HomeMy WebLinkAbout11818 Clark St - 2024 -SHEET INDEX E000 E001 E100 E200 TE00 ELECTRICAL SPECIFICATIONS (AS APPLICABLE)ELECTRICAL SYMBOLS LIST WALLCLG.DESCRIPTIONFLR. DUPLEX RECEPTACLE AT +15" FOR WALL MOUNTED U.O.N. DOUBLE DUPLEX RECEPTACLE AT + 15" FOR WALL MOUNTED U.O.N. DUPLEX RECEPTACLE WITH USB 2.0 PORT GROUND CONNECTOR MAIN SWITCHBOARD OR POWER DISTRIBUTION BOARD. VERIFY DIMENSION WITH VENDER/MANUFACTURER. ELECTRICAL PANEL. REFER TO PANEL SCHEDULE FOR DETAILS. INDICATES PLAN NOTE NUMBER "1", SEE PLAN JUNCTION BOX CONDUIT STUB OUT, 3/4" MINIMUM - SEE PLANS FOR NOTES CONDUIT CONCEALED ABOVE CEILING OR IN WALLS HOMERUN TO PANEL "A", CIRCUITS #1A-1 SPECIAL NEMA RECEPTACLE. SEE EQUIPMENT PLAN/INSTALLATION MANUAL FOR SPECS AND DETAILS. COMBINATION TELEPHONE, DATA AND CABLE OUTLET AT +18" U.O.N. PROVIDE 1/2"C.O. STUBBED TO ACCESSIBLE CEILING SPACE TELEPHONE OUTLET; CAT5E CABLE. RJ11 TERMINATION MOUNTED AT +18" PROVIDE 1/2"C.O. STUBBED TO ACCESSIBLE CEILING SPACE DATA OUTLET; CAT5E CABLE, RJ45 TERMINATION MOUNTED AT +18" U.O.N. PROVIDE 1/2"C.O. STUBBED TO ACCESSIBLE CEILING SPACE CABLE OUTLET; RG-6 COAXIAL CABLE. MOUNTED AT +18" U.O.N. PROVIDE 1/2"C.O. STUBBED TO ACCESSIBLE CEILING SPACE LIGHTING FIXTURE WITH 90 MIN. EMER. BATTERY PACK OR ON INVERTER SEE LIGHT FIXTURE SCHEDULE FOR DETAILS AND SPECS DENOTES EQUIPMENT #1, SEE EQUIPMENT SCHEDULE FOR THE DETAILS AND EXACT SPECIFICATIONS. DENOTES MECHANICAL EQUIPMENT #1 SEE MECHANICAL DRAWINGS FOR THE DETAILS AND SPECIFICATIONS. SINGLE POLE SWITCH AT 48" U.O.N. DIMMER SWITCH/DIMMING WALL CONTROL STATION AT +48" U.O.N. THREE-WAY SWITCH AT +48" U.O.N. THREE-WAY DIMMER SWITCH AT +48" U.O.N. MANUAL MOTOR STARTER VS DL S/C MOTOR OUTLET - IDENTIFICATION ABBREVIATION FOR NEW / EXISTING / RELOCATED SYMBOL NOTES: NON-FUSED/FUSED SWITCH, SIZE AS SHOWN IN THE PLAN OS GAS SOLENOID-SEE PLUMBING PLAN FOR EXACT LOCATION. (N) / (E) / (R) OCCUPANCY AUTOMATIC WALL SWITCH SENSOR WITH SINGLE LEVEL SWITCHING AT +48" U.O.N./MANUFACTURER TO BE DETERMINED VACANCY AUTOMATIC WALL SWITCH SENSOR WITH SINGLE LEVEL SWITCHING AT +48" U.O.N./MANUFACTURER TO BE DETERMINED OCCUPANCY SENSOR SINGLE POLE SWITCH WITH DIMMER CONTROL FEATURE AT +48" U.O.N./MANUFACTURER TO BE DETERMINED CEILING MOUNTED DAYLIGHT SENSORMANUFACTURER TO BE DETERMINED TIME CLOCK WITH MANUAL BY-PASS SWITCH SEE LIGHTING CONTROL DIAGRAM FOR DETAILS S C TC F M ELECTRICAL SPECIFICATION SINGLE LINE DIAGRAM/ SCHEDULES LIGHTING PLAN POWER PLAN TITLE24 - INDOOR D D OS VS OS/D J J J S S S 3 3 S EXHAUST AIR GRILLE - REFER TO MECHANICAL PLAN 1 5.UNLESS OTHERWISE NOTED ON DRAWINGS OR OTHERWISE REQUIRED BY THE NATIONAL ELECTRICAL CODE, HANDICAP CODES OR LOCAL CODES, OUTLET HEIGHTS SHALL BE AS FOLLOWS: 3. 4. 6. 7. 5. 8. 9. 10. 120/208 VOLT SYSTEMNEUTRAL - WHITEPHASE A OR L1 - BLACKPHASE B 0R L2 - REDPHASE C OR L3 - BLUEGROUND - GREEN FINAL CONNECTIONS INTO AND OUT OF THE TRANSFORMER. FINAL CONNECTIONS WHERE RIGID CONDUIT IN NOT PRACTICAL. FINAL CONNECTIONS TO VIBRATING EQUIPMENT. FINAL CONNECTIONS TO MOTORS. IN WALLS (FOR LIGHT SWITCHES AND 120 VOLT POWER RECEPTACLES AND HVAC CONTROL EQUIPMENT). INTER-CONNECTIONS BETWEEN ALL LIGHT FIXTURES AND HOMERUNS TO PANELS WHERE CODE ALLOWS. THE USE OF ROMEX, BX, ETC. IS PERMITTED ONLY IN RESIDENTIAL CONSTRUCTION NOT HIGHER THAN THREE STORIES. ALL WIRING TO BE COLOR-CODED AS FOLLOWS: ON ALL 20 AMP BRANCH CIRCUITS, CONDUCTORS LARGER THAN #10 AWG SHALL BE REDUCED TO #10 AWG WITHIN10 FEET OF PANEL BOARD AND DEVICE IN JUNCTION BOXES ON RATED TERMINAL STRIPS. CONDUCTORS MAY BE STRANDED FOR SIZES #10 AWG AND LARGER. CONDUCTORS SIZE #12 SHALL BE SOLID (NOTSTRANDED). ALUMINUM CONDUCTORS ARE NOT PERMITTED, EXCEPT AT SERVICE ENTRANCE, WHERE REQUIRED BY LANDLORD. CONDUCTOR CONNECTION MUST BE PER MANUFACTURER'S REQUIREMENTS. CONTRACTOR MUST OBTAIN WRITTENPERMISSION FROM GENERAL CONTRACTOR AND PROJECT MANAGER WHEN USED. ALL WIRING (120V AND ABOVE) SHALL BE IN CONDUIT, UNLESS SPECIFICALLY NOTED OTHERWISE. ALL LOWVOLTAGE WIRING CONDUIT REQUIREMENTS TO BE COORDINATED WITH OWNER. THE USE OF SHARED NEUTRALS IS REQUIRED FOR LIGHTING CIRCUITS AND SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND LOCAL CODES. ALL OTHER EQUIPMENT REQUIRING A NEUTRAL CONDUCTOR SHALL HAVE A DEDICATED FULL SIZE NEUTRAL. WIRE CONNECTORS SHALL BE EQUAL TO "SCOTCH LOCK" FOR #8 AWG WIRE AND SMALLER AND EQUAL TO T & B"LOCKTIGHT" FOR #6 AWG AND LARGER. 277/480 VOLT SYSTEMNEUTRAL - GRAYPHASE A OR L1 - BROWNPHASE B 0R L2 - ORANGEPHASE C OR L3 - YELLOWGROUND - GREEN WITH YELLOW TRACER A. 2. a. b. c. d. PHASING REQUIREMENTSJ. 1. 1. DEMOLITION 2. K. THIS CONTRACTOR IS TO INCLUDE IN HIS BID ALL NECESSARY SERVICE REQUIRED TO KEEP THE OPERATING PHASE OF THE STORE'S ELECTRICAL SERVICE IN OPERATION. CONTRACTOR MUST SCHEDULE IN WRITING WITH TENANT/ARCHITECTS AND THE LANDLORD ONE WEEK PRIOR TO ANY SHUT DOWN OF THE ELECTRICAL SYSTEM. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK ANDTHE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR. COORDINATE WITH THE GENERAL CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. SECTION 16000 DIVISION 16 - ELECTRICAL 1. 2. NOTEA. BASIC ELECTRICAL REQUIREMENTS 4. 3. 5. 1. B.GENERAL REQUIREMENTS 2. 3. 5. 4.ALL WORK IN THIS SECTION SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABORCALLED FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH.ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS,BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE FURNISHED AND INSTALLED AS PART OF THE CONTRACT. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION,INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE ELECTRICAL SYSTEM AS SHOWN ON THEDRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR ARCHITECTS SHALL BE PROVIDED BY THIS CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AND ARCHITECTS, AS REQUIRED. REFER TO RESPONSIBILITY SCHEDULE FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMSWHICH MAY AFFECT THE BID. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY DISCREPANCIES OR ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSEDSUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTORS BID. SUBMITTAL OF BIDSHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH AREREQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOTRELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF HIS WORK. THIS ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THIS WORK TO COMPLY WITH TENANT/ARCHITECT'S SCHEDULE AND THE PROJECT COMPLETION DATE. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THEWORK OF HIS SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTORS RESPONSIBILITY TOPROVIDE HIS SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONSAND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 16. 2. d. c. 4. 5. SLEEVES 1. 2. HANGERS 3. M. L. 1. 2. 1. 3. FINAL ELECTRICAL INSPECTIONSN. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, TENANT/ARCHITECTS MAY HAVE AN INDEPENDENTELECTRICAL CONTRACTOR INSPECT THE FINISHED ELECTRICAL INSTALLATION UPON COMPLETION FORCOMPLIANCE WITH THE PLANS, SPECIFICATIONS AND CODES. THE INSTALLING CONTRACTOR WILL BE RESPONSIBLETO BRING ALL ITEMS REPORTED BY THE INDEPENDENT ELECTRICAL CONTRACTOR UP TO PLANS ANDSPECIFICATION REQUIREMENTS. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DIELECTRICALLY SEPARATED. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGINGFROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHEREINTERFERENCES OCCUR, AND IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALLTRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITHACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS AREALSO SUBJECT TO LANDLORD CRITERIA. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C-CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPEFINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND/OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACHSLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITHEACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR.CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS INMASONRY FLOORS OR WALLS. a. 6. END OF SECTION 16000 6. 7. 1. 8. C. 2. TEMPORARY LIGHT AND POWER 1. CODESD. 1. E. 2. F.TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS LICENSES, PERMITS, INSPECTIONS & FEES 1. 2. ALL WORK SHALL CONFORM TO THE LANDLORD'S CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES ANDORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODESAND REQUIREMENTS. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS AWARDED, CHANGE ORDERS FOR INCREASED COSTS DUE TO CODE ISSUES WILL NOT BE ACCEPTED BY OWNER, UNLESS ALLOWANCES HAVE PREVIOUSLY BEEN AGREED UPON. GENERAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO ARCHITECTS/ENGINEERS FORAPPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FORARCHITECTS/ENGINEERS REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS.SUBMITTALS SHALL BEAR THE STAMP AND/OR THE SIGNATURE OF THE GENERAL CONTRACTOR AND THESUB-CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BYARCHITECTS/ENGINEERS THROUGH SHOP DRAWING SUBMITTAL PROCESS FOR ACCEPTANCE PRIOR TOINSTALLATION. THE USE OF ANY UNATHORIZED EQUIPMENT SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE. FURNISH TO ARCHITECTS ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OFPROJECT. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO HIS WORK. THE ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETEAND OPERATING SYSTEM. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING AND CHANNELING REQUIRED FOR ANY WORK UNDER THISDIVISION. CUTTING SHALL HAVE PRIOR APPROVAL BY THE ARCHITECTS AND THE LANDLORD. ALL PATCHING SHALLBE BY G.C. AND SHALL MATCH THE SURROUNDING SURFACES. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL TEMPORARY WIRING AND RELATED GROUND FAULT INTERRUPTION PROTECTION FOR LIGHT AND POWER FOR ALL CONTRACTORS AND SHALL BE RESPONSIBLE FORTHE REMOVAL OF ALL TEMPORARY WIRING. THE GENERAL CONTRACTOR SETS UP ALL ELECTRICAL UTILITIES IN THE NAME OF THE TENANT. TENANT PAYS FORALL UTILITIES THROUGHOUT CONSTRUCTION. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD CONSTRUCTION PRACTICES. THIS CONTRACTOR SHALL INCLUDE, AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTINGELECTRICAL EQUIPMENT, CONDUITS, ETC. NOT TO BE REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTEDOTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT PRIOR TO REMOVAL. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND ROOF/WALL/FLOOR PATCHED/REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED CONDUIT OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED CONDUIT MUST BE REMOVED TO POINT OF ORIGIN. CONFIRMTHE EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN BID PROPOSAL.FLEXIBLE METAL CONDUIT OR MC TYPE CABLE: GENERALLY, ALL CONDUIT SHALL BE CONCEALED EXCEPT FOR UNFINISHED AREAS, SUCH AS EQUIPMENT ROOMS.EXPOSED CONDUIT SHALL BE ALLOWED ONLY AS NOTED ON PLAN AND AS APPROVED BY PROJECT MANAGER.PAINTING OF CONDUITS, NOTED ON DRAWINGS OR SPECIFICATIONS WILL BE BY GENERAL CONTRACTOR. A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM INCLUDING THE INSTALLATION OF SAFETY AND DISCONNECTSWITCHES, MOTOR STARTERS AND LIGHTING. IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TOINCLUDE IN HIS BID FOR PROVIDING SERVICE EQUIPMENT NECESSARY FOR TIE-IN TO LANDLORD'SDISTRIBUTION EQUIPMENT OR TO OBTAIN SERVICE FROM LOCAL UTILITY COMPANY. REFER TO ELECTRICAL RESPONSIBILITY SCHEDULE AND ELECTRICAL POWER RISER DIAGRAM FOR ADDITIONAL INFORMATION. ALL CONDUITS SHALL BE GALVANIZED IMC OR EMT UNLESS OTHERWISE SPECIFIED IN SPECIFICATIONS OR ONDRAWINGS. ALL CONDUIT IS TO BE UL LABELED. EMT CONNECTORS SHALL BE STEEL COMPRESSION OR SET SCREWTYPE. CONDUIT UNDER SLAB ON GRADE SHALL BE RIGID STEEL, OR SCHEDULE 40 PVC WITH RIGID STEEL ELLSWHERE PERMITTED BY LANDLORD OR CODE. EMT FOR WET LOCATIONS TO BE PERMITTED ONLY WHEN ALLSUPPORTS, BOLTS, STRAPS, SCREWS AND SO FORTH ARE CORRISION-RESISTANT MATERAILS PER 358.10. ALL IN/UNDER FLOOR CONDUIT SHALL BE OF MINIMUM 3/4" SIZE. IF HVAC CONTROL WIRING IS REQUIRED TO BE RUN IN CONDUIT, IT SHALL BE A MINIMUM OF 3/4", UNLESSNOTED OTHERWISE ON DRAWINGS. SUPPORT ALL CONDUIT, INCLUDING SEISMIC AND SWAY BRACING, IN ACCORDANCE WITH THE NEC AND LOCALCODES. THE WIRING OF MECHANICAL EQUIPMENT AS OUTLINED ON THE BID SET DRAWINGS AND IN THESPECIFICATIONS. WORK SHALL INCLUDE WIRING OF ALL STARTERS, DISCONNECTS, AND POWER WIRING OFMECHANICAL EQUIPMENT EXCEPT AS SPECIFICALLY NOTED OTHERWISE. ALL LOW VOLTAGE (24 VOLT) EMSTEMPERATURE CONTROL WIRING SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR UNLESSNOTED SPECIFICALLY ON DRAWING. METERING AND CURRENT TRANSFORMERS AS REQUIRED BY DRAWINGS, UTILITY COMPANY, AND/OR LANDLORD. CONTRACTOR MUST ALSO INCLUDE IN BID ALL NECESSARY MATERIALS REQUIRED TO COMPLETE THE SYSTEM INCLUDING, BUT NOT LIMITED TO, FEEDERS, BRANCH CIRCUITS, JUNCTION BOXES, OUTLET BOXES, WIRING DEVICES, COVER PLATES, CONDUITS, ETC. