Loading...
HomeMy WebLinkAbout12359 Lower Azusa Rd - 2024 - Glen Air7083;0'7083;20'7083;100'7083;50'7083;200' 9236;PROJECT NORTH 1198;BO O N E D A M 1 1 9 8 ; B O O N E D A M 1 1 9 8 ; B O O N E D A M 4618;ONLY AUTOS 2465;ONL Y TRUCKS 46 1 8 ; ON L Y AC C E S S FIR E 569 4 ; STO P 569 4 ; STO P 569 4 ; STO P 569 4 ; STO P 4167;L O W E R A Z U S A R O A D 4167;S A N G A B R I E L R I V E R 2500;BUILDING 1 9236;ROSEGLEN STREET 9236;HALLWOOD DRIVE 9236;CHERRYLEE DR. 9236;HEMLOCK ST. 0625;BASIN 4 0625;BASIN 3 2500;BUILDING 2 2500;BLDG 3 0625;Q U A R R Y D R I V E 2465;FIRE GATE2465;FIREGATE 0625;BASIN 5 0625;BASIN 2 0625;BASIN 1 3542;FP 35 4 2 ; ELE C 3542;FP3542;ELEC 3542;FP 354 2 ; ELE C 2465;FIRE GATE 2465;FIRE GATE 8472;FLOOR SLAB SLOPE 0.5% MAX - SEE CIVIL 8472;FLOOR SLAB SLOPE 0.5% MAX - SEE CIVIL 8472;FLAT FLOOR SLAB - NO SLOPE 0625;BASIN 6 2465;FIRE GATE AREA OF WORK SPECIFIC PLAN MITIGATION MEASURES MM 4.2-1 PRIOR TO BUILDING PERMIT ISSUANCE, THE CITY OF ARCADIA SHALL VERIFY THAT THE FOLLOWING NOTE IS SPECIFIED ON ALL BUILDING PLANS. PROJECT CONTRACTORS SHALL BE REQUIRED TO COMPLY WITH THE NOTE AND MAINTAIN WRITTEN RECORDS OF SUCH COMPLIANCE THAT CAN BE INSPECTED BY THE CITY OF ARCADIA UPON REQUEST. THIS NOTE ALSO SHALL BE SPECIFIED IN BID DOCUMENTS ISSUED TO PROSPECTIVE CONSTRUCTION CONTRACTORS. “ALL SURFACE COATINGS SHALL CONSIST OF “ZERO-VOLATILE ORGANIC COMPOUND”PAINTS (NO MORE THAN 100 GRAM/LITER OF VOC) AND/OR HIGH PRESSURE LOW VOLUME (HPLV) APPLICATIONS CONSISTENT WITH SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1113.” MM 4.2-7 THE BUILDING PLANS FOR EACH BUILDING SHALL REQUIRE LIGHT-COLORED ROOF MATERIALS. LIGHT COLORED ROOF MATERIALS ARE MORE SOLAR-REFLECTIVE THAN DARK COLORED ROOFS; LIGHT COLOR ROOFS KEEP BUILDINGS COOLER AND REDUCE LOCAL AIR TEMPERATURES, WHICH IN TURN IMPROVES AIR QUALITY AND SLOWS SMOG FORMATION. THE CITY OF ARCADIA SHALL VERIFY THIS INFORMATION IS PROVIDED ON THE PROJECT’S BUILDING PLANS PRIOR TO ISSUANCE OF BUILDING PERMITS AND INSPECT FOR ADHERENCE DURING BUILDING CONSTRUCTION. MM 4.5-1 PRIOR TO BUILDING PERMIT ISSUANCE, THE CITY OF ARCADIA SHALL VERIFY THAT THE FOLLOWING NOTES ARE SPECIFIED ON ALL BUILDING PLANS. PROJECT CONTRACTORS SHALL BE REQUIRED TO COMPLY WITH THE NOTES AND MAINTAIN WRITTEN RECORDS OF SUCH COMPLIANCE THAT CAN BE INSPECTED BY THE CITY OF ARCADIA UPON REQUEST. THESE NOTES ALSO SHALL BE SPECIFIED IN BID DOCUMENTS ISSUED TO PROSPECTIVE CONSTRUCTION CONTRACTORS. A) COMPREHENSIVE CONSTRUCTION MANAGEMENT PLAN SHALL BE PREPARED AND IMPLEMENTED THAT IS DESIGNED TO MINIMIZE THE NUMBER OF LARGE CONSTRUCTION EQUIPMENT OPERATING DURING ANY GIVEN TIME PERIOD. B) GASOLINE-POWERED EQUIPMENT SHALL BE EQUIPPED WITH CATALYTIC CONVERTERS. C) ELECTRICAL POWERED EQUIPMENT SHALL BE UTILIZED IN-LIEU OF GASOLINE-POWERED ENGINES WHERE FINANCIALLY AND TECHNICALLY FEASIBLE AND COMMERCIALLY AVAILABLE. PROVIDE TEMPORARY TRAFFIC CONTROLS SUCH AS A FLAG PERSON, DURING ALL PHASES OF CONSTRUCTION TO MAINTAIN SMOOTH TRAFFIC FLOW ON PUBLIC STREETS ADJACENT TO THE PROJECT SITE. MM 4.5-2 BUILDING AND SITE PLAN DESIGNS SHALL ENSURE THAT PROJECT ENERGY EFFICIENCIES SURPASS (EXCEED) APPLICABLE (2014) CALIFORNIA TITLE 24 ENERGY EFFICIENCY STANDARDS BY A MINIMUM OF 5%. VERIFICATION OF INCREASED ENERGY EFFICIENCIES SHALL BE DOCUMENTED IN TITLE 24 COMPLIANCE REPORTS PROVIDED BY THE APPLICANT, AND REVIEWED AND APPROVED BY THE CITY OF ARCADIA PRIOR TO THE ISSUANCE OF THE FIRST BUILDING PERMIT. MM 4.9-2 PRIOR TO THE ISSUANCE OF ANY BUILDING OR GRADING PERMITS, THE CITY OF ARCADIA DEVELOPMENT SERVICES DEPARTMENT SHALL REVIEW BUILDING AND GRADING PLANS TO ENSURE THAT THE FOLLOWING NOTES ARE INCLUDED. PROJECT CONTRACTORS SHALL BE REQUIRED TO COMPLY WITH THESE NOTES AND MAINTAIN WRITTEN RECORDS OF SUCH COMPLIANCE THAT CAN BE INSPECTED BY THE CITY OF ARCADIA UPON REQUEST. A) CONSTRUCTION CONTRACTORS SHALL EQUIP ALL CONSTRUCTION EQUIPMENT, FIXED OR MOBILE, WITH PROPERLY OPERATING AND MAINTAINED MUFFLERS, CONSISTENT WITH MANUFACTURERS’STANDARDS. THE CONSTRUCTION CONTRACTOR SHALL PLACE ALL STATIONARY CONSTRUCTION EQUIPMENT SO THAT EMITTED NOISE IS DIRECTED AWAY FROM THE NOISE SENSITIVE RECEPTORS NEAREST THE PROJECT SITE. B) CONSTRUCTION CONTRACTORS SHALL LOCATE EQUIPMENT STAGING AREAS (AREAS WHERE LARGE PIECES OF CONSTRUCTION EQUIPMENT ARE STORED WHEN NOT IN OPERATION) A MINIMUM DISTANCE OF 200 FEET AWAY FROM NOISE-SENSITIVE RECEIVERS NEAREST THE PROJECT SITE (I.E., TO THE WEST) DURING ALL PROJECT CONSTRUCTION. C) CONSTRUCTION CONTRACTORS SHALL LIMIT HAUL TRUCK DELIVERIES TO THE SAME HOURS SPECIFIED FOR CONSTRUCTION EQUIPMENT (BETWEEN THE HOURS OF 7:00 A.M. AND 7:00 P.M., MONDAY THROUGH SATURDAY, UNLESS OTHERWISE PERMITTED BY THE DEVELOPMENT SERVICES DEPARTMENT. CONSTRUCTION IS PROHIBITED ON SUNDAYS AND MAJOR HOLIDAYS.). D) TO LIMIT HAUL TRUCK NOISE TO SENSITIVE RECEPTORS, HAUL TRUCKS MUST ENTER AND LEAVE THE PROJECT SITE BY LOWER AZUSA ROAD, TOWARD I-605. HAUL TRUCKS SHALL NOT BE PERMITTED TO LEAVE THE SITE AND TURN RIGHT ON LOWER AZUSA ROAD. SIGNS MUST BE INSTALLED AT ALL CONSTRUCTION EXIT DRIVEWAYS DIRECTING DRIVERS TO TURN LEFT ONTO LOWER AZUSA ROAD TOWARD I-605. E) ANY PROJECT-RELATED CONSTRUCTION ACTIVITY PLANNED DURING THE EVENING (7:00 P.M. TO 10:00 P.M.) OR LATE NIGHT/EARLY MORNING HOURS (10:00 P.M. TO 7:00 A.M.) REQUIRES DISCLOSURE TO ALL PROPERTIES WITHIN 300 FEET, AND/OR AS OTHERWISE REQUIRED BY THE CITY OF ARCADIA OR REQUESTED BY THE CITY OF EL MONTE, AND SHALL NOT TAKE PLACE WITHIN 40 FEET OF NEARBY SENSITIVE RECEIVERS. TO CONDUCT WORK DURING THESE EVENING AND LATE NIGHT/EARLY MORNING HOURS, THE CONSTRUCTION CONTRACTOR MUST DEMONSTRATE TO THE CITY OF ARCADIA IN THE FORM OF A NOISE ANALYSIS PREPARED BY A QUALIFIED ACOUSTICAL ENGINEER THAT CONSTRUCTION NOISE LEVELS AFFECTING RESIDENTIAL RECEIVERS IN THE CITY OF EL MONTE BETWEEN 7:00 P.M. AND 7:00 A.M. WOULD FALL AT OR BELOW THE FOLLOWING LEVELS: 45 LEQ AVERAGE; 50 L25 (15 MINUTE); 55 L8 (5 MINUTE) AND 60 LMAX (<1 MINUTE). MM 4.10-4 PRIOR TO THE ISSUANCE OF GRADING OR BUILDING PERMITS, THE PROJECT APPLICANT SHALL PREPARE AND THE CITY OF ARCADIA SHALL APPROVE A TEMPORARY TRAFFIC CONTROL PLAN. THE TEMPORARY TRAFFIC CONTROL PLAN SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. A REQUIREMENT TO COMPLY WITH THE TEMPORARY TRAFFIC CONTROL PLAN SHALL BE NOTED ON ALL GRADING AND BUILDING PLANS AND ALSO SHALL BE SPECIFIED IN BID DOCUMENTS ISSUED TO PROSPECTIVE CONSTRUCTION CONTRACTORS. THE TEMPORARY TRAFFIC CONTROL PLAN SHALL REQUIRE THE FOLLOWING: A) DELIVERY TRUCKS SHALL UTILIZE THE MOST DIRECT ROUTE BETWEEN THE SITE AND I-605 VIA LOWER AZUSA ROAD; B) EXCEPT FOR THE SEGMENT OF LOWER AZUSA ROAD BETWEEN THE SITE AND I-605, THE CONSTRUCTION CONTRACTOR SHALL ASSURE THAT CONSTRUCTION-RELATED HAUL TRIPS, INCLUDING BUT NOT LIMITED TO THE TRANSPORTATION OF CONSTRUCTION MATERIALS, EARTH MATERIALS, AND/OR HEAVY EQUIPMENT TO AND FROM THE PROJECT SITE BE LIMITED TO NO MORE THAN 50 PASSENGER CAR EQUIVALENT (PCE) TRIPS (I.E., 25 INBOUND AND 25 OUTBOUND TRIPS, OR ANY COMBINATION THEREOF) DURING THE AM PEAK HOUR (7:00AM-9:00AM) AND THE PM PEAK HOUR (4:00PM-6:00PM) ON LOCAL ROADS. A TWO-AXLE TRUCK TRIP IS THE EQUIVALENT OF 1.5 PCE TRIPS; A THREE-AXLE TRUCK TRIP IS THE EQUIVALENT OF 2.0 PCE TRIPS; AND A FOUR-AXLE OR LARGER TRUCK TRIP IS THE EQUIVALENT OF 3.0 PCE TRIPS. RR-NOISE-4 PRIOR TO ISSUANCE OF DISCRETIONARY PERMITS FOR CONSTRUCTION ACTIVITIES, PROJECT APPLICANTS/DEVELOPERS SHALL SUBMIT EVIDENCE TO THE DIRECTOR OF DEVELOPMENT SERVICES THAT THE FOLLOWING NOISE REDUCTION MEASURES ARE STATED AS REQUIREMENTS ON THE CONSTRUCTION PLANS AND SPECIFICATIONS: A) DURING ALL EXCAVATION AND GRADING, THE CONSTRUCTION CONTRACTORS SHALL EQUIP ALL CONSTRUCTION EQUIPMENT, FIXED OR MOBILE, WITH PROPERLY OPERATING AND MAINTAINED MUFFLERS, CONSISTENT WITH MANUFACTURERS’STANDARDS. THE CONSTRUCTION CONTRACTOR SHALL PLACE ALL STATIONARY CONSTRUCTION EQUIPMENT SO THAT EMITTED NOISE IS DIRECTED AWAY FROM THE NOISE-SENSITIVE RECEPTORS. B) WHEN FEASIBLE, THE CONSTRUCTION CONTRACTOR SHALL LOCATE EQUIPMENT STAGING IN AREAS THAT WILL CREATE THE GREATEST DISTANCE BETWEEN CONSTRUCTION-RELATED NOISE SOURCES AND NOISE SENSITIVE RECEPTORS DURING ALL PROJECT CONSTRUCTION. C) THE CONSTRUCTION CONTRACTOR SHALL LIMIT ALL CONSTRUCTION-RELATED ACTIVITIES THAT WOULD RESULT IN HIGH NOISE LEVELS, ACCORDING TO THE CONSTRUCTION HOURS SET FORTH IN THE MUNICIPAL CODE. D) THE CONSTRUCTION CONTRACTOR SHALL LIMIT HAUL TRUCK DELIVERIES TO THE SAME HOURS SPECIFIED FOR CONSTRUCTION EQUIPMENT. TO THE EXTENT FEASIBLE, HAUL ROUTES SHALL NOT PASS SENSITIVE LAND USES OR RESIDENTIAL DWELLINGS. PROJECT SITE T.O.W. TYP. T.S.B. T.O.S. T.O.P. T.O.R. T.S. T.O.C. T.O.CL. REF. S.G. S.F. SS S M.T. F.D. H.B. F.E. F.S. FHC F.O.S. F.E.W. F.F. F.O.C. F.S.S. B.O.B. F.O.B. EXP. (E) DF LC A.F.L. B.W. A.F.F. F.E.B. OCC. OL EXIT BATTERY BACK UP EMERGENCY LIGHT W/EXIT COMBINATION, REFER TO ELECTRICAL FOR PLACEMENT SURFACE MOUNTED ILLUMINATED EXIT SIGN WITH DIRECTIONAL ARROWS IF APPLICABLE -WHERE INDICATED. UNLESS OTHERWISE NOTED.W/ 2A:10B:C TOP OF SPANDREL BEAM TOP OF WALL TYPICAL TOP OF SLAB TOP OF SHEATHING TOP OF CLADDING TOP OF RAILING TOP OF PARAPET TOP OF CURB REFRIGERATOR SLAB ON GRADE SQUARE FEET SERVICE SINK SINK MARBLE THRESHOLD FIRE EXTINGUISHER CABINET FINISH SURFACE FIRE HOSE CABINET FLOOR DRAIN HOSE BIB FACE OF CONCRETE FACE OF STUD FACE OF EXISTING WALL FACE OF STUCCO SURFACE FINISH FLOOR BOTTOM OF BEAM FACE OF BLOCK DRINKING FOUNTAIN EXPOSED EXISTING CENTER LINE BACK OF WALK ABOVE FINISH LEVEL ABOVE FINISH FLOOR FIRE EXTINGUISHER BRACKET MOUNTED OCCUPANCY OCCUPANCY LOAD UNLESS OTHERWISE NOTED.W/ 2A:10B:C EMERGENCY LIGHT, REFER TO ELECTRICAL FOR PLACEMENT EXIT E.EMERGENCY LIGHTING W/ 90MIN. BATTERY BACKUP. CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . By Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 1/ 2 5 / 2 0 2 4 3: 0 0 : 4 4 P M 1/25/2024 3:00:44 PM T15-1.0 CO V E R P A G E 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - BL D G 2 11 / 1 0 / 2 3 Au t h o r Ch e c k e r GLENAIR LOGISTICS -BUILDING 2 12359 LOWER AZUSA ROAD ARCADIA, CA 91006 APPLICABLE CODES:2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA ELECRTICAL CODE (CEC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING STDS. 2022 CALIFORNIA FIRE CODE (CFC) ZONE:ARCADIA LOGISTICS CENTER SPECIFIC PLAN AREA OF LOT: LEGAL DESCRIPTION: ASSESSOR'S ID NO. : OCCUPANCY TYPE: BUILDING SPRINKLER: PHASE XV -PROPOSED INTERIOR RENOVATIONS 644,026 SF 14.75 ACRES 8541-017-027 AND 8541-017-028 B / S-1 / F-2 / A-2 THE LAND REFFERED TO HEREIN BELOW IS SITUATED IN THE CITY OF ARCADIA, IN THE COUNTY OF LOS ANGELES, STATE OF CALIFORNIA , AND IS DESCRIBED AS FOLLOWS. THAT PORTION OF LOT 1 OF TRACT NO. 10369, IN THE CITY OF ARCADIA, COUNTY OF LOS ANGELES, STATE OF CALIFORNIA, AS PER MAP RECORD IN BOOK 149, PAGES 95 AND 96, OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY, LYING WESTERLY AND NORTHWESTERLY OF THE WESTERLY LINE OF THE LAND DESCRIBED IN THE CONDEMNATION OF ACTION , CASE NO. 574211, SUPERIOR COURT OF SAID COUNTY, A CERTIFIED COPY OF THE DECREE HAD IN SAID ACTION WAS RECORDED IN BOOK 38373, PAGE 153, OF OFFICE RECORDES. EXCEPT AN UNDIVIDED 75 PER CENT OF ALL OIL, GAS AND OTHER HYDROCARBON SUBSTANCES IN AND UNDER SAID LAND, WITH RIGHT OF INGRESS AND EGRESS NECESSARY FOR THE MINING AND REMOVAL OF SAME, AS RESERVED BY MARTIN WUNDERLICH, E.MURIELLE WUNDERLICH, GEORGE P. LEONARD AND WILM LEONARD, BY DEED RECORDED FEBRUARY 4, 1955 AS INSTRUMENT NO. 470, IN BOOK 46821, PAGE 149, OF OFFICIAL RECORDES. FULLY SPRINKLERED ESFR SITE INFORMATION CODE SUMMARY PROJECT DATA CONSTRUCTION TYPE:TYPE III-B AREA JUSTIFICATION:UNLIMITED FOUR SURROUNDING SIDEYARDS OF 40' AND 60' PER CBC 507 AND 507.5 BUILDING CODE ALLOW HEIGHT: 50' + 20' = 70 FEET -SECTION 504.2 PROJECT SCOPE OF WORK PARKING REQUIRED: EXISTING LANDSCAPE AREA: 23,032 SF OFFICE @ 1/250 (E) BUILDING AREA: 331,683 SFGROUND FLOOR: 9,175 SFMEZZANINE: 340,858 SF 92 STALLS 10,000 SF WH/MANUF (0K-10K) @ 1/1,000 10 STALLS 10,000 SF WH/MANUF (10K-20K) @ 1/3,000 3 STALLS 297,826 SF WH/MANUF (20K+) @ 1/5,000 60 STALLS 165 STALLSTOTAL PARKING REQUIRED: 79,745 SF COVERAGE:12.38% PREFERED PARKING STALLS REQUIRED FOR LOW EMITTING & FUEL EFFICIENT VEHICLES PER CALGREEN TABLE 5.106.5.2 16 STALLS EXISTING PARKING STALLS REQUIRED FOR LOW EMITTING & FUEL EFFICIENT VEHICLES PER CALGREEN TABLE 5.106.5.2 18 STALLS BIKE PARKING REQUIRED: 9 BIKESCALGREEN @ MIN. 5% OF AUTO STALLS PROVIDED: EXISTING BIKE PARKING :10 BIKES EXISTING ACCESSIBLE STALLS: STANDARD: VAN: 5 6 11TOTAL: CONSULTANT INDEX:SHEET INDEX:LEGENDS AND ABBREVIATION INDEX SITE PLAN VICINITY MAP STRUCTURAL ELECTRICAL MECHANICAL TENANT: DEVELOPER: ARCHITECT: STRUCUTRAL ENGINEER: PROJECT DEVELOPER: ELECTRICAL ENGINEER: GLENAIR, INC. 1211 AIR WAY GLENDALE, CA 91201 (818) 247-6000 GEORGE C. HOPKINS 919 W. GLENOAKS BLVD. GLENDALE, CA 91202 (818) 956-0533 GEROGE C. HOPKINS CONSTRUCTION 919 WEST GLENAOKS BLVD. GLENDALE, CA 91202 ALEN MALEKIAN, AIA 2255 HONOLULU AVE. , SUITE 1A MONTROSE, CA 91020 (818) 249-5522 KENT ELECTRIC, INC. 6655 SAN FERNANDO ROAD GLENDALE, CA 91201 (818) 247-1192 GROSSMAN & SPEER ASSOCIATES, INC. 529 HAHN AVE., SUITE 200 GLENDALE, CA 91203 (818) 507-1020 THERMA 2390 BATEMAN AVE. IRWINDALE, CA 91010 (626) 446-1854 MECHANICAL: -INTERIOR RENOVATIONS; THAD ROOM ADDITION (NO CHANGE IN EXISTING BUILDING AREA) AREA OF WORK BETWEEN GRID LINES D / E & 13 / 14 (1,866 SF) EXISTING PARKING:(TOTAL)439 STALLS EXISTING EV PARKING :10 STALLS S15-1.0 GENERAL NOTES PARTIAL FLOOR PLAN S15-2.0 DETAILS AND SECTIONS M15-1.0 MECHANICAL COVER SHEET -PHASE XV M15-2.0 PARTIAL HVAC FLOOR PLAN -PHASE XV M15-3.0 COMPLIANCE ENERGY FORMS -PHASE XV E1.0 ELECTRICAL LIGHTING AND POWER PLANS T24-1 ENERGY FORMS T15-1.0 COVER PAGE T15-1.1 GENERAL NOTES T15-1.2 CALGREEN NOTES T15-1.3 CALGREEN NOTES T15-1.4 CALGREEN NOTES T15-1.5 OCCUPANCY AND EXITING DIAGRAM T15-1.6 FIRE EXTINGUISHER PLAN A15-1.0 SITE PLAN A15-2.1 PROPOSED FLOOR PLAN A15-2.2 PROPOSED RCP A15-2.3 ENLARGED PLANS A15-3.0 INTERIOR ELEVATIONS & SECTIONS A15-5.0 DOOR AND WINDOW SCHEDULE A15-5.1 FINISH SCHEDULE AND NOTES A15-6.0 DETAILS A15-6.1 CEILING DETAILS THE GENERAL CONTRACTOR AND ALL SUB-CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON THE JOB SITE PRIOR TO BEGINNING CONSTRUCTION AND SHALL REPORT ANY DISCREPANCIES OR UNIDENTIFIED CONDITIONS TO THE ARCHITECT FOR RESOLUTION BEFORE ANY WORK IS BEGUN. DIMENSIONS, DETAILS, NOTES AND/OR SYMBOLS THAT APPLY TO ONE UNIT, APPLY TO ALL UNITS IN LIKE SITUATIONS UNLESS NOTED OTHERWISE. 