HomeMy WebLinkAbout400 S Baldwin Ave - 2024 - Nordstroms Stock Shelving RacksBayley Construction, LP 23101 Lake Center Drive, Suite 200 Lake Forest, California 92630 P: (714) 540-8863 Project: 23287 Nordstrom Santa Anita 345 Remodel 400 S Baldwin Avenue Arcadia, California 91007     Submittal #105600-2.1 - Storage Assembly Layout 105600 - Storage Assemblies   Revision 1 Submittal Manager Ryan Canary (Bayley Construction, LP) Status Open Date Created Mar 19, 2024 Issue Date Mar 19, 2024 Spec Section 105600 - Storage Assemblies Responsible Contractor Associates Material Handling Received From Stephen Bell (Associates Material Handling) Received Date  Submit By   Final Due Date Apr 9, 2024 Lead Time Cost Code Location Type Shop Drawing Approvers Ryan Canary (Bayley Construction, LP), Stefanie Means (CallisonRTKL, Inc.) Ball in Court Stefanie Means (CallisonRTKL, Inc.) Distribution Description     Submittal Workflow Name Sent Date Due Date Returned Date Response Attachments General Information Attachments      Stephen Bell  Mar 26, 2024 Mar 21, 2024 Submitted 031-105600-02_R1 Storage Assembly Layout.pdf   Ryan Canary Mar 21, 2024 Apr 2, 2024 Mar 21, 2024 Approved Stefanie Means Mar 21, 2024 Apr 9, 2024  Pending     Bayley Construction, LP Page 1 of 1 Printed On: Mar 21, 2024 08:16 AM PDT    LIST OF DRAWINGS/DRAWING INDEX DRAWING NAME ISSUE DATE VICINITY AND SITE MAP, & GENERAL INFORMATION SHEET L0 SECOND FLOOR SHELVING LAYOUT (STOCK 2106)L1 FOOT PLATE MAP (STOCK 2106)L1.1 GENERAL NOTES: SEISMIC DATA: Ss = 2.018 S1 = 0.721 Sds = 1.614 Sd1 = 0.817 Vt = 0.512 (2ND FLOOR) Seismic Design Category = D Soil Site Class = D (Assumed) Importance Factor = 1.0 D1 PROJECT DIRECTORY: OWNER NORDSTROM, INC. 1600 7TH AVE, SUITE 2500 SEATTLE, WA 98101 CONTACT: DAVID PEREGOY PHONE: (206) 303-6551 GENERAL CONTRACTOR BAYLEY CONSTRUCTION 23101 LAKE CENTER DRIVE, SUITE 200 SEATTLE, WA 98101 CONTACT: MARK FLORER PHONE: (714) 540-8863 ELECTRICAL ENGINEER HARGIS ENGINEERS, INC. 1201 3RD AVE, SUITE 600 SEATTLE, WA 98101 CONTACT: STEPHANIE ANDERSON PHONE: (206) 436-0458 PLUMBING & MECHANICAL ENGINEER HARGIS ENGINEERES, INC. 1201 3RD AVE, SUITE 600 SEATTLE, WA 98101 CONTACT: RAWLEY REESER PHONE: (206) 859-5385 ARCHITECT ARCADIS INC. 1420 5TH AVE, SUITE 2400 SEATTLE, WA 98101 CONTACT: STEPHANIE MEANS PHONE: (206) 661-1977 1. THE WORK DELINEATED IN THESE DRAWINGS AND DESCRIBED IN THE SPECIFICATION SHALL CONFORM TO ALL LOCAL CODES, STANDARDS, AND AUTHORITIES THAT HAVE JURISDICTION. CODES SHALL COMPLY WITH THE FOLLOWING: 2022 CALIFORNIA BUILDING CODE (CBC), 2021 INTERNATIONAL BUILDING CODE, ASCE/SEI 7-16, RMI/ANSI MH 16.1.2012. 2. THESE GENERAL NOTES SHALL APPLY TO ALL DRAWINGS AND GOVERN UNLESS OTHERWISE NOTED OR SPECIFIED. 3. VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS AT THE JOB SITE PRIOR TO THE START OF WORK. ANY DISCREPANCIES SHOULD BE REPORTED TO THE EOR IMMEDIATELY. 4. UNLESS OTHERWISE SHOWN OR NOTED, ALL TYPICAL DETAILS SHALL BE USED WHERE APPLICABLE. 5. ALL DETAILS SHALL BE CONSIDERED TYPICAL AT SIMILAR CONDITIONS. 6.CONSTRUCTION WORK WILL NOT BLOCK HALLWAYS OR MEANS OF EGRESS. 7.NO ON SITE WELDING REQUIRED. 8.A MINIMUM OF 18 INCHES IS PROVIDED BETWEEN THE TOP OF SHELVING MATERIAL TO THE LOWEST POINT OF SPRINKLER DEFLECTOR. 9.IF THE BUILDING INSPECTOR DETERMINES NON-COMPLIANCE WITH ANY ACCESSIBILITY PROVISIONS, HE/SHE SHALL REQUIRE COMPLETE, DETAILED PLANS CLEARLY SHOWING ALL EXISTING NON-COMPLYING CONDITIONS AND THE PROPOSED MODIFICATIONS TO MEET CURRENT ACCESSIBILITY PROVISIONS AFFECTED BY THE REMODEL (INCLUDING SITE PLAN, FLOOR PLAN, DETAILS, ETC.). THE PLANS MUST BE STAMPED BY THE FIELD INSPECTOR AND RESUBMITTED TO THE BUILDING DEVELOPMENT REVIEW DIVISION. 1.SUPPLY OF NEW STOCKROOM SHELVING, INCLUDING REGULAR PARTICLE BOARD SHELVES, FOOT PLATES, & CONCRETE ANCHORS IN AN EXISTING BUILDING. 2.SUPPLY OF SEISMIC CALCULATIONS, STAMPED AND SEALED DRAWINGS BY PROFESSIONAL STRUCTURAL ENGINEER FOR THE PURPOSE OF SHELVING PERMIT APPLICATION AT LOCAL JURISDICTION. 3.INSTALLATION OF THE NEW STOCKROOM SHELVING, BASED ON NON-UNION INSTALLER, WORKING ON MULTIPLE - PHASES OF INSTALLATION DURING NORMAL WORKING HOURS. 4.SHIPPING AND HANDLING BASED ON REGULAR FREIGHT TRUCK. 5.ALL HIGH SHELVING INSTALLED IS NOT TO INTRUDE ON THE SPRINKLER CLEARANCES. 6.REUSE EXISTING REMOVED SHELVING WHENEVER POSSIBLE. SCOPE OF WORK: 10. ALL SHELVING ANCHORS TO BE HILTI KWIK BOLT EXPANSION ANCHOR (ESR-4266). SPECIAL INSPECTION REQUIRED. 11. STORAGE STOCKING METHOD IS MANUAL. 12. BUILDING IS NOT ACCESSIBLE TO THE PUBLIC. 