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION,AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION,COMPLETION AND TESTING OF ALL THE WORK FOR THE ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS,CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TOTHE FOLLOWING: CONTRACTOR NOTES 2. 6. 5. 4. 3. FLEXIBLE CONDUIT OR MC TYPE CABLE SHALL BE USED FOR THE FOLLOWING APPLICATIONS ONLY: 1. 1. GUARANTEEG. THE EQUIPMENT MANUFACTURER SHALL PROVIDE A 12 MONTH GUARANTEE TO TENANT FROM THE DATE OFACCEPTANCE. THIS CONTRACTOR SHALL WARRANTY THE INSTALLATION OF THIS EQUIPMENT AND WILL BERESPONSIBLE FOR ANY DAMAGE AND/OR MALFUNCTION CAUSED BY THE INSTALLATION. THIS CONTRACTOR SHALLNOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM. b. c. d. 7. 8. 9. 10. 1. OUTLET BOXESC. 2. 4. 3. ALL CONDUITS MUST BE SIZED PER NEC AND LOCAL CODES. ALL SENSORMATIC WIRING MUST BE PLACED IN CONDUIT (PVC PIPE NOT PERMITTED). EXTERIOR BOXES SHALL BE CAST RUST-RESISTING METAL WITH GASKETED COVERS. PROVIDE PULL-WIRE IN ALL EMPTY CONDUITS EXCEPT AS NOTED OTHERWISE ON DRAWINGS. HOME RUNS AND MAIN CONDUIT RUNS ARE TO BE HELD TIGHT TO STRUCTURE ABOVE OR AS REQUIRED TO ALLOWPROPER SERVICE ACCESS AND OTHER TRADES WORK. CONDUIT MUST BE TRAPEZED TO ALLOW 3 FEET MINIMUM CLEARANCE ABOVE CEILING. ALL OUTLET BOXES SHALL BE GALVANIZED PRESSED STEEL OF THE STANDARD KNOCKOUT TYPE. NO ROUNDOUTLET BOXES SHALL BE PERMITTED UNLESS INDICATED AND FOR LIGHTING THAT REQUIRE SUCHCONFIGURATION. CONCEALED BOXES SHALL NOT BE LESS THAN 4" SQUARE AND 1 1/2" DEEP, WITH PLASTER RINGS. ALL KNOCKOUT BOXES, UPON WHICH LIGHTING FIXTURES ARE TO BE INSTALLED, SHALL BE EQUIPPED WITH 3/8"FIXTURE STUDS. INSTALL BOXES RIGIDLY FROM BUILDING STRUCTURE AND SUPPORT INDEPENDENTLY OF THE CONDUIT SYSTEM. ALSO PROVIDE SUITABLE BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES OF FLOORS, CEILINGS, WALLS ETC. ALL OUTLET BOXES TO BE PROVIDED WITH CADDY "QUICK-MOUNT BOX SUPPORT" TO MINIMIZE THE DEFLECTION THAT OCCURS WHEN PLUGGING/UNPLUGGING INTO THESE DEVICES. FLEXIBLE METAL CONDUIT OR MC TYPE CABLE MUST BE THE SAME SIZE AS THE IMC OR EMT CONDUIT TO WHICH IT IS CONNECTED. BOTH THE FLEXIBLE METAL CONDUIT AND IT'S FITTINGS ARE TO BE LISTED FOR GROUNDING. A GREEN GROUNDING CONDUCTOR SHALL BE INSTALLED. ALL CONNECTORS ARE TO BE OF A NEMA APPROVED TYPE. THE USE OF ROMEX, BX, ETC. IS PERMITTED ONLY IN RESIDENTIAL CONSTRUCTION NOT HIGHER THAN THREE STORIES. CONNECTION TO ANY OUTDOOR EQUIPMENT MUST BE WEATHERPROOF. 1. c. b. a. RECORD DRAWINGSH. THIS CONTRACTOR SHALL MAINTAIN ONE SET OF DRAWINGS ON THE JOB SITE UPDATED WEEKLY TO RECORD ALLDEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: REVISIONS, ADDENDUMS, AND CHANGE ORDERS. LOCATION OF CONCEALED CONDUIT AND EQUIPMENT. 2. 1. DISCREPANCIES IN DOCUMENTSI. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THIS CONTRACTOR SHALL MAKE ANY FINALCORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. FAILURE TOKEEP THESE RECORDS WILL ALLOW TENANT/ARCHITECTS TO DIRECT THE GENERAL CONTRACTOR TO PROVIDE THESE RECORDS AT HIS EXPENSE PRIOR TO FINAL PAYMENT. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE ELECTRICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING, PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE PROJECT MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, TENANT/ARCHITECT'SINTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONALCOMPENSATION PERMITTED. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS,AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. e. g. f. h. i. k. j. l. n. 3. a. b. 4. m. TELEPHONE INSTRUMENTS AND WIRING UNLESS NOTED OTHERWISE. AS-BUILTS, PANEL DESCRIPTION AND CIRCUIT BREAKER SPECIFIC LABELING. THE FOLLOWING ITEMS OF ELECTRICAL CONSTRUCTION ARE NOT INCLUDED IN THIS CONTRACT: BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, FIRE PROTECTION, MECHANICAL AND PLUMBING PLANS, SHOP DRAWINGS AND SPECIFICATIONS TO SEQUENCE,COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE ELECTRICAL SYSTEM, MATERIALS AND EQUIPMENTWITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. DATA CABLE WIRING UNLESS NOTED OTHERWISE. INSTALLATION OF CONDUITS STUBBED TO ABOVE CEILING FOR HVAC. ALSO, ANY ADDITIONAL CONDUIT FOR HVAC CONTROL EQUIPMENT WHERE PLENUM RATED CABLES ARE NOT PERMITTED. SMOKE/FIRE ALARM WIRING, DEVICES AND CONDUIT, AS SHOWN OR DESCRIBED ON DRAWINGS OR AS NECESSARY TO MEET LANDLORD, STATE, LOCAL, INSURANCE AND FIRE DEPARTMENT REQUIREMENTS. IF INDICATED ON DRAWINGS, INSTALLATION AND WIRING OF SPEAKERS, AMPLIFIERS, CONDUIT AND FINAL CONNECTIONS FOR SOUND SYSTEM AS SHOWN. FINAL CONNECTIONS TO ALL SIGNS, CORNICE LIGHTING, CASE LIGHTING, ETC. AS SHOWN ON DRAWINGS. TEMPORARY SERVICE AS INDICATED IN THE SPECIFICATIONS, INCLUDING ITS REMOVAL. A COMPLETE EMERGENCY AND EXIT LIGHTING SYSTEM AS SHOWN ON THE DRAWINGS. A COMPLETE CONDUIT SYSTEM FOR TELEPHONE/DATA INCLUDING BRANCH CONDUITS, OUTLET BOXES, PULL WIRES, GROUND CONDUCTORS, COVER PLATES, ETC. OR AS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. INSTALLATION OF LIGHT FIXTURES AND LAMPS AS SHOWN ON THE DRAWINGS INCLUDING ALL DEVICES,EQUIPMENT, ETC. REQUIRED FOR MOUNTING. BALANCING LOADS. 1. B. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUITS SERVING ALL EQUIPMENT, INCLUDING BUT NOTLIMITED TO, LIGHTING, RECEPTACLES, HEATING, AIR CONDITIONING, PLUMBING EQUIPMENT, TELEPHONE, DATA,SPEAKERS, SECURITY, PAGER, TRAFFIC COUNTING SYSTEM AND ELECTRICAL EQUIPMENT. CONDUIT b. a. c. 1. 2. D.JUNCTION AND PULL BOXES CONVENIENCE OUTLETS: BOXES AND COVERS SHALL BE GALVANIZED STEEL OF CODE GAUGE SIZE. THE PLANS INDICATE ONLY SCHEMATIC ROUTINGS FOR CONDUIT RUNS. THIS CONTRACTOR SHALL FURNISH AND INSTALL ADDITIONAL BOXES WHERE REQUIRED BY FIELD CONDITIONS OR BY CODE. MOUNTED ON WALL NO MORE THAN 48-INCHES, MEASURED FROM TO TOP OF THE RECEPTACLE OUTLET BOXOR RECEPTACLE HOUSING AND; NO LESS THAN 15-INCHES, MEASURED FROM THE BOTTOM OF THERECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING, TO THE LEVEL OF THE FINISHED FLOOR OR WORKING PLATFORM UNLESS OTHERWISE INDICATED OR HORIZONTALLY MOUNTED IN BASEBOARD BENEATH CABINETS, AS SHOWN ON DRAWINGS, OR AS REQUIRED BY LOCAL CODES, SEE DRAWINGS. SWITCH HEIGHT 48" FROM FINISHED FLOOR TO TOP OF OUTLET. TELEPHONE OUTLETS SHALL BE LOCATED AS NOTED ON DRAWINGS. 4. 3. WIRING 5. E. 1. 2. b. a. #10 BETWEEN 100-150 FEET #12 LESS THAN 100 FEET d. c. #6 OVER 250 FEET #8 BETWEEN 150 - 250 FEET INSTALL BOXES RIGIDLY SUPPORTED FROM THE BUILDING STRUCTURE AND SUPPORTED INDEPENDENT OF THE CONDUIT SYSTEM. ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHOULD BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. JUNCTION AND PULL BOXES MUST BE LABELED WITH CIRCUIT NUMBER IDENTIFICATION AND SYSTEM TYPE ON COVER. CONDUCTORS FOR FEEDERS AND BRANCH CIRCUITS SHALL BE COPPER AND THE AWG SIZE AND TYPE AS SHOWN ON DRAWINGS. MINIMUM WIRE SIZE #12. THE CONDUCTORS SHALL BE 600 VOLT INSULATION, TYPE THW, THWN OR THHN. MINIMUM WIRE SIZE - 20 AMP BRANCH CIRCUIT SHALL BE AWG LISTED SIZE PER DISTANCE SHOWN BELOW.DISTANCE SHALL BE MEASURED FROM THE PANELBOARD CIRCUIT BREAKER TO THE FURTHEST OUTLET. 3. b. a. 1/2" FOR INDIVIDUAL LIGHTING FIXTURE CONNECTIONS OR TO INDIVIDUAL LIGHT SWITCHES (IF ACCEPTABLE BY THE LANDLORD AND LOCAL CODE OFFICIALS) AND 3/4" FOR ALL OTHER LOCATIONS. MAIN FEEDER CONDUIT 2" OR LARGER FOR ALL APPLICATIONS. MINIMUM SIZE OF CONDUIT SHALL BE: 1.IT IS CONTRACTOR/ELECTRICIANS' RESPONSIBILITY TO FIELD VERIFY ACTUAL SITE CONDITION AND SHALL NOTIFYEOR(S) ANY DISCREPANCIES WITH THE PLAN THAT IMPACTS ON THE BID PRIOR TO BIDDING. SCOPE OF WORK ·EXISTING COMMERCIAL TENANT IMPROVEMENT. ·PROVIDE NEW LIGHTING FIXTURES/CONNECTIONS TO THE RENOVATED AREAS. ·PROVIDE NEW POWER FIXTURES/CONNECTIONS TO THE RENOVATED AREAS. ·EXISTING MAIN SERVICE AND SERVICE/DISTRIBUTION EQUIPMENT TO BE UTILIZED. CEILING MOUNTED OCCUPANCY SENSOR MANUFACTURER TO BE DETERMINED CEILING MOUNTED VACANCY SENSOR MANUFACTURER TO BE DETERMINED SYMBOL LIST SHOW IN FOR GENERAL REFERENCE ONLY. A PRESENCE OF A SYMBOL DOES NOT IMPLY ITS USE ON THIS PROJECT. REFER TO DRAWING FOR SPECIFIC SYMBOLS USED. HARD WIRED, WITH BATTERY BACKUP, SMOKE DETECTOR/CARBON MONOXIDE DETECTOR/MULTI-PURPOSE CARBON MONIXIDE & SMOKE DETECTOR. GROUND FAULT INTERRUPTING PROTECTED CIRCUIT DUPLEX RECEPTACLEPROVIDE GFCI BREAKER INSTEAD OF GFCI OUTLET AS NECESSARY RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 1/16/2024 5:40:01 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: N.T.S. E000 ELECTRICAL SPECIFICATION J.L.K.T OVERRIDE SWITCH TO LIGHTS TO LIGHTSA-30 A-32 TIME CLOCK 120V AC 2-HOUR TIMER SWITCH LIGHTING CONTROL DIAGRAM A-34 TO SIGNAGE LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION LAMP VOLT WATT L1 2X4 RECESSED LED TROFFER LIGHT, DIMMABLE LITHONIA 2GTL4 SERIES OR APPROVED EQUAL LED 120 43 L2 LED RECESSED DOWNLIGHT, DIMMABLELITHONIA LDN6 SERIES OR APPROVED EQUAL LED 120 18 EMX COMBINATION EMERGENCY LED LIGHT/EXIT SIGN 90 MINUTES BATTERY PACK LITHONIA ECC SERIES OR EQUIVALENT --- 120 --- EM EMERGENCY LED LIGHT WITH 90 MINUTES BATTERY PACKLITHONIA EU2L (WALL), ELR2 (CEILING), ELAQWP (OUTDOOR) SERIES OR EQUIVALENT --- 120 --- EE LIGHT FIXTURE WITH 90 MINUTES EMERGENCY BATTERY PACKVERIFY WITH MANUFACTURER FOR OPTION/INVERTER IF NOT AVAILABLE ---120 --- X LED EXIT SIGN WITH 90 MINUTES BATTERY PACKLITHONIA EXR LED M6 OR EQUIVALENT ---120 --- 120V, SINGLE POLE, MAX 3% VOLTAGE DROP LENGTH OF RUN COPPER COPPER COPPER COPPER COPPER ALUMINUM ALUMINUM AMP LOAD200'150'100'50'25' 14 12 10 1 1/0 3/0 250 12 12 10 1 1/0 3/0 250 10 8 6 1 2/0 3/0 300 8 6 4 2/0 4/0 300 600 6 4 4 4/0 300 500 900 15 AMP 20AMP 30 AMP 100 AMP 100 AMP 200 AMP 200 AMP NOTE:THE MAXIMUM COMBINED VOLTAGE DROP ON BOTH INSTALLED FEEDER CONDUCTORS AND BRANCH CIRCUITCONDUCTORS TO THE FARTHEST CONNECTED LOAD OR OUTLET SHALL NOT EXCEED 5 PERCENT. EMERGENCY EXIT ILLUMINATION NOTES 1. FIXTURES WITH 90 MIN. EMERGENCY BATTERY BACKUP SHALL BE WIREDAHEAD OF ANY CONTROL IN COMPLIANCE WITH [2022 CEC 700.12(I)(2)(3)(A)]. 2. THE MEANS OF EGRESS SERVING A ROOM OR SPACE SHALL BE ILLUMINATEDAT ALL TIMES THAT THE ROOM OR SPACE IS OCCUPIED. [2022 CBC 1008.2] 3. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATIONOF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGEBATTERIES, UNIT EQUIPMENT OR AN ONSITE GENERATOR. [2022 CBC 1008.3.4] 4. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS NOT LESS THAN AN AVERAGE OF 1 FC, AND A MIN AT ANY POINT OF 0.1 FC MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FC AVERAGE AND A MIN AT ANY POINT OF 0.06 FC AT THE END OF THEEMERGENCY LIGHTING TIME DURATION. A MAX-TO-MIN ILLUMINATIONUNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED. [2022 CBC 1008.3.5] 5. EXITS AND EXIT ACCESS DOORS SHALL BE MARKED BY AN APPROVED EXITSIGN READILY VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL. EXIT SIGNPLACEMENT SHALL BE SUCH THAT ANY POINT IN AN EXIT ACCESS CORRIDOROR EXIT PASSAGEWAY IS WITHIN 100 FT OR THE LISTED VIEWING DISTANCEOF THE SIGN, WHICHEVER IS LESS, FROM THE NEAREST VISIBLE EXIT SIGN.