DESIGN CRITERIA
BUILDING CODE:
2019 CALIFORNIA BUILDING CODE
WIND DESIGN DATA:
WIND SPEED (ULTIMATE) = 110 MPH
WIND RISK CATEGORY = II
WIND EXPOSURE = C
INTERNAL PRESSURE COEFFICIENT = ± 0.18
SEISMIC DESIGN DATA:
SS = 1.936; S1 = 0.382; SMS = 2.323; SDS = 1.549
SEISMIC IMPORTANCE FACTOR = 1.0
RISK CATEGORY = II
SEISMIC DESIGN CATEGORY = D
SITE CLASS = D
REDUNDANCY FACTOR = 1.0
ANALYSIS PROCEDURE:EQUIVALENT LATERAL FORCE PROCEDURE
SEISMIC FORCE RESISTING SYSTEM:
LIGHT-FRAME (WOOD) WALLS SHEATHED W/ WOOD STRUCTURAL PANELS RATED FOR SHEAR RESISTANCE
CS = 0.239; R = 6.5
LOADING:
DEAD LOAD:LIVE LOAD:
ROOF = 21 PSF; FLOOR = 19 PSF; DECK = 13 PSF ROOF = 20 PSF;FLOOR = 40 PSF; DECK = 60 PSF
GEOTECHNICAL INFORMATION:
GEOTECHNICAL ENGINEER:CAL LAND ENGINEERING, INC.
SOIL REPORT #:19-019-007GE
SOIL REPORT DATE:SEPTEMBER 29, 2021
BEARING CAPACITY =2,000 PSF
ABBREVIATIONS
ABBREVIATION DESCRIPTION
AB ANCHOR BOLT
ADD'L ADDITIONAL
ADJ ADJACENT
ABV ABOVE
ALT ALTERNATE
ARCH ARCHITECTURAL
B BOTTOM
BLDG BUILDING
BLKG BLOCKING
BLW BELOW
BM BEAM
BN BOUNDARY NAILING
BOT BOTTOM
BRG BEARING
C CAMBER
CANT CANTILEVER
CB CEILING BEAM
CBC CALIFORNIA
BUILDING CODE
CJ CEILING JOIST
CL CENTERLINE
CLG CEILING
CLR CLEAR
CMU CONCRETE
MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECT, CONNECTION
CONT CONTINUOUS
D DEEP, DEPTH
DF DOUGLAS FIR LARCH
DIA DIAMETER
DIM DIMENSION
DJ DECK JOIST
DL DEAD LOAD
DT DRAG TRUSS
DWG DRAWING(S)
E OR EXIST EXISTING
EA EACH
ELEV ELEVATION
ENGR ENGINEER
EQ EQUAL
ES EACH SIDE
EW EACH WAY
EXT EXTERIOR
FND FOUNDATION
FF FINISH FLOOR
FG FINISH GRADE
FH FULL HEIGHT
FJ FLOOR JOIST
ABBREVIATION DESCRIPTION
FL FLUSH
FLR FLOOR
F.O.B.FACE OF BEAM
F.O.W.FACE OF WALL
FRG FRAMING
FTG FOOTING
FT FOOT (FEET)
GA GAGE
GALV GALVINIZED
G.C.GENERAL CONTRACTOR
GET GABLE END TRUSS
GLB GLU LAM BEAM
GT GIRDER TRUSS
H OR HT HEIGHT
HB HIP BEAM
HD HOLD DOWN STRAP
OR DEVICE
HDR HEADER
HGR OR HNGR HANGER
HOR HORIZONTAL
HSS HOLLOW STRUCTURAL
STEEL (TUBE)
INT INTERIOR
INV INVERTED
JST JOIST
K KIP (1000 POUNDS)
KP KING POST
KS KING STUD
LL LIVE LOAD
LSL LAMINATED STRAND
LUMBER
LVL LAMINATED VENEER
LUMBER
MANUF MANUFACTURER,
MANUFACTURED
MAX MAXIMUM
MB MACHINE BOLT
MIN MINIMUM
ML MICROLLAM
MULT MULTIPLE
N NEW
NG NATURAL OR
COMPACTED GRADE
NTS NOT TO SCALE
O/OVER
O.C.ON CENTER
OD OUTSIDE DIAMETER
PERP PERPENDICULAR
PSL PARALLAM
PT POST TENSION
SHEET INDEX
SD0 STRUCTURAL SPECIFICATIONS
SP SPECIAL INSPECTIONS
S1 FOUNDATION PLAN
S2 2ND FLOOR FRAMING PLAN
S3 3RD FLOOR FRAMING PLAN
S4 ROOF FRAMING PLAN
SD1 STRUCTURAL DETAILS
SD2 STRUCTURAL DETAILS
SD3 STRUCTURAL DETAILS
SD4 STRUCTURAL DETAILS
SD5 STRUCTURAL DETAILS
ABBREVIATION DESCRIPTION
PTDF PRESSURE TREATED
DOUGLAS FIR
PLYWD PLYWOOD
PSI POUNDS PER
SQUARE INCH
PSF POUNDS PER
SQUARE FOOT
RAFT RAFTER
RB RIDGE BEAM
RR ROOF RAFTER
REINF REINFORCEMENT
RF ROOF
REQ'D REQUIRED
REQ'T REQUIREMENT
RT ROOF TRUSS(ES)
SAD SEE ARCHITECTURAL
DRAWINGS
SCHED OR SCH SCHEDULE
SEL SELECT
SHR SHEAR
SHTG SHEATHING
SIM SIMILAR
SIMP SIMPSON
SPECS SPECIFICATIONS
SQ SQUARE
STAGG STAGGERED
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
SW SHEAR WALL OR
STRONG WALL
SYM SYMMETRICAL
T TOP
TOC TOP OF CURB
TOS TOP OF SLAB
OR TOP OF STEEL
T&G TONGUE AND GROOVE
THK THICK
TRIM OR TR TRIMMER
TS TIMBERSTRAND
TYP TYPICAL
UNO UNLESS NOTED
OTHERWISE
V OR VERT VERTICAL
VB VALLEY BEAM
VIF VERIFY IN FIELD
WD WOOD
WT WEIGHT
W/WITH
W/O WITHOUT
Q:FASTENING SCHEDULE (PER SECTION 2308.10.1, TABLE 2308.10.1)
FOR SI:1 INCH = 25.4MM
A.COMMON OR BOX NAILS ARE PERMITTED TO BE USED EXCEPT WHERE OTHERWISE STATED.
B.NAILS SPACED AT 6 INCHES ON CENTER AT EDGES, 12 INCHES AT INTERMEDIATE SUPPORTS EXCEPT 6 INCHES AT
SUPPORTS WHERE SPANS ARE 48 INCHES OR MORE. FOR NAILING OF WOOD STRUCTURAL PANEL AND
PARTICLEBOARD DIAPHRAGMS AND SHEAR WALLS, REFER TO SECTION 2305. NAILS FOR WALL SHEATHING ARE
PERMITTED TO BE COMMON, BOX OR CASING.
C.COMMON OR DEFORMED SHANK. (6d-2" X 0.113"; 8d-212" X 0.131"; 10d-3" X 0.148").
D.COMMON (6d-2" X 0.113"; 8d-212" X 0.131"; 10d-3" X 0.148").
E.DEFORMED SHANK. (6d-2" X 0.113"; 8d-212" X 0.131"; 10d-3" X 0.148").
F.CORROSION-RESISTANT SIDING (6d-178" X 0.106"; 8d-238" X 0.128") OR CASING (6d-2" X 0.099"; 8d-212" X 0.113") NAIL.
G.FASTENERS SPACED 3 INCHES ON CENTER AT EXTERIOR EDGES AND 6 INCHES ON CENTER AT INTERMEDIATE
SUPPORTS, WHEN USED AS STRUCTURAL SHEATHING. SPACING SHALL BE 6 INCHES ON CENTER ON THE EDGES
AND 12 INCHES ON CENTER AT INTERMEDIATE SUPPORTS FOR NONSTRUCTURAL APPLICATIONS.
H.CORROSION-RESISTANT ROOFING NAILS WITH 716 INCH DIAMETER HEAD AND 112 INCH LENGTH FOR 12 INCH
SHEATHING AND 134 INCH LENGTH FOR 2532 INCH SHEATHING.
J.CASING (112" X 0.080") OR FINISH (112" X 0.072") NAILS SPACED 6 INCHES ON PANEL EDGES, 12 INCHES AT
INTERMEDIATE SUPPORTS.
K.PANEL SUPPORTS AT 24 INCHES. CASING OR FINISH NAILS SPACED 6 INCHES ON PANEL EDGES, 12 INCHES AT
INTERMEDIATE SUPPORTS.
L.FOR ROOF SHEATHING APPLICATIONS, 8d NAILS (212" X 0.113") ARE THE MINIMUM REQUIRED FOR WOOD
STRUCTURAL PANELS.
N.FOR ROOF SHEATHING APPLICATIONS, FASTENERS SPACED 4 INCHES ON CENTER AT EDGES, 8 INCHES AT
INTERMEDIATE SUPPORTS.
O.FASTENERS SPACED 4 INCHES ON CENTER AT EDGES, 8 INCHES AT INTERMEDIATE SUPPORTS FOR SUBFLOOR
AND WALL SHEATHING AND 3 INCHES ON CENTER AT EDGES, 6 INCHES AT INTERMEDIATE SUPPORTS FOR ROOF
SHEATHING
FASTENING
3-8d COMMON (212" X 0.131")
3-3" X 0.131" NAILS
LOCATION
TOENAIL
CONNECTION
1.JOIST TO SILL OR GIRDER
A
2-8d COMMON (212" X 0.131")
2-3" X 0.131" NAILS
2.BRIDGING TO JOIST TOENAIL EACH END
3.1" X 6" SUBFLOOR OR LESS TO EACH JOIST 2-8d COMMON (212" X 0.131")FACE NAIL
4.WIDER THAN 1" X 6" SUBFLOOR TO EACH JOIST 3-8d COMMON (212" X 0.131")FACE NAIL
5.2" SUBFLOOR TO JOIST OR GIRDER 2-16d COMMON (312" X 0.162")BLIND AND FACE NAIL
6.SOLE PLATE TO JOIST OR BLOCKING 16d (312" X 0.135") AT 16" O.C.
3" X 0.131" NAILS AT 8" O.C.
TYPICAL FACE NAIL
16d (312" X 0.135") AT 16"
4-3" X 0.131" NAILS AT 16"
SOLE PLATE TO JOIST OR BLOCKING AT BRACED
WALL PANEL
BRACED WALL PANELS
7.TOP PLATE TO STUD 2-16d COMMON (312 X 0.162")
3-3" X 0.131" NAILS
END NAILS
8.STUDS TO SOLE PLATE 4-8d COMMON (212" X 0.131")
4-3" X 0.131" NAILS
TOENAIL
2-16d COMMON (312" X 0.162")
3-3" X 0.131" NAILS
END NAILS
9.DOUBLE STUDS 16d (312 X 0.135") AT 24" O.C.
3" X 0.131" NAIL AT 8" O.C.
FACE NAILS
16d (312" X 0.131") AT 16" O.C.
3" X 0.131" NAIL AT 12" O.C.
8-16d COMMON (312" X 0.162")
12-3" X 0.131" NAILS
LAP SPLICE
TYPICAL FACE NAIL10.DOUBLE TOP PLATES
DOUBLE TOP PLATES
3-8d COMMON (212" X 0.131")
3-3" X 0.131" NAILS
11.BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP
PLATE
TOENAIL
12.RIM JOIST TO TOP PLATE 8d (212" X 0.131") AT 6" O.C.
3" X 0.131" NAIL AT 6" O.C.
TOENAIL
2-16d COMMON (312" X 0.162")
3-3" X 0.131" NAILS
FACE NAIL13.TOP PLATES, LAPS AND INTERSECTIONS
14.CONTINUOUS HEADER, TWO PIECES 16d COMMON (312" X 0.162")16" O.C. ALONG EDGE
15.CEILING JOISTS TO PLATE 3-8d COMMON (212" X 0.131")
5-3" X 0.131" NAILS
TOENAIL
16.CONTINUOUS HEADER TO STUD 4-8d COMMON (212" X 0.131")TOENAIL
3-16d COMMON (312" X 0.162") MINIMUM,
TABLE 2308.10.4.1
4-3" X 0.131"NAILS
17.CEILING JOISTS, LAPS OVER PARTITIONS
(SEE SECTION 2308.10.4.1, TABLE 2308.10.4.1)
FACE NAIL
3-16d COMMON (312" X 0.162") MINIMUM,
TABLE 2308.10.4.1
4-3" X 0.131"NAILS
18.CEILING JOISTS TO PARALLEL RAFTERS
(SEE SECTION 2308.10.4.1, TABLE 2308.10.4.1)
FACE NAIL
3-8d COMMON (212" X 0.131")
3-3" X 0.131" NAILS
19.RAFTER TO PLATE
(SEE SECTION 2308.10.1, TABLE 2308.10.1)
TOENAIL
2-8d COMMON (212" X 0.131")
2-3" X 0.131" NAILS
20.1" DIAGONAL BRACE TO EACH STUD AND PLATE FACE NAIL
21.1" X 8" SHEATHING TO EACH BEARING 3-8d COMMON (212" X 0.131")FACE NAIL
3-8d COMMON (212" X 0.131")FACE NAIL22.WIDER THAN 1" X 8" SHEATHING TO EACH BEARING
16d COMMON (312" X 0.162")
3" X 0.131" NAILS
23.BUILT-UP CORNER STUDS 24" O.C.
16" O.C.
2-20d COMMON (4" X 0.192")
3-3" X 0.131" NAILS
20d COMMON (4" X 0.192") 32"
3" X 0.131" NAIL AT 24" O.C.
24.BUILT-UP GIRDER AND BEAMS FACE NAIL AT TOP AND
BOTTOM STAGGERED ON
OPPOSITE SIDES
FACE NAIL AT ENDS AND
AT EACH SPLICE
25.2" PLANKS 16d COMMON (312" X 0.162")AT EACH BEARING
3-10d COMMON (3" X 0.148")
4-3" X 0.131" NAILS
FACE NAIL26.COLLAR TIE TO RAFTER
2-16d COMMON (312" X 0.162")
3-3" X 0.131" NAILS
3-10d COMMON (3" X 0.148")
4-3" X 0.131" NAILS
FACE NAIL
TOENAIL27.JACK RAFTER TO HIP
28.ROOF RAFTER TO 2-BY RIDGE BEAM 2-16d COMMON (312" X 0.162")
3-3" X 0.131" NAILS
2-16d COMMON (312" X 0.162")
3-3" X 0.131" NAILS
TOENAIL
FACE NAIL
3-16d COMMON (312" X 0.162")
4-3" X 0.131" NAILS
29.JOIST TO BAND JOIST FACE NAIL
3-16d COMMON (312" X 0.162")
4-3" X 0.131" NAILS
30.LEDGER STRIP FACE NAIL
31.WOOD STRUCTURAL PANELS AND
PARTICLEBOARD SUBFLOOR, ROOF AND WALL
SHEATHING (TO FRAMING)
SINGLE FLOOR (COMBINATION
SUBFLOOR-UNDERLAYMENT TO FRAMING)
32.PANEL SIDING (TO FRAMING)
33.FIBERBOARD SHEATHINGG
34.INTERIOR PANELING
12" AND LESS 6d
238" X 0.113" NAIL
1932" TO 34"8d OR 6d
238" X 0.113" NAIL
78" TO 1"8d
118" TO 114"10d OR 8d
B C,L
N
ED
P
E
D D
34" AND LESS 6d
78" TO 1"8d
118" TO 114"10d OR 8d
E
ED
12" OR LESS 6d
58"8d
F
F
12"NO. 11 GAGE ROOFING NAIL
6d COMMON NAIL (2" X 0.113")
2532"NO. 11 GAGE ROOFING NAIL
8d COMMON NAIL (212" X 0.131")
H
H
14"4d
38"6dK
J
I:HANGERS
1.FILL ALL NAIL HOLES PER MANUFACTURER SPECIFICATIONS, FOR MAXIMUM CAPACITY.
2.USE ITS OR IUS HANGERS FOR I-JOIST CONNECTIONS U.N.O. BEND TABS DOWN TO TOP OF BOTTOM CHORD
WHERE APPLICABLE.
3.USE LUS FULL DEPTH HANGERS FOR 2X JOIST CONNECTIONS U.N.O.
4.USE HU FULL DEPTH HANGERS FOR BEAM CONNECTIONS U.N.O.
