HomeMy WebLinkAbout1108 S Baldwin Ave - 2023 - TI Sushi KisenDUARTE ROAD B A L D W I N A V E N U E (E) DINING AREA (NOT A PART) (E) KITCHEN AREA (E) KITCHEN AREA (E) ELECTRICAL ROOM (E) STORAGE (E) MEN'S (E) WOMEN'S SERVICE AREA SERVICE AREA OMAKAZECHARCOAL GRILL (E) ALL-GENDERRESTROOMWET AREA SITE PLAN / VICINITY MAP / SHEET INDEX / PROJECT INFO A-0 ADDRESS: 1108 S BALDWIN AVE., B7, ARCADIA, CA 91007 APN:5778-007-029 SCOPE OF WORKS: TENANT IMPROVEMENT FOR A JAPANESE RESTAURANT - NEW SERVICE AREA - NEW KITCHEN AREA WITH COOKING EQUIPMENT - NEW EXHAUST TYPE I HOODS AND MAKE UP AIR TOTAL AREA: 1,192 SF TYPE OF OCCUPANCY: A-2 TYPE OF CONSTRUCTION: V-B (FIRE SPRINKLERED) BUILDING STOREY: 2 (PROJECT LOCATE AT 1ST FLOOR) DEFERRED PLAN CHECK SUBMITTALS & PERMITS: - EXTERIOR SIGNAGE - FIRE ALARM, FIRE SPRINKLER HVAC WILL NOT BE ALTERED; ACCESSIBLE RESTROOMS WILL NOT BE ALTERED 4SHEET INDEX R e v i s i o n s : P l a n C h e c k N o. : D r a w n B y : C h e c k e d B y : P h a s e : D a t e : C D A P r o j e c t N o. D r a w i n g T i t l e : S t a m p : C l i e n t : P r o j e c t : D r a w i n g No. : SUSHI KISEN 1108 S BALDWIN AVE., B7 ARCADIA, CA 91007 -- 2334 PLAN CHECK CDA PDG + TUSTIN OFFICE 150 EL CAMINO REAL. #112 TUSTIN, CA 92780 PHONE: 714 832 5100 INDUSTRY OFFICE 17528 E. ROWLAND ST, CITY OF INDUSTRY, CA 91748 PHONE: 626 913 8101 - 2022 CBC, CPC, CMC, CEC & CFC - 2022 CALIFORNIA ENERGY EFFICIENCY CODE - 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSC) - CITY MUNICIPAL CODE APPLICABLE CODES 3 DESIGNER: CDA + PDG 17528 E ROWLAND ST CITY OF INDUSTRY, CA 91748 TEL: (626) 590-2368 CONTACT PERSON: RICK WANG PROJECT CONTACTS 2 SITE PLAN 8 N VICINITY MAP 1 N A-0 TITLE SHEET (SITE PLAN / VICINITY MAP / PROJECT CONTACTS) A-1 EQUIPMENT PLAN & SCHEDULE / FINISH SCHEDULE A-1.1 KEY PLAN A-1.2 CALGREEN BUILDING MANDATORY A-1.3 CALGREEN BUILDING MANDATORY A-1.4 CALGREEN BUILDING MANDATORY A-2 ACCESSIBILITY NOTES & DETAILS E-1 ELECTRICAL PLAN & PANEL SCHEDULE E-2 LIGHTING & REFLECTED CEILING PLAN E-3 LIGHTING TITLE-24 P-1 GAS, HOT/COLD WATER P-2 SEWER PLAN M-1 HVAC PLAN M-2 MECHANICAL PLAN M-3 MECHANICAL DETAILS M-4 DUCT WRAP DETAILS M-5 DUCT WRAP DETAILS EN-1 NON RESIDENTIAL T-24 SHEET EN-2 NON RESIDENTIAL T-24 SHEET 6PROJECT SUMMARY PROJECT H.C. PATH OF TRAVEL PUBLIC SIDEWALK PROJECT A-2 5 1.IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE AS-BUILT CONDITIONS. THE GENERAL CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS AND ADVISE THE OWNER AND ARCHITECT IN WRITING OF ANY SITUATION THAT WOULD NOT ALLOW HIM TO PROCEED ON THE BASIS OF THESE DOCUMENTS. 2.GENERAL CONTRACTOR TO NOTIFY THE ARCHITECT FOR ANY DISCREPANCIES FOUND ON THE CONSTRUCTION DOCUMENTS PRIOR TO PROCEEDING. LARGE SCALE DRAWINGS PRECEDENT TO SMALLER SCALE DRAWINGS. 3.THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND PERFORM ALL SELECTIVE REMOVAL WORK REQUIRED FOR THIS CONTRACT. 