HomeMy WebLinkAbout35 W Huntington Dr - 2023 - Arcadia Self StorageEXISTING BUILDING ARCADIA SELF STORAGE 35 WEST HUNTINGTON DRIVE, ARCADIA, CA 91007 SPRINKLER MONITORING SYSTEM BUILDING INFORMATION SCOPE OF WORK ABBREVIATIONS SYMBOL LEGEND VICINITY MAP GENERAL NOTES DRAWINGS NOT PLOTTED 36" X 24" ARE NOT TO SCALE WIRE LEGEND EOL END-OF-LINE RESISTOR EX EXISTING DEVICE TO REMAIN SMP SPRINKLER MONITORING CONTROL PANEL FATC FIRE ALARM TERMINAL CABINET N NEW DEVICE FPLR FIRE-POWER LIMITED RISER THHN "T" THERMOPLASTIC INSULATED CABLE "HH" MEANS THAT THE WIRE IS HEAT RESISTANT AND CAN WITHSTAND A HIGHER TEMPERATURE (UP TO 194° F) "N" NYLON COATING THAT COVERS WIRE INSULATION PROJECT TEAM APPLICABLE CODES & REGULATIONS CENTRAL STATION INFORMATION 1.ALL WIRING SHALL BE INSTALLED IN ACCORDANCE WITH C.E.C. ARTICLE 760, POWER LIMITED FIRE PROTECTIVE SIGNALING CIRCUITS. 2.UPON COMPLETION OF THE INSTALLATION OF THE SPRINKLER MONITORING SYSTEM, A SATISFACTORY TEST WITHIN THE SCOPE OF WORK AS SHOWN ON THIS SUBMITTAL PACKAGE SHALL BE MADE IN THE PRESENCE OF THE FIRE MARSHAL. 3.A STAMPED SET OF APPROVED SPRINKLER MONITORING PLANS SHALL BE ON THE JOB SITE AND USED FOR INSTALLATION. ANY DEVIATION FROM APPROVED PLANS, INCLUDING THE SUBSTITUTION OF DEVICES, SHALL BE APPROVED BY THE FIRE MARSHAL. 4.ANY DISCREPANCIES BETWEEN THE DRAWINGS AND THE CODE OR RECOGNIZED STANDARDS SHALL BE BROUGHT TO THE ATTENTION OF THE INSPECTOR OF RECORD. 5.ALL DEVICES OF THE SPRINKLER MONITORING SYSTEM SHALL BE APPROVED AND LISTED BY THE CALIFORNIA STATE FIRE MARSHAL. 6.SPRINKLER MONITORING DEVICES SHALL BE INSTALLED PER N.F.P.A. 72. 7.ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANEL SHALL BE SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. 8.WIRING SHALL NOT BE LOOPED THROUGH DEVICES; WIRE MUST BE CUT AT EACH DEVICE. 9.ALL WIRING TO BE INSTALLED IN CONDUIT. CONDUIT SIZE TO BE 3/4" MINIMUM UNLESS OTHERWISE NOTED. 10.ALL CONDUCTORS ARE COPPER. 11.SYSTEM IS POWER LIMITED. 12.POINT AND COMMON ANNUNCIATION AND T-TAPPING PROHIBITED. 13.ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED TO MANUFACTURERS SPECIFICATIONS. 14.TO ENSURE THAT AUDIBLE PUBLIC MODE SIGNALS ARE CLEARLY HEARD, UNLESS OTHERWISE PERMITTED BY 18.4.3.2 THROUGH 18.4.3.5, THEY SHALL HAVE A SOUND LEVEL AT LEAST 15 dB ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 dB ABOVE THE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS, WHICHEVER IS GREATER, MEASURED 5 FT (1.5 m) ABOVE THE FLOOR IN THE AREA REQUIRED TO BE SERVED BY THE SYSTEM USING THE A-WEIGHTED SCALE (dBA) PER NFPA 72 SECTION 18.4.3.1. 15.AREAS HAVING MORE THAN TWO STROBES IN THE FIELD OF VIEW SHALL BE SYNCHRONIZED 2022 NFPA 72 18.5.5.7.2 16.SMOKE DETECTOR LOCATIONS ARE BASED ON SMOOTH CEILING WITH MAXIMUM HEIGHT OF 10 FEET UNLESS OTHERWISE NOTED. 