Loading...
HomeMy WebLinkAbout12389 Lower Azusa Rd - 2024 - EV Chargers333.21' FS 333.22' FS 333.22' FS 333.24' TC333.23' FS 333.40' TC333.01' FS 333.72' TC333.21' FS 333.69' TC333.18' CE 334.12' BW 333.75' BW 331.57' FS 332.22' FS 332.83' FS 332.46' FS 332.82' FS 333.30' BW 333.31' BW 334.03' BW 334.12' BW 333.98' CE 334.14' CE 333.26' FS 332.92' FS 333.2 0 ' T C 332 . 8 7 ' F S 333.80' TC333.33' BW 333.79' TC333.32' BW 1 2 3 MB IRPI FDCWW EEE BLBLBLBLBL EE EE FDC IRIR E E E FDC W 332 333 334 334 PROJECT DIRECTORY UNDERGROUND SERVICE ALERT APPLICABLE CODES ALL WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: 2020 NATIONAL ELECTRICAL CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA GREEN BUILDING CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE SCOPE OF WORK EROSION CONTROL NOTES: -EROSION AND SEDIMENT CONTROL BEST MANAGEMENT PRACTICES (BMPS) SHALL BE IMPLEMENTED AND MAINTAINED TO MINIMIZE AND/OR PREVENT THE TRANSPORT OF SOIL FROM THE CONSTRUCTION SITE. -APPROPRIATE BMPS FOR CONSTRUCTION RELATED MATERIALS, WASTES, SPILLS, PR RESIDUES SHALL BE IMPLEMENTED TO ELIMINATE OR REDUCE TRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES, OR ADJOINING PROPERTIES BY WIND OR RUNOFF. UNDERGROUND SERVICE ALERT UTILITY NOTIFICATION CENTER OF CALIFORNIA 811 OR (800) 422-4133 3 WORKING DAYS UTILITY NOTIFICATION PRIOR TO CONSTRUCTION CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING LOCATIONS, CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME SHEET INDEX SOUTHERN CALIFORNIA EDISON CHARGE READY PROGRAM SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 -INSTALL ONE (1) NEW 200A, 480/277V, 3PH, 4W METER MAIN SWITCHBOARD "EV-MSB" WITH NEW FOUNDATION -INSTALL ONE (1) NEW 400A, 120/208V, 3PH, 4W DISTRIBUTION PANEL "EV - L1" WITH FOUNDATION -INSTALL ONE (1) NEW 3 PHASE 112.5KVA STEP-DOWN TRANSFORMER 480V-208Y/120V WITH NEW FOUNDATION -INSTALL SEVEN (7) NEW TEMPORARY DUAL TERMINAL BLOCKS WITH FOUNDATIONS FOR FUTURE L2 EV CHARGER. -INSTALL THREE (3) NEW TEMPORARY SINGLE TERMINAL BLOCKS WITH FOUNDATIONS FOR FUTURE L2 EV CHARGER. ADDRESS: SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 PROPERTY OWNER: ALC BUILDING 3 LLCC/O JOHN EDWARDS PO BOX 7368 LA VERNE, CA 91750 ENGINEER OF RECORD: BRYTEMOVE ENERGY RAOUL WOOD, P.E. (909) 477-1474 RAOUL.WOOD@VERIZON.NET SITE DEVELOPER: SALVADOR OLIVAS TRANSPORTATION ELECTRIFICATION PROJECT MANAGEMENT SOUTHERN CALIFORNIA EDISION (SCE) 3 INNOVATION WAY POMONA, CA. 91763 SALVADOR.OLIVAS@SCE.COM (909)930-8512 PROPERTY DESCRIPTION APN:8541017037 SHEET NUMBER SHEET TITLE DATE: SCALE: CHECKED BY: DRAWN BY: REVISION MARK DATE DESCRIPTION PROJECT DEVELOPER PROJECT SITE BRYTEMOVE ENERGY 12 MORGAN IRVINE, CA 92618 TEL: (714) 908-5266 www.brytemove.com V1 11/10/23 CDIFP AS SHOWN 03/22/2024 G-0 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL:(800) 655-4555 RW DLH SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 DWG: C:\Users\DeDe\AppData\Local\Temp\AcPublish_6920\SCE-SAMUEL, SON & CO_AHJ CORRECTIONS_20240116.dwg BY: DeDe Mar 25, 2024 - 8:11:32amPROJ:P- A 01/16/24 AHJ CORRECTIONS B 03/22/24 AHJ CORRECTIONS TITLE PAGE PROJECT COORDINATOR: BRYTEMOVE ENERGY VICTOR CALDERON ENGINEERING PROJECT MANAGER (714) 904-6829 VCALDERON@BRYTEMOVE.COM AREA OF WORK VICINITY MAP SITE MAP SITE LOCATION POWER COMPANY: SOUTHERN CALIFORNIA EDISON (SCE) SHEET #TITLE G-0 TITLE PAGE G-0.1 GENERAL NOTES, SYMBOLS, & ABBREVIATIONS G-0.2 NOTES #2 G-0.3 NOTES #3 G-0.4 NOTES #4 T-1 TOPOGRAPHIC SURVEY DONE BY OTHERS E-1 PLOT PLAN E-1.1 SITE PLAN E-2 DEMOLITION PLAN E-3 LAYOUT DETAIL E-3.1 ELEVATIONS & DETAILS E-3.2 ELEVATIONS & DETAILS E-4 ACCESSIBILITY E-5 ELECTRICAL SINGLE LINE DIAGRAM, PANEL SCHEDULE, CONDUIT & WIRE SCHEDULE E-5.1 TRENCH RUN & DETAIL E-6 SPECIFICATION SHEETS S-1 STRUCTURAL GENERAL NOTES S-2 CONCRETE PAD DESIGN STRUCTURAL ENGINEER: LADERA ENGINEERING GROUP LUIS MENDOZA 71 KYLE COURT LADERA RANCH, CA 92694 ENGINEERING@LADERAEG.COM SHEET NUMBER SHEET TITLE DATE: SCALE: CHECKED BY: DRAWN BY: REVISION MARK DATE DESCRIPTION PROJECT DEVELOPER PROJECT SITE BRYTEMOVE ENERGY 12 MORGAN IRVINE, CA 92618 TEL: (714) 908-5266 www.brytemove.com V1 11/10/23 CDIFP AS SHOWN 03/22/2024 G-0.1 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL:(800) 655-4555 RW DLH SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 DWG: C:\Users\DeDe\AppData\Local\Temp\AcPublish_6920\SCE-SAMUEL, SON & CO_AHJ CORRECTIONS_20240116.dwg BY: DeDe Mar 25, 2024 - 8:11:33amPROJ:P- A 01/16/24 AHJ CORRECTIONS B 03/22/24 AHJ CORRECTIONS GENERAL NOTES, SYMBOLS, & ABBREVIATION ABBREVIATIONS SYMBOLS LIST A, AMPS AMPERES A/C AIR CONDITIONER AC ALTERNATE CURRENT AF AMPERE FRAME AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AIC AMPERE INTERRUPTION CURRENT AL ALUMINUM ARCH ARCHITECT/ARCHITECTURAL AS AMPERE SWITCH AT AMPERE TRIP ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BC BARE COPPER BKBD BACKBOARD BKR BREAKER C CONDUIT CB CIRCUIT BREAKER CAT CATALOG CFSD COMBINATION FIRE SMOKE DAMPER CKT CIRCUIT C.O.CONDUIT ONLY CU COPPER DETL DETAIL DISC DISCONNECT (SWITCH) DIST DISTRIBUTION DP DISTRIBUTION PANEL DWG DRAWING EC ELECTRICAL CONTRACTOR EGC EQUIPMENT GROUND CONDUCTOR (GREEN) EM EMERGENCY EMS ENERGY MANAGEMENT SYSTEM EMT ELECTRICAL METALLIC TUBING EPO EMERGENCY POWER OFF (E)EXISTING EVCS ELECTRIC VEHICLE CHARGING STATION EVSE ELECTRIC VEHICLE SERVICE EQUIPMENT FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL FLA FULL LOAD AMPERES FTV FIELD TO VERIFY (F)FUTURE G, GND GROUND GC GENERAL CONTRACTOR GEC GROUNDING ELECTRODE CONDUCTOR GEN GENERATOR GFI GROUND FAULT INTERRUPTER HP HORSEPOWER HZ HERTZ IBC INTERNATIONAL BUILDING CODE IG ISOLATED GROUND ISC INTERRUPTING SHORT CIRCUIT JB JUNCTION BOX KCMIL THOUSAND CIRCULAR MILLS KV KILOVOLTS KVA KILOVOLT AMPERES KW KILOWATTS KWH KILOWATT HOURS LCL LONG CONTINUOUS LOAD LF LINEAR FEET LCP LIGHT CONTROL PANEL LTG LIGHTING LTS LIGHTS MAX MAXIMUM MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MIN MINIMUM MLO MAIN LOG ONLY MOCP MAX OVERCURRENT PROTECTION MTD MOUNTED MSB MAIN SWITCHBOARD MSG MAIN SWITCHGEAR N NEUTRAL NEC NATIONAL ELECTRICAL CODE NL NIGHT LIGHT NTS NOT TO SCALE (N)NEW OCPD OVERCURRENT PROTECTION DEVICE OH OVERHEAD P POLE PH PHASE PDU POWER DISTRIBUTION UNIT PNL PANEL OR PANELBOARD PVC POLYVINYL CHLORIDE (R)REMOVE REC, RECEPT RECEPTACLE (RL)RELOCATED SPECS SPECIFICATIONS SW SWITCH SWBD SWITCHBOARD THHN THERMOPLASTIC HIGH HEAT RESISTANT NYLON COATED THWN THERMOPLASTIC HEAT AND WATER RESISTANT NYLON COATED TYP TYPICAL UG UNDERGROUND UGPS UNDERGROUND PULL SECTION U.O.N.UNLESS OTHERWISE NOTED V VOLT VA VOLT AMPERES VL VERIFY LOCATION W WATTS WP WEATHERPROOF XFMR TRANSFORMER MOUNTED AT +18" A.F.F. - U.O.N. MOUNTED AT +18" A.F.F. - U.O.N. MOUNTED AT +18" A.F.F. - U.O.N. MOUNTED AT +18" A.F.F. - U.O.N. MOUNTED AT +18" A.F.F. - U.O.N. MOUNTED AT +18" A.F.F. - U.O.N. SUPPLIER PRIOR TO PLACING ORDER. CEILING/BELOW TILE PER A.T.F. AT +18" A.F.F. - U.O.N. AS INDICATED. AS INDICATED. STANDARD 20A, 120V-1Ø GROUNDING TYPE FOUR-PLEX RECEPTACLE MOUNTED DISCONNECT SWITCH. AMPS - VOLTS & POLES AND FUSED OR NON-FUSED MANUAL MOTOR STARTER SWITCH. RATED @ 1H.P. MIN-120V - 1Ø - U.O.N. COMBINATION STARTER DISCONNECT SWITCH. AMPS - VOLTS & POLES "F" DENOTES FLUSH AND "S" DENOTES SURFACE WITHIN FLUSH OR SURFACE FLOOR OUTLET BOX. STANDARD 20A, 120V-1Ø GROUNDING TYPE DUPLEX RECEPTACLE MOUNTED ABOVE STANDARD 20A, 120V-1Ø GROUNDING TYPE DUPLEX RECEPTACLE WALL SPECIAL 30A RECEPTACLE MOUNTED AT +18" A.F.F. -U.O.N.. VOLTS & PHASE AS INDICATED ON PLANS. VERIFY NEMA CONFIGURATION WITH INSTALLED EQUIPMENT PHASE AS INDICATED ON PLANS. VERIFY NEMA CONFIGURATION WITH RELOCATED STANDARD 20A, 120V-1Ø GROUNDING TYPE DUPLEX RECEPTACLE MOUNTED SPECIAL RECEPTACLE MOUNTED AT +18" A.F.F. - U.O.N.. AMPS - VOLTS & STANDARD 20A, 120V-1Ø GROUNDING TYPE SIMPLEX RECEPTACLE, WALL MOUNTED STANDARD 20A, 120V-1Ø GROUNDING TYPE ONE HALF SWITCHED DUPLEX RECEPTACLE STANDARD 20A, 120V-1Ø GROUNDING TYPE DEDICATED DUPLEX RECEPTACLE WALL STANDARD 20A, 120V-1Ø GROUNDING TYPE GFCI FOUR-PLEX RECEPTACLE WALL STANDARD 20A, 120V-1Ø GROUNDING TYPE GFCI DUPLEX RECEPTACLE WALL STANDARD 20A, 120V-1Ø GROUNDING TYPE FOUR-PLEX RECEPTACLE WALL OR NEW INSTALLED EQUIPMENT SUPPLIER PRIOR TO PLACING ORDER. "F" DENOTES FLUSH AND "S" DENOTES SURFACE WITHIN FLUSH OR SURFACE FLOOR OUTLET BOX. TRANSFORMER (SEE SINGLE LINE DIAGRAM) FUSED SWITCH (SEE SINGLE LINE DIAGRAM) AS INDICATED ON PLAN ON PANELBOARD SCHEDULE. T JUNCTION BOX, WALL MOUNTED AT +18" A.F.F. FOR FLEXIBLE CONNECTION TO PRE- WIRED FURNITURE SYSTEM. VERIFY CONNECTION REQUIREMENTS AND LOCATIONS WITH AND/OR CONDUCTORS PASSING THRU ACCORDING TO NEC 2005 TABLE 314-16(a)(b). JUNCTION BOX. SIZED BY THIS CONTRACTOR PER ACTUAL NUMBER OF CONDUITS BRANCH CIRCUIT PANELBOARD. FLUSH OR SURFACE MOUNTED AS INDICATED ELECTRICAL CHARACTERISTICS AND CONNECTION REQUIREMENTS WITH INSTALLED MOTOR OUTLET. H.P. OR F.L.A. - VOLTS & PHASE AS INDICATED. VERIFY MULTI-OUTLET SURFACE RACEWAY ASSEMBLY, TYPE OF OUTLET THERMOSTAT FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. ASSOCIATED HVAC UNIT OR ACCESSIBLE CEILING SPACE. PROVIDE J-BOX BETWEEN +36" to +48" A.F.F. - U.O.N.. PROVIDE 1/2" C.O. TO SERVICE ENTRANCE OR DISTRIBUTION EQUIPMENT AS SPECIFIED. EQUIPMENT MANUFACTURER PRIOR TO ANY ROUGH-IN WORK. FURNITURE MANUFACTURER PRIOR TO ROUGH-IN. PROVIDE COMPLETE WITH THERMAL OVERLOAD PROTECTION. CIRCUIT BREAKER (SEE SINGLE LINE DIAGRAM) MS +18" A.F.F. - U.O.N. 20A, 120V-1Ø ISOLATED GROUND DUPLEX RECEPTACLE WALL MOUNTED AT J 1.PRIOR TO BEGINNING ANY WORK, THE CONTRACTOR SHALL SECURE ALL NECESSARY PERMITS FROM THE AUTHORITIES HAVING JURISDICTION. THE CONTRACTOR SHALL COORDINATE AND OBTAIN APPROVALS FROM ALL RESPECTIVE UTILITY COMPANIES AS REQUIRED FOR A COMPLETE AND OPERATING INSTALLATION. PROVIDE ALL LABOR AND MATERIALS FOR A COMPLETE INSTALLATION. WORK SHALL BE EXECUTED BY EXPERIENCED ELECTRICIANS WHO ARE LICENSED IN THE JURISDICTION WHERE THE PROJECT IS LOCATED. 2.PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO ACHIEVE A COMPLETE AND OPERATING SYSTEM 3.ALL EQUIPMENT SHALL BE NEW, “UL” LISTED, AND LABELED. 