIDUAL PANE IS GREATER THAN 9 SQUARE FEET ; B. THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 18 INCHES ABOVE THE FLOOR; C. THE TOP EDGE OF THE GLAZING IS GREATER THAN 36 INCHES ABOVE THE FLOOR; AND D. ONE OR MORE WALKING SURFACE(S) ARE WITHIN 36 INCHES, MEASURED HORIZONTALLY AND IN A STRAIGHT LINE, OF THE PLANE OF THE GLAZING. 2. SAFTY GLAZING ARE IN COMPLIAINCE WITH CBC CHAPTER 2406.4.2 & 2406.4.3 1. INTERIOR WALL AND CIELING FINISHES COMPLY WITH SECTION 803.1.1 & TABLE 803.13 EXIT PASSAGE CLASS B = FLAME SPREAD INDEX 26-75; SMOKE DEVELOPED INDEX 0-450. REST OF THE BUILDING CLASS C= FLAME SPREAD INDEX 76-200; SMOKE DEVELOPED INDEX 0-450. GENERAL NOTES 3. DOORS SERVING AN OCCUPANT LOAD OF 50 OR MORE SHALL SWING IN THE DIRECTION OF EXIT TRAVEL. 4. LANDINGS OR FLOOR LEVEL AT DOORS SHALL NOT BE LESS THAN 1/2 INCH BELOW THE THRESHOLD. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 1 /4 INCH AT DOORWAYS SHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL TO TWO UNIT HORIZONTAL. 5. THE BOTTOM 10 INCHES OF ALL DOORS ON THE PUSH SIDE EXCEPT SLIDING SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE. 6. CORRIDOR WIDTH SHALL BE NOT LESS THAN 44" AND SHALL COMPLY WITH TABLE 1020.2. 7. DOORS OPENING INTO THE PATH OF EGRESS TRAVEL SHALL NOT REDUCE THE REQUIRED WIDTH TO LESS THAN ONE HALF DURING THE COURSE OF SWING. WHEN FULLY OPEN, THE DOOR SHALL NOT PROJECT MORE THAN 7" INTO THE REQUIRED WIDTH. 8. PROVIDE A LEVEL LANDING ON EACH SIDE OF A DOOR EXTENDING 60" ON DIRECTION OF DOOR SWING AND 48" IN OPPOSITE DIRECTION OF DOOR SWING, MEASURED WITH DOOR CLOSE 9. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE AT THE WALKING SURFACE. 10. EMERGENCY LIGHT SHALL PROVIDE AN INITIAL AVERAGE ILLUMINATION LEVEL OF AT LEAST 1 FOOT CANDLE BUT AT ANY POINT IT SHALL NOT BE LESS THAN 0.1 FOOD CANDLE ALONG THE PATH OF EGRESS TRAVEL AT THE FLOOR LEVEL. 11. AT THE END OF THE REQUIRED EMERGENCY SOURCE TIME DURATION, THE EMERGENCY LUMINARIES SHALL PROVIDE AN AVERAGE ILLUMINATION LEVEL OF LEAST 0.6 FOOT CANDLE BUT AT ANY POINT IT SHALL NOT BE LESS THAN 0.06 FOOT CANDLE ALONG THE PATH OF EGRESS AT FLOOR LEVEL. 12. WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS THAN 4 FEET (1219 MM) ABOVE THE FLOOR,AND EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED 13. INSULATION MUST BE INSTALLED IN DIRECT CONTACT WITH A CONTINUOUS ROOF OR CEILING INCLUDING BUT NOT LIMITED TO PLACING INSULATION EITHER ABOVE OR BELOW ROOF DECK OR ON TOP OF THE FINISHED CEILING. 14. WHEN INSULATION IS INSTALLED AT THE ROOF, FIXED VENTS OR OPENINGS TO THE OUTDOORS OR TO UNCONDITIONED SPACES SHALL BE INSTALLED AND THE SPACE BETWEEN THE CEILING AND THE ROOF IS EITHER DIRECTLY OR INDIRECTLY CONDITIONED SPACE AND SHALL NOT BE CONSIDERED AN ATTIC. 15. INSULATION SHOULD NOT BE PLACED ON TOP OF A SUSPENDED CEILING WITH REMOVABLE CEILING PANELS, EXCEPT FOR LIMITED APPLICATIONS. 16. CURTAINS, DRAPES AND OTHER DECORATIVE MATERIALS SUSPENDED FROM THE WALLS OR CEILINGS SHALL MEET THE FLAME SPREAD PROPAGATION PERFORMANCE CRITERIA OF NFPA 701 IN ACCORDANCE WITH SECTION 806.2 OR BE NONCOMBUSTIBLE. BUILDING CODE 806.1 30x48 30 x 4 8 30 x 4 8 30 x 4 8 30 x 4 8 101 102 104 105 103 109 108 106 110 107 111 112 HALL WAY OPERATORY 3 OPERATORY 2 OPERATORY 1 WALL LEGEND (E) CMU 2 HR WALL (E) PARTITION WALL (N) PARTITION WALL A3 1 A-3 5 A-3 5 008 008 008008 003 009 007 002 007 007 008 007 009 009 009 009 002 003 01 A3 2 A3 2 A3 2 A3 2 A3 2 A3 2 A3 2 A3 2 A3 2 A3 2 EXIT EXIT EXIT LI C . # 9 0 2 1 0 5 A3 8 D E N T A L X - R A Y M A C H I N E S M U S T BE REGISTERED WITH THE STATE DEPARTMENT OF PUBLIC HEALTH P E R C D C R E C O M M E N D A T I O N S , T H E L I C E N SED DENTIST AND X-RAY MACHINE REGISTRANT MUST KEEP DOSES RECEIVED BY P A T I E N T S A N D P E R S O N N E L B E L O W T H E ALLOWABLE LIMITS, MUST PROVIE RADIATION SAFETY RULES AND PROVIDE M O N I T O RING DEVICES. P R A C T I C I N G D E N T I S T M U S T COMPLY WITH OCCUPATIONAL EXPOSURE REQUIREMENTS O B S E R V E M A X I M U M P ERMISSIBLE DOSE EQUIVALENT (MPD) : - W H O L E B O D Y ( T O T A L E FFECTIVE DOSE EQUIVALENT) - 5 REM OR 0.05 Sv - S K I N A N D E X T R E M I T I E S (SHALLOW-DOSE EQUIVALENT) - 50 REM OR 0.5 Sv - l e n s o f t h e e y e (eye dose equivalent) - 15 rem or 0.15 Sv 005 005 007 A3 2 18. Examination, diagnostic and treatment rooms shall comply with Section 11B-805.4. 19. A 36-inch (914 mm) minimum wide clear space shall be provided along the full length exam tables, procedure tables, gurneys and lounge chairs. 20. All hand washing fixtures, lavatories and sinks shall comply with Section 11B-606. 21. Built-in cabinets, counters and work surfaces shall be accessible, including: patient wardrobes, nurse's stations, administrative centers, reception desks, medicine preparation areas, laboratory work stations, equipment consoles, clean and soiled utility cabinets, and storage areas; and shall comply with Sections 11B-225 and 11B-902. 17. A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided. A clear floor or ground space complying with Section 11B-305 shall be positioned for a parallel approach adjacent to the 36 inch (914 mm) minimum length of counter. Exception: Where the provided counter surface is less than 36 inches (914 mm) long, the entire counter surface shall be 34 inches (864 mm) high maximum above the finish floor. 001 001 A3 9 34" MAX. HT A.F.F. 1 1/2" WITH WASHER AS REQUIRED WITH 2-#8 SCREWS TO EA. STUD OR VERTICAL STUDS TO TOP TRACK NOTE: DO NOT SCREW DRYWALL 2 1/2" DEEP 20 GA. TOP TRACK CONT. WITH VERTICAL SLOTTED HOLES ROOFING EXISTING BUILT-UP WITH 3 #8 SCREWS @24" O.C. CONNECT TOP TRACK TO ROOF FRAMING BOTTOM TRACK WITH RAMSET (0.18"O x 1 1/2", ESR 1799) 1510 SHOT PINS AT 24" O.C. EXISTING CONC. SLAB 5/8" TYPE X GYP BOARD @ EACH SIDE OF 362S125 - 33 @ 16" O.C.(WALL HEIGHT TO 12' MAX) ICC ER 3064P (SCREWABLE) METAL STUDS PROV. R-13 INSULATION WHERE BUILDING ENVELOPE REQUIRED. (N) 2X BLOCKING IN BETWEEN (E) PURLIN @ 24" O.C. (N) R-38 AT ROOF DECK (N) 1/16" MASS LOADING VINYL WALL BLOKKER LITE EVA SOUND MENBRANE SECURED W/ 1/2" PAN HEAD SCREW 2 16" O.C. R-13 INSULATION ROOFING EXISTING ROOF STRUCTURE EXISTING BUILT-UP BOTTOM TRACK WITH RAMSET (0.18"O x 1 1/2", ESR 1799) 1510 SHOT PINS AT 24" EXISTING CONC. SLAB 5/8" TYPE X GYP BOARD @ EACH SIDE OF 362-125 - 33 @ 16" O.C. ICC ER 3064P (SCREWABLE) METAL STUDS 2 #8 SCREWS TYP. 362- 125 - 33 WALL BRACING @48" O.C. ALTERNATE DIRECTION 10 ' (N) 1/16" MASS LOADING VINYL WALL BLOKKER LITE EVA SOUND MENBRANE SECURED W/ 1/2" PAN HEAD SCREW 2 16" O.C. R-13 INSULATION U CHANNEL 250-U50-54 13' 6" MAX 3 5/8" 25 GA. MT. STUD 362-S125-33 3 5/8" TRACK 3 5/8" TRACK @ MID. SPAN 362-S125-33 @ 16" O.C. #8 FRAMING SCREW #8 FRAMING SCREW (ESR 3064 P) 5/8" TYPE "X" GYP. BD. EA. SIDE @ 16" O.C. 3 5/8" TRACK BLOCKING FULL LENGTH (ESR 3064 P) EACH FLANGEW/ #8 SCREWS ATTACH TRACK TO STUD @ CONC.SLAB TO STUD WITH #8 (#7 @ 18 MIL. STUDS) ATTACHED TRACK 43 MIL. UP TO 12'-0" PN'G.54 MIL. UP TO 16'-0" OPN'G. UP TO 10'-0" OPENING TRACK OPENING SCREW AT EACH 33 MIL. TYP. FLANGE CONT. TRACK W/.180" POWER DRIVEN SHOT PINS AT 16" O.C. U.N.O. AT SECTIONS (ESR-1799) OR APPROVED EQUAL SPAN 4'-0" 6'-0" 8'-0" 6'-0" 16'-0" 12'-0" INT. PARTITION 3 2 3 INT. PARTITION DEMISING WALL DEMISING WALL2 2 1 WALL TO MATCH KING STUDS 1 600S 162-43 DEMISING 800S 162-43 INT. 800S 162-54 (50 KSI) SIZE OF WALL SIZE OF WALL 362S 162-43 DEMISING HEADER SIZE 362S 162-33 INT. 600S 162-33 INT. 600S 162-43 DEMISING 362S 162-33 INT. SIZE OF WALL SIZE OF WALL SIZE OF WALL AND 33 MILS SIZE OF WALL DEMISING DEMISING 800S 162-68 (50 KSI) 800S 162-54 INT. AND 33 MILS AND 33 MILS AND 33 MILS AND 43 MILS AND 54 MILS HJ C 2'- 9 " G 3' - 4 " M A X . 17"-19" MIN 7", MAX 9" E 2 56" MIN. ELEVATION 24" MIN. 3'-6" MIN 7' - 0 " M I N . 32 " C L E A R 4'-0" MIN. E 2 1 E 5'-0" CLR. 30"x48" PLAN VIEW D JF 4' - 0 " B 3' - 4 " M A X . A E 9" M I N . 2'- 1 0 " M A X . 3' - 4 " M A X . 2' - 5 " M I N . E 1 MI N 1 7 " T O M A X 1 8 " UNDER LAVATORY. LAVATORY: WATER CLOSET: GRAB BAR: ELEVATION1. NO SHARP OR ABRASIVE SURFACES 2. LEVER FAUCET CONTROLS OPERABLE. WITH ONE HAND AND 5 LBS. MAXIMUM FORCE. 3. HOT WATER SUPPLY AND DRAIN PIPING INSULATED. 1. FLUSH CONTROL HANDLE ON WIDE SIDE WITH 3 LBS. MAXIMUM OPERATING FORCE. 3'- 0 " M I N . 18 " OF BARS TO WITHHOLD 250LB OF MIRROR PAPER TOWEL DISPENSER. TOILET PAPER HOLDER. SOAP DISPENSER. 1-1/2" CLEARANCE (FOR TANK TYPE TOILETS. 36" ABOVE FLOOR MAY BE ALLOWED IF TANKOBSTRUCTS PLACEMENT OF BARS). 2. PROVIDE SOLID BACKING FOR MOUNTING 3. NO ROTATION PERMITTED IF FITTINGS USED. 1. 1-1/4" TO 2" ROUND STEEL BARS WITH CEMENT, MARLITE ETC). SMOOTH, HARD, NONABSORBENT SURFACE (TILE, TOILET SEAT COVER DISPENSER. 12 " M I N . 12" MAX 19 " M I N . 48" MIN CLEAR 60 " M I N C L E A R 60" MIN CLEAR MIN 17" TO MAX 18" VERTICAL & HRIZONTAL FORCE. 15 6 4 4 M A R V I S T A S T . , WH I T T I E R , C A 9 0 6 0 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v i c t o r i f o n g @ g m a i l . c o m A-3 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 1. DEMISING WALL DETAILS NTS 2. PARTITION WALL DETAILS NTS 3. GUPSUM CEILING DETAILS NTS 4.BOX HEADER DETAILS NTS 5. CROSS SECTION 1 4"= 1' A3 2 LI C . # 9 0 2 1 0 5 THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER ACCESSIBLE SINK 8. ACCESSIBLE SINK NTS 30 x 4 8 30 x 4 8 SIGNAGE DOOR-MOUNTED 12" UNISEX WALL MOUNTED SIGNAGE TO BE LOCATED ON LATCH SIDE OF DOOR CLEAR OF DOOR-SWING. MOUNT AT 58" - 60" TO CENTERLINE OF SIGN FRON FLOOR. DOOR MOUNTED SIGNAGE (TYP.) NOTE: PICTOGRAMS AND/OR LETTERING ARE NOT REQUIRED ON DOOR-MOUNTED SIGNAGE. 58" to 60" 12" ALL GENDER 6. ROOF UNIT PLATFORM DETAILS NTS 7. ALL GENDER RESTROOM SIGN 9. ENLARGE RESTROOM 1/2"= 1' 15 6 4 4 M A R V I S T A S T . , WH I T T I E R , C A 9 0 6 0 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v i c t o r i f o n g @ g m a i l . c o m A-4 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 12 GAUGE SPLAY WIRES ALL 4 DIRECTION 90° APART @ 12' O.C., SECURED TO STRUCTURE (E) STRUCTURESPRING CLIP 12' O.C. 12 GAUGE VERTICAL HANGER WIRE @ 48" O.C. MAIN TEE SUSPENDED CEILING NOTES: USG Donn acoustical tile or lay-in panel ceilings (ESR-1222) in Seismic Design Categories D, E, and F shall be designed and installed in accordance with ASTM C635, ASTM C636, shall also comply with the following: 1. The width of the perimeter supporting closure angle or channel shall be not less than 2.0 in. Where perimeter supporting clips are used, they shall be qualified in accordance with approved test criteria. In each orthogonal horizontal direction, one end of the ceiling grid shall be attached to the closure angle or channel. The other end in each horizontal direction shall have a 0.75 in. clearance from the wall and shall rest upon and be free to slide on a closure angle or channel. 2. For ceiling areas exceeding 2,500 ft2, a seismic separation joint or full height partition that breaks the ceiling up into areas not exceeding 2,500 ft2 , each with a ratio of the long to short dimension less than or equal to 4, shall be provided unless structural analyses are performed of the ceiling bracing system for the prescribed seismic forces that demonstrate ceiling penetrations and closure angles or channels provide sufficient clearance to accommodate the anticipated lateral displacement. Each area shall be provided with closure angles or channelsand horizontal restraints or bracing. 