4.THE ARCHITECT'S SELECTION OF MATERIAL AND DETAILS DOES NOT RELIEVE THE CONTRACTOR OF VERIFYING WITH THEIR SUPPLIER THAT PROPOSED MATERIALS ARE PROPER FOR THE INTENDED APPLICATION AND USE. 5.REFER TO M.E.P. DRAWINGS FOR LAYOUT, SIZE, CIRCUITING AND GENERAL LOCATIONS OF MECHANICAL, ELECTRICAL AND PLUMBING ITEMS. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS. 6.ALL DIMENSIONS SHALL BE VERIFIED IN FIELD BEFORE PROCEEDING WITH WORK. ARCHITECT SHALL BE NOTIFIED OF ANY MODIFICATIONS. 7.ALL DIMENSIONS ARE TO EXT. FACE OF FINISH GYPSUM BOARD UNLESS NOTED OTHERWISE. 8.DOOR DESIGNATIONS IDENTIFY EACH DOOR BY NUMBER ASSOCIATED WITH THE ROOM NUMBER THE DOOR SWINGS INTO. WHEN THE ROOM NUMBER DOES NOT EXIST THE DOOR IS IDENTIFIED BY THE ROOM NUMBER OF CLOSEST ROOM. 9.WORK WHICH CREATES EXCESSIVE NOISE OR DISRUPTION TO TENANT SHALL BE PERFORMED DURING NON-BUSINESS HOURS ONLY. CONTRACTOR TO COORDINATE WITH BUILDING MANAGEMENT. 10.MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION AND FIRE LIFE SAFETY DRAWINGS SHALL BE SUBMITTED FOR PLAN CHECK AS A SEPARATE PACKAGES AND PERMITS SHALL BE OBTAINED, AS REQUIRED, BY THE CONTRACTOR. 11.ALL SPRINKLERS (ALL TYPES), SECURITY CAMERAS, SPEALERS ETC. SHALL BE CENTERED WITHIN CEILING TILE UNLESS OTHERWISE NOTED. 12.LOCATIONS OF SPRINKLER ARE SHOWN FOR ARCHITECTURAL DESIGN INTENT PLACEMENT. SPACING MUST ALSO SATISFY ALL CODES AND THE MORE STRINGENT DIMENSIONS SHALL APPLY. CONTRACTOR SHOULD COORDINATE WITH ARCHITECT IF SPRINKLER SPACING REQUIREMENT IS DIFFERENT FROM REFLECTED CEILING PLANS. 13.CARPET OR CARPET TILE SHALL BE SECURELY ATTACHED; HAVE A FIRM CUSHION, PAD OR BACKING OR NO CUSHION OR PAD, AND HAVE A LEVEL LOOP, TEXTURED LOOP, LEVEL CUT PILE, OR LEVEL CUT/UNCUT PILE TEXTURE. THE MAXIMUM PILE HEIGHT SHALL BE 1/2". EXPOSED EDGES OF CARPET SHALL BE FASTENED TO FLOOR SURFACES AND HAVE TRIM ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE. 14.GFRG ACCESS PANELS TO BE PROVIDED IN ALL HARD LID CEILINGS FOR FIRE DAMPER, MECHANICAL EQUIPMENT, ABOVE CEILING REQUIRED PER CODE. COORDINATE LOCATION OF THE ACCESS PANELS WITH ARCHITECT IF NOT SHOWN ON THE DRAWINGS. 15.MISCELLANEOUS METAL SHOWN ON DRAWINGS ARE FOR DESIGN GUIDE ONLY. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE STRUCTURAL CALCULATION AND INTEGRITY OF MISCELLANEOUS METALS. 16.MILLWORK DRAWINGS ARE FOR DESIGN INTENT ONLY. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE SUPPORT SYSTEM DESIGN AND STRUCTURAL INTEGRITY. 17.WHERE WORK INCLUDED IN THE WORK IS PHYSICALLY CONNECTED TO, IN CONTACT WITH, OR APPLIED TO EXISTING BASE BUILDING CONSTRUCTION (INCLUDING AT CORES AND EXTERIOR WALLS, FLOORS AND CEILINGS), THE RESULTING ASSEMBLIES ARE TO MAINTAIN THE STRUCTURAL FIRE-RESISTIVE AND WATERPROOFER'S INTEGRITY OF THE EXISTING BUILDING CONSTRUCTION. THERE SHOULD BE NO MECHANICAL CONNECTION OF ANY INTERIOR CONSTRUCTION OR FINISHES TO THE BASE BUILDING EXTERIOR CURTAIN WALL. 18.A RATED SEPARATION SHALL BE PROVIDED BETWEEN THE AREA OF WORK AND ANY OCCUPIED