17.STROBE LOCATION IS BASED ON 10 FOOT CEILING HEIGHT AND ARE INSTALLED ACCORDING TO NFPA 72 REQUIREMENTS UNLESS OTHERWISE NOTED. 18.POWER FOR THE SPRINKLER MONITORING CONTROL PANEL IS TO BE PROVIDED BY A DEDICATED CIRCUIT BREAKER. INDICATE LOCATION OF THIS BREAKER AT THE SMP. BREAKER TO BE RED AND LABELED "SPRINKLER MONITORING CONTROL DISCONNECT". 19.PROVIDE ELECTRICAL MONITORING FOR THE EXISTING INTERIOR CONTROL VALVES CONTROLLING THE WATER SUPPLY FOR THE SPRINKLER SYSTEMS. THIS INCLUDES, WATER FLOW AND TAMPER SWITCH. CONTROL VALVES FEEDING THE ON-SITE WATER SUPPLIES ARE ELECTRONICALLY MONITORED. WHERE AN AFFECTED WATER DISTRIBUTION TO THE BUILDING SHALL INDICATE A SUPERVISORY CONDITION WHEN A VALVE IS IN THE OFF-NORMAL POSITION. 20.SPRINKLER MONITORING CONDUCTORS USED IN WET OR UNDERGROUND LOCATIONS SHALL BE OF TYPE THWN. 21.THE RECORD OF COMPLETION DOCUMENTATION SHALL BE COMPLETED BY THE INSTALLING CONTRACTOR AND SUBMITTED TO THE CONCLUSION OF THE JOB. THE RECORD OF COMPLETION DOCUMENTATION SHALL BE PERMITTED TO BE PART OF THE WRITTEN STATEMENT REQUIRED IN 7.5.2 AND PART OF THE DOCUMENTS THAT SUPPORT THE REQUIREMENTS OF 7.5.8. WHEN MORE THAN ONE CONTRACTOR HAS BEEN RESPONSIBLE FOR THE INSTALLATION, EACH CONTRACTOR SHALL COMPLETE THE PORTIONS OF THE DOCUMENTATION FOR WHICH THAT CONTRACTOR HAS RESPONSIBILITY. 2022 NFPA 72 7.5.6.2. 22.SPRINKLER MONITORING SIGNAL SHALL MEET ANSI S3.41, AUDIBLE EMERGENCY EVACUATION SIGNAL (TEMPORAL PATTERN). 23.WITH EVERY NEW SYSTEM, A DOCUMENTATION CABINET SHALL BE INSTALLED AT THE SYSTEM CONTROL UNIT OR AT ANOTHER APPROVED LOCATION AT THE PROTECTED PREMISES. ALL RECORD DOCUMENTING SHALL BE STORED IN A DOCUMENTATION CABINET, PROVIDED BY OTHERS. WHERE THE DOCUMENTATION CABINET IS NOT IN THE SAME LOCATION AS THE SYSTEM CONTROL UNIT, ITS LOCATIONS SHALL BE IDENTIFIED AT THE SYSTEM CONTROL UNIT. THE DOCUMENTATION CABINET SHALL BE PROMINENTLY LABELED SYSTEM RECORD DOCUMENTS. THE CONTENTS OF THE CABINET SHALL BE ACCESSIBLE BY AUTHORIZED PERSONAL ONLY. 2022 NFPA 72 7.7.2.1-5 DOCUMENT ACCESSIBILITY. ALARM SERVICE COMPANY: (257057-001) ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST, CA 92630 PHONE: (855) 857-4888 UL NUMBER: S8126-1 * RECOMMENDATION FOR CONDUIT SIZE BY C.E.C MAXIMUM CONDUCTORS INCHES CONDUIT SIZE 3/4" #18 AWG 34 26 #16 AWG #14 AWG 24 BOX SIZE VS. NUMBER OF WIRES PER C.E.C. J-BOXES 4X4X2-1/2 #16 12 #14 10 CONDUIT WIRE FILL CHART V A SIGNAL CIRCUIT ADDRESSABLE CIRCUIT CALLOUT USAGE 2#18 FPLR (UNSHIELDED) TYPE 2#14 THHN (UNSHIELDED) TWISTED-PAIR, SOLID STRANDED AUXILIARY CIRCUITC 2#14 THHN (UNSHIELDED) (CONSTANT POWER)STRANDED #18 14 TYPE LETTERS CONDUCTORSIZE AWG/KCMIL 3/4 2214THHN 3/4" EMT CONDUIT 3/4" EMT CONDUIT WORST CASE SCENARIO FOR J. BOX AND CONDUIT DETAIL 