3. Hangers for carrying channels or main runners 4 ft 0 in. on centers. 4. Each suspension wire shall not hang more than one in six out of plumb unless a countersloping wire or horizontal bracing is provided. Suspension wires should not press against ducts or pipes. 5. Wire hangers shall be a minimum of No. 12-gage galvanized, soft-annealed, mild steel wire. 6. Local kinks or bends shall not be made in hanger wires as a means of leveling carrying channels. 7. In installations where hanger wires are wrapped around carrying channels, the wire loops shall be tightly formed to prevent any vertical movement or rotation of the member within the loop. 8. Install main runners so that they are all level to within 1/4 in. in 10 ft Local kinks or bends shall not be made in hanger wires as a means of leveling main runners. 9. In installations where hanger wires are wrapped through or around main runners, the wire loops shall be tightly wrapped and sharply bent to prevent any vertical movement or rotation of the member within the loops. The wire must be wrapped around itself a minimum of three full turns (360° each) within a 3-in. length. For safety purposes, the bottom of the hanger wires shall either be cut close to the vertical portion of the wire or shall be bent upward parallel to the vertical portion of the hanger wire. 10. Install cross runners supported by either main runners or by other cross runners to within 1/32 in. [.8 mm] of the required center distances. This tolerance shall be noncumulative beyond 12 ft. 11. The exposed surfaces of the two intersecting runners shall lie within a vertical distance of .015 in. [.4 mm] of each other with the abutting (cross) member always above the continuous (main) member. 12. Join abutting sections of the main runner by means of suitable connection such as splices, interlocking ends, tab locks, pin locks, and so forth. A joint connection shall be judged suitable both before and after ceiling loads are imposed if the joint provides sufficient alignment so that the exposed surfaces of two abutting main runners lie within a vertical distance of .015 in. of each other. 13. There shall be no visually apparent angular displacement of the longitudinal axis of one runner with respect to the other. 14. Assembly devices shall provide sufficient spacing control so that horizontal gaps between exposed surfaces of either abutting or intersecting member shall not exceed .020 in. 15. Fixtures shall not be supported from main runners or cross runners if the weight of the fixture causes the total dead load to exceed the deflection capability of the ceiling suspension system. In such cases, the fixture load shall be support by supplemental hangers within 6 in. [150 mm] of each corner, or the fixture shall be separately supported. 3/8" min. - 3/4" max. 2" MIN ACOUSTICAL CEILING PANEL MAIN TEE OR CROSS TEE (FIELD CUT TO LENGTH) 12 GAUGE HANGER WIRE 8" MAX. POP RIVET 2" MIN. TEE 3/4" MIN. EXITEXIT EXIT EXIT EX I T LI C . # 9 0 2 1 0 5 15 6 4 4 M A R V I S T A S T . , WH I T T I E R , C A 9 0 6 0 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v i c t o r i f o n g @ g m a i l . c o m A-5 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 42 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 LI C . # 9 0 2 1 0 5 (E) OHPS (E) # 30 COPPER TO UFER & COLD WATER PIPE (N)200A 240V FUSE DISCONNECT M (E)200A 240V SINGLE PHASE METER BOX BY SIEMENS (N) PANEL A 200 AMP SINGLE LINE DIAGRAM NO SCALE FUSE RATED FOR 200K INTERRUPTING CURRENT AIC PROVIDE ARC FLASH WARNING LABELS FOR ALL ELECTRICAL EQUIPMENT. SERVICE ENTRANCE 10,000 AIC ALL CIRCUIT BREAKER TO BE RATED FOR 10K AIC MINIMUM # 3/0 COPPER W/ #6 GROUND 2 12" CONDUIT # 3/0 COPPER W/ #6 GROUND 2 12" CONDUIT PANEL A A-11,1320A 30AA-15,17 A-27,29 A-25 A-25 A-23A-25 A-23 A-21 A-19 A-21 A-19 A-18 A-18 A-20A-20 A-3 A-5 A-5 A-5 A-6 A-6 A-6 A-8 A-8 A-8 A-8 A-10 A-10 A-10 A-10 A-12 A-12 A-12 A-12 A-14 A-14 A-14 A-14 GFCI GFCI GFCI GFCI MMM A-12 A-12 A-12 A-14 GENERAL NOTES §110.9 LIGHTING CONTROLS AND COMPONENTS ALL LIGHTING CONTROL DEVICES AND SYSTEMS, BALLASTS, AND LUMINAIRES SHALL MEET THE APPLICABLE REQUIREMENTS OF §110.9. §130.0 GENERAL LUMINAIRE REQUIREMENTS (INDOOR) ALL LUMINAIRES SHALL BE FACTORY-LABELED PER §130.0(c). ENERGY MANAGEMENT CONTROL SYSTEMS (EMCS) SHALL MEET REQUIREMENTS OF §130.0(e). §130.1(a) INDIVIDUAL ROOM/AREA CONTROLS EACH ROOM AND AREA WITH FLOOR-TO-CEILING WALLS IN THIS BUILDING SHALL BE EQUIPPED WITH MANUAL ON AND OFF LIGHTING CONTROLS. EXCEPTION: UP TO 0.2 W/SF OF EGRESS LIGHTING MAY REMAIN ON IF: A. AREA(S) IS DESIGNATED FOR MEANS OF EGRESS ON THE PLANS AND SPECIFICATIONS B. CONTROLS FOR EGRESS LIGHTING ARE NOT ACCESSIBLE TO UNAUTHORIZED PERSONNEL. CONTROLS MUST BE READILY ACCESSIBLE. EXCEPTION: IN MALLS, ATRIA, AUDITORIUMS, RETAIL/WHOLESALE SALES AREAS, COMMERCIAL/INDUSTRIAL STORAGE AREAS, GENERAL COMMERCIAL/INDUSTRIAL WORK AREAS, CONVENTION CENTERS AND ARENAS LIGHTING CONTROL MUST BE LOCATED SO OPERATOR CAN SEE AREA(S) BEING LIT, OR AREA(S) ARE ANNUNCIATED. §130.1(a)4 SEPARATELY CONTROLLED LIGHTING SYSTEMS DISPLAY, TRACK, AND ORNAMENTAL LIGHTING SHALL BE SEPARATELY SWITCHED FROM GENERAL LIGHTING ON CIRCUITS THAT ARE ≤ 20 AMPS. §130.1(b) MULTI-LEVEL LIGHTING CONTROLS ALL ROOMS AND AREAS 100 SF OR GREATER AND MORE THAN 0.5 WATT PER SF OF LIGHTING LOAD WITH 2 OR MORE LUMINAIRES SHALL BE CONTROLLED WITH MULTI-LEVEL SWITCHING FOR UNIFORM REDUCTION OF LIGHTING WITHIN THE ROOM. CONTROL STEPS TO MEET REQUIREMENTS IN TABLE 130.1-A. EXCEPTION 1 TO §130.1(b): CLASSROOMS WITH A LIGHTING LOAD OF 0.7 W/SF OR LESS AND PUBLIC RESTROOMS SHALL HAVE ONE CONTROL STEP BETWEEN 30-70% OF FULL RATED POWER. EXCEPTION 3 TO §130.1(b): AREAS WHERE FULL OR PARTIAL OFF OCCUPANT SENSING CONTROLS ARE REQUIRED PER §130.1(c)6 (AISLE WAYS AND OPEN AREAS IN WAREHOUSES, LIBRARY BOOK STACK AISLES, LIGHTING INSTALLED IN CORRIDORS AND STAIRWELLS) AND AREAS WHERE PARTIAL OFF OCCUPANT SENSING CONTROLS ARE REQUIRED PER §130.1(c)6 (STAIRWELLS AND CORRIDORS PROVIDING ACCESS TO DWELLING UNITS AND GUEST ROOMS AND PARKING GARAGES/AREA AND LOADING UNLOADING AREAS WITH NO MORE THAN 500 WATTS PER CONTROLLED ZONE) §130.1(c)1,2 BUILDING LIGHTING SHUT-OFF CONTROLS EXCEPT WHERE OCCUPANT SENSORS ARE REQUIRED PER §130.1(c)5, PROVIDE OCCUPANT SENSORS, AUTOMATIC TIME-SWITCH CONTROL, OR OTHER AUTOMATIC SHUT-OFF CONTROL. PROVIDE SEPARATE CONTROLS FOR ENCLOSED SPACES UP TO 5,000 SF. EXCEPTION 3 TO §130.1(c)1: UP TO 0.1 W/SF FOR AREA IS DESIGNATED FOR EGRESS ON PLANS AND SPECIFICATIONS EXCEPTION 4 TO §130.1(c)1: ELECTRICAL ROOMS REQUIRED USE OF OCCUPANT SENSORS WHEN MULTI-LEVEL CONTROL IS REQUIRED PER 130.1(b) (ENCLOSED AREA ≥ 100 SF AND LIGHTING LOAD > 0.5 W/SF) PROVIDE VACANCY SENSOR OR PARTIAL-ON OCCUPANCY SENSOR. WHEN MULTI-LEVEL CONTROL IS NOT REQUIRED PER 130.1(b), PROVIDE OCCUPANT SENSOR, PARTIAL-ON OCCUPANT SENSOR, OR VACANCY SENSOR IN THE FOLLOWING SPACES: • OFFICES 250 SF OR SMALLER • MULTIPURPOSE ROOMS < 1,000 SF • CLASSROOMS OF ANY SIZE • CONFERENCE ROOMS OF ANY SIZE §130.2(c) CONTROLS FOR OUTDOOR LIGHTING ALL OUTDOOR LIGHTING SHALL BE OPERATED WITH CONTROLS HAVING THE FOLLOWING FEATURES: • AUTOMATICALLY TURNS OFF OUTDOOR LIGHTING WHEN DAYLIGHT IS AVAILABLE • INDEPENDENTLY CONTROLLED FROM OTHER ELECTRICAL LOADS BY AN AUTOMATIC SCHEDULING CONTROL • POLE LUMINAIRES WHERE BOTTOM OF THE LUMINAIRE IS NOT GREATER THAN 24 FT ABOVE GRADE AND IS GREATER THAN 75 WATTS EACH, NON-POLE LUMINAIRES GREATER THAN 30 WATTS EACH, AND LINEAR LIGHTING GREATER THAN 4 WATTS PER FOOT, SHALL MEET THE OCCUPANCY SENSOR AND PARTIAL LIGHTING POWER SECTIONS OF SECTION 130.2(c)3. • OUTDOOR SALES FRONTAGE LIGHTING SHALL MEET THE MOTION SENSOR OR PART-NIGHT OUTDOOR LIGHTING CONTROL REQUIREMENTS OF SECTION130.2(c)4. • BUILDING FACADE, ORNAMENTAL HARDSCAPE AND OUTDOOR DINING LUMINAIRES SHALL MEET AT LEAST ONE OF THE FOLLOWING: • A PART-NIGHT OUTDOOR LIGHTING CONTROL • AUTO-ON MOTION SENSORS THAT REDUCE LIGHTING POWER BY AT LEAST 40% BUT NO MORE THAN 90% • A CENTRALIZED TIME-BASED ZONE LIGHTING CONTROL CAPABLE OF AUTOMATICALLY REDUCING LIGHTING POWER BY AT LEAST 50% • OUTDOOR WALL MOUNTED LUMINAIRES (WALL PACKS) WHERE BOTTOM OF LUMINAIRE IS MOUNTED ≤ 24 FEET ABOVE THE GROUND SHALL COMPLY WITH §130.2(c)3 Individual Room/Area Controls Uniform Reduction for Individual Rooms Daylit Area Control Control of Exterior Lights Building Lighting Shut-off Override for Building Lighting Shut-off © Automatic Control Devices Certified Fluorescent Ballast and Luminaries Certified Tandem Wiring for Two-Lamp Ballast's © OC D 15 6 4 4 M A R V I S T A S T . , WH I T T I E R , C A 9 0 6 0 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v i c t o r i f o n g @ g m a i l . c o m E-1 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 CA L . S T A T E L I C . # 6 1 5 8 6 6 ET E L E C T R I C A L LEGEND ALL RECEPOTACLES AND PANELS SHALL MEET THE FOLLOWING CODE: IN PATIENT CARE SPACES CEc 517.13 (A)WIRING METHODS ALL BRANCH CIRCUITS SERVING PATIENT CARE SPACES SHALL BE PROVIDED WITH AN EFFECTIVE GROUND-FAULT CURRENT PATH BY INSTALLATION IN A METAL RACEWAY SYSTEM OR A CABLE HAVING A METALLIC ARMOR OR SHEATH ASSEMBLY. THE METAL RACEWAY SYSTEM, METALLIC CABLE ARMOR, OR SHEATH ASSEMBLY SHALL ITSELF QUALIFY AS AN EQUIPMENT GROUNDING CONDUCTOR IN ACCORDANCE WITH 250.118. (B) INSULATED EQUIPMENT GROUNDING CONDUCTORS AND INSULATED EQUIPMENT BONDING JUMPERS 1. GENERAL THE FOLLOWING SHALL BE DIRECTLY CONNECTED TO AN INSULATED COPPER EQUIPMENT GROUNDING CONDUCTOR THAT IS CLEARLY IDENTIFIED ALONG ITS ENTIRE LENGTH BY GREEN INSULATION AND INSTALLED WITH THE BRANCH CIRCUIT CONDUCTORS IN THE WIRING METHODS AS PROVIDED IN 517.13(A): THE GROUNDING TERMINALS OF ALL RECEPTACLES OTHER THAN ISOLATED GROUND RECEPTACLES METAL OUTLET BOXES, METAL DEVICE BOXES, OR METAL ENCLOSURES ALL NON-CURRENT-CARRYING CONDUCTIVE SURFACES OF FIXED ELECTRICAL EQUIPMENT LIKELY TO BECOME ENERGIZED THAT ARE SUBJECT TO PERSONAL CONTACT, OPERATING AT OVER 100 VOLTS EXCEPTION NO. 1: FOR OTHER THAN ISOLATED GROUND RECEPTACLES, AN INSULATED EQUIPMENT BONDING JUMPER THAT DIRECTLY CONNECTS TO THE EQUIPMENT GROUNDING CONDUCTOR IS PERMITTED TO CONNECT THE BOX AND RECEPTACLE(S) TO THE EQUIPMENT GROUNDING CONDUCTOR. ISOLATED GROUND RECEPTACLES SHALL BE CONNECTED IN ACCORDANCE WITH 517.16. EXCEPTION NO. 2: METAL FACEPLATES SHALL BE PERMITTED TO BE CONNECTED TO THE EQUIPMENT GROUNDING CONDUCTOR BY MEANS OF A METAL MOUNTING SCREW(S) SECURING THE FACEPLATE TO A GROUNDED OUTLET BOX OR GROUNDED WIRING DEVICE. EXCEPTION NO. 3: LUMINAIRES MORE THAN 2.3 M (71/2 FT) ABOVE THE FLOOR AND SWITCHES LOCATED OUTSIDE OF THE PATIENT CARE VICINITY SHALL BE PERMITTED TO BE CONNECTED TO AN EQUIPMENT GROUNDING RETURN PATH COMPLYING WITH 517.13(A) OR (B). (1)SIZING EQUIPMENT GROUNDING CONDUCTORS AND EQUIPMENT BONDING JUMPERS SHALL BE SIZED IN ACCORDANCE WITH 250.122. THE EQUIPMENT GROUNDING TERMINAL BUSES OF THE NORMAL AND ESSENTIAL BRANCH-CIRCUIT PANELBOARDS SERVING THE SAME INDIVIDUAL PATIENT CARE VICINITY SHALL BE CONNECTED TOGETHER WITH AN INSULATED CONTINUOUS COPPER CONDUCTOR NOT SMALLER THAN 10 AWG. WHERE TWO OR MORE PANELBOARDS SERVING THE SAME INDIVIDUAL PATIENT CARE VICINITY ARE SERVED FROM SEPARATE TRANSFER SWITCHES ON THE ESSENTIAL ELECTRICAL SYSTEM, THE EQUIPMENT GROUNDING TERMINAL BUSES OF THOSE PANELBOARDS SHALL BE CONNECTED TOGETHER WITH AN INSULATED CONTINUOUS COPPER CONDUCTOR NOT SMALLER THAN 10 AWG. THIS CONDUCTOR SHALL BE PERMITTED TO BE BROKEN IN ORDER TO TERMINATE ON THE EQUIPMENT GROUNDING TERMINAL BUS IN EACH PANELBOARD. 