3. ALL WORK SHALL CONFORM TO ALL APPLICABLE BUILDING CODES, ORDINANCES AND REGULATIONS AS ADOPTED BY LOCAL AUTHORITIES HAVING JURISDICTION. 4. 5. 1. PROVIDE LOW CONSUMPTION WATER CLOSET FOR NEW BUILDING, BUILDING ADDITION OR BUILDING REMODELING WHERE NEW PLUMBING FIXTURES WILL BE INSTALLED. MECHANICAL HVAC SYSTEM AND ENERGY CONSERVATION CALCS TO BE SUBMITTED TO AND APPROVED BY MECHANICAL DIVISION PRIOR TO INSTALLATION. ALL EXPOSED GYPSUM BOARD SOFFITS AND CEILING -5/8" GYPSUM BOARD OR 5/8" TYPE 'X' WHERE NOTED. ITEMS MARKED "OFCI" REFER TO ITEMS FURNISHED BY OWNER AND INSTALLED AND CONNECTED BY THE CONTRACTOR. (OWNER FURNISHED, CONTRACTOR INSTALLED). ALL CEILING GRILLES SHALL BE COORDINATED WITH CEILING LAYOUT, IF APPLICABLE. PROVIDE NEW FIRE EXTINGUISHERS IF INDICATED OR REQUIRED. EXTINGUISHERS SHALL BE 5 GAL., TYPE 2A10BC IN RECESSED CABINETS. FIRE EXTINGUISHERS TO BE TYPE 10BC FOR ELECTRICAL AND MECHANICAL ROOMS AND SHALL BE SURFACE MOUNTED ON HANGER BRACKETS.PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR. INTERIOR WALL AND CEILING FINISH FOR EXIT CORRIDORS SHALL NOT EXCEED AN END POINT FLAME SPREAD RATING OF CLASS II (26-75) AND SMOKE DENSITY OF 300. ROOM AREAS SHALL NOT EXCEED END POINT FLAME SPREAD RATING OF CLASS III (76-200) AND SMOKE DENSITY OF 450. CURTAIN, DRAPES, SHADES, ETC. SHALL BE NON-COMBUSTIBLE AS REQUIRED BY THE GOVERNING AGENCIES. ALL EXIT DOORS TO BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF KEY OR SPECIAL KNOWLEDGE OR EFFORT. FLUSH BOLTS OR SURFACE BOLTS ARE PROHIBITED. ALL INTERIOR NON-BEARING WALLS METAL STUDS AT 16" O.C., UNLESS NOTED OTHERWISE, WITH GYPSUM BOARD EACH SIDE. DETAILS NOTED AS 'TYPICAL' SHALL APPLY IN ALL LIKE CONDITIONS UNLESS SPECIFICALLY SHOWN OR NOTED OTHERWISE. WHERE NO SPECIFIC DETAIL IS SHOWN, THE FRAMING OR CONSTRUCTION SHALL BE IDENTICAL OR SIMILAR TO THAT INDICATED FOR LIKE CASES OF CONSTRUCTION OF THIS PROJECT. WHENEVER AN ARTICLE, DEVICE, OR PIECE OF EQUIPMENT IS SHOWN, INDICATED, OR REFERRED TO ON THE DRAWINGS OR THESE NOTES IN THE SINGULAR NUMBER, SUCH REFERENCES APPLY TO AS MANY SUCH ARTICLES AS ARE REQUIRED TO COMPLETE THE INSTALLATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS, METHODS, TECHNIQUES AND PROCEDURES EMPLOYED IN THE PERFORMANCE OF WORK IN, ON OR ABOUT THE JOB SITE; THE CONTRACTOR SHALL COORDINATE AND VERIFY ALL WORK PERFORMED BY SUB-CONTRACTORS. ALL CONTRACTORS AND SUB-CONTRACTORS PERFORMING WORK ON, OR RELATED TO THIS PROJECT SHALL CONDUCT THEIR OPERATIONS SO THAT ALL EMPLOYEES ARE PROVIDED A SAFE PLACE TO WORK AND THE PUBLIC IS PROTECTED, AND SHALL COMPLY WITH THE 'OCCUPATIONAL SAFETY AND HEALTH REGULATION' OF THE U.S. DEPARTMENT OF LABOR AND WITH ANY AND ALL OTHER APPLICABLE STATE AND/OR LOCAL SAFETY REGULATIONS. THE CONTRACTOR AGREES TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE SAFETY CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT; THAT THISREQUIREMENT SHALL APPLY CONTINUALLY AND NOT BE LIMITED TO NORMAL WORKINGHOURS AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD HARMLESS THE OWNER AND ARCHITECT FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH PERFORMANCE OF WORK ON THIS PROJECT. THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS IS TO INCLUDE ALL LABOR, MATERIALS AND SERVICES NECESSARY FOR COMPLETION OF ALL WORK SHOWN, PRESCRIBED, OR REASONABLY IMPLIED BUT NOT LIMITED TO THAT EXPLICITLY INDICATED IN THE CONTRACT DOCUMENTS. 2. DIMENSIONS ON DRAWINGS ARE SHOWN TO CENTERLINE OF COLUMNS AND WALLS AND FACE OF MASONRY/CONCRETE UNLESS INDICATED OTHERWISE. DO NOT SCALE DRAWINGS. STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, CIVIL, AND LANDSCAPE DRAWINGS ARE SUPPLEMENTAL TO THE ARCHITECTURAL DRAWINGS. THE CONTRACTOR SHALL REVIEW ALL PLANS AND DRAWINGS. IN THE EVENT OFCONFLICTING STATEMENTS, INSUFFICIENT INFORMATION OR ERRORS, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND OBTAIN CLARIFICATION BEFORE ANY WORK IS BEGUN. WORK INSTALLED WHERE CONFLICTING CONDITIONS EXIST SHALL BE CORRECTED AT CONTRACTORS EXPENSE. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 24. 25. 26. 22. 23. WHEN SERVING MORE THAN 20 SPRINKLER HEADS, AUTOMATIC SPRINKLER SYSTEMS SHALL BE SUPERVISED BY AN APPROVED CENTRAL, PROPRIETARY OR REMOTE, STATION SERVICE, OR SHALL BE PROVIDED WITH A LOCAL ALARM WHICH WILL GIVE AN AUDIBLE SIGNAL AT A CONSTANTLY ATTENDED LOCATION. "PER SECTION 904.3.1. 21. SEPARATE PERMITS SHALL BE REQUIRED FOR ALL GRADING, FIRE ALARMS, FIRE UNDERGROUND & HYDRANTS, FIRE SPRINKLER SYSTEMS, AND TENANT SIGNAGE. A LANDSCAPING PLAN SHALL BE SUBMITTED TO TEH CITY FOR APPROVAL PRIOR TO ISSUANCE OF BUILDING PERMITS AND SHALL BE IMPLEMENTED PRIOR TO OCCUPANCY. THE PROJECT DOES NOT PROPOSE ANY TENANT SIGNAGE AT THIS TIME. SIGNAGE MAY BE SUBMITTED AT A LATER DATE. THE SITE CONTAINS NO EXISTING PROTECTED TREES TO BE REPLANTED OR REPLACED. THERE ARE NO PROTECTED PLANTS ON SITE. THIS BUILDING IS DESIGNED FOR HIGH PILE STORAGE. A SEPARATE PERMIT FROM THE BUILDING & FIRE DEPARTMENTS IS REQUIRED FOR HIGH PILE STORAGE WITHIN THE FACILITY. SPECIAL INSPECTION NOTES SPECIFIC TO THIS PROJECT MAY BE FOUND ON SHEET ____ OF THE STRUCTURAL PORTION OF THIS PACKAGE. 27. NO HAZARDOUS MATERIALS SHALL BE STORED AND/OR USED WITHIN THE BUILDING WHICH EXCEED THE QUANTITIES LISTED IN CBC TABLES 307.1(1) AND 307.2(2) 28. WHETHER OR NOT DETAILED ON THE DRAWINGS, THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL STIFFENERS, BRACING, BACK-UP PLATES AND SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF ALL CASEWORK AND OF ALL WALL MOUNTED OR SUSPENDED MECHANICAL, ELECTRICAL, OR MISCELLANEOUS EQUIPMENT INCLUDING PLYWOOD BACKBOARDS FOR TELEPHONE AND ELECTRICAL EQUIPMENT ROOMS. 29. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING APPROVAL AND PERMITS FOR ALL DESIGN/BUILD SYSTEMS. HE SHALL ALSO BE RESPONSIBLE FOR INSURING THAT THE SYSTEMS MEET ALL APPLICABLE CODE REQUIREMENTS. 30. ANY MODIFICATIONS TO THE BUILDING SHELL RESULTING FROM DESIGN/BUILD REQUIREMENTS SHALL BE REPORTED TO THE OWNER AND ARCHITECT ALONG WITH ANY REQUIRED COSTS OR SAVINGS PRIOR TO CONSTRUCTION. ANY MODIFICATIONS NOT REPORTED WILL BE THE CONTRACTORS RESPONSIBILITY FOR COORDINATION, CODE CONFORMANCE, AND COST. 31. NEITHER THE ARCHITECT'S REVIEW OR APPROVAL OF SHOP DRAWINGS SHALL RELIEVE THE GENERAL CONTRACTOR FROM RESPONSIBILITY FOR DEVIATIONS FROM DRAWINGS OR SPECIFICATIONS UNLESS HE HAS CALLED THE ARCHITECT'S ATTENTION IN WRITING TO SUCH DEVIATIONS AT THE TIME OF SUBMISSION NOR SHALL IT RELIEVE HIM OF RESPONSIBILITY FOR ERRORS OF ANY SORT IN THE SHOP DRAWINGS. 32. INSTALLATION OF GLASS SHALL CONFORM TO FEDERAL SPECIFICATION 16-CFR-1202 AND ALL LOCAL CODES AND ORDINANCES. GLASS SUBJECT TO HUMAN IMPACT SHALL COMPLY WITH U.S. CONSUMER PRODUCT SAFETY STANDARDS. A CERTIFICATE SHALL ACCOMPANY PRODUCT STATING DATE AND PLACE OF MANUFACTURE. ALL GLAZING SHALL BE TEMPERED WHEN REQUIRED BY CHAPTER 24. 33. REFER TO THE CIVIL ENGINEER'S DRAWINGS FOR LOCATIONS OF EXISTING UTILITY LINES. LOCATIONS OF ALL UTILITIES SHOWN ARE APPROXIMATE AND THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION IN EXCAVATION AND TRENCHING TO AVOID INTERCEPTING EXISTING PIPING OR CONDUITS. 34. THE CONTRACTOR SHALL SUBMIT A SOILS REPORT AND A COMPACTION REPORT TO THE BUILDING DEPARTMENT FOR APPROVAL PRIOR TO FOUNDATION INSPECTIONS. 35. LOCATIONS OF ALL UTILITIES SHOWN ON THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION IN EXCAVATION AND TRENCHING TO AVOID INTERCEPTING EXISTING PIPING OR CONDUITS. THE CONTRACTOR IS RESPONSIBLE TO VERIFY LOCATION OF ALL SITE UTILITIES AND TO COORDINATE AND AVOID CONFLICT IN THE LOCATIONS OF NEW UNDERGROUND AND SITE UTILITIES. 36. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND ARCHITECT SHOULD UNIDENTIFIED FIELD CONDITIONS BE DISCOVERED. 37. ON A SET OF TRANSPARENCIES, FURNISHED BY THE ARCHITECT AT THE CONTRACTOR'S EXPENSE, THE CONTRACTOR SHALL KEEP AN UP-TO-DATE RECORD OF 'AS BUILT' CONDITIONS OF THE WORK. UPON COMPLETION OF THE WORK, THE SET SHALL BE RETURNED TO THE ARCHITECT COMPLETELY AND NEATLY POSTED SHOWING ALL ADDITIONS, DELETIONS, CORRECTIONS, AND REVISIONS IN THE ACTUAL CONSTRUCTION OF THE PROJECT. RECORD DRAWINGS SHALL BE SIGNED BY THE SUB- CONTRACTORS REPRESENTING ALL MAJOR TRADES FOR THE PROJECT AS WELL AS THE GENERAL CONTRACTOR. 38. WHEN REQUESTED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING, MOUNTING, AND DISPLAYING ARCHITECT'S JOB SIGN. CONTRACTOR SHALL ALSO RETURN THE JOB SIGN TO ARCHITECT AT COMPLETION OF PROJECT IN GOOD CONDITION. 39. SEE WALL LEGENDS OR CALLOUTS ON PLANS FOR WALL FRAMING MEMBERS, FIRE RATINGS, GYPSUM BOARD THICKNESSES AND OTHER WALL CONSTRUCTION MATERIALS. PROVIDE AND INSTALL HEAVIER GAUGE STUDS, STIFFENERS, BRACING, BACK-UP PLATES, ETC. AS REQUIRED IN STUD WALLS FOR THE SUPPORT OF TOILET ROOM FIXTURES AND OTHER WALL MOUNTED EQUIPMENT. 40. 41. ALL GYPSUM BOARD USED IN JANITOR'S ROOMS AND ALL TOILET ROOMS SHALL BE WATER RESISTANT EXCEPT AT CEILINGS PER THE 2016 CBC. CHAPTER 25. ALL ROOFING MATERIALS SHALL COMPLY WITH ALL APPLICABLE STANDARDS LISTED IN 2016 CBC. CHAPTER 15. 42. 43. 44. 45. 46. 48. PRIOR TO ERECTION, THE CONTRACTOR SHALL SUPPLY THE BUILDING INSPECTOR WITH AN A.I.T.C. CERTIFICATE OF COMPLIANCE FOR THE STRUCTURAL GLU-LAMINATED MEMBERS WHEN USED. IN ACCORDANCE WITH CBC SECTION 1008, EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. IN GROUP B OCCUPANCIES AT THE MAIN ENTRANCE ONLY, PROVIDE SIGNAGE STATING IN 1" HIGH LETTER " THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" THE LOCKING DEVICE SHALL BE OF A TYPE READILY DISTINGUISHABLE AS LOCKED. EXIT DOORS MUST OPEN OVER A LANDING NOT MORE THAN 1/2" BELOW THE THRESHOLD AND THE DOOR SHALL SWING IN THE DIRECTION OF EXIT TRAVEL WHEN SERVING AN OCCUPANT LOAD OF 50 OR MORE. EXIT DOORS SHALL BE NOT LESS THAN 3'-0" IN WIDTH AND 6'-8" IN HEIGHT AND NO SINGLE LEAF SHALL EXCEED 4'-0" IN WIDTH. 47. THE FLOOR ADJACENT TO ANY DOORWAY SHALL BE LEVEL (1/4" PER FOOT MAX. FOR EXTERIOR CONDITIONS) FOR A DISTANCE OF FIVE FEET FROM THE DOOR IN THE DIRECTION OF THE DOOR SWING AND SHALL NOT BE LESS THAN FIVE FEET WIDE. EXIT SIGNS SHALL BE PROVIDED AT ALL REQUIRED EXIT DOORS AND IN OTHER LOCATIONS WHERE REQUIRED BY, AND IN ACCORDANCE WITH, APPLICABLE LAWS. THE PRINCIPAL STROKE OF SUCH SIGNS SHALL BE NOT LESS THAN 3/4" WIDE AND 6" TALL. 49. EXIT SIGNS SHALL BE INTERNALLY ILLUMINATED PER 2016 CBC SECTION 1013 AND SHALL BE LISTED FOR THEIR USE. 50. EXIT SIGNS SHALL BE PROVIDED WITH AN EMERGENCY SOURCE OF SELF CONTAINED POWER PER 2016 CBC CHAPTER 10 AND THEY SHALL BE INSTALLED PER THE ELECTRICAL CODE. 51. THE POWER FOR MEANS OF EGRESS ILLUMINATION SHALL BE IN ACCORDANCE WITH 2016 CBC CHAPTER 10. ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR OTHERS, AND THOSE SHOWN ON THE RECORDS EXAMINED, ARE INDICATED BY APPROXIMATE LOCATION AND EXTENT. THE OWNER AND CONTRACTOR, BY ACCEPTING THESE PLANS OR PROCEEDING WITH IMPROVEMENTS HERETO, AGREES TO ASSUME LIABILITY AND HOLD THE ARCHITECT HARMLESS FOR ANY DAMAGES RESULTING FROM THE EXISTENCE OF UNDERGROUND UTILITIES OR STRUCTURES NOT REPORTED BY THE ARCHITECT, NOT INDICATED ON THE RECORDS EXAMINED, LOCATED AT VARIANCE WITH THOSE REPORTED, OR SHOWN ON RECORDS EXAMINED. THE CONTRACTOR IS REQUIRED TO NOTIFY THE OWNER OF THE UTILITIES OR STRUCTURES CONCERNED PRIOR TO COMMENCING WORK. 52. THE CONTRACTOR SHALL PROVIDE FIRE PROTECTION FOR THE PROJECT UNDER CONSTRUCTION PER REQUIREMENTS OF THE LOCAL GOVERNING AGENCIES. THE CONTRACTOR SHALL PROVIDE AND INSTALL AN AUTOMATIC FIRE SPRINKLER SYSTEM AND ALARM SYSTEM INCLUDING ALL ON SITE FIRE HYDRANTS AND UNDERGROUND MAINS PER REQUIREMENTS OF THE LOCAL GOVERNING AGENCIES AND ANY IDENTIFIED OWNER/TENANT INSURING AGENCIES. SPRINKLER SYSTEM PLANS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. CONTRACTOR SHALL BE RESPONSIBLE FOR APPLICABLE PLAN CHECKS AND PERMITS. ANY CHANGES MADE TO ACCOMMODATE FIELD CONDITIONS SHALL BE RESUBMITTED TO THE CITY AND ARCHITECT AT THE CONTRACTORS EXPENSE. WHERE ENUNCIATOR PANELS, ALARMS, ETC. ARE REQUIRED IN AN EXPOSED LOCATION, CONTRACTOR SHALL SUBMIT PROPOSED LOCATIONS AND CUT SHEETS INDICATING FINISHES AND SIZES TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. 1. THE CONTRACTOR SHALL PROVIDE AND INSTALL FIRE DAMPERS WHERE DUCTS PENETRATE FIRE RATED ASSEMBLIES. 2. PENETRATIONS OF FIRE RESISTIVE WALLS, FLOOR/CEILINGS AND ROOF/CEILINGS SHALL BE PROTECTED AS REQUIRED IN THE CBC CHAPTER 7. A FIRE PENETRATION PROTECTION PLAN FOR EACH APPLICABLE TRADE SHALL BE SUBMITTED BY THE CONTRACTOR TO THE ARCHITECT AND CITY FOR APPROVAL PRIOR TO INSTALLATION IN THE FIELD. PENETRATION PROTECTION SYSTEMS SHALL BE UL LISTED. 3. RETURN AIR PLENUMS SHALL HAVE NO EXPOSED MATERIALS WITHIN THEM WITH A FLAME SPREAD RATING OF 26 OR GREATER OR A SMOKE DEVELOPED RATING OF 50 OR GREATER. ALL WIRING IN RETURN AIR PLENUMS SHALL BE IN NONCOMBUSTIBLE CONDUIT OR SHALL HAVE AN APPROVED PLENUM RATING. TEMPERATURES IN RETURN AIR PLENUMS SHALL BE RESTRICTED TO A RANGE OF 50 TO 125 DEGREES FAHRENHEIT AND MOISTURE CONTENT SHALL BE CONTROLLED SO AS NOT TO ADVERSELY AFFECT GYPSUM PRODUCTS WITHIN THE PLENUM. 4. ALL EXPOSED COMBUSTIBLE FRAMING MEMBERS WITHIN A RETURN AIR PLENUM SHALL BE SHEATHED WITH MIN. ONE LAYER OF 1/2" GYPSUM BOARD SECURELY FASTENED AND TAPED (PROVIDE BLOCKING/FURRING AS REQUIRED) UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. FIRE RETARDANT WOOD AND HEAVY TIMBER MEMBERS MAY BE EXPOSED IN RETURN AIR PLENUMS WHEN SPECIFICALLY APPROVED BY THE BUILDING OFFICIAL. 