AREA OF THE BUILDING. GENERAL NOTES: SERVICE AREA SERVICE AREA OMAKAZECHARCOAL GRILL (E) ALL-GENDER RESTROOMWET AREA (E) LOBBY (156 SF.) (NOT A PART) (E) DINING AREA (NOT A PART) EQUIPMENT PLAN & SCHEDULE / FINISH SCHEDULE A-16 7 MATERIALS NOTES: CEILING PANEL -- The following ceiling panels are approved. U.S. Gypsum #3270 Vinyl Rock 1) Walls and ceilings in all areas except dining area shall be durable, smooth, nonabsorbent, and easily washable with a light colored (light colored is defined as having a light reflectance value of 70% or greater) finish. 2) All counter surfaces including underside shall be durable, smooth, nonabsorbent, easily washable finish (may require stainless steel or high pressure laminate). 3) Tiles in restrooms, service area and kitchen shall be durable, smooth, nonabsorbent, easily washable finish. 4) Flooring under equipment and at the base coves shall be completely smooth. Floor surfaces which contain slip-resistant agents shall be restricted to traffic areas only. 5) All equipment shall be either easily movable (ie., on casters), on min. 6 inch rounded metal legs, or sealed to min. 4 inch solid masonry island with min. three-eighths inch coved radius. 6) Concrete floor must use top-set type ceramic coved base. 7) Water resistant walls (ie. FRP, stainless steel, tiles) are required behind all sinks and dishwashers. Material to be min. 4 ft. high for LA County, min. 8 ft. high for other counties. All restroom walls to have moisture resistant gypsum board backing. 8) A min. 50-foot candles of light measured 30" A.F.F. in prep areas; a min. 20-foot candles of light in sake bar, handwashing areas, utensil washing area, & restrooms; a min. 10-foot candles of light in storage, janitorial area & walk-in cooler. FINISH SCHEDULE NOTES: FLOOR COVERING -- The following are approved. Tiles -- American Olean; Dal Tiles or equivalent. Topset Ceramic Coved Base -- B&W Tile Co. #S-3619T; OTW Inc. #S-3619T Concrete Sealer -- Ameritone #7101, Aque Mix Choice 15 or equivalent. FINISH SCHEDULE DOOR SCHEDULE NO.SIZE TYPE FINISH HRWR.REMARKTHK.MATERIAL A 3'-0"X7'-0"SWINGING PAINT PUSH-PULL1-3/4" B Note 1,2,3,4,5ALUM. W/ GLASS NOTE: 1) Existing 2) Manually operated edge- or surface-mounted flush bolts and surface bolts are prohibited. 3) Glazed panels at locations within 18" above walking surface subject to human impact shall be of tempered glass. 4) Self-closing, tight-fitting door assembly. 5)a. Interior hinged doors and gates: 5lbs max b. Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum. (CBC 11B-404.2.8.1) 1-3/4"SWINGING3'-0"X7'-0"Note 1,2,4,5 C PAINT LEVER R e v i s i o n s : P l a n C h e c k N o. : D r a w n B y : C h e c k e d B y : P h a s e : D a t e : C D A P r o j e c t N o. D r a w i n g T i t l e : S t a m p : C l i e n t : P r o j e c t : D r a w i n g No. : SUSHI KISEN 1108 S BALDWIN AVE., B7 ARCADIA, CA 91007 -- 2334 PLAN CHECK CDA PDG + TUSTIN OFFICE 150 EL CAMINO REAL. #112 TUSTIN, CA 