1 004 001 002 003 005 007 008 009 001 002 003 004 005 006 006 006 006 007 007 007 008 008 008 008 009 009 009 009 010 006 007 UNIT 44 (E) PROFESSIONAL OFFICE 010 1 30A PATIENT CARE SPACES ** ** (D) Patient Care Vicinity Grounding and Bonding (Optional) A patient care vicinity shall be permitted to have a patient equipment grounding point. The patient equipment grounding point, where supplied, shall be permitted to contain one or more listed grounding and bonding jacks. An equipment bonding jumper not smaller than 10 AWG shall be used to connect the grounding terminal of all grounding-type receptacles to the patient equipment grounding point. The bonding conductor shall be permitted to be arranged centrically or looped as convenient. Informational Note: Where there is no patient equipment grounding point, it is important that the distance between the reference grounding point and the patient care vicinity be as short as possible to minimize any potential differences. (E) Equipment Grounding and Bonding Where a grounded electrical distribution system is used and metal feeder raceway or Type MC or MI cable that qualifies as an equipment grounding conductor in accordance with 250.118 is installed, grounding of enclosures and equipment, such as panelboards, switchboards, and switchgear, shall be ensured by one of the following bonding means at each termination or junction point of the metal raceway or Type MC or MI cable: A grounding bushing and a continuous copper bonding jumper, sized in accordance with 250.122, with the bonding jumper connected to the junction enclosure or the ground bus of the panel Connection of feeder raceways or Type MC or MI cable to threaded hubs or bosses on terminating enclosures Other approved devices such as bonding-type locknuts or bushings. Standard locknuts shall not be used for bonding. 2 2 2 Equipment grounding. To provide each branch circuit serving a patient care area with an effective ground-fault current path is to install those circuits in metal raceway.in a cable having a metallic armor or sheath that qualifies as an equipment grounding conductor. No PVC is allowed in this area. Hospital grade receptacles to be used within patient space OC OC OC OC OC OC OC OC OC OC D D D D D DD D D OC OC A-4 A-4 A-2A-2 A-2 A-2 A-2 A-4 A-4 A-4 A-4 A-2 EXIT EXITEXIT A-15 A-15 A-15 A-15 15 6 4 4 M A R V I S T A S T . , WH I T T I E R , C A 9 0 6 0 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v i c t o r i f o n g @ g m a i l . c o m E-1.2 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 CA L . S T A T E L I C . # 6 1 5 8 6 6 ET E L E C T R I C A L EXIT EXITEXIT EXITEXIT 1 15 6 4 4 M A R V I S T A S T . , WH I T T I E R , C A 9 0 6 0 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v i c t o r i f o n g @ g m a i l . c o m E-1.3 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 CA L . S T A T E L I C . # 6 1 5 8 6 6 ET E L E C T R I C A L 15 6 4 4 M A R V I S T A S T . , WH I T T I E R , C A 9 0 6 0 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v i c t o r i f o n g @ g m a i l . c o m E-2 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 CA L . S T A T E L I C . # 6 1 5 8 6 6 ET E L E C T R I C A L 15 6 4 4 M A R V I S T A S T . , WH I T T I E R , C A 9 0 6 0 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v i c t o r i f o n g @ g m a i l . c o m E-2.1 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 CA L . S T A T E L I C . # 6 1 5 8 6 6 ET E L E C T R I C A L 31 2 9 S . H a c i e n d a B l v d . , # 3 9 3 Ha c i e n d a H e i g h t s , C A 9 1 7 4 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v f o n g @ c h a r t e r . n e t CO M M E R C I A L I N D U S T R I A L CA L . S T A T E L I C . # B 9 0 2 1 0 5 YE L L O W S E A CO N S T R U C T I O N C O . M-1 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 15 6 4 4 M A R V I S T A S T . , WH I T T I E R , C A 9 0 6 0 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v i c t o r i f o n g @ g m a i l . c o m M-2 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 s 140 s 140 s 125 s 125 s 130 s s 120 s R 8" 8" 10" 8" 12" 14" 10" 8" 8" 12" R R 14"12" 8" 8" 8" 12" 120 120 4" VTR E 110 KD12 KD12 KD9 CA L . S T A T E L I C . # B 9 0 2 1 0 5 YE L L O W S E A CO N S T R U C T I O N C O . MECHANICAL FLOOR PLAN 14"=1' 60 CFM 3" OSA DUCT THRU ROOF W/ WHEATHER CAP & SCREEN 45 CFM 3" OSA DUCT THRU ROOF W/ WHEATHER CAP & SCREEN CONDENSATE DRAIN DETAILSCALE NONE 3T-STAT MTG HT. 5NONE SCALEAIR DISTRIBUTION DETAIL SCALE NONE 4SCALE NONE 2 -- CEILING MOUNTED EXHAUST FAN OUTDOOR EQUIPMENT PAD DETAILSCALE NONE 1 6NONE SCALE 7NONE SCALECONTROL DIAGRAMS 31 2 9 S . H a c i e n d a B l v d . , # 3 9 3 Ha c i e n d a H e i g h t s , C A 9 1 7 4 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v f o n g @ c h a r t e r . n e t CO M M E R C I A L I N D U S T R I A L M-3 HP - DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 LI C . # 9 0 2 1 0 5 -- FAN COIL MOUNTING DETAIL 6. ROOF UNIT PLATFORM DETAILS NTS 8NONE SCALE 31 2 9 S . H a c i e n d a B l v d . , # 3 9 3 Ha c i e n d a H e i g h t s , C A 9 1 7 4 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v f o n g @ c h a r t e r . n e t CO M M E R C I A L I N D U S T R I A L M-4 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 LI C . # 9 0 2 1 0 5 31 2 9 S . H a c i e n d a B l v d . , # 3 9 3 Ha c i e n d a H e i g h t s , C A 9 1 7 4 5 te l : ( 6 2 6 ) 3 1 8 - 3 0 0 0 fa x : ( 5 6 2 ) 6 9 8 - 6 6 6 6 e- m a i l : v f o n g @ c h a r t e r . n e t CO M M E R C I A L I N D U S T R I A L M-4.1 DR . I R E N E C H A N G D . D . S . , M . S . I N C . 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 9 1 0 0 6 LI C . # 9 0 2 1 0 5 VTR SANITARY WASTE SANITARY VENT DOMESTIC COLD WATER DOMESTIC HAT WATER GAS LINE FLOOR CLEAN OUT WALL CLEAN OUT SHUT OFF VALVE GAS SHUT OFF VALVE POINT OF CONNECTION FLOOR DRAIN VENT TO ROOF WATER CLOSET WATER HEATER FLOOR SINK WC WH TP LAV TRAP PRIMER LAVATORY BACK FLOW DEVISE PLUMBING LEGEND SERVICE ABOVE GROUNDBELOW GROUND HOT & COLD WATER SANITARY WASTE SANITARY VENT HOT TEMPER COLD DRAWN COPPER TYPE "K" CAST IRON / ABS SCHEDULE 40 HOT TEMPER COLD DRAWN COPPER TYPE "L"APOLLO PEX * CAST IRON / ABS SCHEDULE 40 CAST IRON / ABS SCHEDULE 40 CAST IRON / ABS SCHEDULE 40 PIPE MATERIALS SCHEDULE TE N A N T I M P R O V E M E N T 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . 1) Pipe Insulation Wall Thickness. Hot water pipe insulation shall have a minimum wall thickness of not less than the diameter of the pipe for a pipe up to 2 inches (50 mm) in diameter. Insulation wall thickness shall be not less than 2 inches (51 mm) for a pipe of 2 inches (50 mm) or more in diameter. 2) Disinfection of Potable Water System. New or repaired potable water systems shall be disinfected prior to use where required by the Authority Having Jurisdiction. Prior to utilization of newly constructed or altered potable water piping systems, all affected potable water piping shall be disinfected using procedures prescribed in California Plumbing Code Sections 609.9(1) through 609.9(4). The method to be followed shall be that prescribed by the Health Authority or, in case no method is prescribed by it, the following: A) The pipe system shall be flushed with clean, potable water until potable water appears at the points of outlet. B) The system or parts thereof shall be filled with a water-chlorine solution containing not less than 50 parts per million of chlorine, and the system or part thereof shall be valved-off and allowed to stand for 24 hours; or, the system or part thereof shall be filled with a water-chlorine solution containing not less than 200 parts per million of chlorine and allowed to stand for 3 hours. C) Following the allowed standing time, the system shall be flushed with clean, potable water until the chlorine residual in the water coming from the system does not exceed the chlorine residual in the flushing water. D) The procedure shall be repeated where it is shown by bacteriological examination made by an approved agency that contamination persists in the system. 3) Vent Pipe Rise. Unless prohibited by structural conditions, each vent shall rise vertically to a point not less than 6 inches (152 mm) above the flood-level rim of the fixture served before offsetting horizontally, and where two or more vent pipes converge, each such vent pipe shall rise to a point not less than 6 inches (152 mm) in height above the flood-level rim of the plumbing fixture it serves before being connected to any other vent. Vents less than 6 inches (152 mm) above the flood-level rim of the fixture shall be installed with approved drainage fittings, material, and grade to the drain. 4) Exposed pipes and Surfaces. Water supply and drain pipes under accessible lavatories and sinks shall be insulated or otherwise be configured to protect against contact. Protectors, insulators, or both shall comply with ASME A112.18.9. 5) WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the following: 5.303.3.1 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank-type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Tank-Type toilets. Note: The effective flush volume of dual flush toilets is defined as the composite, average flush volume of two reduced flushes and one full flush. 5.303.3.2 Urinals. 5.303.3.2.1 Wall-mounted Urinals. The effective flush volume of wall-mounted urinals shall not exceed 0.125 gallons per flush. C-36 961164 JV C O N S T R U C T I O N CO M M E R C I A L I N D U S T R I A L P1 CA . S T . L I C 9 6 1 1 6 4 GENERAL NOTES 6) PIPING SUPPORT TO COMPLY WITH TABLE 313.3 & 313.6. 7) APPOLO PEX SIZING CHART & INSTALLATION MANUAL IS ATTACHED * 1) ALL UNDERGRADE PIPES & CONDUITS SHALL BE 12" MINIMUM SEPARATION BETWEEN AIR & VACUUM LINE. 2) ALL PLUMBING TRENCHES SHALL BE 12" MIN. IN DEPTH. 3) ALL MEDICAL GAS & VACUUM PIPING SHALL COMPL WITH SEC. 1304.0 OF CPC 2021 VACUUM & COMPRESSED AIR LINE 14" = 1' TO (E) WATER METER HOT & COLD WATER 14" = 1' FS WC TP 2"VTR 2"VTR WASTE & VENT 14" = 1' P-2 DR. IRENE CHANG D.D.S., M.S. INC. 40 E. HUNTINGTON DR., ARCADIA, CALIF. 