Loading...
HomeMy WebLinkAbout57 E Foothill Blvd - 2024 - TILEGEND PROJECT SUMMARY Water ClosetWC WD Wood TypicalTYP Top Of CurbTC TW Top Of Wall Top of Paraphet Top Of GradeTG TOP RD Roof Drain SCH Schedule Specification Similar SheetSHT SIM SPEC RM Room RequiredREQ'D STRUCT Structural HeightHT Property LinePL MTL MECH Mechanical Metal Not To Scale Natural GradeNG NTS On CenterOC LWC Light Weight Concrete Air ConditioningHVAC WIC Walk In Closet GRID LINES DETAIL REFERENCE WINDOW DOOR X#.# X SECTION CUT DETAIL REFERENCE REVISION NUMBER SMOKE DETECTOR X-#NOTE REFERENCE FAN OUTLET W/GROUND-FAULT CIRCUIT-INTERRUPTER DUPLEX RECEPTACLE OUTLET "HALF-HOT" OUTLET SPLIT-WIRED RECEPTACLE THREE-WAY SWITCH SINGLE-POLE SWITCH CEILING MOUNTED JUNCTION BOX COMPUTER DATA OUTLET TELEVISION / CABLE OUTLET INCANDESCENT LIGHTING CEILING MOUNTED INCANDESCENT LIGHTING WALL MOUNTED FLUORESCENT LIGHTING CEILING RECESSED TELEPHONE OUTLET AluminumAL BLDG BALC Balcony Building CONC Concrete Double ContinuousCONT DBL CLR CLO CLG CL Center Line Ceiling Closet Clear Down Spout DownDN DS DIM Dimension FL Floor Face of Wall (Finish) Face of StudFOS FOW GEN GYP Gypsum Board General Fire Extinguisher Foot or FeetFT FX FG FF FD EXT Exterior Floor Drain Finish Floor Finish Grade Fire Hose Cabinet Fire HydrantFH FHC EXIST EQ Equal Existing Elevation Electrical DrawingDWG ELEC ELEV LEGAL DESCRIPTION X-0 00 # X X X X X-0 00 X-0 00 X ARCHITECTURE A0.0 TITLE SHEET A0.1 GENERAL NOTES A0.4a GREEN BUILDING CODE - NON-RESIDENTIAL MANDATORY MEASURES A0.4b GREEN BUILDING CODE - NON-RESIDENTIAL MANDATORY MEASURES A0.4c GREEN BUILDING CODE - NON-RESIDENTIAL MANDATORY MEASURES A0.5a CBC 11B DIV 1 & DIV 2 APPLICATION A0.5b CBC 11B DIV 2 & DIV 3 BUILDING BLOCKS A0.5c CBC 11B DIV 4 ACCESSIBLE ROUTES A0.5e CBC 11B DIV 5 SITE AND BUILDING ELEMENTS A0.5f CBC 11B DIV 6 PLUMBING ELEMENTS & FACILILTIES A0.5g CBC 11B DIV 7 - 8 - 9 A1.0 SITE PLAN A2.0 EXISTING / DEMOLITION PLANS A2.1 FLOOR PLAN - FIRST FLOOR A2.2 FLOOR PLAN - MEZZANINE (EXISTING NO CHANGE) A2.3 ROOF PLAN A2.4 FINISH PLAN: FIRST FLOOR & MEZZANINE FLOOR A3.1 REFLECTED CEILING PLAN: FIRST FLOOR A3.2 REFLECTED CEILING PLAN: MEZZANINE FLOOR A4.1 BUILDING ELEVATIONS A4.2 BUILINDG SECTIONS A4.3 BUILINDG SECTIONS A5.1 RESTROOM ENLARGED PLAN / INTERIOR ELEVATIONS A6.0 DOOR / WINDOW SCHEDULES A7.1 ARCHITECTURAL DETAILS A7.2 ARCHITECTURAL DETAILS SHEET INDEX BUILDING CODE APN:5771-020-014 THE PROPERTY IS LOCATED ON THE NORTH SIDE OF EAST FOOTHILL BOULEVARD, BETWEEN OAKWOOD DRIVE TO THE WEST AND HIGHLAND OAKS DRIVE TO THE EAST. FILED IN TRACT # 4129 EX OF ALLEY LOT 11 BLK 2, IN THE CITY OF ARCADIA, COUNTY OF LOS ANGELES, STATE OF CALIFORNIA. Square FeetSF VICINITY MAP TV S3 S SD J GFI xx xx 57 FOOTHILL BLVD. ARCADIA, CA 91006 PROJECT DESCRIPTION ADDRESS OWNER NAME OWNER ADDRESS OWNER PHONE # ZONING CONSTRUCTION TYPE OCCUPANCY NUMBER OF STORIES FIRE SPRINKLERS LOT SIZE (SQFT) SCOPE AREA LOT COVERAGE PARKING 57 E FOOTHILL BLVD., ARCADIA, CA 91006 VENTURE ONE CAPITAL, LLC 57 E FOOTHILL BLVD. ARCAIDA, CA 91006 323-384-6363 C-G V-B B 1 + MEZZANINE NONE SPRINKLED (EXISTING) 5,832 SF 3,500 SF EXISTING NO CHANGE EXISTING NO CHANGE APPLICABLE CODES: 2022 CALIFORNIA BUILDING CODE (2021 INTERNATIONAL BUILDING CODE), 2022 CALIFORNIA MECHANICAL CODE (2021 INTERNATIONAL MECHANICAL CODE), 2022 CALIFORNIA PLUMBING CODE (2021 INTERNATIONAL PLUMBING CODE), 2022 CALIFORNIA FIRE CODE (2021 INTERNATIONAL FIRE CODE), 2022 CALIFORNIA ELECTRICAL CODE (2020 NATIONAL ELECTRICAL CODE) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE, 2022 CALIFORNIA ENERGY CODE. TAG DESIGN WORKS JOHNNY LU, AIA, LEED AP, C30396 411 E. HUNTINGTON DR., SUITE 308 ARCADIA, CA 91006 T: 626.446.5300 ARCHITECT GENERAL NOTES CONSTRUCTION NOTES 1.CONTRACTOR TO PROVIDE PAINT/COLOR SAMPLE FOR ARCHITECT/OWNER'S APPROVAL PRIOR PAINTING. 2.CONTRACTOR TO PROVIDE STAIR SHOP DRAWINGS FOR ARCHITECT/OWNER'S APPROVAL PRIOR INSTALLATION. 3.CONTRACTOR TO PROVIDE GUARDRAIL/HANDRAIL SHOP DRAWINGS FOR ARCHITECT/OWNER'S APPROVAL PRIOR INSTALLATION. 4.CONTRACTOR TO PROVIDE ROOFING SAMPLE FOR ARCHITECT/OWNER'S APPROVAL PRIOR INSTALLATION. 5.CONTRACTOR TO PROVIDE DOOR/WINDOW SHOP DRAWINGS FOR ARCHITECT/OWNER'S APPROVAL PRIOR INSTALLATION. 6.CONTRACTOR TO PROVIDE LIGHT SWITCH SAMPLE FOR ARCHITECT/OWNER'S APPROVAL PRIOR INSTALLATION. 7.CONTRACTOR TO PROVIDE TILE SAMPLE FOR ARCHITECT/OWNER'S APPROVAL PRIOR INSTALLATION. 8.CONTRACTOR TO PROVIDE CABINET SHOP DRAWINGS FOR ARCHITECT/OWNER'S APPROVAL PRIOR INSTALLATION. CONSULTANTS DETAIL ENLARGEMENT REFERENCE INTERIOR ELEVATION REFERENCE WPH ENGINEERING 411 E. HUNTINGTON DR., SUITE 313 ARCADIA, CA 91006 T: 626.446.5300 STRUCTURAL ENGINEER SITE INFORMATION ASSESSORS PARCEL NO:5771-020-014 SITE AREA:(E) 5,822 SF GENERAL PLAN DESIGNATION:C-G BUILDING FLOORS:(E) SINGLE-STORY JURISDICTION:LOS ANGELES COUTY ZONING NOTES DEFERRED SUBMITTAL A0.0 TITLE SHEET SUBMITTAL LOG 1. DEMOLISH EXISTING INTERIOR PARTITION WALLS, PLUMBING FIXTURES, MECHANICAL SYSTEM, AND EXTERIOR WINDOWS AND DOORS. 2. PROPOSED INTERIOR TENANT IMPROVEMENTS. 3. PROPOSED EXTERIOR BUILDING FACADE REMODEL. SITE AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 ELECTRICAL E-0.0 ELECTRICAL SYMBOLS & LEGENDS E-1.0 LIGHTING LAYOUT- FIRST FLOOR E-1.1 LIGHTING LAYOUT - SECOND FLOOR E-2.0 ELECTRICAL POWER LAYOUT - FIRST FLOOR E-2.1 ELECTRICAL POWERLAYOUT - SECOND FLOOR E-3.0 ELETRICAL ONE-LINE & SCHEDULE E-4.0 TITLE-24 MECHANICAL M-00 MECHANICAL LEAD SHEET M-01 MECHANICAL FLOOR PLAN M-02 MECHANICAL ENERGY COMPLIANCE M-03 MECHANICAL ENERGY MANDATORY MEASURES M-04 ENVELOPE ENERGY COMPLIANCE PLUMBING P-00 PLUMBING LEAD SHEET P-01 PLUMBING FLOOR PLANS P-02 PLUMBING ENERGY COMPLIANCE MWQ ENGINEERING Tustin, California 92782 T: 562.413.9495 MEP ENGINEERING STRUCTURAL S0.1 STRUCTURAL GENERAL NOTES S1.0 FOUNDATION PLAN S2.0 CEILING / MEZZ. FRAMING PLAN SD1 STRUCTURAL DETAILS SD2 STRUCTURAL DETAILS SECTIONS SD1 STRUCTURAL DETAILS SD2 STRUCTURAL DETAILS A. GENERAL REQUIREMENTS 1.THE ENTIRE WORK PROVIDED FOR HEREIN IS TO BE CONSTRUCTED AND FINISHED IN EVERY PART IN A GOOD AND SUBSTANTIAL MANNER IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, TO THE FULL INTENT OF THE SAME. ANY WORK REQUIRED BY LAW, BUT WHICH MAY NOT BE SPECIFICALLY MENTIONED BY LAW, SHALL BE DONE BY CONTRACTORS IN ACCORDANCE WITH THE LAWS OF THE CITY, COUNTY, DISTRICT, OR STATE UNDER WHICH JURISDICTION MAY COME AND COST SHALL BE BORNE BY CONTRACTORS. ANY SUCH WORK SHALL BE DONE IN CONFORMANCE WITH THE PLAN; BOTH AS TO MANNER AND APPEARANCE. ALL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT EDITION OF C.B.C., TITLE 24 AS REQUIRED BY GOVERNING AGENCIES. 2.THESE PLANS AND RELATED DOCUMENTS MUST BE AVAILABLE AT THE JOB SITE AT ALL TIMES & BE AVAILABLE DURING ANY INSPECTION ACTIVITY PER C.B.C. 3.SOLELY AS A CONVENIENCE TO THE OWNER, THE ARCHITECT MAY INCLUDE DOCUMENTS PREPARED BY CERTAIN CONSULTANTS (OR INCORPORATED THE RECOMMENDATIONS OF SAID CONSULTANTS IN DOCUMENTS PREPARED BY THE ARCHITECT) WITHIN THE SET OF DOCUMENTS ISSUED BY THE ARCHITECT BEING EXPRESSLY UNDERSTOOD THAT, BY SAID ISSUANCE, THE ARCHITECT ASSUMES NO LIABILITY FOR THE SERVICES OF SAID CONSULTANTS NOT UNDER CONTRACT TO THE ARCHITECT. 4.CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE, AND REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR INTERPRETATION AND/OR CORRECTIONS PRIOR TO INSTALLATION. COST OF CORRECTING WORK BASED ON MISINTERPRETATION BY CONTRACTOR OR UNREPORTED DIMENSIONAL DISCREPANCIES SHALL BE BORNE BY THE CONTRACTOR. 5.CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL HOURS: AND THAT THE CONTRACTOR SHALL DEFEND: INDEMNIFY AND HOLD THE OWNER & ARCHITECT HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. 6.WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE ON THE DRAWINGS. DO NOT SCALE THE DRAWINGS. 7.THE CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF DRAWINGS AT THE JOB SITE FOR USE IN MAKING "RECORD DRAWINGS." ANY REVISIONS SHALL BE NOTED THEREON AND SUBMITTED TO THE ARCHITECT AT THE COMPLETION OF THE JOB PER THE PROJECT MANUAL. PROVIDE A COPY FOR THE OWNER PER CONSTRUCTION DOCUMENTS. 8.THE OWNER AND/OR ARCHITECT RESERVE THE RIGHT TO HAVE TESTS MADE WHEN DEEMED NECESSARY. SHOULD THE ARCHITECT ORDER SPECIAL TESTING OR INSPECTION OF A QUESTIONABLE PART OF THE WORK WHICH REVEALS DEFECTS NOT IN CONFORMITY WITH THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL PAY THE COST OF SUCH SPECIAL TESTING OR INSPECTIONS INCLUDING THE ARCHITECTS EXTRA SERVICES MADE NECESSARY THEREBY. OTHERWISE THE OWNER SHALL BEAR SUCH COST. 9.THE ARCHITECT IS AUTHORIZED TO ORDER MINOR CHANGES DURING THE COURSE OF THE WORK WHICH WILL NOT INVOLVE EXTRA COST OR TIME AND WHICH ARE CONSISTENT WITH THE CONTRACT DOCUMENTS. 10.BEFORE THE BUILDING MAY BE OCCUPIED, INSTALLATION CERTIFICATES FOR MANUFACTURED DEVICES REGULATED BY THE APPLIANCE STANDARDS OR CHAPTER 2-53, SHALL BE POSTED ADJACENT TO THE BUILDING PERMIT(S) PLACED IN JOB SITE TRAILER. CERTIFICATES SHALL: A.IDENTIFY FEATURES REQUIRED TO VERIFY COMPLIANCE WITH THE APPLIANCE STANDARDS AND CHAPTER 2-53; B.IDENTIFY FEATURES REQUIRED TO VERIFY COMPLIANCE WITH THE APPLIANCE STANDARDS AND CHAPTER 2-53; 11.THE CONTRACTOR SHALL INFORM THE FIRE DEPT. OF THE REQUIRED FINAL INSPECTION AND SCHEDULE SUCH INSPECTION 24 HRS. IN ADVANCE. 12.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FILED VERIFY EXISTING SITE CONDITIONS AND DIMENSIONS PRIOR TO STARTING CONSTRUCTION. 13.IF ANY ERRORS, DISCREPANCIES OR OMISSIONS APPEAR ON THESE DRAWINGS. SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS, THE CONTRACTOR SHALL NOTIFY OWNER / ARCHITECT IMMEDIATELY. 14.NO MATERIAL SUBSTITUTION WILL BE ALLOWED UNLESS SUBMITTED IN WRITING TO OWNER / ARCHITECT FOR APPROVAL IN WRITING. NOTIFICATION MUST BE SUBMITTED WITHIN 10 WORKING DAYS OF CONTRACT AWARD. 15.THE CONTRACTOR IS REQUIRED TO PROVIDE A LIST OF ALL SUBCONTRACTORS TO BE USED AND SUBMIT LIST TO THE OWNER / ARCHITECT WITHIN 10 WORKING DAYS OF CONTACT AWARD. 16.THE CONTRACTOR IS RESPONSIBLE FOR CHECKING IN AND VERIFYING ALL SHIPMENTS OF OWNER SUPPLIED MATERIALS. THIS INCLUDES VERIFYING PACKING LISTS AGAINST ORDER FORMS AND BILLS OF LOADING. IF THIS IS NOT DONE, THE CONTRACTOR WILL BEAR THE COST OF ANY EXPEDITED FREIGHT CHARGES TO MEET THE CONSTRUCTION SCHEDULE. THE CONTRACTOR IS RESPONSIBLE FOR FILING DAMAGE REPORT AND MUST MAINTAIN PACKING MATERIALS FOR SHIPMENT OF DAMAGED ITEMS. 17.THE CONTRACTOR SHALL KEEP ALL HANDBOOKS AND PAPERWORK INCLUDING ALL PACKING SLIPS LADING IN A MARKED ENVELOPE. THIS ENVELOPE IS TO BE TURNED OVER TO OWNER. 18.THE CONTRACTOR SHALL DELIVER TO OWNER A COPY OF THE CERTIFICATE OF OCCUPANCY, LIEN WAIVER, WARRANTIES, GUARANTEES AND EQUIPMENT OPERATION MANUALS. 19.THESE DRAWINGS ARE NOT BE ALTERED IN ANY WAY WITHOUT WRITTEN AUTHORIZATION FROM OWNER OR FROM OWNER'S ARCHITECT. 20.THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING OF ALL EQUIPMENT, MERCHANDISE, CARPET, AND ETC. 21.ALL CONSTRUCTION TO CONFORM TO ALL APPLICABLE CODES AND ORDINANCES. 22.ALL DIMENSIONS ARE TO FINISH FACE OR STUDS, UNLESS OTHERWISE NOTED . 23.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS WITH STRUCTURE AND SHELL BUILDING ELEMENTS. CONTRACTOR IMMEDIATELY NOTIFY OWNER OF ANY SIGNIFICANT DISCREPANCIES BETWEEN DRAWINGS AND BUILDING SHELL. 24.CONTRACTOR TO PROVIDE FIRE EXTINGUISHERS AS REQUIRED. VERIFY QUANTITY AND LOCATION WITH LOCAL OFFICIALS AND COORDINATE LOCATION OF SAME WITH ARCHITECT. 25.GENERAL CONTRACTOR SHALL PROVIDE PEDESTRIAN PROTECTION IN FORM OF A BARRIER WHERE PEDESTRIAN TRAFFIC COMES IN CONTACT WITH CONSTRUCTION PER CBC 3303 AND OSHA REQUIREMENTS. 26.DETAILS ARE INTENDED TO SHOW METHOD AND MANNER OF ACCOMPLISHING WORK. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT THE JOB DIMENSIONS OR CONDITIONS AND SHALL BE INCLUDED AS PART OF THE WORK. 27.RETAINING WALLS SHALL BE WATERPROOFED ON THE SIDE ADJOINING THE GRADE. PROTECTION BOARD SHALL BE PART OF WATERPROOFING ASSEMBLY. 28.PROVIDE ALL NECESSARY BACKING AND FRAMING FOR WALL MOUNTED ITEMS, LIGHT FIXTURES AND ALL OTHER ITEMS REQUIRING SAME. 29.FIRE DAMPERS OR DOORS SHALL BE PROVIDED WHERE AIR DUCTS PENETRATE FIRE RATED WALLS OR CEILINGS. FIRE STOPPING SHALL BE PROVIDED AT ALL PENETRATIONS ( PIPE, DUCTS, CONDUITS CABLES AND WIRING NOT IN CONDUITS ) AS PER ASTM E 814-94. 30.NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE IN-DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND. 31.THE CONSTRUCTION OR DEMOLITION OF ANY BUILDING, STRUCTURE, SCAFFOLDING OR FALSE WORK MORE THAN 3 STORIES OR 36 FEET IN HEIGHT REQUIRES A PERMIT FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY, PRIOR TO ISSUANCE OF A BUILDING PERMIT. CONTRACTOR SHALL ONLY UTILIZE APPLICABLE TYPICAL GENERAL NOTES B. PERMITS 1.ALL COSTS FOR INSPECTIONS, TESTS, AND BUILDING PERMITS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE IN THE SPECIFICATIONS. A.SEPARATE PERMITS SHALL BE OBTAINED FOR PEDESTRIAN PROTECTION, DEMOLITION, FABRIC AWNINGS, METAL CANOPIES, PLUMBING, ELECTRICAL, MECHANICAL WORK, FIRE SPRINKLER, AND FIRE ALARM AS REQUIRED BY THE LOCAL GOVERNING AGENCIES OR FIRE SPRINKLER AND FIRE ALARM AGENCIES. 2.THE CONSTRUCTION OR DEMOLITION OF ANY BUILDING, STRUCTURE, SCAFFOLDING OR FALSEWORK MORE THAN 3 STORIES OR 36' IN HEIGHT, REQUIRES A PERMIT FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT (HSC 17922.5). C. TEMPORARY FACILITIES 1.THE CONTRACTOR SHALL MAKE ALL NECESSARY ARRANGEMENTS FOR CONSTRUCTION WATER AND POWER. WHEN APPLICABLE DUST SHALL BE CONTROLLED BY WATERING AS REQUIRED. 2.CONTRACTOR SHALL PROVIDE PEDESTRIAN PROTECTION PER C.B.C. 3.ALL COMBUSTIBLES CONSISTING OF BOXES, SCRAP LUMBER, ETC., ON THE CONSTRUCTION SITE SHALL BE CLEANED UP AND DISPOSED OF IN AN APPROVED MANNER ON A DAILY BASIS. 4.A MINIMUM OF ONE (1) 2A:10BC RATED EXTINGUISHER SHALL BE PROVIDED FOR EACH SALES OFFICE AND/OR CONSTRUCTION SHED. 5.VEHICULAR ACCESS MUST BE PROVIDED AND MAINTAINED SERVICEABLE THROUGHOUT CONSTRUCTION. 6.CONTRACTOR TO INCLUDE COST FOR ALL REQUIRED STAKING. D. TENANT BUILDING SIGNAGE 1.SIGN CONTRACTOR SHALL ACQUIRE SEPARATE BUILDING DEPARTMENT PERMITS FOR INSTALLATION OF ALL SIGNS AS REQUIRED BY LOCAL CODES. (N.I.C.) 2.GENERAL CONTRACTOR SHALL FURNISH AND INSTALL BLOCKING, ELECTRICAL JUNCTION BOX(ES), AND ACCESS PANELS. COORDINATE LOCATION(S) WITH SIGN CONTRACTOR. E. EXCAVATION & BACKFILL 1."NO TRENCHES OR EXCAVATIONS 5'-0" OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND", OR OBTAIN NECESSARY PERMITS FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY PRIOR TO ISSUANCE OF BUILDING OR GRADING PERMIT. 2.AFTER THE REQUIRED EXCAVATIONS, ANY CUT AREAS IN WHICH THE EXPOSED NATURAL GROUND HAS BEEN DISTURBED SHOULD BE SCARIFIED TO A MINIMUM DEPTH BROUGHT TO PROPER MOISTURE-CONTENT, AND COMPACTED AS ENGINEERED FILL IN ACCORDANCE WITH THE SOILS REPORT. 3.SOIL EXCAVATION AND RECOMPACTION IF REQUIRED SHALL BE DONE UNDER THE SUPERVISION OF A REGISTERED SOILS ENGINEER, ALL DENSITIES, MOISTURE CONTENT AND TESTING SHALL BE APPROVED BY THE SOIL ENGINEER PRIOR TO APPLYING THE FINISH SURFACES INDICATED ON THE DRAWINGS. ONE COPY OF ALL CERTIFICATION AND TESTS SHALL BE SENT TO THE ARCHITECT. 4.THE SOILS ENGINEER SHALL BE NOTIFIED AT LEAST 24 HOURS PRIOR TO COMMENCEMENT OF ANY EXCAVATION. 5.ALL FILL AND BACKFILL MATERIAL SHALL BE APPROVED BY THE SOILS ENGINEER. F. UTILITIES 1.THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ANY AND ALL EXISTING UTILITY LINES OR STRUCTURES WITHIN THE CONSTRUCTION AREA, WHETHER SHOWN OR NOT SHOWN HEREON. CALL DIG ALERT 1-800-227-2600 2 WORKING DAYS PRIOR TO DIGGING 2.CONTRACTOR SHALL TAG ALL CONNECTION LOCATIONS WHERE FINISH SURFACES ARE PERMANENT. (I.E. CONCRETE, A.C. PAVING ETC.) G. CONCRETE 1.REFER TO STRUCTURAL DRAWINGS AND SPECS FOR ANY ADDITIONAL NOTES. 2.THE GENERAL CONTRACTOR SHALL COORDINATE AND VERIFY WITH THE PLUMBING, MECHANICAL, ELECTRICAL, FIRE SPRINKLER, AND FIRE ALARM CONTRACTORS THE SIZE AND LOCATION OF ALL PIPING, DUCTWORK, TRENCHES, SLEEVES, SPECIAL BOLTING FOR EQUIPMENT CONDUITS, ETC., THROUGH AND UNDER CONCRETE SLABS PRIOR TO POURING OF FOOTINGS AND FLOOR SLABS. 3.NO FLOORS TO BE POURED UNTIL ALL PLUMBING, FIRE SPRINKLER, ELECTRICAL AND MECHANICAL INSTALLATIONS HAVE BEEN APPROVED BY AND GOVERNING AGENCIES. 4.INTERIOR CONCRETE SLABS SHALL BE POURED LEVEL (UNLESS OTHERWISE INDICATED) 1/8" TOLERANCE ON A 10'-0" EDGE IN ANY GIVEN DIRECTION. 5.TROWEL AND RETROWEL SLAB FOR SMOOTH FINISH WITH NO TROWEL MARKS SHOWING WHEREVER CONCRETE FLOOR IS EXPOSED. 6.COVER ALL CONCRETE SLAB SURFACES WITH CURING PAPER BEFORE POURING ADJACENT CONCRETE SLABS OR ASPHALTIC CONCRETE PAVING. CONCRETE CONTRACTOR SHALL BE RESPONSIBLE FOR SPLASHING OF FRESH CONCRETE. H. MISCELLANEOUS METAL 1.ALL ROOF OPENINGS LARGER THAN 8" X 8" GIVING ACCESS TO THE BUILDING SHALL BE SECURED BY GENERAL CONTRACTOR WITH EITHER IRON BARS, SPACING NOT TO EXCEED 6" O.C. (BOTH WAYS), METAL GATES, STAMPED METAL OR SHALL BE ALARMED AND MEET WITH APPROVAL OF THE POLICE DEPT. AND TENANT. I. FRAMING 1.REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL NOTES. 2.GENERAL CONTRACTOR SHALL INSTALL SOLID BLOCKING AS REQUIRED FOR ALL WALL MOUNTED ACCESSORIES. 3.NO STRUCTURAL MEMBER SHALL BE CUT FOR PIPES, DUCTS, ETC., UNLESS SPECIFICALLY DETAILED. 4.ALL INTERIOR WALLS AND PARTITIONS SHALL BE DESIGNED AND CONSTRUCTED TO RESIST ALL LOADS TO WHICH THEY ARE SUBJECTED BUT NOT LESS THAN A FORCE OF 5 POUNDS PER SQUARE FOOT APPLIED PERPENDICULAR TO THE WALLS. 5.THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL BOLTS, NAILS, FRAMING CLIPS, WASHERS, PLATES, HANGERS, FLASHING AND JOINTS ETC., FOR A COMPLETE INSTALLATION WHETHER OR NOT SPECIFIED OR INDICATED ON THE PLANS. 6.ALL SILLS SHALL BE PRESSURE TREATED DOUGLAS FIR. 7.ALL WOOD NOTED ON DRAWINGS TO BE FIRE-TREATED SHALL BE FIRE RETARDANT WOOD, IMPREGNATED WITH CHEMICALS PER C.B.C. REQUIREMENTS FOR FIRE-TREATED WOOD. 8.COORDINATION AND COOPERATION: PERFORM WORK IN A FULLY COORDINATED AND COOPERATIVE MANNER WITH WORK OF OTHER RELATED TRADES TO PROVIDE A COMPLETE INSTALLATION AS DETAILED AND SPECIFIED TO PROVIDE UNIFORM MATCH WITH LIKE MATERIALS FURNISHED AND INSTALLED BY OTHER TRADES. J. ACCESS DOOR & PANELS 1.CONTRACTOR SHALL PROVIDE ACCESS PANELS AS REQUIRED BY PLUMBING, FIRE SPRINKLER, MECHANICAL, ELECTRICAL AND OTHER INSTALLERS AS REQUIRED BY CODE. 2.PROVIDE RATED ACCESS PANEL @ ALL RATED WALL, FLOOR/CEILING, AND CEILING ROOF ASSEMBLIES. 3.LOCATION OF TACTILE (BRAILLE) EXIT SIGNAGE: A. EACH GRADE-LEVEL EXTERIOR EXIT DOOR SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORD, 'EXIT'. B. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS OF A STAIRWAY OR RAMP SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITHT THE FOLLOWING WORDS AS APPROPRIATE: a. 'EXIT STAIR DOWN' b. 'EXIT RAMP DOWN' c. 'EXIT STAIR UP' d. 'EXIT RAMP UP' C.EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS OF AN EXIT ENCLOSURE THAT DOES NOT UTILIZE A STAIR OR RAMP, OR BY MENAS OF AN EXIT PASSAGEWAY, SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS "EXIT ROUTE." D.EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA THAT IS REQUIRED TO HAVE A VISUAL EXIT SIGN, SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS, 'EXIT ROUTE'. E.EACH EXIT DOOR THROUGH A HORIZONTAL EXIT SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS, "TO EXIT". O. PLUMBING 1.REFER TO PLUMBING DRAWINGS FOR ADDITIONAL NOTES. 2.AN APPROVED SEISMIC GAS SHUTOFF SHALL BE INSTALLED ON THE GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE GAS PIPES. 3.CONTRACTOR SHALL PROVIDE AND INSTALL GAS SHUT-OFF VALVE CONSPICUOUSLY MARKED OUTSIDE OF BUILDING (TITLE 19) 4.PROVIDE LOW CONSUMPTION PLUMBING FIXTURES FOR ALL NEW CONSTRUCTION. P. FIRE SPRINKLERS ( DESIGN BUILD) 1.THE BUILDING IS FULLY SPRINKLERED THROUGHOUT. THE DESIGN BUILD CONTRACTOR SHALL BE RESPONSIBLE FOR A COMPLETE SYSTEM, FROM CONNECTION TO THE SITE WATER MAIN, TO THE INTERIOR BUILDING PLUMBING. 2.AUTOMATIC FIRE SPRINKLER SYSTEM TO BE HYDRAULICALLY CALCULATED CONFORMING WITH UNIFORM BUILDING CODE AND TENANT REQUIREMENTS. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND HYDRAULIC CALCS. OF AUTOMATIC FIRE SPRINKLER TO GOVERNING AGENCIES FOR APPROVAL PRIOR TO WORK IN THE FIELD. SHOP DRAWINGS SHALL BEAR STAMPED APPROVALS FROM ALL AUTHORIZED AGENCIES AND BY ANY OTHER AGENCIES WHOSE APPROVALS ARE REQUIRED BY THE DRAWINGS AND SPECIFICATIONS. 3.THE AUTOMATIC SPRINKLER SYSTEM SHALL HAVE A SUPPLY RISER WITH AN APPROVED INDICATING CONTROL VALVE AUTOMATICALLY MONITORED AND INTERCONNECTED BY MEANS OF A TELEPHONE LEASE LINE SO AS TO INDICATE AN ALARM AT CENTRAL STATION PANELS AT ANY TIME WATER IS TRANSMITTED THROUGH THE SYSTEM OR THE SUPPLY VALVES ARE CLOSED. THE FIRE DEPARTMENT CONNECTION SHALL BE LOCATED AT A LOCATION DETERMINED BY THE FIRE DEPARTMENT. 4.AUTOMATIC FIRE SPRINKLERS MUST BE IN FULL OPERATIONAL USE AND "ON" PRIOR TO FIXTURIZATION OF TENANT'S LEASE SPACE. 5.COMMERCIAL DUMPSTERS OR CONTAINERS WITH AN INDIVIDUAL CAPACITY OF 1.5 CUBIC YARDS OR GREATER SHALL NOT BE STORED OR PLACED WITHIN FIVE FEET OF COMBUSTIBLE WALLS, OPENINGS OR COMBUSTIBLE ROOF EAVE LINES UNLESS AREAS CONTAINING DUMPSTERS ARE PROTECTED BY AN APPROVED SPRINKLER SYSTEM. FIRE CODE 1103.2.2. Q. MECHANICAL 1.REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL NOTES. 2.COMBINATION FIRE AND SMOKE DAMPERS SHALL BE PROVIDED WHERE AIR DUCTS PENETRATE FIRE-RATED WALLS OR CEILINGS. CONTRACTOR SHALL PROVIDE REQUIRED CONSTRUCTION EVEN WHEN NOT SPECIFICALLY DETAILED. 3.AIR CONDITIONING AND VENT DUCTS SHALL BE DIRECTED AWAY FROM ANY ADJACENT RESIDENTIAL USES. 4.ALL MECHANICAL EQUIPMENT LOCATED ON THE ROOF SHALL BE SCREENED AND LOCATED AWAY FROM ADJOINING RESIDENTIAL USES. SCREENING DESIGN SHALL BE APPROVED BY THE PLANNING DEPARTMENT AND BUILDING DEPT. S. FIRE ALARM (DESIGN BUILD) 1.THE DESIGN BUILD CONTRACTOR SHALL BE RESPONSIBLE FOR A COMPLETE SYSTEM. 2.FIRE ALARM SYSTEM SHALL CONFORM TO GOVERNING AGENCY ADA-AMERICAN DISABILITIES ACT AND TENANT UNIT REQUIREMENT. SUBMIT SHOP DRAWINGS TO GOVERNING AGENCIES AND ARCHITECT FOR APPROVAL PRIOR TO WORK IN FIELD. 3.COORDINATE WORK WITH FIRE SPRINKLER CONTRACTOR. 4.REFER TO SHEET AR-1.1 FOR ADDTITIONAL NOTES. T. TITLE-24 ENERGY REQUIREMENTS NONRESIDENTIAL ENERGY (TITLE-24) MANDATORY MEASURES ENVELOPE 1.INSTALLED INSULATING MATERIAL SHALL HAVE BEEN CERTIFIED BY THE MANUFACTURER TO COMPLY WITH THE CALIFORNIA QUALITY STANDARDS FOR INSULATING MATERIAL, TITLE 20, CHAPTER 4, ARTICLE 3. 2.ALL INSULATING MATERIALS SHALL BE INSTALLED IN COMPLIANCE WITH THE FLAME SPREAD RATING AND SMOKE DENSITY REQUIREMENTS OF C.B.C. 719, CHAPTERS 23 AND 26, AND CALIFORNIA MECHANICAL CODES. 3.ALL EXTERIOR JOINTS AND OPENINGS IN THE BUILDING THAT ARE OBSERVABLE SOURCES OF AIR LEAKAGE SHALL BE CAULKED, GASKETED, WEATHERSTRIPPED OR OTHERWISE SEALED. 4.SITE CONSTRUCTED DOORS, WINDOWS AND SKYLIGHTS SHALL BE CAULKED BETWEEN THE UNIT AND THE BUILDING, AND SHALL BE WEATHERSTRIPPED (EXCEPT FOR UNFRAMED GLASS DOORS AND FIRE DOORS). 5.MANUFACTURED DOORS AND WINDOWS INSTALLED SHALL HAVE AIR INFILTRATION RATES NOT EXCEEDING THOSE SHOWN IN TABLE NUMBER 1-E. OF THE STANDARDS. MANUFACTURES FENESTRATION PRODUCTS MUST BE LABELED FOR U-VALUE ACCORDING TO NFRC PROCEDURES. 6.DEMISING WALLS IN NONRESIDENTIAL BUILDINGS: THE OPAQUE PORTIONS OF FRAMED DEMISING WALLS IN NONRESIDENTIAL BUILDINGS SHALL HAVE INSULATION WITH AN INSTALLED R-VALUE OF NO LESS THAN R-11 BETWEEN FRAMING MEMBERS. 7.GENERAL CONTRACTOR SHALL SIGN AND SUBMIT TO THE DEPARTMENT OF BUILDING AND SAFETY A "CERTIFICATE OF COMPLIANCE" STATING THAT THE WORK HAS BEEN PERFORMED AND MATERIALS INSTALLED ACCORDING TO THE PLANS AND SPECIFICATIONS AFFECTING NON- RESIDENTIAL ENERGY. T. SECURITY REQUIREMENTS 1.GLAZED OPENINGS WITHIN 40' OF THE DOOR LOCK WHEN THE DOOR IS IN THE CLOSED POSITION SHALL BE FULLY TEMPERED GLASS. 2.DOOR STOPS OF IN-SWINGING DOORS SHALL BE ONE-PIECE CONSTRUCTION WITH THE JAMB AT EXTERIOR DOORS. 3.PIN-TYPE HINGES WHICH ARE ACCESSIBLE FROM OUTSIDE WHEN THE DOOR IS CLOSED SHALL HAVE NON-REMOVABLE HINGE PINS. IN ADDITION, THEY SHALL HAVE MINIMUM 1/4" DIAMETER STEEL JAMB STUD WITH 1/4" MINIMUM PROJECTION UNLESS THE HINGES ARE SHAPED TO PREVENT REMOVAL OF THE DOOR IF THE HINGE PINS ARE REMOVED. 4.DEAD BOLTS SHALL CONTAIN HARDENED INSERTS. 5.STRAIGHT DEADBOLTS SHALL HAVE A MINIMUM THROW OF 1" AND AN EMBEDMENT OF NOT LESS THAN 5/8". 6.A HOOK-SHAPED OR AN EXPANDING LUG DEADBOLT SHALL HAVE MINIMUM THROW OF 3/4". 7.CYLINDER GUARDS SHALL BE INSTALLED ON ALL CYLINDER LOCKS WHENEVER THE CYLINDER PROJECTS BEYOND THE FACE OF THE DOOR OR IS OTHERWISE ACCESSIBLE TO GRIPPING TOOLS. A0.1 GENERAL NOTES K. INTERIOR FINISHES 5.INTERIOR FINISHES AND FLAME PROOFING MUST CONFORM TO THE REQUIREMENTS OF CHAPTER 8, CALIFORNIA BUILDING CODE. 6.ALL DECORATIVE MATERIALS ARE REQUIRED TO BE MAINTAINED IN A FLAME-RETARDANT CONDITION. 7.EXIT DOORS, EXIT SIGNS, FIRE ALARM SENDING STATIONS, FIRE EXTINGUISHER LOCATION SHALL NOT BE CONCEALED OR OBSTRUCTED BY ANY DECORATIVE MATERIALS. 8.ALL GYPSUM WALL BOARD SHALL CONFORM TO CHAPTER 25 OF THE UNIFORM BUILDING CODE. 9.ACCESSORIES SUCH AS GRAB BARS, TOWEL BARS, PAPER DISPENSERS AND SOAP DISHES, ETC., PROVIDED ON OR WITHIN WALLS, SHALL BE INSTALLED AND SEALED TO PROTECT STRUCTURAL ELEMENTS FROM MOISTURE. L. EXTERIOR FINISHES 1.PROVIDE A MINIMUM OF 15 LBS. ASPHALT FELT AS MOISTURE PROTECTION BEHIND EXTERIOR FINISHES AND TRIM U.N.O. FELTS TO BE INORGANIC. 2.ALL EXPOSED EXTERIOR METAL FITTINGS, FLASHING, CONDUIT, ETC. SHALL BE PAINTED TO MATCH ADJACENT SURFACES. REFER TO SPECIFICATIONS, SEE ELEVATIONS FOR EXCEPTIONS. M. SPECIALTIES 1.PROVIDE MIN. ONE (1) PORTABLE CLASS 2A: 10BC FIRE EXTINGUISHER FOR EACH TENANT. LOCATE WITHIN SEVENTY-FIVE (75) FEET FROM ANY POINT WITHIN THE TENANT SPACE. PROVIDE ADDITIONAL PORTABLE FIRE EXTINGUISHERS AS REQUIRED BY THE FIRE DEPARTMENT FIELD INSPECTOR. 2.PROVIDE FIRE DEPARTMENT "KNOX-BOX" KEY ENTRY SYSTEMS FOR EACH BUILDING OR PORTION THEREOF AS DIRECTED BY THE LOCAL GOVERNING FIRE DEPT., THAT WILL HOUSE KEYS TO UNLOCK DOORS AT ALL TENANT ENTRIES. IF REQUIRED BY FIRE DEPT. N. STREET ADDRESS & ROOM SIGNAGE 1.STREET ADDRESS NUMBERS SHALL CONFORM TO C.B.C. 501.2 AND THE FOLLOWING: A.NUMBERS SHALL BE NO SMALLER THAN 8" (EIGHT) INCHES IN HEIGHT OR AS REQUIRED BY LOCAL PUBLIC AGENCY, WITH WIDTH PROPORTIONATE TO HEIGHT. B.NUMBERS SHALL BE OF A COLOR IN CONTRAST TO THAT OF THE BACKGROUND UPON WHICH THEY ARE MOUNTED. C.NUMBERS SHALL BE LOCATED ON: 1.1.A SIGN LOCATED NEAR THE ENTRANCE TO THE BUILDING OR COMPLEX WITH STREET NUMBERS AND NAME OF COMPLEX ON IT, OR 1.2.ON A PROMINENT PORTION OF THE BUILDING NEAREST THE STREET SO THAT THE NAME AND/OR NUMBER CAN BE EASILY SEEN FROM THE STREET FRONTING ON THE PROPERTY. D.THE SIGN SHALL BE KEPT CLEAR OF ALL FOLIAGE. 2.PROVIDE A ROOM OCCUPANCY SIGN PER C.B.C. 1004.3 AND AS DIRECTED BY THE DEPT. OF BUILDING AND SAFETY/FIRE DEPARTMENT. R. ELECTRICAL 1.REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL NOTES. 2.ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING SITE CONDITIONS, SERVICE REQUIREMENTS, AND EXACT LOCATIONS OF SERVICE FACILITIES. 3.ELECTRICAL CONTRACTOR SHALL CHECK WITH OTHER TRADES FOR LOCATION OF EQUIPMENT WHICH REQUIRES ANY HOOK-UP, DISCONNECT SWITCHES, RELAYS, ETC. PRIOR TO ANY START OF WORK. 4.LOCATIONS SHOWN ON ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER ELECTRICAL DRAWINGS. 5.ALL EXTERIOR LIGHTING DEVICES ARE TO BE INACCESSIBLE TO COMMON REACH, OR CLIMBING, OR SHALL BE PROTECTED FROM WEATHER AND BE VANDALISM-RESISTANT. ALL EXTERIOR LIGHTING SHALL BE SHIELDED SO AS NOT TO CAST LIGHT ONTO ADJOINING PROPERTIES. 6.ALL EXTERIOR DOORS TO BUILDING SHALL BE EQUIPPED WITH AN ILLUMINATION DEVICE CAPABLE OF PROVIDING A MINIMUM OF ONE (1) FOOT CANDLE OF MAINTAINED ILLUMINATION AT GROUND LEVEL DURING HOURS OF DARKNESS. 7.INTERIOR NIGHT LIGHTING SHALL BE MAINTAINED IN THOSE AREAS THAT ARE VISIBLE FROM THE STREET (GROUND FLOOR ONLY). 8.EXIT SIGNS WHERE NOTED SHALL BE WORDED "EXIT" IN LETTERS SIX INCHES (6") HIGH AND SHALL CONFORM WITH GOVERNING BUILDING CODES AND REGULATIONS. PROVIDE ILLUMINATED EXIT SIGNS WHERE NOTED AND/OR REQUIRED BY CODE. ILLUMINATED EXIT SIGNS SHALL BE LIGHTED AND WIRED ON SEPARATE CIRCUIT. 9.EXITS SHALL BE ILLUMINATED AT ANYTIME THE BUILDING IS OCCUPIED WITH A LIGHT HAVING AN INTENSITY OF NOT LESS THAN ONE FOOT- CANDLE AT FLOOR LEVEL PER U.B.C. AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 A0.4a GREEN BUILDING CODE NON - RESIDENTIAL MANDATORY MEASURES CHAPTER 5 NONRESIDENTIAL MANDATORY MEASURES SECTION 5.101 GENERAL 5.101.1 SCOPE The provisions of this chapter outline planning, design and development methods that include environmentally responsible site selection, building design, building siting and development to protect, restore and enhance the environmental quality of the site and respect the integrity of adjacent properties. DIVISION 5.1 PLANNING AND DESIGN NONRESIDENTIAL MANDATORY MEASURES, SHEET 1 (January 2023) Y SECTION 5.102 DEFINITIONS 5.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) CUTOFF LUMINAIRES. Luminaires whose light distribution is such that the candela per 1000 lamp lumens does not numerically exceed 25 (2.5 percent) at an angle of 90 degrees above nadir, and 100 (10 percent) at a vertical angle of 80 degrees above nadir. This applies to all lateral angles around the luminaire. LOW-EMITTING AND FUEL EFFICIENT VEHICLES. Eligible vehicles are limited to the following: 1. Zero emission vehicle (ZEV), enhanced advanced technology PZEV (enhanced AT ZEV) or transitional zero emission vehicles (TZEV) regulated under CCR, Title 13, Section 1962. 2. High-efficiency vehicles, regulated by U.S. EPA, bearing a fuel economy and greenhouse gas rating od 9 oe 10 as regulated under 40 CFR Section 600 Subpart D. NEIGHBORHOOD ELECTRIC VEHICLE (NEV). A motor vehicle that meets the definition of "low-speed vehicle" either in Section 385.5 of the Vehicle Code or in 49CFR571.500 (as it existed on July 1, 2000), and is certified to zero-emission vehicle standards. TENANT-OCCUPANTS. Building occupants who inhabit a building during its normal hours of operation as permanent occupants, such as employees, as distinguished from customers and other transient visitors. VANPOOL VEHICLE. Eligible vehicles are limited to any motor vehicle, other than a motortruck or truck tractor, designed for carrying more than 10 but not more than 15 persons including the driver, which is maintained and used primarily for the nonprofit work-related transportation of adults for the purpose of ridesharing. Note: Source: Vehicle Code, Division 1, Section 668 ZEV. Any vehicle certified to zero-emission standards. SECTION 5.106 SITE DEVELOPMENT 5.106.1 STORM WATER POLLUTION PREVENTION FOR PROJECTS THAT DISTURB LESS THAN ONE ACRE OF LAND. Newly constructed projects and additions which disturb less than one acre of land, and are not part of a larger common plan of development or sale, shall prevent the pollution of storm water runoff from the construction activities through one or more of the following measures: 5.106.1.1 Local ordinance. Comply with a lawfully enacted storm water management and/or erosion control ordinance. 