5.USE LUS HANGERS PER TABLE BELOW FOR ROOF TRUSSES AT 24" O.C. (OR LESS) TO NON-TRUSS FRAMING
MEMBERS:
TRUSS SPAN HANGER
≤ 10'LUS 24
≤ 20'LUS 26
≤ 30'LUS 28
≤ 40'HUS 26
J:MANUFACTURED SHEAR WALLS
1.MANUFACTURED SHEAR WALLS SHALL BE BY SIMPSON STRONG-TIE ( ICC ESR-1679), HARDY FRAMES, INC. (ICC
ESR-2089), OR TRUS JOIST (ICC ESR-1153), AS SPECIFIED ON THE PLANS.
2.ALL MANUFACTURED SHEAR WALLS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS.
3.TEMPLATES SHALL BE USED FOR MANUFACTURED SHEAR WALLS FOR ACCURATE ANCHOR PLACEMENT IN THE
FOUNDATION.
4.FOR HARDY PANELS / BRACED FRAMES - FOLLOW MANUFACTURERS RECOMMENDATIONS FOR MOISTURE
BARRIER PLACED BETWEEN THE WALL AND CONCRETE, GROUT OR MUD SILL.
O:SPECIAL INSPECTIONS
1.PROVIDE SPECIAL INSPECTION WHERE REQUIRED BY SECTION 1704 OF THE CBC. ADDITIONALLY, VERIFY OTHER
AREAS REQUIRING SPECIAL INSPECTION WITH THE BUILDING OFFICIAL OF THE GOVERNING JURISDICTION.
2.INSPECTIONS SHALL CONFORM WITH CBC SECTIONS 110 AND 1704.
3.INSPECTIONS SHALL BE PERFORMED BY QUALIFIED INSPECTORS AND TESTING AGENCIES RETAINED BY THE
OWNER AND NOT THE CONTRACTOR. INSPECTORS AND AGENCIES SHALL BE APPROVED BY THE GOVERNING
JURISDICTION.
4.COPIES OF ALL INSPECTION REPORTS AND TEST RESULTS SHALL BE FURNISHED TO THE OWNER, BUILDING
DEPARTMENT, ARCHITECT, AND ENGINEER. COPIES OF THE REPORTS AND RESULTS SHALL ALSO BE KEPT AT
THE JOB SITE.
5.FINAL REPORT FOR ALL INSPECTIONS AND TESTING, STATING THAT THE WORK WAS COMPLETED IN
ACCORDANCE WITH THE APPROVED PLANS AND ALL APPLICABLE CODES AND STANDARDS, SHALL BE SUBMITTED
TO THE OWNER, BUILDING DEPARTMENT, ARCHITECT, AND ENGINEER.
6.STRUCTURAL OBSERVATION MAY BE REQUIRED BY THE JURISDICTION, ENGINEER, OR OWNER. THESE
OBSERVATIONS DO NOT REPLACE ANY OF THE REQUIRED INSPECTIONS BY DEPUTY INSPECTORS OR THE LOCAL
JURISDICTION.
7.SPECIAL INSPECTION IS REQUIRED FOR THE FOLLOWING WORK:
CONCRETE WITH F'C OVER 2500 PSI
CAST-IN-PLACE DRILLED PILES OR CAISSONS
FIELD WELDING
EPOXY
WELDING OF REINFORCING STEEL
HIGH STRENGTH BOLTING
SHOTCRETE
REINFORCEMENT AND TENDON PLACEMENT IN CONCRETE WITH F'C OVER 2500 PSI
TENDON STRESSING AND GROUTING
TITEN HD SCREW ANCHORS
FASTENERS OF THE SEISMIC FORCE-RESISTING SYSTEM WHERE ITS SPACING IS ≤ 4" O.C.
ADDITIONAL ITEMS REQUIRING SPECIAL INSPECTION MAY BE NOTED ON THE PLANS.
K:WOOD CONNECTORS
1.UNLESS SPECIFICALLY NOTED OTHERWISE, ALL WOOD FRAMING CONNECTORS SHALL BE BY SIMPSON STRONG-TIE.
ALL INSTALLATIONS SHALL FOLLOW CURRENT RECOMMENDATIONS OF SIMPSON.
2.WHERE SIMPSON STRONG-TIE ALLOWS THE USE OF ALTERNATE OR ADDITIONAL FASTENERS, THE FASTENER TYPE
AND AMOUNT RESULTING IN THE HIGHER CAPACITY SHALL BE USED, UNLESS NOTED OTHERWISE.
3.THE NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION SHALL BE FOLLOWED WITH RESPECT TO
FABRICATION AND ASSEMBLY OF ALL FASTENERS, EDGE AND END DISTANCE REQUIREMENTS, AND MINIMUM
PENETRATION REQUIREMENTS.
4.BOLTS, LAG SCREWS, AND WOOD SCREWS SHALL CONFORM TO ASME STANDARD B-18.2.6.
5.ALL HOLES DRILLED FOR BOLTS THROUGH WOOD SHALL BE A MINIMUM OF 132" AND A MAXIMUM OF 116" OVERSIZED.
6.STANDARD CUT WASHERS SHALL BE INSTALLED BETWEEN THE WOOD AND THE NUT FOR ALL BOLT INSTALLATIONS.
7.THE THREADED PORTION OF BOLTS SUBJECT TO WOOD BEARING SHALL BE KEPT TO A PRACTICAL MINIMUM.
8.CARE SHALL BE TAKEN TO CENTER BOLT HOLES IN MAIN MEMBERS.
9.WHEN NAILING A MEMBER CAUSES SPLITTING, THE MEMBER SHALL BE PREDRILLED TO PREVENT THE SPLITTING.
THE DIAMETER OF THE BOLTED HOLE SHALL NOT EXCEED 75% OF THE NAIL DIAMETER.
10.ALL NAILS SHALL CONFORM TO THE NOMINAL SIZES SPECIFIED IN FEDERAL SPECIFICATION FF-N-105B.
11.ALL NAILS EXPOSED TO WEATHER, HEAT, OR MOISTURE SHALL BE GALVANIZED.
12.LEAD HOLES FOR LAG SCREWS SHALL BE BORED AS FOLLOWS:
(A)THE CLEARANCE HOLE FOR THE SHANK SHALL HAVE THE SAME DIAMETER AS THE SHANK, AND THE SAME DEPTH
OF PENETRATION AS THE LENGTH OF UNTHREADED SHANK.
(B)THE LEAD HOLE FOR THE THREADED PORTION SHALL HAVE A DIAMETER EQUAL TO 40% TO 70% OF THE SHANK
DIAMETER IN WOOD AND A LENGTH EQUAL TO AT LEAST THE LENGTH OF THE THREADED PORTION. THE LARGER
PERCENTILE SHALL APPLY TO LAG SCREWS OF 12" OR GREATER DIAMETER.
13.THE THREADED PORTION OF WOOD SCREWS SHALL BE INSERTED IN IT'S LEAD HOLES BY TURNING WITH A
WRENCH, NOT BY DRIVING WITH A HAMMER.
14.DO NOT OVER-TORQUE LAG AND WOOD SCREWS.
15.SOAP OR OTHER LUBRICANT SHALL BE USED ON THE WOOD/LAG SCREW OR IN THE LEAD HOLES TO FACILITATE
INSERTION AND PREVENT DAMAGE TO THE LAG SCREW.
16.WOOD SCREWS LOADED IN WITHDRAWAL MAY BE INSERTED WITHOUT A LEAD HOLE.
17.LEAD HOLES FOR WOOD SCREWS LOADED LATERALLY SHALL BE BORED AS FOLLOWS:
THE PART OF THE LEAD HOLE RECEIVEING THE SHANK SHALL BE ABOUT 78 THE DIAMETER OF THE SHANK AND
THAT RECEIVEING THE THREADED PORTION SHALL BE ABOUT 78 THE DIAMETER OF THE SCREW AT THE ROOT OF
THE THREAD.
18.ALL NAILS SHALL BE DRIVEN SO THAT THEIR HEAD OR CROWN IS FLUSH WITH THE SURFACE BEING NAILED, BUT
DOES NOT PUNCTURE THE SURFACE BEING NAILED.
19.NAIL DEFINITIONS AND PENETRATION (INTO MAIN MEMBER) REQUIREMENTS:
NAIL DIAMETER (IN.)REQUIRED PENETRATION (IN.)
8d COMMON 0.131 1.31
10d COMMON 0.148 1.48
12d COMMON 0.148 1.48
16d SINKER 0.148 1.48
16d COMMON 0.162 1.62
20.FASTENERS IN CONTACT WITH PRESERVATIVE TREATED LUMBER AND FIRE RETARDANT TREATED WOOD SHALL BE
OF HOT-DIPPED GALVANIZED STEEL, ZINC-COATED STEEL, STAINLESS STEEL, SILICON COVERED, BRONZE, OR
COPPER. THE COATING WEIGHTS FOR ZINC-COATED FASTENERS SHALL BE PER ASTM A153. FASTENINGS FOR
WOOD FOUNDATIONS SHOULD BE AS REQUIRED IN AF&PA TECHNICAL REPORT #7. EXCEPTION: PLAIN CARBON
STEEL FASTENERS IN SBX/DOT AND ZINC BORATE PRESERVATIVE-TREATED WOOD IN AN INTERIOR, DRY
ENVIRONMENT SHALL BE PERMITTED. FIELD CUT ENDS, NOTCHES, DRILLED HOLES OF PRESERVATIVE TREATED
WOOD SHALL BE FIELD TREATED PER AWPA M4.
A: GENERAL
1.IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS, GRADE DATUMS, ELEVATIONS,
REQUIRED RETAINING WALLS, DEEPENED FOOTINGS, AND CONDITIONS AT THE JOB SITE PRIOR TO BIDDING AND
START OF CONSTRUCTION. VERIFY ALL DETAILS AND DIMENSIONS OF RELATED REQUIREMENTS ON ALL OTHER
CONSULTANT DRAWINGS WITH STRUCTURAL DRAWINGS FOR ANY CONFLICTS AND NOTIFY THE ENGINEER OF
RECORD AND ARCHITECT OF ANY DISCREPANCIES PRIOR TO START OF CONSTRUCTION.
2.THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ALL OTHER CONSULTANT DRAWINGS. THE
CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION AND VERIFICATION OF ALL WORK.
3.IF A CONFLICT OCCURS WITHIN THE STRUCTURAL DRAWINGS OR WITH ANY OTHER CONSULTANT DRAWINGS,
NOTIFY THE EOR IMMEDIATELY FOR CLARIFICATION OF THE INTENT OF THE CONTRACT DOCUMENTS.
4.DIMENSIONS SHALL NOT BE SCALED FROM STRUCTURAL DRAWINGS.
5.EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE NOTED OR SHOWN ON PLANS OR SPECIFICATIONS, ALL
MATERIALS AND CONSTRUCTION PRACTICES SHALL CONFORM TO THE REQUIREMENTS OF THE ADOPTED
VERSION OF THE CALIFORNIA BUILDING CODE AND ALL APPLICABLE STATE AND LOCAL ORDINANCES AS ADOPTED
BY THE GOVERNING JURISDICTION.
6.THE DESIGN AND SAFETY OF BRACING, SHORING, TEMPORARY SUPPORTS, ETC. IS THE SOLE RESPONSIBILITY OF
THE CONTRACTOR AND NOT WITHIN THE SCOPE OF THE ENGINEER. THAT CONTRACTOR IS RESPONSIBLE FOR
THE STABILITY OF THE STRUCTURE PRIOR TO THE COMPLETION OF THE COMPLETE BUILDING PER PERMITTED
STRUCTURAL PLANS. OBSERVATION VISITS TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT IMPLY THE
ASSUMPTION OF ANY RESPONSIBILITY IN THIS REGARD.
7.ALL DIMENSIONS OF DOORS, OPENINGS, WALLS, ETC. SHALL BE DETERMINED FROM THE ARCHITECTURAL
DRAWINGS, SHOP DRAWINGS, EQUIPMENT DATA, OR DOCUMENTS PROVIDED BY OTHER CONSULTANTS.
8.PENETRATIONS, OPENINGS, SLEEVES, VARIATIONS IN STRUCTURAL SLAB ELEVATIONS, DEPRESSED AREAS,
DEEPENED FOOTINGS, AND ALL OTHER ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND CIVIL
REQUIREMENTS MUST BE COORDINATED BEFORE THE CONTRACTOR PROCEEDS WITH CONSTRUCTION.
9.STRUCTURAL MEMBERS SHALL NOT BE CUT OR NOTCHED UNLESS SPECIFICALLY DETAILED ON THESE PLANS.
10.NO SUBSTITUTION OF STRUCTURAL MEMBERS OR HARDWARE MAY OCCURS UNLESS ALTERNATES ARE
APPROVED IN WRITING BY THE ARCHITECT, OWNER, AND STRUCTURAL ENGINEER.
11.ANY REFERENCE TO THE WORDS "APPROVED" OR "APPROVAL" IN DOCUMENTS SHALL BE DEFINED TO MEAN
GENERAL ACCEPTANCE OR REVIEW AND SHALL NOT RELIEVE THE CONTRACTOR AND HIS SUBCONTRACTORS OF
ANY LIABILITY IN FURNISHING THE REQUIRED MATERIALS OR LABOR SPECIFICATIONS AND COORDINATING THE
REQUIRED MATERIALS OR LABOR SPECIFICATIONS WITH OTHER TRADES.
12.WHERE A DETAIL, SECTION, OR NOTE IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FOR ALL LIKE OR SIMILAR
CONDITIONS UNLESS OTHERWISE NOTED. DETAILS MARKED "TYPICAL" SHALL APPLY IN ALL CASES UNLESS
SPECIFICALLY INDICATED OTHERWISE. WHERE NO SPECIFIC DETAIL IS SHOWN, THE CONSTRUCTION SHALL BE
IDENTICAL OR SIMILAR TO LIKE CASES OF CONSTRUCTION.
13.CONNECTIONS OF ALL ITEMS SUPPORTED BY THE PRIMARY BUILDING STRUCTURE ARE THE RESPONSIBILITY OF
THE DISCIPLINES WHICH MAKE THESE ATTACHMENTS. COORDINATE ALL ATTACHMENTS WITH ARCHITECTURAL
AND STRUCTURAL PLANS.
14.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES, WHETHER
INDICATED ON THE CONTRACT DRAWINGS OR NOT, AND TO PROTECT THEM FROM DAMAGE.
15.VIBRATION EFFECTS OF MECHANICAL AND / OR ANY OTHER EQUIPMENT OR HUMAN ASSEMBLY HAVE NOT BEEN
CONSIDERED BY THE STRUCTURAL ENGINEER.
16.FLOOR SYSTEMS HAVE NOT BEEN DESIGNED FOR EXCESSIVE LOAD CONCENTRATIONS SUCH AS WATER BEDS.
ENGINEER OF RECORD SHALL BE NOTIFIED PRIOR TO CONSTRUCTION IF ANY EXTRAORDINARY HEAVY OBJECTS
ARE TO BE INSTALLED.
17.ALL EXPOSED STEEL OR METAL FASTENERS SHALL BE HOT DIP GALVANIZED OTHERWISE PROTECTED FROM THE
EFFECTS OF WEATHER EXPOSURE.
18.NO CHANGES ARE TO BE MADE TO THESE DRAWINGS AND SPECIFICATIONS WITHOUT THE WRITTEN CONSENT OF
A LICENSED ENGINEER UNDER THE EMPLOYMENT OF JKL STRUCTURAL ENGINEERING, INC.
SEE HANGER CALLOUTS FOR GIRDER TRUSSES
B:FRAMING
1.ALL FRAMING SHALL CONFORM TO THE GRADES AS SET FORTH BY THE W.C.L.I.B. OR W.W.P.A. AND THE CBC. ALL
LUMBER SHALL BEAR THE GRADE STAMP OF AN APPROVED TESTING AGENCY, EXCEPT ARCHITECTURALLY
EXPOSED LUMBER.
2.ALL LUMBER USED FOR STRUCTURAL PURPOSES SHALL BE DOUGLAS FIR LARCH AND COMPLY WITH DOC PS20.
3.ALL WOOD IN CONTACT WITH THE GROUND, A MASONRY OR CONCRETE FOUNDATION WALL, OR SLAB ON GRADE
SHALL BE PRESSURE TREATED IN ACCORDANCE WITH CBC 2304.12.
4.ALL CONVENTIONALLY FRAMED PORTIONS OF THE STRUCTURE SHALL BE BUILT IN ACCORDANCE WITH CBC
SECTION 2308.
5.THE MINIMUM GRADE OF LUMBER SHALL BE AS FOLLOWS, UNLESS NOTED OTHERWISE:
SILL PLATES P.T.D.F. STANDARD AND BETTER
2X4 STANDARD AND BETTER OR STUD GRADE
3X DF-L #2
2X6 TO 2X14 DF-L #2
4X12 OR SMALLER DF-L #2
4X14 OR LARGER DF-L #2
6X AND 8X DF-L #1
6.ALL LUMBER SHALL HAVE MOISTURE CONTENT OF LESS THAN 19% PRIOR TO ENCLOSING WALL AND FLOOR
FRAMING. THREE RANDOM MOISTURE READINGS PER CGBC 4.505.3 SHALL BE PERFORMED AND SUBMITTED TO
THE CITY BUILDING OFFICIAL.