91006 JV CONSTRUCTION COMMERCIAL INDUSTRIAL CA. ST. LIC 961164 C-36 961164 15644 MAR VISTA ST., WHITTIER, CA 90605 tel: (626) 318-3000 fax: (562) 698-6666 e-mail: victorifong@gmail.com PLUMBING FLOOR PLAN UR LAV. KS HS FS WC UR LAV. KS HS TE N A N T I M P R O V E M E N T 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . C-36 961164 JV C O N S T R U C T I O N CO M M E R C I A L I N D U S T R I A L P3 CA . S T . L I C 9 6 1 1 6 4 TE N A N T I M P R O V E M E N T 40 E . H U N T I N G T O N D R . , AR C A D I A , C A L I F . C-36 961164 JV C O N S T R U C T I O N CO M M E R C I A L I N D U S T R I A L P3.1 CA . S T . L I C 9 6 1 1 6 4 BUILDING ENERGY ANALYSIS REPORT PROJECT: Project Designer: Report Prepared by: Job Number: Date: The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2022 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC – www.energysoft.com. 42 E. Huntington Dr. Dentist Office TI Arcadia, CA 91789Arcadia, CA 91006 16776 Bernardo Center Dr., Suite 203 Hensel Consulting Engineers, Inc. David Hensel, PE San Diego, CA 92128 (619) 665-3259 2312423431 3/15/20239/28/2023 TABLE OF CONTENTS Cover Page Table of Contents 1 2 Form NRCC-LTI-E Indoor LightingForm NRCC-LTI-E Prescriptive Indoor Lighting Compliance 8 Form NRCC-ENV-E Prescriptive Envelope Compliance 3 Form NRCC-LTI-E Indoor LightingForm NRCC-PLB-E Prescriptive Domestic Water Heating Systems Compliance 29 Form NRCC-MCH-E Prescriptive Mechanical Compliance 17 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0002 Report Generated: 2023-09-27 08:34:32 STATE OF CALIFORNIA Envelope Component Approach CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-ENV-E This document is used to demonstrate compliance with mandatory requirements in 110.8(g) and 120.7(b)/ 160.1 for newly constructed nonresidential, hotel/ motel, multifamily and mixed-use buildings, and 141.0(b)1/ 180.2 for alterations, related to roof, wall and floor assemblies. It is also used to demonstrate compliance with prescriptive requirements in 140.3/ 170.2 for newly constructed buildings, and 141.0/ 180.1/ 180.2 for additions and alterations, related to roof, wall, floor, door, fenestration and daylighting requirements. Project Name: Dentist Office TI Report Page: (Page 1 of 5) Project Address: Date Prepared: 2023-09-27T11:34:29-04:00 A. GENERAL INFORMATION 01 Project Location (city)Arcadia 05 # of Stories (Habitable Above Grade)1 02 Zipcode 91006 06 Total Conditioned Floor Area (ft2)1019 03 Climate Zone 9 07 Total Unconditioned Floor Area (ft2)0 04 Occupancy Types Within Project: (select all that apply): If one occupancy constitutes >= 80% of the conditioned floor area, the entire building envelope may be designed to comply with the provisions of that occupancy per 100.0(f). 08 Project includes unconditioned enclosed space(s) > 5,000 ft2 under a roof with a ceiling height of at least 15 ft.1 ● Medical Clinic 1 FOOTNOTE: Enclosed spaces > 5,000 ft2 directly under roof with ceiling height > 15 ft in climate zones 2 through 15 are required to meet the minimum daylighting requirements defined in 140.3(c)/ 170.2(b). Compliance with 140.3(c)/ 170.2(b) is documented in Table L. This is the only prescriptive requirement which applies to unconditioned spaces. B. PROJECT SCOPE This table specifies project envelope components within the permit application demonstrating compliance using the prescriptive paths outlined in 140.3/ 170.2 and 141.0(a)1/ 180.1 and 141.0(b)1 and 2/ 180.2 for additions and alterations. My project consists of (check all that apply)Component Types 01 02 New Construction or Newly Conditioned Space Roof Walls Exterior Opaque Doors One or more enclosed spaces > 5,000 ft2 directly under roof with ceiling height > 15ft Floors Fenestration/ Glazed Doors1 Addition of conditioned space Roof Walls Exterior Opaque DoorsOne or more enclosed spaces > 5,000 ft2 directly under roof with ceiling height > 15ft Addition is <=700 ft2 Floors Fenestration/ Glazed Doors1 Addition is >700 ft2 Alteration of conditioned space Roof Assembly Walls One or more enclosed spaces > 5,000 ft2 directly under roof with ceiling height > 15ft and lighting system installed for the first time Roofing Material2 Floors Fenestration HuntingtonE.Dr.42 STATE OF CALIFORNIA Envelope Component Approach CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-ENV-E Project Name: Dentist Office TI Report Page: (Page 2 of 5) Date Prepared: 2023-09-27T11:34:29-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0002 Report Generated: 2023-09-27 08:34:32 B. PROJECT SCOPE 1FOOTNOTE: Doors that are more than 25% glass in area are considered Glazed Doors and should be documented on table K with fenestration. 2Roof recovers and replacements must also check "Roof Assembly" box and document compliance with insulation requirements in Table F. Roof recoats may document compliance with roof material only in Table G. C. COMPLIANCE RESULTS Results in this table are automatically calculated from data input and calculations in Tables F through L. Note: If any cell on this table says "COMPLIES with Exceptional Conditions" refer to Table D. Exceptional Conditions for guidance or see the applicable table referenced below. Opaque Envelope Components Fenestration Daylighting Spaces > 5,000ft2 Compliance ResultsRoof Assembly Roofing Materials Walls Floors Doors 01 02 03 04 05 06 07 08 (See Table F)(See Table G)(See Table H)(See Table I)(See Table J)(See Table K)(See Table L)COMPLIESYes D. EXCEPTIONAL CONDITIONS This table is auto-filled with uneditable comments because of selections made or data entered in tables throughout the form. E. ADDITIONAL REMARKS This table includes remarks made by the permit applicant to the Authority Having Jurisdiction. F. ROOF ASSEMBLY SCHEDULE This table demonstrates compliance for prescriptive roof assembly requirements in 140.3(a)1B/ 170.2(a)1B for new construction, 141.0(a)/ 180.1 for additions, or 141.0(b)2Biii/ 180.2 for alterations, 01 Indicate roof types included in the project:Framed Framed- Multifamily SIPS Span Deck & Concrete Metal Panels Metal Building Framed Roof Assemblies 01 Include Framed Roof Assemblies in Area-Weighted Average U-factor Calculation1 STATE OF CALIFORNIA Envelope Component Approach CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-ENV-E Project Name: Dentist Office TI Report Page: (Page 3 of 5) Date Prepared: 2023-09-27T11:34:29-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0002 Report Generated: 2023-09-27 08:34:32 F. ROOF ASSEMBLY SCHEDULE Framed Roof Assemblies 02 03 04 05 06 Tag/Plan Detail ID Name/Description Status Exception to Roof Insulation Requirements in §141.0(b)2Biii  (Alts. Only)Occupancy Type Altered R-38 Roof Altered R-38 Roof Altered No exception applies Nonresidential/ Relocatable 1 CZ 07 08 09 10 11 12 13 14 15 16 Tag/Plan Detail ID How Design U-factor was determined Roof Type & Frame Material Frame Spacing Depth Cavity Insulation per Design2 Continuous Insulation per Design2 Thermal Performance Unit Required Thermal Performance3 U-factor per Design Net Area4 ft2 Altered R-38 Roof JA4 Tables Rafter- Wood 2x12 R-38 None U-factor 0.037 per JA4 0.028 per Software/ Other 1FOOTNOTES: If any individual assembly is non-compliant, assemblies may show compliance using an area-weighted calculation. Metal building roofs may not be combined with other roof types. The area-weighted compliance option is not available for alterations demonstrating compliance with R-values in Table 141.0-C. 2 For alterations using U-factor as the Thermal Performance Unit, at least R-10 insulation must be above deck. 3 If "R-value" is shown in cell 13 as the Thermal Performance Unit, the R-value shown here is for continuous insulation per Table 141.0-C. 4 Roof area minus any fenestration/ skylight area G. RATED ROOFING MATERIAL (COOL ROOF) This section does not apply to this project. H. WALL ASSEMBLY SCHEDULE This section does not apply to this project. I. FLOOR ASSEMBLY SCHEDULE This section does not apply to this project. STATE OF CALIFORNIA Envelope Component Approach CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-ENV-E Project Name: Dentist Office TI Report Page: (Page 4 of 5) Date Prepared: 2023-09-27T11:34:29-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0002 Report Generated: 2023-09-27 08:34:32 J. EXTERIOR DOOR SCHEDULE This section does not apply to this project. K. FENESTRATION AND GLAZED DOOR SCHEDULE This section does not apply to this project. L. DAYLIGHT IN LARGE ENCLOSED SPACES This section does not apply to this project. M. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION Selections have been made based on information provided in this document. If any selection have been changed by the permit applicant, an explanation should be included in Table E Additional Remarks. These documents must be provided to the building inspector during construction and can be found online Form/Title NRCI-ENV-01-E - Must be submitted for all buildings N. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE There are no NRCA forms required for this project. O. DECLARATION OF REQUIRED CERTIFICATES OF VERIFICATION There are no forms required for this project. STATE OF CALIFORNIA Envelope Component Approach CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-ENV-E Project Name: Dentist Office TI Report Page: (Page 5 of 5) Project Address: Date Prepared: 2023-09-27T11:34:29-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0002 Report Generated: 2023-09-27 08:34:32 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (if applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Compliance is true and correct. 2.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer) 3.The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5.I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone: David Hensel, PE Hensel Consulting Engineers, Inc. 16776 Bernardo Center Dr., Suite 203 San Diego CA 92128 9/28/2023 M32901 (619) 665-3259 42 E. Huntington Dr. Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0004 Report Generated: 2023-09-27 09:10:38 STATE OF CALIFORNIA Indoor Lighting CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-E This document is used to demonstrate compliance with requirements in 110.9, 110.12(c), 130.0, 130.1, 140.6 and 141.0(b)2 for indoor lighting scopes using the prescriptive path for nonresidential and hotel/motel occupancies. It is also used to document compliance with requirements in 160.5, 170.2(e) and 180.2(b)4 for indoor lighting scopes using the prescriptive path for multifamily occupancies. Multifamily includes dormitory and senior living facilities. Project Name: Dentist Office TI Report Page: (Page 1 of 9) Project Address: Date Prepared: 2023-09-27T12:10:35-04:00 A. GENERAL INFORMATION 01 Project Location (city)Arcadia 04 Total Conditioned Floor Area (ft2)1,019 02 Climate Zone 9 05 Total Unconditioned Floor Area (ft2)0 03 Occupancy Types Within Project (select all that apply):06 # of Stories (Habitable Above Grade)1 ● Medical Clinic B. PROJECT SCOPE This table includes any lighting systems that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in 140.6 / 170.2(e) or 141.0(b)2 / 180.2(b)4 for alterations. Scope of Work Conditioned Spaces Unconditioned Spaces 01 02 03 04 05 My Project Consists of (check all that apply):Calculation Method Area (ft2)Calculation Method Area (ft2) New Lighting System Area Category Method 1019 N/A 0 New Lighting System - Parking Garage N/A 0 N/A 0 Total Area of Work (ft2)1019 42 E. Huntington Dr. STATE OF CALIFORNIA Indoor Lighting CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-E Project Name: Dentist Office TI Report Page: (Page 2 of 9) Date Prepared: 2023-09-27T12:10:35-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0004 Report Generated: 2023-09-27 09:10:38 C. COMPLIANCE RESULTS If any cell on this table says "DOES NOT COMPLY" or "COMPLIES with Exceptional Conditions" refer to Table D. for guidance. Lighting in conditioned and unconditioned spaces must not be combined for compliance per 140.6(b)1 / 170.2(e) Allowed Lighting Power per 140.6(b) / 170.2(e) (Watts) ≥ Adjusted Lighting Power per 140.6(a) / 170.2(e) (Watts)Compliance Results 01 02 03 04 = 05 06 07 = 08 09 Complete Building 140.6(c)1 Area Category 140.6(c)2 / 170.2(e)4 Area Category Additional 140.6(c)2G / 170.2(e)4Av ( +) Tailored 140.6(c)3 / 170.2(e)4B ( +) Total Allowed (Watts) Total Designed (Watts) Adjustments Total Adjusted (Watts) *Includes Adjustments 05 must be >= 08 140.6 / 170.2(e) PAF Lighting Control Credits 140.6(a)2 / 170.2(e)1B (-) (See Table I)(See Table I)(See Table J)(See Table K)(See Table F)(See Table P) Conditioned 792 =792 ≥745.5 =745.5 COMPLIES Unconditioned =≥= Controls Compliance (See Table H for Details)COMPLIES Rated Power Reduction Compliance (See Table Q for Details)  D. EXCEPTIONAL CONDITIONS This table is auto-filled with uneditable comments because of selections made or data entered in tables throughout the form. E. ADDITIONAL REMARKS This table includes remarks made by the permit applicant to the Authority Having Jurisdiction. STATE OF CALIFORNIA Indoor Lighting CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-E Project Name: Dentist Office TI Report Page: (Page 3 of 9) Date Prepared: 2023-09-27T12:10:35-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0004 Report Generated: 2023-09-27 09:10:38 F. INDOOR LIGHTING FIXTURE SCHEDULE This table includes all planned permanent and portable lighting other than dwelling unit/ hotel/ motel room lighting. Multifamily dwelling unit and hotel/motel room lighting is documented in Table T. If using Table T to document lighting in multifamily common use areas providing shared provisions for living, eating, cooking or sanitation, those luminaires are not included here. Designed Wattage: Conditioned Spaces 01 02 03 04 05 06 07 08 09 10 Name or Item Tag Complete Luminaire Description Modular (Track) Fixture Small Aperture & Color Change1 Watts per luminaire2 How is Wattage determined Total Number of Luminaires Excluded per 140.6(a)3 / 170.2(e)2C Design Watts Field Inspector Pass Fail 2x2 LED Lithonia 2x2 Troffer LED No NA 30 Mfr. Spec 22 No 660 2x4 LED Lithonia 2GTL4 4400LM LP835 No NA 34.5 Mfr. Spec 1 No 34.5 Recessed LED Halo ML56 900 No NA 10.19 Mfr. Spec 5 No 51 Total Designed Watts: CONDITIONED SPACES 745.5 1FOOTNOTE: Design Watts for small aperture and color changing luminaires which qualify per 140.6(a)4B / 170.2(e)2D is adjusted to be 75% /80% of their rated wattage. Table F automatically makes this adjustment, the permit applicant should enter full rated wattage in column 05. 2Authority Having Jurisdiction may ask for Luminaire cut sheets to confirm wattage used for compliance per 130.0(c) / 160.5(b). Wattage used must be the maximum rated for the luminaire, not the lamp. G. MODULAR LIGHTING SYSTEMS This section does not apply to this project. H. INDOOR LIGHTING CONTROLS (Not including PAFs) This table includes lighting controls for conditioned and unconditioned spaces. Building Level Controls 01 02 03 Mandatory Demand Response 110.12(c)Shut-off controls 130.1(c) / 160.5(b)4C Field Inspector Pass Fail NA < 4,000W subject to multilevel See Area/Space Level Controls STATE OF CALIFORNIA Indoor Lighting CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-E Project Name: Dentist Office TI Report Page: (Page 4 of 9) Date Prepared: 2023-09-27T12:10:35-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0004 Report Generated: 2023-09-27 09:10:38 H. INDOOR LIGHTING CONTROLS (Not including PAFs) Area Level Controls 04 05 06 07 08 09 10 11 12 Area Description Complete Building or Area Category Primary Function Area Manual Area Controls 130.1(a) / 160.5(b)4A Multi-Level Controls 130.1(b) / 160.5(b)4B Shut-Off Controls 130.1(c) // 160.5(b)4C Primary/Sky lit Daylighting 130.1(d) / 160.5(b)4D Secondary Daylighting 130.1(d) / 160.5(b)4D Interlocked Systems 140.6(a)1/ 170.2(e)2A Field Inspector Pass Fail 101-Lobby Main Entry Lobby Readily Accessible Dimmer Auto. Time Switch NA: Not daylit zone NA: Not daylit zone No 102-Equipment Electrical Mechancial Telephone Room Readily Accessible NA: Enclosed area <100SF Auto. Time Switch NA: Not daylit zone NA: Not daylit zone No 103-Office Office ( <=250 square feet)Readily Accessible NA: Enclosed area <100SF Auto. Time Switch NA: Not daylit zone NA: Not daylit zone No 104-Unisex Restroom Restroom Readily Accessible NA: Restrooms Auto. Time Switch NA: Not daylit zone NA: Not daylit zone No 105-Reception Lounge Readily Accessible Dimmer Auto. Time Switch NA: Not daylit zone NA: Not daylit zone No 106-Operatory 1 General Commercial Industrial Work Area Precision Readily Accessible Dimmer Auto. Time Switch NA: Not daylit zone NA: Not daylit zone No 107-Hallway Corridor Readily Accessible NA: Enclosed area <100SF Auto. Time Switch NA: Not daylit zone NA: Not daylit zone No 108-CBCT General Commercial Industrial Work Area Precision Readily Accessible NA: Enclosed area <100SF Auto. Time Switch NA: Not daylit zone NA: Not daylit zone No 109-Sterile General Commercial Industrial Work Area Precision Readily Accessible Dimmer Auto. Time Switch NA: Not daylit zone NA: Not daylit zone No 110-Operatory 2 General Commercial Industrial Work Area Precision Readily Accessible Dimmer Auto. Time Switch NA: Not daylit zone NA: Not daylit zone No 111-Operatory 3 General Commercial Industrial Work Area Precision Readily Accessible Dimmer Auto. Time Switch NA: Not daylit zone NA: Not daylit zone No STATE OF CALIFORNIA Indoor Lighting CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-E Project Name: Dentist Office TI Report Page: (Page 5 of 9) Date Prepared: 2023-09-27T12:10:35-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0004 Report Generated: 2023-09-27 09:10:38 H. INDOOR LIGHTING CONTROLS (Not including PAFs) 112-Operatory 4 General Commercial Industrial Work Area Precision Readily Accessible Dimmer Auto. Time Switch NA: Not daylit zone NA: Not daylit zone No 13 Plan Sheet Showing Daylit Zones:   I. LIGHTING POWER ALLOWANCE: COMPLETE BUILDING OR AREA CATEGORY METHODS Each area complying using the Complete Building or Area Category Methods per 140.6(b) are included in this table. Column 06 indicates if additional lighting power allowances per 140.6(c) or adjustments per 140.6(a) are being used . Conditioned Spaces 01 02 03 04 05 06 Area Description Complete Building or Area Category Primary Function Area Allowed Density (W/ft2)Area (ft2)Allowed Wattage (Watts) Additional Allowance / Adjustment Area Category PAF 101-Lobby Main Entry Lobby 0.7 118 82.6 No No 102-Equipment Electrical Mechancial Telephone Room 0.4 33 13.2 No No 103-Office Office ( <=250 square feet)0.65 52 33.79 No No 104-Unisex Restroom Restroom 0.65 68 44.2 No No 105-Reception Lounge 0.55 196 107.8 No No 106-Operatory 1 General Commercial Industrial Work Area Precision 0.85 95 80.75 No No 107-Hallway Corridor 0.4 69 27.6 No No 108-CBCT General Commercial Industrial Work Area Precision 0.85 30 25.5 No No 109-Sterile General Commercial Industrial Work Area Precision 0.85 157 133.44 No No 110-Operatory 2 General Commercial Industrial Work Area Precision 0.85 115 97.75 No No 111-Operatory 3 General Commercial Industrial Work Area Precision 0.85 86 73.09 No No STATE OF CALIFORNIA Indoor Lighting CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-E Project Name: Dentist Office TI Report Page: (Page 6 of 9) Date Prepared: 2023-09-27T12:10:35-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0004 Report Generated: 2023-09-27 09:10:38 I. LIGHTING POWER ALLOWANCE: COMPLETE BUILDING OR AREA CATEGORY METHODS 112-Operatory 4 General Commercial Industrial Work Area Precision 0.85 85 72.25 No No TOTALS:1,104 792 See Tables J, or P for detail J. ADDITIONAL ALLOWANCE: AREA CATEGORY METHOD QUALIFYING LIGHTING SYSTEM This section does not apply to this project. K. TAILORED METHOD GENERAL LIGHTING POWER ALLOWANCE This section does not apply to this project. L. ADDITIONAL LIGHTING ALLOWANCE: TAILORED WALL DISPLAY This section does not apply to this project. M. ADDITIONAL LIGHTING ALLOWANCE: TAILORED FLOOR AND TASK LIGHTING This section does not apply to this project. N. ADDITIONAL LIGHTING ALLOWANCE: TAILORED DECORATIVE /SPECIAL EFFECTS This section does not apply to this project. O. ADDITIONAL LIGHTING ALLOWANCE: TAILORED VERY VALUABLE MERCHANDISE This section does not apply to this project. P. POWER ADJUSTMENT: LIGHTING CONTROL CREDIT (POWER ADJUSTMENT FACTOR (PAF)) This section does not apply to this project. STATE OF CALIFORNIA Indoor Lighting CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-E Project Name: Dentist Office TI Report Page: (Page 7 of 9) Date Prepared: 2023-09-27T12:10:35-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0004 Report Generated: 2023-09-27 09:10:38 Q. RATED POWER REDUCTION COMPLIANCE FOR ONE-FOR-ONE ALTERATIONS This section does not apply to this project. R. 80% LIGHTING POWER FOR ALL ALTERATIONS - CONTROLS EXCEPTIONS This section does not apply to this project. S. DAYLIGHT DESIGN POWER ADJUSTMENT FACTOR (PAF) This section does not apply to this project. T. DWELLING UNIT LIGHTING This section does not apply to this project. U. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION Selections have been made based on information provided in this document. If any selections have been changed by permit applicant, an explanation should be included in Table E. Additional Remarks. These documents must be provided to the building inspector during construction and can be found online Form/Title NRCI-LTI-E - Must be submitted for all buildings STATE OF CALIFORNIA Indoor Lighting CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-E Project Name: Dentist Office TI Report Page: (Page 8 of 9) Date Prepared: 2023-09-27T12:10:35-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0004 Report Generated: 2023-09-27 09:10:38 V. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE Selections have been made based on information provided in this document. If any selections have been changed by the permit applicant, an explanation should be included in Table E. Additional Remarks. These documents must be provided to the building inspector during construction and any with "-A" in the form name must be completed through an Acceptance Test Technician Certification Provider (ATTCP). For more information visit: http://www.energy.ca.gov/title24/attcp/providers.html Form/Title Systems/Spaces To Be Field Verified NRCA-LTI-02-A - Must be submitted for occupancy sensors and automatic time switch controls.101-Lobby; 102-Equipment; 103-Office; 104-Unisex Restroom; 105-Reception; 106-Operatory 1; 107-Hallway; 108-CBCT; 109-Sterile; 110-Operatory 2; 111-Operatory 3; 112-Operatory 4 STATE OF CALIFORNIA Indoor Lighting CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-E Project Name: Dentist Office TI Report Page: (Page 9 of 9) Project Address: Date Prepared: 2023-09-27T12:10:35-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0004 Report Generated: 2023-09-27 09:10:38 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (if applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Compliance is true and correct. 2.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer) 3.The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5.I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone: David Hensel, PE Hensel Consulting Engineers, Inc. 16776 Bernardo Center Dr., Suite 203 San Diego CA 92128 (619) 665-3259 M32901 9/28/2023 42 E. Huntington Dr. Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0005 Report Generated: 2023-09-27 09:37:54 STATE OF CALIFORNIA Mechanical Systems CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E This document is used to demonstrate compliance for mechanical systems that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in 140.4, or 141.0(b)2 for alterations. Project Name: Dentist Office TI Report Page: (Page 1 of 12) Project Address: Date Prepared: 2023-09-27T12:37:47-04:00 A. GENERAL INFORMATION 01 Project Location (city)Arcadia 04 Total Conditioned Floor Area 1019 02 Climate Zone 9 05 Total Unconditioned Floor Area 0 03 Occupancy Types Within Project:06 # of Stories (Habitable Above Grade)1 ● Medical Clinic B. PROJECT SCOPE This table Includes mechanical systems or components that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in 140.4, 170.2(b) or 141.0(b)2 and 180.2(b)2 for alterations. 