Loading...
HomeMy WebLinkAbout201 E Live Oak Ave - 2023 - CARPORT MOUNTED SOLAR SYSTEM 72 MODULES/3 INVERTERSI HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF ARCADIA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF ARCADIA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: 201 E. LIVE OAK 201 E. LIVE OAK ARCADIA, CA 91006 NO.DATE DESCRIPTION STRUC. 1 CONTRACTOR TRUE POWER SOLAR 201 CLARK AVE POMONA, CA 91767 CSLB #: 970591/ B, C46 714-676-8888 9/13/2022 INITIAL PLAN SET -- ELECT. P.R. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: 970591/ B, C46 1/9/2023 CORRECTION 1 P.R. 5/11/2023 CORRECTION 3 P.R. DRAWING INDEX 201 E. LIVE OAK 201 E. LIVE OAKARCADIA, CA 91006 SYSTEM INFORMATION SCOPE OF WORK VICINITY MAP CITY APPROVAL STAMPS LEGAL DESCRIPTION PV 1 COVER PAGE PARCEL MAP ABBREVIATIONS PROPERTY LOCATION PHOTOVOLTAIC GENERAL NOTES · · · · · · · · 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 32 33 34 35 36 37 38 39 40 41 30 31 CARPORT WITH PHOTOVOLTAIC MODUELS UNDER SEPARATE PERMIT # COMM-23-0813 G72 17 16 15 14 13 12 11 10 18 ENTRY ENTRY 25 01 26 PROPERTY LINE LIVE OAK AVE 02 201 E LIVE OAK AVE SINK MOP FD 9 JAN CL 24 03 04 05 06 19 07 20 21 22 G72 09 PARKING LOT 2N D A V E PR O P E R T Y L I N E PR O P E R T Y L I N E SE T B C K SE T B A C K LI N E O F B U I L D I N G A B O V E PROPERTY LINE 25'-0"R < > X C L R F R O M I N T E R S E C T I O N I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF ARCADIA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF ARCADIA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: 201 E. LIVE OAK 201 E. LIVE OAK ARCADIA, CA 91006 NO.DATE DESCRIPTION STRUC. 1 CONTRACTOR TRUE POWER SOLAR 201 CLARK AVE POMONA, CA 91767 CSLB #: 970591/ B, C46 714-676-8888 9/13/2022 INITIAL PLAN SET -- ELECT. P.R. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: 970591/ B, C46 1/9/2023 CORRECTION 1 P.R. 5/11/2023 CORRECTION 3 P.R. SITE PLAN SCALE: 1/8" = 1'-0" N S E W PV 2 SITE PLAN PV MODULE ARRAY INFORMATION ARRAY A ROOF PITCH N/A FRAMING SEE S-1 MODULE COUNT 72 MODULE AREA 1648.1SQ.FT. ARRAY TILT 5° ARRAY AZIMUTH 270° 3'-0" 20'-7" 7'-0" 80'-7" 15'-6" 19'-6" 23'-0" 1'-2" LOW SIDE HIGH SIDE E. PROPERTY LINE E. MAIN ELECTRICAL SERVICE METER/SWITCHBOARD 2'-9" 17 16 15 14 13 12 11 10 18 ENTRY ENTRY 25 01 26 PROPERTY LINE 02 201 E LIVE OAK AVE SINK MOP FD 9 JAN CL 24 03 04 05 06 19 07 20 21 22 G72 09 PARKING LOT 2N D A V E PR O P E R T Y L I N E PR O P E R T Y L I N E SE T B C K SE T B A C K LI N E O F B U I L D I N G A B O V E - 1 S1 - 1 S1 - 1 S2 - 2 S1 - 2 S2 - 3 S1 - 3 S2 - 2 S1 - 2 S2 - 3 S1 - 3 S2 - 1 S2 2'-2" O.C. 15 ' - 4 " 6'-8" 4' MIN 6'-3" MAX 20'-8" 3'-5" P.L. (WALL)PARKING WHEEL STOP 3'-9" 3' 13 ' - 6 " 5 ° 01 02 03 04 05 06 07 G7 2 09 I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF ARCADIA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF ARCADIA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: 201 E. LIVE OAK 201 E. LIVE OAK ARCADIA, CA 91006 NO.DATE DESCRIPTION STRUC. 