5.106.1.2 Best Management Practices (BMPs). Prevent the loss of soil through wind or water erosion by implementing an effective combination of erosion and sediment control and good housekeeping BMPs. 1. Soil loss BMPs that should be considered for implementation as appropriate for each project include, but are not limited to, the following: a. Scheduling construction activity during dry weather, when possible. b. Preservation of natural features, vegetation, soil, and buffers around surface waters. c. Drainage swales or lined ditches to control stormwater flow. d. Mulching or hydroseeding to stabilize disturbed soils. e. Erosion control to protect slopes. f. Protection of storm drain inlets (gravel bags or catch basin inserts). g. Perimeter sediment control (perimeter silt fence, fiber rolls). h. Sediment trap or sediment basin to retain sediment on site. i. Stabilized construction exits. j. Wind erosion control. k. Other soil loss BMPs acceptable to the enforcing agency. 2. Good housekeeping BMPs to manage construction equipment, materials, non-stormwater discharges and wastes that should be considered for implementation as appropriate for each project include, but are not limited to, the following: a. Dewatering activities. b. Material handling and waste management. c. Building materials stockpile management. d. Management of washout areas (concrete, paints, stucco, etc.). e. Control of vehicle/equipment fueling to contractor's staging area. f. Vehicle and equipment cleaning performed off site. g Spill prevention and control. h. Other housekeeping BMPs acceptable to the enforcing agency. DIVISION 5.2 ENERGY EFFICIENCY SECTION 5.201 GENERAL 5.201.1 Scope [BSC-CG]. California Energy Code [DSA-SS]. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory building standards. DIVISION 5.3 WATER EFFICIENCY AND CONSERVATION SECTION 5.301 GENERAL 5.301.1 Scope. The provisions of this chapter shall establish the means of conserving water use indoors, outdoors and in wastewater conveyance. SECTION 5.302 DEFINITIONS 5.302.1 Definitions. The following terms are defined in Chapter 2 (and are included here for reference) EVAPOTRANSPIRATION ADJUSTMENT FACTOR (ETAF) [DSA-SS]. An adjustment factor when applied to reference evapotranspiration that adjusts for plant factors and irrigation efficiency, which ae two major influences on the amount of water that needs to be applied to the landscape. FOOTPRINT AREA [DSA-SS]. The total area of the furthest exterior wall of the structure projected to natural grade, not including exterior areas such as stairs, covered walkways, patios and decks. METERING FAUCET. A self-closing faucet that dispenses a specific volume of water for each actuation cycle. The volume or cycle duration can be fixed or adjustable. GRAYWATER. Pursuant to Health and Safety Code Section 17922.12, "graywater" means untreated wastewater that has not been contaminated by any toilet discharge, has not been affected by infectious, contaminated, or unhealthy bodily wastes, and does not present a threat from contamination by unhealthful processing, manufacturing, or operating wastes. "Graywater" includes, but is not limited to wastewater from bathtubs, showers, bathroom washbasins, clothes washing machines and laundry tubs, but does not include waste water from kitchen sinks or dishwashers. MODEL WATER EFFICIENT LANDSCAPE ORDINANCE (MWELO). The California ordinance regulating landscape design, installation and maintenance practices that will ensure commercial, multifamily and other developer installed landscapes greater than 2500 square feet meet an irrigation water budget developed based on landscaped area and climatological parameters. MODEL WATER EFFICIENT LANDSCAPE ORDINANCE (MWELO). [HCD] The California model ordinance (California Code of Regulations, Title 23, Division 2, Chapter 2.7), regulating landscape design, installation and maintenance practices. Local agencies are required to adopt the updated MWELO, or adopt a local ordinance at least as effective as the MWELO. POTABLE WATER. Water that is drinkable and meets the U.S. Environmental Protection Agency (EPA) Drinking Water Standards. See definition in the California Plumbing Code, Part 5. POTABLE WATER. [HCD] Water that is satisfactory for drinking, culinary, and domestic purposes, and meets the U.S. Environmental Protection Agency (EPA) Drinking Water Standards and the requirements of the Health Authority Having Jurisdiction. RECYCLED WATER. Water which, as a result of treatment of waste, is suitable for a direct beneficial use or a controlled use that would not otherwise occur [Water Code Section 13050 (n)]. Simply put, recycled water is water treated to remove waste matter attaining a quality that is suitable to use the water again. SUBMETER. [HCD 1] A secondary device beyond a meter that measures water consumption of an individual rental unit within a multiunit residential structure or mixed-use residential and commercial structure. (See Civic Code Section 1954.202 (g) and Water code Section 517 for additional details.) WATER BUDGET. Is the estimated total landscape irrigation water use which shall not exceed the maximum applied water allowance calculated in accordance with the Department of Water Resources Model Efficient Landscape Ordinance (MWELO). 5.106.5.3 Electric vehicle (EV) charging. [N] Construction to provide electric vehicle infrastructure and facilitate electric vehicle charging shall comply with Section 5.106.5.3.1 and shall be provided in accordance with regulations in the California Building Code and the California Electrical Code. Exceptions: 1.On a case-by-case basis where the local enforcing agency has determined compliance with this section is not feasible based upon one of the following conditions: a.Where there is no local utility power supply b.Where the local utility is unable to supply adequate power. c.Where there is evidence suitable to the local enforcement agency substantiating the local utility infrastructure design requirements, directly related to the implementation of Section 5.106.5.3, may adversely impact the construction cost of the project. 2. Parking spaces accessible only by automated mechanical car parking systems are not required to comply with this code section 5.106.5.3.1 EV capable spaces. [N] EV capable spaces shall be provided in accordance with Table 5.106.5.3.1 and the following requirements: 1.Raceways complying with the California Electrical Code and no less that 1-inch (25 mm) diameter shall be provided and shall originate at a service panel or a subpanel(s) serving the area, and shall terminate in close proximity to the proposed location of the EV capable and into a suitable listed cabinet, box,enclosure or equivalent. A common raceway may be used to serve multiple EV charging spaces. 2.A service panel or subpanel (s) shall be provided with panel space and electrical load capacity for a dedicated 208/240 volt, 40-ampere minimum branch circuit for each EV capable space, with delivery of 30-ampere minimum to an installed EVSE at each EVCS. 3.The electrical system and any on-site distribution transformers shall have sufficient capacity to supply full rated amperage at each EV capable space. 4.The service panel or subpanel circuit directory shall identify the reserved overcurrent protective devices space(s) as "EV CAPABLE". The raceway termination location shall be permanently and visibly marked as "EV CAPABLE." Note: A parking space served by electric vehicle supply equipment or designed as a future EV charging space shall count as at least one standard automobile parking space only for the purpose of complying with any applicable minimum parking space requirements established by an enforcement agency. See vehicle Code Section 22511.2 for further details. ABBREVIATION DEFINITIONS: HCD Department of Housing and Community Development BSC California Building Standards Commission DSA-SS Division of the State Architect, Structural Safety OSHPD Office of Statewide Health Planning and Development LR Low Rise HR High Rise AA Additions and Alterations N New 5.106.4.1.2 Long-term bicycle parking. For new buildings with tenant spaces that have 10 or more tenant-occupants, provide secure bicycle parking for 5 percent of the tenant-occupant vehicular parking spaces with a minimum of one bicycle parking facility. 5.106.4.1.3 For additions or alterations that add 10 or more tenant-occupant vehicular parking spaces, provide secure bicycle parking for 5 percent of the tenant vehicular parking spaces being added, with a minimum of one bicycle parking facility. 5.106.4.1.4 For new shell buildings in phased projects provide secure bicycle parking for 5 percent of the anticipated tenant-occupant vehicular parking spaces with a minimum of one bicycle parking facility. 5.106.4.1.5 Acceptable bicycle parking facility for Sections 5.106.4.1.2, 5.106.4.1.3, and 5.106.4.1.4 shall be convenient from the street and shall meet one of the following: 1. Covered, lockable enclosures with permanently anchored racks for bicycles; 2. Lockable bicycle rooms with permanently anchored racks; or 3. Lockable, permanently anchored bicycle lockers. Note: Additional information on recommended bicycle accommodations may be obtained from Sacramento Area Bicycle Advocates. 5.106.4.2 Bicycle parking. [DSA-SS] For public schools and community colleges, comply with Sections 5.106.4.2.1 and 5.106.4.2.2 5.106.4.2.1 Student bicycle parking. Provide permanently anchored bicycle racks conveniently accessed with a minimum of four two-bike capacity racks per new building. 5.106.4.2.2 Staff bicycle parking. Provide permanent, secure bicycle parking conveniently accessed with a minimum of two staff bicycle parking spaces per new building. Acceptable bicycle parking facilities shall be convenient from the street or staff parking area and shall meet one of the following: 1. Covered, lockable enclosures with permanently anchored racks for bicycles; 2. Lockable bicycle rooms with permanently anchored racks; or 3. Lockable, permanently anchored bicycle lockers. 5.106.4 BICYCLE PARKING. For buildings within the authority of California Building Standards Commission as specified in Section 103, comply with Section 5.106.4.1. For buildings within the authority of the Division of the State Architect pursuant to Section 105, comply with Section 5.106.4.2 5.106.4.1 Bicycle parking. [BSC-CG] Comply with Sections 5.106.4.1.1 and 5.106.4.1.2; or meet the applicable local ordinance, whichever is stricter. 5.106.4.1.1 Short-term bicycle parking. If the new project or an addition or alteration is anticipated to generate visitor traffic, provide permanently anchored bicycle racks within 200 feet of the visitors' entrance, readily visible to passers-by, for 5% of new visitor motorized vehicle parking spaces being added, with a minimum of one two-bike capacity rack. Exception: Additions or alterations which add nine or less visitor vehicular parking spaces. CHAPTER 3 GREEN BUILDING SECTION 301 GENERAL 301.1 SCOPE. Buildings shall be designed to include the green building measures specified as mandatory in the application checklists contained in this code. Voluntary green building measures are also included in the application checklists and may be included in the design and construction of structures covered by this code, but are not required unless adopted by a city, county, or city and county as specified in Section 101.7. 301.3 NONRESIDENTIAL ADDITIONS AND ALTERATIONS. [BSC-CG] The provisions of individual sections of Chapter 5 apply to newly constructed buildings, building additions of 1,000 square feet or greater, and/or building alterations with a permit valuation of $200,000 or above (for occupancies within the authority of California Building Standards Commission). Code sections relevant to additions and alterations shall only apply to the portions of the building being added or altered within the scope of the permitted work. A code section will be designated by a banner to indicate where the code section only applies to newly constructed buildings [N] or to additions and/or alterations [A]. When the code section applies to both, no banner will be used. 301.3.1 Nonresidential additions and alterations that cause updates to plumbing fixtures only: Note: On and after January 1, 2014, certain commercial real property, as defined in Civil Code Section 1101.3, shall have its noncompliant plumbing fixtures replaced with appropriate water-conserving plumbing fixtures under specific circumstances. See Civil Code Section 1101.1 et seq. for definitions, types of commercial real property affected, effective dates, circumstances necessitating replacement of noncompliant plumbing fixtures, and duties and responsibilities for ensuring compliance. 301.3.2 Waste Diversion. The requirements of Section 5.408 shall be required for additions and alterations whenever a permit is required for work. 301.4 PUBLIC SCHOOLS AND COMMUNITY COLLEGES. (see GBSC) 301.5 HEALTH FACILITIES. (see GBSC) SECTION 302 MIXED OCCUPANCY BUILDINGS 302.1 MIXED OCCUPANCY BUILDINGS. In mixed occupancy buildings, each portion of a building shall comply with the specific green building measures applicable to each specific occupancy. SECTION 303 PHASED PROJECTS 303.1 PHASED PROJECTS. For shell buildings and others constructed for future tenant improvements, only those code measures relevant to the building components and systems considered to be new construction (or newly constructed) shall apply. 303.1.1 Initial Tenant improvements. The provisions of this code shall apply only to the initial tenant improvements to a project. Subsequent tenant improvements shall comply with the scoping provisions in Section 301.3 non-residential additions and alterations. 5.106.5.3.3 Use of automatic load management systems (ALMS). ALMS shall be permitted for EVCS. When ALMS is installed, the required electrical load capacity specified in Section 5.106.5.3.1 for each EVCS may be reduced when serviced by an EVSE controlled by an ALMS. Each EVSE controlled by an ALMS shall deliver a minimum 30 amperes to an EV when charging one vehicle and shall deliver a minimum 3.3 kW while simultaneously charging multiple EVs. 5.106.5.3.4 Accessible EVCS. When EVSE is installed, accessible EVSC shall be provided in accordance with the California Building Code, Chapter 11B, Section 11B-228.3. Note: For EVCS signs, refer to Caltrans Traffic Operations Policy Directive 13-01 (Zero Emission Vehicle Signs and Pavement Markings) or its successor(s). 5.106.5.4 Electric Vehicle (EV) charging: medium-duty and heavy-duty. [N] Construction shall comply with section 5.106.5.4.1 to facilitate future installation of electric vehicle supply equipment (EVSE). Construction for warehouses, grocery stores and retail stores with planned off-street loading spaces shall also comply with Section 5.106.5.4.1 for future installation of medium- and heavy-duty EVSE. Exceptions: 1.On a case-by-case basis where the local enforcing agency has determined compliance with this section is not feasible based upon one of the following conditions: a.Where there is no local utility power supply. b.Where the local utility is unable to supply adequate power. c.Where there is evidence suitable to the local enforcing agency substantiating that additional local utility infrastructure design requirements, directly related to the implementation of Section 5.106.5.3, may adversely impact the construction cost of the project. When EVSE(s) is/are installed, it shall be in accordance with the California Building Code, the California Electrical Code and as follows: 5.106.5.4.1 Electric vehicle charging readiness requirements for warehouse, grocery stores and retail stores with planned off-street loading spaces. [N]In order to avoid future demolition when adding EV charging supply and distribution equipment, spare raceways(s) or busway(s) and adequate capacity for transformers(s), service panels(s) or subpanel(s) shall be installed at the time of construction in accordance with the California Electrical Code. Construction plans and specifications shall include but are not limited to, the following: 1.The transformer, main service equipment and subpanel shall meet the minimum power requirement in Table 5.106.5.4.1 to accommodate the dedicated branch circuits for the future installation of EVSE. 2.The construction documents shall indicate on or more location(s) convenient to the planned offstreet loading space(s) reserved for medium-and heavy-duty ZEV charging cabinets and charging dispensers, and a pathway reserved for routing of conduit from the termination of the raceway(s) or busway(s) to the charging cabinet(s) and dispenser(s) as shown in Table 5.106.5.4.1 3.Raceway(s) or busway(s) originating at a main service panel or a subpanel(s) serving the area where potential future medium-and heavy-duty EVSE will be located and shall terminate in close proximity to the potential future location of the charging equipments for medium- and heavy-duty vehicles. 4.The raceway(s) or busway(s) shall be sufficient size to carry the minimum additional system load to the future location of the charging for medium- and heavy-duty ZEVs as shown in Table 5.106.5.4.1. TABLE 5.106.5.3.1 TOTAL NUMBER OF ACTUAL PARKING SPACES NUMBER OF REQUIRED EV CAPABLE SPACES NUMBER OF EVCS (EV CAPABLE SPACES PROVIDED WITH EVSE)^2 0-9 0 0 10-25 2 0 26-50 8 2 51-75 13 3 76-100 17 4 101-150 25 6 151-200 35 9 201 AND OVER 20% of total¹25% of EV capable spaces¹ 5.106.8 LIGHT POLLUTION REDUCTION. [N]. l Outdoor lighting systems shall be designed and installed to comply with the following: 1.The minimum requirements in the California Energy Code for Lighting Zones 0-4 as defined in Chapter 10, Section 10-114 of the California Administrative Code; and 2.Backlight (B) ratings as defined in IES TM-15-11 (shown in Table A-1 in Chapter 8); 3.Uplight and Glare ratings as defined in California Energy Code (shown in Tables 130.2-A and 130.2-B in Chapter 8) and 4.Allowable BUG ratings not exceeding those shown in Table 5.106.8, [N] or Comply with a local ordinance lawfully enacted pursuant to Section 101.7, whichever is more stringent. Exceptions: [N] 1. Luminaires that qualify as exceptions in Sections 130.2 (b) and 140.7 of the California Energy Code. 2. Emergency lighting. 3. Building facade meeting the requirements in Table 140.7-B of the California Energy Code, Part 6. 4. Custom lighting features as allowed by the local enforcing agency, as permitted by Section 101.8 Alternate materials, designs and methods of construction. 5. Luminaires with less than 6,200 initial luminaire lumens. TABLE 5.106.8 [N] MAXIMUM ALLOWABLE BACKLIGHT, UPLIGHT AND GLARE (BUG) RATINGS 1,2 ALLOWABLE RATING LIGHTING ZONE LZ0 LIGHTING ZONE LZ1 LIGHTING ZONE LZ2 LIGHTING ZONE LZ3 LIGHTING ZONE LZ4 MAXIMUM ALLOWABLE BACKLIGHT RATING 3 Luminaire greater than 2 mounting heights (MH) from property line N/A No Limit No Limit No Limit No Limit Luminaire back hemisphere is 1-2 MH from property line N/A B2 B3 B4 B4 Luminaire back hemisphere is 0.5-1 MH from property line N/A B1 B2 B3 B3 Luminaire back hemisphere is less than 0.5 MH from property line N/A B0 B0 B1 B2 MAXIMUM ALLOWABLE UPLIGHT RATING (U) For area lighting 3 N/A U0 U0 U0 U0 For all other outdoor lighting,including decorative luminaires N/A U1 U2 U3 UR DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. 5.106.2 STORMWATER POLLUTION PREVENTION FOR PROJECTS THAT DISTURB ONE OR MORE ACRES OF LAND. Comply with all lawfully enacted stormwater discharge regulations for projects that (1) disturb one acre or more of land, or (2) disturb less than one acre of land but are part of a larger common plan of development sale. Note: Projects that (1) disturb one acre or more of land, or (2) disturb less than one acre of land but are part of the larger common plan of development or sale must comply with the post-construction requirements detailed in the applicable National Pollutant Discharge Elimination System (NPDES) General permit for Stormwater Discharges Associated with Construction and Land Disturbance Activities issued by the State Water Resources Control Board or the Lahontan Regional Water Quality Control Board (for projects in the Lake Tahoe Hydrologic Unit). The NPDES permits require postconstruction runoff (post-project hydrology) to match the preconstruction runoff (pre-project hydrology) with the installation of postconstruction stormwater management measures. The NPDES permits emphasize runoff reduction through on-site stormwater use, interception, evapotranspiration, and infiltration through nonstructural controls, such as Low Impact Development (LID) practices, and conversation design measures. Stormwater volume that cannot be addressed using nonstructural practices is required to be captured in structural practices and be approved by the enforcing agency. Refer to the current applicable permits on the State Water Resources Control Board website at: www.waterboards.ca.gov/constructionstormwater. Consideration to the stormwater runoff management measures should be given during the initial design process for appropriate integration into site development. N/A Y N/A 1.Where there is insufficient electrical supply. 2.The number of required EVCS (EV capable spaces provided with EVSE) in column 3 count towards the total number of required EV capable spaces shown in column 2. 5.106.5.3.2 Electric vehicle charging stations (EVCS) EV capable spaces shall be provided with EVSE to create EVCS in the number indicated in Table 5.106.5.3.1. The EVCS required by Table 5.106.5.3.1 may be provided with EVSE in any combination of Level 2 and Direct Current Fast Charging (DCFC), except that at least one Level 2 EVSE shall be provided. One EV charger with multiple connectors capable of charging multiple EVs simultaneously shall be permitted if the electrical load capacity required by Section 5.106.5.3.1 for each EV capable space is accumulatively supplied to the EV charger. The installation of each DCFC EVSE shall be permitted to reduce the minimum number of required EV capable spaces without EVSE by five and reduce proportionally the required electrical load capacity to the service panel or subpanel. Y N/A Y N/A Y = YES N/A =NOT APPLICABLE RESPON. PARTY =RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) RESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 5.106.8.1 Facing- Backlight Luminaries within 2MH of a property line shall be oriented so that the nearest property line is behind the fixture, and shall comply with the backlight rating specified in Table 5.106.8 based on the lighting zone and distance to the nearest point of that property line. Exception: Corners. If two property lines (or two segments of the same property line) have equidistant point to the luminaire, then the luminaire may be oriented so that the intersection of the two lines (the corner) is directly behind the luminaire. The luminaire shall still use the distance to the nearest points(s) on the property lines to determine the required backlight rating. 5.106.8.2 Facing-Glare. For luminaires covered by 5.106.8.1, if a property line also exists within or extends into the front hemisphere within 2MH of the luminaire then the luminaire shall comply with the more stringent glare rating specified in Table 5.106.8 based on the lighting zone and distance to the nearest point on the nearest property line within the front hemisphere. Note: [N] 1.See also California Building Code, Chapter 12, Section 1205.6 for college campus lighting requirements for parking facilities and walkways. 2.Refer to Chapter 8 (Compliance Forms, Worksheets and Reference Material) for IES TM-15-11 Table A-1, California Energy Code Tables 130.2-A and 130.2-B. 3. Refer to the California Building Code for requirements for additions and alterations. 5.106.10 GRADING AND PAVING. Construction plans shall indicate how site grading or a drainage system will manage all surface water flows to keep water from entering buildings. Examples of methods to manage surface water include, but are not limited to, the following: 1.Swales. 2.Water collection and disposal systems. 3.French drains. 4.Water retention gardens. 5.Other water measures which keep surface water away from buildings and aid in groundwater recharge. Exception: Additions and alterations not altering the drainage path. 5.106.12 SHADE TREES [DSA-SS]. Shade Trees shall be planted to comply with Sections 5.106.12.1, 5.106.12.2, and 5.106.12.3. Percentages shown shall be measured at noon on the summer solstice. Landscape irrigation necessary to establish and maintain tree health shall comply with Section 5.304.6. 5.106.12.1 Surface parking areas. Shade tree plantings, minimum #10 container size or equal, shall be installed to provide shade over 50 percent of the parking area within 15 years. Exceptions: Surface parking area covered by solar photovoltaic shade structures with roofing materials that comply with Table A5.106.11.2.2 in Appendix A5 shall be permitted in whole or in part in lieu of shade tree planting. 5.106.12.2 Landscape areas. Shade tress plantings, minimum #10 container size or equal shall be installed to provide shade of 20% of the landscape area within 15 years. Exceptions: Playfields for organized sport activity are not included in the total area calculation. 5.106.12.3. Hardscape areas. Shade tree plantings, minimum #10 container size or equal shall be installed to provide shade over 20 percent of the hardscape area within 15 years. Exceptions: 1.Walks, hardscape areas covered by solar photovoltaic shade structures or shade structures with roofing materials that comply with Table A5.106.11.2.2 in Appendix A5 shall be permitted in whole or in part in lieu of shade tree planting. 2.Designated and marked play areas of organized sport activity are not included in the total area calculation. TABLE 5.106.5.4.1 RACEWAY CONDUIT AND PANEL POWER REQUIREMENTS FOR MEDIUM- AND HEAVY-DUTY EVSE [N] BUILDING TYPE BUILDING SIZE (SQ. FT.) NUMBER OF OFF-STREET LOADING SPACES ADDITIONAL CAPACITY REQUIRED (KVA) FOR RACEWAY & BUSWAY AND TRANSFORMER & PANEL Grocery 10,000 to 90,000 1 or 2 200 3 or Greater 400 Greater than 90,000 1 or Greater 400 Retail 10,000 to 135,000 1 or 2 200 3 or Greater 400 Greater than 135,000 1 or Greater 400 Warehouse 20,000 to 256,000 1 or 2 200 3 or Greater 400 Greater than 256,000 1 or Greater 400 MAXIMUM ALLOWABLE GLARE RATING 5 (G) MAXIMUM ALLOWABLE GLARE RATING 5 (G)N/A G1 G2 G3 G4 MAXIMUM ALLOWABLE GLARE RATING 5 (G)N/A G0 G1 G1 G2 MAXIMUM ALLOWABLE GLARE RATING 5 (G)N/A G0 G0 G1 G1 MAXIMUM ALLOWABLE GLARE RATING 5 (G)N/A G0 G0 G0 G1 1. IESNA Lighting Zones 0 and 5 are not applicable; refer to Lighting Zones as defined in the California Energy Code and Chapter 10 of the Callifornia Administrative Code. 2. For property lines that abut public walkways, bikeways, plazas and parking lots, the property line may be considered to be 5 feet beyond the actual property line for purpose of determining compliance with this section. For property lines that abut public roadways and public transit corridors, the property line may be considered to be the centerline of the public roadway or public transit corridor for the purpose of determining compliance with this section. 3. General lighting luminaires in areas such as outdoor parking, sales or storage lots shall meet these reduced ratings. Decorative luminaries located in these areas shall meet U-value limits for "all other outdoor lighting" AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 A0.4b GREEN BUILDING CODE NON - RESIDENTIAL MANDATORY MEASURES 5.303.3 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the following: 5.303.3.1 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank-type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Tank-Type toilets. Note: The effective flush volume of dual flush toilets is defined as the composite, average flush volume of two reduced flushes and one full flush. 5.303.3.2 Urinals. 5.303.3.2.1 Wall-mounted Urinals. The effective flush volume of wall-mounted urinals shall not exceed 0.125 gallons per flush. 5.303.3.2.2 Floor-mounted Urinals. The effective flush volume of floor-mounted or other urinals shall not exceed 0.5 gallons per flush. 5.303.3.3 Showerheads. [BSC-CG] 5.303.3.3.1 Single showerhead. Showerheads shall have a maximum flow rate of not more than 1.8 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Showerheads. 5.303.3.3.2 Multiple showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all the showerheads and/or other shower outlets controlled by a single valve shall not exceed 1.8 gallons per minute at 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Note: A hand-held shower shall be considered a showerhead. DIVISION 5.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY SECTION 5.401 GENERAL 5.401.1 SCOPE. The provisions of this chapter shall outline means of achieving material conservation and resource efficiency through protection of buildings from exterior moisture, construction waste diversion, employment of techniques to reduce pollution through recycling of materials, and building commissioning or testing and adjusting. SECTION 5.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING 5.408.1 CONSTRUCTION WASTE MANAGEMENT. Recycle and/or salvage for reuse a minimum of 65% of the non-hazardous construction and demolition waste in accordance with Section 5.408.1.1, 5.408.1.2 or 5.408.1.3; or meet a local construction and demolition waste management ordinance, whichever is more stringent. 