HomeMy WebLinkAbout150 N Santa Anita Ave - 2024 - INSTALL 208 LF OF 8'' PVC SDR 35 SEWER LINE WITH 6 CLEANOUTS.G G
G
G
G
G
G
G
G
G
G
G
G
G
G
G G G G G G
G G G G G G G
G
G G G G G G G
J
N.
S
A
N
T
A
A
N
I
T
A
A
V
E
WHEELER AVE
E SANTA CLARA ST
ALLEY
NOT A PART
AL
L
E
Y
LOT 1
LOT 2
8" - 33.8 LF
@ 1.98%
8" - 29.4 LF
@ 1.98%
487.00
8" INV
481.28
8" INV
479.38
8" INV
8" - 78.2 LF
@ 7.31%
6" - 2.4 LF
@ 1.70%
40
41
33
31
31
R/W
PL
32 480.09
6" INV
33
31
33
34
477.97
8" INV34
EXISTING
SEWER MAIN
LINE OF BUILDING BELOW
42
NEW 8" WATERMAIN
PER SEPARATE PUBLIC
IMPROVEMENT PLANS &
PERMIT
SEE NOTE D
NEW SEWER MANHOLE PER
SEPARATE PUBLIC
IMPROVEMENT PLAN & PERMIT
SEE NOTE C
SEE NOTE C
SEE NOTE D
SEE NOTE B
SEE NOTE B
480.05
6" INV
478.71
8" INV
33
32
SEE NOTE D
EXISTING SEWER
FROM BUILDING
EXISTING SEWER
FROM BUILDING
34
481.92
8" INV
477.16
8" INV
SEE NOTE D
8" - 36.5 LF
@ 1.98%
33
8" - 30.2 LF
@ 1.98%
31
31
31
V:
\
1
A
R
C
0
4
0
1
0
0
\
E
N
G
R
\
S
H
E
E
T
S
\
C
4
.
0
0
U
t
i
l
i
t
i
e
s
.
d
w
g
3/
1
5
/
2
0
2
4
2
:
4
6
P
M
57
9
0
F
L
E
E
T
S
T
R
E
E
T
,
S
U
I
T
E
1
4
0
CA
R
L
S
B
A
D
,
C
A
9
2
0
0
8
ISSUANCE NAME DATE
AL
E
X
A
N
A
R
C
A
D
I
A
MI
X
E
D
-
U
S
E
/
M
U
L
T
I
-
F
A
M
I
L
Y
H
O
U
S
I
N
G
PR
O
J
E
C
T
27
2
2
0
T
U
R
N
B
E
R
R
Y
L
A
N
E
,
SU
I
T
E
1
9
0
VA
L
E
N
C
I
A
,
C
A
9
1
3
5
5
66
1
.
2
1
9
.
6
0
0
0
50% DD 11/07/22
34
E
.
S
A
N
T
A
C
L
A
R
A
S
T
.
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
100% DD 12/19/22
50% CD 02/13/23
PC SUBMITTAL 04/24/236
5
PC SUBMITTAL 2 08/07/237
VOLUME 03
PC SUBMITTAL 3 12/11/238
PC SUBMITTAL 4 02/12/249
PC SUBMITTAL 5 03/15/2410
C4.00
UTILITY PLAN
CONSTRUCTION NOTES
SANITARY SEWER
EXTEND EXISTING 8" VCP HOUSE CONNECTION TO NEW R/W. CONTRACTOR TO FIELD VERIFY LOCATION
AND INVERT.
INSTALL PVC SDR35 SEWER. SIZE, LENGTH AND SLOPE PER PLAN
INTERCEPT EXISTING SEWER AND CONNECT TO NEW LINE. CONTRACTOR TO FIELD VERIFY LOCATION
AND INVERT OF EXISTING SEWER
INSTALL CLEANOUT STRUCTURE PER DETAIL 2 SHEET C7.20
POINT OF CONNECTION FOR BUILDING. REFER TO PLUMBING PLAN FOR CONTINUATION
WATER SUPPLY
WATER LINE TO BUILDING POINT OF CONNECTION. BACKFLOW PREVENTOR ASSEMBLY LOCATED
OUTSIDE THE BUILDING. PROVIDE APPROVED RP PREVENTOR ( ZURN 475V RPP OR EQUAL) PER CITY
STD.712 REFER SHEET C7.20. REFER TO PLUMBING PLANS FOR CONTINUATION.
FIRE LINE TO BUILDING POINT OF CONNECTION. DETECTOR CHECK ASSEMBLY LOCATED OUTSIDE THE
BUILDING. PROVIDE APPROVED DETECTOR CHECK (WATTS DERINGER 30G OR EQUAL) PER CITY STD.
714 REFER SHEET C7.20. FIRE RISERS 8" AMES, SS, AWWA C900 INLET/DIP AND AWWA C606 OUTLET PER
DETAIL 9 ON SHEET C6.01. REFER TO PLUMBING PLANS FOR CONTINUATION
IRRIGATION LINE TO BUILDING POINT OF CONNECTION WITH RP BACFLOW DEVICE PER CITY STD. 712.