1 CONTRACTOR TRUE POWER SOLAR 201 CLARK AVE POMONA, CA 91767 CSLB #: 970591/ B, C46 714-676-8888 9/13/2022 INITIAL PLAN SET -- ELECT. P.R. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: 970591/ B, C46 1/9/2023 CORRECTION 1 P.R. 5/11/2023 CORRECTION 3 P.R. PV 3 PLOT PLAN N S E W 1 - S1 PLOT PLAN PLAN LEGEND SCALE: 1/8" = 1'-0" ELECTIRCAL ELEVATION VIEW SCALE: 1/4" = 1'-0" ELEVATION VIEW SCALE: 3/16" = 1'-0" A - B - PARKING SPACES SCALE: 1/8" = 1'-0" C - 1 2 5 3 4 4 4 B PV3 A PV3 C PV3 E. MAIN ELECTRICAL SERVICE METER/SWITCHBOARD 1 2 20'-0" 6'-0" TO EDGE OF CANOPY ABOVE 6'-9" TO CENTER OF COLUMN 9'-0" NOTE: EXISTING PARKING SPACE DIMENSIONS - 20' X 9' 18'-0"18'-0"18'-0"9'-0" 11'-0" PROPOSED CARPORT COLUMN TO BE 11'-0" FROM EXISTING TRASH ENCLOSURE 22'-1" 22'-1" 8'-9" 8'-10" 2'-2" N. CARPORT GROUND ROD LOCATIONS 3'-0" TO EDGE OF CANOPY ABOVE 2'-9" #EQUIPMENT DESCRIPTION 1 SUNPOWER SPR-M460-COM SUNPOWER 460W SOLAR MODULE 2 SOLAREDGE SE-10000H-US[240V] SOLAREDGE 10KW SOLAR INVERTER, W/ INTEGRATED DC DISCONNECT 3 JUNCTION BOX JUNCTION BOX 4 DC/DC OPTIMIZER P505, 505W DC/DC OPTIMIZER 5 EATON OR EQUIVALENT 200A PV SYSTEM AC COMBINER PANEL, 240V, 1Ø-3W 65KAIC 6 EATON OR EQUIVALENT 200A PV SYSTEM AC SAFETY DISCONNECT SWITCH, 240V, 1Ø-3W 65KAIC. NON-FUSED. LOCKABLE IN THE OPEN POSITION, BLADE TYPE VISIBLE OPEN 200A 240V/120V 1Ø 3W NEMA 3R 65KAICSOLAR COMBINER PANEL - DO NOT ADD LOADS 1P-PV (N)60A 5 BREAKERS RATED FOR 65KAIC MTO EXISTING LOADS (E) 400A SWITCHGEAR - 1Ø, 3W, 240V/120V - NEMA 3R, 65KAIC METER #: SCE EXISTING 400AT 65KAIC @ 240V TO UTILITY 705.12(B)(2)(3)(c) SUM OF ALL OVERCURRENT DEVICES 157.5A ≤ 100% BUS RATING 157.5A ≤ 200A OK 3P (N)200A GND 6 D ~10FT E ~10FT MPPT1 3 2 B A C 1 + 1 - GND MPPT2 MPPT3 MPPT1 3 2 B A C MPPT2 MPPT3 MPPT1 3 2 B A C MPPT2 MPPT3 4 600A MAX RATING I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF ARCADIA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF ARCADIA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: 201 E. LIVE OAK 201 E. LIVE OAK ARCADIA, CA 91006 NO.DATE DESCRIPTION STRUC. 1 CONTRACTOR TRUE POWER SOLAR 201 CLARK AVE POMONA, CA 91767 CSLB #: 970591/ B, C46 714-676-8888 9/13/2022 INITIAL PLAN SET -- ELECT. P.R. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: 970591/ B, C46 1/9/2023 CORRECTION 1 P.R. 5/11/2023 CORRECTION 3 P.R. EQUIPMENT NOTES 1 2 3 4 5 PV 4 SINGLE LINE DIAGRAM CARPORT EXTERIOR MAIN BUILDING - GROUND FLOOR MINIMUM COVER REQUIREMENTS, 0 TO 1000 VOLTS, NOMINAL, BURIAL IN INCHES SCHEDULE 40/80 CONDUIT MINIMUM BURIAL DEPTH IN A TRENCH BELOW 2" OF THICK CONCRETE OR EQUIVALENT 18" UNDER MINIMUM OF 4" THICK CONCRETE EXTERIOR SLAB WITH NO VEHICULAR TRAFFIC AND TE SLAB EXTENDING NOT LESS THAN 6" BEYOND THE UNDERGROUND INSTALLATION 18" UNDER STREETS, HIGHWAYS, ROADS, ALLEYS, DRIVEWAYS, AND PARKING LOTS SUBJECT TO VEHICULAR TRAFFIC 24" UNDER A BUILDING 0" NOT OTHERWISE SPECIFIED 24" *REFERENCED FROM THE NEC 2014 TABLE 300.5 I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF ARCADIA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF ARCADIA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: 201 E. LIVE OAK 201 E. LIVE OAK ARCADIA, CA 91006 NO.DATE DESCRIPTION STRUC. 