5.408.1.1 Construction waste management plan. Where a local jurisdiction does not have a construction and demolition waste management ordinance, submit a construction waste management plan that: 1. Identifies the construction and demolition waste materials to be diverted from disposal by efficient usage, recycling, reuse on the project or salvage for future use or sale. 2. Determines if construction and demolition waste materials will be sorted on-site (source-separated) or bulk mixed (single stream). 3. Identifies diversion facilities where construction and demolition waste material collected will be taken. 4. Specifies that the amount of construction and demolition waste materials diverted shall be calculated byweight or volume, but not by both. 5.408.1.2 Waste Management Company. Utilize a waste management company that can provide verifiable documentation that the percentage of construction and demolition waste material diverted from the landfill complies with this section. Note: The owner or contractor shall make the determination if the construction and demolition waste material will be diverted by a waste management company. Exceptions to Sections 5.408.1.1 and 5.408.1.2: 1. Excavated soil and land-clearing debris. 2. Alternate waste reduction methods developed by working with local agencies if diversion or recycle facilities capable of compliance with this item do not exist. 3. Demolition waste meeting local ordinance or calculated in consideration of local recycling facilities and markets. 5.408.1.3 Waste stream reduction alternative. The combined weight of new construction disposal that does not exceed two pounds per square foot of building area may be deemed to meet the 65% minimum requirement as approved by the enforcing agency. 5.408.1.4 Documentation. Documentation shall be provided to the enforcing agency which demonstrates compliance with Sections 5.408.1.1, through 5.408.1.3. The waste management plan shall be updated as necessary and shall be accessible during construction for examination by the enforcing agency. Notes: 1. Sample forms found in "A Guide to the California Green Building Standards Code (Nonresidential)" located www.dgs.ca.gov/BSC/Resources/Page-Content/Building-Standards-Commission- Resources-List-Folder/CALGreen may be used to assist in documenting compliance with the waste management plan. 2. Mixed construction and demolition debris processors can be located at the California Department of Resources Recycling and Recovery (CalRecycle). 5.408.2 UNIVERSAL WASTE. [A] Additions and alterations to a building or tenant space that meet the scoping provisions in Section 301.3 for nonresidential additions and alterations, shall require verification that Universal Waste items such as fluorescent lamps and ballast and mercury containing thermostats as well as other California prohibited Universal Waste materials are disposed of properly and are diverted from landfills. A list of prohibited Universal Waste materials shall be included in the construction documents. Note: Refer to the Universal Waste Rule link at: http://www.dtsc.ca.gov/universalwaste/ 5.408.3 EXCAVATED SOIL AND LAND CLEARING DEBRIS. 100 percent of trees, stumps, rocks and associated vegetation and soils resulting primarily from land clearing shall be reused or recycled. For a phased project, such material may be stockpiled on site until the storage site is developed. Exception: Reuse, either on or off-site, of vegetation or soil contaminated by disease or pest infestation. Notes: 1. If contamination by disease or pest infestation is suspected, contact the County Agricultural Commissioner and follow its direction for recycling or disposal of the material. 2. For a map of know pest and/or disease quarantine zones, consult with the California Department of Food and Agriculture. (www.cdfa.ca.gov) DIVISION 5.5 ENVIRONMENTAL QUALITY SECTION 5.501 GENERAL 5.501.1 SCOPE. The provisions of this chapter shall outline means of reducing the quantity of air contaminants that are odorous, irritating, and/or harmful to the comfort and well-being of a building's installers, occupants and neighbors. SECTION 5.502 DEFINITIONS 5.502.1 DEFINITIONS. The following terms are defined in Chapter 2 (and are included here for reference) ARTERIAL HIGHWAY. A general term denoting a highway primarily for through traffic usually on a continuous route. A-WEIGHTED SOUND LEVEL (dBA). The sound pressure level in decibels as measured on a sound level meter using the internationally standardized A-weighting filter or as computed from sound spectral data to which A-weighting adjustments have been made. 1 BTU/HOUR. British thermal units per hour, also referred to as Btu. The amount of heat required to raise one pound of water one degree Fahrenheit per hour, a common measure of heat transfer rate. A ton of refrigeration is 12,000 Btu, the amount of heat required to melt a ton (2,000 pounds) of ice at 320 Fahrenheit. COMMUNITY NOISE EQUIVALENT LEVEL (CNEL). A metric similar to the day-night average sound level (Ldn), except that a 5 decibel adjustment is added to the equivalent continuous sound exposure level for evening hours (7pm to 10pm) in addition to the 10 dB nighttime adjustment used in the Ldn. COMPOSITE WOOD PRODUCTS. Composite wood products include hardwood plywood, particleboard and medium density fiberboard. “Composite wood products” does not include hardboard, structural plywood, structural panels, structural composite lumber, oriented strand board, glued laminated timber, timber, prefabricated wood I–joists or finger–jointed lumber, all as specified in California Code of Regulations (CCR), Title 17, Section 93120.1(a). Note: See CCR, Title 17, Section 93120.1. DAY-NIGHT AVERAGE SOUND LEVEL (Ldn). The A-weighted equivalent continuous sound exposure level for a 24-hour period with a 10 dB adjustment added to sound levels occurring during nighttime hours (10p.m. to 7 a.m.). DECIBEL (db). A measure on a logarithmic scale of the magnitude of a particular quantity (such as sound pressure, sound power, sound intensity) with respect to a reference quantity. ELECTRIC VEHICLE (EV). An automotive-type vehicle for on-road use, such as passenger automobiles, buses, trucks, vans, neighborhood electric vehicles, electric motorcycles, and the like, primarily powered by an electric motor that draws current from a rechargeable storage battery, fuel cell, photovoltaic array, or other source of electric current. Plug-in hybrid electric vehicles (PHEV) are considered electric vehicles. For purposes of the California Electrical Code, off-road, self-propoelled electric vehicles, such as industrial trucks, hoists, lifts, transports, golf carts, airline ground support equipment, tractors, boats, and the like, are not included. ELECTRIC VEHICLE CHARGING STATION(S) (EVCSj). One or more spaces intended for charging electric vehicles. ELECTRIC VEHICLE SUPPLY EQUIPMENT (EVSE). The conductors, including the ungrounded, grounded, and equipment grounding conductors and the electric vehicle connectors, attachment plugs, and all other fittings, devices, power outlets, or apparatus installed specifically for the purpose of transferring energy between the premises wiring and the electric vehicle. ENERGY EQUIVALENT (NOISE) LEVEL (Leq). The level of a steady noise which would have the same energy as the fluctuating noise level integrated over the time of period of interest. EXPRESSWAY. An arterial highway for through traffic which may have partial control of access, but which may or may not be divided or have grade separations at intersections. FREEWAY. A divided arterial highway with full control of access and with grade separations at intersections. GLOBAL WARMING POTENTIAL (GWP). The radiative forcing impact of one mass-based unit of a given greenhouse gas relative to an equivalent unit of carbon dioxide over a given period of time. Carbon dioxide is the reference compound with a GWP of one. GLOBAL WARMING POTENTIAL VALUE (GWP VALUE). A 100-year GWP value published by the Intergovernmental Panel on Climate Change (IPCC) in either its Second Assessment Report (SAR) (IPCC, 1995); or its Fourth Assessment A-3 Report (AR4) (IPCC, 2007). The SAR GWP values are found in column "SAR (100-yr)" of Table 2.14.; the AR4 GWP values are found in column "100 yr" of Table 2.14. HIGH-GWP REFRIGERANT. A compound used as a heat transfer fluid or gas that is: (a) a chlorofluorocarbon, a hdrochlorofluorocarbon, a hydrofluorocarbon, a perfluorocarbon, or any compound or blend of compounds, with a GWP value equal to or greater than 150, or (B) any ozone depleting substance as defined in Title 40 of the Code of Federal Regulations, Part 82, sec.82.3 (as amended March 10, 2009). LONG RADIUS ELBOW. Pipe fitting installed between two lengths of pipe or tubing to allow a change of direction, with a radius 1.5 times the pipe diameter. LOW-GWP REFRIGERANT. A compound used as a heat transfer fluid or gas that: (A) has a GWP value less than 150, and (B) is not an ozone depleting substance as defined in Title 40 of the Code of Federal Regulations, Part 82, sec.82.3 (as amended March 10, 2009). MERV. Filter minimum efficiency reporting value, based on ASHRAE 52.2–1999. MAXIMUM INCREMENTAL REACTIVITY (MIR). The maximum change in weight of ozone formed by adding a compound to the "Base REactive Organic Gas (ROG) Mixture" per weight of compound added, expressed to hundreths of a gram (g O3/g ROC). PRODUCT-WEIGHTED MIR (PWMIR). The sum of all weighted-MIR for all ingredients in a product subject to this article. The PWMIR is the total product reactivity expressed to hundredths of a gram of ozone formed per gram of product (excluding container and packaging). PSIG. Pounds per square inch, guage. REACTIVE ORGANIC COMPOUND (ROC). Any compound that has the potential, once emitted, to contribute to ozone formation in the troposphere. SCHRADER ACCESS VALVES. Access fittings with a valve core installed. SHORT RADIUS ELBOW. Pipe fitting installed between two lengths of pipe or tubing to allow a change of direction, with a radius 1.0 times the pipe diameter. SUPERMARKET. For the purposes of Section 5.508.2, a supermarket is any retail food facility with 8,000 square feet or more conditioned area, and that utilizes either refrigerated display cases, or walk-in coolers or freezers connected to remote compressor units or condensing units. VOC. A volatile organic compound broadly defined as a chemical compound based on carbon chains or rings with vapor pressures greater than 0.1 millimeters of mercury at room temperature. These compounds typically contain hydrogen and may contain oxygen, nitrogen and other elements. See CCR Title 17, Section 94508(a) . Note: Where specific regulations are cited from different agencies such as SCAQMD, ARB, etc., the VOC definition included in that specific regulation is the one that prevails for the specific measure in question. SECTION 5.503 FIREPLACES 5.503.1 FIREPLACES. Install only a direct-vent sealed-combustion gas or sealed wood-burning fireplace, or a sealed woodstove or pellet stove, and refer to residential requirements in the California Energy Code, Title 24, Part 6, Subchapter 7, Section 150. Woodstoves, pellet stoves and fireplaces shall comply with applicable local ordinances. 5.503.1.1 Woodstoves. Woodstoves and pellet stoves shall comply with U.S. EPA New Source Performance Standards (NSPS) emission limits as applicable, and shall have a permanent label indicating they are certified to meet the emission limits. SECTION 5.504 POLLUTANT CONTROL 5.504.1 TEMPORARY VENTILATION. The permanent HVAC system shall only be used during construction if necessary to condition the building or areas of addition or alteration within the required temperature range for material and equipment installation. If the HVAC system is used during construction, use return air filters with a Minimum Efficiency Reporting Value (MERV) of 8, based on ASHRAE 52.2-1999, or an average efficiency of 30% based on ASHRAE 52.1-1992 Replace all filters immediately prior to occupancy, or, if the building is occupied during alteration, at the conclusion of construction. 5.504.3 Covering of duct openings and protection of mechanical equipment during construction. At the time of rough installation and during storage on the construction site until final startup of the heating, cooling and ventilation equipment, all duct and other related air distribution component openings shall be covered with tape, plastic, sheetmetal or other methods acceptable to the enforcing agency to reduce the amount of dust, water and debris which may enter the system. 5.410.2.1 Owner's or Owner Representative's Project Requirements (OPR). [N] The expectations and requirements of the building appropriate to its phase shall be documented before the design phase of the project begins. This documentation shall include the following: 1. Environmental and sustainability goals. 2. Building sustainable goals. 3. Indoor environmental quality requirements. 4. Project program, including facility functions and hours of operation, and need for after hours operation. 5. Equipment and systems expectations. 6. Building occupant and operation and maintenance (O&M) personnel expectations. 5.410.2.2 Basis of Design (BOD). [N] A written explanation of how the design of the building systems meets the OPR shall be completed at the design phase of the building project. The Basis of Design document shall cover the following systems: 1. Renewable energy systems. 2. Landscape irrigation systems. 3. Water reuse system. 5.410.2.3 Commissioning plan. [N] Prior to permit issuance a commissioning plan shall be completed to document how the project will be commissioned. The commissioning plan shall include the following: 1. General project information. 2. Commissioning goals. 3. Systems to be commissioned. Plans to test systems and components shall include: a. An explanation of the original design intent. b. Equipment and systems to be tested, including the extent of tests. c. Functions to be tested. d. Conditions under which the test shall be performed. e. Measurable criteria for acceptable performance. 4. Commissioning team information. 5. Commissioning process activities, schedules and responsibilities. Plans for the completion of commissioning shall be included. 5.410.2.4 Functional performance testing. [N] Functional performance tests shall demonstrate the correct installation and operation of each component, system and system-to-system interface in accordance with the approved plans and specifications. Functional performance testing reports shall contain information addressing each of the building components tested, the testing methods utilized, and include any readings and adjustments made. 5.410.2.6 Commissioning report. [N] A report of commissioning process activities undertaken through the design and construction phases of the building project shall be completed and provided to the owner or representative. 5.410.4 TESTING AND ADJUSTING. New buildings less than 10,000 square feet. Testing and adjusting of systems shall be required for new buildings less than 10,000 square feet or new systems to serve an addition or alteration subject to Section 303.1. 5.410.4.2 (Reserved) Note: For energy-related systems under the scope (Section 100) of the California Energy Code, including heating, ventilation, air conditioning (HVAC) systems and controls, indoor lighting system and controls, as well as water heating systems and controls, refer to California Energy Code Section 120.8 for commissioning requirements and Sections 120.5, 120.6, 130.4, and 140.9(b)3 for additional testing requirements of specific systems. 5.410.4.2 Systems. Develop a written plan of procedures for testing and adjusting systems. Systems to be included for testing and adjusting shall include at a minimum, as applicable to the project: 1. Renewable energy systems. 2. Landscape irrigation systems. 3. Water reuse systems. 5.410.4.3 Procedures. Perform testing and adjusting procedures in accordance with manufacturer's specifications and applicable standards on each system. 5.410.4.3.1 HVAC balancing. In addition to testing and adjusting, before a new space-conditioning system serving a building or space is operated for normal use, the system shall be balanced in accordance with the procedures defined by the Testing Adjusting and Balancing Bureau National Standards; the National Environmental Balancing Bureau Procedural Standards; Associated Air Balance Council National Standards or as approved by the enforcing agency. NONRESIDENTIAL MANDATORY MEASURES, SHEET 2 (January 2023) SECTION 5.303 INDOOR WATER USE 5.303.1 METERS. Separate submeters or metering devices shall be installed for the uses described in Sections 503.1.1 and 503.1.2. 5.303.1.1 Buildings in excess of 50,000 square feet. Separate submeters shall be installed as follows: 1. For each individual leased, rented or other tenant space within the building projected to consume more than 100 gal/day (380 L/day), including, but not limited to, spaces used for laundry or cleaners, restaurant or food service, medical or dental office, laboratory, or beauty salon or barber shop. SECTION 5.410 BUILDING MAINTENANCE AND OPERATIONS 5.410.1 RECYCLING BY OCCUPANTS. Provide readily accessible areas that serve the entire building and are identified for the depositing, storage and collection of non-hazardous materials for recycling, including (at a minimum) paper, corrugated cardboard, glass, plastics, organic waste, and metals or meet a lawfully enacted local recycling ordinance, if more restrictive. Exception: Rural jurisdictions that meet and apply for the exemption in Public Resources Code 42649.82 (a)(2)(A) et seq. shall also be exempt from the organic waste portion of this section. 5.410.1.1 Additions. All additions conducted within a 12-month period under single or multiple permits, resulting in an increase of 30% or more in floor area, shall provide recycling areas on site. Exception: Additions within a tenant space resulting in less than a 30% increase in the tenant space floor area. 5.410.1.2 Sample ordinance. Space allocation for recycling areas shall comply with Chapter 18, Part 3, Division 30 of the Public Resources Code. Chapter 18 is known as the California Solid Waste Reuse and Recycling Access Act of 1991 (Act). Note: A sample ordinance for use by local agencies may be found in Appendix A of the document at the CalRecycle’s web site. 5.410.2.5 Documentation and training. [N] A Systems Manual and Systems Operations Training are required, including Occupational Safety and Health Act (OSHA) requirements in California Code of Regulations (CCR), Title 8, Section 5142, and other related regulations. 5.410.2.5.1 Systems manual. [N] Documentation of the operational aspects of the building shall be completed within the systems manual and delivered to the building owner or representative. The systems manual shall include the following: 1. Site information, including facility description, history and current requirements. 2. Site contact information. 3. Basic operations and maintenance, including general site operating procedures, basic troubleshooting, recommended maintenance requirements, site events log. 4. Major systems. 5. Site equipment inventory and maintenance notes. 6. A copy of verifications required by the enforcing agency or this code. 7. Other resources and documentation, if applicable. 5.410.2.5.2 Systems operations training. [N] A program for training of the appropriate maintenance staff for each equipment type and/or system shall be developed and documented in the commissioning report and shall include the following: 1. System/equipment overview (what it is, what it does and with what other systems and/or equipment it interfaces). 2. Review and demonstration of servicing/preventive maintenance. 3. Review of the information in the Systems Manual. 4. Review of the record drawings on the system/equipment. 2. Where separate submeters for individual building tenants are unfeasible, for water supplied to the following subsystems: a. Makeup water for cooling towers where flow through is greater than 500 gpm (30 L/s). b. Makeup water for evaporative coolers greater than 6 gpm (0.04 L/s). c. Steam and hot water boilers with energy input more than 500,000 Btu/h (147 kW). 5.303.1.2 Excess consumption. A separate submeter or metering device shall be provided for any tenant within a new building or within an addition that is projected to consume more than 1,000 gal/day. SECTION 5.304 OUTDOOR WATER USE 5.304.1 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. Nonresidential developments shall comply with a local water efficient landscape ordinance or the current California Department of Water Resources' Model Water Efficient Landscape Ordinance (MWELO), whichever is more stringent. Notes: 1. The Model Water Efficient Landscape Ordinance (MWELO) is located in the California Code of Regulations, Title 23, Chapter 2.7, Division 2. 2. MWELO and supporting documents, including a water budget calculator, are available at: https://www.water.ca.gov/. 5.304.6 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. For public schools and community colleges, landscape projects as described in Sections 5.304.6.1 and 5.304.6.2 shall comply with the California Department of Water Resources Model Water Efficient Landscape Ordinance (MWELO) commencing with Section 490 of Chapter 2.7, Division 2, Title 23, California Code of Regulations, except that the evapotranspiration adjustment factor (ETAF) shall be 0.65 with an additional water allowance for special landscape areas (SLA) of 0.35. Exception: Any project with an aggregate landscape area of 2,500 square feet or less may comply with the prescriptive measures contained in Appendix D of the MWELO. 5.304.6.1 Newly constructed landscapes. New construction projects with an aggregate landscape area equal to or greater than 500 square feet. 5.304.6.2 Rehabilitated landscapes. Rehabilitated landscape projects with an aggregate landscape area equal to or greater than 1,200 square feet. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. 5.303.4 COMMERCIAL KITCHEN EQUIPMENT. 5.303.4.1 Food Waste Disposers. Disposers shall either modulate the use of water to no more than 1 gpm when the disposer is not in use (not actively grinding food waste/no-load) or shall automatically shut off after no more than 10 minutes of inactivity. Disposers shall use no more than 8 gpm of water. Note: This code section does not affect local jurisdiction authority to prohibit or require disposer installation. 5.303.5 AREAS OF ADDITION OR ALTERATION. For those occupancies within the authority of the California Building Standards Commission as specified in Section 103, the provisions of Section 5.303.3 and 5.303.4 shall apply to new fixtures in additions or areas of alteration to the building. 5.303.6 STANDARDS FOR PLUMBING FIXTURES AND FITTINGS. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table 1701.1 of the California Plumbing Code and in Chapter 6 of this code. Y N/A SECTION 5.402 DEFINITIONS 5.402.1 DEFINITIONS. The following terms are defined in Chapter 2 (and are included here for reference) ADJUST. To regulate fluid flow rate and air patterns at the terminal equipment, such as to reduce fan speed or adjust a damper. BALANCE. To proportion flows within the distribution system, including sub-mains, branches and terminals, according to design quantities. BUILDING COMMISSIONING. A systematic quality assurance process that spans the entire design and construction process, including verifying and documenting that building systems and components are planned, designed, installed, tested, operated and maintained to meet the owner’s project requirements. ORGANIC WASTE. Food waste, green waste, landscape and pruning wste, nonhazardous wood waste, and food soiled paper waste that is mixed in with food waste. TEST. A procedure to determine quantitative performance of a system or equipment SECTION 5.407 WATER RESISTANCE AND MOISTURE MANAGEMENT 5.407.1 WEATHER PROTECTION. Provide a weather-resistant exterior wall and foundation envelope as required by California Building Code Section 1402.2 (Weather Protection), manufacturer's installation instructions or local ordinance, whichever is more stringent. 5.407.2 MOISTURE CONTROL. Employ moisture control measures by the following methods. 5.407.2.1 Sprinklers. Design and maintain landscape irrigation systems to prevent spray on structures. 5.407.2.2 Entries and openings. Design exterior entries and/or openings subject to foot traffic or wind-driven rain to prevent water intrusion into buildings as follows: 5.407.2.2.1 Exterior door protection. Primary exterior entries shall be covered to prevent water intrusion by using nonabsorbent floor and wall finishes within at least 2 feet around and perpendicular to such openings plus at least one of the following: 1. An installed awning at least 4 feet in depth. 2. The door is protected by a roof overhang at least 4 feet in depth. 3. The door is recessed at least 4 feet. 4. Other methods which provide equivalent protection. 5.407.2.2.2 Flashing. Install flashings integrated with a drainage plane. 5.410.2 COMMISSIONING. [N] New buildings 10,000 square feet and over. For new buildings 10,000 square feet and over, building commissioning shall be included in the design and construction processes of the building project to verify that the building systems and components meet the owner’s or owner representative’s project requirements. Commissioning shall be performed in accordance with this section by trained personnel with experience on projects of comparable size and complexity. For I-occupancies that are not regulated by OSHPD or for I-occupancies and L-occupancies that are not regulated y the California Energy Code Section 100.0 Scope, all requirements in Sections 5.410.2 through 5.410.2.6 shall apply. Note: For energy-related systems under the scope (Section 100) of the California Energy Code, including heating, ventilation, air conditioning (HVAC) systems and controls, indoor lighting systems and controls, as well as water heating systems and controls, refer to California Energy Code Section 120.8 for commissioning requirements Commissioning requirements shall include: 1. Owner’s or Owner representative’s project requirements. 2. Basis of design. 3. Commissioning measures shown in the construction documents. 4. Commissioning plan. 5. Functional performance testing. 6. Documentation and training. 7. Commissioning report. Exceptions: 1. Unconditioned warehouses of any size. 2. Areas less than 10,000 square feet used for offices or other conditioned accessory spaces within unconditioned warehouses. 3. Tenant improvements less than 10,000 square feet as described in Section 303.1.1. 4. Open parking garages of any size, or open parking garage areas, of any size, within a structure. Note: For the purposes of this section, unconditioned shall mean a building, area, or room which does not provide heating and or air conditioning. Informational Notes: 1. IAS AC 476 is an accreditation criteria for organizations providing training and/or certification of commissioning personnel. AC 476 is available to the Authority Having Jurisdiction as a reference for qualifications of commissioning personnel. AC 476 des not certify individuals to conduct functional performance tests or to adjust and balance systems. 2. Functional performance testing for heating, ventilation, air conditioning systems and lighting controls must be performed in compliance with the California Energy Code. 5.410.4.4 Reporting. After completion of testing, adjusting and balancing, provide a final report of testing signed by the individual responsible for performing these services. 5.410.4.5 Operation and maintenance (O & M) manual. Provide the building owner or representative with detailed operating and maintenance instructions and copies of guaranties/warranties for each system. O & M instructions shall be consistent with OSHA requirements in CCR, Title 8, Section 5142, and other related regulations. 5.410.4.5.1 Inspections and reports. Include a copy of all inspection verifications and reports required by the enforcing agency. Y N/A Y N/A Y N/ARESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY Y = YES N/A =NOT APPLICABLE RESPON. PARTY =RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) 5.303.3.4 Faucets and fountains. 5.303.3.4.1 Nonresidential Lavatory faucets. Lavatory faucets shall have a maximum flow rate of not more than 0.5 gallons per minute at 60 psi. 5.303.3.4.2 Kitchen faucets. Kitchen faucets shall have a maximum flow rate of not more than 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. 5.303.3.4.3 Wash fountains. Wash fountains shall have a maximum flow rate of not more than1.8 gallons per minute/20 [rim space (inches) at 60 psi]. 5.303.3.4.4 Metering faucets. Metering faucets shall not deliver more than 0.20 gallons per cycle. 5.303.3.4.5 Metering faucets for wash fountains. Metering faucets for wash fountains shall have a maximum flow rate of not more than 0.20 gallons per minute/20 [rim space (inches) at 60 psi]. Note: Where complying faucets are unavailable, aerators or other means may be used to achieve reduction. 5.303.3.4.6 Pre-rinse spray value When installed, shall meet the requirements in the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Section 1605.1 (h)(4) Table H-2, Section 1605.3 (h)(4)(A), and Section 1607 (d)(7), and shall be equipped with an integral automatic shutoff. FOR REFERENCE ONLY:The following table and code section have been reprinted from the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Section 1605.1 (h)(4) and Section 1605.3 (h)(4)(A). TABLE H-2 STANDARDS FOR COMMERCIAL PRE-RINSE SPRAY VALUES MANUFACTURED ON OR AFTER JANUARY 28, 2019 PRODUCT CLASS [spray force in ounce force (ozf)]MAXIMUM FLOW RATE (gpm) Product Class 1 (≤1.00 Product Class 2 (> 5.0 ozf and ≤1.20 Product Class 3 (> 8.0 ozf)1.28 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 A0.4c GREEN BUILDING CODE NON - RESIDENTIAL MANDATORY MEASURES 5.504.4.3 Paints and coatings. Architectural paints and coatings shall comply with VOC limits in Table 1 of the ARB Architectural Coatings Suggested Control Measure, as shown in Table 5.504.4.3, unless more stringent local limits apply. The VOC content limit for coatings that do not meet the definitions for the specialty coatings categories listed in Table 5.504.4.3 shall be determined by classifying the coating as a Flat, Nonflat or Nonflat-High Gloss coating, based on its gloss, as defined in Subsections 4.21, 4.36 and 4.37 of the 2007 California Air Resources Board Suggested Control Measure, and the corresponding Flat, Nonflat or Nonflat-High Gloss VOC limit in Table 5.504.4.3 shall apply. 