4.THE LOCATION OF UNDERGROUND FACILITIES SHOWN ON THE PLANS ARE BASED ON AVAILABLE DOCUMENTATION PROVIDED. IT SHALL BE THE CONTRACTOR'S FULL RESPONSIBILITY TO CONTACT THE VARIOUS UTILITY COMPANIES AND TO PERFORM UTILITY LOCATING SERVICES TO LOCATE THEIR FACILITIES A MINIMUM OF 48 HOURS PRIOR TO STARTING CONSTRUCTION. NO ADDITIONAL COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR DAMAGE AND REPAIR TO THESE FACILITIES CAUSED BY THEIR WORK FORCE. 5.ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY THE ENGINEER. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING AROUND OR NEAR UTILITIES. THE CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS SHALL INCLUDE BUT NOT BE LIMITED TO FALL PROTECTION, CONFINED SPACE, ELECTRICAL SAFETY, AND TRENCHING & EXCAVATION. 6.ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED, CAPPED, PLUGGED OR OTHERWISE DISCONNECTED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, AS DIRECTED BY THE ENGINEER, AND SUBJECT TO THE APPROVAL OF THE OWNER AND/OR LOCAL UTILITIES. 7.ALL DIMENSIONS, GRADES, AND UTILITY LOCATIONS SHOWN ON THESE PLANS WERE BASED ON AVAILABLE DOCUMENTATION PROVIDED. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY PROJECT MANAGER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION FOR NECESSARY CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR WORK HAVING TO BE REDONE DUE TO INFORMATION SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 8.THE CONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH ALL CONTRACT DOCUMENTS, FIELD DOCUMENTS, DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. 9.ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND CITY ORDINANCES. THE CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THEIR WORK. 10.ALL WORK CARRIED OUT SHALL COMPLY WITH APPLICABLE NATIONAL, MUNICIPAL AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND REGULATIONS.UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT. APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATION ON THE DRAWINGS. 11.PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC REPRESENTATION ONLY UNLESS OTHERWISE NOTED. DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT SHALL MAINTAIN THE MINIMUM REQUIRED CODE AND MANUFACTURER CLEARANCES. THEREFORE, IT IS CRITICAL TO FIELD VERIFY DIMENSIONS. SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. 12.IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVAL BY THE ENGINEER PRIOR TO PROCEEDING. 13.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE WORK AREA, ADJACENT AREAS AND ANY BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA REQUIREMENTS AND THE LOCAL JURISDICTION. 14.THE CONTRACTOR SHALL COORDINATE WORK AND SCHEDULE WORK ACTIVITIES WITH OTHER DISCIPLINES. 15.CONSTRUCTION SHALL BE DONE IN A WORKMANLIKE MANNER BY COMPETENT EXPERIENCED WORKMAN IN ACCORDANCE WITH APPLICABLE CODES AND THE BEST ACCEPTED PRACTICE. 16.THE CONTRACTOR SHALL PROVIDE WRITTEN NOTICE TO THE OWNER/CONSTRUCTION MANAGER 48 HOURS PRIOR TO COMMENCEMENT OF WORK. 17.THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE OWNER. 18.ONLY ITEMS SPECIFICALLY CALLED OUT TO BE REMOVED OR DEMOLISHED SHALL BE AFFECTED. ANY ITEMS INCLUDING, BUT NOT LIMITED TO, CURBS, PAVEMENT, UTILITY ITEMS, LANDSCAPING, ETC. SHALL REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION. CONTRACTOR IS RESPONSIBLE TO REPAIR OR REPLACE ANY AFFECTED ITEMS AT OWNERS DISCRETION. 19.CONTRACTOR SHALL MINIMIZE DISTURBANCE TO THE EXISTING SITE DURING CONSTRUCTION AND PROVIDE EROSION AND SEDIMENT CONTROL MEASURES DURING CONSTRUCTION IN COMPLIANCE WITH ALL LOCAL, STATE AND FEDERAL REQUIREMENTS. PROVIDE ALL REQUIRED SILT FENCING, CONSTRUCTION FENCING, STRAW BALES, STORM DRAIN CATCH BASIN INSERTS (SOCKS), ENTRANCE ROCKING, AND ANY OTHER REQUIRED ELEMENTS PRIOR TO COMMENCEMENT OF CONSTRUCTION AND/OR CLEARING THE SITE. 20.THE SUBGRADE SHALL BE BROUGHT TO A SMOOTH UNIFORM GRADE AND COMPACTED TO 95 PERCENT STANDARD PROCTOR DENSITY UNDER PAVEMENT AND STRUCTURES AND 80 PERCENT STANDARD PROCTOR DENSITY IN OPEN SPACE. ALL TRENCHES IN PUBLIC RIGHT OF WAY SHALL BE BACKFILLED WITH FLOWABLE FILL OR OTHER MATERIAL PRE-APPROVED BY THE LOCAL JURISDICTION. 21.THE CONTRACTOR SHALL COORDINATE AND MAINTAIN ACCESS FOR ALL TRADES AND CONTRACTORS TO THE SITE AND/OR BUILDING. 22.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FOR THE DURATION OF CONSTRUCTION UNTIL JOB COMPLETION. 23.THE CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION ONE COMPLETE SET OF APPROVED PLANS WITH ALL REVISIONS, ADDENDA, MANUFACTURERS EQUIPMENT INSTALLATION INSTRUCTIONS AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES. 24.THE CONTRACTOR SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS WITH A RATING OF NOT LESS THAN 2-A OT 2-A:10-B:C AND SHALL BE WITHIN 25 FEET OF TRAVEL DISTANCE TO ALL PORTIONS OF WHERE THE WORK IS BEING COMPLETED DURING CONSTRUCTION. 25.ALL NECESSARY RUBBISH, STUMPS, DEBRIS, STICKS, STONES, AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A LAWFUL MANNER. 26.ALL BROCHURES, OPERATING AND MAINTENANCE MANUALS, CATALOGS, SHOP DRAWINGS, AND OTHER DOCUMENTS SHALL BE TURNED OVER TO THE OWNER AT COMPLETION OF CONSTRUCTION AND PRIOR TO PAYMENT. 27.THE CONTRACTOR SHALL SUBMIT A COMPLETE SET OF AS-BUILT REDLINES TO THE OWNER UPON COMPLETION OF PROJECT AND PRIOR TO FINAL PAYMENT. 28.THE CONTRACTOR SHALL LEAVE PREMISES IN A CLEAN CONDITION. 29.THE CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. 30.SOUNDS ORIGINATING FROM THE CONSTRUCTION SITE, INCLUDING BUT NOT LIMITED TO SOUND FROM CONSTRUCTION EQUIPMENT, POWER TOOLS AND HAMMERING, ARE PROHIBITED BETWEEN THE HOURS OF 10:00 P.M. TO 7:00 A.M. ON WEEKDAYS AND 10:00 P.M. TO 9:00 A.M. ON WEEKENDS. 31.PENETRATIONS OF ALL FIRE RATED WALLS OR CEILINGS SHALL BE FIRE RATED IN ACCORDANCE WITH ALL LOCAL AND NATIONAL CODES. 32.PROVIDE RIVETED ON ENGRAVED PLASTIC NAMEPLATES (RED WITH WHITE LETTERS) FOR ALL MAJOR ELECTRICAL EQUIPMENT. 33.ALL DEVICES MOUNTED BACK TO BACK ON THE FIRE RATED WALL SHALL BE MOUNTED WITH 24" MINIMUM HORIZONTAL OFFSET. J SHEET NUMBER SHEET TITLE DATE: SCALE: CHECKED BY: DRAWN BY: REVISION MARK DATE DESCRIPTION PROJECT DEVELOPER PROJECT SITE BRYTEMOVE ENERGY 12 MORGAN IRVINE, CA 92618 TEL: (714) 908-5266 www.brytemove.com V1 11/10/23 CDIFP AS SHOWN 03/22/2024 G-0.2 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL:(800) 655-4555 RW DLH SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 DWG: C:\Users\DeDe\AppData\Local\Temp\AcPublish_6920\SCE-SAMUEL, SON & CO_AHJ CORRECTIONS_20240116.dwg BY: DeDe Mar 25, 2024 - 8:11:33amPROJ:P- A 01/16/24 AHJ CORRECTIONS B 03/22/24 AHJ CORRECTIONS NOTES #2 PART 1 - GENERAL CLEARING, GRUBBING, STRIPPING, EROSION CONTROL, SURVEY, LAYOUT, SUBGRADE PREPARATION AND FINISH GRADING AS REQUIRED TO COMPLETE THE PROPOSED WORK SHOWN IN THESE PLANS. 1.1 REFERENCES: A.(STATE DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION-CURRENT EDITION). B.ASTM (AMERICAN SOCIETY FOR TESTING AND MATERIALS). C.OSHA (OCCUPATION SAFETY AND HEALTH ADMINISTRATION). 1.2 INSPECTION AND TESTING: A.FIELD TESTING OF EARTHWORK COMPACTION AND CONCRETE CYLINDERS SHALL BE PERFORMED BY AN INDEPENDENT TESTING LAB. THIS WORK TO BE COORDINATED BY THE CONTRACTOR. B.ALL WORK SHALL BE INSPECTED AND RELEASED BY THE GENERAL CONTRACTOR WHO SHALL CARRY OUT THE GENERAL INSPECTION OF THE WORK WITH SPECIFIC CONCERN TO PROPER PERFORMANCE OF THE WORK AS SPECIFIED AND/OR CALLED FOR ON THE DRAWINGS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REQUEST TIMELY INSPECTIONS PRIOR TO PROCEEDING WITH FURTHER WORK THAT WOULD MAKE PARTS OF WORK INACCESSIBLE OR DIFFICULT TO INSPECT. 1.3 SITE MAINTENANCE AND PROTECTION: A.PROVIDE ALL NECESSARY JOB SITE MAINTENANCE FROM COMMENCEMENT OF WORK UNTIL COMPLETION OF THE CONTRACT. B.AVOID DAMAGE TO THE SITE AND TO EXISTING FACILITIES, STRUCTURES, TREES, AND SHRUBS DESIGNATED TO REMAIN. TAKE PROTECTIVE MEASURES TO PREVENT EXISTING FACILITIES THAT ARE NOT DESIGNATED FOR REMOVAL FROM BEING DAMAGED BY THE WORK. C.KEEP SITE FREE OF ALL PONDING WATER. D.PROVIDE EROSION CONTROL MEASURES IN ACCORDANCE WITH STATE DOT, LOCAL PERMITTING AGENCY AND EPA REQUIREMENTS. E.PROVIDE AND MAINTAIN ALL TEMPORARY FENCING, BARRICADES, WARNING SIGNALS AND SIMILAR DEVICES NECESSARY TO PROTECT AGAINST THEFT FROM PROPERTY DURING THE ENTIRE PERIOD OF CONSTRUCTION. REMOVE ALL SUCH DEVICES UPON COMPLETION OF THE WORK. F.EXISTING UTILITIES: DO NOT INTERRUPT EXISTING UTILITIES SERVING FACILITIES OCCUPIED BY THE OWNER OR OTHERS, EXCEPT WHEN PERMITTED IN WRITING BY THE CONSTRUCTION MANAGER AND THEN ONLY AFTER ACCEPTABLE TEMPORARY UTILITY SERVICES HAVE BEEN PROVIDED. G.PROVIDE A MINIMUM 72-HOUR NOTICE TO THE CONSTRUCTION MANAGER AND RECEIVE WRITTEN NOTICE TO PROCEED BEFORE INTERRUPTING ANY UTILITY SERVICE. PART 2 - PRODUCTS 2.1 GRANULAR BACKFILL: SHALL MEET THE FOLLOWING GRADATION: 2.2 GRANULAR BEDDING AND TRENCH BACKFILL: WELL-GRADED SAND MEETING THE GRADATION REQUIREMENTS OF ASTM D2487 (SE OR SW-SM). 