13. TYPE OF OCCUPANCY: GROUP M (MERCANTILE) 14. TYPE OF CONSTRUCTION: I-B 15. COMMODITY CLASSIFICATION: IV (BACK OF HOUSE STORAGE AREA) 16. USABLE STORAGE HEIGHT FOR EACH STORAGE AREA (REFER TO SHEET D1) 17. TYPICAL (E) MAIN FLOOR SLAB = MIN. 4" THICK REINFORCED SLAB ON-GRADE w/F'c = 4000 PSI (100 PSF MAX ALLOWABLE LIVE LOAD CAPACITY) TYPICAL UPPER FLOOR SLAB = MIN. 3-4" THICK REINFORCED LT WT CONCRETE SLAB OVER METAL DECK w/F'c = 4000 PSI (75 PSF MAX ALLOWABLE LIVE LOAD CAPACITY) STATEMENT OF SPECIAL INSPECTION VERIFICATION AND INSPECTION PERIODIC INSPECTED BY CONFIRM ANCHOR TYPE X 3rd PARTY CONFIRM CONCRETE COMPRESSIVE STRENGTH CONFIRM CONCRETE THICKNESS HOLE DIAMETER CLEAN OUT OF HOLE MINIMUM ANCHOR SPACING MINIMUM EDGE DISTANCE MINIMUM EMBEDMENT TIGHTENING TORQUE X X X X X X X X INSPECTOR INSPECTOR INSPECTOR INSPECTOR INSPECTOR INSPECTOR ICC-ES ESR-4266 HILTI KB TZ2, 3/8" DIA SECTION 4.4, 7.0 MINIMUM 4000 PSI 4" MINIMUM 3/8" DIA x 2-3/4" LONG PER SECTION 4.4, 7.0, FIGURE 2, TABLE 1 BULB/BLOW OUT - PER SECTION 4.3, 4.4 3.5" - PER SECTION 4.4, TABLE 3 6" - PER SECTION 4.4, TABLE 3 2.5" - PER SECTION 4.4, TABLE 1, 3 30 FT/LBS - PER SECTION 4.3, 4.4, TABLE 1 SHELVING COMPONENTS & WALL ATTACHMENT DETAILSD2 FOOT PLATE & FLOOR ANCHORING DETAILSD3 END FRAME & BAY ELEVATION DETAILS L0 SHEET GE N E R A L I N F O R M A T I O N RE V I S I O N S THE DESIGNS, CONCEPTS, AND FEATURES DEPICTED OR DESCRIBED HEREIN ARE THE EXCLUSIVE PROPERTY OF E-Z-RECT MANUFACTURING LTD. OR ITS REPRESENTATIVES AND ARE SUBMITTED IN CONFIDENCE. PERMISSION TO USE OR PRODUCE IN ANY WAY THIS PROPRIETARY INFORMATION IS EXPRESSLY WITHHELD. 2005. NORDSTROM 400 S. BALDWIN AVE, SUITE 200 SANTA ANITA SCALE:1 VICINITY MAP NTS SCALE:2 SITE MAP NTS PROJECT SITE NORDSTROM DA T E : BY : FI L E N A M E : SC A L E : AS N O T E D GL / d t E- Z - R E C T M A N U F A C T U R I N G L T D . 94 R I V E R S I D E D R I V E , N O R T H V A N C O U V E R , B C , V 7 H 2 M 6 PH O N E : ( 6 0 4 ) - 9 2 9 - 5 4 6 1 F A X : ( 6 0 4 ) - 9 2 9 - 5 1 8 4 ARCADIA, CA 91007 41 3 7 - L - 0 0 0 - 0 0 MA R 0 7 / 2 4 NO R D S T R O M AR C A D I A , C A 9 1 0 0 7 SA N T A A N I T A 40 0 S . B A L D W I N A V E , S U I T E 2 0 0 365 NE QUIMBY AVENUE BEND, OREGON 97701 ECLIPSE-ENGINEERING.COM (541) 389-9659 25 (FOIC) AFM 18 5 6 VEST 2104 T C2C4C4C4C4C4C4 C3 C4 C4 C4 C4 C4 C4 C4 C2 C2 3' MAGENTA DASHED LINES INDICATE CHICKEN WIRE BETWEEN BACK-TO-BACK UNITS, TYP. EXISTING SLICK RAILS, TYP. C4 C4 C4 C4 C4 C4 C3 C3 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 3'-41 2" C4 C4 C4 C4 C3 C3 C4 C4 3'-8 9 16" C4 C4 C4 C4 C4 C43'-8"3'-8"3'-8"3'-8"3'-8"3'-8"4'-11" 3'-3 1 16" C4 C4 C4 C4 A4 C4 C3 C4 C3 C4 C3 3'-8" 3'-5 9 16" C2C4 C4 C4 C4 C4 C4 C4 C4 3'-8" C4 C4 C4 C4 C4 C4 C4 C4 3'-8" C4 C4 C4 C3 A4 A4 A4 A4 A3 4'-4 9 16" WO R K B E N C H KIDS' SHOES STOCK 2106 A3.5 SPECIAL WELDED STM FOOT PLATE (SEE DETAIL 1 ON SHEET D3) DTM FOOT PLATE W/ SHIMS (SEE DETAIL 3 ON SHEET D3) STM FOOT PLATE W/ SHIMS (SEE DETAIL 2 ON SHEET D3) LEGEND L1.1 SHEET DA T E : BY : FI L E N A M E : SC A L E : FO O T P L A T E M A P RE V I S I O N S E- Z - R E C T M A N U F A C T U R I N G L T D . 94 R I V E R S I D E D R I V E , N O R T H V A N C O U V E R , B C , V 7 H 2 M 6 PH O N E : ( 6 0 4 ) - 9 2 9 - 5 4 6 1 F A X : ( 6 0 4 ) - 9 2 9 - 5 1 8 4 THE DESIGNS, CONCEPTS, AND FEATURES DEPICTED OR DESCRIBED HEREIN ARE THE EXCLUSIVE PROPERTY OF E-Z-RECT MANUFACTURING LTD. OR ITS REPRESENTATIVES AND ARE SUBMITTED IN CONFIDENCE. PERMISSION TO USE OR PRODUCE IN ANY WAY THIS PROPRIETARY INFORMATION IS EXPRESSLY WITHHELD. 2005. SCALE:1 SECOND FLOOR (STOCK 2106) FOOT PLATE MAP 3/32" = 1'-0" AS N O T E D GL / f m 41 3 7 - L - 0 0 1 - 0 1 MA R 2 0 / 2 4 NO R D S T R O M AR C A D I A , C A 9 1 0 0 7 SA N T A A N I T A 40 0 S . B A L D W I N A V E , S U I T E 2 0 0 SE C O N D F L O O R ( S T O C K 2 1 0 6 ) 365 NE QUIMBY AVENUE BEND, OREGON 97701 ECLIPSE-ENGINEERING.COM (541) 389-9659 25 TRAINING ROOM 216 PERSONNEL 217 CONF. 219 STOCK 212 FE FE RE-INSTALL ALL STYLMARK PARTITIONS, DOORS, MIRRORS, HARDWARE, CORNER GUARDS, AND FURNITURE UPON COMPLETION OF FINISH SCOPE 1 ACC STOCK 211 T T 233C WOMEN'S DR 232 FE STOCK 209 228A 209 WOMEN'S LOUNGE 206 207 FE-2 204 206 VESTIBULE 205 205 RELOCATE CASHWRAP FROM EXISTING t.b.d. DUMP 229 VEST 218 FEC 218 ENCORE 525 SF SALES 2D02 C1 A-811 15' - 1 1/2" A-811 E3 TYP (FOIC) AFM 18 ELEV. NO. 2 EL02 ELEV. NO. 1 EL01 FIELD AREA RUG (FOIC) F 0791 LINGERIE 2525 SF SALES 2D01 JAN 203 203 FEC EQ EQ EQ FIELD AREA RUG (FOIC) F 0793 EQ 7' - 2"DN TO FIRST G11 A-807 TYP SIM A-807 J11 1' - 0" UP FROM FIRST7 ALIGN 7' - 9"10' - 10 1/2" KIDS' GIRLS KIDS' DESIGNER 2' - 3" KIDS' BOYS 575 SF SALES 2D23 FIELD AREA RUG (FOIC) F 0789 STOCK 2108 12' - 5" 350 SF SALES 2D22 RELOCATE CASHWRAP FROM EXISTING KIDS'WEAR 1100 SF SALES 2D21 EQ EQ FIELD AREA RUG (FOIC) F 0788 FIELD AREA RUG (FOIC) F 0789 YA (FOIC) AFM 18 C1 A-811 A-802 G7 TYP AT 4 COLUMNS 4' - 6"RELOCATE CASHWRAP FROM EXISTING VIA C/INDIVIDUALIST VEST 2107 STAIR 2 2S2 DN 2107 KIDS' SHOES 675 SF SALES 2D18 18 (FOIC) AFM 18 KIDS' DR 2102 WOMEN'S DR 2101 DISPLAY 297 5 4 OS 3 2 1 ACC DISPLAY 293 3 2 1 OS FE DELIVERY STAGE 283 FREIGHT ELEV. NO. 1 CART. RM. 282 CO2-10 GENERATOR RM 277 ELEC. ROOM 278 FE-2 6 7 8 7 ACC 9 6 10 5 298 STOCK 298 STORAGE 294 MALL ENTRY 296 VEST 2104 C1 A-811 FEC 54 PROTH 6 7 8 ACC RELOCATE CASHWRAP FROM EXISTING KIDS' SHOES 3' - 9" 18' - 2"EQ EQ EQ EQ FIELD AREA RUG (FOIC) F 1002 C1 A-811 2102 1 2 3 4 FEC2101 SIM A-807 J11 SIM 292 289 FE LOUNGE AREA 292A STOCK 289 WOMEN'S DR 292 MANAGER 218 JAN 279 IDF CLOSET #1 284 1' - 6"FIELD AREA RUG (FOIC) F 0789 9' - 0" FE 7 STAIR 1 2S1 6 UP DN BABY APPAREL/GEAR 1475 SF SALES 2D17 FIELD AREARUG (FOIC) F 0789 18 2' - 10" (FOIC) AFM FIELD AREARUG (FOIC) F 0788 (FOIC) AFM 18 ACTIVE AND SWIM 2700 SF SALES 2D14 288 VEST 288 4 284 9 5 8 PURPLE "K" MANAGER 218 MANAGER 218 FIELD AREA RUG (FOIC) F 0797 TBD 6050 SF SALES 2D13 (FOIC) AFM FIELD AREA