5.504.4.3.1 Aerosol Paints and coatings. Aerosol paints and coatings shall meet the PWMIR Limits for ROC in Section 94522(a)(3) and other requirements, including prohibitions on use of certain toxic compounds and ozone depleting substances, in Sections 94522(c)(2) and (d)(2) of California Code of Regulations, Title 17, commencing with Section 94520; and in areas under the jurisdiction of the Bay Area Air Quality Management District additionally comply with the percent VOC by weight of product limits of Regulation 8 Rule 49. 5.504.4.4.1 Carpet cushion. All carpet cushion installed in the building interior shall meet the requirements of the California Department of Public Health,"Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers,"Version 1.2, January 2017 (Emission testing method for California Specifications 01350). See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx#material 5.504.4.4.2 Carpet adhesive. All carpet adhesive shall meet the requirements of Table 5.504.4.1. 5.504.4.5 Composite wood products. Hardwood plywood, particleboard and medium density fiberboard composite wood products used on the interior or exterior of the buildings shall meet the requirements for formaldehyde as specified in ARB's Air Toxics Control Measure (ATCM) for Composite Wood (17 CCR 93120 et seq.). Those materials not exempted under the ATCM must meet the specified emission limits, as shown in Table 5.504.4.5. 5.504.4.5.3 Documentation. Verification of compliance with this section shall be provided as requested by the enforcing agency. Documentation shall include at least one of the following: 1. Product certifications and specifications. 2. Chain of custody certifications. 3. Product labeled and invoiced as meeting the Composite Wood Products regulation (see CCR, Title 17, Section 93120, et seq.). 4. Exterior grade products marked as meeting the PS-1 or PS-2 standards of the Engineered Wood Association, the Australian AS/NZS 2269 or European 636 3S standards. 5. Other methods acceptable to the enforcing agency. TABLE 5.504.4.1 - ADHESIVE VOC LIMIT1,2 Less Water and Less Exempt Compounds in Grams per Liter ARCHITECTURAL APPLICATIONS CURRENT VOC LIMIT INDOOR CARPET ADHESIVES 50 CARPET PAD ADHESIVES 50 OUTDOOR CARPET ADHESIVES 150 WOOD FLOORING ADHESIVES 100 RUBBER FLOOR ADHESIVES 60 SUBFLOOR ADHESIVES 50 CERAMIC TILE ADHESIVES 65 VCT & ASPHALT TILE ADHESIVES 50 DRYWALL & PANEL ADHESIVES 50 COVE BASE ADHESIVES 50 MULTIPURPOSE CONSTRUCTION ADHESIVES 70 STRUCTURAL GLAZING ADHESIVES 100 SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 OTHER ADHESIVES NOT SPECIFICALLY LISTED 50 SPECIALTY APPLICATIONS PVC WELDING 510 CPVC WELDING 490 ABS WELDING 325 PLASTIC CEMENT WELDING 250 ADHESIVE PRIMER FOR PLASTIC 550 CONTACT ADHESIVE 80 SPECIAL PURPOSE CONTACT ADHESIVE 250 STRUCTURAL WOOD MEMBER ADHESIVE 140 TOP & TRIM ADHESIVE 250 SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 PLASTIC FOAMS 50 POROUS MATERIAL (EXCEPT WOOD)50 WOOD 30 FIBERGLASS 80 1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER, THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED. 2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168, www.arb.ca.gov/DRDB/SC/CURHTML/R1168.PDF TABLE 5.504.4.2 - SEALANT VOC LIMIT Less Water and Less Exempt Compounds in Grams per Liter SEALANTS CURRENT VOC LIMIT ARCHITECTURAL 250 MARINE DECK 760 NONMEMBRANE ROOF 300 ROADWAY 250 SINGLE-PLY ROOF MEMBRANE 450 OTHER 420 SEALANT PRIMERS ARCHITECTURAL NONPOROUS 250 POROUS 775 MODIFIED BITUMINOUS 500 MARINE DECK 760 OTHER 750 NOTE: FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THESE TABLES, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. TABLE 5.504.4.3 - CONT. GRAMS OF VOC PER LITER OF COATING, LESS WATER & LESS EXEMPT COMPOUNDS COATING CATEGORY CURRENT VOC LIMIT SPECIALTY COATINGS ALUMINUM ROOF COATINGS 400 BASEMENT SPECIALTY COATINGS 400 BITUMINOUS ROOF COATINGS 50 BITUMINOUS ROOF PRIMERS 350 BOND BREAKERS 350 CONCRETE CURING COMPOUNDS 350 CONCRETE/MASONRY SEALERS 100 DRIVEWAY SEALERS 50 DRY FOG COATINGS 150 FAUX FINISHING COATINGS 350 FIRE RESISTIVE COATINGS 350 FLOOR COATINGS 100 FORM-RELEASE COMPOUNDS 250 GRAPHIC ARTS COATINGS (SIGN PAINTS)500 HIGH-TEMPERATURE COATINGS 420 INDUSTRIAL MAINTENANCE COATINGS 250 LOW SOLIDS COATINGS1 120 MAGNESITE CEMENT COATINGS 450 MASTIC TEXTURE COATINGS 100 METALLIC PIGMENTED COATINGS 500 MULTICOLOR COATINGS 250 PRETREATMENT WASH PRIMERS 420 PRIMERS, SEALERS, & UNDERCOATERS 100 REACTIVE PENETRATING SEALERS 350 RECYCLED COATINGS 250 ROOF COATINGS 50 RUST PREVENTATIVE COATINGS 250 SHELLACS: CLEAR 730 OPAQUE 550 SPECIALTY PRIMERS, SEALERS & UNDERCOATERS 100 STAINS 250 STONE CONSOLIDANTS 450 SWIMMING POOL COATINGS 340 TRAFFIC MARKING COATINGS 100 TUB & TILE REFINISH COATINGS 420 WATERPROOFING MEMBRANES 250 WOOD COATINGS 275 WOOD PRESERVATIVES 350 ZINC-RICH PRIMERS 340 1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER & EXEMPT COMPOUNDS 2. THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT COLUMNS IN THE TABLE. 3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, FEB. 1, 2008. MORE INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD. TABLE 5.504.4.5 - FORMALDEHYDE LIMITS1 MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION PRODUCT CURRENT LIMIT HARDWOOD PLYWOOD VENEER CORE 0.05 HARDWOOD PLYWOOD COMPOSITE CORE 0.05 PARTICLE BOARD 0.09 MEDIUM DENSITY FIBERBOARD 0.11 THIN MEDIUM DENSITY FIBERBOARD2 0.13 1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE WITH ASTM E 1333. FOR ADDITIONAL INFORMATION, SEE CALIFORNIA CODE OF REGULATIONS, TITLE 17, SECTIONS 93120 THROUGH 93120.12. 2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 5/16 INCHES (8 MM). 5.508.2 Supermarket refrigerant leak reduction. New commercial refrigeration systems shall comply with the provisions of this section when installed in retail food stores 8,000 square feet or more conditioned area, and that utilize either refrigerated display cases, or walk-in coolers or freezers connected to remote compressor units or condensing units. The leak reduction measures apply to refrigeration systems containing high-global-warming potential (high-GWP) refrigerants with a GWP of 150 or greater. New refrigeration systems include both new facilities and the replacement of existing refrigeration systems in existing facilities. Exception: Refrigeration systems containing low-global warming potential (low-GWP) refrigerant with a GWP value less than 150 are not subject to this section. Low-GWP refrigerants are nonozone-depleting refrigerants that include ammonia, carbon dioxide (CO2), and potentially other refrigerants. 5.508.2.1 Refrigerant piping. Piping compliant with the California Mechanical Code shall be installed to be accessible for leak protection and repairs. Piping runs using threaded pipe, copper tubing with an outside diameter (OD) less than 1/4 inch, flared tubing connections and short radius elbows shall not be used in refrigerant systems except as noted below. 5.508.2.1.1 Threaded pipe. Threaded connections are permitted at the compressor rack. 5.508.2.1.2 Copper pipe. Copper tubing with an OD less than 1/4 inch may be used in systems with a refrigerant charge of 5 pounds or less. 5.508.2.1.2.1 Anchorage. One-fouth-inch OD tubing shall be securely clamped to a rigid base to keep vibration levels below 8 mils. 5.508.2.1.3 Flared tubing connections. Double-flared tubing connections may be used for pressure controls, valve pilot lines and oil. Exception: Single-flared tubing connections may be used with a multiring seal coated with industrial sealant suitable for use with refrigerants and tightened in accordance with manufacturer's recommendations. 5.508.2.1.4 Elbows. Short radius elbows are only permitted where space limitations prohibit use of long radius elbows. 5.508.2.2 Valves. Valves Valves and fittings shall comply with the California Mechanical Code and as follows. 5.508.2.2.1 Pressure relief valves. For vessels containing high-GWP refrigerant, a rupture disc shall be installed between the outlet of the vessel and the inlet of the pressure relief valve. 5.508.2.2.1.1 Pressure detection. A pressure gauge, pressure transducer or other device shall be installed in the space between the rupture disc and the relief valve inlet to indicate a disc rupture or discharge of the relief valve. 5.508.2.2.2 Access valves. Only Schrader access valves with a brass or steel body are permitted for use. 5.508.2.2.2.1 Valve caps. For systems with a refrigerant charge of 5 pounds or more, valve caps shall be brass or steel and not plastic. 5.508.2.2.2.2 Seal caps. If designed for it, the cap shall have a neoprene O-ring in place. 5.508.2.2.2.2.1 Chain tethers. Chain tethers to fit ovr the stem are required for valves designed to have seal caps. Exception: Valves with seal caps that are not removed from the valve during stem operation. 5.508.2.3 Refrigerated service cases. Refrigerated service cases holding food products containing vinegar and salt shall have evaporator coils of corrosion-resistant material, such as stainless steel; or be coated to prevent corrosion from these substances. 5.508.2.3.1 Coil coating. Consideration shall be given to the heat transfer efficiency of coil coating to maximize energy efficiency. 5.508.2.4 Refrigerant receivers. Refrigerant receivers with capacities greater than 200 pounds shall be fitted with a device tha indicates the level of refrigerant in the receiver. 5.508.2.5 Pressure testing. The system shall be pressure tested during installation prior to evacuation and charging. 5.508.2.5.1 Minimum pressure. The system shall be charged with regulated dry nitrogen and appropriate tracer gas to bring system pressure up to 300 psig minimum. 5.508.2.5.2 Leaks. Check the system for leaks, repair any leaks, and retest for pressure using the same gauge. 5.508.2.5.3 Allowable pressure change. The system shall stand, unaltered, for 24 hours with no more than a +/- one pound pressure change from 300 psig, measured with the same gauge. 5.508.2.6 Evacuation. The system shall be evacuated after pressure testing and prior to charging. 5.508.2.6.1 First vacuum. Pull a system vacuum down to at least 1000 microns (+/- 50 microns), and hold for 30 minutes. 5.508.2.6.2 Second vacuum. Pull a second system vacuum to a minimum of 500 microns and hold for 30 minutes. 5.508.2.6.3 Third vacuum. Pull a third vacuum down to a minimum of 300 microns, and hold for 24 hours with a maximum drift of 100 microns over a 24-hour period. CHAPTER 7 INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS 702 QUALIFICATIONS 702.1 INSTALLER TRAINING. HVAC system installers shall be trained and certified in the proper installation of HVAC systems including ducts and equipment by a nationally or regionally recognized training or certification program. Uncertified persons may perform HVAC installations when under the direct supervision and responsibility of a person trained and certified to install HVAC systems or contractor licensed to install HVAC systems. Examples of acceptable HVAC training and certification programs include but are not limited to the following: 1. State certified apprenticeship programs. 2. Public utility training programs. 3. Training programs sponsored by trade, labor or statewide energy consulting or verification organizations. 4. Programs sponsored by manufacturing organizations. 5. Other programs acceptable to the enforcing agency. 702.2 SPECIAL INSPECTION [HCD]. When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition to other certifications or qualifications acceptable to the enforcing agency, the following certifications or education may be considered by the enforcing agency when evaluating the qualifications of a special inspector: 1. Certification by a national or regional green building program or standard publisher. 2. Certification by a statewide energy consulting or verification organization, such as HERS raters, building performance contractors, and home energy auditors. 3. Successful completion of a third party apprentice training program in the appropriate trade. 4. Other programs acceptable to the enforcing agency. Notes: 1. Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 2. HERS raters are special inspectors certified by the California Energy Commission (CEC) to rate homes in California according to the Home Energy Rating System (HERS). [BSC-CG] When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition, the special inspector shall have a certification from a recognized state, national or international association, as determined by the local agency. The area of certification shall be closely related to the primary job function, as determined by the local agency. Note: Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 703 VERIFICATIONS 703.1 DOCUMENTATION. Documentation used to show compliance with this code shall include but is not limited to, construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which demonstrate substantial conformance. When specific documentation or special inspection is necessary to verify compliance, that method of compliance will be specified in the appropriate section or identified applicable checklist. NONRESIDENTIAL MANDATORY MEASURES, SHEET 3 (January 2023) SECTION 5.505 INDOOR MOISTURE CONTROL 5.505.1 INDOOR MOISTURE CONTROL. Buildings shall meet or exceed the provisions of California Building Code, CCR, Title 24, Part 2, Sections 1202 (Ventilation) and Chapter 14 (Exterior Walls). For additional measures, see Section 5.407.2 of this code. SECTION 5.506 INDOOR AIR QUALITY 5.506.1 OUTSIDE AIR DELIVERY. For mechanically or naturally ventilated spaces in buildings, meet the minimum requirements of Section 120.1 (Requirements For Ventilation) of the California Energy Code, or the applicable local code, whichever is more stringent, and Division 1, Chapter 4 of CCR, Title 8. 5.506.2 CARBON DIOXIDE (CO2) MONITORING. For buildings or additions equipped with demand control ventilation, CO2 sensors and ventilation controls shall be specified and installed in accordance with the requirements of the California Energy Code, Section 120(c)(4). 5.506.3 Carbon dioxide (CO2) monitoring in classrooms. (DSA-SS) Each public K-12 school classroom, as listed in Table 120.1-A of the California Energy Code, shall be equipped with a carbon dioxide monitor or sensor that meets the following requirements: 1.The monitor or sensor shall be permanently affixed in a tamper-proof manner in each classroom between 3 and 6 feet (914 mm and 1829 mm) above the floor and at least 5 feet (1524 mm) away from door and operable windows. 2.When the monitor or sensor is not integral to an Energy Management Control System (EMCS), the monitor or sensor shall display the carbon dioxide readings on the device. When the sensor is integral to an EMCS, the carbon dioxide readings shall be available to and regularly monitored by facility personnel. 3.A monitor shall provide notification though a visual indicator on the monitor when the carbon dioxide levels in the classroom have exceeded 1,100ppm. A sensor integral to an EMCS shall provide notification to facility personnel through a visual and/or audible indicator when the carbon dioxide levels in the classroom have exceeded 1,100ppm. 4.The monitor or sensor shall measure carbon dioxide levels at minimum 15- minute intervals and shall maintain a record of previous carbon dioxide measurements of not less than 30 days duration. 5.The monitor or sensor used to measure carbon dioxide levels shall have the capacity to measure carbon dioxide levels with a range of 400ppm to 2000ppm or greater. 6.The monitor or sensor shall be certified by the manufacturer to be accurate within 75ppm at 1,000ppm carbon dioxide concentration and shall be certified by the manufacturer to require calibration no more frequently than once every 5 years. SECTION 5.507 ENVIRONMENTAL COMFORT 5.507.4 ACOUSTICAL CONTROL. Employ building assemblies and components with Sound Transmission Class (STC) values determined in accordance with ASTM E 90 and ASTM E 413, or Outdoor-Indoor Sound Transmission Class (OITC) determined in accordance with ASTM E 1332, using either the prescriptive or performance method in Section 5.507.4.1 or 5.507.4.2. Exception: Buildings with few or no occupants or where occupants are not likely to be affected by exterior noise, as determined by the enforcement authority, such as factories, stadiums, storage, enclosed parking structures and utility buildings. Exception: [DSA-SS] For public schools and community colleges, the requirements of this section and all subsections apply only to new construction. 5.507.4.1 Exterior noise transmission, prescriptive method. Wall and roof-ceiling assemblies exposed to the noise source making up the building or addition envelope or altered envelope shall meet a composite STC rating of at least 50 or a composite OITC rating of no less than 40, with exterior windows of a minimum STC of 40 or OITC of 30 in the following locations: 1. Within the 65 CNEL noise contour of an airport. Exceptions: 1. Ldn or CNEL for military airports shall be determined by the facility Air Installation Compatible Land Use Zone (AICUZ) plan. 2. Ldn or CNEL for other airports and heliports for which a land use plan has not been developed shall be determined by the local general plan noise element. 2. Within the 65 CNEL or Ldn noise contour of a freeway or expressway, railroad, industrial source or fixed-guideway source as determined by the Noise Element of the General Plan. 5.507.4.1.1. Noise exposure where noise contours are not readily available. Buildings exposed to a noise level of 65 dB Leq - 1-hr during any hour of operation shall have building, addition or alteration exterior wall and roof-ceiling assemblies exposed to the noise source meeting a composite STC rating of at least 45 (or OITC 35), with exterior windows of a minimum STC of 40 (or OITC 30). 5.507.4.2 Performance Method. For buildings located as defined in Section 5.507.4.1 or 5.507.4.1.1, wall and roof-ceiling assemblies exposed to the noise source making up the building or addition envelope or altered envelope shall be constructed to provide an interior noise environment attributable to exterior sources that does not exceed an hourly equivalent noise level (Leq-1Hr) of 50 dBA in occupied areas during any hour of operation. 5.507.4.2.1 Site Features. Exterior features such as sound walls or earth berms may be utilized as appropriate to the building, addition or alteration project to mitigate sound migration to the interior. 5.507.4.2.2 Documentation of Compliance. An acoustical analysis documenting complying interior sound levels shall be prepared by personnel approved by the architect or engineer of record. 5.507.4.3 Interior sound transmission. Wall and floor-ceiling assemblies separating tenant spaces and tenant spaces and public places shall have an STC of at least 40. Note: Examples of assemblies and their various STC ratings may be found at the California Office of Noise Control: www.toolbase.org/PDF/CaseStudies/stc_icc_ratings.pdf. SECTION 5.508 OUTDOOR AIR QUALITY 5.508.1 Ozone depletion and greenhouse gas reductions. Installations of HVAC, refrigeration and fire suppression equipment shall comply with Sections 5.508.1.1 and 5.508.1.2. 5.508.1.1 Chlorofluorocarbons (CFCs). Install HVAC, refrigeration and fire suppression equipment that do not contain CFCs. 5.508.1.2 Halons. Install HVAC, refrigeration and fire suppression equipment that do not contain Halons. 5.504.4.6 Resilient flooring systems. Where resilient flooring is installed, at least 80 percent of floor area receiving resilient flooring shall meet the requirements of the California Department of Public Health,"Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specifications 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx#material 5.504.4.6.1 Verification of compliance. Documentation shall be provided verifying that resilient flooring materials meet the pollutant emission limits. 5.504.4.7 Thermal insulation Comply with the requirements of the California Department of Public Health, "Standard Method of the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, "Version 1.2, January 1.2, January 2017 (Emission testing method for California Specification 01350). See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx#material 5.504.4.7.1 Verification of compliance. Documentation shall be provided verifying that thermal insulation materials meet the pollutant emission limits. 5.504.4.8 Acoustical ceiling and wall panels. Comply with the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, " Version 1.2, January 2017 (Emission testing method for California Specification 01350). See California Department of Public Health's website for certification programs and testing labs. 5.504.4.8.1 Verification of compliance. Documentation shall be provided verifying that acoustical finish materials meet the pollutant emission limits. 5.504.5.3 Filters. In mechanically ventilated buildings, provide regularly occupied areas of the building with air filtration media for outside and return air that provides at least a Minimum Efficiency Reporting Value (MERV) of 13. MERV 13 filters shall be installed prior to occupancy, and recommendations for maintenance with filters of the same value shall be included in the operation and maintenance manual. Exceptions: Existing mechanical equipment. 5.504.5.3.1 Labeling. Installed filters shall be clearly labeled by the manufacturer indicating the MERV rating. 5.504.7 ENVIRONMENTAL TOBACCO SMOKE (ETS) CONTROL. Where outdoor areas are provided for smoking, prohibit smoking within 25 feet of building entries, outdoor air intakes and operable windows and within the building as already prohibited by other laws or regulations; or as enforced by ordinances, regulations or policies of any city, county, city and county, California Community College, campus of the California State University, or campus of the University of California, whichever are more stringent. When ordinances, regulations or policies are not in place, post signage to inform building occupants of the prohibitions. 5.504.4.3.2 Verification. Verification of compliance with this section shall be provided at the request of the enforcing agency. Documentation may include, but is not limited to, the following: 1. Manufacturer's product specification 2. Field verification of on-site product containers 5.504.4.4 Carpet Systems. All carpet installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers." Version 1.2, January 2017 (Emission testing method for California Specifications 01350). See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx#material 5.504.4 FINISH MATERIAL POLLUTANT CONTROL. Finish materials shall comply with Sections 5.504.4.1 through 5.504.4.6. 5.504.4.1 Adhesives, sealants and caulks. Adhesives, sealants, and caulks used on the project shall meet the requirements of the following standards: 1. Adhesives, adhesive bonding primers, adhesive primers, sealants, sealant primers and caulks shall comply with local or regional air pollution control or air quality management district rules where applicable, or SCAQMD Rule 1168 VOC limits, as shown in Tables 5.504.4.1 and 5.504.4.2. Such products also shall comply with the Rule 1168 prohibition on the use of certain toxic compounds (chloroform, ethylene dichloride, methylene chloride, perchloroethylene and trichloroethylene), except for aerosol products as specified in subsection 2, below. 2. Aerosol adhesives, and smaller unit sizes of adhesives, and sealant or caulking compounds (in units of product, less packaging, which do not weigh more than one pound and do not consist of more than 16 fluid ounces) shall comply with statewide VOC standards and other requirements, including prohibitions on use of certain toxic compounds, of California Code of Regulations, Title 17, commencing with Section 94507. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. Y N/A Y N/A Y N/A Y N/ARESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY Y = YES N/A =NOT APPLICABLE RESPON. PARTY =RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 GENERAL. THIS CHAPTER CONTAINS SCOPING AND TECHNICAL REQUIREMENTS FOR ACCESSIBILITY TO SITES, FACILITIES, BUILDINGS, AND ELEMENTS BY INDIVIDUALS WITH DISABILITIES. THE REQUIREMENTS ARE TO BE APPLIED DURING THE DESIGN, CONSTRUCTION, ADDITIONS TO, AND ALTERATION OF SITES, FACILITIES, BUILDINGS, AND ELEMENTS TO THE EXTENT REQUIRED BY CHAPTER 1, SECTION 1.9. 11B-101.1 11B-101.1 PURPOSE 11B-101.1 RESERVED DIMENSIONS FOR ADULTS AND CHILDREN.THE TECHNICAL REQUIREMENTS ARE BASED ON ADULT DIMENSIONS AND ANTHROPOMETRICS. IN ADDITION, THIS CHAPTER INCLUDES TECHNICAL REQUIREMENTS BASED ON CHILDREN'S DIMENSIONS AND ANTHROPOMETRICS FOR DRINKING FOUNTAINS, WATER CLOSETS, TOILET COMPARTMENTS, LAVATORIES AND SINKS, DINING SURFACES, AND WORK SURFACES. 11B-102 EQUIVALENT FACILITATION.NOTHING IN THESE REQUIREMENTS PREVENTS THE USE OF DESIGNS, PRODUCTS, OR TECHNOLOGIES AS ALTERNATIVES TO THOSE PRESCRIBED, PROVIDED THEY RESULT IN SUBSTANTIALLY EQUIVALENT OR GREATER ACCESSIBILITY AND USABILITY. 11B-103 11B-104 CONVENTIONS. DIMENSIONS. DIMENSIONS THAT ARE NOT STATED AS "MAXIMUM" OR "MINIMUM" ARE ABSOLUTE.11B-104.1 CONSTRUCTION AND MANUFACTURING TOLERANCES. ALL DIMENSIONS ARE SUBJECT TO CONVENTIONAL INDUSTRY TOLERANCES EXCEPT WHERE THE REQUIREMENT IS STATED AS A RANGE WITH SPECIFIC MINIMUM AND MAXIMUM END POINTS. 11B-104.1.1 CALCULATION OF PERCENTAGES. WHERE THE REQUIRED NUMBER OF ELEMENTS OR FACILITIES TO BE PROVIDED IS DETERMINED BY CALCULATIONS OF RATIOS OR PERCENTAGES AND REMAINDERS OR FRACTIONS RESULT, THE NEXT GREATER WHOLE NUMBER OF SUCH ELEMENTS OR FACILITIES SHALL BE PROVIDED. WHERE THE DETERMINATION OF THE REQUIRED SIZE OR DIMENSION OF AN ELEMENT OR FACILITY INVOLVES RATIOS OR PERCENTAGES, ROUNDING DOWN FOR VALUES LESS THAN ONE HALF SHALL BE PERMITTED. 11B-104.2 FIGURES. UNLESS SPECIFICALLY STATED OTHERWISE, FIGURES ARE PROVIDED FOR INFORMATIONAL PURPOSES ONLY. 11B-104.3 11B-105 REFERENCED STANDARDS. GENERAL. SEE CALIFORNIA BUILDING CODE (CBC) CHAPTER 35.11B-105.1 11B-106 DEFINITIONS. GENERAL. FOR THE PURPOSE OF THIS CHAPTER, THE TERMS LISTED IN CBC SECTION 11 B-106.5 AND DEFINED IN CBC CHAPTER 2 HAVE THE INDICATED MEANING. 11B-106.1 TERMS DEFINED IN REFERENCED STANDARDS. TERMS NOT LISTED IN CBC SECTION LLB-106.5 AND NOT DEFINED IN CBC CHAPTER 2, SECTION 202, BUT SPECIFICALLY DEFINED IN A REFERENCED STANDARD, SHALL HAVE THE SPECIFIED MEANING FROM THE REFERENCED STANDARD UNLESS OTHERWISE STATED. 11B-106.2 UNDEFINED TERMS. THE MEANING OF TERMS NOT SPECIFICALLY LISTED IN CBC SECTION 11B-1 06.5, AND NOT DEFINED IN CBC CHAPTER 2, SECTION 202, OR IN REFERENCED STANDARDS SHALL BE AS DEFINED BY COLLEGIATE DICTIONARIES IN THE SENSE THAT THE CONTEXT IMPLIES. 11B-106.3 INTERCHANGEABILITY. SEE CBC CHAPTER 2, SECTION 201 .2.11B-106.4 11B-107 SPECIAL CONDITIONS APPEALS ACTION.SEE CBC CHAPTER 1, SECTION 1.9.1.5. MAINTENANCE OF ACCESSIBLE FEATURES.A PUBLIC ACCOMMODATION SHALL MAINTAIN IN OPERABLE WORKING CONDITION THOSE FEATURES OF FACILITIES AND EQUIPMENT THAT ARE REQUIRED TO BE ACCESSIBLE TO AND USEABLE BY PERSONS WITH DISABILITIES. ISOLATED OR TEMPORARY INTERRUPTIONS IN SERVICE OR ACCESSIBILITY DUE TO MAINTENANCE OR REPAIRS SHALL BE PERMITTED. 11B-108 DIVISION 1: APPLICATION AND ADMINISTRATION SCOPE. ALL AREAS OF NEWLY DESIGNED AND NEWLY CONSTRUCTED BUILDINGS AND FACILITIES AND ALTERED PORTIONS OF EXISTING BUILDINGS AND FACILITIES SHALL COMPLY WITH THESE REQUIREMENTS. 11B-201.1 11B-201 APPLICATION DIVISION 2: SCOPING REQUIREMENTS APPLICATION BASED ON BUILDING OR FACILITY USE. WHERE A SITE, BUILDING, FACILITY, ROOM, OR SPACE CONTAINS MORE THAN ONE USE, EACH PORTION SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS FOR THAT USE. 11B-201.2 TEMPORARY AND PERMANENT STRUCTURES. THESE REQUIREMENTS SHALL APPLY TO TEMPORARY AND PERMANENT BUILDINGS AND FACILITIES. 11B-201.3 CONSTRUCTION SUPPORT FACILITIES. THESE REQUIREMENTS SHALL APPLY TO TEMPORARY OR PERMANENT CONSTRUCTION SUPPORT FACILITIES FOR USES AND ACTIVITIES NOT DIRECTLY ASSOCIATED WITH THE ACTUAL PROCESSES OF CONSTRUCTION, INCLUDING BUT NOT LIMITED TO OFFICES, MEETING ROOMS, PLAN ROOMS, OTHER ADMINISTRATIVE OR SUPPORT FUNCTIONS. WHEN PROVIDED, TOILET AND BATHING FACILITIES SERVING CONSTRUCTION SUPPORT FACILITIES SHALL COMPLY WITH SECTION 11 B-213. WHEN TOILET AND BATHING FACILITIES SERVING CONSTRUCTION SUPPORT FACILITIES ARE PROVIDED BY PORTABLE UNITS, AT LEAST ONE OF EACH TYPE SHALL BE ACCESSIBLE AND CONNECTED TO THE CONSTRUCTION SUPPORT FACILITIES IT SERVES BY AN ACCESSIBLE ROUTE. 11B-201.4 EXCEPTION: DURING CONSTRUCTION AN ACCESSIBLE ROUTE SHALL NOT BE REQUIRED BETWEEN SITE ARRIVAL POINTS OR THE BOUNDARY OF THE AREA OF CONSTRUCTION AND THE ENTRANCE TO THE CONSTRUCTION SUPPORT FACILITIES IF THE ONLY MEANS OF ACCESS BETWEEN THEM IS A VEHICULAR WAY NOT PROVIDING PEDESTRIAN ACCESS. 11B-203 GENERAL EXCEPTIONS GENERAL. SITES, BUILDINGS, FACILITIES, AND ELEMENTS ARE EXEMPT FROM THESE REQUIREMENTS TO THE EXTENT SPECIFIED BY 11B-203 11B-203.1 CONSTRUCTION SITES. STRUCTURES AND SITES DIRECTLY ASSOCIATED WITH THE ACTUAL PROCESSES OF CONSTRUCTION, INCLUDING BUT NOT LIMITED TO, SCAFFOLDING, BRIDGING, MATERIALS HOISTS, MATERIALS STORAGE AND CONSTRUCTION TRAILERS SHALL NOT BE REQUIRED TO COMPLY WITH THESE REQUIREMENTS OR TO BE ON AN ACCESSIBLE ROUTE. PORTABLE TOILET UNITS PROVIDED FOR USE EXCLUSIVELY BY CONSTRUCTION PERSONNEL ON A CONSTRUCTION SITE SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-213 OR TO BE ON AN ACCESSIBLE ROUTE. 11B-203.2 RAISED AREAS. AREAS RAISED PRIMARILY FOR PURPOSES OF SECURITY, LIFE SAFETY, OR FIRE SAFETY, INCLUDING BUT NOT LIMITED TO, OBSERVATION OR LOOKOUT GALLERIES, PRISON GUARD TOWERS, FIRE TOWERS OR LIFE GUARD STANDS SHALL NOT BE REQUIRED TO COMPLY WITH THESE REQUIREMENTS OR TO BE ON AN ACCESSIBLE ROUTE. 11B-203.3 LIMITED ACCESS SPACES. SPACES NOT CUSTOMARILY OCCUPIED AND ACCESSED ONLY BY LADDERS, CATWALKS, CRAWL SPACES OR VERY NARROW PASSAGEWAYS SHALL NOT BE REQUIRED TO COMPLY WITH THESE REQUIREMENTS OR TO BE ON AN ACCESSIBLE ROUTE. 