HomeMy WebLinkAbout150 N Santa Anita Ave - 2024 - INSTALL 208 LF OF 8'' PVC SDR 35 SEWER LINE WITH 6 CLEANOUTS.G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G J N. S A N T A A N I T A A V E WHEELER AVE E SANTA CLARA ST ALLEY NOT A PART AL L E Y LOT 1 LOT 2 8" - 33.8 LF @ 1.98% 8" - 29.4 LF @ 1.98% 487.00 8" INV 481.28 8" INV 479.38 8" INV 8" - 78.2 LF @ 7.31% 6" - 2.4 LF @ 1.70% 40 41 33 31 31 R/W PL 32 480.09 6" INV 33 31 33 34 477.97 8" INV34 EXISTING SEWER MAIN LINE OF BUILDING BELOW 42 NEW 8" WATERMAIN PER SEPARATE PUBLIC IMPROVEMENT PLANS & PERMIT SEE NOTE D NEW SEWER MANHOLE PER SEPARATE PUBLIC IMPROVEMENT PLAN & PERMIT SEE NOTE C SEE NOTE C SEE NOTE D SEE NOTE B SEE NOTE B 480.05 6" INV 478.71 8" INV 33 32 SEE NOTE D EXISTING SEWER FROM BUILDING EXISTING SEWER FROM BUILDING 34 481.92 8" INV 477.16 8" INV SEE NOTE D 8" - 36.5 LF @ 1.98% 33 8" - 30.2 LF @ 1.98% 31 31 31 V: \ 1 A R C 0 4 0 1 0 0 \ E N G R \ S H E E T S \ C 4 . 0 0 U t i l i t i e s . d w g 3/ 1 5 / 2 0 2 4 2 : 4 6 P M 57 9 0 F L E E T S T R E E T , S U I T E 1 4 0 CA R L S B A D , C A 9 2 0 0 8 ISSUANCE NAME DATE AL E X A N A R C A D I A MI X E D - U S E / M U L T I - F A M I L Y H O U S I N G PR O J E C T 27 2 2 0 T U R N B E R R Y L A N E , SU I T E 1 9 0 VA L E N C I A , C A 9 1 3 5 5 66 1 . 2 1 9 . 6 0 0 0 50% DD 11/07/22 34 E . S A N T A C L A R A S T . AR C A D I A , C A 9 1 0 0 6 100% DD 12/19/22 50% CD 02/13/23 PC SUBMITTAL 04/24/236 5 PC SUBMITTAL 2 08/07/237 VOLUME 03 PC SUBMITTAL 3 12/11/238 PC SUBMITTAL 4 02/12/249 PC SUBMITTAL 5 03/15/2410 C4.00 UTILITY PLAN CONSTRUCTION NOTES SANITARY SEWER EXTEND EXISTING 8" VCP HOUSE CONNECTION TO NEW R/W. CONTRACTOR TO FIELD VERIFY LOCATION AND INVERT. INSTALL PVC SDR35 SEWER. SIZE, LENGTH AND SLOPE PER PLAN INTERCEPT EXISTING SEWER AND CONNECT TO NEW LINE. CONTRACTOR TO FIELD VERIFY LOCATION AND INVERT OF EXISTING SEWER INSTALL CLEANOUT STRUCTURE PER DETAIL 2 SHEET C7.20 POINT OF CONNECTION FOR BUILDING. REFER TO PLUMBING PLAN FOR CONTINUATION WATER SUPPLY WATER LINE TO BUILDING POINT OF CONNECTION. BACKFLOW PREVENTOR ASSEMBLY LOCATED OUTSIDE THE BUILDING. PROVIDE APPROVED RP PREVENTOR ( ZURN 475V RPP OR EQUAL) PER CITY STD.712 REFER SHEET C7.20. REFER TO PLUMBING PLANS FOR CONTINUATION. FIRE LINE TO BUILDING POINT OF CONNECTION. DETECTOR CHECK ASSEMBLY LOCATED OUTSIDE THE BUILDING. PROVIDE APPROVED DETECTOR CHECK (WATTS DERINGER 30G OR EQUAL) PER CITY STD. 714 REFER SHEET C7.20. FIRE RISERS 8" AMES, SS, AWWA C900 INLET/DIP AND AWWA C606 OUTLET PER DETAIL 9 ON SHEET C6.01. REFER TO PLUMBING PLANS FOR CONTINUATION IRRIGATION LINE TO BUILDING POINT OF CONNECTION WITH RP BACFLOW DEVICE PER CITY STD. 712. REFER TO IRRIGATION PLANS FOR DETAILS NOTES A.TRENCH AND BEDDING DETAIL PER CITY OF ARCADIA STD PLAN 702 B.WATER SERVICE CONNECTIONS TO SITE PER SEPARATE PUBLIC IMPROVEMENT PLANS & PERMIT C.FIRE HYDRANT ASSEMBLY PER SEPARATE PUBLIC