HomeMy WebLinkAbout142 La Porte St - 2024 -142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
DATE NO. DESCRIPTION
DRAWN BY:
DRAWING TITLE
SCALE:
SHEET NO.
REVISION
ACRC
AS SHOWN
unless they are sealed, signed and dated
not final and ready for use, and therefore not valid
As instruments of service, these documents are
of acceptance of these restrictions.
or specifications shall constitute conclusive evidence
of the Architect. Visual contact with these drawings
have been prepared, without the written consent
other than the specific project for which they
shall be reproduced or used for any purpose
property of the Architect and no part thereof
and arrangements represented thereby are the
These drawings, specifications, ideas, designs
5120 HAMNER AVE
# 140
EASTVALE, CA 91752
951.454.8801
PROJECT
DATE: FEB. 08, 2023
PLAN CHECK NO.
A
R
C
ESIGN
www.acrcdesigns.com
P.C. CORRECTION12/27/23
P.C. CORRECTION28/25/23
P.C. CORRECTION32/25/24
PROJECT DATA
AND
SITE PLAN
A0.1
8,000 SQ. FT.
PROJECT DESCRIPTION:
PROJECT ADDRESS:
GROSS LOT AREA:
142 LA PORTE STREET, ARCADIA, CA. 91006
5773-004-015ASSESSOR'S ID NO:
ZONING:
TOPOGRAPHY:RELATIVELY FLAT
TOTAL BUILDING COVERAGE: 3,920 SQ. FT.
LANDSCAPED AREA:910 SQ. FT. (11.3%)
(49.0%)
SITE MATRIX INFO:
HARDSCAPED AREA / DRIVEWAY:3,170 SQ. FT. (39.7%)
TOTAL LOT AREA:8,000 SQ. FT. (100.0%)
TYPE OF CONSTRUCTION:
OCCUPANCY TYPE:
MAX. FLOOR AREA RATIO:
8,000 SQ. FT. x 0.5 =
VB - WITH FULLY FIRE-SPRINKLERED SYSTEM
MAX. BUILDING HEIGHT / STORY:40'-0" / 3 STORIES
4,000 SQ. FT.
PROPOSED FLOOR AREA:
TOTAL FLOOR AREA = 3,920 SQ. FT.
PROPOSED BUILDING HEIGHT / STORY:29'-6" / 1 STORY
"S1" - WAREHOUSE AREA
PROPOSED A 3,980 S.F. - ONE STORY
LIGHT INDUSTRIAL / WAREHOUSE BUILDING
CM - COMMERCIAL MANUFACTURING
PARKING SPACE REQUIRED:
PARKING SPACE PROVIDED:
9'-0" x 18'-0" (STD.)= 3 SPACES
TOTAL PROVIDED = 4 SPACES
9'-0" x 18'-0" = 1 SPACES
(ADA VAN ACCESSIBLE)
3,400 S.F. / 1,000 = 3.4WAREHOUSE AREA
4.2
WAREHOUSE AREA 1,202 SQ. FT.
UNIT 'A'
UNIT 'A' TOTAL FLOOR AREA 1,372 SQ. FT.
WAREHOUSE AREA 1,099 SQ. FT.
UNIT 'B'
WAREHOUSE AREA 1,099 SQ. FT.
UNIT 'C'
GROUND LEVEL TOTAL 1,274 SQ. FT.
OFFICE AREA 100 SQ. FT.
OFFICE AREA 95 SQ. FT.
OFFICE AREA 95 SQ. FT.
290 S.F. / 350 = 0.8OFFICE AREA
RESTROOM 70 SQ. FT.
RESTROOM 80 SQ. FT.
UNIT 'B' TOTAL FLOOR AREA 1,274 SQ. FT.
RESTROOM 80 SQ. FT.
ALL CONSTRUCTION AND DETAILS SHALL BE COMPLETED IN FULL
COMPLIANCE WITH THE LOCAL ORDNANCES AND ALL OTHER
f. NFPA 13 FIRE SPRINKLER SYSTEM
j. NFPA 72 FIRE ALARM / SPRINKLER MONITORING SYSTEM
k. SECURITY ALARM SYSTEM
2019 CALIFORNIA BUILDING CODE - TITLE 24, PART 2
2019 CALIFORNIA ELECTRICAL CODE - TITLE 24, PART 3
2019 CALIFORNIA MECHANICAL CODE - TITLE 24, PART 4
2019 CALIFORNIA PLUMBING CODE - TITLE 24, PART 5
2019 CALIFORNIA ENERGY CODE - TITLE 24, PART 6
2019 CALIFORNIA GREEN BUILDING STANDARDS CODE
APPLICABLE CODES AND REQUIREMENTS.
DEFERRED APPROVAL
- TITLE 24, PART 11
g. NFPA 13 FIRE SPRINKLER UNDERGROUND SYSTEM
h. NFPA 14 FIRE STANPIPE
FIRE DEPARTMENT NOTES:
1) THE BUILDING SHALL BE FULLY FIRE SPRINKLERED PER THE CITY OF
CENTRAL STATION. NOTIFICATION APPLIANCES SHALL BE PROVIDED
ARCADIA FIRE DEPARTMENT COMMERCIAL SPRINKLER STANDARD.
2) THE FIRE SPRINKLER SYSTEM SHALL BE MONITORED BY A UL LISTED
IN ALL COMMON AREAS.
CIVIL OR MECHANICAL ENGINEER TO DETERMINE THE MAXIMUM
2) THE APPLICANT/PROPERTY OWNER SHALL PROVIDE SEPARATE
3) A REDUCED PRESSURE BACKFLOW DEVICE SHALL BE INSTALLED AS
4) FIRE PROTECTION REQUIREMENTS SHALL BE AS STIPULATED BY THE
6) NEW WATER SERVICE INSTALLATIONS SHALL BE BY THE APPLICANT/
PORTE STREET AND SAINT JOSEPH ST. ASSUMING TYPICAL SANITARY
8) THE APPLICANT/PROPERTY OWNER SHALL UTILIZE EXISTING SEWER
MANHOLE COVER (503.49’ ON THE ALLEY BETWEEN LA PORTE ST.
10) THE EXISTING CITY TREE ON THE CITY PARKWAY SHALL REMAIN.
11) THE TRASH ENCLOSURE SHALL ACCOMMODATE WASTE, RECYCLING
OWNER SHALL PROVIDE CALCULATIONS PREPARED BY A LICENSED
DOMESTIC WATER AND/OR FIRE SERVICES. THE APPLICANT/PROPERTY
BETWEEN LA PORTE ST. AND SAINT JOSEPH ST IS AVAILABLE FOR
1) A 4” STEEL WATER MAIN WITH 45 PSI STATIC PRESSURE IN THE ALLEY
DOMESTIC DEMAND AND MAXIMUM FIRE DEMAND IN ORDER TO
VERIFY THE REQUIRED WATER SERVICE SIZE.
WATER SERVICES AND METERS FOR COMMERCIAL AND IRRIGATION
USES.
METER SERVICES PROTECTION FOR COMMERCIAL USES.
ARCADIA FIRE DEPARTMENT AND SHALL BE CONFORMED TO ARCADIA
STANDARD PLAN. ALL FIRE SERVICES SHALL BE ISOLATED FROM
DOMESTIC WATER SERVICES WITH APPROVED BACK FLOW
PREVENTION DEVICES.
5) A WATER METER PERMIT APPLICATION SHALL BE SUBMITTED TO THE
PUBLIC WORKS SERVICES DEPARTMENT PRIOR TO PERMIT ISSUANCE.
PROPERTY OWNER. INSTALLATION SHALL BE ACCORDING TO THE
SPECIFICATIONS OF THE PUBLIC WORKS SERVICES DEPARTMENT,
ENGINEERING SECTION. ABANDONMENT OF EXISTING WATER SERVICES,
IF NECESSARY, SHALL BE CARRIED OUT BY THE DEVELOPER,
ACCORDING TO PUBLIC WORKS SERVICES DEPARTMENT, ENGINEERING
DIVISION SPECIFICATIONS.
7) AN 8” VCP CITY SEWER MAIN IS AVAILABLE IN THE ALLEY BETWEEN
SEWER DEMANDS FOR A PROJECT OF THIS SIZE AND TYPE, THE EXISTING
8” CITY SEWER SHOULD BE CAPABLE OF MEETING ALL ANTICIPATED
DEMANDS OF THE IMPROVEMENTS AS DESCRIBED IN THE INFORMATION
PROVIDED.
LATERAL IF POSSIBLE.
9) AN APPROVED BACKWATER VALVE IS REQUIRED TO BE INSTALLED
ON THE LATERAL BEHIND THE PROPERTY LINE IF ANY DRAINAGE FIXTURE
ELEVATION IS LOWER THAN THE ELEVATION OF THE NEXT UPSTREAM
AND SAINT JOSEPH ST.).
WASTE, AND GREEN WASTE PER THE REQUIREMENTS OF THE DESIGNATED
WASTE MANAGEMENT COMPANY. THE TRASH ENCLOSURE SHALL
REQUIRE A COVER AND A MINIMUM ONE-FOOT CLEARANCE SHALL BE
PROVIDED AROUND EACH BIN/CART. DIMENSIONAL ELEVATIONS OF THE
TRASH ENCLOSURE IS REQUIRED.
PUBLIC WORKS DEPARTMENT NOTES:
PROPERTY LINE.
LINE TO PROPERTY LINE ALONG THE ALLEY FRONTAGE.
APPROACH PER CITY STANDARD PLAN.
4) THE APPLICANT/PROPERTY OWNER SHALL REPAIR ANY DAMAGES
EXISTING CURB, GUTTER AND SIDEWALK FROM PROPERTY LINE TO
1) THE APPLICANT/PROPERTY OWNER SHALL REMOVE AND REPLACE
THE ASPHALT ALLEY AND CONCRETE RIBBON GUTTER FROM PROPERTY
2) THE APPLICANT/PROPERTY OWNER SHALL REMOVE AND REPLACE
3) THE APPLICANT/PROPERTY OWNER SHALL INSTALL NEW DRIVE
CAUSED BY THE DEVELOPMENT TO THE ASPHALT STREET FRONTAGE
FROM PROPERTY LINE TO PROPERTY LINE INCLUDING BUT NOT LIMITED
TO TRENCH CUTS AND CONSTRUCTION TRAFFIC, PER THE DIRECTION
OF THE CITY ENGINEER.
ENGINEERING DEPARTMENT NOTES:
TOTAL
3.2TOTAL PARKING REQUIRED
(25% PARKING REDUCTION: 4.2x25%=1.0)
PROJECT DATAVICINITY MAP
PROJECT SITE
GOVERNING CODES
SHEET INDEX
CONTRACTORS/SUBCONTRACTORS SHALL SUBMIT SEPARATE
APPLICATION(S) AND SECURE SEPARATE PERMIT(S) FOR:
a. ELECTRICAL WORK
b. MECHANICAL WORK
c. PLUMBING WORK
d. DEMOLITION
e. BLOCK WALLS EXCEEDING 6 FEET IN HEIGHT
A0.3 GREEN BUILDING STANDARDS CODE - SHEET 1
A0.1 PROJECT DATA AND GENERAL NOTES
OWNER ARCHITECTURAL DESIGNER
CONTACT: HENRY CHEN (951)454.8801
EASTVALE, CA. 91752
5120 HAMNER AVE., #140
ACRC DESIGN GROUP
PROJECT TEAM
PHONE: (415)531.0055
SAN MARINO, CA. 91108
2735 DORESTA ROAD
MR. DREW HAW
PROJECT MANAGER
STRUCTURAL ENGINEER
PHONE: (626) 658-7974
ARCADIA, CA. 91006
333 N. SANTA ANITA AVE., #3
WPH ENGINEERING LLC.
MECH., PLUMBING & ELECT. ENGINEER
SAN GABRIEL, CA. 91775
1217 E. LAS TUNAS DRIVE
TRICOLOR ENGINEERING
CONTACT: YONGHUI CHEN
PHONE: (626) 692.1221
INSURANCE CERTIFICATE. ALL WORK SHALL CONFORM TO ALL REQUIREMENTS OF STATE OF
THE WORK IS DONE IN ACCORDANCE WITH CODE REQUIREMENTS PRIOR TO REQUESTING INSPECTION.
EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR ANY OTHER DRAINAGE
DISPOSED OF AS SOLID WASTE.
SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY VEHICLE TRAFFIC.
THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE STABILIZED SO AS TO INHIBIT SEDIMENTS
FROM BEING DEPOSITED INTO THE PUBLIC WAY. ACCIDENTAL DEPOSITIONS MUST BE SWEPT UP
STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED MATERIALS MUST BE PROTECTED
TRASH AND CONSTRUCTION RELATED SOLID WASTES MUST BE DEPOSITED INTO A COVERED
FUELS, OILS, SOLVENTS AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE WITH
STORAGE CONTAINERS ARE TO BE PROTECTED FROM THE WEATHER. SPILLS MUST BE CLEANED UP
IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED INTO THE
DRAINAGE SYSTEM.
SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) SHALL BE NOTIFIED IN ACCORDANCE
WORK. THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT OFFICE IS LOCATED AT
A 10 DAY WAIT PERIOD PRIOR TO START OF WORK.
ALL NONCOMPLIANT PLUMBING FIXTURES SHALL BE REPLACED WITH WATER-CONSERVING
DUE TO THE POSSIBLE PRESENCE OF LEAD-BASED PAINT, LEAD-SAFE WORK PRACTICES ARE
17920.10 AND 105256 WITH POTENTIAL FINES FOR VIOLATIONS UP TO $5,000 (SECTION (D) AMENDED)
OR IMPRISONMENT FOR NOT MORE THAN 6 MONTHS IN THE COUNTY JAIL OR BOTH.
THE ISSUANCE OF A PERMIT SHALL NOT PREVENT THE BUILDING OFFICIAL FROM REQUIRING
CODES ADOPTED BY THE CITY, RELEVANT LAWS, ORDINANCES, RULES AND/OR REGULATIONS.
SEPARATE PERMIT SHALL FIRST BE OBTAINED FROM THE CITY PUBLIC WORKS DEPARTMENT
SEPARATE PERMIT(S) ARE REQUIRED FOR DEMOLITION OF ALL STRUCTURES ON THE SITE.
AT TIME OF PERMIT ISSUANCE, CONTRACTOR SHALL SHOW THEIR VALID WORKERS' COMPENSATION 1.
IT IS THE RESPONSIBILITY OF THE INDIVIDUAL SUPERVISING THE CONSTRUCTION TO ENSURE THAT
CALIFORNIA TITLE 24 REGARDLESS OF THE INFORMATION INDICATED ON THESE PLANS.
SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTES ON SITE UNTIL THEY CAN BE
AND MAY NOT BE WASHED DOWN BY RAIN OR OTHER MEANS.
FROM BEING TRANSPORTED FROM THE SITE BY THE FORCES OF WIND OR WATER.
RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND DISPERSAL BY WIND.
THEIR LISTING AND ARE NOT TO CONTAMINATE THE SOIL AND SURFACE WATERS. ALL APPROVED
2.
WITH CALIFORNIA STATE LAW PRIOR TO START OF ANY DEMOLITION, ADDITION, AND/OR REMODEL
21865 COPLEY DRIVE IN DIAMOND BAR, PHONE NO (909)396-2000 BE ADVISED, SCAQMD MAY REQUIRE
3.
PLUMBING FIXTURE PRIOR TO FINAL INSPECTION.
4.
REQUIRED FOR ALL REPAIRS THAT DISTURB PAINT IN PRE-1979 BUILDINGS. FAILURE TO DO SO
COULD CREATE LEAD HAZARDS THAT VIOLATE CALIFORNIA HEALTH & SAFETY CODE, SECTIONS
5.
THE CORRECTION OF ERRORS ON THESE PLANS OR FROM PREVENTING ANY VIOLATION OF THE
6.
PRIOR TO PLACEMENT OF ANY CONSTRUCTION MATERIALS OR EQUIPMENT IN THE PUBLIC WAY.
7.
GENERAL NOTES
HENRYHANCHEN@GMAIL.COM
WPH@WPHENGINEERING.COM
A0.2 CONDITIONS OF APPROVAL
LANDSCAPE ARCHITECT
PHONE: (626) 780-2020
MONROVIA, CA
422 PARK ROSE AVE.
ED SIRIBOHDI
ASIRIBOHDI@GMAIL.COM
CIVIL ENGINEER
CONTACT: MAR DEO DE OCAMPO
LOS ALAMITOS, CA. 90720
5122 KATELLA AVE., SUITE 210
ZENITH ENGINEERING & SURVEYING, INC.
(714) 576-7725
INFO@ZENITHCELS.COM
GEOTECHNICAL ENGINEERING
PHONE: (818) 341-1899
CHATSWORTH, CA. 91311
9428 ETON AVE., UNIT M
C.Y. GEOTECH, INC.
CYGEOTECH@SBCGLOBAL.NET
A0.4 GREEN BUILDING STANDARDS CODE - SHEET 2
A0.5 GREEN BUILDING STANDARDS CODE - SHEET 3
A1.1 PROJECT DATA AND SITE PLAN
A1.2 ADA STANDARDS
A2.1 FLOOR PLAN
A2.2 REFLECTED CEILING PLAN
A3 ROOF PLAN
A4.1 EXTERIOR ELEVATIONS
A4.2 EXTERIOR ELEVATIONS
A5 BUILDING SECTIONS
A6.1 DOOR AND WINDOW SCHEDULES
A7.1 ARCHITECTURAL DETAILS
S0.1 STRUCTURAL GENERAL NOTES
S1.0 FOUNDATION PLAN
S2.0 LINTEL / HEADER FRAMING +PLAN
S3.0 ROOF FRAMING PLAN
SD1 STRUCTURAL DETAILS
SD2 STRUCTURAL DETAILS
SD3 STRUCTURAL DETAILS
SD4 STRUCTURAL DETAILS
M1.0 MECHANICAL GENERAL NOTES AND SYMBOL
M1.1 MECHANICAL SCHEDULES
M1.2 MECHANICAL DETAILS
M2.0 MECHANICAL FLOOR PLAN
M2.1 MECHANICAL ROOF PLAN
M3.1 ENERGY REPORT
M3.2 ENERGY REPORT
P0.1 PLUMBING GENERAL NOTES AND SYMBOL
P0.2 PLUMBING SCHEDULES
P1.1 PLUMBING PLAN - COLD & HOT WATER
P1.2 PLUMBING PLAN - WASTE & VENT
E0.1 GENERAL NOTES, ELECTRICAL SYMBOL LIST AND SHEET INDEX
E0.2 ELECTRICAL SYMBOLS & DESCRIPTIONS
E1.1 WAREHOUSE POWER PLAN
E1.2 ROOF POWER PLAN
E1.3 OUTDOOR POWER PLAN
E2.1 WAREHOUSE EMERGENCY PHOTOMETRIC PLAN
E2.2 WAREHOUSE LIGHTING PLAN
E2.3 OUTDOOR LIGHTING & PHOTOMETRIC PLANS
E2.4 LUMINARIES SCHEDULE & SPECIFICATION SHEETS
E3.1 SINGLE LINE DIAGRAM & PHOTOCELL SINGLE LINE DIAGRAMS
E3.2 ELECTRICAL SITE PLAN & PANEL SCHEDULES
E4.1 INDOOR LIGHTING TITLE 24 REPORT
E4.2 INDOOR LIGHTING TITLE 24 REPORT
E4.3 OUTDOOR LIGHTING TITLE 24 REPORT
E4.4 OUTDOOR LIGHTING TITLE 24 REPORT
A7.2 ARCHITECTURAL DETAILS
"B" (PER CBC 506.2 AND NONSEPERATED PER CBC 508.3)
m. SKYLIGHT
P0.3 PLUMBING DETAILS
C-1 GENERAL GRADING NOTES & EROSION CONTROL NOTES
C-2 GRADING & DRAINAGE PLAN
C-3 GRADING & DRAINAGE PLAN
C-4 LOW IMPACT DEVELOPMENT PLAN AND DETAILS
ESCP-1 EROSION & SEDIMENT CONTROL NOTES
ESCP-2 EROSION & SEDIMENT CONTROL PLAN
ESCP-3 EROSION & SEDIMENT CONTROL DETAILS (CASQA BMP # TC-1)
ESCP-4 EROSION & SEDIMENT CONTROL DETAILS (CASQA BMP # WM-8)
ESCP-5 EROSION & SEDIMENT CONTROL DETAILS (CASQA BMP # WM-3 & SE-8)
ESCP-6 EROSION & SEDIMENT CONTROL DETAILS (CASQA BMP # WM-9)
1
1
1
L-1 PLANTING PLAN
L-2 IRRIGATION PLAN
L-3 PLANTING AND IRRIGATION DETAILS
L-4 SPECIFICATIONS
n. ROOF TRUSS CALC. TO BE DEFERRED SUBMITTAL
P1.0 PLUMBING SITE PLAN
P1.3 PLUMBING ROOF DRAIN PLAN
E4.5 EQUIPMENT LIST
A6.2 RESTROOM ENLARGED PLANS
2/28/2024 5:59:57 PM
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
DATE NO. DESCRIPTION
DRAWN BY:
DRAWING TITLE
SCALE:
SHEET NO.
REVISION
ACRC
AS SHOWN
unless they are sealed, signed and dated
not final and ready for use, and therefore not valid
As instruments of service, these documents are
of acceptance of these restrictions.
or specifications shall constitute conclusive evidence
of the Architect. Visual contact with these drawings
have been prepared, without the written consent
other than the specific project for which they
shall be reproduced or used for any purpose
property of the Architect and no part thereof
and arrangements represented thereby are the
These drawings, specifications, ideas, designs
5120 HAMNER AVE
# 140
EASTVALE, CA 91752
951.454.8801
PROJECT
DATE: FEB. 08, 2023
PLAN CHECK NO.
A
R
C
ESIGN
www.acrcdesigns.com
P.C. CORRECTION12/27/23
P.C. CORRECTION28/25/23
P.C. CORRECTION32/25/24
A0.2
CONDITIONS
OF APPROVAL
2/28/2024 6:03:42 PM
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
DATE NO. DESCRIPTION
DRAWN BY:
DRAWING TITLE
SCALE:
SHEET NO.
REVISION
ACRC
AS SHOWN
unless they are sealed, signed and dated
not final and ready for use, and therefore not valid
As instruments of service, these documents are
of acceptance of these restrictions.
or specifications shall constitute conclusive evidence
of the Architect. Visual contact with these drawings
have been prepared, without the written consent
other than the specific project for which they
shall be reproduced or used for any purpose
property of the Architect and no part thereof
and arrangements represented thereby are the
These drawings, specifications, ideas, designs
5120 HAMNER AVE
# 140
EASTVALE, CA 91752
951.454.8801
PROJECT
DATE: FEB. 08, 2023
PLAN CHECK NO.
A
R
C
ESIGN
www.acrcdesigns.com
P.C. CORRECTION12/27/23
P.C. CORRECTION28/25/23
P.C. CORRECTION32/25/24
A0.3
GREEN BUILDING
STANDARDS
CODE
SHEET 1
2/28/2024 6:04:17 PM
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
DATE NO. DESCRIPTION
DRAWN BY:
DRAWING TITLE
SCALE:
SHEET NO.
REVISION
ACRC
AS SHOWN
unless they are sealed, signed and dated
not final and ready for use, and therefore not valid
As instruments of service, these documents are
of acceptance of these restrictions.
or specifications shall constitute conclusive evidence
of the Architect. Visual contact with these drawings
have been prepared, without the written consent
other than the specific project for which they
shall be reproduced or used for any purpose
property of the Architect and no part thereof
and arrangements represented thereby are the
These drawings, specifications, ideas, designs
5120 HAMNER AVE
# 140
EASTVALE, CA 91752
951.454.8801
PROJECT
DATE: FEB. 08, 2023
PLAN CHECK NO.
A
R
C
ESIGN
www.acrcdesigns.com
P.C. CORRECTION12/27/23
P.C. CORRECTION28/25/23
P.C. CORRECTION32/25/24
A0.4
GREEN BUILDING
STANDARDS
CODE
SHEET 2
2/28/2024 6:04:43 PM
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
DATE NO. DESCRIPTION
DRAWN BY:
DRAWING TITLE
SCALE:
SHEET NO.
REVISION
ACRC
AS SHOWN
unless they are sealed, signed and dated
not final and ready for use, and therefore not valid
As instruments of service, these documents are
of acceptance of these restrictions.
or specifications shall constitute conclusive evidence
of the Architect. Visual contact with these drawings
have been prepared, without the written consent
other than the specific project for which they
shall be reproduced or used for any purpose
property of the Architect and no part thereof
and arrangements represented thereby are the
These drawings, specifications, ideas, designs
5120 HAMNER AVE
# 140
EASTVALE, CA 91752
951.454.8801
PROJECT
DATE: FEB. 08, 2023
PLAN CHECK NO.
A
R
C
ESIGN
www.acrcdesigns.com
P.C. CORRECTION12/27/23
P.C. CORRECTION28/25/23
P.C. CORRECTION32/25/24
A0.5
GREEN BUILDING
STANDARDS
CODE
SHEET 3
2/28/2024 6:05:06 PM
C.J.C.J.C.J.C.J.
C.J.C.J.C.J.C.J.
90'-0"20'-0"
90'-0"20'-0"
3'
-
1
"
PL PL
9'-0"
6'
-
9
"
18
'
-
3
"
30
'
-
8
"
PL50'-0 3/4"
8'-0"9'-0"6'-0"
PL
PL
PL
PL
12
'
-
0
"
PL
18
'
-
0
"
30'-0"±
CL
25
'
-
0
"
25
'
-
0
"
4'
-
3
"
9'-0"9'-0"
6'
-
9
"
6'
-
0
"
CL
R
.
16'-1"33'-11 3/4"
44
'
-
0
"
1'
-
1
"
4'
-
1
1
"
57'-11"32'-1"
8'-0"8'-0"8'-0"
4'
-
0
"
4'
-
0
"
3'-0"
4'
-
8
"
5'-7 1/4"
2'
-
4
"
3'-0"5'-7 1/4"
2'
-
4
"
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
DATE NO. DESCRIPTION
DRAWN BY:
DRAWING TITLE
SCALE:
SHEET NO.
REVISION
ACRC
AS SHOWN
unless they are sealed, signed and dated
not final and ready for use, and therefore not valid
As instruments of service, these documents are
of acceptance of these restrictions.
or specifications shall constitute conclusive evidence
of the Architect. Visual contact with these drawings
have been prepared, without the written consent
other than the specific project for which they
shall be reproduced or used for any purpose
property of the Architect and no part thereof
and arrangements represented thereby are the
These drawings, specifications, ideas, designs
5120 HAMNER AVE
# 140
EASTVALE, CA 91752
951.454.8801
PROJECT
DATE: FEB. 08, 2023
PLAN CHECK NO.
A
R
C
ESIGN
www.acrcdesigns.com
P.C. CORRECTION12/27/23
P.C. CORRECTION28/25/23
P.C. CORRECTION32/25/24
PROJECT DATA
AND
SITE PLAN
A1.1
LA
P
O
R
T
E
S
T
R
E
E
T
PROPERTY LINE 160'
PROPERTY LINE 160'
PR
O
P
E
R
T
Y
L
I
N
E
5
0
'
PR
O
P
E
R
T
Y
L
I
N
E
5
0
'
10'W x 6'D MIN.
TRASH ENCLOSURE
VAN ACCESSIBLE
50
'
±
T
O
F
I
R
E
H
Y
D
R
A
N
T
142 LA PORTE STREET
PROPOSED 1 STORY
LIGHT INDUSTRIAL BUILDING
UNIT 'A'
134 LA PORTE STREET
ADJACENT PROPERTY
148 LA PORTE STREET
ADJACENT PROPERTY
20
'
W
I
D
E
A
L
L
E
Y
LANDSCAPE
AREA
ASPHALT PAVEMENT
DRIVEWAY
ASPHALT PAVEMENT
DRIVEWAY
TO REMAIN
(E) POWER POLE
(E
)
P
U
B
L
I
C
C
O
N
C
.
S
I
D
E
W
A
L
K
(E
)
L
A
N
D
S
C
A
P
E
D
A
R
E
A
LEGEND
2% SLOPE
2% SLOPE
(E) CMU WALL TO REMAIN
NEW 6'H - CMU WALL
(E) 3'-0"H CMU LOW WALL TO REMAIN
TO REMAIN
(E) TREE
PER CITY STANDARD
UNIT 'B'
UNIT 'C'
(2) 2'x6' BICYCLE PARKING
9'-0" x 18'-0"
CONC. SLAB SIDEWALK
1,372 SQ. FT.1,274 SQ. FT.
1,274 SQ. FT.
TOTAL FLOOR AREA: 3,920 S.F.
PARKING LOT LIGHT POLE
PARKING SPACE
LANDSCAPE
AREA
16'-0"
6'
-
0
"
6'
-
0
"
7'
-
4
"
STEEL SOLID GATE TO BE
APPROVED BY CITY PLANNER
3'
-
0
"
STEEL CANE BOLT WITH SLEEVE
LOCATED ON OUTSIDE OF ONE GATE
CANE DROP BOLT @ INSIDE
4"X12" WOOD TRELLIS
3"X6" WOOD TRELLIS
SOLID ROOF COVER
7'
-
0
"
10'-0"
CONSTRUCTION JOINT
EXPANSION MATERIAL
W/ 1/2" ASPHALT IMPREG.
DOUBLE SWING METAL
GATES STEEL TUBE FRAME
BRACING ON INTERIOR
W/ #3 REBAR AT
6" THICK CONC. SLAB
2'-0" O.C. EA. WAY
TYPICAL
FRAME WITH CROSS
CONC. BUMPER CURB
FOR CANE BOLT
DRILL HOLE IN CONC. SLAB
VERIFY LOCATION IN FIELD
CONCRETE BLOCK WALL
6'
-
0
"
7'-
4
"
4"X12" WOOD TRELLIS
3"X6" WOOD TRELLIS
SOLID ROOF COVER
6'
-
0
"
7'-
4
"
4"X12" WOOD TRELLIS
3"X6" WOOD TRELLIS
SOLID ROOF COVER
6'
-
0
"
7'
-
4
"
4"X12" WOOD TRELLIS
3"X6" WOOD TRELLIS
SOLID ROOF COVER
A TRASH ENCLOSURE ELEVATION
A
D
C
B
B TRASH ENCLOSURE ELEVATION
C TRASH ENCLOSURE ELEVATIONDTRASH ENCLOSURE ELEVATION
PRECISION CONCRETE BLOCK
COLOR: BLACK 100 MW
MANUFACTURER: ORCO BLOCK
EXTERIOR STUCCO
MANUFACTURER: DUNN EDWARDS
COLOR: DET 648 - WHITE PICKET FENCE
EXTERIOR STUCCO
MANUFACTURER: DUNN EDWARDS
COLOR: DET 618 - INDUSTRIAL AGE
EXTERIOR STUCCO
MANUFACTURER: DUNN EDWARDS
COLOR: DET 648 - WHITE PICKET FENCE
EXTERIOR STUCCO
MANUFACTURER: DUNN EDWARDS
COLOR: DET 618 - INDUSTRIAL AGE
EXTERIOR STUCCO
MANUFACTURER: DUNN EDWARDS
COLOR: DET 618 - INDUSTRIAL AGE
SITE PLAN
SCALE: 1/8" = 1'-0"
70 SQ IN MIN REFLECTORIZED
BEADED TEXT OR EQUAL
PORCELAIN STEEL WITH
SIGN CONSTRUCTED OF
1/2" RADIUS (TYP.)
15090 (TYP.)
1.
NOTES:
INTERIOR END OF PARKING SPACE
SIGN TO BE CENTERED AT THE
STANDARD 595B COLOR
BLUE SHALL BE FEDERAL
WHITE FIGURE AND TEXT,
2.
4.
3.
70 SQUARE INCHES
AREA OF SIGN TO BE A MIN. OF
WHERE APPROPRIATE
DESIGNATE FOR "VAN ACCESSIBLE"
USE WALL MOUNTED SIGN INSTEAD
BLUE BACKGROUND WITH
ONLY
PARKING
VAN ACCESSIBLE
IN FRONT OF THE PARKING SPACE.
APPROPRIATE SURFACE IS AVAILABLE
T.O. WALKING SURFACE
60
"
M
I
N
.
ST
A
N
D
I
N
G
S
I
G
N
FO
R
F
R
E
E
80
"
M
I
N
.
OF FREE STANDING SIGN IF A
MO
U
N
T
E
D
S
I
G
N
FO
R
W
A
L
L
7"
10
"
THE SIGN SHALL BE POSTED IN A CONSPICUOUS PLACE
THE SYMBOL SPECIFIED ABOVE SHALL CONSIST OF
A WHITE FIGURE ON A BLUE BACKGROUND. THE
BLUE SHALL BE EQUAL TO COLOR NO. 15090 IN
AT EACH ENTRANCE TO THE OFF-STREET
FEDERAL STANDARD 595a
BACKGROUND
WHITE 4" STRIPE
WHITE FIGURE
BLUE
3'-0"
3'
-
0
"
NO PARKING
H.C. SIGN,
SEE DETAIL
SEE DETAIL
3'-0" SQ. H.C. SYMBOL,
4" WIDE BLUE STRIPING,
DIRECTION
15090 (TYP.)
2% MAX. SLOPE IN ANY
STANDARD 595B COLOR
BLUE SHALL BE FEDERAL
- SEE CIVIL
"ZERO" CURB FACE
12" H. TYP. PAINTED
WHITE LETTERS
18
'
-
0
"
8'-0"9'-0"
3'-0"EQ.EQ.
3'-0"
3--
2--
ACCESSIBLE PARKING STALL
SCALE: N. T. S.
MINIMUM FINE $250
1
HANDICAP SYMBOL
SCALE: N. T. S.2
HANDICAP PARKING SIGNAGE
SCALE: N. T. S.3
TRASH ENCLOSURE
SCALE: N. T. S.4
NEW 6'H - CMU WALL
ACCESSIBLE TRUNCARTED DOME
SCALE: N. T. S.5
36" WIDE ADA TRUNCATED
DOME, SEE 5/A1.1
1 PROVIDE 4'-0" WIDE ACCESSIBLE PATH OF TRAVEL
W/ MAX. 1/2" CHANGE IN ELEVATION, 5% MAX. IN
TRAVEL DIRECTION WITH MAX. 2% CROSS SLOPE
PATH AT DOORS WILL HAVE A 5'x5' AREA THAT
DOES NOT EXCEED 2% SLOPE IN ANY DIRECTION
(GRAPHIC REPRESENTATION ONLY & PATH WILL
NOT BE PAINTED ON THE ACTUAL PAVING) MOUNT
SIGNS INDICATING PATH OF TRAVEL TO THE PUBLIC
WAY ON BUILDING CORNERS
DIG ALERT (811) IS TO BE CONTACTED AND THAT
COMPLIANCE WITH EXCAVATION SAFETY IN
ACCORDANCE WITH GOVERNMENT CODE 4216
WILL BE FOLLOWED PRIOR TO ANY EXCAVATION
TAKING PLACE. PROVIDE AN
ACKNOWLEDGEMENT SIGNATURE SPACE AND
PROVIDE SIGNATIRE BY EITHER THE OWNER OR THE
CONTRACTOR REPRESENTING THE OWNER.
1
EV CHARGER
1
1
2
2
NOTE:
NO EXISTING OR NEW EASEMENTS ON THIS SITE
2
CRAPE MYRTLE TREE
REMOVED 1 EXISTING
TREE TRUNK & STUMP
REMOVED EXIST.