11B-203.4 MACHINERY SPACES. SPACES FREQUENTED ONLY BY SERVICE PERSONNEL FOR MAINTENANCE, REPAIR OR OCCASIONAL MONITORING OF EQUIPMENT SHALL NOT BE REQUIRED TO COMPLY WITH THESE REQUIREMENTS OR TO BE ON AN ACCESSIBLE ROUTE. MACHINERY SPACES INCLUDE, BUT ARE NOT LIMITED TO, ELEVATOR PITS OR ELEVATOR PENTHOUSES; MECHANICAL, ELECTRICAL OR COMMUNICATIONS EQUIPMENT ROOMS; PIPING OR EQUIPMENT CATWALKS; WATER OR SEWAGE TREATMENT PUMP ROOMS AND STATIONS; ELECTRIC SUBSTATIONS AND TRANSFORMER VAULTS; AND HIGHWAY AND TUNNEL UTILITY FACILITIES. 11B-203.5 RESIDENTIAL FACILITIES. IN PUBLIC HOUSING RESIDENTIAL FACILITIES, COMMON USE AREAS THAT DO NOT SERVE RESIDENTIAL DWELLING UNITS REQUIRED TO PROVIDE MOBILITY FEATURES COMPLYING WITH SECTIONS 11B-809.2 THROUGH 11B-809.4 AND ADAPTABLE FEATURES COMPLYING WITH CHAPTER 11A, DIVISION IV SHALL NOT BE REQUIRED TO COMPLY WITH THESE REQUIREMENTS OR TO BE ON AN ACCESSIBLE ROUTE. 11B-203.8 EMPLOYEE WORK AREAS. SPACES AND ELEMENTS WITHIN EMPLOYEE WORK AREAS SHALL ONLY BE REQUIRED TO COMPLY WITH SECTIONS 11B-206.2.8, 11B-207.1, AND 11B-215.3 AND SHALL BE DESIGNED AND CONSTRUCTED SO THAT INDIVIDUALS WITH DISABILITIES CAN APPROACH, ENTER, AND EXIT THE EMPLOYEE WORK AREA. 11B-203.9 11B-204 PROTRUDING OBJECTS GENERAL. PROTRUDING OBJECTS ON CIRCULATION PATHS SHALL COMPLY WITH SECTION 11B-301. 11B-204.1 1. 2. EXCEPTIONS: WITHIN AREAS OF SPORT ACTIVITY, PROTRUDING OBJECTS ON CIRCULATION PATHS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-301. WITHIN PLAY AREAS, PROTRUDING OBJECTS ON CIRCULATION PATHS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11 B-301 PROVIDED THAT GROUND LEVEL ACCESSIBLE ROUTES PROVIDE VERTICAL CLEARANCE IN COMPLIANCE WITH SECTION 11B-1008.2. 11B-205 OPERABLE PARTS GENERAL. OPERABLE PARTS ON ACCESSIBLE ELEMENTS, ACCESSIBLE ROUTES, AND IN ACCESSIBLE ROOMS AND SPACES SHALL COMPLY WITH SECTION 11B-309. 11B-205.1 1. 2. 3. 4. 5. 6. 7. 8. EXCEPTIONS: OPERABLE PARTS THAT ARE INTENDED FOR USE ONLY BY SERVICE OR MAINTENANCE PERSONNEL SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-309. E ELECTRICAL OR COMMUNICATION RECEPTACLES SERVING A DEDICATED USE SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-309. RESERVED. FLOOR ELECTRICAL RECEPTACLES SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-309. HVAC DIFFUSERS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-309. EXCEPT FOR LIGHT SWITCHES, WHERE REDUNDANT CONTROLS ARE PROVIDED FOR A SINGLE ELEMENT, ONE CONTROL IN EACH SPACE SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-309. CLEATS AND OTHER BOAT SECUREMENT DEVICES SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-309.3. EXERCISE MACHINES AND EXERCISE EQUIPMENT SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-309. 11B-206 ACCESSIBLE ROUTES 1. 2. 3. EXCEPTIONS: RESERVED. AN ACCESSIBLE ROUTE SHALL NOT BE REQUIRED BETWEEN SITE ARRIVAL POINTS AND THE BUILDING OR FACILITY ENTRANCE IF THE ONLY MEANS OF ACCESS BETWEEN THEM IS A VEHICULAR WAY NOT PROVIDING PEDESTRIAN ACCESS. GENERAL CIRCULATION PATHS SHALL BE PERMITTED WHEN LOCATED IN CLOSE PROXIMITY TO AN ACCESSIBLE ROUTE. GENERAL. ACCESSIBLE ROUTES SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 11B-206 AND SHALL COMPLY WITH DIVISION 4. 11B-206.1 GENERAL. ACCESSIBLE ROUTES SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 11B-206 AND SHALL COMPLY WITH DIVISION 4. 11B-206.2 SITE ARRIVAL POINTS. AT LEAST ONE ACCESSIBLE ROUTE SHALL BE PROVIDED WITHIN THE SITE FROM ACCESSIBLE PARKING SPACES AND ACCESSIBLE PASSENGER DROP-OFF AND LOADING ZONES; PUBLIC STREETS AND SIDEWALKS; AND PUBLIC TRANSPORTATION STOPS TO THE ACCESSIBLE BUILDING OR FACILITY ENTRANCE THEY SERVE. WHERE MORE THAN ONE ROUTE IS PROVIDED, ALL ROUTES MUST BE ACCESSIBLE. 11B-206.2.1 WITHIN A SITE. AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDINGS, ACCESSIBLE FACILITIES, ACCESSIBLE ELEMENTS, AND ACCESSIBLE SPACES THAT ARE ON THE SAME SITE. 11B-206.2.2 EXCEPTIONS: AN ACCESSIBLE ROUTE SHALL NOT BE REQUIRED BETWEEN ACCESSIBLE BUILDINGS, ACCESSIBLE FACILITIES, ACCESSIBLE ELEMENTS, AND ACCESSIBLE SPACES IF THE ONLY MEANS OF ACCESS BETWEEN THEM IS A VEHICULAR WAY NOT PROVIDING PEDESTRIAN ACCESS. MULTISTORY BUILDINGS AND FACILITIES. AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT EACH STORY AND MEZZANINE IN MULTISTORY BUILDINGS AND FACILITIES. 11B-206.2.3 1. 2. 3. 4. 5. 6. 7. EXCEPTIONS: THE FOLLOWING TYPES OF PRIVATELY FUNDED MULTI-STORY BUILDINGS DO NOT REQUIRE A RAMP OR ELEVATOR ABOVE AND BELOW THE FIRST FLOOR: 1.1. MULTISTORIED OFFICE BUILDINGS (OTHER THAN THE PROFESSIONAL OFFICE OF A HEALTH CARE PROVIDER) AND PASSENGER VEHICLE SERVICE STATIONS LESS THAN THREE STORIES HIGH OR LESS THAN 3,000 SQUARE FEET (279 M2) PER STORY. 1.2. ANY OTHER PRIVATELY FUNDED MULTISTORIED BUILDING THAT IS NOT A SHOPPING CENTER, SHOPPING MALL OR THE PROFESSIONAL OFFICE OF A HEALTH CARE PROVIDER, OR A TERMINAL, DEPOT OR OTHER STATION USED FOR SPECIFIED PUBLIC TRANSPORTATION, OR AN AIRPORT PASSENGER TERMINAL AND THAT IS LESS THAN THREE STORIES HIGH OR LESS THAN 3,000 SQUARE FEET (279 M2) PER STORY IF A REASONABLE PORTION OF ALL FACILITIES AND ACCOMMODATIONS NORMALLY SOUGHT AND USED BY THE PUBLIC IN SUCH A BUILDING ARE ACCESSIBLE TO AND USABLE BY PERSONS WITH DISABILITIES. RESERVED. IN RESIDENTIAL FACILITIES, AN ACCESSIBLE ROUTE SHALL NOT BE REQUIRED TO CONNECT STORIES WHERE RESIDENTIAL DWELLING UNITS WITH MOBILITY FEATURES REQUIRED TO COMPLY WITH SECTIONS 11B-809.2 THROUGH 11B-809.4, RESIDENTIAL DWELLING UNITS WITH ADAPTABLE FEATURES COMPLYING WITH CHAPTER 11A, DIVISION IV, ALL COMMON USE AREAS SERVING RESIDENTIAL DWELLING UNITS WITH MOBILITY FEATURES REQUIRED TO COMPLY WITH SECTIONS 11B-809.2 THROUGH 11B-809.4, ALL COMMON USE AREAS SERVING RESIDENTIAL DWELLING UNITS WITH ADAPTABLE FEATURES COMPLYING WITH CHAPTER 11A, DIVISION IV, AND PUBLIC USE AREAS 6. SINE ARIVRI NTGR ARFEFSICID CENTIAL DWELLING UNITS ARE ON AN ACCESSIBLE ROUTE. IN RESIDENTIAL FACILITIES, AN ACCESSIBLE ROUTE SHALL NOT BE REQUIRED TO CONNECT STORIES WHERE RESIDENTIAL DWELLING UNITS WITH MOBILITY FEATURES REQUIRED TO COMPLY WITH SECTIONS 11B-809.2 THROUGH 11B-809.4, RESIDENTIAL DWELLING UNITS WITH ADAPTABLE FEATURES COMPLYING WITH SECTIONS 11B-809.6 THROUGH 11B-809.12, ALL COMMON USE AREAS SERVING RESIDENTIAL DWELLING UNITS WITH MOBILITY FEATURES REQUIRED TO COMPLY WITH SECTIONS 11B-809.2 THROUGH 11B-809.4, ALL COMMON USE AREAS SERVING RESIDENTIAL DWELLING UNITS WITH ADAPTABLE FEATURES COMPLYING WITH SECTIONS 11B-809.6 THROUGH 11B-809.12, AND PUBLIC USE AREAS SERVING RESIDENTIAL DWELLING UNITS ARE ON AN ACCESSIBLE ROUTE. WITHIN MULTISTORY TRANSIENT LODGING GUEST ROOMS WITH MOBILITY FEATURES REQUIRED TO COMPLY WITH SECTION 11B-806.2, AN ACCESSIBLE ROUTE SHALL NOT BE REQUIRED TO CONNECT STORIES PROVIDED THAT SPACES COMPLYING WITH SECTION 11B-806.2 ARE ON AN ACCESSIBLE ROUTE AND SLEEPING ACCOMMODATIONS FOR TWO PERSONS MINIMUM ARE PROVIDED ON A STORY SERVED BY AN ACCESSIBLE ROUTE. IN AIR TRAFFIC CONTROL TOWERS, AN ACCESSIBLE ROUTE SHALL NOT BE REQUIRED TO SERVE THE CAB AND THE EQUIPMENT AREAS ON THE FLOOR IMMEDIATELY BELOW THE CAB. RESERVED PEDESTRIAN STREET CROSSINGS. WHERE WALKS OR SIDEWALKS ARE PROVIDED, A CURB RAMP, BLENDED TRANSITION, OR A COMBINATION OF CURB RAMPS AND BLENDED TRANSITIONS COMPLYING WITH SECTION 11B-406 SHALL CONNECT THE WALKS OR SIDEWALKS AT EACH PEDESTRIAN STREET CROSSING. THE CURB RAMP (EXCLUDING ANY FLARED SIDES) OR BLENDED TRANSITION SHALL BE CONTAINED WHOLLY WITHIN THE WIDTH OF THE PEDESTRIAN STREET CROSSING SERVED. 11B-206.2.19 EXCEPTIONS:COMPLIANCE WITH SECTION 11B-206.2.19 SHALL NOT BE REQUIRED WHERE PEDESTRIAN CROSSING IS PROHIBITED BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. LOCATION. ACCESSIBLE ROUTES SHALL COINCIDE WITH OR BE LOCATED IN THE SAME AREA AS GENERAL CIRCULATION PATHS. WHERE CIRCULATION PATHS ARE INTERIOR, REQUIRED ACCESSIBLE ROUTES SHALL ALSO BE INTERIOR. AN ACCESSIBLE ROUTE SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, RESTROOMS, CLOSETS OR OTHER SPACES USED FOR SIMILAR PURPOSES, EXCEPT AS PERMITTED BY CHAPTER 10. 11B-206.3 ENTRANCES. ENTRANCES SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 11B-206.4. ENTRANCE DOORS, DOORWAYS, AND GATES SHALL COMPLY WITH SECTION 11B-404 AND SHALL BE ON AN ACCESSIBLE ROUTE COMPLYING WITH SECTION 11B-402. 11B-206.4 1. 2. EXCEPTIONS: RESERVED RESERVED ENTRANCES AND EXTERIOR GROUND FLOOR EXITS. ALL ENTRANCES AND EXTERIOR GROUNDFLOOR EXITS TO BUILDINGS AND FACILITIES SHALL COMPLY WITH SECTION 11B-404. 11B-206.4.1 1. 2. EXCEPTIONS: EXTERIOR GROUND FLOOR EXITS SERVING SMOKE-PROOF ENCLOSURES, STAIRWELLS, AND EXIT DOORS SERVING STAIRS ONLY SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-404. EXITS IN EXCESS OF THOSE REQUIRED BY CHAPTER 10, AND WHICH ARE MORE THAN 24 INCHES (610 mm) ABOVE GRADE SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-404. DIRECTIONAL SIGNS SHALL COMPLY WITH CHAPTER 10, SECTION 1009.10. TENANT SPACES. ALL ENTRANCES TO EACH TENANCY IN A FACILITY SHALL COMPLY WITH SECTION 11B-404. 11B-206.4.5 EXCEPTION: SELF-SERVICE STORAGE FACILITIES NOT REQUIRED TO COMPLY WITH SECTION 11B-225.3 SHALL NOT BE REQUIRED TO BE ON AN ACCESSIBLE ROUTE. RESIDENTIAL DWELLING UNIT PRIMARY ENTRANCE. IN RESIDENTIAL DWELLING UNITS, AT LEAST ONE PRIMARY ENTRANCE SHALL COMPLY WITH SECTION 11B-404. THE PRIMARY ENTRANCE TO A RESIDENTIAL DWELLING UNIT SHALL NOT BE TO A BEDROOM. 11B-206.4.6 RESTRICTED ENTRANCES. WHERE RESTRICTED ENTRANCES ARE PROVIDED TO A BUILDING OR FACILITY, ALL RESTRICTED ENTRANCES TO THE BUILDING OR FACILITY SHALL COMPLY WITH SECTION 11B-404. 11B-206.4.7 SERVICE ENTRANCES. IF A SERVICE ENTRANCE IS THE ONLY ENTRANCE TO A BUILDING OR TO A TENANCY IN A FACILITY, THAT ENTRANCE SHALL COMPLY WITH SECTION 11B-404. IN EXISTING BUILDINGS AND FACILITIES, A SERVICE ENTRANCE SHALL NOT BE THE SOLE ACCESSIBLE ENTRANCE UNLESS IT IS THE ONLY ENTRANCE TO A BUILDING OR FACILITY. 11B-206.4.8 DOORS, DOORWAYS, AND GATES. DOORS, DOORWAYS AND GATES PROVIDING USER PASSAGE SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 11B-206.5. 11B-206.5 ENTRANCES. EACH ENTRANCE TO A BUILDING OR FACILITY REQUIRED TO COMPLY WITH SECTION 11B-206.4 SHALL COMPLY WITH SECTION 11B-404. 11B-206.5.1 ROOMS AND SPACES. WITHIN A BUILDING OR FACILITY, EVERY DOOR, DOORWAY OR GATE SERVING ROOMS AND SPACES COMPLYING WITH THIS CHAPTER SHALL COMPLY WITH SECTION 11B-404. 11B-206.5.2 RESIDENTIAL DWELLING UNITS. IN RESIDENTIAL DWELLING UNITS REQUIRED TO PROVIDE MOBILITY FEATURES COMPLYING WITH SECTIONS 11B-809.2 THROUGH 11B-809.4, ALL DOORS AND DOORWAYS PROVIDING USER PASSAGE SHALL COMPLY WITH SECTION 11B-404. 11B-206.5.4 ELEVATORS. ELEVATORS PROVIDED FOR PASSENGERS SHALL COMPLY WITH SECTION 11B-407. WHERE MULTIPLE ELEVATORS ARE PROVIDED, EACH ELEVATOR SHALL COMPLY WITH SECTION 11B-407. 11B-206.6 1. 2. 3. EXCEPTIONS: IN A BUILDING OR FACILITY PERMITTED TO USE THE EXCEPTIONS TO SECTION 11B-206.2.3 OR PERMITTED BY SECTION 11B-206.7 TO USE A PLATFORM LIFT, ELEVATORS COMPLYING WITH SECTION 11B-408 SHALL BE PERMITTED. ELEVATORS COMPLYING WITH SECTION 11B-408 OR 11B-409 SHALL BE PERMITTED IN MULTISTORY RESIDENTIAL DWELLING UNITS. ELEVATORS PROVIDED AS A MEANS OF ACCESS WITHIN A PRIVATE RESIDENCE SHALL BE INSTALLED SO THAT THEY ARE NOT ACCESSIBLE TO THE GENERAL PUBLIC OR TO OTHER OCCUPANTS OF THE BUILDING. DESTINATION-ORIENTED ELEVATORS COMPLYING WITH SECTION 11B-411 SHALL BE PERMITTED. PLATFORM LIFTS. PLATFORM LIFTS SHALL COMPLY WITH SECTION 11B-410. PLATFORM LIFTS SHALL BE PERMITTED AS A COMPONENT OF AN ACCESSIBLE ROUTE IN NEW CONSTRUCTION IN ACCORDANCE WITH SECTION 11B-206.7. PLATFORM LIFTS SHALL BE PERMITTED AS A COMPONENT OF AN ACCESSIBLE ROUTE IN AN EXISTING BUILDING OR FACILITY. 11B-206.7 WHEELCHAIR SPACES. PLATFORM LIFTS SHALL BE PERMITTED TO PROVIDE AN ACCESSIBLE ROUTE TO COMPLY WITH THE WHEELCHAIR SPACE DISPERSION AND LINE-OF-SIGHT REQUIREMENTS OF SECTIONS 11B-221 AND 11B-802. 11B-206.7.2 INCIDENTAL SPACES. PLATFORM LIFTS SHALL BE PERMITTED TO PROVIDE AN ACCESSIBLE ROUTE TO INCIDENTAL SPACES WHICH ARE NOT PUBLIC USE SPACES AND WHICH ARE OCCUPIED BY FIVE PERSONS MAXIMUM. 11B-206.7.3 EXISTING SITE CONSTRAINTS. PLATFORM LIFTS SHALL BE PERMITTED WHERE EXISTING EXTERIOR SITE CONSTRAINTS MAKE USE OF A RAMP OR ELEVATOR INFEASIBLE. 11B-206.7.5 GUEST ROOMS AND RESIDENTIAL DWELLING UNITS. PLATFORM LIFTS SHALL BE PERMITTED TO CONNECT LEVELS WITHIN TRANSIENT LODGING GUEST ROOMS REQUIRED TO PROVIDE MOBILITY FEATURES COMPLYING WITH SECTION 11B-806.2 OR RESIDENTIAL DWELLING UNITS REQUIRED TO PROVIDE MOBILITY FEATURES COMPLYING WITH SECTIONS 11B-809.2 THROUGH 11B-809.4 AND ADAPTABLE FEATURES COMPLYING WITH CHAPTER 11A, DIVISION IV. 11B-206.7.6 STAIRS AND ESCALATORS IN EXISTING BUILDINGS. IN ALTERATIONS AND ADDITIONS, WHERE AN ESCALATOR OR STAIR IS PROVIDED WHERE NONE EXISTED PREVIOUSLY AND MAJOR STRUCTURAL MODIFICATIONS ARE NECESSARY FOR THE INSTALLATION, AN ACCESSIBLE ROUTE SHALL BE PROVIDED BETWEEN THE LEVELS SERVED BY THE ESCALATOR OR STAIR UNLESS EXEMPTED BY SECTION 11B-206.2.3 EXCEPTIONS 1 THROUGH 7. 11B-206.2.3.1 DISTANCE TO ELEVATORS. IN NEW CONSTRUCTION OF BUILDINGS WHERE ELEVATORS ARE REQUIRED BY SECTION 11B-206.2.3, AND WHICH EXCEED 10,000 SQUARE FEET (929 M2) ON ANY FLOOR, AN ACCESSIBLE MEANS OF VERTICAL ACCESS VIA RAMP, ELEVATOR OR LIFT SHALL BE PROVIDED WITHIN 200 FEET (60,960 mm) OF TRAVEL OF EACH STAIR AND EACH ESCALATOR. IN EXISTING BUILDINGS THAT EXCEED 10,000 SQUARE FEET (929 M2) ON ANY FLOOR AND IN WHICH ELEVATORS ARE REQUIRED BY SECTION 11B-206.2.3, WHENEVER A NEWLY CONSTRUCTED MEANS OF VERTICAL ACCESS IS PROVIDED VIA STAIRS OR AN ESCALATOR, AN ACCESSIBLE MEANS OF VERTICAL ACCESS VIA RAMP, ELEVATOR OR LIFT SHALL BE PROVIDED WITHIN 200 FEET (60,960 mm) OF TRAVEL OF EACH NEW STAIR OR ESCALATOR. 11B-206.2.3.2 EXCEPTIONS:STAIRS USED SOLELY FOR EMERGENCY EGRESS. SPACES AND ELEMENTS. AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDING OR FACILITY ENTRANCES WITH ALL ACCESSIBLE SPACES AND ELEMENTS WITHIN THE BUILDING OR FACILITY, INCLUDING MEZZANINES, WHICH ARE OTHERWISE CONNECTED BY A CIRCULATION PATH UNLESS EXEMPTED BY SECTION 11B-206.2.3 EXCEPTIONS 1 THROUGH 7. 11B-206.2.4 1. 2. 3. EXCEPTIONS: RESERVED. IN ASSEMBLY AREAS WITH FIXED SEATING REQUIRED TO COMPLY WITH SECTION 11B-221, AN ACCESSIBLE ROUTE SHALL NOT BE REQUIRED TO SERVE FIXED SEATING WHERE WHEELCHAIR SPACES REQUIRED TO BE ON AN ACCESSIBLE ROUTE ARE NOT PROVIDED. RESERVED. EMPLOYEE WORK AREAS. COMMON USE CIRCULATION PATHS WITHIN EMPLOYEE WORK AREAS SHALL COMPLY WITH SECTION 11B-402. 11B-206.2.8 1. 2. 3. EXCEPTIONS: RESERVED. COMMON USE CIRCULATION PATHS LOCATED WITHIN EMPLOYEE WORK AREAS THAT ARE AN INTEGRAL COMPONENT OF WORK AREA EQUIPMENT SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-402.RESERVED. COMMON USE CIRCULATION PATHS LOCATED WITHIN EXTERIOR EMPLOYEE WORK AREAS THAT ARE FULLY EXPOSED TO THE WEATHER SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-402. COURT SPORTS. IN COURT SPORTS, AT LEAST ONE ACCESSIBLE ROUTE SHALL DIRECTLY CONNECT BOTH SIDES OF THE COURT. 11B-206.2.12 EXERCISE MACHINES AND EQUIPMENT. EXERCISE MACHINES AND EQUIPMENT REQUIRED TO COMPLY WITH 11B-236 SHALL BE ON AN ACCESSIBLE ROUTE. 11B-206.2.13 11B-207 ACCESSIBLE MEANS OF EGRESS GENERAL. MEANS OF EGRESS SHALL COMPLY WITH CHAPTER 10, SECTION 1009.11B-207.1 1. 2. 3. EXCEPTIONS: WHERE MEANS OF EGRESS ARE PERMITTED BY LOCAL BUILDING OR LIFE SAFETY CODES TO SHARE A COMMON PATH OF EGRESS TRAVEL, ACCESSIBLE MEANS OF EGRESS SHALL BE PERMITTED TO SHARE A COMMON PATH OF EGRESS TRAVEL. AREAS OF REFUGE SHALL NOT BE REQUIRED IN DETENTION AND CORRECTIONAL FACILITIES. ACCESSIBLE MEANS OF EGRESS ARE NOT REQUIRED TO BE PROVIDED IN EXISTING BUILDINGS. PLATFORM LIFTS. STANDBY POWER SHALL BE PROVIDED FOR PLATFORM LIFTS PERMITTED BY CHAPTER 10, SECTION 1009.5 TO SERVE AS A PART OF AN ACCESSIBLE MEANS OF EGRESS. TO ENSURE CONTINUED OPERATION IN CASE OF PRIMARY POWER LOSS, PLATFORM LIFTS SHALL BE PROVIDED WITH STANDBY POWER OR WITH SELF-RECHARGEABLE BATTERY POWER THAT PROVIDES SUFFICIENT POWER TO OPERATE ALL PLATFORM LIFT FUNCTIONS FOR A MINIMUM OF FIVE UPWARD AND DOWNWARD TRIPS. 11B-207.2 11B-208 PARKING SPACES GENERAL. WHERE PARKING SPACES ARE PROVIDED, PARKING SPACES SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 11B-208. FOR THE PURPOSES OF THIS SECTION, ELECTRIC VEHICLE CHARGING STATIONS ARE NOT PARKING SPACES; SEE SECTION 11B-228. 11B-208.1 EXCEPTIONS:PARKING SPACES USED EXCLUSIVELY FOR BUSES, TRUCKS, OTHER DELIVERY VEHICLES, OR VEHICULAR IMPOUND SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-208 PROVIDED THAT LOTS ACCESSED BY THE PUBLIC ARE PROVIDED WITH A PASSENGER DROP-OFF AND LOADING ZONE COMPLYING WITH SECTION 11B-503. MINIMUM NUMBER. PARKING SPACES COMPLYING WITH SECTION 11B-502 SHALL BE PROVIDED IN ACCORDANCE WITH TABLE 11B-208.2 EXCEPT AS REQUIRED BY SECTIONS 11B-208.2.1, 11B-208.2.2, AND 11B-208.2.3. WHERE MORE THAN ONE PARKING FACILITY IS PROVIDED ON A SITE, THE NUMBER OF ACCESSIBLE SPACES PROVIDED ON THE SITE SHALL BE CALCULATED ACCORDING TO THE NUMBER OF SPACES REQUIRED FOR EACH PARKING FACILITY. 11B-208.2 TABLE 11B-208.2 PARKING SPACES TOTAL NUMBER OF PARKING SPACES PROVIDED IN PARKING MINIMUM NUMBER OF REQUIRED ACCESSIBLE PARKING SPACES 1 TO 25 1 26 TO 50 2 51 TO 75 3 76 TO 100 4 101 TO 150 5 151 TO 200 6 201 TO 300 7 301 TO 400 8 401 TO 500 9 501 TO 1,000 2 PERCENT OF TOTAL 1001 AND OVER 20, PLUS 1 FOR EACH 100, OR FRACTION THEREOF, OVER 1,000 RESIDENTIAL FACILITIES. PARKING SPACES PROVIDED TO SERVE RESIDENTIAL FACILITIES SHALL COMPLY WITH SECTION 11B-208.2.3. 11B-208.2.3 PARKING FOR RESIDENTS. WHERE AT LEAST ONE PARKING SPACE IS PROVIDED FOR EACH RESIDENTIAL DWELLING UNIT, AT LEAST ONE PARKING SPACE COMPLYING WITH SECTION 11B-502 SHALL BE PROVIDED FOR EACH RESIDENTIAL DWELLING UNIT REQUIRED TO PROVIDE MOBILITY FEATURES COMPLYING WITH SECTIONS 11B-809.2 THROUGH 11B-809.4. WHERE FEWER THAN ONE PARKING SPACE IS PROVIDED FOR EACH RESIDENTIAL DWELLING UNIT, PARKING SPACES COMPLYING WITH SECTION 11B-502 SHALL BE PROVIDED IN ACCORDANCE WITH TABLE 11B-208.2. 11B-208.2.3.1 ADDITIONAL PARKING SPACES FOR RESIDENTS. WHERE THE TOTAL NUMBER OF PARKING SPACES PROVIDED FOR EACH RESIDENTIAL DWELLING UNIT EXCEEDS ONE PARKING SPACE PER RESIDENTIAL DWELLING UNIT, 2 PERCENT, BUT NO FEWER THAN ONE SPACE, OF ALL THE PARKING SPACES NOT COVERED BY SECTION 11B-208.2.3.1 SHALL COMPLY WITH SECTION 11B-502. 11B-208.2.3.2 PARKING FOR GUESTS, EMPLOYEES, AND OTHER NON-RESIDENTS. WHERE PARKING SPACES ARE PROVIDED FOR PERSONS OTHER THAN RESIDENTS, PARKING SHALL BE PROVIDED IN ACCORDANCE WITH TABLE 11B-208.2. NOTE: WHEN ASSIGNED PARKING IS PROVIDED, CHAPTER 11A INDICATES DESIGNATED ACCESSIBLE PARKING FOR THE ADAPTABLE RESIDENTIAL DWELLING UNITS SHALL BE PROVIDED ON REQUESTS OF RESIDENTS WITH DISABILITIES ON THE SAME TERMS AND WITH THE FULL RANGE OF CHOICES (E.G., OFF-STREET PARKING, CARPORT OR GARAGE THAT ARE AVAILABLE TO OTHER RESIDENTS. 11B-208.2.3.3 VAN PARKING SPACES. FOR EVERY SIX OR FRACTION OF SIX PARKING SPACES REQUIRED BY SECTION 11B-208.2 TO COMPLY WITH SECTION 11B-502, AT LEAST ONE SHALL BE A VAN PARKING SPACE COMPLYING WITH SECTION 11B-502. 11B-208.2.4 LOCATION. PARKING FACILITIES SHALL COMPLY WITH SECTION 11B-208.3.11B-208.3 GENERAL. PARKING SPACES COMPLYING WITH SECTION 11B-502 THAT SERVE A PARTICULAR BUILDING OR FACILITY SHALL BE LOCATED ON THE SHORTEST ACCESSIBLE ROUTE FROM PARKING TO AN ENTRANCE COMPLYING WITH SECTION 11B-206.4. WHERE PARKING SERVES MORE THAN ONE ACCESSIBLE ENTRANCE, PARKING SPACES COMPLYING WITH SECTION 11B-502 SHALL BE DISPERSED AND LOCATED ON THE SHORTEST ACCESSIBLE ROUTE TO THE ACCESSIBLE ENTRANCES. IN PARKING FACILITIES THAT DO NOT SERVE A PARTICULAR BUILDING OR FACILITY, PARKING SPACES COMPLYING WITH SECTION 11B-502 SHALL BE LOCATED ON THE SHORTEST ACCESSIBLE ROUTE TO AN ACCESSIBLE PEDESTRIAN ENTRANCE OF THE PARKING FACILITY. 11B-208.3.1 1. 2. EXCEPTIONS: ALL VAN PARKING SPACES SHALL BE PERMITTED TO BE GROUPED ON ONE LEVEL WITHIN A MULTISTORY PARKING FACILITY. PARKING SPACES SHALL BE PERMITTED TO BE LOCATED IN DIFFERENT PARKING FACILITIES IF SUBSTANTIALLY EQUIVALENT OR GREATER ACCESSIBILITY IS PROVIDED IN TERMS OF DISTANCE FROM AN ACCESSIBLE ENTRANCE OR ENTRANCES, PARKING FEE, AND USER CONVENIENCE. RESIDENTIAL FACILITIES. IN RESIDENTIAL FACILITIES CONTAINING RESIDENTIAL DWELLING UNITS REQUIRED TO PROVIDE MOBILITY FEATURES COMPLYING WITH SECTIONS 11B-809.2 THROUGH 11B-809.4, AND ADAPTABLE FEATURES COMPLYING WITH CHAPTER 11A, DIVISION IV, PARKING SPACES PROVIDED IN ACCORDANCE WITH SECTION 11B-208.2.3.1 SHALL BE LOCATED ON THE SHORTEST ACCESSIBLE ROUTE TO THE RESIDENTIAL DWELLING UNIT ENTRANCE THEY SERVE. SPACES PROVIDED IN ACCORDANCE WITH SECTION 11B-208.2.3.2 SHALL BE DISPERSED THROUGHOUT ALL TYPES OF PARKING PROVIDED FOR THE RESIDENTIAL DWELLING UNITS. 11B-208.3.2 EXCEPTIONS:PARKING SPACES PROVIDED IN ACCORDANCE WITH SECTION 11B-208.2.3.2 SHALL NOT BE REQUIRED TO BE DISPERSED THROUGHOUT ALL TYPES OF PARKING IF SUBSTANTIALLY EQUIVALENT OR GREATER ACCESSIBILITY IS PROVIDED IN TERMS OF DISTANCE FROM AN ACCESSIBLE ENTRANCE, PARKING FEE, AND USER CONVENIENCE. PRIVATE GARAGES ACCESSORY TO RESIDENTIAL DWELLING UNITS. PRIVATE GARAGES ACCESSORY TO RESIDENTIAL DWELLING UNITS SHALL COMPLY WITH SECTION 11B-208.3. PRIVATE GARAGES INCLUDE INDIVIDUAL GARAGES AND MULTIPLE INDIVIDUAL GARAGES GROUPED TOGETHER. 11B-208.3.3 DETACHED PRIVATE GARAGES ACCESSORY TO RESIDENTIAL DWELLING UNITS SHALL BE ACCESSIBLE AS REQUIRED BY SECTION 11B-208.3. 11B-208.3.3.1 ATTACHED PRIVATE GARAGES DIRECTLY SERVING A SINGLE RESIDENTIAL DWELLING UNIT SHALL PROVIDE AT LEAST ONE OF THE FOLLOWING OPTIONS: 11B-208.3.3.2 1. 2. 3. A DOOR LEADING DIRECTLY FROM THE RESIDENTIAL DWELLING UNIT WHICH IMMEDIATELY ENTERS THE GARAGE. AN ACCESSIBLE ROUTE FROM THE RESIDENTIAL DWELLING UNIT TO AN EXTERIOR DOOR ENTERING THE GARAGE. AN ACCESSIBLE ROUTE FROM THE RESIDENTIAL DWELLING UNIT'S PRIMARY ENTRY DOOR TO THE VEHICULAR ENTRANCE AT THE GARAGE. 11B-208 PASSENGER LOADING ZONES AND BUS STOPS GENERAL. PASSENGER DROP-OFF AND LOADING ZONES SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 11B-209. 11B-209.1 TYPE. WHERE PROVIDED, PASSENGER DROP-OFF AND LOADING ZONES SHALL COMPLY WITH SECTION 11B-209.2. 11B-209.2 PASSENGER DROP-OFF AND LOADING ZONES. PASSENGER DROP-OFF AND LOADING ZONES, EXCEPT THOSE REQUIRED TO COMPLY WITH SECTIONS 11B-209.2.2 AND 11B-209.2.3, SHALL PROVIDE AT LEAST ONE PASSENGER DROP-OFF AND LOADING ZONE COMPLYING WITH SECTION 11B-503 IN EVERY CONTINUOUS 100 LINEAR FEET (30480 mm) OF DROP-OFF AND LOADING ZONE SPACE, OR FRACTION THEREOF. 11B-209.2.1 BUS LOADING ZONES. IN BUS LOADING ZONES RESTRICTED TO USE BY DESIGNATED OR SPECIFIED PUBLIC TRANSPORTATION VEHICLES, EACH BUS BAY, BUS STOP, OR OTHER AREA DESIGNATED FOR LIFT OR RAMP DEPLOYMENT SHALL COMPLY WITH SECTION 11B-810.2. 11B-209.2.2 ON-STREET BUS STOPS. ON-STREET BUS STOPS SHALL COMPLY WITH SECTION 11B-810.2 TO THE MAXIMUM EXTENT PRACTICABLE. 11B-209.2.3 11B-208 STAIRWAYS GENERAL. INTERIOR AND EXTERIOR STAIRS SHALL COMPLY WITH SECTION 11B-504.11B-210.1 1. 2. 3. 4. EXCEPTIONS: IN DETENTION AND CORRECTIONAL FACILITIES, STAIRS THAT ARE NOT LOCATED IN PUBLIC USE AREAS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-504. IN ALTERATIONS, STAIRS BETWEEN LEVELS THAT ARE CONNECTED BY AN ACCESSIBLE ROUTE SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-504, EXCEPT THAT STRIPING COMPLYING WITH SECTION 11B-504.4.1 AND HANDRAILS COMPLYING WITH SECTION 11B-505 SHALL BE PROVIDED WHEN THE STAIRS ARE ALTERED. IN ASSEMBLY AREAS, AISLE STAIRS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-504 EXCEPT THAT STRIPING COMPLYING WITH SECTION 11B-504.4.1 SHALL BE PROVIDED. STAIRS THAT CONNECT PLAY COMPONENTS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-504 EXCEPT THATSTRIPING COMPLYING WITH SECTION 11B-504.4.1 SHALL BE PROVIDED. 11B-211 DRINKING FOUNTAINS GENERAL. WHERE DRINKING FOUNTAINS ARE PROVIDED ON AN EXTERIOR SITE, ON A FLOOR, OR WITHIN A SECURED AREA THEY SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 11B-211. 11B-211.1 MINIMUM NUMBER. NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. WHEN PROVIDED, ONE DRINKING FOUNTAIN SHALL COMPLY WITH SECTIONS 11B-602.1 THROUGH 11B-602.6, 11B-602.8 AND 11B-602.9 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH SECTIONS 11B-602.7 AND 11B-602.9. 11B-211.2 EXCEPTIONS:WHERE A SINGLE DRINKING FOUNTAIN COMPLIES WITH SECTIONS 11B-602.1 THROUGH 11B-602.9, IT SHALL BE PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING FOUNTAINS. MORE THAN MINIMUM NUMBER. WHERE MORE THAN THE MINIMUM NUMBER OF DRINKING FOUNTAINS SPECIFIED IN SECTION 11B-211.2 ARE PROVIDED, 50 PERCENT OF THE TOTAL NUMBER OF DRINKING FOUNTAINS PROVIDED SHALL COMPLY WITH SECTIONS 11B-602.1 THROUGH 11B-602.6, 11B-602.8 AND 11B-602.9, AND 50 PERCENT OF THE TOTAL NUMBER OF DRINKING FOUNTAINS PROVIDED SHALL COMPLY WITH SECTIONS 11B-602.7 AND 11B-602.9. 11B-211.3 EXCEPTIONS:WHERE 50 PERCENT OF THE DRINKING FOUNTAINS YIELDS A FRACTION, 50 PERCENT SHALL BE PERMITTED TO BE ROUNDED UP OR DOWN PROVIDED THAT THE TOTAL NUMBER OF DRINKING FOUNTAINS COMPLYING WITH SECTION 11B-211 EQUALS 100 PERCENT OF DRINKING FOUNTAINS. 11B-212 KITCHENS, KITCHENETTES, WET BARS AND SINKS GENERAL. WHERE PROVIDED, KITCHENS, KITCHENETTES, WET BARS AND SINKS SHALL COMPLY WITH SECTION 11B-212. 11B-212.1 KITCHENS, KITCHENETTES, AND WET BARS. KITCHENS, KITCHENETTES AND WET BARS SHALL COMPLY WITH SECTION 11B-804. 11B-212.2 SINKS. WHERE SINKS ARE PROVIDED, AT LEAST 5 PERCENT, BUT NO FEWER THAN ONE, OF EACH TYPE PROVIDED IN EACH ACCESSIBLE ROOM OR SPACE SHALL COMPLY WITH SECTION 11B-606. 11B-212.3 1. 2. EXCEPTIONS: MOP, SERVICE OR SCULLERY SINKS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-212.3. SCRUB SINKS, AS DEFINED IN CALIFORNIA PLUMBING CODE SECTION 221.0, SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-606. 11B-213 TOILET FACILITIES AND BATHING FACILITIES GENERAL. WHERE TOILET FACILITIES AND BATHING FACILITIES ARE PROVIDED, THEY SHALL COMPLY WITH SECTION 11B-213. WHERE TOILET FACILITIES AND BATHING FACILITIES ARE PROVIDED IN FACILITIES PERMITTED BY SECTION 11B-206.2.3 EXCEPTION 1 NOT TO CONNECT STORIES BY AN ACCESSIBLE ROUTE, TOILET FACILITIES AND BATHING FACILITIES SHALL BE PROVIDED ON A STORY CONNECTED BY AN ACCESSIBLE ROUTE TO AN ACCESSIBLE ENTRANCE. 11B-213.1 TOILET FACILITIES FOR DESIGNATED USER GROUPS. WHERE SEPARATE TOILET FACILITIES ARE PROVIDED FOR THE EXCLUSIVE USE OF SEPARATE USER GROUPS, THE TOILET FACILITIES SERVING EACH USER GROUP SHALL COMPLY WITH SECTION 11B-213. 11B-213.1.1 TOILET ROOMS AND BATHING ROOMS. WHERE TOILET ROOMS ARE PROVIDED, EACH TOILET ROOM SHALL COMPLY WITH SECTION 11B-603. WHERE BATHING ROOMS ARE PROVIDED, EACH BATHING ROOM SHALL COMPLY WITH SECTION 11B-603. 11B-213.2 1. 2. 3. 4. 5. EXCEPTIONS: IN ALTERATIONS WHERE IT IS TECHNICALLY INFEASIBLE TO COMPLY WITH SECTION 11B-603, ALTERING EXISTING TOILET OR BATHING ROOMS SHALL NOT BE REQUIRED WHERE A SINGLE UNISEX (SINGLE-USER OR FAMILY) TOILET ROOM OR BATHING ROOM COMPLYING WITH SECTION 11B-213.2.1 IS PROVIDED AND LOCATED IN THE SAME AREA AND ON THE SAME FLOOR AS EXISTING INACCESSIBLE TOILET OR BATHING ROOMS. RESERVED WHERE MULTIPLE SINGLE USER PORTABLE TOILET OR BATHING UNITS ARE CLUSTERED AT A SINGLE LOCATION 5 PERCENT, BUT NO FEWER THAN ONE, OF THE TOILET UNITS AND BATHING UNITS AT EACH CLUSTER SHALL COMPLY WITH SECTION 11B-603. PORTABLE TOILET UNITS AND BATHING UNITS COMPLYING WITH SECTION 11B-603 SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1. WHERE MULTIPLE SINGLE USER TOILET ROOMS ARE CLUSTERED AT A SINGLE LOCATION, 50 PERCENT, BUT NO FEWER THAN ONE, OF THE SINGLE USER TOILET ROOMS FOR EACH USE AT EACH CLUSTER SHALL COMPLY WITH SECTION 11B-603. WHERE TOILET AND BATHING ROOMS ARE PROVIDED IN GUEST ROOMS THAT ARE NOT REQUIRED TO PROVIDE MOBILITY FEATURES COMPLYING WITH SECTION 11B-806.2, TOILET AND BATHING FIXTURES SHALL ONLY BE REQUIRED TO COMPLY WITH SECTION 11B-603.6. UNISEX (SINGLE-USER OR FAMILY) TOILET AND UNISEX (SINGLE-USER OR FAMILY) BATHING ROOMS. UNISEX (SINGLE-USER OR FAMILY) TOILET ROOMS SHALL CONTAIN NOT MORE THAN ONE LAVATORY, AND NOT MORE THAN TWO WATER CLOSETS WITHOUT URINALS OR ONE WATER CLOSET AND ONE URINAL. UNISEX (SINGLE-USER OR FAMILY) BATHING ROOMS SHALL CONTAIN ONE SHOWER OR ONE SHOWER AND ONE BATHTUB, ONE LAVATORY, AND ONE WATER CLOSET. DOORS TO UNISEX (SINGLE-USER OR FAMILY) TOILET ROOMS AND UNISEX (SINGLE-USER OR FAMILY) BATHING ROOMS SHALL HAVE PRIVACY LATCHES. 11B-213.2.1 PLUMBING FIXTURES AND ACCESSORIES. PLUMBING FIXTURES AND ACCESSORIES PROVIDED IN A TOILET ROOM OR BATHING ROOM REQUIRED TO COMPLY WITH SECTION 11B-213.2 SHALL COMPLY WITH SECTION 11B-213.3. 11B-213.3 TOILET COMPARTMENTS. WHERE TOILET COMPARTMENTS ARE PROVIDED, AT LEAST FIVE PERCENT OF THE TOILET COM-PARTMENTS, OR FIVE PERCENT OF THE COMBINATION OF TOILET COMPARTMENTS AND URINALS, BUT NO FEWER THAN ONE TOILET COMPARTMENT SHALL COMPLY WITH SECTION 11B-604.8.1. IN ADDITION TO THE COMPARTMENTS REQUIRED TO COMPLY WITH SECTION 11B-604.8.1, WHERE SIX OR MORE TOILET COMPARTMENTS ARE PROVIDED, OR WHERE THE COMBINATION OF URINALS AND WATER CLOSETS TOTALS SIX OR MORE FIXTURES, TOILET COMPARTMENTS COMPLYING WITH SECTION 11B-604.8.2 SHALL BE PROVIDED IN THE SAME QUANTITY AS THE TOILET COMPARTMENTS REQUIRED TO COMPLY WITH SECTION 11B-604.8.1. 11B-213.3.1 WATER CLOSETS. WHERE WATER CLOSETS ARE PROVIDED, AT LEAST 5 PERCENT BUT NO FEWER THAN ONE SHALL COMPLY WITH SECTION 11B-604. 11B-213.3.2 URINALS. WHERE ONE OR MORE URINALS ARE PROVIDED, AT LEAST 10 PERCENT BUT NO FEWER THAN ONE SHALL COMPLY WITH SECTION 11B-605. 11B-213.3.3 LAVATORIES. WHERE LAVATORIES ARE PROVIDED, AT LEAST 10 PERCENT BUT NO FEWER THAN ONE SHALL COMPLY WITH SECTION 11B-606 AND SHALL NOT BE LOCATED IN A TOILET COMPARTMENT. 11B-213.3.4 MIRRORS. WHERE MIRRORS ARE PROVIDED, AT LEAST ONE SHALL COMPLY WITH SECTION 11B-603.3. 11B-213.3.5 BATHING FACILITIES. WHERE BATHTUBS OR SHOWERS ARE PROVIDED, AT LEAST ONE BATHTUB COMPLYING WITH SECTION 11B-607 OR AT LEAST ONE SHOWER COMPLYING WITH SECTION 11B-608 SHALL BE PROVIDED. WHERE TWO OR MORE ACCESSIBLE SHOWERS ARE PROVIDED WITHIN THE SAME FUNCTIONAL AREA, AT LEAST ONE SHOWER SHALL BE OPPOSITE HAND FROM THE OTHER OR OTHERS (THAT IS, ONE LEFT-HAND CONTROLS VERSUS RIGHT-HAND CONTROLS). TRANSFER-TYPE SHOWER COMPARTMENTS SHALL BE PERMITTED IN TRANSIENT LODGING GUEST ROOMS, MULTI-BEDROOM HOUSING UNITS IN UNDERGRADUATE STUDENT HOUSING AND RESIDENTIAL DWELLING UNITS; AND SHALL NOT BE PERMITTED AT OTHER LOCATIONS TO MEET THE REQUIREMENTS OF SECTION 11B-213.3.6. 