RUG (FOIC) F 0797 18 C1 A-811 G5 A-811 FEC 287 STOCK 287 3 286 1 ACC 2 3275 SF SALES 2D16 9' - 0" CAFE 271 KITCHEN 276 FIELD AREA RUG (FOIC) F 0789 A-807 J11 TYP AT COLUMNS AT ESCALATOR ALIGN 9' - 0" 1' - 6"FIELD AREA RUG (FOIC) F 0788 FIELD AREA RUG (FOIC) F 1002 18 6' - 0" 19' - 0"TBD (DEMIN) 1400 SF SALES 2D12 14' - 8" FEC (FOIC) AFM RELOCATE CASHWRAP FROM EXISTING COLLECTORS EQ EQ EQ EQ ALIGN ALIGN EQ FIELD AREA RUG (FOIC) F 0797 EQ 11' - 0"EQ FIELD AREA RUG (FOIC) F 1002 EQ ALIGN ALIGN EQ EQ 13' - 1"SPACE 475 SF SALES 2D08 A-807 J11 G11 SIM A-807 TYP FIELD AREA RUG (FOIC) F 0791 5' - 2" POV/PETITES 2650 SF SALES 2D03 1' - 4" ALIGN 18 (FOIC) AFM RELOCATE CASHWRAP FROM EXISTING BP/SAVVY 16 DRESSES 1350 SF SALES 2D06 EQ FIELD AREA RUG (FOIC) F 0772 2' - 6" FIELD AREA RUG (FOIC) F 0773 FIELD AREA RUG (FOIC) F 0773 SECURITY 268 FE EQ 9' - 10"EQ EQ EQ EQ (FOIC) AFM RELOCATE CASHWRAP FROM EXISTING VIA C/INDIVIDUALIST 6' - 0" 6' - 8 1/2"FIELD AREA RUG (FOIC) F 0773 FIELD AREA RUG (FOIC) F 0793 1' - 8" 4' - 9" FIELD AREA RUG (FOIC) F 0772 9' - 0" VIA C/INDY 2475 SF SALES 2D07 FIELD AREA RUG (FOIC) F 0773 5' - 6 1/2"14' - 3" 7' - 7" 262D COLLECTORS 4400 SF SALES 2D09 (FOIC) AFM 4 T.V. SECURITY 264 SECURITY 266 STORAGE 267 5' - 6" E 37 262E - 3 FIELD AREA RUG (FOIC) F 0772 229 7 232 6 5 4 OS 233A C1 A-811 1 233D WOMEN'S DR 233 233B 233E FE234 1075 SF SALES 2D04 1 ACC 242A 243A 247 C1 A-811 5' - 6" EQ EQ BURBERRY 600 SF SALES 2D11 1 DRESSING ROOM FINISHES PER DETAIL E7 A-811 262A 263 WOMEN'S DR 262 262B 262C 2 ACC 6' - 6" 251A MAIL MESSAGE 214 STOCK 234 2 HALLWAY 228 3 2 ASSISTANT 222 MANAGER 218 STORE MANAGER 221 C.R. 223 STORAGE 226 MANAGER 218 GIFT WRAP 227 -37 - VEST 236 2 RE-INSTALL HALL MIRROR, HARDWARE, CORNER GUARDS, AND FURNITURE UPON COMPLETION OF FINISH SCOPE 3 4 ACC FE 228B -37 ORDER PICK-UP - 242C 3 242B 242D 243B FE STOCK 248 243D 243C 1 ACC 1 251B 252 STOCK 252 FE 253 VEST 254 254 E 37 - 258 CORRIDOR 258 STOCK 244 FE STOCK 253 3 4' - 11"4' - 1" FE 239 2 STOCK 247 2 PACKAGE SECURITY 257 FE STOCK 239 5 6 BOILER ROOM 256 4 7 CO2-5 ACC 8 ACC MANAGER 218 3 W O M E N ' S D R 2 8 6 T T T T T EL E V . M A C H I N E R O O M 20 4 WO M E N ' S T O I L E T 20 7 SO U T H E N T R Y 20 1 2' - 1 0 " EL E V A T O R L O B B Y 20 2 7' - 5 1 / 2 " 1' - 1 1 " 7' - 3 " 4' - 0 " 6' - 4 " LP I N T E R N A L 21 5 12 ' - 0 " 3' - 0 " 7' - 3 " 3' - 0 " EQ EQ 7' - 3 " 4' - 0 " 1' - 7 1 / 2 " 8" 4' - 0 " EQ 6' - 5 " 3' - 0 " EQ 1' - 0 1 / 2 " 7' - 8 " 2' - 5 " 9' - 0 " 3' - 8 " AL I G N 4' - 0 " 4' - 0 " 7' - 9 " 6' - 1 1 1 / 2 " 5' - 9 " 11 ' - 3 1 / 2 " AL I G N 9' - 3 " 4' - 3 " G1 1 A- 8 0 7 AL I G N 8' - 5 " 9' - 2 " 6' - 6 " 4' - 0 " 1' - 0 " WO M E N ' S D R 24 2 WO M E N ' S D R 24 3 1' - 9 " EQ EQ 4' - 0 " 6' - 0 " 6' - 0 " 7' - 6 1 / 2 " EQ EQ AL I G N WO M E N ' S D R 25 1 6' - 1 0 " 4' - 0 " 6" 4' - 0 " 4' - 1 0 " EQ EQ 1' - 0 " NO R T H E N T R Y 26 9 EL E C . C L O S E T 26 3 EM P L O Y E E L O C K E R S 26 1 EM P L O Y E E D R 25 9 T C2C4C4C4C4C4C4 C3 C4 C4 C4 C4 C4 C4 C4 C2 C2 3' TTTTTTTTTTTT T T T T MAGENTA DASHED LINES INDICATECHICKEN WIRE BETWEENBACK-TO-BACK UNITS, TYP. WALL TIE, TYP. EXISTING SLICK RAILS, TYP. C4 C4 C4 C4 C4 C4 C3 C3 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 3'-412" C4 C4 C4 C4 C3 C3 C4 C4 3'-8916" C4 C4 C4 C4 C4 C43'-8"3'-8"3'-8"3'-8"3'-8"3'-8"4'-11" 3'-3116" T C4 C4 C4 TTT C4 A4 T T C4 C3 C4 C3 C4 C3 3'-8" 3'-5916" C2C4 C4 C4 C4 C4 C4 C4 C4 3'-8" C4 C4 C4 C4 C4 C4 C4 C4 3'-8" T C4 C4 C4 TTT T C3 A4 T T A4 A4 TT A4 T T A3.5 TT A3 TT 4'-4916" WO R K B E N C H KIDS' SHOES STOCK 2106 L1 SHEET DA T E : BY : FI L E N A M E : SC A L E : SH E L V I N G L A Y O U T RE V I S I O N S E- Z - R E C T M A N U F A C T U R I N G L T D . 94 R I V E R S I D E D R I V E , N O R T H V A N C O U V E R , B C , V 7 H 2 M 6 PH O N E : ( 6 0 4 ) - 9 2 9 - 5 4 6 1 F A X : ( 6 0 4 ) - 9 2 9 - 5 1 8 4 THE DESIGNS, CONCEPTS, AND FEATURES DEPICTED OR DESCRIBED HEREIN ARE THE EXCLUSIVE PROPERTY OF E-Z-RECT MANUFACTURING LTD. OR ITS REPRESENTATIVES AND ARE SUBMITTED IN CONFIDENCE. PERMISSION TO USE OR PRODUCE IN ANY WAY THIS PROPRIETARY INFORMATION IS EXPRESSLY WITHHELD. 2005. SCALE:1 SECOND FLOOR (STOCK 2106) SHELVING LAYOUT 3/32" = 1'-0" AS N O T E D GL / d t 41 3 7 - L - 0 0 1 - 0 1 MA R 1 8 / 2 4 NO R D S T R O M AR C A D I A , C A 9 1 0 0 7 SA N T A A N I T A 40 0 S . B A L D W I N A V E , S U I T E 2 0 0 SE C O N D F L O O R ( S T O C K 2 1 0 6 ) 365 NE QUIMBY AVENUE BEND, OREGON 97701 ECLIPSE-ENGINEERING.COM (541) 389-9659 25 POST CONNECTOR TABS MUST BE LOCKED IN PLACE FOR SAFETY, TYP. TPC 96" 12" 1115 16", 1515 16" TPC 12" TPC 12" TPC TPC 24" TPC TPC 12" 12" USE THE THREE TOP SLOTS POST CONNECTOR SLOTS, TYP. 96" 12" 1115 16" 12" 12" 24" 12" 12" 1115 16" TPC TPC TPC TPC TPC TPC TPC 5" x 1/4" THICK HARDBOARD KICK PLATE PROVIDES FLUSH TOE SPACE CLOSURE AT END OF EACH ROW, TYP MAGENTA DASHED LINES INDICATE CHICKEN WIRE BETWEEN BACK TO BACK "C" UNITS,TYP. TFCV TFCV TFCV TFCV TBC TBC TWB 91 2" - 9 EMPTY SLOTS 123 4" - 12 EMPTY SLOTS 123 4" - 12 EMPTY SLOTS 123 4" - 12 EMPTY SLOTS 1213 16" - 12 EMPTY SLOTS 12 1 16" - 12 EMPTY SLOTS 1131 32" - 12 EMPTY SLOTS 11 2", TYP.211 2", 341 2", 421 8", 461 2" "A" & "C" UNITS BAY ELEVATION "A" & "C" UNITS END FRAME ELEVATION 96" 48" 36" SPECIAL STM FOOT PLATE W/ WELDED BASE PLATE C/W (2) ANCHORS, TYP. CONNECTOR LOCKING CLIP ON TOP TFCV & BOTTOM TWB CONNECTORS, TYP. TFCV TFCV TFCV TFCV TBC TBC TWB 123 4" - 12 EMPTY SLOTS 123 4" - 12 EMPTY SLOTS 123 4" - 12 EMPTY SLOTS 1213 16" - 12 EMPTY SLOTS 12 1 16" - 12 EMPTY SLOTS 1131 32" - 12 EMPTY SLOTS 211 2", 341 2", 461 2" BACK TO BACK "C" UNITS BAY ELEVATION 96" TFCV (BACK ONLY) SPECIAL DTM FOOT PLATE W/ WELDED BASE PLATE C/W (2) ANCHORS, TYP. RE V I S I O N S E- Z - R E C T M A N U F A C T U R I N G L T D . 