2.3 UNSUITABLE MATERIAL: HIGH AND MODERATELY PLASTICS SILTS AND CLAYS (LL>45). MATERIAL CONTAINING REFUSE, FROZEN LUMPS, DEMOLISHED BITUMINOUS MATERIAL, VEGETATIVE MATTER, WOOD, STONES IN EXCESS OF 3 INCHES IN ANY DIMENSION, AND DEBRIS AS DETERMINED BY THE CONSTRUCTION MANAGER. TYPICAL THESE WILL BE SOILS CLASSIFIED BY ASTM AS PT, MH, CH, OH, ML, AND OL. PART 3 - EXECUTION 3.1 GENERAL: A.BEFORE STARTING GENERAL SITE PREPARATION ACTIVITIES, INSTALL EROSION AND SEDIMENT CONTROL MEASURES. THE WORK AREA SHALL BE CONSTRUCTED AND MAINTAINED IN SUCH CONDITION THAT IN THE EVENT OF RAIN THE SITE WILL BE DRAINED AT ALL TIMES. B.BEFORE ALL SURVEY, LAYOUT, STAKING, AND MARKING, ESTABLISH AND MAINTAIN ALL LINES, GRADES, ELEVATIONS AND BENCHMARKS NEEDED FOR EXECUTION OF THE WORK. C.CLEAR AND GRUB THE AREA WITHIN THE LIMITS OF THE SITE. REMOVE TREES, BRUSH, STUMPS, RUBBISH AND OTHER DEBRIS AND VEGETATION RESTING ON OR PROTRUDING THROUGH THE SURFACE OF THE SITE AREA TO BE CLEARED. D.REMOVE THE FOLLOWING MATERIALS TO A DEPTH OF NO LESS THAN 12 INCHES BELOW THE ORIGINAL GROUND SURFACE: ROOTS, STUMPS, AND OTHER DEBRIS, BRUSH, AND REFUSE EMBEDDED IN OR PROTRUDING THROUGH THE GROUND SURFACE, RAKE, DISK OR PLOW THE AREA TO A DEPTH OF NO LESS THAN 6 INCHES, AND REMOVE TO A DEPTH OF 12 INCHES ALL ROOTS AND OTHER DEBRIS THEREBY EXPOSED. E.REMOVE TOPSOIL MATERIAL COMPLETELY FROM THE SURFACE UNTIL THE SOIL NO LONGER MEETS THE DEFINITION OF TOPSOIL. AVOID MIXING TOPSOIL WITH SUBSOIL OR OTHER UNDESIRABLE MATERIALS. F.EXCEPT WHERE EXCAVATION TO GREATER DEPTH IS INDICATED, FILL DEPRESSIONS RESULTING FROM CLEARING, GRUBBING AND DEMOLITION WORK COMPLETELY WITH SUITABLE FILL. G.REMOVE FROM THE SITE AND DISPOSE IN AN AUTHORIZED LANDFILL ALL DEBRIS RESULTING FROM CLEARING AND GRUBBING OPERATIONS. BURNING WILL NOT BE PERMITTED. H.PRIOR TO EXCAVATING, THOROUGHLY EXAMINE THE AREA TO BE EXCAVATED AND/OR TRENCHED TO VERIFY THE LOCATIONS OF FEATURES INDICATED ON THE DRAWINGS AND TO ASCERTAIN THE EXISTENCE AND LOCATION OF ANY STRUCTURE, UNDERGROUND STRUCTURE, OR OTHER ITEM NOT SHOWN THAT MIGHT INTERFERE WITH THE PROPOSED CONSTRUCTION. NOTIFY THE CONSTRUCTION MANAGER OF ANY OBSTRUCTIONS THAT WILL PREVENT ACCOMPLISHMENT OF THE WORK AS INDICATED ON THE DRAWINGS. I.SEPARATE AND STOCK PILE ALL EXCAVATED MATERIALS SUITABLE FOR BACKFILL. ALL EXCESS EXCAVATED AND UNSUITABLE MATERIALS SHALL BE DISPOSED OF OFF-SITE IN A LEGAL MANNER. J.DURING EXCAVATION, THE CONTRACTOR SHALL PROVIDE SHORING, SHEETING, AND BRACING AS REQUIRED TO PREVENT CAVING OR SLOUGHING OF EXCAVATION. K.THE BASE OF ALL FOUNDATION EXCAVATIONS SHOULD BE FREE OF WATER AND LOOSE SOIL PRIOR TO PLACING CONCRETE. CONCRETE SHOULD BE PLACED AS SOON AS POSSIBLE AFTER EXCAVATING TO MINIMIZE BEARING SOIL DISTURBANCE. SHOULD THE SOILS AT BEARING LEVEL BECOME EXCESSIVELY DRY, SATURATED, DISTURBED OR OTHERWISE ALTERED, THE AFFECTED SOIL SHOULD BE REMOVED PRIOR TO PLACING CONCRETE. 3.2 BACKFILL: A.AS SOON AS PRACTICAL, AFTER COMPLETING CONSTRUCTION OF THE RELATED STRUCTURE,INCLUDING EXPIRATION OF THE SPECIFIED MINIMUM CURING PERIOD FOR CAST-IN-PLACE CONCRETE, BACKFILL THE EXCAVATION WITH APPROVED MATERIAL TO RESTORE THE REQUIRED FINISHED GRADE. B.PRIOR TO PLACING BACKFILL AROUND STRUCTURES, ALL FORMS SHALL BE REMOVED AND THE EXCAVATION CLEANED OF ALL TRASH, DEBRIS, AND UNSUITABLE MATERIALS. C.DO NOT PLACE FROZEN MATERIAL IN AS BACKFILL. D.BACKFILL BY PLACING AND COMPACTING SUITABLE BACKFILL MATERIAL OR SELECT GRANULAR BACKFILL MATERIAL WHEN REQUIRED IN UNIFORM HORIZONTAL LAYERS OF NO GREATER THAN 8-INCHES LOOSE THICKNESS AND COMPACTED. WHERE HAND OPERATED COMPACTORS ARE USED, THE FILL MATERIAL SHALL BE PLACED IN LIFTS NOT TO EXCEED 4 INCHES IN LOOSE DEPTH AND COMPACTED. E.WHENEVER THE DENSITY TESTING INDICATES THAT THE CONTRACTOR HAS NOT OBTAINED THE SPECIFIED DENSITY, THE SUCCEEDING LAYER SHALL NOT BE PLACED UNTIL THE SPECIFICATION REQUIREMENTS ARE MET UNLESS OTHERWISE AUTHORIZED BY THE CONSTRUCTION MANAGER. THE CONTRACTOR SHALL TAKE WHATEVER APPROPRIATE ACTION IS NECESSARY, SUCH AS DISKING AND DRYING, ADDING WATER, OR INCREASING THE COMPACTIVE EFFORT TO MEET THE MINIMUM COMPACTION REQUIREMENTS. F.THOROUGHLY COMPACT EACH LAYER OF BACKFILL TO A MINIMUM OF 95 PERCENT OF THE MAXIMUM DRY DENSITY AS PROVIDED BY THE STANDARD PROCTOR TEST, ASTM D 698. 3.3 TRENCH EXCAVATION: A.UTILITY TRENCHES SHALL BE EXCAVATED TO THE LINES AND GRADES SHOWN ON THE DRAWINGS OR AS DIRECTED BY THE GENERAL CONTRACTOR. PROVIDE SHORING, SHEETING AND BRACING AS REQUIRED TO PREVENT CAVING OR SLOUGHING OF THE TRENCH WALLS. B.EXTEND THE TRENCH WIDTH A MINIMUM OF 6 INCHES BEYOND THE OUTSIDE EDGE OF THE OUTERMOST CONDUIT. C.WHEN SOFT YIELDING, OR OTHERWISE UNSTABLE SOIL CONDITIONS ARE ENCOUNTERED, EXCAVATE THE REQUIRED TRENCH TO A DEPTH OF NO LESS THAN 12 INCHES BELOW THE REQUIRED ELEVATION, THEN BACKFILL WITH 12" OF GRANULAR BEDDING MATERIAL. 3.4 TRENCH BACKFILL: A.PROVIDE GRANULAR BEDDING MATERIAL IN ACCORDANCE WITH THE DRAWINGS AND THE UTILITY REQUIREMENTS. B.NOTIFY THE GENERAL CONTRACTOR 24 HOURS IN ADVANCE OF BACKFILLING. C.CONDUCT UTILITY CHECK TESTS BEFORE BACKFILLING. BACKFILL AND COMPACT TRENCH BEFORE ACCEPTANCE TESTING. D.PLACE GRANULAR TRENCH BACKFILL UNIFORMLY ON BOTH SIDES OF THE CONDUITS IN 6-INCH UNCOMPACTED LIFTS UNTIL 12 INCHES OVER THE CONDUITS. SOLIDLY RAM AND TAMP BACKFILL INTO SPACE AROUND CONDUITS. E.PROTECT CONDUIT FROM LATERAL MOVEMENT, IMPACT DAMAGE, OR UNBALANCED LOADING. F.ABOVE THE CONDUIT EMBEDMENT ZONE, PLACE AND COMPACT SATISFACTORY BACKFILL MATERIAL IN 8-INCH MAXIMUM LOOSE THICKNESS LIFTS TO RESTORE THE REQUIRED FINISHED SURFACE GRADE. G.COMPACT FINAL TRENCH BACKFILL TO A DENSITY EQUAL TO OR GREATER THAN THAT OF THE EXISTING UNDISTURBED MATERIAL IMMEDIATELY ADJACENT TO THE TRENCH BUT NO LESS THAN A MINIMUM OF 95 PERCENT OF THE MAXIMUM DRY DENSITY AS PROVIDED BY THE STANDARD PROCTOR TEST, ASTM D 698. 3.5 FINISH GRADING: A.PERFORM ALL GRADING TO PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURES AND SMOOTH, EVEN SURFACE DRAINAGE OF THE ENTIRE AREA WITHIN THE LIMITS OF CONSTRUCTION. GRADING SHALL BE COMPATIBLE WITH ALL SURROUNDING TOPOGRAPHY AND STRUCTURES. B.UTILIZE SATISFACTORY FILL MATERIAL RESULTING FROM THE EXCAVATION WORK IN THE CONSTRUCTION OF FILLS, EMBANKMENTS AND FOR REPLACEMENT OF REMOVED UNSUITABLE MATERIALS. C.REPAIR ALL ACCESS ROADS AND SURROUNDING AREAS USED DURING THE COURSE OF THIS WORK TO THEIR ORIGINAL CONDITION. D.CONTRACTOR TO GRADE SITE TO DRAIN AND NOT POND WATER. 3.6 ASPHALT PAVING: A.CONTRACTOR RESPONSIBLE FOR RE-STRIPING AND APPLYING SEALCOATING PER LOCAL DOT SPECIFICATIONS, UNLESS OTHERWISE SPECIFIED. SIEVE SIZE TOTAL PERCENT PASSING 1 1/2 INCH (37.5 MM)100 1 INCH (25.0 MM)75 TO 100 3/4 INCH (19.00 MM)80 TO 100 3/8 INCH (9.5 MM)35 TO 75 NO. 4 (4.75 MM)35 TO 60 NO. 30 (0.600 MM)7 TO 30 NO. 200 (0.75 MM)3 TO 15 SHEET NUMBER SHEET TITLE DATE: SCALE: CHECKED BY: DRAWN BY: REVISION MARK DATE DESCRIPTION PROJECT DEVELOPER PROJECT SITE BRYTEMOVE ENERGY 12 MORGAN IRVINE, CA 92618 TEL: (714) 908-5266 www.brytemove.com V1 11/10/23 CDIFP AS SHOWN 03/22/2024 G-0.3 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL:(800) 655-4555 RW DLH SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 DWG: C:\Users\DeDe\AppData\Local\Temp\AcPublish_6920\SCE-SAMUEL, SON & CO_AHJ CORRECTIONS_20240116.dwg BY: DeDe Mar 25, 2024 - 8:11:33amPROJ:P- A 01/16/24 AHJ CORRECTIONS B 03/22/24 AHJ CORRECTIONS NOTES #3 6. PROVIDE NONMETALLIC CONDUIT AND TUBING MANUFACTURED BY ONE OF THE FOLLOWING: ANAMET INCORPORATED, ANACONDA METAL HOSE; CANTEX INDUSTRIES, HARSCO CORPORATION; CONDUX INTERNATIONAL, ELECTRICAL PRODUCTS; HUBBELL INCORPORATED,RACO, INCORPORATED; THOMAS & BETTS CORPORATION, CARLON ELECTRICAL PRODUCTS; OR O-Z/GEDNEY, UNIT OF GENERAL SIGNAL. 7. PROVIDE CONDUIT BODIES AND FITTINGS MANUFACTURED BY ONE OF THE FOLLOWING:CROUSE-HINDS, DIVISION OF COOPER INDUSTRIES; EMERSON ELECTRIC COMPANY, APPLETON ELECTRIC COMPANY; HUBBELL INCORPORATED, KILLARK ELECTRIC MANUFACTURING COMPANY;THOMAS & BETTS CORPORATION, CARLON ELECTRICAL PRODUCTS; OR O-Z/GEDNEY, UNIT OF GENERAL SIGNAL. 8. PROVIDE METAL WIREWAYS MANUFACTURED BY ONE OF THE FOLLOWING: HOFFMAN ENGINEERING COMPANY; KEYSTONE/REES, INCORPORATED; OR SQUARED D COMPANY. 9. PROVIDE BOXES, ENCLOSURES, AND CABINETS MANUFACTURED BY ONE OF THE FOLLOWING:CROUSE-HINDS, DIVISION OF COOPER INDUSTRIES; HOFFMAN ENGINEERING COMPANY, FEDERAL-HOFFMAN INCORPORATED; HUBBELL INCORPORATED, RACO INCORPORATED; THOMAS & BETTS, CARLON ELECTRICAL PRODUCTS; O-Z/GEDNEY, UNIT OF GENERAL SIGNAL; ROBROY INDUSTRIES INCORPORATED, ELECTRICAL DIVISION; OR SCOTT FETZER COMPANY, ADALET-PLM. 10. EXPOSED CONDUITS SHALL BE RGS BELOW 10 FEET AND CAN BE EMT ABOVE 10 FEET. THREADED COUPLINGS ON RGS AND STEEL, COMPRESSION ON EMT. C. OUTLET, PULL, AND JUNCTION BOXES 1. EACH SWITCH, LIGHT. RECEPTACLE OR OTHER OUTLET SHALL BE PROVIDED WITH A CODE GAUGE, GALVANIZED STEEL OUTLET BOX. JUNCTION AND PULL BOXES SHALL BE CODE GAUGE, GALVANIZED STEEL. OUTLET BOXES SHALL BE OF THE ONE PIECE, KNOCKOUT TYPE, IN GENERAL 4" SQUARE WITH PLASTER RING. PLASTER RINGS SHALL BE SET TO PROVIDE NOT MORE THAN 1/8" FROM WALL SURFACE TO RING. IN NO CASE SHALL PLASTER RING PROJECT BEYOND SURFACE OF WALL. SINGLE GANG RINGS SIMILAR TO STEEL CITY 52050 SHALL BE USED FOR 4" BOXES IN UNFINISHED BRICK NUMBER 180 BOXES MAY BE USED FOR UNFINISHED MASONRY FLUSH WALL OUTLETS. CENTER ALL OUTLET BOXES IN BLOCK COURSE. 2. BOXES INSTALLED IN POURED CEMENT FLOORS SHALL BE FLUSH TYPE CAST IRON OR STEEL WITH WATERTIGHT GASKETED COVERS. WHERE BOXES ARE INSTALLED IN FLOORS WITH TILE OR CARPET FLOOR COVERING, COVERS SHALL BE OF THE RECESSED TYPE TO ACCOMMODATE THE FLOOR COVERING. 3. ALL JUNCTION BOXES TO BE CAST METAL TYPE FD OR TYPE FS ONLY. D. SWITCHBOARDS 1. PROVIDE SWITCHBOARDS MANUFACTURED IN ACCORDANCE WITH ARTICLE 408 OF THE LATEST NATIONAL ELECTRICAL CODE AND APPLICABLE PORTIONS OF THE NEMA PB2, UL 891 AND NFPA 70, THE NATIONAL ELECTRICAL CODE. 2. CONSTRUCTION: INTEGRATED SWITCHBOARD SHALL BE OF THE MODULAR TYPE CONSTRUCTION, CONSTRUCTED IN ACCORDANCE WITH THE LATEST NEMA PB-2 AND UL 891STANDARDS, WITH THE REQUIRED NUMBER OF VERTICAL SECTIONS BOLTED TOGETHER TO FORM ONE METAL ENCLOSED RIGID INTEGRATED SWITCHBOARD. THE SIDES, TOP AND REAR SHALL BE COVERED WITH REMOVABLE SCREW-ON CODE GAUGE STEEL PLATES. INTEGRATED SWITCHBOARD SHALL INCLUDE ALL PROTECTIVE DEVICES AND EQUIPMENT AS LISTED ON DRAWINGS WITH NECESSARY INTERCONNECTIONS, INSTRUMENTATION AND CONTROL WIRING. ALL GROUPS OF CONTROL WIRES LEAVING THE INTEGRATED SWITCHBOARD SHALL BE PROVIDED WITH TERMINAL BLOCKS WITH SUITABLE NUMBERING STRIPS. SERVICE ENTRANCE INTEGRATED SWITCHBOARD SHALL BE SUITABLE ONLY FOR USE AS SERVICE EQUIPMENT AND BE LABELED IN ACCORDANCE WITH UL REQUIREMENTS. SYSTEM VOLTAGE, AMPERAGE AND INTERRUPTING CAPACITY SHALL BE AS INDICATED ON THE DRAWINGS. ENCLOSURE CONSTRUCTION SHALL BE AS NOTED ON PLANS. 