92780 PHONE: 714 832 5100 INDUSTRY OFFICE 17528 E. ROWLAND ST, CITY OF INDUSTRY, CA 91748 PHONE: 626 913 8101 D 9SERVICE COUNTER SECTION N EQUIPMENT SCHEDULE 8 1FULL-HEIGHT PARTITION WALL 2FULL-HEIGHT PARTITION WALL COVE BASE DETAIL 4TOPSET COVE 3 BASE DETAIL --5 ■ ■ ■ ■ ■ ■■ ■ ■ ■ E PAINT LEVER1-3/4"WOODSWINGING3'-0"X6'-8"Note 1,2,4,5 METAL 1 -- 10 -- 10 -- A B C C PAINT LEVER1-3/4"WOODSWINGING3'-0"X6'-8"Note 2,4,5 or adjacent to all disabled accessible building Post International Symbol of Accessibility on entrance. H.C. SIGN TACTILE "EXIT" SIGN EXIT........ 48"x48" CLEAR 60"x60" CLEAR 60"x60" CLEAR 48"x48" CLEAR FLOOR PLAN10 1 -- 2 -- A-2 4 E PAINT SLIDING1-3/4"WOODPOCKET3'-0"X6'-8"Note 2,5 SERVICE COUNTER ELEVATION 11 11-- D D SERVICE AREA SERVICE AREA OMAKAZECHARCOAL GRILL (E) ALL-GENDER RESTROOMWET AREA (E) LOBBY (156 SF.) (NOT A PART) (E) DINING AREA (NOT A PART) (E) KITCHEN AREA (E) KITCHEN AREA (E) ELECTRICAL ROOM (E) STORAGE (E) MEN'S (E) WOMEN'S KEY PLAN A-1.1 R e v i s i o n s : P l a n C h e c k N o. : D r a w n B y : C h e c k e d B y : P h a s e : D a t e : C D A P r o j e c t N o. D r a w i n g T i t l e : S t a m p : C l i e n t : P r o j e c t : D r a w i n g No. : SUSHI KISEN 1108 S BALDWIN AVE., B7 ARCADIA, CA 91007 -- 2334 PLAN CHECK CDA PDG + TUSTIN OFFICE 150 EL CAMINO REAL. #112 TUSTIN, CA 92780 PHONE: 714 832 5100 INDUSTRY OFFICE 17528 E. ROWLAND ST, CITY OF INDUSTRY, CA 91748 PHONE: 626 913 8101 1 N KEY PLAN EGRESS CALCULATION TOTAL OCCUPANTS x 0.3" PER OCC. = 106 x 0.3 = MIN. 32" REQ'D (180" PROVIDED) MIN. EGRESS WIDTH:A OCC. LOAD OF 106 = MIN. 2 EXITS REQ'D (5 EXITS PROVIDED) MIN. EXITS REQUIRED FOR DINING RM.: "A-2" OCCUPANCY (WITH FIRE SPRINKLER): MAX. 250' REQ'D (117' PROVIDED) MAX. TRAVEL DISTANCE: MIN. SEPARATION OF 2 REQ'D EXITS = 50% OF 111' = MIN. 56' REQ'D (95' PROVIDED) B C (1,192 SF.) EXISTING LOBBY AREA: WAITING AREA = 156 S.F./15 PERSONS PER S.F.= 11 PERSONS TOTAL 11 PERSONS EXISTING RESTAURANT AREA: CUSTOMER AREA = 810 S.F./15 PERSONS PER S.F.= 54 PERSONS KITCHEN & SERVICE AREA = 947 S.F./ 200 PERSONS PER S.F.= 5 PERSONS TOTAL 59 PERSONS NEW PROJECT RESTAURANT AREA: CUSTOMER AREA = 474 S.F./15 PERSONS PER S.F.= 32 PERSONS KITCHEN & SERVICE AREA = 718 S.F./ 200 PERSONS PER S.F.= 4 PERSONS TOTAL 36 PERSONS SUB TOTAL 106 PERSONS OCCUPANT CALCULATION SUMMARY OF ACCESSIBILITY UPGRADES 2 PATH OF TRAVEL NOTES: NO ABRUPT CHANGES IN ELEVATION ALONG THE PATH OF TRAVEL SHOWN. THE SLOPE AND CROSS-SLOPE ALONG THE PATH OF TRAVEL SHALL NOT EXCEED 5% AND 2% RESPECTIVELY. INSPECTOR TO VERIFY JANITORIAL SINK DETAIL 3 CALGREEN BUILDING MANDATORY A-1.2 R e v i s i o n s : P l a n C h e c k N o. : D r a w n B y : C h e c k e d B y : P h a s e : D a t e : C D A P r o j e c t N o. D r a w i n g T i t l e : S t a m p : C l i e n t : P r o j e c t : D r a w i n g No. : SUSHI KISEN 1108 S BALDWIN AVE., B7 ARCADIA, CA 91007 -- 2334 PLAN CHECK CDA PDG + TUSTIN OFFICE 150 EL CAMINO REAL. #112 