2
2
4'x15' CANOPY
4'x
1
5
'
C
A
N
O
P
Y
4'
x
1
2
'
C
A
N
O
P
Y
4'x6' CANOPY
4'
x
6
'
C
A
N
O
P
Y
4'
x
6
'
C
A
N
O
P
Y
TREE TRUNK & STUMP
REMOVED EXIST.
3
3
2/28/2024 6:05:56 PM
3
7
9
5 2
1
4
6
SCALE
N.T.S.BUILDING ENTRY SIGN
SCALE
N.T.S.SIGNS / BRAILLE
SCALE
N.T.S.
ACCESSIBLE DOOR
CLEARANCES
SCALE
N.T.S.BUILDING EXIT SIGN
SCALE
N.T.S.
ACCESSIBLE DOOR
CLEARANCES
SCALE
N.T.S.WIDTH OF ACCESSIBLE ROUTE
SCALE
N.T.S.
CLEAR WIDTH AT
ROUTE / TURN
SCALE
N.T.S.FLOOR / GROUND SURFACE
SCALE
N.T.S.
ACCESSIBLE DOORS
IN A SERIES
11B-703.2 RAISED CHARACTERS.
RAISED CHARACTERS SHALL COMPLY WITH SECTION 11B-703.2 AND SHALL BE DUPLICATED IN BRAILLE COMPLYING WITH
SECTION 11B-703.3. RAISED CHARACTERS SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 11B-703.4.
11B-703.2.1 DEPTH
RAISED CHARACTERS SHALL BE 1/32 INCH (0.8 mm) MINIMUM ABOVE THEIR BACKGROUND.
11B-703.2.2 CASE
CHARACTERS SHALL BE UPPERCASE.
11B-703.2.3 STYLE
CHARACTERS SHALL BE SANS SERIF. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY
DECORATIVE, OR OF OTHER UNUSUAL FORMS.
11B-703.2.5 CHARACTER HEIGHT
CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASELINE OF THE CHARACTER SHALL BE 5/8
INCH MINIMUM AND 2 INCHES MAXIMUM BASED ON THE HEIGHT OF THE UPPERCASE LETTER "I".
11B-703.3 BRAILLE.
BRAILLE SHALL BE CONTRACTED (GRADE 2) AND SHALL COMPLY WITH SECTIONS 11B-703.3 AND 11B-703.4.
11B-703.3.1 DIMENSIONS AND CAPITALIZATION
BRAILLE DOTS SHALL HAVE A DOMED OR ROUNDED SHAPE AND SHALL COMPLY WITH TABLE 11B-703.3.1
11B-703.4 INSTALLATION HEIGHT AND LOCATION
SIGNS WITH TACTILE CHARACTERS SHALL COMPLY WITH SECTION 11B-703.4.
11B-703.4.1 HEIGHT ABOVE FINISH FLOOR OR GROUND.
TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES MINIMUM ABOVE THE FINISH FLOOR
OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST BRAILLE CELLS AND 60
INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE
OF THE HIGHEST LINE OF RAISED CHARACTERS.
11B-703.4.2 LOCATION
WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONGSIDE THE DOOR AT THE LATCH
SIDE. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON
THE INACTIVE LEAF. WHERE A TACTILE SIGN IS PROVIDE AT DOUBLE DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE
LOCATED TO THE RIGHT OF THE RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE AT THE LATCH SIDE OF A SINGLE
DOOR OR AT THE RIGHT SIDE OF DOUBLE DOORS, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL. SIGNS
CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18 INCHES
MINIMUM BY 18 INCHES MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR
SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. WHERE PERMANENT IDENTIFICATION
SIGNAGE IS PROVIDED FOR ROOMS AND SPACES THEY SHALL BE LOCATED ON THE APPROACH SIDE OF THE
DOOR AS ONE ENTERS THE ROOM OR SPACE. SIGNS THAT IDENTIFY EXITS SHALL BE LOCATED ON THE APPROACH SIDE
OF THE DOOR AS ONE EXITS THE ROOM OR SPACE.
11B-703.5 VISUAL CHARACTERS SHALL COMPLY WITH SECTION 11B-703.5.
11B-703.5.1 FINISH AND CONTRAST
CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. CHARACTERS SHALL
CONTRAST WITH THEIR BACKGROUND WITH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK
CHARACTERS ON A LIGHT BACKGROUND.
11B-703.6 PICTOGRAMS
PICTOGRAMS SHALL COMPLY WITH SECTION 11B-703.6.
11B-703.6.1 PICTOGRAM FIELD
PICTOGRAMS SHALL HAVE A FIELD HEIGHT OF 6 INCHES MINIMUM. CHARACTERS AND BRAILLE SHALL NOT BE
LOCATED IN THE PICTOGRAM FIELD.
TACTILE EXIT SIGN
EXIT
4"
4"
NOTES:
TACTILE EGRESS SIGNAGE (SECURE TO STOREFRONT GLASS W/
ADHESIVE). PROVIDE PLASTIC BACKING OVER OTHER SIDE OF
GLASS FOR COVERAGE. ADHESIVE SHALL BE COMPATIBLE w/
GLASS APPLICATION.
EXIT
60
"
M
A
X
.
WHITE INTERNATIONAL SYMBOL
OF ACCESSIBILITY
RAISED GRADE 2 BRAILLE:
"EXIT".
A.F
.
F
.
48
"
M
I
N
.
A.
F
.
F
.
ACCESSIBILITY NOTES
1. GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES AND IN ACCESSIBLE ROOMS AND SPACES INCLUDING FLOORS,
WALKS, RAMPS, STAIRS AND CURB RAMPS SHALL BE STABLE, FIRM AND SLIP RESISTANT.
2. OPENINGS IN FLOOR OR GROUND SURFACES SHALL NOT ALLOW PASSAGE OF A SPHERE MORE THAN 1/2" DIAMETER EXCEPT
AS ALLOWED IN SECTIONS 11B-407.4.3, 11B-409.4.3, 11B-410.4, 11B-810.5.3 AND 11B-810.10. ELONGATED OPENINGS SHALL BE
PLACED SO THAT THE LONG DIMENSION IS PERPENDICULAR TO THE DOMINANT DIRECTION OF TRAVEL. (11B-302.3).
3. ALL NEW CONSTRUCTION MUST COMPLY WITH DIMENSIONS AS DENOTED ON THESE CONSTRUCTION DOCUMENTS AND WITH
CHAPTER 11B OF THE 2019 CBC. DIMENSIONS WITHIN A SPECIFIED DIMENSIONAL "RANGE" MUST BE LESS-THAN THE MAXIMUM
DIMENSIONAL RANGE OR GREATER THAN THE MINIMUM DIMENSIONAL RANGE. IN OTHER WORDS, NEW CONSTRUCTION
SHALL NOT BE EQUAL TO EITHER THE MAXIMUM OR MINIMUM DIMENSIONS, BUT SHALL BE LESS THAN THE MAXIMUM AND
GREATER THAN THE MINIMUM. MAXIMUM SLOPES FOR NEW RAMPS SHALL BE ONE (1) VERTICAL TO 12 HORIZONTAL
MAXIMUM. DESIGN INTENT OF ARCHITECT IS TO PROVIDE REASONABLE DIMENSIONAL TOLERANCES, ENSURE COMPLIANCE
WITH THE ADA, AND TO SIMPLIFY AND EXPEDITE THE CONSTRUCTION PROCESS. CONTRACTOR SHALL BE HELD FULLY
RESPONSIBLE FOR NON-COMPLIANCE WITH THIS NOTICE. CONTRACTOR TO NOTIFY ARCHITECT IN WRITING PRIOR TO
BIDDING OF ANY QUESTIONS OR CONCERNS RELATING TO THIS MATTER.
4. DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME
REQUIRED TO MOVE THE DOOR TO A POSITION 12 DEGREES FROM THE LATCH IS
5 SECONDS MINIMUM. (11B-404.2.8.1).
5. THE FORCE FOR PUSHING OR PULLING A DOOR OR GATE OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS:
1. INTERIOR HINGED DOORS AND GATES: 5 POUNDS (22.2 N) MAXIMUM.
2. SLIDING OR FOLDING DOORS: 5 POUNDS (22.2 N) MAXIMUM.
3. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE
ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS (66.7 N).
4. EXTERIOR HINGED DOORS: 5 POUNDS (22.2 N) MAXIMUM.
THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT
HOLD THE DOOR OR GATE IN A CLOSED POSITION. (11B-404.2.9).
6. POWER-OPERATED DOORS. WHERE MEANS OF EGRESS DOORS ARE OPERATED BY POWER, SUCH AS DOORS WITH A
PHOTOELECTRIC-ACTUATED MECHANISM TO OPEN THE DOOR UPON THE APPROACH OF A PERSON, OR DOORS WITH
POWER-ASSISTED MANUAL OPERATION, THE DESIGN SHALL BE SUCH THAT IN THE EVENT OF POWER FAILURE, THE DOOR IS
CAPABLE OF BEING OPENED MANUALLY TO PERMIT MEANS OF EGRESS TRAVEL OR CLOSED WHERE NECESSARY TO
SAFEGUARD MEANS OF EGRESS. THE FORCES REQUIRED TO OPEN THESE DOORS MANUALLY SHALL NOT EXCEED THOSE
SPECIFIED IN SECTION 1010.1.3, EXCEPT THAT THE FORCE TO SET THE DOOR IN MOTION SHALL NOT EXCEED 50 POUNDS (220
N). THE DOOR SHALL BE CAPABLE OF SWINGING FROM ANY POSITION TO THE FULL WIDTH OF THE OPENING IN WHICH SUCH
DOOR IS INSTALLED WHEN A FORCE IS APPLIED TO THE DOOR ON THE SIDE FROM WHICH EGRESS IS MADE.
FULL-POWER-OPERATED DOORS SHALL COMPLY WITH BHMA A156.10. POWER-ASSISTED AND LOW-ENERGY DOORS SHALL
COMPLY WITH BHMA A156.19. (CBC SECTION 1008.1.4.2).
7. TEST DOORS FOR DOOR OPENING FORCE AND CLOSING SPEED WITH AIR CONDITIONING AND OTHER FORMS OF
MECHANICAL PRESSURIZATION TURNED ON AND ALSO WHEN TURNED OFF.
CARPET PILE HEIGHT
1/
2
"
MA
X
.
1/
4
"
MA
X
.
NOTES:
VERTICAL CHANGE IN LEVEL
BEVELED CHANGE IN LEVEL
1/
2
"
MA
X
.
1/
4
"
MA
X
.
1/
4
"
MA
X
.
1. CARPET OR CARPET TILE SHALL BE SECURELY ATTACHED AND SHALL HAVE A FIRM CUSHION, PAD,
OR BACKING OR NO CUSHION OR PAD. CARPET OR CARPET TILE SHALL HAVE A LEVEL LOOP,
TEXTURED LOOP, LEVEL CUT PILE, OR LEVEL CUT/UNCUT PILE TEXTURE. PILE HEIGHT SHALL BE 1/2"
MAXIMUM. EXPOSED EDGES OF CARPET SHALL BE FASTENED TO FLOOR SURFACES AND SHALL
HAVE TRIM ON THE ENTIRE LENGTH OF THE EXPOSED EDGE. CARPET EDGE TRIM SHALL COMPLY
WITH SECTION 11B-303. (11B-302.2).
2. CHANGES IN LEVEL OF 1/4" HIGH MAXIMUM SHALL BE PERMITTED TO BE VERTICAL AND WITHOUT
EDGE TREATMENT. (11B-303.2).
3. CHANGES IN LEVEL BETWEEN 1/4" HIGH MINIMUM AND 1/2" HIGH MAXIMUM SHALL BE BEVELED
WITH A SLOPE NOT STEEPER THAN 1:2. (11B-303.3).
4. THRESHOLDS SHALL BE 1/2" HIGH MAXIMUM. RAISED THRESHOLDS AND CHANGES IN LEVEL AT
DOORWAYS SHALL COMPLY WITH SECTION 11B-302 AND 11B-303. (11B-404.2.5).
FIGURE 11B-403.5.1
CLEAR WIDTH OF AN ACCESSIBLE ROUTE
32
-
1
/
4
"
36
-
1
/
4
"
23-3/4"
MAX
48-1/4" MIN
CLEAR
23-3/4"
MAX
MI
N
C
L
R
MI
N
C
L
R
NOTE:
1. THE CLEAR WIDTH SHALL BE PERMITTED TO BE REDUCED TO 32-1/4" MINIMUM FOR A LENGTH
OF 23-3/4" MAXIMUM PROVIDED THAT REDUCED WIDTH SEGMENTS ARE SEPARATED BY
SEGMENTS THAT ARE 48-1/4" LONG MINIMUM AND 36-1/4" WIDE MINIMUM.
(11B-403.5.1 EXCEPTION 1).
MINIMUM MANEUVERING CLEARANCE
APPROACH
DIRECTION
PERPENDICULAR
TO DOORWAY
PARALLEL TO DOORWAY
(beyond stop/latch side
unless noted)
FROM FRONT
FROM SIDE
48-1/8 INCHES 0 INCHES
FROM POCKET/HINGE SIDE 22-1/8 INCHES
FROM STOP/LATCH SIDE 42-1/8 INCHES
1. DOORWAY WITH NO DOOR ONLY.
2. BEYOND POCKET/HINGE SIDE.
242-1/8 INCHES
42-1/8 INCHES 0 INCHES
24-1/8 INCHES
1
48
-
1
/
8
"
M
I
N
(a)
Front Approach
22-1/8"
MIN 42
-
1
/
8
"
MIN
(c)
Pocket or Hinge Approach
24-1/8"
MIN42
-
1
/
8
"
MIN
(d)
Stop or Latch Approach
FIGURE 404.2.4.2
42
-
1
/
8
"
M
I
N
(b)
Side Approach
FIGURE 11B-404.2.4.2
MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND
FOLDING DOORS
TABLE 11B-404.2.4.2
MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS OR GATES, MANUAL
SLIDING DOORS, AND MANUAL FOLDING DOORS
NOTES:
1. THE MINIMUM WIDTH OF EXIT PASSAGEWAYS SHALL BE DETERMINED AS SPECIFIED IN SECTION 1005.1
BUT SUCH WIDTH SHALL NOT BE LESS THAN 44 INCHES, EXCEPT THAT EXIT PASSAGEWAYS SERVING AN
OCCUPANT LOAD OF LESS THAN 50 SHALL NOT BE LESS THAN 36 INCHES IN WIDTH. THE REQUIRED
WIDTH OF EXIT PASSAGEWAYS SHALL BE UNOBSTRUCTED. (11B-1023.2).
2. AN ACCESSIBLE ROUTE WITH A CLEAR WIDTH LESS THAN 60 INCHES SHALL PROVIDE PASSING SPACES
AT INTERVALS OF 200 FEET MAXIMUM. PASSING SPACES SHALL BE EITHER: A SPACE 60 INCHES
MINIMUM BY 60 INCHES MINIMUM; OR , AN INTERSECTION OF TWO WALKING SURFACES PROVIDING A
T-SHAPED SPACE COMPLYING WITH SECTION 11B-304.2 WHERE THE BASE AND ARMS OF THE T-SHAPED
SPACE EXTEND 48 INCHES MINIMUM BEYOND THE INTERSECTION. (11B-403.5.3).
48
-
1
/
4
"
M
I
N
X < 48"
(a)
180 DEGREE TURN
42-1/4"
MIN
42-1/4"
MIN
FIGURE 11B-403.5.2 CLEAR WIDTH AT TURN
X < 48"
60
-
1
/
4
"
M
I
N
36-1/4"
MIN
36-1/4"
MIN
(b)
180 DEGREE TURN (EXCEPTION)
TYPE OF USE
18-1/8"
MIN60
-
1
/
8
"
M
I
N
(a)
Front Approach, Pull Side
48
-
1
/
8
"
M
I
N
(b)
Front Approach, Push Side
36-1/8"
MIN
(d)
Hinge Approach, Pull Side
22-1/8"
MIN44
-
1
/
8
"
MIN
(f)
Hinge Approach, Push Side
24-1/8"
MIN60
-
1
/
8
"
M
I
N
(h)
Latch Approach, Pull Side
(j)
Latch Approach, Push Side
24-1/8"
MIN 44
-
1
/
8
"
MI
N
MINIMUM MANEUVERING CLEARANCE
APPROACH
DIRECTION
DOOR
SIDE
PERPENDICULAR
TO DOORWAY
PARALLEL TO DOORWAY
(beyond latch side unless noted)
FROM FRONT PULL 60 INCHES 18 INCHES
FROM FRONT PUSH 48 INCHES 0 INCHES
FROM HINGE SIDE PULL 60 INCHES 36 INCHES
PUSH 44 INCHES
PULL 24 INCHES
PUSH 44 INCHES
60 INCHES
24 INCHES
22 INCHES
1. ADD 12 INCHES IF CLOSER AND LATCH ARE PROVIDED.
2. ADD 4 INCHES IF CLOSER AND LATCH ARE PROVIDED.
3. BEYOND HINGE SIDE.
4. ADD 4 INCHES IF CLOSER IS PROVIDED.
5. ADD 6 INCHES AT EXTERIOR SIDE OF EXTERIOR DOORS.
4
1
3
60
-
1
/
8
"
M
I
N
(a)
Pull Side
X
>
8
"
48
-
1
/
8
"
MI
N
(b)
Push Side
X
>
8
"
(c)
Push Side, Door provided with
both closer and latch
48
-
1
/
8
"
MI
N
X
>
8
"
12-1/8"
MIN
8
48
-
1
/
8
"
M
I
N
(c)
Front Approach, Push Side
12-1/8"
MIN
Door provided with closer and latch
22-1/8"
MIN48
-
1
/
8
"
M
I
N
(g)
Hinge Approach, Push Side, Door
provided with both closer and latch
(k)
Latch Approach, Push Side
Door provided with closer
24-1/8"
MIN 48
-
1
/
8
"
MI
N
TABLE 11B-404.2.4.1
MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
NOTES:
1. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS AND
GATES SHALL COMPLY WITH SECTION 11B-309.4. OPERABLE PARTS OF SUCH
HARDWARE SHALL BE (CENTERED BETWEEN) 34 INCHES MINIMUM AND 44 INCHES
MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. (11B-404.2.7).
2. DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES MINIMUM. (11B-404.2.3).
Add 6 inches
at exterior side
of exterior door
FIGURE 11B-404.2.4.3
MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES
18-1/8" MIN
AT INTERIOR
24-1/8" MIN
AT EXTERIOR
5
2
FIGURE 11B-404.2.4.1
MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
NOTE:
1. THE DISTANCE BETWEEN TWO HINGED OR PIVOTED DOORS IN SERIES AND GATES IN SERIES SHALL BE
48 1/8" INCHES MINIMUM PLUS THE WIDTH OF DOORS OR GATES SWINGING INTO THE SPACE.
(11B-404.2.6).
(c)
48 1/8"
MIN. CLR.
(b)
48 1/8"
MIN. CLR.
(a)
48 1/8"
MIN. CLR.
FIGURE 11B-404.2.6
DOORS IN SERIES AND GATES IN SERIES
MEASUREMENT RANGE MINIMUM IN INCHES
MAXIMUM IN INCHES
DOT BASE DIAMETER
DISTANCE BETWEEN TWO
DOTS IN THE SAME CELL
0.059 TO 0.063
1. MEASURED CENTER TO CENTER
DISTANCE BETWEEN CORRESPONDING DOTS IN
ADJACENT CELLS
DOT HEIGHT
0.090 TO 0.100
0.241 TO 0.300
0.025 TO 0.037
0.395 TO 0.400
DISTANCE BETWEEN CORRESPONDING DOTS FROM
ONE CELL DIRECTLY BELOW
1
1. BRAILLE SHALL BE CONTRACTED (GRADE 2) AND SHALL COMPLY WITH SECTIONS 11B-703.3 AND
11B-703.4. (11B-703.3).
2. BRAILLE DOTS SHALL HAVE A DOMED OR ROUNDED SHAPE AND SHALL COMPLY WITH FIGURE
11B-703.3.1. THE INDICATION OF AN UPPERCASE LETTER OR LETTERS SHALL ONLY BE USED BEFORE
THE FIRST WORD OF SENTENCES, PROPER NOUNS AND NAMES, INDIVIDUAL LETTERS OF THE
ALPHABET, INITIALS, AND ACRONYMS. (11B-703.3.1).
3. BRAILLE SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT IN A HORIZONTAL FORMAT,
FLUSH LEFT OR CENTERED. IF TEXT IS MULTI-LINED, BRAILLE SHALL BE PLACED BELOW THE ENTIRE
TEXT. BRAILLE SHALL BE SEPARATED 3/8 INCH (9.5 MM) MINIMUM AND 1/2 INCH MAXIMUM FROM
ANY OTHER TACTILE CHARACTERS AND 3/8 INCH (9.5 MM) MINIMUM FROM RAISED BORDERS
AND DECORATIVE ELEMENTS. (11B-703.3.2).
TABLE 11B-703.3.1 BRAILLE DIMENSIONS
DOT DIAMETER
RAISED DOT
NO RAISED DOT
DISTANCE BETWEEN DOTS IN
THE SAME CELL
SINGLE BRAILLE
CELL
DISTANCE BETWEEN
CORRESPONDING DOTS IN
ADJACENT CELLS
DISTANCE BETWEEN
DOTS IN THE SAME CELL
DISTANCE BETWEEN
CORRESPONDING DOTS
FROM ONE CELL DIRECTLY
BELOW
BLANK CELL SPACE
BETWEEN WORDS
FIGURE 703.3.1
BRAILLE MEASUREMENT
1 2
ST
R
I
K
E
S
I
D
E
E
D
G
E
O
F
DO
O
R
/
O
P
E
N
I
N
G
F
R
A
M
E
1'-0"
WHITE INTERNATIONAL SYMBOL
OF ACCESSIBILITY
BLUE BACKGROUND COLOR 15090 OF
FEDERAL STANDARD NUMBER 595B
BUILDING ENTRY SIGNAGE (SECURE TO
STOREFRONT GLASS W/ ADHESIVE).
PROVIDE PLASTIC BACKING ON OTHER
SIDE OF GLASS FOR COVERAGE.
ADHESIVE SHALL BE COMPATIBLE W/
GLASS APPLICATION.
6"
6"
60
"
A.
F
.
F
.
FIGURE 11B-703.7.2.1
INTERNATIONAL SYMBOL OF ACCESSIBILITY
CL
60
-
1
/
8
"
M
I
N
(e)
Reserved
(i)
Reserved
FROM HINGE SIDE
FROM LATCH SIDE
FROM LATCH SIDE
1
1
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
DATE NO. DESCRIPTION
DRAWN BY:
DRAWING TITLE
SCALE:
SHEET NO.
REVISION
ACRC
AS SHOWN
unless they are sealed, signed and dated
not final and ready for use, and therefore not valid
As instruments of service, these documents are
of acceptance of these restrictions.
or specifications shall constitute conclusive evidence
of the Architect. Visual contact with these drawings
have been prepared, without the written consent
other than the specific project for which they
shall be reproduced or used for any purpose
property of the Architect and no part thereof
and arrangements represented thereby are the
These drawings, specifications, ideas, designs
5120 HAMNER AVE
# 140
EASTVALE, CA 91752
951.454.8801
PROJECT
DATE: FEB. 08, 2023
PLAN CHECK NO.
A
R
C
ESIGN
www.acrcdesigns.com
P.C. CORRECTION12/27/23
P.C. CORRECTION28/25/23
P.C. CORRECTION32/25/24
ADA
STANDARDS
A1.2
2/28/2024 6:06:17 PM
49'-3"8'-8"32'-1"
90'-0"
2'
-
0
"
10
'
-
0
"
2'
-
0
"
12
'
-
0
"
3'
-
4
"
15
'
-
4
"
3'
-
4
"
14
'
-
0
"
30
'
-
0
"
44
'
-
0
"
4'-0"
2'-8"2'-8"12"12"4'-0"
4'-0"9'-4"4'-0"9'-4"4'-0"
4'-0"9'-4"
15'-4"2'-0"
3'-4"3'-4"
3'
-
4
"
6'
-
0
"
7'
-
0
"
2'
-
0
"
7'
-
0
"
6'
-
0
"
6'
-
0
"
2'
-
0
"
22
'
-
0
"
22
'
-
0
"
44
'
-
0
"
2'
-
8
"
6'
-
0
"
2'
-
8
"
8"
16"
14'-9"8'-0"7'-1"
8'
-
6
"
8'
-
0
"
13
'
-
4
"
13
'
-
4
"
8'
-
0
"
2 134
134
AA
BB
C
DD
8"
8"
9'-4"
16'-8"17'-0"3'-8"
88'-8"
16"
8"
8"
EX
I
T
EX
I
T
EX
I
T
C.J.C.J.C.J.C.J.
C.J.C.J.C.J.C.J.
2'
-
0
"
6"
2'
-
2
"
3'
-
4
"
2'
-
2
"
6"
2'-6"
2'-6"
3'-2"
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
DATE NO. DESCRIPTION
DRAWN BY:
DRAWING TITLE
SCALE:
SHEET NO.
REVISION
ACRC
AS SHOWN
unless they are sealed, signed and dated
not final and ready for use, and therefore not valid
As instruments of service, these documents are
of acceptance of these restrictions.
or specifications shall constitute conclusive evidence
of the Architect. Visual contact with these drawings
have been prepared, without the written consent
other than the specific project for which they
shall be reproduced or used for any purpose
property of the Architect and no part thereof
and arrangements represented thereby are the
These drawings, specifications, ideas, designs
5120 HAMNER AVE
# 140
EASTVALE, CA 91752
951.454.8801
PROJECT
DATE: FEB. 08, 2023
PLAN CHECK NO.
A
R
C
ESIGN
www.acrcdesigns.com
P.C. CORRECTION12/27/23
P.C. CORRECTION28/25/23
P.C. CORRECTION32/25/24
FLOOR PLAN
A2.1
EXIT SIGN & LOW LEVEL EXIT SIGN
LIGHTED SURFACE
DIRECTIONAL ARROW
TACTILE EXIT SIGN SHALL BE REQUIRED
ROOM NAME
OCCUPANCY TYPE
FLOOR AREA
OCCUPANCY LOAD FACTOR
NAME
A3 1234
1/200 12
OCCUPANCY LOAD
EXITS, EXIT ACCESS DOORS AND PATHS OF EGRESS
OCCUPANTS SHALL BE MARKED BY AN APPROVED
DIRECTION OF EGRESS TRAVEL.
- EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY
TIME OF FIELD INSPECTION.
FLOOR PLAN
SCALE: 1/4" = 1'-0"
NO
R
T
H
B
A6.2
OFFICE
B 100
1 / 150 2
5
EXIT - EGRESS SIZING CALCULATION
5 OCCUPANTS X 0.2" = 1.0 LINEAR INCHES REQUIRED
EXISTING = 36 LINEAR INCHES PROVIDED
LEGEND
1 DOOR NUMBER
SEE DOOR SCHEDULE
A WINDOW NUMBER
SEE DOOR SCHEDULE
NON-RATED INTERIOR PARTITION: (SEE STRUCTURAL)
RESTROOM: CERAMIC TILE
OFFICE AREA: 5" RUBBER BASE
PAINT WITH KNOCKDOWN TEXTURE
GYPSUM BOARD WITH TWO COATS ENAMEL
OFFICE AREA: COMMERCIAL GRADE LAMINATE FLOOR
ENAMEL PAINT WITH KNOCKDOWN TEXTURE
GYPSUM BOARD WITH TWO COATS SEMI-GLOSS
CEILING
WALL
BASE
FLOOR
OFFICE AREA:
RESTROOMS:
FINISH NOTES
EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIME. TO ENSURE CONTINUED
ILLUMINATION FOR A DURATION OF NOT LESS THAN 90 MINUTES IN CASE
OF PRIMARY POWER LOSS. THE SIGN ILLUMINATION MEANS SHALL BE
CONNECTED TO AN EMERGENCY POWER SYSTEM PROVIDED FROM STORAGE
BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR. THE INSTALLATION
OF THE EMERGENCY POWER SYSTEM SHALL BE IN ACCORDANCE WITH
CHAPTER 27.
13. PROVIDE THE FOLLOWING SIGN WITH 1" HIGH; LETTERING ON THE MAIN EXIT
DOOR / DOOR FRAME SERVING B, F, M, S & A (LESS THAN 300 OCCUPANTS)
STATING; "THIS DOOR TO REMAIN UN-LOCKED WHEN BUILDING IS OCCUPIED"
SEE ELECTRICAL PLANS FOR PANEL SCHEDULE AND LOADS
SEE PLUMBING PLANS FOR WASTE & VENTS INFORMATION
SEE MECHANICAL REFLECTED CEILING PLAN FOR HVAC LOCATIONS
12.
14.
15.
16.
THE USE OF A KEY, SPECIAL KNOWLEDGE, OR EFFORT.
WATER CLOSET - 1.28 GPF
ALL EXIT DOORS AND GATES MUST BE OPERABLE FROM EGRESS SIDE WITHOUT
PLUMBING FIXTURES SHALL COMPLY WITH WATER CONSERVATION FLOW RATES:
ALL NEW DOORS AND GATES MUST BE EQUIPPED WITH LEVER TYPE HANDLE.
WALL AND CEILING MATERIALS SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS.5.
ALL WEATHER-EXPOSED SURFACES SHALL HAVE A WEATHER-RESISTIVE BARRIER TO
PROTECT THE INTERIOR WALL COVERING AND THAT EXTERIOR OPENINGS SHALL BE
FLASHED IN SUCH A MANNER AS TO MAKE THEM WEATHERPROOF.
4.
1.
2.
LAVATORY FAUCETS - 0.4 GPM; KITCHEN FAUCETS-1.8 GPM
3.
LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED SHALL BE OPERABLE WITH A
OTHER HARDWARE THAT PROVIDES PASSAGE WITHOUT GRASPING.
HAND-ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 30" AND 44"
MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS. FOR EXTERIOR AND
THE BOTTOM 10" IF ALL DOORS, EXCEPT AUTOMATIC AND SLIDING, MUST HAVE A SMOOTH
DOOR THRESHOLD SHALL BE NO HIGHER THAN 1/4".
EXTERIOR DOORS SHALL HAVE WEATHERSTRIPPING ALL SIDES.
SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BAR PUSH-PULL ACTIVATING BARS OR
ABOVE THE FLOOR.
INTERIOR DOORS AND 15 LBS. FOR FIRE DOORS.
UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST.
6.
7.
8.
9.
10.
11.
OF SPECIFIED WALLBOARD (ON RESTROOM SIDE)
* USE WATER RESISTENT GYPSUM BOARD IN LIEU
1 5/8" x 6", 18 GA. METAL STUD @ 16" O.C.
WITH 5/8" TYPE 'X' GYPSUM BOARDS ON BOTH SIDES
OF SPECIFIED WALLBOARD (ON RESTROOM SIDE)
* USE WATER RESISTENT GYPSUM BOARD IN LIEU
1 1/2 x 3 1/2, 20 GA. METAL STUD @ 16" O.C.
WITH 5/8" GYPSUM BOARDS ON BOTH SIDES
FIRE RATED INTERIOR PARTITION: (SEE STRUCTURAL)
NOTES:
WAREHOUSE: CONCRETE SLAB
RESTROOM: CERAMIC TILE
ENAMEL PAINT WITH KNOCKDOWN TEXTURE
GYPSUM BOARD WITH TWO COATS SEMI-GLOSS
RESTROOMS:
w/ FLUSH MOUNTED FLUORESCENT LIGHT FIXTURES
2'x2' SUSPENDED ACOUSTICAL TILE CEILING PANEL
OFFICE AREA:
TRAVEL THAT IS NOT IMMEDIATELY VISIBLE TO THE
EXIT SIGN THAT IS READILY VISIBLE FROM ANY
ILLUMINATED.
-ADDITIONAL EXITS SIGNS MAY BE REQUIRED AT
WAREHOUSE
S2 1,217
1 / 500 3
OFFICE
B 100
1 / 150 2
WAREHOUSE
S2 1,132
1 / 500 3
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,106
1 / 500 3
WITH FIRE SPRINKLER SYSTEM
INDICATES EXIT ACCESS TRAVEL DISTANCE
EMERGENCY LIGHT WITH 90 MINUTE BATTERY BACKUP
OR UNIT MOUNTED EMERGENCY INVERTER.
PROVIDE UNSWITCHED HOT WIRE AS NOTED.
TR
A
V
E
L
D
I
S
T
A
N
C
E
=
6
0
'
-
0
"
5
5
EXIT - EGRESS SIZING CALCULATION
5 OCCUPANTS X 0.2" = 1.0 LINEAR INCHES REQUIRED
EXISTING = 36 LINEAR INCHES PROVIDED
EXIT - EGRESS SIZING CALCULATION
5 OCCUPANTS X 0.2" = 1.0 LINEAR INCHES REQUIRED
EXISTING = 36 LINEAR INCHES PROVIDED
1
1
1
23
2
2
3
3
4
5
5
A
B ABOVE
A B ABOVECGABOVECGABOVECGABOVECGABV
D
G
G
G
B
A6.2
TR
A
V
E
L
D
I
S
T
A
N
C
E
=
7
5
'
-
0
"
TR
A
V
E
L
D
I
S
T
A
N
C
E
=
7
4
'
-
0
"
FIRE RESISTANT 12" CMU WALL & EXTERIOR CEMENT
PLASTER ON THE EXTERIOR SURFACE. SEE DTL. 13/A7.2
1
14
A7.2
FIRE RATED
CONTROL JOINT
SEE DETAIL, TYP.
2/28/2024 6:35:13 PM
SL
O
P
E
1/
4
"
:
1
2
SL
O
P
E
1/
4
"
:
1
2
SL
O
P
E
1/
4
"
:
1
2
EX
I
T
EX
I
T
EX
I
T
C.J.C.J.C.J.C.J.
C.J.C.J.C.J.C.J.
4'-0"4'-0"9'-4"4'-0"9'-4"4'-0"15'-4"2'-0"16'-8"17'-0"3'-0"
C.J.C.J.C.J.C.J.
2'
-
0
"
3'
-
4
"
2'
-
0
"
12
'
-
0
"
15
'
-
4
"
2'
-
8
"
3'
-
4
"
3'
-
4
"
2'
-
6
"
3'
-
4
"
8'
-
8
"
6'
-
0
"
3'
-
0
"
6'
-
0
"
8'
-
8
"
3'
-
4
"
2'
-
6
"
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
DATE NO. DESCRIPTION
DRAWN BY:
DRAWING TITLE
SCALE:
SHEET NO.
REVISION
ACRC
AS SHOWN
unless they are sealed, signed and dated
not final and ready for use, and therefore not valid
As instruments of service, these documents are
of acceptance of these restrictions.
or specifications shall constitute conclusive evidence
of the Architect. Visual contact with these drawings
have been prepared, without the written consent
other than the specific project for which they
shall be reproduced or used for any purpose
property of the Architect and no part thereof
and arrangements represented thereby are the
These drawings, specifications, ideas, designs
5120 HAMNER AVE
# 140
EASTVALE, CA 91752
951.454.8801
PROJECT
DATE: FEB. 08, 2023
PLAN CHECK NO.
A
R
C
ESIGN
www.acrcdesigns.com
P.C. CORRECTION12/27/23
P.C. CORRECTION28/25/23
P.C. CORRECTION32/25/24
REFLECTED
CEILING
PLAN
A2.2
REFLECTED CEILING PLAN
SCALE: 1/4" = 1'-0"
NO
R
T
H
C-1
C-2
CEILING SYMBOLS:
C-1
C-1
C-2
C-2
C-1C-2
10'-0"
CLG. HT.
8'-0"
CLG. HT.
8'-0"
CLG. HT.
10'-0"
CLG. HT.
10'-0"
CLG. HT.
8'-0"
CLG. HT.
±22'-6"
CLG. HT.