3. BUS: THE BUS SHALL BE OF SUFFICIENT SIZE TO LIMIT THE TEMPERATURE RISE TO 65 DEGREE C, BASED ON UL TESTS (1000A/SQ-IN FOR COPPER) AND SHALL BE FULLY RATED THE ENTIRE LENGTH OF THE INTEGRATED SWITCHBOARD. THE BUS SHALL BE BRACED AND SUPPORTED TO WITHSTAND MECHANICAL FORCES EXERTED DURING A SHORT CIRCUIT FROM A POWER SOURCE HAVING THE AVAILABLE SHORT CIRCUIT CURRENT AS INDICATED ON THE DRAWINGS. PROVIDE A FULL CAPACITY NEUTRAL WHERE A NEUTRAL IS INDICATED ON THE DRAWINGS. THE THROUGH BUS ON THE END SECTION SHALL BE EXTENDED AND PRE-DRILLED TO ALLOW THE ADDITION OF FUTURE SECTIONS. GROUND BUS AND GROUNDING CONDUCTOR LUG SHALL BE FURNISHED. GROUND BUS SHALL EXTEND THE ENTIRE LENGTH OF THE SWITCHBOARD AND SHALL BE FIRMLY SECURED TO EACH VERTICAL SECTION. BUS MATERIAL SHALL BE SILVER-PLATED COPPER. 4. INCOMING UNDERGROUND SERVICE: TO ISOLATE INCOMING UNDERGROUND SERVICE CONDUCTORS, AN UNDERGROUND CABLE PULL OR AUXILIARY SECTION SHALL BE USED WHEN SHOWN ON THE DRAWINGS. THIS SECTION SHALL BE OF THE BUSSED TYPE AND SHALL BE SEALABLE PER LOCAL UTILITY REQUIREMENTS, WHEN REQUIRED. 5.SERVICE SECTION: THE SERVICE SECTION SHALL BE DESIGNED FOR THE SYSTEM PARAMETERS INDICATED AND SHALL HAVE A METERING COMPARTMENT PER UTILITY REQUIREMENTS] AS INDICATED AND SHALL HAVE A MAIN PROTECTIVE DEVICE INDICATED. 6. UTILITY METERING: THE UTILITY METERING SECTION SHALL BE BUILT IN ACCORDANCE WITH REQUIREMENTS AND CODES OF THE LOCAL UTILITY.] 7. DISTRIBUTION SECTIONS: PANEL-MOUNTED, FRONT ACCESSIBLE INDIVIDUAL SECTIONS SHALL BE FRONT ACCESSIBLE, NOT LESS THAN 20” DEEP AND THE REAR OF ALL SECTIONS SHALL ALIGN. INCOMING LINE TERMINATION, MAIN DEVICE CONNECTION AND ALL BOLTS USED TO JOIN CURRENT-CARRYING PARTS SHALL BE INSTALLED SO AS TO PERMIT SERVICING FROM THE FRONT ONLY SO THAT NO REAR ACCESS IS REQUIRED. THE BRANCH DEVICES SHALL BE FRONT REMOVABLE, AND PANEL MOUNTED WITH LINE AND LOAD SIDE CONNECTIONS FRONT ACCESSIBLE. THE INTERIOR SHALL BE CAPABLE OF ACCEPTING PANEL MOUNTED MOLDED CASE CIRCUIT BREAKERS OR FUSIBLE SWITCHES UP TO 1200 AMP RATING. CONSTRUCTION SHALL BE SIEMENS SB TYPE, OR APPROVED EQUAL. 8. FINISH: THE COMPLETE SWITCHBOARD SHALL BE PHOSPHATIZED AND FINISHED WITH ANSI 61 LIGHT GRAY POLYESTER POWDER PAINT. 9. MARKINGS: EACH SWITCHBOARD SECTION SHALL HAVE A LABEL PERMANENTLY AFFIXED TO IT, LISTING THE FOLLOWING INFORMATION: NAME OF MANUFACTURER, SYSTEM VOLTAGE, AMPACITY, TYPE, MANUFACTURER'S SHOP ORDER NUMBER AND DATE. EACH SECTION OF SWITCHBOARD SHALL BEAR A UL LISTING MARK, WHERE QUALIFIED AND A SHORT CIRCUIT RATING LABEL.FRONT, SIDE, REAR AND TOP OF EACH SWITCHBOARD SECTION WILL HAVE A DANGER LABEL IN ACCORDANCE WITH NEMA STANDARD PB-2. E. PANEL BOARDS 1. PROVIDE PANELBOARDS MANUFACTURED IN ACCORDANCE WITH ARTICLE 408 OF THE LATEST NATIONAL ELECTRICAL CODE AND APPLICABLE PORTIONS OF THE NEMA PB1, UL50, UL 67 AND NFPA 70, THE NATIONAL ELECTRICAL CODE. 2. PANELBOARDS SHALL BE ENCLOSED DEAD FRONT SAFETY TYPE WITH FEATURES AND RATINGS AS SCHEDULED ON DRAWINGS. ALL BUS BARS SHALL BE RECTANGULAR SOLID COPPER. A 'PROVISION' CIRCUIT DESCRIPTION WHERE SHOWN IN PANEL SCHEDULES, DESIGNATES SPACE FOR FUTURE PROTECTIVE DEVICES AND SHALL INCLUDE BUS AND SUPPORT. PANELS KNOWN AS "LOAD CENTERS" ARE UNACCEPTABLE. 3. MOLDED CASE CIRCUIT BREAKERS SHALL BE AS SCHEDULED ON THE DRAWINGS AND SPECIFIED IN THIS DIVISION. ALL BREAKERS SHALL BE BOLT ON TYPE. 4. ALL BOLTED CONNECTIONS SHALL BE TORQUED IN ACCORDANCE WITH MANUFACTURERS STANDARDS. RETORQUE ALL CONNECTIONS ONE MONTH AFTER INITIAL TORQUE. 5. INSTALL CABINETS SO THAT CENTER OF THE TOP BREAKER DOES NOT EXCEED 6'-6" ABOVE THE FINISHED FLOOR. 6. ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS AS NEAR AS POSSIBLE TO CIRCUIT NUMBERS ON THE DRAWINGS. AT COMPLETION OF JOB, ELECTRICAL CONTRACTOR SHALL TAKE CURRENT READING CHECKS OF RESPECTIVE PHASES. A MINIMUM OF CIRCUIT CONNECTIONS SHALL BE REARRANGED TO BALANCE, AS CLOSELY AS POSSIBLE, THE LOAD IN THE PANEL. ENTRIES ON DIRECTORY CARDS SHALL BE TYPED, COMPLETE AND ACCURATE. 7. MANUFACTURER SHALL BE SQUARE D, SIEMENS, OR EATON CUTLER-HAMMER. F. METERED COMMERCIAL PEDESTAL ACCEPTABLE MANUFACTURER: MILBANK OR APPROVED EQUAL AMPACITY: AS NOTED ON PLANS VOLTAGE: AS NOTED ON PLANS SCCR RTATING: AS NOTED ON PLANS 1. THE PEDESTAL SHALL BE OF TYPE 3R RAINPROOF CONSTRUCTION AND SHALL BE UL LISTED. EXTERNAL CONSTRUCTION SHALL COMPLY WITH UL50 REQUIREMENTS AND SHALL BE OF G90 GALVANIZED STEEL WITH LIGHT GREEN #14672 FEDERAL SPECIFICATION 595 POLYURETHANE INDUSTRIAL GRADE POWDER PAINT OF 1.7 MIL MINIMUM THICKNESS (UNLESS OTHERWISE SPECIFIED). ALUMINUM AND STAINLESS STEEL ARE OTHER FACTORY OPTIONS AVAILABLE. INTERNAL CONSTRUCTION SHALL BE G90 GALVANIZED STEEL AND 1.7 MIL MINIMUM THICKNESS POLYURETHANE INDUSTRIAL GRADE POWDER COAT PAINTED OR BARE ALUMINUM. NO FASTENERS EXCEPT SEALING SCREWS SHALL BE REMOVABLE BY EXTERNAL ACCESS. HINGES SHALL BE STAINLESS STEEL AND OF THE CONTINUOUS PIANO HINGE TYPE. 2. THE PEDESTAL MOUNTING BOLTS SHALL NOT BE EXTERNALLY ACCESSIBLE. THE PEDESTAL SHALL BE OFFERED WITH AN OPTIONAL BASE DESIGNED TO BE EMBEDDED IN CONCRETE IN PLACE OF ANCHOR BOLTS. EITHER PEDESTAL MOUNTING BASE OR ANCHOR BOLT KIT IS REQUIRED FOR INSTALLATION. 3. THE SERVICE PEDESTAL MUST HAVE THREE SEPARATE ISOLATED SECTIONS FOR METERING EQUIPMENT, UTILITY TERMINATION AND CUSTOMER EQUIPMENT. 4. THE METERING SECTION MUST BE PAD-LOCKABLE AND SEALABLE AND HAVE A HINGED SWING BACK HOOD WITH AN INTEGRAL HINGED POLYCARBONATE SEALABLE WINDOW FOR ACCESS TO DEMAND METERS. AN EXTERNAL NAMEPLATE SHALL BE PERMANENTLY ATTACHED TO THE HOOD. A STAINLESS-STEEL HANDLE SHALL BE PROVIDED ON THE FRONT EXTERIOR OF THE HOOD. METER SOCKET TYPE SHALL MEET THE REQUIREMENTS OF THE SERVING UTILITY. 5. THE UTILITY TERMINATION SECTION MUST BE PAD-LOCKABLE AND SEALABLE AND SHALL HAVE A STAINLESS-STEEL HANDLE PROVIDED ON A LIFT-OFF COVER. SUFFICIENT CLEARANCE SHALL BE PROVIDED FOR A 4-INCH DIAMETER CONDUIT FOR UTILITY CABLES ENTRANCE. UTILITY LANDING LUGS SHALL ACCOMMODATE #6 – 350 KCMIL CONDUCTORS. 6. THE CUSTOMER COMPARTMENT DOOR TO BE HINGED ON THE LEFT-HAND SIDE. A STAINLESS PAD-LOCKABLE HASP PROVIDED TO SECURE CUSTOMER COMPARTMENT. A DOOR KEEPER PROVIDED TO KEEP THE DOOR IN AN OPEN POSITION. A PRINT POCKET ON THE INSIDE OF THE DOOR SHALL HOLD ALL WIRING SCHEMATICS, CIRCUIT DIRECTORIES AND INSTRUCTIONS IN A CLEAR, WEATHERPROOF SLEEVE. REQUIRED LABELING SHALL BE LOCATED ON THE INSIDE OF THE CUSTOMER DOOR. DISTRIBUTION AND CONTROL EQUIPMENT SHALL BE BEHIND AN INTERNAL DEAD-FRONT DOOR WITH A QUARTER-TURN SECURING LATCH AND BE HINGED TO OPEN MORE THAN 90 DEGREES. THE DEADFRONT DOOR SHALL BE HINGED ON THE SAME SIDE AS THE CUSTOMER SECTION DOOR. ALL DISTRIBUTION AND CONTROL EQUIPMENT SHALL BE FACTORY WIRED USING 600 VOLT WIRE SIZED TO UL REQUIREMENTS. 7. THE PROVIDED DOCUMENTATION SHALL LIST CIRCUIT BREAKER COMBINATIONS AND THOSE TO BE USED FOR DE-RATED OPERATION FOR SERIES RATINGS. G. TRANSFORMERS ACCEPTABLE MANUFACTURER: EATON OR APPROVED EQUAL DRY TYPE, INDOOR/OUTDOOR, CONVECTION-COOLED, TRANSFORMER CHARACTERISTICS AS FOLLOWS: 1.RATING & VOLTAGES: AS INDICATED ON DRAWINGS 2.IMPEDANCE AT 115C: STANDARD 3.PRIMARY AND SECONDARY COIL MATERIAL: COPPER 4.CORE MATERIAL: HIGH-GRADE, NON-AGING, SILICON ELECTRICAL STEEL 5.ANGULAR DISPLACEMENT: SECONDARY LAGGING PRIMARY BY 30 (IEC: DY1) 6.VOLTAGE TAPS: 2 – 2½% FCAN, 2 – 2½% FCBN, SILVER PLATED. TAPS TO BE BOLTED-LINK TYPE AND LOCATED AT FRONT OF COILS FOR ACCESSIBILITY 7.INSULATION CLASS: 220°C 8.TEMPERATURE RISE: 150°C 9.PROVIDE MEANS FOR SECURING ALL CONDUCTORS WITHIN ENCLOSURE. 10.EFFICIENCY: 97.89% MINIMUM PER DOE 2016 EFFECIENCY LEVELS (CFR TITLE 10) 11.ENCLOSURE: MINIMUM NEMA 3R OR 4X TO SUIT ENVIRONMENT. 12.SOUND LEVEL: PER NEMA ST-20 (2014) 13.CONDUCTOR ENTRY: SIDE. 14.PROVIDE ANTI-VIBRATION PADS OR ISOLATORS BETWEEN THE CORE/COIL AND ENCLOSURE. 15.PROVIDE VIBRATION ISOLATORS FOR ALL TRANSFORMERS. H. CONDUCTORS AND CABLES 1. WIRING - ALL CONDUCTORS SHALL BE EQUAL TO OR BETTER THAN MINIMUM #12 AWG FOR POWER, #14 AWG FOR CONTROL WITH 98% CONDUCTIVITY STRANDED COPPER WITH TYPE (THWN-2) INSULATION, 600V, COLOR CODED. PROVIDE 75 DEGREE RATED CONDUCTORS FOR AMPACITES ABOVE 100 AMPS AND 60 DEGREE RATED CONDUCTORS FOR AMPACITIES OF 100 AMPS OR LESS. PROVIDE SOLID OR STRANDED FOR #10 AWG AND SMALLER, STRANDED FOR #8 AWG AND LARGER U.N.O. 2. WIRE SIZE OF BRANCH CIRCUITS SHALL BE ADJUSTED TO COMPENSATE FOR VOLTAGE DROP BASED UPON ACTUAL CONDUIT ROUTING. CONTRACTOR SHALL MAINTAIN VOLTAGE DROP AS RECOMMENDED BY NEC (NOT TO EXCEED 3%). 3. PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT, FEEDER, ETC. NEUTRALS ARE NOT PERMITTED TO BE SHARED. 4. CONNECTORS FOR POWER CONDUCTORS: CONTRACTOR SHALL USE PRESSURE TYPE INSULATED TWIST-ON CONNECTORS FOR #10 AWG AND SMALLER. USE SOLDERLESS MECHANICAL TERMINAL LUGS FOR #8 AWG AND LARGER. 5. ALL CONNECTIONS SHALL BE MADE WITH A PROTECTIVE COATING OF AN ANTI-OXIDE COMPOUND SUCH AS "NO-OXIDE A" BY DEARBORNE CHEMICAL CO. COAT ALL WIRE SURFACES BEFORE CONNECTING. EXPOSED COPPER SURFACE, INCLUDING GROUND BARS, SHALL BE TREATED - NO SUBSTITUTIONS. 6. MC CABLE IS NOT PERMITTED. 7. CONDUCTOR COLOR CODES: ·GROUND WIRES: GREEN, GREEN WITH A YELLOW STRIPE, OR BARE COPPER ·NEUTRAL WIRES: WHITE OR GRAY ·SINGLE PHASE LIVE WIRES: BLACK (OR RED FOR A SECOND “HOT” WIRE) ·208 VAC, 3-PHASE: BLACK, RED AND BLUE ·480 VAC, 3-PHASE: BROWN, YELLOW, PURPLE 8. PROVIDE WIRE AND CABLE MANUFACTURED BY ONE OF THE FOLLOWING: AMERICAN INSULATED WIRE CORPORATION; NEXANS; CERROWIRE; SOUTHWIRE; OR ENCORE WIRE. 9. PROVIDE CONNECTORS MANUFACTURED BY ONE OF THE FOLLOWING: AMP INCORPORATED; GENERAL SIGNAL, O-Z/GEDNEY UNIT; SQUARE D COMPANY, ANDERSON; ILSCO; OR BURNDY. ALUMINUM CONDUCTOR REQUIREMENTS 1. ALUMINUM CONDUCTOR GRADE SHALL BE MINIMUM AA-8000 OR NEWEST ALUMINUM CONDUCTOR SPECIFICATION BEING USED BY THE INDUSTRY. 2. THE CONTRACTOR SHALL ABIDE BY ALL ARTICLES RELATED TO ALUMINUM CONDUCTORS IN THE LATEST ISSUE OF THE NEC. 3. ALUMINUM CONDUCTORS SHALL ONLY BE TERMINATED USING ALUMINUM RATED CONNECTIONS. CONTRACTOR SHALL VERIFY TERMINATIONS ON EACH DEVICE OR EQUIPMENT BEFORE START OF WORK FOR RATED ALUMINUM CONNECTORS. 