7.NAILING SHALL BE PER CBC TABLE 2304.10.1 UNLESS NOTED OTHERWISE.
8.TIMBER CONNECTORS AND FASTENERS SHALL BE IN ACCORDANCE WITH CBC 2304.10.
9.PRE-DRILL AS REQUIRED TO PREVENT WOOD SPLITTING.
10.PROVIDE 1X6 DIAGONAL LET-IN BRACING AT 25 FEET ON CENTER FOR STUD WALLS NOT FULLY SHEATHED. NAIL
WITH TWO 8d'S PER STUD AND 3-8d'S AT EACH END TO TOP PLATE / SILL PLATE.
11.PROVIDE SINGLE JOIST BELOW NON-BEARING PARTITIONS PARALLEL TO FLOOR FRAMING. PROVIDE DOUBLE
JOISTS BELOW BEARING PARTITIONS PARALLEL TO FLOOR FRAMING, UNLESS NOTED OTHERWISE.
12.WHERE PIPES ARE PLACED IN OR PARTLY IN A PARTITION AND NECESSITATE THE CUTTING OF THE SOLES OR
PLATES, A METAL TIE NOT LESS THAN 0.058" X 1.5" WIDE SHALL BE FASTENED TO EACH PLATE ACROSS AND TO
EACH SIDE OF THE OPENING WITH NOT LESS THAN 6-16D NAILS.
13.ALL STRUCTURAL SHEATHING (PLYWOOD OR OSB) SHALL BE IDENTIFIED WITH THE GRADE TRADEMARK OF APA -
THE ENGINEERED WOOD ASSOCIATION AND SHALL MEET THE REQUIREMENTS OF PRODUCTS STANDARD PS 1-09,
PS2-10 OR APA PRP 108. ALL SHEATHING WHICH HAS ANY EDGE OR SURFACE PERMANENTLY EXPOSED TO THE
WEATHER SHALL BE OF THE EXTERIOR TYPE. SPAN RATING SHALL NEVER BE LESS THAN THE ON CENTER
SPACING OF SUPPORTS. SHEATHING LESS THAN 24 INCHES IN ANY DIMENSION SHALL NOT BE USED IN
STRUCTURAL APPLICATIONS. SPACING OF 1/8" IS RECOMMENDED AT PANEL ENDS AND EDGES.
ROOF SHEATHING:
19/32" APA RATED SHEATHING, EXP 1, 32/16 SPAN RATING WITH 8d COMMON @ 6" O.C. AT SHEATHING EDGES
AND 12" O.C. AT INTERMEDIATE SUPPORTS. LAY SHEATHING WITH FACE GRAIN OR STRENGTH AXIS
PERPENDICULAR TO SUPPORTS AND CONTINUOUS OVER TWO OR MORE SPANS.
FLOOR / DECK SHEATHING:
23/32" APA RATED STURD-I-FLOOR SHEATHING, EXP 1, WITH MINIMUM SPAN RATING OF 24" O.C. SHEATHING
SHALL BE GLUED PER APA AFG-01 OR ASTM D3498 AND NAILED WITH 10d COMMON (OR 10d RING SHANK /
SCREW SHANK) @ 6" O.C. AT SHEATHING EDGES AND 12" O.C. AT INTERMEDIATE SUPPORTS. SIMPSON
QUICK DRIVE SCREWS (ER-1472) MAY BE SUBSTITUTED FOR THE 10d COMMON NAILING. LAY SHEATHING
WITH FACE GRAIN OR STRENGTH AXIS PERPENDICULAR TO SUPPORTS AND CONTINUOUS OVER TWO OR
MORE SPANS. USE ADHESIVE MEETING APA SPECIFICATION AFG-01 OR ASTM D-3498, APPLIED IN
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
P:STRUCTURAL OBSERVATION
1.STRUCTURAL OBSERVATION MEANS THE VISUAL OBSERVATION OF THE VISIBLE STRUCTURAL SYSTEM, FOR
GENERAL CONFORMANCE TO THE APPROVED PLANS AND SPECIFICATIONS, AT SIGNIFICANT CONSTRUCTION
STAGES AND AT COMPLETION OF THE STRUCTURAL SYSTEM.
2.STRUCTURAL OBSERVATION DOES NOT INCLUDE OR WAIVE THE RESPONSIBILITY FOR THE INSPECTIONS REQUIRED
BY CBC SECTION 110, 1704, OR OTHER SECTION OF THE APPLICABLE CODE AND APPROVED PLANS.
3.STRUCTURAL OBSERVATION IS REQUIRED AT THE FOLLOWING SIGNIFICANT STAGES OF CONSTRUCTION:
A.FOUNDATION GEOMETRY, HARDWARE AND REBAR PRIOR TO POURING OF CONCRETE.
B.STRUCTURAL FRAMING PRIOR TO COVERING OR INSULATION.
4.THE OWNER SHALL EMPLOY THE ENGINEER OF RECORD OR HIS DESIGNEE TO PERFORM STRUCTURAL
OBSERVATION.
5.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING STRUCTURAL OBSERVATIONS WITH JKL STRUCTURAL,
INC. A MINIMUM OF 3 BUSINESS DAYS ADVANCE NOTICE IS REQUIRED TO SCHEDULE OBSERVATIONS.
MANUFACTURER ILEVEL LOUISIANA PACIFIC BOISE CASCADE ROSEBURG
ICC-ES REPORT ESR-1153 ESR-1305 ESR-1336 ESR-1251
DEPTH
1178"
14"/16"
TJI 210 LPI 36 BCI 6000-1.7 RFPI-400
TJI 360 LPI 56 BCI 60-2.0 RFPI-70
TJI 560 -BCI 90-2.0 RFPI-90
LPI 32 PLUS
LPI 56
-
TJI 210
TJI 360
TJI 560
BCI 6000-1.8
BCI 60-2.0
-
RFPI-400
RFPI-70
RFPI-90
TYP. ROOF & FLOOR SHEATHING LAYOUT
WALL SHEATHING SHALL BE INSTALLED
PERPENDICULAR TO FRAMING MEMBERS
W/ GLUE PER APA AFG-01 OR ASTM D3498
BN AT ALL
SHEATHING
EDGES (MIN 38" EDGE DISTANCE)
OFFSET SECOND ROW
OF SHEATHING BY LENGTH
OF ONE PANEL
FIELD NAILING
ADD BLKG. AT
BLOCKED DIAPHRAGMS
EN TO MATCH BN
FRAMING MEMBERS
H:ENGINEERED LUMBER
1.FOLLOW ALL MANUFACTURER RECOMMENDATIONS FOR DRILLING, NOTCHING, HANDLING, STORAGE, BRACING,
AND ERECTION OF PREFABRICATED FRAMING MEMBERS.
2.1.25" AND 1.5" WIDE LSL RIM MANUFACTURERS (AND APPROVAL REPORTS) ARE: TRUS JOIST (ICC ESR-1387). LSL
RIMS SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES: SPECIFIC GRAVITY = 0.5; E = 1,300,000 PSI; Fb = 1,700
PSI; Fcperp = 680 PSI; Fv = 400 PSI; AND VERTICAL LOAD CAPACITY = 4250 PLF
3.LSL BEAMS (1.75" AND WIDER) MANUFACTURER (AND APPROVAL REPORTS) ARE: TRUS JOIST (ICC ESR-1387). LSL
BEAMS SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES: SPECIFIC GRAVITY = 0.5; E = 1,550,000 PSI; Fb =
2,325 PSI; Fcperp = 800 PSI; AND Fv = 400 PSI.
4.ML BEAM MANUFACTURER (AND APPROVAL REPORTS) ARE: TRUS JOIST MICROLLAM (ICC ESR-1387), BOISE
CASCADE VERSALAM (ICC ESR-1040), AND LOUSIANA PACIFIC LPLVL (ICC ESR-1254). ML BEAMS SHALL HAVE THE
FOLLOWING MINIMUM PROPERTIES: SPECIFIC GRAVITY = 0.5; E = 1,900,000 PSI; Fb = 2,600 PSI; Fcperp = 750 PSI;
AND Fv = 285 PSI.
5.PSL BEAM MANUFACTURER (AND APPROVAL REPORTS) ARE: TRUS JOIST PARALLAM (ICC ESR-1387). PSL BEAMS
SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES: SPECIFIC GRAVITY = 0.5; E = 2,000,000 PSI; Fb = 2,900 PSI;
Fcperp = 750 PSI; AND Fv = 290 PSI.
6.I-JOIST MANUFACTURERS (AND APPROVAL REPORTS) ARE: ILEVEL (ICC ESR-1153); LOUSIANA PACIFIC (ICC
ESR-1305); BOISE CASCADE (ICC ESR-1336), ROSEBURG (ICC ESR-1251). SEE TABLE BELOW FOR ALLOWABLE
JOIST SUBSTITUTIONS.
G:GLUED-LAMINATED BEAMS
1.GLUED LAMINATED BEAMS SHALL CONFORM TO THE "AMERICAN NATIONAL STANDARD FOR STRUCTURAL GLUED
LAMINATED TIMBER", AITC / APA-EWS 117, ANSI / AITC A-190.1 AND ALL APPROVED SUPPLEMENTS THEREOF.
2.INDIVIDUAL LAMINATIONS SHALL NOT EXCEED 2" IN THICKNESS.
3.SIMPLE SPAN BEAMS SHALL BE DOUGLAS FIR 24F V-4 AND CANTILEVER SPANS SHALL BE DOUGLAS FIR 24F V-8.
4.WHERE SIZES OF 318" WIDE OR 518" WIDE ARE SPECIFIED, WIDTHS OF 3.5" AND 5.5", RESPECTIVELY, MAY BE
SUBSTITUTED.
5.BEAMS SHALL BEAR A LEGIBLE APA-EWS OR AITC GRADE STAMP.
6.APPROVED INSPECTION CERTIFICATES SHALL BE SUBMITTED TO THE BUILDING INSPECTOR OR BUILDING
DEPARTMENT PRIOR TO ERECTION. CERTIFICATES SHALL INCLUDE THE QUALITY CONTROL INSPECTION DATA.
7.END OF BEAMS SHALL BE SEALED AND BEAMS SHALL BE LOAD WRAPPED FOR PROTECTION PRIOR TO
CONSTRUCTION. STORAGE OF GLB'S SHALL COMPLY WITH AITC 111-79.
8.GLB'S PERMANENTLY EXPOSED TO WEATHER OR MOISTURE SHALL BE FACTORY PRESSURE TREATED.
9.ALL GLB'S BEAMS SHALL HAVE STANDARD CAMBER (RADIUS OF 3,500 FEET), UNLESS NOTE OTHERWISE.
10.MOISTURE CONTENT IN SERVICE SHALL BE BETWEEN 8% AND 12%.
11.BEAMS SHALL CONFORM TO APA-EWS OR AITC FRAMING OR INDUSTRIAL GRADE APPEARANCE, UNLESS NOTED
OTHERWISE.
12.REFER TO ARCHITECTURAL PLANS FOR FINISH OF ARCHITECTURALLY EXPOSED GLB'S (ARCHITECTURAL OR
PREMIUM GRADE APPEARANCE CLASSIFICATION).
13.GLB'S SHALL MEET THE FOLLOWING MINIMUM ALLOWABLE STRESS REQUIREMENTS:
FLEXURAL STRESS 2,400 PSI
TENSION PARALLEL TO GRAIN 1,100 PSI
COMPRESSION PARALLEL TO GRAIN 1,650 PSI
HORIZONTAL SHEAR PERP. TO WIDE FACE 240 PSI
MODULUS OF ELASTICITY 1,800,000 PSI
COMPRESSION PERP TO GRAIN 650 PSI
F:REBAR
1.ALL REBAR SHALL CONFORM TO ASTM A-615 (GRADE 40 FOR SIZES #3 AND #4; GRADE 60 FOR SIZES #5 AND
LARGER).
2.WELDED WIRE MESH / FABRIC SHALL CONFORM TO ASTM A-185 (GRADE 65) AND BE LAPPED 1.5 SPACES (12"
MINIMUM) FOR PLAIN WIRE AND ASTM A-497 (GRADE 75) FOR DEFORMED BAR.
3.REINFORCING STEEL TO BE WELDED SHALL CONFORM TO ASTM A-706.
4.DETAILS OF REINFORCING SHALL CONFORM TO THE CURRENT ACI CODE.
5.REINFORCING BAR BENDS SHALL BE BENT COLD.
6.WELDING OF REINFORCEMENT SHALL BE IN ACCORDANCE WITH AWS D1.4. USE LOW HYDROGEN ELECTRODES
AND PREHEAT. NO WELDING SHALL BE DONE AT THE BEND IN A BAR.
7.SPLICES OF HORIZONTAL BARS IN WALLS AND FOOTINGS SHALL BE STAGGERED AT LEAST 48" MINIMUM.
D:CONCRETE
1.CONCRETE MIXES SHALL BE DESIGNED BY A RECOGNIZED TESTING LABORATORY AND SHALL BE STAMPED AND
SIGNED BY A LICENSED CIVIL OR STRUCTURAL ENGINEER.
2.THE CONCRETE SUPPLIER SHALL BEAR THE RESPONSIBILITY THAT THE MIX DESIGN WILL ATTAIN THE REQUIRED
SPECIFIED STRENGTH AND SHRINKAGE CHARACTERISTICS.
3.CEMENT SHALL BE PORTLAND CEMENT CONFORMING TO ASTM C-150 TYPE II. SEE SOILS REPORT FOR SULFATE
CONTENT. WHERE SEVERE OR VERY SEVERE SULFATE EXPOSURE EXISTS, TYPE V CEMENT SHALL BE USED AND
CONCRETE MIX SHALL CONFORM TO THE REQUIREMENTS OF ACI 318-14 TABLE 19.3.1.1 AND 19.3.2.1
4.MAXIMUM SLUMP OF NORMAL WEIGHT CONCRETE SHALL NOT EXCEED 4".
5.READY MIX CONCRETE SHALL BE MIXED AND DELIVERED IN ACCORDANCE WITH ASTM C-94.
6.AGGREGATES FOR NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C-33.
7.AGGREGATES FOR LIGHT WEIGHT CONCRETE SHALL CONFORM TO ASTM C-330.
8.THE MINIMUM ULTIMATE COMPRESSIVE STRENGTH AT 28 DAYS SHALL BE 4000 PSI UNLESS OTHERWISE NOTED.
9.SPECIAL INSPECTION IS REQUIRED ON CONCRETE WORK WHERE THE SPECIFIED ULTIMATE COMPRESSIVE
DESIGN STRENGTH EXCEEDS 2500 PSI.
10.REFER TO REQUIREMENTS IN ACI 318-14 TABLES 19.3.1.1, 19.3.2.1, & 19.3.3.1 FOR CONCRETE EXPOSED TO FROST,
DEICING CHEMICALS, SULFATE, CORROSION, OR OTHER SPECIAL EXPOSURE CONDITIONS.
11.FORMS SHALL BE REMOVED IN SUCH A MANNER AS NOT TO IMPAIR SAFETY AND SERVICEABILITY OF THE
STRUCTURE. CONCRETE TO BE EXPOSED BY FORM REMOVAL SHALL HAVE SUFFICIENT STRENGTH NOT TO BE
DAMAGED BY REMOVAL OF FORMS.
C:SUBGRADE AND FOUNDATION
1.THE FOUNDATION DESIGN IS BASED UPON THE GEOTECHNICAL REPORT REFERENCED IN THE DESIGN CRITERIA
SECTION OF THIS SHEET. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FOLLOWING ALL REQUIREMENTS SET
FORTH BY THE REFERENCED GEOTECHNICAL REPORT AND MAINTAIN A COPY ON THE JOB SITE AT ALL TIMES.
2.THE GEOTECHNICAL REPORT IN ITS ENTIRETY SHALL BE MADE A PART OF THE CONTRACT DOCUMENTS.
3.THE ENGINEER OF RECORD SHALL BE INFORMED OF ANY CHANGES IN DESIGN CRITERIA MADE BY THE SOIL
ENGINEER IN THE COURSE OF CONSTRUCTION.
4.ALL FOOTINGS AND SLABS SHALL BE FOUNDED ON COMPACTED FILL APPROVED BY THE GEOTECHNICAL
ENGINEER. CONTRACTOR SHALL PROVIDE BUILDING INSPECTOR WITH COMPACTION REPORTS AND WRITTEN
APPROVAL OF COMPACTED FILL FROM THE GEOTECHNICAL ENGINEER FOR ALL REQUIRED FILL.