±22'-6"
CLG. HT.
±22'-6"
CLG. HT.
@13'-4" A.F.F.
SCALE: 1/4" = 1'-0"
@13'-4" A.F.F.
SCALE: 1/4" = 1'-0"
2'x2' SUSPENDED ACOUSTICAL TILE CEILING PANEL
w/ FLUSH MOUNTED FLUORESCENT LIGHT FIXTURES
SEE DETAIL #1 TO #5/A7.2
GYPSUM BOARD WITH TWO COATS SEMI-GLOSS
ENAMEL PAINT WITH KNOCKDOWN TEXTURE
2'-0" x 2'-0" SUSPENDED LED LIGHT FIXTURE ON
CEILING SYSTEM PER PLANS, REFER TO
ELECTRICAL DRAWINGS FOR FIXTURE
SUPPLY AIR DIFFUSERS OR EXHAUST FANS
WHERE SHOWN PER MECHANICAL DRAWINGS
RETURN AIR DIFFUSERS OR EXHAUST FANS
WHERE SHOWN PER MECHANICAL DRAWINGS
INTERIOR WALL MOUNTED LIGHT FIXTURE
REFER TO ELECTRICAL DRAWINGS FIXTURE
CEILING MOUNTED RECESSED DOWN LIGHT
REFER TO ELECTRICAL DRAWINGS FIXTURE TYPE
EXTERIOR WALL MOUNTED LIGHT FIXTURE
REFER TO ELECTRICAL DRAWINGS FIXTURE
EXHAUST FAN SYSTEM REFER TO
MECHANICAL DRAWINGS FIXTURE
REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL
INFORMATION ON MECHANICAL LAYOUTS. REFER TO
ELECTRICAL DRAWINGS FOR ADDITIONAL
INFORMATION ON LIGHTING LAYOUTS.
ROOF ACCESS PANEL WITH ROOF
ACCESS LADDER
EMERGENCY LIGHT WITH 90 MINUTE BATTERY
BACKUP OR UNIT MOUNTED EMERGENCY
INVERTER. PROVIDE UNSWITCHED HOT WIRE
AS NOTED.
EXIT SIGN & LOW LEVEL EXIT SIGN
TACTILE EXIT SIGN SHALL BE REQUIRED
LIGHTED SURFACE
DIRECTIONAL ARROW
EXITS, EXIT ACCESS DOORS AND PATHS OF EGRESS
TRAVEL THAT IS NOT IMMEDIATELY VISIBLE TO THE
OCCUPANTS SHALL BE MARKED BY AN APPROVED
EXIT SIGN THAT IS READILY VISIBLE FROM ANY
DIRECTION OF EGRESS TRAVEL.
- EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY
ILLUMINATED.
-ADDITIONAL EXITS SIGNS MAY BE REQUIRED AT
TIME OF FIELD INSPECTION.
SUSPENDED CEILING GENERAL NOTES:
1
1
@13'-4" A.F.F.
SCALE: 1/4" = 1'-0"
2/28/2024 6:35:51 PM
17'-0"
SL
O
P
E
1/
4
"
:
1
2
SL
O
P
E
1/
4
"
:
1
2
SL
O
P
E
1/
4
"
:
1
2
10
'
-
0
"
10
'
-
0
"
10
'
-
0
"
10
'
-
0
"
17'-0"
2'-6"
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
DATE NO. DESCRIPTION
DRAWN BY:
DRAWING TITLE
SCALE:
SHEET NO.
REVISION
ACRC
AS SHOWN
unless they are sealed, signed and dated
not final and ready for use, and therefore not valid
As instruments of service, these documents are
of acceptance of these restrictions.
or specifications shall constitute conclusive evidence
of the Architect. Visual contact with these drawings
have been prepared, without the written consent
other than the specific project for which they
shall be reproduced or used for any purpose
property of the Architect and no part thereof
and arrangements represented thereby are the
These drawings, specifications, ideas, designs
5120 HAMNER AVE
# 140
EASTVALE, CA 91752
951.454.8801
PROJECT
DATE: FEB. 08, 2023
PLAN CHECK NO.
A
R
C
ESIGN
www.acrcdesigns.com
P.C. CORRECTION12/27/23
P.C. CORRECTION28/25/23
P.C. CORRECTION32/25/24
ROOF PLAN
A3ROOF PLAN
SCALE: 1/4" = 1'-0"
NO
R
T
H
ROOF PARAPET WALL
RTU
ROOF PLAN NOTES:
1. THE CONTRACTOR SHALL VERIFY LOCATION AND SIZE OF ALL
ROOF OPENINGS AND EQUIPMENT PLATFORMS REQUIRED.
2. REFER TO PLUMBING DRAWINGS FOR PLUMBING VENTS AND
PIPES THROUGH ROOF WHICH MAY NOT BE SHOWN ON THIS ROOF
PLAN. PROVIDE FLASHING AND COUNTER FLASHING AT MECHANICAL
EQUIPMENT CURBS AND TOILET VENTS.
3. REFER TO MECHANICAL DRAWINGS FOR HVAC, OPENINGS,
DUCTS AND VENTS THROUGH ROOF WHICH MAY NOT BE SHOWN ON
THIS ROOF PLAN.
5. ALL OPENINGS AT ROOF LARGER THAN 8" x 8" SHALL BE
PROTECTED WITH BURGLAR BARS PROVIDED AND INSTALLED BY
GENERAL CONTRACTOR. THE SPACING OF BARS SHALL NOT EXCEED 5" O.C.
6. ALL ROOF GUTTERS AND DOWNSPOUTS TO BE NON-COMBUSTIBLE MATERIAL
4. T.V. ANTENNA CROSS ARMS OR OTHER OBSTRUCTIONS
SHALL BE LOCATED 7'-0" MINIMUM ABOVE THE ROOF SURFACE.
CLASS 'A' CARLISLE 'SURE-WELD' TPO 60 MIL MEMBRANE
ROOF SYSTEM (WHITE) INSTALLED OVER 2 - 3 INCH LAYERS
OF POLYISOCYANURATE ROOF INSULATION LAID PERPENDICULAR
TO EACH OTHER (R-32 MIN. OR PER T-24 ENERGY CALC'S - SEE MECH'L)
OVER ROOF DECK PER STRUCTURAL PLANS
(SEE MECH)
ROOF PARAPET WALL
RTU
(SEE MECH)
RTU
(SEE MECH)
ROOF SKYLITE
TYP. OF 4
2 ROOF SKYLIGHT DETAIL
SCALE: N.T.S.
ROOF ACCESS HATCH AND LADDER BELOW.
SEE 16/A7.1 FOR DETAILS
ROOF DRAIN THRU WALL.
SEE 3 & 4/A7.1 TYP.
1
NOTE:
SKYCO SKYLIGHTS - DOUBLE DOME
VLT: 60% SHGC: 0.50 U-FACT: 0.50
ICC-ES LISTED - ESR-3837
1 1
1 1
1
1
1
1
DEFERRED SUBMITTAL
3PROVIDE 42" HIGH GUARD
2/28/2024 6:36:35 PM
10
'
-
0
"
F.F.
3'
-
4
"
4'
-
0
"
2'
-
0
"
4'
-
8
"
8'
-
0
"
10
'
-
0
"
3'
-
4
"
4'
-
0
"
6'
-
0
"
F.F.
8'
-
0
"
23
'
-
4
"
T.O.P.
T.O.P.
22
'
-
8
"
A D
24
'
-
0
"
10
'
-
0
"
F.F.
3'
-
4
"
24
'
-
0
"
T.O.P.
22
'
-
8
"
22
'
-
8
"
2'
-
0
"
3'
-
4
"
4'
-
0
"
6'
-
0
"
F.F.
23
'
-
4
"
T.O.P.
8'
-
0
"
10
'
-
0
"
F.F.
3'
-
4
"
4'
-
0
"
24
'
-
0
"
T.O.P.
8'
-
0
"
14
4'
-
0
"
2'
-
0
"
4'
-
8
"
2'
-
0
"
4'
-
8
"
90'-8"
7'
-
8
"
3'-8"
28 SF
139 SF
7'
-
8
"
28 SF7'
-
8
"
28 SF7'
-
8
"
3'-8"
28 SF7'
-
8
"
3'-8"3'-8"
7'
-
8
"
14'-10"
9'
-
5
"
20
'
-
0
"
BOTTOM OF ROOF
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
DATE NO. DESCRIPTION
DRAWN BY:
DRAWING TITLE
SCALE:
SHEET NO.
REVISION
ACRC
AS SHOWN
unless they are sealed, signed and dated
not final and ready for use, and therefore not valid
As instruments of service, these documents are
of acceptance of these restrictions.
or specifications shall constitute conclusive evidence
of the Architect. Visual contact with these drawings
have been prepared, without the written consent
other than the specific project for which they
shall be reproduced or used for any purpose
property of the Architect and no part thereof
and arrangements represented thereby are the
These drawings, specifications, ideas, designs
5120 HAMNER AVE
# 140
EASTVALE, CA 91752
951.454.8801
PROJECT
DATE: FEB. 08, 2023
PLAN CHECK NO.
A
R
C
ESIGN
www.acrcdesigns.com
P.C. CORRECTION12/27/23
P.C. CORRECTION28/25/23
P.C. CORRECTION32/25/24
EXTERIOR
ELEVATIONS
A4.1
EXTERIOR COLOR / MATERIALS:
2 EXTERIOR STUCCO
COLOR: DET 648 - WHITE PICKET FENCE
MANUFACTURER: DUNN EDWARDS
26 75
1 3
6 ALUMINUM STOREFRONT / WINDOW SYSTEM
EXTERIOR WALL MOUNTED LIGHT FIXTURE7
5 ALUMINUM AWNING
COLOR: DARK GRAY
COLOR: GRAY
PRECISION CONCRETE BLOCK
COLOR: BLACK 100 MW
MANUFACTURER: ORCO BLOCK
4
1
38
2 2
3 1 32 8 31
16 7261
1
COLOR: DET 570 - SMOKY BLUE
MANUFACTURER: DUNN EDWARDS
EXTERIOR STUCCO
3
3 EXTERIOR STUCCO
COLOR: DET 618 - INDUSTRIAL AGE
MANUFACTURER: DUNN EDWARDS
2
8 ALUMINUM SPANDREL GLASS
6 8 6
2
NORTH EXTERIOR ELEVATION AT LA PORTE STREET
SCALE: 1/4" = 1'-0"
EAST EXTERIOR ELEVATION
SCALE: 1/4" = 1'-0"
EAST FACING FACADE TOTAL AREA:
90'-8" X 20'-0" = 1,813 SF
(EXCLUDE SPANDREL GLASS)
EAST FACING WINDOW OPENINGS
28 SF x 4 = 112 SF
139 SF x 1 = 139 SF
TOTAL GLASS OPENING AREA = 251 SF (13.8%)
MAX. WINDOW OPENING RATIO 15%
1
1
13
A7.1
13
A7.1
2
2
2/28/2024 6:37:17 PM
10
'
-
0
"
F.F.
3'
-
4
"
24
'
-
0
"
T.O.P.
8'
-
0
"
10
'
-
0
"
3'
-
4
"
4'
-
0
"
6'
-
0
"
F.F.
8'
-
0
"
23
'
-
4
"
T.O.P.
D A
4'
-
0
"
2'
-
0
"
4'
-
8
"
23
'
-
4
"
F.F.
T.O.P.
23
'
-
4
"
F.F.
T.O.P.
1 4
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
DATE NO. DESCRIPTION
DRAWN BY:
DRAWING TITLE
SCALE:
SHEET NO.
REVISION
ACRC
AS SHOWN
unless they are sealed, signed and dated
not final and ready for use, and therefore not valid
As instruments of service, these documents are
of acceptance of these restrictions.
or specifications shall constitute conclusive evidence
of the Architect. Visual contact with these drawings
have been prepared, without the written consent
other than the specific project for which they
shall be reproduced or used for any purpose
property of the Architect and no part thereof
and arrangements represented thereby are the
These drawings, specifications, ideas, designs
5120 HAMNER AVE
# 140
EASTVALE, CA 91752
951.454.8801
PROJECT
DATE: FEB. 08, 2023
PLAN CHECK NO.
A
R
C
ESIGN
www.acrcdesigns.com
P.C. CORRECTION12/27/23
P.C. CORRECTION28/25/23
P.C. CORRECTION32/25/24
EXTERIOR
ELEVATIONS
A4.2
EXTERIOR COLOR / MATERIALS:
2 EXTERIOR STUCCO
COLOR: DET 648 - WHITE PICKET FENCE
MANUFACTURER: DUNN EDWARDS
6 ALUMINUM STOREFRONT / WINDOW SYSTEM
EXTERIOR WALL MOUNTED LIGHT FIXTURE7
5 ALUMINUM AWNING
COLOR: DARK GRAY
COLOR: GRAY
PRECISION CONCRETE BLOCK
COLOR: BLACK 100 MW
MANUFACTURER: ORCO BLOCK
41
COLOR: DET 570 - SMOKY BLUE
MANUFACTURER: DUNN EDWARDS
EXTERIOR STUCCO
3 EXTERIOR STUCCO
COLOR: DET 618 - INDUSTRIAL AGE
MANUFACTURER: DUNN EDWARDS75
2
1
6 3
2
1
4 2
4
3
3
6
WEST EXTERIOR ELEVATION
SCALE: 1/4" = 1'-0"
SOUTH (REAR) EXTERIOR ELEVATION
SCALE: 1/4" = 1'-0"
8 ALUMINUM SPANDREL GLASS
1
13
A7.1
2
13
A7.1
2
2/28/2024 6:37:53 PM
4'
-
0
"
10
'
-
0
"
T.O.P.
3'
-
4
"
F.F.
20
'
-
0
"
12
'
-
0
"
T.O.P.
F.F.
23
'
-
4
"
6'
-
8
"
24
'
-
0
"
3'
-
4
"
T.O.P.
F.F.
23
'
-
4
"
4'
-
0
"
10
'
-
0
"
T.O.P.
3'
-
4
"
F.F.
6'
-
8
"
24
'
-
0
"
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
DATE NO. DESCRIPTION
DRAWN BY:
DRAWING TITLE
SCALE:
SHEET NO.
REVISION
ACRC
AS SHOWN
unless they are sealed, signed and dated
not final and ready for use, and therefore not valid
As instruments of service, these documents are
of acceptance of these restrictions.
or specifications shall constitute conclusive evidence
of the Architect. Visual contact with these drawings
have been prepared, without the written consent
other than the specific project for which they
shall be reproduced or used for any purpose
property of the Architect and no part thereof
and arrangements represented thereby are the
These drawings, specifications, ideas, designs
5120 HAMNER AVE
# 140
EASTVALE, CA 91752
951.454.8801
PROJECT
DATE: FEB. 08, 2023
PLAN CHECK NO.
A
R
C
ESIGN
www.acrcdesigns.com
P.C. CORRECTION12/27/23
P.C. CORRECTION28/25/23
P.C. CORRECTION32/25/24
BUILDING
SECTIONS
A5
4
1
2
5
6
SECTION KEYNOTES
ALUMINUM STOREFRONT DOOR / WINDOW SYSTEM
4
1
A7.2
FIRE RESISTANT 12" CMU WALL (SEE STRUCTURAL DRAWING)
& EXTERIOR CEMENT PLASTER ON THE EXTERIOR SURFACE
NON-RATED INTERIOR PARTITION: (SEE STRUCTURAL DRAWING)
OF SPECIFIED WALLBOARD (ON RESTROOM SIDE)
* USE WATER RESISTENT GYPSUM BOARD IN LIEU
1 5/8" x 6", 18 GA. METAL STUD @ 16" O.C.
WITH 5/8" TYPE 'X' GYPSUM BOARDS ON BOTH SIDES
OF SPECIFIED WALLBOARD (ON RESTROOM SIDE)
* USE WATER RESISTENT GYPSUM BOARD IN LIEU
1 1/2 x 3 1/2, 20 GA. METAL STUD @ 16" O.C.
WITH 5/8" GYPSUM BOARDS ON BOTH SIDES
FIRE RATED INTERIOR PARTITION: (SEE STRUCTURAL DRAWING)
3
CLASS 'A' CARLISLE 'SURE-WELD' TPO 60 MIL MEMBRANE
ROOF SYSTEM (WHITE) INSTALLED OVER 2 - 3 INCH LAYERS
OF POLYISOCYANURATE ROOF INSULATION LAID PERPENDICULAR
TO EACH OTHER (R-32 MIN. OR PER T-24 ENERGY CALC'S - SEE MECH'L)
OVER ROOF DECK PER STRUCTURAL PLANS
w/ FLUSH MOUNTED FLUORESCENT LIGHT FIXTURES
2'x2' SUSPENDED ACOUSTICAL TILE CEILING PANEL
7 CONCRETE SLAB - SEE CIVIL / STRUCTURAL DRAWINGS
8 ROOF TOP MECHANICAL UNIT & PLATFORM (SEE MECH. DWG.)
REFLECTED CEILING PLAN
SCALE: 1/4" = 1'-0"
9 ALUMINUM AWNING - SEE MANUFACTURER SPEC.
1
1
1
1
2
3
3
4
11
5
5
5
6
7
7
8
9
9 9
10 HIGH-LIFT GARAGE DOOR - (SEE MANUFACTURER SPEC.)
10
11 ALUMINUM SPANDREL WINDOW SYSTEM
1
CEILING JOISTS
SEE STRUCTURAL FOR
CEILING JOISTS
SEE STRUCTURAL FOR
2/28/2024 6:38:23 PM
A
WINDOW TYPE
DOOR TYPE
DOOR SCHEDULE
MATERIAL
EXTERIOR ENTRY DOOR
SIZE
NO
1
WIDTH HEIGHT THKNS.
GLASSLOCATION TYPE MATERIAL
DOOR
FIREFINISHRATING
FRAME
FIN. FLR.
4
a d
2
WINDOW SCHEDULE
MATERIAL
SIZE
NO
WIDTH HEIGHT
LOCATION TYPE
WINDOW FRAME
FINISH
GLAZING
A
MATERIALTYPEGLASSTHKNS.
a
3
3'-0"
7'
-
0
"
ALUMN WD PTD4 1/2"
b c
REGULATIONS, WHERE WINDOW IS WITHIN 12" OF A DOOR, AND
JAMB, AND SILL DETAILS.
APPROVED FLASHING.
WITH AMERICAN NATIONAL STANDARD INSTITUTE STANDARDS.
6. WINDOWS SHALL BE CERTIFIED AND LABELED IN COMPLIANCE
5. FLASH AROUND ALL EXTERIOR WINDOW OPENINGS WITH
11. ALL WINDOWS TO HAVE INSECT SCREENS AT SLIDING
12. WINDOWS AND FRAMES COLOR AND FINISH PER OWNER
PANEL LOCATION.
WINDOW NOTES
2019 CBC, CHAPTER 24, AND 16 CFR 1201 SAFETY STANDARDS WINDOW OPENING AND FIELD ROUGH DIMENSIONS.
FOR ARCHITECTURAL GLAZING MATERIALS.
3. ALL ALUMINUM SASH TO COMPLY WITH THE AAMA STANDARDS.
4. T INDICATES GLASS TO BE TEMPERED PER ABOVE MENTIONED
9. ALL WINDOW FRAMES TO BE PAINTED WITH SILICONE
DRAWINGS TO INCLUDE (BUT NOT LIMITED TO) HEAD,
DETAILED SHOP DRAWINGS PRIOR TO FABRICATION.
10. WINDOW CONTRACTOR TO PROVIDE ARCHITECT WITH
POLYESTER COATING, COLOR BY ARCHITECT.
1. ALL WINDOW ELEVATIONS BELOW WERE DRAWN AS VIEWED
2. ALL GLASS AND GLAZING TO BE IN ACCORDANCE WITH THE 8. FRAMING CONTRACTOR TO VERIFY MANUFACTURER'S ROUGH
ALUMINUM.
7. UNLESS OTHERWISE NOTED, ALL WINDOWS FRAMES TO BE FROM EXTERIOR SIDE AT A SCALE OF 3/16" = 1'-0".
4. ALL EXTERIOR STEEL FRAMES TO BE GALVANIZED,
6. ALL LOCKS ARE TO BE MASTERKEYED AS PER THE OWNER'S
5. DOORS SHALL BE SCRIBED AND PRE-CUT WITH THE EXACT
7. FIELD MEASURE ALL THE DOOR OPENINGS PRIOR TO FABRICATION.
CLEARANCE ABOVE SLAB AS REQUIRED BY FLOOR FINISHES.
NATIONAL STANDARD INSTITUTE STANDARDS. CERTIFIED AND LABELED AS MEETING WITH THE AMERICAN
3. ALL MANUFACTURED EXTERIOR DOOR UNITS SHALL BE
AROUND EXTERIOR DOORS AND WINDOWS; SEE TITLE 24. 2. PROVIDE WEATHERSTRIPPING AND FLASHING COMPLETELY
FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO
TRAP OR HAZARDOUS CONDITION. WHERE NARROW FRAME
DOORS ARE USED, A TEN (10) INCH HIGH SMOOTH PANEL
HAZARDOUS CONDITION.
THRESHOLDS SHALL NOT EXCEED 1/2" INCH IN HEIGHT.
WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR WHICH WILL ALLOW THE DOOR TO BE OPENED BY A
SHALL BE INSTALLED ON THE PUSH SIDE OF THE DOOR,
FIFTEEN (15) POUNDS. OPERATE THE DOOR MAY BE INCREASED NOT TO EXCEED
OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A
UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH
THE BOTTOM TEN (10) INCHES OF ALL EXIT DOORS
MAXIMUM EFFORT TO OPERATE EXIT DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS
BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND
FOR INTERIOR DOORS. SUCH PULL AND PUSH EFFORT
MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS
AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS.
GENERAL NOTES
1. HAND ACTIVATED DOOR OPENING HARDWARE MOUNTING AND
HANDICAPPED CODE. OPERATIONAL TYPE SHALL BE IN ACCORDANCE WITH THE
IN DOORS AND ENCLOSURE FOR HOT TUB, BATHTUB, SHOWERS
(ALSO GLAZING IN WALL ENCLOSING THESE COMPARTMENTS
WITHIN 5' OF STANDING SURFACE)
8. APPROVED SHATTER-RESISTANT MATERIALS FOR SHOWER ENCLOSURE.
REMARK
3'-0"
8'
-
0
"
3'-0"
FIN. FLR.
D
E
ALUMN15'-0"10'-0"PTD GLDBL GLAZED CLEAR3/8"
8'-0"
FIXED
15'-0"4'-0"PTD GLDBL GLAZED CLEAR3/8"FIXED
4'-0"8'-0"WAREHOUSE PTD GLDBL GLAZED CLEAR3/8"FIXED
PTD GLDBL GLAZED CLEAR3/8"FIXED
B
C
4'-0"PTD GLDBL GLAZED CLEAR3/8"FIXED
A
D
E
B
C
SWING TEMPERED
INTERIOR DOOR b WD PTD3'-0"7'-0"SWING
UNLESS OTHERWISE NOTED.
INSTRUCTIONS.
3'-0"
7'
-
0
"
RESTROOM c WD PTD3'-0"7'-0"SWINGSC 1 3/4"
PER CBC SEC. 1011.3 & 1117B.5, TACTILE EXIT SIGNS SHALL BE
POSTED AT THE LOCATIONS INDICATED:
1. EACH GRADE LEVEL EXTERIOR EXIT DOOR SHALL HAVE A
TACTILE SIGN WITH THE WORD "EXIT";
2. EACH STAIRWAY DOOR THAT LEADS TO A GRADE LEVEL
EXTERIOR EXIT DOOR SHALL HAVE A TACTILE EXIT SIGN WITH
EITHER "EXIT STAIR DOWN" OR "EXIT STAIR UP" AS
APPROPRIATE;
3. EACH EXIT ACCESS FROM AN INTERIOR AREA THAT IS
REQUIRED TO HAVE A VISUAL EXIT SHALL BE IDENTIFIED BY
A TACTILE EXIT SIGN WITH THE WORDS "EXIT ROUTE'.
INTERNAT'L SYMBOL OF
@ ACCESSIBLE ENTRANCE
DOORS (LATCH SIDE)
ACCESSIBILITY SIGN WITH
CLASS 2 BRAILLE PER CBC 11B-703
MOUNTED AT 60" ABOVE FIN. FLR.
EXIT
LEVER LOCKSET
SOLID CORE DOOR
KICKPLATE
AT EXIT DOORS POST
ACCESSIBILITY WITH CLASS 2
NOTES:
3'-0"
8'
-
0
"
SEE SCHED
TEMP
SC 1 3/4"
WAREHOUSE d ALUMN WD PTD2"10'-0"8'-0"ROLL-UP TEMPERED
TEMP TEMP TEMP TEMPTEMP
5'
-
0
"
3'
-
0
"
2'
-
0
"
10
'
-
0
"
8'
-
0
"
OF ACCESSIBILITY AT ALL ENTRANCE DOOR
THE SIGN SHALL BE LOCATED
THE DOOR AND RIGHT SIDE OF
PROVIDE AN INTERNATIONAL SYMBOL
ADJACENT TO THE LATCH SIDE OF
THE DOUBLE DOOR 60" O.C. A.F.F.
5'
-
0
"
6'-0"3'-0"6'-0"
15'-0"
15'-0"
B
1
OF ACCESSIBILITY AT ALL ENTRANCE DOOR
THE SIGN SHALL BE LOCATED
THE DOOR AND RIGHT SIDE OF
PROVIDE AN INTERNATIONAL SYMBOL
ADJACENT TO THE LATCH SIDE OF
THE DOUBLE DOOR 60" O.C. A.F.F.
5'
-
0
"
C
8'
-
0
"
4'-0"
D E
EXTERIOR ENTRY - UNIT 'A'
EXTERIOR ENTRY - UNIT 'A'ALUMN
WAREHOUSE
WAREHOUSE
ALUMN
ALUMN
ALUMN
5 WAREHOUSE d ALUMN WD PTD2"8'-0"8'-0"ROLL-UP TEMPERED
3'-0"6'-0"
F
F 4'-0"PTD GLDBL GLAZED CLEAR3/8"FIXEDF 6'-0"WAREHOUSE ALUMN
4'
-
0
"
4'-0"
G
G 4'-0"PTD GLDBL GLAZED CLEAR1/4"FIXEDG 4'-0"
4'
-
0
"
4'
-
0
"
4'
-
0
"
10" KICKPLATE10
"
TEMP
TEMP TEMP
U-VALUE
0.55
TEMP
SPANDREL GLASS
15'-0"
4'
-
0
"
(SPANDREL GLASS FACING TO EAST ELEVATION)
WAREHOUSE ALUMN
15'-0"4'-0"
0.55
0.55
0.55
0.55
0.55
0.55
TEMP TEMP TEMP TEMP
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
DATE NO. DESCRIPTION
DRAWN BY:
DRAWING TITLE
SCALE:
SHEET NO.
REVISION
ACRC
AS SHOWN
unless they are sealed, signed and dated
not final and ready for use, and therefore not valid
As instruments of service, these documents are
of acceptance of these restrictions.
or specifications shall constitute conclusive evidence
of the Architect. Visual contact with these drawings
have been prepared, without the written consent
other than the specific project for which they
shall be reproduced or used for any purpose
property of the Architect and no part thereof
and arrangements represented thereby are the
These drawings, specifications, ideas, designs
5120 HAMNER AVE
# 140
EASTVALE, CA 91752
951.454.8801
PROJECT
DATE: FEB. 08, 2023
PLAN CHECK NO.
A
R
C
ESIGN
www.acrcdesigns.com
P.C. CORRECTION12/27/23
P.C. CORRECTION28/25/23
P.C. CORRECTION32/25/24
DOOR AND
WINDOW
SCHEDULES
A6.1
NOTE:
LIGHT STANDARDS SHALL BE A MAXIMUM 20 FEET IN HEIGHT. THE HEIGHT OF THE LIGHT STANDARD SHALL BE
MEASURED FROM THE ELEVATION OF THE ADJACENT PAVEMENT OF THE PARKING LOT. WHEN THE SUBJECT
PROPERTY ABUTS A RESIDENTIALLY ZONED PROPERTY OR IS WITHIN 100 FEET OF RESIDENTIALLY ZONED PROPERTY,
LIGHT STANDARDS WITH 100 FEET OF THE PROPERTY SHALL NOT EXCEED 15 FEET IN HEIGHT.
20'-0"
1
2
2/28/2024 6:38:59 PM
2. SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE APPLICATION OF A 250 LB. POINT
LOAD SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS FOR THE MATERIAL
OF THE GRAB BAR OR SEAT, AND ITS MOUNTING BRACKET OR OTHER SUPPORT
IS CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT AND TORSIONAL SHEAR
STRESS SHALL NOT EXCEED THE ALLOWABLE SHEAR STRESS.
6. A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE
FREE OF ANY SHARP OR ABRASIVE ELEMENTS. EDGES SHALL HAVE A MINIMUM
RADIUS OF 1/8".
3. SHEAR FORCE INDUCED IN FASTENERS OR MOUNTING DEVICES FROM THE
APPLICATION OF A 250 LB. POINT LOAD SHALL BE LESS THAN THE ALLOWABLE
LATERAL LOAD OF EITHER THE FASTENER OR MOUNTING DEVICE OR THE
SUPPORTING STRUCTURE, WHICHEVER HAS THE SMALLER ALLOWABLE LOAD.
THE STRUCTURAL STRENGTH OF GRAB BARS, FASTENERS AND MOUNTING
DEVICES SHALL MEET THE FOLOWING SPECIFICATIONS :
1. BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THE MAXIMUM BENDING
MOMENT FROM THE APPLICATION OF A 250 LB. POINT LOAD SHALL LESS THAN THE
ALLOWABLE STRESS FOR THE MATERIAL OF THE GRAB BAR OR SEAT.
4. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF A
250 LB. PONT LOAD, PLUS THE MAXIMUM MOMENT FROM THE APPLICATION
OF A 250 LB. POINT LOAD, SHALL BE LESS THAN THE FASTENER AND
SUPPORTING STRUCTURE.
5. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
GRAB BAR NOTES :
40
"
M
A
X
19
"
M
I
N
112"Ø GRAB BAR W/ PEENED FINISH 1. ALL TOILET ROOMS SHALL COMPLY WITH ALL REQUIREMENTS OF THE CURRENT
CALIFORNIA TITLE 24 OR FEDERAL ADA AG REQUIREMENTS.
2. DRAIN AND HOT PIPES UNDER THE LAVATORIES SHALL BE INSULATED TO
PREVENT A PERSON WITHOUT SENSATION IN A WHEELCHAIR FROM BEING BURNED.
3. INSTALL 1 1
2" DIAMETER CHROME-FINISH GRAB BARS WITH 1 1
2" CLEARANCE
BETWEEN GRAB BARS AND WALL. GRAB BARS SHALL BE MOUNTED 33" FROM THE
FINISHED FLOOR TO THE CENTER OF THE GRAB BAR ABOVE AND PARALLEL TO THE FLOOR.
4. ALL TOILET ROOMS SHALL BE PROVIDED WITH A MECHANICAL VENTILATING
SYSTEM TO PROVIDE ONE (I) COMPLETE CHANGE OF AIR EVERY FIFTEEN (15)
MINUTES AND CONNECTED TO THE LIGHT SWITCH.
5. DOORS TO HANDICAPPED WATER CLOSET COMPARTMENTS SHALL BE
SELF-CLOSING, PER CURRENT CBC REQUIREMENTS.
6. FAUCET CONTROLS SHALL BE OPERABLE WITH ONE HAND AND 5 LBS.
PRESSURE, PER CURRENT CBC REQUIREMENTS.
7. LOW CONSUMPTION WATER CLOSETS SHALL BE INSTALLED, SEE PLUMBING DRAWINGS.
8. DOORWAYS LEADING TO UNISEX TOILET ROOM SHALL BE IDENTIFIED BY AN 12"
DIAMETER CIRCLE WITH EQUILATERAL TRIANGLE SUPERIMPOS ED ON THE CIRCLE,
REFER TO DETAILS FOR ADDITIONAL INFORMATION.
9. GEOMETRIC (CIRCLE AND TRIANGLE) SYMBOLS ON TOILET ROOM DOORS SHALL BE
CENTERED ON THE DOOR AT A HEIGHT OF 60" AND THEIR COLOR AND CONTRAST
SHALL BE DISTINCTLY DIFFERENT FROM THE COLOR AND CONTRAST OF THE DOOR.
10. EXCEPT FOR DOOR OPENING WIDTH AND DOOR SWING, A CLEAR, UNOBSTRUCTED
ACCESS NOT LESS THAN 44" SHALL BE PROVIDED TO WATER CLOSET COMPARTMENT
DESIGNED FOR USE BY PERSONS WITH DISABILITIES AND THE SPACE IMMEDIATELY IN
FRONT OF WATER CLOSET COMPARTMENT SHALL BE NOT LESS THAN 48" AS MEASURED AT
RIGHT ANGLE TO COMPARTMENT DOOR IN ITS CLOSED POSITION.
11. WATER CLOSETS FLUSH VALVE CONTROLS, AND FAUCET AND OPERATING
MECHANISM CONTROLS, SHALL BE OPERABLE WITH ONE HAND, SHALL NOT
REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST, AND SHALL
BE MOUNTED NO MORE THAN 44" ABOVE THE FLOOR.
12. INSTALL WATER CLOSET TANK WITH FLUSH VALVE ON WIDE SIDE OF TOILET AREA OR COMPARTMENT.
13. THE KNEE CLEARANCE UNDER THE FRONT LIP OF THE LAVATORY EXTENDING A MIN. OF
30" IN WIDTH AND 8" MINIMUM DEPTH AT TOP. TOE CLEARING SHALL BE THE SAME WIDTH
AND SHALL BE A MINIMUM OF 9" HIGH FROM THE FLOOR AND A MINIMUM OF 17" DEEP FROM
THE FRONT OF THE LAVATORY.
33
"
36" MAX
12" MAX
19
"
M
I
N
TYP. SIDE ELEVATION
cL
42" MIN
TO
I
L
E
T
PA
P
E
R
17" MIN- 18" MAX
17
"
-
1
9
"
TYP. FRONT ELEVATION
cL
36"4"
36
"
M
A
X
I
M
U
M
36" MAXIMUM
17
"
T
O
1
9
"
T
O
T
O
P
OF
T
O
I
L
E
T
S
E
A
T
ROLL PAPER HOLDER WITHOUT STOPS
TOILET SEAT DISPENSER
24"
7" MIN-9" MAX
8" MIN
17" MIN
6"MAX
29
"
M
I
N
34
"
M
A
X
27
"
M
I
N
9"
M
I
N
40
"
M
A
X
KNEE CLEARANCE TOE CLEARANCE
FINISH NOTES:
1. ALL TOILET ROOMS FLOOR SHALL BE CERAMIC TILE
2. ALL TOILET ROOMS BASE SHALL BE CERAMIC TILE BASE, TO MATCH THE WALL TILE
3. ALL TOILET ROOMS WALLS SHALL BE CERAMIC TILE
4. ALL TOILET ROOMS CEILING SHALL BE SEMI-GLOSS PAINT
5. ALL TOILET ROOMS DOOR AND FRAMES SHALL BE PAINTED WITH SATIN ENAMEL
6. ALL GYPSUM BOARD WALLS HAVE "ORANGE PEEL" TEXTURE.
7. ALL EXPOSED CONCRETE SHALL BE SEALED.
MOUNTING DIMENSIONS
2.
1.
ACCESSIBILITY TOILET ROOM SIGNAGE NOTES:
3.
4.CHARACTERS AND SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE
LATCH SIDE OF THE DOOR.