REFER TO IRRIGATION PLANS FOR DETAILS
NOTES
A.TRENCH AND BEDDING DETAIL PER CITY OF ARCADIA STD PLAN 702
B.WATER SERVICE CONNECTIONS TO SITE PER SEPARATE PUBLIC IMPROVEMENT PLANS & PERMIT
C.FIRE HYDRANT ASSEMBLY PER SEPARATE PUBLIC WORK IMPROVEMENT PLAN & PERMIT
D.SEWER HOUSE CONNECTION TO SITE PER SEPARATE PUBLIC IMPROVEMENT PLANS & PERMIT
30
31
32
33
34
40
41
42
LEGEND
WATER LINE
FIRE WATER LINE
SANITARY SEWER
CLEANOUT STRUCTURE
GATE VALVE
FIRE HYDRANT
THRUST BLOCK
DRY UTILITY TRENCH
(REFER TO DRY UTILITY PLANS
BY RGI)
3/15/24
CITY OF ARCADIA
DEVELOPMENT SERVICES DIVISION
APPROVED
By
Subject to field inspection approval.
The stamping of this plan and specifications
SHALL NOT be held to permit or to be an
approval of the violation of any provisions
of any City Ordinance, State Law or
Recognized Standard
__________________________K. Fields 03/20/2024
SEWER ONLY
V:
\
1
A
R
C
0
4
0
1
0
0
\
E
N
G
R
\
S
H
E
E
T
S
\
C
7
.
0
0
D
e
t
a
i
l
s
.
d
w
g
3/
1
9
/
2
0
2
4
3
:
4
0
P
M
57
9
0
F
L
E
E
T
S
T
R
E
E
T
,
S
U
I
T
E
1
4
0
CA
R
L
S
B
A
D
,
C
A
9
2
0
0
8
ISSUANCE NAME DATE
AL
E
X
A
N
A
R
C
A
D
I
A
MI
X
E
D
-
U
S
E
/
M
U
L
T
I
-
F
A
M
I
L
Y
H
O
U
S
I
N
G
PR
O
J
E
C
T
27
2
2
0
T
U
R
N
B
E
R
R
Y
L
A
N
E
,
SU
I
T
E
1
9
0
VA
L
E
N
C
I
A
,
C
A
9
1
3
5
5
66
1
.
2
1
9
.
6
0
0
0
50% DD 11/07/22
34
E
.
S
A
N
T
A
C
L
A
R
A
S
T
.
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
100% DD 12/19/22
50% CD 02/13/23
PC SUBMITTAL 04/24/236
5
PC SUBMITTAL 2 08/07/237
VOLUME 03
PC SUBMITTAL 3 12/11/238
PC SUBMITTAL 4 02/12/249
PC SUBMITTAL 5 03/15/2410
NTS
CLEANOUT STURCTURE2
C7.20
UTILITY DETAILS
BE SQUARE OR
CONC. COLLAR MAY
MI
N
.
MI
N
.
GR
A
N
U
L
A
R
M
A
T
E
R
I
A
L
I
N
L
I
E
U
O
F
RE
L
A
T
I
V
E
C
O
M
P
A
C
T
I
O
N
W
I
T
H
1
/
2
"
CO
N
T
R
A
C
T
O
R
M
A
Y
R
E
C
O
M
P
A
C
T
CL
E
A
N
-
O
U
T
E
X
C
A
V
A
T
I
O
N
T
O
M
I
N
.
9
0
%
CO
N
C
R
E
T
E
B
A
S
E
A
N
D
P
I
P
E
S
U
P
P
O
R
T
FO
R
N
O
N
T
R
A
F
F
I
C
A
R
E
A
S
TRAFFIC LOAD
WYE
UNDISTURBED EARTH
PIPE
4" MIN.
1/8 BEND
CONDITION
MAIN
SECTION A-A
2-3/16"
MI
N
.
13
"
B
2" MIN.
4" MIN.
2"
M
I
N
.
B
13
"
MI
N
.
12
"
CLEANOUT FRAME & COVER
PER ALHAMBRA FOUNDRY CO.
PRODUCT NO. A-1240 FOR
6" RISER OR A-1241 FOR
SECTION B-B
OPTIONAL
CONSTRUCTION
CONC. BASE
SUPPORT FOR
8" RISER OR APPROVED
EQUAL
AND WALL
RISER
JOINT MI
N
.
6"
4"
12" MIN.
9"
MIN.
9"
MIN.
12" MIN.
CONCRETE BASE
AND WALL
SUPPORT FOR
TRAFFIC LOAD
CONDITIONS
18" MIN.
13
"
MI
N
.
CIRCULAR
26
"
MI
N
.
24
"
M
I
N
.
12
"
INVERT ELEV.
PER PLAN
INSTALL CAP & SEAL IF
TERMINAL CLEANOUT.
INSTALL PIPE IF IN-LINE
CLEANOUT.
RISER SHALL BE THE SAME
AS MAIN PIPE DIAMETER
DIAMETER AND MATERIAL OF
FOR 6" WITH 3/4" DIA FINGER
HOLE IN CENTER
FINISHED SURFACE
ELEV. PER PLAN
TOP OF CLEAN-OUT
COVER
FRAME
PLAN
A
A
NTS
6" COMPOUND METER1
NTS
THRUST AND ANCHOR BLOCKS 4
NTS
SEWER MANHOLE ADJUSTMENT5
NTS
TRENCH DETAIL3
3/19/24
CITY OF ARCADIA
DEVELOPMENT SERVICES DIVISION
APPROVED
By
Subject to field inspection approval.
The stamping of this plan and specifications
SHALL NOT be held to permit or to be an
approval of the violation of any provisions
of any City Ordinance, State Law or
Recognized Standard
__________________________K. Fields 03/20/2024