[2022 CBC 1013.1] 6. TACTILE EXIT SIGNS SHALL BE PROVIDED WITH APPROPRIATE WORDS AT EXIT DOORS LEADING TO ENCLOSED EXIT STAIRWAYS AND EXIT DOORS LEADING TO OUTSIDE. [2022 CBC 1013.4] 7. EMERGENCY LIGHTING UNITS SHALL BE EQUIPPED WITH FACTORY INSTALLED INTEGRAL TEST SWITCHES. NOTES:1. FIXTURE SHALL HAVE MIN. OF 10 YEARS MANUFACTURER WARRANTY ON ALL COMPONENTS.2. FIXTURES SHALL HAVE APPROPRIATE U.L. LABEL (i.c., DAMP OR WET) AS REQUIRED BY CODES AND ORDINANCES.3. FIXTURES SHALL INCLUDE ALL ACCESSORIES FOR INSTALLATION ACCORDING TO MANUFACTURER'S SHOPDRAWINGS AND AS REQUIRED BY CODES AND LOCAL ORDINANCES.4. PRIOR TO ORDERING ANY LIGHTING EQUIPMENT, THE CONTRACT OR SHALL COORDINATE ALL FIXTURE LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS AND CEILING CAVITY DEPTHS. 5. ALL LAMPS SHALL BE PROVIDED AND INSTALLED ACCORDING TO THE ATTACHED FIXTURE SCHEDULE AND SPECIFICATIONS. ENSURE COMPATIBILITY BETWEEN FIXTURE, LAMP(S) AND BALLAST(S). 6. CONTRACTOR SHALL VERIFY FIXTURE VOLTAGES AND CEILING TRIM COMPATIBILITY PRIOR TO ORDERING FIXTURE. 7. PROVIDE APPROVED FIRE-RATED ENCLOSURES FOR ALL LIGHTING FIXTURES LOCATED IN FIRE-RATED CEILINGS. 8. LIGHTING FIXTURE CATALOG NUMBERS ARE SERIES TYPE ONLY. PROVIDE ALL NECESSARY HARDWARE ASREQUIRED BY THE SPECIFICATIONS, DRAWINGS, AND PROJECT CONDITIONS FOR A COMPLETE INSTALLATION.9. ALL FIXTURES SHALL BE ORDERED WITH APPROPRIATE BALLAST(S) THAT HAVE U.L. AND CBM LABELS. PROVIDEMULTIPLE BALLASTS FOR DUAL-LEVEL SWITCHING AND WIRING AS INDICATED ON THE PLANS.10. ENSURE COMPATIBILITY OF ALL LIGHTING SYSTEM COMPONENTS, ESPECIALLY DIMMED SYSTEMS. FIXTURES,LAMPS, BALLAST(S), AND DIMMING SYSTEMS/INDIVIDUAL CONTROLS MUST BE FACTORY CERTIFIED COMPATIBLEFOR FULL RANGE OF DIMMING COMPATIBILITY.11. LIGHTING FIXTURE MANUFACTURER & MODEL IS FOR REFERENCE ONLY. FIXTURE SHALL BE SELECTED BY ARCHITECT. POWER AND QUALITY SHALL BE SPECIFICATION GRADE.SINGLE LINE DIAGRAM NOTES 1. CONTRACTOR/ELECTRICIAN TO FIELD VERIFY ACTUAL SITE CONDITION/EXACT SERVICE ENTRANCE AND SHALL NOTIFY EOR(S) ANY DISCREPANCYWITH THE PLAN PRIOR TO BIDDING. 2. CONTRACTOR TO VERIFY ALL EQUIPMENT DIMENSIONS AND CLEARANCESWITH FIELD CONDITION PRIOR TO ORDERING EQUIPMENT. 3. ALL EQUIPMENT TO BE LISTED BY A RECOGNIZED TESTING AGENCY. TERMINALS TO BE RATED FOR ALUMINUM AND COPPER WIRE. 4. CONTRACTOR TO OBTAIN A FAULT CURRENT LETTER FROM UTILITY COMPANY PRIOR TO PURCHASE OF ANY EQUIPMENT (IF ANY) FOR AIC VERIFICATION. EQUIPMENT CUTSHEETS AND FAULT CURRENT LETTER TO BEPROVIDED UPON INSPECTION. 5. IF APPLICABLE, ALL NEW CIRCUIT BREAKERS INSTALLED ON EXISTINGPANEL/SWITCHBOARD SHALL MATCH THE HIGHEST EXISTING AIC RATEDBREAKER WITHIN THAT PANEL/BOARD. INSPECTOR TO VERIFY HIGHEST AICRATING AT THE SITE. 6. MAIN SERVICE DISCONNECT AMPERAGE MUST BE PERMANENTLY MARKED 7. ALL SYSTEM TO BE FULLY RATED SYSTEM. IF SYSTEM IS SERIES RATED, ALLCOMPONENTS MUST BE FROM THE SAME MANUFACTURER. LISTED BREAKERCOMBINATIONS SHALL BE AVAILABLE TO THE AUTHORITY HAVING JURISDICTION UPON REQUEST. 8. IF APPLICABLE, ALL EQUIPMENT LABELED/IDENTIFIED AS EXISTING, ARE SUBJECT TO FIELD VERIFICATION. 9. ARC-FLASH HAZARD WARNING FIELD MARKING TO BE PROVIDED ON ELECTRICAL EQUIPMENT, SUCH AS SWITCHBOARDS, PANEL BOARDS, METERSOCKET ENCLOSURES AND MCC THAT ARE IN OTHER THAN DWELLING UNITS.[2022 CEC 110.21(B)] 10. SERVICE EQUIPMENT SHALL BE FIELD MARKED WITH THE MAXIMUMAVAILABLE FAULT CURRENT. [2022 CEC 110.24]SINGLE LINE DIAGRAM FEEDER CHART (E)/(N)FEEDER SIZE 400S (E)4#600- 4"C (BY UTILITY) 200 (N)4#3/0, #6GND- 2"C 100 (E)4#1, #8GND- 2"C NOTE: (E) FEEDERS TO BE FIELD VERIFIED AND REMAIN AS-IS U.O.N. # G N (E) MAIN SWITCHBOARD "MS"400A, 120/208V, 3Ø, 4W22K AIC RATING, NEMA 3R ENCLOSURE (E) #1/0 CU.GND M 200 400S M 100 M 100 *EXISTING TIME CLOCK MAY BE UTILIZED. CONTRACTOR TO VERIFY CONDITION IN FIELD. S(Override) = LIGHTING OVERRIDE SWITCH, AT FRONT DOOR. TC = LIGHTS TIME CLOCK WITH OVERRIDE ON/OFF CONTROL SPECIFIC NOTES:DESIGNATED NON EMERGENCYLIGHTING CIRCUITS SHALL BECONTROLLED BY 24 HR TIME CLOCKTHROUGH MULTI-POLE CONTACTOR.TIME CLOCK SHALL INCORPORATE ANAUTOMATIC HOLIDAY "SHUT-OFF"FEATURE. INTERMATIC ET2800 SERIES (INDOOR)/ET8000 SERIES (OUTDOOR) OR EQUIV. (E) UTILITY COMPANYSECONDARY FEEDER (N)200A3P BLDGSTRUCTSTEEL UFERGNDGNDROD COLDWTRPIPE (N) PANEL"A" (E)100A3P (N) PANEL"B"(E) PANEL"E" (E)100A3P (E)400A3P CONTRACTOR TO FIELD IDENTIFY DEMOLISHED SPARE CIRCUITS TOINSTALL NEW LOAD. CIRCUIT LOCATIONS SHOWN ON THIS DRAWING ISFOR INFORMATIONAL PURPOSE ONLY. EXACT CIRCUIT LOCATIONS ARE SUBJECT TO FIELD VERIFICATION. REMAINING EXISTING CIRCUITS TO BE RECONNECTED OR REMAIN AS-IS. RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 1/16/2024 5:40:02 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: N.T.S. E001 SINGLE LINE DIAGRAM/ SCHEDULES J.L.K.T 2 DAYLIGHT CONTROL EXCEPTION NOTES: DAYLIGHT CONTROL: COMBINED TOTAL GENERAL LIGHTING POWER IN PRIMARY/SECONDARY SIDELIT DAYLIT ZONE IS LESS THAN 120 WATTS. NODAYLIGHT CONTROL REQUIRED. [2022 CENC130.1(D)EXCEPTION(3)] LIGHTING PLAN E E E E E E E E E E E E EE E E E E E E E EM 1 EM 1 EM 1 EM 1 EM 1 EM 1 X 1 EM 1 EMX 1EMX1EMX1 X 1 X 1 X 1 EM 1 WP SIGNAGE J 3 A-34 EE EE EE EE EE EE EE EE EE EE D A-32 A-32 D OS A-32 A-32 D A-30 OS OS D/OS A-30 D/OS A-30 D/OS A-30 D/OS A-30 OS A-30 GENERAL NOTES: 1. ELECTRICAL EQUIPMENT SHALL BE LISTED BY U.L. ORCITY RECOGNIZED ELECTRICAL TESTINGLABORATORY OR APPROVED BY THE CITYDEPARTMENT. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE [2022 CEC]. 3. WIRE SIZE SHALL NOT BE LESS THAN CORRESPONDING CIRCUIT BREAKER RATING AS REQUIRED. [2022 CEC TABLE 310.16] 4. CONDUIT SHALL BE SIZED IN ACCORDANCE WITH THE[2022 CEC ANNEX C]. 5. CONTRACTOR/ELECTRICIAN TO FIELD VERIFY ACTUALSITE CONDITION /EXACT SERVICE ENTRANCE ANDSHALL NOTIFY EOR(S) ANY DISCREPANCY WITH THEPLAN PRIOR TO BIDDING. 6. ALL ITEMS LABELED/IDENTIFIED AS EXISTING (IF ANY)ARE SUBJECT TO FIELD VERIFICATION. VERIFYEXISTING CONDITION AND RE-USE. IF NOT EXISTING,PROVIDE PER PLAN. 7. OBTAIN APPROVAL ON LOCATION OF SWITCH/DIMMER/SENSOR WITH ARCHITECT/OWNER AT SITE PRIOR TO ROUGH-IN. 8. SIGNAGE WILL REQUIRE SEPARATE PERMIT AND SUBMITTAL. 9. REFER TO EMERGENCY EXIT ILLUMINATION NOTESFOR EMERGENCY LIGHTING REQUIREMENTS. 10. IN OFFICES 250 SQUARE FEET OR SMALLER,MULTIPURPOSE ROOMS OF LESS THAN 1,000 SQUAREFEET, CLASSROOMS OF ANY SIZE, CONFERENCEROOMS OF ANY SIZE, AND RESTROOMS OF ANY SIZE,LIGHTING SHALL BE CONTROLLED WITH OCCUPANTSENSING CONTROLS TO AUTOMATICALLY SHUT OFF ALL OF THE LIGHTING IN 20 MINUTES OR LESS AFTER THE CONTROL ZONE IS UNOCCUPIED. [2022 CENC 130.1(C)(5)] A. IN AREAS W/ MULTI-LEVEL LIGHTING CONTROLS,THE OCCUPANT SENSING CONTROLS SHALLFUNCTION AS A PARTIAL-ON OCCUPANT SENSING CONTROLS CAPABLE OF AUTOMATICALLY ACTIVATING BETWEEN 50 AND 70 PERCENT OF CONTROLLED LIGHTING POWER B. IN AREAS W/O MULTILEVEL LIGHTING CONTROLS, THE OCCUPANT SENSING CONTROLS SHALLFUNCTION AS A VACANCY SENSING CONTROLS,WHERE ALL LIGHTING RESPONDS TO A MANUAL ONINPUT ONLY. 11. IN AISLE WAYS AND OPEN AREAS IN WAREHOUSES,LIGHTING SHALL BE CONTROLLED WITH OCCUPANTSENSING CONTROLS THAT AUTOMATICALLY REDUCELIGHTING POWER BY AT LEAST 50 PERCENT WHENTHE AREAS ARE UNOCCUPIED. THE OCCUPANT SENSING CONTROLS SHALL INDEPENDENTLY CONTROL LIGHTING IN EACH AISLE WAY, AND SHALL NOT CONTROL LIGHTING BEYOND THE AISLE WAY BEING CONTROLLED BY THE SENSOR. [2022 CENC 130.1(C)(6)(A)] 12. IN CORRIDORS AND STAIRWELLS, LIGHTING SHALL BECONTROLLED BY OCCUPANT SENSING CONTROLSTHAT SEPARATELY REDUCE THE LIGHTING POWER INEACH SPACE BY AT LEAST 50 PERCENT WHEN THESPACE IS UNOCCUPIED. THE OCCUPANT SENSINGCONTROLS SHALL BE CAPABLE OF AUTOMATICALLYTURNING THE LIGHTING FULLY ON ONLY IN THESEPARATELY CONTROLLED SPACE, AND SHALL BE AUTOMATICALLY ACTIVATED FROM ALL DESIGNED PATHS OF EGRESS. [2022 CENC 130.1(C)(6)(C)] 13. TIME CLOCK SHALL INCORPORATE A MANUAL OVERRIDE LIGHTING CONTROL THAT COMPLIES WITH SECTION 130.1(A); AND ALLOWS THE LIGHTING TOREMAIN ON FOR NO MORE THAN 2 HOURS WHEN ANOVERRIDE IS INITIATED; AND SHALL INCORPORATE ANAUTOMATIC HOLIDAY "SHUT-OFF" FEATURE THATTURNS OFF ALL LOADS FOR AT LEAST 24 HOURS, ANDTHEN RESUMES THE NORMALLY SCHEDULEDOPERATION. [2022 CENC 130.1(C)(3)&(4)]. 2. EMERGENCY/NL AND EXIT FIXTURES TO BE CONNECTED TO NEARBY ROOM LIGHTING CIRCUIT AHEAD OF LOCAL SWITCH. IF EXISTING, VERIFY CONDITION AND RE-USE. [CEC 700.12(I)(2)(3)(A)] 3. CONTRACTOR TO VERIFY FINAL LOCATION OF SWITCH/DIMMER/CONTROL PACK WITH THE ARCHITECT/OWNER PRIOR TO ROUGH-IN. 4. WIRE THRU CONTACTOR & TIME CLOCK FOR SIGNAGE LIGHTING CONTROL. 5. ALL EXISTING LIGHTING/CONTROL FIXTURES IN THIS AREA TO REMAIN U.O.N.NOT IN SCOPE. #KEYED LIGHTING PLAN NOTES: 4 4 4 4 S S A-30 A-30 X1 X 1 X 1 EM 1EM1 EM 1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2L2 Dim a Dim a1 Dim a2 UTILITY ROOM PRODUCT STORAGE LOUNGE ROOM RECEPTION MANUFACTURE STOCK PRODUCT BREAK ROOM DELIVER OFFICE COMMON HALLWAY RECEPTION A.R.R.1 A.R.R.2 OFFICEMANUFACTURE AREA RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 1/16/2024 5:40:03 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: E100 1/4" = 1'-0" LIGHTING PLAN J.L.K.T 2 4 POWER PLAN -28A -9A -11A -1A -3A -5A -7A -2A-4A-6A-8A -33A -31A -35A -37A -39A -41A PANEL"A" -30E 2 2 2 2 TC A-4211 GENERAL NOTES: 1. ELECTRICAL EQUIPMENT SHALL BE LISTED BY U.L. OR CITY RECOGNIZEDELECTRICAL TESTING LABORATORY OR APPROVED BY THE CITYDEPARTMENT. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE [2022 CEC]. 3. WIRE SIZE SHALL NOT BE LESS THAN CORRESPONDING CIRCUIT BREAKERRATING AS REQUIRED. [2022 CEC TABLE 310.16] 4. CONDUIT SHALL BE SIZED IN ACCORDANCE WITH THE [2022 CEC ANNEX C]. 5. CONTRACTOR/ELECTRICIAN TO FIELD VERIFY ACTUAL SITE CONDITION/EXACT SERVICE ENTRANCE AND SHALL NOTIFY EOR(S) ANY DISCREPANCY WITH THE PLAN PRIOR TO BIDDING. 6. ALL ITEMS LABELED/IDENTIFIED AS EXISTING (IF ANY) ARE SUBJECT TO FIELD VERIFICATION. VERIFY EXISTING CONDITION AND RE-USE. IF NOT EXISTING, PROVIDE PER PLAN. 7. COORDINATE LOCATIONS/HEIGHTS OF RECEPTACLES FOR ELECTRICAL DEVICES WITH ARCHITECT AND EQUIPMENT VENDER PRIOR TO ROUGH-IN. 8. ALL NEW ELECTRICAL EQUIPMENT (IF ANY) DIMENSIONS TO BE VERIFIEDWITH EQUIPMENT MANUFACTURER/VENDER PRIOR TO PURCHASE. 9. GFCI PROTECTION: ALL 125V THROUGH 250V RECEPTACLES SUPPLIED BY1-PHASE BRANCH CIRCUITS, 50 AMPERES OR LESS, AND ALL RECEPTACLESSUPPLIED BY 3-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TOGROUND, 100 AMPERES OR LESS, INSTALLED IN THE FOLLOWING LOCATIONSSHALL HAVE GFCI PROTECTION FOR PERSONNEL. [2022 CEC 210.8(B)]A. BATHROOMSB. KITCHENS OR AREAS WITH A SINK AND PREM. PROVISION FOR COOKING C. ROOFTOPS/OUTDOORS D. SINKS - WITHIN 6FT FROM THE TOP INSIDE EDGE OF THE SINK E. GARAGES, UNFINISHED AREAS OF BASEMENTS OR SIMILAR AREAS 10. FOR ALL PERMANENTLY CONNECTED APPLIANCES RATED OVER 300VA, THECIRCUIT BREAKER CAPABLE OF BEING LOCKED IN THE OPEN POSITIONSHALL BE PROVIDED UNLESS LOCATION OF THE BREAKER IS WITHIN THESIGHT OR SEPARATE DISCONNECTING MEANS IS PROVIDED. [2022 CEC110.25, 422.31(B)] KEYED POWER PLAN NOTES:# -26E -28E -29E -10E -12E -14E PANEL"E"1 4 . S u g a r B o i l e r 5 . I n f u s i o n M a c h i n e B-18/20 A-18/20/22 22 B-24/26/28 A-15/17 2 A-19/21 A-23/25 A-27/29 B-21/23 B-25/27 B-2/4 B-6/8 A-10/12 A-14/16 2 2 B-15/17 A-26 A-24 WHA-36/38 2 1 CF 1 CF 1 CF 1CF 4RTU RTU3 -17E WR/WP (ON ROOF) 3 WR/WP (ON ROOF) 3 4 4 4 44 HVAC SYSTEM CONNECTION SCHEDULE EQUIPMENT CIRCUITDESIGNATION VOLT/PHASE FEEDER DISCONNECT RTU-3 E-5/7/9 208V/3PH 3#6, #10GND- 1"C 45AF/60AS/3P RTU-4 E-11/13/15 208V/3PH 3#6, #10GND- 1"C 45AF/60AS/3P MECHANICAL EQUIPMENT NOTES: 1. PROVIDE OVERCURRENT PROTECTION AND BRANCH CIRCUITS PER UL LISTED REQUIREMENTS FOR EQUIPMENT SERVED. REFER TO MANUFACTURER DATAAND EQUIPMENT CUT-SHEETS FOR ROUGH-IN LOCATIONS OF ELECTRICALCONNECTIONS AND INTERCONNECTIONS FOR ALL EQUIPMENT. COORDINATEEXACT NAMEPLATE DATA OF EQUIPMENT BEING INSTALLED WITH MECHANICALCONTRACTOR. 2. SWITCHES USED AS DISCONNECTING MEANS SHALL BE LOCATED WITHIN SIGHTOF EQUIPMENT. PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR.NON-FUSED DISCONNECT IS ACCEPTABLE INSTEAD OF SPECIFIED FUSE TYPE. 3. ADJUST SIZE OF CONDUCTORS AS NEEDED COMPENSATE FOR VOLTAGE DROP.VOLTAGE DROP SHALL NOT EXCEED 3% FOR BRANCH CIRCUITS. 