FINISH CONTRAST - THE CHARACTERS AND BACKGROUND OF SIGNS SHALL BE
EGGSHELL, MATTE, OR OTHER NON-GLARE FINISH. BACKGROUND COLOR OF SIGNS
SHALL CONTRAST WITH DOOR OR WALL COLOR.
ROOM SIGN - RAISED AND BRAILLED CHARACTERS AND PICTORIAL SYMBOL SIGNS
(PICTOGRAMS). LETTERS AND NUMERALS SHALL BE RAISED 1/32 " UPPER CASE,
SANS-SERIF OR SIMPLE SERIF TYPE AND SHALL BE ACCOMPANIED BY GRADE 2 BRAILLE.
RAISED CHARACTERS SHALL BE AT LEAST 5/8 " HIGH, BUT NO HIGHER THAN 2".
DOOR SIGN - SHALL BE CENTERED ON DOOR AND MOUNTED (WITH ADHESIVE ONLY & CAULK
EDGES WITH CLEAR SILICON) 60" ABOVE THE FLOOR AT THE CENTER OF THE SIGN.
14. WHERE A WATER CLOSET IS NOT WITHIN A WATER CLOSET COMPARTMENT, CLEAR FLOOR
SPACE AROUND THE WATER CLOSET SHALL BE 60 INCHES MINIMUM MEASURED PERPENDICULAR
FROM THE SIDE WALL CLOSEST TO THE WATER CLOSET AND 56 INCHES MINIMUM MEASURED
PERPENDICULAR FROM THE REAR WALL.
TOILET ROOM NOTES:
OOM
CLEAR OF DOOR SWING, MOUNT AT
BE LOCATED ON LATCH SIDE OF DOOR
WALL MOUNTED ALL-GENDER SIGNAGE TO
CORRESPONDING GRADE 11 BRAILLE
TO 2" MAX.LETTERING RAISED 1/32"
UPPER CASE CHARACTERS
HEIGHT OF LETTERING 5/8" MIN.
WHITE SYMBOLS ON BLUE BACKGROUND
60" TO CENTERLINE OF SIGN FROM FLOOR.
DOOR MOUNTED ALL-GENDER SIGNAGE OF
CONTRASTING COLOR TO DOOR, w/ INTERNATIONAL
CL
12
"
F.F.
60
"
THE CIRCLE
SUPERIMPOSED ON
TRIANGLE (1/4" THICK)
EQUILATERAL
UNISEX:-ALL-GENDER
EQUILATERAL
12" SIDES
TRIANGLE WITH CIRCLE
12" DIAMETER
WOMEN:MEN:
(1/4" THICK) WITH
12" DIAMETER CIRCLE
TO COLOR NO. 15090 IN FEDERAL STANDARD 595B
1/4" THICK ACRYLIC, BLUE COLOR EQUAL
MATERIAL:
12
"
12
"12"
HOT WATER AND DRAIN PIPES UNDER LAVATORY SHALL BE INSULATED OR
OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO
SHARP OR ABRASIVE SURFACES UNDER LAVATORIES.
RESTROOM
RESTROOM SYMBOL OF ACCESSIBILITY, PER CBC 11B-216.8
CBC 11B-604.2
7'
-
0
"
3'-0" CLR
L INTERNAT'L SYMBOL OF ACCESSIBILITY WITH
CLASS 2 BRAILLE @ ACCESSIBLE ENTRANCE
DOORS (LATCH SIDE)
AT EXIT DOORS POST ACCESSIBILITY SIGN WITH
CLASS 2 BRAILLE PER CBC 11B-703 MTD. AT 60"
ABOVE FIN. FLR.
EXIT
C OF
BRAILLE
LEVER LOCKSET
SOLID CORE DOOR
KICKPLATE
TYP. SIDE ELEVATION
AND 250 LBS. CAPACITY
15. TOILET TISSUE DISPENSERS SHALL BE LOCATED WITHIN 7" TO 9" MEASURED FROM THE
FRONT OF THE BOWL TO THE CENTERLINE OF THE TOILET PAPER DISPENSER
MOUNTED BELOW THE GRAB BAR AT A MINIMUM HEIGHT OF 19" AND 36" MAXIMUM TO
THE FAR EDGE FROM THE REAR WALL.
16. ALL SINGLE ACCOMMODATION RESTROOMS MUST BE IDENTIFIED AS ALL-GENDER
TOILET FACILITIES.
17. ALL NON-COMPLIANT PLUMBING FIXTURES WITHIN THIS BUILDING SHALL BE REPLACED
WITH WATER-CONSERVING PLUMBING FIXTURES.
18
"
18
"
5'-4"5'-4"
8'-0"8'-0"
8'
-
0
"
8'
-
0
"
18
"
18
"
56"
60
"
56"
60
"
18
"
18
"
5'-4"
8'-0"
8'
-
0
"
56"
60
"
2'-0"
33
"
5'
-
0
"
8'
-
0
"
5'
-
0
"
8'
-
0
"
2'
-
1
0
"
29
"
M
I
N
.
40
"
M
A
X
.
9"5'
-
0
"
8'
-
0
"
17
"
-
1
9
"
33
"
19
"
M
I
N
.
2'
-
1
0
"
29
"
M
I
N
.
40
"
M
A
X
.
17
"
-
1
9
"
33
"
19
"
M
I
N
.
2'-
1
0
"
29
"
M
I
N
.
40
"
M
A
X
.
2'-0"
33
"
5'-
0
"
8'-
0
"
5'-
0
"
8'-
0
"
2'-
1
0
"
29
"
M
I
N
.
40
"
M
A
X
.
9"
8'-
0
"
5'-
0
"
2'-0"
33
"
5'
-
0
"
8'
-
0
"
2'
-
1
0
"
29
"
M
I
N
.
40
"
M
A
X
.
9"5'
-
0
"
8'
-
0
"
17
"
-
1
9
"
33
"
19
"
M
I
N
.
2'
-
1
0
"
29
"
M
I
N
.
40
"
M
A
X
.
5'
-
0
"
8'
-
0
"
18
"
18
"
5'-4"
8'-0"
8'
-
0
"
56"
60
"
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
DATE NO. DESCRIPTION
DRAWN BY:
DRAWING TITLE
SCALE:
SHEET NO.
REVISION
ACRC
AS SHOWN
unless they are sealed, signed and dated
not final and ready for use, and therefore not valid
As instruments of service, these documents are
of acceptance of these restrictions.
or specifications shall constitute conclusive evidence
of the Architect. Visual contact with these drawings
have been prepared, without the written consent
other than the specific project for which they
shall be reproduced or used for any purpose
property of the Architect and no part thereof
and arrangements represented thereby are the
These drawings, specifications, ideas, designs
5120 HAMNER AVE
# 140
EASTVALE, CA 91752
951.454.8801
PROJECT
DATE: FEB. 08, 2023
PLAN CHECK NO.
A
R
C
ESIGN
www.acrcdesigns.com
P.C. CORRECTION12/27/23
P.C. CORRECTION28/25/23
P.C. CORRECTION32/25/24
ENLARGED
RESTROOM
PLAN
A6.2
KEYNOTES:
1
2 LAVATORY PROTECT HOT WATER & DRAIN PIPES WITH
3
4
5
6
TOILET PAPER HOLDER
7
8
WALL MOUNTED MIRROR - TYPICAL
STEEL GRAB BAR - TYPICAL
5'-0" MIN. WHEELCHAIR TURNAROUND
ACCESSIBLE WATER CLOSET. 1.6 GALLON MAX. PER FLUSH,
(MAX. 5 LB FLUSH CONTROL OPERATION LOCATED
HAND AND MAX. OF 5 LB FORCE REQUIRED TO OPERATE)
TO BE PAINTED WITH GLOSS ENAMEL ALL WALLS SHALL
HAVE A SMOOTH & NON-ABSORBENT FINISH.
OR OTHER APPROVED MATERIAL THAT EXTENDS UPWARD
ONTO THE WALL, AT LEAST 5 INCHES.
IDENTIFICATION SYMBOLS FOR SANITARY FACILITIES. 9
INT. ELEVATION
SCALE: 1/4" = 1'-0"
INT. ELEVATION
SCALE: 1/4" = 1'-0"
INT. ELEVATION
SCALE: 1/4" = 1'-0"
INT. ELEVATION
SCALE: 1/4" = 1'-0"
RESTROOM PLAN
SCALE: 1/4" = 1'-0"
TOILET FLUSH CONTROL MOUNTED ON WIDE SIDE.
INT. ELEVATION
SCALE: 1/4" = 1'-0"
INT. ELEVATION
SCALE: 1/4" = 1'-0"
INT. ELEVATION
SCALE: 1/4" = 1'-0"
INT. ELEVATION
SCALE: 1/4" = 1'-0"
INT. ELEVATION
SCALE: 1/4" = 1'-0"
INT. ELEVATION
SCALE: 1/4" = 1'-0"
INT. ELEVATION
SCALE: 1/4" = 1'-0"
INT. ELEVATION
SCALE: 1/4" = 1'-0"
FLOORS SHALL HAVE A SMOOTH HARD NON-ABSORBENT
SURFACE, SUCH AS PORTLAND CEMENT, CERAMIC TILE
NON-ABSORBENT CERAMIC TILE OVER 5/8" W.R. GYP. BD.
TO A HEIGHT OF 60" ABV. FINISHED FLOOR, WALL ABOVE
INSULATION. (FAUCET CONTROLS OPERABLE WITH ONE
MAX. 44" ABOVE FIN. FLR.)
RESTROOM PLAN
SCALE: 1/4" = 1'-0"
3
4
5
6
7
8
9
1011
12
13
14
11
1
1 1
1 1
11
2
22
2 2
2 2
2 2
3
3
3
4
4
4
55
5 5
5 5
6
6
6
7 7 7 7
7 7 7 7
7 7 7 7
8 8 8 8
8 8 8 8
8 8 8 8
99
9
9
9
9
1
4 356
12 11
8 7
213
9
14
10
56"x60" CLEARANCE AT WATER CLOSET10
1010
10
3
3
3
2/28/2024 6:39:31 PM
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
DATE NO. DESCRIPTION
DRAWN BY:
DRAWING TITLE
SCALE:
SHEET NO.
REVISION
ACRC
AS SHOWN
unless they are sealed, signed and dated
not final and ready for use, and therefore not valid
As instruments of service, these documents are
of acceptance of these restrictions.
or specifications shall constitute conclusive evidence
of the Architect. Visual contact with these drawings
have been prepared, without the written consent
other than the specific project for which they
shall be reproduced or used for any purpose
property of the Architect and no part thereof
and arrangements represented thereby are the
These drawings, specifications, ideas, designs
5120 HAMNER AVE
# 140
EASTVALE, CA 91752
951.454.8801
PROJECT
DATE: FEB. 08, 2023
PLAN CHECK NO.
A
R
C
ESIGN
www.acrcdesigns.com
P.C. CORRECTION12/27/23
P.C. CORRECTION28/25/23
P.C. CORRECTION32/25/24
ARCHITECTURAL
DETAILS
A7.1
ROOF DRAIN & OVERFLOW
SCALE: N.T.S.
PARAPET WALL AT ROOF
SCALE: N.T.S.
ROOF DRAINAGE
SCALE: N.T.S.
SCALE: N.T.S.
SCUPPER AT ROOF
SCALE: N.T.S.
1'-
6
"
PARAPET
1'-0"
ROOF DRAIN
4
4
6'-0" X 3'-0" WELL (VERIFY)
MIN. 6" ROUND ROOF DRAIN
WITH GALVANIZED CAST IRON
PROVIDE GALV. MTL.
SUMP RECEIVER
SEE PLUMBING SPECIFICATIONS FOR ADDITIONAL INFORMATION.
ROOFING CONTRACTOR TO INSTALL 4 LB LEAD SHEET OVER COMPLETED
ROOF MEMBRANE AND STRIPPED IN PRIOR TO FINIAL SURFACING.
2'-6"
SLOPE OF ROOF BEYOND
OVERFLOW SYSTEM INLETS SHALL BE LOCATED 2" ABOVE LOW POINT OF ROOF
STRUCTURALDRAWINGS
NOTES:
LEDGER. SEE
2 x 3 DRAIN
SUPPORTS
2'-0" MIN.
1'-0"
PLATE
DOME STRAINER
4"
MIN
.
2"
A
B
O
V
E
LO
W
P
O
I
N
T
CLAMP
ASSEMBLY
UNDERDECK
COPPER. SEE
NOTE NO. 2.
4 LB. SHEET
OR 16 OZ. SOFT
TOP OF SHEATHING AT
LOW POINT ADJACENT
1'-6"
CAST IRON DOME STRAINER,ROOF DRAIN WITH GALV.
MIN. 6" ROUND OVERFLOW
DAM COLLAR
ROOFING
2" WATER
1.
2.
3.
LINE OF
BRACING,
SEE STRUCT.
LOW POINT
OF ROOF
DRAIN WELL.
ROOF FRAMING
MORE INFO.
SEE STRUCTURAL FOR
ELASTOMERIC PAINT FINISH
CONC. WALL
ROOFING CAP SHEET o/
SURFACE MOUNTED REGLET
SEALANT
SHEATHING PAPER
BASE SHEET
BUILT UP ROOF
SURFACE COATING (SEE ROOF PLAN)
12
"
M
I
N
.
LAP TPO ROOF FLASHINGO/SHT. MTL. FLANGES
ULTRA PLY TPO MEMBRANE
24
"
2"11"
2"
1'-
4
"
1'
-
6
"
1"6"
4"
18" X 18" 24 GA GALV MTL
GALV MTL DOWNSPOUT.SOLDER ALL SEAMS AND JOINT
12
"
M
I
N
.
24
"
8"
ROOF DRAIN & COLLECTOR BOX
SCALE: N.T.S.
COLLECTOR BOX w/ 6x6
XX
X
X
X
X
CARLISLE UNIVERSAL SINGLE-PLY SEALANT
SURE-WHITE PRESSURE-SENSITIVE
ELASTOFORM FLASHING IN
CONJUNCTION w/ TPO PRIMER
SURE-WELD BONDING ADHESIVE
WATER CUT-OFF MASTIC
XXXXXX
WATER CUT-OFF MASTIC
3
SEALANT AT
PERIMETER 4
1
2
NOTES:
WOOD NAILERS ARE INSTALLED ONLY AT SCUPPERS TO
SECURE METAL SLEEVE AND MUST EXTEND PAST THE
WIDTH OF METAL SLEEVE FLANGE.
UNIVERSAL SINGLE-PLY SEALANT IS REQUIRED AT
FLASHING EDGES ON SCUPPER EDGE. TPO PRIMER MUST
BE USED TO PREPARE SURFACES PRIOR TO THE
APPLICATION OF SEALANT.
PARAPET WALL
TPO MEMBRANE
TPO MEMBRANE
SURE-WHITE PRESSURE-SENSITIVE ELASTOFORM
FLASHING IN CONJUNCTION w/ TPO PRIMER
METAL SCUPPER
WOOD NAILER (BY GC)
SCUPPER FLANGES MUST BE TOTALLY COVERED BY
PRESSURE-SENSITIVE ELASTOFORM
FLASHING WITH MINIMUM 2" COVERAGE PAST NAIL HEAD.
4.
3.
2.
1.
ALL AROUND
CONC. SLEEVE W/ SEALANT
12" x 24" CONC. SPLASH
BLOCK
FIN. GRADE
DRAIN PIPE
OVERFLOW DRAIN
(ADJACENT TO ROOF DRAIN)
ROOF DRAIN LEADER
SCALE: N.T.S.
PRE-BASE AND REINFORCING MESH
o/ TOP AND EXPOSED FACES OF CORNICE
26 GA. GALVANIZED MTL STRAP
@ 24" O.C.- SCREWED TO HAT
CHANNEL @ CORNICE AND
TOP OF PARAPET
CONTINUOUS 16 GA.
HAT CHANNEL
APPROVED SEALANT
SLOPE24 GA. PAINTED
MTL. CAP FLASHING
MASONRY WALL
SHAPED FOAM CORNICE
w/ ADHESIVE TO BROWN COAT
4"
4"
EXPOSED C.M.U
w/ ELASTOMERIC PAINT
OR F.F. METAL SIDING
WHERE OCCURS
(SEE EXT. ELEVATIONS)
CORNICE @ PARAPET WALL
COVER
HINGE
CURB WITH
INTEGRAL CAP
FLASHING & BILCLIP
3-1/2"
2-1/4"
COVER LINER
AUTOMATIC
HOUSING
OPPOSITE END
7
3
/
8
"
HOLD OPEN ARM
SANTOPRENE GASKET
1" FIBERGLASS INSULATION
ALL AROUND COVER
LIFTING MECHANISM
SHOCK ABSORBER
3'-0"
2-1/4"
3-1/2"
1" RIGID FIBERBOARD
INSULATION ALL
AROUND OUTSIDE OF
CURB
CUT AROUNDCORRUGATIONS
CORRUGATED
1 LAYER 5/8"
26 GA. MIN. FLASHING
"BITUTHANE" SELF-
ADHERING & -SEALING
WATERPROOFING
1'-
0
"
CURB SHALL BE OF 14 GA. PAINT BOND G-90 GALVANIZED STEEL, 12" IN HEIGHT ON HINGE SIDES.
CURB SHALL BE FORMED WITH A 3-1/2" FLANGE WITH HOLES FOR SECURING TO THE ROOF DECK
AND WITH AN INTEGRAL METAL CAPFLASHING OF THE SAME GAUGE AND MATERIAL AS THE
CURB, FULL WELDED FOR WEATHERTIGHTNESS. CAPFLASHING SHALL BE EQUIPPED WITH THE
BILCLIP (TM) FLASHING SYSTEM, INCLUDING STAMPED TABS AND PAK-ROPE. INSULATION ON THE
EXTERIOR OF THE CURB SHALL BE RIGID FIBERBOARD 1" IN THICKNESS. ALL HARDWARE SHALL BE
ZINC PLATED AND CHROMATE SEALED. FACTORY FINISH SHALL BE (RED OXIDE PRIMER ON STEEL.
SPECIFICATIONS: FURNISH AND INSTALL WHERE INDICATED ON THE PLANS, ROOF ACCESS
HATCH, SIZE 3x3.5 AS MANUFACTURED BY THE BILCO COMPANY. INSTALLATION SHALL BE IN
ACCORDANCE WITH MANUFACTURES'S INSTRUCTIONS. MANUFACTURER SHALL GUARANTEE
AGAINST DEFECTS IN MATERIAL OR WORKMANSHIP FOR A PERIOD OF FIVE YEARS.
CONTRACTOR SHALL TEST FOR PROPER OPERATION AFTER INSTALLATION.
STUD WALL-TYP,
TYPE 'X' GYP.BD.
EACH SIDE OF
METAL ROOFING
AROUND EDGE OF
(DOW OR EQUAL)
SILICONE SEALANT
FLASHING TO ROOF
CORRUGATIONS &
INSIDE FLASHING
WARPPED AROUND
MECHANISM
COUNTERFLASHING
& NUTS
"STRATAVENT" BASE SHEET
ROOF HATCH TO SIT
LEVEL ON ROOF
1" FIBER INSULATION
NEOPRENE GASKET ALLAROUND CURB TOP
NON-REMOVABLE PINS
LIFTING
ROOF HATCH AND ACCESS LADDER
SCALE: N.T.S.
EXTERIOR DOOR HEAD
SCALE: N.T.S.
EXTERIOR DOOR JAMB
SCALE: N.T.S.
NOT USED
SCALE: N.T.S.
STOREFRONT DOOR HEAD
SCALE: N.T.S.
STOREFRONT WINDOW SILL
SCALE: N.T.S.
1/2" MAX.
DOOR CONDITION EXCEPT @ ENTRY
CONC. SLAB
C.M.U. WALL
CMU WALL
1/8" MIN. PER FT.
1/4" MIN. PER FT.
EXP. JT. FILLER
EXT. JOINT w/ SEALANT
AND BACKER ROD
STUCCO FINISH
DOOR OPENING
SEE SCHEDULE
H.M. DOOR
@ EXTERIOR BUILDING
& BACKER ROD
SEALANT
CONC. BLOCK
WHERE OCCURS
CLOSER
SEALANT
(SOLID GROUT)
TIMELY PREFINISHED
KNOCK DOWN (KD) FRAME
7'-0"
STOREFRONT DOOR
SEE MANUFACTURER
WEATHER STRIPPING
FOR MORE INFO.
SEE MANUFACTURER
STOREFRONT WINDOW
FOR MORE INFO.
5/8" GYP. BD. FIN.
FILLER @ REQ'D
CAULK & MOLDING
CONC. BLOCK WALL
ALUM. STOREFRONT, PRE-FINISHED
DOOR SCHEDULE
STOREFRONT DOOR SEE
VISION GLASS
SEE MANUFACUTRE
STOREFRONT DOOR
FOR MORE INFO.
F.F.1/
4
"
S
L
O
P
E
1:
2
1/
4
"
MA
X
.
WEATHER STRIPPING
EXPANSION JOINT FILLER
CONC. SLAB-SEE STRUCT.
THRESHOLD
ANODIZ. ALUM.
PER SCHEDULE
INT. FLOOR FIN.
VISION GLASS
ANODIZ. ALUM. STOREFRONT
SILL-SET IN MASTIC
INT. FLOOR FIN.
PER SCHEDULE
CONC. SLAB-SEE STRUCT.
EXPANSION JOINT FILLER
CAULKING W/ BACKER ROD-
DO NOT BLOCK WEEP HOLES
2% MAX.
SLOPE
1/
2
"
M
A
X
.
1/
2
"
M
A
X
.
C.M.U. WALL
MTL. DOOR
(SOLID GROUT)
SEE SCHEDULE
MTL. DOOR FRAME
SEALANT & BACKER ROD
SEE SCHEDULE
STOREFRONT DOOR JAMB
SCALE: N.T.S.
STOREFRONT DOOR THRESHOLD
SCALE: N.T.S.
2% MAX.
SLOPE
METAL SIDING
BASE TRIM W/ WEEP
HOLES @ 12" O.C. SET IN
SEALANT -PAINT TO
MATCH SIDING SECURE TO
EDGE METAL @ FLR DECK
EDGE TRIM @ VERTICALPBD PANEL O/ GRADE-D
BLDG. PAPER -PAINT TO
MATCH SIDING SECURE TO
EDGE METAL @ FLR DECK
CONCRETE BLOCK AT WALK
SCALE: N.T.S.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1516
1
ROOF
ACCESS
LADDER
7"
MIN.
SAFETY BAR ON EACH SIDE
OF LADDER TO EXTEND 42"
ABOVE THE ROOF EDGE
36"x30" ACCESS HATCH
BIL-CLIP TAB MEMBRANE
TERMINATION
FI
E
L
D
V
E
R
I
F
Y
E
X
A
C
T
H
E
I
G
H
T
NOTE:
RUNGS TO BE CAPABLE OF
WITHSTANDING A 300 LB LOAD
12"x3" EXPANSION BOLT
EACH LEG
42
"
ROOF RAILING
FIBERGLASS REINFORCED
POLYMER (FRP), YELLOW,
UV RESISTANT & FIRE
RETARDANT (Ø1.91)
42
"
A
B
O
V
E
T
H
E
RO
O
F
S
U
R
F
A
C
E
ALUMINUM POST HINGE
STAINLESS STEEL
TORSION ROD SELF CLOSING (FRP)
GATE (Ø1.91)
ALUMINUM GATE HINGE
STEEL CORNER BRACKETS
(HOT DIP GALV.)
ALUMINUM POST
SUPPORTS
BILCO BIL-GUARD
TYPE S E F HATCH RAIL
SYSTEM SINGLE LEAF
ROOF SCUTTLE
4"
MA
X
.
4'-
0
"
±
O
.
C
.
B
E
T
W
E
E
N
EA
C
H
S
U
P
P
O
R
T
12
"
TY
P
.
6"
MI
N
.
2
2/28/2024 6:40:32 PM
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
DATE NO. DESCRIPTION
DRAWN BY:
DRAWING TITLE
SCALE:
SHEET NO.
REVISION
ACRC
AS SHOWN
unless they are sealed, signed and dated
not final and ready for use, and therefore not valid
As instruments of service, these documents are
of acceptance of these restrictions.
or specifications shall constitute conclusive evidence
of the Architect. Visual contact with these drawings
have been prepared, without the written consent
other than the specific project for which they
shall be reproduced or used for any purpose
property of the Architect and no part thereof
and arrangements represented thereby are the
These drawings, specifications, ideas, designs
5120 HAMNER AVE
# 140
EASTVALE, CA 91752
951.454.8801
PROJECT
DATE: FEB. 08, 2023
PLAN CHECK NO.
A
R
C
ESIGN
www.acrcdesigns.com
P.C. CORRECTION12/27/23
P.C. CORRECTION28/25/23
P.C. CORRECTION32/25/24
ARCHITECTURAL
DETAILS
A7.2
4'-0" MAX.
5/8" W.R. GYP. BD.
GRID SYSTEM BASED ON ARMSTRONG
DRYWALL GRID SYSTEM. (SEE
WWW.ARMSTRONG.COM\SEISMIC FOR
ADDITIONAL INFO & TEST SUMMARIES)
12 GA. WIRE WITH
THREE TIGHT TURNS IN
1-1/2" AT BOTH ENDS
(48" O.C. MAX
SPACING)4" MIN
MAIN BEAM @ 48" O.C.
5/8" GYP. BD. CEILING w/
#6.5 (1 1/4")SCREWS @ 7" O/C
MAX AT ALL SUPPORTS,
INCLUDING PERIMETER
BLOCKING & NOT MORE
THAN 3/8" FROM EDGES &
ENDS OF GYP. BD.
SPLAY WIRE
45° MAX.
CROSS TEE @ 24" O.C.
24 GA. GALV. STEEL
STUD COMPRESSION
POST. SPACE NO MORE
THAN 12' x 12' AREA,
SAME AS SPLAY WIRE.-
SCREW TO STRUCTURE &
MAIN RUNNER PER
MANUF'S INSTALLATION
INSTRUCTIONS
KAM 12 WALL
MOULDING
ACOUSTICAL
CEILING PANEL
No. 12 GA MIN.
PLAN
ELEVATION
90° 90°
NOTE:
1. TIE TWO ADJACENT WALLS TO CEILING MAIN AND CROSS RUNNERS
2. SPRINKLER HEADS OR OTHER PENETRATIONS SHALL HAVE A 2" OVERSIZE RING,
SLEEVE, OR ADAPTER THROUGH CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT
LEAST 1" IN ALL HORIZONTAL DIRECTIONS.
FI
N
I
S
H
C
E
I
L
I
N
G
H
E
I
G
H
T
4'-0"
MAX.
8"
12'-0" O.C.
3/8"
3/8"
MIN.
CLR.
8"
4
5
°
CR
O
S
S
R
U
N
N
E
R
OR
M
A
I
N
R
U
N
N
E
R
8"
12
'
-
0
"
O
.
C
.
4'
-
0
"
MA
X
.
2
-
EA. WAY AND WITHIN 4'-0" OF
INDEPENDENT CADY SUPPORT
CLIP AT EA. AT EA. LIGHT
PERIMETER WALLS
CONNECTION
MAIN RUNNER
INTERSECTIONS.
CROSS TEE
EXTEND TO AND FASTEN TO
1/2"
E.M.T. DIA.
3/4"
MTL. ANGLE
L 3 x 3 x 3/16
L 2 x 2 x 1/8
8" MAX
TERMINATION
END OF ALL
RUNNERS
1"
3'-9"
6'-6"
5'-2"
GREATER THAN 6'-6" MAX.
MAX. LENGTH
MAX. LENGTH
LESS THAN 6'-6"
STRUT SHALL BE ADEQUATE TO
INSTALL BRACING AT 12'-0" O.C.
(4) 12 GA. SPLAY WIRES IN PLANE
RESIST THE VERTICAL COMPONENT
INDUCED BY THE BRACING WIRES.
OF EA. RUNNER, VERTICAL ANGLE
WIRES APPROXIMATELY 2" FROM
45 DEGREES MAX. SECURE ALL
12. GA. WIRE THREADED THROUGH.
STRUCTURAL MEMBERS ABOVE.
FASTEN TO THE MAIN RUNNER AND
SQUARE TUBING OR PIPE STRUT
STRUT PER A.S.T.M. C635 AND C636
HEAVY DUTY PER CBC 2010
CROSS TEES @24" O.C. - TYP.
NOTE:
AND TILE LAYOUT AND IN BOTH DIRECTIONS AT 12'-0" THEREAFTER.
MAIN TEE @ 48" O.C. TYP.
TAPPING SCREWS AT EA. STUD
CONTINUOUS ANGLE W/ SELF
FINISHED FACE OF WALL OR SOFFIT
LAY-IN ACCOUSTICAL
CEILING PANEL
4'-0" TYP.
TO EACH OTHER (4 WIRES) BEGINNING 4'-0" FROM STARTING POINT OF GRID
INSTALL CEILING GRID USING NO. 12 GA SPLAY WIRE HANGERS @ 45/90
8" MAX
3/4" TYP.
GYPSUM BOARD CEILING
SCALE: N. T. S.
CEILING CONNECTION AT WALL
SCALE: N. T. S.
CEILING SUSPENSION SYSTEM
SCALE: N. T. S.
CEILING STRUCT BRACING
SCALE: N. T. S.
RESTRAIN CEILING SYSTEM AT TWO
ADJACENT WALLS, LEAVING
REMAINING WALLS UNRESTRAINED
RESTRAINED JOINTA UNRESTRAINED JOINTB
"DONN" TELESCOPIC
COMPRESSION STRUT
12 GA. WIRE WITH THREE TIGHT
TURNS IN 1 1/2" AT BOTH ENDS
SPLICES WILL BE THRU
CONNECTION
POP RIVET TO CEILING RUNNERS,
FINISH TO MATCH CEILING SYSTEM
HANGER WIRE @ 48" O.C. MAX.
SPLAY WIRE
8" MAX. OR 1/4 OF THE LENGTH OF
THE END
LEDGER ANGLE WITH #8
SELF-TAPPING S.M.S. AT EACH STUD
(TYP.)
2"
MAX.MAX.
2"
4'-0" MAX.
45° MAX.
8" MAX.
STRUT OR 16 GA. WIRE
CONCEALED METAL
POP RIVET TO CEILING
ACOUSTICAL PANELS
RUNNERS
(TYP.)
WALL (TYP.)
INTERLOCK
WALL AT 12" O.C.
WIRES PARALLEL TO
ONE PAIR OF BRACING
MAIN RUNNER (TYP.)
SPLAY WIRE
12 MIN. GA. HANGER WIRE @ 48" O.C.
MAX. FOR MAIN RUNNERS & @ 24" O.C.
FOR CROSS MEMBERS
(ALTERNATE METHOD IF "A" IS NOT POSSIBLE)
SUSPENDED LAY-IN PANEL CEILING
SCALE: N. T. S.
PER FINISH SCHEDULE
GYP. BD. IN RESTROOM)
(USE WATER RESISTANCE
FOR NEW FINISH
PREPARE AS REQUIRED
TAPE AND SAND JOINTS
BASE TRACK
(E) CONC. SLAB
5/8" GYP. BD. - TYP
DETAIL "A"
DETAIL "B"
TILE OVER 5/8" GYP. BD.
TAPE ON 3/4" BULLNOSE
MTL. STUD
INT. FIN. OVER 5/8" GYP. BD.
MTL. STUD
CORNER BEAD (BEADEX)
2"
CONTINUOUS BEAD OF CAULKING,
TYP AT ALL EDGES OF GYP.BD.
DOOR, SEE SCHEDULE
H.M. FRAME, TYPICAL
SHIM AS REQUIRED
METAL STUD HEADER
GYP.BD. @ EA. SIDE,
TYPICAL.
SE
E
S
C
H
E
D
VARIES
DOOR FRAME ANCHORS,
TYPICAL, (3) PER JAMB.
2" TYP.
CONTINUOUS BEAD OF CAULKING,
TYPICAL AT ALL EDGES OF GYP.BD.
DOUBLE METAL STUDS
DOOR, SEE SCHEDULE
GYP.BD. @ EA. SIDE,
TYPICAL.
HM FRAME TYPICAL
1/2" DRYWALL APPLIED HORIZONTALLY
1" TYPE S DRYWALL SCREWS
@ 8" O.C. TYP
OR VERTICALLY W/ VERTICAL JOINT OVER STUDS.
(N) #8 SCREW
@ 32 " O.C. TYP.
STUD TO STUD
GYP. BD. IN RESTROOM)
(USE WATER RESISTANCE
FOR NEW FINISH
PREPARE AS REQUIRED
TAPE AND SAND JOINTS
5/8" GYP. BD. - TYP
TAPE ON 3/4" BULLNOSE
CORNER BEAD (BEADEX)
INT. FIN. OVER 5/8" GYP. BD.
INT. FIN. OVER 5/8" GYP. BD.
FASTENER @ 24" O.C.
(ICC-ES ESR-2269)
HILTI X-U 37 P8
SOUND INSULATION -PER OWNER
ONE LAYER 5/8" GYP. BD.
EACH SIDE
SEE STRUCTURAL
CEILING WHERE OCCURS
METAL STUD MODEL #305S125-30
1 1/4"x3 1/2"x20 GA. METAL STUDS @ 16" O.C.
TRACK PER ICC-ES ESR-3064P
ROOF FRAMING
CONTINUOUS METAL TRACK
INTERIOR DOOR HEAD
SCALE: N. T. S.
INTERIOR DOOR JAMB
SCALE: N. T. S.
WALL TO FLOOR CONNECTION
SCALE: N. T. S.
NON-COMBUSTIBLE WAL DETAIL
SCALE: N. T. S.
METAL STUD WALL INTERSECTION
SCALE: N. T. S.
METAL STUD WALL CORNER DETAIL
SCALE: N. T. S.
METAL STUD MODEL #305S125-30
1 1/4"x3 1/2"x20 GA. METAL STUDS @ 16" O.C.
TRACK PER ICC-ES ESR-3064P
METAL STUD MODEL #305S125-30
1 1/4"x3 1/2"x20 GA. METAL STUDS @ 16" O.C.
TRACK PER ICC-ES ESR-3064P
METAL STUD MODEL #305S125-30
1 1/4"x3 1/2"x20 GA. METAL STUDS @ 16" O.C.
TRACK PER ICC-ES ESR-3064P
SE
E
S
T
R
U
C
T
U
R
A
L
D
W
G
S
HILTI X-U 37 P8 FASTENER @ 24" O.C.
(ICC-ES ESR-2269)
MIN.
3/4"
MIN.
3/4"
MIN.
2"
11
10
9
8
7
6
1
4
5 3
2
1
METAL STUD WALL DETAIL
SCALE: N. T. S.
12
CONCRETE BLOCKS * - NOMINAL 6 BY 8 IN. HOLLOW OR SOLID. CLASSIFICATION D-2 (2 HR.)
ANCHOR CONCRETE PRODUCTS INC.
1.
FIRE RATING OF CONCRTE MASONRY WALLS EXPANDED CLAY, SHALE OR SLATE AGGREGATES
WIDTH (W)
1
HORIZONTAL SECTION
2
WI
D
T
H
NOMINAL SPECIFIED PARTIAL GROUTED OR HOLLOW MASONRY
HORIZONTAL SECTION
PARTIAL GROUTED OR HOLLOW MASONRY
1
WI
D
T
H
2
4"3 5/8"LESS THAN 1 HOUR 2 HOURS
1 HOUR6"5 5/8"4 HOURS
2 HOUR7 5/8"8"4 HOURS
2.
NOTES:
FIRE RATED MASONRY CONTROL JOINTS
SCALE: N. T. S.
14
FOR RATINGS UP TO AND INCLUDING 2 HOURS
JOINT WIDTH
1/2" MAXIMUM CONTROL
GASKET
JOINT BACKING
CAULK
ALLOWABLE COMPRESSIVE STRESS OF 57% OF MAX. ALLOWABLE COMPRESSIVE STRESS IN ACCORDANCE WITH THE
EMPIRICAL DESIGN METHOD.