94 R I V E R S I D E D R I V E , N O R T H V A N C O U V E R , B C , V 7 H 2 M 6 PH O N E : ( 6 0 4 ) - 9 2 9 - 5 4 6 1 F A X : ( 6 0 4 ) - 9 2 9 - 5 1 8 4 THE DESIGNS, CONCEPTS, AND FEATURES DEPICTED OR DESCRIBED HEREIN ARE THE EXCLUSIVE PROPERTY OF E-Z-RECT MANUFACTURING LTD. OR ITS REPRESENTATIVES AND ARE SUBMITTED IN CONFIDENCE. PERMISSION TO USE OR PRODUCE IN ANY WAY THIS PROPRIETARY INFORMATION IS EXPRESSLY WITHHELD. 2005.D1 SHEET EN D F R A M E & B A Y E L E V A T I O N D E T A I L S SCALE:1 (STOCK 2106) END FRAME AND BAY ELEVATION DETAILS 7/8" = 1'-0" DA T E : BY : FI L E N A M E : SC A L E : AS N O T E D GL / d t NOTES: 1.TRIM-LINE STEEL SHELVING FRAMEWORK C/W PARTICLE BOARD SHELVES, TYP. 2.ALL WOOD SHELVES ARE NON-FIRE RETARDANT PARTICLE BOARD (PB) 3.THE MAXIMUM LOAD PER SHELF = 30 LBS PER 11" DEEP UNIT, TYP. 4.THE MAXIMUM LOAD PER SHELF = 40 LBS PER 15" DEEP UNIT, TYP. 5.REFER TO SHEETS L1.1 & D3 FOR FOOT PLATE & ANCHORING DETAILS. 41 3 7 - D - 0 0 1 - 0 0 MA R 1 8 / 2 4 NO R D S T R O M AR C A D I A , C A 9 1 0 0 7 SA N T A A N I T A 40 0 S . B A L D W I N A V E , S U I T E 2 0 0 365 NE QUIMBY AVENUE BEND, OREGON 97701 ECLIPSE-ENGINEERING.COM (541) 389-9659 25 2" VARIES Ø 5 16" x 21 2" LONG GRADE 5 BOLT C/W NYLON LOCK NUT TYP. 36" 14 GA. VARIES 23 4" 1" TYP. 1 2" 1 2" 5 16" I.D. x 7 8" O.D. WASHER 18" FROM TOP OF POST SECURE POST TO 1" x 3" WOOD STRIP WITH #10 x 21 2" ROUND HEAD ROBERTSON WOOD SCREW TRIM-LINE POST 1" x 3" PRIMED WOOD STRIP ATTACH 1" x 3" WOOD STRIP INTO WALL STUD EVERY 16" WITH #10 x 21 2" ROUND HEAD ROBERTSON WOOD SCREW THROUGH DRY WALL VARIES 1" TYP. 2 7 16" 13 GA. 48" 1" TYP. 2 7 16" VARIES 13 GA.13 16" 11 8" 1" VARIES 13 GA. 11 2" 19 32" RE V I S I O N S E- Z - R E C T M A N U F A C T U R I N G L T D . 94 R I V E R S I D E D R I V E , N O R T H V A N C O U V E R , B C , V 7 H 2 M 6 PH O N E : ( 6 0 4 ) - 9 2 9 - 5 4 6 1 F A X : ( 6 0 4 ) - 9 2 9 - 5 1 8 4 D2 SHEET WA L L A T T A C H M E N T D E T A I L FR A M E C O N N E C T O R D E T A I L S BO L T O N F O O T P L A T E D E T A I L PO S T C O N N E C T O R D E T A I L BA C K T O B A C K B O L T I N G D E T A I L SCALE:1 TRIM-LINE TPC POST CONNECTOR 6" = 1'-0" DA T E : BY : FI L E N A M E : SC A L E : AS N O T E D THE DESIGNS, CONCEPTS, AND FEATURES DEPICTED OR DESCRIBED HEREIN ARE THE EXCLUSIVE PROPERTY OF E-Z-RECT MANUFACTURING LTD. OR ITS REPRESENTATIVES AND ARE SUBMITTED IN CONFIDENCE. PERMISSION TO USE OR PRODUCE IN ANY WAY THIS PROPRIETARY INFORMATION IS EXPRESSLY WITHHELD. 2005. SCALE:2 TRIM-LINE TWB FRAME CONNECTOR 6" = 1'-0" SCALE:3 TRIM-LINE TBC FRAME CONNECTOR 6" = 1'-0" SCALE:6 WALL ATTACHMENT DETAIL 6" = 1'-0"SCALE:4 TRIM-LINE TFCV FRAME CONNECTOR 6" = 1'-0" GL / d t SCALE:5 BACK TO BACK BOLTING DETAIL 6" = 1'-0" 41 3 7 - D - 0 0 2 - 0 0 MA R 0 7 / 2 4 NO R D S T R O M AR C A D I A , C A 9 1 0 0 7 SA N T A A N I T A 40 0 S . B A L D W I N A V E , S U I T E 2 0 0 365 NE QUIMBY AVENUE BEND, OREGON 97701 ECLIPSE-ENGINEERING.COM (541) 389-9659 25 4" 31 2" x 21 2" x 3" x 11 GA. FOOT PLATE CONCRETE FLOOR 14 GA. TRIM-LINE POST 13 16"11 2" Ø5 16" x 11 2" LONG GRADE 5 BOLT C/W NYLON LOCK NUT 3" EMB. Ø3 8" x 33 4" HILTI KWIK BOLT TZ KB2 CONCRETE WEDGE ANCHOR AS PER ESR-4266 W/ MIN. 3" EMB., TYP.2" 5" 4" 3" 4 PLCS.12"14" 3" 1 8 ORIENTATION OF FOOT PLATE TO PREVENT "TRIP HAZARD" 4" 31 2" x 21 2" x 3" x 11 GA. FOOT PLATE CONCRETE FLOOR 14 GA. TRIM-LINE POST 13 16"11 2" Ø 5 16" x 11 2" LONG GRADE 5 BOLT C/W NYLON LOCK NUT 3" EMB. Ø3 8" x 33 4" HILTI KWIK BOLT TZ KB2 CONCRETE WEDGE ANCHOR AS PER ESR-4266 W/ MIN. 3" EMB., TYP.2" 2" ORIENTATION OF FOOT PLATE TO PREVENT "TRIP HAZARD" 11 2" Ø 5 16" x 21 2" LONG GRADE 5 BOLT C/W NYLON LOCK NUT TWO 14 GA. TRIM-LINE POSTS 13 16"13 16" 31 2" x 31 2" x 3" x 11 GA. FOOT PLATE 3" Ø3 8" x 33 4" HILTI KWIK BOLT TZ KB2 CONCRETE WEDGE ANCHOR AS PER ESR-4266 W/ MIN. 3" EMB., TYP. 4" CONCRETE FLOOR 3" 1 4 ORIENTATION OF FOOT PLATE TO PREVENT "TRIP HAZARD" 3" EMB. (2) STM SHIMS, TYP. 5" x 4" x 5 16" STEEL FOOT PLATE AISLE SIDE AISLE SIDE AISLE SIDE CONCRETE FLOOR CONCRETE FLOOR CONCRETE FLOOR (2) 31 2" x 31 2" x 3" x 11 GA. SHIMS (2) 31 2" x 21 2" x 3" x 11 GA. SHIMS RE V I S I O N S E- Z - R E C T M A N U F A C T U R I N G L T D . 94 R I V E R S I D E D R I V E , N O R T H V A N C O U V E R , B C , V 7 H 2 M 6 PH O N E : ( 6 0 4 ) - 9 2 9 - 5 4 6 1 F A X : ( 6 0 4 ) - 9 2 9 - 5 1 8 4 D3 SHEET DT M B O L T - O N F O O T P L A T E A N C H O R I N G D E T A I L SP E C I A L W E L D E D B O L T - O N S T M F O O T P L A T E A N C H O R I N G D E T A I L ST M B O L T - O N F O O T P L A T E A N C H O R I N G D E T A I L DA T E : BY : FI L E N A M E : SC A L E : AS N O T E D SCALE:1 SPECIAL WELDED BOLT-ON STM FOOT PLATE W/ (2) ANCHORS DETAIL 6" = 1'-0" GL / f m 41 3 7 - D - 0 0 2 - 0 0 MA R 0 7 / 2 4 NO R D S T R O M AR C A D I A , C A 9 1 0 0 7 SA N T A A N I T A 40 0 S . B A L D W I N A V E , S U I T E 2 0 0 THE DESIGNS, CONCEPTS, AND FEATURES DEPICTED OR DESCRIBED HEREIN ARE THE EXCLUSIVE PROPERTY OF E-Z-RECT MANUFACTURING LTD. OR ITS REPRESENTATIVES AND ARE SUBMITTED IN CONFIDENCE. PERMISSION TO USE OR PRODUCE IN ANY WAY THIS PROPRIETARY INFORMATION IS EXPRESSLY WITHHELD. 