4. REFER TO MECHANICAL PLAN FOR MORE INFO. 5. IF EXISTING UNITS ARE RE-USED, EXISTING DISCONNECT/FUSE/BREAKER TO BE RE-USED OR REPLACED WITH SAME RATING. VERIFY EXISTING CONDITION IN FIELD. UTILITY ROOM PRODUCT STORAGE LOUNGE ROOM RECEPTION MANUFACTURE STOCK PRODUCT BREAK ROOM DELIVER OFFICE COMMON HALLWAY RECEPTION A.R.R.1 A.R.R.2 OFFICE MANUFACTURE AREA 13 . P U M P 1 14 . P U M P 2 15 . E L E C T R O N I C S 13 . P U M P 1 14 . P U M P 2 15 . E L E C T R O N I C S 16 . H E A T E R 17. CONTAINER 18. CONTAINER 19. HEATER 13. PUMP 1 15. ELECTRONICS 20. OVEN 1 20. OVEN 1 21. OVEN 2 9. FILLINGMACHINE 10. CAPINGMACHINE 10. CAPING MACHINE 12. AUTOMATIC BOX PACKING MACHINE (FUTURE) 14. PUMP 2 #3 #10 #10 #10 1. VERIFY/COORDINATE EXACT LOCATION FOR ELECTRICAL EQUIPMENTS AND PROVIDE/MAINTAIN MINIMUM CLEARANCE. [2022 CEC 110.26] 2. VERIFY EXACT ELECTRICAL INSTALLATION REQUIREMENTS WITH MANUFACTURER AND PROVIDE PER RECOMMENDATION. 3. PROVIDE GFCI/WATERPROOF/WEATHER RESISTANT RECEPTACLE WITHIN 25FT OF HEATING, AC, AND REFRIGERATION EQUIPMENT. 4. REFER TO MECHANICAL PLAN AND HVAC SYSTEM CONNECTION SCHEDULEFOR EXACT LOCATIONS, SPECS AND INSTALLATION REQUIREMENTS. 5. PROVIDE 3 WIRE STUB FOR FUTURE EQUIPMENT CONNECTION FROM PANEL"B" LOCATION. 9. FILLINGMACHINE 9. FILLINGMACHINE 9. FILLING MACHINE 9. FILLING MACHINE 9. FILLINGMACHINE 2.Stirring Container 3.VacuumPump 6. D e m o l d i n g Ma c h i n e 8.AirCompressor 7. PolishingPot #10 #8 21. OVEN 2 21. OVEN 2 21. OVEN 2 #10 #10 #10 #10 ( ON CEILING ) ( ON CEILING )( ON CEILING ) ( ON CEILING ) E-19 E-19 ( ON ROOF ) ( ON ROOF ) J B-1 B-3B-16B-14B-10B-12 B-7 B-9 B-19 -16E -18E A-40 S -20E-22E -24E +8" CT +8" CT PANEL"B" -13A B-30/32 B-34/36 11. PLASTIC BAGPACKING MACHINE(FUTURE) 55 COMPRESSOR(ON ROOF) FJ B-11/13 2 40AF/ 60AS/ 2P #8 RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 1/16/2024 5:40:04 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: E200 1/4" = 1'-0" POWER PLAN J.L.K.T TITLE24 - INDOOR RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 1/16/2024 5:40:06 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: N.T.S. TE00 TITLE24 - INDOOR J.L.K.T 11818 CLARK ST, 9890 RESEARCH DR. SUITE 100 IRVINE, CA 92618 11818 CLARK ST,11818 CLARK ST,11818 CLARK ST, 11818 CLARK ST,11818 CLARK ST, 11818 CLARK ST, 949-533-4117 9890 RESEARCH DR. SUITE 100 IRVINE, CA 92618 949-533-4117 E24049 1/16/2024 1/16/2024 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 SHEET INDEX ·EXISTING COMMERCIAL TENANT IMPROVEMENT. ·PROVIDE NEW HVAC UNITS AND REUSE THE EXISTING HVAC UNITS. ·PROVIDE DUCTWORKS AND AIR DEVICES THROUGHOUT THE SPACE. M000 M001 M002 M100 M101 TM00 MECHANICAL NOTES MECHANICAL SCHEDULES MECHANICAL DETAILS MECHANICAL PLAN - ROOF PLAN MECHANICAL TITLE 24 - 1 TM01 MECHANICAL PLAN MECHANICAL TITLE 24 - 2 SYMBOLS AND ABBREVIATIONS T RETURN AIR PLENUM CROSS-SECTION SUPPLY AIR PLENUM CROSS-SECTION EXHAUST AIR CUBIC FEET PER MINUTE EXTERNAL STATIC PRESSURE SIDE WALL RETURN GRILLE THERMOSTAT SUPPLY DIFFUSER SIDE WALL SUPPLY REGISTER RETURN AIR GRILLE EXHAUST AIR GRILLE / CEILING EXHAUST FAN ESP CFM EA EXISTING FIRE DAMPER HORSEPOWER HERTZ RETURN AIR TYPICAL SUPPLY AIR MANUAL VOLUME DAMPER OUTSIDE SUPPLY AIR SMOKE DETECTOR STATIC PRESSURE FULL LOAD AMPERES VOLT UNDERCUT DOOR UP THRU ROOF MVD V TYP U.T.R. SD SA SP RA OSA FLA HP HZ EXIST FD SD NOTE: REFER TO PLAN SHEETS FOR ANY ADDITIONAL LEGEND,SYMBOLS ANDRELATEDABBREVIATIONS. D U S SENSOR EF (E) ROOF MOUNTED EXHAUST FAN NEWNEW(N) U/C CO2 SENSORCO2 1RTU MECHANICAL EQUIPMENT TAG POC NEW DUCT EXISTING DUCT CONDENSATE DRAINCD REFRIGERANT LINEREF OSA INTAKE OSA DUCTOSA FD CO SENSORCO FIRE SMOKE DAMPERFSDFSD ABBR.SYMBOL DESCRIPTION CONDENSATE DRAIN CLEANOUT HVAC SPECIFICATIONS PIPE INSULATION THICKNESS 4. 5. 6. 1. 7. 2. 3. CONCEALED SPACES, CIRCULATION AIR INSULATION OF DUCTS FLUIDTEMP.RANGE(°F) CONDUCTIVITYRANGE(BTU-"/HR PERSQFT/°F) INSULATIONMEANRATINGTEMP. (°F) NOMINAL PIPE DIAMETER (") INSULATION THICKNESS REQUIRED (") <1 1 TO<1.5 1.5 TO<4 4 TO <8 8 ANDLARGER 251-350 350< 201-250 141-200 105-140 40-60 <40 SPACE COOLING SYSTEMS (CHILLED WATER, REFRIGERANT AND BRINE) SPACE HEATING, HOT WATER SYSTEMS AND SERVICE WATER HEATING SYSTEMS 0.32-0.34 0.29-0.31 0.27-0.30 0.25-0.29 0.22-0.28 0.21-0.27 0.20-0.26 250 200 150 125 100 75 50 4.5 3.0 2.5 1.5 1.0 1.0 5.0 4.0 2.5 1.5 1.5 1.5 5.0 4.5 2.5 2.0 1.5 1.5 5.0 4.5 3.0 2.0 1.5 1.5 5.0 4.5 3.0 2.0 1.5 1.5 A MAINTENANCE LABEL SHALL BE AFFIXED TO MECHANICAL EQUIPMENT AND A MAINTENANCE MANUAL SHALL BE PROVIDED TO THE OWNER PER STANDARDS. EXCEPT AS ALLOWED, THESE CONTROLS SHALL BE ADJUSTABLE TOPROVIDE A DEAD BAND OF 5 DEGREES F BETWEEN FULL HEATING AND FULL COOLING. CONTROLS SHALL HAVE THE CAPABILITY OF TERMINATING ALL HEATING AT A TEMPERATURE NO MORE THAN 70 DEGREES F AND OF TERMINATING ALL COOLING AT A TEMPERATURE NOT LESS THAN 78 DEGREES F. EACH HVAC SYSTEM SHALL BE PROVIDED WITH AT LEAST ONE AUTOMATIC TEMPERATURE CONTROL DEVICE FOR THE REGULATION OF TEMPERATURE THESE AUTOMATIC TEMPERATURE CONTROL DEVICES SHALL BE CAPABLE OF BEING SET TO MAINTAIN SPACE TEMPERATURE SET POINTS FROM 55 DEGREES F TO 85 DEGREES F, SHALL BE CAPABLE OF OPERATING THESYSTEM HEATING AND/OR COOLING IN SEQUENCE. EXCEPTIONS:(1) FACTORY-INSTALLED PIPING WITHIN SPACE CONDITIONING EQUIPMENT;(2) PIPING THAT CONVEYS FLUIDS THAT HAVE A DESIGN OPERATINGTEMPERATURE RANGE BETWEEN 60 DEGREES AND 105 DEGREESFAHRENHEIT;(3) WHERE THE HEAT GAIN OR HEAT LOSS TO OR FROM PIPING WITHOUTINSULATION WILL NOT INCREASE BUILDING SOURCE ENERGY USE;(4) PIPING THAT PENETRATES FRAMING MEMBERS SHALL NOT BE REQUIRED TO HAVE PIPE INSULATION FOR THE DISTANCE OF THE FRAMING PENETRATION. METAL PIPING THAT PENETRATES METAL FRAMING SHALL USE GROMMETS, PLUGS, WRAPPING OR OTHER INSULATING MATERIAL TO ASSURE THAT NO CONTACT IS MADE WITHTHE METAL FRAMING. INSPECTION TO BE MADE AND DUCTWORK APPROVED BEFORE COVERING WITH INSULATION. TRANSVERSE SUPPLY DUCTS, TAPED OR SEALED WITH MASTIC EXCEPT FORDUCTS EXPOSED TO CONDITIONED SPACE, WHERE DUCT STATIC PRESSUREEXCEEDS 3/4" WATER, LONGTITUDINAL JOINTS, TAPED OR SEALED WITHMASTIC. SEALING INSPECTION PIPE INSULATION SPACE-CONDITIONING AND SERVICE WATER-HEATING SYSTEM SHALL BEINSULATED IN ACCORDANCE WITH THE FOLLOWING TABLE: INSULATED WIRES, PLASTIC TUBING OR PIPING, PIPE INSULATION,CONDENSATE PAN INSULATION, WOOD, PVC, ABS AND OTHER PLASTICS) TO BE IN CONCEALED SPACES USED TO CONVEY CIRCULATING AIR SUPPLY. WHEN COMBUSTIBLE MATERIAL IS TO BE LOCATED IN THE ABOVE SPACES, IT SHALL BE APPROVED FOR SUCH INSULATION. TEMPERATURE CONTROLS PORTIONS OF SUPPLY-AIR AND RETURN-AIR DUCTS CONVEYING HEATED ORCOOLED AIR LOCATED IN ONE OR MORE OF THE FOLLOWING SPACES SHALLBE INSULATED TO A MINIMUM INSTALLED LEVEL OF R-8: 1. OUTDOORS; OR 2. IN A SPACE BETWEEN THE ROOF AND AN INSULATED CEILING; OR 3. IN A SPACE DIRECTLY UNDER A ROOF WITH FIXED VENTS OR OPENINGS TO THE OUTSIDE OR UNCONDITIONED SPACES; OR 4. IN AN UNCONDITIONED CRAWL SPACE; OR 5. IN OTHER UNCONDITIONED SPACES. PORTIONS OF SUPPLY-AIR DUCTS THAT ARE NOT IN ONE OF THESE SPACES,INCLUDING DUCTS BURIED IN CONCRETE SLAB, SHALL BE INSULATED TO AMINIMUM INSTALLED LEVEL OF R-4.2 OR BE ENCLOSED IN DIRECTLYCONDITIONED SPACE. NONRES 0.5 RES 0.75 1.01.0 1.0 26. CONDENSATE WASTE SHALL CONNECT INDIRECTLY TO THE DRAINAGESYSTEM THROUGH AN AIR GAP OR AIR BREAK TO PROPERLY TRAPPEDAND VENTED RECEPTORS, DRY WELLS, OR THE TAILPIECE OF A PLUMBINGFIXTURE. 27. WHERE CONDENSATE WASTE FROM AIR CONDITIONING COILS DISCHARGES BY DIRECT CONNECTION TO A LAVATORY TAILPIECE OR TO AN APPROVED ACCESSIBLE INLET ON A BATHTUB OVERFLOW, THE CONNECTION SHALL BE LOCATED IN AN AREA CONTROLLED BY THE SAMEPERSON CONTROLLING THE AIR-CONDITIONED SPACE. 28. THE REFRIGERATION EQUIPMENT REFRIGERANT SERVICE PORTSLOCATED OUTDOORS SHALL BE FITTED WITH LOCKING TYPE TAMPERRESISTANT CAPS OR SHALL BE PROTECTED FROM UNAUTHORIZEDACCESS BY A MEANS ACCEPTABLE TO THE ENFORCING AGENCY. 29. THE HEATING AND COOLING DUCT SYSTEM IS SIZED IN ACCORDANCE WITH ASHRAE. 30. G.C. TO VERIFY SUFFICIENCY OF DUCT SPACE BEFORE PURCHASING ANY MECHANICAL EQUIPMENT. 31. DUCTWORK SHALL BE INSULATED OR LINED AS NOTED ON DRAWINGS. ALLDUCTWORK EXPOSED ON ROOF SHALL BE INTERNALLY LINED UNLESSOTHERWISE INDICATED OR SPECIFIED. ALL DUCT SIZES ARE SHEET METALSIZES. ALL DUCT JOINTS SHALL BE SEALED PER SPECIFICATIONS. 32. CONNECT MAIN DUCT TO AIR CONDITIONING UNIT WITH WEATHERPROOFFLEXIBLE CONNECTION. SUN SHIELD OVER ENTIRE FLEXIBLECONNECTIONS REQUIRED IF FLEXIBLE CONNECTION IS EXPOSED TO WEATHER. 33. ALL LINED DUCT DIMENSIONS ARE NET CLEAR DIMENSION AFTER LINING HAS BEEN INSTALLED. 34. ALL DUCTWORK SIZE SHOWN ON PLAN ARE INTERIOR DIAMETER.CONTRACTOR SHALL ADD INSULATION THICKNESS INTO CONSIDERATIONBEFORE INSTALLATION. 35. DUCTS SHALL BE SUPPORTED WITH 1" WIDE 16-GAUGE HANGER STRAPSAND SHALL BE SPACED AT NO MORE THAN 7'-0" ON CENTERS AND SHALLBE SECURED TO STRUCTURAL MEMBER. EXPOSED DUCTWORK ON ROOFSHALL BE SUPPORTED BY GALVANIZED STEEL ANGLE & SHALL BE PER LOCAL CODE. 36. ROUND AND RECTANGULAR DUCTWORK ARE INTERCHANGEABLE IF CROSS SECTION AREAS ARE EQUIVALENT. CONTRACTOR IS TO VERIFY THEEXACT CEILING SPACE AND INTERCHANGE THE DUCT SIZE TO FIT THECEILING SPACE WITHOUT ADDITIONAL FEE CHARGE. 37. ALL FACTORY-FABRICATED DUCT SYSTEMS SHALL COMPLY WITH UL 181FOR DUCTS AND CLOSURE SYSTEMS, INCLUDING COLLARS,CONNECTIONS, AND SPLICES, AND BE LABELED AS COMPLYING WITH UL181. 38. INSTALL VOLUME CONTROL DAMPERS AT EACH SUPPLY DIFFUSER TO AFFORD COMPLETE CONTROL OF THE AIR FLOW IN THE VARIOUS DUCT SYSTEMS. INSTALL SPLITTER DAMPER AT DUCT TAKEOFFS AND DAMPER AS REQUIRED. 39. AUTOMATIC FIRE DAMPER REQUIREMENTS ARE AS FOLLOWS:a. PROVIDE AUTOMATIC FIRE DAMPERS AT ALL PENETRATIONSOF FIRE-RATED CEILINGS AND WALLS THROUGHOUT.CONTRACTOR SHALL COORDINATE WITH FIRE-RATED CEILINGAREAS AND WALLS AS INDICATED ON ARCHITECTURALDRAWINGS. THIS NOTE SHALL TAKE PRECEDENCE OVER ANY OMISSIONS ON THE DRAWINGS. SEE SPECIFICATIONS. b. LOCATION OF FIRE-RATED CEILINGS AND WALLS ARE AS INDICATED ON THE ARCHITECTURAL DRAWINGS. 40. COORDINATE THE LOCATION OF ALL CEILING DIFFUSERS, REGISTERS ANDGRILLES WITH THE ARCHITECTURAL REFLECTED CEILING PLAN,ELECTRICAL LIGHTING LAYOUT AND ARCHITECTURAL ROOM ELEVATIONS. 41. ALL CEILING DIFFUSERS ARE 4-WAY UNLESS OTHERWISE NOTED. 42. PROVIDE BACK-DRAFT DAMPER FOR ALL EXHAUST AIR DUCT UNLESSOTHERWISE NOTED PER CODE. 43. EXHAUST TERMINATION SHALL BE MINIMUM 10'-0" AWAY OR 3'-0" ABOVE FROM ANY FRESH AIR INTAKE, OPERABLE WINDOWS, DOORS AND 10'-0" MINIMUM ABOVE GRADE. 44. PROVIDE ALL FRESH AIR INTAKES AND EXHAUST OUTLETS WITH HOOD, 1/2"GALVANIZED MESH SCREENS AND OUTSIDE AIR BACK-DRAFT DAMPERS. 45. ALL HVAC UNITS OR SYSTEMS SERVING A COMMON AIR SPACE MUST BEINTERCONNECTED TO SHUT DOWN IMMEDIATELY UPON ALARM CONDITIONFROM DUCT DETECTORS (OR FIRE ALARM SYSTEM WHEN USING AREASMOKE DETECTORS IN LIEU OF DUCT DETECTORS) WITHOUTINTERFERENCE FROM EMS OR ANY OTHER SYSTEMS. ALL CONTROL RELAYS USED FOR SHUT DOWN MUST BE APPROVED BY STATE OR LOCAL JURISDICTION FOR RELEASING SERVICE. 46. PURCHASING PARTY SHALL ENSURE THE MOTOR SPECS PRIOR TO ORDERING EXHAUST SYSTEM TO ENSURE THE PANEL IS BUILTCORRECTLY. 47. REDWOOD SLEEPER OR PLATFORM FOR ROOF MOUNTED UNIT, DUCTPENETRATION, CUTTING AND PATCHING BY GENERAL CONTRACTOR,UNLESS OTHERWISE NOTED ON PLAN. 48. 42" MINIMUM GUARDS TO BE PROVIDED WHEN ROOF MOUNTED OR ROOFACCESS EQUIPMENT THAT REQUIRE SERVICE ARE LOCATED WITHIN 10' OF A ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN 30" ABOVE THE ROOF SURFACE. 1. ALL WORK SHALL CONFORM TO MECHANICAL CODE, BUILDING CODE ANDALL OTHER APPLICABLE CITY CODES AND REGULATIONS. 2. THE CONTRACTOR SHALL PAY FOR ALL PERMITS AND FEES. 3. CONTROL LOW VOLTAGE WIRING BY MECHANICAL CONTRACTOR AND CONDUIT BY ELECTRICAL CONTRACTOR. 4. CONDENSATE DRAIN PIPING AND FINAL CONNECTION TO UNIT BY PLUMBING CONTRACTOR. 5. G.C. TO VERIFY CURRENT ELECTRICAL POWER CONDITION IN FIELD BEFOREPURCHASING ANY MECHANICAL EQUIPMENT. 6. CONTRACTOR TO VERIFY MECHANICAL HEATING EQUIPMENT TO BECONFORM TO LOCAL EPA STANDARD BEFORE PURCHASING EQUIPMENT. 7. ACCURATE AS-BUILT DRAWINGS SHALL BE MADE DURING CONSTRUCTIONAND SUBMITTED FOR APPROVAL UPON COMPLETION OF INSTALLATION. 8. THE CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR FOR SIZE AND LOCATION OF DUCTWORK ROOF OPENINGS AND WITH ELECTRICAL CONTRACTOR FOR ELECTRICAL REQUIREMENTS OF ALL MECHANICAL EQUIPMENT AND ARCHITECTURAL DRAWINGS FOR AIR DISTRIBUTIONLOCATION. 9. THE CONTRACTOR SHALL SUBMIT BID BASED ON THE DRAWINGS ANDALTERNATE FOR COST SAVING. THESE DRAWINGS ARE FOR BIDDINGPURPOSES. 