ALLOWABLE COMPRESSIVE STRESS OF 75.6% OF MAX. ALLOWABLE COMPRESSIVE STRESS IN ACCORDANCE WITH THE
EMPIRICAL DESIGN METHOD.
MORTAR - BLOCKS LAID IN FULL BED OF MORTAR, NOM. 3/8" IN. THICK, OF NOT LESS THAN 2-1/4" AND NOT MORE THAN
3-1/2 PARTS OF CLEAN SHARP SAND TO 1 PART PORTLAND CEMENT (PROPORTIONED BY VOLUME) AND NOT MORE THAN
50 PERCENT HYDRATED LIME (BY CEMENT VOLUME). VERTICAL JOINTS STAGGERED.
1. THE FIRE RESISTIVE RATINGS OF THE VARIOUS THICKNESSES OF CONCRETE MASONRY WALLS (REINFORCED OR SOLID
GROUTED) HAVE BEEN CALCULATED BASED ON CALIFORNIA BUILDING CODE TABLE NO. 720.1(2), ITEMS 3-1.1 THROUGH
3-1.4 BY THE EQUIVALENT THICKNESS METHOD USING THE MINIMUM THICKNESS OF THE FACE SHELLS & WEBS SPECIFIED IN
CBC STANDARD NO. 21-4
2. DETERMINING THE FIRE RESISTANCE RATINGS OF CONCRETE MASONRY WALLS USING BLENDED AGGREGATES, REFER
TO FOOTNOTE 17 TO TABLE 720.1(2) OF THE CBC
FIRE RATED CMU WALL DETAIL
SCALE: N. T. S.
13
2
2/28/2024 6:41:25 PM
TITLE 24 ENERGY STANDARD NOTES
-
·
·
DRAWING TITLE
TRICOLOR
ENGINEERING
SHEET NUMBER
M-
ARCHITECT
SITE ADDRESS:
PROJECT NAME:
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
AH
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S C
E
M
A
S
M 38319
LACIN
Henry Chen
Principal
ACRC Design Group
4403 Riverside Drive, Suite 'A'
Chino, CA 91710
951-454-8801
www.acrcdesigns.com
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
ACRC Design Group
1.0
DRAWING TITLE
TRICOLOR
ENGINEERING
SHEET NUMBER
M-
ARCHITECT
SITE ADDRESS:
PROJECT NAME:
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
AH
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S C
E
M
A
S
M 38319
LACIN
Henry Chen
Principal
ACRC Design Group
4403 Riverside Drive, Suite 'A'
Chino, CA 91710
951-454-8801
www.acrcdesigns.com
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
ACRC Design Group
1.1
DRAWING TITLE
TRICOLOR
ENGINEERING
SHEET NUMBER
M-
ARCHITECT
SITE ADDRESS:
PROJECT NAME:
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
AH
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S C
E
M
A
S
M 38319
LACIN
Henry Chen
Principal
ACRC Design Group
4403 Riverside Drive, Suite 'A'
Chino, CA 91710
951-454-8801
www.acrcdesigns.com
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
ACRC Design Group
1.2
SL
O
P
E
1/
4
"
:
1
2
EX
I
T
EX
I
T
EX
I
T
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,152
1 / 500 3
OFFICE
B 100
1 / 150 2
WAREHOUSE
S2 1,127
1 / 500 3
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,106
1 / 500 3
DRAWING TITLE
TRICOLOR
ENGINEERING
SHEET NUMBER
M-
ARCHITECT
SITE ADDRESS:
PROJECT NAME:
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
AH
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S C
E
M
A
S
M 38319
LACIN
Henry Chen
Principal
ACRC Design Group
4403 Riverside Drive, Suite 'A'
Chino, CA 91710
951-454-8801
www.acrcdesigns.com
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
ACRC Design Group
2.0
SL
O
P
E
1/
4
"
:
1
2
SL
O
P
E
1/
4
"
:
1
2
SL
O
P
E
1/
4
"
:
1
2
DRAWING TITLE
TRICOLOR
ENGINEERING
SHEET NUMBER
M-
ARCHITECT
SITE ADDRESS:
PROJECT NAME:
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
AH
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S C
E
M
A
S
M 38319
LACIN
Henry Chen
Principal
ACRC Design Group
4403 Riverside Drive, Suite 'A'
Chino, CA 91710
951-454-8801
www.acrcdesigns.com
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
ACRC Design Group
2.1
DRAWING TITLE
TRICOLOR
ENGINEERING
SHEET NUMBER
M-
ARCHITECT
SITE ADDRESS:
PROJECT NAME:
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
AH
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S C
E
M
A
S
M 38319
LACIN
Henry Chen
Principal
ACRC Design Group
4403 Riverside Drive, Suite 'A'
Chino, CA 91710
951-454-8801
www.acrcdesigns.com
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
ACRC Design Group
3.1
DRAWING TITLE
TRICOLOR
ENGINEERING
SHEET NUMBER
M-
ARCHITECT
SITE ADDRESS:
PROJECT NAME:
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
AH
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S C
E
M
A
S
M 38319
LACIN
Henry Chen
Principal
ACRC Design Group
4403 Riverside Drive, Suite 'A'
Chino, CA 91710
951-454-8801
www.acrcdesigns.com
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
ACRC Design Group
3.2
DRAWING TITLE
TRICOLOR
ENGINEERING, INC.
SHEET NUMBER
P-
ARCHITECT
SITE ADDRESS:
PROJECT NAME:
REEN
I
G
N
E
L
ANOIS
I
C
H
E
N
AINROFIL
AH
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S C
E
M
A
S
M 38319
LACIN
LA PORTE
WAREHOUSE
142 LA PORTE STREET
ARCADIA, CA. 91006
ACRC Design Group
Henry Chen
Principal
ACRC Design Group
4403 Riverside Drive, Suite 'A'
Chino, CA 91710
951-454-8801
www.acrcdesigns.com
0.1
DRAWING TITLE
TRICOLOR
ENGINEERING, INC.
SHEET NUMBER
P-
ARCHITECT
SITE ADDRESS:
PROJECT NAME:
REEN
I
G
N
E
L
ANOIS
I
C
H
E
N
AINROFIL
AH
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S C
E
M
A
S
M 38319
LACIN
LA PORTE
WAREHOUSE
142 LA PORTE STREET
ARCADIA, CA. 91006
ACRC Design Group
Henry Chen
Principal
ACRC Design Group
4403 Riverside Drive, Suite 'A'
Chino, CA 91710
951-454-8801
www.acrcdesigns.com
0.2
癋
01
WH
01
EX
癋
DRAWING TITLE
TRICOLOR
ENGINEERING, INC.
SHEET NUMBER
P-
ARCHITECT
SITE ADDRESS:
PROJECT NAME:
REEN
I
G
N
E
L
ANOIS
I
C
H
E
N
AINROFIL
AH
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S C
E
M
A
S
M 38319
LACIN
LA PORTE
WAREHOUSE
142 LA PORTE STREET
ARCADIA, CA. 91006
ACRC Design Group
Henry Chen
Principal
ACRC Design Group
4403 Riverside Drive, Suite 'A'
Chino, CA 91710
951-454-8801
www.acrcdesigns.com
0.3
VENT PIPE THROUGH ROOF DETAIL
TRAP PRIMER DETAILPIPE HANGING DETAIL CONDENSATE TO TAILPIECE DETAIL
PIPING SUPPORT DETAIL
1'
-
6
"
PARAPET
1'-0"
ROOF DRAIN
1
1
6'-0" X 3'-0" WELL (VERIFY)
MIN. 6" ROUND ROOF DRAIN
WITH GALVANIZED CAST IRON
PROVIDE GALV. MTL.
SUMP RECEIVER
SEE PLUMBING SPECIFICATIONS FOR ADDITIONAL INFORMATION.
ROOFING CONTRACTOR TO INSTALL 4 LB LEAD SHEET OVER COMPLETED
ROOF MEMBRANE AND STRIPPED IN PRIOR TO FINIAL SURFACING.
2'-6"
SLOPE OF
ROOF BEYOND
OVERFLOW SYSTEM INLETS SHALL BE LOCATED 2" ABOVE LOW POINT OF ROOF
STRUCTURAL
DRAWINGS
NOTES:
LEDGER. SEE
2 x 3 DRAIN
SUPPORTS
2'-0" MIN.
1'-0"
PLATE
DOME STRAINER
4"
MI
N
.
2"
A
B
O
V
E
LO
W
P
O
I
N
T
CLAMP
ASSEMBLY
UNDERDECK
COPPER. SEE
NOTE NO. 2.
4 LB. SHEET
OR 16 OZ. SOFT
TOP OF SHEATHING AT
LOW POINT ADJACENT
1'-6"
CAST IRON DOME STRAINER,ROOF DRAIN WITH GALV.
MIN. 6" ROUND OVERFLOW
DAM COLLAR
ROOFING
2" WATER
1.
2.
3.
LINE OF
BRACING,
SEE STRUCT.
LOW POINT
OF ROOF
DRAIN WELL.
ROOF DRAIN & OVERFLOW
SL
O
P
E
1/
4
"
:
1
2
EX
I
T
EX
I
T
EX
I
T
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,152
1 / 500 3
OFFICE
B 100
1 / 150 2
WAREHOUSE
S2 1,127
1 / 500 3
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,106
1 / 500 3
AL
L
E
Y
DRAWING TITLE
TRICOLOR
ENGINEERING, INC.
SHEET NUMBER
P-
ARCHITECT
SITE ADDRESS:
PROJECT NAME:
REEN
I
G
N
E
L
ANOIS
I
C
H
E
N
AINROFIL
AH
EFORPDERETSIGER
YO N G H U
CFOE
T
A
T
S C
E
M
A
S
M 38319
LACIN
LA PORTE
WAREHOUSE
142 LA PORTE STREET
ARCADIA, CA. 91006
ACRC Design Group
Henry Chen
Principal
ACRC Design Group
4403 Riverside Drive, Suite 'A'
Chino, CA 91710
951-454-8801
www.acrcdesigns.com
1.0
PLUMBING SITE PLAN
SCALE: 3/16" = 1'
1
P-1.0 N
SL
O
P
E
1/
4
"
:
1
2
EX
I
T
EX
I
T
EX
I
T
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,152
1 / 500 3
OFFICE
B 100
1 / 150 2
WAREHOUSE
S2 1,127
1 / 500 3
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,106
1 / 500 3
DRAWING TITLE
TRICOLOR
ENGINEERING, INC.
SHEET NUMBER
P-
ARCHITECT
SITE ADDRESS:
PROJECT NAME:
REEN
I
G
N
E
L
ANOIS
I
C
H
E
N
AINROFIL
AH
EFORPDERETSIGER
YO N G H U
CFOE
T
A
T
S C
E
M
A
S
M 38319
LACIN
LA PORTE
WAREHOUSE
142 LA PORTE STREET
ARCADIA, CA. 91006
ACRC Design Group
Henry Chen
Principal
ACRC Design Group
4403 Riverside Drive, Suite 'A'
Chino, CA 91710
951-454-8801
www.acrcdesigns.com
1.1
PLUMBING PLAN (COLD AND HOT WATER)
SCALE: 1/4" = 1'
1
P-1.1 N
SL
O
P
E
1/
4
"
:
1
2
EX
I
T
EX
I
T
EX
I
T
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,152
1 / 500 3
OFFICE
B 100
1 / 150 2
WAREHOUSE
S2 1,127
1 / 500 3
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,106
1 / 500 3
DRAWING TITLE
TRICOLOR
ENGINEERING, INC.
SHEET NUMBER
P-
ARCHITECT
SITE ADDRESS:
PROJECT NAME:
REEN
I
G
N
E
L
ANOIS
I
C
H
E
N
AINROFIL
AH
EFORPDERETSIGER
YO N G H U
CFOE
T
A
T
S C
E
M
A
S
M 38319
LACIN
LA PORTE
WAREHOUSE
142 LA PORTE STREET
ARCADIA, CA. 91006
ACRC Design Group
Henry Chen
Principal
ACRC Design Group
4403 Riverside Drive, Suite 'A'
Chino, CA 91710
951-454-8801
www.acrcdesigns.com
1.2
PLUMBING PLAN (WASTE AND VENT)
SCALE: 1/4" = 1'
1
P-1.2 N
SL
O
P
E
1/
4
"
:
1
2
SL
O
P
E
1/
4
"
:
1
2
SL
O
P
E
1/
4
"
:
1
2
DRAWING TITLE
TRICOLOR
ENGINEERING, INC.
SHEET NUMBER
P-
ARCHITECT
SITE ADDRESS:
PROJECT NAME:
REEN
I
G
N
E
L
ANOIS
I
C
H
E
N
AINROFIL
AH
EFORPDERETSIGER
YO N G H U
CFOE
T
A
T
S C
E
M
A
S
M 38319
LACIN
LA PORTE
WAREHOUSE
142 LA PORTE STREET
ARCADIA, CA. 91006
ACRC Design Group
Henry Chen
Principal
ACRC Design Group
4403 Riverside Drive, Suite 'A'
Chino, CA 91710
951-454-8801
www.acrcdesigns.com
1.3
ROOF DRAIN PLAN
SCALE: 1/4" = 1'
1
P-1.3 N
A
AC
A/C
AIC
AFC
AFF
AFG
AF
ABV
AL
ARCH
AS
AT
ATS
AWG
B/G
BKBD
BEL
C
CATV
CCTV
CB
CLG
CLF
CLR
CO
COAX
CONC
CONN
AMPERES
ALTERNATING CURRENT
AIR CONDITIONING
AMPERES INTERRUPTING CAPACITY
AVAILABLE FAULT CURRENT
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AMP FRAME/AMP FUSE
ABV
ALUMINUM
ARCHITECT OR ARCHITECTURAL
AMP SWITCH
AMP TRIP
AUTOMATIC TRANSFER SWITCH
AMERICAN WIRE GAUGE
BELOW GRADE
BACKBOARD
BELOW
CONDUIT WITH WIRE
CABLE TELEVISION
CLOSED CIRCUIT TELEVISION
CIRCUIT BREAKER
CEILING
CURRENT LIMITING FUSE
CLEAR
CONDUIT ONLY WITH NYLON PULLCORD
COAXIAL CABLE
CONCRETE
CONNECT OR CONNECTION
CONTINUATIONCONT
CONTR
CPT
CU
CONTRACTOR
CONTROL POWER TRANSFORMER
COPPER
CURRENT TRANSFORMERCT
CW
D
COLD WATER
DEDICATED OUTLET
DIRECT CURRENTDC
DIA
DISC
DIST
DIAMETER
DISCONNECT
DISTRIBUTION
DAMP LOCATIONDL
DB
DWGS
DISTRIBUTION SWITCHBOARD
DRAWINGS
EACHEA
EB
EC
EDF
EG
EF
EI
ELECT
ELEV
EMER, EM
EMT
EXIST, EX
°F
FA
FF
FFE
FIN
FIXT
FLUOR
FT
FTG
FVNR
G
GA
GALV
GC
GD
GFI
GFR
GG
GND
H
HAZMAT
HR
DEGREES FAHRENHEIT
FIRE ALARM
90-MINUTE BATTERY CONNECTED TO UNIT
ELECTRICAL CONTRACTOR
ELECTRICAL DRINKING FOUNTAIN
CONNECTED TO EMERGENCY GENERATOR
EXHAUST FAN
CONNECTED TO EMERGENCY INVERTER
ELECTRICAL
ELEVATION/ELEVATOR
EMERGENCY
ELECTRO-METALLIC TUBING
EXISTING
EQUIP EQUIPMENT
HP
HOA
HT
HTR
HZ
IG
IMC
INCAND
J-BOX
KCM
KS
KVA
KWH
LBS
LF
LOC
LT
LTG
LV
MH
MANUF
MAX
MC
MCC
MCP
HOUSE POWER
HAND-OFF-AUTOMATIC
HEIGHT
HEATER
HERTZ
ISOLATED GROUND
INTERMEDIATE METAL CONDUIT
INCANDESCENT
JUNCTION BOX
KILO-CIRCUIT-MIL
KNEE SPACE
KILO-VOLTAMPERE
KILO-WATT-HOUR
POUND
LINEAL FEET
LOCATION
LIGHT
LIGHTING
LOW VOLTAGE
MOUNTING HEIGHT
MANUFACTURER
MAXIMUM
MECHANICAL CONTRACTOR
MOTOR CONTROL CENTER
MOTOR CIRCUIT CENTER
MECHANICALMECH
MIN
MLO
MSB
MINIMUM
MAIN LUGS ONLY
MAIN SWITCHBOARD
MOUNTEDMTD
MTG MOUNTING
NC
NEC
NIC
NORMALLY CLOSED
NATIONAL ELECTRICAL CODE
NOT IN CONTRACT
NIGHT LIGHTNL
NTS
NO
NOT TO SCALE
NORMALLY OPEN
ON CENTEROC
OFCI
OFOI
PB
PC
PCTC
PE
PH
PIV
PL
PNL
PWR
PP
Q
QTY
REC
RECEPT
REF
REQ
RM
SB
SD
SF
STRUCT
SW
SWBD
TEM
TEMP
TEL
TC
POWER
POWER POLE
OWNER FINISHED CONTRACTOR INSTALLED
OWNER FINISHED OWNER INSTALLED
PULL BOX
PHOTOCELL CONTROL
PHOTOCELL/TIMECLOCK CONTROL
PNEUMATIC-ELECTRIC
PH
POST INDICATOR VALVE
PILOT LIGHT
PANEL
PLBG PLUMBING
TYP
UGPS
UL
UNO
V
VA
VFD
W/
WH
WP
WT
XFMR
XL
XN
TYPICAL
UNDERGROUND PULL SECTION
UNDERWRITERS LABORATORIES
UNLESS NOTED OTHERWISE
VOLTS
VOLTAMPERE
VARIABLE FREQUENCY DRIVE
WITH
WATER HEATER
WEATHER PROOF
WEIGHT
TRANSFORMER
EXISTING TO BE RELOCATED
NEW LOCATION OF RELOCATED FIXTURE
FINISHED FLOOR, FURNITURE FEED
FINISH FLOOR ELEVATION
FINISH OR FINISHED
FIXTURE
FLUORESCENT
FEET OR FOOT
FOOTING
FULL VOLTAGE NON-REVERSING
GROUND BUS OR WIRE
GAUGE
GALVANIZED
GENERAL CONTRACTOR
GARBAGE DISPOSAL
GROUND FLOOR RELAY
GREEN GROUND
GROUND
HORIZONTAL
HAZARDOUS MATERIAL
HOUR
AFCI ARC FAULT CIRCUIT INTERRUPTER
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GROUND FAULT INTERRUPTER
KW KILO-WATT
MCB MAIN CIRCUIT BREAKER
N NEUTRAL
PVC POLYVINYL CHLORIDE
FIXTURES WITH QUARTZ RESTRIKE
QUANTITY
RECESSED
RECEPTACLE
REQUIREMENTS
RIGID GALVANIZED STEEL
REFRIGERATOR
STANDBY
ROOM
RGS
SMOKE DETECTOR
SQUARE FEET
STRUCTURAL
SWITCH
SWITCHBOARD
SWICHGEAR
TEMPORARY
TEMPERATURE
TELEPHONE
SPEC SPECIFICATION
SWGR
TIMECLOCK
XR EXISTING TO BE REMOVED
ABBREVIATIONS AND DESCRIPTIONS
SCOPE OF WORK
1.THIS ELECTRICAL DRAWINGS, WHICH CONSTITUTE AN INTEGRAL PART
OFTHISCONTRACT SERVES AS THE WORKING DRAWINGS AND INDICATES THE
GENERAL LAYOUT OF THE ELECTRICAL SYSTEM. FIELD VERIFICATION OF
LOCATIONS ON PLANS IS REQUIRED SINCE ACTUAL LOCATIONS, DISTANCES
AND MOUNTING HEIGHTS WILL BE GOVERNED BY FIELD CONDITIONS.
2.ALL WORK AND MATERIAL SHALL BE IN ACCORDANCE WITH CALIFORNIA CODES
AND GOVERNING AUTHORITIES. NOTHING IN THESE PLANS OR SPECIFICATIONS
SHALL BE DEEMED AS PERMISSION TO VIOLATE THESE CODES AND
AUTHORITIES.
3.AS A MINIMUM, CONSTRUCTION SHALL COMPLY WITH THE 2019 CEC (OR LATEST
ISSUE ADOPTED BY THE ENFORCING JURIDICAL).
4.CONDUITS AND CONSTRUCTION FOR UTILITY SERVICES SHOWN ON THESE
DRAWING ARE FOR PRELIMINARY REFERENCE ONLY. CONSTRUCTION SHALL BE
IN ACCORDANCE WITH FINAL PLANS OF THE SERVING UTILITY COMPANIES.
5.THE MAIN ELECTRICAL SERVICE GROUND BUS SHALL BE GROUNDED TO
CONCRETE ENCASED ELECTRODE (UFER) IN ACCORDANCE WITH SECTION
250-50 OF NEC, AND ALSO BONDED TO THE PIPING SYSTEMS PER SECTION
250-104 OF NEC.
6.ALL WIRE, UNLESS NOTED OTHERWISE, SHALL BE COPPER, UL, LISTED FOR 600
VOLTS, #12 AWG (FOR CIRCUITS OF 100 VOLTS AND ABOVE). INSULATION SHALL
BE DUAL RATED THHN/THWN UNLESS NOTED OTHERWISE. ALUMINUM
CONDUCTORS IF INDICATED SHALL BE OF COMPACTED STRAND
CONSTRUCTION AND TERMINATED WITH UL LISTED TERMINATING ADAPTERS.
7.ALL FUSES SHALL BE OF THE DUAL ELEMENT CURRENT LIMITING, REJECTION
TYPE, UNLESS NOTED OTHERWISE.
8.THE ELECTRICAL CONTRACTOR SHALL PROVIDE SUPPORT FOR ALL FIXTURES
AND ELECTRICAL EQUIPMENTS TO COMPLY WITH THE SEISMIC REQUIREMENTS
OF THE CALIFORNIA BUILDING CODE AND ALL LOCAL ORDINANCES. THE
ELECTRICAL CONTRACTOR SHALL VERIFY WHO IS PROVIDING SUPPORT WIRE
FOR ALL LIGHTING FIXTURES IN SUSPENED CEILINGS AS REQUIRED BY CODE,
AND INCLUDE SAME IF NOT COVERED BY ANOTHER TRADE.
9.UNDERGROUND OR UNDER SLAB CONDUITS SHALL BE PVC SCHEDULE 40
UNLESS NOTED OTHERWISE. ALL NON-METALLIC CONDUIT SHALL CONTAIN AN
APPROPRIATELY SIZED EQUIPMENT GROUNDING CONDUCTOR. CONDUIT
ABOVE GRADE WHERE NOT EXPOSED TO SEVERE PHYSICAL DAMAGE SHALL BE
EMT. ALL OTHER CONDUIT SHALL BE IMC OR GALVANIZED RIGID CONDUIT,
EXCEPT AS OTHERWISE INDICATED. CONCEALED CONDUIT MAY BE ARMORED
CABLE, FLEX, OR EMT.
10.ALL DEVICE PLATES SHALL BE PLASTIC OF THE STANDARD COLOR AS
SELECTED BY THE ARCHITECT.
11.ALL ROOF PENETRATIONS SHALL BE FLASHED AND SEALED PROPERLY.
12.THE ENTIRE WIRING SYSTEM SHALL BE TESTED FOR SHORT CIRCUITS,
GROUNDS, AND SUFFICIENT INSULATION RESISTANCE BETWEEN CONDUCTORS
AND TO GROUND.
13.ALL OVER CURRENT DEVICES SHALL BE AT LEAST 75 ¡ãC RATED.
14.ALL METAL CONDUITS AND FITTINGS SHALL BE LISTED FOR GROUNDING
CONTINUITY.
15.MULTIWIRE CIRCUITS SHALL NOT BE INSTALLED.
16.ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED, LABELED, AND INSTALLED
PER THE CEC, THE INSTALLATION STANDARDS/MANUFACTURER'S
RECOMMENDATIONS AND, IF REQUIRED, A RECOGNIZED ELECTRICAL TESTING
LABORATORY. (CEC 110.2)
17.PANEL HOMERUN DESIGNATIONS:
PL 1&3&5 =ONE THREE PHASE, 3-WIRE CIRCUIT, NO NEUTRAL TO A 3-POLE
CIRCUIT BREAKER IN PANEL "PL".
PL 2&4 =ONE SINGLE PHASE, 2-WIRE CIRCUIT, NO NEUTRAL TO A 2-POLE
CIRCUIT BREAKER IN PANEL "PL".
PL 1,3,5 =THREE SINGLE PHASE CIRCUITS WITH SEPARATE NEUTRAL FOR
EACH
CIRCUIT TO 1-POLE CIRCUIT BREAKER IN PANEL "PL".
18.CEC 110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED,
OR CERTIFIED BY NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED
BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION.
19.BEES 130.5(C) VOLTAGE DROP: THE MAXIMUM COMBINED VOLTAGE DROP ON BOTH
INSTALLED FEEDER CONDUCTORS AND BRACH CIRCUIT CONDUCTORS TO THE
FARTHEST CONNECTED LOAD OR OUTLET SHALL NOT EXCEED 5 PERCENT.
1.PENETRATE NO STRUCTURAL ELEMENTS INCLUDING SHEAR WALLS,
WITHOUT WRITTEN CONSENT OF ARCHITECT.
2.PROVIDE CONDUIT ONLY FROM MECHANICAL UNITS TO RESPECTIVE
CONTROL DEVICES (T-STAT., BY-PASS TIMER, ENERGY MANAGEMENT
SYSTEM, ETC). COORDINATE LOCATIONS AND REQUIREMENTS WITH
MECHANICAL CONTRACTOR/DRAWINGS, AND COMPLY.
3.REFER TO MECHANICAL DRAWINGS/CONTRACTOR FOR CONTROLS
AND OTHER WORK REQUIRED BUT NOT SHOWN HERE, AND COMPLY.
E.C. IS ALSO TO PROVIDE CONDUITS REQUIRED FOR LOW-VOLTAGE
CONTROL WIRING (BY OTHERS).
4.FUSES FOR MECHANICAL EQUIPMENT ARE TO BE CLASS "RK-1", "BUSS"
TYPE "LPN-RK" (208V), OR "LPS-RK" (480V,) "LOW-PEAK". EQUIPMENT
NAMEPLATE RATING SUPERCEDES DESIGN VALUES.
5.ALL MECHANICAL AND EQUIPMENT AND DISCONNECT SWITCHES TO BE
MARKED.
6.ALL FLEX CONDUIT SHALL CARRY A COPPER BONDING WIRE, SIZED
PER NEC TABLE 250-122.
7.ALL ROOF MOUNTED AND EXTERIOR EQUIPMENT SHALL BE RATED
WEATHERPROOF (NEMA 3R).
8.CONTRACTOR IS TO PROVIDE ADEQUATE SUPPORT FOR
ROOF-MOUNTED EQUIPMENT.
9.NO CONDUIT IS TO RUN ON ROOF FOR MORE THAN 4'-0", ALL OTHER
CONDUIT IS TO RUN BELOW ROOF AND STUB THRU NEAR EQUIPMENT.
VERIFY LOCATIONS OF ALL STUB-UPS WITH MECHANICAL
DRAWINGS/CONTRACTOR PRIOR TO ROUGH-IN, AND COMPLY. ALL
ELECTRICAL PENETRATIONS THRU ROOF SHALL BE FLASHED.
COORDINATION NOTEGENERAL ELECTRICAL NOTES
SINGLE LINE SYMBOLS AND DESCRIPTIONS
M
PANEL
A
(N)
N E
L
ATS
G
M
M
A
V
GFCI
DM IACB SPD
LSI
LSIG
AMP METER
AUTOMATIC TRANSFER
SWITCH
CIRCUIT BREAKER
CURRENT
TRANSFORMER
GENERATOR SIZE AS
NOTED
DRAW-OUT CIRCUIT
BREAKER
EXTERNALLY OPERATED
CIRCUIT BREAKER
FUSED SWITCH
GROUND FAULT CIRCUIT
INTERRUPTER
GROUNDING ELECTRODE
AND CONDUCTOR
DIGITAL METER INSULATED AIR CIRCUIT
BREAKER
CIRCUIT BREAKER WITH
ELECTRONIC SENSING,
TIMING AND TRIPPING
CONTROL WITH FIELD
INTERCHANGEABLE TRIP
UNITS. PROVIDE TRUE RMS
FUNCTIONS WITH DISCRETE
FIELD ADJUSTABLE SETTINGS
INDEPENDENT OF OTHER
ADJUSTMENTS.
L. LONG TIME TRIP
S. SHORT TIME
OVERCURRENT TRIP
I. INSTANTANEOUS TRIP
CIRCUIT BREAKER WITH
ELECTRONIC SENSING, TIMING
AND TRIPPING CONTROL WITH
FIELD INTERCHANGEABLE TRIP
UNITS. PROVIDE TRUE RMS
FUNCTIONS WITH DESCRETE
FIELD ADJUSTABLE SETTINGS
INDEPENDENT OF OTHER
ADJUSTMENTS.
L. LONG TIME TRIP
S. SHORT TIME OVERCURRENT
TRIP
I. INSTANTANEOUS TRIP
G. GROUND FAULT TRIP,
GROUND FAULT
SENSING INTEGRAL WITH
CIRCUIT BREAKER.
METER, IN-LINE
UTILITY, 200A
MAXIMUM
METER WITH C.T.s ST
PANEL BOARD
VOLT METER
MOTOR
TRANSFORMER
TIMER CLOCK
SHUNT TRIP
SURGE PROTECTION
DEVICE
CONTRACTORS FIELD VERIFY EXISTING CONDITIONS AND MAKE
ELECTRICAL PANELS, CONDUITS, AND LIGHTING FIXTURES, ETC,
ADAPTABLE TO EXISTING CONDITIONS.
NOTE TO CONTRACTORS:
CODE COMPLIANCE
CALIFORNIA ELECTRICAL CODE 2019
CALIFORNIA ENERGY CODE 2019
CALIFORNIA BUIDING CODE 2019
CALIFORNIA GREEN BUILDING CODE 2019
REGULATIONS OF ALL OTHER AUTHORITIES HAVING
JURISDICTION
NEW POWER AND LIGHTING SYSTEM FOR NEW
WAREHOUSE.
E-0.1
E-0.2
E-1.1
E-1.2
E-2.1
E-2.2
E-3.1
GENERAL NOTES, ELECTRICAL SYMBOL LIST & SHEET INDEX
ELECTRICAL SYMBOLS AND DESCRIPTIONS
WAREHOUSE POWER PLAN
WAREHOUSE EMERGENCY PHOTOMETRICS
WAREHOUSE LIGHTING PLAN
ROOF POWER PLAN
SINGLE LINE DIAGRAM & PHOTOCELL SINGLE LINE DIAGRAM
SHEET INDEX
E-4.1 INDOOR LIGHTING T24 REPORT
E-4.2 INDOOR LIGHTING T24 REPORT
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
TC
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S E
L
E
A
S
E 21991
LACIR
DRAWING TITLE
TRICOLOR
ENGINEERING, INC
SHEET NUMBER
E
SITE ADDRESS:
PROJECT NAME:
DESIGNER IN CHARGE
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
4403 RIVERSIDE DR.
SUITE 'A'
CHINO, CA 91710
951.454.8801
A
R
C
ESIGN
www.acrcdesigns.com
1
2
-0.1
E-2.4 LUMINARIES SCHEDULE & SPECIFICATION SHEETS
E-1.3 OUTDOOR POWER PLAN
E-2.3 OUTDOOR LIGHTING PLANE & OUTDOOR LIGHTING PHOTOMETRICS
E-3.2 ELECTRICAL SITE PLAN & PANEL SCHEDULE
E-4.3 OUTDOOR LIGHTING T24 REPORT
E-4.4 OUTDOOR LIGHTING T24 REPORT
E-4.5 LIGTING CONTROL EQUIPMENT SCHEDULE
1
OC
P
A
30
SD
LA
2'X4' LED LIGHT FIXTURE, SURFACE MOUNTED ON CEILING
2'X4' LED LIGHT FIXTURE, RECESSED IN CEILING.
2'X4' EMERGENCY LED LIGHT FIXTURE, RECESSED IN CEILING.
2'X4' EMERGENCY LED LIGHT FIXTURE, SURFACE MOUNTED ON CEILING
2'X2' LED LIGHT FIXTURE, SURFACE MOUNTED ON CEILING
2'X2' EMERGENCY LED LIGHT FIXTURE, SURFACE MOUNTED ON CEILING
2'X2' LED LIGHT FIXTURE, RECESSED IN CEILING.
2'X2' EMERGENCY LED LIGHT FIXTURE, RECESSED IN CEILING.
1'X4' LED LIGHT FIXTURE, SURFACE MOUNTED ON CEILING
1'X4' LED LIGHT FIXTURE, RECESSED IN CEILING.
1'X4' EMERGENCY LED LIGHT FIXTURE, RECESSED IN CEILING.
1'X4' EMERGENCY LED LIGHT FIXTURE, SURFACE MOUNTED ON CEILING
STRIP LIGHT FIXTURE, CEILING MOUNTED OR SUSPENDED
LIGHT FIXTURE, RECESSED IN CEILING.
LIGHT FIXTURE, PENDANT
LIGHT TRACK WITH LIGHTS, SURFACE MOUNTED OR SUSPENDED
LIGHT FIXTURE, WALL MOUNTED
STRIP EMERGENCY LIGHT FIXTURE, CEILING MOUNTED OR SUSPENDED
LIGHT FIXTURE, SURFACE MOUNTED ON CEILING.
EMERGENCY LIGHT FIXTURE, RECESSED IN CEILING.
EMERGENCY LIGHT FIXTURE, SURFACE MOUNTED ON CEILING.
INDICATES: A = FIXTURE TYPE; 30 = WATTAGE PER FIXTURE. ALSO NUMBER
ADJACENT TO FIXTURE = CIRCUIT NUMBER, AND LOWER CASE LETTER =
CONTROLLING SWITCH.
EXIT SIGN WITH EMERGENCY LIGHTS, WALL MOUNTED WITH MINIMUM 90
MINUTES BATTERY PACK
EXIT SIGN WITH EMERGENCY LIGHTS, PENDANT, WITH MINIMUM 90 MINUTES
BATTERY PACK
EMERGENCY LIGHT FIXTURE, WALL MOUNTED
DAYLIGHT ZONE
DAYLIGHT SENSOR, CEILING MOUNTED
PHOTOCELL SENSOR, CEILING MOUNTED
WALL MOUNTED DIMMER, +46"
WALL MOUNTED DIMMER WITH BUILT IN OCCUPANCY SENSOR, +46"
WALL MOUNTED TOGGLE SWITCH, +46"
SMOKE DETECTOR
DUPLEX RECEPTACLE, 120V, +12" AFF/AFG, UNLESS NOTED OTHERWISE
GFCI DUPLEX RECEPTACLE, 120V, +12" AFF/AFG, UNLESS NOTED OTHER WISE
SPLIT WIRED DUPLEX RECEPTACLE, ONE RECEPTACLE CONTROLLED BY
OCCUPANCY SENSOR, 120V, +12" AFF/AFG, UNLESS NOTED OTHERWISE
STAND QUAD, 120V, +12" AFF/AFG, UNLESS NOTED OTHERWISE
SPECIAL PURPOSE RECEPTACLE, SINGLE PHASE. CONFIGURATION AND AMPS
AS NOTE ON PLAN
SPECIAL PURPOSE RECEPTACLE, THREE PHASE. CONFIGURATION AND AMPS
AS NOTE ON PLAN
FLUSH FLOOR SERVICE BOX WITH TWO DUPLEX RECEPTACLES AND
COMBINATION VOICE/DATA OUTLET WITH NUMBER OF VOICE AND DATA JACKS
AS NOTED.