2005. SCALE:2 STM FOOT PLATE C/W (2) SHIMS & (1) ANCHOR DETAIL 6" = 1'-0"SCALE:3 DTM FOOT PLATE C/W (2) SHIMS & (1) ANCHOR DETAIL 6" = 1'-0" 365 NE QUIMBY AVENUE BEND, OREGON 97701 ECLIPSE-ENGINEERING.COM (541) 389-9659 25 STRUCTURAL CALCULATIONS Steel Storage Shelving By E-Z-Rect Manufacturing, LTD Nordstrom Santa Anita 400 South Baldwin Avenue - Suite #200 Arcadia, California 91007 Prepared For: E-Z-Rect Manufacturing, LTD 94 Riverside Drive North Vancouver, BC V7H 2M6, Canada Please note: the calculations contained within justify the seismic resistance of the shelving systems for both vertical and lateral forces as required by the 2022 CBC, 2021 IBC, ASCE 7-16, and ANSI/RMI- MH16.1 (2012). These storage shelves are not accessible to the general public. 25 Nordstrom Arcadia, California 91007 3/19/2024 RVC E-Z-RECT MANUFACTURING STEEL STORAGE SHELVING - LIGHT RETAIL CODES:Current Editions of the: IBC & CBC & ASCE 7 & RMI Design Inputs:Steel Storage Shelving: "A" Units (Second Floor) Shelving Geometry - Height of Shelving Unit = 8.0 ft Steel Yield Stress =33 ksi Width of Shelving Unit = 4.0 ft Modulus of Elast. =29000 ksi Depth of Shelving Unit = 1.3 ft Number of Shelves/Unit = 7 Eff. Length Factor =1.7 Vertical Shelf Spacing = 14.8 in Unbraced Length X =14.8 in Back to Back Units?NO Unbraced Length Y =12.0 in Are There Mobile Units?NO Type of Post?14ga Trimline Post Units per Anti-Tip Track = N/A Type of Beam?Trimline_TFCV Trimline_TBC Shelving Loading - Trimline_TWB Live Load per Shelf = 8.0 psf Display On Plaque Near Shelving Units Dead Load per Shelf = 3.5 psf Maximum Weight Per Shelf = 40 lbs Weight of Each Post = 8.0 lbs Weight of Mobile Carriage = N/A lbs Floor Load Calculations: Total Load on Each Post = 209 lbs Total Load On Each Unit = 418 lbs Floor Area Load = 7.7 ft2 Allowable Floor Loading = 75 psf For Upper Floor Slab Over Metal Decking Floor Load Under Shelf = 54 psf OK FOR 75psf RETAIL FLOOR LOADING Seismic Information - Importance Factor - 1.0 Not Open to the Public SDC:D - Sds Site Class - D - Default D - Sd1 Mapped Accel. Parameters: Ss = 2.018 Fa = 1.200 Sms = 2.422 Sds = 1.614 S1 = 0.721 Fv = 1.700 Sm1 = 1.226 Sd1 = 0.817 Structural System - ASCE 7 Section 15.5.3 Steel Storage Shelving:R = 4 ap = 2.5 Ip = 1.0 Average Roof Height = 45 ft 0'-0" For Ground Floor Location Height of Base Attachment = 18.25 ft Second Floor Shear Coeff Boundaries = Vmin = 0.484 Vmax = 2.583 Design Base Shear Coeff = Vt = 0.512 Adjusted For ASD 1/15 Nordstrom Arcadia, California 91007 3/19/2024 RVC Lateral Force Distribution: per ASCE 7 Section 15.5.3.3 Total Dead Load per Shelf = 19.8 lbs Total Live Load per Shelf = 40.0 lbs Lateral DL Force per Shelf = 10.1 lbs Lateral LL Force per Shelf = 20.5 lbs 67% of LL Force per Shelf = 13.7 lbs Total DL Base Shear = 70.9 lbs Total LL Base Shear = 143.3 lbs LC1: Each Shelf is Loaded to 67% of its Live Weight Cumulative Moment:15408 in-lbs Total Base Shear = 166.9 lbs Controlling Load Case By Inspection Height:Load:% Per Level:Lateral Force/Level: Base = 0 in 0 lbs 0.0%F0 = 0 lbs h1 = 3 in 40 lbs 0.9%F1 = 1.5 lbs h2 = 18 in 40 lbs 5.4%F2 = 9.0 lbs h3 = 33 in 40 lbs 9.8%F3 = 16.4 lbs h4 = 47 in 40 lbs 14.3%F4 = 23.8 lbs h5 = 62 in 40 lbs 18.7%F5 = 31.3 lbs h6 = 77 in 40 lbs 23.2%F6 = 38.7 lbs h7 = 92 in 40 lbs 27.7%F7 = 46.2 lbs h8 = 0 in 0 lbs 0.0%F8 = 0.0 lbs h9 = 0 in 0 lbs 0.0%F9 = 0.0 lbs h10 = 0 in 0 lbs 0.0%F10 = 0.0 lbs h11 = 0 in 0 lbs 0.0%F11 = 0.0 lbs h12 = 0 in 0 lbs 0.0%F12 = 0.0 lbs h13 = 0 in 0 lbs 0.0%F13 = 0.0 lbs h14 = 0 in 0 lbs 0.0%F14 = 0.0 lbs h15 = 0 in 0 lbs 0.0%F15 = 0.0 lbs h16 = 0 in 0 lbs 0.0%F15 = 0.0 lbs h17 = 0 in 0 lbs 0.0%F15 = 0.0 lbs h18 = 0 in 0 lbs 0.0%F15 = 0.0 lbs h19 = 0 in 0 lbs 0.0%F15 = 0.0 lbs h20 = 0 in 0 lbs 0.0%F15 = 0.0 lbs Sum = 100%Total = 166.9 lbs LC 2: Top Shelf Only is Loaded to 100% of its Live Weight Total Base Shear = 91.3 lbs Does Not Control By inspection, the seismic distribution for intermediate shelves without live load (case 2) is negligible. Calculate the moment for each column based on the total seismic base shear for each shelf being loaded to 67% of it's allowable live weight. 