3/4" EMT CONDUIT 36.40% (1) #14 THHN 0.111 IN. Ø CONDUIT WITH 2A,2R4" SQUARE ELECTRICAL BOX (2) #18 FPLR 0.158 IN. Ø MAXIMUM NUMBER OF CONDUCTORS IN ELECTRICAL METALLIC TUBING PERCENT AREA OF CONDUIT 3/4 0.824 0.533 0.213 TRADE SIZE INCHES INTERNAL DIAMETER INCHES TOTAL AREA 100% SQ.IN. OVER 2 WIRES 40% SQ.IN. AREA OF WORK PROJECT ADDRESS:35 W HUNTINGTON DRIVE ARCADIA, CA 91007 GROUP OCCUPANCY:B CONSTRUCTION TYPE:TYPE I-A FULLY SPRINKLERED: YES NUMBER OF FLOORS:2 AREA OF WORK:7,571 SQ. FEET 1.REMOVE THE EXISTING SPRINKLER MONITORING PANEL ON BASEMENT LEVEL. 2.INSTALLATION OF NEW STANDALONE EDWARD iO64R SPRINKLER MONITORING AND NEW ADDRESSABLE SMOKE DETECTOR ABOVE SPRINKLER MONITORING PANEL IN THE OFFICE AREA ON GROUND LEVEL. REFERENCE SHEET SM-401 FLOOR PLAN FOR THE EXACT LOCATION. 3.INSTALLATION OF NEW ADDRESSABLE MONITOR MODULES TO MONITOR WATERFLOW SWITCHES AND TAMPER SWITCHES ON BASEMENT LEVEL. REFERENCE SHEET SM-401 FLOOR PLANS FOR THE EXACT LOCATIONS. 4.INSTALLATION OF NEW VISUAL AND AUDIO-VISUAL TO PROVIDE PROPER COVERAGE IN THE AREA OF WORK PER NFPA72 REQUIREMENTS. REFERENCE SHEET SM-401 FLOOR PLAN FOR THE EXACT LOCATIONS. 5.INSTALLATION OF NEW TELGUARD TG-7FP WIRELESS COMMUNICATOR IN THE OFFICE AREA ON GROUND LEVEL. REFERENCE SHEET SM-401 FLOOR PLAN FOR THE EXACT LOCATION. 6.CONNECT ALL NEW VISUAL AND AUDIO-VISUAL NOTIFICATION APPLIANCE STROBE CIRCUITS TO THE NEW NAC POWER SUPPLY "V1" AND "V2" SIGNAL CIRCUITS. REFERENCE SHEET SM-401 FLOOR PLAN FOR EXACT LOCATIONS. SYMBOL QTY MANUFACTURER CATALOG #DESCRIPTION MOUNTING INFORMATION CSFM SMP# 1 EDWARDS iO64R SPRINKLER MONITORING CONTROL PANEL, 64 POINT CAPACITY, RED DOOR ENCLOSURE TO BE FURNISHED BY HCI; INSTALLED BY E.C.7165-1657:0244 1 EDWARDS SA-DACT DUAL LINE DIALER MOUNTS INSIDE FIRE ALARM CONTROL PANEL 7165-1657:0244 BATT 1 EDWARDS BC-1R BATTERY CABINET - BLACK BACKBOX, RED DOOR ENCLOSURE TO BE FURNISHED BY HCI; INSTALLED BY E.C N/A 2 INTERSTATE SLA1104 12 AMP-HOUR SEALED LEAD ACID BATTERY MOUNTS INSIDE BATTERY CABINET N/A FAC 1 TELGUARD TG-7FP 5G (LTE-M) SOLE PATH COMMUNICATOR FOR COMMERCIAL FIRE ENCLOSURE TO BE FURNISHED BY HCI; INSTALLED BY E.C.7300-1402:0502 S P 1 EDWARDS SIGA-OSD INTELLIGENT SMOKE DETECTOR MOUNTS TO DETECTOR BASE 7272-1657:0511 EDWARDS SIGA-SB4 DETECTOR BASE w/ TRIM SKIRT 2-1/4" DEEP 4" SQUARE ELECTRICAL BOX w/ 3-O RING 7300-1657:0120 DAIM 1 EDWARDS SIGA-CT2 DUAL MONITOR MODULE 2-1/4" DEEP 4" SQUARE BOX w/ SINGLE GANG RING 7300-1657:0121 SAIM 1 EDWARDS SIGA-CT1 SINGLE MONITOR MODULE 2-1/4" DEEP 4" SQUARE BOX w/ SINGLE GANG RING 7300-1657:0121 C 1 EDWARDS GCAVWF SELECTABLE CANDELA CEILING-MOUNTED LED HORN STROBE, WHITE MOUNTS TO GRSW-10 7125-1657:0515 1 EDWARDS GRSW-10 MOUNTING/WIRING PLATE (PACK OF 10)2-1/4" DEEP 4" SQUARE ELECTRICAL BOX 7320-1657:0516 --EXISTING FIRE ALARM BELL MONITORED BY HCI; FURNISHED & INSTALLED BY OTHERS N/A WF --EXISTING WATERFLOW SWITCH MONITORED BY HCI; FURNISHED & INSTALLED BY OTHERS N/A TS --EXISTING TAMPER SWITCH MONITORED BY HCI; FURNISHED & INSTALLED BY OTHERS N/A EOL -N/A END-OF-LINE RESISTOR N/A N/A CALIFORNIA CODE OF REGULATIONS (CCR), TITLE 19 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA FIRE CODE (CFC) -SECTION 903.4 FIRE SPRINKLER SUPERVISION AND MONITORING NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 72, 2022 EDITION OWNER: BEACONS STORAGE 35 W. HUNTINGTON DR. ARCADIA, CA 91007 CONTACT: PETER LEE PHONE: (310) 985-2133 EMAIL: peterintaelee@gmail.com FIRE ALARM CONTRACTOR: HCI SYSTEMS, INC 1354 SOUTH PARKSIDE PLACE ONTARIO,CA 91761 CONTACT: JOEL MONTES PHONE: (909) 628-7773 EMAIL: jmontes@hcisystems.net SEQUENCE OF OPERATION SMOKE DETECTOR SPRINKLER WATER FLOW SWITCH SPRINKLER TAMPER SWITCH SUPERVISORY BUILDING POWER FAILURE TG-7FP CELLULAR ALARM COMMUNICATOR ANNUNCIATE AT FIRE ALARM CONTROL PANEL IN FIRE CONTROL ROOM ALARM YES YES NO NO NO TROUBLE NO NO NO YES YES SUPERVISORY NO NO YES NO NO ANNUNCIATE AT 24HR. ATTENDED REMOTE LOCATION ALARM YES YES NO NO NO TROUBLE NO NO NO YES YES SUPERVISORY NO NO YES NO NO ANNUNCIATE AT REMOTE ANNUNCIATOR ALARM YES YES NO NO NO TROUBLE NO NO NO YES YES SUPERVISORY NO NO YES NO NO ACTIVATE AUDIBLE/VISUAL ALARM SIGNAL THROUGHOUT THE BUILDING YES YES NO NO NO DEVICE ACTION NOTIFICATION DEVICE LEGEND V1-1 DENOTES NOTIFICATION DEVICE NUMBER DENOTES NOTIFICATION CIRCUIT NUMBER DENOTES DEVICE TYPE DENOTES AUDIO/VISUAL (WALL-MOUNTED) DEVICE SYMBOL 15CD DENOTES CANDELA RATING V1 EOL END-OF-LINE RESISTOR DENOTES END-OF-LINE FOR CIRCUIT #V1 W - # - - - - - REVISION DATE - - 4-11797-1 A. ZABALA / USCADD 01/27/2024 K. REYES ARCADIA, CA 91007 35 W. HUNTINGTON DR. ARCADIA SELF-STORAGE SPRINKLER MONITORING SYSTEM C L T I LER F E F Y ET A S O FI H A I NIC. &OWL V GE I L C PS E A I S T S y s t e m s I n c. HCI Phone: (909) 628-7773 Fax: (909) 628-7774 24-Hour Service:(877) 331-2084 Website:www.hcisystems.net Corporate Office: 1354 S. Parkside Place Ontario, CA 91761 FIRE / LIFE SAFETY & LOW VOLTAGE SPECIALISTS ONTARIO SAN DIEGO IRVINE FRESNO PASADENA PLEASANTON SACRAMENTO COMPLETED DRAWINGS 01/29/24 FLOOR AND WALL PENETRATION, WIRING, TELGUARD TG-7FP, AND DEVICE WIRING DETAILS SPRINKLER MONITORING CONTROL PANEL (SMP1) & (NAC) BATTERY CALCULATIONS, AND RISER DIAGRAM #SHEET TITLESHT # DWG 1 SM-101 BUILDING INFORMATION, MAP, SCOPE OF WORK,NOTES, CODES, LEGENDS, AND ABBREVIATIONS 2 SM-201 3 4 SM-301 BASEMENT & GROUND LEVEL FLOOR PLAN SM-401 - - - - - BLDG. INFO., MAP, SCOPE OF WORK, NOTES, CODES, LEGENDS, AND ABBREVIATIONS NOT TO SCALE SM-101 SIDEWALL 12" MAXIMUM NOTE: MEASUREMENTS SHOWN ARE TO THE CLOSEST