DUPLEX RECEPTACLE IN FLUSH FLOOR BOX WITH HINGED COVER
JUNCTION BOX, RECESSED IN CEILING.
JUNCTION BOX, SURFACE MOUNTED ON CEILING
DOUBLE DUPLEX RECEPTACLE IN FLUSH FLOOR BOX WITH HINGED COVER
JUNCTION BOX, SURFACE MOUNTED ON WALL
LA, ELECTRICAL PANEL NAME. PANEL DESIGNATION
PULL BOX, SEE SIZE ON DRAWING
FLUSH MOUNTED PANEL BOARD, +6'-6" TO TOP
SURFACE MOUNTED PANEL BOARD, +6'-6" TO TOP
SURFACE MOUNTED CABINET OR EQUIPMENT AS NOTED, +6'-6" TO TOP
FLUSH MOUNTED PANEL BOARD OR EQUIPMENT AS NOTED, +6'-6" TO TOP
FUSE DISCONNECT SWITCH
COMBINATION VOICE/DATA OUTLET WITH NUMBER OF VOICE AND DATA JACKS
AS NOTED, +18" OR AS NOTED.
TELEPHONE OUTLET, +18" OR AS NOTED.
TELEVISION OUTLET, +18" OR AS NOTED.
INSTANT HEAT FOR SINKS
CM
DUPLEX RECEPTACLE, 120V, CEILING MOUNTED
CARBON MONOXIDE DETECTOR
T
TELEVISION OUTLET
THERMOSTAT
3 WAY TOGGLE SWITCH
4 WAY TOGGLE SWITCH
3*
4*
GD GARBAGE DISPOSAL
SMART PANEL
S MOTOR STARTER
F
WALL MOUNTED SWITCH W/ OCCUPANCY SENSOR, +46"
EXIT SIGN WITH EMERGENCY LIGHTS, CEILING MOUNTED WITH MINIMUM 90
MINUTES BATTERY PACK
LIGHT FIXTURE, PENDANT, WITH MINIMUM 90 MINUTES BATTERY PACK
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
TC
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S E
L
E
A
S
E 21991
LACIR
DRAWING TITLE
TRICOLOR
ENGINEERING, INC
SHEET NUMBER
E
SITE ADDRESS:
PROJECT NAME:
DESIGNER IN CHARGE
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
4403 RIVERSIDE DR.
SUITE 'A'
CHINO, CA 91710
951.454.8801
A
R
C
ESIGN
www.acrcdesigns.com
1
2
-0.2
SL
O
P
E
1/
4
"
:
1
2
EX
I
T
EX
I
T
EX
I
T
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,152
1 / 500 3
OFFICE
B 100
1 / 150 2
WAREHOUSE
S2 1,127
1 / 500 3
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,106
1 / 500 3
2
PA
PB
PC
2 2
3
3
2
2
3
3
2
2
3
2
2
PA 2
PA 3
PB 2
PC 3
PC 2
33
PB 3
3
3 3
2 2
2
2
PA 8&10
PB 8&10
PC 8&10
WAREHOUSE POWER PLAN
SCALE: 1/8"=1'
1
E-1.1
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
TC
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S E
L
E
A
S
E 21991
LACIR
DRAWING TITLE
TRICOLOR
ENGINEERING, INC
SHEET NUMBER
E
SITE ADDRESS:
PROJECT NAME:
DESIGNER IN CHARGE
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
4403 RIVERSIDE DR.
SUITE 'A'
CHINO, CA 91710
951.454.8801
A
R
C
ESIGN
www.acrcdesigns.com
1
2
-1.1
2P,WP
PA 4&6
2P,WP
PB 4&6
2P,WP
PC 4&6
5
WP,WR
HP 5
5
WP,WR
F 30AS/15AF
F
F
30AS/15AF
30AS/15AF
FUTURE SOLAR PANEL AREA
ROOF POWER PLAN
SCALE: 1/4"=1'
1
E-1.2
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
TC
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S E
L
E
A
S
E 21991
LACIR
DRAWING TITLE
TRICOLOR
ENGINEERING, INC
SHEET NUMBER
E
SITE ADDRESS:
PROJECT NAME:
DESIGNER IN CHARGE
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
4403 RIVERSIDE DR.
SUITE 'A'
CHINO, CA 91710
951.454.8801
A
R
C
ESIGN
www.acrcdesigns.com
1
2
-1.2
1
SL
O
P
E
1/4
"
:
1
2
EX
I
T
EX
I
T
EX
I
T
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,152
1 / 500 3
OFFICE
B 100
1 / 150 2
WAREHOUSE
S2 1,127
1 / 500 3
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,106
1 / 500 3
AL
L
E
Y
EV CHARGER
HP 2&4, 1"C-2#8 & 1#10 GRD. THWN, CU.
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
TC
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S E
L
E
A
S
E 21991
LACIR
DRAWING TITLE
TRICOLOR
ENGINEERING, INC
SHEET NUMBER
E
SITE ADDRESS:
PROJECT NAME:
DESIGNER IN CHARGE
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
4403 RIVERSIDE DR.
SUITE 'A'
CHINO, CA 91710
951.454.8801
A
R
C
ESIGN
www.acrcdesigns.com
1
2
-1.3
OUTDOOR POWER PLAN
SCALE: 1/8"=1'
1
E-1.3
1
SL
O
P
E
1/
4
"
:
1
2
EX
I
T
EX
I
T
EX
I
T
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,152
1 / 500 3
OFFICE
B 100
1 / 150 2
WAREHOUSE
S2 1,127
1 / 500 3
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,106
1 / 500 3
4.4
4.3
5.2
4.7
4.9
4.8
4.2
4.1
3.8
3.7
2.6
2.5
3.1
3.2
2.8
3.1
2.7
3.0
2.4
2.5
4.1 4.2 4.1 3.7 3.6 4.1 4.2 4.7 4.2 3.1
3.7 3.8 3.2 3.7 3.7 4.2 4.7 5.2 4.8 4.2
4.6
5.2
5.2
5.4
4.7
4.7
4.1
4.4
3.7
3.7
3.1
3.1
4.7 4.8 4.2 3.6 3.1 2.6
3.5 3.5 3.4 3.4 1.7 1.7
2.8 3.2 3.8 4.5 4.7 4.7
3.2 3.7 4.1 4.7 5.1 5.1
3.2 3.7 4.1 4.7 5.1 4.7
4.3
3.9
4.3
4.2
4.7
4.3
4.8
3.8
4.1
3.4
3.7
3.0
3.5
3.1
3.2
2.8
3.1
2.7
3.0
2.4
2.5
4.1 4.2 4.1 3.7 3.6 3.7 4.2 4.7 4.2 3.1
3.7 3.8 3.2 3.7 3.7 3.2 3.6 4.2 3.6 2.8
WAREHOUSE EMERGENCY PHOTOMETRICS
SCALE: 1/4"=1'
1
E-2.1
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
TC
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S E
L
E
A
S
E 21991
LACIR
DRAWING TITLE
TRICOLOR
ENGINEERING, INC
SHEET NUMBER
E
SITE ADDRESS:
PROJECT NAME:
DESIGNER IN CHARGE
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
4403 RIVERSIDE DR.
SUITE 'A'
CHINO, CA 91710
951.454.8801
A
R
C
ESIGN
www.acrcdesigns.com
1
2
-2.1
SL
O
P
E
1/
4
"
:
1
2
EX
I
T
EX
I
T
EX
I
T
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,152
1 / 500 3
OFFICE
B 100
1 / 150 2
WAREHOUSE
S2 1,127
1 / 500 3
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,106
1 / 500 3
L1B
OC
OC
OC
PA 1
PB 1
PC 1
1CE
1C 1CE
1CE
1C 1CE
1C 1CE
1CE 1C
1A
1A
1A
1A
1A 1A
1B
1B
1B
P
P
P
PA 5
PB 5
PC 5
P
PRIMARY SKYLIT DAYLIT ZONE.
PRIMARY SKYLIT DAYLIT ZONE.
PRIMARY SKYLIT DAYLIT ZONE.
PRIMARY SKYLIT DAYLIT ZONE.
WAREHOUSE LIGHTING PLANE
SCALE: 1/8"=1'
1
E-2.2
2H
LTG TAG# / WATT
C,CE/85
B/9
A/23
QTY.
10
6
3
TYPE B UNIT LUMINAIRE SCHEDULE
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
TC
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S E
L
E
A
S
E 21991
LACIR
DRAWING TITLE
TRICOLOR
ENGINEERING, INC
SHEET NUMBER
E
SITE ADDRESS:
PROJECT NAME:
DESIGNER IN CHARGE
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
4403 RIVERSIDE DR.
SUITE 'A'
CHINO, CA 91710
951.454.8801
A
R
C
ESIGN
www.acrcdesigns.com
1
2
-2.2
1
1
1
1
HP 1
HP 3
1D
1D
1D 1D 1D
1D
1D
1D
3F
SL
O
P
E
1/
4
"
:
1
2
EX
I
T
EX
I
T
EX
I
T
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,152
1 / 500 3
OFFICE
B 100
1 / 150 2
WAREHOUSE
S2 1,127
1 / 500 3
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,106
1 / 500 3
SL
O
P
E
1/
4
"
:
1
2
EX
I
T
EX
I
T
EX
I
T
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,152
1 / 500 3
OFFICE
B 100
1 / 150 2
WAREHOUSE
S2 1,127
1 / 500 3
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,106
1 / 500 3
2.2
2.4
2.1
1.7
1.5
1.2
2.9
3.1
3.3
2.7
2.3
2.2
3.5
3.6
3.8
3.4
2.9
2.7
4.0
4.1
3.7
3.6
3.1
3.0
3.6
3.7
3.8
3.5
3.4
3.3
3.1
3.2
3.6
3.7
3.5
3.8
2.6
3.6
3.7
3.4
4.2
4.9
3.2
3.6
4.5
4.1
4.0
5.1
5.6
4.1
4.7
5.5
4.8
4.2
55
6.2
4.5
5.2
6.1
4.5
5.3
6.0
6.8
8.8
7.5
8.5 8.7 7.6 6.7 6.1 5.7 6.6 7.6 8.5 8.8 8.0 7.2 6.4 5.5 6.5 7.3 7.9 8.4 9.1
7.2
8.1
8.9
8.3
8.7
8.7
7.8
7.9
8.8
8.3
6.5
7.4
8.1
7.6
7.8
7.8
7.3
7.4
8.1
7.8
5.7
6.5
7.2
6.8
7.1
7.1
6.4
6.5
6.9
6.7
5.1
6.0
6.4
6.1
6.0
6.2
5.5
5.6
6.3
5.8
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
TC
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S E
L
E
A
S
E 21991
LACIR
DRAWING TITLE
TRICOLOR
ENGINEERING, INC
SHEET NUMBER
E
SITE ADDRESS:
PROJECT NAME:
DESIGNER IN CHARGE
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
4403 RIVERSIDE DR.
SUITE 'A'
CHINO, CA 91710
951.454.8801
A
R
C
ESIGN
www.acrcdesigns.com
1
2
-2.3
OUTDOOR LIGHTING PLAN
SCALE: 1/8"=1'
1
E-2.3 POLE LIGHT PEDESTAL DETAIL
SCALE: NONE
3
E-2.3
2H
LTG TAG# / WATT
D/20
QTY.
8
TYPE B UNIT LUMINAIRE SCHEDULE
OUTDOOR LIGHTING PHOTOMETRICS
SCALE: 1/8"=1'
2
E-2.3
F/66 1
Type C Metalux SSLED-LD5
LTG TAG# / WATT
C/85
DESCRIPTION MANUFACTURER, CATALOG#
WAREHOUSE PENDENT LTG
SERVING AREA REMARK
WAREHOUSE
LUMINARIES SCHEDULE
A/23
RESTROOM
METALUX, 22LCRL3040CRECESSED LTG
B/15 SURFACE MTD
OFFICE
SPECTRUM, SX1003RDLEDGV-15L-40KDS10X-GS-SM
M.H.
20'
8'
12'
METALUX, SSLED-LD5-12-W-UNV-L850-CD-SVPD3
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
TC
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S E
L
E
A
S
E 21991
LACIR
DRAWING TITLE
TRICOLOR
ENGINEERING, INC
SHEET NUMBER
E
SITE ADDRESS:
PROJECT NAME:
DESIGNER IN CHARGE
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
4403 RIVERSIDE DR.
SUITE 'A'
CHINO, CA 91710
951.454.8801
A
R
C
ESIGN
www.acrcdesigns.com
1
2
-2.4
CE/85 WAREHOUSE PENDENT LTG WAREHOUSE20'METALUX, SSLED-LD5-12-W-UNV-L850-EL20WREM-CD-SVPD3
Type B Metalux SSLED-LD5Type B Metalux SSLED-LD5
D/20 OUTDOOR WALL MTD LTG
Type D Rayon T631LED Type F McGraw Edison GLEON Type F McGraw Edison RSS Poles
NOTE:
1.ALL EMERGENCY LIGHTS SHALL BE EQUIPPED WITH MINIMUM 90 MINUTES BATTERY PACK.
2.THE OWNER AND CONTRACTOR DECIDE THE BRAND AND MODEL OF THE LIGHTING FIXTURES.
THE POWER CONSUMPTION OF ALL LIGHTING FIXTURES SHALL BE EQUAL TO OR LESS THAN
THE LUMINARIES SCHEDULE TO MATCH THE T24 REQUIREMENT.
SIDEWALK8'TECH-D, T631LED-20-UNI12-40-T3
QTY.
6
6
3
4
8
F/66 POLE LTG PARKING LOT15'MCGRAW-EDISON, GLEON-SA2A-750-U-T4FT 1
SINGLE LINE DIAGRAM
SCALE: NONE
1
E-3.1
100A
2P
40
0
A
PU
L
L
S
E
C
T
I
O
N
120Y/240V,2P,400A,42K AIC
"PA"
PANEL
"PB"
PANEL
100A
2P
100A
2P
1
1
/
2
"
C
-
3
#
1
&
1
#
8
G
N
D
.
T
H
W
N
,
C
U
.
±
4
0
'
V
.
D
=
-
0
.
1
5
%
1
1
/
2
"
C
-
3
#
1
&
1
#
8
G
N
D
.
T
H
W
N
,
C
U
.
±
6
0
'
V
.
D
=
-
0
.
2
0
%
"PC"
PANEL
1
1
/
2
"
C
-
3
#
1
&
1
#
8
G
N
D
.
T
H
W
N
,
C
U
.
±
8
0
'
V
.
D
=
-
0
.
2
4
%
M.C.B.M.C.B.M.C.B.
100A
2P
1
1
/
2
"
C
-
3
#
1
&
1
#
8
G
N
D
.
T
H
W
N
,
C
U
.
±
5
'
V
.
D
=
N
E
G
L
I
G
I
B
L
E
"HP"
PANEL
M.C.B.
#
SPECIFICATION NOTES:
1.REFER TO 'GENERAL ELECTRICAL NOTES' AND 'ELECTRICAL SYMBOLS'
ON E-0.1 AND E-0.2 FOR WIRING METHODS, MATERIALS, AND
REQUIREMENTS.
2.ALL NEW CIRCUIT BREAKERS, PANELBOARDS SHALL BE OF THE SAME
MANUFACTURER.
3.ALL GROUND CONNECTIONS SHALL BE CADWELD.
4.AVAILABLE FAULT AT SERVICE POINT SHALL BE CONSIDERED AT UTILITY
COMPANY'S FAULT CURRENT LETTER.
5.ALL NEW PANELBOARDS SHALL BE FULLY RATED FOR THE AVAILABLE
FAULT UNLESS OTHERWISE NOTED.
6.CONTRACTOR SHALL CHOOSE EQUIVALENT PRODUCT TO MATCH THE
SERIES AIC RATING PROVIDED BY UTILITY COMPANY.
REFERENCE NOTES
1.1#1/0 ELECTRODE CONDUCTOR CONNECT TO ELECTRODE RODS, AT
LEAST TWO 10' RODS AND MIN 6' EACH APART.
2.1#1/0 ELECTRODE CONDUCTOR CONNECT TO COLD WATER PIPE
WITHIN 5' OF MAIN BUILDING ENTRY.
3.1#1/0 ELECTRODE CONDUCTOR CONNECT TO UFER GROUND.
4.INTERSYSTEM BONDING BUS
5.1#1/0 ELECTRICAL BONDING JUMPER CONNECT TO THE
INTERSYSTEM BONDING BUS.
6.FIELD MARKED "CAUTION:SERIES RATED SYSTEM 42,000 AMP
AVAILABLE.
7.SERIES RATING CIRCUIT BREAKERS ON BRACH BREAKERS SHALL BE
SERIES RATED FOR 42K AIC MINIMUM.
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
TC
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S E
L
E
A
S
E 21991
LACIR
DRAWING TITLE
TRICOLOR
ENGINEERING, INC
SHEET NUMBER
E
SITE ADDRESS:
PROJECT NAME:
DESIGNER IN CHARGE
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
4403 RIVERSIDE DR.
SUITE 'A'
CHINO, CA 91710
951.454.8801
A
R
C
ESIGN
www.acrcdesigns.com
1
2
-3.1
MMMM
120/240V,2P,400A OVERHEAD
SERVICE FROM UTILITY COMPANY
Is
c
=
1
3
,
9
6
2
A
FBV FBV FBV FBV
Relay Circuit Description Switch/Sensor Comment
1
LCP
CONDUIT AND CONDUCTORS
TO CONTROLLED LIGHTING
CIRCUITS.HP
PANEL
CONDUIT AND CONDUCTORS
ARE REQUIRED FOR LIGHTING
CIRCUIT
HP-1 SIDEWALK LTG.PHOTOCELL, TIME CLOCK
PHOTOCELL ON ROOF FOR OUTDOOR LIGHTING
OR IN OFFICE FOR INDOOR LIGHTING.
PHOTOCELL ONLY CONTROLS THE LIGHTS IN
DAYLIGHT ZONE AREAS SHOWN IN E-2.2
SEE T24 REQUIREMENTS
PHOTOCELL SINGLE LINE DIAGRAM
SCALE: NONE
3
E-3.1
2
3 PA-1 WAREHOUSE LTG.PHOTOCELL, TIME CLOCK SEE T24 REQUIREMENTS
4 PB-1 WAREHOUSE LTG.PHOTOCELL, TIME CLOCK SEE T24 REQUIREMENTS
PC-1 WAREHOUSE LTG.PHOTOCELL, TIME CLOCK SEE T24 REQUIREMENTS
LOAD CALCULATION:
TOTAL LOAD: 32A*3 + 44A = 140A < 400 * 80% = 320A
400A SERVICE FOR THIS BUILDING IS OK.
HP-3 PARKING LOT LTG.PHOTOCELL, TIME CLOCK SEE T24 REQUIREMENTS
5
LCP
CONDUIT AND CONDUCTORS
TO CONTROLLED LIGHTING
CIRCUITS.
PANEL
CONDUIT AND CONDUCTORS
ARE REQUIRED FOR LIGHTING
CIRCUIT
PHOTOCELL ON ROOF FOR OUTDOOR LIGHTING
OR IN OFFICE FOR INDOOR LIGHTING.
(PA,
PB,
PC)
ROD WHEN REQUIRED.
ADDITIONAL GROUND
CONDUIT & WIRE TO
10'-0"
NO. 3 HEAVY DUTY CONCRETE
REINFORCED COVER.
THOMAS & BETTS # 2.
3/4" X 10' - 0" DRIVEN
FINISH GRADE
CONDUIT HUB FOR
GROUNDING BY
"THOMAS" & BETTS."
PRECAST 22"L. x 12" W. x 24"D
YARD BOX. BROOKS
QUICKSET # EOD22 (2 SECTIONS)
CONDUIT AND WIRE
SIZE AS REQUIRED
SEE PLANS.
GROUND FITTING
"COPPERWELD" GROUND
GROUND ROD DETAIL
SCALE: N.T.S.
2
E 3.1
2
E-3.1
1
1
1
1
1
GROUNDING NOTE:
1.THIS BUILDING IS USING SUPPLEMENTAL ELECTRODE TO FORM THE
ELECTRICAL GROUNDING SYSTEM.
2.IF MULTIPLE ROD, PIPE, OR CONCRETE-ENCASED ELECTRODE ARE
INSTALLED, THEY SHALL NOT BE LESS THAN 6 FT APART. (CEC
250.53(A)(3))
3.CONTRACTOR FIELD VERIFY AND CONFIRM THE GROUNDING
CONNECTION RESISTANCE. IF A SINGLE ROD, PIPE, OR
CONCRETE-ENCASED ELECTRODE CONNECTION RESISTANCE IS 25
OHMS OR LESS, THE SUPPLEMENTAL ELECTRODE IS NOT BE
REQUIRED.(CEC 250.53(A)(2))
2
Is
c
=
1
5
,
1
7
3
A
2
SL
O
P
E
1/4
"
:
1
2
EX
I
T
EX
I
T
EX
I
T
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,152
1 / 500 3
OFFICE
B 100
1 / 150 2
WAREHOUSE
S2 1,127
1 / 500 3
OFFICE
B 95
1 / 150 2
WAREHOUSE
S2 1,106
1 / 500 3
AL
L
E
Y
HP
THE LOCATION OF THE SERVICE GROUNDING
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
TC
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S E
L
E
A
S
E 21991
LACIR
DRAWING TITLE
TRICOLOR
ENGINEERING, INC
SHEET NUMBER
E
SITE ADDRESS:
PROJECT NAME:
DESIGNER IN CHARGE
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
4403 RIVERSIDE DR.
SUITE 'A'
CHINO, CA 91710
951.454.8801
A
R
C
ESIGN
www.acrcdesigns.com
1
2
-3.2
ELECTRICAL SITE PLAN
SCALE: 1/8"=1'
1
E-3.2
1
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
TC
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S E
L
E
A
S
E 21991
LACIR
DRAWING TITLE
TRICOLOR
ENGINEERING, INC
SHEET NUMBER
E
SITE ADDRESS:
PROJECT NAME:
DESIGNER IN CHARGE
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
4403 RIVERSIDE DR.
SUITE 'A'
CHINO, CA 91710
951.454.8801
A
R
C
ESIGN
www.acrcdesigns.com
1
2
-4.1
1
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
TC
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S E
L
E
A
S
E 21991
LACIR
DRAWING TITLE
TRICOLOR
ENGINEERING, INC
SHEET NUMBER
E
SITE ADDRESS:
PROJECT NAME:
DESIGNER IN CHARGE
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
4403 RIVERSIDE DR.
SUITE 'A'
CHINO, CA 91710
951.454.8801
A
R
C
ESIGN
www.acrcdesigns.com
1
2
-4.2
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
TC
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S E
L
E
A
S
E 21991
LACIR
DRAWING TITLE
TRICOLOR
ENGINEERING, INC
SHEET NUMBER
E
SITE ADDRESS:
PROJECT NAME:
DESIGNER IN CHARGE
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
4403 RIVERSIDE DR.
SUITE 'A'
CHINO, CA 91710
951.454.8801
A
R
C
ESIGN
www.acrcdesigns.com
1
2
-4.3
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
TC
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S E
L
E
A
S
E 21991
LACIR
DRAWING TITLE
TRICOLOR
ENGINEERING, INC
SHEET NUMBER
E
SITE ADDRESS:
PROJECT NAME:
DESIGNER IN CHARGE
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
4403 RIVERSIDE DR.
SUITE 'A'
CHINO, CA 91710
951.454.8801
A
R
C
ESIGN
www.acrcdesigns.com
1
2
-4.4
REEN
I
G
N
E
L
A
NOIS
I
C
H
E
N
AINROFIL
TC
EFORPDERETSIGER
YO N G H U
CFOET
A
T
S E
L
E
A
S
E 21991
LACIR
DRAWING TITLE
TRICOLOR
ENGINEERING, INC
SHEET NUMBER
E
SITE ADDRESS:
PROJECT NAME:
DESIGNER IN CHARGE
142 LA PORTE STREET
ARCADIA, CA. 91006
LA PORTE
WAREHOUSE
4403 RIVERSIDE DR.
SUITE 'A'
CHINO, CA 91710
951.454.8801
A
R
C
ESIGN
www.acrcdesigns.com
1
2
-4.5
LIGHT WITH OC.SENSOR AND DAYLIGHT SENSOR TIMMERDIMMER
1
EQUIPMENT MANUFACTURER, CATALOG#SERVING AREA REMARK
LIGHTING CONTROL EQUIPMENT SCHEDULE
OFFICE
LUTRON, MACL-153MDIMMER
TIMMER
WAREHOUSE, OUTDOOR
CD101
QTY.
2
3
C.J.C.J.C.J.C.J.
C.J.C.J.C.J.C.J.
1
3
2
4
"I HAVE COMPLIED WITH THE CRITERIA OF THE
ORDINANCE AND APPLIED THEM FOR THE EFFICIENT USE OF WATER
IN THE LANDSCAPE DESIGN PLANS".
20
8
0
4
REVISION BY
WA
R
E
H
O
U
S
E
LA
P
O
R
T
E
W
A
R
E
H
O
U
S
E
CL
I
E
N
T
SH
E
E
T
T
I
T
L
E
:
PR
O
J
E
C
T
:
LA
N
D
S
C
A
P
E
A
R
C
H
I
T
E
C
T
14
2
L
A
P
O
R
T
E
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
14
2
L
A
P
O
R
T
E
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
A
C
R
C
De
s
i
g
n
G
r
o
u
p
AR
C
H
I
T
E
C
T
44
0
3
R
I
V
E
R
S
I
D
E
D
R
I
V
E
SU
I
T
E
'
A
'
CH
I
N
O
,
C
A
9
1
7
1
0
95
1
.
4
5
4
.
8
8
0
1
PLANTING PLAN
SCALE: 1/8" = 1'-0"
LA
P
O
R
T
E
S
T
R
E
E
T
NORTH
PROPERTY LINE 160'
PROPERTY LINE 160'
PR
O
P
E
R
T
Y
L
I
N
E
5
0
'
PR
O
P
E
R
T
Y
L
I
N
E
5
0
'
142 LA PORTE STREET
PROPOSED 1 STORY w/ MEZZ. LEVEL
LIGHT INDUSTRIAL BUILDING
20
'
W
I
D
E
A
L
L
E
Y
3 ARB UNE
SEN REP
17 ANI HYB
15 CAL CIT
13 HES PAR
3 CLY CAL
PL
A
N
T
I
N
G
P
L
A
N
L-1
8 LAN SPP.
GRAVEL (TYP.)
3 MAG UNG
REMOVE EXIST. TREETRUNK AND STUMP
REMOVE 1 EXIST. CRAPEMYRTLE TREE
C.J.C.J.C.J.C.J.
C.J.C.J.C.J.C.J.
S
AV
AV
HUNTER IC=-101-40 L)
LOW )LOW CONTROL =ONE .ITS W PR )ILTER
*ATE VALVE-1 S
"I HAVE COMPLIED WITH THE CRITERIA OF THE
ORDINANCE AND APPLIED THEM FOR THE EFFICIENT USE OF WATER
IN THE LANDSCAPE DESIGN PLANS".
20
8
0
4
REVISION BY
WA
R
E
H
O
U
S
E
LA
P
O
R
T
E
W
A
R
E
H
O
U
S
E
CL
I
E
N
T
SH
E
E
T
T
I
T
L
E
:
PR
O
J
E
C
T
:
LA
N
D
S
C
A
P
E
A
R
C
H
I
T
E
C
T
14
2
L
A
P
O
R
T
E
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
14
2
L
A
P
O
R
T
E
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
A
C
R
C
De
s
i
g
n
G
r
o
u
p
AR
C
H
I
T
E
C
T
44
0
3
R
I
V
E
R
S
I
D
E
D
R
I
V
E
SU
I
T
E
'
A
'
CH
I
N
O
,
C
A
9
1
7
1
0
95
1
.
4
5
4
.
8
8
0
1
IRRIGATION PLAN
SCALE: 1/8" = 1'-0"
LA
P
O
R
T
E
S
T
R
E
E
T
NORTH
PROPERTY LINE 160'
PROPERTY LINE 160'
PR
O
P
E
R
T
Y
L
I
N
E
5
0
'
PR
O
P
E
R
T
Y
L
I
N
E
5
0
'
142 LA PORTE STREET
PROPOSED 1 STORY w/ MEZZ. LEVEL
LIGHT INDUSTRIAL BUILDING20
'
W
I
D
E
A
L
L
E
Y
IR
R
I
G
A
T
I
O
N
P
L
A
N
L-2
6SLEEVE INSTALATION
SCALE: N.T.S.
1/2" TO 4" IN SIZE
DIMENSION
D
C
8GATE VALVE
SCALE: N.T.S.
6"
CL
36"
A B
24"
D D D
4"
C
24"
D
A
B
OF THE PIPE OR WIRE
DETAIL ALSO FOR PIPE
INSTALLED IN ROCK SOIL.
PRESSURE MAINLINE
TWICE THE DIAMETER
PVC SLEEVES TO BE
BUNDLE CARRIED.
IN SCH 40 SLEEVE
SAND BACKFILL COMPACTED
TO THE DENSITY OF
EXISTING SOIL
IN SCH 40 SLEEVE
CONTROL WIRES
UNDISTURBED SOIL
IN SCH 40 SLEEVE
LATERAL LINES
PAVING
COVER, USE STAINLESS BOLT NUT AND WASHER.
HEAT BRAND "GV" ONTO LID.
NIPPLE, 6" LONG
SCH 80 PVC T.O.E.
3/4" CRUSHED GRAVEL
SCH 40 PVC COUPLING
IRRIGATION MAINLINE
ONE CUBIC FOOT
BRICK SUPPORTS
6" PVC CL. 160 PIPE
GATE VALVE W/HAND WHEEL
FINISHED GRADE IN SHRUB AREAS3"
PLASTIC ROUND VALVE BOX WITH BOLT DOWN
3
7
5
4
2
1 FINISH GRADE
PVC DRIP MANIFOLD PIPE
PVC 1" X 34" TRUE UNION BALL VALVE
1 2 3 4
6
5 6
7 8 8
5SUB-SURFACE FLUSH POINT WITH BALL VALVE
SCALE: N.T.S.
13 SUB-SURFACE IRREGULAR SHAPED LAYOUT
SCALE: N.T.S.
9RAIN SENSOR
SCALE: N.T.S.
1" ABOVE GRADE
ROOTBALL, SET CROWN
FINISH GRADE
PLANTING GROUND COVER]
[RAKE SMOOTH PRIOR TO
EARTH WATERING BASIN
DIA
ROOTBALL
2x
DIA
ROOTBALL
2x
SHRUB
PLANT TABLETS PER
SPECIFICATIONS
_1_" DEEP MULCH
12"
V.I.T. TWIST BRACE
BETWEEN STAKE & TREE
2" DIA X 10' LONG
LODGE POLE STAKES
PLANT TABLETS PER
SPECIFICATIONS
PLANT TREES/SHRUBS SO TOP
OF ROOT CROWN IS 1" ABOVE
SOIL (NOT AMENDED)
ROOTBALL, SET CROWN
1" ABOVE GRADE
SURROUNDING FINISH GRADE
2TREE PLANTING DETAIL
SCALE:N.T.S.
3SHRUB PLANTING DETAIL
SCALE:N.T.S.
LEGEND:
OPENED FACE PLATE
1 2 3
4
5
6
7
1
SENSOR INPUTS2
SCREEN3
CONTROL WIRES4
TRANSFORMER5
6
7
NOTE
MOUNT CONTROLLER LCD SCREEN AT EYE
LEVEL, CONTROLLER SHALL BE HARD-WIRED TO
GROUNDED
110 VAC POWER SOURCE
IRRIGATION CONTROL WIRE IN CONDUIT
SIZE AND TYPE PER LOCAL CODES
ELECTRICAL SUPPLY CONDUIT
CONNECT TO POWER SOURCE, J-BOX INSIDE
CONTROLLER
1IRRIGATION CONTROLLER
SCALE: N.T.S.
EQUAL
SPACING
EQUAL
SPACINGSP
A
C
I
N
G
EQ
.
4GROUNDCOVER PLANTING
SCALE:N.T.S.
HARDSCAPE
18"
APPROX.4" (10.1 CM)
HARDSCAPE
2
1
3
4
5
6
LEGEND:
1
2
HUNTER DRIPLINE PER PLAN
ECO-INDICATOR ON SWING ARM
AIR RELIEF VALVE IN VALVE BOX
PLD OR PLD-LOCK FITTING (TYP.)
4
5
DRIP CONTROL ZONE KIT PER
PLAN
3
FLUSH POINT (PLD-BV) IN
SUBTERRANEAN
BOX PER PLAN
6
NOTES
AIR RELIEF VALVE (PLD-AVR) INSTALLED IN
VALVE BOX AT OPTIMAL HIGHEST POINT FROM
CONTROL ZONE KIT. MULTIPLE AIR RELIEF VALVES
MAY BE NEEDED TO ACCOMMODATE DIFFERENCES IN
GRADE.
ECO-INDICATOR TO BE INSTALLED AT OPTIMAL FURTHEST
POINT FROM CONTROL ZONE KIT IN CLEAR VIEW WHEN
POPPED UP.
FLUSH POINT TO BE INSTALLED AT OPTIMAL FURTHEST
POINT FROM CONTROL ZONE KIT TO ALLOW FOR MAXIMUM
DEBRIS FLUSH IN SYSTEM.
18"
1
2
LEGEND:
HUNTER DRIPLINE (HDL) PER PLAN
3
6
PVC RISER - SIZE AND LENGTH AS
REQUIRED
PLD OR PLD-LOC FITTING
FINISHED GRADE
4 MULCH (AS SPECIFIED)
7
SOIL
8 PVC SUPPLY HEADER - SIZE PER PLAN
DEPTH PER PLAN 5 PVC TEE
1
2
3
5
6
7
8
4
11 SUBSURFACE DRIPLINE INSTALLATION
SCALE: N.T.S.
LEGEND
10DRIP ZONE KIT: 3/4" REMOTE CONTROL VALVE
SCALE: N.T.S.
2
12QUICK COUPLER VALVE
SCALE: N.T.S.
PVC SCH 80 NIPPLE
QUICK-COUPLING VALVE:
1
1 2 3
4
5
11
6
7 9 8 7
4
2
3
5
4
6
VALVE BOX WITH COVER:
10
1110
7
8
9
HUNTER HQ-33 DRC
FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO
3-INCH MINIMUM DEPTH OF
(LENGTH AS REQUIRED)
3/4-INCH WASHED GRAVEL
BRICK (1 OF 2)
PVC SCH 40 STREET ELL
PVC SCH 40 TEE OR ELL
PVC MAINLINE PIPE
PVC SCH 40 ELL
FINISH GRADE/TOP OF MULCH
2" x 2" REDWOOD STAKE WITH
STAINLESS STEEL GEAR
CLAMPS OR EQUIVALENT
SUPPORT SYSTEMNOTE:
NOMINAL QUICK COUPLING VALVE INLET SIZE.
1
2
3
4
1
2
LEGEND:
AIR RELIEF VALVE
3
4 PLD-075-TBTEE FITTING
FINISHED GRADE
3/4" MPT X 1/2" FPT BUSHING
NOTES
AIR RELIEF VALVE TO BE INSTALLED AT
OPTIMAL HIGHEST POINT FROM
CONTROL ZONE KIT. MULTIPLE AIR
RELIEF VALVES MAY BE NEEDED TO
ACCOMMODATE DIFFERENCES IN GRADE.