TUSTIN, CA 92780 PHONE: 714 832 5100 INDUSTRY OFFICE 17528 E. ROWLAND ST, CITY OF INDUSTRY, CA 91748 PHONE: 626 913 8101 CALGREEN BUILDING MANDATORY A-1.3 R e v i s i o n s : P l a n C h e c k N o. : D r a w n B y : C h e c k e d B y : P h a s e : D a t e : C D A P r o j e c t N o. D r a w i n g T i t l e : S t a m p : C l i e n t : P r o j e c t : D r a w i n g No. : SUSHI KISEN 1108 S BALDWIN AVE., B7 ARCADIA, CA 91007 -- 2334 PLAN CHECK CDA PDG + TUSTIN OFFICE 150 EL CAMINO REAL. #112 TUSTIN, CA 92780 PHONE: 714 832 5100 INDUSTRY OFFICE 17528 E. ROWLAND ST, CITY OF INDUSTRY, CA 91748 PHONE: 626 913 8101 CALGREEN BUILDING MANDATORY A-1.4 R e v i s i o n s : P l a n C h e c k N o. : D r a w n B y : C h e c k e d B y : P h a s e : D a t e : C D A P r o j e c t N o. D r a w i n g T i t l e : S t a m p : C l i e n t : P r o j e c t : D r a w i n g No. : SUSHI KISEN 1108 S BALDWIN AVE., B7 ARCADIA, CA 91007 -- 2334 PLAN CHECK CDA PDG + TUSTIN OFFICE 150 EL CAMINO REAL. #112 TUSTIN, CA 92780 PHONE: 714 832 5100 INDUSTRY OFFICE 17528 E. ROWLAND ST, CITY OF INDUSTRY, CA 91748 PHONE: 626 913 8101 ACCESSIBILITY NOTES & DETAILS Fig. 8 Fig.7GRAB BAR DETAIL Fig. 6 TRAFFIC ENFORCEMENT OFFICER PARKED IN THE SPACE (CENTEREDWHEN A VEHICLE IS PROPERLY RECOMMENDED) AT ENTRANCE TO STALL EMBLEM MUST BE LOCATED INSTALL SO THAT IS VISIBLE BY A C A B Fig. 5ACCESSIBLE PARKING STALL 1. EACH SPACE FOR THE DISABLED IS REQUIRED TO BE IDENTIFIED BY A PERMANENT , REFLECTORIZED SIGN WITH THE INTERNATIONAL SYMBOL OF ACCESSIBLITY. 2. THE SURFACE OF EACH SPACE FOR THE DISABLED IS REQUIRED TO HAVE A 3 FOOT SQUARE INTERNATIONAL SYMBOL OF ACCESSIBILITY ATENELED IN BLUE PAINT. 3. AT THE ENTRANCE TO OFFSTREET PARKING FACUTIES. A CONSPICUOUS SIGN AT LEAST 17" BY 22" IS REQUIRED. FOR SIGN INFORMATION. ACCESSIBLE RESTROOM DETAILS 1. 1-1/4" TO 1-1/2" ROUND STEEL BARS WITH 1-1/2" CLEARANCE (FOR TANK TYPE TOILETS. SOAP DISPENSER. TOILET PAPER HOLDER. (TILE, CEMENT, MARLITE ETC). PAPER TOWEL DISPENSER. 36" ABOVE FLOOR MAY BE ALLOWED IF TANK 2. PROVIDE SOLID BACKING FOR MOUNTING 3. NO ROTATION PERMITTED IF FITTINGS USED. TOILET SEAT COVER DISPENSER. SMOOTH, HARD, NONABSORBENT SURFACE OF BARS. MIRROR OBSTRUCTS PLACEMENT OF BARS). GRAB BAR: UNDER LAVATORY. 1. NO SHARP OR ABRASIVE SURFACES 2. LEVER FAUCET CONTROLS OPERABLE. 3. HOT WATER SUPPLY AND DRAIN PIPING INSULATED. 1. FLUSH CONTROL HANDLE ON WIDE SIDE WITH 3 LBS. MAXIMUM OPERATING FORCE. WATER CLOSET: LAVATORY: WITH ONE HAND AND 5 LBS. MAXIMUM FORCE. TOILET A E D F J C G H J 1 LAVATORY2 SHALL COMPLY WITH LABC 6.302.4 TOILET ROOM VIEW SCREEN Fig. 4 DRAWN BY JIMMY ZHANG (6 2 6 ) 5 7 0 - 9 9 7 8 DESIGN FOR RESTAURANT PLU S , I N C . Fig. 1 ACCESSORIES IN SANITARY FACILITIES SIGNAGE CORRIDORS AND AISLES SANITARY FACILITY FIXTURES AND ACCESSORIES MULTIPLE ACCOMMODATION SANITARY FACILITIES LAVATORIES ACCESSORIES IN SANITARY FACILITIES Fig. 9TRUNCATED DOME If a walk crosses or adjoins a vehicular way, and