11B-213.3.6 COAT HOOKS AND SHELVES. WHERE COAT HOOKS OR SHELVES ARE PROVIDED IN TOILET ROOMS WITHOUT TOILET COM-PARTMENTS, AT LEAST ONE OF EACH TYPE SHALL COMPLY WITH SECTION 11B-603.4. WHERE COAT HOOKS OR SHELVES ARE PROVIDED IN TOILET COMPARTMENTS, AT LEAST ONE OF EACH TYPE COMPLYING WITH SECTION 11B-604.8.3 SHALL BE PROVIDED IN TOILET COMPARTMENTS REQUIRED TO COMPLY WITH SECTION 11B-213.3.1. WHERE COAT HOOKS OR SHELVES ARE PROVIDED IN BATHING FACILITIES, AT LEAST ONE OF EACH TYPE COMPLYING WITH SECTION 11B-603.4 SHALL SERVE FIXTURES REQUIRED TO COMPLY WITH SECTION 11B-213.3.6. 11B-213.3.7 11B-215 FIRE ALARM SYSTEMS GENERAL. WHERE FIRE ALARM SYSTEMS AND CARBON MONOXIDE ALARM SYSTEMS PROVIDE AUDIBLE ALARM COVERAGE, ALARMS SHALL COMPLY WITH SECTION 11B-215. 11B-215.1 PUBLIC AND COMMON USE AREAS. ALARMS IN PUBLIC USE AREAS AND COMMON USE AREAS SHALL COMPLY WITH CHAPTER 9, SECTION 907.5.2.3.1. 11B-215.2 EMPLOYEE WORK AREAS. WHERE EMPLOYEE WORK AREAS HAVE AUDIBLE ALARM COVERAGE, THE WIRING SYSTEM SHALL BE DESIGNED SO THAT VISIBLE ALARMS COMPLYING WITH CHAPTER 9, SECTION 907.5.2.3.1 EXCEPTION CAN BE INTEGRATED INTO THE ALARM SYSTEM. 11B-215.3 RESIDENTIAL FACILITIES. WHERE PROVIDED IN RESIDENTIAL DWELLING UNITS REQUIRED TO COMPLY WITH SECTION 11B-809.5, FIRE ALARMS SHALL COMPLY WITH CHAPTER 9, SECTION 907.5.2.3.3 AND CARBON MONOXIDE ALARMS SHALL COMPLY WITH CHAPTER 9, SECTION 915. 11B-215.5 11B-216 SIGNS GENERAL. NEW OR ALTERED SIGNS SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 11B-216 AND SHALL COMPLY WITH SECTION 11B-703. THE ADDITION OF OR REPLACEMENT OF SIGNS SHALL NOT TRIGGER ANY ADDITIONAL APATH OF TRAVEL REQUIREMENTS. 11B-216.1 1. 2. 3. EXCEPTIONS: BUILDING DIRECTORIES, MENUS, SEAT AND ROW DESIGNATIONS IN ASSEMBLY AREAS, OCCUPANT NAMES, BUILDING ADDRESSES, AND COMPANY NAMES AND LOGOS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-216. RESERVED. TEMPORARY, 7 DAYS OR LESS, SIGNS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-216. DESIGNATIONS. INTERIOR AND EXTERIOR SIGNS IDENTIFYING PERMANENT ROOMS AND SPACES SHALL COMPLY WITH SECTIONS 11B-703.1, 11B-703.2, 11B-703.3 AND 11B-703.5. WHERE PICTOGRAMS ARE PROVIDED AS DESIGNATIONS OF PERMANENT ROOMS AND SPACES, THE PICTOGRAMS SHALL COMPLY WITH SECTION 11B-703.6 AND SHALL HAVE TEXT DESCRIPTORS COMPLYING WITH SECTIONS 11B-703.2 AND 11B-703.5. 11B-216.2 EXCEPTIONS: EXTERIOR SIGNS THAT ARE NOT LOCATED AT THE DOOR TO THE SPACE THEY SERVE SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-703.2. DIRECTIONAL AND INFORMATIONAL SIGNS. SIGNS THAT PROVIDE DIRECTION TO OR INFORMATION ABOUT INTERIOR AND EXTERIOR SPACES AND FACILITIES OF THE SITE SHALL COMPLY WITH SECTION 11B-703.5. 11B-216.3 MEANS OF EGRESS. SIGNS FOR MEANS OF EGRESS SHALL COMPLY WITH SECTION 11B-216.4.11B-216.4 EXIT DOORS. SIGNS REQUIRED BY CHAPTER 10, SECTION 1013.4 AT DOORS TO EXIT PASSAGEWAYS, EXIT DISCHARGE, AND EXIT STAIRWAYS SHALL COMPLY WITH SECTIONS 11B-703.1, 11B-703.2, 11B-703.3 AND 11B-703.5. 11B-216.4.1 AREAS OF REFUGE AND EXTERIOR AREAS FOR ASSISTED RESCUE. SIGNS REQUIRED BY CHAPTER 10, SEC- TION 1009.11 TO PROVIDE INSTRUCTIONS IN AREAS OF REFUGE SHALL COMPLY WITH SECTION 11B-703.5. SIGNS REQUIRED BY CHAPTER 10, SECTION 1009.9 AT DOORS TO AREAS OF REFUGE AND EXTERIOR AREAS FOR ASSISTED RESCUE SHALL COMPLY WITH SECTIONS 11B-703.1, 11B-703.2, 11B-703.3 AND 11B-703.5 AND INCLUDE AN INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1. 11B-216.4.2 DIRECTIONAL SIGNS. SIGNS REQUIRED BY CHAPTER 10, SECTION 1009.10 TO PROVIDE DIRECTIONS TO ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH SECTION 11B-703.5. 11B-216.4.3 DELAYED EGRESS LOCKS. SIGNS REQUIRED BY CHAPTER 10, SECTION 1010.1.9.7, ITEM 6.4 AT DOORS WITH DELAYED EGRESS LOCKS SHALL COMPLY WITH SECTIONS 11B-703.1, 11B-703.2, 11B-703.3 AND 11B-703.5. 11B-216.4.4 PARKING. SIGNS IDENTIFYING PARKING SPACES AND SIGNS WITHIN PARKING FACILITIES SHALL COMPLY WITH SECTION 11B-216.5.11B-216.5.1 PARKING SPACES. PARKING SPACES COMPLYING WITH SECTION 11B-502 SHALL BE IDENTIFIED BY SIGNS COMPLYING WITH SECTIONS 11B-502.6 AND 11B-502.8. 11B-216.5 1. 2. EXCEPTIONS: RESERVED. I IN RESIDENTIAL FACILITIES, WHERE PARKING SPACES ARE ASSIGNED TO SPECIFIC RESIDENTIAL DWELLING UNITS, IDENTIFICATION OF ACCESSIBLE PARKING SPACES SHALL NOT BE REQUIRED. PARKING FACILITIES. SIGNS WITHIN PARKING FACILITIES SHALL COMPLY WITH SECTION 11B-216.5.2. 11B-216.5.2 SIGNS INTENDED FOR USE BY PEDESTRIANS. SIGNS INTENDED FOR USE BY PEDESTRIANS WITHIN PARKING FACILITIES, INCLUDING DIRECTIONAL OR INFORMATIONAL SIGNS INDICATING PARKING SECTIONS OR LEVELS, SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 11B-216. 11B-216.5.2.1 ADDITIONAL SIGNS. SIGNS WITHIN PARKING FACILITIES CONTAINING PARKING SPACES COMPLYING WITH SECTION 11B-502 SHALL COMPLY WITH SECTION 11B-502.8. 11B-216.5.2.2 ENTRANCES. IN EXISTING BUILDINGS AND FACILITIES WHERE NOT ALL ENTRANCES COMPLY WITH SECTION 11B-404, ENTRANCES COMPLYING WITH SECTION 11B-404 SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1. DIRECTIONAL SIGNS COMPLYING WITH SECTION 11B-703.5 THAT INDICATE THE LOCATION OF THE NEAREST ENTRANCE COMPLYING WITH SECTION 11B-404 SHALL BE PROVIDED AT ENTRANCES THAT DO NOT COMPLY WITH SECTION 11B-404. DIRECTIONAL SIGNS COMPLYING WITH SECTION 11B-703.5, INCLUDING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1, INDICATING THE ACCESSIBLE ROUTE TO THE NEAREST ACCESSIBLE ENTRANCE SHALL BE PROVIDED AT JUNCTIONS WHEN THE ACCESSIBLE ROUTE DIVERGES FROM THE REGULAR CIRCULATION PATH. 11B-216.6 ELEVATORS. WHERE EXISTING ELEVATORS DO NOT COMPLY WITH SECTION 11B-407, ELEVATORS COMPLYING WITH SECTION 11B-407 SHALL BE CLEARLY IDENTIFIED WITH THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1. EXISTING BUILDINGS THAT HAVE BEEN REMODELED TO PROVIDE SPECIFIC ELEVATORS FOR PUBLIC USE THAT COMPLY WITH THESE BUILDING STANDARDS SHALL HAVE THE LOCATION OF AND THE DIRECTIONS TO THESE ELEVATORS POSTED IN THE BUILDING LOBBY ON A SIGN COMPLYING WITH SECTION 11B-703.5, INCLUDING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1. 11B-216.7 TOILET ROOMS AND BATHING ROOMS. WHERE EXISTING TOILET ROOMS OR BATHING ROOMS DO NOT COMPLY WITH SECTION 11B-603, DIRECTIONAL SIGNS INDICATING THE LOCATION OF THE NEAREST TOILET ROOM OR BATHING ROOM COMPLYING WITH SECTION 11B-603 WITHIN THE FACILITY SHALL BE PROVIDED. SIGNS SHALL COMPLY WITH SECTION 11B-703.5 AND SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1. WHERE EXISTING TOILET ROOMS OR BATHING ROOMS DO NOT COMPLY WITH SECTION 11B-603, THE TOILET ROOMS OR BATHING ROOMS COMPLYING WITH SECTION 11B-603 SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1. WHERE CLUSTERED SINGLE USER TOILET ROOMS OR BATHING FACILITIES ARE PERMITTED TO USE EXCEPTIONS TO SECTION 11B-213.2, TOILET ROOMS OR BATHING FACILITIES COMPLYING WITH SECTION 11B-603 SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1 UNLESS ALL TOILET ROOMS AND BATHING FACILITIES COMPLY WITH SECTION 11B-603. EXISTING BUILDINGS THAT HAVE BEEN REMODELED TO PROVIDE SPECIFIC TOILET ROOMS OR BATHING ROOMS FOR PUBLIC USE THAT COMPLY WITH THESE BUILDING STANDARDS SHALL HAVE THE LOCATION OF AND THE DIRECTIONS TO THESE ROOMS POSTED IN OR NEAR THE BUILDING LOBBY OR ENTRANCE ON A SIGN COMPLYING WITH SECTION 11B-703.5, INCLUDING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1. 11B-216.8 GEOMETRIC SYMBOLS. GEOMETRIC SYMBOLS COM-PLYING WITH SECTION 11B-703.7.2.6 SHALL BE PROVIDED AT ENTRANCES TO TOILET AND BATHING ROOMS. 11B-216.8.1 1. 2. EXCEPTIONS: GEOMETRIC SYMBOLS SHALL NOT BE REQUIRED AT ENTRANCES TO TOILET AND BATHING ROOMS LOCATED WITHIN PRIVATE OR SEMI-PRIVATE ROOMS OR SPACES. SUCH SPACES INCLUDE BUT ARE NOT LIMITED TO: PATIENT SLEEPING ROOMS, TRANSIENT LODGING GUEST ROOMS, AND RESIDENTIAL DWELLING UNITS. GEOMETRIC SYMBOLS SHALL NOT BE REQUIRED AT ENTRANCES TO INMATE TOILET ROOMS AND BATHING ROOMS IN DETENTION AND CORRECTIONAL FACILITIES WHERE ONLY ONE GENDER IS HOUSED. TTYS. IDENTIFICATION AND DIRECTIONAL SIGNS FOR PUBLIC TTYS SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 11B-216.9. 11B-216.9 IDENTIFICATION SIGNS. PUBLIC TTYS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF TTY COMPLYING WITH SECTION 11B-703.7.2.2. 11B-216.9.1 DIRECTIONAL SIGNS. DIRECTIONAL SIGNS INDICATING THE LOCATION OF THE NEAREST PUBLIC TTY SHALL BE PROVIDED AT ALL BANKS OF PUBLIC PAY TELEPHONES NOT CONTAINING A PUBLIC TTY. IN ADDITION, WHERE SIGNS PROVIDE DIRECTION TO PUBLIC PAY TELEPHONES, THEY SHALL ALSO PROVIDE DIRECTION TO PUBLIC TTYS. IF A FACILITY HAS NO BANKS OF TELEPHONES, THE DIRECTIONAL SIGNS SHALL BE PROVIDED AT THE ENTRANCE OR IN A BUILDING DIRECTORY. DIRECTIONAL SIGNS SHALL COMPLY WITH SECTION 11B- 703.5 AND SHALL INCLUDE THE INTERNATIONAL SYMBOL OF TTY COMPLYING WITH SECTION 11B-703.7.2.2. 11B-216.9.2 ASSISTIVE LISTENING SYSTEMS. EACH ASSEMBLY AREA REQUIRED BY SECTION 11B-219 TO PROVIDE ASSISTIVE LISTENING SYSTEMS SHALL PROVIDE SIGNS INFORMING PATRONS OF THE AVAILABILITY OF THE ASSISTIVE LISTENING SYSTEM. THE SIGN SHALL INCLUDE WORDING THAT STATES “ASSISTIVE-LISTENING SYSTEM AVAILABLE ” AND SHALL BE POSTED IN A PROMINENT PLACE AT OR NEAR THE ASSEMBLY AREA ENTRANCE. ASSISTIVE LISTENING SIGNS SHALL COMPLY WITH SECTION 11B-703.5 AND SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS COMPLYING WITH SECTION 11B-703.7.2.4. 11B-216.10 EXCEPTIONS:WHERE TICKET OFFICES OR WINDOWS ARE PROVIDED, SIGNS SHALL NOT BE REQUIRED AT EACH ASSEMBLY AREA PROVIDED THAT SIGNS ARE DISPLAYED AT EACH TICKET OFFICE OR WINDOW INFORMING PATRONS OF THE AVAILABILITY OF ASSISTIVE LISTENING SYSTEMS. 1DIVISION 1 - APPLICATION 2DIVISION 2 - SCOPING REQUIREMENTS 3DIVISION 203 - GENERAL EXCEPTIONS 4DIVISION 204 - PROTRUDING OBJECTS 5DIVISION 205 - OPERABLE PARTS 6DIVISION 206 - ACCESSIBLE ROUTES 7DIVISION 207 - ACCESSIBLE EGRESS8DIVISION 208 - PARKING SPACES 9 DIVISION 209 LOADING ZONES & BUS STOPS 10DIVISION 210 - STAIRWAYS 11DIVISION 211 - DRINKING FOUNTAINS 12DIVISION 212 - KITCHENS, BARS & SINKS 13 DIVISION 213 - TOILETS & BATHING FACILITIES 14DIVISION 215 - FIRE ALARMS 15DIVISION 216 - SIGNS A0.5a CBC 11B DIV 1 & DIV 2 APPLICATION AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 11B-226 DINING SURFACES AND WORK SURFACES 11B-226.1 GENERAL. WHERE DINING SURFACES ARE PROVIDED FOR THE CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE SEATING SPACES AND STANDING SPACES AT THE DINING SURFACES SHALL COMPLY WITH SECTION 11B-902 IN ADDITION, WHERE WORK SURFACES ARE PROVIDED FOR USE BY OTHER THAN EMPLOYEES, AT LEAST 5 PERCENT SHALL COMPLY WITH SECTION 11B-902. 11B-226.2 DISPERSION. DINING SURFACES REQUIRED TO COMPLY WITH SECTION 11B-902 SHALL BE DISPERSED THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING SURFACES FOR EACH TYPE OF SEATING IN A FUNCTIONAL AREA WORK SURFACES REQUIRED TO COMPLY WITH SECTION 11B-902 SHALL BE DISPERSED THROUGHOUT THE SPACE OR FACILITY CONTAINING WORK SURFACES. 11B-226.3 DINING SURFACES EXCEEDING 34 INCHES IN HEIGHT. WHERE FOOD OR DRINK IS SERVED FOR CONSUMPTION AT A COUNTER EXCEEDING 34 INCHES (864 MM) IN HEIGHT, A PORTION OF THE MAIN COUNTER 60 INCHES (1525 MM) MINIMUM IN LENGTH SHALL BE PROVIDED IN COMPLIANCE WITH SECTION 11B-902.3. 11B-226.4 BABY CHANGING TABLES. BABY CHANGING TABLES SHALL COMPLY WITH SECTIONS 11B-309 AND 11B-902. BABY CHANGING TABLES WHEN DEPLOYED SHALL NOT OBSTRUCT THE REQUIRED WIDTH OF AN ACCESSIBLE ROUTE EXCEPT AS ALLOWED BY SECTION 11B-307.2. BABY CHANGING TABLES SHALL NOT BE LOCATED IN TOILET COMPARTMENTS COMPLYING WITH SECTION 11B-604.8 WITHIN A MULTIPLE ACCOMMODATION TOILET FACILITY. 11B-228 DEPOSITORIES, VENDING MACHINES, CHANGE MACHINES, MAIL BOXES, AND FUEL DISPENSERS 11B-228.1 GENERAL. WHERE PROVIDED, AT LEAST ONE OF EACH TYPE OF DEPOSITORY, VENDING MACHINE, CHANGE MACHINE, AND FUEL DISPENSER SHALL COMPLY WITH SECTION 11B-309 ELECTRIC VEHICLE CHARGING STATIONS SHALL COMPLY WITH SECTION 11B-228.3. EXCEPTION: DRIVE-UP ONLY DEPOSITORIES SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-309. 11B-228.2 MAIL BOXES. WHERE MAIL BOXES ARE PROVIDED IN AN INTERIOR LOCATION, AT LEAST 5 PERCENT, BUT NO FEWER THAN ONE, OF EACH TYPE SHALL COMPLY WITH SECTION 11B-309. IN RESIDENTIAL FACILITIES, WHERE MAIL BOXES ARE PROVIDED FOR EACH RESIDENTIAL DWELLING UNIT, MAIL BOXES COMPLYING WITH SECTION 11B-309 SHALL BE PROVIDED FOR EACH RESIDENTIAL DWELLING UNIT REQUIRED TO PRODE MOBILITY FEATURES COMPLYING WITH SECTIONS 11B-809.2 THROUGH 11B-809.4 AND ADAPTABLE FEATURES COMPLYING WITH CHAPTER 11A, DIVISION IV. 11B-228.3 ELECTRIC VEHICLE CHARGING STATIONS 11B-228.3.1 GENERAL WHERE ELECTRIC VEHICLE CHARGING STATIONS (EVCS) ARE PROVIDED, EVCS SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 11B-228.3. 11B-228.3.1.2 OPERABLE PARTS. WHERE EV CHARGERS ARE PROVIDED, OPERABLE PARTS ON ALL EV CHARGERS SHALL COMPLY WITH SECTION 11B-309.4. 11B-228.3.2 MINIMUM NUMBER. EVCS COMPLYING WITH SECTION 11B-812 SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 11B-228.3.2. WHERE EVCS ARE PROVIDED IN MORE THAN ONE FACILITY ON A SITE, THE NUMBER OF EVCS COMPLYING WITH SECTION 11B-228.3.2 PROVIDED ON THE SITE SHALL BE CALCULATED ACCORDING TO THE NUMBER REQUIRED FOR EACH FACILITY. WHERE AN EV CHARGER CAN SIMULTANEOUSLY CHARGE MORE THAN ONE VEHICLE, THE NUMBER OF EV CHARGERS PROVIDED SHALL BE CONSIDERED EQUIVALENT TO THE NUMBER OF ELECTRIC VEHICLES THAT CAN BE SIMULTANEOUSLY CHARGED. EXCEPTIONS: 1. EVCS NOT AVAILABLE TO THE GENERAL PUBLIC AND INTENDED FOR USE BY A DESIGNATED VEHICLE OR DRIVER SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-228.3.2 EXAMPLES INCLUDE, BUT ARE NOT LIMITED TO, EVCS SERVING PUBLIC OR PRIVATE FLEET VEHICLES AND EVCS ASSIGNED TO AN EMPLOYEE. 2. IN PUBLIC HOUSING FACILITIES, EVCS INTENDED FOR USE BY AN EV OWNER OR OPERATOR AT THEIR RESIDENCE SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-228.3.2. TBLE 11B-228.3.2.1 ELECTRIC VEHICLE CHARGING STATIONS FOR PUBLIC AND COMMON USE TOTAL NUMBER OF EVCS AT A FACILITY1 MINIMUM NUMBER (by type) OF EVCS REQUIRED TO COMPLY WITH SECTION 11B-8121 1 to 4 5 to 25 26 to 50 51 to 75 76 to 100 101 to over 1 1 1 1 1 1, plus 1 for each 300, or fraction thereof, over 100 0 1 1 2 3 3, plus 1 for each 60, or fraction thereof, over 100 0 0 1 2 3 3, plus 1 for each 50, or fraction thereof, over 100 VAN ACCESSIBLE STANDARD ACCESSIBILE AMBULATORY 1. where an EV charger can simultaneously charge more than one vehicle, the number of EVCS provided shall be considered equivalent to the number of electric vehicles that can be simultaneously charged. 11B-229 WINDOWS 11B-229.1 GENERAL. WHERE GLAZED OPENINGS ARE PROVIDED IN ACCESSIBLE ROOMS OR SPACES FOR OPERATION BY OCCUPANTS, AT LEAST ONE OPENING SHALL COMPLY WITH SECTION 11B-309. EACH GLAZED OPENING REQUIRED BY AN ADMINISTRATIVE AUTHORITY TO BE OPERABLE SHALL COMPLY WITH SECTION 11B-309. EXCEPTION: 1. GLAZED OPENINGS IN RESIDENTIAL DWELLING UNITS REQUIRED TO COMPLY WITH SECTION 11B-809 SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-229. 2. GLAZED OPENINGS IN GUEST ROOMS REQUIRED TO PROVIDE COMMUNICATION FEATURES AND IN GUEST ROOMS REQUIRED TO COMPLY WITH SECTION 11B-206 5.3 SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-229. 11B-230 TWO-WAY COMMUNICATION SYSTEMS 11B-230.1 GENERAL. WHERE A TWO-WAY COMMUNICATION SYSTEM IS PROVIDED TO GAIN ADMITTANCE TO A BUILDING OR FACILITY OR TO RESTRICTED AREAS WITHIN A BUILDING OR FACILITY, THE SYSTEM SHALL COMPLY WITH SECTION 11B-708. 11B-247 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE 11B-247.1.1 GENERAL. DETECTABLE WARNINGS SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 11B-247.1 AND SHALL COMPLY WITH SECTION 11B-705.1. 11B-247.1.2 WHERE REQUIRED. DETECTABLE WARNINGS SHALL BE PROVIDED WHERE REQUIRED BY SECTION 11B-247.1.2 11B-247.1.2.1 PLATFORM EDGES. PLATFORM BOARDING EDGES SHALL HAVE DETECTABLE WARNINGS COMPLYING WITH SECTIONS 11B-705.1.1 AND 11B-705.1.2.1. 11B-247.1.2.2 CURE RAMPS. CURB RAMPS SHALL HAVE DETECTABLE WARNINGS COMPLYING WITH SECTIONS 11B-705.1.1 AND 11B-705.1.2.2. 11B-247.1.2.3 ISLANDS OR CUT-THROUGH MEDIANS. ISLANDS OR CUT-THROUGH MEDIANS SHALL HAVE DETECTABLE WARNINGS COMPLYING WITH SECTIONS 11B-705.1.1 AND 11B-705.1.2.3. 11B-247.1.2.4 BUS STOPS. WHERE DETECTABLE WARNINGS ARE PROVIDED AT BUS STOP BOARDING AND ALIGHTING AREAS IN COMPLIANCE WITH SECTION 11B-810.2.3, DETECTABLE WARNINGS SHALL COMPLY WITH SECTIONS 11B-705.1.1 AND 11B-705.1.2.4. 11B-247.1.2.5 HAZARDOUS VEHICULAR AREAS IF A WALK CROSSES OR ADJOINS A VEHICULAR WAY, AND THE WALKING SURFACES ARE NOT SEPARATED BY CURBS, RAILINGS OR OTHER ELEMENTS BETWEEN THE PEDESTRIAN AREAS AND VEHICULAR AREAS, THE BOUNDARY BETWEEN THE AREAS SHALL BE DEFINED BY A CONTINUOUS DETECTABLE WARNING COMPLYING WITH SECTIONS 11B-705.1.1 AND 11B-705.1.2.5 11B-247.1.2.6 REFLECTING POOLS. THE EDGES OF REFLECTING POOLS SHALL BE PROTECTED BY RAILINGS WALLS WARNING CURBS OR DETECTABLE WARNINGS COMPLYING WITH SECTIONS 11B-705.1.1 AND 11B-705.1.2.6. 11B-247.1.2.7 TRACK CROSSINGS. WHERE IT IS NECESSARY TO CROSS TRACKS TO REACH TRANSIT BOARDING PLATFORMS, DETECTABLE WARNINGS COMPLYING WITH SECTIONS 11B-705.1.1 AND 11B-705.1.2.7 SHALL BE PROVIDED. 11B-247.2 DETECTABLE DIRECTIONAL TEXTURE. AT TRANSIT BOARDING PLATFORMS, THE PEDESTRIAN ACCESS SHALL BE IDENTIFIED WITH A DETECTABLE DIRECTIONAL TEXTURE COMPLYING WITH SECTION 11B-705.2. DIVISION3: BUILDING BLOCKS 11B-301 GENERAL 11B-301.1 SCOPE. THE PROVISIONS OF DIVISION 3 SHALL APPLY WHERE REQUIRED BY DIVISION 2 OR WHERE REFERENCED BY A REQUIREMENT IN THIS CHAPTER. 11B-302 FLOOR OR GROUND SURFACES 11B-302.1 GENERAL FLOOR AND GROUND SURFACES SHALL BE STABLE, FIRM, AND SLIP RESISTANT AND SHALL COMPLY WITH SECTION 11B-302. EXCEPTIONS: 1. WITHIN ANIMAL CONTAINMENT AREAS, FLOOR AND GROUND SURFACES SHALL NOT BE REQUIRED TO BE STABLE, FIRM, AND SLIP RESISTANT. 2. AREAS OF SPORT ACTIVITY SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-302. 11B-302.2 CARPET. CARPET OR CARPET TILE SHALL BE SECURELY ATTACHED AND SHALL HAVE A FIRM CUSHION, PAD, OR BACKING OR NO CUSHION OR PAD CARPET OR CARPET TILE SHALL HAVE A LEVEL LOOP, TEXTURED LOOP, LEVEL CUT PILE, LEVEL CUT/UNCUT PILE TEXTURE. PILE HEIGHT SHALL BE 1/2 INCH (12.7 MM) MAXIMUM. EXPOSED EDGES OF CARPET SHALL BE FASTENED TO FLOOR SURFACES AND SHALL HAVE TRIM ON THE ENTIRE LENGTH OF THE EXPOSED EDGE. CARPET EDGE TRIM SHALL COMPLY WITH SECTION 11B-303. 11B-302.3 OPENINGS. OPENINGS IN FLOOR OR GROUND SURFACES SHALL NOT ALLOW PASSAGE OF A SPHERE MORE THAN 1/2 INCH (12.7 MM) DIAMETER EXCEPT AS ALLOWED IN SECTIONS 11B-407.4.3, 11B-409.4.3, 11B-410.4, 11B-810.5.3 AND 11B-810.10 ELONGATED OPENINGS SHALL BE PLACED SO THAT THE LONG DIMENSION IS PERPENDICULAR TO THE DOMINANT DIRECTION OF TRAVEL. 12 . 7 1/ 2 " MA X 12.7 1/2 MAX . LONG DIMENSION PERPENDICULAR TO DOMINANT DIRECTION OF TRAVEL DOMINANT DIRECTION OF TRAVEL FIGURE 11B-302.3 ELONGATED OPENINGS IN FLOOR OR GROUND SURFACES FIGURE 11B-302.2 CARPET PILE HEIGHT 11B-303 CHANGES IN LEVEL 11B-303.1 GENERAL. WHERE CHANGES IN LEVEL ARE PERMITTED IN FLOOR OR GROUND SURFACES, THEY SHALL COMPLY WITH SECTION 11B-303. EXCEPTIONS: 1. ANIMAL CONTAINMENT AREAS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-303. 2. AREAS OF SPORT ACTIVITY SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-303. 11B-303.2 VERTICAL. CHANGES IN LEVEL OF 1/4 INCH (6.4 mm) HIGH MAXIMUM SHALL BE PERMITTED TO BE VERTICAL AND WITHOUT EDGE TREATMENT. 11B-303.3 BEVELED. CHANGES IN LEVEL BETWEEN 1/4 INCH (6.4 mm) HIGH MINIMUM 1/2 INCH (12.7 mm) HIGH MAXIMUM SHALL BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2. 11B-303.4 RAMPS. CHANGES IN LEVEL GREATER THAN 1/2 INCH (12.7 mm) HIGH SHALL BE RAMPED, AND SHALL COMPLY WITH SECTION 11B-405 OR 11B-406. 11B-303.5 WARNING CURBS. ABRUPT CHANGES IN LEVEL EXCEEDING 4 INCHES (102 mm) IN A VERTICAL DIMENSION BETWEEN WALKS, SIDEWALKS OR OTHER PEDESTRIAN WAYS AND ADJACENT SUR-FACES OR FEATURES SHALL BE IDENTIFIED BY WARNING CURBS AT LEAST 6 INCHES (152 MM) IN HEIGHT ABOVE THE WALK OR SIDEWALK SURFACE. EXCEPTIONS: 1. A WARNING CURB IS NOT REQUIRED BETWEEN A WALK OR SIDEWALK AND AN ADJACENT STREET OR DRIVEWAY. 2. A WARNING CURB IS NOT REQUIRED WHEN A GUARD OR HANDRAIL IS PROVIDED WITH A GUIDE RAIL CENTERED 2 INCHES (51 mm) MINIMUM AND 4 INCHES (102 MM) MAXIMUM ABOVE THE SURFACE OF THE WALK OR SIDEWALK. 6. 4 1/ 4 " MA X 6. 4 1/ 4 " MA X 6. 4 1/ 4 " MA X 12 . 7 1/ 2 " MA X FIGURE 11B-303.2 VERTICAL CHANGE IN LEVEL FIGURE 11B-303.3 BEVELED CHANGE IN LEVEL 2 1 11B-304 TURNING SPACE 11B-304.1 GENERAL. TURNING SPACE SHALL COMPLY WITH SECTION 11B-304. 11B-304.2 FLOOR OR GROUND SURFACES. FLOOR OR GROUND SURFACES OF A TURNING SPACE SHALL COMPLY WITH SECTION 11B-302. CHANGES IN LEVEL ARE NOT PERMITTED. EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED. 11B-304.3 SIZE. TURNING SPACE SHALL COMPLY WITH SECTION 11B-304.3.1 OR 11B-304.3.2. 11B-304.3.1 CIRCULAR SPACE. THE TURNING SPACE SHALL BE A SPACE OF 60 INCHES (1524 mm) DIAMETER MINIMUM. THE SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11B-306. 11B-304.3.2 T-SHAPED SPACE. THE TURNING SPACE SHALL BE A T-SHAPED SPACE WITHIN A 60 INCH (1524 mm) SQUARE MINIMUM WITH ARMS AND BASE 36 INCHES (914 mm) WIDE MINIMUM. EACH ARM OF THE T SHALL BE CLEAR OF OBSTRUCTIONS 12 INCHES (305 mm) MINIMUM IN EACH DIRECTION AND THE BASE SHALL BE CLEAR OF OBSTRUCTIONS 24 INCHES (610 mm) MINIMUM THE SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11B-306 ONLY AT THE END OF EITHER THE BASE OR ONE ARM. 11B-304.4 DOOR SWING. DOORS SHALL BE PERMITTED TO SWING INTO TURNING SPACES. 305 1'-0" MIN 914 3'-0" MIN 305 1'-0" MIN 15 2 4 5' - 0 " M I N 1524 5'-0" MIN 91 4 3' - 0 " M I N 61 0 2' - 0 " M I N AR M AR M BASE FIGURE 11B-304.3.2 T-SHAPED TURNING SPACE FIGURE 11B-304.3.1 CIRCULAR TURNING SPACE 1524 5'-0" MIN CLEAR 11B-305.1 GENERAL. CLEAR FLOOR OR GROUND SPACE SHALL COMPLY WITH SECTION 11B-305 11B-305.2 FLOOR OR GROUND SURFACES. FLOOR OR GROUND SURFACES OF A CLEAR FLOOR OR GROUND SPACE SHALL COMPLY WITH SECTION 11B-302. CHANGES IN LEVEL ARE NOT PERMITTED. EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED. 11B-305.3 SIZE THE CLEAR FLOOR OR GROUND SPACE SHALL BE 30 INCHES (762 mm) MINIMUM BY 48 INCHES (1219 mm) MINIMUM. 11B-305.4 KNEE AND TOE CLEARANCE. UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR GROUND SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11B-306. 11B-305.5 POSITION. UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR GROUND SPACE SHALL BE POSITIONED FOR EITHER FORWARD OR PARALLEL APPROACH TO AN ELEMENT. 11B-305.6 APPROACH. ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND SPACE SHALL ADJOIN AN ACCESSIBLE ROUTE OR ADJOIN ANOTHER CLEAR FLOOR OR GROUND SPACE. CLEAR FLOOR OR GROUND SPACE MAY OVERLAP AN ACCESSIBLE ROUTE, UNLESS SPECIFICALLY PROHIBITED ELSEWHERE IN THIS CHAPTER. 11B-305.7 MANEUVERING CLEARANCE WHERE A CLEAR FLOOR OR GROUND SPACE IS LOCATED IN AN ALCOVE OR OTHERWISE CONFINED ON ALL OR PART OF THREE SIDES, ADDITIONAL MANEUVERING CLEARANCE SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS 11B-305.7.1 AND 11B-305.7.2. 11B-305.7.1 FORWARD APPROACH. ALCOVES SHALL BE 36 INCHES (914 mm) WIDE MINIMUM WHERE THE DEPTH EXCEEDS 24 INCHES (610 mm). 11B-305.7.2 PARALLE APPROACH. ALCOVES SHALL BE 60 INCHES (1524 MM) WIDE MINIMUM WHERE THE DEPTH EXCEEDS 15 INCHES (381 MM). 1524 5'-0" MIN 38 1 X> 1 ' - 3 " 91 4 3'- 0 " M I N 610 X>2'-0" 1219 4'-0" MIN 76 2 2' - 6 " M I N 76 2 2'- 6 " M I N 1219 4'-0" MIN 1219 4'-0" MIN 76 2 2' - 6 " M I N FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH FIGURE 11B-305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD APPROACH FIGURE 11B-305.5 POSITION OF CLEAR FLOOR OR GROUND SPACE (a) forward (b) parallel FIGURE 11B-305.3 CLEAR FLOOR OR GROUND SPACE 11B-306 KNEE AND TOE CLEARANCE 11B-308.1 GENERAL. WHERE SPACE BENEATH AN ELEMENT IS INCLUDED AS PART OF CLEAR FLOOR OR GROUND SPACE OR TURNING SPACE, THE SPACE SHALL COMPLY WITH SECTION 11B-306. ADDITIONAL SPACE SHALL NOT BE PROHIBITED BENEATH AN ELEMENT BUT SHALL NOT BE CONSIDERED AS PART OF THE CLEAR FLOOR OR GROUND SPACE OR TURNING SPACE. 11B-306.2 TOE CLEARANCE 11B-306.2.1 GENERAL. SPACE UNDER AN ELEMENT BETWEEN THE FINISH FLOOR OR GROUND AND 9 INCHES (229 mm) ABOVE THE FINISH FLOOR OR GROUND SHALL BE CONSIDERED TOE CLEARANCE AND SHALL COMPLY WITH SECTION 11B-306.2. 11B-306.2.2 MAXIMUM DEPTH. TOE CLEARANCE SHALL EXTEND 25 INCHES (635 mm) MAXIMUM UNDER AN ELEMENT. EXCEPTION TOE CLEARANCE SHALL EXTEND 19 INCHES (483 mm) MAXIMUM UNDER LAVATORIES REQUIRED TO BE ACCESSIBLE BY SECTION 11B-213.3.4. 11B-306.2.3 MINIMUM REQUIRED DEPTH. WHERE TOE CLEARANCE IS REQUIRED AT AN ELEMENT AS PART OF A CLEAR FLOOR SPACE, THE TOE CLEARANCE SHALL EXTEND 17 INCHES (432 mm) MINIMUM UNDER THE ELEMENT. EXCEPTIONS: 1. THE TOE CLEARANCE SHALL EXTEND 19 INCHES (483 mm) MINIMUM UNDER SINKS REQUIRED TO BE ACCESSIBLE BY SECTION 11B-212.3. 2. THE TOE CLEARANCE SHALL EXTEND 19 INCHES (483 mm) MINIMUM UNDER BULT IN DINING AND WORK SURFACES REQUIRED TO BE ACCESSIBLE. 11B-306.2.4 ADDITIONAL CLEARANCE. SPACE EXTENDING GREATER THAN 6 INCHES (152 mm) BEYOND THE AVAILABLE KNEE CLEARANCE AT 9 INCHES (229 mm) ABOVE THE FINISH FLOOR OR GROUND SHALL NOT BE CONSIDERED TOE CLEARANCE. 11B-306.2.5 WIDTH. TOE CLEARANCE SHALL BE 30 INCHES (762 mm) WIDE MINIMUM. 11B-306.3 KNEE CLEARANCE. 11B-306.3.1 GENERAL. SPACE UNDER AN ELEMENT BETWEEN 9 INCHES (229 mm) AND 27 INCHES (686 mm) ABOVE THE FINISH FLOOR OR GROUND SHALL BE CONSIDERED KNEE CLEARANCE AND SHALL COMPLY WITH SECTION 11B-306.3. EXCEPTION: AT LAVATORIES REQUIRED TO BE ACCESSIBLE BY SECTION 11B-213.3.4, SPACE BETWEEN 9 INCHES (229 mm) AND 29 INCHES (737 mm) ABOVE THE FINISH FLOOR OR GROUND, SHALL BE CONSIDERED KNEE CLEARANCE. 11B-306.3.2 MAXIMUM DEPTH. KNEE CLEARANCE SHALL EXTEND 25 INCHES (635 mm) MAXIMUM UNDER AN ELEMENT AT 9 INCHES (229 mm) ABOVE THE FINISH FLOOR OR GROUND. 11B-306.3.3 MINIMUM REQUIRED DEPTH. WHERE KNEE CLEARANCE IS REQUIRED UNDER AN ELEMENT AS PART OF A CLEAR FLOOR SPACE, THE KNEE CLEARANCE SHALL BE 11 INCHES (279 mm) DEEP MINIMUM AT 9 INCHES (229 mm) ABOVE THE FINISH FLOOR OR GROUND, AND 8 INCHES (203 mm) DEEP MINIMUM AT 27 INCHES (686 mm) ABOVE THE FINISH FLOOR OR GROUND. EXCEPTIONS: 1. AT LAVATORIES REQUIRED TO BE ACCESSIBLE BY SECTION 11B-213.3.4, THE KNEE CLEARANCE SHALL BE 27 INCHES (686 mm) HIGH MINIMUM ABOVE THE FINISH FLOOR OR GROUND AT A DEPTH OF 8 INCHES (203 mm) MINIMUM INCREASING TO 29 INCHES (737 mm) HIGH MINIMUM ABOVE THE FINISH FLOOR OR GROUND AT THE FRONT EDGE OF A COUNTER WITH A BUILT-IN LAVATORY OR AT THE FRONT EDGE OF A WALL-MOUNTED LAVATORY FIXTURE. 2. AT DINING AND WORK SURFACES REQUIRED TO BE ACCESSIBLE, KNEE CLEARANCE SHALL EXTEND 19 INCHES (483 mm) DEEP MINMUM AT 27 INCHES (686 mm) ABOVE THE FINISH FLOOR OR GROUND. 11B-306.3.4 CLEARANCE REDUCTION. BETWEEN 9 INCHES (229 mm) AND 27 INCHES (686 mm) ABOVE THE FINISH FLOOR OR GROUND, THE KNEE CLEARANCE SHALL BE PERMITTED TO REDUCE AT A RATE OF 1 INCH (25 MM ) IN DEPTH FOR EACH 6 INCHES (152 mm) IN HEIGHT. EXCEPTION: THE KNEE CLEARANCE SHALL NOT BE REDUCED AT BUILT-IN DINING AND WORK SURFACES REQUIRED TO BE ACCESSIBLE BY SECTION 11B-226.1. 11B-306.3.5 WIDTH. KNEE CLEARANCE SHALL BE 30 INCHES (762 mm) WIDE MINIMUM. 22 99"MI N 68 6 2' - 3 " M I N 73 7 2'- 5 " M I N 203 8" MIN 279 11" MAX 22 99"MI N 203 8" MIN 279 11" MAX 68 6 2'- 3 " M I N 22 99" 152 6" MAX 76 2 2'- 6 " M I N 432-635 17"-25" 76 2 2' - 6 " M I N 279 2"-1" MAX FIGURE 11B-306.3 KNEE CLEARANCE (c) elevation at lavatory (a) elevation (c) elevation at lavatory FIGURE 11B-306.2 TOE CLEARANCE (a) elevation (b) plan 11B-307 PROTRUDING OBJECTS 11B-307.1 GENERAL PROTRUDING OBJECTS SHALL COMPLY WITH SECTION 11B-307. 11B-307.2 PROTRUSION LIMITS. OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES (686 mm) AND NOT MORE THAN 80 INCHES (2032 mm) ABOVE THE FINISH FLOOR OR GROUND SHALL PROTRUDE 4 INCHES (102 mm) MAXIMUM HORIZONTALLY INTO THE CIRCULATION PATH. EXCEPTION: HANDRAILS SHALL BE PERMITTED TO PROTRUDE 4 INCHES (114 mm) MAXIMUM. 11B-307.3 POST-MOUNTED OBJECTS. FREE-STANDING OBJECTS MOUNTED ON POSTS OR PYLONS SHALL OVERHANG CIRCULATION PATHS 12 INCHES (305 mm) MAXIMUM WHEN LOCATED 27 INCHES (686 mm) MINIMUM AND 80 INCHES (2032 mm) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. WHERE A SIGN OR OTHER OBSTRUCTION IS MOUNTED BETWEEN POSTS OR PYLONS AND THE CLEAR DISTANCE BETWEEN THE POSTS OR PYLONS IS GREATER THAN 12 INCHES (305 mm), THE LOWEST EDGE OF SUCH SIGN OR OBSTRUCTION SHALL BE 27 INCHES (686 mm) MAXIMUM OR 80 INCHES (2032 mm) MINIMUM ABOVE THE FINISH FLOOR OR GROUND. EXCEPTION: THE SLOPING PORTIONS OF HANDRAILS SERVING STAIRS AND RAMPS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-307.3. 11B-307.3.1 EDGES AND CORNERS. WHERE SIGNS OR OTHER OBJECTS ARE MOUNTED ON POSTS OR PYLONS, AND THEIR BOTTOM EDGES ARE LESS THAN 80 INCHES (2032 mm) ABOVE THE FLOOR OR GROUND SURFACE, THE EDGES OF SUCH SIGNS AND OBJECTS SHALL BE ROUNDED OR EASED AND THE CORNERS SHALL HAVE A MINIMUM RADIUS OF 1/8 INCH (3.2 mm). 11B-307.4 VERTICAL CLEARANCE. VERTICAL CLEARANCE SHALL BE 80 INCHES (2032 mm) HIGH MINIMUM. GUARDRAILS OR OTHER BARRIERS SHALL BE PROVIDED WHERE THE VERTICAL CLEARANCE IS LESS THAN 80 INCHES (2032 mm) HIGH. THE LEADING EDGE OF SUCH GUARDRAIL OR BARRIER SHALL BE LOCATED 27 INCHES (686 mm) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. EXCEPTION: DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES (1981 mm) MINIMUM ABOVE THE FINISH FLOOR OR GROUND. 11B-307 4.1 GUY BRACES. WHERE A GUY SUPPORT IS USED WITHIN EITHER THE WIDTH OF A CIRCULATION PATH OR 24 INCHES (610 mm) MAXIMUM OUTSIDE OF A CIRCULATION PATH, A VERTICAL GUY BRACE, SIDEWALK GUY OR SIMILAR DEVICE SHALL BE USED TO PREVENT A HAZARD OR AN OVERHEAD OBSTRUCTION. 11B-307.5 REQUIRED CLEAR WIDTH. PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH REQUIRED FOR ACCESSIBLE ROUTES. 68 6 - 2 0 3 2 2'- 3 " - 6 ' - 8 " 305 1'-0" MAX 305 1'-0" MAX 68 6 2' - 3 " M A X 305 X>1'-0" 305 X>1'-0" 20 3 2 6' - 8 " M I N 20 3 2 X> 6 ' - 8 " 68 6 X> 2 ' - 3 " 102 4" MAX 68 6 2' - 3 " M A X 20 3 2 X< 6 ' - 8 " FIGURE 11B-307.4 VERTICAL CLEARANCE FIGURE 11B-307.3 POST-MOUNTED PROTRUDING OBJECTS (b) FIGURE 11B-307.2 LIMITS OF PROTRUDING OBJECTS 11B-308 REACH RANGES 11B-308.1 GENERAL. REACH RANGES SHALL COMPLY WITH SECTION 11B-308. 