5
5 PROFESSIONAL LANDSCAPE DRIPLINE
6
7
6 FILTER FABRIC
7 BRICK
7AIR RELIEVE VALVE
SCALE: N.T.S.
WIRELESS RAIN SENSOR
WALL MOUNT CONTROLLER
POST OR SUITABLE MOUNTING SURFACE, HEIGHT
PER PLAN
FINISHED GRADE
DETAIL LEGEND:
1
2
3
4
1
4
3
2
PLANT SHRUBS SO TOP
OF ROOT CROWN IS 1" ABOVE
SURROUNDING FINISH GRADE
141"REDUCED PRESSURE BACKFLOW PREVENTION ASSEMBLY
SCALE:N.T.S.
3. WHEN UNIT IS NEXT TO BUILDING, WALL, ETC.
LEAD PRIMER AND ONE (1) COAT PAINT.
2. ALL ABOVE GROUND ASSEMBLY SHALL RECEIVE ONE (1) COAT RED
BUILDINGS, ETC.
1. EQUIPMENT TO BE INSTALLED AT A MINIMUM OF 12" FROM WALLS,
NOTE:
TEST COCKS ARE TO BE ON OUTSIDE.
12" Min
LINE - DISCHARGE
PRESSURE SUPPLYTHRUST BLOCK (TYP.)
12" SQ. CONCRETE
METAL PIPE
INTAKE
SUPPLY LINE
PRESSURE
FINISH GRADE
UNION
REDUCED PRESSURE
BACKFLOW DEVICE
BRASS ELBOW
(TYP.)
ADAPTERSCH 40 MALE
NIPPLE PVC12" BRASS
18
"
INSTALL WITH STRONG BOX ENCLOSURE SBBC-30SS&CR
ENCLOSURE
"I HAVE COMPLIED WITH THE CRITERIA OF THE
ORDINANCE AND APPLIED THEM FOR THE EFFICIENT USE OF WATER
IN THE LANDSCAPE DESIGN PLANS".
20
8
0
4
REVISION BY
WA
R
E
H
O
U
S
E
LA
P
O
R
T
E
W
A
R
E
H
O
U
S
E
CL
I
E
N
T
SH
E
E
T
T
I
T
L
E
:
PR
O
J
E
C
T
:
LA
N
D
S
C
A
P
E
A
R
C
H
I
T
E
C
T
14
2
L
A
P
O
R
T
E
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
14
2
L
A
P
O
R
T
E
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
A
C
R
C
De
s
i
g
n
G
r
o
u
p
AR
C
H
I
T
E
C
T
44
0
3
R
I
V
E
R
S
I
D
E
D
R
I
V
E
SU
I
T
E
'
A
'
CH
I
N
O
,
C
A
9
1
7
1
0
95
1
.
4
5
4
.
8
8
0
1
PL
A
N
T
I
N
G
A
N
D
IR
R
I
G
A
T
I
O
N
D
E
T
A
I
L
S
L-3
"I HAVE COMPLIED WITH THE CRITERIA OF THE
ORDINANCE AND APPLIED THEM FOR THE EFFICIENT USE OF WATER
IN THE LANDSCAPE DESIGN PLANS".
20
8
0
4
REVISION BY
WA
R
E
H
O
U
S
E
LA
P
O
R
T
E
W
A
R
E
H
O
U
S
E
CL
I
E
N
T
SH
E
E
T
T
I
T
L
E
:
PR
O
J
E
C
T
:
LA
N
D
S
C
A
P
E
A
R
C
H
I
T
E
C
T
14
2
L
A
P
O
R
T
E
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
14
2
L
A
P
O
R
T
E
S
T
R
E
E
T
AR
C
A
D
I
A
,
C
A
A
C
R
C
De
s
i
g
n
G
r
o
u
p
AR
C
H
I
T
E
C
T
44
0
3
R
I
V
E
R
S
I
D
E
D
R
I
V
E
SU
I
T
E
'
A
'
CH
I
N
O
,
C
A
9
1
7
1
0
95
1
.
4
5
4
.
8
8
0
1
L-4
SP
E
C
I
F
I
C
A
T
I
O
N
S
CALL TOLL FREE
1-800 227-2600
SERVICE ALERT
BEFORE YOU DIG
UNDERGROUND
TWO WORKING DAYS
ENGINEER'S NOTE TO CONTRACTOR:SOIL ENGINEER & PREPARED FORENGINEERING GEOLOGIST
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES,
CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS
DURING THE COURSE OF THE CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS
REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION
CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY, AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY LIABILITY, REAL
OR ALLEGED, IN CONNECTION OF THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF DESIGN PROFESSIONAL. THE EXISTENCE AND LOCATION OF OF ANY UNDERGROUND UTILITIES OR STRUCTURES
SHOWN IN THESE PLANS WERE OBTAINED FROM BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE
ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL
PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY
DAMAGE TO THESE LINES OR STRUCTURES.
DATEREVISIONS NO.
PROPOSED 1-STORY
PROJECT ADDRESS:
142 LA PORTE STREET, ARCADIA, CA 91006
PROJECT :
JOB NO.SHEET NAME:
UNDER THE SUPERVISION OF:
DATEGIL B. BERMEJO RCE 86264
MR. LEE CHAN & DON GABRIEL
CONTACT:
NAME:
ADDRESS:
TEL. NO.:
9428 ETON AVE. UNIT M, CHATSWORTH
818-341-1899
C.Y. GEOTECH, INC
CALIFORNIA 91311
JOB NO.: CYG-22-9538
CONTACT: PAUL CAI, P.E.
EMAIL: cygeotech@sbcglobal.net
DATED: JULY 8, 2022
Engineering Geology & Geotechnical Engineering
LA PORTE WAREHOUSE
No. 86264
IC I LV
G I L B E RM
E
J
O
Exp. 03-31-25
02/21/24
CLIENT/OWNER:
TEL. NO. : 415-531-0055
MR. LEE CHAN
CITY OF ARCADIA
DEVELOPMENT SERVICES DEPARTMENT
BUILDING DIVISION
Z-22-0370
7343 SANTA ELISE CIRCLE, BUENA PARK, CALIFORNIA 90620
ENGINEERING & SURVEYING, INC
TEL. NO. : 714-576-7725 EMAIL : info@zenithcels.com
ZENiTH
ARCHITECTURE ENGINEERING SURVEYING CONSTRUCTION
EMAIL : danielsdisplay@icloud.com C-1
GENERAL GRADING NOTES
& EROSION CONTROL NOTES
CITY OF ARCADIA
GRADING AND DRAINAGE PLAN
142 LA PORTE STREET
GENERAL INFORMATION
• GRADING PERMIT APPLICATION NO. _____________________________ *
• EARTHWORK VOLUMES CUT____________(CY), FILL____________ (CY) *
OVER EXCAVATION/ ALLUVIAL REMOVAL & COMPACTION _____________ (CY) *
FILL ___________(CY), EXPORT LOCATION: ___________________________ *
• TOTAL DISTURBED AREA __________________ (ACRES) *
• TOTAL PROPOSED LANDSCAPE AREA __________________ SQUARE FEET *
• TOTAL TURF AREA _________% (PERCENT OF TOTAL PROPOSED LANDSCAPING) *
• TOTAL DROUGHT TOLERANT LANDSCAPING AREA ________ % (PERCENT OF TOTAL PROPOSED LANDSCAPING) *
• PRE-DEVELOPMENT IMPERVIOUS AREA ___________________ (ACRES) *
• POST-DEVELOPMENT IMPERVIOUS AREA ___________________ (ACRES) *
• WASTE DISCHARGE IDENTIFICATION NUMBER (WDID #) _________________________________
CONSTRUCTION & DEMOLITION DEBRIS RECYCLING AND REUSE PLAN (RPP ID) ________________ *
POST-CONSTRUCTION BMP FEATURE(s) GPS COORDINATES X ______________, Y______________
PROPERTY INFORMATION
• PROPERTY ADDRESS ____________________________________________________
• TRACT / PARCEL MAP NO. _______________________________ LOT/PARCEL NO. ____________
• PROPERTY OWNER _________________________________________ *
• ASSESSORS ID NUMBER(S) ____________________________________ *
ZONING, REGIONAL PLANNING, AND OTHER AGENCY INFORMATION
• PROPERTY ZONING: ________________________________________ *
• INTENDED LAND USE: _______________________________________________________ *
(FOR PROPOSED GRADED AREAS - I.E. ... SINGLE FAMILY RESIDENCE )
• CERTIFICATE OF COMPLIANCE: CC NO._________________________
• PLOT PLAN NUMBER: PP NO._________________________________
• CONDITIONAL USE PERMIT: CUP NO.______________________ EXPIRATION DATE: _______________
• OAK TREE PERMIT NUMBER: OTP NO.________________________ EXPIRATION DATE: _______________
• COMMUNITY STANDARDS DISTRICT:_____________________________
• CALIFORNIA COASTAL COMMISSION AREA: _________YES, ________NO APPROVED VOLUME: ____________(CY)
• COASTAL DEVELOPMENT PERMIT CDP___________________________ EXPIRATION DATE: _______________
• FISH & GAME, ARMY CORP OF ENGINEERS, REGIONAL WATER CONTROL BOARD, AQMD & OTHER AGENCY PERMITS
SHOULD BE ADDED
AS APPLICABLE. (PERMIT NUMBER________________, EXPIRATION DATE_________________________)
PROJECT INFORMATION:
CM
COMMERCIAL MANUFACTURING
N/A
N/A
N/A
N/A
X
N/A
N/A
N/A
N/A
N/A N/A
0.18
850.00
0.00
25
0.098
0.164
N/A
N/A
N/A
80.00 150.00
N/A
LOT 26 BLK 81ARCADIA SANTA ANITA TRACT
5773-004-015
450.00
70.00
N/A
MR. LEE CHAN & DON GABRIEL
VICINITY MAP
GRADING & DRAINAGE PLAN
TITLE SHEET
INDEX OF DRAWINGS:
C-1
C-2
C-3
EROSION & SEDIMENT CONTROL NOTES
EROSION & SEDIMENT CONTROL PLAN
EROSION & SEDIMENT CONTROL DETAILS (TC-1)
ESCP-1
ESCP-2
ESCP-3
LOW IMPACT DEVELOPMENT PLAN
ESCP-4EROSION & SEDIMENT CONTROL DETAILS (WM-8)
EROSION & SEDIMENT CONTROL DETAILS (WM-3 & SE-8)ESCP-5
EROSION & SEDIMENT CONTROL DETAILS (WM-9 & SE-7)ESCP-6
142 LA PORTE ST., ARCADIA, CA 91006
LEGAL DESCRIPTION:
THE LAND REFERRED TO IN THIS SURVEY IS SITUATED IN THE STATE OF CALIFORNIA, COUNTY
OF LOS ANGELES, AND IS DESCRIBED AS FOLLOWS:
LOT 26 BLOCK 81 OF A PART OF ARCADIA SANTA ANITA TRACT, IN THE COUNTY OF LOS
ANGELES AS SHOWN ON MISCELLANEOUS RECORDS IN BOOK 15 PAGES 89 TO 90 OF MAPS, IN
THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY.
APN : 5773-004-015
BASIS OF BEARINGS:
LAND AREA:
CONTAINING AN AREA OF 8,003.06 SQ. FT., OR 0.1837 ACRES, MORE OR LESS.
BENCHMARK:
THE BEARING NORTH 89° 59' 09" EAST, ON THE CENTERLINE OF LA PORTE STREET AS SHOWN
ON RECORD OF SURVEY MAP BOOK 77 PAGE 69, IN THE CITY OF ARCADIA, COUNTY OF LOS
ANGELES, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY.
ASSUME BENCH MARK : LEAD & TACK IN 2ND AVENUE COR. LA PORTE STREET
DESCRIPTION : L&T ON NW COR. OF 2ND AVE. AND LA PORTE ST. INTER., NE OF PROPERTY
ASSUME ELEVATION : 100.00 FEET
DETAILS & SECTIONS
C-4
1. ALL WORK SHOWN HEREON SHALL BE DONE IN ACCORDANCE WITH THE CITY OF ARCADIA STANDARDS AND
SPECIFICATIONS, AND APPENDIX J OF THE 2019 CALIFORNIA BUILDING CODE.
2. PRIOR TO THE START OF GRADING ALL EXISTING VEGETATION AND DEBRIS. INCLUDING EXISTING STRUCTURES.
FOOTINGS, FOUNDATIONS, RUBBLE, TREES, AND ROOT SYSTEMS SHALL BE REMOVED FROM THE SITE TO THE
SATISFACTION OF THE SOILS ENGINEER.
3. REMOVAL OF DEBRIS. EXISTING FILL AND DISTURBED NATURAL SOILS SHALL BE EXCAVATED TO THE
SATISFACTION OF THE SOILS ENGINEER.
4. THE SOILS ENGINEER SHALL THEN INSPECT THE EXPOSED SOILS, AND ANY ADDITIONAL OVER EXCAVATION
SHALL THEN BE MADE IN ACCORDANCE WITH THE SOILS ENGINEERS RECOMMENDATIONS AND AS CONTAINED
IN THE SOILS REPORT.
5. THE EXPOSED SOILS SHALL THEN BE SCARIFIED TO A MINIMUM DEPTH OF 6 INCHES, BROUGHT TO PROPER
MOISTURE CONTENT AND COMPACTED TO AT LEAST 90 % OF THE MAXIMUM DENSITY, AS DETERMINED BY
APPENDIX J OF THE 2019 CALIFORNIA BUILDING CODE OR EQUIVALENT COMPACTION SHALL BE OBTAINED BY
METHODS SPECIFIED BY THE SOILS ENGINEER.
6. IF ANY UNFORESEEN SUBSURFACE STRUCTURES ARE ENCOUNTERED DURING CONSTRUCTION THEY SHALL BE
IMMEDIATELY BROUGHT TO THE ATTENTION OF THE SOILS ENGINEER AND BUILDING DEPARTMENT BEFORE
PROCEEDING FURTHER.
7. THE CONTRACTOR SHALL TAKE PROTECTIVE MEASURES SO AS NOT TO CAUSE ANY MUD, SILT OR DEBRIS TO BE
DEPOSITED ONTO PUBLIC OR ADJACENT PROPERTY AT ALL TIMES DURING CONSTRUCTION. ANY MUD OR
DEBRIS ON PUBLIC PROPERTY SHALL BE REMOVED IMMEDIATELY; DUST SHALL BE CONTROLLED BY WATERING
OR OTHER APPROVED METHOD THROUGHOUT THE GRADING AND BUILDING CONSTRUCTION OPERATION.
8. PRIOR TO THE START OF ANY BUILDING CONSTRUCTION THE CONTRACTOR SHALL FURNISH THE CITY WITH
CERTIFICATIONS FROM THE CIVIL ENGINEER AND SOILS ENGINEER THAT BUILDING PAD SUBGRADES ARE
WITHIN 0 10 FOOT OF THE APPROVED PLANS AND THAT THE PROPER COMPACTION HAS BEEN OBTAINED.
9. NO GRADING SHALL COMMENCE WITHOUT OBTAINING A GRADING PERMIT AND NOTIFYING THE BUILDING
INSPECTOR 24 HOURS PRIOR TO START OF WORK.
10. RESPONSIBILITY FOR GRADING AND INSPECTION SHALL BE ASSUMED BY THE ENGINEER OF RECORD IN
ACCORDANCE WITH APPENDIX J OF THE 2019 CALIFORNIA BUILDING CODE.
11. THE SOILS ENGINEER SHALL ALSO BE RESPONSIBLE TO VERIFY AND REPORT THAT PROPER COMPACTION HAS
BEEN OBTAINED BY SUBCONTRACTOR AND AGENCIES CONCERNING UTILITY LINE BACKFILL INCLUDING, BUT
NOT LIMITED TO SEWERS, WATER LINES, ELECTRICAL, GAS AND LANDSCAPE IRRIGATION LINES.
12. CERTIFICATES OF FINAL LOT GRADING ARE TO BE SUBMITTED TO THE BUILDING AND SAFETY DIVISION PRIOR
TO THE FINAL BUILDING INSPECTION.
13. AN "AS-BUILT' GRADING PLAN AND CERTIFICATION OF COMPLIANCE WITH SAID GRADING PLAN IS TO BE
SUBMITTED TO THE BUILDING AND SAFETY DIVISION PRIOR TO RELEASE OF GRADING BOND AND PRIOR TO
FINAL GRADING INSPECTION.
14. ALL SLOPES EXCEEDING 5' IN VERTICAL HEIGHT AND EXCEEDING 5:1 SLOPE ARE TO BE PLANTED WITH
APPROVED PLANT MATERIAL AND PROVIDED WITH APPROVED WATERING SYSTEM.
15. NO ADJUSTMENT OF ELEVATION SHALL BE MADE WITHOUT PRIOR WRITTEN APPROVAL OF THE BUILDING
OFFICIAL AND THE CIVIL ENGINEERING OF RECORD,
16. ALL P.C.C. WATER CARRYING DEVICES WITH MINIMUM SLOPES LESS THAN 0.5% WILL BE WATER TESTED PRIOR
TO THE FINAL FINISH. ANY RESIDUAL PONDING IN EVIDENCE AT TIME OF INSPECTION SHALL BE CAUSE FOR
REMOVAL AND REPLACEMENT.
17. ALL WALLS OVER 3 FT. IN FINISH HEIGHT REQUIRE SEPARATE PERMITS AND INSPECTION.
18. ALL WORK WITHIN THE PUBLIC RIGHT OF WAY REQUIRES PERMITS AND INSPECTION ISSUED BY THE
ENGINEERING DIVISION.
19. IN THE EVENT THAT THE PROJECT EXCAVATES ANY PORTION OF A CITY STREET THAT IS LISTED UNDER THE
CITY'S 5 YEAR PAVEMENT REHABILITATION MORATORIUM AT THE TIME OF EXCAVATION, THE OWNER AND/OR
DEVELOPER WILL BE RESPONSIBLE FOR REPAVING THE STREET FULL WIDTH FROM PROPERTY LINE TO
PROPERTY LINE OR TO THE CITY ENGINEER'S SATISFACTION PRIOR TO FINAL PROJECT ACCEPTANCE.
20. GRADING CONTRACTOR SHALL NOTIFY THE SOILS ENGINEER NOT LESS THAN 72 HR. IN ADVANCE OF THE
LOCATION OF ANY SOILS PROPOSED FOR IMPORT, EACH PROPOSED IMPORT SOURCE SHALL BE SAMPLED,
TESTED. AND APPROVED PRIOR TO DELIVERY OF SOILS FOR USE ON THE SITE.
21. WE HEREBY CERTIFY THAT WE HAVE REVIEWED THIS PLAN AND THAT IT CONFORMS TO SOILS REPORT
NO. ________________ DATED _________________ AND LETTER OR REVIEW FOR _____________________________
DATED_______________ SOILS REPORT NO. ______________
PREPARED BY: _________________________
STATE LIC. NO. R.C.E. _____________________
22. THE UNDERSIGNED CIVIL ENGINEER WILL BE RESPONSIBLE FOR PROFESSIONAL INSPECTION IN ACCORDANCE
WITH APPENDIX J OF THE 2019 CALIFORNIA BUILDING CODE.
_______________________ STATE LIC. NO. C.E. __________________
1. ALL GRADING SHALL CONFORM TO ARTICLE VIII, CHAPTER I, PART 1, SECTION 8110 OF THE CITY OF
ARCADIA MUNICIPAL CODE.
2. CUT AND FILL
A. MAXIMUM CUT SLOPE OF BE 2:1.
B. MAXIMUM FILL SLOPE TO BE 2:1.
3. INDICATE LOCATION OF MAXIMUM CUT AND FILL.
4. ALL FILL AND FILL SLOPE TO BE COMPACTED TO NOT LESS THAN NINETY (90%) OF MAXIMUM
DENSITY.
5. NO GRADING SHALL COMMENCE UNTIL GRADING PERMIT HAS BEEN ISSUED BY THE CHIEF OF
BUILDING OFFICIAL.
6. ESTIMATED PERIOD FOR COMPLETION OF GRADING:
GRADING WILL BEGIN: _________________________
TO BE COMPLETED BY: _________________________
7. OBTAIN PERMIT FROM CITY OF ARCADIA CITY ENGINEER FOR ALL WORK
8. REMOVE AND REPLACE DEFICIENT OR DAMAGED CURB AND GUTTER SIDEWALK AND/OR
PAVEMENT TO THE SATISFACTION OF THE CITY INSPECTOR.
9. CONTACT PUBLIC WORKS INSPECTOR AT (626) 254-2725, AT LEAST 24 HOURS PRIOR TO
CONSTRUCTION OF OFF-SITE IMPROVEMENTS. ALL OFF-SITE IMPROVEMENTS SHALL BE
COMPLETED TO THE SATISFACTION OF THE PUBLIC WORKS SERVICES DIRECTOR PRIOR TO FINAL
INSPECTION BY THE BUILDING AND SAFETY DIVISION AND PRIOR TO ACCEPTANCE
10. CONTRACTOR SHALL COMPLY WITH ALL REQUIREMENTS OF FEDERAL, STATE, AND LOCAL LAWS
AND REGULATIONS PERTAINING TO THE CLEAN AIR AND CLEAN WATER ACT.
11. SOILS ENGINEER WILL INSPECT THE EXCAVATION AT THE BOTTOM OF OVER-EXCAVATION TO
DETERMINE THAT THE SOILS IS ADEQUATE PRIOR TO RECOMPACTION.
GENERAL NOTES:GRADING NOTES:
CYG-22-9434 JULY 8, 2022 142 LA PORTE ST, ARCADIA
CYG-22-9538
C80352
CY GEOTECH, INC
C80352MR. LUO B. CAI (PAUL CAI)
MARCH 01, 2024
MARCH 31, 2024
JULY 8, 2022
118.72
ROOF ELEV.
117.31
ROOF ELEV.
48"Ø TREE
24"Ø TREE
18"Ø TREE
12"Ø TREE
102.26TC
101.78FL
102.34 TOP "X"101.90FL
101.72BOT "X"
101.80BOT "X"
102.37 TOP "X"
101.93FL
102.46TC
101.95FL
102.58TC
102.07FL
102.71TC
102.28FL
102.92
102.56102.57
102.49 102.54
102.48
102.32
102.30102.43
102.44
102.14
102.21
102.47
102.65
102.87
102.76
102.68102.74
102.67 102.70
102.54TC 102.68TC
102.19
102.30
102.37
102.40
102.08
102.20
102.49 102.56 103.60
104.34
104.30
104.53FF
104.27
103.41
102.48
102.81
102.77
102.63
102.45
102.59 102.50
102.68102.72
102.69
102.74
102.63
102.04
105.64TW105.86TW
18"Ø TREE
36"Ø TREE
124.77
103.03
102.96
102.87
102.83102.90
102.76
102.59 102.43
102.51102.61
102.66
102.81
103.03103.18
102.73
102.75
102.68102.73
104.24
102.72
107.15TW
107.15TW
105.81TW
105.73TW 108.44TW
101.31
104.04
102.23
102.22 104.15
104.48FF
102.22
102.17
102.17102.04101.88101.82101.61
101.63101.46101.40101.30101.34
101.37
101.49
101.40
101.36 101.38
101.38 101.50
101.68
101.86
101.95
101.94
102.02
102.04
101.91
102.09
102.22
102.28 102.37
102.26
102.27
102.17
102.04
101.53
101.40
101.52
101.58
101.88
102.04
102.12
102.22
101.32
101.35
101.32101.47101.34
101.48 101.39
101.33
101.34101.38
101.95
101.94102.10FF
101.36
101.48
101.49
101.34
101.41
101.42101.23101.07
101.08
107.26TW 101.28
101.20
101.10
100.91
101.26101.27
101.33101.17
101.43
101.32 101.48
101.44
101.33
101.26
101.16
101.13
101.01
100.88
100.90
100.86
100.75100.74
10
0
.
8
5
10
0
.
8
2
10
0
.
7
7
10
0
.
9
9
10
0
.
9
6
10
0
.
9
1
10
1
.
1
3
10
1
.
0
7
10
1
.
1
4
101.44
101.30
101.20
101.07
100.92
100.93
100.91
100.83
C/
L
LA
P
O
R
T
E
S
T
R
E
E
T
C/
L
A
L
L
E
Y
102.61
APN : 5773-004-015
APN : 5773-004-027
2-STORY BLDG
STORAGE
SHED
APN : 5773-004-014
1-STORY HOUSE
WAREHOUSE
1-STORY HOUSE
@ 103.15 FF
C/LFIRST AVENUE
C/L
SECOND AVENUE
CALL TOLL FREE
1-800 227-2600
SERVICE ALERT
BEFORE YOU DIG
UNDERGROUND
TWO WORKING DAYS
ENGINEER'S NOTE TO CONTRACTOR:SOIL ENGINEER & PREPARED FORENGINEERING GEOLOGIST
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES,
CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS
DURING THE COURSE OF THE CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS
REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION
CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY, AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY LIABILITY, REAL
OR ALLEGED, IN CONNECTION OF THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF DESIGN PROFESSIONAL. THE EXISTENCE AND LOCATION OF OF ANY UNDERGROUND UTILITIES OR STRUCTURES
SHOWN IN THESE PLANS WERE OBTAINED FROM BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE
ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL
PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY
DAMAGE TO THESE LINES OR STRUCTURES.
DATEREVISIONS NO.
PROPOSED 1-STORY
PROJECT ADDRESS:
142 LA PORTE STREET, ARCADIA, CA 91006
PROJECT :
JOB NO.SHEET NAME:
UNDER THE SUPERVISION OF:
DATEGIL B. BERMEJO RCE 86264
MR. LEE CHAN & DON GABRIEL
CONTACT:
NAME:
ADDRESS:
TEL. NO.:
9428 ETON AVE. UNIT M, CHATSWORTH
818-341-1899
C.Y. GEOTECH, INC
CALIFORNIA 91311
JOB NO.: CYG-22-9538
CONTACT: PAUL CAI, P.E.
EMAIL: cygeotech@sbcglobal.net
DATED: JULY 8, 2022
Engineering Geology & Geotechnical Engineering
LA PORTE WAREHOUSE
No. 86264
IC I LV
G I L B E RM
E
J
O
Exp. 03-31-25
02/21/24
CLIENT/OWNER:
TEL. NO. : 415-531-0055
MR. LEE CHAN
CITY OF ARCADIA
DEVELOPMENT SERVICES DEPARTMENT
BUILDING DIVISION
Z-22-0370
7343 SANTA ELISE CIRCLE, BUENA PARK, CALIFORNIA 90620
ENGINEERING & SURVEYING, INC
TEL. NO. : 714-576-7725 EMAIL : info@zenithcels.com
ZENiTH
ARCHITECTURE ENGINEERING SURVEYING CONSTRUCTION
EMAIL : danielsdisplay@icloud.com
GRADING & DRAINAGE PLAN
A
C-3
( IN FEET )
1 inch = ft.
GRAPHIC SCALE
0
8
84 16
C-2
CONSTRUCTION NOTES
1
2
3
3 4
5
5 6
6
7 7
7 7
8
9
9 9
99
10
10 10 10 10
10
11
11
11
1414
16
15
14
17
1212
121213
13
13
18
2
BC-
3
13
2-4"Ø 2-4"Ø
20
21
19
22
23
23 23
23
24
25
90.00
100.00
110.00
120.00
90.00
100.00
110.00
120.00PLC/L
A
L
L
E
Y
PL PL C/L
LA
P
O
R
T
E
S
T
.
90.00
100.00
110.00
120.00 PL PL
CALL TOLL FREE
1-800 227-2600
SERVICE ALERT
BEFORE YOU DIG
UNDERGROUND
TWO WORKING DAYS
ENGINEER'S NOTE TO CONTRACTOR:SOIL ENGINEER & PREPARED FORENGINEERING GEOLOGIST
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES,
CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS
DURING THE COURSE OF THE CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS
REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION
CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY, AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY LIABILITY, REAL
OR ALLEGED, IN CONNECTION OF THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF DESIGN PROFESSIONAL. THE EXISTENCE AND LOCATION OF OF ANY UNDERGROUND UTILITIES OR STRUCTURES
SHOWN IN THESE PLANS WERE OBTAINED FROM BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE
ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL
PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY
DAMAGE TO THESE LINES OR STRUCTURES.
DATEREVISIONS NO.
PROPOSED 1-STORY
PROJECT ADDRESS:
142 LA PORTE STREET, ARCADIA, CA 91006
PROJECT :
JOB NO.SHEET NAME:
UNDER THE SUPERVISION OF:
DATEGIL B. BERMEJO RCE 86264
MR. LEE CHAN & DON GABRIEL
CONTACT:
NAME:
ADDRESS:
TEL. NO.:
9428 ETON AVE. UNIT M, CHATSWORTH
818-341-1899
C.Y. GEOTECH, INC
CALIFORNIA 91311
JOB NO.: CYG-22-9538
CONTACT: PAUL CAI, P.E.
EMAIL: cygeotech@sbcglobal.net
DATED: JULY 8, 2022
Engineering Geology & Geotechnical Engineering
LA PORTE WAREHOUSE
No. 86264
IC I LV
G I L B E RM
E
J
O
Exp. 03-31-25
02/21/24
CLIENT/OWNER:
TEL. NO. : 415-531-0055
MR. LEE CHAN
CITY OF ARCADIA
DEVELOPMENT SERVICES DEPARTMENT
BUILDING DIVISION
Z-22-0370
7343 SANTA ELISE CIRCLE, BUENA PARK, CALIFORNIA 90620
ENGINEERING & SURVEYING, INC
TEL. NO. : 714-576-7725 EMAIL : info@zenithcels.com
ZENiTH
ARCHITECTURE ENGINEERING SURVEYING CONSTRUCTION
EMAIL : danielsdisplay@icloud.com
GRADING & DRAINAGE PLAN
C-3
NDS ATRIUM GRATE WITH NDS SPEE-D BASIN
NOT TO SCALE
SURFACE AREA
PLANTER AREA
CONC. V-GUTTER DETAIL
NTS
WAREHOUSE
1-STORY HOUSE
@ 103.15 FF
SECTION A-A
SCALE 1" = 10'
SECTION B-B
SCALE 1" = 10'
118.72
ROOF ELEV.
117.31
ROOF ELEV.
48"Ø TREE
24"Ø TREE
18"Ø TREE
12"Ø TREE
102.26 TC
101.78FL
102.34 TOP "X"
101.90FL
101.72BOT "X"
101.80BOT "X"
102.37 TOP "X"
101.93FL
102.46TC
101.95FL
102.58TC102.07FL
102.56102.57
102.49 102.54
102.48
102.32
102.30102.43
102.44
102.21
102.47
102.65
102.76
102.68102.74
102.67 102.70
102.54TC 102.68TC
102.19
102.30
102.37
102.40
102.08
102.20
102.49 102.56 103.60
104.34
104.30
104.53FF
104.27
103.41
102.48
102.81
102.77
102.63
102.45
102.59 102.50
102.68102.72
102.69
102.74
102.63
102.04
105.64 TW105.86TW
18"Ø TREE
36"Ø TREE
102.96
102.87
102.83102.90
102.76
102.59 102.43
102.51102.61
102.66
102.81
103.03103.18
102.73
102.75
102.68102.73
104.24
102.72
107.15TW
107.15TW
105.81TW
105.73TW 108.44 TW
101.31
104.04
102.23
102.22 104.15
104.48FF
102.22
102.17
102.17102.04101.88101.82101.61
101.63101.46101.40101.30101.34
101.37
101.49
101.40
101.36 101.38
101.38 101.50
101.68
101.86
101.95
101.94
102.02
102.04
101.91
102.09
102.22
102.28 102.37
102.26
102.27
102.17
102.04
101.53
101.40
101.52
101.58
101.88
102.04
102.12
102.22
101.32
101.35
101.32101.47101.34
101.48 101.39
101.33
101.34101.38
101.95
101.94102.10FF
101.36
101.48
101.49
101.34
101.41
101.42101.23101.07
101.08
107.26TW 101.28
101.20
101.10
100.91
101.26101.27
101.33101.17
101.43
101.32 101.48
101.44
101.33
101.26
101.16
101.13
101.01
100.88
100.90
100.86
100.75100.74
10
0
.
8
5
10
0
.
8
2
10
0
.
7
7
10
0
.
9
9
10
0
.
9
6
10
0
.
9
1
10
1
.
1
3
10
1
.
0
7
10
1
.
1
4
101.44
101.30
101.20
101.07
100.92
100.93
100.91
C/
L
LA
P
O
R
T
E
S
T
R
E
E
T
C/
L
A
L
L
E
Y
102.61
APN : 5773-004-015
APN : 5773-004-027
2-STORY BLDG
STORAGE
SHED
WAREHOUSE
1-STORY HOUSE
@ 103.15 FF
CALL TOLL FREE
1-800 227-2600
SERVICE ALERT
BEFORE YOU DIG
UNDERGROUND
TWO WORKING DAYS
ENGINEER'S NOTE TO CONTRACTOR:SOIL ENGINEER & PREPARED FORENGINEERING GEOLOGIST
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES,
CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS
DURING THE COURSE OF THE CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS
REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION
CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY, AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY LIABILITY, REAL
OR ALLEGED, IN CONNECTION OF THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF DESIGN PROFESSIONAL. THE EXISTENCE AND LOCATION OF OF ANY UNDERGROUND UTILITIES OR STRUCTURES
SHOWN IN THESE PLANS WERE OBTAINED FROM BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE
ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL
PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY
DAMAGE TO THESE LINES OR STRUCTURES.
DATEREVISIONS NO.
PROPOSED 1-STORY
PROJECT ADDRESS:
142 LA PORTE STREET, ARCADIA, CA 91006
PROJECT :
JOB NO.SHEET NAME:
UNDER THE SUPERVISION OF:
DATEGIL B. BERMEJO RCE 86264
MR. LEE CHAN & DON GABRIEL
CONTACT:
NAME:
ADDRESS:
TEL. NO.:
9428 ETON AVE. UNIT M, CHATSWORTH
818-341-1899
C.Y. GEOTECH, INC
CALIFORNIA 91311
JOB NO.: CYG-22-9538
CONTACT: PAUL CAI, P.E.
EMAIL: cygeotech@sbcglobal.net
DATED: JULY 8, 2022
Engineering Geology & Geotechnical Engineering
LA PORTE WAREHOUSE
No. 86264
IC I LV
G I L B E RM
E
J
O
Exp. 03-31-25
02/21/24
CLIENT/OWNER:
TEL. NO. : 415-531-0055
MR. LEE CHAN
CITY OF ARCADIA
DEVELOPMENT SERVICES DEPARTMENT
BUILDING DIVISION
Z-22-0370
7343 SANTA ELISE CIRCLE, BUENA PARK, CALIFORNIA 90620
ENGINEERING & SURVEYING, INC
TEL. NO. : 714-576-7725 EMAIL : info@zenithcels.com
ZENiTH
ARCHITECTURE ENGINEERING SURVEYING CONSTRUCTION
EMAIL : danielsdisplay@icloud.com
LOW IMPACT DEVELOPMENT
( IN FEET )
1 inch = ft.
GRAPHIC SCALE
0
8
84 16
CONSTRUCTION NOTES
C-4
PLAN & DETAILS
UNDISTURBED
BASE
4" TYP.
1 12" to 3" WASHED GRAVEL
BUILDING EDGE
SECTION
NOT TO SCALE
BU
I
L
D
I
N
G
/
F
O
U
N
D
A
T
I
O
N
E
D
G
E
PLAN
NOT TO SCALE
15
.
0
'
PER PLAN
PR
O
P
E
R
T
Y
L
I
N
E
PER PLAN PER PLAN
25' - 0" min.from bldg foundation
PER PLAN PER PLAN PER PLAN
2.0%
SLOPE
INFILTRATION TRENCH DETAIL
5.0' MIN.