5. IN SPRINKLERED OCCUPANCIES A3, A4, B, F, M & S, INTERIOR WALL AND CEILING FINISHES SHALL BE OF THE FOLLOWING FLAME SPREAD CLASSIFICATIONS (IN ACCORDANCE WITH CBC 2016 CHAPTER 8): EXIT ENCLOSURES -CLASS B CORRIDORS -CLASS B OTHER AREAS -CLASS C CLASS A ASTM E84 -0-25 FLAME SPREAD: SMOKE DEVELOPED 0-450 CLASS B ASTM E84 -26-75 FLAME SPREAD: SMOKE DEVELOPED 0-450 CLASS C ASTM E84 -76-200 FLAME SPREAD: SMOKE DEVELOPED 0-450 6. CONTRACTOR SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS OF TYPE, QUANTITY AND LOCATION DETERMINED BY THE FIRE DEPARTMENT INSPECTOR. CONTRACTOR SHALL SUBMIT PROPOSED LOCATIONS AND CUT SHEETS INDICATING FINISHES AND SIZES TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. 7. PROVIDE AND INSTALL OUTSIDE GAS SHUT-OFF VALVE AND SIGNAGE IDENTIFYING LOCATIONS OF GAS AND ELECTRICAL SHUT-OFFS PER THE FIRE DEPARTMENT INSPECTOR. 8. PROVIDE AND INSTALL SMOKE DETECTORS, DUCT DETECTORS, AND OTHER SUCH DETECTION DEVICES AS REQUIRED BY CODE AND THE FIRE DEPARTMENT INSPECTOR. 9. PROVIDE ALL PAINTING OF CURBS AND SIGNAGE INDICATING FIRE LANES, ROOF ADDRESS, BUILDING ADDRESS, ETC. AS REQUIRED BY THE FIRE DEPARTMENT INSPECTOR 10. PROVIDE MASTER KEY KNOX-BOX AT ENTRY OF EACH BUILDING AND SITE GATES AS REQUIRED BY THE FIRE DEPARTMENT INSPECTOR. LOCATIONS SHALL BE APPROVED BY THE ARCHITECT PRIOR TO INSTALLATION. 11. IDENTIFICATION OF FIRE AND SMOKE SEPARATION WALLS SHALL BE IDENTIFIED PER CHAPTER 7 OF 2016 CBC. IDENTIFICATION SHALL BE REPEATED AT INTERVALS NOT EXCEEDING 30 FEET MEASURED HORIZONTALLY ALONG THE WALL OR PARTITION; AND INCLUDE LETTERING NOT LESS THAN .5 INCHES IN HEIGHT INCORPORATING THE SUGGESTED WORDING : " FIRE AND OR SMOKE BARRIER -PROTECT ALL OPENINGS," 12. 1. PROVIDE ACCESS DOORS AND PANELS IN WALLS, CEILINGS, AND FLOORS AS REQUIRED BY INSTALLATION OF MECHANICAL, FIRE PROTECTION, ELECTRICAL, AND PLUMBING SYSTEMS IN ADDITION TO THOSE SHOWN ON THE DRAWINGS. CONTRACTOR SHALL SUBMIT PROPOSED LOCATIONS AND CUT SHEETS INDICATING FINISHES AND SIZES TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION 2. CONTRACTOR SHALL VERIFY AND COORDINATE SIZE, LOCATION AND TYPE OF ALL MECHANICAL EQUIPMENT PLATFORMS AND BASES AS WELL AS POWER AND GAS/WATER/DRAIN INSTALLATIONS WITH MANUFACTURERS REQUIREMENTS PRIOR TO INSTALLATION OF EQUIPMENT AND PLATFORMS. CHANGES MADE TO ACCOMMODATE FIELD CONDITIONS OR CONTRACTORS SUBSTITUTIONS SHALL BE MADE AT THE CONTRACTOR'S EXPENSE 3. WHERE RESTROOMS ARE PROVIDED, CONTRACTOR SHALL SUPPLY MECHANICAL VENTILATION TO ENSURE AIR CHANGES EVERY FIVE MINUTES PER CBC CHAPTER 12 CBC 2016 AND TABLE 4.4 OF THE CMC. IN WAREHOUSE AREAS, A MINIMUM OF ONE AIR CHANGE EVERY HOUR SHALL BE PROVIDED VIA VENTILATED SKYLIGHTS OR MECHANICAL SYSTEMS. SEE ROOF PLAN AND MECHANICAL DRAWINGS. 4. 1. THE BOTTOM 10" OF ALL DOORS SHALL HAVE A SMOOTH AND UNINTERRUPTED PANEL FOR OPENING BY WHEELCHAIR FOOTREST. CENTER OF ALL DOOR HARDWARE TO BE 34" MINIMUM TO 44" MAXIMUM ABOVE FLOOR. LATCHING AND LOCKING DOORS TO BE OPERABLE WITH A SINGLE EFFORT BY LEVER OR PUSH-PULL TYPE HARDWARE 2. THE MAXIMUM EFFORT REQUIRED TO OPERATE A DOOR SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS WITH A PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLE TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE RATED DOORS ARE UTILIZED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO 15 POUNDS WITH A CLOSURE DEVICE 3. PROVIDE A 2" WIDE STRIP OF SLIP RESISTANT (EQUAL TO ADJACENT TREADS) MATERIAL IN CONTRASTING COLOR AT 1" FROM THE EDGE OF THE LOWEST TREAD AND AT THE UPPER APPROACH TO EACH RUN OF STAIRS. AT EXTERIOR STAIRS, USE PAINT FOR MARKING TREADS UNLESS NOTED OTHERWISE ON DRAWINGS 4. FAUCET CONTROLS AND OPERATING MECHANISMS FOR DRINKING FOUNTAINS, KITCHEN SINKS, LAVATORIES, AND TOILET FIXTURES SHALL BE OPERABLE WITH ONE HAND NOT REQUIRING GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO OPERATE CONTROLS SHALL NOT EXCEED FIVE POUNDS. THE FLUSH VALVE ON ALL WATER CLOSETS SHALL BE LOCATED ON THE WIDE SIDE OF THE STALL. MAXIMUM HEIGHT OF FLUSH VALVES FOR ACCESSIBLE FIXTURE SHALL NOT EXCEED 44" A.F.F. THE ACCESSIBLE LAVATORIES, FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE NO GREATER THAN 5 LBS. LEVER-OPERATED, PUSH-TYPE, AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. 5. THE MAXIMUM SLOPE OF ANY DISABLED VEHICULAR PARKING STALL SHALL NOT EXCEED 1/4" (1:50) PER FOOT IN ANY DIRECTION. 6. LATCHING & LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL, SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. 7. ALL FLOOR SURFACES IN THE PATH OF TRAVEL SHALL BE SLIP RESISTANT.8. DRINKING FOUNTAIN BUBBLERS SHALL BE ACTIVATED BY A MANUALLY OPERATED SYSTEM COMPLYING WITH SECTION 11B-602 THAT IS FRONT MOUNTED OR SIDE MOUNTED AND LOCATED WITHIN 6" OF THE FRONT EDGE OF THE FOUNTAIN OR AN ELECTRONICALLY CONTROLLED DEVICE. SPOUT OUTLETS SHALL BE 36" MAX. A.F.F. THE SPOUT SHALL BE LOCATED 15" MIN. FROM THE VERTICAL SUPPORT AND 5" MAX. FROM THE FRONT EDGE OF THE UNIT, INCLUDING BUMPERS. THE SPOUT SHALL PROVIDE A FLOW OF WATER AT LEAST 4" HIGH MIN. AND SHALL BE LOCATED 5" MAX. FROM THE FRONT OF THE UNIT. THE ANGLE OF THE WATER STREAM SHALL BE MEASURED HORIZONTALLY RELATIVE TO THE FRONT FACE OF THE UNIT. WHERE SPOUTS ARE LOCATED LESS THAN 3" FROM THE FRONT OF THE UNIT, THE ANGLE OF THE WATER STREAM SHALL BE 15 DEG. MAX. ON AN ACCESSIBLE DRINKING FOUNTAIN WITH A ROUND OR OVAL BOWL, THE SPOUT MUST BE POSITIONED SO THE FLOW OF WATER IS WITHIN 3" OF THE FRONT EDGE OF THE FOUNTAIN 9. OBJECTS PROJECTING FROM WALLS (FOR EXAMPLE TELEPHONES) WITH THEIR LEADING EDGES BETWEEN 27" AND 80" ABOVE FINISH FLOOR SHALL PROTRUDE NO FURTHER THAN 4" INTO WALKS, HALLS, CORRIDORS, PASSAGEWAYS OR AISLES. OBJECTS MOUNTED WITH THEIR LEADING EDGES AT OR BELOW 27"ABOVE THE FINISH FLOOR MAY PROTRUDE ANY AMOUNT INTO WALKS, HALLS, CORRIDORS, PASSAGEWAYS, OR AISLES. FREE STANDING OBJECTS MOUNTED ON POSTS OR PYLONS MAY OVERHANG 12" MAXIMUM FROM 27" TO 80" ABOVE FINISHED FLOOR. PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH OF AN ACCESSIBLE ROUTE OR MANEUVERING SPACE. WALKS , HALLS, CORRIDORS, PASSAGEWAYS AISLES, OR OHER CIRCULATION SPACES SHALL HAVE 80 INCHES ABOVE THE WALKING SURFACE AS MEASURED FROM THE BOTTOM OF THE OBSTRUCTION. ANY OBSTRUCTION OVERHANGING A PEDESTRIAN WAY SHALL BE A MINIMUM OF 80" ABOVE THE WALKING SURFACE AS MEASURE TO THE BOTTOM OF THE OBSTRUCTION. 10. WHERE A GUY SUPPORT IS USED PARALLEL TO A PATH OF TRAVEL, INCLUDING, BUT NOT LIMITED TO SIDEWALKS, A GUY BRACE, SIDEWALK GUY OR SIMILAR DEVICE SHALL BE USED TO PREVENT AN OVERHANGING OBSTRUCTION AS DEFINED. 11. IF A WALK CROSSES OR ADJOINS A VEHICULAR WAY, AND THE WALKING SURFACES ARE NOT SEPARATED BY CURBS, RAILING OR OTHER ELEMENTS BETWEEN THE PEDESTRIAN AREAS AND THE VEHICULAR AREAS, THE BOUNDARY BETWEEN THE AREAS SHALL BE DEFINED BY A CONTINUOUS DETACHABLE WARNING WHICH IS 36" WIDE , COMPLYING WITH SECTION 11B-705. 12. THE HIGHEST OPERABLE PART OF ALL CONTROLS, DISPENSERS, RECEPTACLES AND OTHER OPERABLE EQUIPMENT SHALL BE INSTALLED AT AN ACCESSIBLE LOCATION MEETING THE CLEARANCES AND REACH RANGE REQUIREMENTS OF SECTION 11B-308 & 309 AND NOT LESS THAN 15" ABOVE THE FLOOR OR WORKING PLATFORM. THE CENTER OF 15, 20 & 30 AMP RECEPTACLE OUTLETS SHALL BE NOT LESS THAN 15" ABOVE THE FINISHED FLOOR OR WORKING PLATFORM. 13. THE CENTER OF THE GRIP OF THE OPERATING HANDLE OF CONTROLS OR SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE.OUTLETS, APPLIANCES, OR COOLING , HEATING AND VENTILATING EQUIPMENT SHALL BE 48" ABOVE THE FLOOR OR WORKING PLATFORM. IN CONFORMANCE WITH CBC 11B-308 & 309. 14. THE CENTER OF THE ELECTRICAL RECEPTACLE OUTLETS OR BRANCH CIRCUITS OF 30 AMPERES OR LESS SHALL BE INSTALLED NOT MORE THAN 48 INCHES NOR LESS THAN 14 INCHES ABOVE THE FLOOR OR WORKING PLATFORM. 15. SIGNS: VISUAL CHARACTERS ON SIGNS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER "O" IS 60% MIN. AND 110% MAX. OF THE HEIGHT OF THE UPPERCASE LETTER "I". STROKE THICKNESS OF THE UPPERCASE LETTER "I" SHALL BE 10% MIN. AND 20% MAX. OF THE HEIGHT OF THE CHARACTER. 16. SIGNS: RAISED CHARACTERS AND PICTORIAL SYMBOLS ON SIGNS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER "O" IS 60% MIN. AND 110% MAX. OF THE HEIGHT OF THE UPPERCASE LETTER "I". STROKE THICKNESS OF THE UPPERCASE LETTER "I" SHALL BE 15% MAX. OF THE HEIGHT OF THE CHARACTER. 17. SIGNS: CONTRACTED GRADE II BRAILLE: DOTS SHALL BE 1/10" ON CENTERS IN EACH CELL WITH 2/10" SPACE BETWEEN CELLS, MEASURED FROM THE SECOND COLUMN OF DOTS IN THE FIRST CELL TO THE FIRST COLUMN OF DOTS IN THE SECOND CELL. DOTS SHALL BE RAISED A MINIMUM OF 1/40" ABOVE THE BACKGROUND, AND ARE TO BE ROUNDED, NOT SQUARE DOTS. 18. ALL DOORS SHALL BE FITTED WITH AN ASTRAGAL, SEAL OR BAFFLE AT THE HEAD, JAMB AND SILL1. DOOR JAMBS MOUNTED ON AN EXTERIOR WALL SHALL LAP THE ADJACENT WALL A MINIMUM OF ONE INCH ON BOTH THE INTERIOR AND EXTERIOR SIDE 2. DOORS REQUIRING A VERTICAL TRACK GUIDE SHALL USE A CONTINUOUS MOUNTING ANGLE, SEALED IN ACCORDANCE WITH ITEM 7 BELOW. 3. DOORS MOUNTED BETWEEN JAMBS SHALL HAVE A CONTINUOUS SEAL OR BAFFLE AT EACH JAMB.4. MEETING RAILS OF SECTIONAL DOORS AND MEETING STILES OR RAILS OF BI-PARTING DOORS SHALL BE PROVIDED WITH A SEAL, ASTRAGAL, OR BAFFLE. 5. SWINGING AND REVOLVING DOORS SHALL BE WEATHER STRIPPED AT THE HEAD, SILL AND JAMB.6. OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN WALLS AND FOUNDATIONS, AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS AND FLOORS, AND ALL OTHER OPENINGS BETWEEN CONDITIONED AND UNCONDITIONED SPACES SHALL BE SEALED, CAULKED, GASKETED OR WEATHER STRIPPED TO LIMIT AIR PENETRATION. 7. 8. 9. A "CERTIFICATE OF COMPLIANCE" SIGNED BY THE OWNER AND GENERAL CONTRACTOR SHALL BE GIVEN TO THE BUILDING DEPARTMENT STATING THAT THE WORK HAS BEEN PERFORMED AND MATERIALS INSTALLED ACCORDING TO THE APPROVED PLANS AND SPECIFICATIONS. WITHIN THE SCOPE OF THE ARCHITECTS WORK, THIS PROJECT HAS BEEN DESIGNED TO COMPLY WITH ALL THE APPLICABLE REQUIREMENTS OF THE CALIFORNIA ENERGY COMMISSIONS REGARDING ENERGY CONSERVATION STANDARDS (T-20-1451 TO T-20-1525). THE ARCHITECT SHALL NOT HAVE CONTROL OVER OR CHARGE OF AND SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, SINCE THESE ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY UNDER THE CONTRACT FOR CONSTRUCTION. THE FOLLOWING IS A LIST OF SAFETY ISSUES TO BE REVIEWED BY THE CONTRACTOR PRIOR TO THE START OF THE WORK. THIS LIST IS NOT INTENDED TO BE A COMPLETE LIST OF RELEVANT SAFETY ISSUES. OBSERVATION VISITS PERFORMED BY THE ARCHITECT SHALL NOT INCLUDE REVIEW OF THE FOLLOWING ITEMS: THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE DESIGN ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND HAS NOT BEEN CONSIDERED BY THE ARCHITECT OR HIS CONSULTANTS. THE CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE DURING ALL PHASES OF CONSTRUCTION. 1. CONTRACTOR SHALL DETERMINE ALL PHASES OF WORK WHICH REQUIRE AN ERECTION PLAN ACCORDING TO ALL APPLICABLE SAFETY REGULATIONS. A CERTIFIED COPY OF SUCH ERECTION PLANS SHALL REMAIN ON THE CONSTRUCTION SITE AT ALL TIMES. 2. TEMPORARY LOADING DURING CONSTRUCTION SHALL NOT OVERLOAD DESIGN VALUES. CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING ALL TRADES OF SUCH VALUES PRIOR TO COMMENCEMENT OF WORK. THE CONTRACTOR SHALL PROVIDE MOUNTED VISIBLE SIGNAGE INDICATING THE DESIGN LOADS IN ALL SPACES AS REQUIRED BY APPLICABLE SAFETY REGULATIONS. THE FINAL OCCUPANT OF THE BUILDING SHALL BE RESPONSIBLE FOR NOT EXCEEDING THESE LIMITS FOLLOWING COMPLETION OF THE PROJECT. 3. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE IF A CAL-OSHA PERMIT IS REQUIRED FOR ANY PART OF THE WORK, AND TO OBTAIN SUCH PERMIT SHOULD IT BE REQUIRED. 4. LACK OF A GUARDRAIL AT BUILDING PARAPETS, FLOOR OPENINGS, AND ROOF OPENINGS MAY NOT MEET CURRENT LABOR CODES FOR A SPACE WHICH MAY BE OCCUPIED. THE ARCHITECT RECOMMENDS THE USE OF GUARDRAILS AT ALL SUCH CONDITIONS. SHOULD GUARDRAILS NOT BE INSTALLED, THE OWNER SHALL ACCEPT FULL RESPONSIBILITY. IN ADDITION, THE CONTRACTOR SHALL PROVIDE CLEARLY LEGIBLE SIGNAGE AT THESE LOCATIONS STATING "CAUTION -NO GUARDRAIL." 5. ALL TEMPORARY FLOOR AND ROOF OPENINGS LACKING GUARDRAILS SHOULD BE ADEQUATELY PROTECTED DURING CONSTRUCTION. 6. CONTRACTOR SHALL VERIFY THAT ALL INSTALLED SKYLIGHTS HAVE BEEN DESIGNED TO WITHSTAND THE MINIMUM LOADS AS SPECIFIED IN THE CBC. 7. MATERIALS USED IN THIS DESIGN MAY BE HAZARDOUS TO ONE HEALTH. THE CONTRACTOR AND OWNER SHALL ACCEPT ALL RESPONSIBILITY FOR SUCH MATERIALS AND SHALL POST SIGNAGE WARNING OF SUCH MATERIALS WHERE REQUIRED BY LAW PRIOR TO PROJECT OCCUPANCY. 8. THE CONTRACTOR, DURING CONSTRUCTION, AND THE OWNER, DURING OCCUPANCY, SHALL ASSUME FULL RESPONSIBILITY FOR PROPER ROOF MAINTENANCE TO INSURE PROPER ROOF DRAINAGE AT ALL TIMES. 9. MEANS OF EGRESS SHALL BE ILLUMINATED WITH AT LEAST ONE FOOT CANDLE AT THE FLOOR LEVEL AT ALL TIMES [CBC 1008.2 and 1008.2.1] 53. 13. HAZARDOUS MATERIALS WILL BE STORED AND/OR USED WITHIN THE BUILDING, AS A CONDITION OF OCCUPANCY. SAFETY NOTES: GENERAL NOTES: FIRE PROTECTION NOTES: MECHANICAL & ELECTRICAL NOTES: FIRE DEPARTMENT NOTES 1. INTERIOR FINISHES AND COMBUSTBLE DECORATIVE MATERIALS SHALL COPMLY WITH CFC 801. 2. STORAGE OF COMBUSTBLE MATERIALS IN CLOSELY PACKED PILES OR ON PALLETS, IN RACKS, OR ON SHELVES WHERE THE TOP OF STORAGE IS GREATER THAN 12 FEET IN HEIGHT SHALL COMPLY WITH CFC CHAPTER 23. 3. THE STORAGE, USE AND DISPENSING OF HAZARDOUS MATERIALS SHALL NOT EXCEED THE MAXIMUM ALLOWABLE QUANTITIES AS SET FORTH IN TABLES 307.1(1) AND (2) OF THE CBC. 4. THE STORAGE, USE OR DISPENSING OF HAZARDOUS MATERIALS, AS DEFINED BY THE FIRE CODE, SHALL COMPLY WITH CFC CHAPTER 27. 