5.ALL COMPACTED FILL SHALL BE PLACED IN AN APPROVED MANNER WITH A MINIMUM RELATIVE COMPACTION OF
90% IN ACCORDANCE WITH ASTM D-1557.
6.THE GEOTECHNICAL ENGINEER SHALL INSPECT AND APPROVE ALL FOUNDATION EXCAVATIONS, FILLING, BACK
FILLING, AND BUILDING PADS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SHORING NECESSARY TO
SUPPORT CUT AND/OR FILL SECTIONS DURING EXCAVATION, AND SHORING FOR FORMING AND PLACEMENT OF
CONCRETE.
7.THE GEOTECHNICAL ENGINEER SHALL INSPECT AND APPROVE ALL FOUNDATION TRENCHES PRIOR TO CALLING
FOR CITY FOUNDATION INSPECTION AND PLACING REINFORCING AND/OR CONCRETE. THE CONTRACTOR SHALL
SUBMIT THE GEOTECHNICAL ENGINEER'S WRITTEN APPROVAL OF THE FOUNDATION TRENCHES TO THE CITY
BUILDING INSPECTOR.
8.ALL RETAINING WALLS HAVE BEEN DESIGNED FOR A FREE DRAINING CONDITION. DESIGN OF THE DRAINAGE
SYSTEM SHALL BE BY OTHERS AND SHALL MEET THE REQUIREMENTS OF THE SOILS REPORT. BACK FILL AGAINST
WALLS SHALL BE PLACED EVENLY AGAINST BOTH SIDES OF WALLS UNTIL THE LOWER GRADE IS REACHED.
BACKFILL SHALL BE ACCOMPLISHED IN SUCH A MANNER AS TO NOT CAUSE A SURCHARGE ON THE RETAINING
WALL.
9.SOIL CORROSIVENESS SHALL BE DETERMINED BY THE GEOTECHNICAL ENGINEER. WHERE REQUIRED,
MITIGATION MEASURES FOR CORROSIVE SOILS SHALL BE PROVIDED BY A GEOTECHNICAL ENGINEER, CORROSION
ENGINEER, OR OTHER EXPERT IN THE MITIGATION MEASURES.
E:CONCRETE MASONRY
1.ALL CONCRETE MASONRY MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH CBC CHAPTER 21.
2.CONCRETE MASONRY UNITS SHALL CONFORM ASTM C-90. CONCRETE BRICK SHALL CONFORM TO ASTM C55,
SPECIFICATIONS FOR CONCRETE BUILDING BRICK.
3.SOLID GROUT ALL CELLS UNLESS NOTED OTHERWISE.
4.CLEANOUTS REQUIRED AT THE BOTTOM OF ALL CELLS TO BE FILLED FOR POURS EXCEEDING 4 FEET IN HEIGHT.
5.MORTAR SHALL BE TYPE M OR S AS APPLICABLE AND CONFORMING WITH ASTM C270 AND SHALL BE
PROPORTIONED PER ARTICLE 2.1 & 2.6A OF SPECIFICATION FOR MASONRY STRUCTURES (TMS 602-16/ACI
530.1-16/ASCE 6-16).
6.GROUT SHALL COMPLY WITH ARTICLE 2.2 & 2.6B OF TMS 602-16/ACI 530.1-16/ASCE 6-16 AND SHALL ATTAIN A
MINIMUM COMPRESSION STRENGTH AT 28 DAYS OF 2000 PSI OR THE REQUIRED COMPRESSION, F'M, WHICHEVER
IS GREATER. THE COMPRESSIVE STRENGTH OF GROUT SHALL BE DETERMINED IN ACCORDANCE WITH ASTM
C-1019.
7.GROUT SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI AT 28 DAYS.
8.GRADE N CONCRETE BRICKS SHALL BE USED AS ARCHITECTURAL VENEER AND GRADE S CONCRETE BRICKS
SHALL BE FOR GENERAL USE AND RESISTANCE TO FROST AND MOISTURE PENETRATION IS REQUIRED.
N:WELDING
1.A WELDING PROCEDURE SPECIFICATION (WPS) PER AWS D1.1 SHALL BE DEVELOPED BY THE
FABRICATOR/ERECTOR AND SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL. THE WPS
SHALL INCLUDE THE WELDING PARAMETERS RECOMMENDED BY THE ELECTRODE MANUFACTURER.
2.WELDING OF STRUCTURAL STEEL SHALL CONFORM TO AWS D1.1 USING APPROVED E70XX ELECTRODES.
3.ALL WELDING SHALL BE PERFORMED BY AN EXPERIENCED, CERTIFIED WELDER FOR THE TYPE OF WELD BEING
MADE.
4.TO ASSURE THE PROPER AMPERAGE AND VOLTAGE OF THE WELDING PROCESS, A HAND HELD CALIBRATED AMP
AND VOLT METER SHALL BE USED BY THE FABRICATOR, ERECTOR, AND INSPECTOR. AMPERAGE AND VOLTAGE
SHALL BE MEASURED NEAR THE ARC. TRAVEL SPEED AND ELECTRODE STICK OUT SHALL BE VERIFIED TO BE IN
COMPLIANCE WITH THE APPROVED WELDING PROCEDURE SPECIFICATION.
5.WELD LENGTHS CALLED FOR ON THE PLANS ARE NET EFFECTIVE WELD LENGTHS.
6.ALL FIELD WELDING SHALL BE CONTINUOUSLY INSPECTED BY A SPECIAL INSPECTOR QUALIFIED IN WELDING.
FIELD WELDING SHALL BE INDICATED ON THE SHOP DRAWINGS.
7.ALL SHOP WELDING SHALL BE CONTINUOUSLY INSPECTED BY A SPECIAL INSPECTOR QUALIFIED IN WELDING
UNLESS IT IS PERFORMED BY A LICENSED FABRICATOR APPROVED BY THE GOVERNING JURISDICTION.
8.SURFACES ON WHICH WELDS WILL BE DEPOSITED SHALL BE SMOOTH, UNIFORM, FREE FROM FINS, TEARS,
CRACKS, AND OTHER DISCONTINUITIES WHICH WOULD ADVERSELY AFFECT THE STRENGTH, DUCTILITY, OR
OTHER QUALITY OF THE WELD.
9.WELD SIZES NOT SPECIFIED SHALL BE CONTINUOUS FILLET WELDS WITH SIZES BASED ON AISC TABLE J2.4.
10.GRIND SMOOTH ALL EXPOSED WELDS TO AN APPEARANCE ACCEPTABLE BY THE ARCHITECT.
11.PARTIAL AND FULL PENETRATION GROOVE WELDS SHALL HAVE NON-DESTRUCTIVE (ULTRASONIC OR
RADIOGRAPHIC) TESTING PERFORMED. THE RATE OF TESTING SHALL BE 100% BUT MAY BE REDUCED AS
ALLOWED BY AWSD1.1.
12.STRUCTURAL STEEL FRAMING MEMBERS SHALL BE SUPPORTED DURING FIELD WELDING. SUPPORTS SHALL
REMAIN IN PLACE UNTIL STEEL TEMPERATURE HAS RETURNED TO AIR TEMPERATURE.
13.BOLTS, NUT, AND RODS SHALL NOT BE WELDED OR HEATED EXCEPT FOR A36 AND A307 AND THOSE ONLY WITH
THE APPROVAL OF THE ENGINEER OF RECORD.
14.STRUCTURAL STEEL SHALL NOT BE TACK WELDED TO REINFORCEMENT IN ANY WAY.
15.FOR WELDING AT PRIMARY MEMBERS AND CONNECTIONS OF THE SEISMIC FORCE RESISTING SYSTEM (BRACED
FRAMES, MOMENT FRAMES, DRAG CONNECTIONS, CHORD MEMBERS, ETC.) THE WELDING FILLER METAL SHALL
HAVE CHARPY V-NOTCH (CVN) TOUGHNESS OF 20 FOOT POUNDS AT MINUS 20 DEGREES FAHRENHEIT AND 40
FOOT POUNDS AT 70 DEGREES FAHRENHEIT (E70T4 IS PROHIBITED).
M:STRUCTURAL STEEL
1.ALL STRUCTURAL STEEL MATERIALS AND CONSTRUCTION SHALL CONFORM TO THE LATEST EDITION OF THE AISC
MANUAL OF STEEL CONSTRUCTION AND CODE OF STANDARD PRACTICE AND CHAPTER 22 OF THE BUILDING
CODE.
2.STRUCTURAL STEEL MEMBERS SHALL CONFORM TO THE FOLLOWING MATERIAL SPECIFICATIONS:
WIDE FLANGE MEMBERS A-992
CONTINUITY, SHEAR, & DOUBLER PLATES A-572
HSS TUBES A-500, GRADE B
STRUCTURAL PIPES A-53, TYPE E OR S, GRADE B
ALL OTHER SHAPES A-36
HIGH STRENGTH BOLTS A-325, SLIP CRITICAL
ANCHOR RODS F-1554, GRADE 36
TYPICAL BOLTS A-307
3.A-992 OR A-572 (GRADE 50) MATERIAL MAY BE SUBSTITUTED FOR A-36 MATERIAL AT CONTRACTOR'S OPTION.
4.STRUCTURAL STEEL DELIVERED TO THE JOB SITE SHALL BE FREE OF EXCESSIVE RUST, DIRT, GREASE, ETC.
5.ALL STEEL FABRICATION SHALL BE PERFORMED IN A SHOP APPROVED BY THE BUILDING DEPARTMENT. SHOP
AND ERECTION DRAWINGS SHALL CONTAIN ALL INFORMATION NECESSARY TO ERECT ALL STRUCTURAL STEEL IN
THE FIELD WITHOUT REFERRING TO THE STRUCTURAL DRAWINGS.
6.STUD ANCHORS SHALL BE NELSON STUD ANCHORS AND SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS. PROVIDE ½" STUD ANCHORS AT 32" O.C. AT ALL LOCATIONS WHERE
ATTACHMENT OF ARCHITECTURAL FINISHES REQUIRES THE USE OF SUCH ANCHORS.
7.INSTALLATION AND INSPECTION OF HIGH STRENGTH BOLTS SHALL CONFORM TO THE REQUIREMENTS OF THE
AISC SPECIFICATIONS FOR STRUCTURAL JOINTS. ASSEMBLE WITH HARDENED WASHERS UNDER THE NUT OR
BOLT HEAD, WHICHEVER IS THE ELEMENT USED IN TIGHTENING. CONTACT FACES AT CONNECTIONS WHERE HIGH
STRENGTH BOLTS ARE USED SHALL BE FREE OF ALL DEBRIS OR OTHER MATERIALS WHICH PREVENT A SOLID
CONNECTION.
8.ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) SHALL CONFORM TO SECTION 10 OF THE AISC CODE OF
STANDARD PRACTICE. REFER TO THE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND ADDITIONAL
APPEARANCE AND TOLERANCE REQUIREMENTS. GRIND SMOOTH ALL EXPOSED WELDS TO AN APPEARANCE
ACCEPTABLE BY THE ARCHITECT. REMOVE ALL TEMPORARY ERECTION CLIPS.
9.ALL STEEL SHALL BE PROTECTED AGAINST RUST EITHER BY PERMANENT ENCASEMENT, RUST INHIBITIVE PRIMER,
HOT DIP GALVANIZATION, ETC. BASED ON THE EXPECTED EXPOSURE AND RISK OF DETERIORATION.
10.PENETRATIONS OR OPENINGS SHALL NOT BE MADE IN STEEL MEMBERS UNLESS SHOWN ON APPROVED
STRUCTURAL PLANS. STEEL MEMBERS SHALL BE SHORED WHEN PERMISSIBLE HOLES ARE CUT WITH A TORCH
AFTER STEEL IS ERECTED. SUPPORTS SHALL REMAIN IN PLACE UNTIL STEEL TEMPERATURE HAS RETURNED TO
AIR TEMPERATURE.
11.STRUCTURAL STEEL SHALL BE PROTECTED AS REQUIRED CHAPTER 7 OF THE CBC AS DETERMINED BY THE
ARCHITECT. SEE ARCHITECTURAL DRAWINGS FOR FIRE PROTECTION REQUIREMENTS.
12.ALL EXPOSED ENDS OF STEEL MEMBERS SHALL BE CAPPED WITH A ¼" CAP PLATE UNLESS NOTED OTHERWISE
PER THE ARCHITECTURAL DRAWINGS.
13.LIGHT GAGE COLD FORMED STEEL MEMBERS SHALL CONFORM TO ASTM A-441.
14.ALL GROUT UNDER BASE PLATES SHALL BE SOLID DRY PACK OR NON-SHRINK GROUT PLACED AS DIRECTED BY
THE MANUFACTURER AND BE OF COMPRESSIVE STRENGTH EQUAL TO OR GREATER THAN THE CONCRETE OR
MASONRY SUPPORTING IT (4000 PSI MIN).
JOB NUMBER:
ENGINEER:
DRAFTER:
ORIGINAL ISSUE:
4-
U
N
I
T
C
O
N
D
O
M
I
N
I
U
M
43
G
E
N
O
A
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
21153
JL
JL
03/11/2022
1
PLAN CHECK COMMENTS
06/26/2022 JL
2
PLAN CHECK COMMENTS
5/17/2023 JL
JKLSTRUCTURAL@GMAIL.COM
(626)524-2210
THE ENGINEER EXPRESSLY RESERVES HIS COMMON LAW
COPYRIGHT IN THESE PLANS. THESE PLANS ARE NOT TO
BE REPRODUCED, CHANGED, OR COPIED IN ANY MANNER
WHATSOEVER, NOR ASSIGNED TO ANY OTHER THIRD
PARTY WITHOUT THE EXPRESSED WRITTEN CONSENT OF
JKL ENGINEERING, INC.
SD0
ST
R
U
C
T
U
R
A
L
S
P
E
C
I
F
I
C
A
T
I
O
N
S
SPECIAL INSPECTIONS
SPECIAL INSPECTION:
1. IN ADDITION TO THE REGULAR INSPECTION THE FOLLOWING ITEMS WILL ALSO REQUIRE SPECIAL INSPECTION IN
ACCORDANCE WITH SEC.1704, UNLESS EXEMPTED BY THE EXCEPTIONS OF SEC.1704.2, OF THE BUILDING CODE
2. SOILS COMPLIANCE PRIOR TO THE FOUNDATION INSPECTION, POST-TENSIONED FOUNDATION, HIGH STRENGTH STEEL
AND CONCRETE.
3. ALL INSPECTIONS AND TESTS SHALL BE PERFORMED BY A QUALIFIED TESTING AGENCY RETAINED BY THE OWNER.
4. THE SPECIAL INSPECTOR SHALL BE QUALIFIED AND APPROVED BY THE BUILDING DEPARTMENT AND ACCEPTABLE TO
THE ARCHITECT.
5. THE SPECIAL INSPECTOR SHALL OBSERVE WORK ASSIGNED FOR CONFORMANCE TO THE APPROVED DESIGN DRAWINGS
AND SPECIFICATIONS.
6. THE SPECIAL INSPECTOR SHALL FURNISH AN INSPECTION REPORT TO THE BUILDING DEPARTMENT, ENGINEER AND
ARCHITECT OF RECORD. COPIES OF THE REPORT SHALL BE AVAILABLE AT THE JOB SITE AT ALL TIMES.
7. FINAL REPORTS FOR ALL INSPECTIONS AND TESTING MUST BE PROVIDED BY THE SPECIAL INSPECTOR. FINAL REPORTS
SHALL DOCUMENT COMPLETION OF ALL INSPECTIONS AND CORRECTION OF ALL NOTED DISCREPENCIES.
8. THE DUTIES OF THE SPECIAL INSPECTOR SHALL BE IN CONFORMANCE WITH THE REQUIREMENTS OF SECTION 1704 OF
THE LATEST EDITION OF THE CBC.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXPENSES DUE TO ANY PREMATURE NOTIFICATION OF INSPECTION
WHICH RESULTS IN ADDITIONAL SITE VISITS.
10. FAILURE OF NOTIFICATION BY THE CONTRACTOR FOR INSPECTION ON A TIMELY BASIS MAY RESULT IN COMPLETE
REMOVAL AND REPLACEMENT OF ALL WORK PERFORMED AT CONTRACTORS EXPENSE.
11. SITE VISITS BY THE STRUCTURAL ENGINEER DO NOT CONSTITUTE AN INSPECTION.
SPECIAL INSPECTION TABLE FOR
STEEL STRUCTURES
FOR THE CONSTRUCTION OF STEEL ELEMENTS OF BUILDING & STRUCTURES, ITEMS
OF SPECIAL INSPECTION & VERIFICATIONS BY A SPECIAL INSPECTOR
ARE REQUIRED & SUMMARIZED IN THE FOLLING TABLE:
VERIFICATION
& INSPECTION
1. Manufacturer's certifications
available for fastener materials.