the walking surfaces are not separated by curbs, railings or other elements between the pedestrian areas and vehicular areas, the boundary between the areas shall be defined by a continuous detectable warning (per 11B-705.1) which is 36" wide. Food Service Lines/Aisles Fig. 2appropriate signage. SITE ACCESSIBLE ROUTE OF TRAVEL At least one accessible route within the boundary of the state is provided to an accessible building entrance from: Public transportation stops Accessible parking spaces Accessible passenger loading zones Public streets and sidewalks At every primary public entrance and at every major junction along or leading to an accessible route of travel, there shall be a sign displaying the international symbol of comply with the requirements: accessibility. Signs shall indicate the direction to accessible building entrances and facilities and shall Accessible entrances and routes of travel have Entrance signage 11B-703.7.2.1 11B-206.2.1 Counters 60" ACCESSORIES IN SANITARY FACILITIES Fig. 3 DOORS ENTRANCES AND EXITS WALKS & SIDEWALKS PARKING SIGNAGE 2-- 1-- (E) ALL-GENDER RESTROOM H. F. G. E. D. recommended).11118B.4.thru B.6 52.4. If medicine cabinets are provided, at least one has a usable shelf no higher than 44" above floor.4.23.9 Operable parts (including coin slots) of all fixtures or accessories are located a maximum of 40" above floor (i.e., soap dispensers, towels toilet seat covers, auto- dryers, sanitary napkin dispensers, waste receptacles, Controls and operating mechanisms are operable with one hand and do not require tight grasping, pinching, The force required to activate controls is 5 lb. max. Coat hooks and shelving are located within appropriate reach ranges (48" max. above floor 6.or twisting of the wrist. 27.6.1117B.4 4. 1115B.etc.).9.2 1117B.4 4 Fig.9174.23. 27.4.4 4" WIDE PAINTED PARK'G STRIPES: 2-COATS OF BLUE AT DISABLED STALLS OCCUPANT IN WHITE ON BLUE BACKGROUND SHALL BE 36" WIDE TYP. DISABLED STALL SIGN TYP. PRECAST CONC. WHEEL STOP NO PARKING 2% S L O P E M A X . STRIPES AT 36" O.C. "NO PARKING" LETTERS 12" HI. MIN. CURB FACE 6B -- 1:12 MAX SLOPE DN 1/4" DEEP GROOVES 3/4"Ø O.C. (12" WIDTH MIN.) EXISTING BUILDING 1:12 MAX SLOPE DN ACCESSIBILITY NOTES & DETAILS A-2 R e v i s i o n s : P l a n C h e c k N o. : D r a w n B y : C h e c k e d B y : P h a s e : D a t e : C D A P r o j e c t N o. D r a w i n g T i t l e : S t a m p : C l i e n t : P r o j e c t : D r a w i n g No. : SUSHI KISEN 1108 S BALDWIN AVE., B7 ARCADIA, CA 91007 -- 2334 PLAN CHECK CDA PDG + TUSTIN OFFICE 150 EL CAMINO REAL. #112 TUSTIN, CA 92780 PHONE: 714 832 5100 INDUSTRY OFFICE 17528 E. ROWLAND ST, CITY OF INDUSTRY, CA 91748 PHONE: 626 913 8101 ELECTRICAL PLAN & PANEL SCHEDULE E-1ELECTRICAL LEGEND 2 R e v i s i o n s : P l a n C h e c k N o. : D r a w n B y : C h e c k e d B y : P h a s e : D a t e : C D A P r o j e c t N o. D r a w i n g T i t l e : S t a m p : C l i e n t : P r o j e c t : D r a w