5. INSTALLATION OR REMOVAL OF ABOVEGROUND/UNDERGROUND STORAGE TANKS AND ASSOCIATED EQUIPMENT SHALL BE APPROVED BY THE ANAHEIM FIRE DEPARTMENT UNDER SEPARATE REVIEW. CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 1/ 2 5 / 2 0 2 4 3: 0 0 : 4 5 P M 1/25/2024 3:00:45 PM T15-1.1 GE N E R A L N O T E S 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - BL D G 2 11 / 1 4 / 2 3 Au t h o r Ch e c k e r CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 1/ 2 5 / 2 0 2 4 3: 0 0 : 4 9 P M 1/25/2024 3:00:49 PM T15-1.2 CA L G R E E N N O T E S 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - BL D G 2 11 / 1 4 / 2 3 Au t h o r Ch e c k e r CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 1/ 2 5 / 2 0 2 4 3: 0 0 : 5 2 P M 1/25/2024 3:00:52 PM T15-1.3 CA L G R E E N N O T E S 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - BL D G 2 11 / 1 4 / 2 3 Au t h o r Ch e c k e r CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 1/ 2 5 / 2 0 2 4 3: 0 0 : 5 6 P M 1/25/2024 3:00:56 PM T15-1.4 CA L G R E E N N O T E S 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - BL D G 2 11 / 1 4 / 2 3 Au t h o r Ch e c k e r EXO G EN ER AT ORAIR C HILL ER WAT ER P UMP S TA TION EXO G EN ER AT ORAIR C HILL ER WAT ER P UMP S TA TION EXO G EN ER AT ORAIR C HILL ER WAT ER P UMP S TA TION EXO G EN ER AT ORAIR C HILL ER WAT ER P UMP S TA TION WAT ER P UMP S TA TION CON T R O L P A N E L CON T R O L P A N E L CON T R O L P A N E L C O N T R O L P A N E L C O N T R O L P A N E L ELECT R I C A L SERVI C E PANEL FURNACE #4 CHARGE END PROPOSED 12X12X24 VACUUMFURNACE #5 CHARGE END FURNACE #3CHARGE END FURNACE #2CHARGE END FURNACE #1CHARGE END HOOD ASSEMBY (TYP) UP 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 A B C D E F G H 1.5 2.6 3.1 7 5.1 5.8 6.5 EX I T EX I T EX I T EX I T EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT MIN. 5' - 0" PATH OF TRAVEL TO REMAIN UNOBSTRUCTED AND CLEAR FROM EQUIPMENT Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 69358 SF (E) 920/930 AIR WAY MIGHTY MOUSE 153 F2 685 100 3 102.75" 2 Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 8669 SF (E) 900 ALLEN 172 F2 75.14 100 2 32" MIN. Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 8697 SF (E) 900 ALLEN FUTURE GROWTH 171 F2 86.67 100 2 32"MIN. Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 25841 SF 912 RUBERTA SWING ARMS 170 F2 264.41 100 2 41.55" Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 3139 SF (E) HERMETICS ROOM 176 F2 31.39 100 1 32"MIN. Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 16435 SF (E) DEBURRING 931 ALLEN 175 F2 164 100 2 24.6" = 32" Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 14457 SF (E) 1021 AIR WAY 169 S2 149.25 100 2 22.38" = 32" MIN. Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 434 SF (E) SAND BLASTING ROOM 168 B "INCIDENTAL USE" 4.39 100 1 32" Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 59547 SF (E) 1007 AIR WAY MICRO D 158 F2 596 100 3 89.4" Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 2012 SF (E) HONEYWELL 165 F1 41 100 1 32" - Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 1377 SF (E) BREAK ROOM 139 A2 'INCIDENTAL USE' 91.8 15 NET 2 13.77 = 32" - Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 854 SF (E) HONEYWELL (2) 166 F1 9 100 1 32" MIN. - Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 2367 SF (E)BREAK ROOM 159 A2 'INCIDENTAL USE' 158 15 2 32"MIN. - Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 1396 SF (E) BREAK ROOM 163 A2 'INCIDENTAL USE' 91.4 15 2 32"MIN. - OV E R A L L W I D T H O F B U I L D I N G 35 0 ' - 0 " F-2/S-2/A2 'INCIDENTAL USE'/B (MODERATE AND LOW HAZARD FACTORY INDUSTRIAL / MODERATE AND LOW HAZARD STORAGE / A2 CAFETERIA 'INCIDENTAL USE' / OFFICE USES) OCCUPANCY CALCULATIONS FOR MANUFACTURING AREA BY THE USE OF NONSEPARATED OCCUPANCY PER 508.3 CBC, USES NEED NOT BE SEPARATED FROM ONE ANOTHER OR FROM THE REMAINDER OF THE BUILDING. THE DOMINATED USE OF F-2 IS USED TO CLASSIFY ENTIRE BUILDING. UNDER THE SECTION 507.4 SPRINKLERED, ONE-STORY BUILDING OF TYPE F AND BEING OPEN ALL SIDES MORE THAN 60'-0", BUILDING IS UNLIMITED IN SIZE. Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 2891 SF ADMIRALL HALL 143 A2 193 15 2 32" MIN. EXIT EXIT Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 2372 SF (E) BREAK ROOM 150 A2 157 15 3 32" MIN. Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 1781 SF (E) PRESS ROOM 196 F1 17.81 100 1 32" MIN. MANUFACTURING Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 5841 SF (E) WET PROCESSING ROOM 195 F1 58.43 100 1 32" FLOOR TO BE SEALED Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 1057 SF (E) SILICONE MOLDING ROOM 198 F2 10.57 100 1 32" Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 1837 SF (E) MASKING ROOM 202 F2 27.81 100 1 32" MIN. ASSEMBLY Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 1827 SF (E) YELLOW CLEAN ROOM 180 F1 22.19 100 1 32"MIN. MANUFACTURING Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 1598 SF (E) MANUAL TRIM ROOM 209 F2 16.02 100 1 32" MIN. ASSEMBLY EXIT Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 2991 SF (E) INVENTORY ROOM 203 S2 7.55 100 1 32" MIN. STORAGE Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 1824 SF (E) WASTE TREATMENT 211 F1 12.19 100 1 32" MIN. FLOOR TO BE SEALED Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 4685 SF (E) SMT LINE ROOM 199 F1 8.28 100 1 32" MIN. MANUFACTURING EXIT EXIT EXIT EXIT Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 10716 SF (E) TERMINII 214 F2 107.10 100 5 2(32") MIN. ASSEMBLY Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 994 SF (E) OPTICAL FLEX 215 F1 9.94 100 2 32" MIN. ASSEMBLY EXIT EXIT EXIT EXIT EXIT Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 1286 SF (E) DRILL ROOM 213 F1 13.94 100 1 32" MIN. MANUFACTURING Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 5082 SF (E) FIBER ROOM 216 F2 50.82 100 2 32" MIN. MAX. TRAVEL DISTANCE TO EXIT 250' PER 1017.2 EQUIP. W/ SPRINKLER: 238.00' TRAVEL DISTANCE TO EXIT Room Number Room name Occupancy Area in SF Occupant Load Factor (OLF) per 1004.1.2 CBC 2019 No. of Occupants No. of Exits Door Exit Width Occupancy Use: 1795 SF THAD ROOM 217 B 12.1 100 2 2.42"=32" MIN. EXIT EXIT CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 1/ 2 5 / 2 0 2 4 3: 0 2 : 0 3 P M 1/25/2024 3:02:03 PM T15-1.5 OC C U P A N C Y A N D E X I T I N G D I A G R A M 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - BL D G 2 11 / 1 4 / 2 3 Au t h o r Ch e c k e r 1" = 40'-0"1 CODE DIAGRAM PHASE XV EXO GENERATORAIR CHILLER WATER PUMP STATION EXO GENERATORAIR CHILLER WATER PUMP STATION EXO GENERATORAIR CHILLER WATER PUMP STATION EXO GENERATORAIR CHILLER WATER PUMP STATION WATER PUMP STATION CONTRO L P A N E L CONT R O L P A N E L CONTRO L P A N E L C O N T R O L P A N E L C O N T R O L P A N E L ELE C T R I C A L SER V I C E PAN E L FURNACE #4 CHARGE END PROPOSED 12X12X24 VACUUMFURNACE #5 CHARGE END FURNACE #3 CHARGE END FURNACE #2 CHARGE END FURNACE #1 CHARGE END HOOD ASSEMBY (TYP) UP 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 A B C D E F G H F.7 1.5 2.6 F.3 F.9 G.5 3.1 7 5.1 5.8 6.5 H.1 PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING ON EACH FLOOR,ALSO DURING CONSTRUCTION CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 1/ 2 5 / 2 0 2 4 3: 0 2 : 1 1 P M 1/25/2024 3:02:11 PM T15-1.6 FI R E E X T I N G U I S H E R P L A N 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - BL D G 2 11 / 1 4 / 2 3 Au t h o r Ch e c k e r 1" = 30'-0"1 FIRE EXT. PHASE XV PLAN KEYNOTES:00 1. NOT USED. 2. EXISTING CURB CUT. 3. EXISTING STREET FIRE HYDRANT 4. EXISTING STREET LIGHT 5. EXISTING ACCESSIBLE PARKING STALL COMPLIANCE SIGNAGE AT DRIVEWAY ENTRANCES INTO SITE. 6. EXISTING FIRE DEPARTMENT CONNECTION. SEE FIRE PROTECTION DRAWINGS. 7. EXISTING FIRE BACKFLOW PREVENTER TO BE SCREENED WITH LANDSCAPE. 8. EXISTING IRRIGATED LANDSCAPING PER GUIDELINES WITH MIN 6" CONCRETE CURBS AT ALL INTERIOR PERIMETERS. 9. EXISTING MEDIUM BROOM FINISH CONCRETE SIDE WALK: MIN. 4.5" THK. 2500 PSI WITH #3 BARS @ 18" O.C. EA. WAY OVER 95% COMPACTED 12" SUBGRADE. PROVIDE CONTROL / CONSTRUCTION JOINTS @ MAX. 5'-0" O.C. SHADED AREAS: #5 TOP-CAST WASH FINISHED CONCRETE WITH THE C-34 DARK GREY COLOR MIX. 10. EXISTING ACCESSIBLE PATH OF TRAVEL FROM STALLS & PUBLIC WAY TO PRIMARY ENTRANCE. SEE CIVIL DRAWINGS. SLOPE NOT TO EXCEED 1:20 EXCEPT AT CURB RAMPS AND OTHER DEFINED RAMPS. CROSS SLOPE NOT TO EXCEED 1/4" PER FOOT. SEE GENERAL NOTES ON THIS SHEET FOR ADDITIONAL DATA. STRIPE PAVING WITH WHITE PAINT AT ALL DRIVEWAY CROSSINGS. 11. EXISTING ACCESSIBLE PRIMARY ENTRANCE / EXIT. PROVIDE 5' MIN. DEEP LEVEL CONCRETE LANDING WITH MAX. CROSS SLOPES NOT EXCEEDING 1/4" PER FOOT. PROVIDE ACCESSIBILITY SIGNAGE, NO SMOKING SIGNAGE, AND EXIT SIGN ON INTERIOR PER SHEET T24-3. 12. EXISTING CONCRETE TILT-UP OFFICE / WAREHOUSE FACILITY. 13. EXISTING ON-SITE FIRE HYDRANT. PROVIDE GUARD POSTS PER FIRE DEPARTMENT STANDARDS. 14. PROPERTY LINE. 15. EXISTING LANDSCAPE CONTROLLER. 16. EXISTING 3000 PSI CONCRETE SITE PAVING OVER COMPACTED SUBGRADE . 17. EXISTING INTERIOR ELECTRICAL SWITCHGEAR. 18. EXISTING TRANSFORMER AND VAULT. 19. UNLESS SHOWN OTHERWISE, ALL EXIT DOORS SHALL HAVE A MINIMUM 5'-0" SQ. CLEAR AND LEVEL CONCRETE LANDING W/ MAX. PER DETAIL 14/AD-1. CROSS SLOPES NOT EXCEEDING 1/4" PER FOOT. TYPICAL U.N.O. WHERE LANDINGS REQUIRE MORE THAN ONE STEP, PROVIDE STEEL HANDRAILS 20. EXISTING GRADE LEVEL LOADING DOOR. 21. EXISTING DOCK HIGH TRUCK LOADING DOOR. 22. EXISTING 8' HIGH ROLLING/SWING GATES AS SHOWN ON SITE PLAN. ALL SITE GATES WILL HAVE KNOX BOXES AND AND RAPID ENTRY SYSTEM TO ALLOW FOR FIRE DEPARTMENT ACCESS. GATES SHALL PROVIDE 80% OPACITY. SUBMIT DETAILED SHOP DRAWINGS AND CALCULATIONS FOR APPROVAL. PROVIDE CONDUIT FOR FUTURE GATE MOTORS AND COMMUNICATIONS. 23. TYPICAL 8" DIA. (U.N.O.) CONCRETE FILLED GUARD POST PAINTED SAFETY YELLOW WHERE SHOWN. 24. EXISTING 12'-0" HIGH MIN. (AS MEASURED FROM INSIDE THE TRUCK YARD) PAINTED CONCRETE SCREEN WALL. PROVIDE WATERPROOFING PER SPECS WHERE LANDSCAPED GRADE ON ONE SIDE OF WALL IS ABOVE FINISH GRADE ON TO OTHER SIDE OF WALL. 25. EXISTING INTERIOR ROOF DRAIN AND/OR OVERFLOW DRAIN TO EXIT BUILDING THROUGH TILT-UP WALL OR RAMP PANEL. DRAIN PIPES TO EXTEND TO FACE OF CURB OR CONNECT WITH ON-SITE STORM DRAIN SYSTEM. SEE CIVIL DRAWINGS. 25. EXISTING INTERIOR ROOF DRAIN AND OVERFLOW DRAIN 26. EXISTING ONE HOUR RATED FIRE PUMP ROOM WITH FIRE DEPARTMENT ACCESS FROM EXTERIOR. PROVIDE SIGNAGE ON EXTERIOR DOOR. 27. EXISTING TYPICAL STANDARD PARKING STALL 9' X 20' (OR 9' X 17' + 3' OVERHANG). 28. EXISTING BOLT DOWN RIBBON WAVE STYLE GALVANIZED BIKE RACK BY PATTERSON WILLIAMS. USE 5 BIKE CAPACITY 1602-05G . 29. EXISTING SANITARY SEWER LINE - 30. EXISTING DOMESTIC WATER LINE - 31. EXISTING TWO COMPARTMENT TRASH ENCLOSURE: MIN. 6' HIGH PAINTED CONCRETE WALLS W/ PAINTED SOLID METAL GATES. PROVIDE 6"H (MIN.) X 6"W CONCRETE CURB AT INTERIOR PERIMETER OF ENCLOSURE WITH EMBEDDED L3” X 3” X 1/4” GALVANIZED STEEL ANGLE & 1/2” ROUND X 6” J-BOLTS @ 4'-0” ON CENTER MAX. PROVIDE CONCRETE SLAB AND APRON PER TRUCKING APRON REQUIREMENTS. ONE COMPARTMENT DESIGNATED FOR RECYCLABLE MATERIALS INCLUDING PLASTICS, METALS, PAPER, GLASS & CARDBOARD. 32. EXISTING 'CV' DESIGNATES A PARKING STALL MARKED AS "CLEAN AIR / VANPOOL / EV" VEHICLE PARKING. 33. EXISTING WATER QUALITY AND DETENTION BASIN . AT BASINS 4 & 5 PROVIDE A 5' MIN. SURROUNDING FENCE WITH MAINTENANCE ACCESS GATES. 34. EXISTING ON SITE LIGHTING - POLE MOUNTED FIXTURES ON SACKED & PATCHED CONCRETE BASE. LIGHTING DESIGNED TO NOT CREATE GLARE INTO ADJACENT PROPERTIES AND STREETS. 35. EXISTING ACCESSIBLE PATH SIGNAGE. 36. EXISTING ELECTRIC VEHICLE CAR CHARGING STATION TO SERVE TWO STALLS. 37. N/A 38. EXISTING 8'-0" TUBULAR STEEL PICKET FENCE. 39. EXISTING 36" MIN. DEPTH TRUNCATED DOME DETECTABLE WARNING SURFACE 40. EXISTING PRIVATE STREET WITH ACCESSIBLE PATH SIDEWALKS & CURB CUTS AND A SIGNALIZED INTERSECTION AT LOWER AZUSA ROAD. 41. EXISTING STORM DRAIN AND EASEMENT. PROTECT IN PLACE. 42. EXISTING CMU SCREEN WALL. PROTECT IN PLACE. 43. EXISTING SEWER PUMP STATION. 44. EXISTING EMERGENCY GENERATOR FOR SEWER PUMP STATION. 45. EXISTING 25' HIGH ILLUMINATED FLAGPOLE 46. EXISTING 12' SQ. CONCRETE PAVED LUNCH PATIO AREA: MIN. 4.5" THK. 2500 PSI WITH #3 BARS @ 18" O.C. EA. WAY OVER 95% COMPACTED 12" SUBGRADE. PROVIDE CONTROL / CONSTRUCTION JOINTS @ MAX. 5'-0" O.C. FINISH: #5 TOP-CAST WASH FINISHED CONCRETE WITH THE C-34 DARK GREY COLOR MIX. 47. NO SMOKING WITHING 15' OF THE BUILDING SIGNAGE. 48. EXISTING AC UNIT PER MECHANICAL 49. EXISTING BREAK ROOMS, RESTROOMS AND MECHANICAL ROOMS 50. EXISTING WORK AREA WITH NEW DEMISING WALLS 51. EXISTING EQUIPMENT CANOPY 52. EXISTING ACCESSIBLE RAMP 53. EXISTING EQUIPMENT PAD. 54. EXISTING 50' FLAG POLE LOCATED ON CONCRETE PILASTER 55. EXISTING LN2 TANK 56. EXISTING EQUIPMENT CANOPY TO BE REMOVED 57. N/A 58. EXISTING STATIONS. 59. EXISTING EQUIPMENT PAD 60. PROPOSED NEW AREA OF WORK (E) PARKING 38 22 38 22 14 38 32 CV CV CV CV CV CV CV CV 5 2 7 8 31 4 47 47 47 18 26 17 45 11 25 46 W 30 S 29 20 21 20 42 41 19 38 22 22 38 27 5 9 108 11 W S 25 2930 23 22 3424 16 13 50 18 4848 4848 48 48 48 4949 39 39 39 39 4949 13 51 52 51 51 51 51 CANOPY 1 CANOPY 3 CANOPY 4 CANOPY 5 CANOPY 6 53 EQ. PAD 1 28 28 54 51 CANOPY 2 EVCS EVCS EVCS EVCS EVCS EVCS EVCS EVCS 58 EVCS EVCS (VAN ACC) 58 59 59 59 59 CV CV CV 60 CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 1/ 2 5 / 2 0 2 4 3: 0 2 : 1 6 P M 1/25/2024 3:02:16 PM A15-1.0 SI T E P L A N 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - BL D G 2 11 / 0 9 / 2 3 Au t h o r Ch e c k e r GENERAL NOTES: 1. SEE CIVIL DRAWINGS FOR ADDITIONAL INFORMATION REGARDING SITE DRAINAGE, TOPOGRAPHY AND UTILITIES. 2. UNLESS NOTED OTHERWISE, SHADED AREAS REPRESENT PROPOSED LANDSCAPE WITHIN PROJECT BOUNDARIES AND ALONG STREET FRONTAGE - SEE LANDSCAPE DRAWINGS FOR ADDITIONAL DATA. PROVIDE PROTECTIVE 6" X 6" (MIN) CONCRETE CURBING FOR ALL PLANTERS ADJACENT TO AREAS INTENDED FOR VEHICLE PARKING OR TRAVELING AND ALL PAVED AREAS. 3. NO EXTERIOR TENANT SIGNAGE IS PROPOSED FOR THE PROJECT AS PART OF THIS PERMIT APPLICATION. 4. FOR PAVING SECTIONS, CONCRETE CURBS, SWALES, AND GUTTERS SEE CIVIL DRAWINGS. NOTES ON THIS DRAWING AND DETAILS ON SHEET AD.1 ARE MINIMUMS ONLY. 5. ALL DIMENSIONS ARE TO FACE OF CONCRETE CURB, FACE OF CONCRETE PANEL, OR TO GRIDLINE U.N.O. 6. PAINT CURBS AND PROVIDE POSTED SIGNAGE TO INDICATE FIRE LANES PER FIRE DEPARTMENT (FIELD INSPECTOR ) REQUIREMENTS. CONTRACTOR TO COORDINATE FINAL LOCATIONS IN FIELD WITH FIRE INSPECTOR. ROLL PRIMER PAINT COAT. 7. ALL AUTO PARKING STALLS SHALL BE STRIPED PER CITY STANDARDS. CONTRACTOR SHALL CONFIRM FINAL STRIPING CONFIGURATION WITH CURRENT CITY STANDARDS PRIOR TO PAINTING. SEE SPECIFIC DETAILS FOR ACCESSIBLE STALL DIMENSIONS. 