SPECIAL INSPECTION TABLE FOR
STEEL STRUCTURES
Quality Assurance Reference
Standard
AISC 360-16
TABLE N5.6-1
2. Fasteners marked in accordance
with ASTM requirements.
3. Correct fasteners selected for
the joint detail (grade, type, bolt
length if threads are to be
excluded from shear plane).
4. Correct bolting procedure
selected for joint detail.
7. Protected storage provided for
bolts, nuts, washers and other
fastener components.
Performed Observed
5. Connecting elements, including
the appropriate faying surface
condition and hole preparation,
if specified, meet applicable
requirements.
6. Pre-installation verification
testing by installation personnel
observed and documented for
fastener assemblies and
methods used.
1. Fastener assemblies placed in
all holes and washers and nuts
are positioned as required.
AISC 360-16
TABLE N5.6-2
2. Joint brought to the snug-tight
condition prior to the
pretensioning operation.
3. Fastener component not turned
by the wrench prevented from
rotating.
4. Fasteners are pretensioned in
accordance with the RCSC
Specification, progressing
systematically from the most
rigid point toward the free
edges.
TASKS PRIOR TO BOLTING
TASKS DURING BOLTING
1. Document acceptance or
rejection of bolted connections.
AISC 360-16
TABLE N5.6-3
TASKS AFTER BOLTING
TYPE
INSPECTION
TASK Continuous Periodically SECTION
Sec. 1705.12.2
Sec. 1705.12.2
Sec. 1704
Sec. 1705.12.2
Sec. 1705.12.3
1. Verify materials below footings are
adequate to achieve the design
bearing capacity per soils report.
2. Verify excavations are extended to
proper depth & have reached
proper material per soils report.
3. Perform classification & testing of
compacted fill materials per soils
report.
4. Verify use of proper materials,
densities & lift thicknesses during
placement & compaction of
compacted fill per soils report.
5. Prior to placement of compacted fill,
inspect subgrade & verify that site
has been prepared properly per
soils report.
Exception:
Special inspection is not required
during placement of controlled fill
having a total depth of 12 inches or
less.
Horizontal wood
diaphragms with
edge nail spacing
equal to or closer
than 4" o.c.
Wood shear walls
with edge nail
spacing equal to or
closer than 4" o.c.
Sheathing types,
grade thickness,
span rating, and nail
types, nail sizes &
spacing.
Sheathing types,
grade thickness, wall
nail types, nailing
sizes and spacing.
Sill nail types, size
and spacing.
Anchor bolt sizes &
spacing.
Holdown types &
their connections to
shear walls &
foundation/framing
Wall end post sizes.
Shear transfer
connector types &
spacing. Drag strut
connections to shear
walls.
Panel types, nailing,
bolting, Anchoring,
wall top plate screw
types, sizes &
spacing, holddown &
drag strut
connections to
walls/panels.
Manufactured shear
walls, Hardy panels,
Simpson steel &
Wood Strong walls.
SPECIAL INSPECTION BY A SPECIAL INSPECTOR FOR EXISTING SITE SOIL CONDITIONS,
FILL PLACEMENT & LOAD BEARING REQUIREMENTS SHALL BE PERFORMED PER THE
FOLLOWING TABLE.
SPECIAL INSPECTION TABLE FOR EXISTING SITE
SOIL CONDITIONS
SPECIAL INSPECTION BY A SPECIAL INSPECTOR FOR THE CONSTRUCTION OF
HORIZONTAL WOOD DIAPHRAGMS, WOOD SHEAR WALLS & MANUFACTURED SHEAR
WALLS ARE REQUIRED & SPECIFIED IN THE FOLLOWING TABLE:
SPECIAL INSPECTION TABLE FOR WOOD *
DIAPHRAGM & SHEAR WALLS
Periodic
Special Inspection
Continuous
Special Inspection
REFERENCE
FOR CRITERIA
FREQUENCY OF
INSPECTIONNOT
APPLICABLE
Exception: Special inspection for existing site soil condtions per table below is not required if
allowable soil bearing pressure used for design is ≤ 1500 psf, soils report is not required
by building offical, and there is no controlled fill placement on existing building site
CBC/IBC
EXCEPTION: CONCRETE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME WOOD
BUILDING OF 3-STORIES OR LESS AND THE STRUCTURAL DESIGN OF FOOTINGS IS
BASED ON A SPECIFIED COMPRESSIVE STRENGTH f'c NO GREATER THAN 2500 psi.
SPECIAL INSPECTION TABLE FOR
CONCRETE CONSTRUCTION
SPECIAL INSPECTIONS AND VERIFICATIONS BY A SPECIAL INSPECTOR ARE REQUIRED
FOR CONCRETE CONSTRUCTION AND SPECIFIED IN THE FOLLOWING TABLE
1. Inspect reinforcement, including
prestressing tendons, and verify placement
PERIODIC
SPECIAL
INSPECTION
CONTINUOUS
SPECIAL
INSPECTION
Reference
Standard
IBC
ReferenceTYPE
2. Reinforcing bar welding:
a. Verify weldability of reinforcing bars other
than ASTM A 706;
b. Inspect single-pass fillet welds, maximum
5/16"; and
c. Inspect all other welds
3. Inspect anchors post-installed in concrete.
4. Inspect anchors post-installed in hardened
concrete members.
a. Adhesive anchors installed in horizontally
or upwardly inclined orientations to resist
sustained tension loads.
b. Mechanical anchors and adhesive
anchors not defined in 4.a.
5. Verify use of required design mix.
6. Prior to concrete placement, fabricate
specimens for strength tests, and determine
the temperature of the concrete.
7. Inspect concrete and shotcrete placement
for proper application techniques.
8. Verify maintenance of specified curing
temperature and techniques.
9. Inspect prestressed concrete for:
a. Application of prestressing forces; and
b. Grouting of bonded prestressing tendons.
10. Inspect erection of precast concrete
members.
11. Verify in-situ concrete strength, prior to
stressing of tendons in post-tensioned
concrete and prior to removal of shores and
forms from beams and structural slabs.
12. Inspect formwork for shape, location and
dimensions of the concrete member being
formed.
ACI 318
Ch. 20,25.2,25.3,
26.6.1-26.6.3
AWS D1.4
ACI 318: 26.6.4
ACI 318: 17.8.2
ACI 318: 17.8.2.4
ACI 318: 17.8.2
ACI 318: Ch 19,
26.4.3, 26.4.4
ASTM C 172
ASTM C 31
ACI 318: 26.5, 26.12
ACI 318: 26.5
ACI 318:
26.5.3-26.5.5
ACI 318: 26.10
ACI 318: 26.9
ACI 318: 26.11.2
ACI 318:
26.11.1.2(b)
1908.4
1904.1,1904.2,
1908.2, 1908.3
1908.10
1908.6,
1908.7,
1908.8
1908.9
VERIFICATION
& INSPECTION
1. Welding qualification records
and continuity records.
5. Welder identification system.
a. Joint preparations.
8. Configuration and finish of
access holes.
Quality Assurance Reference
Standard
b. Dimensions (alignment, root
opening, root face, bevel).
a. Dimensions (alignment, gaps
at root).
c. Cleanliness (condition of steel
surfaces).
AISC 360-16
TABLE N5.4-1
3. Manufacture certifications for
welding consumables available.
4. Material identification ( type /
grade).
6. Fit-up groove welds ( including
joint geometry).
d. Tacking (tack weld quality and
location).
e. Backing type and fit (if
applicable).
9. Fit-up of fillet welds.
b. Cleanliness (condition of steel
surfaces).
10. Check welding equipment.
Performed Observed
3. Environmental conditions.
a. Wind speed within limits.
b. Precipitation and temperature.
g. Proper position (F, V, H, OH ).
a. Settings on welding equipment.
AISC 360-16
TABLE N5.4-2
1. Control and handling of welding
consumables.
2. No welding over cracked
tack welds.
b. Travel speed.
c. Selected welding materials.
5. Welding techniques.
4. WPS followed:
d. Shielding gas type/ flow rate.
e. Preheat applied.
f. Interpass temperature
maintained (min./ max.).
a. Interpass and final cleaning.
b. Each pass within profile
limitations.
c. Each pass meets quality
requirements.
1. Welds cleaned.
b. Weld/ base-metal fusion.
c. Crater cross section.
e. Weld size.
AISC 360-16
TABLE N5.4-3
2. Size, length and location of
welds.
3. Welds meet visual acceptance
criteria.
f. Undercut.
g. Porosity.
9. Document acceptance or
rejection of welded joint or
member.
a. Crack prohibition.
d. Weld profiles.
4. Arc strikes.
5. K-area.
7. Backing removed and weld tabs
removed (if required).
8. Repair activities.
TASKS PRIOR TO WELDING
TASKS DURING WELDING
TASKS AFTER WELDING
c. Tacking (tack weld quality
and location).
a. Packaging.
b. Exposure control.
2. WPS available.
10. No prohibited welds have been
added without the approval of
the EOR.
6. Weld access holes in rolled
shapes and built-up heavy
shapes.
6. Placement and installation of
steel headed stud anchors.
a. Joint preparation.
b. Dimensions (alignment, root
opening, root face, bevel).
c. Cleanliness (condition of steel
surfaces).
7. Fit-up of CJP groove welds
of HSS T-, Y- and K-joints
without backing (including joint
geometry).
d. Tacking (tack weld quality and
location).
JOB NUMBER:
ENGINEER:
DRAFTER:
ORIGINAL ISSUE:
4-
U
N
I
T
C
O
N
D
O
M
I
N
I
U
M
43
G
E
N
O
A
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
21153
JL
JL
03/11/2022
1
PLAN CHECK COMMENTS
06/26/2022 JL
2
PLAN CHECK COMMENTS
5/17/2023 JL
JKLSTRUCTURAL@GMAIL.COM
(626) 524-2210
THE ENGINEER EXPRESSLY RESERVES HIS COMMON LAW
COPYRIGHT IN THESE PLANS. THESE PLANS ARE NOT TO
BE REPRODUCED, CHANGED, OR COPIED IN ANY MANNER
WHATSOEVER, NOR ASSIGNED TO ANY OTHER THIRD
PARTY WITHOUT THE EXPRESSED WRITTEN CONSENT OF
JKL ENGINEERING, INC.
SP
SP
E
C
I
A
L
I
N
S
P
E
C
T
I
O
N
S
UNIT C AND D FOUNDATION PLAN
UNIT A AND B FOUNDATION PLAN
UNIT "B" GARAGEUNIT "A" GARAGE "UNIT B"
"UNIT A"
BEDROOM 1
BATH 1
BEDROOM 1
BATH 1
UNIT "D" GARAGE
UNIT "C" GARAGE ENTRY
BATH 1
"UNIT C""UNIT D"
BEDROOM 1
BATH 1
BEDROOM 1
JOB NUMBER:
ENGINEER:
DRAFTER:
ORIGINAL ISSUE:
4-
U
N
I
T
C
O
N
D
O
M
I
N
I
U
M
43
G
E
N
O
A
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
21153
JL
JL
03/11/2022
1
PLAN CHECK COMMENTS
06/26/2022 JL
2
PLAN CHECK COMMENTS
5/17/2023 JL
JKLSTRUCTURAL@GMAIL.COM
(626) 524-2210
THE ENGINEER EXPRESSLY RESERVES HIS COMMON LAW
COPYRIGHT IN THESE PLANS. THESE PLANS ARE NOT TO
BE REPRODUCED, CHANGED, OR COPIED IN ANY MANNER
WHATSOEVER, NOR ASSIGNED TO ANY OTHER THIRD
PARTY WITHOUT THE EXPRESSED WRITTEN CONSENT OF
JKL ENGINEERING, INC.
S1
FO
U
N
D
A
T
I
O
N
P
L
A
N
4x
4
HTT
4
SD1
1
SLAB ON GRADE. SEE SCHEDULE.
EDGE OF FOOTING BELOW. SEE SCHEDULE.
SLAB EDGE OR CHANGE IN ELEVATION.
4.
DETAIL CALLOUT. SEE DETAIL NUMBER ON SHEET NUMBER AS SHOWN
INDICATES POST SIZE AND SIMPSON HOLDOWN ANCHOR OR STRAP. INSTALL
HOLDOWN ANCHOR PER MANUFACTURER'S RECOMMENDATIONS AND DETAIL
CALLOUT 1/SD4 AND 8/SD1.
SHEAR WALL CALLOUT INDICATES SHEAR WALL TYPE AND LENGTH. SEE TO
SHEAR SCHEDULE (BELOW), ANCHOR BOLT SCHEDULE (FND PLAN), AND
DETAIL CALLOUT 12/SD2 FOR MORE INFORMATION.
DETAIL NUMBER
SHEET NUMBER
2.
1.
(SEE DETAILS ON SD1)
4" MIN SLAB THICKNESS
18 X 18
30" SQ MIN. X 24" D MIN.
18 X 24
AT SLAB CENTERLINE
GRADE BM.
SLAB ON GRADE*#4 @ 16" O.C. EACH WAY
ISOLATED PAD
DESCRIPTION
INT. CONT.
#5 @ 12" O.C. EACH WAY
W x D (INCHES)REBAR REQUIREMENT
2-#5 TOP AND BOTTOM
EXT. CONT.18 X 24 2-#5 TOP AND BOTTOM
TIE BEAM 2-#5 TOP AND BOTTOM
* PER THE GEOTECHNICAL REPORT, CONCRETE SLABS IN MOISTURE SENSITIVE AREAS SHOULD BE
UNDERLAIN WITH A VAPOR BARRIER CONSISTING OF 10 MIL VAPOR BARRIER WITH ALL LAPS SEALED,
AND A MINIMUM OF 2" SAND OVER THE MEMBRANE. IF CONCRETE IS TO BE POURED DIRECTLY ON THE
VAPOR BARRIER, MINIMUM CONCRETE f'c SHALL BE 4500 psi. ALL SUBGRADE AND FOUNDATION
RECOMMENDATIONS SHALL BE CONFIRMED WITH THE FINAL GEOTECHNICAL REPORT.
16
5/8
0.2290.2290.2290.2290.229
33333
16
5/8
SHEAR
NO
2
3/16
SQUARE SIZE (INCHES)
THICKNESS (INCHES)
PLATE WASHER
2x2x
2432
5/85/85/8
2x2x2xMUD SILL
SHEAR WALL DESIGNATION
CONSTRUCTION
BOLT DIAMETER (INCHES)
SPACING (INCHES O.C.)
1/2
48 32
2x
FOOTNOTES
FOOTNOTES:
A. FOR INTERIOR NON-SHEAR WALLS, SHOT PINS MAY BE USED IN LIEU OF ANCHOR BOLTS. USE
0.145" SHOT PINS @ 24" O.C. MIN. WITH MIN. 1.25" PENETRATION INTO CONCRETE (ICC-ES REPORT
#2379).
B. THE HOLE IN 3" SQUARE PLATE WASHERS FOR ANCHOR BOLTS MAY BE DIAGONALLY SLOTTED
WITH A WIDTH OF UP TO 316" LARGER THAN THE BOLT DIAMETER AND A SLOT LENGTH NOT TO
EXCEED 134", PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER
AND THE NUT.
C. SQUARE PLATE WASHERS SHALL EXTEND TO WITHIN
12" OF THE EDGE OF THE SILL PLATE ON
SHEATHING SIDE.
D. STANDARD CUT WASHERS ARE PERMITTED PER ANSI / AF AND PA SDPWS - 2015 TABLE A2.
E. ALL FOUNDATION SILLS SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD.
FIELD-CUT ENDS, NOTCHES, AND DRILLED HOLES OF PRESERVATIVE-TREATED WOOD SHALL BE
FIELD-TREATED PER AWPA M4.
THE SPECIFIED FOOTING EMBEDMENT DEPTH, D, SHALL BE MEASURED FROM
THE LOWEST ADJACENT FINAL COMPACTED OR NATURAL GRADE WITHIN 5' OF
THE BUILDING FOOTPRINT. SLOPES OF ADJACENT AREAS SHALL BE
CONSIDERED WHEN DETERMINING THIS MINIMUM EMBEDMENT DEPTH
REQUIREMENT.
1. THE NOTES ON SHEET SD0, THE TYPICAL STRUCTURAL DETAILS ON ALL SHEETS, AND THE
FOLLOWING NOTES SHALL APPLY TO ALL FOUNDATION CONSTRUCTION.
2. ALL FOUNDATION RECOMMENDATIONS ARE BASED ON THE SOILS REPORT LISTED ON SHEET SD0. IF
THE REPORT'S RECOMMENDATIONS ARE MODIFIED IN ANY WAY, THE ENGINEER OF RECORD AND
THE ARCHITECT SHALL BE NOTIFIED.