11B-308.1.1 ELECTRICAL SWITCHES. CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF A ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND VENTILATING EQUIPMENT, SHALL COMPLY WITH SECTION 11B-308 EXCEPT THE LOW REACH SHALL BE MEASURED TO THE BOTTOM OF THE OUTLET BOX AND THE HIGH REACH SHALL BE MEASURED TO THE TOP OF THE OUTLET BOX. 11B-308.1.2 ELECTRICAL RECEPTACLE OUTLETS. ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES SHALL COMPLY WITH SECTION 11B-308 EXCEPT THE LOW REACH SHALL BE MEASURED TO THE BOTTOM OF THE OUTLET BOX AND THE HIGH REACH SHALL BE MEASURED TO THE TOP OF THE OUTLET BOX. 11B-308.2 FORWARD REACH. 11B-308.2.1 UNOBSTRUCTED. WHERE A FORWARD REACH IS UNOBSTRUCTED, THE HIGH FORWARD REACH SHALL BE 48 INCHES (1219 mm) MAXIMUM AND THE LOW FORWARD REACH SHALL BE 15 INCHES (381 mm) MINIMUM ABOVE THE FINISH FLOOR OR GROUND. 11B-308.2.2 OBSTRUCTED HIGH REACH. WHERE A HIGH FORWARD REACH IS OVER AN OBSTRUCTION, THE CLEAR FLOOR SPACE SHALL EXTEND BENEATH THE ELEMENT FOR A DISTANCE NOT LESS THAN THE REQUIRED REACH DEPTH OVER THE OBSTRUCTION. THE HIGH FORWARD REACH SHALL BE 48 INCHES (1219 mm) MAXIMUM. WHERE THE REACH DEPTH IS 20 INCHES (508 mm) MAXIMUM. WHERE THE REACH DEPTH EXCEEDS 20 INCHES (508 mm), THE HIGH FORWARD REACH SHALL BE 44 INCHES (111B mm) MAXIMUM AND THE REACH DEPTH SHALL BE 25 INCHES (635 mm) MAXIMUM. 11B-308.3 SIDE REACH 11B-308.3.1 UNOBSTRUCTED. WHERE A CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE SIDE REACH IS UNOBSTRUCTED, THE HIGH SIDE REACH SHALL BE 48 INCHES (1219 mm) MAXIMUM AND THE LOW SIDE REACH SHALL BE 15 INCHES (381 mm) MINIMUM ABOVE THE FINISH FLOOR OR GROUND. EXCEPTIONS: 1. AN OBSTRUCTION SHALL BE PERMITTED BETWEEN THE CLEAR FLOOR OR GROUND SPACE AND THE ELEMENT WHERE THE DEPTH OF THE OBSTRUCTION IS 10 INCHES (254 mm) MAXIMUM. 2. OPERABLE PARTS OF FUEL DISPENSERS SHALL BE PERMITTED TO BE 54 INCHES (1372 mm) MAXIMUM MEASURED FROM THE SURFACE OF THE VEHICULAR WAY WHERE FUEL DISPENSERS ARE INSTALLED ON EXISTING CURBS. 11B-308.3.2 OBSTRUCTED HIGH REACH. WHERE A CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE HIGH SIDE REACH IS OVER AN OBSTRUCTION, THE HEIGHT OF THE OBSTRUCTION SHALL BE 34 INCHES (864 mm) MAXIMUM AND THE DEPTH OF THE OBSTRUCTION SHALL BE 24 INCHES (610 mm) MAXIMUM. THE HIGH SIDE REACH SHALL BE 48 INCHES (1219 mm) MAXIMUM FOR A REACH DEPTH OF 10 INCHES (254 mm) MAXIMUM WHERE THE REACH DEPTH EXCEEDS 10 INCHES (254 mm) THE HIGH SIDE REACH SHALL BE 46 INCHES (1168 mm) MAXIMUM FOR A REACH DEPTH OF 24 INCHES (610 mm) MAXIMUM. EXCEPTIONS: 1. THE TOP OF WASHING MACHINES AND CLOTHES DRYERS SHALL BE PERMITTED TO BE 36 INCHES (914 mm) MAXIMUM ABOVE THE FINISH FLOOR 2. OPERABLE PARTS OF FUEL DISPENSERS SHALL BE PERMITTED TO BE 54 INCHES (1372 mm) MAXIMUM MEASURED FROM THE SURFACE OF THE VEHICULAR WAY WHERE FUEL DISPENSERS ARE INSTALLED ON EXISTING CURBS. 38 1 1' - 3 " M I N 12 1 9 4' - 0 " M A X 508 1'-8" MAX 12 1 9 4'- 0 " M A X 508-635 1'-8" -2'-1 11 1 8 3'- 8 " M A X 254 10" MAX 38 1 1' - 3 " M I N 12 1 9 4'- 0 " M A X 254 10" MAX 86 4 2'- 1 0 " M A X 12 1 9 4' - 1 0 " M A X FIGURE 11B-308.3.2 OBSTRUCTED HIGH SIDE REACH (A)(B) 254 - 610 >1'-8" - 2'-0" MAX 2' - 1 0 " M A X 86 4 3' - 1 0 " M A X 11 6 8 FIGURE 11B-308.3.1 UNOBSTRUCTED SIDE REACH FIGURE 11B-308.2.2 OBSTRUCTED HIGH FORWARD REACH (A)(B) FIGURE 11B-308.2.1 UNOBSTRUCTED FORWARD REACH 11B-309 OPERABLE PARTS 11B-309.1 GENERAL. OPERABLE PARTS SHALL COMPLY WITH SECTION 11B-309. 11B-309.2 CLEAR FLOOR SPACE. A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH SECTION 11B-305 SHALL BE PROVIDED. 11B-309.3 HEIGHT. OPERABLE PARTS SHALL BE WITHIN ONE OR MORE OF THE REACH RANGES SPECIFIED IN SECTION 11B-308. 11B-309.4 OPERATION. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS (22.2 N) MAXIMUM. EXCEPTION: GAS PUMP NOZZLES AND ELECTRIC VEHICLE CONNECTORS SHALL NOT BE REQUIRED TO PROVIDE OPERABLE PARTS THAT HAVE AN ACTIVATING FORCE OF 5 POUNDS (22.2 N) MAXIMUM. 1DIVISION 2 - APPLICATION 2 DIV. 228 - DEPOSITORIES, MACHINES & MAILBOXES 3DIV. 229 - WINDOWS 4 DIV. 230 - TWO-WAY COMMUNICATION SYSTEMS 5DIV. 247 DETECTABLE WARNINGS 6DIVISION 3 - BUILDIING BLOCKS 7DIV. 302 - FLOOR OR GROUND SURFACE 8DIV. 303 - CHANGES IN LEVEL 9DIV. 304 - TURNING SPACES 10DIV. 305 - CLEAR FLOOR SPACE 11DIV. 306 - KNEE AND TOE CLEARANCE12DIV. 307 - PROTRUDING OBJECTS13DIV. 308 - REACH RANGES 14DIV. 309 - OPERABLE PARTS A0.5b CBC 11B DIV 2 & DIV 3 BUILDING BLOCKS AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 11B-401.1 SCOPE. THE PROVISIONS OF DIVISION 4 SHALL APPLY WHERE REQUIRED BY DIVISION 2 OR WHERE REFERENCED BY A REQUIREMENT IN THIS CHAPTER. 11B-402.1 GENERAL. ACCESSIBLE ROUTES SHALL COMPLY WITH 11B-402. 11B-402.2 COMPONENTS. ACCESSIBLE ROUTES SHALL CONSIST OF ONE OR MORE OF THE FOLLOWING COMPONENTS: WALKING SURFACES WITH A RUNNING SLOPE NOT STEEPER THAN 1:20, DOORWAYS, RAMPS, CURB RAMPS EXCLUDING THE FLARED SIDES, ELEVATORS, AND PLATFORM LIFTS. ALL COMPONENTS OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF DIVISION 4. 11B-401 GENERAL 11B-403.1 GENERAL. WALKING SURFACES THAT ARE A PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH SECTION 11B-403. 11B-403.2 FLOOR OR GROUND SURFACE. FLOOR OR GROUND SURFACES SHALL COMPLY WITH SECTION 11B-302. 11B-403.3 SLOPE. THE RUNNING SLOPE OF WALKING SURFACES SHALL NOT BE STEEPER THAN 1:20. THE CROSS SLOPE OF WALKING SUR-FACES SHALL NOT BE STEEPER THAN 1:48. EXCEPTION: THE RUNNING SLOPE OF SIDEWALKS SHALL NOT EXCEED THE GENERAL GRADE ESTABLISHED FOR THE ADJACENT STREET OR HIGH-WAY. 11B-403.4 CHANGES IN LEVEL. CHANGES IN LEVEL SHALL COMPLY WITH SECTION 11B-303. 11B-403.5 CLEARANCES. WALKING SURFACES SHALL PROVIDE CLEARANCES COMPLYING WITH SECTION 11B-403.5. EXCEPTION: WITHIN EMPLOYEE WORK AREAS, CLEARANCES ON COMMON USE CIRCULATION PATHS SHALL BE PERMITTED TO BE DECREASED BY WORK AREA EQUIPMENT PROVIDED THAT THE DECREASE IS ESSENTIAL TO THE FUNCTION OF THE WORK BEING PERFORMED. 11B-403.5.1 CLEAR WIDTH. EXCEPT AS PROVIDED IN SECTIONS 11B-403.5.2 AND 11B-403.5.3, THE CLEAR WIDTH OF WALKING SURFACES SHALL BE 36 INCHES (914 mm) MINIMUM. EXCEPTIONS: 1. THE CLEAR WIDTH SHALL BE PERMITTED TO BE REDUCED TO 32 INCHES (813 mm) MINIMUM FOR A LENGTH OF 24 INCHES (610 mm) MAXIMUM PROVIDED THAT REDUCED WIDTH SEGMENTS ARE SEPARATED BY SEGMENTS THAT ARE 48 INCHES (1219 mm) LONG MINIMUM AND 36 INCHES (914 mm) WIDE MINIMUM. 2. THE CLEAR WIDTH FOR WALKING SURFACES IN CORRIDORS SERVING AN OCCUPANT LOAD OF 10 OR MORE SHALL BE 44 INCHES (1118 mm) MINIMUM. 3. THE CLEAR WIDTH FOR SIDEWALKS AND WALKS SHALL BE 48 INCHES (1219 mm) MINIMUM. WHEN, BECAUSE OF RIGHT-OF-WAY RESTRICTIONS, NATURAL BARRIERS OR OTHER EXISTING CONDITIONS, THE ENFORCING AGENCY DETERMINES THAT COMPLIANCE WITH THE 48-INCH (1219 mm) CLEAR SIDEWALK WIDTH WOULD CREATE AN UNREASONABLE HARDSHIP, THE CLEAR WIDTH MAY BE REDUCED TO 36 INCHES (914 mm). 4. THE CLEAR WIDTH FOR AISLES SHALL BE 36 INCHES (914 mm) MINIMUM IF SERVING ELEMENTS ON ONLY ONE SIDE, AND 44 INCHES (1118 MM) MINIMUM IF SERVING ELEMENTS ON BOTH SIDES. 5. THE CLEAR WIDTH FOR ACCESSIBLE ROUTES TO ACCESSIBLE TOILET COMPARTMENTS SHALL BE 44 INCHES (1118 mm) EXCEPT FOR DOOR-OPENING WIDTHS AND DOOR SWINGS. 11B-403.5.2 CLEAR WIDTH AT TURN. WHERE THE ACCESSIBLE ROUTE MAKES A 180 DEGREE TURN AROUND AN ELEMENT WHICH IS LESS THAN 48 INCHES (1219 mm) WIDE, CLEAR WIDTH SHALL BE 42 INCHES (1067 mm) MINIMUM APPROACHING THE TURN, 48 INCHES (1219 mm) MINIMUM AT THE TURN AND 42 INCHES (1067 mm) MINIMUM LEAVING THE TURN. EXCEPTION: WHERE THE CLEAR WIDTH AT THE TURN IS 60 INCHES (1524 mm) MINIMUM COMPLIANCE WITH SECTION 11B-403.5.2 SHALL NOT BE REQUIRED. 11B-403.5.3 PASSING SPACES. AN ACCESSIBLE ROUTE WITH A CLEAR WIDTH LESS THAN 60 INCHES (1524 mm) SHALL PROVIDE PASSING SPACES AT INTERVALS OF 200 FEET (60,960 mm) MAXIMUM.PASSING SPACES SHALL BE EITHER: A SPACE 60 INCHES (1524 mm) MINIMUM BY 60 INCHES (1524 mm) MINIMUM; OR, AN INTERSECTION OF TWO WALKING SURFACES PROVIDING A T-SHAPED SPACE COMPLYING WITH SECTION 11B-304.3.2 WHERE THE BASE AND ARMS OF THE T-SHAPED SPACE EXTEND 48 INCHES (1219 mm) MINIMUM BEYOND THE INTERSECTION. 11B-403.6 HANDRAILS. WHERE HANDRAILS ARE PROVIDED ALONG WALKING SURFACES WITH RUNNING SLOPES NOT STEEPER THAN 1:20 THEY SHALL COMPLY WITH SECTION 11B-505. 11B-403.7 CONTINUOUS GRADIENT. ALL WALKS WITH CONTINUOUS GRADIENTS SHALL HAVE RESTING AREAS, 60 INCHES (1524 mm) IN LENGTH, AT INTERVALS OF 400 FEET (121,920 mm) MAXIMUM. THE RESTING AREA SHALL BE AT LEAST AS WIDE AS THE WALK. THE SLOPE OF THE RESTING AREA IN ALL DIRECTIONS SHALL BE 1:48 MAXIMUM. 81 3 2' - 8 " M I N 91 4 3' - 0 " M I N 610 2'-0" MAX 1219 4'-0" MIN 610 2'-0" MAX 81 3 2' - 8 " M I N 91 4 3' - 0 " M I N 12 1 9 4' - 0 " M I N 15 2 4 5'- 0 " M I N 1067 3'-6" MIN 1219 X < 48" 1067 3'-6" MIN 914 3'-0" MIN 1219 X < 48" 914 3'-0" MIN FIGURE 11B-403.5.1 CLEAR WIDTH OF AN ACCESSIBLE ROUTE FIGURE 11B-403.5.2 CLEAR WIDTH AT TURN (a) 180 degree turn (b) 180 degree turn (Exception) 11B-403 WALKING SURFACES 11B-404.1 GENERAL. DOORS, DOORWAYS, AND GATES THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH SECTION 11B-404. EXCEPTIONS: 1. DOORS, DOORWAYS, AND GATES DESIGNED TO BE OPERATED ONLY BY SECURITY PERSONNEL SHALL NOT BE REQUIRED TO COMPLY WITH SECTIONS 11B-404.2.7, 11B-404.2.8, 11B-404.2.9, 11B-404.3.2 AND 11B-404.3.4 THROUGH 11B-404.3.7. A SIGN VISIBLE FROM THE APPROACH SIDE COMPLYING WITH SECTION 11B-703.5 SHALL BE POSTED STATING “ENTRY RESTRICTED AND CONTROLLED BY SECURITY PERSONNEL ”. 2. AT DETENTION AND CORRECTIONAL FACILITIES, DOORS, DOORWAYS, AND GATES DESIGNED TO BE OPERATED ONLY BY SECURITY PERSONNEL SHALL NOT BE REQUIRED TO COMPLY WITH SECTIONS 11B-404.2.7, 11B-404.2.8, 11B-404.2.9, 11B-404.3.2 AND 11B-404.3.4 THROUGH 11B-404.3.7. 11B-404.2 MANUAL DOORS, DOORWAYS, AND MANUAL GATES MANUAL DOORS AND DOORWAYS AND MANUAL GATES INTENDED FOR USER PASSAGE SHALL COMPLY WITH SECTION 11B-404.2. 11B-404.2.1 REVOLVING DOORS, GATES, AND TURNSTILES. REVOLVING DOORS, REVOLVING GATES, AND TURNSTILES SHALL NOT BE PART OF AN ACCESSIBLE ROUTE. 11B-404.2.2 DOUBLE-LEAF DOORS AND GATES. AT LEAST ONE OF THE ACTIVE LEAVES OF DOORWAYS WITH TWO LEAVES SHALL COMPLY WITH SECTIONS 11B-404.2.3 AND 11B-404.2.4. 11B-404.2.3 CLEAR WIDTH. DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES (813 mm) MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24 INCHES (610 mm) DEEP SHALL PROVIDE A CLEAR OPENING OF 36 INCHES (914 mm) MINIMUM. THERE SHALL BE NO PROJECTIONS INTO THE REQUIRED CLEAR OPENING WIDTH LOWER THAN 34 INCHES (864 mm) ABOVE THE FINISH FLOOR OR GROUND. PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES (864 mm) AND 80 INCHES (2032 mm) ABOVE THE FINISH FLOOR OR GROUND SHALL NOT EXCEED 4 INCHES (102 mm). EXCEPTIONS: 1. IN ALTERATIONS, A PROJECTION OF 5/8 INCH (15.9 mm) MAXIMUM INTO THE REQUIRED CLEAR WIDTH SHALL BE PERMITTED FOR THE LATCH SIDE STOP. 2. DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES (1981 mm) MINIMUM ABOVE THE FINISH FLOOR OR GROUND. 11B-404.2.4 MANEUVERING CLEARANCES. MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL COMPLY WITH SECTION 11B-404.2.4. MANEUVERING CLEARANCES SHALL EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED LATCH SIDE OR HINGE SIDE CLEARANCE. EXCEPTION: RESERVED. 11B-404.2.4.1 SWINGING DOORS AND GATES. SWINGING DOORS AND GATES SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 11B-404.2.4.1. 813 2'-8" MIN 813 2'-8" MIN 813 2'-8" MIN 90.0 0 ° (a) hinged door FIGURE 11B-404.2.3 CLEAR WIDTH OF DOORWAYS (b) sliding door (c) folding door TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES TYPE OF USE MINIMUM MANEUVERING CLEARANCE APPROACH DIRECTION DOOR OR GATE SIDE PERPENDICULAR TO DOORWAY PARALLEL TO DOORWAY (beyond latch side unless noted) FROM FRONT PULL 60 INCHES (1524 mm)18 INCHES (457 mm)5 FROM FRONT PUSH 48 INCHES (1219 mm)0 INCHES (0 mm) ¹ FROM HINGE SIDE PULL 60 INCHES (1524 mm)36 INCHES (914 mm) FROM HINGE SIDE PUSH 44 INCHES (1118 mm) ²22 INCHES (559 mm) ³ FROM LATCH SIDE PULL 60 INCHES (1524 mm)24 INCHES (610 mm) FROM LATCH SIDE PUSH 44 INCHES (1118 mm)4 24 INCHES (610 mm) 1. Add 12 inches (305 min) if closer and latch are provided. 2. Add 4 inches (102 min) if closer and latch are provided. 3. Beyond hinge side 4. Add 4 inches (102 min) if closer is provided. 5. Add 6 inches (152mm) at exterior side of exterior doors. 15 2 4 5' - 0 " M I N 457 1'-6" MIN 12 1 9 4' - 0 " M I N 15 2 4 5'- 0 " M I N 914 3'-0" MIN 12 1 9 4' - 0 " M I N 305 1'-0" MIN 11 1 8 3' - 8 " M I N 559 1'-10" MIN 12 1 9 4' - 0 " M I N 559 1'-10" MIN 15 2 4 5' - 0 " M I N 610 2'-0" MIN 610 2'-0" MAX 11 1 8 3' - 8 " M I N 12 1 9 4'- 0 " M I N 610 2'-0" MAX Add 6 inches (152 mm) at exterior side of exterior door. (a) front approach, pull side (b) front approach, push side (c) front approach, push side, door provided with both closer and latch (d) hinge approach, pull side (f) hinge approach, push side (g) hinge approach, push side, door provided with both closer and latch (h) latch approach, pull side (j) latch approach, push side (i) reserved (k) latch approach, push side, door provided with closer (e) reserved FIGURE 11B-404.2.4.1 MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS AND GATES 11B-404.2.4.2 DOORWAYS WITHOUT DOORS OR GATES, SLIDING DOORS, AND FOLDING DOORS. DOORWAYS LESS THAN 36 INCHES (914 MM) WIDE WITHOUT DOORS OR GATES, SLIDING DOORS, OR FOLDING DOORS SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 11B-404.2.4.2. 11B-404.2.4.3 RECESSED DOORS AND GATES. MANEUVERING CLEARANCES FOR FORWARD APPROACH SHALL BE PROVIDED WHEN ANY OBSTRUCTION WITHIN 18 INCHES (457 mm) OF THE LATCH SIDE AT AN INTERIOR DOORWAY, OR WITHIN 24 INCHES (610 mm) OF THE LATCH SIDE OF AN EXTERIOR DOORWAY, PROJECTS MORE THAN 8 INCHES (203 mm) BEYOND THE FACE OF THE DOOR, MEASURED PERPENDICULAR TO THE FACE OF THE DOOR OR GATE. 11B-404.2.4.4 FLOOR OR GROUND SURFACE. FLOOR OR GROUND SURFACE WITHIN REQUIRED MANEUVERING CLEARANCES SHALL COMPLY WITH SECTION 11B-302. CHANGES IN LEVEL ARE NOT PERMITTED. EXCEPTIONS: 1. SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED. 2. CHANGES IN LEVEL AT THRESHOLDS COMPLYING WITH SECTION 11B-404.2.5 SHALL BE PERMITTED. 11B-404.2.5 THRESHOLDS. THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE 1/2 INCH (12.7 mm) HIGH MAXIMUM. RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH SECTIONS 11B-302 AND 11B-303. EXCEPTION: RESERVED. 11B-404.2.6 DOORS IN SERIES AND GATES IN SERIES. THE DISTANCE BETWEEN TWO HINGED OR PIVOTED DOORS IN SERIES AND GATES IN SERIES SHALL BE 48 INCHES (1219 mm MINIMUM PLUS THE WIDTH OF DOORS OR GATES SWINGING INTO THE SPACE. 11B-404.2.7 DOOR AND GATE HARDWARE. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS AND GATES SHALL COMPLY WITH SECTION 11B-309.4. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 INCHES (864 mm) MINIMUM AND 44 INCHES (1118 mm) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. EXCEPTIONS: 1. EXISTING LOCKS SHALL BE PERMITTED IN ANY LOCATION AT EXISTING GLAZED DOORS WITHOUT STILES, EXISTING OVERHEAD ROLLING DOORS OR GRILLES, AND SIMILAR EXISTING DOORS OR GRILLES THAT ARE DESIGNED WITH LOCKS THAT ARE ACTIVATED ONLY AT THE TOP OR BOTTOM RAIL. 2. ACCESS GATES IN BARRIER WALLS AND FENCES PROTECTING POOLS, SPAS, AND HOT TUBS SHALL BE PERMITTED TO HAVE OPERABLE PARTS OF THE RELEASE OF LATCH ON SELF-LATCHING DEVICES AT 54 INCHES (1372 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PROVIDED THE SELF-LATCHING DEVICES ARE NOT ALSO SELF-LOCKING DEVICES AND OPERATED BY MEANS OF A KEY, ELECTRONIC OPENER, OR INTEGRAL COMBINATION LOCK 11B-404.2.8 CLOSING SPEED. DOOR AND GATE CLOSING SPEED SHALL COMPLY WITH SECTION 11B-404.2.8. 11B-404.2.8.1 DOOR CLOSERS AND GATE CLOSERS. DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM. 11B-404.2.8.2 SPRING HINGES. DOOR AND GATE SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70 DEGREES, THE DOOR OR GATE SHALL MOVE TO THE CLOSED POSITION IN 1.5 SECONDS MINIMUM. 11B-404.2.9 DOOR AND GATE OPENING FORCE. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE SHALL BE AS FOLLOWS: 1. INTERIOR HINGED DOORS AND GATES: 5 POUNDS (22.2 n) MAXIMUM. 2. SLIDING OR FOLDING DOORS: 5 POUNDS (22.2 n) MAXIMUM. 3. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS (66.7 n). 4. EXTERIOR HINGED DOORS: 5 POUNDS (22.2 n) MAXIMUM. TABLE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS OR GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING DOORS MINIMUM MANEUVERING CLEARANCE APPROACH DIRECTION PERPENDICULAR TO DOORWAY PARALLEL TO DOORWAY (beyond latch side unless noted) FROM FRONT ¹48 INCHES (1219 mm)18 INCHES (457 mm) FROM SIDE 42 INCHES (1067 mm)0 INCHES (0 mm) FROM POCKET / HINGE SIDE 42 INCHES (1067 mm)22 INCHES (559 mm) ² FROM STOP / LATCH SIDE 42 INCHES (1067 mm) 24 INCHES (610 mm) 1. 2. Doorway with no door only. Beyond pocket / hinge side. 12 1 9 4' - 0 " M I N (a) front approach 10 6 7 3' - 6 " M I N 10 6 7 3' - 6 " M I N 10 6 7 3' - 6 " M I N 610 2'-0" MIN 15 2 4 5' - 0 " M I N 18" MIN AT INTERIOR (457) 24" MIN AT EXTERIOR (610) 20 3 X> 8 " 20 3 X> 8 " 12 1 9 4' - 0 " M I N 12 1 9 4' - 0 " M I N 305 1'-0" MIN 20 3 X> 8 " 1219 4'-0" MIN 1219 4'-0" MIN 559 1'-10" MIN (b) side approach (d) stop or latch approach (c) pocket or hinge approach FIGURE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS (a) pull side (b) push side (c) push side, door provided with both closer and latch FIGURE 11B-404.2.4.3 MANEUVERING CLEARANCE AT RECESSED DOORS AND GATES (a)(b) FIGURE 11B-404.2.6 DOORS IN SERIES AND GATES IN SERIES THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR OR GATE IN A CLOSED POSITION. EXCEPTION: WHEN, AT A SINGLE LOCATION, ONE OF EVERY EIGHT EXTERIOR DOOR LEAFS, OR FRACTION OF EIGHT, IS A POWERED DOOR, OTHER EXTERIOR DOORS AT THE SAME LOCATION, SERVING THE SAME INTERIOR SPACE, MAY HAVE A MAXIMUM OPENING FORCE OF 8.5 POUNDS (37.8 N). THE POWERED LEAF(S) SHALL BE LOCATED CLOSEST TO THE ACCESSIBLE ROUTE. a. POWERED DOORS SHALL COMPLY WITH SECTION 11B-404.3. POWERED DOORS SHALL BE FULLY AUTOMATIC DOORS COMPLYING WITH BUILDERS HARDWARE MANUFACTURERS ’ ASSOCIATION (BHMA) A156.10 OR LOW ENERGY OPERATED DOORS COMPLYING WITH BHMA A156.19. b. POWERED DOORS SERVING A BUILDING OR FACILITY WITH AN OCCUPANCY OF 150 OR MORE SHALL BE PROVIDED WITH A BACK-UP BATTERY OR BACK-UP GENERATOR. THE BACK-UP POWER SOURCE SHALL BE ABLE TO CYCLE THE DOOR A MINIMUM OF 100 CYCLES. c. POWERED DOORS SHALL BE CONTROLLED ON BOTH THE INTERIOR AND EXTERIOR SIDES OF THE DOORS BY SENSING DEVICES, PUSH PLATES, VERTICAL ACTUATION BARS OR OTHER SIMILAR OPERATING DEVICES COMPLYING WITH SECTIONS 11B-304, 11B-305 AND 11B-308. AT EACH LOCATION WHERE PUSH PLATES ARE PROVIDED THERE SHALL BE TWO PUSH PLATES; THE CENTERLINE OF ONE PUSH PLATE SHALL BE 7 INCHES (178 mm) MINIMUM AND 8 INCHES (203 mm) MAXIMUM ABOVE THE FLOOR OR GROUND 11B-404 DOORS, DOORWAYS AND GATES SURFACE AND THE CENTERLINE OF THE SECOND PUSH PLATE SHALL BE 30 INCHES (762 mm) MINIMUM AND 44 INCHES (1118 mm) MAXIMUM ABOVE THE FLOOR OR GROUND SURFACE. EACH PUSH PLATE SHALL BE A MINIMUM OF 4 INCHES (102 mm) DIAMETER OR A MINIMUM OF 4 INCHES BY 4 INCHES (102 mm BY 102 mm) SQUARE AND SHALL DISPLAY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7. AT EACH LOCATION WHERE VERTICAL ACTUATION BARS ARE PROVIDED THE OPERABLE PORTION SHALL BE LOCATED SO THE BOTTOM IS 5 INCHES (127 mm) MAXIMUM ABOVE THE FLOOR OR GROUND SURFACE AND THE TOP IS 35 INCHES (889 mm) MINIMUM ABOVE THE FLOOR OR GROUND SURFACE. THE OPERABLE PORTION OF EACH VERTICAL ACTUATION BAR SHALL BE A MINIMUM OF 2 INCHES (51 mm) WIDE AND SHALL DISPLAY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7. WHERE PUSH PLATES, VERTICAL ACTUATION BARS OR OTHER SIMILAR OPERATING DEVICES ARE PROVIDED, THEY SHALL BE PLACED IN A CONSPICUOUS LOCATION. A LEVEL AND CLEAR FLOOR OR GROUND SPACE FOR FORWARD OR PARALLEL APPROACH COMPLYING WITH SECTION 11B-305 SHALL BE PROVIDED, CENTERED ON THE OPERATING DEVICE. DOORS SHALL NOT SWING INTO THE REQUIRED CLEAR FLOOR OR GROUND SPACE. d. SIGNS IDENTIFYING THE ACCESSIBLE ENTRANCE REQUIRED BY SECTION 11B-216.6 SHALL BE PLACED ON, OR IMMEDIATELY ADJACENT TO, EACH POWERED DOOR. SIGNS SHALL BE PROVIDED IN COMPLIANCE WITH BHMA A156.10 OR BHMA A156.19, AS APPLICABLE. e. IN ADDITION TO THE REQUIREMENTS OF ITEM D, WHERE A POWERED DOOR IS PROVIDED IN BUILDINGS OR FACILITIES CONTAINING ASSEMBLY OCCUPANCIES OF 300 OR MORE, A SIGN DISPLAYING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY MEASURING 6 INCHES BY 6 INCHES (152 mm BY 152 mm), COMPLYING WITH SECTION 11B-703.7, SHALL BE PROVIDED ABOVE THE DOOR ON BOTH THE INTERIOR AND EXTERIOR SIDES OF EACH POWERED DOOR. 11B-404.2.10 DOOR AND GATE SURFACES. SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES (254 mm) OF THE FINISH FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN THESE SURFACES SHALL BE WITHIN 1/16 INCH (1.6 mm) OF THE SAME PLANE AS THE OTHER AND BE FREE OF SHARP OR ABRASIVE EDGES. CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED. EXCEPTIONS: 1. SLIDING DOORS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-404.2.10. 2. TEMPERED GLASS DOORS WITHOUT STILES AND HAVING A BOTTOM RAIL OR SHOE WITH THE TOP LEADING EDGE TAPERED AT 60 DEGREES MINIMUM FROM THE HORIZONTAL SHALL NOT BE REQUIRED TO MEET THE 10 INCH (254 mm) BOTTOM SMOOTH SURFACE HEIGHT REQUIREMENT. 3. DOORS AND GATES THAT DO NOT EXTEND TO WITHIN 10 INCHES (254 mm) OF THE FINISH FLOOR OR GROUND SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-404.2.10. 4. RESERVED. 11B-404.2.11 VISION LIGHTS. DOORS, GATES, AND SIDE LIGHTS ADJACENT TO DOORS OR GATES, CONTAINING ONE OR MORE GLAZING PANELS THAT PERMIT VIEWING THROUGH THE PANELS SHALL HAVE THE BOTTOM OF AT LEAST ONE GLAZED PANEL LOCATED 43 INCHES (1092 mm) MAXIMUM ABOVE THE FINISH FLOOR. EXCEPTION: GLAZING PANELS WITH THE LOWEST PART MORE THAN 66 INCHES (1676 mm) FROM THE FINISH FLOOR OR GROUND SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-404.2.11. 11B-404.3 AUTOMATIC AND POWER-ASSISTED DOORS AND GATES. AUTOMATIC DOORS AND AUTOMATIC GATES SHALL COMPLY WITH SECTION 11B-404.3. FULL-POWERED AUTOMATIC DOORS SHALL COMPLY WITH ANSI/BHMA A156.10. LOW-ENERGY AND POWER-ASSISTED DOORS SHALL COMPLY WITH ANSI/BHMA A156.19. 11B-404.3.1 CLEAR WIDTH. DOORWAYS SHALL PROVIDE A CLEAR OPENING OF 32 INCHES (813 mm) MINIMUM IN POWER-ON AND POWER-OFF MODE. THE MINIMUM CLEAR WIDTH FOR AUTOMATIC DOOR SYSTEMS IN A DOORWAY SHALL PROVIDE A CLEAR, UNOBSTRUCTED OPENING OF 32 INCHES (813 mm) WITH ONE LEAF POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. 11B-404.3.2 MANEUVERING CLEARANCE. CLEARANCES AT POWER-ASSISTED DOORS AND GATES SHALL COMPLY WITH SECTION 11B-404.2.4. CLEARANCES AT AUTOMATIC DOORS AND GATES WITHOUT STANDBY POWER AND SERVING AN ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH SECTION 11B-404.2.4. EXCEPTION: WHERE AUTOMATIC DOORS AND GATES REMAIN OPEN IN THE POWER-OFF CONDITION, COMPLIANCE WITH SECTION 11B-404.2.4 SHALL NOT BE REQUIRED. 11B-404.3.3 THRESHOLDS. THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH SECTION 11B-404.2.5. 11B-404.3.4 DOORS IN SERIES AND GATES IN SERIES. DOORS IN SERIES AND GATES IN SERIES SHALL COMPLY WITH SECTION 11B-404.2.6. 11B-404.3.5 CONTROLS. MANUALLY OPERATED CONTROLS SHALL COMPLY WITH SECTION 11B-309. THE CLEAR FLOOR SPACE ADJA-CENT TO THE CONTROL SHALL BE LOCATED BEYOND THE ARC OF THE DOOR SWING. 11B-404.3.6 BREAK OUT OPENING. WHERE DOORS AND GATES WITHOUT STANDBY POWER ARE A PART OF A MEANS OF EGRESS, THE CLEAR BREAK OUT OPENING AT SWINGING OR SLIDING DOORS AND GATES SHALL BE 32 INCHES (813 mm) MINIMUM WHEN OPERATED IN EMERGENCY MODE. EXCEPTION: WHERE MANUAL SWINGING DOORS AND GATES COMPLY WITH SECTION 11B-404.2 AND SERVE THE SAME MEANS OF EGRESS COMPLIANCE WITH SECTION 11B-404.3.6 SHALL NOT BE REQUIRED. 11B-404.3.7 REVOLVING DOORS, REVOLVING GATES, AND TURNSTILES. REVOLVING DOORS, REVOLVING GATES, AND TURN-STILES SHALL NOT BE PART OF AN ACCESSIBLE ROUTE. 11B-405.1 GENERAL. RAMPS ON ACCESSIBLE ROUTES SHALL COMPLY WITH SECTION 11B-405. EXCEPTION: IN ASSEMBLY AREAS, AISLE RAMPS ADJACENT TO SEATING AND NOT SERVING ELEMENTS REQUIRED TO BE ON AN ACCESSIBLE ROUTE SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-405. 11B-405.2 SLOPE. RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12. EXCEPTION: RESERVED. 11B-405.3 CROSS SLOPE. CROSS SLOPE OF RAMP RUNS SHALL NOT BE STEEPER THAN 1:48. 11B-405.4 FLOOR OR GROUND SURFACES. FLOOR OR GROUND SURFACES OF RAMP RUNS SHALL COMPLY WITH SECTION 11B-302. CHANGES IN LEVEL OTHER THAN THE RUNNING SLOPE AND CROSS SLOPE ARE NOT PERMITTED ON RAMP RUNS. 11B-405.5 CLEAR WIDTH. THE CLEAR WIDTH OF A RAMP RUN SHALL BE 48 INCHES (1219 mm) MINIMUM. EXCEPTIONS: 1. WITHIN EMPLOYEE WORK AREAS, THE REQUIRED CLEAR WIDTH OF RAMPS THAT ARE A PART OF COMMON USE CIRCULATION PATHS SHALL BE PERMITTED TO BE DECREASED BY WORK AREA EQUIPMENT PROVIDED THAT THE DECREASE IS ESSENTIAL TO THE FUNCTION OF THE WORK BEING PERFORMED. 2. HANDRAILS MAY PROJECT INTO THE REQUIRED CLEAR WIDTH OF THE RAMP AT EACH SIDE 3 1/2 INCHES (89 mm) MAXIMUM AT THE HANDRAIL HEIGHT. 3. THE CLEAR WIDTH OF RAMPS IN RESIDENTIAL USES SERVING AN OCCUPANT LOAD OF FIFTY OR LESS SHALL BE 36 INCHES (914 mm) MINIMUM BETWEEN HANDRAILS. 11B-405.6 RISE. THE RISE FOR ANY RAMP RUN SHALL BE 30 INCHES (762 mm) MAXIMUM. 11B-405.7 LANDINGS. RAMPS SHALL HAVE LANDINGS AT THE TOP AND THE BOTTOM OF EACH RAMP RUN. LANDINGS SHALL COMPLY WITH SECTION 11B-405.7. 11B-405.7.1 SLOPE. LANDINGS SHALL COMPLY WITH SECTION 11B-302. CHANGES IN LEVEL ARE NOT PERMITTED. EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE PER-MITTED.11B-405.7.2 WIDTH. THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE WIDEST RAMP RUN LEADING TO THE LANDING. 11B-405.7.2.1:TOP LANDINGS SHALL BE 60 INCHES (1524 mm) WIDE MINIMUM. 11B-405.7.3 LENGTH. THE LANDING CLEAR LENGTH SHALL BE 60 INCHES (1524 mm) LONG MINIMUM. 11B-405.7.3.1:BOTTOM LANDINGS SHALL EXTEND 72 INCHES (1829 mm) MINIMUM IN THE DIRECTION OF RAMP RUN. 11B-405.7.4 CHANGE IN DIRECTION. RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT LANDINGS SHALL HAVE A CLEAR LANDING 60 INCHES (1525 mm) MINIMUM BY 72 INCHES (1829 mm) MINIMUM IN THE DIRECTION OF DOWNWARD TRAVEL FROM THE UPPER RAMP RUN. 11B-405.7.5 DOORWAYS. WHERE DOORWAYS ARE LOCATED ADJACENT TO A RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY SECTIONS 11B-404.2.4 AND 11B-404.3.2 SHALL BE PERMITTED TO OVERLAP THE REQUIRED LANDING AREA. DOORS, WHEN FULLY OPEN, SHALL NOT REDUCE THE REQUIRED RAMP LANDING WIDTH BY MORE THAN 3 INCHES (76 MM). DOORS, IN ANY POSITION, SHALL NOT REDUCE THE MINIMUM DIMENSION OF THE RAMP LANDING TO LESS THAN 42 INCHES (1067 mm). 11B-405.8 HANDRAILS. RAMP RUNS SHALL HAVE HANDRAILS COMPLYING WITH SECTION 11B-505. EXCEPTIONS: 1. RESERVED. 2. RESERVED. 3. CURB RAMPS DO NOT REQUIRE HANDRAILS. 4. AT DOOR LANDINGS, HANDRAILS ARE NOT REQUIRED ON RAMP RUNS LESS THAN 6 INCHES (152 mm) IN RISE OR 72 INCHES (1829 mm) IN LENGTH. 11B-405.9 EDGE PROTECTION. EDGE PROTECTION COMPLYING WITH SECTION 11B-405.9.2 SHALL BE PROVIDED ON EACH SIDE OF RAMP RUNS AND AT EACH SIDE OF RAMP LANDINGS. EXCEPTIONS: 1. EDGE PROTECTION SHALL NOT BE REQUIRED ON RAMPS THAT ARE NOT REQUIRED TO HAVE HANDRAILS AND HAVE SIDES COMPLYING WITH SECTION 11B-406.2.2. 2. EDGE PROTECTION SHALL NOT BE REQUIRED ON THE SIDES OF RAMP LANDINGS SERVING AN ADJOINING RAMP RUN OR STAIRWAY. 3. EDGE PROTECTION SHALL NOT BE REQUIRED ON THE SIDES OF RAMP LANDINGS HAVING A VERTICAL DROP-OFF OF 1/2 INCH (12.7 mm) MAXIMUM WITHIN 10 INCHES (254 mm) HORIZONTALLY OF THE MINIMUM LANDING AREA SPECIFIED IN SECTION 11B-405.7. 11B-405.9.1 RESERVED. 11B-405.9.2 CURB OR BARRIER. A CURB OR BARRIER SHALL BE PROVIDED THAT PREVENTS THE PASSAGE OF A 4-INCH (102 mm) DIAMETER SPHERE, WHERE ANY PORTION OF THE SPHERE IS WITHIN 4 INCHES (102 mm) OF THE FINISH FLOOR OR GROUND SURFACE. TO PREVENT WHEEL ENTRAPMENT, THE CURB OR BARRIER SHALL PROVIDE A CONTINUOUS AND UNINTERRUPTED BARRIER ALONG THE LENGTH OF THE RAMP. 11B-405.10 WET CONDITIONS. LANDINGS SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO PREVENT THE ACCUMULATION OF WATER. 15 2 4 5' - 0 " M I N 1524 5'-0" MIN 18 2 9 6' - 0 " M I N 1524 5'-0" MIN 1524 5'-0" MIN 1829 6'-0" MIN at l e a s t a s wi d e a s r a m p r u n bottom landing ramp run landing la n d i n g ramp run ra m p r u n to p l a n d i n g (a) straight (b) change in direction (c) top landing FIGURE 11B-405.7 RAMP LANDINGS FIGURE 11B-405.9.2 CURB OR BARRIER EDGE PROTECTION 11 B-405 RAMPS 10 2 X < 4 " GENERAL. CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS ON ACCESSIBLE ROUTES SHALL COMPLY WITH SECTION 11B-406. CURB RAMPS MAY BE PERPENDICULAR, PARALLEL, OR A COMBINATION OF PERPENDICULAR AND PARALLEL. 11B-406.1 11B-406 CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS 11B-406.1.1 11B-406.1.2 11B-406.1.3 11B-406.1.4 11B-406.2 11B-406.2.1 11B-406.2.2 PERPENDICULAR CURB RAMPS. PERPENDICULAR CURB RAMPS SHALL COMPLY WITH SECTION 11B-406.2. PARALLECOL CURB RAMPS. PARALLEL CURB RAMPS SHALL COMPLY WITH SECTION 11B-406.3. BLENDED TRANSITIONS. BLENDED TRANSITIONS SHALL COMPLY WITH SECTION 11B-406.4. ISLANDS. ISLANDS SHALL COMPLY WITH SECTION 11B-406.6. PERPENDICULAR CURB RAMPS. PERPENDICULAR CURB RAMPS SHALL COMPLY WITH SECTIONS 11B-406.2 AND 11B-406.5. SLOPE. RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12. SIDES OF CURB RAMPS. WHERE PROVIDED, CURB RAMP FLARES SHALL NOT BE STEEPER THAN 1:10. flared sides 1:10 max slope slopeslope FIGURE 11B-406.2.2 SIDES OF CURB RAMPS 11B-406.3 PARALLEL CURB RAMPS. PARALLEL CURB RAMPS SHALL COMPLY WITH SECTIONS 11B-406.3 AND 11B-406.5. 11B-406.3.1 SLOPE. THE RUNNING SLOPE OF THE CURB RAMP SEGMENTS SHALL BE IN-LINE WITH THE DIRECTION OF SIDEWALK TRAVEL. RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12. 11B-406.3.2 TURNING SPACE. A TURNING SPACE 48 INCHES (1219 mm) MINIMUM BY 48 INCHES (1219 mm) MINIMUM SHALL BE PROVIDED AT THE BOTTOM OF THE CURB RAMP. THE SLOPE OF THE TURNING SPACE IN ALL DIRECTIONS SHALL BE 1:48 MAXIMUM. 11B-406.4 BLENDED TRANSITIONS. BLENDED TRANSITIONS SHALL COMPLY WITH SECTIONS 11B-406.4 AND 11B-406.5. 11B-406.4.1 SLOPE. BLENDED TRANSITIONS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:20. 11B-406.5 COMMON REQUIREMENTS. CURB RAMPS AND BLENDED TRANSITIONS SHALL COMPLY WITH SECTION 11B-406.5. 11B-406.5.1 LOCATION. CURB RAMPS AND THE FLARED SIDES OF CURB RAMPS SHALL BE LOCATED SO THAT THEY DO NOT PROJECT INTO VEHICULAR TRAFFIC LANES, PARKING SPACES, OR PARKING ACCESS AISLES. CURB RAMPS AT MARKED CROSSINGS SHALL BE WHOLLY CONTAINED WITHIN THE MARKINGS, EXCLUDING ANY FLARED SIDES. EXCEPTION: DIAGONAL CURB RAMPS SHALL COMPLY WITH SECTION 11B-406.5.9. 