10. THE CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR, EQUIPMENT, TRANSPORTATION AND SERVICES NECESSARY FOR COMPLETION OF THE WORK. ALL MATERIALS AND WORK SHALL COMPLY WITH APPLICABLE CODES AND GOVERNING REGULATIONS AND MEET THE APPROVAL OF THE LOCAL JURISDICTION. 11. TAKE ALL PRECAUTIONS NECESSARY TO PROTECT THE MATERIALS BEFORE,DURING AND AFTER INSTALLATION. IN THE EVENT OF DAMAGE,IMMEDIATELY REPAIR ALL DAMAGED AND DEFECTIVE WORK TO THEAPPROVAL OF THE ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. 12. THESE DRAWINGS ARE DIAGRAMMATIC. THE CONTRACTOR SHALL BERESPONSIBLE FOR COORDINATING HIS WORK WITH ALL OTHER TRADES. THIS INCLUDES COORDINATING THE LOCATION AND SIZE OF ALL OPENINGS, LOCATIONS OF EQUIPMENT PADS AND CHANGES OF ELEVATIONS OF DUCTWORK, PIPING AND OTHER EQUIPMENT. 13. ANY MATERIAL, ARTICLE OR PIECE OF EQUIPMENT OTHER THAN THATINDICATED SHALL NOT BE USED UNLESS APPROVED IN WRITING BY THEENGINEER AND ANY CHANGES IN MECHANICAL, ELECTRICAL AND/OR OTHERSYSTEMS REQUIRED DUE TO SUCH SUBSTITUTION SHALL BE THERESPONSIBILITY OF THE HVAC CONTRACTOR; AND AT NO ADDITIONAL COSTTO THE OWNER. 14. THE CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING TO VERIFY LOCATIONS AND SIZES OF ALL EXISTING EQUIPMENT AND INFORM THE ARCHITECT AND ENGINEER OF ANY DISCREPANCIES. 15. CONTRACTOR TO VERIFY ADEQUATE PLUMBING CONNECTIONS AREREADILY AVAILABLE FOR EVAPORATIVE COOLERS AND GAS HEATINGSYSTEMS BEFORE PURCHASING EQUIPMENT. 16. COORDINATE ENTIRE INSTALLATION OF THE H.V.A.C. SYSTEM WITH THEWORK OF ALL OTHER TRADES PRIOR TO ANY FABRICATION ORINSTALLATION. PROVIDE ALL FITTINGS, OFFSETS, AND TRANSITIONS ASREQUIRED FOR A COMPLETE WORKABLE INSTALLATION. 17. CONTRACTOR SHALL SUBMIT A COMPLETE BALANCE REPORT FOR APPROVAL. SYSTEMS AIR BALANCE SHALL BE PERFORMED BY AN INDEPENDENT AIR BALANCE CONSULTANT. A CERTIFIED AABC OR NEBB.THE REPORT SHALL INCLUDE THE FOLLOWING:a. AIR QUANTITIES AT EACH REGISTER.b. STATIC PRESSURE READINGS AT INLET AND DISCHARGE OF EACHAIR HANDLING SYSTEM AND AT INLET OF EACH EXHAUST AIRSYSTEM.c. COOLING AND HEATING SUPPLY AND RETURN AIR TEMPERATURES AT EACH AIR CONDITIONING UNIT. 18. WARRANTIES; 1-YEAR WARRANTY FOR EQUIPMENT, 5-YEAR COMPRESSORS. REFER TO CONSTRUCTION CONTRACT FOR OTHER APPLICABLEWARRANTIES. 19. EQUIPMENT SPECIFICATION AND INTERLOCK DIAGRAM SHALL BESUBMITTED FOR APPROVAL PRIOR TO PURCHASE OF EQUIPMENT FORINSTALLATION. 20. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THEEQUIPMENT MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL FITTINGS, TRANSITIONS, DAMPERS, VALVES AND OTHER DEVICES REQUIRED FOR A COMPLETE WORKABLE INSTALLATION. 21. HEATING, VENTILATING, AND AIR-CONDITIONING SYSTEMS SHALL BE BALANCED BY A LICENSED T&B CONTRACTOR IN ACCORDANCE WITH ONEOF THE FOLLOWING METHODS (CMC 314.1): ·AABC NATIONAL STANDARDS FOR TOTAL SYSTEM BALANCE ·ACCA MANUAL B ·ASHRAE 111 ·NEBB PROCEDURAL STANDARDS FOR TESTING ADJUSTING BALANCINGOF ENVIRONMENTAL SYSTEMS ·SMACNA HVAC SYSTEMS TESTING, ADJUSTING AND BALANCING 22. PROVIDE FILTER FOR AIR CONDITIONING AND/OR AIR SIDE UNITS ASREQUIRED PER ASHRAE AND MECHANICAL CODE. 23. THERMOSTAT SHALL BE 24 VOLT, ONE STAGE HEATING AND ONE OR TWOSTAGE COOLING WITH MATCHING SUBBASE AND TAMPER PROOF COVER. 24. CONDENSATE PIPING SHALL BE SIZED IN ACCORDANCE WITH MECHANICAL CODE. 5.504.1 TEMPORARY VENTILATION: IF THE HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN AIR FILTERS WITH A MERV OF 8, BASED ON ASHRAE 52.2-1999, OR AN AVERAGE EFFICIENCY OF 30% BASED ON ASHRAE 52.1-1992. REPLACE ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY. APPLIES TO ADDITIONS ORALTERATIONS. 5.504.3 COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICALEQUIPMENT DURING CONSTRUCTION:AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THECONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING,COOLING AND VENTILATING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC,SHEET METAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF DUST, WATER ANDDEBRIS WHICH MAY ENTER THE SYSTEM. 5.504.5.3 FILTERS:IN MECHANICALLY VENTILATED BUILDINGS, PROVIDE REGULARLYOCCUPIED AREAS OF THE BUILDING WITH AIR FILTRATION MEDIA FOROUTSIDE AND RETURN AIR PRIOR TO OCCUPANCY THAT PROVIDES ATLEAST A MERV OF 13. 5.506.1 OUTSIDE AIR DELIVERY: FOR MECHANICALLY OR NATURALLY VENTILATED SPACES IN BUILDINGS, MEET THE MINIMUM REQUIREMENTS OF SECTION 120.1 OF THE CALIFORNIA ENERGY CODE AND CHAPTER 4 OF CCR, TITLE 8, OR THE APPLICABLELOCAL CODE, WHICHEVER IS MORE STRINGENT. 5.508.1.1. CHLOROFLUOROCARBONS ( CFCs):INSTALL HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT THATDO NOT CONTAIN CFCs. 5.508.1.2. HALONS:INSTALL HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT THAT DO NOT CONTAIN HALONS. CA GREEN BUILDING NOTES ADIMINISTRATIVE REQUIREMENTS: A. THE PERSON WITH OVERALL RESPONSIBILITY FOR CONSTRUCTION OR THEPERSON RESPONSIBLE FOR THE INSTALLATION OF REGULATED FEATURES,MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES SHALL POST, ORMAKE AVAILABLE WITH THE BUILDING PERMIT(S) ISSUED FOR THE BUILDING,THE REQUIRED INSTALLATION CERTIFICATE(S) FOR FEATURES, MATERIALS,COMPONENTS, OR MANUFACTURED DEVICES REGULATED BY THE APPLIANCE EFFICIENCY REGULATIONS OR PART 6. SUCH INSTALLATION CERTIFICATE(S) SHALL BE MADE AVAILABLE TO THE ENFORCEMENT AGENCY FOR ALL APPROPRIATE INSPECTIONS. THESE CERTIFICATES SHALL:A.1. IDENTIFY FEATURES, MATERIALS, COMPONENTS, ORMANUFACTURED DEVICES REQUIRED TO VERIFY COMPLIANCEWITH THE APPLIANCE EFFICIENCY REGULATIONS AND PART 6.A.2. INCLUDE A STATEMENT INDICATING THAT THE FEATURES,MATERIALS, COMPONENTS, OR MANUFACTURED DEVISECONFORM TO THE APPLIANCE EFFICIENCY REGULATIONS AND PART 6 AND THE REQUIREMENTS FOR SUCH FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES GIVEN IN THE PLANS AND SPECIFICATIONS APPROVED BY THELOCAL ENFORCEMENT AGENCY.A.3. STATE THE NUMBER OF THE BUILDING PERMIT UNDER WHICHTHE CONSTRUCTION OR INSTALLATION WAS PERFORMED. B. WITHIN 90 DAYS AFTER ISSUANCE OF CERTIFICATE OF OCCUPANCYRECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER. IF A BUILDINGDESIGN FEATURE, MATERIAL, COMPONENT OR MANUFACTURED DEVICE IS CHANGED BEFORE FINAL CONSTRUCTION AND INSTALLATION, SUCH THAT THE BUILDING MAY NO LONGER COMPLY WITH PART 6, THE BUILDING MUST BE BROUGHT INTO COMPLIANCE, AND SO INDICATED ON AMENDED PLANS AND CERTIFICATE OF COMPLIANCE(S) THAT SHALL BE SUBMITTED FORAPPROVAL. C. THE BUILDER SHALL PROVIDE THE BUILDING OWNER OR THE PERSON(S)RESPONSIBLE FOR BUILDING MAINTENANCE (IN CASE OF MULTI-TENANT ORCENTRALLY OPERATED BUILDINGS) AT OCCUPANCY THE FOLLOWING: C.1. OPERATING INFORMATION: THE APPROPRIATE CERTIFICATE(S) OF COMPLIANCE AND A LIST OF THE FEATURES, MATERIALS, COMPONENTS, AND MECHANICAL DEVICES INSTALLED IN THE BUILDING AND INSTRUCTIONS ON HOW TO OPERATE THEM EFFICIENTLY. C.2. MAINTENANCE INFORMATION: REQUIRED ROUTINEMAINTENANCE ACTIONS SHALL BE CLEARLY STATED ANDINCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABELMAY BE LIMITED TO IDENTIFYING THE OPERATION ANDMAINTENANCE MANUAL. C.3. VENTILATION INFORMATION: A DESCRIPTION OF THE QUANTITIES OF OUTDOOR AND RECIRCULATED AIR THAT THE VENTILATION SYSTEMS ARE DESIGNED TO PROVIDE TO EACH AREA. MANDATORY MEASURES: A. (IF APPLICABLE) MANUFACTURED FENESTRATION AND EXTERIOR DOORSSHALL MEET ALL LISTED REQUIREMENTS IN SEC 10-111-(A) UNDER SECTION110.6(A) OF PART 6. TEMPORARY LABELS FOR MANUFACTUREDFENESTRATION SHALL HAVE A CLEARLY VISIBLE TEMPORARY LABEL ANDSHALL COMPLY WITH LABELING REQUIREMENTS OF NFRC 700. NO OTHERVALUES FOR U-FACTOR, SHGC, VT AND AIR LEAKAGE ARE ALLOWED ON THE TEMPORARY LABEL ATTACHED TO THE MANUFACTURED FENESTRATION PRODUCT OR EXTERIOR DOOR. B. (IF APPLICABLE) RATED FENESTRATION SHALL HAVE A PERMANENT LABEL CONSISTENT WITH THEIR RATING AND CERTIFICATION THAT IS EITHER ASTAND-ALONE LABEL, AN EXTENSION OR TAB OF AN EXISTING PERMANENTCERTIFICATION LABEL BEING USED BY THE MANUFACTURER/RESPONSIBLEPARTY, OR A SERIES OF MARKS OR ETCHINGS ON THE PRODUCT. C. JOINTS, PENETRATIONS AND OTHER OPENINGS IN THE BUILDING ENVELOPETHAT ARE POTENTIAL SOURCES OF AIR LEAKAGE SHALL BE CAULKED,GASKETED, WEATHER STRIPPED, OR OTHERWISE SEALED TO LIMIT INFILTRATION AND EXFILTRATION. D. ALL INSULATING MATERIAL SHALL BE INSTALLED IN COMPLIANCE WITH THE FLAME-SPREAD RATING AND SMOKE DENSITY REQUIREMENTS OF THE CBC. E. NON-CENTRALIZED ENERGY MANAGEMENT SYSTEMS SHALL HAVE SETBACKTHERMOSTATS; CAPABLE TO PROGRAM TEMPERATURE SETPOINTS FOR ATLEAST FOUR PERIODS WITHIN A 24-HR. PERIOD. F. ALL RECIRCULATED AIR OR OUTDOOR AIR SUPPLIED TO OCCUPIABLESPACES IS FILTERED (MINIMUM MERV 13) BEFORE PASSING THROUGH ANYAIR CONDITIONING COMPONENT; THE LESSER OF THE MINIMUM RATE OF OUTDOOR AIR REQUIRED BY SEC. 120.1 (C), OR THREE COMPLETE AIR CHANGES SHALL BE SUPPLIED TO THE ENTIRE BUILDING DURING THE ONE-HOUR PERIOD IMMEDIATELY BEFORE THE BUILDING IS NORMALLY OCCUPIED. G. ALL MECHANICAL VENTILATION AND SPACE-CONDITIONING SYSTEMS SHALLBE DESIGNED WITH DUCTWORK, DAMPERS, AND CONTROLS WHICH ALLOWSOUTSIDE AIR RATES TO BE OPERATED AT THE LARGER OF (1) THE MINIMUMLEVELS SPECIFIED IN SECTION 120.1(C)3 OR (2) THE RATE REQUIRED FORMAKE-UP OF EXHAUST SYSTEMS THAT ARE REQUIRED FOR AN EXEMPT ORCOVERED PROCESS, FOR CONTROL OF ODORS, OR FOR THE REMOVAL OF CONTAMINANTS WITHIN THE SPACE. MEASURED OUTSIDE AIR RATES OF CONSTANT AND VARIABLE VOLUME MECHANICAL VENTILATION SYSTEMS SHALL BE WITHIN 10% OF OUTSIDE AIR RATE SHOWN ON TABLE 120.1-A. H. THE THERMOSTATIC CONTROLS FOR HVAC SYSTEMS SHALL BE CAPABLE OFBEING SET LOCALLY OR REMOTELY BY TO CONTROL COMFORT HEATINGDOWN TO 55 °F OR LOWER AND COOLING UP TO 85°F OR HIGHER. THETHERMOSTATIC CONTROLS SHALL BE CAPABLE OF PROVIDING A DEADBAND RANGE OF AT LEAST 5 °F WITHIN WHICH HEATING AND COOLINGENERGY TO THE ZONE IS SHUT OFF OR REDUCE TO A MINIMUM. I. OUTDOOR AIR SUPPLY AND EXHAUST EQUIPMENT SHALL BE INSTALLED WITH DAMPERS THAT AUTOMATICALLY CLOSE UPON FAN SHUTDOWN. J. AIR DISTRIBUTION SYSTEM DUCTS AND PLENUMS, INCLUDING, BUT NOT LIMITED TO, BUILDING CAVITIES, MECHANICAL CLOSETS, AIR-HANDLERBOXES AND SUPPORT PLATFORMS USED AS DUCTS OR PLENUMS, SHALL BEINSTALLED, SEALED AND INSULATED TO MEET THE REQUIREMENTS OFCHAPTER 6 CMC CODE AND ANSI/SMACNA -006-2006 HVAC DUCTCONSTRUCTION STANDARDS METAL AND FLEXIBLE. SUPPLY-AIR DUCTSCONVEYING HEATED OR COOLED AIR SHALL BE INSULATED TO A MINIMUM INSTALLED LEVEL OF R-4.2 (R-8 IN UNCONDITIONED SPACE), UNLESS DUCTS ARE IN CONDITIONED SPACE. K. MAXIMUM LENGTH OF FLEXIBLE DUCT AND CONNECTORS SHALL NOT BE MORE THAN 5 FEET. FLEXIBLE DUCTS SHALL NOT BE USED IN LIEU OF RIGIDELBOWS. L. EACH SPACE-CONDITIONING SYSTEM SHALL BE INSTALLED WITH CONTROLS(1) CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SYSTEM DURINGPERIODS OF NON-USE AND SHALL HAVE (A) 4-HR TIMER OR; (B) OCCUPANCYSENSORS OR; (C) AUTO TIME SWITCH CONTROLS AND ACCESSIBLE MANUALOVERRIDE FOR UP TO 4-HRS. (2) AUTOMATICALLY RESTART AND TEMPORARILY OPERATE THE SYSTEM TO MAINTAIN SETBACK THERMOSTAT SETPOINTS FOR MECHANICAL HEATING AND COOLING. (3) MULTIPURPOSE, CLASSROOMS CONFERENCE, CONVENTION, AUDITORIUM AND MEETING CENTER ROOMS OF CERTAIN SIZE WHICH DO NOT HAVE PROCESSES OROPERATIONS THAT GENERATE DUSTS, FUMES, VAPORS OR GASSES SHALLBE EQUIPPED WITH OCCUPANT SENSOR(S) TO ACCOMPLISH THEFOLLOWING DURING UNOCCUPIED PERIODS (A) AUTOMATICALLY SETUP THEOPERATING COOLING TEMPERATURE SET POINT BY 2°F OR MORE ANDSETBACK THE OPERATING HEATING TEMPERATURE SET POINT BY 2˚F OR MORE AND; (B) AUTOMATICALLY RESET THE MINIMUM REQUIRED VENTILATION RATE WITH AN OCCUPANT SENSOR VENTILATION CONTROL DEVICE ACCORDING TO SECTION 120.1(C)5. (4) HOTEL AND MOTEL GUEST ROOMS SHALL HAVE CAPTIVE CARD KEY CONTROLS, OCCUPANCY SENSINGCONTROLS, OR AUTOMATIC CONTROLS SUCH THAT, NO LONGER THAN 30MINUTES AFTER THE GUEST ROOM HAS BEEN VACATED, SETPOINTS ARESETUP AT LEAST +5°F (+3°C) IN COOLING MODE AND SET-DOWN AT LEAST-5°F (-3°C) IN HEATING MODE. CA TITLE 24 NOTESHVAC GENERAL NOTES LESS THAN 12 26/.022 .025 13-30 26/.022 .025 31-36 24/.023 .026 FOOTNOTES: FOR GALVANIZED STEEL (SMACNA TABLE 1-4/E5) MAXIMUM 1" W.G. STATIC POSITIVE AND NEGATIVE DUCT GAUGE SELECTIONS MINIMUM THICKNESSALUMINUM (INCHES)MINIMUM THICKNESSGALVANIZED IRON (U.S.GAUGE/INCHES) DUCT DIAMETER(INCHES) 1. HEATING AND AIR CONDITIONING UNITS NOT EXCEEDING 2000 CFM OR ONE INCHWATER GAUGE (WG) POSITIVE OR NEGATIVE PRESSURE. DUCT FITTINGS SHALL BE CONSTRUCTED OF MATERIAL NOT LESS THAN THE GAUGE OF THE DUCT.2. DUCTWORK AND FITTINGS LARGER THAN TWENTY INCHES SHALL BECONSTRUCTED TO THE GAUGING REQUIREMENTS OF ANSI SMACNA 006-2006HVAC DUCT CONSTRUCTION STANDARDS. MECHANICAL CODE ·2022 CMC ·2022 BUILDING ENERGY EFFICIENCY STANDARDS SCOPE OF WORK 2022 BUILDING ENERGY EFFICIENCY STANDARDS SECTION 120.1(D)4 A. For each system with demand control ventilation (DCV), CO2 sensors shall be installed in each room that meets the criteria of Section 120.1(d)3 with no less than one sensor per 10,000 ft² of floor space. When a zone or a space is served by more than one sensor, a signal from any sensor indicating that CO2 is near orat the setpoint within the zone or space shall trigger an increase in ventilation. B. CO2 sensors shall be located in the room between 3 ft and 6 ft above the floor orat the anticipated height of the occupants’ heads. C. Demand ventilation controls shall maintain CO2 concentrations less than or equalto 600 ppm plus the outdoor air CO2 concentration in all rooms with CO2 sensors. EXCEPTION to Section 120.1(d)4C: The outdoor air ventilation rate is not requiredto be larger than the design outdoor air ventilation rate required by Section 120.1(c)3 regardless of CO2 concentration. D. Outdoor air CO2 concentration shall be determined by one of the following: D.A. CO2 concentration shall be assumed to be 400 ppm without any directmeasurement; or D.B. CO2 concentration shall be dynamically measured using a CO2 sensorlocated within 4 ft of the outdoor air intake. E. When the system is operating during hours of expected occupancy, the controls shallmaintain system outdoor air ventilation rates no less than the rate listed in Table 120.1-Afor DCV, times the conditioned floor area for spaces with CO2 sensors, plus the raterequired by Section 120.1(c)3 for other spaces served by the system, or the exhaust airrate whichever is greater. F. CO2 sensors shall be certified by the manufacturer to be accurate within plus orminus 75 ppm at a 600 and 1000 ppm concentration when measured at sea level and 25°C, factory calibrated, and certified by the manufacturer to require calibration no more frequently than once every 5 years. Upon detection of sensor failure, the system shall provide a signal which resets to supply the minimum quantity of outside air to levels required by Section 120.1(c)3 to the zone serviced by the sensor at all times that thezone is occupied. G. The CO2 sensor(s) reading for each zone shall be displayed continuously, and shallbe recorded on systems with DDC to the zone level. DEMAND CONTROL VENTILATION NOTES RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 2/28/2024 9:44:06 AM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: PL A N C H E C K R E V . 0 1 / 2 9 / 2 0 2 4 M000 MECHANICAL NOTES C.B. R.C. AIR DEVICE SCHEDULE MARK FACESIZE TYPE MOUNTINGTYPE DIRECTION MANUF.NOTES S-1 24X24 SUPPLY SURFACE/LAY-IN 4-WAY TITUS(OR EQUIV.)1,2,3,4 S-2 12X12 SUPPLY SURFACE/LAY-IN 4-WAY TITUS (OR EQUIV.)1,2,3,4 S-3 ROUND SUPPLY DUCTMOUNTED RADIAL TITUS(OR EQUIV.)1,2,3,4 R-1 -RETURN SURFACE/LAY-IN 1-WAY TITUS(OR EQUIV.)1,2,3 R-2 - RETURN DUCT MOUNTED 1-WAY TITUS (OR EQUIV.)1,3 T-1 - TRANSFER WALLMOUNTED 1-WAY TITUS (OR EQUIV.)1,2,3 NOTES: 1. PROVIDE NECESSARY MOUNTING HARDWARE AND ACCESSORIES AS REQUIRED. 2. ALL AIR DEVICES SHALL HAVE MANUFACTURER-APPLIED STANDARD WHITE FINISHUNLESS NOTED OTHERWISE. REFER TO ARCHITECTURAL DRAWINGS FOR RCPCOORDINATION. 3. AIR DEVICE SHALL BE OF STEEL CONSTRUCTION. 4. AIR DEVICE SHALL BE INSTALLED COMPLETE WITH MANUFACTURER AVAILABLE MOLDED INSULATION BACKING. FIELD-FABRICATED INSULATION BACKING IS NOTALLOWED UNLESS FIRST APPROVED BY THE OWNER'S CONSTRUCTION MANAGER. FAN SCHEDULE MARK EQUIP.CFM SP. (W.G.)RPM HP FLA MOTOR (ELEC) SONES (DB) WT (LBS)MANUFACTURER &MODEL NO.REMARKS EF - 1 RESTROOM EXHFAN 110 0.1"- 7.7W 0.1 120/1 0.3 12.3 BROAN XB110 1,2,3 REMARKS: 1 EQUIVALENT ACCEPTABLE. 2 INSTALL WITH BACK DRAFT DAMPER. 3 ELECTRICALLY INTERLOCKED WITH LIGHT SWITCH WITH MANUAL OVER-RIDE SWITCH. # EF GRAVITY VENTILATOR SCHEDULE MARK EQUIP.CFM THROAT WIDTH XLENGTH CURB CAP WIDTH XLENGTH WT(LBS)MANUFACTURER &MODEL NO.REMARKS GV -1 GRAVITY INTAKE 2041 20 X 20 26 X 26 61 GREENHECK FGI 1,2,3 REMARKS: 1 EQUIVALENT ACCEPTABLE. 2 INSTALL WITH BACKDRAFT DAMPER. 3 ROOF CURB WITH 1/4" SCREEN. # GV EXHAUST FAN SCHEDULE MARK EQUIP.CFM SP.(W.G.)RPM HP MOTOR(ELEC) WT (LBS)MANUFACTURER & MODEL NO.CAN- FILTER REMARKS MANUFACTURE AREAEXHAUST FAN 1019 0 2990 228 W 120/1 - CAN-FANMAX-FAN 10"CAN-LITE 10''1500CFM 1,2,3 REMARK: 1. INSTALLED BY GENERAL CONTRACTOR. 2. INSTALL WITH BACKDRAFT DAMPER. 3. ACTIVATED BY CO2 SENSOR. 1 CF PACKAGED ROOFTOP HEAT PUMP UNIT SCHEDULE MARK MAKE &MODEL NOMINALTONS COOLING CAPACITY(BTUH)HEATINGCAPACITY(BTUH)HSPF/COP SUPPLY FAN POWER SUPPLY EER2/SEER2/IEER2 WEIGHT(LBS.)UNIT DIMENSIONS (IN.) (EQUIV.ACCEPTABLE)TH SH CFM HP VOLT PH HZ MCA/ MOCP H W D RTU -1 EXISTING 3.5 --- -1,400 - - - - ---- - - RTU -2 EXISTING 4 --- -1,600 - - - - ---- - - RTU -3 TRANE WSC060 5 61,000 48,800 59,000 7.2 / -2,000 1 208 3 60 31 / 45 10.6 / 13.4 / -1003 40-7/8 88-5/8 53-1/4 RTU -4 TRANE WSC060 5 61,000 48,800 59,000 7.2 / -2,000 1 208 3 60 31 / 45 10.6 / 13.4 / -1003 40-7/8 88-5/8 53-1/4 NOTES: 1 INSTALL WITH DISCONNECT SWITCH AND ALL WEATHERPROOF GFCI. 2 THERMOSTATS INSTALLED AT 48"AFF W/ REMOTE SENSORS. 3 PROVIDE STANDARD THROWAWAY CONSTRUCTION FILTERS OF MERV 13. MECHANICAL CONTRACTOR SHALL FURNISH AND FIELD INSTALL NEW FILTER PRIOR TO BUILDING OCCUPANCY (INCLUDING FOR INTERNAL PRESSURE DROP. 4 EXTEND CONDENSATE DRAIN DIRECTLY TO A LOCAL CODE APPROVED RECEPTOR. 5 PROVIDE REMOTE ALARM INDICATORS FOR THE SUPPLY AIR SMOKE DETECTORS CLEARLY LABELED AS TO FUNCTION AND UNIT SERVED. 6 DUCT SMOKE DETECTORS SHALL BE PROVIDED FOR SYSTEMS HAVING A GREATER THAN 2,000 CFM CAPACITY ON SUPPLY PLENUM. KEYED REMOTE TEST SWITCHES WITH LED LIGHT INDICATOR ARE TO BE PROVIDED ON THE WALL AT NO GREATER THAN 6 FEET FOR ALL DUCT DETECTORS. DUCT DETECTOR ACTIVATION SHALL RESULT IN COMPLETE SHUT DOWN OF HVAC UNITS AND NOTIFICATION TO THE FIRE ALARM SYSTEM IN THE FORM OF A SUPERVISORY SIGNAL. 7 EACH COOLING AIR HANDLER THAT HAS A DESIGN TOTAL MECHANICAL COOLING CAPACITY OVER 33,000 BTU/HR SHALL INCLUDE AN AIR ECONOMIZER CAPABLE OFMODULATING OUTSIDE-AIR AND RETURN-AIR DAMPERS TO SUPPLY 100 PERCENT OF THE DESIGN SUPPLY AIR QUANTITY AS OUTSIDE AIR. INSTALL WITH A FAULTDETECTION AND DIAGNOSTICS (FDD) SYSTEM. # RTU RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 2/28/2024 9:44:25 AM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: PL A N C H E C K R E V . 0 1 / 2 9 / 2 0 2 4 M001 MECHANICAL SCHEDULES C.B. R.C. N.T.S. SCALE:CEILING DIFFUSER DETAIL MAIN TRUNK DUCT ROUND OR RECTANGULAR INSULATED SUPPORT END OF RIGID DUCT FROMSTRUCTURE NYLON BAND OVER INSULATION (TYPICAL) HIGH EFFICIENCY TAKEOFF EXTERNALLY INSULATED WITH VOLUME DAMPER AND DAMPER LOCK WITH EXTENSION SEE NOTES PRE-INSULATED FLEXIBLE DUCTWORK. SEE SPECIFICATIONS. LENGTH NOT TO EXCEED 5'-0". PROVIDE SUPPORT PER SMACNA STANDARDS. INSTALL PERMANENTLY SEALED TO PREVENTKINKING, SHARP TURNS AND SAGS. METAL BAND (TYPICAL) CEILING DIFFUSER AS PERMECHANICAL SCHEDULEDCEILING LINE NOTE: EXTEND HARD METAL DUCT SO THAT MAXIMUM FLEXIBLE DUCT LENGTH DOES NOT EXCEED 5'-0". PROVIDE RIGID 90° ELBOW WHERE REQUIRED TO KEEP FLEXIBLE DUCT WITHIN 5'-0" LENGTH LIMITATION. 2 N.T.S. SCALE:CEILING EXHAUST FAN DETAIL 1. WALL AND/OR ROOF PENETRATIONS SHALL BEPROVIDED WITH WEATHER TIGHT SEAL;COORDINATE WITH GENERAL CONSTRUCTION. 2. INSTALL MINIMUM 15 GAUGE SHEET STEELSUPPORTS TO RIGIDLY ATTACH FAN HOUSINGTO STRUCTURE; FIELD VERIFY EXACT REQUIREMENTS. INSURE ADEQUATE VIBRATION ISOLATION. 3. INSTALLATION SHALL BE NEAT ANDCOMPLETED TIMELY AND IN SUCH A MANNER TO ALLOW CONTRACTOR TO FINISH SURFACES UNIFORMLY. 4. ALL ELECTRICAL WIRING AND CONNECTIONS SHALL BE BY ELECTRICAL CONTRACTOR. INSULATION NOTES: BACKDRAFT DAMPER INSULATED HOUSING MOTOR DUCT DEFENDER FIRE DAMPER (IF REQUIRED)WALL CAP W/BACKDRAFTDAMPER WALL CONSTRUCTION(BY OTHERS) DUCT TRANSITION REQUIRED ROOF STRUCTURE ROOF CAP DUCT CEILING EXHAUST FAN (CEF) DUCTADAPTER CEILING (BY OTHERS)GRILLE (BY MANUFACTURER) 4DUCT MOUNTING DETAIL SCALE NTS ROUND DUCT RECTANGULAR DUCT 1 PROVIDE 10" FLEX. CONNECTOR COPPER TUBING WITH WROUGHTCOPPER FITTINGS A/C. UNIT 6" MIN. SECONDARY OR OVERFLOWDRAIN, SHALL TERMINATETHRU FINISHED CEILING, SOFFIT OR WALL (LOCATED AT VISIBLE LOCATION) BRASS CLEANOUT PLUG(THREADED) PIPING SEE PLANSFOR CONTINUATION OF 3" MIN. UNION FORTRAPREMOVAL BRASS CLEANOUT PLUG (THREADED) UNION (DI-ELECTRIC WHERE STEEL MEETS COPPER) DRAIN LINE SHALL BE AT LEAST THE SAME SIZE AS THE NIPPLE ON THE DRAIN PAN 1. 2. NOTES: DRAIN PAN ALL CONDENSATE DRAIN LINES INSIDE BUILDING SHALL BE INSULATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE PLUMBING CODE. TRAP DEPTH SHALL BE EQUAL TO THE UNIT TOTAL STATIC PRESSURE PLUS 1-INCH BUTNOT LESS THAN 3-INCHES. N.T.S. SCALE:CONDENSATE DRAIN DETAIL 3 4X6 WD. BEAM W/ SIMPSON JST HANGERS EA. END TO (E) TJI TOP OF CURB TO REMAIN LEVEL HVAC CURB SEE MECH. DWGS. RIGID INSULATION PANEL SECURE TO A/C UNIT (4) No. 10 X 1/2" TEK SCREWS (MINIMUM) BLOCK AS REQUIRED TOMAINTAIN CONSISTENT BEARING WOOD NAILER SECURE BRACKET TO CURB (4) No. 10 X 1/2" TEK SCREWS (MINIMUM) 4" FIBER CANT STRIP, TYP. 1/2" Ø LAG SCREWS AT 24" O.C. (MIN. 2PER SHORT SIDE) W/ 4" EMB. TYP. (E) MODIFIED BITUMINOUS ROOFING MEMBRANE O/ (E)PLYWOOD SHTG. PATCH ANDREPAIR ROOFING ASREQUIRED TO PROVIDE ALEAK PROOF CONDITION6" MIN. MODIFIED BITUMINOUSBASE FLASHING SEISMIC BRACKET FURNISHED BY UNIT MANUFACTURE SIZE AND QUANITY TO BE DETERMINED BY UNIT MFGR. RETURN SUPPLY COMPRESSOREND 14" MIN. 20" MAX. SLOPING ROOF CURB 7-1/ 2 " 6" X 16 GAUGE HOLD-DOWN CLIP FURNISHED BY UNIT MANUFACTURER 16 GAUGE STIFFENER AS REQUIRED BY UNIT MANUFACTURER #10 X 1/2" TEK SCREWS (12 MINIMUM PER CLIP) N.T.S. SCALE:ROOFTOP UNIT ANCHORAGE DETAIL NOTE: FOR OTHER MANUFACTURERS CONSULT MANUFACTURER'S INSTALLATION INSTRUCTION 5 RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 2/28/2024 9:44:21 AM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: PL A N C H E C K R E V . 0 1 / 2 9 / 2 0 2 4 M002 MECHANICAL DETAILS C.B. R.C. MECHANICAL PLAN 1.IF DRAWINGS ARE INCORRECT FROM THE ACTUAL SITE CONDITION, CONTRACTOR SHALL NOTIFY ENGINEER(S) AND PROVIDE INFORMATIONREFLECTING ACTUAL CONDITIONS. 2. ENVIRONMENTAL EXHAUST TERMINATION TO BE MINIMUM 3 FEET FROM APROPERTY LINE, 10 FEET FROM A FORCED AIR INLET, AND 3 FEET FROM OPENINGS INTO THE BUILDING. 1. INSTALL DUCT SMOKE DETECTOR ON SUPPLY SIDE PLENUM. 2. INSTALL PROGRAMMABLE THERMOSTAT 48"AFF AND MOUNT REMOTE SENSORS HIGH ON WALL. 3. P.O.C. TO EXISTING SUPPLY DUCT FROM RTU-2. FIELD VERIFY ALL EXISTINGCONDITIONS SIZE AND LOCATIONS PRIOR TO START OF THIS WORK. 4. P.O.C. TO EXISTING RETURN DUCT FROM RTU-2. FIELD VERIFY ALL EXISTINGCONDITIONS SIZE AND LOCATIONS PRIOR TO START OF THIS WORK. 5. 6'' EXHAUST VENT TO ROOF. #KEYED PLAN NOTES: GENERAL NOTES: S - 1 400 (TYP. 5) S - 1 650 (TYP. 2) S - 3 350 (TYP. 2) R - 1 600 R - 2 600 S - 1 150 S - 1 100 S - 1 250 S - 1 100 S - 1 500 S - 1 250 S - 2 50 S - 1 200 S - 1 350 S - 2 50 R - 1 50 R - 1 300 R - 1 200 R - 1 50 R - 1 200 R - 1 100 R - 1 400 R - 1 150 2 T3 2 S3 2 T4 2 S4 2T12S1 1CF 1CF 1CF 1CF 1GV 1GV 1 1 3 4 1RTU 4 RTU 3 RTU 1 EF 1 EF CO2 5 10"Ø 10"Ø 18"Ø 14"Ø 10"Ø 18"Ø 12"Ø 12"Ø 14"Ø 14"Ø 14"Ø 16"Ø 12"Ø 18"Ø 10"Ø 8"Ø 6"Ø 10"Ø 12"Ø 6"Ø 12"Ø 6"Ø 6"Ø 6"Ø 8"Ø 10"Ø 10"Ø 6"Ø 16"Ø 16"Ø 12"Ø 10"Ø 6"Ø6"Ø 8"Ø 10"Ø 8"Ø 12"Ø 14"Ø 12"Ø 10"Ø 12"Ø 12"Ø (TYP. 2) 16"Ø R - 1 875 (TYP. 2) 14"Ø 18"Ø T - 1 - RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 2/28/2024 9:44:10 AM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: PL A N C H E C K R E V . 0 1 / 2 9 / 2 0 2 4 M100 1/4" = 1'-0" MECHANICAL PLAN C.B. R.C. MECHANICAL PLAN - ROOF PLAN 1.IF DRAWINGS ARE INCORRECT FROM THE ACTUAL SITE CONDITION, CONTRACTOR SHALL NOTIFY ENGINEER(S) AND PROVIDE INFORMATION REFLECTING ACTUAL CONDITIONS. 1. RESTROOM EXHAUST TERMINATION. MINIMUM 3 FEET FROM A PROPERTY LINE, 10 FEET FROM A FORCED AIR INLET, AND 3 FEET FROM OPENINGS INTOTHE BUILDING. 