3. THE REQUIREMENTS OF THE SOILS REPORT SHALL GOVERN IF THEY ARE MORE STRINGENT THAN
THE REQUIREMENTS OF THESE PLANS.
4. FOUNDATION PLANS AND DETAILS SHALL BE REVIEWED AND STAMPED BY GEOTECHNICAL ENGINEER
OF RECORD.
5. FOUNDATION SHALL BE EXAMINED AND CERTIFIED IN WRITING BY THE PROJECT GEOTECHNICAL
ENGINEER PRIOR TO PLACEMENT OF CONCRETE OR INSPECTION BY THE LOCAL JURISDICTION.
6. ALL FOUNDATION HARDWARE AND REINFORCEMENT SHALL BE SECURELY TIED IN PLACE PRIOR TO
FOUNDATION INSPECTION AND CONCRETE POUR.
7. GARAGE SHALL BE SLOPED TO DRAIN PER ARCHITECTURAL PLANS.
8. CRACK CONTROL JOINTS (SAWCUTS) ARE RECOMMENDED AT 15' O.C. MAX IN EACH DIRECTION FOR
CONVENTIONAL CONCRETE SLABS. ADDITIONAL JOINTS MAY BE ADDED IN ACCORDANCE WITH GOOD
CONSTRUCTION PRACTICES AND CONTRACTOR EXPERIENCE.
9. PLUMBING SHALL NOT BE INSTALLED IN SHEAR WALLS.
10. ALL PAVING, FLAT WORK, PLANTERS, AND GRADE ADJACENT TO THE BUILDING SHALL SLOPE AWAY
FROM THE BUILDING.
FOUNDATION NOTES
FOUNDATION LEGEND
FOOTING & SLAB SCHEDULE
ANCHOR BOLT SCHEDULE
TYPICAL FOUNDATION DETAILS, UNO
DESCRIPTION DETAIL
EXTERIOR FOOTING SD1
1
INTERIOR FOOTING SD1
2 HOLD DOWN ANCHOR SD1
8
ANCHOR BOLTS SD1
14
DESCRIPTION DETAIL
3.
8'-0"
4
GARAGE CURB FOOTING SD1
5
6 4 3 2 1
INTERIOR PAD FOOTING SD1
3
EXTERIOR PAD FOOTING SD1
4
REFER TO GRADING PLANS FOR LOCATIONS OF DEEPENED FOOTINGS IF
OCCURS. DEEPENED FOOTINGS SHALL BE CONSTRUCTED PER DETAIL 1/SD1,
UNO. CONTACT JKL IF DEEPER FOOTINGS ARE NEEDED.
18 X 24 2-#5 TOP AND BOTTOM
B,C,EA,D,E B,C,E B,C,E B,C,E B,C,E
UNIT C AND D 2ND FLOOR FRAMING PLAN
UNIT A AND B 2ND FLOOR FRAMING PLAN
UNIT "B" GARAGEUNIT "A" GARAGE "UNIT B"
"UNIT A"
BEDROOM 1
BATH 1
BEDROOM 1
BATH 1
UNIT "D" GARAGE
UNIT "C" GARAGE ENTRY
BATH 1
"UNIT C""UNIT D"
BEDROOM 1
BATH 1
BEDROOM 1
JOB NUMBER:
ENGINEER:
DRAFTER:
ORIGINAL ISSUE:
4-
U
N
I
T
C
O
N
D
O
M
I
N
I
U
M
43
G
E
N
O
A
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
21153
JL
JL
03/11/2022
1
PLAN CHECK COMMENTS
06/26/2022 JL
2
PLAN CHECK COMMENTS
5/17/2023 JL
JKLSTRUCTURAL@GMAIL.COM
(626) 524-2210
THE ENGINEER EXPRESSLY RESERVES HIS COMMON LAW
COPYRIGHT IN THESE PLANS. THESE PLANS ARE NOT TO
BE REPRODUCED, CHANGED, OR COPIED IN ANY MANNER
WHATSOEVER, NOR ASSIGNED TO ANY OTHER THIRD
PARTY WITHOUT THE EXPRESSED WRITTEN CONSENT OF
JKL ENGINEERING, INC.
S2
2N
D
F
L
O
O
R
F
R
A
M
I
N
G
P
L
A
N
7"32"10"13"17"26"LTP5
RIM (EXTERIOR OR INTERIOR)
BLOCKING (INTERIOR)
8"48"11"15"19"28"LTP4
2"
9"
2"
FOOTNOTES:
A. FRAMING AT ADJOINING PANEL EDGES SHALL BE 3-INCH NOMINAL OR WIDER
B. APA STRUCT 1 RATED SHEATHING
C. PERIODIC SPECIAL INSPECTION IS REQUIRED FOR NAILING, BOLTING, ANCHORING AND OTHER
FASTENING OF COMPONENTS OF THE SHEAR WALL PER 1705.12.2, EXCEPT FOR WHERE THE
FASTENER SPACING OF THE SHEATHING IS EQUAL TO OR MORE THAN 4" ON CENTER AND
OCCUPANCIES IN GROUP R-3 AND OCCUPANCIES IN GROUP U THAT ARE ACCESSORY TO A
RESIDENTIAL OCCUPANCY, INCLUDING BUT NOT LIMITED TO THOSE LISTED IN SECTION 312.1
GENERAL NOTES:
1. ALL NAILING SHALL BE STAGGERED WHERE SPACING IS 4" OR LESS ON CENTER.
2. ALL FIELD NAILING SHALL BE 12" O.C.
3. USE THE "NON-SHEAR" CONNECTOR SCHEDULE AT ALL NON-SHEAR WALLS.
4. ALL SHEATHING EDGES SHALL BE BLOCKED.
3/8"3/8"3/8"
C
10d AT 2"
15/32"
870
A,B,C
2x/2x
640490380260N/AWALL CAPACITY (PLF)
-A,CA,CFOOTNOTES
8"
32"
8"
2x/2x
N/A
N/A
SHEAR
NON-
6" 4" 3" 2"
12"15"20"30"
8d AT 2"
2"
2x/2x
8d AT 3"
3"
2x/2x
8d AT 4"
4"
2x/2x2x/2x
6"
8d AT 6"
3/8"
MUD SILL / UPPER FLOOR SOLE
(COMMON NAILS)
APA RATED SHEATHING
A35
16d
12d
CONSTRUCTION
MIN. MEMBER ABOVE & BELOW WALL
CONNECTOR SPACING (O.C.)
SHEAR SCHEDULE - 2019 CBC (CUSTOM HOME)
1/4" SDWS SCREWS W/ 1.75"20" 13" 10" 8"-6"
CONTINUOUS JOIST (INTERIOR)
RBC 20" 13 10" 8"29"6"
BOUNDARY / EDGE NAILING
FRAMING LEGEND
FRAMING NOTES
1. THE SPECIFICATIONS AND NOTES ON SHEET SD0, THE TYPICAL STRUCTURAL DETAILS ON ALL
SHEETS, AND THE FOLLOWING NOTES APPLY ALL STRUCTURAL FRAMING.
2. FLOOR FRAMING SHALL BE PER DETAIL 2/SD2 AND 3/SD2.
3. WALL FRAMING SHALL BE PER DETAIL 12/SD2.
4. WALLS SHALL BE FRAMED WITH CONTINUOUS STUDS FROM THE FLOOR TO THE BOTTOM OF ROOF
RAFTERS/ROOF TRUSSES AT ALL SHEAR OR BEARING WALLS.
5. SHEAR PANEL MAY BE INSTALLED AT EITHER FACE OF WALL AS LONG AS MINIMUM LENGTHS AND
MAXIMUM OPENINGS SIZES ARE MAINTAINED.
6. CARRY ALL BEARING MULTIPLE STUDS OR POSTS FROM UPPER LEVELS DOWN TO FIRST FLOOR OR
BEAM BELOW. INSTALL SQUASH BLOCK AT THE INTERMEDIATE FLOOR LEVEL TO AT MINIMUM MATCH
THE SIZE OF THE STUDS OR POSTS ABOVE.
7. SHEAR WALLS CAN NOT BE USED AS PLUMBING WALLS UNLESS APPROVED BY JKL ENGINEERING IN
WRITING.
8. HOLES IN I-JOISTS SHALL NOT EXCEED THOSE ALLOWED BY JOIST MANUFACTURER. NOTCHES AND
HOLES IN PLATES AND 2X JOISTS SHALL NOT EXCEED THOSE SHOWN IN DETAIL 12/SD2.
9. ALTERNATE PRODUCTS MAY BE USED IN LIEU OF SPECIFIED SIMPSON HARDWARE AS LONG AS THEIR
CAPACITIES ARE EQUAL TO OR BETTER, SUBJECT TO WRITTEN APPROVAL BY JKL ENGINEERING.
10. SHEATHING NAILING AND INSTALLATION SHALL NOT BE COVERED PRIOR TO STRUCTURAL
OBSERVATION BY JKL ENGINEERING AND INSPECTION BY THE BUILDING DEPARTMENT.
11. FOR HORIZONTAL CS STRAPS INSTALLED OVER BLOCKING (2X OR I-JOIST), 10D NAILS MAY BE
INSTALLED IN EVERY OTHER HOLE EXCEPT WHERE THERE IS INSUFFICIENT END LENGTH.
12. CONTINUOUS 1
34" LSL RIM BOARDS SHOULD BE USED AT ALL FLOOR FRAMING EDGES WHERE EVER
POSSIBLE. ALL RIM BREAKS SHOULD BE SPLICE WITH MINIMUM MSTA36 PER 2/SD4, U.N.O.
13. "DROP" BEAMS SHALL BE INSTALLED WITH THE TOP OF BEAM FLUSH WITH THE TOP OF WALL PLATES.
SUPPORT PER DETAIL 10/SD2 AND STRAP PER 9/SD4 (WHERE PARALLEL FRAMING OCCURS), U.N.O.
ON PLANS.
14. "FLUSH" / "BOTTOM FLUSH" BEAMS SHALL BE INSTALLED WITH THE BOTTOM OF BEAM DIRECTLY
OVER THE TOP OF WALL PLATES. SUPPORT PER DETAIL 10/SD2 AND STRAP PER 9/SD4 (WHERE
PARALLEL FRAMING OCCURS), U.N.O. ON PLANS.
15. "TOP FLUSH" BEAMS SHALL BE INSTALLED WITH THE TOP OF BEAM DIRECTLY BELOW THE
SHEATHING. SUPPORT PER DETAIL 10/SD2 AND STRAP WITH MSTA36 (U.N.O.) AT SIDE OF BEAM
(WHERE PARALLEL FRAMING OCCURS), U.N.O. ON PLANS.
16. "CEILING" BEAMS OR "CB" SHALL BE INSTALLED PER "FLUSH" BEAMS AS NOTED ABOVE.
17. FRAMING FOR PERIMETER FIREPLACE FLUES SHALL BE A MINIMUM OF 2X4 STUDS AT 16" O.C.
BRACED AT MID HEIGHT AND AT FLOOR AND ROOF LEVELS. MAXIMUM UNBRACED LENGTH OF STUDS
SHALL BE 14' (7' FOR CANTILEVERS).
18. ALL MULTIPLE 2X MEMBERS SHALL BE LAMINATED WITH 16D NAILS AT 12" O.C. (ONE ROW FOR UP TO
2X6 MEMBERS, 2 ROWS FOR UP TO 2X10 MEMBERS, 3 ROWS FOR UP TO 2X14 MEMBERS), UNLESS
NOTED OTHERWISE.
19. ALL FLUSH AND TOP FLUSH BEAMS SHALL BE BOUNDARY NAILED AND HAVE MINIMUM 2-2X
SUPPORTS U.N.O.
6 4 3 2 1
INDICATES FRAMING MEMBER AS DEFINED BELOW.
INDICATES CANTILEVERED MEMBER AS DEFINED ABOVE.
INDICATES HANGING CONDITION AT JOISTS/RAFTERS/TRUSSES. SEE SD0 FOR
HANGER U.N.O.
INDICATES BEARING CONDITION AT JOISTS/RAFTERS/TRUSSES
5.
RR - INDICATES 2 X 8 ROOF RAFTERS AT 24" O.C. (MAX SPAN=12'-0"), U.N.O.
FJ - INDICATES 1178" TJI 210 SERIES FLOOR JOISTS AT 16" O.C. MAX, U.N.O.
4.
CANT. **2.
1.**
3.
**INDICATES CEILING JOIST AS DEFINED BELOW
CJ - INDICATES CEILING JOISTS PER TABLE BELOW OR SEE 4/SD3 FOR ADD'L SPANS
1.25"LSL1.25"LSLTJI 210
1.25" LSL1.25"LSL 1.25"LSL1.25"LSL1.25"LSL1.25"LSL
1.25" LSLTJI 210 TJI 210
TJI 210 TJI 210 1.25"LSL 1.25"LSLTJI 210 1.25" LSL
MIN PENETRATION INTO RIM
2X6 AT 24" O.C. MAX SPAN = 11'-6"
2X10 AT 24" O.C. MAX SPAN = 17'-6"
2X8 AT 24" O.C. MAX SPAN = 14'-6"
2X12 AT 24" O.C. MAX SPAN = 21'-0"
4x
4
HT
T
4
SD1
1
DETAIL CALLOUT. SEE DETAIL NUMBER ON SHEET NUMBER AS SHOWN
INDICATES POST SIZE AND SIMPSON HOLDOWN ANCHOR OR STRAP. INSTALL
HOLDOWN ANCHOR PER MANUFACTURER'S RECOMMENDATIONS AND DETAIL
CALLOUT 1/SD4 AND 8/SD1.
SHEAR WALL CALLOUT INDICATES SHEAR WALL TYPE AND LENGTH. SEE TO
SHEAR SCHEDULE (BELOW), ANCHOR BOLT SCHEDULE (FND PLAN), AND
DETAIL CALLOUT 12/SD2 FOR MORE INFORMATION.
DETAIL NUMBER
SHEET NUMBER
7.
6.
8'-0"
4
PSL - INDICATES 2.0E PARALLAM BEAM TO MATCH DEPTH OF FLOOR FRAMING W/ BN
LSL - INDICATES 134 1.55E TIMBERSTRAND BEAM TO MATCH DEPTH OF FLOOR FRAMING W/ BN U.N.O.
ML - INDICATES 1.9E MICROLLAM BEAM TO MATCH DEPTH OF FLOOR FRAMING W/ BN
**INDICATES BEAM/JOIST/RIM AS DEFINED BELOW.
8.
9.
POST ABOVE10.
KEY NOTES
INSTALL VERTICAL MSTA24 U.N.O. FROM BEAM / HEADER / RIM ABOVE TO POST / TRIMMER BELOW.
BLOCK ROOF DIAPHRAGM W/ 8d AT 4" O.C. OR FLOOR DIAPHRAGM W/ 10d AT 4" O.C. PER 9/SD2.
ALIGN FRAMING MEMBER WITH POST / TRIMMER / BEAM ABOVE OR BELOW.
INSTALL PLUMBING / A/C / ELECTRICAL LINES THROUGH SOFFIT / CHASE / NON-STRUCTURAL WALL AND
DO NOT PENETRATE TOP PLATES.
ALIGN WITH POST / KING POST / TRIMMER ABOVE / BELOW. MATCH W/ ABOVE U.N.O.
PROVIDE FULL DEPTH BLOCKING TO MATCH WIDTH OF POST ABOVE.
STITCH NAIL 2X MEMBER WITH 16d PER SHEAR SCHEDULE TO ADJACENT POST/2X STUD.
INSTALL 13'-0" LONG CS14 WRAPPED AROUND CHIMNEY OVER 2X BLOCKING AND 3'-0" ONTO SIDE OF
ALIGNED BEAM EACH SIDE.
INSTALL VERTICAL TWIST STRAP PER PLAN (HTS24 MIN) FROM BEAM / HEADER TO POST / TRIMMER /
KING POST. INSTALL ADDITIONAL VERTICAL ST6224 TO MATCH NUMBER OF TWIST STRAPS TO HEADER
/ BEAM / POST BELOW WHERE OCCURS.
INSTALL HOLD DOWN ON THIS SIDE OF POST.