2/15 Nordstrom Arcadia, California 91007 3/19/2024 RVC Column Calculations - Combined Bending and Axial Post Type: 14ga Trimline Post x - Down y - Cross Width = 0.81 in r = 0.516 0.317 in Depth = 1.56 in S = 0.104 0.073 in3 Thickness = 0.07 in I = 0.078 0.030 in4 Fy =33 ksi Ap = 0.294 in2 E = 29000 ksi Ae = 0.275 in2 K = 1.7 Column Bending Calculations - Max Column Moment = 39.6 ft-lbs (down)43.8 ft-lbs (cross) Allowable Bending Stress = 19.8 ksi 19.8 ksi Bending Stress on Column = 4.6 ksi 7.2 ksi Bending Stress OK Bending Stress OK Shelf Tab Connection - Moment From Post = 72.0 ft-lbs Short Direction Moment From Post = 22.5 ft-lbs Long Direction *MAX FOR TFCV BEAMS Shear on Tab = 296.9 lbs Short Direction Thickness of Tab = 0.075 in Shear on Tab = 214.6 lbs Long Direction Thickness of Tab = 0.090 in Depth of Tab = 0.375 in For Shear Allowable Shear Stress = 13.2 ksi Shear Stress on Tab = 10.6 ksi Shear Stress OK Worst Case Column Axial Calculations - Allowable Buckling Stress = 69.2 ksi Ω = 1.8 Elastic Flexural Buckling = 46.3 ksi Allowable Comp. Stress = 24.5 ksi Nominal Column Capacity = 6734 lbs Allowable Column Capacity = 3741 lbs Axial RMI LC #2 = 209 lbs Axial Load OK RMI LC #5 = N/A RMI LC #6 = 375 lbs - Down Aisle 782 lbs - Cross Aisle Critical Buckling Load = 20289 lbs Cm = 0.85 αx = 0.967 αy = 0.931 Combined Bending And Axial Forces - Axial Stress Unity = 0.100 Down 0.209 Cross Bending Stress Unity = 0.202 Down 0.331 Cross Combined Stress Unity = 0.540 Column is Adequate 3/15 Nordstrom Arcadia, California 91007 3/19/2024 RVC Overturning and Anti-Tip Calculations Overturning Forces - Total Weight = 326 lbs Load Case 1: Dead Load + 67% Live Load Total Lateral Force = 167 lbs Overturning Force = 740 ft*lbs Controlling Overturning Force Total Weight = 178 lbs Load Case 2: Dead Load + 100% Top Shelf Total Lateral Force = 91 lbs Overturning Force = 534 ft*lbs Does Not Control Tension Force per Anchor = 531 lbs Shear Force per Anchor = 83 lbs Vertical Seismic Force = 36.9 lbs USE: Hilti Kwik Bolt TZ2 ANCHOR BOLTS Allowable Tension Force = 1154 lbs For 4000 Concrete Allowable Shear Force = 1657 lbs (2) 0.375in Diameter x 2.5in Embedment Overstrength Factor = 2.0 Combined Loading = 0.920 Floor Anchors are Adequate Steel Base Plate Design - 11ga Angle Clips Bolted to Post w/ 5/16" Bolt Tension Per Angle Clip = 531 lbs Thickness of Angle = 0.12 in Fy = 36 ksi Width of Angle = 1.5 in Fu = 65 ksi Moment Arm to Bolt = 1.375 in Gross Area of Clip = 0.176 in2 Ω, Yielding = 1.67 Net Area of Clip = 0.132 in2 Ω, Ultimate = 2 Allowable Tensile Strength = 3803 lbs Minimum of yielding in gross or fracture in the net section Bolt Connection Bearing Area = 0.023 in2 5/16" Bolt on Post Gauge Allowable Bearing Strength = 693 lbs Controlling Tensile Capacity = 693 lbs Base Plate Stress Unity = 0.77 Bending Stress OK 4/15 Nordstrom Arcadia, California 91007 3/19/2024 RVC Shelf Beam Calculations Type of Shelf Beam:Trimline_TFCV Steel Yield Stress = 33 ksi Shelf DL = 3.5 psf Modulus of Elast. = 29000 ksi Shelf LL = 8.0 psf Area of Beam = 0.170 in2 Beam Length = 4.0 ft Section Modulus of Beam = 0.024 in3 Beam Tributary = 0.6 ft Moment of Inertia of Beam = 0.017 in4 Allowable Load per Shelf = 40 lbs Shelf Distributed Load = 7.2 plf Distributed Load Allowable Bending Stress = 16.4 ksi (reduced for LTB) Allowable Shear Stress = 13.2 ksi Maximum Beam Moment = 14.4 ft-lbs Simple Span Maximum Design Shear = 14.4 lbs Beam Bending Stress = 7.10 ksi Beam Shear Stress = 0.08 ksi Bending Stress Unity = 0.434 Bending Stress OK Shear Stress Unity = 0.006 Shear Stress OK Max Allowable Deflection = 0.267 in L/180 Maximum Beam Deflection = 0.085 in Deflection OK 5/15 Nordstrom Arcadia, California 91007 3/19/2024 RVC E-Z-RECT MANUFACTURING STEEL STORAGE SHELVING - LIGHT RETAIL CODES:Current Editions of the: IBC & CBC & ASCE 7 & RMI Design Inputs:Steel Storage Shelving: "C" Units (Second Floor) Shelving Geometry - Height of Shelving Unit = 8.0 ft Steel Yield Stress =33 ksi Width of Shelving Unit = 4.0 ft Modulus of Elast. =29000 ksi Depth of Shelving Unit = 2.0 ft Number of Shelves/Unit = 7 Eff. Length Factor =1.7 Vertical Shelf Spacing = 14.8 in Unbraced Length X =14.8 in Back to Back Units?YES Unbraced Length Y =12.0 in Are There Mobile Units?NO Type of Post?14ga Trimline Post Units per Anti-Tip Track = N/A Type of Beam?Trimline_TFCV Trimline_TBC Shelving Loading - Trimline_TWB Live Load per Shelf = 7.5 psf Display On Plaque Near Shelving Units Dead Load per Shelf = 3.5 psf Maximum Weight Per Shelf = 30 lbs Per Back to Back Shelf Weight of Each Post = 8.0 lbs Weight of Mobile Carriage = N/A lbs Floor Load Calculations: Total Load on Each Post = 162 lbs Total Load On Each Unit = 648 lbs Floor Area Load = 10.7 ft2 Allowable Floor Loading = 75 psf For Upper Floor Slab Over Metal Decking Floor Load Under Shelf = 60 psf OK FOR 75psf RETAIL FLOOR LOADING Seismic Information - Importance Factor - 1.0 Not Open to the Public SDC:D - Sds Site Class - D - Default D - Sd1 Mapped Accel. Parameters: Ss = 2.018 Fa = 1.200 Sms = 2.422 Sds = 1.614 S1 = 0.721 Fv = 1.700 Sm1 = 1.226 Sd1 = 0.817 Structural System - ASCE 7 Section 15.5.3 Steel Storage Shelving:R = 4 ap = 2.5 Ip = 1.0 Average Roof Height = 45 ft 0'-0" For Ground Floor Location Height of Base Attachment = 18.25 ft Second Floor Shear Coeff Boundaries = Vmin = 0.484 Vmax = 2.583 Design Base Shear Coeff = Vt = 0.512 Adjusted For ASD 6/15 Nordstrom Arcadia, California 91007 3/19/2024 RVC Lateral Force Distribution: per ASCE 7 Section 15.5.3.3 Total Dead Load per Shelf = 32.6 lbs Total Live Load per Shelf = 60.0 lbs Lateral DL Force per Shelf = 16.7 lbs Lateral LL Force per Shelf = 30.7 lbs 67% of LL Force per Shelf = 20.6 lbs Total DL Base Shear = 116.7 lbs Total LL Base Shear = 214.9 lbs LC1: Each Shelf is Loaded to 67% of its Live Weight Cumulative Moment:24068 in-lbs Total Base Shear = 260.6 