2. CONDENSATION PIPE DISCHARGE BY DIRECT CONNECTION TO LAVTAILPIECE. CONDENSATE DRAIN SLOPE AT MIN. 1%. GENERAL NOTES: #KEYED PLAN NOTES: RTU3 RTU2 EXISTING SKYLIGHT (TYP.) 1 RTU 4RTU 1GV 1 GV (E) (E) 1 3/4"CD 2 CD CD CD CD CD CD CD CD CD CD 3/4"CD 3/4"CD 3/4"CD 3/4"CD 16"Ø 16"Ø (E) (E) EXISTING RETURN DUCT ON ROOF EXISTING SUPPLY DUCT ON ROOF 10 ' - 0 " 2' HEIGHT EXISTING PARAPET10 ' - 0 " RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 2/28/2024 9:44:28 AM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: PL A N C H E C K R E V . 0 1 / 2 9 / 2 0 2 4 M101 1/4" = 1'-0" MECHANICAL PLAN - ROOF PLAN C.B. R.C. MECHANICAL TITLE 24 - 1 RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 2/28/2024 9:44:17 AM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: PL A N C H E C K R E V . 0 1 / 2 9 / 2 0 2 4 TM00 MECHANICAL TITLE 24 - 1 C.B. R.C. MECHANICAL TITLE 24 - 2 RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 2/28/2024 9:44:13 AM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: PL A N C H E C K R E V . 0 1 / 2 9 / 2 0 2 4 TM01 MECHANICAL TITLE 24 - 2 C.B. R.C. GENERAL NOTES 1. BEFORE COMMENCEMENT OF WORK, THE CONTRACTOR SHALL VERIFY THE EXACTLOCATIONS, ELEVATIONS AND CHARACTERISTICS OF ALL UTILITIES AND PIPING, ANDSHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 2. THE PLUMBING SYSTEM DESIGN, INSTALLATION AND MATERIALS SHALL CONFORM TOTHE 2022 CPC AND AUTHORITIES HAVING JURISDICTION. IN CASE OF CONFLICTS WITH CODES, DRAWINGS, OR SPECIFICATIONS, THE MOST STRINGENT SHALL PREVAIL. 3. THE DRAWINGS WERE PREPARED WITH THE BEST STRUCTURAL AND ARCHITECTURAL INFORMATION AVAILABLE. IT IS UNDERSTOOD THAT EQUIPMENTLOCATIONS AND ROUTING OF PIPING MAY VARY FROM THAT SHOWN ON THE PLANSAS CONSTRUCTION PROCEEDS. IT IS THE CONTRACTORS RESPONSIBILITY TO: a. NOTIFY THE MECHANICAL ENGINEER OF CONSTRUCTION RESTRAINTS WHICHMAKE VARIATIONS FROM THE PLANS NECESSARY. b. COMPLETE ALL WORK INCLUDING THE VARIATIONS WITHOUT CHARGING EXTRASTO THE BID CONTRACT. COMPLETION OF WORK MEANS THE JOB IS WORKING AND MEETS ALL CITY, COUNTY AND UNIFORM MECHANICAL, PLUMBING AND BUILDING CODE REQUIREMENTS. 4. THESE DRAWINGS DO NOT INCLUDE ALL NECESSARY SAFETY REQUIREMENTS. CONTRACTOR TO COMPLY TO THE SAFETY REQUIREMENTS SET FORTH BY THELOCAL AUTHORITIES HAVING JURISDICTION. 5. THESE DRAWINGS ARE FOR BIDDING PURPOSES ONLY. THEY ARE ESSENTIALLYDIAGRAMMATIC TO THE EXTENT THAT MANY OFFSETS, BONDS, UNIONS, SPECIFICFITTINGS AND EXACT LOCATIONS ARE NOT INDICATED. 6. THE PLUMBING CONTRACTOR SHALL PROVIDE THE WATER, SEWER AND STORMDRAIN SYSTEMS AND CONNECT TO EACH DESIGNATED POINT OF CONNECTIONS 5'-0" OUTSIDE OF THE BUILDING. ALL SEWER SYSTEM SHALL MEET THE REQUIRED INVERT ELEVATION SHOWN ON THE CIVIL DRAWINGS. PIPING BEYOND THIS POINT IS SPECIFIED UNDER ANOTHER SECTION OF THE SPECIFICATION AND SHALL BE ASSHOWN ON THE CIVIL DRAWINGS. 7. THE OWNER SHALL MAKE ALL ARRANGEMENTS WITH UTILITY COMPANIES FORSERVICE AND CONNECTION AND SHALL MAKE APPLICATION FOR SERVICE ANDPERMITS AND SHALL PAY ALL FEES AND CHARGES INCLUDING THE COST OF VAULTSAND METERS. 8. ALL PLUMBING WORK SHALL BE INSTALLED SO AS TO AVOID INTERFERENCE WITH ELECTRICAL EQUIPMENT, MECHANICAL EQUIPMENT AND STRUCTURAL FRAMING, SKYLIGHT, ETC. 9. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILING ACCESS PANELS WITH THE ARCHITECTURAL REFLECTED CEILING PLAN AND ELECTRICALLIGHTING PLAN. 10. COORDINATE ALL LOCATIONS, SIZES AND ELEVATIONS OF ALL SLEEVES THROUGHWALLS, BEAMS, SLABS AND FOOTING WITH STRUCTURAL AND ARCHITECTURALDRAWINGS. ALL PIPES SLEEVING THROUGH FOOTINGS SHALL HAVE A SLEEVEDIAMETER OF TWO PIPE SIZES OVER THE PIPE PASSING THROUGH THE FOOTING. 11. CONTRACTOR MUST NOT CUT, RELOCATE, COMPROMISE, DAMAGE OR OTHERWISE ALTER THE ROOF STRUCTURE. THE JOISTS WHICH OCCUR THROUGHOUT ALL THE MECH. BAY AREAS LIKE WISE MUST NOT BE ALTERED. 12. BEFORE FABRICATION OR INSTALLATION, THE CONTRACTOR SHALL VERIFY EXACTLOCATIONS OF ALL MECHANICAL EQUIPMENT AND EQUIPMENT PROVIDED UNDERANOTHER SECTION OF SPECIFICATIONS. EXACT ROUGH-IN LOCATIONS ANDREQUIREMENTS SHALL BE COORDINATED IN FIELD. 13. CONNECTION BETWEEN INCOMPATIBLE MATERIALS ABOVE GRADE AND INSIDEBUILDING SHALL BE MADE WITH TWO (2) DIELECTRIC UNIONS SEPARATED BY ATWELVE INCH (12") SECTION OF RED BRASS PIPE. 14. ALL FLOOR AND WALL PENETRATIONS MUST BE SEALED WATERTIGHT AND VERMIN PROOF. 15. ALL EXTERIOR GAS COCKS, WATER SHUTOFF VALVES AND/OR SEWER CLEAN OUTS BELOW GROUND SHALL BE INSTALLED IN YARD BOXES WITH THE COVERSCONSPICUOUSLY MARKED "GAS", "WATER", AND "SEWER" RESPECTIVELY. 16. EXACT LOCATIONS AND MOUNTING HEIGHTS OF PLUMBING FIXTURES SHALL BEOBTAINED FROM THE ARCHITECTURAL DRAWINGS. PLUMBING FIXTURE SCHEDULE MARK ITEM HW CW VENT WASTE DESCRIPTION WC TANK TYPE WATER CLOSET -- 3/4" 2"4"AMERICAN STANDARD CADET PRO ELONGATED ADA COMPLIANT TANK WATER CLOSET WITH OPEN FRONT ELONGATED TOILET SEAT. 1.28 GPF. EQUIVALENT ACCEPTABLE. LAV WALL MOUNTED LAVATORY 1/2" 1/2"2"2" AMERICAN STANDARD 0356.041 SINK W/ 6055.165. SELECTRONIC PROXIMITY FAUCET. 0.5 GPM. ADACOMPLIANT. EQUIVALENT ACCEPTABLE. INSTALL WITH POWERS #LFG480 MIXING VALVE(ASSE 1070LISTED). KS KITCHEN SINK 1/2" 1/2"2"2"KOHLER PULL-DOWN SINGLE-HANDLE KITCHEN FAUCET CRUE K-22972. 1.5 GPM @ 60PSI.EQUIVALENT FIXTURE ACCEPTABLE. SINK TO BE PROVIDED BY OTHERS. FD FLOOR DRAIN -- --2"2"ZURN Z415B W/SEDIMENT BUCKET. TRAP PRIMER CONNECTION WHERE REQUIRED BY CODE.EQUIVALENT FIXTURE ACCEPTABLE. WCO WALL CLEANOUT -- ---- LINE SIZE ZURN Z1441 WALL CLEANOUT W/SMOOTH ACCESS COVER EQUIVALENT FIXTURE ACCPETABLE. WH WATER HEATER 3/4" 3/4" ----RHEEM LIGHT DUTY ELECTRIC TANK TYPE WATER HEATER, MODEL NUMBER: ELD30-TB; 30 GALLONSCAPACITY; 6 KW INPUT. EXPANSION TANK (ZURN MODEL XT-8, 2.1 GAL. INSTALLED WITH WATERHEATER. EQUIVALENT FIXTURE ACCEPTABLE. HD HUB DRAIN -- --2"2"ZURN Z1870 HUB DRAIN, 3" DIA. INLET, 2" DIA. OUTLET. EQUIVALENT FIXTURE ACCEPTABLE. 17. SEE ARCHITECTURAL DRAWINGS FOR HANDICAP FIXTURE LOCATIONS AND MOUNTING HEIGHTS. INSULATE ALL EXPOSED HOT WATER AND DRAIN PIPING BELOW HANDICAP LAVATORIES AND SINKS WITH INSULATING TAPE AND OFFSET P-TRAP AGAINST WALL. ALL FLUSH VALVES FOR HANDICAP SHALL BE LOCATED ON HANDICAPWHEELCHAIR ACCESS SIDE OF STALL. 18. ALL WASTE, SOIL AND VENT PIPING SHALL SLOPE AT 2% UNLESS OTHERWISEINDICATED. 19. ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS OR OTHER EQUIPMENTSHOWN IN WALLS OR ABOVE NON-ACCESSIBLE CEILINGS SHALL BE INSTALLEDBEHIND AN ACCESS PANEL. 20. PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BASE BID. HE SHALL FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS AND FUTURE WORK TO BE DONE. HE SHALL INCLUDE ALL HIS SITE INFORMATION AND CONDITIONS WITHIN HIS BASE BID. HE SHALL BE RESPONSIBLE FOR COMPLETE AND FULLY FUNCTIONINGPLUMBING SYSTEMS. 21. PLUMBING CONTRACTOR SHALL COORDINATE COMPLETE PLUMBING INSTALLATIONAND REQUIREMENTS PRIOR TO BASE BID WITH ALL LOCAL DISTRICTS ANDGOVERNING AUTHORITIES. INCLUDE ALL FINDINGS WITHIN THE BASE BID. 22. PROVIDE RECIRCULATION PUMP FOR HOT WATER WHEN THE HOT WATER PIPE IS OVER 50'. 23. PROVIDE TRAP SEAL PRIMER FOR FLOOR DRAIN SUBJECT TO INFREQUENT USE. 24. ALL PLUMBING, AND GAS LINES SHALL BE CONCEALED WITHIN THE BUILDING STRUCTURE TO AS GREAT EXTENT AS POSSIBLE. ALL EXPOSED CONDUITS,PLUMBING, ETC. SHALL BE INSTALLED AT LEAST 6" OFF FLOOR AND 3/4" FROM WALLSUSING STANDOFF BRACKETS. 25. PLUMBING OR PIPING CANNOT BE INSTALLED ACROSS ANY AISLE WAY, TRAFFICAREA OR DOOR OPENING. 26. MULTIPLE RUNS OR CLUSTERS OF PIPELINES SHALL BE FURRED IN OR ENCASED INAN APPROVED SEALED ENCLOSURE. 27. APPROVED BACKFLOW PREVENTION DEVICES SHALL BE PROPERLY INSTALLED UPSTREAM OF ANY POTENTIAL HAZARD BETWEEN THE POTABLE WATER SUPPLY AND A SOURCE OF CONTAMINATION. HOSES SHALL NOT BE ATTACHED TO A FAUCETOR HOSE BIBB UNLESS AN APPROVED BACKFLOW PREVENTER IS PROVIDED. 28. ALL SANITARY SYSTEM MATERIALS SHALL BE LISTED BY AN APPROVED LISTINGAGENCY. 29. EACH VENT SHALL RISE VERTICALLY TO A POINT NOT LESS THAN SIX (6) INCHESABOVE THE FLOOD-LEVEL RIM OF THE FIXTURE SERVED BEFORE OFFSETTINGHORIZONTALLY OR BEFORE BEING CONNECTED TO ANY OTHER VENT. 30. EACH VENT SHALL TERMINATE NOT LESS THAN 10 FEET FROM, OR AT LEAST 3 FEET FROM, OR NOT LESS THAN 3 FEET ABOVE, ANY OPENABLE WINDOW, DOOR, OPENING, AIR INTAKE, OR VENT SHAFT, OR NOT LESS THAN 3 FEET IN EVERY DIRECTION FROM ANY LOT LINE. 31. FIELD VERIFY ALL EXISTING PLUMBING CONDITIONS AND EXISTING/NEW HVACPLUMBING CONNECTIONS PRIOR TO BIDDING AND START OF WORK. 32. IN THE EVENT THAT THE PLANS DO NOT REPRESENT FIELD CONDITIONS, CONTACTTHE OWNER, ARCHITECT, OR DESIGNATED ENGINEER DESIGNER PRIOR TO START OFANY WORK. 33. CAP ALL DOMESTIC WATER PIPING THAT IS SERVING A PLUMBING FIXTURE THAT IS BEING DEMOLISHED. 34. NEW OR REPAIRED POTABLE WATER SYSTEMS SHALL BE DISINFECTED PRIOR TO USE. CONTRACTOR SHALL PROVIDE A SIGNED WRITTEN DECLARATION TO THE INSPECTOR AT TIME OF INSPECTION THAT POTABLE WATER SYSTEM HAS BEENDISINFECTED. 35. EXISTING BUILDING SEWERS AND BUILDING DRAINS MAY BE USED IF SUCH SEWERSHAVE BEEN PROPERLY MAINTAINED AND FOUND UPON EXAMINATION AND TESTPERFORMED BY THE OWNER OR OWNER'S DESIGNATED AGENT THAT THEY ARE INWORKING CONDITION AND FREE FROM ANY DEFECT. 36. CLEANOUTS SHALL BE INSTALLED AS PER SEC. 707.0 & 719.0 OF THE PLUMBING CODE. SHEET INDEX P000 P001 P002 P100 P200 TP00 ·EXISTING COMMERCIAL TENANT IMPROVEMENT. ·PROVIDE NEW PLUMBING FIXTURES/CONNECTIONS THROUGHOUT THE SPACE. ·NEW WATER HEATER TO BE INSTALLED. PLUMBING NOTES & SCHEDULES PLUMBING DETAILS PLUMBING SPECIFICATION SHEETS WASTE & VENT PLAN TITLE 24 SCOPE OF WORK WATER PLAN NONRESIDENTIAL NOTES LAVATORIES IN RESTROOMS OF PUBLIC FACILITIES SHALL BE EQUIPPED WITH OUTLETDEVICES THAT LIMIT THE FLOW OF HOT WATER TO A MAXIMUM OF 0.5 GPM OR WITHSELF-CLOSING FAUCETS THAT LIMIT DELIVERY TO A MAXIMUM OF 0.2 GALLONS OF HOTWATER FOR RECIRCULATING SYSTEMS, AND SHALL BE EQUIPPED WITH DEVICES THAT LIMIT THE OUTLET TEMPERATURE TO A MAXIMUM OF 110 °F. CA GREEN BUILDING NOTES 5.303.2 PLUMBING FIXTURES SHALL MEET THE MAXIMUM FLOW RATE VALUES SHOWN IN TABLES A5.303.2.2. 5.303.3 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. PLUMBING FIXTURES(WATER CLOSETS AND URINALS) AND FITTINGS (FAUCETS AND SHOWERHEADS) SHALLCOMPLY WITH THE FOLLOWING: 5.303.3.1 WATER CLOSETS. THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETSSHALL NOT EXCEED 1.28 GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE PERFORMANCE CRITERIA OF THE U.S. EPA WATER SENSE SPECIFICATION FOR TANK-TYPE TOILETS. NOTE: THE EFFECTIVE FLUSH VOLUME OF DUAL FLUSH TOILETS IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO REDUCED FLUSHES AND ONEFULL FLUSH. 5.303.3.2 URINALS. THE EFFECTIVE FLUSH VOLUME OF WALL-MOUNTED URINALSSHALL NOT EXCEED 0.125 GALLONS PER FLUSH.THE EFFECTIVE FLUSH VOLUME OFFLOOR-MOUNTED URINALS SHALL NOT EXCEED 0.5 GALLONS PER FLUSH. 5.303.3.4.1 NONRESIDENTIAL LAVATORY FAUCETS. LAVATORY FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 0.5 GALLONS PER MINUTE AT 60 PSI. 5.303.4.2 KITCHEN FAUCETS. KITCHEN FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 1.8 GALLONS PER MINUTE AT 60 PSI. KITCHEN FAUCETS MAY TEMPORARILY INCREASE THE FLOW ABOVE THE MAXIMUM RATE, BUT NOT TOEXCEED 2.2 GALLONS PER MINUTE AT60 PSI, AND MUST DEFAULT TO A MAXIMUMFLOW RATE OF 1.8 GALLONS PER MINUTE AT 60 PSI. 5.303.6 PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITHTHE 2022 CALIFORNIA PLUMBING CODE, AND SHALL MEET THE APPLICABLE STANDARDSREFERENCED IN TABLE 1401.1 OF THE 2022 CALIFORNIA PLUMBING CODE AND INCHAPTER 6 OF THIS CODE. PIPE INSULATION THICKNESS FLUIDTEMP.RANGE(°F) CONDUCTIVITYRANGE(BTU-"/HR PERSQFT/°F) INSULATIONMEANRATINGTEMP. (°F) NOMINAL PIPE DIAMETER (") INSULATION THICKNESS REQUIRED (") <1 1 TO<1.5 1.5 TO<4 4 TO <8 8 ANDLARGER 251-350 350< 201-250 141-200 105-140 40-60 <40 SPACE COOLING SYSTEMS (CHILLED WATER, REFRIGERANT AND BRINE) SPACE HEATING, HOT WATER SYSTEMS AND SERVICE WATER HEATING SYSTEMS 0.32-0.34 0.29-0.31 0.27-0.30 0.25-0.29 0.22-0.28 0.21-0.27 0.20-0.26 250 200 150 125 100 75 50 4.5 3.0 2.5 1.5 1.0 1.0 5.0 4.0 2.5 1.5 1.5 1.5 5.0 4.5 2.5 2.0 1.5 1.5 5.0 4.5 3.0 2.0 1.5 1.5 5.0 4.5 3.0 2.0 1.5 1.5 EXCEPTIONS: (1) FACTORY-INSTALLED PIPING WITHIN SPACE CONDITIONING EQUIPMENT;(2) PIPING THAT CONVEYS FLUIDS THAT HAVE A DESIGN OPERATING TEMPERATURERANGE BETWEEN 60 DEGREES AND 105 DEGREES FAHRENHEIT;(3) WHERE THE HEAT GAIN OR HEAT LOSS TO OR FROM PIPING WITHOUT INSULATIONWILL NOT INCREASE BUILDING SOURCE ENERGY USE;(4) PIPING THAT PENETRATES FRAMING MEMBERS SHALL NOT BE REQUIRED TO HAVEPIPE INSULATION FOR THE DISTANCE OF THE FRAMING PENETRATION. METAL PIPING THAT PENETRATES METAL FRAMING SHALL USE GROMMETS, PLUGS, WRAPPING OR OTHER INSULATING MATERIAL TO ASSURE THAT NO CONTACT IS MADE WITH THE METAL FRAMING. SPACE-CONDITIONING AND SERVICE WATER-HEATING SYSTEM SHALL BEINSULATED IN ACCORDANCE WITH THE FOLLOWING TABLE: NONRES 0.5 RES 0.75 1.01.0 1.0 PIPE INSULATION PLUMBING SPECIFICATION 1. CLEANOUTSPROVIDE CLEANOUTS WITH BRASS SCREW PLUG AT ALL CHANGES OF DIRECTIONTO PERMIT ROUTING OF ALL SEWERS. ALL CLEAN OUTS SHALL BE INSTALLEDWHERE READILY ACCESSIBLE. THE CONTRACTOR SHALL COORDINATE ALL CLEANOUT LOCATIONS OF EQUIPMENT, CABINETS, ETC., WITH THE ARCHITECT PRIORTO ANY INSTALLATION. 