TYPICAL FRAMING DETAILS, UNO
DESCRIPTION DETAIL
FLOOR FRAMING AT SHEAR
SD2
2
FRAMING AT NON-BRG WALL SD2
3 STRUCTURAL WALL FRAMING SD2
12
HOLD DOWN CONNECTIONS SD4
1
DESCRIPTION DETAIL
POST AND BEAM CONNECTION SD2
10
DRAG STRAPS SD4
9
TYPICAL STAIR FRAMING SD2
4
TYPICAL TOP PLATE SPLICE SD2
5
AND BEARING WALLS
UNIT C AND D 3RD FLOOR FRAMING PLAN
UNIT A AND B 3RD FLOOR FRAMING PLAN
DININGLIVING
KITCHEN
LIVING
DINING
"UNIT B"
"UNIT A"
BEDROOM 3
BATH 2
KITCHEN
BALCONY
BEDROOM 2 BEDROOM 2
BATH 2
"UNIT C"
"UNIT D"
LIVING
DINING
DINING
LIVING
KITCHEN
BALCONY
BEDROOM 2 BEDROOM 2
BATH 2
BATH 2
BALCONY
JOB NUMBER:
ENGINEER:
DRAFTER:
ORIGINAL ISSUE:
4-
U
N
I
T
C
O
N
D
O
M
I
N
I
U
M
43
G
E
N
O
A
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
21153
JL
JL
03/11/2022
1
PLAN CHECK COMMENTS
06/26/2022 JL
2
PLAN CHECK COMMENTS
5/17/2023 JL
JKLSTRUCTURAL@GMAIL.COM
(626) 524-2210
THE ENGINEER EXPRESSLY RESERVES HIS COMMON LAW
COPYRIGHT IN THESE PLANS. THESE PLANS ARE NOT TO
BE REPRODUCED, CHANGED, OR COPIED IN ANY MANNER
WHATSOEVER, NOR ASSIGNED TO ANY OTHER THIRD
PARTY WITHOUT THE EXPRESSED WRITTEN CONSENT OF
JKL ENGINEERING, INC.
S3
3R
D
F
L
O
O
R
F
R
A
M
I
N
G
P
L
A
N
7"32"10"13"17"26"LTP5
RIM (EXTERIOR OR INTERIOR)
BLOCKING (INTERIOR)
8"48"11"15"19"28"LTP4
2"
9"
2"
FOOTNOTES:
A. FRAMING AT ADJOINING PANEL EDGES SHALL BE 3-INCH NOMINAL OR WIDER
B. APA STRUCT 1 RATED SHEATHING
C. PERIODIC SPECIAL INSPECTION IS REQUIRED FOR NAILING, BOLTING, ANCHORING AND OTHER
FASTENING OF COMPONENTS OF THE SHEAR WALL PER 1705.12.2, EXCEPT FOR WHERE THE
FASTENER SPACING OF THE SHEATHING IS EQUAL TO OR MORE THAN 4" ON CENTER AND
OCCUPANCIES IN GROUP R-3 AND OCCUPANCIES IN GROUP U THAT ARE ACCESSORY TO A
RESIDENTIAL OCCUPANCY, INCLUDING BUT NOT LIMITED TO THOSE LISTED IN SECTION 312.1
GENERAL NOTES:
1. ALL NAILING SHALL BE STAGGERED WHERE SPACING IS 4" OR LESS ON CENTER.
2. ALL FIELD NAILING SHALL BE 12" O.C.
3. USE THE "NON-SHEAR" CONNECTOR SCHEDULE AT ALL NON-SHEAR WALLS.
4. ALL SHEATHING EDGES SHALL BE BLOCKED.
3/8"3/8"3/8"
C
10d AT 2"
15/32"
870
A,B,C
2x/2x
640490380260N/AWALL CAPACITY (PLF)
-A,CA,CFOOTNOTES
8"
32"
8"
2x/2x
N/A
N/A
SHEAR
NON-
6" 4" 3" 2"
12"15"20"30"
8d AT 2"
2"
2x/2x
8d AT 3"
3"
2x/2x
8d AT 4"
4"
2x/2x2x/2x
6"
8d AT 6"
3/8"
MUD SILL / UPPER FLOOR SOLE
(COMMON NAILS)
APA RATED SHEATHING
A35
16d
12d
CONSTRUCTION
MIN. MEMBER ABOVE & BELOW WALL
CONNECTOR SPACING (O.C.)
SHEAR SCHEDULE - 2019 CBC (CUSTOM HOME)
1/4" SDWS SCREWS W/ 1.75"20" 13" 10" 8"-6"
CONTINUOUS JOIST (INTERIOR)
RBC 20" 13 10" 8"29"6"
BOUNDARY / EDGE NAILING
FRAMING LEGEND
FRAMING NOTES
1. THE SPECIFICATIONS AND NOTES ON SHEET SD0, THE TYPICAL STRUCTURAL DETAILS ON ALL
SHEETS, AND THE FOLLOWING NOTES APPLY ALL STRUCTURAL FRAMING.
2. FLOOR FRAMING SHALL BE PER DETAIL 2/SD2 AND 3/SD2.
3. WALL FRAMING SHALL BE PER DETAIL 12/SD2.
4. WALLS SHALL BE FRAMED WITH CONTINUOUS STUDS FROM THE FLOOR TO THE BOTTOM OF ROOF
RAFTERS/ROOF TRUSSES AT ALL SHEAR OR BEARING WALLS.
5. SHEAR PANEL MAY BE INSTALLED AT EITHER FACE OF WALL AS LONG AS MINIMUM LENGTHS AND
MAXIMUM OPENINGS SIZES ARE MAINTAINED.
6. CARRY ALL BEARING MULTIPLE STUDS OR POSTS FROM UPPER LEVELS DOWN TO FIRST FLOOR OR
BEAM BELOW. INSTALL SQUASH BLOCK AT THE INTERMEDIATE FLOOR LEVEL TO AT MINIMUM MATCH
THE SIZE OF THE STUDS OR POSTS ABOVE.
7. SHEAR WALLS CAN NOT BE USED AS PLUMBING WALLS UNLESS APPROVED BY JKL ENGINEERING IN
WRITING.
8. HOLES IN I-JOISTS SHALL NOT EXCEED THOSE ALLOWED BY JOIST MANUFACTURER. NOTCHES AND
HOLES IN PLATES AND 2X JOISTS SHALL NOT EXCEED THOSE SHOWN IN DETAIL 12/SD2.
9. ALTERNATE PRODUCTS MAY BE USED IN LIEU OF SPECIFIED SIMPSON HARDWARE AS LONG AS THEIR
CAPACITIES ARE EQUAL TO OR BETTER, SUBJECT TO WRITTEN APPROVAL BY JKL ENGINEERING.
10. SHEATHING NAILING AND INSTALLATION SHALL NOT BE COVERED PRIOR TO STRUCTURAL
OBSERVATION BY JKL ENGINEERING AND INSPECTION BY THE BUILDING DEPARTMENT.
11. FOR HORIZONTAL CS STRAPS INSTALLED OVER BLOCKING (2X OR I-JOIST), 10D NAILS MAY BE
INSTALLED IN EVERY OTHER HOLE EXCEPT WHERE THERE IS INSUFFICIENT END LENGTH.
12. CONTINUOUS 1
34" LSL RIM BOARDS SHOULD BE USED AT ALL FLOOR FRAMING EDGES WHERE EVER
POSSIBLE. ALL RIM BREAKS SHOULD BE SPLICE WITH MINIMUM MSTA36 PER 2/SD4, U.N.O.
13. "DROP" BEAMS SHALL BE INSTALLED WITH THE TOP OF BEAM FLUSH WITH THE TOP OF WALL PLATES.
SUPPORT PER DETAIL 10/SD2 AND STRAP PER 9/SD4 (WHERE PARALLEL FRAMING OCCURS), U.N.O.
ON PLANS.
14. "FLUSH" / "BOTTOM FLUSH" BEAMS SHALL BE INSTALLED WITH THE BOTTOM OF BEAM DIRECTLY
OVER THE TOP OF WALL PLATES. SUPPORT PER DETAIL 10/SD2 AND STRAP PER 9/SD4 (WHERE
PARALLEL FRAMING OCCURS), U.N.O. ON PLANS.
15. "TOP FLUSH" BEAMS SHALL BE INSTALLED WITH THE TOP OF BEAM DIRECTLY BELOW THE
SHEATHING. SUPPORT PER DETAIL 10/SD2 AND STRAP WITH MSTA36 (U.N.O.) AT SIDE OF BEAM
(WHERE PARALLEL FRAMING OCCURS), U.N.O. ON PLANS.
16. "CEILING" BEAMS OR "CB" SHALL BE INSTALLED PER "FLUSH" BEAMS AS NOTED ABOVE.
17. FRAMING FOR PERIMETER FIREPLACE FLUES SHALL BE A MINIMUM OF 2X4 STUDS AT 16" O.C.
BRACED AT MID HEIGHT AND AT FLOOR AND ROOF LEVELS. MAXIMUM UNBRACED LENGTH OF STUDS
SHALL BE 14' (7' FOR CANTILEVERS).
18. ALL MULTIPLE 2X MEMBERS SHALL BE LAMINATED WITH 16D NAILS AT 12" O.C. (ONE ROW FOR UP TO
2X6 MEMBERS, 2 ROWS FOR UP TO 2X10 MEMBERS, 3 ROWS FOR UP TO 2X14 MEMBERS), UNLESS
NOTED OTHERWISE.
19. ALL FLUSH AND TOP FLUSH BEAMS SHALL BE BOUNDARY NAILED AND HAVE MINIMUM 2-2X
SUPPORTS U.N.O.
6 4 3 2 1
INDICATES FRAMING MEMBER AS DEFINED BELOW.
INDICATES CANTILEVERED MEMBER AS DEFINED ABOVE.
INDICATES HANGING CONDITION AT JOISTS/RAFTERS/TRUSSES. SEE SD0 FOR
HANGER U.N.O.
INDICATES BEARING CONDITION AT JOISTS/RAFTERS/TRUSSES
5.
RR - INDICATES 2 X 8 ROOF RAFTERS AT 24" O.C. (MAX SPAN=12'-0"), U.N.O.
FJ - INDICATES 1178" TJI 210 SERIES FLOOR JOISTS AT 16" O.C. MAX, U.N.O.
4.
CANT. **2.
1.**
3.
**INDICATES CEILING JOIST AS DEFINED BELOW
CJ - INDICATES CEILING JOISTS PER TABLE BELOW OR SEE 4/SD3 FOR ADD'L SPANS
1.25"LSL1.25"LSLTJI 210
1.25" LSL1.25"LSL 1.25"LSL1.25"LSL1.25"LSL1.25"LSL
1.25" LSLTJI 210 TJI 210
TJI 210 TJI 210 1.25"LSL 1.25"LSLTJI 210 1.25" LSL
MIN PENETRATION INTO RIM
2X6 AT 24" O.C. MAX SPAN = 11'-6"
2X10 AT 24" O.C. MAX SPAN = 17'-6"
2X8 AT 24" O.C. MAX SPAN = 14'-6"
2X12 AT 24" O.C. MAX SPAN = 21'-0"
4x
4
HT
T
4
SD1
1
DETAIL CALLOUT. SEE DETAIL NUMBER ON SHEET NUMBER AS SHOWN
INDICATES POST SIZE AND SIMPSON HOLDOWN ANCHOR OR STRAP. INSTALL
HOLDOWN ANCHOR PER MANUFACTURER'S RECOMMENDATIONS AND DETAIL
CALLOUT 1/SD4 AND 8/SD1.
SHEAR WALL CALLOUT INDICATES SHEAR WALL TYPE AND LENGTH. SEE TO
SHEAR SCHEDULE (BELOW), ANCHOR BOLT SCHEDULE (FND PLAN), AND
DETAIL CALLOUT 12/SD2 FOR MORE INFORMATION.
DETAIL NUMBER
SHEET NUMBER
7.
6.
8'-0"
4
PSL - INDICATES 2.0E PARALLAM BEAM TO MATCH DEPTH OF FLOOR FRAMING W/ BN
LSL - INDICATES 134 1.55E TIMBERSTRAND BEAM TO MATCH DEPTH OF FLOOR FRAMING W/ BN U.N.O.
ML - INDICATES 1.9E MICROLLAM BEAM TO MATCH DEPTH OF FLOOR FRAMING W/ BN
**INDICATES BEAM/JOIST/RIM AS DEFINED BELOW.
8.
9.
POST ABOVE10.
KEY NOTES
INSTALL VERTICAL MSTA24 U.N.O. FROM BEAM / HEADER / RIM ABOVE TO POST / TRIMMER BELOW.
BLOCK ROOF DIAPHRAGM W/ 8d AT 4" O.C. OR FLOOR DIAPHRAGM W/ 10d AT 4" O.C. PER 9/SD2.
ALIGN FRAMING MEMBER WITH POST / TRIMMER / BEAM ABOVE OR BELOW.
INSTALL PLUMBING / A/C / ELECTRICAL LINES THROUGH SOFFIT / CHASE / NON-STRUCTURAL WALL AND
DO NOT PENETRATE TOP PLATES.
ALIGN WITH POST / KING POST / TRIMMER ABOVE / BELOW. MATCH W/ ABOVE U.N.O.
PROVIDE FULL DEPTH BLOCKING TO MATCH WIDTH OF POST ABOVE.
STITCH NAIL 2X MEMBER WITH 16d PER SHEAR SCHEDULE TO ADJACENT POST/2X STUD.
INSTALL 13'-0" LONG CS14 WRAPPED AROUND CHIMNEY OVER 2X BLOCKING AND 3'-0" ONTO SIDE OF
ALIGNED BEAM EACH SIDE.
INSTALL VERTICAL TWIST STRAP PER PLAN (HTS24 MIN) FROM BEAM / HEADER TO POST / TRIMMER /
KING POST. INSTALL ADDITIONAL VERTICAL ST6224 TO MATCH NUMBER OF TWIST STRAPS TO HEADER
/ BEAM / POST BELOW WHERE OCCURS.
INSTALL HOLD DOWN ON THIS SIDE OF POST.
TYPICAL FRAMING DETAILS, UNO
DESCRIPTION DETAIL
FLOOR FRAMING AT SHEAR
SD2
2
FRAMING AT NON-BRG WALL SD2
3 STRUCTURAL WALL FRAMING SD2
12
HOLD DOWN CONNECTIONS SD4
1
DESCRIPTION DETAIL
POST AND BEAM CONNECTION SD2
10
DRAG STRAPS SD4
9
TYPICAL STAIR FRAMING SD2
4
TYPICAL TOP PLATE SPLICE SD2
5
AND BEARING WALLS
UNIT C AND D ROOF FRAMING PLAN
UNIT A AND B ROOF FRAMING PLAN
"UNIT B""UNIT A"
BEDROOMMASTER
M. BATH
BEDROOMMASTER
W.I.CL.
M. BATH
W.I.CL.
BATH 2
BEDROOM 2BALCONY
"UNIT C"
"UNIT D"
BEDROOM 3
M. BATH
W.I.CL.
M. BATH
BEDROOMMASTER
BATH 2
BEDROOM 2
BEDROOM 2
W.I.CL.
BATH 2
BEDROOMMASTER
2
2
2
2
2
3
4
5
66
7
8
9
10
11
12
66
2
1
3
9
3
3
14
15
16
17
17
18
19
JOB NUMBER:
ENGINEER:
DRAFTER:
ORIGINAL ISSUE:
4-
U
N
I
T
C
O
N
D
O
M
I
N
I
U
M
43
G
E
N
O
A
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
21153
JL
JL
03/11/2022
1
PLAN CHECK COMMENTS
06/26/2022 JL
2
PLAN CHECK COMMENTS
5/17/2023 JL
JKLSTRUCTURAL@GMAIL.COM
(626) 524-2210
THE ENGINEER EXPRESSLY RESERVES HIS COMMON LAW
COPYRIGHT IN THESE PLANS. THESE PLANS ARE NOT TO
BE REPRODUCED, CHANGED, OR COPIED IN ANY MANNER
WHATSOEVER, NOR ASSIGNED TO ANY OTHER THIRD
PARTY WITHOUT THE EXPRESSED WRITTEN CONSENT OF
JKL ENGINEERING, INC.
S4
RO
O
F
F
R
A
M
I
N
G
P
L
A
N
7"32"10"13"17"26"LTP5
RIM (EXTERIOR OR INTERIOR)
BLOCKING (INTERIOR)
8"48"11"15"19"28"LTP4
2"
9"
2"
FOOTNOTES:
A. FRAMING AT ADJOINING PANEL EDGES SHALL BE 3-INCH NOMINAL OR WIDER
B. APA STRUCT 1 RATED SHEATHING
C. PERIODIC SPECIAL INSPECTION IS REQUIRED FOR NAILING, BOLTING, ANCHORING AND OTHER
FASTENING OF COMPONENTS OF THE SHEAR WALL PER 1705.12.2, EXCEPT FOR WHERE THE
FASTENER SPACING OF THE SHEATHING IS EQUAL TO OR MORE THAN 4" ON CENTER AND
OCCUPANCIES IN GROUP R-3 AND OCCUPANCIES IN GROUP U THAT ARE ACCESSORY TO A
RESIDENTIAL OCCUPANCY, INCLUDING BUT NOT LIMITED TO THOSE LISTED IN SECTION 312.1
GENERAL NOTES:
1. ALL NAILING SHALL BE STAGGERED WHERE SPACING IS 4" OR LESS ON CENTER.
2. ALL FIELD NAILING SHALL BE 12" O.C.
3. USE THE "NON-SHEAR" CONNECTOR SCHEDULE AT ALL NON-SHEAR WALLS.
4. ALL SHEATHING EDGES SHALL BE BLOCKED.
3/8"3/8"3/8"
C
10d AT 2"
15/32"
870
A,B,C
2x/2x
640490380260N/AWALL CAPACITY (PLF)
-A,CA,CFOOTNOTES
8"
32"
8"
2x/2x
N/A
N/A
SHEAR
NON-
6" 4" 3" 2"
12"15"20"30"
8d AT 2"
2"
2x/2x
8d AT 3"
3"
2x/2x
8d AT 4"
4"
2x/2x2x/2x
6"
8d AT 6"
3/8"
MUD SILL / UPPER FLOOR SOLE
(COMMON NAILS)
APA RATED SHEATHING
A35
16d
12d
CONSTRUCTION
MIN. MEMBER ABOVE & BELOW WALL
CONNECTOR SPACING (O.C.)