01 02 03 Air System(s)Wet System Components Dry System Components Heating Air System Water Economizer Air Economizer Cooling Air System Pumps Electric Resistance Heat Mechanical Controls System Piping Fan Systems Mechanical Controls (existing to remain, altered or new)Cooling Towers Ductwork (existing to remain, altered or new) Chillers Ventilation Boilers Zonal Systems/ Terminal Boxes 42 E.Huntington Dr. STATE OF CALIFORNIA Mechanical Systems CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Dentist Office TI Report Page: (Page 2 of 12) Date Prepared: 2023-09-27T12:37:47-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0005 Report Generated: 2023-09-27 09:37:54 C. COMPLIANCE RESULTS Table C will indicate if the project data input into the compliance document is compliant with mechanical requirements. This table is not editable by the user. If this table says "DOES NOT COMPLY" or "COMPLIES with Exceptional Conditions" refer to Table D., or the table indicated as not compliant for guidance. 01 AND 02 AND 03 AND 04 AND 05 AND 06 AND 07 AND 08 09 System Summary 110.1, 110.2, 140.4, 170.2(c) Pumps 140.4(k), 170.2(c)4I Fans/ Economizers 140.4(c), 140.4(e), 170.2(c) System Controls 110.2, 120.2, 140.4(f), 170.2(c) Ventilation 120.1, 160.2 Terminal Box Controls 140.4(d), 170.2(c)4B Distribution 120.3, 140.4(l), 160.2, 160.3 Cooling Towers 110.2(e)2 Compliance Results (See Table F)(See Table G)(See Table H)(See Table I)(See Table J)(See Table K)(See Table L)(See Table M) Yes AND AND Yes AND Yes AND Yes AND AND Yes AND COMPLIES with Exceptional Conditions Mandatory Measures Compliance (See Table Q for Details)COMPLIES D. EXCEPTIONAL CONDITIONS This table is auto-filled with uneditable comments because of selections made or data entered in tables throughout the form. The permit applicant has indicated on Table J that ventilation calculations have been attached or included elsewhere on the plans. E. ADDITIONAL REMARKS This table includes remarks made by the permit applicant to the Authority Having Jurisdiction. F. HVAC SYSTEM SUMMARY (DRY & WET SYSTEMS) Space Conditioning System Information 01 02 03 04 05 06 System Name Quantity System Serving System Status Space Type Utilizing Recovered Heat HP-1 1 Multi-zone    STATE OF CALIFORNIA Mechanical Systems CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Dentist Office TI Report Page: (Page 3 of 12) Date Prepared: 2023-09-27T12:37:47-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0005 Report Generated: 2023-09-27 09:37:54 F. HVAC SYSTEM SUMMARY (DRY & WET SYSTEMS) Dry System Equipment Sizing (includes air conditioners, condensers, heat pumps, VRF, furnaces and unit heaters and DOAS systems) 01 02 03 04 05 06 07 08 09 10 11 Name or Item Tag Equipment Category per Tables 110.2, 140.4(a)2 and 170.2(c)3aii Equipment Type per Tables 110.2 and Title 20 Smallest Size Available1 140.4(a) and 170.2(c)1 Equipment Sizing per Mechanical Schedule (kBtu/h) 140.4(a&b), 170.2(c)1 & 170.2(c)2 Heating Output2,3 Cooling Output2,3 Load Calculations3,4 Per Design (kBtu/h) Rated (kBtu/h) Supp. Heating Output (kBtu/h) Sensible Per Design (kBtu/h) Rated (kBtu/h) Total Heating Load (kBtu/h) Total Sensible Cooling Load (kBtu/h) HP-1 Unitary Heat Pumps (no elec. resistance)Air-cooled, split (1phase)Yes 34.4 34.4 0 34.4 34.4 34.4 34.4 1FOOTNOTES: Equipment shall be the smallest size, within the available options of the desired equipment line, necessary to meet the design heating and cooling loads of the building per 140.4(a) and 170.2(c)1. Healthcare facilities are excepted. 2It is common practice to show rated output capacity on the equipment schedule. Sensible cooling output comes from specification sheet tables. 3 If equipment is heating only, leave cooling output and load blank. If equipment is cooling only, leave heating output and load blank. 4 Authority Having Jurisdiction may ask for load calculations used for compliance per 140.4(b) and 170.2(c). Dry System Equipment Efficiency (other than Package Terminal Air Conditioners (PTAC) and Package Terminal Heat Pumps (PTHP), DX-DOAS and Dual Fuel Heat Pumps) 01 02 03 04 05 06 07 08 09 Name or Item Tag Size Category (Btu/h) Heating Mode Cooling Mode Rating Condition ( °F) Efficiency Unit Minimum Efficiency Required per Tables 110.2 / Title 20 Design Efficiency Efficiency Unit Minimum Efficiency Required per Tables 110.2 / Title 20 Design Efficiency HP-1 <65,000  HSPF2 7.5 7.5 SEER2 14.3 14.3 G. PUMPS This section does not apply to this project. STATE OF CALIFORNIA Mechanical Systems CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Dentist Office TI Report Page: (Page 4 of 12) Date Prepared: 2023-09-27T12:37:47-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0005 Report Generated: 2023-09-27 09:37:54 H. FAN SYSTEMS & AIR ECONOMIZERS This table is used to demonstrate compliance with prescriptive requirements found in 140.4(c), 140.4(e), 140.4(m), 170.2(c)3, and 170.2(c)4A for fan systems. Fan systems serving only process loads are exempt from these requirements and do not need to be included in Table H. System Name CO-1 Supply Fan Quantit y 2 Fan System Status New System Zoning all other systems Serving Dwelling Units Not Serving Dwelling Units Fan System Airflow (cfm) 388 Site Elevation 0 Economizer NA: Special OA filtration 01 02 03 04 05 06 07 08 09 10 11 Fan Name or Item Tag Fan Type Qty Component Airflow through Component (%) Water Gauge (w.g) Allowance Design Compone nt Allowance Fan Allowance (watt/cfm) 3 Design Electrical Input Power Method Motor Nameplate Horsepower Design Electrical Input Power (kW) CO-1 Supply Fan Supply 2 Hydronic/DX cooling coil or heat pump coil 100  0.13 0.139 Manufacturer provided  0.1 Supply Fan Base Allowance (kW)0.232 Exhuast/Return/Relief/Transfer Fan Base Allowance(kW)0 Fan System Allowance (kW)3  Fan System Electrical Output (kW)0.2 STATE OF CALIFORNIA Mechanical Systems CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Dentist Office TI Report Page: (Page 5 of 12) Date Prepared: 2023-09-27T12:37:47-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0005 Report Generated: 2023-09-27 09:37:54 H. FAN SYSTEMS & AIR ECONOMIZERS System Name CO-2 Supply Fan Quantit y 1 Fan System Status New System Zoning all other systems Serving Dwelling Units Not Serving Dwelling Units Fan System Airflow (cfm) 317 Site Elevation 1 Economizer NA: Special OA filtration 01 02 03 04 05 06 07 08 09 10 11 Fan Name or Item Tag Fan Type Qty Component Airflow through Component (%) Water Gauge (w.g) Allowance Design Compone nt Allowance Fan Allowance (watt/cfm) 3 Design Electrical Input Power Method Motor Nameplate Horsepower Design Electrical Input Power (kW) CO-2 Supply Fan Supply 1 Hydronic/DX cooling coil or heat pump coil 100  0.13 0.139 Manufacturer provided  0.1 Supply Fan Base Allowance (kW)0.232 Exhuast/Return/Relief/Transfer Fan Base Allowance(kW)0 Fan System Allowance (kW)3  Fan System Electrical Output (kW)0.1 1 FOOTNOTES: Fans serving spaces with design background noise goals below NC35 2 Low-turndown single-zone VAV fan system must be capable of and configured to reduce airflow to 50 percent of design airflow and use no more than 30 percent of the design wattage at that airflow. No more than 10 percent of the design load served by the equipment shall have fixed loads. 3 Fan system allowance includes fan system base allowance. 4 Filter pressure loss can only be counted once per fan system. 5 Complex Fan System means a fan system that combines a single cabinet fan system with other supply fans, exhaust fans, or both. 6 Computer room economizers must meet requirements of 140.9(a) and will be documented on the NRCC-PRC-E document.. H. EXHAUST AIR HEAT RECOVERY 140.4(q), 170.2(c)4O 01 02 03 04 05 06 07 08 09 10 11 STATE OF CALIFORNIA Mechanical Systems CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Dentist Office TI Report Page: (Page 6 of 12) Date Prepared: 2023-09-27T12:37:47-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0005 Report Generated: 2023-09-27 09:37:54 H. EXHAUST AIR HEAT RECOVERY 140.4(q), 170.2(c)4O Fan System Name Qty Hours of Operation per Year Design Supply Airflow Rate Outdoor Airflow % Outdoor Air at Full Design Airflow Exemptions to Exhaust Air Heat Recovery Requirement per 140.4(q) & 170.2(c)4O Exhaust Air Heat Recovery 140.4(q) & 170.2(c)4O Type Of Heat Recovery Rating Required Recovery Ratio Energy Recovery Bypass CO-1 Supply Fan 2 < 8,000 388 60 0.15 No Exemptions Apply Not Required     CO-2 Supply Fan 1 < 8,000 317 45 0.14 No Exemptions Apply Not Required     Fan Energy Index (FEI) 01 02 03 Name or Item Tag FEI Exception FEI CO-1 Supply Fan Embedded Fan Regulated under 110.2 or 110.1   CO-2 Supply Fan Embedded Fan Regulated under 110.2 or 110.1   I. SYSTEM CONTROLS This table is used to demonstrate compliance with mandatory controls in 110.2 and 120.2 and prescriptive controls in 140.4(f) and (n), 170.2(c)4D 170.2(c)4L or requirements in 141.0(b)2E 180.2(b)2 for altered space conditioning systems. 01 02 03 04 05 06 07 08 09 System Name System Zoning Conditioned Floor Area Being Served (ft2) Thermostats 110.2(b) & (c)1, 120.2(a) 160.3(a)2A or 141.0(b)2E & 180.2(b)2 Shut-Off Controls 120.2(e) & 160.3(a)2D Isolation Zone Controls 120.2(g) & 160.3(a)2F Demand Response 110.12 120.2(b) & 160.3(a)2B Supply Air Temp. Reset 140.4(f) & 170.2(c)4D Window Interlocks per 140.4(n) & 170.2(c)4D Heat Pump Controls Multi-zone <= 25,000 ft2 Setback + DR Tstat per 110.12 Auto Timer Switch Auto Timer Switch DR Tstat per 110.12 NA: Controls prevent reheat/recoo l/simultaneo us NA: Alteration Project STATE OF CALIFORNIA Mechanical Systems CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Dentist Office TI Report Page: (Page 7 of 12) Date Prepared: 2023-09-27T12:37:47-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0005 Report Generated: 2023-09-27 09:37:54 I. SYSTEM CONTROLS 1FOOTNOTES: Gravity gas wall heaters, gravity floor heaters, gravity room heaters, non-central electric heaters, fireplaces or decorative gas appliances, wood stoves are not required to have setback thermostats. J. VENTILATION AND INDOOR AIR QUALITY This table is used to demonstrate compliance with mandatory ventilation requirements in 120.1 120.2(e)3B 140.4(p) and 140.4(q) for all nonresidential and hotel/motel and d:t24refnolink/]160.2, 160.3(a)3D, 170.2(a)4N, 170.2(a)4O for high-rise residential occupancies. For alterations, only ventilation systems being altered within the scope of the permit application need to be documented in this table. In lieu of this table, the required outdoor ventilation rates and airflows may be shown on the plans or the calculations can be presented in a spreadsheet. 01 Check the box if the project is showing ventilation calculations on the plans, or attaching the calculations instead of completing this table. 02 Check this box if the project included Nonresidential, Hotel/Motel Spaces or Multifamily Common Use Spaces 03 Check the box if the project is using natural ventilation in any nonresidential or hotel/motel spaces to meet required ventilation rates per 120.1(c)2. K. TERMINAL BOX CONTROLS This section does not apply to this project. L. DISTRIBUTION (DUCTWORK and PIPING) This table is used to show compliance with mandatory pipe insulation requirements found in 120.3 and mandatory requirements found in 120.4(g) for duct sealing. 