8. WHEN DIRECTLY IN FRONT OF AUTO STALLS IN OVERHANG AREA, PLANT TREES AND LOCATE LIGHT STANDARDS CENTERED BETWEEN STALLS. 9. PROVIDE ROOT BARRIERS IN LANDSCAPE AREAS WHERE LESS THAN FIVE FEET IN WIDTH U.N.O. ON LANDSCAPE DRAWINGS OR PER CITY STDS. 10. PROVIDE GUARD POSTS AT ALL FIRE HYDRANTS AND P.I.V.'S PER LOCAL ORDINANCES, FIRE PROTECTION DRAWINGS AND PER ARCHITECTURAL DETAILS. 11. PROVIDE A KNOX BOX KEY ACCESS AT THE PRIMARY BUILDING ENTRANCES AND AT ALL SITE GATES TO BE INSTALLED PER FIRE DEPARTMENT RECOMMENDATIONS. (THE NUMBER OF KNOX BOXES REQUIRED FOR EACH BUILDING SHALL BE DETERMINED BY THE FIRE DEPARTMENT PENDING FIELD INSPECTION). ARCHITECT SHALL BE CONSULTED REGARDING LOCATION PRIOR TO INSTALLATION. 12. WALK SURFACES WITH A SLOPE OF LESS THAN 5% GRADIENT SHALL HAVE A MEDIUM BROOM OR EXPOSED AGGREGATE FINISH WITH A SLIP RESISTANCE EQUAL TO A MED. SALT FINISH U.N.O. WALK SURFACES WITH A SLOPE OF GREATER THAN 6% GRADIENT SHALL BE SLIP RESISTANT PER DISABLED ACCESS STANDARDS. ACCESSIBLE WALK CROSS SURFACE SLOPES SHALL NOT EXCEED 1/4" PER FOOT OR 2%. 13. ANY ABRUPT LEVEL CHANGES SHALL BE LESS THAN OR EQUAL TO 1/2" ALONG ANY ACCESSIBLE ROUTE OF TRAVEL. WHEN CHANGES DO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE OF LESS THAN OR EQUAL TO 1:2. LEVEL CHANGES OF 1/4" MAX MAY BE VERTICAL. IF LEVEL CHANGES ARE GREATER THAN 1/2", THEY MUST COMPLY WITH THE REQUIREMENTS OF CURB RAMPS. 14. CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEWING THE SOILS REPORT AND FOLLOWING IT'S RECOMMENDATIONS FOR EXCAVATIONS. 15. ALL UNDERGROUND PIPING SUBJECT TO CORROSIVITY SHALL BE WRAPPED WITH PROTECTIVE COATINGS PER SOILS & CORROSIVITY REPORT RECOMMENDATIONS. 16. PROPERTY LINE MEETS & BOUNDS WHICH MAY BE SHOWN ON THIS DRAWING ARE FOR REFERENCE ONLY. REFER TO CIVIL DRAWINGS. TRUE NORTH PROJECT NORTH 1" = 50'-0"1 PROPOSED SITE PLAN - PHASE XV EXO GENERATORAIR CHILLER WATER PUMP STATION EXO GENERATORAIR CHILLER WATER PUMP STATION EXO GENERATORAIR CHILLER WATER PUMP STATION EXO GENERATORAIR CHILLER WATER PUMP STATION WATER PUMP STATION CONT R O L P A N E L CONTRO L P A N E L CONTR O L P A N E L C O N T R O L P A N E L C O N T R O L P A N E L ELEC T R I C A L SERV I C E PANE L FURNACE #4 CHARGE END PROPOSED 12X12X24 VACUUMFURNACE #5 CHARGE END FURNACE #3 CHARGE END FURNACE #2 CHARGE END FURNACE #1 CHARGE END HOOD ASSEMBY (TYP) UP UP UP 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 A B C D E F G H F.7 1.5 2.6 F.3 F.9 G.5 3.1 7 5.1 5.8 6.5 H.1 5.2 0. 6 0 % (E) ELEC ROOM 101 (E) VESTIBULE 102 (E) PUMP ROOM 103 BREAKROOM 109 2 (E) LOBBY 105 (E) CONFERENCE RM. 107 (E) OPEN OFFICE 108 (E) CLOSET 120 (E) EXECUTIVE OFFICE 119 (E) OFFICE 118 (E) OFFICE 117 (E) OFFICE 116 (E) NETWORK 113 (E) JAN. 112 (E) OFC WOMENS 110 (E) OFC MENS 111 (E) WHRS WOMENS 114 (E) WRHS MENS 115 (E) BREAK ROOM 139 (E) MECHANICAL ROOM 144 (E) MECHANICAL ROOM 152 (E) BREAK ROOM 155 (E) MECHANICAL ROOM 156 (E)BREAK ROOM 159 (E) MECHANICAL ROOM 160 (E) WOMEN'S RESTROOM 162 (E) MEN'S RESTROOM 161 (E) BREAK ROOM 163 (E) MECHANICAL ROOM 164 (E) WOMEN'S RESTROOM 122 (E) MEN'S RESTROOM 121 (E) WOMEN'S RESTROOM 125 (E) MEN'S RESTROOM 124 (E) WOMEN'S RESTROOM 127 (E) MEN'S RESTROOM 126 (E) MECHANICAL ROOM 123 66 ' - 0 " (E) SAND BLASTING ROOM 168 (E) 1007 AIR WAY MICRO D 158 (E) 1021 AIR WAY 169 912 RUBERTA SWING ARMS 170 (E) 900 ALLEN FUTURE GROWTH 171 (E) 900 ALLEN 172 (E) DEBURRING 931 ALLEN 175 (E) HERMETICS ROOM 176 (E) YELLOW CLEAN ROOM 180 (E) HONEYWELL 165 (E) HONEYWELL (2) 166 (E) WOMEN'S RESTROOM 187 (E)MEN'S RESTROOM 186 (E) WOMEN'S RESTROOM 185 (E) MEN'S RESTROOM 184 920' - 0" 8' - 0" (E) 920/930 AIR WAY MIGHTY MOUSE 153 (E) STAIRS TO MEZZANINE (E) CORRIDOR 182 CANOPY 1 CANOPY 3 CANOPY 5 CANOPY 6 (E) SILICONE MOLDING ROOM 198 (E) PRESS ROOM 196 (E) WET PROCESSING ROOM 195 (E) SMT LINE ROOM 199 (E) MASKING ROOM 202 (E) INVENTORY ROOM 203 (E) MANUAL TRIM ROOM 209 1824 SF (E) WASTE TREATMENT 211 (E) DRILL ROOM 213 (E) TERMINII 214 (E) OPTICAL FLEX 215 IF HAZARDOUS MATERIALS WILL BE STORED AND/OR USED WITHIN THE BUILDING, TENANT SHALL BE REQUIRED TO REGISTER WITH THE HAZMAT PROGRAM COORDINATOR IN THE FIRE DEPARMENT PRIOR TO BEING ISSUED THE PERMIT. (E) FIBER ROOM 216 (E) THAD ROOM 217 A15-2.3 1 CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 1/ 2 5 / 2 0 2 4 3: 0 2 : 2 5 P M 1/25/2024 3:02:25 PM A15-2.1 PR O P O S E D F L O O R P L A N 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - BL D G 2 11 / 0 8 / 2 3 Au t h o r Ch e c k e r 1" = 30'-0"1 PROPOSED FLOOR PLAN - PHASE XV GENERAL NOTES: SEE SHEET A15-2.3 FOR KEYNOTES KEYNOTES: SEE SHEET A15-2.3 FOR KEYNOTES 00 TRUE NORTH PROJECT NORTH 1 2 3 4 4 5 5 6 6 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 AA BB CC DD EE FF GG HH 1.5 2.6 3.1 7 7 Room 302 Room 305 912 RUBERTA SWING ARMS 170 (E) 900 ALLEN FUTURE GROWTH 171 (E) DEBURRING 931 ALLEN 175 (E) 1021 AIR WAY 169 (E) 1007 AIR WAY MICRO D 158 (E) 920/930 AIR WAY MIGHTY MOUSE 153 (E) HERMETICS ROOM 176 12' - 0" 14' - 9" (E) INVENTORY ROOM 203 (E) SMT LINE ROOM 199 (E) MASKING ROOM 202 (E) DRILL ROOM 213(E) YELLOW CLEAN ROOM 180 (E) MANUAL TRIM ROOM 209 (E) WASTE TREATMENT 211 (E) WET PROCESSING ROOM 195 (E) WET PROCESSING ROOM 195 (E) PRESS ROOM 196 (E) OPTICAL FLEX 215 (E) TERMINII 214 14' - 9" 14' - 9" 14' - 9"14' - 9" 14' - 9" 14' - 9" 14' - 9" 14' - 9" 14' - 9" 20' - 0" 20' - 0" 20' - 0" A15-2.3 2 16' - 0" CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 1/ 2 5 / 2 0 2 4 3: 0 2 : 3 2 P M 1/25/2024 3:02:32 PM A15-2.2 PR O P O S E D R C P 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - BL D G 2 11 / 0 9 / 2 3 Au t h o r Ch e c k e r GENERAL NOTES: SEE SHEET A15-2.3 FOR KEYNOTES KEYNOTES: SEE SHEET A15-2.3 FOR KEYNOTES 00 TRUE NORTH PROJECT NORTH 1" = 30'-0"1 OVERALL RCP PLAN - PHASE XV PLAN LEGEND: (E) WALLS NEW OR IN-FILL METAL STUD WALL (SEE WALL SCHEDULE) (E) TILT-UP WALL ?WALL TYPE TAG (SEE WALL SCHEDULE) ILLUMINATED EXIT SIGN (E) 2'x4' ACT CEILING 2'x4' T-BAR LAY-IN LED LIGHT FIXTURE SEE ELECTRICAL PLANS EXHUST FAN SEE MECHANICAL PLANS SUPPLY AIR SEE MECHANICAL PLANS RETURN AIR SEE MECHANICAL PLANS (N) 2'x4' ACT CEILING -SEE /1 A15-6.1 1. SEE STRUCTURAL DRAWINGS FOR NOTES AND DETAILS REGARDING SUSPENDING EQUIPMENT AND CEILINGS FROM EXISTING ROOF STRUCTURE. 2. SEE MECHANICAL DRAWINGS FOR FINAL LOCATIONS OF AIR REGISTERS. SEE ELECTRICAL DRAWINGS FOR FINAL LOCATIONS OF LIGHT FIXTURES. 3. SEE SPRINKLER DRAWINGS FOR FINAL LOCATIONS OF SPRINKLER HEADS. 4. ALL RETURN AIR SHALL BE DUCTED. 5. ALL GYP. BD. CEILINGS & SOFFITS SHALL BE P-1 UNLESS NOTED OTHERWISE. 6. T-BAR CEILING PERIMETER "L" METAL MUST BE CAULKED AT ALL EDGES TO THE INTERIOR WALLS. THE COLOR OF THE CAULKING SHALL MATCH THE GRID. 7. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED . INTERNALLY ILLUMINATED EXIT SIGNS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 924 AND SHALL INSTALLED IN ACCORDANCE WITH THE MANUFACTURE'S INSTRUCTIONS AND CHAPTER 27. EXTERNALLY ILLUMINATED EXIT SIGNS SHALL COMPLY WITH GRAPHICS AND POWER SOURCE REQUIREMENTS IN SECTIONS 1011.6.1 AND 1011.6.3 RESPECTIVELY. WHEN THE FACE OF THE EXIT SIGN IS ILLUMINATED FROM AN EXTERNAL SOURCE, IT SHALL HAVE AN INTENSITY OF NOT LESS THAN 5-FOOT CANDLES. 8. THE EMERGENCY POWER SYSTEM SHALL ALSO BE CONNECTED TO AN EMERGENCY ELECTRICAL SYSTEM WHICH IS TO PROVIDE CONTINUED ILLUMINATION FOR A DURATION OF NOT LESS THAN 1-1/2 HR. IN CASE OF PRIMARY POWER LOSS. CONTINUED ILLUMINATION IS TO BE PROVIDED FROM STORAGE BATTERIES, UNIT EQUIPMENT, OR AN ON-SITE GENERATOR AND THE INSTALLATION OF THE EMERGENCY 9. FOR CEILING NOTES & SPEC'S SEE RCP NOTES: /1 A15-6.1 14 D E (E) FFW (E ) F F W 60 ' - 0 " W1 W1 W1 W3 W1 W1 W3 265 266 1' - 10"8' - 0"2' - 0"8' - 0"2' - 0"4' - 0"2' - 8"2' - 6" 2' - 2 " 2' - 8 " 4' - 0 " 2' - 0 " 8' - 0 " 2' - 0 " 8' - 0 " 2' - 0 " 8' - 0 " 2' - 0 " 8' - 0 " 2' - 0 " 8' - 0 " 1' - 2 " (E)(E)(E)(E) (E) (E) (E) (E) 1 A15-3.0 THAD ROOM 217 A15-3.0 2 A15-3.0 3 H H H H (E) FULL HEIGHT (N) 20'-0" HEIGHT (N) 20'-0" HEIGHT (E) FULL HEIGHT 31' - 0" W1 W1 (E) (E) 14 D E 1 A15-3.0 CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 1/ 2 5 / 2 0 2 4 3: 0 2 : 3 4 P M 1/25/2024 3:02:34 PM A15-2.3 EN L A R G E D P L A N S 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - BL D G 2 11 / 0 9 / 2 3 Au t h o r Ch e c k e r GENERAL NOTES: 1. INTERIOR FIRE HOSE AND EXTINGUISHER LOCATIONS SHALL BE PER FIRE PROTECTION DRAWINGS AND AS APPROVED BY FIRE DEPARTMENT. 2. CONTRACTOR SHALL PROVIDE A CHEMICAL HARDENER TO THE FLOOR AND CONTRACTOR SHALL CONFIRM THAT ALL PRODUCTS USED ARE AQMD APPROVED WHERE APPLICABLE. SEE KEYNOTES ABOVE. ALL CONSTRUCTION MARKINGS ON THE FLOOR SLAB MUST BE REMOVED PRIOR TO SPRAYING, INCLUDING GREASE PENCIL, RED CAULK MARKS,TIRE MARKS, ETC. PROVIDE SUBMITTAL SHOWING COMPATIBILITY WITH PROPOSED BOND BREAKER. 3. CONTRACTOR TO PROTECT FLOOR SLAB DURING CONSTRUCTION AND KEEP CLEAN AT ALL TIMES. ALL VEHICLES ON SLAB DURING CONSTRUCTION SHALL BE DIAPERED TO PREVENT OIL SPILLS. 4. ALL DIMENSIONS ARE TO FACE OF CONCRETE WALL, STRUCTURAL GRID LINE, OR CENTERLINE OF STUD/COLUMN U.N.O. 5. ALL DOOR OPENING DIMENSIONS GIVEN ARE FINISH OPENING SIZES. CONTRACTOR SHALL ADJUST OPENING FOR JAMB AND SILL ASSEMBLIES ACCORDINGLY. 6. CONTRACTOR SHALL NOT PLACE CRANES ON THE FLOOR SLAB. CONTRACTOR SHALL SUBMIT THE PANEL LIFTING PLAN TO THE ARCHITECT FOR REVIEW. 7. NO "READY MIX" TRUCKS WILL BE PERMITTED TO DRIVE OR OPERATE ON ANY PORTION OF THE BUILDING FLOOR SLAB. A MAXIMUM OF AN 8 CUBIC YARD "READY MIX" TRUCK MAY BE ALLOWED ON THE FLOOR SLAB FOR PERIMETER CLOSURE STRIP CONCRETE PLACEMENT WITH PRIOR APPROVAL OF THE OWNER. 8. BUILDING IS DESIGNED FOR HIGH PILE STORAGE COMMODITY CLASSES ONE THROUGH HIGH-HAZARD. TENANT'S SHALL SECURE ALL SEPARATE PERMITS THAT ARE REQUIRED FOR ALL STORAGE PLANS, RACK INSTALLATIONS, AND CONVEYOR INSTALLATIONS. 9. FLOOR SLAB MAY SLOPE - SEE CIVIL DRAWINGS. CONTRACTOR SHALL COORDINATE ALL DIMENSIONS TO COMPENSATE FOR SLOPING FLOOR. 10. ALL TRUSS MEMBERS TO BE PAINTED STANDARD GREY. PROVIDE TOUCH-UP PAINT AT ALL FIELD WELDED CONNECTIONS. 11. G-2000 (OR LARGER MACHINE) SOFT CUT CONTROL JOINTS (MUST BE 1-3/4" MINIMUM DEPTH) IMMEDIATELY AFTER FINISH TROWELING. ALL SAWCUT JOINTS ARE TO BE CLEANED OUT AT THE END OF THE PROJECT. 12. ALL FLOOR SLAB PANEL FORM NAIL HOLES TO BE PREDRILLED AND WOOD DOWELED PRIOR TO NAILING. BRACE HOLES TO BE PREDRILLED. METHOD OF CHAMFER LAYOUT IS WITH HIGH STRENGTH SPRAY ADHESIVE OR APPROVED EQUAL. ALL FLOOR SLAB NAIL OR BRACE FRAME HOLES FILLED WITH APPROVED 2 PART EPOXY COMPOUND TO MATCH CONCRETE COLOR. PEGA BOND LV 2000, BURKE EPOXY INJECTION RESIN OR APPROVED EQUAL. 13. ALL PENETRATIONS THROUGH BUILDING ARE TO BE CAULKED ON BOTH THE INTERIOR AND EXTERIOR OF THE WALL. 14. SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF ANY KNOCKOUT WALL PANELS. 15. SACK AND PATCH ALL WALL LIFT POINT POCKETS ON INTERIOR OF WALL PANELS. ALL DIMENSIONS ARE TO FACE OF STUD UNLESS NOTED OTHERWISE 1/4" = 1'-0"1 PROPOSED FLOOR PLAN - PHASE XV - Callout 1 1/4" = 1'-0"2 OVERALL RCP PLAN - PHASE XV - Callout 1 Wall Schedule -PHASE XV Type Mark Description Keynote A EXISTING 10" CONCRETE TILT UP WALL H INTERIOR WALL - 8" 20 GA METAL STUDS @ 16" O.C. U.N.O. WITH 1-LAYER 5/8" TYPE 'X' GYPSUM BOARD ON BOTH SIDES. USE WATERPROOF GYPSUM BOARD IF EXPOSED TO MOISTURE. 14 FINISH FLOOR 0.00' 4' - 0 " 4' - 2 " 3' - 0 " 1' - 0 " 16 ' - 0 " 20 ' - 0 " 8' - 2 " W1 W1 W3 265 1 2 3 4 5 6 7 8 FINISH FLOOR 0.00' 20 ' - 0 " 4' - 2 " 4' - 0 " 265 W3 W1 W1 67 8 D FINISH FLOOR 0.00' 1 A15-3.0 20 ' - 0 " 4' - 0 " 4' - 2 " 266 W3W1W1W1 6 7 8 1. (E) METAL STUD WALL 2. (E) CONCRETE FLOOR SLAB 3. (E) ROOF STRUCTURE 4. (N) HARD LID CEILING (METAL STUDS WITH 1/2" PLYWOOD ON TOP) -SEE STRUCTURAL 5. (N) ACT SUSPENDED CEILING -SEE 6. (N) ALUMINUM WINDOW -SEE WINDOW SCHEDULE 7. (N) DOOR -SEE DOOR SCHEDULE 8. (N) METAL STUD WALL -SEE WALL SCHEDULE CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 1/ 2 5 / 2 0 2 4 3: 0 2 : 3 7 P M 1/25/2024 3:02:37 PM A15-3.0 IN T E R I O R E L E V A T I O N S & S E C T I O N S 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - BL D G 2 11 / 0 9 / 2 3 Au t h o r Ch e c k e r 1/4" = 1'-0"1 SECTION THRU THAD'S ROOM 1/4" = 1'-0"2 Elevation 5 - a 1/4" = 1'-0"3 Elevation 6 - a KEYNOTES:00 DOOR SCHEDULE LEGEND HM HOLLOW METAL FRAMES, PRIMED,18 GAGE. PR PRIMED AND PAINTED WD 1 3/4" SOLID CORE, STAINED GRADE, PLAIN SLICED WHITE BIRCH ST FACTORY FINISHED STAINED # 44813 HD HINGES DOUBLE ACTING 38 " 24" X 30" TEMPERED VISION PANEL.FRAME TO MATCH DOOR JAMB 24" 30 " 43 " M A X . 42 " SEE SCHEDULE SE E S C H E D U L E 8' - 2 " 8' - 0" 4' - 2 " 4' - 0 " T 8' - 2 " 4' - 0" 4' - 2 " 4' - 0 " T CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 1/ 2 5 / 2 0 2 4 3: 0 2 : 4 0 P M 1/25/2024 3:02:40 PM A15-5.0 DO O R A N D W I N D O W S C H E D U L E 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - BL D G 2 11 / 1 4 / 2 3 Au t h o r Ch e c k e r 1.LOCKS SHALL BE KEY OPERATED FROM THE OUTSIDE AND OPERATED FROM THE INSIDE USING A DEVICE NOT PROHIBITED BY CHAPTER 10 OF THE CBC. 2.ALL EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT PER CBC SECTION 1008.1.9. 3.ALL EXTERIOR SWING DOORS SHALL BE EQUIPPED WITH A DEADBOLT AND DEAD LOCKING LATCH . THESE LATCHES SHALL COMPLY WITH CBC SECTION 1008.1.9. 4.AT THE MAIN ENTRANCE ONLY, PROVIDE SIGNAGE STATING IN 1" HIGH LETTER " THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" THE LOCKING DEVICE SHALL BE OF A TYPE READILY DISTINGUISHABLE AS LOCKED. ASSEMBLY SHALL COMPLY WITH CBC SECTION 1008.1.9.3. 5.DEADBOLTS SHALL CONTAIN HARDENED INSERTS OR MANUFACTURER'S EQUIVALENT. STRAIGHT DEADBOLTS SHALL HAVE A MIN. 1" THROW WITH A MIN. 5/8" EMBEDMENT. HOOK OR EXPANDING DEADBOLTS SHALL HAVE A MIN. 3/4" THROW. 6.ALL LOCKS WHICH AUTOMATICALLY ACTIVATE TWO OR MORE DEADBOLTS SHALL EMBED A MIN. 1/2" BUT NEED NOT EXCEED 1/4" INTO A HOLDING DEVICE. 7.PIN-TYPE HINGES ACCESSIBLE TO THE EXTERIOR SHALL HAVE NON-REMOVABLE PINS. 8.ACCESSIBLE MORTISE OR RIM TYPE CYLINDER LOCKS INSTALLED IN HOLLOW METAL DOORS SHALL BE PROTECTED BY CYLINDER GUARDS WHERE THE CYLINDER PROJECTS BEYOND THE EXTERIOR OF THE DOOR. 9.EXITS SHALL BE ILLUMINATED AT ALL TIMES DURING BUILDING OCCUPANCY WITH LIGHT HAVING AN INTENSITY OF NOT LESS THAN 1 FOOT CANDLE AT THE FLOOR PER CBC SECTION 1006. 