4. THE CONTRACTOR SHALL ABIDE BY ALL ALUMINUM WIRING INSTALLATION STANDARDS AS REQUIRED BY THE NEIS (NATIONAL ELECTRICAL INSTALLATION STANDARDS) PUBLISHED BY THE NECA (NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION). THE CONTRACTOR SHALL ABIDE BY ALL STANDARDS IN THE NECA/AA-2006, WHICH DEFINES MINIMUM STANDARDS OF QUALITY AND WORKMANSHIP. A SUMMARY OF SOME OF THE REQUIREMENTS FOLLOW: A.TERMINATE WITH COMPRESSION CONNECTORS, NO RING CUTS OF THE INSULATION, CRIMP ONLY WITH A CRIMP TOOL AND THE CORRECT DIE AS REQUIRED BY THE MANUFACTURER. B.ALL CONDUCTORS TO RECEIVE ANTI-OXIDATIVE COATING DURING INSTALLATION. C.TERMINATING WITH SET SCREW CONNECTOR, THE SCREW SHALL BE TIGHTENED USING ONLY A TORQUE WRENCH. D.NECA/AA RECOMMENDS BELLVILLE WASHERS WHEN CONNECTING ALUMINUM CONDUCTORS TO COPPER BUS BARS. ABIDE BY ALL NECA/AA RECOMMENDATIONS. E.DO NOT USE PIN CONNECTORS (WIRE ADAPTERS) UNLESS ABSOLUTELY NECESSARY. USE ALL / ANY OTHER OPTIONS, AND IF REQUIRED, PROVE TO ENGINEER BEFORE INSTALLING. IF USED, FOLLOW UL GUIDE FOR WIRE CONNECTORS (ZMOW), AND PROVIDE THE SPECIAL TOOLS REQUIRED BY THE MANUFACTURER. DIE-LESS CRIMPERS WILL NOT BE ACCEPTED.. I.WIRING DEVICES 1.WALL SWITCHES SHALL BE SPECIFICATION GRADE AC SILENT TYPE SWITCHES, 20A, 120/277 VOLT. 2.RECEPTACLES SHALL BE SPECIFICATION GRADE, DUPLEX TYPE, NEMA 5-20R, 20 AMPERE, 120 VOLT GROUNDED TYPE. SPECIAL APPLICATION RECEPTACLES SHALL BE INDICATED ON PLANS. MOUNT WITH THE GROUND DOWN. 3.DEVICE PLATES SHALL BE EQUAL TO SIERRA SMOOTH-LINE PLASTIC WALL PLATES. COLOR SHALL BE WHITE, UNLESS OTHERWISE NOTED. J.SAFETY SWITCHES 1.ALL DISCONNECT SWITCHES SHALL BE HEAVY-DUTY CONSTRUCTION WITH LOCKABLE HANDLES SIZED AS NOTED ON THE DRAWINGS. PROVIDE NEMA ENCLOSURE AS REQUIRED BY CODE AND AMBIENT CONDITIONS. ALL FUSIBLE SWITCHES SHALL BE PROVIDED WITH DUAL ELEMENT FUSES SIZED PER THE EQUIPMENT MANUFACTURER'S RECOMMENDATION. K.FUSES 1.FUSED SHALL BE DUAL ELEMENT, TIME DELAY CURRENT LIMITING. CONTRACTOR SHALL COORDINATE FUSE SIZES WITH EQUIPMENT MANUFACTURER'S REQUIREMENTS AND PER THE NEC. 2.PROVIDE FUSES MANUFACTURED FROM ONE OF THE FOLLOWING: COOPER BUSSMAN, INCORPORATED; EAGLE ELECTRIC MANUFACTURING COMPANY INCORPORATED, COOPER INDUSTRIES INCORPORATED; FERRAZ SHAWMUT INCORPORATED. L.ELECTRICAL IDENTIFICATION 1.PROVIDE ENGRAVED PHENOLIC PLASTIC NAMEPLATES FOR ALL MAJOR ELECTRICAL EQUIPMENT (INCLUDED BUT NOT LIMITED TO TRANSFORMERS, DISCONNECT SWITCH, SWITCHBOARD, PANELBOARD, CHARGING CABINET, CHARGE POST, OVER-CURRENT PROTECTION DEVICE IN MAIN SWITCHBOARD, ETC.) AND ON EQUIPMENT AS DIRECTED BY OWNER. 2.PROVIDE ALL FEEDERS AND BRANCH CIRCUIT WIRING WITH COLOR CODED (SEE CONDUCTORS AND CABLES) VINYL TAPE WRAPPED A MINIMUM OF 1.5 TIMES AROUND CIRCUMFERENCE OF JACKET/SHIELDING TO DESIGNATE PHASE. 3.COLOR CODING OF CONDUCTORS SHALL BE PER THE NEC AND OWNERS REQUIREMENTS. 4.CONTRACTOR SHALL PLACE TWO LENGTHS OF WARNING TAPE AT A DEPTH OF 12" BELOW GROUND AND DIRECTLY ABOVE ELECTRICAL SERVICE CONDUITS. CAUTIONS TAPE TO READ "CAUTION BURIED ELECTRIC". M.SYSTEM GROUNDING AND BONDING 1.GROUNDING AND BONDING SHALL COMPLY WITH REQUIREMENTS OF NEC ARTICLE 250. ALL EXPOSED NONCURRENT CARRYING METALLIC PARTS OF ELECTRICAL EQUIPMENT, METALLIC RACEWAY SYSTEMS, METALLIC CABLE ARMOR, GROUNDING CONDUCTOR OF NONMETALLIC SHEATHED CABLES, GROUNDING CONDUCTOR IN NONMETALLIC RACEWAYS, AND GROUNDED CONDUCTORS OF THE WIRING SYSTEM SHALL BE GROUNDED. 2.A GROUND BUS SEPARATE FROM THE NEUTRAL BUS SHALL BE PROVIDED IN ALL SWITCHBOARDS AND PANELBOARDS. GROUND BUS SHALL BE RETORQUED (CHECKED) PRIOR TO ENERGIZING EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. 3.GROUND BUSES AND NEUTRAL BUSES IN ALL DISTRIBUTION PANELS, SWITCHBOARDS, PANELBOARDS, AND THOSE PROVIDED IN ANY EQUIPMENT SHALL BE ISOLATED EXCEPT WHERE REQUIRED TO BE CONNECTED AS SPECIFIED ABOVE FOR THE SERVICE ENTRANCE AND IN TRANSFORMER TERMINAL COMPARTMENTS. 4.WHEN INDICATED ON THE DRAWINGS, EQUIPMENT GROUNDING CONDUCTORS SHALL BE EXTENDED FROM THE GROUND BUS IN THE DISTRIBUTION EQUIPMENT TO THE RECEPTACLE, FIXTURE OR DEVICE LUGS WHERE THEY ARE PROVIDED. WHERE LUGS ARE NOT PROVIDED, EQUIPMENT GROUNDING CONDUCTORS SHALL BE CONNECTED TO EQUIPMENT ENCLOSURES. THE CONNECTIONS SHALL BE ARRANGED SUCH THAT REMOVAL OF THE RECEPTACLE, EQUIPMENT GROUND CONDUCTORS, OR GROUND JUMPERS FROM GROUND BUSING SHALL NOT AFFECT THE GROUND SYSTEM. 5.RACEWAYS MAY NOT BE USED AS A GROUNDING CONDUCTOR FOR POWER AND LIGHTING CIRCUITS. ALL CONDUIT SHALL HAVE SEPARATE CODE SIZED GREEN GROUND WIRE INSTALLED IN THE CONDUIT TO INSURE A CONTINUOUS GROUNDING PATH. 6.EQUIPMENT GROUNDING CONDUCTORS SHALL BE INSULATED WITH GREEN-COLORED INSULATION. 7.GROUNDING ELECTRODE CONDUCTORS SHALL BE STRANDED CABLE. 8.MATERIALS AND CONNECTION COMPONENTS FOR GROUNDING AND BONDING SHALL BE MANUFACTURED BY ERICO, THOMAS & BETTS, BURNDY, OR EQUAL. N.FIRESTOPPING AND SEALING ELECTRICAL PENETRATIONS 1.CONTRACTOR SHALL FURNISH AND INSTALL FIRESTOPPING FOR SEALING AROUND ELECTRICAL PENETRATIONS THROUGH FIRE OR SMOKE BARRIERS, AND FLOORS. 2.PROVIDE SHOP DRAWINGS OF EACH CONDITION REQUIRING PENETRATION SEALS AND THE PROPOSED UL SYSTEMS MATERIALS, ANCHORAGE, METHODS OF INSTALLATION, AND ACTUAL ADJACENT CONSTRUCTION. SUBMITTAL PACKAGE SHALL ALSO INCLUDE A COPY OF THE UL ILLUSTRATION OF EACH PROPOSED SYSTEM INDICATING MANUFACTURER APPROVED MODIFICATIONS (IF APPLICABLE) AND THE MANUFACTURER'S SPECIFICATIONS, RECOMMENDATIONS, INSTALLATION INSTRUCTIONS, AND MAINTENANCE INSTRUCTIONS. 3.FIRESTOPPING MATERIALS SHALL BE INTUMESCENT SAFETY BARRIERS DESIGNED TO BLOCK THE SPREAD OF FIRE AND SMOKE THROUGH PENETRATIONS CREATED BY ELECTRICAL INSTALLATIONS IN FIRE RATED WALLS AND FLOORS. MATERIALS SHALL BE FLAME, TOXIC FUME, AND WATER RESISTANT AND SHALL HAVE A MINIMUM 3 HOUR FIRE RATING. FIRE RATING SHALL BE DEFINED BY TESTS CONDUCTED BY ASTM, UL OR OTHER TESTING AND INSPECTION AGENCIES ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. 4.PROVIDE MATERIALS BY THE FOLLOWING MANUFACTURERS TO SUIT THE APPLICATION: SPECIFIED TECHNOLOGIES, INC (STI), SOMERVILLE, NJ; TREMCO, INC., BEACHWOOD, OH; OR 3M INC., MINNEAPOLIS, MN. O.SHOP DRAWINGS AND APPROVALS 1.COORDINATES, PREPARE AND SUBMIT SHOP DRAWINGS TO THE OWNER AND ENGINEER FOR THEIR REVIEW. CONTRACTOR SHALL REVIEW AND INDICATE HIS APPROVAL OF EACH SHOP DRAWING PRIOR TO SUBMITTAL FOR REVIEW. DO NOT ORDER, START WORK OR FABRICATION UNTIL SHOP DRAWINGS HAVE BEEN REVIEWED BY THE ENGINEER AND RETURNED TO THE CONTRACTOR. SHOP DRAWINGS TO BE SUBMITTED INCLUDE, BUT NOT LIMITED TO: ·SWITCHBOARDS ·PANEL BOARDS ·SAFETY SWITCHES ·TRANSFORMERS ·CONTACTORS ·LIGHTING FIXTURES ·UNDERGROUND CONDUIT COORDINATION DRAWING SHOWING ACTUAL ROUTING AND BURIAL DEPTH COORDINATED WITH ALL OTHER EXISTING AND NEW UNDERGROUND PIPING AND CONDUIT. 2.CLEARLY IDENTIFY EACH ITEM ON THE SUBMITTAL AS TO MARK, LOCATION AND USE, USING SAME IDENTIFICATION AS PROVIDED ON DESIGN DRAWINGS. ELECTRONIC SUBMITTALS SHALL BE PRESENTED WITH ALL SHEETS IN ALPHANUMERIC ORDER AND ALL SHEETS ORIENTED WITH TOP OF SHEET UP. 3.SUBMITTALS WILL BE REVIEWED ONLY FOR GENERAL COMPLIANCE WITH THE CONTRACT DOCUMENTS AND NOT FOR DIMENSIONS OR QUANTITIES. THE SUBMITTAL REVIEW SHALL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR PURCHASE OF ANY ITEM IN FULL COMPLIANCE WITH THE CONTRACT DOCUMENTS OR ITS COMPLETE AND PROPER INSTALLATION. ELECTRICAL SPECIFICATIONS SHEET NUMBER SHEET TITLE DATE: SCALE: CHECKED BY: DRAWN BY: REVISION MARK DATE DESCRIPTION PROJECT DEVELOPER PROJECT SITE BRYTEMOVE ENERGY 12 MORGAN IRVINE, CA 92618 TEL: (714) 908-5266 www.brytemove.com V1 11/10/23 CDIFP AS SHOWN 03/22/2024 G-0.4 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL:(800) 655-4555 RW DLH SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 DWG: C:\Users\DeDe\AppData\Local\Temp\AcPublish_6920\SCE-SAMUEL, SON & CO_AHJ CORRECTIONS_20240116.dwg BY: DeDe Mar 25, 2024 - 8:11:34amPROJ:P- A 01/16/24 AHJ CORRECTIONS B 03/22/24 AHJ CORRECTIONS NOTES #4 ELECTRICAL SPECIFICATIONS P. RECORD AND AS-BUILT DRAWINGS 1. THE ELECTRICAL CONTRACTOR SHALL MAINTAIN AN APPROVED SET OF DRAWINGS AT THE JOB SITE FOR THE EXCLUSIVE PURPOSE OF MAINTAINING AN ONGOING RECORD OF HOW ALL WORK IS INSTALLED AND TO SHOW ANY DEVIATIONS FROM THE WORK AS INDICATED ON THE DRAWINGS. 2. THE ELECTRICAL CONTRACTOR SHALL SUBMIT ONE (1) COMPLETE SET OF RECORD DOCUMENTS TO THE CONSTRUCTION MANAGER FOR THE OWNER'S RECORDS. CONTRACTOR SHALL SUBMIT THESE “AS-BUILT” SET OF PLANS TO WITHIN 7 DAYS OF COMPLETION OF CONSTRUCTION AND PRIOR TO FINAL PAYMENT. Q. GUARANTEE 1. GUARANTEE ALL MATERIAL FURNISHED AND ALL WORKMANSHIP PERFORMED FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE OF WORK. ANY DEFECTS DEVELOPING WITHIN THIS PERIOD, TRACEABLE TO MATERIAL FURNISHED AS A PART OF THIS SECTION OR WORKMANSHIP PERFORMED HEREUNDER, SHALL BE MADE GOOD AT NO EXPENSE TO THE OWNER. PART I - GENERAL 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS BEFORESTARTING WORK AND SHALL NOTIFY ENGINEER OF RECORD (EOR) OF ANY DISCREPANCIES. 2. ALL MATERIAL AND WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 2022 CBC. 3. NEITHER THE OWNER NOR (EOR) WILL ENFORCE SAFETY MEASURES OR REGULATIONS. THE CONTRACTOR SHALL DESIGN, CONSTRUCT, AND MAINTAIN ALL SAFETY DEVICES INCLUDING SHORING AND BRACING, AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STUCTURE AND DO NOT INDICATE METHODS, PROCEDURES OR SEQUENCE OF CONSTUCTION. THE CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO MAINTAIN AND INSURE THE INTEGRITY OF THE STRUCTURE DURING CONSTRUCTION. IF A LAWSUIT IS FILED BY ONE OF THE CONTRACTOR'S OR SUBCONTRACTOR'S EMPLOYEES, OR ANY ONE ELSE, THE CONTRACTOR WILL INDEMNIFY, DEFEND AND HOLD THE OWNER AND (EOR) HARMLESS OF ANY AND ALL SUCH CLAIMS. 4. NO PIPES, DUCTS, SLEEVES, CHASE ETC., SHALL BE PLACED IN SLABS, BEAMS, COLUMNS, WALLS, ETC., UNLESS SPECIFICALLY SHOWN OR NOTED. NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC., UNLESS SPECIFICALLY SHOWN. OBTAIN PRIOR WRITTEN APPROVAL FOR INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, ETC. FOUNDATION REQUIREMENTS: VERTICAL LOADS: ALLOWABLE BEARING PRESSURE: 1500 PSF (TOTAL LOADS) LATERAL LOADS: PASSIVE RESISTANCE:100 PCF FRICTION FACTOR:0.25 (BETWEEN CONCRETE AND SOIL) FOOTING SHOULD HAVE AT LEAST FIVE (5) FEET OF HORIZONTAL CLEARANCE BETWEEN THE BOTTOM OF FOOTING AND THE FACE OF THE NEAREST SLOPE. SLAB-ON-GRADE: SLAB-ON-GRADE SHOULD BE SUPPORTED ENTIRELY ON BEDROCK OR ENTIRELY ON NON-EXPANSIVE, COMPACTED ENGINEERED FILL OF RELATIVELY UNIFORM THICKNESS. THE ENGINEERED FILL SPECIFICATION SHALL HAVE A MINIMUM RELATIVE COMPACTION OF 90% PER ASTM D-1557. REINFORCED CONCRETE NOTES: 1. CEMENT SHALL CONFORM TO ASTM C-150, TYPE II. 2. AGGREGATES SHALL CONFORM TO ASTM C-33 FOR NORMAL WEIGHT CONCRETE AND ASTM C-330 FOR LIGHT WEIGHT CONCRETE. 