Loading...
HomeMy WebLinkAbout605 S Baldwin Ave #9 & 10 - 2024 -x x x x x x x x x x x x x x x x x x x x x x x x x x x x x REVISIONS BY REVISIONS BY REVISIONS BY REVISIONS BY        THESE CALCULATIONS ARE NOT VALID FOR SECURING A BUILDING PERMIT UNLESS STAMPED  AND SIGNED BY HANSEN‐HOKAMA, STRUCTURAL ENGINEERS.  HANSENHOKAMA STRUCTURAL ENGINEERS 180 E. Main St., Suite 201  Tustin, CA 92780  (714) 573‐0073  FAX (714) 573‐0688  Job No.               22‐18C Date              4/22/24  Page        1            STRUCTURAL CALCULATIONS   FOR REPAIR OF FIRE DAMAGES  AT:                                            THE CLARY APARTMENTS  605 S. BALDWIN AVE., UNITS 9 AND 10  ARCADIA, CALIFORNIA         THESE CALCULATIONS ARE NOT VALID FOR SECURING A BUILDING PERMIT UNLESS STAMPED  AND SIGNED BY HANSEN‐HOKAMA, STRUCTURAL ENGINEERS.  HANSENHOKAMA STRUCTURAL ENGINEERS 180 E. Main St., Suite 201  Tustin, CA 92780  (714) 573‐0073  FAX (714) 573‐0688  Job No.               22‐18C Date              4/22/24  Page        2     Building Codes – CHECK APPROPRIATE CODE    2022 California Building Code  2023 County of Los Angeles Building Code   2023 City of Los Angeles Building Code    STRUCTURAL MATERIAL SPECIFICATIONS  Typical unless noted otherwise in calculations    CONCRETE  –  f’c = 3,000 psi in 28 days minimum    REINFORCEMENT  –  ASTM A615, Grade 40 #4 bars and smaller, Grade 60 #5 bars and greater    MASONRY  –  Grade N Units:  f’m = 1,500 psi, n = 25.7    MISCELLANEOUS STEEL:       Structural  ASTM A36  Fy = 36 ksi       Pipes   ASTM A53  Fy = 35 ksi       Structural Tubes ASTM A500  Fy = 46 ksi       Bolts   ASTM A307  Loads per code    LUMBER:  Stress Graded Douglas Fir‐Larch (All stresses in psi)       Joists/Rafters  No. 1   Fb = 1,000, Fv = 180       4 x Sawn Beams No. 1   Fb = 1,000, Fv = 180         6 x Sawn Beams No. 1   Fb = 1,350, Fv = 170         Glu‐Lam Beams 24F   Fb = 2,400, Fv = 240        STRUCTURAL HARDWARE: Connectors specified for framing and anchorage shall be equal to  Simpson Company “Strong‐Tie”. Model numbers listed are Simpson’s but equivalent hardware  may be substituted with the approval of the building official.    SOIL BEARING VALUE:    N/A – Fire damage did not affect existing foundation/footings.            THESE CALCULATIONS ARE NOT VALID FOR SECURING A BUILDING PERMIT UNLESS STAMPED  AND SIGNED BY HANSEN‐HOKAMA, STRUCTURAL ENGINEERS.  HANSENHOKAMA STRUCTURAL ENGINEERS 180 E. Main St., Suite 201  Tustin, CA 92780  (714) 573‐0073  FAX (714) 573‐0688  Job No.               22‐18C Date              4/22/24  Page        3      DESIGN LOADS    ROOF LOADS   ROOFING 3.0  SHEATHING 2.5  RAFTERS 2.0  MISC. 0.5  DL =   8.0  psf  LL =   20.0  psf  TL =   28.0  psf  CEILING LOADS   JOISTS 2.0  INSULATION 1.0  DRYWALL 2.5  MISC. 0.5  DL =   6.0  psf  LL =   10.0  psf  TL =   16.0  psf      SUB‐FLOOR LOADS  FLOORING 3.0  SHEATHING 2.5  JOISTS 3.0  MISC. 1.5  DL =   10.0  psf  LL =   40.0  psf  TL =   50.0  psf                     THESE CALCULATIONS ARE NOT VALID FOR SECURING A BUILDING PERMIT UNLESS STAMPED  AND SIGNED BY HANSEN‐HOKAMA, STRUCTURAL ENGINEERS.  