10.ALL FIRE RATED DOORS AND FRAMES SHALL HAVE COMPLETE EQUALLY RATED ASSEMBLIES INCLUDING SMOKE SEALS, CLOSURES, ETC. FIRE DOOR ASSEMBLIES SHALL BE LABELED BY AN APPROVED AGENCY. 11."T' = TEMPERED SAFETY GLAZING PER CBC SECTION 2406. 12.PROVIDE CLOSURE DEVICES ON ALL EXTERIOR DOORS U.N.O. 13.PROVIDE CLOSURE DEVICES ON ALL EXTERIOR DOORS AND AT PERIMTER OF CONDITIONED SPACES. 14.WIDTH AND HEIGHT OF REQUIRED EXIT DOORS SHALL COMPLY WITH CBC ACCESSIBILITY GUIDELINES. SEE DOOR SCHEDULE FOR ACTUAL SIZES. 15.CENTER OF ALL DOOR HARDWARE TO BE 34" TO 44" ABOVE FLOOR. LATCHING AND LOCKING DOORS TO BE OPERABLE WITH A SINGLE EFFORT BY LEVER OR PUSH-PULL TYPE HARDWARE. 16.THE MAXIMUM EFFORT REQUIRED TO OPERATE A DOOR SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR OR INTERIOR DOORS WITH A PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLE TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE RATED DOORS ARE UTILIZED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO 15 POUNDS WITH A CLOSURE DEVICE. 17.LATCHING & LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL, SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. 18.ALL INTERIOR DOORS SHALL HAVE SILENCERS, UNLESS FULL SEALS ARE REQUIRED. 19.ALL SOLID CORE WOOD DOORS SHALL BE PAINT GRADE OR STAIN GRADE ROTARY SELECT WHITE BIRCH STAINED TO MATCH AS NOTED IN FINISH SCHEDULE. PROVIDE SAMPLE OF DOOR WITH STAINED FINISH FOR APPROVAL. 20.ON ALL VERTICAL LIFT DOORS, BOTTOM OF DOORS SHALL OPEN TO BE MINIMUM 12" HIGHER THAN TOP OF DOOR OPENING IN WALL. 21. LANDINGS OR FLOOR LEVEL AT DOORS SHALL NOT BE MORE THAN 1/2-INCH BELOW THE THERSHOLD. RAISED THERSHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 1/4-INCH AT DOORWAYS SHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL. CBC 11B-404.2.5 DOOR NOTES 1.THE ITEMS LISTED IN THE FOLLOWING "SCHEDULE OF FINISH HARDWARE" SHALL CONFORM THROUGHOUT TO THE REQUIREMENTS OF THE FOREGOING SPECIFICATION. THE LAST COLUMN IN THE HARDWARE SCHEDULE REFERS TO THE MANUFACTURER ABBREVIATION LISTED ABOVE. 2.HARDWARE AT ALL EXIT DOORS SHALL COMPLY WITH CBC SECTION 1008. 3.ON STOREFRONT DOORS, PROVIDE ALTERNATE FOR CONT. GEARED HINGE IN LIEU OF PIVOTS. USE MARKAR FM100 OR PEMKO CFM PEMKOHINGE. 4.ON ALL EXTERIOR DOORS SERVING ELECTRIC ROOMS, COORDINATE WITH LOCAL UTILITY IN ORDER TO PROVIDE A LOCK KEYED TO PUBLIC UTILITIES MASTER KEY. HARDWARE SCHEDULE NOTES:LEGEND OF LISTED MANUFACTURERS: ADA CRL DOR IDC IVES KEE LCN PEM RIX SCH STA TRM VON VON DUPRIN TRIMCO STANLEY SCHLAGE RIXSON PEMKO LCN CLOSERS KEEDEX IVES INTERNATIONAL DOOR CLOSERS DORMA C.R. LAURENCE ADAMS RITE EXTERIOR HARDWARE SETS INTERIOR HARDWARE SET SAFETY TEMPERED GLASS.T W/ KNOCK -DOWN TYPE JAMBS A SOLID CORE INTERIOR DOOR W/ HALF LITE DOOR PROJECT PHASE DOOR FRAME HARDWARE STATUS COMMENTSNO GROUP WIDTH HEIGHT DOOR THICKNESS MATERIAL FINISH MATERIAL FINISH FINISH 265 PHASE 15 A 3' - 0" 8' - 0" 1-3/4" WD ST HM PR PER SCHED NEW 266 PHASE 15 A 3' - 0" 8' - 0" 1-3/4" WD ST HM PR PER SCHED NEW DARK BRONZED ANODIZED ALUM. / GLASS DARK BRONZED ANODIZED ALUM. / GLASS 1/4" = 1'-0"1 W1 1/4" = 1'-0"2 W3 06410 Millwork:Counter Top –Corian, Platinum Cabinet Face -Formica 920-58 Almond Exposed Interior -White melamine Semi-exposed 3mm PVC almond edge-band on doors .5mm PVC almond edge-band on case PB core on cases Medex core on doors Blum 110 degree hinges 100lb Full extension ball bearing drawer slides 4”brushed chrome wire pulls Quicktoe toe-kick at ADA compliant sink cabinet. 07200 Insulation Scrim:White cap sheets “WMP 10”over R30 07550 Roofing:Sarnafil 60Mil S-327, option to upgrade to 80Mil. 08160 Doors & Frames:FRAMES: Welded Hollow Metal Frames, Primed, 18 gage, by Door Components (Strap/Clips for metal Stud framing). DOORS: 1 ¾”Solid Core, Factory Finished Stained #44813, Plain Sliced White Birch Architectural Grade Doors by Pacific Architectural Door Products in Portland Oregon. VISION LIGHTS: VSL24x30 Bronze / Brown Temp Pak ¼”Vision Lite Kit by Air Louvers, set at ADA height. VISION LIGHTS: VSL8x30 Bronze / Brown Temp Pak ¼”Vision Lite Kit by Air Louvers, set at ADA height. (Conference Rooms) LOCKSETS: Schlage L-Series 03A trim in 626 finish (L-9080x03Ax626) LATCHSETS: Schlage PANIC DEVICE: VonDuprin 99L-NLx628 Panic Device HINGES: 4 ½”x 4 ½”BB81x652 Hinges HINGES DOUBLE ACTING: Bommer Hinge 3029x603-6”x 4.5”(Quantity pending door size). DOOR PUSH/PULLS: 4”x16”Push Pull Plate Sets CLOSERES: LCN 4041XP x 689 Door Closer KICK PLATES: 10”x 34”Stainless Steel Kick Plates (Width may vary) STOPS: Trimco 1211x626 Floor Dome Stop HOLD OPENS: Ives FS452-5 x 626 Kick-Down Hold Open STOP & HOLD OPENS: Ives FS40 x 626 Stop and Hold Open GASKETS: Pemco S-88D, 17’Set 08800 Glass & Glazing:Interior windows/storefront: 1 3/4”x 4”dark bronze anodized aluminum from PRL Glass and Aluminum, 1/4”clear tempered glass. Typical RO 8’w. x 4’h. then drywall inside of opening. Exterior windows/storefront: 2”x 4 1/2”dark bronze anodized aluminum from PRL Glass and Aluminum, 1”dual-glazed tempered glass with Graylite II over clear glass. 09110 Drywall:Framing: All Wall 6”18 ga metal studs. Drywall: 5/8”type X each side. Finish: Level 5 no texture. Drywall Ceilings: Metal Stud Ceiling joist (depth by a structural engineer) 16”o.c. with half- inch plywood on top, with R-30 insulation above drywall. 09310 Ceramic Tile:Walls:4”x4”Ceramic Dale Tile, Group 1, White 0100. Wall Grout Color: Laticrete #044 Bright White Non-Sanded Floor Tile: 6”x6”, Color: A1417 Argent clean slate Floor Grout Color: Laticrete #089 Smoke Grey Sanded Cove Base: 6”x12”, Color: A1417 Argent clean slate 09350 Fiberglass Reinforced Panels:Marlite Model No. P-151 Light Grey color. 09510 Acoustic Ceiling/T-Bar:General Areas: 2’x4’x5/8”Square Lay-in Cortega #769A White with Armstrong Prelude 15/16”HD Grid Office: Armstrong: Second Look II with 15/16”HD Grid 09549 Flooring/Carpeting:VCT: Armstrong Standard Excelon No. 51860, Soft Cool Grey Carpet Tile: Shaw Industries Meshweave, # 58501 Midnight Base: Burke/Mercer 4”cove base No. 850 Sterling (on Carpet, VCT and Concrete Floors). 09900 Painting: Ceiling:Frazee –Aquaseal II for Wood Painted wood ceiling:Frazee –FZ487 Swiss Coffee, Speed Sheen Eggshell Interior Walls:Frazee –FZ487 Swiss Coffee, Speed Sheen Eggshell Restrooms:Frazee –FZ487 Swiss Coffee, Acrysheen Semi-Gloss Janitor’s Closet:Frazee –FZ487 Swiss Coffee, Acrysheen Semi-Gloss Door Frames:Vista –Silver Glass, Semi-Gloss Steel Doors: Vista –Silver Glass, Semi-Gloss Exposed Steel:Vista –Silver Glass, Semi-Gloss Handrails/Guardrails:Vista –Silver Glass, Semi-Gloss Exterior metal canopy:Vista –Silver Glass, Semi-Gloss Sprinkler pipes:Frazee –CZ15-25115, Silver Glass, Arothane Semi-Gloss Exterior body color:Frazee –FZ487 Swiss Coffee, Acrikote Exterior green accent:Frazee –Sea Weed, Acrikote Exterior grey color:Frazee –Charcoal Air, Duratec II Wrought iron fence:Frazee –Black, Arothane Semi-Gloss Interior accents:Benjamin Moore –CSP-755 Dusty Miller Duro –8554 M -Rising Smoke Vista –8763 M -Pewter Works 10520 Fire Extinguisher Cabinets:Potter Roemer Alta Series Fire Extinguisher Cabinets Model No. 7012DV, with “Fire Extinguisher”in red vertical lettering; Use #7008DV Semi Recessed FE Cabinet for 5lb Fire Extinguishers. Mount 44”to top of RO. 10800 Toilet Partitions:Lamtec manufacture, floor mounted overhead braced with solid polymer continuous stainless steel brackets. Color:Charcoal Grey with gap fillers above the wainscoting. 10800 Toilet Accessories: Soap dispensers:Owner provided (old Bobrick –B2111) Toilet paper holder:Bobrick –B2740 Paper towel dispensers:Owner provided Feminine napkin disposal:Bobrick –B270 Seat cover dispensers:Bobrick –B221 Waste receptacles:Bobrick –B275 Mirrors:Bobrick –B165 sizes vary 30x36 / 48x36 Grab bars:Bobrick –B5806x48 / 5806x36 Signage:Standard Blue Background and White Lettering GLENAIR TYPICAL FINISH & MATERIAL SCHEDULE 15400 Plumbing Fixtures: Break Room:Sink –Elkay Model #ELUH3118 Faucet –American Standard Model No. 4175.22 Disposal –ISE Badger-5 Hot water dispenser –ISE Model SST –Filter Insta-Hot with F-GN2215 dispenser Janitor Room:Mop Sink –Fiat Model NO. TSB3000 24”x24”with American Standard 8354.112 faucet. Drinking Fountain:Oasis Model No. PG8ACSL Work area Common: Stainless sink:MDL Group 39”Long with Kohler K-8892 Faucets (2) per sink. Restrooms:Lavatory –American Standard Model No. 0356.041 with American Standard 7385.003 Faucet with grid drain. Handicap toilet –American Standard 32854.128 with Sloan 111-1.28 Flush valve, with Olsonite 95 seat. Regular toilet –American Standard 2855.128 with Sloan 111-1.28 Flush valve, with Olsonite 95 seat. Urinal –American Standard 6550.001 with Sloan 186-.5 Flush valve. Water Heater:Bradford white model No. LD50S3-3. 15500 HVAC: Exhaust Fans:Type 1-Cook ACE-D Downblast Centrifugal Exhaust Ventilator- Direct Drive Type 2 -Cook ACE-B Downblast Centrifugal Exhaust Ventilator –Belt Drive Type 3 -Cook ACRU-B / ACRU-HP / ACRU-XP Upblast Centrifugal Exhaust Ventilator –Belt Drive 16000 Electrical: Warehouse/Shop area: 1. Lighting control is designed with acuity brands LC&D panels 2. High bay lighting @ 70-80FC using Lithonia IBE L4830000LMATCMD50K80CRI 3. T-bar fixtures @70-80FC using Lithonia EPANL 2X4 4000LM80CRI50K 4. Power as designed Offices: 1. 2 x 4 LED fixtures 50-60 FC (Oracle 24_OVHP LED DIM 50K) 2. Decora white switches 3. Decora white plugs 4. Watt stopper Occupancy sensors Restrooms: 1. 1 x 4 LED fixtures 50-60 FC (Oracle 40IW4000DIM-27750K) 2. Decora white plugs and GFI 3. Watt stopper Occupancy sensors Exterior wall packs and pole lighting: 1. NLS VUE LED Bronze wall packs (63-250-watt LED) 2. NLS VUE LED Bronze pole lights (90-300-watt LED) Switchgear and Panel boards: 1. Cutler hammer or ITE Siemens 2. MGM Transformers CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 1/ 2 5 / 2 0 2 4 3: 0 2 : 4 3 P M 1/25/2024 3:02:43 PM A15-5.1 FI N I S H S C H E D U L E A N D N O T E S 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - BL D G 2 11 / 0 9 / 2 3 Au t h o r Ch e c k e r FINISH SCHEDULE PHASE XV ROO M Phase NAME FLOOR FINISH WALL FINISH CEILING SYSTEM 217 PHASE 15 THAD ROOM EXPOSED CONCRETE PRIMED AND PAINTED ACT SYSTEM 2019 CBC CHAPTER 8: INTERIOR FINISHES SINGLE DOOR DOUBLE DOOR NOTES: INTERNATIONAL SYMBOL FOR ACCESSIBILITY - BACKGROUND COLOR SHALL BE BLUE 15090 IN FEDERAL STANDARD 595C. SYMBOL, LETTERS AND BRAILLE SHALL BE WHITE. CHARACTERS AND SYMBOLS SHALL HAVE A NON GLARE FINISH AND SHALL BE RAISED 1/32". 5/8" HIGH MIN. SANS SERIF CHARACTERS WITH A WIDTH TO HEIGHT RATIO OF BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH TO HEIGHT RATIO OF BETWEEN 1:5 AND 1:10. GRADE II BRAILLE - 3/8" HIGH CHARACTERS SEE NOTES BELOW 9" 9" ACCESSIBLE ENTRANCE FIN. GRADE 6" 48 " M I N . 60 " M A X . 6" 1. PROVIDE 6" SQ. ACCESSIBILITY SYMBOL AT ALL PRIMARY BUILDING ENTRANCES PER CBC CHAPTER 11B DIVISION 2 SECTIONS 11B-201.1 &11B-202.4 2. THE SIGN SHALL COMPLY WITH CBC CHAPTER 11B DIVISION 7 SECTIONS 11B-703.2 THRU 703.7.2 AND CBC SECTION 1011. 3. THE SIGN SHALL BE LOCATED ADJACENT TO THE LATCH SIDE OF A SINGLE DOOR AND RIGHT SIDE OF DOUBLE DOORS 48" MIN. A.F.F. TO THE BOTTOM OF LOWEST BRAILLE CHARACTER AND 60" MAX. TO THE BASELINE OF THE HIGHEST LINE OF RAISED CHARACTER. SIGN SHALL BE CENTERED IN AN 18" X 18" CLEAR AREA ADJACENT AND CLEAR OF THE DOOR SWING PER SECTION 11B-703.4.2. 4. VISUAL CHARACTERS ON SIGNS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER "O" IS 60% MIN. AND 110% MAX. OF THE HEIGHT OF THE UPPERCASE LETTER "I". STROKE THICKNES OF THE UPPERCASE LETTER "I" SHALL BE 10% MIN. AND 20% MAX. OF THE HEIGHT OF THE CHARACTER. 5. CONTRACTED GRADE II BRAILLE: DOTS SHALL BE 1/10" ON CENTERS IN EACH CELL WITH 2/10" SPACE BETWEEN CELLS, MEASURED FROM THE SECOND COLUMN OF DOTS IN THE FIRST CELL TO THE FIRST COLUMN OF DOTS IN THE SECOND CELL. DOTS SHALL BE RAISED A MINIMUM OF 1/40" ABOVE THE BACKGROUND, AND ARE TO BE ROUNDED, NOT SQUARE DOTS. GRADE II BRAILLE - SEE NOTE #5 BELOW FOR ADD'L REQUIREMENTS SINGLE DOOR SIGN LOCATION DOUBLE DOOR SIGN LOCATION EXIT EXITSTAIR DOWN RAMP DOWN SIGN TYPE D NOTES: 1. PROVIDE WALL MOUNTED EXIT SIGNAGE AT EACH DOOR REQUIRED TO HAVE AN EXIT SIGN PER 2013 CBC SECTION 1011. 2. THE SIGN SHALL COMPLY WITH CBC SECTIONS CHAPTER 11B SECTIONS 11B-703.1, 11B-703.3 AND 11B703.5 DIVISION 7. AND 1011 CBC. 3. THE SIGN SHALL BE LOCATED ADJACENT TO THE LATCH SIDE OF A SINGLE DOOR AND RIGHT SIDE OF DOUBLE DOORS 48" MIN. A.F.F. TO BOTTOM OF LOWEST BRAILLE CHARACTER AND 60" MAX. TO TOP OF HIGHEST BRAILLE CHARACTER. A PERSON SHALL BE ABLE TO APPROACH WITHIN 3" OF THE SIGN WITHOUT ENCOUNTERING A PROTRUDING OBJECT OR BE WITHIN THE SWING OF THE DOOR PER CBC SECTION 11B-703.4.2. 4. VISUAL CHARACTERS ON SIGNS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER "O" IS 60% MIN. AND 110% MAX. OF THE HEIGHT OF THE UPPERCASE LETTER "I". STROKE THICKNESS OF THE UPPERCASE LETTER "I" SHALL BE 10% MIN. AND 20% MAX. OF THE HEIGHT OF THE CHARACTER. 5. CONTRACTED GRADE II BRAILLE: DOTS SHALL BE 1/10" ON CENTERS IN EACH CELL WITH 2/10" SPACE BETWEEN CELLS, MEASURED FROM THE SECOND COLUMN OF DOTS IN THE FIRST CELL TO THE FIRST COLUMN OF DOTS IN THE SECOND CELL. DOTS SHALL BE RAISED A MINIMUM OF 1/40" ABOVE THE BACKGROUND, AND ARE TO BE ROUNDED, NOT SQUARE DOTS. WALL MOUNTED SIGN - BACKGROUND COLOR SHALL BE BLUE 15090 IN FEDERAL STANDARD 595C. LETTERS AND BRAILLE SHALL BE WHITE. CHARACTERS SHALL HAVE A NON GLARE FINISH AND SHALL BE RAISED 1/32". 1" HIGH MIN. SANS SERIF CHARACTERS - SEE NOTE #3 BELOW FOR ADD'L REQUIREMENTS. GRADE LEVEL EXITS SHALL HAVE THE WORD "EXIT". EXIT DOORS THAT LEAD DIRECTLY TO A STAIR OR RAMP SHALL HAVE THE FOLLOWING WORDS AS APPROPRIATE: "EXIT STAIR DOWN" "EXIT RAMP DOWN" "EXIT STAIR UP" "EXIT RAMP UP" FIN. FLR. EXIT STAIR DOWN EXITSTAIR DOWN SIGN TYPE C AS REQUIRED EXIT STAIR DOWN EXIT SIGN TYPE EXIT ROUTE SIGN TYPE B A 48 " M I N . 60 " M A X . 3" M I N . 