EDGE OF THE DETECTOR. (2016 NFPA72 A17.7.3.2.1) EXAMPLE PROPER MOUNTING FOR SMOKE DETECTORS MOUNTING HEIGHT DETAILS (CLASS B WIRING) LINE EARTH GROUND NEUTRAL L N TRANSFORMER TO SOLE PATH TELGUARD TG-7FP WIRELESS COMMUNICATOR SDACT WIRING DIALER CARD CONNECTION (J8) (CLASS B WIRING) 120VAC, 60Hz, 1.3A DEDICATED BRANCH CIRCUIT (PROVIDED BY E.C.) SCALE: NOT TO SCALE (CLASS B WIRING) LINE EARTH GROUND NEUTRAL L N TRANSFORMER TO SOLE PATH TELGUARD TG-7FP WIRELESS COMMUNICATOR SDACT WIRING DIALER CARD CONNECTION (J8) (CLASS B WIRING) 120VAC, 60Hz, 1.3A DEDICATED BRANCH CIRCUIT (PROVIDED BY E.C.) (CLASS B WIRING) LINE EARTH GROUND NEUTRAL L N TRANSFORMER TO SOLE PATH TELGUARD TG-7FP WIRELESS COMMUNICATOR SDACT WIRING DIALER CARD CONNECTION (J8) (CLASS B WIRING) 120VAC, 60Hz, 1.3A DEDICATED BRANCH CIRCUIT (PROVIDED BY E.C.) SMOKE DETECTOR (CLASS B WIRING) LINE EARTH GROUND NEUTRAL L N TRANSFORMER TO SOLE PATH TELGUARD TG-7FP WIRELESS COMMUNICATOR SDACT WIRING DIALER CARD CONNECTION (J8) (CLASS B WIRING) 120VAC, 60Hz, 1.3A DEDICATED BRANCH CIRCUIT (PROVIDED BY E.C.) LED 1 8 7 4 3 2 1 SINGLE INPUT MODULE CAT. NO. SIGA-CT1 REFER TO 387021 REV 2.0 FOR RATING AND INSTALLATION INFO. DATA IN (+) DATA IN (-) DATA OUT (+) DATA OUT (-) TO FACP DACT PRIMARY LINERJ-45 TO FACP AUXILIARY CIRCUIT (24VDC) TELGUARD TG-7FP TELGUARD TG-7FP (FAC) WIRING DETAIL SCALE: NOT TO SCALE TERM 1 4 3 2 5 7 6 DESCRIPTION DATA IN (-) DATA OUT (-) NOT USED NOT USED NOT USED NOT USED DATA IN/OUT (+) DATA OUT (-) DATA OUT (+) SIGA-SB4 DETECTOR BASE WIRING DETAIL: TO NEXT DEVICE REMOTE LED (SIGA-LED) -+ MAXIMUM RESISTANCE PER WIRE MUST NOT EXCEED 10Ω DATA IN (-) DATA IN (+) FROM SIGNATURE CONTROLLER OR PREVIOUS DEVICE MOUNTING DIAGRAM: SIGA-SB4 STANDARD DETECTOR BASE 4.186" 2.316" 4" SQUARE 1-1/2" DEEP ELECTRICAL BOX w/ 3 O RING BY E.C. SELF-LOCKING TAB LED INDICATOR TAMPER-RESIST LEVER ARM BREAK OFF TO DISABLE (LOCATED ON BASE) SIGA-TS 4" BOX TRIM SKIRT/RING GC SERIES CEILING MOUNT LED STROBE OR HORN STROBE (-)OR FROM FACP/SAP/ (+) (-) (+)TO NEXT NOTIFICATION DEVICE OR EOL RESISTOR REMOTE POWER SUPPLY FROM PRVIOUS NOTIFICATION DEVICE DEVICE WIRING DETAILS FOR SERVICE CALL: 877-331-2084 HCI SYSTEMS, INC. +-+- SLA1105 12 VDC BATTERY, 12 A.H. SLA1105 12 VDC BATTERY, 12 A.H. FOR SERVICE CALL: 877-331-2084HCI SYSTEMS, INC. (CLASS B WIRING) LINE EARTH GROUND NEUTRAL L N TRANSFORMER TO SOLE PATH TELGUARD TG-7FP WIRELESS COMMUNICATOR SDACT WIRING DIALER CARD CONNECTION (J8) (CLASS B WIRING) 120VAC, 60Hz, 1.3A DEDICATED BRANCH CIRCUIT (PROVIDED BY E.C.) (CLASS B WIRING) LINE EARTH GROUND NEUTRAL L N TRANSFORMER TO SOLE PATH TELGUARD TG-7FP WIRELESS COMMUNICATOR SDACT WIRING DIALER CARD CONNECTION (J8) (CLASS B WIRING) 120VAC, 60Hz, 1.3A DEDICATED BRANCH CIRCUIT (PROVIDED BY E.C.) (CLASS