2. VALVES EVERY PLUMBING FIXTURE SHALL BE INDEPENDENTLY VALVED. 3. TESTING ALL SEWERS AND WATER PIPING SHALL BE PROPERLY TESTED TO THESATISFACTION OF THE ARCHITECT AND THE LOCAL BUILDING INSPECTOR. 4. EXCAVATION AND BACK FILLINGTRENCHES SHALL BE BACK FILLED AND SETTLED BY PUDDLING. NO PIPE SHALLBE LESS THAN 12" BELOW FINISH GRADE. 5. PIPING SUPPORTSALL PIPING TO BE SUPPORTED WITH HANGERS AND BRACKETS WHICH PROVIDE ISOLATION FROM FRAMING. CONTACT BETWEEN PIPE AND SUPPORT TO BE LINED WITH PLASTIC OR FELT. NOTE:1. ABS AND PVC INSTALLATIONS ARE LIMITED TO NOT MORE THAN TWO STORIES OFAREAS OF RESIDENTIAL ACCOMMODATION.2. ABS/PVC VENT TERMINATIONS UP THROUGH THE ROOF EXPOSED TO SUNLIGHT AREREQUIRED TO BE PROTECTED BY WATER BASED SYNTHETIC LATEX PAINTS. INSIDE NATURAL SANITARY WASTESANITARY GAS VENT INSIDE OUTSIDE EXPOSED CONCEALED OUTSIDE COP P E R - T Y P E " M " WATERDOMESTIC SERVICE: PIP E M A T E R I A L : OUTSIDE INSIDE COP P E R - T Y P E " L " COP P E R - T Y P E " K " SCH E D . 4 0 P V C , D W V REMARKS: INDIRECTWASTE INSIDE INSIDE* PIPE MATERIAL SCHEDULE *USE COPPERTYPE "M" FORCONDENSATE SCH E D . 4 0 BLA C K S T E E L CAS T I R O N S O I L W / H . G . OR " I D E A L " F I T T I N G S SCH E D U L E 4 0 GAL V A N I Z E D S T E E L SCH E D . 4 0 A B S , D M V GSOV W/ AUTOMATIC GAS SHUT-OFF VALVE WITH FLR NTS IE CFH DN FF POC (N) FCO/COTG WCO SOV CUBIC FEET PER HOUR FINISHED FLOOR ELEVATION FLOOR NOT TO SCALE INVERT ELEVATION DOWN POINT OF CONNECTION NEW FLOOR CLEANOUT/CLEANOUT TO GRADE WALL CLEANOUT COLD WATER SHUT-OFF VALVE ABBR. PLUMBING LEGEND HW G CD T&P V GW S OR W CW SYMBOL DOMESTIC COLD WATER SOIL OR WASTE BELOW FLOOR LOW PRESSURE GAS DOMESTIC HOT WATER PRIMARY CONDENSATE DRAIN TEMPERATURE & PRESSURE VENT DESCRIPTION HWR DOMESTIC HOT WATER RETURN C.V.CHECK VALVE PRV PRESSURE REDUCING VALVE BALANCING VALVE SOC SHUT-OFF COCK (GAS) TMV TEMPERATURE MIXING VALVE VTR VENT TO ROOF BLV CP RECIRCULATION PUMP CW COLD WATER STUB-IN HW HOT WATER STUB-IN XSS XGW EXISTING WASTE/SANITARY SEWER EXISTING GREASE WASTE XCW FW EXISTING COLD WATER FILTERED WATER (E)EXISTING (R)RELOCATED, EXISTING XG EXISTING GAS XHW EXISTING HOT WATER GREASE WASTE BELOW FLOOR GSOV GAS SHUT-OFF VALVE CWV COMBINATION WASTE & VENT BELOW HOSE BIBBHB DCO DOUBLE CLEANOUT BACKFLOW PREVENTERBFP RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 3/4/2024 6:19:37 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: PL A N C H E C K R E V . 0 1 / 2 9 / 2 0 2 4 P000 M 37036 Exp. 9-30-24 U N G S UN K AHCG N L.C.H.D. N.T.S. PLUMBING NOTES & SCHEDULES FILL TANK WITH AIRPRESSURE TO MATCHWATER PRESSURE,THEN OPEN VALVE WELDED STEEL EXPANSION TANK WITH POLYPROPYLENE LINING, FDA APPROVED FOR DOMESTIC WATER SERVICE PIPE UNION: DIELECTRIC IF REQUIRED FOR DISSIMILAR METALS BUTYL DIAPHRAGM FROM CW SUPPLY TOHEATER, NOINTERVENING VALVES PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. MAKE PIPE SAME SIZE AS TANK FITTING. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATIONPROCEDURE. VERIFY PROPER OPERATION WHEN INSTALLED. EXPANSION TANK DETAIL 5 SCALE N.T.S SEISMIC STRAPPING FORBRACING IN SEISMIC AREAS PROVIDE WCO WHERE SHOWN ON PLAN, AND ONSANITARY WASTE BRANCHES NOT SERVED WITH AFLOOR CLEANOUT: LOCATED ABOVE FIXTURE FLOORRIM WITHIN 4'-0" OF FLOOR. CONSULT LOCAL CODESFOR OTHER WCO REQUIREMENTS. RISER LENGTH AS REQUIRED LONG SWEEP AT END OF LINE OR COMBINATION WYEAND EIGHTH BENDIN RUN OF LINE. INSTALL ESCUTCHEONPLATE AT CLEANOUT TEE. PROVIDE SCREWED COUNTER-SINK BRONZEPLUG FOR CLEANOUT TEEWITH TAPPED THREAD &TEE JOINT COMPOUND CONCRETE FLR. WASTE ORVENT TOABOVE PLUMBING WALL ORCOLUMN REFER TOFLOOR PLANS PROVIDEWATERPROOFING 2 SCALE N.T.S NOTE: DIRECTION OF FLOW WALL CLEANOUT DETAIL PIPE INSULATION INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS PIPE INSULATION PROTECTION SHIELD. USE 16 GAUGESHEET STEEL, 2 PIPE DIAMETERS LONG, 120DEGREES SUPPORT, OR GRINNEL FIGURE 167. HANGER ROD PROVIDE GALV. STEEL SHIELD FOR ALLINSULATED PIPE.VERIFY INSULATION THICKNESSWHEN SIZING HANGERS AND SHIELDS. ADJUSTABLE BAND HANGER FOR PIPE 3-1/2" AND SMALLERAND CAST IRON PIPE 2" ANDSMALLER HANG PIPE LARGER THAN 4"FROM TOP OF JOISTS ONLY ATPANEL POINT SIDE BEAM CONNECTOR ATTACHED TO TOP CHORD OF WOOD TRUSS PROVIDE COPPER COATEDHANGERS WHEREHANGERS CONTACT BARECOPPER PIPE PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN HERE.DO NOT INSTALL HANGER INSIDE INSULATION OR OTHERWISE PENETRATEVAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER EXCEPT IN CHASES.SLOPE ALL WATER PIPING SLIGHTLY TOWARD DRAINABLE LOCATIONS. HANGERSPACING FOR PIPE SIZES: AS INDICATED IN TABLE. CAST IRON: 10' AND WITHIN 1'-0" OF ALL JOINTS. ROD SIZES FOR PIPE SIZE: 1/2" TO 4" = 3/8", 5" TO 8" = 1/2", 10" TO 12" = 5/8". LOCATE HANGERS WITHIN 1'-0" OF VALVES AND FITTINGS. PROVIDE SUPPLEMENTAL STEEL STRUTS BETWEEN JOISTS IF REQUIRED.LOCATE HANGERS WITHIN 1'-0" OF EQUIPMENT CONNECTIONS. ANCHOR WATERPIPE AGAINST SWAYING DUE TO CHANGES IN WATER VELOCITY. CHAINS ANDPERFORATED STRAP IRON AND STEEL ARE NOT ACCEPTABLE. DO NOTSUSPEND PIPE FROM JOIST BRACING MEMBERS. REFER TO CODES ANDSPECIFICATIONS FOR FURTHER INFORMATION. PROVIDE SEISMIC BRACING AS REQUIRED BY LOCAL AUTHORITIES. PROVIDE FIBERGLASS INSULATION WITH ALL-SERVICE JACKET WITH VAPOR BARRIER ON ALL SIZES OF HOT AND COLD WATER AND CONDENSATE PIPING. GAS PIPING SHALL BE KEPT A MIN. OF 6"ABOVE GRADE OR STRUCTURE. GAS PIPE SUPPORT STEEL PIPE, NOMINAL SIZE OFPIPE (INCHES) SPACING OF SUPPORTS(FEET) NOMINAL SIZE OF TUBING SMOOTH-WALL(INCHES O.D.) SPACING OFSUPPORTS(FEET) 1/2 6 1/2 4 3/4 OR 1 8 5/8 OR 3/4 6 1-1/4 OR LARGER (HORIZONTAL)10 7/8 OR 1 (HORIZONTAL)8 1-1/4 OR LARGER (VERTICAL EVERY FLOOR LEVEL 1 OR LARGER (VERTICAL) EVERY FLOOR LEVEL 1 SCALE N.T.S 6'1-1/2" 10'4"10'10'10'2-1/2"3" 2" ALL-THREAD ROD CO P P E R P I P E HA N G E R S P A C I N G 6'1/2"1/2"6'3/4" 6' 6' 1-1/4" 1" PI P E S I Z E WOOD STRUCTURE CL LC STEEL STRUCTURE SECTION PIPE HANGER DETAIL (BELOW ROOF) WATER PIPE SUPPORT: ELMDOR/STONEMAN, MODEL#1100-4 SEALANT SHALL BEAPPLIED AROUND PIPE OPENINGTHRU COUNTER FLASHINGSLEEVE FOR WATER TIGHT SEAL BUILT-UP ROOFING APPLY PERMASEAL WATER PROOFING COMPOUND AROUND PIPE, COUNTER FLASHING SLEEVE &FLASHING FOR WATERTIGHT SEAL. SEAMLESS LEAD FLASHING OVER STEEL REINFORCED BOOT INSTALL (3)VANDAL- PROOFSET SCREWS 8" MIN.BOOT HEIGHT5" MIN. 12" MIN. PIPE THRU ROOF 3 SCALE N.T.S 2" MIN. PIPING THRU ROOF DETAIL SCALE 4N.T.SELECTRIC WATER HEATER DETAIL CW IN HW OUT THERMAL EXPANSION TANK VACUUM RELIEF VALVE DIELECTRIC UNION (TYP) ASME T&P RELIEF VALVE.TERMINATE DISCHARGE FULLSIZE OF VALVE CONNECTIONTO HUB DRAIN. CHECK VALVE 1/4 TURN BALL VALVE TANK TYPE WATER HEATER FOR SEISMIC APPLICATIONS:PROVIDE 1/8" THICK X 2"W. 22GA. STEEL STRAP SECUREDTO 3/8" THICK X 6"W. STEELPLATE ANCHORED TOMINIMUM (4) STUDS W/ 1/2"Ø ANCHOR BOLTS OR LAG SCREWS (NUTS AND BOLTS FOR STEEL STUDS) HW OUT WATER HEATER SHALL BE STRAPPED TO THE BUILDINGAT THE 1/3-POINT TOP ANDBOTTOM WATER HEATER STAND (4-INCH HIGH, COVED PLATFORM/CURB OR AT LEAST 6-INCH HIGH,SMOOTH, EASILYCLEANABLE LEGS.) TRAP PRIMER DETAIL CW LINE ABV. CLG. 1/2" CW TRAP PRIMERLINES IN WALL (TYPE 'L' COPPER) TRAP WALL FINISH FLOOR FLOOR DRAIN 6 SCALE N.T.S RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 3/4/2024 6:19:37 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: PL A N C H E C K R E V . 0 1 / 2 9 / 2 0 2 4 P001 M 37036 Exp. 9-30-24 U N G S UN K AHCG N L.C.H.D. PLUMBING DETAILS N.T.S. RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 3/4/2024 6:19:45 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: PL A N C H E C K R E V . 0 1 / 2 9 / 2 0 2 4 P002 M 37036 Exp. 9-30-24 U N G S UN K AHCG N L.C.H.D. PLUMBING SPECIFICATION SHEETS N.T.S. UTILITY ROOM PRODUCT STORAGE LOUNGE ROOM RECEPTION MANUFACTURE STOCK PRODUCT BREAK ROOM DELIVER OFFICE COMMON HALLWAY RECEPTION A.R.R.1 A.R.R.2 OFFICE MANUFACTURE AREA GENERAL NOTES: 1. IF DRAWINGS ARE INCORRECT FROM THE ACTUAL SITE CONDITION,CONTRACTOR SHALL NOTIFY ENGINEER(S) AND PROVIDE INFORMATION REFLECTING ACTUAL CONDITIONS. 2. ALL PLUMBING FIXTURES AND CONNECTIONS ARE NEW UNLESS NOTED AS EXISTING. 3. COORDINATE FLOOR SINK AND DRAIN LOCATIONS, IF ANY, WITH ARCHITECTURAL AND FOOD SERVICE PLAN PRIOR TO ROUGH-IN. 4. ALL UNDERGROUND WASTE PIPING SHALL BE SLOPED AT A 2% GRADE UNLESS OTHERWISE NOTED. 5. PROVIDE WALL CLEAN OUTS TO ALL SINK AND URINAL FIXTURES. KEYED PLAN NOTES:# WASTE & VENT PLAN 1. P.O.C. TO EXISTING 4" SANITARY WASTE WITH NEW PIPING. FIELD VERIFYALL EXISTING CONDITIONS, SIZE, AND LOCATION PRIOR TO START OF THISWORK. 2. INSTALL NEW 3" VENT THRU ROOF. FIELD VERIFY LOCATION PRIOR TOSTART OF THIS WORK. 3. WATER HEATER T&P VALVE DRAIN TO HUB DRAIN. WC WC LAVLAV KS 4"W 2"W 2"W 2"W 4"W 4"W; MINIMUM 2% SLOPE 4"W; MINIMUM 2% SLOPE 2 2 2"V 2"V 2"V 1 WH FD FD 2"V 2"W2"W 2"V 2"V WCO 3 WCO2"W HD WCO 1 4"W RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 3/4/2024 6:19:40 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: PL A N C H E C K R E V . 0 1 / 2 9 / 2 0 2 4 P100 1/4" = 1'-0" M 37036 Exp. 9-30-24 U N G S UN K AHCG N L.C.H.D. WASTE & VENT PLAN 1 UTILITY ROOM PRODUCT STORAGE LOUNGE ROOM RECEPTION MANUFACTURE STOCK PRODUCT BREAK ROOM DELIVER OFFICE COMMON HALLWAY RECEPTION A.R.R.1 A.R.R.2 OFFICE MANUFACTURE AREA GENERAL NOTES: KEYED PLAN NOTES:# 1. P.O.C. TO EXISTING 1" CW LINE WITH NEW PIPING. FIELD VERIFY ALL EXISTING CONDITIONS SIZE AND LOCATIONS PRIOR TO START OF THIS WORK. 2. PROVIDE 1/2" TRAP PRIMER FOR FLOOR DRAIN. 3. INSTALL WATER HEATER WITH NEW PIPING. FIELD VERIFY LOCATION ANDSIZE BEFORE START OF WORK. SEE PLUMBING SCHEDULE AND PLUMBINGDETAILS ON P000 AND P001, RESPECTIVELY. 1. IF DRAWINGS ARE INCORRECT FROM THE ACTUAL SITE CONDITION, CONTRACTOR SHALL NOTIFY ENGINEER(S) AND PROVIDE INFORMATION REFLECTING ACTUAL CONDITIONS. 2. ALL PLUMBING FIXTURES AND CONNECTIONS ARE NEW UNLESS NOTED AS EXISTING. WATER PLAN WC WC LAVLAV KS WH (E)WATER METER WM TYP. 3/4"CWFOR WC (2.5 FU) TYP. 1/2"HW/CW FOR LAV (1 FU) 1/2"HW/CW FOR KS (1.5 FU)3/4"CW (3.5 FU) 3/4"CW (3.5 FU) 3/4"CW(7 FU) 3/4"CW (TOT. 8.5 FU) (E)1"CW (TOT. 8.5 FU) FD FD 1/2"HW(2.5 FU) 3/4"HW(TOT. 3.5 FU) 3/4"HW/CWFOR WH 1 2 2 3 RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 3/4/2024 6:19:44 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: PL A N C H E C K R E V . 0 1 / 2 9 / 2 0 2 4 P200 1/4" = 1'-0" M 37036 Exp. 9-30-24 U N G S UN K AHCG N L.C.H.D. WATER PLAN 1 TITLE 24 RE V I S I O N SHEET TITLE: DATE: SCALE: I- K R U S H E R W A R E H O U S E O F F I C E A R C A D I A 12/12/2023 PLOT DATE: 3/4/2024 6:19:42 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 5 3 3 - 4 1 1 7 | d k a n g @ c d i e n g . c o m 11 8 1 8 C L A R K S T , AR C A D I A , C A 9 1 0 0 6 DRAWN: CHECKED: PL A N C H E C K R E V . 0 1 / 2 9 / 2 0 2 4 TP00 M 37036 Exp. 9-30-24 U N G S UN K AHCG N L.C.H.D. TITLE 24 N.T.S. 9890 RESEARCH DR. SUITE 100 IRVINE, CA 92618 949-533-4117 9890 RESEARCH DR. SUITE 100 IRVINE, CA 92618 949-533-4117 M37036 3/4/2024 3/4/2024 11818 Clark St., Arcadia, CA 91006 11818 Clark St., Arcadia, CA 91006 11818 Clark St., Arcadia, CA 91006 11818 Clark St., Arcadia, CA 91006 11818 Clark St., Arcadia, CA 91006 11818 Clark St., Arcadia, CA 91006 11818 Clark St., Arcadia, CA 91006