1 CONTRACTOR TRUE POWER SOLAR 201 CLARK AVE POMONA, CA 91767 CSLB #: 970591/ B, C46 714-676-8888 9/13/2022 INITIAL PLAN SET -- ELECT. P.R. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: 970591/ B, C46 1/9/2023 CORRECTION 1 P.R. 5/11/2023 CORRECTION 3 P.R. PV 5 GROUNDING MODULES PURLIN TO BEAM GROUNDING COLUMN TO INVERTER GROUNDING SCALE: NTS MODULE GROUND BOND WITH LAY IN LUGS ILSCO GBL-4DBTH OR EQUAL WIREWAY BOND BEAMS TO STRUCTURE COLUMNS WITH LAY IN LUGS ILSCO GBL-4DBTH OR EQUAL #8 BARE CU GND MODULE TO MODULE GROUNDING MODULE TO PURLIN GROUNDING PURLIN TO PURLIN GROUNDING BEAM TO COLUMN GROUNDING BOND PURLINS JOINT WITH LAY IN LUGS ILSCO GBL-4DBTH OR EQUAL #8 BARE CU GND BOND PURLINS WITH LAY IN LUGS ILSCO GBL-4DBTH OR EQUAL #8 BARE CU GND BOND BEAMS WITH LAY IN LUGS ILSCO GBL-4DBTH OR EQUAL #8 BARE CU GND (E) MAIN SWITCHBOARD STRING INVERTER (TYP.)AC COMBINER PANEL MAIN SOLAR AC DISCONNECT GROUNDING BUSHING (TYP.) DC AC GND GND GND GND GND UNSPLICED OR IRREVERSIBLYUNSPLICED #6 COMBINED DC GEC AND AC EGC PER NEC 690.47 (C). UNSPLICED OR IRREVERSIBLY COMBINED DC GEC AND AC EGC PER NEC 690.47 (C). COMBINED DC GEC AND AC EGC PER NEC 690.47 (C). (E) BUILDING GROUNDING ELECTRODE SCALE: NTSGROUND CARPORT COLUMN USING UL2703 APPROVED GROUND LUG TO GROUND ROD #6 CU. GND 8' MIN 6'SCALE: NTS GROUND ROD SEPARATION (A) MODULE GROUNDING ON CARPORT #8 CU. GND #6 CU. GND #6 CU. GND#8 CU. GND CARPORT COLUMN CARPORT COLUMN ENTRY -1 S1 -1 S1 -1 S2-2 S1-2 S2-3 S1-3 S2 -2 S1 -2 S2 -3 S1 -3 S2 -1 S2 I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF ARCADIA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF ARCADIA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: 201 E. LIVE OAK 201 E. LIVE OAK ARCADIA, CA 91006 NO.DATE DESCRIPTION STRUC. 1 CONTRACTOR TRUE POWER SOLAR 201 CLARK AVE POMONA, CA 91767 CSLB #: 970591/ B, C46 714-676-8888 9/13/2022 INITIAL PLAN SET -- ELECT. P.R. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: 970591/ B, C46 1/9/2023 CORRECTION 1 P.R. 5/11/2023 CORRECTION 3 P.R. SIGNAGE REQUIREMENTS GENERAL FIRE GUIDELINES & MARKING REQTS: SEC. 5. MARKINGS, LABELS, AND WARNING SIGNS. CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED CAUTION: SOLAR CIRCUIT PV 6 SIGNAGE COMBINER BOX/ CIRCUITS/ CONDUIT/ COMBINER BOX/ ENCLOSURES/ EMT ENCLOSURES1 1 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL 1 2 BUILDING / STRUCTURE2 CEC 705.10 - BY MAIN SERVICE PANEL: CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN. 201 E. LIVE OAK ARCADIA, CA 91006 WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION MAIN ELECTRIC SERVICE DISCONNECT SOLAR A/C DISCONNECT PV SOLAR ARRAY(S) SOLAR INVERTER D/C DISCONNECT DC