B WIRING) LINE EARTH GROUND NEUTRAL L N TRANSFORMER TO SOLE PATH TELGUARD TG-7FP WIRELESS COMMUNICATOR SDACT WIRING DIALER CARD CONNECTION (J8) (CLASS B WIRING) 120VAC, 60Hz, 1.3A DEDICATED BRANCH CIRCUIT (PROVIDED BY E.C.) CEILING ACCEPTABLE TOP OF DETECTOR ACCEPTABLE HERE SPRINKLER MONITORING CONTROL PANEL (SMP1) DETAILS CEILING MOUNTED ABOVE FINISHED FLOOR 72" MAX 60" MIN. iO64R FIRE ALARM CONTROL PANEL (CLASS B WIRING) LINE EARTH GROUND NEUTRAL L N TRANSFORMER TO SOLE PATH TELGUARD TG-7FP WIRELESS COMMUNICATOR SDACT WIRING DIALER CARD CONNECTION (J8) (CLASS B WIRING) 120VAC, 60Hz, 1.3A DEDICATED BRANCH CIRCUIT (PROVIDED BY E.C.) LED 1 8 7 4 3 2 1 SINGLE INPUT MODULE CAT. NO. SIGA-CT1 REFER TO 387021 REV 2.0 FOR RATING AND INSTALLATION INFO. DATA IN (+) DATA IN (-) DATA OUT (+) DATA OUT (-) TO FACP DACT PRIMARY LINERJ-45 TO FACP AUXILIARY CIRCUIT (24VDC) TELGUARD TG-7FP TERM 1 4 3 2 5 7 6 DESCRIPTION DATA IN (-) DATA OUT (-) NOT USED NOT USED NOT USED NOT USED DATA IN/OUT (+) DATA OUT (-) DATA OUT (+) SIGA-SB4 DETECTOR BASE WIRING DETAIL: TO NEXT DEVICE REMOTE LED (SIGA-LED) -+ MAXIMUM RESISTANCE PER WIRE MUST NOT EXCEED 10Ω DATA IN (-) DATA IN (+) FROM SIGNATURE CONTROLLER OR PREVIOUS DEVICE SIGA-SB4 STANDARD DETECTOR BASE 4.186" 2.316" 4" SQUARE 1-1/2" DEEP ELECTRICAL BOX w/ 3 O RING BY E.C. SELF-LOCKING TAB LED INDICATOR TAMPER-RESIST LEVER ARM BREAK OFF TO DISABLE (LOCATED ON BASE) SIGA-TS 4" BOX TRIM SKIRT/RING GC SERIES CEILING MOUNT LED STROBE OR HORN STROBE WIRING AND MOUNTING DETAIL: (-)OR FROM FACP/SAP/ (+) (-) (+)TO NEXT NOTIFICATION DEVICE OR EOL RESISTOR REMOTE POWER SUPPLY FROM PRVIOUS NOTIFICATION DEVICE FOR SERVICE CALL: 877-331-2084 HCI SYSTEMS, INC. +-+- SLA1105 12 VDC BATTERY, 12 A.H. SLA1105 12 VDC BATTERY, 12 A.H. FOR SERVICE CALL: 877-331-2084HCI SYSTEMS, INC. ELECTRICAL BOX TRIM PLATE (OPTIONAL) WIRING PLATE MACHINE SCREW (2X) DEVICE COVER ELECTRICAL BOX TRIM PLATE (OPTIONAL) WIRING PLATE MACHINE SCREW (2X) DEVICE COVER 8 7 6 4 3 2 1 DUAL INPUT MODULE CAT. NO. SIGA-CT2 REFER TO 387037 REV 2.0 FOR RATING AND INSTALLATION INFO. DATA IN (+) DATA IN (-) DATA OUT (+) DATA OUT (-) 5 CONTACT STATUS/ALARM EOLR 47K STATUS/ALARM CONTACT EOLR 47K DUAL INPUT MODULE 8 7 4 3 2 1 SINGLE INPUT MODULE CAT. NO. SIGA-CT1 REFER TO 387021 REV 2.0 FOR RATING AND INSTALLATION INFO. DATA IN (+) DATA IN (-) DATA OUT (+) DATA OUT (-) CONTACT STATUS/ALARM EOLR 47K SINGLE INPUT MODULE SIGA-CT1 SIGA-CT2 8 7 6 4 3 2 1 DUAL INPUT MODULE CAT. NO. SIGA-CT2 REFER TO 387037 REV 2.0 FOR RATING AND INSTALLATION INFO. DATA IN (+) DATA IN (-) DATA OUT (+) DATA OUT (-) 5 CONTACT STATUS/ALARM EOLR 47K STATUS/ALARM CONTACT EOLR 47K DUAL INPUT MODULE 8 7 4 3 2 1 SINGLE INPUT MODULE CAT. NO. SIGA-CT1 REFER TO 387021 REV 2.0 FOR RATING AND INSTALLATION