01 Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall be installed with a cover suitable for outdoor service. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I or Class II vapor retarder. All penetrations and joints of which shall be sealed. Duct Leakage Testing The answers to the questions below apply to the following duct systems:CO-1 Duct System NR/ Common Use:Duct leakage testing shall not exceed 6% per NA7.5.3 required for these systems?No STATE OF CALIFORNIA Mechanical Systems CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Dentist Office TI Report Page: (Page 8 of 12) Date Prepared: 2023-09-27T12:37:47-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0005 Report Generated: 2023-09-27 09:37:54 L. DISTRIBUTION (DUCTWORK and PIPING) Dwelling Units:Total duct leakage of duct system shall not exceed 12% or duct system to outside shall not exceed 6% per RA3.1.4 required for systems? --- Duct leakage testing per CMC Section 603.10.1 required for these systems?Yes 11 No The scope of the project includes only duct systems serving healthcare facilities 12 No Duct system provides conditioned air to an occupiable space for a constant volume, single zone, space-conditioning system. 13 Yes The space conditioning system serves less than 5,000 ft2 of conditioned floor area. 14 Yes The combined surface area of the ducts is more than 25% of the total surface area of the entire duct system: 15 No The scope of the project includes extending an existing duct system, which is constructed, insulated or sealed with asbestos. 16 No The scope of the project includes an existing duct system that is documented to have been previously sealed as confirmed through field verification and diagnostic testing in accordance with procedures in the Reference Nonresidential Appendix NA2. 17 Yes All Ductwork and plenums with pressure class ratings shall be constructed to Seal Class A 18 No All ductwork is an extension of an existing duct system 19 No Ductwork serving individual dwelling unit 20 < 25 ft of new or replacement space conditioning ducts installed 21 R-8 Duct Insulation R-value 22 No Ductwork Existing To Remain 23 No Duct System Connected To Altered Space Conditioning System The answers to the questions below apply to the following duct systems:CO-1 Duct System NR/ Common Use:Duct leakage testing shall not exceed 6% per NA7.5.3 required for these systems?No STATE OF CALIFORNIA Mechanical Systems CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Dentist Office TI Report Page: (Page 9 of 12) Date Prepared: 2023-09-27T12:37:47-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0005 Report Generated: 2023-09-27 09:37:54 L. DISTRIBUTION (DUCTWORK and PIPING) Dwelling Units:Total duct leakage of duct system shall not exceed 12% or duct system to outside shall not exceed 6% per RA3.1.4 required for systems? --- Duct leakage testing per CMC Section 603.10.1 required for these systems?Yes 11 No The scope of the project includes only duct systems serving healthcare facilities 12 No Duct system provides conditioned air to an occupiable space for a constant volume, single zone, space-conditioning system. 13 No The space conditioning system serves less than 5,000 ft2 of conditioned floor area. 14 Yes The combined surface area of the ducts is more than 25% of the total surface area of the entire duct system: 15 No The scope of the project includes extending an existing duct system, which is constructed, insulated or sealed with asbestos. 16 No The scope of the project includes an existing duct system that is documented to have been previously sealed as confirmed through field verification and diagnostic testing in accordance with procedures in the Reference Nonresidential Appendix NA2. 17 Yes All Ductwork and plenums with pressure class ratings shall be constructed to Seal Class A 18 No All ductwork is an extension of an existing duct system 19 No Ductwork serving individual dwelling unit 20 < 25 ft of new or replacement space conditioning ducts installed 21 R-8 Duct Insulation R-value 22 No Ductwork Existing To Remain 23 No Duct System Connected To Altered Space Conditioning System The answers to the questions below apply to the following duct systems:CO-2 Duct System NR/ Common Use:Duct leakage testing shall not exceed 6% per NA7.5.3 required for these systems?No STATE OF CALIFORNIA Mechanical Systems CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Dentist Office TI Report Page: (Page 10 of 12) Date Prepared: 2023-09-27T12:37:47-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0005 Report Generated: 2023-09-27 09:37:54 L. DISTRIBUTION (DUCTWORK and PIPING) Dwelling Units:Total duct leakage of duct system shall not exceed 12% or duct system to outside shall not exceed 6% per RA3.1.4 required for systems? --- Duct leakage testing per CMC Section 603.10.1 required for these systems?Yes 11 No The scope of the project includes only duct systems serving healthcare facilities 12 No Duct system provides conditioned air to an occupiable space for a constant volume, single zone, space-conditioning system. 13 No The space conditioning system serves less than 5,000 ft2 of conditioned floor area. 14 Yes The combined surface area of the ducts is more than 25% of the total surface area of the entire duct system: 15 No The scope of the project includes extending an existing duct system, which is constructed, insulated or sealed with asbestos. 16 No The scope of the project includes an existing duct system that is documented to have been previously sealed as confirmed through field verification and diagnostic testing in accordance with procedures in the Reference Nonresidential Appendix NA2. 17 Yes All Ductwork and plenums with pressure class ratings shall be constructed to Seal Class A 18 No All ductwork is an extension of an existing duct system 19 No Ductwork serving individual dwelling unit 20 < 25 ft of new or replacement space conditioning ducts installed 21 R-8 Duct Insulation R-value 22 No Ductwork Existing To Remain 23 No Duct System Connected To Altered Space Conditioning System M. COOLING TOWERS This section does not apply to this project. STATE OF CALIFORNIA Mechanical Systems CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Dentist Office TI Report Page: (Page 11 of 12) Date Prepared: 2023-09-27T12:37:47-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0005 Report Generated: 2023-09-27 09:37:54 N. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION Selections have been made based on information provided in previous tables of this document. If any selection needs to be changed, please explain why in Table E Additional Remarks. These documents must be provided to the building inspector during construction and can be found online at https://www.energy.ca.gov/title24/2019standards/2019_compliance_documents/Nonresidential_Documents/NRCI/ Form/Title NRCI-MCH-01-E - Must be submitted for all buildings O. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE Selections have been made based on information provided in previous tables of this document. If any selection needs to be changed, please explain why in Table E Additional Remarks. These documents must be provided to the building inspector during construction and can be found online at https://www.energy.ca.gov/title24/2019standards/2019_compliance_documents/Nonresidential_Documents/NRCA/ Form/Title Systems/Spaces To Be Field Verified NRCA-MCH-02-A - Outdoor Air must be submitted for all newly installed HVAC units. Note: MCH-02-A can be performed in conjunction with MCH-07-A Supply Fan VFD Acceptance (if applicable) since testing activities overlap. P. DECLARATION OF REQUIRED CERTIFICATES OF VERIFICATION There are no NRCV forms required for this project. Q. MANDATORY MEASURES DOCUMENTATION LOCATION This table is used to indicate where mandatory measures are documented in the plan set or construction documentation. 01 02 Compliance with Mandatory Measures documented through MCH Mandatory Measures Note Block Yes Plan sheet or construction document location M-1 STATE OF CALIFORNIA Mechanical Systems CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Dentist Office TI Report Page: (Page 12 of 12) Project Address: Date Prepared: 2023-09-27T12:37:47-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0005 Report Generated: 2023-09-27 09:37:54 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (if applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Compliance is true and correct. 2.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer) 3.The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5.I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone: 42 E.Huntington Dr. David Hensel, PE Hensel Consulting Engineers, Inc. 16776 Bernardo Center Dr., Suite 203 San Diego CA 92128 9/28/2023 M32901 (619) 665-3259 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0003 Report Generated: 2023-09-27 08:44:38 STATE OF CALIFORNIA Domestic Water Heating System CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-PLB-E This document is used to demonstrate compliance for nonresidential occupancies with requirements in 110.1, 110.3, 120.3, and 140.5, and with requirements in 141.0 for additions and alterations, for domestic water heating scopes using the prescriptive path. For high-rise residential and hotel/motel occupancies compliance is demonstrated with requirements in 110.1, 110.3, 160.4 and 170.2(d), and with requirements 180.1 for additions and 180.2 for alterations. Project Name: Dentist Office TI Report Page: (Page 1 of 8) Project Address: Date Prepared: 2023-09-27T11:44:36-04:00 A. GENERAL INFORMATION 01 Project Location (city)Arcadia 02 Climate Zone 9 03 Occupancy Types Within Project (select all that apply): ● Medical Clinic B. PROJECT SCOPE This table includes domestic water heating systems that are within the scope of the permit application and are demonstrating compliance using the prescriptive paths outlined in 140./ 170.2(d) and 141.0(a)/ 180.1, or 141.0(b)2N / 180.2 for additions or alterations. Solar water heating systems are documented on the NRCC-SAB compliance document. Combined hydronic water heating systems are documented on the NRCC-MCH compliance document. 01 02 03 My project consists of (check all that apply):System Type1,2 System Components New system (DHW system being installed for the first time)Central System (serving nonresidential spaces)Equipment Distribution Controls System Alteration (equipment, distribution or controls)Equipment Distribution Controls 1FOOTNOTES: Point of use water heaters, or other non-central systems used to serve nonresidential spaces, are considered individual systems. 2 Dwelling units refers to hotel/motel guest rooms and units in a multifamily residential occupancy. 3 DHW systems serving 2 or more dwelling units are considered "Central Systems" for multifamily occupancies C. COMPLIANCE RESULTS Table C will indicate if the project data input into the compliance document is compliant with water heating requirements. If this table says "DOES NOT COMPLY" or "COMPLIES with Exceptional Conditions" refer to Table D. or the table indicated as not compliant for guidance. 