i n g No. : SUSHI KISEN 1108 S BALDWIN AVE., B7 ARCADIA, CA 91007 -- 2334 PLAN CHECK CDA PDG + TUSTIN OFFICE 150 EL CAMINO REAL. #112 TUSTIN, CA 92780 PHONE: 714 832 5100 INDUSTRY OFFICE 17528 E. ROWLAND ST, CITY OF INDUSTRY, CA 91748 PHONE: 626 913 8101 1PANEL SCHEDULE 3MANDATORY MEASURES ELECTRICAL NOTES 4 N 6ELECTRICAL PLAN SERVICE AREA SERVICE AREA OMAKAZECHARCOAL GRILL (E) ALL-GENDER RESTROOM WET AREA EXIT SIGN W/ EMERGENCY LIGHTING THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR. THE INSTALLATION OF THE EMERGENCY POWER SYSTEM SHALL BE IN ACCORDANCE WITH SECTION 2702 EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1 FOOTCANDLE MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FOOTCANDLE AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOTCANDLE AT THE END OF THE EMERGENCY LIGHTING TIME DURATION. A MAXIMUM-TO-MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED. ( CBC 1008) LIGHTING SHUT-OFF DIAGRAM 3 KEY NOTES: REFLECTED CEILING AND LIGHTING PLAN E-2 R e v i s i o n s : P l a n C h e c k N o. : D r a w n B y : C h e c k e d B y : P h a s e : D a t e : C D A P r o j e c t N o. D r a w i n g T i t l e : S t a m p : C l i e n t : P r o j e c t : D r a w i n g No. : SUSHI KISEN 1108 S BALDWIN AVE., B7 ARCADIA, CA 91007 -- 2334 PLAN CHECK CDA PDG + TUSTIN OFFICE 150 EL CAMINO REAL. #112 TUSTIN, CA 92780 PHONE: 714 832 5100 INDUSTRY OFFICE 17528 E. ROWLAND ST, CITY OF INDUSTRY, CA 91748 PHONE: 626 913 8101 1 KEY NOTES: LIGHTING SHUT-OFF DIAGRAM 2LIGHTING INSTALLATION 6REFLECTED CEILING AND LIGHTING PLAN 2MANDATORY MEASURES N SEISMIC DESIGN CATEGORY "D": (CBC 803.9, ASCE 7-16 SEC. 13.5.6 AND CISCA 3-4) - HEAVY-DUTY GRID SYSTEM - MIN. 2" WALL MOLDING - ATTACHED GRID ON 2 ADJACENT WALLS - 3/4" CLR. AT PERIMETER ON UNATTACHED WALLS. MAX. LENGTHS FOR VERTICAL STRUT: EMT CONDUIT 1/2" EMT CONDUIT- UP TO 3'-11" 3/4" EMT CONDUIT- UP TO 6'-4" 1" EMT CONDUIT- UP TO 9'-9" METAL STUD 250S137-33 UP TO 6'-10" 250S137-43 UP TO 8'-10" 400S137-43 UP TO 10'-10" SUSPENDED CEILING DETAIL 4 EF #1 EF #2 EF #3 MA #1 MA #2 MA #3 TC ENERGY CALCULATION E-3 R e v i s i o n s : P l a n C h e c k N o. : D r a w n B y : C h e c k e d B y : P h a s e : D a t e : C D A P r o j e c t N o. D r a w i n g T i t l e : S t a m p : C l i e n t : P r o j e c t : D r a w i n g No. : SUSHI KISEN 1108 S BALDWIN AVE., B7 ARCADIA, CA 91007 -- 2334 PLAN CHECK CDA PDG + TUSTIN OFFICE 150 EL CAMINO REAL. #112 TUSTIN, CA 92780 PHONE: 714 832 5100 INDUSTRY OFFICE 17528 E. ROWLAND ST, CITY OF INDUSTRY, CA 91748 PHONE: 626 913 8101 R e v i s i o n s : P l a n C h e c k N o. : D r a w n B y : C h e c k e d B y : P h a s e : D a t e : C D A P r o j e c t N o. D r a w i n g T i t l e : S t a m p : C l i e n t : P r o j e c t : D r a w i n g No. : SUSHI KISEN 1108 S BALDWIN AVE., B7 ARCADIA, CA 91007 -- 2334 PLAN CHECK CDA PDG + TUSTIN OFFICE 150 EL CAMINO REAL. #112 TUSTIN, CA 92780 PHONE: 714 832 5100 INDUSTRY OFFICE 17528 E. ROWLAND