INFO. DATA IN (+) DATA IN (-) DATA OUT (+) DATA OUT (-) CONTACT STATUS/ALARM EOLR 47K SINGLE INPUT MODULE SIGA-CT1 SIGA-CT2 SCALE: NOT TO SCALE SCALE: NOT TO SCALE CEILING LINE - # - - - - - REVISION DATE - - 4-11797-1 A. ZABALA / USCADD 01/27/2024 K. REYES ARCADIA, CA 91007 35 W. HUNTINGTON DR. ARCADIA SELF-STORAGE SPRINKLER MONITORING SYSTEM C L T I LER F E F Y ET A S O FI H A I NIC. &OWL V GE I L C PS E A I S T S y s t e m s I n c. HCI Phone: (909) 628-7773 Fax: (909) 628-7774 24-Hour Service:(877) 331-2084 Website:www.hcisystems.net Corporate Office: 1354 S. Parkside Place Ontario, CA 91761 FIRE / LIFE SAFETY & LOW VOLTAGE SPECIALISTS ONTARIO SAN DIEGO IRVINE FRESNO PASADENA PLEASANTON SACRAMENTO COMPLETED DRAWINGS 01/29/24 FLOOR AND WALL PENETRATION, WIRING, TELGUARD TG-7FP, AND DEVICE WIRING DETAILS SPRINKLER MONITORING CONTROL PANEL (SMP1) & (NAC) BATTERYCALCULATIONS, AND RISER DIAGRAM #SHEET TITLESHT # DWG 1 SM-101 BUILDING INFORMATION, MAP, SCOPE OF WORK,NOTES, CODES, LEGENDS, AND ABBREVIATIONS 2 SM-201 3 4 SM-301 BASEMENT & GROUND LEVEL FLOOR PLAN SM-401 - - - - - FLOOR & WALL PENETRATION, WIRING, TELGUARD TG-7FP, AND REMOTE ANNUNCIATOR DETAILS NOT TO SCALE SM-201 NAC POWER SUPPLY BATTERY AND VOLTAGE DROP CALCULATIONS SPRINKLER MONITORING CONTROL PANEL (SMP1) BATTERY CALCULATIONS RISER DIAGRAM VOLTAGE DROP CALCULATION: COATED (OHM/kFT) WIRE SIZE (AWG) 3.26 14 2.05 12 5.29 16 8.41 18 FEET = One way distance in feet measured VOLTAGE DROP FOR A GIVEN AMP = Amperes per terminal of load WHERE: = AMP x FEET x 3.26 x 2 1000 OPERATING VOLTAGE = SYSTEM VOLTAGE (20.4) LENGTH OF CONDUCTOR from source of supply to load FORMULA: - VOLTAGE DROP FAC N S N P AIM S N BASEMENT LEVEL 1A,1C,1V 1A,1C 1A,1C 120VAC DEDICATED CIRCUIT BY E.C. C 75CD V1-1 N 1V 1A GROUND LEVEL EOL V1 AIM D VS EX WFEX1C 1C 1A SMP N1 Appendix B: Worksheets iO64 and iO1000 Technical Reference Manual 235 Worksheet A: Control panel current loadDevicesQtyStandbycurrent (mA)Alarmcurrent (mA)Qty xStandbycurrent (mA)Qty x Alarmcurrent (mA)Base panel1See note [1]belowSee note [2]belowFirst loop on 1stSLC card(fully loaded loop)5580Second loop on1st SLC card(fully loaded loop)4570First loop on 2ndSLC card(fully loaded loop)5580Second loop on2nd SLC card(fully loaded loop)4570SA-CLA Class Acard360SA-232 RS-232card1313SA-DACT dialer4141SA-ETH networkcard3434LED expander41 expander:482 expanders:96Totals (mA)(transfer totals to BatteryCalculation Worksheet)[1]iO64: 155iO1000: 172[2]iO64: 204iO1000: 267 - # - - - - - REVISION DATE - - 4-11797-1 A. ZABALA / USCADD 01/27/2024 K. REYES ARCADIA, CA 91007 35 W. HUNTINGTON DR. ARCADIA SELF-STORAGE SPRINKLER MONITORING SYSTEM C L T I LER F E F Y ET A S O FI H A I NIC. &OWL V GE I L C PS E A I S T S y s t e m s I n c. HCI Phone: (909) 