3. ALL REINFORCING STEEL, ANCHOR BOLTS, DOWELS AND OTHER INSERTS SHALL BE SECURED IN POSITION AND INSPECTED BY THE LOCAL BUILDING DEPARTMENT INSPECTOR PRIOR TO THE POURING OF ANY CONCRETE. 4. CONCRETE SHALL MEET THE FOLLOWING DESIGN CRITERIA: 5. CONCRETE MIX TESTING AND DESIGN SHALL MEET THE REQUIREMENTS OF CHAPTER 3 OF ACI 318-19 AND SECTION 1905 OF THE 2022 CBC RESPECTIVELY, AND THESE SPECIFICATIONS. 6. ADMIXTURES SHALL BE REVIEWED BY (EOR). CALCIUM CHLORIDE OR ADDED CHLORIDES ARE NOT PERMITTED. 7. PROVIDE A 3/4 INCH CHAMFER ON EXPOSED CORNERS. 8. CONCRETE CURING SHALL BE PER THE PROVISIONS OF THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE OF THE AMERICAN CONCRETE INSTITUTE. 9. ALL CONCRETE SHALL BE CONSOLIDATED WITH MECHANICAL VIBRATORS. 10. ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 GRADE 36 WITH STANDARD NUTS AND WASHERS BETWEEN ANCHOR POINTS. 11. PROVIDE 1/4" PER FOOT SLOPE AT TOP OF FOUNDATION TO DRAIN AWAY FROM EQUIPMENT. REINFORCING STEEL NOTES: 1. DESIGN, DETAILING, FABRICATION AND PLACEMENT OF STEEL REINFORCEMENT SHALL CONFORM TO THE SPECIFICATIONS AND STANDARDS OF ACI 318-19, TMS 402-13, TMS 602-13, AND AWS D1.4 AS APPLICABLE. 2. BAR REINFORCING SHALL CONFORM TO ASTM A615, GRADE 40 FOR #3 & GRADE60 FOR #4 & LARGER. 3. ALL WELDED REINFORCEMENT SHALL BE GRADE 60 ASTM A706. 4. WELDING OF REINFORCING STEEL SHALL CONFORM TO CHAPTER 3 OF ACI 318-19 AND AWS D1.4. THE CONTRACTOR SHALL PREPARE A WRITTEN WELDING PROCEDURE SPECIFICATION CONFORMING TO THE REQUIREMENTS OF AWS D1.4 FOR EACH WELDED SPLICE. THE PRODUCER OF THE REINFORCING BARS SHALL REPORT THE CHEMICAL COMPOSITION AND CARBON EQUIVALENT OF THE STEEL TO THE CONTRACTOR. 5. ALL REINFORCING STEEL, ANCHOR BOLTS, HOLD-DOWN ANCHORS, DOWELS AND INSERTS SHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE OR GROUT. 6. REINFORCING STEEL SHALL BE PROVIDED WITH THE FOLLOWING AMOUNTS OF CONCRETE COVER UNLESS NOTED OTHERWISE: CONCRETE CAST AGAINST EARTH .................................................................. 3" FORMED CONCRETE EXPOSED TO EARTH OR WEATHER: NO. 5 OR SMALLER BARS ........................................................................ 1-1/2" 7. SPLICES: CONCRETE: SPLICES IN NO. 8 OR SMALLER BARS SHALL BE 45 DIAMETERS. SPLICES IN ADJACENT BARS SHALL BE STAGGERED 5'-0". MASONRY: SPLICES IN NO. 7 OR SMALLER BARS SHALL BE 45 DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. SPLICES IN ADJACENT BARS SHALL BE STAGGERED 2'-0". STRUCTURAL STEEL NOTES: 1. DESIGN, FABRICATION AND ERECTION SHALL CONFORM TO THE SPECIFICATIONS AND STANDARDS OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, AISC MANUAL OF STEEL CONSTRUCTION, 16TH EDITION, AISC 360-16, AISC 341-16 AND AISC 358-18. 2. SUBMIT STEEL SHOP DRAWINGS TO (EOR) FOR REVIEW PRIOR TO FABRICATION. 3. STRUCTURAL STEEL GRADES: A. ANCHOR BOLTS & NUTS .........BOLT: ASTM F1554 GRADE 36.......NUT: ASTM 563A HEX B. MACHINE BOLTS & NUTS .........BOLT: ASTM A307 GRADE A ........NUT: ASTM 563A HEX 4. ALL CONNECTIONS NOT SHOWN SHALL CONFORM TO THE "AISC MANUAL OF STEEL CONSTRUCTION", 16TH EDITION. 5. PLACE NON-FERROUS, NON-SHRINK GROUT (BURKE OR APPROVED EQUAL) UNDER ALL BASE PLATES BEFORE ADDING VERTICAL LOAD. 6. SEE ARCHITECTURAL DRAWINGS FOR NAILER HOLES, WELDED STUDS OR OTHER ITEMS NOT SHOWN IN THESE DRAWINGS. WHERE STEEL IS EMBEDDED IN CONCRETE OR MASONRY, PROVIDE HOLES AS REQUIRED FOR PASSAGE OF CONTINUOUS REINFORCING BARS WHERE INDICATED ON THE DRAWINGS. STRUCTURAL STEEL NOTES: 1. DESIGN, FABRICATION AND ERECTION SHALL CONFORM TO THE SPECIFICATIONS AND STANDARDS OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, AISC MANUAL OF STEEL CONSTRUCTION, 16TH EDITION, AISC 360-16, AISC 341-16 AND AISC 358-16. 2. SUBMIT STEEL SHOP DRAWINGS TO (EOR) FOR REVIEW PRIOR TO FABRICATION. 3. STRUCTURAL STEEL GRADES: A. ANCHOR BOLTS & NUTS ........... BOLT: ASTM F1554 GRADE 36 ........NUT: ASTM 563A HEX B. MACHINE BOLTS & NUTS .......... BOLT: ASTM A307 GRADE A ..........NUT: ASTM 563A HEX 4. ALL CONNECTIONS NOT SHOWN SHALL CONFORM TO THE "AISC MANUAL OF STEEL CONSTRUCTION", 16TH EDITION. 5. PLACE NON-FERROUS, NON-SHRINK GROUT (BURKE OR APPROVED EQUAL) UNDER ALL BASE PLATES BEFORE ADDING VERTICAL LOAD. EXPANSION ANCHORS: 1. ANCHORS SHALL BE INSTALLED IN COMPLIANCE WITHIN THE RECOMMENDED PARAMETERS & MANUFACTURERS PUBLISHED INSTRUCTIONS GIVEN IN THE [ICC-ESR] REPORTS: CONCRETE ANCHORS SHALL BE ONE OF THE FOLLOWING PRODUCTS: HILTI KWIK BOLT TZ2........................................................ ICC ER-4266.........LARR #25701 SIMPSON STRONG-BOLT 2.............................................. ICC ER-3037.........LARR #25891 ITW RED HEAD TRUBOLT+............................................... ICC ER-2427.........LARR #25867 POWERS POWER-STUD+................................................. ICC ER-2818.........LARR #25787 MASONRY ANCHORS SHALL BE ONE OF THE FOLLOWING PRODUCTS: HILTI KWIK BOLT TZ...........................................................ICC ER-1917.........LARR #25701 SIMPSON WEDGE-ALL.......................................................ICC ER-1396.........LARR #24682 2. INSTALLATION: 2.1. USE DEPTH GAUGE OR DRILL SPOT TO ENSURE NO OVER DRILLING. 2.2. CONTRACTOR SHALL NOTIFY (EOR). WHERE REINFORCING STEEL INTERFERES WITH INSTALLATION. (EOR). SHALL CONSULT IN ALTERNATE ATTACHMENTS. 2.3. EXPANSION ANCHORS SHALL BE INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS, INCLUDING BUT NOT LIMITED TO: HOLE DIAMETER, HOLE DEPTH, AND HOLE CLEANING WITH DUST- & OIL-FREE COMPRESSED AIR, PRESCRIBED INSTALLATION TORQUE. ALTERNATIVE PRODUCTS, IF PROPOSED, SHALL BE APPROVED FOR USE IN CRACKED CONCRETE, AND SHALL HAVE A CURRENT ICC-ES ESR REPORT. 2.4. USE OF ZINC-PLATED CARBON STEEL ANCHORS IS LIMITED TO DRY, INTERIOR CONDITIONS. ANCHORS INSTALLED IN EXTERIOR LOCATIONS AND/OR IN DAMP ENVIRONMENTS SHALL BE STAINLESS STEEL. 3. SPECIAL INSPECTION: 3.1. PERIODIC SPECIAL INSPECTION IS REQUIRED IN ACCORDANCE WITH SECTION 1705.1.1 AND TABLE 1705.3 OF THE 2022 CBC FOR THE ESR ALLOWABLE TENSION VALUES LISTED IN ESR REPORTS NOTED ABOVE. SPECIAL INSPECTION/ INSPECTOR REQUIREMENTS (CHAPTER 17, 2022 CBC): 1. THE SPECIAL INSPECTOR SHALL BE EMPLOYED BY THE OWNER PER SECTION 1704.2 OF THE 2022 CBC. 2. THE REPORT(S) PREPARED BY THE SPECIAL INSPECTOR SHALL BE SIGNED BY A LICENSED CALIFORNIA CIVIL ENGINEER AND SHALL BE SUBMITTED TO THE BUILDING OFFICIAL AND (EOR). 3. THE SPECIAL INSPECTION SHALL BE CONTINUOUS DURING THE PERFORMANCE OF THE WORK UNLESS OTHERWISE SPECIFIED. 4. THE SPECIAL INSPECTOR MUST BE CERTIFIED BY THE BUILDING OFFICIAL TO PERFORM THE TYPES OF INSPECTIONS SPECIFIED. SUMMARY OF CONTINUOUS AND PERIODIC SPECIAL INSPECTION: THE CONSTRUCTION INSPECTIONS LISTED ARE IN ADDITION TO THE INSPECTIONS REQUIRED PER SECTION 110 OF THE 2022 CBC. SPECIAL INSPECTION IS NOT A SUBSTITUTE FOR INSPECTION BY THE BUILDING OFFICIAL. SPECIALLY INSPECTED WORK THAT IS INSTALLED OR COVERED WITHOUT THE APPROVAL OF THE BUILDING OFFICIAL AND THE SPECIAL INSPECTOR IS SUBJECT TO REMOVAL OR EXPOSURE. 1. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO INFORM THE SPECIAL INSPECTION AGENCY AT LEAST 24 HOURS PRIOR TO PERFORMING ANY WORK THAT REQUIRES SPECIAL INSPECTION. 2. SEE SPECIAL INSPECTION TABLES BELOW FOR SPECIFIC SPECIAL INSPECTION REQUIREMENTS. FILL IN BOX WHEN REQUIRED VERIFICATION AND INSPECTION TASK SPECIAL INSPECTION TABLE FOR POST INSTALLED CONCRETE ANCHORS (1705.3): PERIODICCONTINUOUS 1. INSPECTION OF ANCHORS INSTALLED INTO HARDENED CONCRETE: A. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY INCLINED ORIENTATION TO RESIST TENSION B. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN PART A C. HOLD-DOWN ANCHOR BOLTS REQUIRED STRUCTURAL SPECIFICATIONS FOUNDATION 2500 psi 5.5 SACKS/ YD 1"4" LOCATION MIN 28 DAY COMP STRENGTH MIN CEMENT MAX AGGREGATE MAX SLUMP E 1 2 3 MB IR PI FDC W W EE E BL BL BL BL BL E E E E FDC IR IR E E E FDC W LS LS LS LS LS LS BUILDING PARKING STRIPES (TYP.) 333 33 2 3 3 4 334 HAND RAIL HAND RAIL BIKE RACK CURB CURB SID E W A L K 333.21' FS 333.22' FS 333.22' FS 333.24' TC 333.23' FS 333.40' TC 333.01' FS 333.72' TC 333.21' FS 333.69' TC 333.18' CE 334.12' BW 333.75' BW 331.57' FS 332.22' FS 332. 8 3 ' F S 332.46' FS 332.82' FS 333.30' BW 333.31' BW 334.03' B W 334.12' BW 333.98' CE 334.14' CE SIDE W A L K MOW STRIP 333.26' FS 332.9 2 ' F S FINISHED FLOOR 334.15' CURB DRAIN 3 3 3 . 2 0 ' T C 3 3 2 . 8 7 ' F S 333.80' TC 333.33' BW 333.79' TC 333.32' BW DUAL EV CHARGER CONTROL TABLE (U.S. SURVEY FEET): PT#NORTHING EASTING ELEV.DESC. 1 1855544.94 6562430.29 332.01 SET SCRIBE X 2 1855528.21 6562472.53 332.15 SET SCRIBE X 3 1855567.82 6562449.56 333.11 SET SCRIBE X SURVEY NOTES: 1.THE UNDERGROUND UTILITIES SHOWN HEREON HAVE BEEN LOCATED FROM UTILITY MARK OUTS PROVIDED BY AIRX UTILITY SURVEYORS ON JUNE 21, 2023. THE CERTIFYING SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE CERTIFYING SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE. THE CERTIFYING SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. 2.ELEVATIONS SHOWN HEREON WERE DERIVED FROM CONVENTIONAL OBSERVATIONS WITH A RELATIVE ACCURACY OF ±0.05'. SURVEYOR'S CERTIFICATION: THIS TOPOGRAPHIC MAP WAS PREPARED BY ME OR UNDER MY DIRECTION AND IS BASED UPON A FIELD SURVEY COMPLETED ON JUNE 22, 2023. DATED: JUNE 27, 2023 _________________________________________ CRAIG D. WILSON LS 7142 EXPIRES: 12/31/24 CONAWAY GEOMATICS CRAIG D. WILSON No. 7142 BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS MAP IS THE INTERNATIONAL TERRESTRIAL REFERENCE FRAME 2014 (ITRF2014), DERIVED FROM THE TRIMBLE RTX (REAL TIME EXTENDED) SOLUTION, ADJUSTED TO THE 2023.47 EPOCH, NAD 83, ZONE 5. COORDINATES SHOWN HEREON ARE GRID VALUES. USE THE FOLLOWING LOCAL SITE VALUES TO OBTAIN GROUND VALUES: ·LOCAL SITE -LAT: 34°05'28.056052"N LON: 117°59'50.920414"W E HGT: 219.59 FT FT GSF:1.0000225287 ELEVATIONS SHOWN HEREON ARE EXPRESSED IN US SURVEY FEET, BASED ON THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88), AND ARE DERIVED FROM GPS OBSERVATIONS PER THE ADJUSTMENT SHOWN ABOVE. 