01 02 03 04 Domestic Hot Water Equipment Distribution Systems Controls Compliance ResultsTable F Table G Table H Yes Yes Yes COMPLIES D. EXCEPTIONAL CONDITIONS This table is auto-filled with uneditable comments because of selections made or data entered in tables throughout the form. 42 E.Huntington Dr. STATE OF CALIFORNIA Domestic Water Heating System CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-PLB-E Project Name: Dentist Office TI Report Page: (Page 2 of 8) Date Prepared: 2023-09-27T11:44:36-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0003 Report Generated: 2023-09-27 08:44:38 E. ADDITIONAL REMARKS This table includes remarks made by the permit applicant to the Authority Having Jurisdiction. STATE OF CALIFORNIA Domestic Water Heating System CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-PLB-E Project Name: Dentist Office TI Report Page: (Page 3 of 8) Date Prepared: 2023-09-27T11:44:36-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0003 Report Generated: 2023-09-27 08:44:38 F. DOMESTIC HOT WATER EQUIPMENT This table is used to demonstrate compliance with mandatory equipment requirements in 110.1 and 110.3. Compliance with prescriptive requirements in 140.5(c) / 170.2(d) must also be demonstrated and with 141.0 / 180.1/ 180.2 for addition and alteration scopes. Equipment Schedule: Water Heating Efficiency and Standby Loss 03 04 05 06 System Name WH Exception to 140.5(c)/ 170.2(d)3 Exceptions Do Not Apply Gas Service Water Heating System >= 1MMBtu/h1 Capacity-weighted Average Efficiency %  07 08 09 10 11 12 13 14 15 Name or Item Tag Equipment Type Volume (gal) Rated Input Capacity (Btu/h) Max GPM/ First Hour Rating (FHR) Rated Efficiency Minimum Efficiency Required Efficiency Unit Designed Standby Loss Maximum Standby Loss 20 Gallon Electric Water Heater Consumer Rated Electric Storage <=30 6,825 0 <= FHR <18 0.86 0.86 UEF    1FOOTNOTE: In systems >= 1MMBtu/h with multiple units, gas water heaters with input capacity > 100,000 Btu/h may meet 90% Et requirements via an input capacity-weighted average. 1FOOTNOTE: Compliant equipment may be found in the Modernized Appliance Efficiency Database System (MAEDBS) on the Energy Commission website: https://cacertappliances.energy.ca.gov/Pages/Search/AdvancedSearch.aspx Water Heating Equipment All Occupancies Yes No Not Applicable Requirement 18 Unfired storage tank insulation shall have Internal + External >=R-16 OR External >=R-3.5. Label required per 110.3(c)3 19 New state buildings 60% of energy for service water heating from site solar energy or recovered energy per 110.3(c)5 20 Isolation valves for instantaneous water heater with input rating >6.8 kBTUH or 2 kW has been specified per 110.3(c)6 21 School buildings < 25,000 ft2 and < 4 stories must install a heat pump water heating system per 140.5(a)1. Water heating systems serving an individual bathroom space may be an instantaneous electric water heater. STATE OF CALIFORNIA Domestic Water Heating System CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-PLB-E Project Name: Dentist Office TI Report Page: (Page 4 of 8) Date Prepared: 2023-09-27T11:44:36-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0003 Report Generated: 2023-09-27 08:44:38 G. DOMESTIC HOT WATER DISTRIBUTION SYSTEM This table is used to demonstrate compliance for nonresidential occupancies with distribution requirements in 120.3 and 140.5. For multifamily and hotel/motel occupancies, compliance is demonstrated with requirements 110.3(c), 160.4, 170.2(d). Recirculation Loops in Central Systems Serving Dwelling Units or Nonresidential Spaces Yes No Not Applicable Requirement 01 Air release valve or vertical pump installation per 110.3(c)4A 02 Check valve or similar located between recirculation pump and water heating equipment to prevent backflow per 110.3(c)4B 03 Hose bibb installed between pump and equipment and isolation valve between hose bibb and equipment per 110.3(c)4C 04 Isolation valves on both sides of the pump per 110.3(c)4D 05 Cold water and recirculation loop piping shall not be connected to the hot water storage tank drain port per 110.3(c)4E 06 Check valve installed on cold water supply between hot water system and next closest tee on cold water supply per 110.3(c)4F 07 DWELLING UNITS ONLY: For central systems serving multiple dwelling units, design includes a recirculation system serving separate dwelling units per 170.2(d) unless building has <=8 dwelling units. 08 DWELLING UNITS ONLY: For heat pump water heating systems, the hot water return from the recirculation loop shall connect to a recirculation loop tank and shall not directly connect to the primary heat pump water heater inlet or the primary thermal storage tanks per 170.2(d)2A. 09 DWELLING UNITS ONLY: For heat pump water heating systems, the fuel source for the recirculation loop tank shall be electricity if auxiliary heating is needed. The recirculation loop heater shall be capable of multi-pass water heating operation per 170.2(d)2B. STATE OF CALIFORNIA Domestic Water Heating System CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-PLB-E Project Name: Dentist Office TI Report Page: (Page 5 of 8) Date Prepared: 2023-09-27T11:44:36-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0003 Report Generated: 2023-09-27 08:44:38 G. DOMESTIC HOT WATER DISTRIBUTION SYSTEM Mandatory Pipe Insulation All Occupancies 13 For systems serving dwelling units, pipe insulation must meet the minimum insulation requirements in Table 160.4-A (see blow) except: •Piping that penetrates framing members shall not be required to have pipe insulation for the distance of the framing penetration. Piping that penetrates metal framing shall use grommets, plugs, wrapping or other insulating material to assure that no contact is made with the metal framing. Insulation shall abut securely against all framing members •Piping installed in interior or exterior walls shall not be required to have pipe insulation if all of the requirements are met for compliance with Quality Insulation Installation (QII) as specified in the Reference Residential Appendix RA3.5. •Piping surrounded with a minimum of 1 inch of wall insulation, 2 inches of crawlspace insulation, or 4 inches of attic insulation, shall not be required to have pipe insulation. 14 For systems serving nonresidential spaces, pipe insulation for the following applications is specified to comply with Table 120.3-A (see below) per 120.3: •Recirculating system piping, including supply and return piping of the water heater •The first 8 ft of hot and cold outlet piping, including between storage tank and heat trap, for a nonrecirculating storage system •Pipes that are externally heated 15 Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall be installed with a cover suitable for outdoor service per 120.3(b) / 160.4(f). Pipe insulation buried below grade must be installed in a water proof and non-crushable casing or sleeve. TABLE 120.3-A / 160.4-A PIPE INSULATION THICKNESS Fluid Temperature Range ( °F) Conductivity Range (Btu-in per hour per ft2 per °F) Insulation Mean Rating Temp ( °F) Nominal Pipe Diameter (in) < 1 1 to < 1.5 1.5 to < 4 1.5 to < 4 Multifamily & Hotel/Motel Minimum Insulation Required 105-140 0.22 - 0.28 100 1.0 in or R-7.7 1.5 in or R-12.5 1.5 in or R-11 2.0 in or R-16 STATE OF CALIFORNIA Domestic Water Heating System CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-PLB-E Project Name: Dentist Office TI Report Page: (Page 6 of 8) Date Prepared: 2023-09-27T11:44:36-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0003 Report Generated: 2023-09-27 08:44:38 H. DOMESTIC HOT WATER CONTROLS This table is used to demonstrate compliance with control requirements in 110.3 for all occupancies. For multifamily residential and hotel/motel occupancies, compliance is also demonstrated with requirements in 160.4(e) / 170.2(d). Yes No Not Applicable Requirement 01 Construction documents require manufacturer certification that service water-heating systems are equipped with automatic temperature controls capable of adjusting temperature settings per 110.3(a). 02 Systems with capacity > 167,000 BTUH equipped with outlet temperature controls per 110.3(c)1 unless covered by California Plumbing Code 613.0. 03 Controls for circulating pumps or electrical heat trace systems are capable of automatically turning off the system per §110.3(c)2  unless systems serves healthcare facility. 04 For recirculation systems serving multiple dwelling units, design includes automatic pump controls per 170.2(d) or 180.1(b)3 for additions. 05 For recirculation systems serving individual dwelling units, design includes manual on/off controls as specified in Reference Appendix RA4.4.9 per 170.2(d). 06 Combustion air positive shut-off shall be provided per 160.4(3).on all newly installed commercial boilers as follows: •Boilers with input capacity >= 2.5 MMBtu/h, in which the boiler is designed to operate with a nonpositive vent static pressure •Boilers where one stack serves two or more boilers with a total combined input capacity per stack of 2.5 MMBtu/h. 07 Boiler combustion air fans with motor >= 10 hp shall meet one of the following •The fan motor shall be driven by a variable speed drive OR •The fan motor shall include controls that limit the fan motor demand to <=30% of the total design wattage at 50% of the design air volume. 08 Newly installed boilers with an input capacity {d:gte/] 5MMBtu/h and a steady state full-load combustion efficiency < 90% shall maintain excess (stack-gas) oxygen concentrations <= 5% by volume on a dry basis over firing rates of 20-100%. Combustion air volume shall be controlled with respect to firing rate or flue gas oxygen concentration. Use of a common gas and combustion air control linkage or jack shaft is prohibited. STATE OF CALIFORNIA Domestic Water Heating System CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-PLB-E Project Name: Dentist Office TI Report Page: (Page 7 of 8) Date Prepared: 2023-09-27T11:44:36-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0003 Report Generated: 2023-09-27 08:44:38 I. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION Selections have been made based on information provided in this document. If any selection have been changed by permit applicant, an explanation should be included in Table E. Additional Remarks. These documents must be provided to the building inspector during construction and can be found online Form/Title NRCI-PLB-E - Must be submitted for all buildings J. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE There are no forms required for this project. K. DECLARATION OF REQUIRED CERTIFICATES OF VERIFICATION There are no forms required for this project. STATE OF CALIFORNIA Domestic Water Heating System CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-PLB-E Project Name: Dentist Office TI Report Page: (Page 8 of 8) Project Address: Date Prepared: 2023-09-27T11:44:36-04:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 145100-0923-0003 Report Generated: 2023-09-27 08:44:38 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (if applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Compliance is true and correct. 2.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer) 3.The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5.I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone: David Hensel, PE Hensel Consulting Engineers, Inc. 16776 Bernardo Center Dr., Suite 203 San Diego CA 92128 (619) 665-3259 M32901 9/28/2023 42 E.Huntington Dr.