5/8" TYPE 'X' GYP. BRD. ON BOTH SIDES ALUM. FRAME WINDOW. REFER TO SCHEDULE 6" METAL STUDS HEADER CORNER BEAD 4 7/8" METAL STUDS @ 16" O.C. 5/8" THK. GYP. BOARD EACH SIDE METAL STUD HEADER WESTERN INTEGRATED CLEAR ANODIZED ALUMINUM FRAMES W/14GA. HINGE REINFORCING PLATES OR EQUAL. FACE OF DOOR STANDARD THRESHOLD SET IN MASTIC 1:2 MAX. SLOPE INTERIOR INTERIOR 1 3 / 4 " 1/2 " 1" A T H E A D 5/8 " A T J A M B 5" 2" DOOR 1/2 " M A X . 1/4 " M A X . FINISH FLOOR CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 1/ 2 5 / 2 0 2 4 3: 0 2 : 4 4 P M 1/25/2024 3:02:44 PM A15-6.0 DE T A I L S 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - BL D G 2 11 / 1 4 / 2 3 Au t h o r Ch e c k e r 3" = 1'-0"1 INTERIOR WINDOW DETAIL 3" = 1'-0"2 DOOR HEADER AND SILL 3" = 1'-0"3 PRIMARY ENTRANCE SIGNAGE 12" = 1'-0"4 TACTILE EXIT SIGNS 1 1/2"MIN.EMBED 1/2" 8" MAX. CHANNEL SPACERS MAY BE SLOTTED ANGLES OR CHANNELS W/ DIAMOND POINTS OF SPRING STEEL WHICH SNAP TIGHT TO PREVENT MOVEMENT OF STRUT 5/8" TYPE 'X' GYP. BD. SLOTTED ANGLE SPACER W/ HORIZONTAL 6d RINGSHANK NAIL (SEE NOTE 2) ALTERNATE LOCATION W/ OUT NAIL. NOTCHING PERMITTED ONLY AT RUNNER. MAIN OR CROSS RUNNER POP RIVET PER MANUF. SPEC'S @ 2 SIDES ONLY STANDARD LEDGER ANGLE WALL CONNECTION ANCHOR TO STRUCTURAL ELEMENT 12 GA. HANGER WIRE TYP. (SEE NOTE 1) MIN . 3 T I G H T TU R N S I N 1 1 / 2 " NOTES: 1.) 1/4 OF THE LENGTH OF THE END RUNNER WHICHEVER IS LESS. 2.) NAILS AT ENDS OF HORIZONTAL STRUTS ARE TO BE PLACED WITH NAIL HEAD TOWARD CENTER LINE OF SPAN OF STRUT. .75-IN. 2" MIN.SUSPENDED CEILING TYP. METAL STUD CEILING JOISTS CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 1/ 2 5 / 2 0 2 4 3: 0 2 : 4 6 P M 1/25/2024 3:02:46 PM A15-6.1 CE I L I N G D E T A I L S 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - BL D G 2 11 / 0 9 / 2 3 Au t h o r Ch e c k e r SUSPENDED CEILING: SUSPENDED ACOUSTICAL CEILING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF ASTM C 635, ASTM C 636 AND ASTM E 580 SECTION 5. [SEC 1613.1 CBC]. PER ASCE 7-16, SEC 13.5.6.2.2: 1.HEAVY DUTY T-BAR GRID SYSTEM SHALL BE USED. 2. THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LOESS THAN 2-IN. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE OF THE CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL DIRECTION SHALL HAVE A 0.75-IN. CLEARANCE FROM THE WALL AND SHALL REST UPON A BE FREE TO SLIDE ON A CLOSURE ANGLE. SEE DETAIL ABOVE AND BELOW FOR ADDITIONAL DIAGRAMS. 3.FOR CEILING AREAS EXCEEDING 2,500 S.F., A SEISMIC SEPARATION JOINT OR FULL HEIGHT PARTIOIN THAT BREAKS THE CEILING UP INTO AREAS NOT EXCEEDING 2,500 S.F. SHALL BE PROVIDED UNLESS STRUCTURAL ANALYSES ARE PERFORMED OF THE CEILING BRACING SYSTEM FOR THE PRESCRIBED SEISMIC FORCES THAT DEMONTRATE CEILING SYSTEM PENETRATIONS AND CLOSURE ANGLES PROVIDE SUFFICIENT CLEARANCE TO ACCOMMODATE THE ANTICIPATED LATERL DISPLACEMENT. EACH AREA SHALL BE PROVIDED WITH CLOSURE ANGLE. 4.EXCEPT WHERE RIDID BRACES ARE USED TO LIMIT LATERAL DEFLECTIONS, SPRINKLER HEADS AND OTHER PENETRATIONS, SHOW A 2" OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY, A SWING JOINT THAT CAN ACCOMMODATE 1" CEILING MOVEMENT IN A HORIZONTAL DIRECTIONS IS PERMITTED TO BE PROVIDED AT THE TOP OF THE SPINKLER HEAD EXTENSION. 5. LATERAL BRACING FOR SUSPENDED CEILING SHALL BE PROVIDED. WHERE CEILING IS NOT SUPPORTING INTERIOR PARTITIONS, CEILING BRACING SHALL BE PROVIDED BY FOUR NO. 12 GAUGE WIRES SECURED TO THE MAIN RUNNER WITHIN 2 INCHES OF THE CROSS RUNNER INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. A STRUT (ADEQUATE TO THE RESIST THE VERTICAL COMPONENT FROM LATERAL LOADS) FASTENED TO THE MAIN RUNNER SHALL BE EXTENDED TO A AND FASTENED TO THE STRUCTURAL MEMBERS OF THE ROOF OR FLOOR ABOVE. THESE HORIZONTAL RESTRAINT POINTS SHALL BE PLACED 12 FEET O.C. IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6 FEET OF EACH WALL. ATTACHMENT OF RESTRAINT WIRES TO THE STRUCTURE ABOVE SHALL BE ADEQUATE FOR THE LOAD IMPOSED. 3" = 1'-0"1 TYP. DROP CEILING CONNECTION AND NOTES E (N) 8"x20 GAGE STUDS @ 16"o.c. 10"x18 GAGE CEILING JOISTS @ 12"o.c. 14 7S15-2.0 12S15-2.0 (E) 8"x18 GAGE STEEL STUDS @ 16"o.c. 9S15-2.0 7S15-2.08S15-2.0 10S15-2.0 NOTES: 1. 2. FOR OPENINGS IN WALLS, SEE . INDICATES DIRECTION OF CEILING JOIST SPAN. 5BS15-2.0 (E) 8"x18 GAGESTUDS @ 16"o.c. (N) 8"x20 GAGE STUDS @ 16"o.c. 251/4" = 1'-0" JF A GENERAL NOTES 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - B L D G 2 DM #2 3 1 5 3 AS S O C I A T E S , I N C . GR O S S M A N & S P E E R DR A W I N G N A M E : 2 3 1 5 3 S 1 5 - 1 . 0 . D W G 11/14/2023 PARTIAL FLOOR PLAN - THAD ROOM S15-1.0 ALL WORKMANSHIP, MATERIAL, AND TESTING SHALL CONFORM TO THE REQUIREMENTS OF THE 2022 CALIFORNIA BUILDING CODE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS, TO VERIFYCONDITIONS AT THE JOB SITE AND TO CROSSCHECK DETAILS AND DIMENSIONS ON THE STRUCTURAL DRAWINGS WITH RELATED REQUIREMENTS ON ALL OTHER PERTINENTDRAWINGS BEFORE PROCEEDING WITH CONSTRUCTION. ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFOREPROCEEDING WITH CONSTRUCTION. DETAILS MARKED TYPICAL SHALL APPLY IN ALL CASES, UNLESS SPECIFICALLY DETAILED OTHERWISE. WHERE NO DETAIL IS SHOWN, CONSTRUCTION SHALL BE AS SHOWN FOROTHER SIMILAR WORK. THE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, AND SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS,TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING BRACING, SHORING, AND LAYDOWN OF CONSTRUCTION MATERIALS, ETC. UNLESS SPECIFICALLY INDICATEDOTHERWISE, THE DESIGN AND INSTALLATION OF TEMPORARY SHORING AND BRACING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. UNLESS OTHERWISE STATED IN WRITING, SITE VISITS BY REPRESENTATIVES OF THESTRUCTURAL ENGINEER: A. DO NOT INCLUDE INSPECTION OF PROTECTIVE OR TEMPORARY CONSTRUCTION.B. ARE GENERAL IN NATURE AND ARE NOT CONTINUOUS OR DETAILED. C. DO NOT GUARANTEE CONTRACTOR'S PERFORMANCE.D SHALL NOT BE CONSTRUED AS SUPERVISION OF CONSTRUCTION. DIMENSIONS SHALL GOVERN OVER SCALES SHOWN ON DRAWINGS. 1. 2. 3. 4. 5. 6. 7. GENERAL RISK CATEGORY = II IMPORTANCE FACTOR I = 1.0 MAPPED ACCELERATION PARAMETERS:SS = 1.742 S1 = 0.641 SITE CLASS = D - DEFAULT DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS:SDS = 1.394 SD1 = 0.726 SEISMIC DESIGN CATEGORY =D 1. 2. 3. 4. 5. 6. SEISMIC DESIGN DATA STEEL STUDS SHALL BE IN ACCORDANCE WITH THE STEEL STUD MANUFACTURERSASSOCIATION (SSMA) SPECIFICATIONS AND ICC ESR-3064P, CONFORMING TO ASTM A653SSOR A1011SS, MINIMUM YIELD = 33.0 KSI U.N.O., AND GALVANIZED CONFORMING TO ASTMA525, G90, HAVING THE MINIMUM VALUES IN ACCORDANCE WITH THE CHART BELOW. REFER TO ARCHITECTURAL DRAWINGS FOR INTERIOR STUD SIZES, OTHER THAN THOSEINDICATED. STUD TRACKS SHALL BE SAME GAGE AS STUDS WITH 112" FLANGES, U.N.O. STUD TO TRACK CONNECTION SHALL BE 1-#8 SCREW AT EACH FLANGE U.N.O. SCREW MUST PENETRATE STUDS BY AT LEAST 3 THREADS. SIZE DESIGNATION GAGE AREA (IN )2 Ix (IN )4 Sx (IN )3 REMARKS 10"1000S162-43 0.627 7.523 1.30218 8"800S162-33 0.413 3.384 0.71020 1. 2. 3. 4. 5. COLD-FORMED METAL FRAMING ALL EXPANSION ANCHORS SHALL BE CARBON STEEL HILTI KWIK BOLT TZ (ICC ESR-1917),CONCRETE ANCHORS. ANCHORS SHALL BE INSTALLED AT EMBEDMENT DEPTHS AND TESTEDAS SHOWN IN THE TABLE BELOW, UNLESS DETAILED OTHERWISE. THE TENSION AND SHEAR VALUES ARE FOR ANCHORS INSTALLED IN HARD ROCK OR LIGHTWEIGHT CONCRETE WITH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT THE TIMEOF INSTALLATION. ALLOWABLE LOADS IN TABLE ARE BASED ON MINIMUM EDGE DISTANCE AS TABULATED ONONE SIDE AND CRACKED CONCRETE PER ICC ESR-1917. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ICC ESR-1917. COMPLY WITH ALL MANUFACTURER'S RECOMMENDATIONS. CONTINUOUS INSPECTION IS REQUIRED FOR ANCHOR INSTALLATION. VALUES IN TABLE ARE BASED ON ALLOWABLE STRESS DESIGN AND EARTHQUAKE LOADING. THICKNESS OF CONCRETE MUST BE AT LEAST 1.5x BOLT EMBEDMENT AS TABULATED. USE STAINLESS STEEL ANCHORS AT EXPOSED AREAS. 1. 2. 3. 4. 5. 6. 7. 8. 9. ANCHORDIAMETER(IN) DRILL BITDIAMETER(IN) EMBEDMENT (IN) ICC ESR TENSION VALUE(#) HARDROCK (LT.WT.) ICC ESRSHEAR VALUE (#)HARDROCK (LT.WT.) INSTALLATIONTORQUE(FT.-#) MINIMUMEDGE DISTANCE 3 4 5 6 866 (520) 1875 (1125) 2594 (1556) 3356 (2014) 1047 (790) 2365 (1419) 3529 (2211) 5294 (3177)110 60 40 25 6" 6" 7.5" 9" 38 12 58 34 38 12 58 34 EXPANSION ANCHORS IN CONCRETE HILTI LOW-VELOCITY POWER-DRIVEN FASTENERS (SHOTPINS) MAY BE USED TO ATTACHLIGHT GAGE COLD-FORMED STEEL FRAMING TO CONCRETE AND STEEL BASE MATERIALS INACCORDANCE WITH ESR-2269. SHOTPINS SHALL NOT BE USED IN CONCRETE CURBS. THE ALLOWABLE LOADS SHALL BE 100 POUNDS OR 80% OF ICC APPROVAL VALUES,WHICHEVER IS LESS. QUALIFICATION FOR USE OF ALL POWER ACTUATED TOOLS MUST MEET ANSI A10.3STANDARD AS REQUIRED BY THE MANUFACTURER AND ALL OSHA REQUIREMENTS. 1. 2. 3. 4. POWER DRIVEN FASTENERS (SHOTPINS) GE N E R A L N O T E S PA R T I A L F L O O R P L A N - T H A D R O O M 1 1 1 NOTES: PROVIDE STRAPS EACH FACE OF WALL.1. STUDS TYP.SILL TYP. HEADER TYP. PROVIDE DRYWALL EDGE SCREWS TO EACH STRAP BETWEEN OPENINGS SIMPSON CS22 WITH 2-#8 SCREWS EACH END TO HEADEROR SILL JAMB STUDS TYP. OPENING TYP. 8"x20 GAGE STUDS @16"o.c. 12" PLYWOOD WITH #10SCREWS @ 6"o.c. EDGESAND 12"o.c. FIELD (3) -#10 SCREWSEACH BLOCK TYP. 10"x18 GAGE CEILING JOIST WITH (3) -#10 SCREWS EACH STUD 10"x18 GAGE CEILING JOISTS @ 12"o.c. EDGE SCREW 2 BAYS 10"x18 GAGE BLOCKING @ 24"o.c. 20'-0" A C D E F SECTION ELEVATION NOTES:INSTALL BRIDGING @ 48"o.c. WHERE WALL FINISHDOES NOT OCCUR OR IS DISCONTINUOUS ON ONEOR BOTH SIDES OF WALL. BUCKLEBRIDGE BLOCKING AT 48"o.c. MAY BE USED FOR 6" STUD WALLS IN LIEU OF BRIDGINGSPECIFIED IN NOTE 1. 1. 2. 112"x16 GAGE COLD-ROLLEDCHANNEL BRIDGING THRU PRE-ALIGNED STUDPUNCHOUTS L112"x112"x16 GAGEx (STUD DEPTH - 12") WITH 2-#10 SCREWS @ EACH STUD 2-#10 SCREWS EACH ANGLE 2-#10 SCREWS @ 12"o.c. DOUBLE STUDSAND TRACK L2x2x14 GAGE x STUD SIZE MINUS 12" WITH2-#10 SCREWS EACH LEG TRACK TYP. NOTES:TYPICAL BACKING FOR ANY ARCHITECTURAL ITEMATTACHED TO WALL.1. STEEL STUDS TYP. 6"x14 GAGE TRACK WITH 112"FLANGES CUT AND BENT AT STUDS AS SHOWN 4-#10 SCREWS EACH STUD TYP. SCREWS 80% ICCALLOW. TENSION 80% ICCALLOW. SHEAR 4-#10 438# 1184# STEEL STUDSTYP. #10 SCREW @ 24"o.c. TYP. STEEL STUDS TYP. #10 SCREW @ 24"o.c. TYP. NOTES:WHERE OPENINGS ARE SPACED 4'-0" OR LESS FROMEACH OTHER, PROVIDE STRAPPING PER .1. B #10 SCREW @ 16"o.c. TYP. 6 PLACES AS SHOWN CONT. STEEL STUDS SAMESIZE AS WALL STUDS, COPE FLANGES AT ENDS AND LAP WEBS WITH JAMB STUDS AND FASTEN WITH 2-#10 SCREWS EACH STUD. FOR 13'-6" OPENING, USE 8" x 16GA. (50 KSI) STUDSAND TRACKS CONCRETE SLAB 38"DIA. HILTI KWIK HUS-EZ WITH 212" EMBEDMENT(ICC ESR 3027) 6" B1 B1 DOUBLE STUDS AT 8'-0" WINDOWS TRIPLE STUDS AT OPENINGS GREATER THAN 8'-0"CONT. TRACK L2x2x14 GAGE x STUD SIZE MINUS 12" WITH 2-#10SCREWS EACH LEG TRACK AT NESTED STUD #10 SCREW EACH LEG @ 12"o.c. #10 SCREW @ 12"o.c. TRIPLE JAMB STUD WHERE OCCURS S15-2.011 (E) 8"x18GAGE STUDS @ 16"o.c. 12" PLYWOOD WITH #10SCREWS @ 6"o.c. EDGES AND 12"o.c. FIELD (3) -#10 SCREWS EACH BLOCK TYP. 10"x18 GAGE CEILING JOIST WITH (3) -#10 SCREWS EACH STUD 10"x18 GAGE CEILING JOISTS @ 12"o.c. EDGE SCREW 2 BAYS 10"x18 GAGE BLOCKING @ 24"o.c.(E) 8"x18 GAGESTUDS @ 16"o.c. 12" PLYWOOD WITH #10SCREWS @ 6"o.c. EDGES AND 12"o.c. FIELD 2"x2"x14 GA. x0'-8"STEEL ANGLE EACHJOIST WITH (3) -#10 SCREW EACH LEG 10"x18 GAGE CONT. TRACK WITH (3) -#10 SCREWS EACH STUD 10"x18 GAGE CEILING JOISTS @ 12"o.c. 20'-0" 8"x20 GAGESTUDS @ 16"o.c. 12" PLYWOOD WITH #10SCREWS @ 6"o.c. EDGES AND 12"o.c. FIELD 2"x2"x14 GA. x0'-8"STEEL ANGLE EACHJOIST WITH (3) -#10 SCREW EACH LEG 10"x18 GAGE CONT. TRACK WITH (3) -#10 SCREWS EACH STUD 10"x18 GAGE CEILING JOISTS @ 12"o.c. 8x20 GAGE STUDS @ 16"o.c. TRACK CONT. WITH HILTI X-U SHOTPINS @ 16"o.c. (1" EMBEDMENT) (E) SLAB ON GRADE NOTES: WHERE TRACK IS SPLICED PROVIDE A SHOTPIN WITHIN 6" OF END OF EACH TRACK. 1. 25 S15-2.0 DE T A I L S A N D S E C T I O N S XX5 7SECTION 8SECTION 10 15 17 20 21 24 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1259.00 GL E N A I R L O G I S T I C S - B L D G 2 DM #2 3 1 5 3 AS S O C I A T E S , I N C . GR O S S M A N & S P E E R DR A W I N G N A M E : 2 3 1 5 3 S 1 5 - 2 . 0 . D W G 11/14/2023 SECTION SECTION9 18 19 22 23 TYPICAL INTERIOR STEEL STUDS 11SECTION SECTION 13 1412 16 GENERAL NOTES DIVISION OF WORK SCOPE OF WORK 1 2 3 4 4 5 5 6 6 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 AA BB CC DD EE FF GG HH 1.5 2.6 3.1 7 7 Room 302 Room 305 912 RUBERTASWING ARMS 170 (E) 900 ALLENFUTURE GROWTH 171 (E) DEBURRING931 ALLEN 175 (E) 1021 AIR WAY 169 (E) 1007 AIR WAYMICRO D 158 (E) 920/930 AIRWAY MIGHTYMOUSE 153 (E) HERMETICSROOM 176 12' - 0" 14' - 9" (E) INVENTORYROOM 203 (E) SMT LINEROOM 199 (E) MASKINGROOM 202 (E) DRILL ROOM 213(E) YELLOWCLEAN ROOM 180 (E) MANUAL TRIMROOM 209 (E) WASTETREATMENT 211 (E) WETPROCESSINGROOM 195 (E) WETPROCESSINGROOM 195 (E) PRESS ROOM 196 (E) OPTICAL FLEX 215 (E) TERMINII 214 14' - 9" 14' - 9" 14' - 9"14' - 9" 14' - 9" 14' - 9" 14' - 9" 14' - 9" 14' - 9" 20' - 0" 20' - 0" 20' - 0" CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . By Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 GL E N A I R L O G I S T I C S - B L D G 2 Au t h o r Ch e c k e r M15-1.0 MECHANICAL COVER SHEET - P H A S E X V AREA OF WORK 14 E CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . By Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 GL E N A I R L O G I S T I C S - B L D G 2 Au t h o r Ch e c k e r M15-2.0 PA R T I A L H V A C F L O O R P L A N - P H A S E X V 1/4" = 1'-0"1 PARTIAL HVAC FLOOR PLAN CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . By Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 GL E N A I R L O G I S T I C S - B L D G 2 Au t h o r Ch e c k e r M15-3.0 CO M P L I A N C E E N E R G Y F O R M S - PH A S E X V DA T E O F I S S U E . E1.0 6477 DD DT EL E C T R I C A L L I G H T I N G A N D P O W E R P L A N S 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 GL E N A I R L O G I S T I C S - B L D G . 