DISCONNECT/ BREAKER/ RECOMBINER BOX3 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT PHOTOVOLTAIC DC DISCONNECT EMT/ DC CONDUIT RACEWAYS4 WARNING: PHOTOVOLTAIC POWER SOURCE INVERTER5 AC PHOTOVOLTAIC DISCONNECT OUTPUT CURRENT: OPERATING VOLTAGE: 240V PRODUCTION/ NET METER6 WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM AC DISCONNECT/ BREAKER/ POINTS OF CONNECTION7 PHOTOVOLTAIC AC DISCONNECT WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION 42A BREAKER PANEL/ PULL BOXES8 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL MAIN SERVICE DISCONNECT9 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN (690.56(C)(1)(a) YELLOW WITH BLACK LETTERING) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 10 BY RAPID SHUTDOWN SWITCH (WITHIN 3 FT)10 10 7 4 3 MAX SYSTEM VOLTAGE: MAX CIRCUIT CURRENT: MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED): POWER SOURCE OUTPUT PV INVERTER DC DISCONNECT 5 8 6 9 PV SYSTEM LABELING REQUIREMENTS NOT TO SCALE AC PHOTOVOLTAIC DISCONNECT OUTPUT CURRENT: OPERATING VOLTAGE:240V 42A 1 AC PHOTOVOLTAIC DISCONNECT OUTPUT CURRENT: OPERATING VOLTAGE: 240V 126A 600V 45A 18A 5 7 4 4 *RAPID SHUTDOWN SWITCH CAN BE EITHER THE AC DISCONNECT SWITCH OR A SEPARATE SWITCH. SEE PV 4 FOR TYPE OF RS SWITCH ARC FLASH AND SHOCK HAZARD APPROPRIATE PPE AND TOOLS REQUIRED WHILE WORKING ON THIS ENERGIZED EQUIPMENT. WARNING WARNING POWER SOURCE OUTPUT CONNECTION - DO NOT RELOCATE THIS OVERCURRENT DEVICE CEC 705.12(B)(2)(3)(b) CEC 690.13(B) CEC 690.13(B) CEC 690.13(B) CEC 690.31(G)(3) CEC 690.53 CEC 690.13(B) CEC 690.54 CEC 690.54 CEC 110.16 CEC 690.59, 705.12(D)(3) CEC 110.27(C) CEC 690.13(B) CEC 690.13(B) CEC 690.13(B) CEC 690.27(C) CEC 690.13(B) CEC 690.27(C) CEC 690.13(F), 705.12(B)(3-4) CEC 690.59, 705.12(B)(3-4) WARNING POWER SOURCE OUTPUT CONNECTION - DO NOT RELOCATE THIS OVERCURRENT DEVICE CEC 705.12(B)(2)(3)(b) I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF ARCADIA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF ARCADIA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: 201 E. LIVE OAK 201 E. LIVE OAK ARCADIA, CA 91006 NO.DATE DESCRIPTION STRUC. 1 CONTRACTOR TRUE POWER SOLAR 201 CLARK AVE POMONA, CA 91767 CSLB #: 970591/ B, C46 714-676-8888 9/13/2022 INITIAL PLAN SET -- ELECT. P.R. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: 970591/ B, C46 1/9/2023 CORRECTION 1 P.R. 5/11/2023 CORRECTION 3 P.R. PV 7 EQUIPMENT SPECIFICATIONS I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF ARCADIA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF ARCADIA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: 201 E. LIVE OAK 201 E. LIVE OAK ARCADIA, CA 91006 NO.DATE DESCRIPTION STRUC. 1 CONTRACTOR TRUE POWER SOLAR 201 CLARK AVE POMONA, CA 91767 CSLB #: 970591/ B, C46 714-676-8888 9/13/2022 INITIAL PLAN SET -- ELECT. P.R. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: 970591/ B, C46 1/9/2023 CORRECTION 1 P.R. 5/11/2023 CORRECTION 3 P.R. PV 8 UL LISTING