0 40202010 SCALE: 1" = 20' Z:\23.72BME001.51-SamuelSonandCO\Drawings\23.72BME-BASE.dwg, 6/27/2023 10:33 AM, JVillasenor CONAWAYGEO.COM PH: (714) 486-0258 OF SHT NO.:BY REVISIONS DESCRIPTION DATE DATE: NO. DRAWN BY; SCALE: CHECKED BY: PROJECT NO: 1 2 3 4 5 6 SAMUEL SON AND CO BRYTEMOVE ENERGY TOPOGRAPHIC SURVEY 23.72BME JV CW 1" = 20' 1 1 ------------ ------------ ------------ ------------ ------------ ------------ 06/27/2023 LINE LEGEND LINE DESCRIPTION ELECTRIC UNDERGROUNDE SYMBOL LEGEND SYMBOL DESCRIPTION BOLLARD HORIZONTAL & VERTICAL CONTROL POINT DECIDUOUS TREE ELECTRIC AREA LIGHT ELECTRIC RISER ELECTRIC VAULT IRRIGATION BOX IRRIGATION VALVE MAILBOX ELECTRIC VEHICLE CHARGING STATION SIGN WATER FIRE DEPARTMENT CONNECTION WATER POST INDICATOR VALVE WATER VALVE BL E E IR IR MB FDC PI W ABBREVIATION LEGEND FS FINISHED SURFACE CE CONCRETE EDGE TC TOP OF CURB BW BACK OF WALK LS LANDSCAPING 12389 LOWER AZUSA ROAD ARCADIA, CA EVSE EVSE EVSE EVSE EVSE EVSE EVSE EVSE T 33 2 . 8 3 ' F S 2 3 IR PI FD C W W EEE E E EE FD C IR IR E E E FD C W 332 UE NO PAR K I N G EVSE EVSE T SHEET NUMBER SHEET TITLE DATE: SCALE: CHECKED BY: DRAWN BY: REVISION MARK DATE DESCRIPTION PROJECT DEVELOPER PROJECT SITE BRYTEMOVE ENERGY 12 MORGAN IRVINE, CA 92618 TEL: (714) 908-5266 www.brytemove.com V1 11/10/23 CDIFP AS SHOWN 03/22/2024 E-1 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL:(800) 655-4555 RW DLH SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 DWG: C:\Users\DeDe\AppData\Local\Temp\AcPublish_6920\SCE-SAMUEL, SON & CO_AHJ CORRECTIONS_20240116.dwg BY: DeDe Mar 25, 2024 - 8:11:34amPROJ:P- A 01/16/24 AHJ CORRECTIONS B 03/22/24 AHJ CORRECTIONS PLOT PLAN PLOT PLAN Feet 0 30 60 (E) 300kVA UTILITY TRANSFORMER (N) "EV - L1" DISTRIBUTION PANEL (N) 112.5kVA STEPDOWN TRANSFORMER 480 - 120/208V, 3PH, 4W (N) MSB (N) TEMPORARY SINGLE PORT TERMINAL BLOCK #3 (N) TEMPORARY SINGLE PORT TERMINAL BLOCK #2 (N) TEMPORARY SINGLE PORT TERMINAL BLOCK #1 (N) TEMPORARY DUAL PORT TERMINAL BLOCK #7 (N) TEMPORARY DUAL PORT TERMINAL BLOCK #6 (N) TEMPORARY DUAL PORT TERMINAL BLOCK #5 (N) TEMPORARY DUAL PORT TERMINAL BLOCK #1 (N) TEMPORARY DUAL PORT TERMINAL BLOCK #2 (N) TEMPORARY DUAL PORT TERMINAL BLOCK #3 (N) TEMPORARY DUAL PORT TERMINAL BLOCK #4 APPROXIMATE PROPERTY LINE LOWER AZUSA ROAD EV SE EV SE EV SE EV SE EV SE EV SE EV SE EV SE T 332.83' FS E E E 2 3IRPI FDC W W EE E E E E E FDC IR IR E E E FDC W 332 UE UE UE UE NO PARKING EV SE EVSE UE UE UE T SHEET NUMBER SHEET TITLE DATE: SCALE: CHECKED BY: DRAWN BY: REVISION MARK DATE DESCRIPTION PROJECT DEVELOPER PROJECT SITE BRYTEMOVE ENERGY 12 MORGAN IRVINE, CA 92618 TEL: (714) 908-5266 www.brytemove.com V1 11/10/23 CDIFP AS SHOWN 03/22/2024 E-1.1 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL:(800) 655-4555 RW DLH SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 DWG: C:\Users\DeDe\AppData\Local\Temp\AcPublish_6920\SCE-SAMUEL, SON & CO_AHJ CORRECTIONS_20240116.dwg BY: DeDe Mar 25, 2024 - 8:11:35amPROJ:P- A 01/16/24 AHJ CORRECTIONS B 03/22/24 AHJ CORRECTIONS SITE PLAN SITE PLAN Feet 0 10 20 SCE ELECTRICAL SERVICE SUPPLY TO METER, BY T&D UE PROPOSED NON EXPOSED ELECTRICAL CONDUIT PROPOSED DUAL PORT TERMINAL BLOCK E V S E PROPOSED BOLLARD (N) FLARED CONCRETE LEGEND: (N) WHEEL STOP (E) UTILITY TRANSFORMERT (N) STEP DOWN TRANSFORMER PROPOSED SINGLE PORT TERMINAL BLOCK E V S E T NOTES: 1.UTILITY DISTRIBUTION INFRASTRUCTURE TO BE BUILT BY OTHERS AND SHOWN ONLY FOR PROJECT CLARITY AND COORDINATION. 2.IMPACTED EXISTING PARKING = 18 TOTAL SPACES. 3.PROPOSED CHARGING = 17 TOTAL. 4.EVSE LAYOUT BASED ON USE OF DUAL AND SINGLE PORT CHARGERS 5.ALL PARKING SPACES ARE EXISTING. FIELD TO VERIFY EXACT DIMENSION PRIOR TO CONSTRUCTION. 6.FIELD VERIFY ALL EQUIPMENT LOCATION TO MAKE SURE APPROPRIATE SPACE IS AVAILABLE. 7.FIELD VERIFY ALL EXISTING UTILITY LOCATIONS FOR EASEMENT REQUIREMENT. 8.ADA STALLS TO BE EXTENDED 2' TO MAINTAIN <2% IN ALL DIRECTIONS 9.USE THE DOWEL CONSTRUCTION JOINT TYPE TO SET NEW HOUSEKEEPING PADS NEXT TO EXISTING CONCRETE PADS. 10.PER CBC 11B-705.2.2.2.1 EXCEPTION 1 REDUCE WIDTH OF DETECTABLE WARNINGS TO 24 INCHES WIDE TO ALLOW FOR PEDESTRIAN TRAVEL WITHOUT DETECTABLE WARNINGS IN DIRECTION OF SIDEWALK (N) "EV-MSB" (SEE NOTE 9) (E) SCE UTILITY TRANSFORMER P563123 -277/480V 3P 300KVA PAD MOUNTED (N) DUAL TERMINAL BLOCK #2 (N) 12' MIN. VAN ACCESSIBLE EV STALL (N) 9' MIN. STANDARD EV STALL (N) 5' MIN. ACCESS AISLE (E) 2% MAX SLOPE ALL DIRECTIONS (N) STEP-DOWN TRANSFORMER (N) DUAL TERMINAL BLOCK #4 (N) DUAL TERMINAL BLOCK #6 (N) SINGLE TERMINAL BLOCK #1 (N) DUAL TERMINAL BLOCK #1 (N) DUAL TERMINAL BLOCK #3 (N) DUAL TERMINAL BLOCK #5 (N) DUAL TERMINAL BLOCK #7 (N) SINGLE TERMINAL BLOCK #3 (N) SINGLE TERMINAL BLOCK #2 18 ' - 1 " T Y P . 5'12'9' (E) TRUNCATED DOME 3' - 9 " TY P . (E) CURB (E) PATH OF TRAVEL (N) METER MAIN SWITCHBOARD (N) DISTRIBUTION PANEL (N) "EV - L1" (SEE NOTE 9) 2' 9' SEE NOTE 8 9'9'9'9'9'9'9'8'-9"9'9'9'9'9'9'-2" 1 E-3 2 E-3 17 ' 17 ' 4' - 1 " LS LS LS RAMP UPSIDEWALKSIDEWALK 3' - 3 " 9'-5"7'-7"9'-4" SIDEWALK SI D E W A L K SI D E W A L K 19 ' - 2 " B A A A A A A BOTTOM OF RAMP REMOVE EXISTING TRUNCATED DOMES 6' PER CBC 11B-405.7.3.1 6' 2.5' X 4' CLEAR FLOOR SPACE 2' - 6 " 4'4' A SEE NOTE 10 B B B 332. 8 3 ' F S E E E 2 3 IR PI FDC W W EE E E E E E FDC IR IR E E E FDC W 3 3 2 T SHEET NUMBER SHEET TITLE DATE: SCALE: CHECKED BY: DRAWN BY: REVISION MARK DATE DESCRIPTION PROJECT DEVELOPER PROJECT SITE BRYTEMOVE ENERGY 12 MORGAN IRVINE, CA 92618 TEL: (714) 908-5266 www.brytemove.com V1 11/10/23 CDIFP AS SHOWN 03/22/2024 E-2 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL:(800) 655-4555 RW DLH SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 DWG: C:\Users\DeDe\AppData\Local\Temp\AcPublish_6920\SCE-SAMUEL, SON & CO_AHJ CORRECTIONS_20240116.dwg BY: DeDe Mar 25, 2024 - 8:11:35amPROJ:P- A 01/16/24 AHJ CORRECTIONS B 03/22/24 AHJ CORRECTIONS DEMOLITION PLAN 1 DEMOLITION PLAN DEMOLITION KEYNOTES AND LEGEND 1.CLEAR AND GRUB EXISTING LANDSCAPE AREA AS SHOWN ON THE DRAWINGS. LEVEL AREA TO MATCH EXISTING STEP/PAD 2.EXISTING CONCRETE TO BE REMOVED. 3.CONCRETE SLAB TO BE REMOVED 4.EXISTING STRIPING TO BE REMOVED 5.EXISTING EV CHARGER TO BE REMOVED 6.REMOVE DETECTABLE WARNINGS 30" X 48" IN FRONT OF NEW CHARGERS FOR CLEAR LANDING IN FRONT OF ACCESSIBLE EV CHARGERS 7.REMOVE DETECTABLE WARNINGS 72" X 39" AT BOTTOM OF RAMP 8.REMOVE 1' OF DETECTABLE WARNINGS ALONG EXISTING PATH OF TRAVEL TO ALLOW PEDESTRIAN TRAVEL IN THE DIRECTION OF THE SIDEWALK WITHOUT TRAVELING OVER THE DETECTABLE WARNINGS EXISTING LANDSCAPE/PLANTER TO BE REMOVED EXISTING CONCRETE TO BE REMOVED 1 4 4 5 3 2 1 1 1 1 1 26 6 6 EXISTING DETECTABLE WARNINGS TO BE REMOVED B B B EV SE EV SE EV SE EV SE EV SE EV SE EV SE EV SE T E UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE T 3IR PI NO PARKING EV SE EVSE SHEET NUMBER SHEET TITLE DATE: SCALE: CHECKED BY: DRAWN BY: REVISION MARK DATE DESCRIPTION PROJECT DEVELOPER PROJECT SITE BRYTEMOVE ENERGY 12 MORGAN IRVINE, CA 92618 TEL: (714) 908-5266 www.brytemove.com V1 11/10/23 CDIFP AS SHOWN 03/22/2024 E-3 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL:(800) 655-4555 RW DLH SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 DWG: C:\Users\DeDe\AppData\Local\Temp\AcPublish_6920\SCE-SAMUEL, SON & CO_AHJ CORRECTIONS_20240116.dwg BY: DeDe Mar 25, 2024 - 8:11:37amPROJ:P- A 01/16/24 AHJ CORRECTIONS B 03/22/24 AHJ CORRECTIONS LAYOUT DETAIL 3 LAYOUT DETAIL (N) 9' MIN. STANDARD EV STALL (N) 5' MIN. ACCESS AISLE (N) 2% MAX SLOPE ALL DIRECTIONS 7 TYP. 3 CUSTOMER INFRASTRUCTURE IMPROVEMENT # 1 (N) "EV-MSB" 2 (N) 112.5kVA STEP-DOWN TRANSFORMER 4 (N) INSTALL TEMPORARY DUAL TERMINAL BLOCK FOR FUTURE CHARGER 5 (N) INSTALL TEMPORARY SINGLE TERMINAL BLOCK FOR FUTURE CHARGER 6 (N) 4"Ø POUR-IN-BOLLARD 7 (N) WHEEL STOP 8 (N) VERTICAL SIGNAGE 9 (N) RE-STRIPPING 10 (N) INSTALL CONCRETE PAD FOR EQUIPMENT (USE DOWEL CONSTRUCTION JOINT) 11 (N) INSTALL 5/8" X 8' GROUND ROD 12 24" WIDE TRENCH EXISTING RAMP UP 20 ' 12'5'9' 855 7 7 3' 9 9 99 1 LAYOUT DETAIL 3 (N) DISTRIBUTION PANEL "EV - L1" (N) 12' MIN. VAN ACCESSIBLE EV STALL 8 18'18'18' 69'-3" 1'-5" 1' - 4 " 6" 10 " 2' - 1 0 " 2' - 3 " 2' - 8 " 2' - 1 0 " 27'-2"18'18'13'-6"11'-1" 121212 12 12 12 3' 1 2 11 11 11 544 4 444 4 7 TYP. (N) 2' EXTENSION TO EXISTING STALL LENGTH 14'-9"10'-6" 6 12 ' - 2 " 10 10 10 " 4' - 1 1 " 3' - 8 " 5'-6" 5'-4" (E) TRUNCATED DOME EXISTING CURB EXISTING SIDEWALK/TRUNCATED DOMES EXISTING SIDEWALK/ TRUNCATED DOMES 3' - 3 " 11 " 4' - 1 " EXISTING SIDEWALK EX I S T I N G S I D E W A L K 9'-5"7'-7"9'-4" SCALE:2 TRUNCATED DOME NTS .2 " .6 5 " M I N . 2. 3 " - 2 . 4 " 2.3" - 2.4" .45"Ø - .47"Ø TOP .9"Ø - .92"Ø BASE (E) ZERO CURB (E) ZERO CURB FRONT ENTRANCE EX I S T I N G S I D E W A L K A A A BBB B SHEET NUMBER SHEET TITLE DATE: SCALE: CHECKED BY: DRAWN BY: REVISION MARK DATE DESCRIPTION PROJECT DEVELOPER PROJECT SITE BRYTEMOVE ENERGY 12 MORGAN IRVINE, CA 92618 TEL: (714) 908-5266 www.brytemove.com V1 11/10/23 CDIFP AS SHOWN 03/22/2024 E-3.1 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL:(800) 655-4555 RW DLH SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 DWG: C:\Users\DeDe\AppData\Local\Temp\AcPublish_6920\SCE-SAMUEL, SON & CO_AHJ CORRECTIONS_20240116.dwg BY: DeDe Mar 25, 2024 - 8:11:38amPROJ:P- A 01/16/24 AHJ CORRECTIONS B 03/22/24 AHJ CORRECTIONS ELEVATIONS AND DETAILS (N) TERMINAL BLOCK (N) "EV MSB" R18 " S W E E P R 1 8 " S W E E P R4 8 " S W E E P R 3 ' - 8 " SEE STRUCTURAL FOR FOUNDATION DETAILSEE STRUCTURAL FOR CONCRETE PAD DETAIL NOTES: - SIGN MUST BE PLACED WITHIN THE PROJECTED HEAD OF PARKING STALL. - BOLLARD TO BE USE IF SUBJECT TO DAMAGE. - 60" MIN. - LANDSCAPE OR WALL MOUNTED. 80" MIN. - FREE STANDING IN ACCESSIBLE ROUTE. SCALE:1 VERTICAL SIGNAGE NTS 12" 12 "7" 4" 6' - 8 " M I N . C L E A R 4" 3' M I N . 