SHEAR SCHEDULE - 2019 CBC (CUSTOM HOME)
1/4" SDWS SCREWS W/ 1.75"20" 13" 10" 8"-6"
CONTINUOUS JOIST (INTERIOR)
RBC 20" 13 10" 8"29"6"
BOUNDARY / EDGE NAILING
FRAMING LEGEND
FRAMING NOTES
1. THE SPECIFICATIONS AND NOTES ON SHEET SD0, THE TYPICAL STRUCTURAL DETAILS ON ALL
SHEETS, AND THE FOLLOWING NOTES APPLY ALL STRUCTURAL FRAMING.
2. FLOOR FRAMING SHALL BE PER DETAIL 2/SD2 AND 3/SD2.
3. WALL FRAMING SHALL BE PER DETAIL 12/SD2.
4. WALLS SHALL BE FRAMED WITH CONTINUOUS STUDS FROM THE FLOOR TO THE BOTTOM OF ROOF
RAFTERS/ROOF TRUSSES AT ALL SHEAR OR BEARING WALLS.
5. SHEAR PANEL MAY BE INSTALLED AT EITHER FACE OF WALL AS LONG AS MINIMUM LENGTHS AND
MAXIMUM OPENINGS SIZES ARE MAINTAINED.
6. CARRY ALL BEARING MULTIPLE STUDS OR POSTS FROM UPPER LEVELS DOWN TO FIRST FLOOR OR
BEAM BELOW. INSTALL SQUASH BLOCK AT THE INTERMEDIATE FLOOR LEVEL TO AT MINIMUM MATCH
THE SIZE OF THE STUDS OR POSTS ABOVE.
7. SHEAR WALLS CAN NOT BE USED AS PLUMBING WALLS UNLESS APPROVED BY JKL ENGINEERING IN
WRITING.
8. HOLES IN I-JOISTS SHALL NOT EXCEED THOSE ALLOWED BY JOIST MANUFACTURER. NOTCHES AND
HOLES IN PLATES AND 2X JOISTS SHALL NOT EXCEED THOSE SHOWN IN DETAIL 12/SD2.
9. ALTERNATE PRODUCTS MAY BE USED IN LIEU OF SPECIFIED SIMPSON HARDWARE AS LONG AS THEIR
CAPACITIES ARE EQUAL TO OR BETTER, SUBJECT TO WRITTEN APPROVAL BY JKL ENGINEERING.
10. SHEATHING NAILING AND INSTALLATION SHALL NOT BE COVERED PRIOR TO STRUCTURAL
OBSERVATION BY JKL ENGINEERING AND INSPECTION BY THE BUILDING DEPARTMENT.
11. FOR HORIZONTAL CS STRAPS INSTALLED OVER BLOCKING (2X OR I-JOIST), 10D NAILS MAY BE
INSTALLED IN EVERY OTHER HOLE EXCEPT WHERE THERE IS INSUFFICIENT END LENGTH.
12. CONTINUOUS 1
34" LSL RIM BOARDS SHOULD BE USED AT ALL FLOOR FRAMING EDGES WHERE EVER
POSSIBLE. ALL RIM BREAKS SHOULD BE SPLICE WITH MINIMUM MSTA36 PER 2/SD4, U.N.O.
13. "DROP" BEAMS SHALL BE INSTALLED WITH THE TOP OF BEAM FLUSH WITH THE TOP OF WALL PLATES.
SUPPORT PER DETAIL 10/SD2 AND STRAP PER 9/SD4 (WHERE PARALLEL FRAMING OCCURS), U.N.O.
ON PLANS.
14. "FLUSH" / "BOTTOM FLUSH" BEAMS SHALL BE INSTALLED WITH THE BOTTOM OF BEAM DIRECTLY
OVER THE TOP OF WALL PLATES. SUPPORT PER DETAIL 10/SD2 AND STRAP PER 9/SD4 (WHERE
PARALLEL FRAMING OCCURS), U.N.O. ON PLANS.
15. "TOP FLUSH" BEAMS SHALL BE INSTALLED WITH THE TOP OF BEAM DIRECTLY BELOW THE
SHEATHING. SUPPORT PER DETAIL 10/SD2 AND STRAP WITH MSTA36 (U.N.O.) AT SIDE OF BEAM
(WHERE PARALLEL FRAMING OCCURS), U.N.O. ON PLANS.
16. "CEILING" BEAMS OR "CB" SHALL BE INSTALLED PER "FLUSH" BEAMS AS NOTED ABOVE.
17. FRAMING FOR PERIMETER FIREPLACE FLUES SHALL BE A MINIMUM OF 2X4 STUDS AT 16" O.C.
BRACED AT MID HEIGHT AND AT FLOOR AND ROOF LEVELS. MAXIMUM UNBRACED LENGTH OF STUDS
SHALL BE 14' (7' FOR CANTILEVERS).
18. ALL MULTIPLE 2X MEMBERS SHALL BE LAMINATED WITH 16D NAILS AT 12" O.C. (ONE ROW FOR UP TO
2X6 MEMBERS, 2 ROWS FOR UP TO 2X10 MEMBERS, 3 ROWS FOR UP TO 2X14 MEMBERS), UNLESS
NOTED OTHERWISE.
19. ALL FLUSH AND TOP FLUSH BEAMS SHALL BE BOUNDARY NAILED AND HAVE MINIMUM 2-2X
SUPPORTS U.N.O.
6 4 3 2 1
INDICATES FRAMING MEMBER AS DEFINED BELOW.
INDICATES CANTILEVERED MEMBER AS DEFINED ABOVE.
INDICATES HANGING CONDITION AT JOISTS/RAFTERS/TRUSSES. SEE SD0 FOR
HANGER U.N.O.
INDICATES BEARING CONDITION AT JOISTS/RAFTERS/TRUSSES
5.
RR - INDICATES 2 X 8 ROOF RAFTERS AT 24" O.C. (MAX SPAN=12'-0"), U.N.O.
FJ - INDICATES 1178" TJI 210 SERIES FLOOR JOISTS AT 16" O.C. MAX, U.N.O.
4.
CANT. **2.
1.**
3.
**INDICATES CEILING JOIST AS DEFINED BELOW
CJ - INDICATES CEILING JOISTS PER TABLE BELOW OR SEE 4/SD3 FOR ADD'L SPANS
1.25"LSL1.25"LSLTJI 210
1.25" LSL1.25"LSL 1.25"LSL1.25"LSL1.25"LSL1.25"LSL
1.25" LSLTJI 210 TJI 210
TJI 210 TJI 210 1.25"LSL 1.25"LSLTJI 210 1.25" LSL
MIN PENETRATION INTO RIM
2X6 AT 24" O.C. MAX SPAN = 11'-6"
2X10 AT 24" O.C. MAX SPAN = 17'-6"
2X8 AT 24" O.C. MAX SPAN = 14'-6"
2X12 AT 24" O.C. MAX SPAN = 21'-0"
4x
4
HT
T
4
SD1
1
DETAIL CALLOUT. SEE DETAIL NUMBER ON SHEET NUMBER AS SHOWN
INDICATES POST SIZE AND SIMPSON HOLDOWN ANCHOR OR STRAP. INSTALL
HOLDOWN ANCHOR PER MANUFACTURER'S RECOMMENDATIONS AND DETAIL
CALLOUT 1/SD4 AND 8/SD1.
SHEAR WALL CALLOUT INDICATES SHEAR WALL TYPE AND LENGTH. SEE TO
SHEAR SCHEDULE (BELOW), ANCHOR BOLT SCHEDULE (FND PLAN), AND
DETAIL CALLOUT 12/SD2 FOR MORE INFORMATION.
DETAIL NUMBER
SHEET NUMBER
7.
6.
8'-0"
4
PSL - INDICATES 2.0E PARALLAM BEAM TO MATCH DEPTH OF FLOOR FRAMING W/ BN
LSL - INDICATES 134 1.55E TIMBERSTRAND BEAM TO MATCH DEPTH OF FLOOR FRAMING W/ BN U.N.O.
ML - INDICATES 1.9E MICROLLAM BEAM TO MATCH DEPTH OF FLOOR FRAMING W/ BN
**INDICATES BEAM/JOIST/RIM AS DEFINED BELOW.
8.
9.
POST ABOVE10.
TYPICAL CONVENTIONAL ROOF DETAILS, U.N.O
DESCRIPTION DETAIL
RR AT EXTERIOR WALL SD3
1
RR AT RIDGE/HIP BM SD3
2
RR AT INTERIOR
SD3
4
6
DESCRIPTION DETAIL
SHR/BRG WALL
NON-BRG INT. WALL
KING POST SUPPORT
AT RIDGE/HIP BEAM
SD3
SD3
SD3
7
8
HIP AND RIDGE BEAM
CONNECTION TYPICAL HOLD DOWNS SD4
1
EXTERIOR GABLE WALL SD3
9
KEY NOTES
INSTALL VERTICAL MSTA24 U.N.O. FROM BEAM / HEADER / RIM ABOVE TO POST / TRIMMER BELOW.
BLOCK ROOF DIAPHRAGM W/ 8d AT 4" O.C. OR FLOOR DIAPHRAGM W/ 10d AT 4" O.C. PER 9/SD2.
ALIGN FRAMING MEMBER WITH POST / TRIMMER / BEAM ABOVE OR BELOW.
INSTALL PLUMBING / A/C / ELECTRICAL LINES THROUGH SOFFIT / CHASE / NON-STRUCTURAL WALL AND
DO NOT PENETRATE TOP PLATES.
ALIGN WITH POST / KING POST / TRIMMER ABOVE / BELOW. MATCH W/ ABOVE U.N.O.
PROVIDE FULL DEPTH BLOCKING TO MATCH WIDTH OF POST ABOVE.
STITCH NAIL 2X MEMBER WITH 16d PER SHEAR SCHEDULE TO ADJACENT POST/2X STUD.
INSTALL 13'-0" LONG CS14 WRAPPED AROUND CHIMNEY OVER 2X BLOCKING AND 3'-0" ONTO SIDE OF
ALIGNED BEAM EACH SIDE.
INSTALL VERTICAL TWIST STRAP PER PLAN (HTS24 MIN) FROM BEAM / HEADER TO POST / TRIMMER /
KING POST. INSTALL ADDITIONAL VERTICAL ST6224 TO MATCH NUMBER OF TWIST STRAPS TO HEADER
/ BEAM / POST BELOW WHERE OCCURS.
INSTALL HOLD DOWN ON THIS SIDE OF POST.
4
1
2
513
15
17
16
14
8
3
12
<
>
18
19
JOB NUMBER:
ENGINEER:
DRAFTER:
ORIGINAL ISSUE:
4-
U
N
I
T
C
O
N
D
O
M
I
N
I
U
M
43
G
E
N
O
A
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
21153
JL
JL
03/11/2022
1
PLAN CHECK COMMENTS
06/26/2022 JL
2
PLAN CHECK COMMENTS
5/17/2023 JL
JKLSTRUCTURAL@GMAIL.COM
(626) 524-2210
THE ENGINEER EXPRESSLY RESERVES HIS COMMON LAW
COPYRIGHT IN THESE PLANS. THESE PLANS ARE NOT TO
BE REPRODUCED, CHANGED, OR COPIED IN ANY MANNER
WHATSOEVER, NOR ASSIGNED TO ANY OTHER THIRD
PARTY WITHOUT THE EXPRESSED WRITTEN CONSENT OF
JKL ENGINEERING, INC.
SD1
ST
R
U
C
T
U
R
A
L
D
E
T
A
I
L
S
2
3
412
59
1018
17
6
7
JOB NUMBER:
ENGINEER:
DRAFTER:
ORIGINAL ISSUE:
4-
U
N
I
T
C
O
N
D
O
M
I
N
I
U
M
43
G
E
N
O
A
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
21153
JL
JL
03/11/2022
1
PLAN CHECK COMMENTS
06/26/2022 JL
2
PLAN CHECK COMMENTS
5/17/2023 JL
JKLSTRUCTURAL@GMAIL.COM
(626) 524-2210
THE ENGINEER EXPRESSLY RESERVES HIS COMMON LAW
COPYRIGHT IN THESE PLANS. THESE PLANS ARE NOT TO
BE REPRODUCED, CHANGED, OR COPIED IN ANY MANNER
WHATSOEVER, NOR ASSIGNED TO ANY OTHER THIRD
PARTY WITHOUT THE EXPRESSED WRITTEN CONSENT OF
JKL ENGINEERING, INC.
SD2
ST
R
U
C
T
U
R
A
L
D
E
T
A
I
L
S
1
2
7
4
14
8
1018 6
91713
12
1115
16
JOB NUMBER:
ENGINEER:
DRAFTER:
ORIGINAL ISSUE:
4-
U
N
I
T
C
O
N
D
O
M
I
N
I
U
M
43
G
E
N
O
A
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
21153
JL
JL
03/11/2022
1
PLAN CHECK COMMENTS
06/26/2022 JL
2
PLAN CHECK COMMENTS
5/17/2023 JL
JKLSTRUCTURAL@GMAIL.COM
(626)524-2210
THE ENGINEER EXPRESSLY RESERVES HIS COMMON LAW
COPYRIGHT IN THESE PLANS. THESE PLANS ARE NOT TO
BE REPRODUCED, CHANGED, OR COPIED IN ANY MANNER
WHATSOEVER, NOR ASSIGNED TO ANY OTHER THIRD
PARTY WITHOUT THE EXPRESSED WRITTEN CONSENT OF
JKL ENGINEERING, INC.
SD3
ST
R
U
C
T
U
R
A
L
D
E
T
A
I
L
S
2
19
3
6
4
7
812
10
15
14
20 16
18
JOB NUMBER:
ENGINEER:
DRAFTER:
ORIGINAL ISSUE:
4-
U
N
I
T
C
O
N
D
O
M
I
N
I
U
M
43
G
E
N
O
A
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
21153
JL
JL
03/11/2022
1
PLAN CHECK COMMENTS
06/26/2022 JL
2
PLAN CHECK COMMENTS
5/17/2023 JL
JKLSTRUCTURAL@GMAIL.COM
(626)524-2210
THE ENGINEER EXPRESSLY RESERVES HIS COMMON LAW
COPYRIGHT IN THESE PLANS. THESE PLANS ARE NOT TO
BE REPRODUCED, CHANGED, OR COPIED IN ANY MANNER
WHATSOEVER, NOR ASSIGNED TO ANY OTHER THIRD
PARTY WITHOUT THE EXPRESSED WRITTEN CONSENT OF
JKL ENGINEERING, INC.
SD4
ST
R
U
C
T
U
R
A
L
D
E
T
A
I
L
S
16
1
6 2
5
8
7
4
9
10
13
11
12
14
17
18
JOB NUMBER:
ENGINEER:
DRAFTER:
ORIGINAL ISSUE:
4-
U
N
I
T
C
O
N
D
O
M
I
N
I
U
M
43
G
E
N
O
A
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
21153
JL
JL
03/11/2022
1
PLAN CHECK COMMENTS
06/26/2022 JL
2
PLAN CHECK COMMENTS
5/17/2023 JL
JKLSTRUCTURAL@GMAIL.COM
(626)524-2210
THE ENGINEER EXPRESSLY RESERVES HIS COMMON LAW
COPYRIGHT IN THESE PLANS. THESE PLANS ARE NOT TO
BE REPRODUCED, CHANGED, OR COPIED IN ANY MANNER
WHATSOEVER, NOR ASSIGNED TO ANY OTHER THIRD
PARTY WITHOUT THE EXPRESSED WRITTEN CONSENT OF
JKL ENGINEERING, INC.
SD5
ST
R
U
C
T
U
R
A
L
D
E
T
A
I
L
S