WORK IMPROVEMENT PLAN & PERMIT D.SEWER HOUSE CONNECTION TO SITE PER SEPARATE PUBLIC IMPROVEMENT PLANS & PERMIT 30 31 32 33 34 40 41 42 LEGEND WATER LINE FIRE WATER LINE SANITARY SEWER CLEANOUT STRUCTURE GATE VALVE FIRE HYDRANT THRUST BLOCK DRY UTILITY TRENCH (REFER TO DRY UTILITY PLANS BY RGI) 3/15/24 CITY OF ARCADIA DEVELOPMENT SERVICES DIVISION APPROVED By Subject to field inspection approval. The stamping of this plan and specifications SHALL NOT be held to permit or to be an approval of the violation of any provisions of any City Ordinance, State Law or Recognized Standard __________________________K. Fields 03/20/2024 SEWER ONLY V: \ 1 A R C 0 4 0 1 0 0 \ E N G R \ S H E E T S \ C 7 . 0 0 D e t a i l s . d w g 3/ 1 9 / 2 0 2 4 3 : 4 0 P M 57 9 0 F L E E T S T R E E T , S U I T E 1 4 0 CA R L S B A D , C A 9 2 0 0 8 ISSUANCE NAME DATE AL E X A N A R C A D I A MI X E D - U S E / M U L T I - F A M I L Y H O U S I N G PR O J E C T 27 2 2 0 T U R N B E R R Y L A N E , SU I T E 1 9 0 VA L E N C I A , C A 9 1 3 5 5 66 1 . 2 1 9 . 6 0 0 0 50% DD 11/07/22 34 E . S A N T A C L A R A S T . AR C A D I A , C A 9 1 0 0 6 100% DD 12/19/22 50% CD 02/13/23 PC SUBMITTAL 04/24/236 5 PC SUBMITTAL 2 08/07/237 VOLUME 03 PC SUBMITTAL 3 12/11/238 PC SUBMITTAL 4 02/12/249 PC SUBMITTAL 5 03/15/2410 NTS CLEANOUT STURCTURE2 C7.20 UTILITY DETAILS BE SQUARE OR CONC. COLLAR MAY MI N . MI N . GR A N U L A R M A T E R I A L I N L I E U O F RE L A T I V E C O M P A C T I O N W I T H 1 / 2 " CO N T R A C T O R M A Y R E C O M P A C T CL E A N - O U T E X C A V A T I O N T O M I N . 9 0 % CO N C R E T E B A S E A N D P I P E S U P P O R T FO R N O N T R A F F I C A R E A S TRAFFIC LOAD WYE UNDISTURBED EARTH PIPE 4" MIN. 1/8 BEND CONDITION MAIN SECTION A-A 2-3/16" MI N . 13 " B 2" MIN. 4" MIN. 2" M I N . B 13 " MI N . 12 " CLEANOUT FRAME & COVER PER ALHAMBRA FOUNDRY CO. PRODUCT NO. A-1240 FOR 6" RISER OR A-1241 FOR SECTION B-B OPTIONAL CONSTRUCTION CONC. BASE SUPPORT FOR 8" RISER OR APPROVED EQUAL AND WALL RISER JOINT MI N . 6" 4" 12" MIN. 9" MIN. 9" MIN. 12" MIN. CONCRETE BASE AND WALL SUPPORT FOR TRAFFIC LOAD CONDITIONS 18" MIN. 13 " MI N . CIRCULAR 26 " MI N . 24 " M I N . 12 " INVERT ELEV. PER PLAN INSTALL CAP & SEAL IF TERMINAL CLEANOUT. INSTALL PIPE IF IN-LINE CLEANOUT. RISER SHALL BE THE SAME AS MAIN PIPE DIAMETER DIAMETER AND MATERIAL OF FOR 6" WITH 3/4" DIA FINGER HOLE IN CENTER FINISHED SURFACE ELEV. PER PLAN TOP OF CLEAN-OUT COVER FRAME PLAN A A NTS 6" COMPOUND METER1 NTS THRUST AND ANCHOR BLOCKS 4 NTS SEWER MANHOLE ADJUSTMENT5 NTS TRENCH DETAIL3 3/19/24 CITY OF ARCADIA DEVELOPMENT SERVICES DIVISION APPROVED By Subject to field inspection approval. The stamping of this plan and specifications SHALL NOT be held to permit or to be an approval of the violation of any provisions of any City Ordinance, State Law or Recognized Standard __________________________K. Fields 03/20/2024