lbs Controlling Load Case By Inspection Height:Load:% Per Level:Lateral Force/Level: Base = 0 in 0 lbs 0.0%F0 = 0 lbs h1 = 3 in 30 lbs 0.9%F1 = 2.4 lbs h2 = 18 in 30 lbs 5.4%F2 = 14.0 lbs h3 = 33 in 30 lbs 9.8%F3 = 25.6 lbs h4 = 47 in 30 lbs 14.3%F4 = 37.2 lbs h5 = 62 in 30 lbs 18.7%F5 = 48.9 lbs h6 = 77 in 30 lbs 23.2%F6 = 60.5 lbs h7 = 92 in 30 lbs 27.7%F7 = 72.1 lbs h8 = 0 in 0 lbs 0.0%F8 = 0.0 lbs h9 = 0 in 0 lbs 0.0%F9 = 0.0 lbs h10 = 0 in 0 lbs 0.0%F10 = 0.0 lbs h11 = 0 in 0 lbs 0.0%F11 = 0.0 lbs h12 = 0 in 0 lbs 0.0%F12 = 0.0 lbs h13 = 0 in 0 lbs 0.0%F13 = 0.0 lbs h14 = 0 in 0 lbs 0.0%F14 = 0.0 lbs h15 = 0 in 0 lbs 0.0%F15 = 0.0 lbs h16 = 0 in 0 lbs 0.0%F15 = 0.0 lbs h17 = 0 in 0 lbs 0.0%F15 = 0.0 lbs h18 = 0 in 0 lbs 0.0%F15 = 0.0 lbs h19 = 0 in 0 lbs 0.0%F15 = 0.0 lbs h20 = 0 in 0 lbs 0.0%F15 = 0.0 lbs Sum = 100%Total = 260.6 lbs LC 2: Top Shelf Only is Loaded to 100% of its Live Weight Total Base Shear = 147.4 lbs Does Not Control By inspection, the seismic distribution for intermediate shelves without live load (case 2) is negligible. Calculate the moment for each column based on the total seismic base shear for each shelf being loaded to 67% of it's allowable live weight. 7/15 Nordstrom Arcadia, California 91007 3/19/2024 RVC Column Calculations - Combined Bending and Axial Post Type: 14ga Trimline Post x - Down y - Cross Width = 0.81 in r = 0.516 0.317 in Depth = 1.56 in S = 0.104 0.073 in3 Thickness = 0.07 in I = 0.078 0.030 in4 Fy =33 ksi Ap = 0.294 in2 E = 29000 ksi Ae = 0.275 in2 K = 1.7 Column Bending Calculations - Max Column Moment = 65.8 ft-lbs (down)55.9 ft-lbs (cross) Allowable Bending Stress = 19.8 ksi 19.8 ksi Bending Stress on Column = 7.6 ksi 9.2 ksi Bending Stress OK Bending Stress OK Shelf Tab Connection - Moment From Post = 86.1 ft-lbs Short Direction Moment From Post = 39.7 ft-lbs Long Direction Shear on Tab = 355.1 lbs Short Direction Thickness of Tab = 0.075 in Shear on Tab = 378.5 lbs Long Direction Thickness of Tab = 0.090 in Depth of Tab = 0.375 in For Shear Allowable Shear Stress = 13.2 ksi Shear Stress on Tab = 12.7 ksi Shear Stress OK Worst Case Column Axial Calculations - Allowable Buckling Stress = 69.2 ksi Ω = 1.8 Elastic Flexural Buckling = 46.3 ksi Allowable Comp. Stress = 24.5 ksi Nominal Column Capacity = 6734 lbs Allowable Column Capacity = 3741 lbs Axial RMI LC #2 = 162 lbs Axial Load OK RMI LC #5 = N/A RMI LC #6 = 441 lbs - Down Aisle 732 lbs - Cross Aisle Critical Buckling Load = 20289 lbs Cm = 0.85 αx = 0.961 αy = 0.935 Combined Bending And Axial Forces - Axial Stress Unity = 0.118 Down 0.196 Cross Bending Stress Unity = 0.338 Down 0.421 Cross Combined Stress Unity = 0.616 Column is Adequate 8/15 Nordstrom Arcadia, California 91007 3/19/2024 RVC Overturning and Anti-Tip Calculations Overturning Forces - Total Weight = 509 lbs Load Case 1: Dead Load + 67% Live Load Total Lateral Force = 261 lbs Overturning Force = 1166 ft*lbs Controlling Overturning Force Total Weight = 288 lbs Load Case 2: Dead Load + 100% Top Shelf Total Lateral Force = 147 lbs Overturning Force = 856 ft*lbs Does Not Control Tension Force per Anchor = 488 lbs Shear Force per Anchor = 130 lbs Vertical Seismic Force = 57.6 lbs USE: Hilti Kwik Bolt TZ2 ANCHOR BOLTS Allowable Tension Force = 1154 lbs For 4000 Concrete Allowable Shear Force = 1657 lbs (2) 0.375in Diameter x 2.5in Embedment Overstrength Factor = 2.0 Combined Loading = 0.846 Floor Anchors are Adequate Steel Base Plate Design - 11ga Angle Clips Bolted to Post w/ 5/16" Bolt Tension Per Angle Clip = 488 lbs Thickness of Angle = 0.12 in Fy = 36 ksi Width of Angle = 1.5 in Fu = 65 ksi Moment Arm to Bolt = 1.375 in Gross Area of Clip = 0.176 in2 Ω, Yielding = 1.67 Net Area of Clip = 0.132 in2 Ω, Ultimate = 2 Allowable Tensile Strength = 3803 lbs Minimum of yielding in gross or fracture in the net section Bolt Connection Bearing Area = 0.023 in2 5/16" Bolt on Post Gauge Allowable Bearing Strength = 693 lbs Controlling Tensile Capacity = 693 lbs Base Plate Stress Unity = 0.70 Bending Stress OK 9/15 Nordstrom Arcadia, California 91007 3/19/2024 RVC Shelf Beam Calculations Type of Shelf Beam:Trimline_TFCV Steel Yield Stress = 33 ksi Shelf DL = 3.5 psf Modulus of Elast. = 29000 ksi Shelf LL = 7.5 psf Area of Beam = 0.170 in2 Beam Length = 4.0 ft Section Modulus of Beam = 0.024 in3 Beam Tributary = 0.5 ft Moment of Inertia of Beam = 0.017 in4 Allowable Load per Shelf = 30 lbs Shelf Distributed Load = 5.5 plf Distributed Load Allowable Bending Stress = 16.4 ksi (reduced for LTB) Allowable Shear Stress = 13.2 ksi Maximum Beam Moment = 11.0 ft-lbs Simple Span Maximum Design Shear = 11.0 lbs Beam Bending Stress = 5.43 ksi Beam Shear Stress = 0.06 ksi Bending Stress Unity = 0.332 Bending Stress OK Shear Stress Unity = 0.005 Shear Stress OK Max Allowable Deflection = 0.267 in L/180 Maximum Beam Deflection = 0.065 in Deflection OK 10/15 Nordstrom Arcadia, California 91007 3/19/2024 RVC Wall Supported Unit Calculations Seismic Force at Top of Units - Average Roof Height = 45.0 ft Height of Attachment = 26.3 ft Shear Coeff Boundaries = Vmin = 0.484 Vmax = 2.583 Design Base Shear Coeff = Vt = 0.625 Adjusted For ASD Total Weight per Unit = 217 lbs Lateral Force at Top/Bottom = 68 lbs Standard Stud Spacing = 16 in Wall Connections per Unit = 2 Load Shared w/ Adjacent Stud Connection from Nailer to Wall Framing: Tek Screw Capacity = 84 lbs Tension Cap. for #10 Screw in 20ga Stud Force Per Connection = 34 lbs Screw Capacity OK Connection from Post to Nailer: Wood Screw Capacity = 101 lbs Tension Cap. for #10 Screw to Nailer Force Per Connection = 68 lbs Screw Capacity OK Seismic Uplift Force on Each Shelf Seismic Uplift on Shelves - Vertical Seismic Component = 28.4 lbs Vertical Dead Load per Shelf = 88.0 lbs Connection Points per Shelf = 4.0 Each Corner Net Uplift Load per Shelf = -24.4 lbs Uplift Forcer per Connection = -6.1 lbs Rivet No Good 11/15 Nordstrom Arcadia, California 91007 3/19/2024 RVC Light Gage Steel Stud Wall Framing Stud Design Data - Height of Wall Studs = 16.0 ft Int. Non-Brg - Worst Case Ht Assumed Location of Point Load = 8.0 ft Design Lateral Load = 33.9 lbs From Shelving Unit Additional Lateral Load = 5.0 psf Minimum Interior Pressure Design Axial Load = 85.3 lbs Dead Load of Wall Framing Spacing of Studs = 16.0 in TRY: 3-5/8" x 1-5/8" x 20ga Studs @ 16" o.c. (Worst Case Assumed) Width = 3.625 in rx = 1.450 in Depth = 1.625 in ry = 0.616 in Thickness = 0.0312 in Sx = 0.304 in3 Fy =33 ksi Ix = 0.551 in4 E = 29000 ksi Ap = 0.262 in2 K =1.0 Unbraced Length X = 16 ft Unbraced Length Y = 1 ft Stud Capacity - Buckling Stress, X = 16.32 ksi Buckling Stress, Y = 754.22 ksi Allowable Buckling Stress = 16.32 ksi Nominal Axial Strength = 4277 lbs Factor of Safety = 1.92 Allowable Axial Load = 2228 lbs Maximum Design Moment = 348.9 ft-lbs Maximum Design Shear = 70.3 lbs Allowable Bending Stress = 21.78 ksi Actual Bending Stress = 13.77 ksi Bending Stress OK Allowable Shear Stress = 13.20 ksi Actual Shear Stress = 0.27 ksi Shear Stress OK Allowable Axial Stress = 8.50 ksi Actual Axial Stress = 0.33 ksi Axial Stress OK Combined Stress Unity = 0.67 Combined Stress OK 12/15 Nordstrom Arcadia, California 91007 3/19/2024 RVC Anchor Analysis:Second Floor Shelving Anchor Properties Anchor Mfg. =Hilti Anchor =Kwik Bolt TZ2 ESR -4266 Evaluation Service Report dia =0.375 in.Anchor Diameter hnom =2.500 in.Nominal Embedment hef =2.000 in.Effective Embedment Smin =3.50 in.Minimum Anchor Spacing f'c =4000 psi Concrete Compressive Strength Ω0 =2 Overstrength Factor SDC =D Seismic Design Category φseis =0.75 Seismic Reduction Factor for SDC C,D, or E Pu =1517 lbs.Ultimate Uplift per Anchor Group (LRFD) Vu =372 lbs.Ultimate Shear per Anchor Group (LRFD) Check For Anchor Strength - Uplift N =2 Number of Anchors in Group fya =100.9 ksi Min. Specified Yield Strength (Neck) futa =126.2 ksi Min. Specified Ultimate Tensile Strength (Neck) Ase,N =0.051 in.2 Effective Tensile Stress Area (Neck) Nsa =6490 lbs.Steel Strength in Tension φ =0.75 Strength Reduction Factor φNsa =4868 lbs.Factored Capacity per Each Anchor Nua =758 lbs.Ultimate Uplift per Anchor Nua / φNn =0.16 OK Utilization Such That φNsa ≥ Nua Check For Anchor Pullout - Uplift N =2 Number of Anchors in Group Np, cr =NA lbs.Pull Out Strength of a Single Anchor in Cracked Concrete Np =NA lbs.Adjusted Pull Out Strength for Cracked Concrete ψc,p =1 Modification Factor for Uncracked Concrete (ACI Sec. 17.4.3.6) φ =0.65 Strength Reduction Factor φNp,eq =NA lbs.Factored Pull Out Strength per Anchor Nua =758 lbs.Ultimate Uplift per One Anchor Nua / φNn =NA NA Utilization Such That φNp,eq ≥ Nua 13/15 Nordstrom Arcadia, California 91007 3/19/2024 RVC Anchor Analysis Cont.: Check For Concrete Breakout - Uplift kcr =21 Coeff. For Concrete Breakout Strength (ACI Sec. 17.4.2.2) λa =0.6 Modification Factor for Lightweight Concrete Nb =2254 lbs.Concrete Breakout Strength for a Single Anchor (ACI Eq. 17.4.2.2a) ANco =36.0 in.2 Projected Concrete Failure Area of a Single Anchor (ACI Eq. 17.4.2.1c) ANc =54.0 in.2 Projected Concrete Failure Area of an Anchor Group (ACI Sec. 17.4.2) Ncbg =3381 lbs.Nominal Concrete Breakout Strength of Bolt Group (ACI Eq. 17.4.2.1b) φ =0.65 Strength Reduction Factor φNcbg =1648 lbs.Factored Breakout Capacity of Bolt Group Nua,g =1517 lbs.Ultimate Uplift per Anchor Group Nua / φNn =0.92 OK Utilization Such That φNcbg ≥ Nua,g Check For Anchor Strength - Shear N =2 Number of Anchors in Group Vsa =3385 lbs.Nominal Shear Strength per Anchor φ =0.65 Strength Reduction Factor φVsa =2200 lbs.Factored Shear Strength per Anchor Vua =186 lbs.Ultimate Shear per Anchor Vua / φVn =0.08 OK Utilization Such That φVsa ≥ Vua Check For Concrete Pryout Strength - Shear N =2 Number of Anchors in Group Ncpg =3381 lbs.Nominal Concrete Breakout Strength of Bolt Group (ACI Eq. 17.4.2.1b) kcp =1 Coeff. For Pryout Strength (ACI Sec. 17.5.3.1) Vcpg =3381 lbs.Nominal Pryout Strength for Anchor Group (ACI Eq. 17.5.3.1b) φ =0.70 Strength Reduction Factor φVcbg =2367 lbs.Factored Pryout Strength of Bolt Group Vua,g =372 lbs.Ultimate Shear per Anchor Group Vua / φVn =0.16 OK Utilization Such That φVcbg ≥ Vua,g LRFD Interaction of Tension and Shear Loads Anchor Group Capacity: Nua / φNn =0.92 Max. Utilization for Tension (Uplift)1648 lbs Tension Vua / φVn =0.16 Max. Utilization for Tension (Shear)2367 lbs Shear Utilization =0.92 OK Max. Utilization for Combined Tension and Shear (ACI Section R17.6)(𝑁𝑢𝑎 𝜑𝑁𝑛)5/3+(𝑉𝑢𝑎 𝜑𝑉𝑛)5/3≤1.0 14/15 15/15