HANSENHOKAMA STRUCTURAL ENGINEERS 180 E. Main St., Suite 201  Tustin, CA 92780  (714) 573‐0073  FAX (714) 573‐0688  Job No.               22‐18C Date              4/22/24  Page        4    RAFTERS      SPAN = 11’‐6” MAX      w = 28 PSF x 2.0 = 56 PLF      M = 56 x 11.52/8 = 926 FT‐LBS     SM 1000 X 1.25 X 1.15 X 1.3 = 5.94 IN3 < = 7.56 IN3            (N) DF#1 2 X 6 AT 24”o.c.    HIP/VALLEY MEMBERS      SPAN =  12’‐9”      W = (28 PSF X 92)/2 = 1134 LBS      M = 0.128 X 12.75 X 1134 = 1850 FT‐LBS     SM 1000 X 1.25  X 1.2 = 14.8 IN3 < = 21.39 IN3            (N) DF#1 2 X 10 MEMBER    FLUSH BEAM UNDER HIP/RIDGE BRACE      SPAN = 13’‐6” MAX      P = 2[2/3(1134)] + [(6.75 X 28)4/2] = 1512 LBS      M = (1512)(4)(9.5)/13.5 = 4256 FT‐LBS     SM 1000 X 1.2 X  1.25  = 34.04 IN3 < =  49.91 IN3            (N) DF#1 4 X 10 FLUSH BEAM                THESE CALCULATIONS ARE NOT VALID FOR SECURING A BUILDING PERMIT UNLESS STAMPED  AND SIGNED BY HANSEN‐HOKAMA, STRUCTURAL ENGINEERS.  HANSENHOKAMA STRUCTURAL ENGINEERS 180 E. Main St., Suite 201  Tustin, CA 92780  (714) 573‐0073  FAX (714) 573‐0688  Job No.               22‐18C Date              4/22/24  Page        5    CEILING JOISTS      SPAN = 12’‐0” MAX      w = 16 PSF x 1.33 = 22 PLF      M = 22 x 122/8 = 396 FT‐LBS     SM 1000 X 1.15 X 1.3 = 3.17 IN3 < =7.56 IN3            (N) DF#1 2 X 6 AT 16”o.c.  HEADER #1      SPAN = 10’‐0” MAX    P = 1512 (4/13.5) = 448 LBS    w = 28 (9/2) + 6 (13.5/2) = 167 PLF       M = (448 x 10/4) + (167 x 102/8)  = 3207 FT‐LBS     SM 1000 X 1.25 X 1.3 = 23.68 IN3 < = 30.66 IN3            (N) DF#1 4 X 8 HEADER (MIN)  HEADER #2     SPAN = 6’‐0” MAX    w = 28 (9/2)  = 126 PLF       M = 126 x 62/8  = 567 FT‐LBS     SM 1000 X 1.25 X 1.3 = 4.18 IN3 < = 17.65 IN3            (N) DF#1 4 X 6 HEADER               THESE CALCULATIONS ARE NOT VALID FOR SECURING A BUILDING PERMIT UNLESS STAMPED  AND SIGNED BY HANSEN‐HOKAMA, STRUCTURAL ENGINEERS.  HANSENHOKAMA STRUCTURAL ENGINEERS 180 E. Main St., Suite 201  Tustin, CA 92780  (714) 573‐0073  FAX (714) 573‐0688  Job No.               22‐18C Date              4/22/24  Page        6    SUB‐FLOOR JOISTS     SPAN = 6’‐0” MAX      w = 50 PSF x 1.33 = 67 PLF      M = 67 x 62/8 = 302 FT‐LBS     SM 1000 X 1.15 X 1.3 = 2.42 IN3 < =7.56 IN3            (N) DF#1 2 X 6 AT 16”o.c.  SUB‐FLOOR GIRDER     SPAN = 7’‐0” MAX    w = 50 PSF X 6  = 300 PLF       M = 300 x 72/8  = 1837 FT‐LBS     SM 1000  X 1.3 = 16.95 IN3 < = 17.65 IN3            (N) DF#1 4 X 6 GIRDER            THESE CALCULATIONS ARE NOT VALID FOR SECURING A BUILDING PERMIT UNLESS STAMPED  AND SIGNED BY HANSEN‐HOKAMA, STRUCTURAL ENGINEERS.  HANSENHOKAMA STRUCTURAL ENGINEERS 180 E. Main St., Suite 201  Tustin, CA 92780  (714) 573‐0073  FAX (714) 573‐0688  Job No.               22‐18C Date              4/22/24  Page        7      LATERAL ANALYSIS    THE SUBJECT BUILDING HAS BEEN DETERMINED TO HAVE SUSTAINED “LESS THAN  SUBSTANTIAL STRUCTURAL DAMAGE” THEREFORE IN ACCORDANCE WITH THE 2022  CALIFORNIA EXISTING BUILDING CODE, SECTION 405.2.1, THE DAMAGED ELEMENTS SHALL BE  PERMITTED TO BE RESTORED TO THEIR PREDAMAGE CONDITION. NEW STRUCTURAL MEMBERS  AND CONNECTIONS USED FOR THIS REPAIR SHALL COMPLY WITH THE 2022 CALIFORNIA  BUILDING CODE FOR NEW BUILDINGS OF A SIMILAR STRUCTURE, PURPOSE AND LOCATION.