2 PH A S E X V TH A A D R O O M 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 A B C D E F G H F.7 F.3 G.5 7 PLOT PLAN EXISTING N.I.C. AREA OF THIS T.I. THESE DRAWINGS ARE THE SOLE PROPERTY OF KENT ELECTRIC, INC., A STATE LICENSED C-10 CONTRACTOR, RESPONSIBLE FOR THEIR PREPARATION. PER SECTION 5537.2 OF THE CALIFIORNIA STATE BUSINESS AND PROFESSIONS CODE, THESE DRAWINGS MAY ONLY BE USED FOR WORK THAT KENT ELECTRIC, INC. HAS CONTRACTED TO PERFORM. THESE DRAWINGS HAVE BEEN PREPARED AS A SCHEMATIC REPRESENTATION FOR A PENDING CONSTRUCTION CONTRACT, AND DO NOT NECESSARILY SHOW ALL EQUIPMENT AND MATERIALS NECESSARY TO PROVIDE A COMPLETE PROJECT. THESE DRAWINGS ARE NOT TO BE USED FOR PROJECT CONSTRUCTION BY ANY ENTITY OTHER THAN KENT ELECTRIC, INC., ITS AUTHORIZED AGENTS, OR EMPLOYEES. ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE CONTRACTOR AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE CONTRACTOR. REFERENCE NORTH ELECTRICAL POWER PLANELECTRICAL LIGHTING PLAN DESCRIPTIONSYMBOLTYPE LAMP LIGHTING FIXTURE SCHEDULE WATTSVOLTS BUILDING TWO TITLE ELECTRICAL SHEET INDEX SHEET 14 E 14 T 12 13 E EXISTING RUBERTA SWING ARM AREA N.I.C. EXISTING FIBER ROOM N.I.C. EXISTING PANEL FP SURFACE 400A GRIDLINE D 12 LUGS ONLY<9‘: EATONLOCATION :BUS : MTG : VOLT : MAIN : LIGHTING CONTROLS LEGEND SYMBOL DESCRIPTION UPDATE THE TYPEWRITTEN DIRECTORY AT THE PANELBOARD. SEE CEC 408.4 (A) PROVIDE COMMON TRIP HANDLE TIES ON BREAKERS WHOSE CIRCUITS SHARE A NEUTRAL. SEE CEC 210.4 NEW BREAKERS OF SAME AIC RATING AS THE HIGHEST RATED EXISTING BREAKER IN THE PANEL.N = D D DESCRIPTIONITEM THAAD ROOM EQUIPMENT LIST PHASEVOLTS AMPS REMARKS DA T E O F I S S U E . T24-1 6477 DD DT EN E R G Y F O R M S 12 3 5 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 GL E N A I R L O G I S T I C S - B L D G . 2 PH A S E X V TH A A D R O O M THESE DRAWINGS ARE THE SOLE PROPERTY OF KENT ELECTRIC, INC., A STATE LICENSED C-10 CONTRACTOR, RESPONSIBLE FOR THEIR PREPARATION. PER SECTION 5537.2 OF THE CALIFIORNIA STATE BUSINESS AND PROFESSIONS CODE, THESE DRAWINGS MAY ONLY BE USED FOR WORK THAT KENT ELECTRIC, INC. HAS CONTRACTED TO PERFORM. THESE DRAWINGS HAVE BEEN PREPARED AS A SCHEMATIC REPRESENTATION FOR A PENDING CONSTRUCTION CONTRACT, AND DO NOT NECESSARILY SHOW ALL EQUIPMENT AND MATERIALS NECESSARY TO PROVIDE A COMPLETE PROJECT. THESE DRAWINGS ARE NOT TO BE USED FOR PROJECT CONSTRUCTION BY ANY ENTITY OTHER THAN KENT ELECTRIC, INC., ITS AUTHORIZED AGENTS, OR EMPLOYEES. ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE CONTRACTOR AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE CONTRACTOR. BUILDING TWO *52660$1 63((5$662&,$7(6,1&6758&785$/(1*,1((56 +$+1$9(18(68,7(*/(1'$/(&$/,)251,$  ‡)$;   HPDLOHQJLQHHUV#JURVVPDQVSHHUFRP )25 3$*( *+RSNLQV ,QGH[ %< '$7( 96 '(6&5,37,21 3$*( 1HZ:DOO6WXG+HDGHUDQG-DPE&KHFNV  ([LVWLQJ:DOO6WXG+HDGHUDQG-DPE&KHFNV  6WUXFWXUDO&DOFXODWLRQV 352-(&7180%(5  352-(&7 $UFDGLD%OGJ3KDVH;97KDG5RRP 68%-(&7 &RYHU6KHHW  *52660$1 63((5$662&,$7(6,1&6758&785$/(1*,1((56 +$+1$9(18(68,7(*/(1'$/(&$/,)251,$  ‡)$;   HPDLOHQJLQHHUV#JURVVPDQVSHHUFRP )25 3$*( *+RSNLQV %< '$7( 96 &RQGLWLRQ 1HZ&HLOLQJ-RLVWV 660$6WXG'HVLQJDWLRQ 6 <LHOG6WUHQJWK  NVL -RLVW6SDFLQJ   RF 0D[6SDQ  IW &RPSUHVVLRQ)ODQJH)XOO\%UDFHG 'HDG/RDGV 6WHHO6WXGV SVI 7%DUFHLOLQJ SVI Z 0LVFDQG,QVXODWLRQ SVI 7RWDO'HDG/RDG SVI &HLOLQJ/LYH/RDG SVI 6WXG/RDGLQJ Z  SOI0PD[ LQN 2.IRU 0DOORZ LQN 6 # RF 6WXG'HIOHFWLRQ XQIDFWRUHGORDGV ,[  LQ ѐ Z/ (,   LQ 2.IRU /  LQ 6 # RF 1HZ6WHHO6WXG-RLVWV 352-(&7180%(5  352-(&7 $UFDGLD%OGJ3KDVH;97KDG5RRP 68%-(&7  1 *52660$1 63((5$662&,$7(6,1&6758&785$/(1*,1((56 +$+1$9(18(68,7(*/(1'$/(&$/,)251,$  ‡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ѐ Z/ (,   LQ 2.IRU /  LQ 6 # RF 6HHIROORZLQJ(1(5&$/&$QDO\VLVIRUPRUHDFFXUDWHORDGLQJGLDJUDP7KH ORDGLQJRQWKLVDQDO\VLVLVFRQVHUYDWLYH 1HZ,QWHULRU6WHHO6WXG)UDPLQJ 352-(&7180%(5 352-(&7 68%-(&7  $UFDGLD%OGJ3KDVH;97KDG5RRP  2 General Beam Analysis LIC# : KW-06015294, Build:20.22.12.28 GROSSMAN & SPEER ASSOCIATES, INC. (c) ENERCALC INC 1983-2022 DESCRIPTION:New Wall Stud Check Project File: 23153.ec6 Project Title:Engineer:Project ID:Project Descr: General Beam Properties Elastic Modulus ksi29,000.0 2.998Span #1 in^4Area =in^2 Moment of Inertia =Span Length =10.017.50 ft 2.998Span #2 in^4Area =in^2 Moment of Inertia =Span Length =10.02.50 ft Service loads entered. Load Factors will be applied for calculations.Applied Loads Load for Span Number 1Uniform Load : D = 0.0050 ksf, Tributary Width = 1.334 ft, (Interior Partition Load) Load for Span Number 2Uniform Load : D = 0.0050 ksf, Tributary Width = 1.334 ft, (Interior Partition Load) DESIGN SUMMARY Maximum Bending = Load Combination D Only Span # where maximum occurs Span # 1 Location of maximum on span 8.615 ft 0.05955 k Span # where maximum occurs Location of maximum on span Span # 1 Load Combination D Only Maximum Shear = 17.500 ft 0.245k-ft Maximum DeflectionMax Downward Transient Deflection 0.000 in 0 Max Upward Transient Deflection 0.000 in 0Max Downward Total Deflection 0.156 in 1347Max Upward Total Deflection -0.067 in 890 Maximum Forces & Stresses for Load Combinations Span # Summary of Moment Values (k-ft)Load Combination Shear Values (k)Max Stress Ratios MV Mmax -Mmax + Rm VnxMa - Max Mnx/Omega Cb Va MaxMnx Vnx/OmegaSegment Length Overall MAXimum Envelope Dsgn. L = 17.50 ft 1 0.25 -0.02 0.25 0.06 Dsgn. L = 2.50 ft 2 -0.02 0.02 0.02 D Only Dsgn. L = 17.50 ft 1 0.25 -0.02 0.25 0.06 Dsgn. L = 2.50 ft 2 -0.02 0.02 0.02 +0.60D Dsgn. L = 17.50 ft 1 0.15 -0.01 0.15 0.04 Dsgn. L = 2.50 ft 2 -0.01 0.01 0.01 Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections D Only 1 0.1559 8.750 0.0000 0.000 D Only2 0.0000 8.750 -0.0673 2.500 Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Overall MAXimum 0.057 0.076 Overall MINimum D Only 0.057 0.076 +0.60D 0.034 0.046 3 *52660$1 63((5$662&,$7(6,1&6758&785$/(1*,1((56 +$+1$9(18(68,7(*/(1'$/(&$/,)251,$  ‡)$;   HPDLOHQJLQHHUV#JURVVPDQVSHHUFRP )25 3$*( *+RSNLQV %< '$7( 96 &RQGLWLRQ 1HZ,QW%R[HG+HDGHU 660$6WXG'HVLQJDWLRQ6:DOO:HLJKW 660$7UDFN'HVLQJDWLRQ77RWDO SVI <LHOG6WUHQJWK  NVL 6WXG6SDFLQJ   RF 6WXG6SDQ  IW 2SHQLQJZLGWK  IW 2SHQLQJKHLJKW  IW +HLJKWRIZDOODERYHRSHQLQJ  IW &HLOLQJ5RRI:HLJKW  SVI 7ULE:LGWK IW %R[HG+HDGHU&RPSRVHGRI WUDFNV &ULWHULD EDVHGRQ86*6ZHEVLWHDQG$6&( VWXGV6'6  DS  $6&(7DEOH 5S  $6&(7DEOH ,S  $6&(6HFWLRQ ]  +HLJKWRISRLQWRIVXSSRUWRIWRSRIZDOO K  %XLOGLQJKHLJKW +HDGHU6HFWLRQ 6HLVPLF&RHIILFLHQW $6&(6HFWLRQ )S  DS 6'6 :S  ]K  5S,S  :S *RYHUQV )SPD[  6'6 ,S :S :S)SPLQ  6'6 ,S :S :S ZYHUW)S :S 6HLVPLF&RHIILFLHQWVLQ$6' &RQWUROOLQJ&RPELQDWLRQ 6'6 '( )S$6' :S)S$6' SVI ,QWHULRU:LQG/RDGLQ$6' )LQWZLQG SVI +HDGHU/RDGLQJ ZKRUL] &DVH,QWHULRU:LQG/RDGZKRUL] SOI ZYHUW SOI 0PD[KRUL] LQN 0PD[YHUW LQN 0DOORZKRUL] LQN 0DOORZYHUW LQN 0PD[KRUL]0DOORZKRUL]0PD[YHUW0DOORZYHUW  &DVH6HLVPLFZKRUL] SOI ZYHUW SOI 0PD[KRUL] LQN 0PD[YHUW LQN 0DOORZKRUL] LQN 0DOORZYHUW LQN 0PD[KRUL]0DOORZKRUL]0PD[YHUW0DOORZYHUW 2. 6WXG'HIOHFWLRQ XQIDFWRUHGORDGV ,KRUL] LQ,YHUW LQ &DVH,QWHULRU:LQG/RDG ѐKRUL] ZKRUL]/ (,KRUL]  LQ ѐYHUW ZYHUW/ (,YHUW  LQ &DVH6HLVPLF ѐKRUL] ZKRUL]/ (,KRUL]  LQ ѐYHUW ZYHUW/ (,YHUW  LQ /  LQ 2. 1HZ,QWHULRU%R[HG'RRU+HDGHUV 352-(&7180%(5  352-(&7 $UFDGLD%OGJ3KDVH;97KDG5RRP 68%-(&7  4 *52660$1 63((5$662&,$7(6,1&6758&785$/(1*,1((56 +$+1$9(18(68,7(*/(1'$/(&$/,)251,$  ‡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ѐ Z/ (, 3DE (,/  LQ &DVH6HLVPLF ѐ Z/ (, 3DE (,/  LQ 2.IRU /  LQ 6 VWXGV 1HZ,QWHULRU'RRU-DPE6WXGV 352-(&7180%(5  352-(&7 $UFDGLD%OGJ3KDVH;97KDG5RRP 68%-(&7  5 *52660$1 63((5$662&,$7(6,1&6758&785$/(1*,1((56 +$+1$9(18(68,7(*/(1'$/(&$/,)251,$  ‡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ѐKRUL] ZKRUL]/ (,KRUL]  LQ ѐYHUW ZYHUW/ (,YHUW  LQ &DVH6HLVPLF ѐKRUL] ZKRUL]/ (,KRUL]  LQ ѐYHUW ZYHUW/ (,YHUW  LQ /  LQ 2. 1HZ,QWHULRU:LQGRZ+HDGHUV 352-(&7180%(5  352-(&7 $UFDGLD%OGJ3KDVH;97KDG5RRP 68%-(&7  6 *52660$1 63((5$662&,$7(6,1&6758&785$/(1*,1((56 +$+1$9(18(68,7(*/(1'$/(&$/,)251,$  ‡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ѐ Z/ (, 3DE (,/  LQ &DVH6HLVPLF ѐ Z/ (, 3DE (,/  LQ 2.IRU /  LQ 6 VWXGV 1HZ,QWHULRU:LQGRZ-DPEV 352-(&7180%(5  352-(&7 $UFDGLD%OGJ3KDVH;97KDG5RRP 68%-(&7  7 *52660$1 63((5$662&,$7(6,1&6758&785$/(1*,1((56 +$+1$9(18(68,7(*/(1'$/(&$/,)251,$  ‡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ѐ LQ 2.IRU /  LQ 6 # RF 6HHIROORZLQJ(1(5&$/&DQDO\VLVIRULQGHSWK ORDGLQJDQGGHIOHFWLRQFDOFXODWLRQ ([LVWLQJ,QWHULRU6WHHO6WXG)UDPLQJ 352-(&7180%(5 352-(&7 68%-(&7  $UFDGLD%OGJ3KDVH;97KDG5RRP  8 *52660$1 63((5$662&,$7(6,1&6758&785$/(1*,1((56 +$+1$9(18(68,7(*/(1'$/(&$/,)251,$  ‡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ѐKRUL] ZKRUL]/ (,KRUL]  LQ ѐYHUW ZYHUW/ (,YHUW  LQ /  LQ 2. ([LVWLQJ%R[HG'RRU+HDGHUV 352-(&7180%(5  352-(&7 $UFDGLD%OGJ3KDVH;97KDG5RRP 68%-(&7  9 *52660$1 63((5$662&,$7(6,1&6758&785$/(1*,1((56 +$+1$9(18(68,7(*/(1'$/(&$/,)251,$  ‡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ѐ Z/ (, 3DE (,/  LQ 2.IRU /  LQ 6 VWXGV ([LVWLQJ,QWHULRU'RRU-DPEV 352-(&7180%(5  352-(&7 $UFDGLD%OGJ3KDVH;97KDG5RRP 68%-(&7  10 *52660$1 63((5$662&,$7(6,1&6758&785$/(1*,1((56 +$+1$9(18(68,7(*/(1'$/(&$/,)251,$  ‡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ѐKRUL] ZKRUL]/ (,KRUL]  LQ ѐYHUW ZYHUW/ (,YHUW  LQ /  LQ 2. 6HHIROORZLQJ(1(5&$/&)LOHWRVHH KRZZKRUL]ZDVREWDLQHG 6XSSRUW UHDFWLRQ ([LVWLQJ%R[HG:LQGRZ+HDGHUV 352-(&7180%(5  352-(&7 $UFDGLD%OGJ3KDVH;97KDG5RRP 68%-(&7  11 General Beam Analysis LIC# : KW-06015294, Build:20.22.12.28 GROSSMAN & SPEER ASSOCIATES, INC. (c) ENERCALC INC 1983-2022 DESCRIPTION:Line 14 Boxed Header Lateral Loading Project File: 23153.ec6 Project Title:Engineer:Project ID:Project Descr: General Beam Properties Elastic Modulus ksi29,000.0 4.001Span #1 in^4Area =in^2 Moment of Inertia =Span Length =10.024.333 ft Service loads entered. Load Factors will be applied for calculations.Applied Loads Load(s) for Span Number 1Point Load : D = 0.02625 k @ 9.333 ft, (New Wall Stud Seismic Loading onto Ceiling) Uniform Load : D = 0.00230 k/ft, Tributary Width = 1.0 ft, (Existing Wall Weight Seismic (already factored)) Point Load : D = 0.04134 k @ 9.333 ft, (Ceiling Seismic Load (already factored)) Point Load : D = 0.002873 k @ 0.0 ft, (Boxed Header Seismic Loads (already factored)) DESIGN SUMMARY Maximum Bending = Load Combination D Only Span # where maximum occurs Span # 1 Location of maximum on span 9.368 ft 0.06965 k Span # where maximum occurs Location of maximum on span Span # 1 Load Combination D Only Maximum Shear = 0.000 ft 0.549k-ft Maximum DeflectionMax Downward Transient Deflection 0.000 in 0Max Upward Transient Deflection 0.000 in 0 Max Downward Total Deflection 0.440 in 662Max Upward Total Deflection 0.004 in 71320 Maximum Forces & Stresses for Load Combinations Span # Summary of Moment Values (k-ft)Load Combination Shear Values (k)Max Stress Ratios MV Mmax -Mmax + Rm VnxMa - Max Mnx/Omega Cb Va MaxMnx Vnx/OmegaSegment Length Overall MAXimum EnvelopeDsgn. L = 24.33 ft 1 0.55 0.55 0.07D OnlyDsgn. L = 24.33 ft 1 0.55 0.55 0.07+0.60DDsgn. L = 24.33 ft 1 0.33 0.33 0.04 Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections D Only 1 0.4405 11.680 0.0000 0.000 Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Overall MAXimum 0.073 0.054 Overall MINimum D Only 0.073 0.054 +0.60D 0.044 0.032 12 *52660$1 63((5$662&,$7(6,1&6758&785$/(1*,1((56 +$+1$9(18(68,7(*/(1'$/(&$/,)251,$  ‡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ѐ Z/ (, 3DE (,/  LQ 2.IRU /  LQ 6 VWXGV ([LVWLQJ,QWHULRU:LQGRZ-DPEV 352-(&7180%(5  352-(&7 $UFDGLD%OGJ3KDVH;97KDG5RRP 68%-(&7  13 *52660$1 63((5$662&,$7(6,1&6758&785$/(1*,1((56 +$+1$9(18(68,7(*/(1'$/(&$/,)251,$  ‡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ѐKRUL] ZKRUL]/ (,KRUL]  LQ ѐYHUW ZYHUW/ (,YHUW  LQ /  LQ 2. 352-(&7180%(5  352-(&7 $UFDGLD%OGJ3KDVH;97KDG5RRP 68%-(&7 ([LVWLQJ%R[HG'RRU+HDGHUV  14 *52660$1 63((5$662&,$7(6,1&6758&785$/(1*,1((56 +$+1$9(18(68,7(*/(1'$/(&$/,)251,$  ‡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ѐ Z/ (, 3DE (,/  LQ 2.IRU /  LQ 6 VWXGV 352-(&7180%(5  352-(&7 $UFDGLD%OGJ3KDVH;97KDG5RRP 68%-(&7 ([LVWLQJ,QWHULRU'RRU-DPEV  15 *52660$1 63((5$662&,$7(6,1&6758&785$/(1*,1((56 +$+1$9(18(68,7(*/(1'$/(&$/,)251,$  ‡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ѐKRUL] ZKRUL]/ (,KRUL]  LQ ѐYHUW ZYHUW/ (,YHUW  LQ /  LQ 2. 6HHIROORZLQJ(1(5&$/&)LOHWRVHH KRZZKRUL]ZDVREWDLQHG 6XSSRUW UHDFWLRQ 352-(&7180%(5  352-(&7 $UFDGLD%OGJ3KDVH;97KDG5RRP 68%-(&7 ([LVWLQJ%R[HG:LQGRZ+HDGHUV  16 General Beam Analysis LIC# : KW-06015294, Build:20.22.12.28 GROSSMAN & SPEER ASSOCIATES, INC. (c) ENERCALC INC 1983-2022 DESCRIPTION:Line E Boxed Header Lateral Loading Project File: 23153.ec6 Project Title:Engineer:Project ID:Project Descr: General Beam Properties Elastic Modulus ksi29,000.0 4.001Span #1 in^4Area =in^2 Moment of Inertia =Span Length =10.024.333 ft Service loads entered. Load Factors will be applied for calculations.Applied Loads Load(s) for Span Number 1Point Load : D = 0.02625 k @ 9.333 ft, (New Wall Stud Seismic Loading onto Ceiling) Uniform Load : D = 0.00230 k/ft, Tributary Width = 1.0 ft, (Existing Wall Weight Seismic (already factored)) Point Load : D = 0.05540 k @ 9.333 ft, (Ceiling Seismic Load (already factored)) Point Load : D = 0.002873 k @ 0.0 ft, (Boxed Header Seismic Loads (already factored)) DESIGN SUMMARY Maximum Bending = Load Combination D Only Span # where maximum occurs Span # 1 Location of maximum on span 9.368 ft 0.07832 k Span # where maximum occurs Location of maximum on span Span # 1 Load Combination D Only Maximum Shear = 0.000 ft 0.630k-ft Maximum DeflectionMax Downward Transient Deflection 0.000 in 0Max Upward Transient Deflection 0.000 in 0 Max Downward Total Deflection 0.499 in 584Max Upward Total Deflection 0.005 in 63038 Maximum Forces & Stresses for Load Combinations Span # Summary of Moment Values (k-ft)Load Combination Shear Values (k)Max Stress Ratios MV Mmax -Mmax + Rm VnxMa - Max Mnx/Omega Cb Va MaxMnx Vnx/OmegaSegment Length Overall MAXimum EnvelopeDsgn. L = 24.33 ft 1 0.63 0.63 0.08D OnlyDsgn. L = 24.33 ft 1 0.63 0.63 0.08+0.60DDsgn. L = 24.33 ft 1 0.38 0.38 0.05 Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections D Only 1 0.4994 11.680 0.0000 0.000 Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Overall MAXimum 0.081 0.059 Overall MINimum D Only 0.081 0.059 +0.60D 0.049 0.036 17 *52660$1 63((5$662&,$7(6,1&6758&785$/(1*,1((56 +$+1$9(18(68,7(*/(1'$/(&$/,)251,$  ‡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ѐ Z/ (, 3DE (,/  LQ 2.IRU /  LQ 6 VWXGV 352-(&7180%(5  352-(&7 $UFDGLD%OGJ3KDVH;97KDG5RRP 68%-(&7 ([LVWLQJ,QWHULRU:LQGRZ-DPEV  18