ST, CITY OF INDUSTRY, CA 91748 PHONE: 626 913 8101 PLUMBING PLAN P-1TRAP PRIMER DETAIL PIPE MATERIAL SCHEDULE 3 6PLUMBING FIXTURE SCHEDULE 4 5VENT DETAIL NOTE: 2 1 3 2GAS LINE SIZING CALCULATION HOT & COLD WATER PLAN 7 N 1WATER HEATER G (E) GAS METER w (E) WATER METER 1 1-1/4" S.O.V. (277 CF/H) 1" S.O.V. (192 CF/H) 2 3 4 4 3/ 4 " G 1-1/4" G 1" G 1-1/2" G1-1/4" G 3/4" G(E) WATER SUPPLY (E) 1/2" CW (E ) 1 / 2 " C W (E ) 1 / 2 " H W 3/ 4 " C W 3/ 4 " H W 1/2" HW 1/2" CW 1/2" CW 1/2" CW 1/2" HW 1/2" HW1/ 2 " H W 1/2" CW 1/ 2 " C W 1/ 2 " H W 1/ 2 " C W SEWER PLAN P-2PIPE MATERIAL SCHEDULE 3 DRAINAGE PLAN N SLAP REPAIR 5 1 GAS ISOMETRIC 4 R e v i s i o n s : P l a n C h e c k N o. : D r a w n B y : C h e c k e d B y : P h a s e : D a t e : C D A P r o j e c t N o. D r a w i n g T i t l e : S t a m p : C l i e n t : P r o j e c t : D r a w i n g No. : SUSHI KISEN 1108 S BALDWIN AVE., B7 ARCADIA, CA 91007 -- 2334 PLAN CHECK CDA PDG + TUSTIN OFFICE 150 EL CAMINO REAL. #112 TUSTIN, CA 92780 PHONE: 714 832 5100 INDUSTRY OFFICE 17528 E. ROWLAND ST, CITY OF INDUSTRY, CA 91748 PHONE: 626 913 8101 (E) 3" S (E) 3" FCO. 3" FCO. 2" S 1-1/2" S 3" GS 3" FCO. 3" G S 3" FCO. 1-1/2" S 3" GS 3" GS EXISTING MAIN SEWER 1-1/2" S 3" S 1-1/2" S (E) 3"VTR. 2" G S 2" GS 6PLUMBING FIXTURE SCHEDULE 7PLUMBING FIXTURE SCHEDULE 3"S (N) 3"VTR. 3" S 3" S 3" WCO. 3" GS ENERGY COMPLIANCE (PLUMBING) EN-1 R e v i s i o n s : P l a n C h e c k N o. : D r a w n B y : C h e c k e d B y : P h a s e : D a t e : C D A P r o j e c t N o. D r a w i n g T i t l e : S t a m p : C l i e n t : P r o j e c t : D r a w i n g No. : SUSHI KISEN 1108 S BALDWIN AVE., B7 ARCADIA, CA 91007 -- 2334 PLAN CHECK CDA PDG + TUSTIN OFFICE 150 EL CAMINO REAL. #112 TUSTIN, CA 92780 PHONE: 714 832 5100 INDUSTRY OFFICE 17528 E. ROWLAND ST, CITY OF INDUSTRY, CA 91748 PHONE: 626 913 8101 BK 64 6 A r m i t o s P l a c e D i a m o n d B a r , C A 9 1 7 6 5 T : 9 0 9 . 5 6 9 . 2 5 8 6 E m a i l : b k e n g i n e e r s 8 8 @ g m a i l . c o m C O N S U L T I N G E N G I N E E R S I N C 12/28/23 M 22176 ENERGY COMPLIANCE (HOOD) EN-2 R e v i s i o n s : P l a n C h e c k N o. : D r a w n B y : C h e c k e d B y : P h a s e : D a t e : C D A P r o j e c t N o. D r a w i n g T i t l e : S t a m p : C l i e n t : P r o j e c t : D r a w i n g No. : SUSHI KISEN 1108 S BALDWIN AVE., B7 ARCADIA, CA 91007 -- 2334 PLAN CHECK CDA PDG + TUSTIN OFFICE 150 EL CAMINO REAL. #112 TUSTIN, CA 92780 PHONE: 714 832 5100 INDUSTRY OFFICE 17528 E. ROWLAND ST, CITY OF INDUSTRY, CA 91748 PHONE: 626 913 8101 BK 64 6 A r m i t o s P l a c e D i a m o n d B a r , C A 9 1 7 6 5 T : 9 0 9 . 5 6 9 . 2 5 8 6 E m a i l : b k e n g i n e e r s 8 8 @ g m a i l . c o m C O N S U L T I N G E N G I N E E R S I N C KRISHNA KUMAR BK CONSULTING ENGINEERS INC 646 ARMITOS PLACE DIAMOND BAR, CA 91765 KRISHNA KUMAR BK CONSULTING ENGINEERS INC 646 ARMITOS PLACE DIAMOND BAR, CA 91765 12/28/23 M 22176 909 569 2586 12/28/23 909 569 2586