FILTERPROVIDE
FABRIC
15.0'
PR
O
P
E
R
T
Y
L
I
N
E
A.C. PAVEMENT A.C. PAVEMENT
INFILTRATION TRENCH
INFILTRATION TRENCH
4" crushed aggregate base compacted
1.
5
'
M
I
N
.
25' - 0" min.from bldg foundation 10' - 0" min.from PL or
PERMEABLE LINER
INVERT PER
25' - 0" min.from bldg foundation
10' - 0" min.from PL
PLAN INVERT PERPLAN
TRENCH DRAIN
INVERT PERPLAN
GRATETRAFFIC TYPESLOPESLOPE
NOT TO SCALE
A1 = 4,096.00 SF
ROOF AREA
A2 = 2,894.00 SF
+ WALKWAY
PARKING AREA
2
1 3
3
4
INV-IN PER PLAN
3/4" GRAVEL
24'X24'x3.0'
PRETREATMENT BASIN
4" Ø PVC DRAIN PIPE
BYPASS DRAIN PIPE
TO APPROVE LOCATION
4" Ø PVC DRAIN PIPE
INV-OUT PER PLAN4" Ø PVC DRAIN PIPE
12
"
M
I
N
.
(with removable conc. cover)
(OVERFLOW)
CONC. PRE-FILTRATION BASIN
NTS
DRILL 1/8" WEEP HOLE TYP.
4 PLACES AT BOTTOM CORNERS
(BELOW PAVEMENT)
GRATE
4" Ø DRAIN PIPE
TRAFFIC TYPE
FILTERPROVIDE
FABRIC
FROM ROOF & AREA DRAINS
24"X24" C.B. WITHFILTER FABRIC
8" MIN.
8" MIN.
CLASS "D" 8" LOAD APPLICATION FOR CONCRETE / REBAR SUSPENSION METHOD.N. T. S.
TYPICAL DURASLOPE INSTALLATION
8" MIN.
EXISTING OR NEW CONCRETE
SLAB.
8"8"
EXISTING OR NEW CONCRETE
SLAB.
22"
TR
E
N
C
H
D
E
P
T
H
V
A
R
I
E
S
WI
T
H
S
L
O
P
E
O
F
D
R
A
I
N
.
MIN. SAW CUT.
1"
DS-200 FRAME
NOTE:
CALL TOLL FREE
1-800 227-2600
SERVICE ALERT
BEFORE YOU DIG
UNDERGROUND
TWO WORKING DAYS
ENGINEER'S NOTE TO CONTRACTOR:SOIL ENGINEER & PREPARED FORENGINEERING GEOLOGIST
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES,
CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS
DURING THE COURSE OF THE CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS
REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION
CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY, AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY LIABILITY, REAL
OR ALLEGED, IN CONNECTION OF THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF DESIGN PROFESSIONAL. THE EXISTENCE AND LOCATION OF OF ANY UNDERGROUND UTILITIES OR STRUCTURES
SHOWN IN THESE PLANS WERE OBTAINED FROM BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE
ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL
PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY
DAMAGE TO THESE LINES OR STRUCTURES.
DATEREVISIONS NO.
PROPOSED 1-STORY
PROJECT ADDRESS:
142 LA PORTE STREET, ARCADIA, CA 91006
PROJECT :
JOB NO.SHEET NAME:
UNDER THE SUPERVISION OF:
DATEGIL B. BERMEJO RCE 86264
MR. LEE CHAN & DON GABRIEL
CONTACT:
NAME:
ADDRESS:
TEL. NO.:
9428 ETON AVE. UNIT M, CHATSWORTH
818-341-1899
C.Y. GEOTECH, INC
CALIFORNIA 91311
JOB NO.: CYG-22-9538
CONTACT: PAUL CAI, P.E.
EMAIL: cygeotech@sbcglobal.net
DATED: JULY 8, 2022
Engineering Geology & Geotechnical Engineering
LA PORTE WAREHOUSE
No. 86264
IC I LV
G I L B E RM
E
J
O
Exp. 03-31-25
02/21/24
CLIENT/OWNER:
TEL. NO. : 415-531-0055
MR. LEE CHAN
CITY OF ARCADIA
DEVELOPMENT SERVICES DEPARTMENT
BUILDING DIVISION
Z-22-0370
7343 SANTA ELISE CIRCLE, BUENA PARK, CALIFORNIA 90620
ENGINEERING & SURVEYING, INC
TEL. NO. : 714-576-7725 EMAIL : info@zenithcels.com
ZENiTH
ARCHITECTURE ENGINEERING SURVEYING CONSTRUCTION
EMAIL : danielsdisplay@icloud.com
EROSION & SEDIMENT
CONTROL NOTES
EROSION AND SEDIMENT CONTROL PLAN (ESCP) GENERAL NOTES
1.IN CASE OF EMERGENCY, CALL ___________________________________ AT PHONE NO. _____________________
2.TOTAL DISTURBED ACRE _____________________________WDID # __________________________________
I. RISK LEVEL MORE THAN 1 ACRE 1 2 3 (CIRCLE ONE AS DETERMINED BY STATE GENERAL PERMIT FOR SITES GREATER THAN 1 ACRE
3.A STAND-BY CREW FOR EMERGENCY WORK SHALL BE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON (NOVEMBER 1 TO APRIL 15). NECESSARY MATERIALS SHALL BE
AVAILABLE ON-SITE AND STOCKPILED AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF EMERGENCY DEVICES WHEN RAIN IS IMMINENT.
4.EROSION CONTROL DEVICES SHOWN ON THIS PLAN MAY BE REMOVED WHEN APPROVED BY THE BUILDING OFFICIAL IF THE GRADING OPERATION HAS PROGRESSED TO THE POINT
WHERE THEY ARE NO LONGER REQUIRED.
5.GRADED AREAS ADJACENT TO FILL SLOPES LOCATED AT THE SITE PERIMETER MUST DRAIN AWAY FROM THE TOP OF SLOPE AT THE CONCLUSION OF EACH WORKING DAY. ALL
LOOSE SOILS AND DEBRIS THAT MAY CREATE A POTENTIAL HAZARD TO OFF-SITE PROPERTY SHALL BE STABILIZED OR REMOVED FROM THE SITE ON A DAILY BASIS.
6.ALL SILT AND DEBRIS SHALL BE REMOVED FROM ALL DEVICES WITHIN 24 HOURS AFTER EACH RAINSTORM AND BE DISPOSED OF PROPERLY.
7.A GUARD SHALL BE POSTED ON THE SITE WHENEVER THE DEPTH OF WATER IN ANY DEVICE EXCEEDS TWO FEET. THE DEVICE SHALL BE DRAINED OR PUMPED DRY WITHIN 24
HOURS AFTER EACH RAINSTORM. PUMPING AND DRAINING OF ALL BASINS AND DRAINAGE DEVICES MUST COMPLY MUST COMPLY WITH THE APPROPRIATE BMP FOR DEWATERING
OPERATIONS.
8.THE PLACEMENT OF ADDITIONAL DEVICES TO REDUCE EROSION DAMAGE AND CONTAIN POLLUTANTS WITHIN THE SITE IS LEFT TO THE DISCRETION OF THE FIELD ENGINEER.
ADDITIONAL DEVICES AS NEEDED SHALL BE INSTALLED TO RETAIN SEDIMENTS AND OTHER POLLUTANTS ON SITE.
9.DESILTING BASINS MAY NOT BE REMOVED OR MADE INOPERABLE BETWEEN NOVEMBER 1 AND APRIL 15 OF THE FOLLOWING YEAR WITHOUT THE APPROVAL OF THE BUILDING
OFFICIAL.
10.STORM WATER POLLUTION AND EROSION CONTROL DEVICES ARE TO BE MODIFIED, AS NEEDED, AS THE PROJECT PROGRESSES, THE DESIGN AND PLACEMENT OF THESE DEVICES IS
THE RESPONSIBILITY OF THE FIELD ENGINEER. PLANS REPRESENTING CHANGES MUST BE SUBMITTED FOR APPROVAL IF REQUESTED BY THE BUILDING OFFICIAL.
11.EVERY EFFORT SHOULD BE MADE TO ELIMINATE THE DISCHARGE OF NON-STORM WATER FROM THE PROJECT SITES AT ALL TIMES.
12.ERODED SEDIMENTS AND OTHER POLLUTANTS MUST BE RETAINED ON-SITE AND MAY NOT BE TRANSPORTED FROM THE SITE VIA SHEET FLOW, SWALES, AREA DRAINS, NATURAL
DRAINAGE COURSES, OR WIND.
13.STOCKPILES OF EARTH AND OTHER CONSTRUCTION-RELATED MATERIALS MUST BE PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY THE FORCES OF WIND OR WATER.
14.FUELS, OILS, SOLVENTS, AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE WITH THEIR LISTING AND ARE NOT TO CONTAMINATE THE SOILS AND SURFACE WATERS.
ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS
MAY NOT BE WASHED INTO THE DRAINAGE SYSTEM.
15.EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR ANY OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTES
ON-SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTE.
16.DEVELOPERS/CONTRACTORS ARE RESPONSIBLE TO INSPECT ALL EROSION CONTROL DEVICES AND BMPS ARE INSTALLED AND FUNCTIONING PROPERLY IF THERE IS A 50% OR
GREATER PROBABILITY OF PREDICTED PRECIPITATION, AND AFTER ACTUAL PRECIPITATION. A CONSTRUCTION SITE INSPECTION CHECKLIST AND INSPECTION LOG SHALL BE
MAINTAINED AT THE PROJECT SITE AT ALL TIMES AND AVAILABLE FOR REVIEW BY THE BUILDING OFFICIAL (COPIES OF THE SELF-INSPECTION CHECK LIST AND INSPECTION LOGS
ARE AVAILABLE UPON REQUEST).
17.TRASH AND CONSTRUCTION-RELATED SOLID WASTES MUST BE DEPOSITED INTO A COVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND DISPERSAL BY WIND.
18.SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE STABILIZED SO AS TO
INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC WAY. ACCIDENTAL DEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN OR
OTHER MEANS.
19.ANY SLOPES WITH DISTURBED SOILS OR DENUDED OF VEGETATION MUST BE STABILIZED SO AS TO INHIBIT EROSION BY WIND AND WATER.
20.AS THE ENGINEER/QSD OF RECORD, I HAVE SELECTED APPROPRIATE BMPS TO EFFECTIVELY MINIMIZE THE NEGATIVE IMPACTS OF THIS PROJECT’S CONSTRUCTION ACTIVITIES ON
STORM WATER QUALITY. THE PROJECT OWNER AND CONTRACTOR ARE AWARE THAT THE SELECTED BMPS MUST BE INSTALLED, MONITORED, AND MAINTAINED TO ENSURE THEIR
EFFECTIVENESS.
CIVIL ENGINEER SIGNATURE DATE
21.THE FOLLOWING NOTES MUST BE ON PLANS.
AS THE PROJECT OWNER OR AUTHORIZED AGENT OF THE OWNER, “I CERTIFY THAT THIS DOCUMENT AND ALL ATTACHMENTS WERE PREPARED UNDER MY DIRECTION OR
SUPERVISION IN ACCORDANCE WITH THE SYSTEM DESIGNED TO ENSURE THAT A QUALIFIED PERSONNEL PROPERLY GATHER AND EVALUATE THE INFORMATION SUBMITTED. BASED
ON MY INQUIRY OF THE PERSON OR PERSONS WHO MANAGE THE SYSTEM OR THOSE PERSONS DIRECTLY RESPONSIBLE FOR GATHERING THE INFORMATION, TO THE BEST OF MY
KNOWLEDGE AND BELIEF, THE INFORMATION SUBMITTED IS TRUE, ACCURATE, AND COMPLETE. I AM AWARE THAT SUBMITTING FALSE AND/ OR INACCURATE INFORMATION, FAILING
TO UPDATE THE ESCP TO REFLECT CURRENT CONDITIONS, OR FAILING TO PROPERLY AND/OR ADEQUATELY IMPLEMENT THE ESCP MAY RESULT IN REVOCATION OF GRADING
AND/OR OTHER PERMITS OR OTHER SANCTIONS PROVIDED BY LAW.”
OWNER OR AUTHORIZED REPRESENTATIVE(PERMITTEE)DATE
22.DEVELOPERS/CONTRACTORS ARE RESPONSIBLE TO INSPECT ALL EROSION CONTROL DEVICES AND BMPS ARE INSTALLED AND
FUNCTIONING PROPERLY AS REQUIRED BY THE STATE CONSTRUCTION GENERAL PERMIT. A CONSTRUCTION SITE INSPECTION CHECKLIST AND INSPECTION LOG SHALL BE
MAINTAINED AT THE PROJECT SITE AT ALL TIMES AND AVAILABLE FOR REVIEW BY THE BUILDING OFFICIAL.
THE FOLLOWING BMP'S AS OUTLINED IN, BUT NOT LIMITED TO, THE BEST MANAGEMENT PRACTICE
HANDBOOK, CALIFORNIA STORMWATER QUALITY TASK FORCE, SACRAMENTO, CALIFORNIA 2009, OR
THE LATEST REVISED EDITION, MAY APPLY DURING THE CONSTRUCTION OF THIS
PROJECT(ADDITIONAL MEASURES MAY BE REQUIRED IF DEEMED APPROPRIATE BY COUNTY
INSPECTORS.)
EROSION CONTROL
EC1 - SCHEDULING
EC2 - PRESERVATION OF EXISTING VEGETATION
EC3 - HYDRAULIC MULCH
EC4 - HYDROSEEDING
EC5 - SOIL BINDERS
EC6 - STRAW MULCH
EC7 - GEOTEXTILES AND MATS
EC8 - WOOD MULCHING
EC9 - EARTH DIKES AND DRAINAGE SWALES
EC10 - VELOCITY DISSIPATION DEVICE
EC11 - SLOPE DRAINS
EC12 - STREAMBANK STABILIZATION
EC13 - POLYACRYLAMIDE
TEMPORARY SEDIMENTS CONTROL
SE1 - SILT FENCE
SE2 - SEDIMENT BASIN
SE3 - SEDIMENT TRAP
SE4 - CHECK DAM
SE5 - FIBER ROLLS
SE6 - GRAVEL BAG BERM
SE7 - STREET SWEEPING AND VACCUMING
SE8 - GRAVEL BAG BARRIER
SE9 - STORM DRAIN INLET PROTECTION
WIND EROTION CONTROL
WE1 - WIND EROSION CONTROL
EQUIPMENT TRACKING CONTROL
TC1 - STABILIZED CONSTRUCTION ENTRANCE
TC2 - STABILIZED CONSTRUCTION ROADWAY
TC3 - ENTRANCE/OUTLET TIRE TRASH
NON-STORMWATER MANAGEMENT
NS1 - WATER CONSTRUCTION PRACTICE
NS2 - DEWATERING OPERATIONS
NS3 - PAVING AND GRINDING OPERATIONS
NS4 - TEMPORARY STREAM CROSSING
NS5 - CLEAR WATER DIVERSION
NS6 - ILLICIT CONNECTION/DISCHARGE
NS7 - POTABLE WATER/ IRRIGATION
NS8 - VEHICLE AND EQUIPMENT CLEANING
NS9 - VEHICLE AND EQUIPMENT FUELING
NS10 - VEHICLE AND EQUIPMENT MAINTENANCE
NS11 - PILE DRIVING OPERATIONS
NS12 - CONCRETE CURING
NS13 - CONCRETE FINISHING
NS14 - MATERIAL AND EQUIPMENT USE
NS15 - DEMOLISION ADJACET TO WATER
NS16 - TEMPORARY BATCH PLANTS
WASTE MANAGEMENT AND MATERIAL POLLUTION CONTROL
WM1 - MATERIAL DELIVERY AND STORAGE
WM2 - MATERIAL USE
WM3 - STOCKPILE MANAGEMENT
WM4 - SPILL PRESERVATION AND CONTROL
WM5 - SOLID WASTE MANAGEMENT
WM6 - HAZARDOUS WASTE MANAGEMENT
WM7 - CONTAMINATION SOIL MANAGEMENT
WM8 - CONCRETE WASTE MANAGEMENT
WM9 - SANITARY/SEPTIC WASTE MANAGEMENT
WM10 - LIQUID WASTE MANAGEMENT
GIL B. BERMEJO
0.18 AC
GIL B. BERMEJO 714-576-7725
BEST MANAGEMENT PRACTICE NOTES
1. EVERY EFFORT SHOULD BE MADE TO ELIMINATE THE DISCHARGE OF NON-STORMWATER FROM THE PROJECT SITE AT ALL TIMES.
2. ERODED SEDIMENTS AND OTHER POLLUTANTS MUST BE RETAINED ON-SITE AND MAY NOT BE TRANSPORTED FROM THE SITE VIA
SHEET FLOW, SWALES, AREA DRAINS, NATURAL DRAINAGE COURSES OR WIND.
3. STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED MATERIALS MUST BE PROTECTED FROM BEING TRANSPORTED
FROM THE SITE BY THE FORCES OF WIND OR WATER.
4. FUELS, OILS, SOLVENTS, AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE WITH THEIR LISTING AND ARE NOT TO
CONTAMINATE THE SOIL AND SURFACE WATERS. ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED FROM THE
WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED
INTO THE DRAINAGE SYSTEM.
5. EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR ANY OTHER DRAINAGE SYSTEM. PROVISIONS
SHALL BE MADE TO RETAIN CONCRETE WASTES ON-SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTE.
6. TRASH AND CONSTRUCTION RELATED SOLID WASTES MUST BE DEPOSITED INTO A COVERED RECEPTACLE TO PREVENT
CONTAMINATION OF RAINWATER AND DISPERSAL BY WIND.
7. SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE
ROADWAYS MUST BE STABILIZED SO AS TO INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC WAY. ACCIDENTAL
DEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN OR OTHER MEANS.
8. ANY SLOPES WITH DISTURBED SOILS OR DENUDED OF VEGETATION MUST BE STABILIZED SO AS TO INHIBIT EROSION BY WIND
AND WATER.
9. “I CERTIFY THAT THIS DOCUMENT AND ALL ATTACHMENTS WERE PREPARED UNDER MY DIRECTION OR SUPERVISION IN
ACCORDANCE WITH A SYSTEM DESIGNED TO ENSURE THAT QUALIFIED PERSONNEL PROPERLY GATHER AND EVALUATE THE
INFORMATION SUBMITTED. BASED ON MY INQUIRY OF THE PERSON OR PERSONS WHO MANAGE THE SYSTEM OR THOSE
PERSONS DIRECTLY RESPONSIBLE FOR GATHERING THE INFORMATION, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THE
INFORMATION SUBMITTED IS TRUE, ACCURATE, AND COMPLETE. I AM AWARE THAT SUBMITTING FALSE AND/ OR INACCURATE
INFORMATION, FAILING TO UPDATE THE ESCP TO REFLECT CURRENT CONDITIONS, OR FAILING TO PROPERLY AND/ OR
ADEQUATELY IMPLEMENT THE ESCP MAY RESULT IN REVOCATION OF GRADING AND/ OR OTHER PERMITS OR OTHER SANCTIONS
PROVIDED BY LAW.”
PRINT NAME _____________________________________________
(OWNER OR AUTHORIZED AGENT OF THE OWNER)
SIGNATURE ______________________________________________ DATE __________________
(OWNER OR AUTHORIZED AGENT OF THE OWNER)
THE FOLLOWING BMPS AS OUTLINED IN, BUT NOT LIMITED TO, THE LATEST EDITION OF THE CASQA CONSTRUCTION BMP ONLINE
HANDBOOK OR CALTRANS STORMWATER QUALITY HANDBOOKS (CONSTRUCTION SITE BMP MANUAL), MAY APPLY DURING THE
CONSTRUCTION OF THIS PROJECT (ADDITIONAL MEASURES MAY BE REQUIRED IF DEEMED APPROPRIATE BY THE PROJECT
ENGINEER OR THE BUILDING OFFICIAL)
N/A
MR. LEE CHAN
MR. LEE CHAN
ESCP-1
01/28/2023
118.72
ROOF ELEV.
117.31
ROOF ELEV.
48"Ø TREE
24"Ø TREE
18"Ø TREE
12"Ø TREE
102.26 TC
101.78FL
102.34TOP "X"
101.90FL
101.72BOT "X"
101.80BOT "X"
102.37 TOP "X"
101.93FL
102.46TC
101.95FL
102.58 TC
102.07FL
102.71TC
102.28FL
102.92
102.56102.57
102.49 102.54
102.48
102.32
102.30102.43
102.44
102.14
102.21
102.47
102.65
102.87
102.76
102.68102.74
102.67 102.70
102.54TC 102.68TC
102.19
102.30
102.37
102.40
102.08
102.20
102.49 102.56 103.60
104.34
104.30
104.53FF
104.27
103.41
102.48
102.81
102.77
102.63
102.45
102.59 102.50
102.68102.72
102.69
102.74
102.63
102.04
105.64TW105.86 TW
18"Ø TREE
36"Ø TREE
124.77
103.03
102.96
102.87
102.83102.90
102.76
102.59 102.43
102.51102.61
102.66
102.81
103.03103.18
102.73
102.75
102.68102.73
104.24
102.72
107.15TW
107.15TW
105.81TW
105.73TW 108.44TW
101.31
104.04
102.23
102.22 104.15
104.48FF
102.22
102.17
102.17102.04101.88101.82101.61
101.63101.46101.40101.30101.34
101.37
101.49
101.40
101.36 101.38
101.38 101.50
101.68
101.86
101.95
101.94
102.02
102.04
101.91
102.09
102.22
102.28 102.37
102.26
102.27
102.17
102.04
101.53
101.40
101.52
101.58
101.88
102.04
102.12
102.22
101.32
101.35
101.32101.47101.34
101.48 101.39
101.33
101.34101.38
101.95
101.94102.10FF
101.36
101.48
101.49
101.34
101.41
101.42101.23101.07
101.08
107.26TW 101.28
101.20
101.10
100.91
101.26101.27
101.33101.17
101.43
101.32 101.48
101.44
101.33
101.26
101.16
101.13
101.01
100.88
100.90
100.86
100.75100.74
10
0
.
8
5
10
0
.
8
2
10
0
.
7
7
10
0
.
9
9
10
0
.
9
6
10
0
.
9
1
10
1
.
1
3
10
1
.
0
7
10
1
.
1
4
101.44
101.30
101.20
101.07
100.92
100.93
100.91
100.83
C/
L
LA
P
O
R
T
E
S
T
R
E
E
T
C/
L
A
L
L
E
Y
102.61
APN : 5773-004-015
APN : 5773-004-027
2-STORY BLDG
STORAGE
SHED
APN : 5773-004-014
1-STORY HOUSE
WAREHOUSE
1-STORY HOUSE
@ 103.15 FF
CALL TOLL FREE
1-800 227-2600
SERVICE ALERT
BEFORE YOU DIG
UNDERGROUND
TWO WORKING DAYS
ENGINEER'S NOTE TO CONTRACTOR:SOIL ENGINEER & PREPARED FORENGINEERING GEOLOGIST
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES,
CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS
DURING THE COURSE OF THE CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS
REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION
CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY, AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY LIABILITY, REAL
OR ALLEGED, IN CONNECTION OF THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF DESIGN PROFESSIONAL. THE EXISTENCE AND LOCATION OF OF ANY UNDERGROUND UTILITIES OR STRUCTURES
SHOWN IN THESE PLANS WERE OBTAINED FROM BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE
ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL
PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY
DAMAGE TO THESE LINES OR STRUCTURES.
DATEREVISIONS NO.
PROPOSED 1-STORY
PROJECT ADDRESS:
142 LA PORTE STREET, ARCADIA, CA 91006
PROJECT :
JOB NO.SHEET NAME:
UNDER THE SUPERVISION OF:
DATEGIL B. BERMEJO RCE 86264
MR. LEE CHAN & DON GABRIEL
CONTACT:
NAME:
ADDRESS:
TEL. NO.:
9428 ETON AVE. UNIT M, CHATSWORTH
818-341-1899
C.Y. GEOTECH, INC
CALIFORNIA 91311
JOB NO.: CYG-22-9538
CONTACT: PAUL CAI, P.E.
EMAIL: cygeotech@sbcglobal.net
DATED: JULY 8, 2022
Engineering Geology & Geotechnical Engineering
LA PORTE WAREHOUSE
No. 86264
IC I LV
G I L B E RM
E
J
O
Exp. 03-31-25
02/21/24
CLIENT/OWNER:
TEL. NO. : 415-531-0055
MR. LEE CHAN
CITY OF ARCADIA
DEVELOPMENT SERVICES DEPARTMENT
BUILDING DIVISION
Z-22-0370
7343 SANTA ELISE CIRCLE, BUENA PARK, CALIFORNIA 90620
ENGINEERING & SURVEYING, INC
TEL. NO. : 714-576-7725 EMAIL : info@zenithcels.com
ZENiTH
ARCHITECTURE ENGINEERING SURVEYING CONSTRUCTION
EMAIL : danielsdisplay@icloud.com
EROSION & SEDIMENT
CONTROL PLAN
2
1
BMP CONSTRUCTION NOTES:
4
3
PLACE SAND BAGS TWO ROWS HIGH PER CASQA BMP # SE-8 (SEE DETAIL ON SHEET ESCP-5).
PROVIDE BERMED CONCRETE AND MORTAR WASHOUT CONTAINMENT AREA PER CASQA BMP # WM-8 (SEE DETAIL ON SHEET ESCP-4).
PROTECT STOCKPILED MATERIALS FROM EROSION PER CASQA BMP # WM-3 (SEE DETAIL ON SHEET ESCP-4).
INSTALL STABILIZED CONSTRUCTION ENTRANCE PER CASQA BMP # TC-1 (SEE DETAIL ON SHEET ESCP-3).
5
6 PROVIDE STREET SWEEPING AND VACUUMING PER CASQA BMP # SE-7 (SEE DETAIL ON ESCP-6).
PLACE TEMPORARY SANITARY/SEPTIC WASTE MANAGEMENT PER CASQA BMP # WM-9 (SEE DETAIL ON ESCP-6).
3
2
4
6
ESCP-2
1
44
4
4
4
5
6
CALL TOLL FREE
1-800 227-2600
SERVICE ALERT
BEFORE YOU DIG
UNDERGROUND
TWO WORKING DAYS
ENGINEER'S NOTE TO CONTRACTOR:SOIL ENGINEER & PREPARED FORENGINEERING GEOLOGIST
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES,
CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS
DURING THE COURSE OF THE CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS
REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION
CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY, AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY LIABILITY, REAL
OR ALLEGED, IN CONNECTION OF THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF DESIGN PROFESSIONAL. THE EXISTENCE AND LOCATION OF OF ANY UNDERGROUND UTILITIES OR STRUCTURES
SHOWN IN THESE PLANS WERE OBTAINED FROM BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE
ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL
PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY
DAMAGE TO THESE LINES OR STRUCTURES.
DATEREVISIONS NO.
PROPOSED 1-STORY
PROJECT ADDRESS:
142 LA PORTE STREET, ARCADIA, CA 91006
PROJECT :
JOB NO.SHEET NAME:
UNDER THE SUPERVISION OF:
DATEGIL B. BERMEJO RCE 86264
MR. LEE CHAN & DON GABRIEL
CONTACT:
NAME:
ADDRESS:
TEL. NO.:
9428 ETON AVE. UNIT M, CHATSWORTH
818-341-1899
C.Y. GEOTECH, INC
CALIFORNIA 91311
JOB NO.: CYG-22-9538
CONTACT: PAUL CAI, P.E.
EMAIL: cygeotech@sbcglobal.net
DATED: JULY 8, 2022
Engineering Geology & Geotechnical Engineering
LA PORTE WAREHOUSE
No. 86264
IC I LV
G I L B E RM
E
J
O
Exp. 03-31-25
02/21/24
CLIENT/OWNER:
TEL. NO. : 415-531-0055
MR. LEE CHAN
CITY OF ARCADIA
DEVELOPMENT SERVICES DEPARTMENT
BUILDING DIVISION
Z-22-0370
7343 SANTA ELISE CIRCLE, BUENA PARK, CALIFORNIA 90620
ENGINEERING & SURVEYING, INC
TEL. NO. : 714-576-7725 EMAIL : info@zenithcels.com
ZENiTH
ARCHITECTURE ENGINEERING SURVEYING CONSTRUCTION
EMAIL : danielsdisplay@icloud.com
(CASQA BMP # TC-1 )
EROSION & SEDIMENT
CONTROL DETAILS
ESCP-3
CALL TOLL FREE
1-800 227-2600
SERVICE ALERT
BEFORE YOU DIG
UNDERGROUND
TWO WORKING DAYS
ENGINEER'S NOTE TO CONTRACTOR:SOIL ENGINEER & PREPARED FORENGINEERING GEOLOGIST
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES,
CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS
DURING THE COURSE OF THE CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS
REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION
CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY, AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY LIABILITY, REAL
OR ALLEGED, IN CONNECTION OF THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF DESIGN PROFESSIONAL. THE EXISTENCE AND LOCATION OF OF ANY UNDERGROUND UTILITIES OR STRUCTURES
SHOWN IN THESE PLANS WERE OBTAINED FROM BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE
ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL
PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY
DAMAGE TO THESE LINES OR STRUCTURES.
DATEREVISIONS NO.
PROPOSED 1-STORY
PROJECT ADDRESS:
142 LA PORTE STREET, ARCADIA, CA 91006
PROJECT :
JOB NO.SHEET NAME:
UNDER THE SUPERVISION OF:
DATEGIL B. BERMEJO RCE 86264
MR. LEE CHAN & DON GABRIEL
CONTACT:
NAME:
ADDRESS:
TEL. NO.:
9428 ETON AVE. UNIT M, CHATSWORTH
818-341-1899
C.Y. GEOTECH, INC
CALIFORNIA 91311
JOB NO.: CYG-22-9538
CONTACT: PAUL CAI, P.E.
EMAIL: cygeotech@sbcglobal.net
DATED: JULY 8, 2022
Engineering Geology & Geotechnical Engineering
LA PORTE WAREHOUSE
No. 86264
IC I LV
G I L B E RM
E
J
O
Exp. 03-31-25
02/21/24
CLIENT/OWNER:
TEL. NO. : 415-531-0055
MR. LEE CHAN
CITY OF ARCADIA
DEVELOPMENT SERVICES DEPARTMENT
BUILDING DIVISION
Z-22-0370
7343 SANTA ELISE CIRCLE, BUENA PARK, CALIFORNIA 90620
ENGINEERING & SURVEYING, INC
TEL. NO. : 714-576-7725 EMAIL : info@zenithcels.com
ZENiTH
ARCHITECTURE ENGINEERING SURVEYING CONSTRUCTION
EMAIL : danielsdisplay@icloud.com
(CASQABMP # WM-8)
EROSION & SEDIMENT
CONTROL DETAILS
ESCP-4
CALL TOLL FREE
1-800 227-2600
SERVICE ALERT
BEFORE YOU DIG
UNDERGROUND
TWO WORKING DAYS
ENGINEER'S NOTE TO CONTRACTOR:SOIL ENGINEER & PREPARED FORENGINEERING GEOLOGIST
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES,
CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS
DURING THE COURSE OF THE CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS
REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION
CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY, AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY LIABILITY, REAL
OR ALLEGED, IN CONNECTION OF THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF DESIGN PROFESSIONAL. THE EXISTENCE AND LOCATION OF OF ANY UNDERGROUND UTILITIES OR STRUCTURES
SHOWN IN THESE PLANS WERE OBTAINED FROM BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE
ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL
PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY
DAMAGE TO THESE LINES OR STRUCTURES.
DATEREVISIONS NO.
PROPOSED 1-STORY
PROJECT ADDRESS:
142 LA PORTE STREET, ARCADIA, CA 91006
PROJECT :
JOB NO.SHEET NAME:
UNDER THE SUPERVISION OF:
DATEGIL B. BERMEJO RCE 86264
MR. LEE CHAN & DON GABRIEL
CONTACT:
NAME:
ADDRESS:
TEL. NO.:
9428 ETON AVE. UNIT M, CHATSWORTH
818-341-1899
C.Y. GEOTECH, INC
CALIFORNIA 91311
JOB NO.: CYG-22-9538
CONTACT: PAUL CAI, P.E.
EMAIL: cygeotech@sbcglobal.net
DATED: JULY 8, 2022
Engineering Geology & Geotechnical Engineering
LA PORTE WAREHOUSE
No. 86264
IC I LV
G I L B E RM
E
J
O
Exp. 03-31-25
02/21/24
CLIENT/OWNER:
TEL. NO. : 415-531-0055
MR. LEE CHAN
CITY OF ARCADIA
DEVELOPMENT SERVICES DEPARTMENT
BUILDING DIVISION
Z-22-0370
7343 SANTA ELISE CIRCLE, BUENA PARK, CALIFORNIA 90620
ENGINEERING & SURVEYING, INC
TEL. NO. : 714-576-7725 EMAIL : info@zenithcels.com
ZENiTH
ARCHITECTURE ENGINEERING SURVEYING CONSTRUCTION
EMAIL : danielsdisplay@icloud.com
(CASQABMP # WM-3 & SE-8)
EROSION & SEDIMENT
CONTROL DETAILS
ESCP-5
CALL TOLL FREE
1-800 227-2600
SERVICE ALERT
BEFORE YOU DIG
UNDERGROUND
TWO WORKING DAYS
ENGINEER'S NOTE TO CONTRACTOR:SOIL ENGINEER & PREPARED FORENGINEERING GEOLOGIST
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES,
CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS
DURING THE COURSE OF THE CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS
REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION
CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY, AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY LIABILITY, REAL
OR ALLEGED, IN CONNECTION OF THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF DESIGN PROFESSIONAL. THE EXISTENCE AND LOCATION OF OF ANY UNDERGROUND UTILITIES OR STRUCTURES
SHOWN IN THESE PLANS WERE OBTAINED FROM BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE
ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL
PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY
DAMAGE TO THESE LINES OR STRUCTURES.
DATEREVISIONS NO.
PROPOSED 1-STORY
PROJECT ADDRESS:
142 LA PORTE STREET, ARCADIA, CA 91006
PROJECT :
JOB NO.SHEET NAME:
UNDER THE SUPERVISION OF:
DATEGIL B. BERMEJO RCE 86264
MR. LEE CHAN & DON GABRIEL
CONTACT:
NAME:
ADDRESS:
TEL. NO.:
9428 ETON AVE. UNIT M, CHATSWORTH
818-341-1899
C.Y. GEOTECH, INC
CALIFORNIA 91311
JOB NO.: CYG-22-9538
CONTACT: PAUL CAI, P.E.
EMAIL: cygeotech@sbcglobal.net
DATED: JULY 8, 2022
Engineering Geology & Geotechnical Engineering
LA PORTE WAREHOUSE
No. 86264
IC I LV
G I L B E RM
E
J
O
Exp. 03-31-25
02/21/24
CLIENT/OWNER:
TEL. NO. : 415-531-0055
MR. LEE CHAN
CITY OF ARCADIA
DEVELOPMENT SERVICES DEPARTMENT
BUILDING DIVISION
Z-22-0370
7343 SANTA ELISE CIRCLE, BUENA PARK, CALIFORNIA 90620
ENGINEERING & SURVEYING, INC
TEL. NO. : 714-576-7725 EMAIL : info@zenithcels.com
ZENiTH
ARCHITECTURE ENGINEERING SURVEYING CONSTRUCTION
EMAIL : danielsdisplay@icloud.com
(CASQABMP # WM-9)
EROSION & SEDIMENT
CONTROL DETAILS
ESCP-6