8" GALV. STEEL POST CAP ADD VAN SIGN WHEN SHOWN ON PLANS, BLUE FIELD, 1/2" WHITE BORDER, AND 1" WHITE LETTERS, ALL OF REFLECTIVE SHEETING. SEE NOTE BELOW. 18 GA STEEL WITH FIELD OF BLUE, 1/2" WHITE BORDER, AND WHITE ACCESSIBLE SYMBOL, ALL OF REFLECTIVE SHEETING. 2" SCH 40 GALV STEEL POST FINISHED CONCRETE OR GROUND SURFACE CONCRETE FASTENER: 1/4" DIA. HEX. BOLT W/ LOCK WASHER 1-1/2" FROM TOP AND BOTTOM OF SIGN. 1' 1' - 6 " 7" 5' M I N . O R 6 ' - 8 " M I N . SE E N O T E S 5' M I N . O R 6 ' - 8 " M I N . SE E N O T E S 1' 1' - 6 " FINISH GRADEFINISH GRADE 2 -- 2 -- SCALE:2 VERTICAL SIGNAGE DETAILS NTS SCALE:3 EQUIPMENT ELEVATION NTS SCALE:4 WHEEL STOP DETAIL NTS SHEET NUMBER SHEET TITLE DATE: SCALE: CHECKED BY: DRAWN BY: REVISION MARK DATE DESCRIPTION PROJECT DEVELOPER PROJECT SITE BRYTEMOVE ENERGY 12 MORGAN IRVINE, CA 92618 TEL: (714) 908-5266 www.brytemove.com V1 11/10/23 CDIFP AS SHOWN 03/22/2024 E-3.2 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL:(800) 655-4555 RW DLH SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 DWG: C:\Users\DeDe\AppData\Local\Temp\AcPublish_6920\SCE-SAMUEL, SON & CO_AHJ CORRECTIONS_20240116.dwg BY: DeDe Mar 25, 2024 - 8:11:38amPROJ:P- A 01/16/24 AHJ CORRECTIONS B 03/22/24 AHJ CORRECTIONS ELEVATIONS AND DETAILS BILL OF MATERIALS (1 UNIT) REFERENCE NUMBER ITEM QUANTITY 1 VYNKIER VM554 ENCLOSURE 1 EA 2 VYNCKIER BACKING FLATE VMBP55A 1 EA 3 TERMINAL BLOCK BUSSMANN 1400A-6, 90A, #4-14 AWG CU,600 VAC 1 EA 4 EATON B-LINE B22SH120 HDC, 120A 10' LENGTHS 1 EA 5 B-LINE 1/4 X 1.25" 20 HHCS ZINC 2 EA 6 B-LINE SPRING NUT, N224, 1/4 - 20 2 EA 7 UV STABILIZED NYLON CABLE TIES (1/4" WIDTH)5 EA NOTES: 1.TERMINAL BLOCK AND TEMPORARY SUPPORT WILL BE REMOVED ONCE CHARGERS ARE INSTALLED. 2.SECURELY FASTEN PVC CONDUIT TO CONDUIT SUPPORT WITHJ 1/884" WIDE UV STABILIZED NYLON CABLE TIES. PROVIDE 1 TIE EVERY 12". 3.PARTS INCLUDED IN THE BILL OF MATERIALS ARE FOR 1 TEMPORARY TERMINAL BLOCK ONLY. SEE ELECTRICAL CONDUIT PLAN FOR LOCATION AND COUNT. #4 BARS @ 10" MAX OC BOTH WAYS, CENTERED IN PAD POWER-STUD SD4, 5/8" DIA W/ MIN EFF EMBED OF 2.75", (4) ANCHORS PER CHARGER FINISHED GRADE 321 5 6 7 4 CONCRETE PAD 1' ( T Y P ) PVC ELECTRICAL CONDUIT RISER 6' ( M I N ) 1' - 6 " ( M I N ) 3.5" CLR MIN 2" M A X 8" 3. 5 " C L R M I N 4 SECTION A-A: 1'-2" 2'-3" 1' - 2 " 2' - 3 " SINGLE & DUAL EV CHARGER PVC ELECTRICAL CONDUIT RISER SCALE:1 TERMINAL BLOCK DETAILS NTS 3' - 6 " 2' M I N . 1'-6"Ø 1' - 6 " M I N . CONCRETE CAP 4"Ø SCH 80 PIPE SCALE:2 BOLLARD DETAIL NTS SCALE:3 PAD DETAIL NTS PER PLAN 8" 3" M A X 3" CLR 3" C L R A - A A -- A -- PER PLAN PE R E Q U I P M E N T S P E C PER EQUIPMENT SPEC PE R E Q U I P M E N T S P E C PER EQUIPMENT SPEC 3 MIN' 3' MIN. 4" MIN HILTI, 3/8 DIA. MIN 1.5" MIN. EFFECTIVE EMEBEDMENT MINIMUM 6 BARS #4 BARS @ 12" OC BOTH WAYS, CENTERED IN PAD (N) CONCRETE SLAB(N) CONCRETE SLAB (E) CONCRETE SLAB4" MI N 4'' EMBEDMENT MIN. 6" MIN DRILL AND EPOXY BOND #4 18'' DOWEL @ 2'' OC MAX WITH SIMPSON EPOXY TIE ADHESIVE ALIGN 4" A A A A 3 PI 332 NO PARKING EV SE EVSE SHEET NUMBER SHEET TITLE DATE: SCALE: CHECKED BY: DRAWN BY: REVISION MARK DATE DESCRIPTION PROJECT DEVELOPER PROJECT SITE BRYTEMOVE ENERGY 12 MORGAN IRVINE, CA 92618 TEL: (714) 908-5266 www.brytemove.com V1 11/10/23 CDIFP AS SHOWN 03/22/2024 E-4 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL:(800) 655-4555 RW DLH SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 DWG: C:\Users\DeDe\AppData\Local\Temp\AcPublish_6920\SCE-SAMUEL, SON & CO_AHJ CORRECTIONS_20240116.dwg BY: DeDe Mar 25, 2024 - 8:11:39amPROJ:P- A 01/16/24 AHJ CORRECTIONS B 03/22/24 AHJ CORRECTIONS ACCESSIBILITY SCALE:2 TRUNCATED DOME NTS 2'-3" 45° .1 8 " - . 2 2 " .6 5 " M I N . 2. 3 " - 2 . 4 " 2.3" - 2.4" .45"Ø - .47"Ø TOP .9"Ø - .92"Ø BASE 4" WHITE STRIPE ON ASPHALT, YELLOW ON CONCRETE, AND BLUE IN ADA AREAS SCALE:3 TRANSVERSE STRIPING NTS (E) 2% MAX SLOPE ALL DIRECTIONS 1 ASSESSIBLE ROUTE DETAIL Feet 0 2 4 REMOVE DETECTABLE WARNINGS AT BOTTOM OF RAMP TO CREATE A 6' X 3' TURNING SPACE PER (N) 2' EXTENSION TO EXISTING STALL LENGTH REDUCE DETECTABLE WARNINGS TO 24 INCHES PER CBC 11B-705.1.2.2.2.1 EXCEPTION 1 REMOVE DETECTABLE WARNINGS 30" X 48" IN FRONT OF EV CHARGER TO MAIINTAIN CLEAR FLOOR SPACE PER CBC 11B-305.2 2' 1' - 3 " 20 ' 12'5'9' 4' 2' - 6 " 3' - 3 " 6' RAMP UP B 200 AF 175 AT 3P U G P S M GND SECTION 1 UTILITY PULL SECTION METER MAIN 277/480V SECTION SECTION 2 (2) 5/8" Ø X 8' CU GR 6' APART (N) (1) #4 AWG GEC PER NEC 250.66 (N) DUAL TERMINAL BLOCK #7 T (E) UTILITY TRANSFORMER 400 AF 400 AT 3P (N) METER MAIN SWITCHBOARD "EV-MSB" 200 AMP, 277/480 VOLT, 3PH, 4W, NEMA 3R, 42KAIC, EUSERC (N) #2/0 AWG CU GEC (2) 5/8" x 8' CU GR 6' APART (N) 112.5kVA TRANSFORMER 480V-120/208V 40 AF 40 AT 2P 40 AF 40 AT 2P 40 AF 40 AT 2P 40 AF 40 AT 2P (N) DUAL TERMINAL BLOCK #1 20 AF 20 AT 1P (N) SINGLE TERMINAL BLOCK #1 40 AF 40 AT 2P 40 AF 40 AT 2P (N) DISTRIBUTION PANEL "EV - L1" 400 AMP, 120/208 VOLT, 3PH, 4W NEMA 3R 42KAIC 40 AF 40 AT 2P (N) SINGLE TERMINAL BLOCK #2 (N) SINGLE TERMINAL BLOCK #3 THRU (F) GATEWAY SHEET NUMBER SHEET TITLE DATE: SCALE: CHECKED BY: DRAWN BY: REVISION MARK DATE DESCRIPTION PROJECT DEVELOPER PROJECT SITE BRYTEMOVE ENERGY 12 MORGAN IRVINE, CA 92618 TEL: (714) 908-5266 www.brytemove.com V1 11/10/23 CDIFP AS SHOWN 03/22/2024 E-5 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL:(800) 655-4555 RW DLH SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 DWG: C:\Users\DeDe\AppData\Local\Temp\AcPublish_6920\SCE-SAMUEL, SON & CO_AHJ CORRECTIONS_20240116.dwg BY: DeDe Mar 25, 2024 - 8:11:39amPROJ:P- A 01/16/24 AHJ CORRECTIONS B 03/22/24 AHJ CORRECTIONS SINGLE LINE DIAGRAM PANEL LOAD SCHEDULES CONDUIT & WIRE SCHEDULE NOTES: 1.ALL FUTURE EV CHARGERS SHALL BE DESIGNED BY OTHERS UNDER SEPARATE PERMIT(S). 2.DESIGN ASSUMES NO ADDITIONAL LOADS WILL BE ADDED 3.ALL OCPD TO HAVE A MINIMUM 75 DEGREE TERMINATION LUG RATING 4 CONDUIT AND WIRE SCHEDULE 1 SINGLE LINE DIAGRAM 2 PANEL SCHEDULE METER MAIN SWITCHBOARD "EV-MSB" A D CONDUIT & WIRE SCHEDULE IDENTIFIER FROM TO VOLTAGE (VAC - PHASE) NET CURRENT (AMPS) UPSTREAM OCPD (AMPS) CONDUIT SIZE/TYPE WIRE CONTENTS MAX. ONE WAY DISTANCE (FEET) VOLTAGE DROP %REMARKS A (E) UTILITY TRANSFORMER (N) METER MAIN SWITCHBOARD "EV-MSB" (277/480V SECTION) 277/480V - 3Ø 135 200 REFER TO UTILITY DRAWING REFER TO UTILITY DRAWING --- B (N) METER MAINSWITCHBOARD "EV-MSB" (277/480V SECTION) (N) 112.5kVA STEP-DOWN TRANSFORMER 480V - 3Ø 135 175 2 1/2"C SCH 40 PCV (3) 4/O AWG THWN-2 CU (1) #6 AWG EGC CU 17 0.05 0-643 FT MAX C (N) 112.5kVA STEP-DOWN TRANSFORMER (N) DISTRIBUTION PANEL "EV - L1" (120/208V SECTION) 120/208V - 3Ø 312 400 PARALLEL RUN (2) 2 1/2"C SCH 40 PCV (4) 4/O AWG THWN-2 CU (1) #2 AWG SSBJ CU 17 0.14 PARALLEL RUN D (N) DISTRIBUTION PANEL "EV - L1" (120/208V SECTION) (N) DUAL TERMINAL BLOCK #1 - #7 208V - 1Ø 30 40 1"C SCH 40 PCV/RMC (4) #8 AWG THWN-2 CU (1) #10 AWG EGC CU 89 2.01 0133 FT MAX E (N) DISTRIBUTION PANEL "EV - L1" (120/208V SECTION) (N) SINGLE TERMINAL BLOCK #1 208V - 1Ø 30 40 1"C SCH 40 PCV/RMC (2) #8 AWG THWN-2 CU (1) #10 AWG EGC CU 106 2.39 0-133 FT MAX F (N) DISTRIBUTION PANEL "EV - L1" (120/208V SECTION) (N) SINGLE TERMINAL BLOCK #2 & #3 208V - 1Ø 30 40 1"C SCH 40 PCV/RMC (2) #6 AWG THWN-2 CU (1) #8 AWG EGC CU 143 2.03 134-212 FT MAX G (N) DISTRIBUTION PANEL "EV - L1" (120/208V SECTION) (N) GATEWAY EVG-CMSN-DC-AC 120V - 1Ø 16 20 1"C SCH 40 PCV/RMC (2) #10 AWG THWN-2 CU (1) #10 AWG EGC CU 3 PANEL SCHEDULE DISTRIBUTION PANEL "EV - L1" B C D E F F G EV SE EV SE EV SE EV SE EV SE EV SE EV SE EV SE T E E E 2 3IRPI FDC W W EE E E E E E FDC IR IR E E E FDC W 332 UE UE UE UE NO PARKING EV SE EVSE UE UE UE T SHEET NUMBER SHEET TITLE DATE: SCALE: CHECKED BY: DRAWN BY: REVISION MARK DATE DESCRIPTION PROJECT DEVELOPER PROJECT SITE BRYTEMOVE ENERGY 12 MORGAN IRVINE, CA 92618 TEL: (714) 908-5266 www.brytemove.com V1 11/10/23 CDIFP AS SHOWN 03/22/2024 E-5.1 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL:(800) 655-4555 RW DLH SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 DWG: C:\Users\DeDe\AppData\Local\Temp\AcPublish_6920\SCE-SAMUEL, SON & CO_AHJ CORRECTIONS_20240116.dwg BY: DeDe Mar 25, 2024 - 8:11:40amPROJ:P- A 01/16/24 AHJ CORRECTIONS B 03/22/24 AHJ CORRECTIONS TRENCH RUN AND DETAIL TRENCH RUN Feet 0 10 20 2 -- 2 -- 2 -- NATIVE SOIL BACKFILL / NEW ASPHALT / NEW CONCRETE SLURRY OR 90% COMPACT BACKFILL WHERE APPLICABLE1" 24 " M I N . VERIFY CONDUIT TYPE, SIZE, AND QUANTITY WITH "CONDUIT AND WIRE SCHEDULE" TABLE ON SHEET E-5 NOTE: - DETECTABLE WARNING TAPE TO BE INSTALL THROUGHOUT THE LENGTH OF TRENCH. SCALE:2 TRENCH DETAIL NTS MOVE BACK 4' TO LEFT MOVE BACK 4' TO RIGHT SHEET NUMBER SHEET TITLE DATE: SCALE: CHECKED BY: DRAWN BY: REVISION MARK DATE DESCRIPTION PROJECT DEVELOPER PROJECT SITE BRYTEMOVE ENERGY 12 MORGAN IRVINE, CA 92618 TEL: (714) 908-5266 www.brytemove.com V1 11/10/23 CDIFP AS SHOWN 03/22/2024 E-6 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL:(800) 655-4555 RW DLH SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 DWG: C:\Users\DeDe\AppData\Local\Temp\AcPublish_6920\SCE-SAMUEL, SON & CO_AHJ CORRECTIONS_20240116.dwg BY: DeDe Mar 25, 2024 - 8:11:41amPROJ:P- A 01/16/24 AHJ CORRECTIONS B 03/22/24 AHJ CORRECTIONS SPECIFICATION SHEET ” ” · · · · · · · · · · · · · · · · SHEET NUMBER SHEET TITLE DATE: SCALE: CHECKED BY: DRAWN BY: REVISION MARK DATE DESCRIPTION PROJECT DEVELOPER PROJECT SITE 0 10/20/23 FOR REVIEW AS SHOWN 10/20/2023 S-1 LM MK BRYTEMOVE ENERGY 12 MORGAN IRVINE, CA 92618 TEL: (714) 908-5266 www.brytemove.com SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL:(800) 655-4555 SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 GENERAL NOTES 10/20/23 SHEET NUMBER SHEET TITLE DATE: SCALE: CHECKED BY: DRAWN BY: REVISION MARK DATE DESCRIPTION PROJECT DEVELOPER PROJECT SITE 0 10/20/23 FOR REVIEW AS SHOWN 10/20/2023 S-2 LM MK BRYTEMOVE ENERGY 12 MORGAN IRVINE, CA 92618 TEL: (714) 908-5266 www.brytemove.com SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL:(800) 655-4555 SAMUEL, SON & CO LCC 12389 LOWER AZUSA RD. ARCADIA, CA 91006 SCE PROJECT ID: 00001402409 CONCRETE PAD DESIGN 10/20/23