628-7773 Fax: (909) 628-7774 24-Hour Service:(877) 331-2084 Website:www.hcisystems.net Corporate Office: 1354 S. Parkside Place Ontario, CA 91761 FIRE / LIFE SAFETY & LOW VOLTAGE SPECIALISTS ONTARIO SAN DIEGO IRVINE FRESNO PASADENA PLEASANTON SACRAMENTO COMPLETED DRAWINGS 01/29/24 FLOOR AND WALL PENETRATION, WIRING, TELGUARD TG-7FP, AND DEVICE WIRING DETAILS SPRINKLER MONITORING CONTROL PANEL (SMP1) & (NAC) BATTERYCALCULATIONS, AND RISER DIAGRAM #SHEET TITLESHT # DWG 1 SM-101 BUILDING INFORMATION, MAP, SCOPE OF WORK,NOTES, CODES, LEGENDS, AND ABBREVIATIONS 2 SM-201 3 4 SM-301 BASEMENT & GROUND LEVEL FLOOR PLAN SM-401 - - - - - SPRINKLER MONITORING CONTROL PANEL (SMP1) & NAC BATTERY CALCS, AND RISER DIAGRAM NOT TO SCALE SM-301 ENLARGED BASEMENT LEVEL FLOOR PLAN S N P EXISTING SPRINKLER BELL EX SYMBOL LEGEND WIRE LEGEND 75CD V1-1 NEOL V1 1A 1A AIMS N WF EX VS EX AIM N D TO MONITOR TELGUARD TG-7FP 120VAC DEDICATED CIRCUIT BY E.C. DOWN TO LOWER LEVEL UP TO UPPER LEVEL 1A SCALE: NOT TO SCALE FA C N 1A,1C V A SIGNAL CIRCUIT ADDRESSABLE CIRCUIT CALLOUT USAGE 2#18 FPLR (UNSHIELDED) TYPE 2#14 THHN (UNSHIELDED) TWISTED-PAIR, SOLID STRANDED AUXILIARY CIRCUITC 2#14 THHN (UNSHIELDED) (CONSTANT POWER)STRANDED SYMBOL DESCRIPTION SMP N#SPRINKLER MONITORING CONTROL PANEL, 64 POINT CAPACITY, RED DOOR FAC N 5G (LTE-M) SOLE PATH COMMUNICATOR FOR COMMERCIAL FIRE S N P INTELLIGENT SMOKE DETECTOR AIM N D DUAL MONITOR MODULE AIM S N SINGLE MONITOR MODULE C N SELECTABLE CANDELA CEILING-MOUNTED LED HORN STROBE, WHITE EX EXISTING SPRINKLER BELL WF EX EXISTING WATERFLOW SWITCH VS EX EXISTING TAMPER SWITCH EOL END-OF-LINE RESISTOR SCALE: NOT TO SCALE ENLARGED GROUND LEVEL FLOOR PLAN 1V 1A,1V SEE ENLARGED FLOOR PLAN BASEMENT LEVEL FLOOR PLAN SCALE: 1/8" = 1' - 0" SCALE: 1/8" = 1' - 0"GROUND LEVEL FLOOR PLAN SM P N1 C BASEMENT & GROUND LEVEL FLOOR PLAN NOT TO SCALE SM-401 - # - - - - - REVISION DATE - - 4-11797-1 A. ZABALA / USCADD 01/27/2024 K. REYES ARCADIA, CA 91007 35 W. HUNTINGTON DR. ARCADIA SELF-STORAGE SPRINKLER MONITORING SYSTEM C L T I LER F E F Y ET A S O FI H A I NIC. &OWL V GE I L C PS E A I S T S y s t e m s I n c. HCI Phone: (909) 628-7773 Fax: (909) 628-7774 24-Hour Service:(877) 331-2084 Website:www.hcisystems.net Corporate Office: 1354 S. Parkside Place Ontario, CA 91761 FIRE / LIFE SAFETY & LOW VOLTAGE SPECIALISTS ONTARIO SAN DIEGO IRVINE FRESNO PASADENA PLEASANTON SACRAMENTO COMPLETED DRAWINGS 01/29/24 FLOOR AND WALL PENETRATION, WIRING, TELGUARD TG-7FP, AND DEVICE WIRING DETAILS SPRINKLER MONITORING CONTROL PANEL (SMP1) & (NAC) BATTERYCALCULATIONS, AND RISER DIAGRAM #SHEET TITLESHT # DWG 1 SM-101 BUILDING INFORMATION, MAP, SCOPE OF WORK,NOTES, CODES, LEGENDS, AND ABBREVIATIONS 2 SM-201 3 4 SM-301 BASEMENT & GROUND LEVEL FLOOR PLAN SM-401 - - - - -