11B-406.5.2 WIDTH. THE CLEAR WIDTH OF CURB RAMP RUNS (EXCLUDING ANY FLARED SIDES), BLENDED TRANSITIONS, AND TURNING SPACES SHALL BE 48 INCHES (1219 MM) MINIMUM. 11B-406.5.3 LANDINGS. LANDINGS SHALL BE PROVIDED AT THE TOPS OF CURB RAMPS AND BLENDED TRANSITIONS. THE LANDING CLEAR LENGTH SHALL BE 48 INCHES (1219 MM) MINIMUM. THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE CURB RAMP, EXCLUDING ANY FLARED SIDES, OR THE BLENDED TRANSITION LEADING TO THE LANDING. THE SLOPE OF THE LANDING IN ALL DIRECTIONS SHALL BE 1:48 MAXIMUM. EXCEPTION: PARALLEL CURB RAMPS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-406.5.3. 11B-406.5.4 FLOOR OR GROUND SURFACES. FLOOR OR GROUND SURFACES OF CURB RAMPS AND BLENDED TRANSITIONS SHALL COMPLY WITH SECTION 11B-405.4. 11B-406.5.5 WET CONDITIONS. CURB RAMPS AND BLENDED TRANSITIONS SHALL COMPLY WITH SECTION 11B-405.10. 11B-406.5.6 GRADE BREAKS. GRADE BREAKS AT THE TOP AND BOTTOM OF CURB RAMP RUNS SHALL BE PERPENDICULAR TO THE DIRECTION OF THE RAMP RUN. GRADE BREAKS SHALL NOT BE PERMITTED ON THE SURFACE OF RAMP RUNS AND TURNING SPACES. SURFACE SLOPES THAT MEET AT GRADE BREAKS SHALL BE FLUSH. 11B-406.5.7 CROSS SLOPE. THE CROSS SLOPE OF CURB RAMPS AND BLENDED TRANSITIONS SHALL BE 1:48 MAXIMUM. 11B-406.5.8 COUNTER SLOPE. COUNTER SLOPES OF ADJOINING GUTTERS AND ROAD SURFACES IMMEDIATELY ADJACENT TO AND WITHIN 24 INCHES (610 mm) OF THE CURB RAMP SHALL NOT BE STEEPER THAN 1:20. THE ADJACENT SURFACES AT TRANSITIONS AT CURB RAMPS TO WALKS, GUTTERS, AND STREETS SHALL BE AT THE SAME LEVEL. 11B-406.5.9 CLEAR SPACE AT DIAGONAL CURB RAMPS. THE BOTTOM OF DIAGONAL CURB RAMPS SHALL HAVE A CLEAR SPACE 48 INCHES (1219 mm) MINIMUM OUTSIDE ACTIVE TRAFFIC LANES OF THE ROADWAY. DIAGONAL CURB RAMPS PROVIDED AT MARKED CROSSINGS SHALL PROVIDE THE 48 INCHES (1219 mm) MINIMUM CLEAR SPACE WITHIN THE MARKINGS. 11B-406.5.10 DIAGONAL CURB RAMPS. DIAGONAL OR CORNER TYPE CURB RAMPS WITH RETURNED CURBS OR OTHER WELL-DEFINED EDGES SHALL HAVE THE EDGES PARALLEL TO THE DIRECTION OF PEDESTRIAN FLOW. DIAGONAL CURB RAMPS WITH FLARED SIDES SHALL HAVE A SEGMENT OF CURB 24 INCHES (610 mm) LONG MINIMUM LOCATED ON EACH SIDE OF THE CURB RAMP AND WITHIN THE MARKED CROSSING. 1219 4'-0" MIN 12 1 9 4' - 0 " M I N FIGURE 11B-406.3.2 PARALLEL CURB RAMPS FIGURE 11B-406.5.3 LANDINGS AT THE TOP OF CURB RAMPS AT LEAST AS WIDE AS CURB RAMP 12 1 9 4' - 0 " M I N curb ramp slopeadjoining surface maximum slope 1 20 FIGURE 11B-406.5.7 COUNTER SLOPE OF SURFACES ADJACENT TO CURB RAMPS 6 1 0 2 ' - 0 " M I N 61 0 2'- 0 " M I N 12 1 9 4' - 0 " M I N FIGURE 11B-406.5.10 DIAGONAL OR CORNER TYPE CURB RAMPS 11B-406.5.11 RESERVED. 11B-406.5.12 DETECTABLE WARNINGS. CURB RAMPS AND BLENDED TRANSITIONS SHALL HAVE DETECTABLE WARNINGS COM-PLYING WITH SECTION 11B-705. 11B-406.6 ISLANDS. RAISED ISLANDS IN CROSSINGS SHALL BE CUT THROUGH LEVEL WITH THE STREET OR HAVE CURB RAMPS AT BOTH THE CLEAR WIDTH OF THE ACCESSIBLE ROUTE AT ISLANDS SHALL BE 60 INCHES (1524 MM) WIDE MINIMUM. WHERE CURB RAMPS ARE PROVIDED, THEY SHALL COMPLY WITH SECTION 11B-406. LANDINGS COMPLYING WITH SECTION 11B-406.5.3 AND THE ACCESSIBLE ROUTE SHALL BE PERMITTED TO OVERLAP. ISLANDS SHALL HAVE DETECTABLE WARNINGS COMPLYING WITH SECTION 11B-705. 1524 5'-0" MIN 12 1 9 4' - 0 " M I N 1524 5'-0" MIN (a) cut through at island (b) curb ramp at island FIGURE 11B-406.6 ISLANDS IN CROSSINGS 1DIVISION 4 - ACCESSIBLE ROUTE 2DIV. 403 - WALKING SURFACES 3DIV. 404 - DOORS, DOORWAYS AND GATES4DIV. 405 - RAMPS5 DIV. 406 - CURB RAMPS TRANSITION & ISLANDS A0.5c CBC 11B DIV 4 ACCESSIBLE ROUTES AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 DIVISION 5: GENERAL SITE AND BUILDING ELEMENTS 11B-501 GENERAL 11B-501.1 SCOPE. THE PROVISIONS OF DIVISION 5 SHALL APPLY WHERE REQUIRED BY DIVISION 2 OR WHERE REFERENCED BY A REQUIREMENT IN THIS CHAPTER. 11B-502.1 GENERAL. CAR AND VAN PARKING SPACES SHALL COMPLY WITH SECTION 11B-502. WHERE PARKING SPACES ARE MARKED WITH LINES, WIDTH MEASUREMENTS OF PARKING SPACES AND ACCESS AISLES SHALL BE MADE FROM THE CENTERLINE OF THE MARKINGS. 11B-502 PARKING SPACES EXCEPTION: WHERE PARKING SPACES OR ACCESS AISLES ARE NOT ADJACENT TO ANOTHER PARKING SPACE OR ACCESS AISLE, MEASUREMENTS SHALL BE PERMITTED TO INCLUDE THE FULL WIDTH OF THE LINE DEFINING THE PARKING SPACE OR ACCESS AISLE. 11B-502.2 VEHICLE SPACES. CAR AND VAN PARKING SPACES SHALL BE 216 INCHES (5486 MM) LONG MINIMUM. CAR PARKING SPACES SHALL BE 108 INCHES (2743 MM) WIDE MINIMUM AND VAN PARKING SPACES SHALL BE 144 INCHES (3658 MM) WIDE MINIMUM, SHALL BE MARKED TO DEFINE THE WIDTH, AND SHALL HAVE AN ADJACENT ACCESS AISLE COMPLYING WITH SECTION 11B-502.3. EXCEPTION: VAN PARKING SPACES SHALL BE PERMITTED TO BE 108 INCHES (2743 MM) WIDE MINIMUM WHERE THE ACCESS AISLE IS 96 INCHES (2438 MM) WIDE MINIMUM. 11B-502.3 ACCESS AISLE. ACCESS AISLES SERVING PARKING SPACES SHALL COMPLY WITH SECTION 11B-502.3. ACCESS AISLES SHALL ADJOIN AN ACCESSIBLE ROUTE. TWO PARKING SPACES SHALL BE PER-MITTED TO SHARE A COMMON ACCESS AISLE. 11B-502.3.1 WIDTH. ACCESS AISLES SERVING CAR AND VAN PARKING SPACES SHALL BE 60 INCHES (1524 MM) WIDE MINIMUM. 11B-502.3.2 LENGTH. ACCESS AISLES SHALL EXTEND THE FULL REQUIRED LENGTH OF THE PARKING SPACES THEY SERVE. 11B-502.3.3 MARKING. ACCESS AISLES SHALL BE MARKED WITH A BLUE PAINTED BORDERLINE AROUND THEIR PERIMETER. THE AREA WITHIN THE BLUE BORDERLINES SHALL BE MARKED WITH HATCHED LINES A MAXIMUM OF 36 INCHES (914 MM) ON CENTER IN A COLOR CONTRASTING WITH THAT OF THE AISLE SURFACE, PREFERABLY BLUE OR WHITE. THE WORDS "NO PARKING" SHALL BE PAINTED ON THE SURFACE WITHIN EACH ACCESS AISLE IN WHITE LETTERS A MINIMUM OF 12 INCHES (305 MM) IN HEIGHT AND LOCATED TO BE VISIBLE FROM THE ADJACENT VEHICULAR WAY. ACCESS AISLE MARKINGS MAY EXTEND BEYOND THE MINIMUM REQUIRED LENGTH. 11B-502.3.4 LOCATION. ACCESS AISLES SHALL NOT OVERLAP THE VEHICULAR WAY. ACCESS AISLES SHALL BE PERMITTED TO BE PLACED ON EITHER SIDE OF THE PARKING SPACE EXCEPT FOR VAN PARKING SPACES WHICH SHALL HAVE ACCESS AISLES LOCATED ON THE PASSENGER SIDE OF THE PARKING SPACES. 11B-502.4 FLOOR OR GROUND SURFACES. PARKING SPACES AND ACCESS AISLES SERVING THEM SHALL COMPLY WITH SECTION 11B-302. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE PARKING SPACES THEY SERVE. CHANGES IN LEVEL ARE NOT PERMITTED. EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED. 11B-502.5 VERTICAL CLEARANCE. PARKING SPACES, ACCESS AISLES AND VEHICULAR ROUTES SERVING THEM SHALL PROVIDE A VERTICAL CLEARANCE OF 98 INCHES (2489 MM) MINIMUM. EXCEPTION: IN EXISTING MULTISTORY PARKING FACILITIES, CAR PARKING SPACES, ACCESS AISLES AND VEHICULAR ROUTES SERVING THEM SHALL PROVIDE A VERTICAL CLEARANCE OF 80 INCHES (2032 MM) MINIMUM. EXISTING VERTICAL CLEARANCE IN EXCESS OF 80 INCHES (2032 MM) AND LESS THAN 98 INCHES (2489 MM) SHALL BE MAINTAINED. THIS EXCEPTION SHALL NOT APPLY TO VAN PARKING SPACES, ACCESS AISLES, OR VEHICULAR ROUTES SERVING THEM. 11B-502.6 IDENTIFICATION. PARKING SPACE IDENTIFICATION SIGNS SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COM-PLYING WITH SECTION 11B-703.7.2.1 IN WHITE ON A BLUE BACK-GROUND. SIGNS IDENTIFYING VAN PARKING SPACES SHALL CONTAIN ADDITIONAL LANGUAGE OR AN ADDITIONAL SIGN WITH THE DESIGNATION “VAN ACCESSIBLE”. SIGNS SHALL BE 60 INCHES (1524 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE MEASURED TO THE BOTTOM OF THE SIGN. EXCEPTION: SIGNS LOCATED WITHIN A CIRCULATION PATH SHALL BE A MINIMUM OF 80 INCHES (2032 MM) ABOVE THE FINISH FLOOR OR GROUND SURFACE MEASURED TO THE BOTTOM OF THE SIGN. 11B-502.6.1 FINISH AND SIZE. PARKING IDENTIFICATION SIGNS SHALL BE REFLECTORIZED WITH A MINIMUM AREA OF 70 SQUARE INCHES (45,161 MM 2). 11B-502.6.2 MINIMUM FINE. ADDITIONAL LANGUAGE OR AN ADDITIONAL SIGN BELOW THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL STATE “MINIMUM FINE $250 ”. 11B-502.6.3 LOCATION. A PARKING SPACE IDENTIFICATION SIGN SHALL BE VISIBLE FROM EACH PARKING SPACE. SIGNS SHALL BE PERMANENTLY POSTED EITHER IMMEDIATELY ADJACENT TO THE PARKING SPACE OR WITHIN THE PROJECTED PARKING SPACE WIDTH AT THE HEAD END OF THE PARKING SPACE. SIGNS MAY ALSO BE PERMANENTLY POSTED ON A WALL AT THE INTERIOR END OF THE PARKING SPACE. 11B-502.6.4 MARKING. EACH ACCESSIBLE CAR AND VAN SPACE SHALL HAVE SURFACE IDENTIFICATION COMPLYING WITH EITHER SECTION 11B-502.6.4.1 OR 11B-502.6.4.2. 11B-502.6.4.1 THE PARKING SPACE SHALL BE MARKED WITH AN INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1 IN WHITE ON A BLUE BACKGROUND A MINIMUM 36 INCHES WIDE BY 36 INCHES HIGH (914 MM BY 914 MM). THE CENTERLINE OF THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE A MAXIMUM OF 6 INCHES (152 MM) FROM THE CENTERLINE OF THE PARKING SPACE, ITS SIDES PARALLEL TO THE LENGTH OF THE PARKING SPACE AND ITS LOWER CORNER AT, OR LOWER SIDE ALIGNED WITH, THE END OF THE PARKING SPACE LENGTH. 11B-502.6.4.2 THE PARKING SPACE SHALL BE OUTLINED IN BLUE OR PAINTED BLUE AND SHALL BE MARKED WITH AN INTER-NATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1 A MINIMUM 36 INCHES WIDE BY 36 INCHES HIGH (914 MM BY 914 MM) IN WHITE OR A SUITABLE CONTRASTING COLOR. THE CENTERLINE OF THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE A MAXIMUM OF 6 INCHES (152 MM) FROM THE CENTERLINE OF THE PARKING SPACE, ITS SIDES PARALLEL TO THE LENGTH OF THE PARKING SPACE AND ITS LOWER CORNER AT, OR LOWER SIDE ALIGNED WITH, THE END OF THE PARKING SPACE. 11B-502.7 RELATIONSHIP TO ACCESSIBLE ROUTES. PARKING SPACES AND ACCESS AISLES SHALL BE DESIGNED SO THAT CARS AND VANS, WHEN PARKED, CANNOT OBSTRUCT THE REQUIRED CLEAR WIDTH OF ADJACENT ACCESSIBLE ROUTES. 11B-502.7.1 ARRANGEMENT. PARKING SPACES AND ACCESS AISLES SHALL BE DESIGNED SO THAT PERSONS USING THEM ARE NOT REQUIRED TO TRAVEL BEHIND PARKING SPACES OTHER THAN TO PASS BEHIND THE PARKING SPACE IN WHICH THEY PARKED. 11B-502.7.2 WHEEL STOPS. A CURB OR WHEEL STOP SHALL BE PROVIDED IF REQUIRED TO PREVENT ENCROACHMENT OF VEHICLES OVER THE REQUIRED CLEAR WIDTH OF ADJACENT ACCESSIBLE ROUTES. 11B-502.8 ADDITIONAL SIGNS. AN ADDITIONAL SIGN SHALL BE POSTED EITHER; 1) IN A CONSPICUOUS PLACE AT EACH ENTRANCE TO AN OFF-STREET PARKING FACILITY OR 2) IMMEDIATELY ADJACENT TO ON-SITE ACCESSIBLE PARKING AND VISIBLE FROM EACH PARKING SPACE. 11B-502.8.1 SIZE. THE ADDITIONAL SIGN SHALL NOT BE LESS THAN 17 INCHES (432 MM) WIDE BY 22 INCHES (559 MM) HIGH. 11B-502.8.2 LETTERING. THE ADDITIONAL SIGN SHALL CLEARLY STATE IN LETTERS WITH A MINIMUM HEIGHT OF 1 INCH (25 MM) THE FOLLOWING: “UNAUTHORIZED” VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER ’S EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT: _________________________ OR BY TELEPHONING _______________________." BLANK SPACES SHALL BE FILLED IN WITH APPROPRIATE INFORMATION AS A PERMANENT PART OF THE SIGN. 5'-0" MIN 1524 fu l l r e q u i r e d l e n g t h o f p a r k i n g s p a c e 18 ' - 0 " M I N 54 8 6 9'-0" MIN 2743 9'-0" MIN 2743 f u l l r e q u i r e d l e n g t h o f p a r k i n g s p a c e f u l l r e q u i r e d l e n g t h o f p a r k i n g s p a c e 5'-0" M I N 1524 1 8 ' - 0 " M I N 5 4 8 6 1 8 ' - 0 " M I N 5 4 8 6 12'-0" M I N 3658 9'-0" M I N 2743 identification sign international symbol of accessibility 36 inches (914 mm) by 36 inches (914 mm ) min access aisle blue stripe hatches lines at 36 inches (914 mm) on center max optical extension of acces aisle markingwhite lettering 12 inches (305 mm) min height EQ EQ 3'-0" MAX 914 EQ EQ international symbol of accessibility 36 inches (914 mm) by 36 inches (914 mm ) min identification sign access aisle blue stripe hatches lines at 36 inches (914 mm) on center max white lettering 12 inches (305 mm) min height NO PARKING NO PARKI N G NO PARK I N G CAR VAN NO PARKING CARVAN CAR VAN NO PARK I N G CARVAN NO PARKING (b) angled parking FIGURE 11B-502.3 PARKING SPACE ACCESS AISLE (a) perpendicular parking (b) angled parking FIGURE 11B-502.2 VEHICLE PARKING SPACES (a) perpendicular parking (a) perpendicular parking (b) angled parking FIGURE 11B-502.3.3 ANGLED AND PERPENDICULAR PARKING IDENTIFICATION 11B-503 PASSENGER DROP-OFF AND LOADING ZONES 11B-503.1 GENERAL. PASSENGER DROP-OFF AND LOADING ZONES SHALL COMPLY WITH SECTION 11B-503. 11B-503.2 VEHICLE PULL-UP SPACE. PASSENGER DROP-OFF AND LOADING ZONES SHALL PROVIDE A VEHICULAR PULL-UP SPACE 96 INCHES (2438 MM) WIDE MINIMUM AND 20 FEET (6096 MM) LONG MINIMUM. 11B-503.3 ACCESS AISLE. PASSENGER DROP-OFF AND LOADING ZONES SHALL PROVIDE ACCESS AISLES COMPLYING WITH SECTION 11B-503 ADJACENT AND PARALLEL TO THE VEHICLE PULL-UP SPACE. ACCESS AISLES SHALL ADJOIN AN ACCESSIBLE ROUTE AND SHALL NOT OVERLAP THE VEHICULAR WAY. 11B-503.3.1 WIDTH. ACCESS AISLES SERVING VEHICLE PULL-UP SPACES SHALL BE 60 INCHES (1524 MM) WIDE MINIMUM. 11B-503.3.2 LENGTH. ACCESS AISLES SHALL EXTEND THE FULL LENGTH OF THE VEHICLE PULL-UP SPACES THEY SERVE. 11B-503.3.3 MARKING. ACCESS AISLES SHALL BE MARKED WITH A PAINTED BORDERLINE AROUND THEIR PERIMETER. THE AREA WITHIN THE BORDERLINES SHALL BE MARKED WITH HATCHED LINES A MAXIMUM OF 36 INCHES (914 MM) ON CENTER IN A COLOR CONTRASTING WITH THAT OF THE AISLE SURFACE. 11B-503.4 FLOOR AND GROUND SURFACES. VEHICLE PULL-UP SPACES AND ACCESS AISLES SERVING THEM SHALL COMPLY WITH SECTION 11B-302. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE VEHICLE PULL-UP SPACE THEY SERVE. CHANGES IN LEVEL ARE NOT PERMITTED. EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED. 11B-503.5 VERTICAL CLEARANCE. VEHICLE PULL-UP SPACES, ACCESS AISLES SERVING THEM, AND A VEHICULAR ROUTE FROM AN ENTRANCE TO THE PASSENGER DROP-OFF AND LOADING ZONE AND FROM THE PASSENGER DROP-OFF AND LOADING ZONE TO A VEHICULAR EXIT SHALL PROVIDE A VERTICAL CLEARANCE OF 114 INCHES (2896 MM) MINIMUM. curb line access aisle area to be marked vehicle pull- up space 20'-0" MIN 6096 5' - 0 " M I N 15 2 4 8'- 0 " M I N 24 3 8 full length of vehicle pull-up space FIGURE 11B-503.3 PASSENGER DROP-OFF AND LOADING ZONE ACCESS AISLE 11B-505 HANDRAILS 11B-505.1 GENERAL. HANDRAILS PROVIDED ALONG WALKING SURFACES COMPLYING WITH SECTION 11B-403, REQUIRED AT RAMPS COMPLYING WITH SECTION 11B-405, AND REQUIRED AT STAIRS COMPLYING WITH SECTION 11B-504 SHALL COMPLY WITH SECTION 11B-505. 11B-505.2 WHERE REQUIRED. HANDRAILS SHALL BE PROVIDED ON BOTH SIDES OF STAIRS AND RAMPS. EXCEPTIONS: 1. IN ASSEMBLY AREAS, HANDRAILS SHALL NOT BE REQUIRED ON BOTH SIDES OF AISLE RAMPS WHERE A HANDRAIL IS PROVIDED AT EITHER SIDE OR WITHIN THE AISLE WIDTH. 2. CURB RAMPS DO NOT REQUIRE HANDRAILS. 3. AT DOOR LANDINGS, HANDRAILS ARE NOT REQUIRED WHEN THE RAMP RUN IS LESS THAN 6 INCHES (152 mm) IN RISE OR 72 INCHES (1829 mm) IN LENGTH. 11B-505.2.1 ORIENTATION. THE ORIENTATION OF AT LEAST ONE HANDRAIL SHALL BE IN THE DIRECTION OF THE STAIR RUN, PERPENDICULAR TO THE DIRECTION OF THE STAIR NOSING, AND SHALL NOT REDUCE THE MINIMUM REQUIRED WIDTH OF THE STAIR. 11B-505.3 CONTINUITY. HANDRAILS SHALL BE CONTINUOUS WITHIN THE FULL LENGTH OF EACH STAIR FLIGHT OR RAMP RUN. INSIDE HANDRAILS ON SWITCHBACK OR DOGLEG STAIRS AND RAMPS SHALL BE CONTINUOUS BETWEEN FLIGHTS OR RUNS. EXCEPTION: IN ASSEMBLY AREAS, RAMP HANDRAILS ADJACENT TO SEATING OR WITHIN THE AISLE WIDTH SHALL NOT BE REQUIRED TO BE CONTINUOUS IN AISLES SERVING SEATING. 11B-505.4 HEIGHT. TOP OF GRIPPING SURFACES OF HANDRAILS SHALL BE 34 INCHES (864 mm) MINIMUM AND 38 INCHES (965 mm) MAXIMUM VERTICALLY ABOVE WALKING SURFACES, STAIR NOSINGS, AND RAMP SURFACES. HANDRAILS SHALL BE AT A CONSISTENT HEIGHT ABOVE WALKING SURFACES, STAIR NOSINGS, AND RAMP SURFACES. 11B-505.5 CLEARANCE. CLEARANCE BETWEEN HANDRAIL GRIPPING SURFACES AND ADJACENT SURFACES SHALL BE 1 1/2 INCHES (38 mm) MINIMUM. HANDRAILS MAY BE LOCATED IN A RECESS IF THE RECESS IS 3 INCHES (76 mm) MAXIMUM DEEP AND 18 INCHES (457 mm) MINIMUM CLEAR ABOVE THE TOP OF THE HANDRAIL. 11B-505.6 GRIPPING SURFACE. HANDRAIL GRIPPING SURFACES SHALL BE CONTINUOUS ALONG THEIR LENGTH AND SHALL NOT BE OBSTRUCTED ALONG THEIR TOPS OR SIDES. THE BOTTOMS OF HANDRAIL GRIPPING SURFACES SHALL NOT BE OBSTRUCTED FOR MORE THAN 20 PERCENT OF THEIR LENGTH. WHERE PROVIDED, HORIZONTAL PROJECTIONS SHALL OCCUR 1 1/2 INCHES (38 mm) MINIMUM BELOW THE BOTTOM OF THE HANDRAIL GRIPPING SURFACE. EXCEPTIONS: 1. WHERE HANDRAILS ARE PROVIDED ALONG WALKING SURFACES WITH SLOPES NOT STEEPER THAN 1:20, THE BOTTOMS OF HANDRAIL GRIPPING SURFACES SHALL BE PERMITTED TO BE OBSTRUCTED ALONG THEIR ENTIRE LENGTH WHERE THEY ARE INTEGRAL TO CRASH RAILS OR BUMPER GUARDS. 2. THE DISTANCE BETWEEN HORIZONTAL PROJECTIONS AND THE BOTTOM OF THE GRIPPING SURFACE SHALL BE PERMITTED TO BE REDUCED BY 1/8 INCH (3.2 mm) FOR EACH 1/2 INCH (12.7 mm) OF ADDITIONAL HANDRAIL PERIMETER DIMENSION THAT EXCEEDS 4 INCHES (102 mm). 11B-505.7 CROSS SECTION. HANDRAIL GRIPPING SURFACES SHALL HAVE A CROSS SECTION COMPLYING WITH SECTION 11B-505.7.1 OR 11B-505.7.2. 11B-505.7.1 CIRCULAR CROSS SECTION. HANDRAIL GRIPPING SURFACES WITH A CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF 1 1/4 INCHES (32 mm) MINIMUM AND 2 INCHES (51 mm) MAXIMUM. 11B-505.7.2 NON-CIRCULAR CROSS SECTIONS. HANDRAIL GRIPPING SURFACES WITH A NON-CIRCULAR CROSS SECTION SHALL HAVE A PERIMETER DIMENSION OF 4 INCHES (102 mm) MINIMUM AND 6 1/4 INCHES (159 mm) MAXIMUM, AND A CROSS-SECTION DIMENSION OF 2 1/4 INCHES (57 mm) MAXIMUM. 11B-505.8 SURFACES. HANDRAIL GRIPPING SURFACES AND ANY SURFACES ADJACENT TO THEM SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS AND SHALL HAVE ROUNDED EDGES. 11B-505.9 FITTINGS. HANDRAILS SHALL NOT ROTATE WITHIN THEIR FITTINGS. 11B-505.10 HANDRAIL EXTENSIONS. HANDRAIL GRIPPING SURFACES SHALL EXTEND BEYOND AND IN THE SAME DIRECTION OF STAIR FLIGHTS AND RAMP RUNS IN ACCORDANCE WITH SECTION 11B-505.10. EXCEPTIONS: 1. EXTENSIONS SHALL NOT BE REQUIRED FOR CONTINUOUS HANDRAILS AT THE INSIDE TURN OF SWITCHBACK OR DOGLEG STAIRS AND RAMPS. 2. IN ASSEMBLY AREAS, EXTENSIONS SHALL NOT BE REQUIRED FOR RAMP HANDRAILS IN AISLES SERVING SEATING WHERE THE HANDRAILS ARE DISCONTINUOUS TO PROVIDE ACCESS TO SEATING AND TO PERMIT CROSSOVERS WITHIN AISLES. 3. IN ALTERATIONS, WHERE THE EXTENSION OF THE HANDRAIL IN THE DIRECTION OF STAIR FLIGHT OR RAMP RUN WOULD CREATE A HAZARD, THE EXTENSION OF THE HANDRAIL MAY BE TURNED 90 DEGREES FROM THE DIRECTION OF STAIR FLIGHT OR RAMP RUN. 11B-505.10.1 TOP AND BOTTOM EXTENSION AT RAMPS. RAMP HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING FOR 12 INCHES (305 MM) MINIMUM BEYOND THE TOP AND BOTTOM OF RAMP RUNS. EXTENSIONS SHALL RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT RAMP RUN. 11B-505.10.2 TOP EXTENSION AT STAIRS. AT THE TOP OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING FOR 12 INCHES (305 MM) MINIMUM BEGINNING DIRECTLY ABOVE THE FIRST RISER NOSING. EXTENSIONS SHALL RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT. 11B-505.10.3 BOTTOM EXTENSION AT STAIRS. AT THE BOTTOM OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND AT THE SLOPE OF THE STAIR FLIGHT FOR A HORIZONTAL DISTANCE EQUAL TO ONE TREAD DEPTH BEYOND THE LAST RISER NOSING. THE HORIZONTAL EXTENSION OF A HANDRAIL SHALL BE 12 INCHES (305 MM) LONG MINIMUM AND A HEIGHT EQUAL TO THAT OF THE SLOPING PORTION OF THE HANDRAIL AS MEASURED ABOVE THE STAIR NOSINGS. EXTENSION SHALL RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT. 4" - 6 1/4" perimeter 1 1 / 2 " MA X 38 1 1/2" MAX 38 34 " - 3 8 " 86 4 - 9 6 5 34 " - 3 8 " 86 4 - 9 6 5 34 " - 3 8 " 86 4 - 9 6 5 34 " - 3 8 " 86 4 - 9 6 5 1' - 0" 305 1'-0" plus tread depth min X 1'-0" 305 34 " - 3 8 " 86 4 - 9 6 5 1'-0" 305 1'-0" 305 Note: X = tread depth FIGURE 11B-505.10.3 BOTTOM HANDRAIL EXTENSION AT STAIRS FIGURE 11B-505.10.2 TOP HANDRAIL EXTENSION AT STAIRS FIGURE 11B-505.10.1 TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS FIGURE 11B-505.7.2 HANDRAIL NON-CIRCULAR CROSS SECTION 2 1/ 4 " MAX 57 2 1/4" MAX 57 FIGURE 11B-505.6 HORIZONTAL PROJECTIONS BELOW GRIPPING SURFACE FIGURE 11B-505.5 HANDRAIL CLEARANCE (a) stairs (b) ramps (c) walking surfaces FIGURE 11B-505.4 HANDRAIL HEIGHT (a)(b) 11B-504.1 GENERAL. STAIRS SHALL COMPLY WITH SECTION 11B-504. 11B-504 STAIRWAYS 11B-504.2 TREADS AND RISERS. ALL STEPS ON A FLIGHT OF STAIRS SHALL HAVE UNIFORM RISER HEIGHTS AND UNIFORM TREAD DEPTHS.RISERS SHALL BE 4 INCHES (102 MM) HIGH MINIMUM AND 7 INCHES (178 MM) HIGH MAXIMUM. TREADS SHALL BE 11 INCHES (279 MM) DEEP MINIMUM. EXCEPTION: CURVED STAIRWAYS WITH WINDER TREADS ARE PERMITTED AT STAIRS WHICH ARE NOT PART OF A REQUIRED MEANS OF EGRESS. 11B-504.3 OPEN RISERS. OPEN RISERS ARE NOT PERMITTED. EXCEPTIONS: 1. ON EXTERIOR STAIRWAYS, AN OPENING OF NOT MORE THAN 1/2 INCH (12.7 MM) MAY BE PERMITTED BETWEEN THE BASE OF THE RISER AND THE TREAD. 2. ON EXTERIOR STAIRWAYS, RISERS CONSTRUCTED OF GRATING CONTAINING OPENINGS OF NOT MORE THAN 1/2 INCH (12.7 MM) MAY BE PERMITTED. 11B-504.4 TREAD SURFACE. STAIR TREADS SHALL COMPLY WITH SECTION 11B-302. CHANGES IN LEVEL ARE NOT PERMITTED. EXCEPTION: TREADS SHALL BE PERMITTED TO HAVE A SLOPE NOT STEEPER THAN 1:48. 11B-504.4.1 CONTRASTING STRIPE. INTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND LOWER TREAD MARKED BY A STRIPE PROVIDING CLEAR VISUAL CONTRAST. EXTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND ALL TREADS MARKED BY A STRIPE PROVIDING CLEAR VISUAL CONTRAST. THE STRIPE SHALL BE A MINIMUM OF 2 INCHES (51 MM) WIDE TO A MAXIMUM OF 4 INCHES (102 MM) WIDE PLACED PARALLEL TO, AND NOT MORE THAN 1 INCH (25 MM) FROM, THE NOSE OF THE STEP OR UPPER APPROACH. THE STRIPE SHALL EXTEND THE FULL WIDTH OF THE STEP OR UPPER APPROACH AND SHALL BE OF MATERIAL THAT IS AT LEAST AS SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR. A PAINTED STRIPE SHALL BE ACCEPTABLE. GROOVES SHALL NOT BE USED TO SATISFY THIS REQUIREMENT. 11B-504.5 NOSINGS. THE RADIUS OF CURVATURE AT THE LEADING EDGE OF THE TREAD SHALL BE 1/2 INCH (12.7 MM) MAXIMUM. NOSINGS THAT PROJECT BEYOND RISERS SHALL HAVE THE UNDERSIDE OF THE LEADING EDGE CURVED OR BEVELED. RISERS SHALL BE PERMITTED TO SLOPE UNDER THE TREAD AT AN ANGLE OF 30 DEGREES MAXIMUM FROM VERTICAL. THE PERMITTED PROJECTION OF THE NOSING SHALL EXTEND 1 1/4 INCHES (32 MM) MAXIMUM OVER THE TREAD BELOW. EXCEPTION: IN EXISTING BUILDINGS THERE IS NO REQUIREMENT TO RETROACTIVELY ALTER EXISTING NOSING PROJECTIONS OF 1 1/2 INCHES (38 MM) WHICH WERE CONSTRUCTED IN COMPLIANCE WITH THE BUILDING CODE IN EFFECT AT THE TIME OF ORIGINAL CONSTRUCTION. 11B-504.6 HANDRAILS. STAIRS SHALL HAVE HANDRAILS COMPLYING WITH SECTION 11B-505. 11B-504.7 WET CONDITIONS. STAIR TREADS AND LANDINGS SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO PREVENT THE ACCUMULATION OF WATER. 11B-504.8 FLOOR IDENTIFICATION. FLOOR IDENTIFICATION SIGNS REQUIRED BY CHAPTER 10, SECTION 1023.9 COMPLYING WITH SECTIONS 11B-703.1, 11B-703.2, 11B-703.3 AND 11B-703.5 SHALL BE LOCATED AT THE LANDING OF EACH FLOOR LEVEL, PLACED ADJACENT TO THE DOOR ON THE LATCH SIDE, IN ALL ENCLOSED STAIRWAYS IN BUILDINGS TWO OR MORE STORIES IN HEIGHT TO IDENTIFY THE FLOOR LEVEL. AT THE EXIT DISCHARGE LEVEL, THE SIGN SHALL INCLUDE A RAISED FIVE POINTED STAR LOCATED TO THE LEFT OF THE IDENTIFYING FLOOR LEVEL. THE OUTSIDE DIAMETER OF THE STAR SHALL BE THE SAME AS THE HEIGHT OF THE RAISED CHARACTERS. 1 1/4" MAX 32 1 1/4" MAX 32 30° MAXradius 1/2 max 12.7 FIGURE 11B-504.5 STAIR NOSINGS (c) curved nosing (d) beveled nosing (a) radius of tread edge (typical for all profiles) (b) angled riser 12" (MIN.) 12 " ( M I N . ) NOTES: 1. SIGN TO BE REFLECTORIZED PORCELAIN STEEL. 2. BOTTOM OF SIGN TO BE +60" MINIMUM ABOVE FINISH FLOOR OR GROUND SURFACE OR, +80" ABOVE FINISHED SURFACE WHEN LOCATED IN THE PATH OF TRAVEL. 3. SIGN TO CONFORM TO ALL CURRENT, FEDERAL, STATE, LOCAL CODES AND / OR REGULATIONS. 4. ARROW SHALL POINT IN THE DIRECTION OF THE PATH OF TRAVEL 1/2" RADIUS TYPICAL WHITE ON BLUE BACKGROUND 2" DIA. GALV. POLE 6'-8" MIN. UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT: 17" (MIN.) 24" RECOMMENDED 22 " ( M I N . ) 24 " R E C O M M E N E D E D NOTES: 1. SIGN TO BE REFLECTORIZED PORCELAIN STEEL WITH BEADED TEXT 2.BOTTOM OF SIGN TO BE +60" MINIMUM ABOVE FINISH FLOOR OR GROUND SURFACE OR, +80" ABOVE FINISHED SURFACE WHEN LOCATED IN THE PATH OF TRAVEL. 3. SIGN TO CONFORM TO ALL CURRENT, FEDERAL, STATE, LOCAL CODES AND / OR REGULATIONS. 4. SIGN TO BE PROVIDED AT ALL ENTRY DRIVEWAYS 5. CITY OF XX POLICE DEPARTMENT OR BY CALLING: (XXX) XXX-XXXX. SIGN LETTERING SHALL BE NOT LESS THAN 1" IN HEIGHT (REFER TO NOTE #5) 2" DIA. GALV. POLE 6'-8" MIN. PARKING ONLY MINIMUM FINE $250 VAN ACCESSIBLE NOTES: 1. SIGN TO BE REFLECTORIZED WITH AN AREA OF THE SIGN(S) IS NOT SMALLER THAN 70 SQUARE INCHES 2. SIGN TO BE CENTERED AT THE INTERIOR END OF PARKING SPACE 3.BOTTOM OF SIGN TO BE +60" MINIMUM ABOVE FINISH FLOOR OR GROUND SURFAQCE OR, +80" ABOVE FINISHED SURFACE WHEN LOCATED IN THE PATH OF TRAVEL 4. SIGN TO CONFORM TO ALL CURRENT, FEDERAL, STATE, LOCAL CODES AND / OR REGULATIONS 5. SIGN TO BE PROVIDED AT ALL PARKING SPACES RESERVED FOR PERSONS WITH DISABILITIES WHITE ON BLUE BACKGROUND TYPICAL 1/2" RADIUS TYPICAL VAN ACCESSIBLE SIGN WHERE APPLICABLE 2" DIA. GALV. POLE 6'-8" MIN. 1DIVISION 5 - SITE AND BUILDING ELEMENTS 2 3 DIV. 503 - DROP-OFF AND LOADING ZONES5DIV. 505 - HANDRAILS 4DIV. 504 -STAIRWAYS A0.5e CBC 11B DIV 5 SITE AND BUILDING ELEMENTS AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 8ACCESSIBLE PATH OF TRAVEL 7UNAUTHORIZED VEHICLE WARNING SIGNS 6ACCESSIBLE PARKING STALL SIGNAGE DIVISION 6 PLUMBING ELEMENTS AND FACILITIES 11B-601 GENERAL. 11B-601.1 SCOPE. THE PROVISIONS OF DIVISION 6 SHALL APPLY WHERE REQUIRED BY DIVISION 2 OR WHERE REFERENCED BY A REQUIREMENT IN THIS CHAPTER. 11B-602 DRINKING FOUNTAINS 11B-601.1 11B-602 11B-602.1 11B-602.2 11B-602.3 SCOPE. THE PROVISIONS OF DIVISION 6 SHALL APPLY WHERE REQUIRED BY DIVISION 2 OR WHERE REFERENCED BY A REQUIREMENT IN THIS CHAPTER. DRINKING FOUNTAINS GENERAL. DRINKING FOUNTAINS SHALL COMPLY WITH SECTIONS 11B-307 AND 11B-602. CLEAR FLOOR SPACE. UNITS SHALL HAVE A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH SECTION 11B-305 POSITIONED FOR A FORWARD APPROACH AND CENTERED ON THE UNIT. KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11B-306 SHALL BE PROVIDED. EXCEPTION: A PARALLEL APPROACH COMPLYING WITH SECTION 11B-305 SHALL BE PERMITTED AT UNITS FOR CHILDREN'S USE WHERE THE SPOUT IS 30 INCHES (762 mm) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND AND IS 3 1/2 INCHES (89 mm) MAXIMUM FROM THE FRONT EDGE OF THE UNIT, INCLUDING BUMPERS OPERABLE PARTS. OPERABLE PARTS SHALL COMPLY WITH SECTION 11B-309. THE FLOW OF WATER SHALL BE ACTIVATED BY A MANUALLY OPERATED SYSTEM THAT IS FRONT MOUNTED OR SIDE MOUNTED AND LOCATED WITHIN 6 INCHES (152 mm) OF THE FRONT EDGE OF THE FOUNTAIN OR AN AUTOMATIC ELECTRONICALLY CONTROLLED DEVICE. FIGURE 11B-602.5 DRINKING FOUNTAIN SPOUT LOCATION 11B-602.4 11B-602.5 11B-602.6 11B-602.7 11B-602.8 11B-602.9 SPOUT HEIGHT. SPOUT OUTLETS SHALL BE 36 INCHES (914 mm) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. SPOUT LOCATION. THE SPOUT SHALL BE LOCATED 15 INCHES (381 mm) MINIMUM FROM THE VERTICAL SUPPORT AND 5 INCHES (127 mm) MAXIMUM FROM THE FRONT EDGE OF THE UNIT, INCLUDING BUMPERS. WATER FLOW. THE SPOUT SHALL PROVIDE A FLOW OF WATER 4 INCHES (102 mm) HIGH MINIMUM AND SHALL BE LOCATED 5 INCHES (127 mm) MAXIMUM FROM THE FRONT OF THE UNIT. THE ANGLE OF THE WATER STREAM SHALL BE MEASURED HORIZONTALLY RELATIVE TO THE FRONT FACE OF THE UNIT. WHERE SPOUTS ARE LOCATED LESS THAN 3 INCHES (76 mm) OF THE FRONT OF THE UNIT, THE ANGLE OF THE WATER STREAM SHALL BE 30 DEGREES MAXIMUM. WHERE SPOUTS ARE LOCATED BETWEEN 3 INCHES (76 mm) AND 5 INCHES (127 mm) MAXIMUM FROM THE FRONT OF THE UNIT, THE ANGLE OF THE WATER STREAM SHALL BE 15 DEGREES MAXIMUM. DRINKING FOUNTAINS FOR STANDING PERSONS. SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 INCHES (965 mm) MINIMUM AND 43 INCHES (1092 mm) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. DEPTH. WALL- AND POST-MOUNTED CANTILEVERED DRINKING FOUNTAINS SHALL BE 18 INCHES (457 mm) MINIMUM AND 19 INCHES (483 mm) MAXIMUM IN DEPTH. PEDESTRIAN PROTECTION. ALL DRINKING FOUNTAINS SHALL EITHER BE LOCATED COMPLETELY WITHIN ALCOVES, POSITIONED COMPLETELY BETWEEN WING WALLS, OR OTHERWISE POSITIONED SO AS NOT TO ENCROACH INTO PEDESTRIAN WAYS. THE PROTECTED AREA WITHIN WHICH A DRINKING FOUNTAIN IS LOCATED SHALL BE 32 INCHES (813 mm) WIDE MINIMUM AND 18 INCHES (457 mm) DEEP MINIMUM, AND SHALL COMPLY WITH SECTION 11B-305.7. WHEN USED, WING WALLS OR BARRIERS SHALL PROJECT HORIZONTALLY AT LEAST AS FAR AS THE DRINKING FOUNTAIN AND TO WITHIN 6 INCHES (152 mm) VERTICALLY FROM THE FLOOR OR GROUND SURFACE. 12 75"MI N 38 1 1'- 3 " MI N 11B-603.1 11B-603.2 11B-603.2.1 11B-603.2.2 11B-603.2.3 11B-603 TOILET AND BATHING ROOMS GENERAL. TOILET AND BATHING ROOMS SHALL COMPLY WITH SECTION 11B-603. CLEARANCES. CLEARANCES SHALL COMPLY WITH SECTION 11B-603.2. TURNING SPACE. TURNING SPACE COMPLYING WITH SECTION 11B-304 SHALL BE PROVIDED WITHIN THE ROOM. OVERLAP. REQUIRED CLEAR FLOOR SPACES, CLEARANCE AT FIXTURES, AND TURNING SPACE SHALL BE PERMITTED TO OVERLAP. DOOR SWING. DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS TO ACCESSIBLE WATER CLOSET COMPARTMENTS SHALL BE PERMITTED TO ENCROACH INTO THE TURNING SPACE WITHOUT LIMITATION. OTHER THAN DOORS TO ACCESSIBLE WATER CLOSET COMPARTMENTS, A DOOR, IN ANY POSITION, SHALL BE PERMITTED TO ENCROACH INTO THE TURNING SPACE BY 12 INCHES (305 mm) MAXIMUM. 1. 2. 3. EXCEPTIONS: RESERVED. WHERE THE TOILET ROOM OR BATHING ROOM IS FOR INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYING WITH SECTION 11B-305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE DOOR SWING, DOORS SHALL BE PERMITTED TO SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE. IN RESIDENTIAL DWELLING UNITS COMPLYING WITH SECTION 11B-233.3.1.1, DOORS SHALL BE PERMITTED TO SWING OVER THE TURNING SPACE WITHOUT LIMITATION. 11B-603.3 11B-603.4 11B-603.5 11B-603.6 MIRRORS. MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 40 INCHES (1016 mm) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES (889 mm) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. COAT HOOKS, SHELVES AND MEDICINE CABINETS. COAT HOOKS SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES SPECIFIED IN SECTION 11B-308. SHELVES SHALL BE LOCATED 40 INCHES (1016 mm) MINIMUM AND 48 INCHES (1219 mm) MAXIMUM ABOVE THE FINISH FLOOR. MEDICINE CABINETS SHALL BE LOCATED WITH A USABLE SHELF NO HIGHER THAN 44 INCHES (1118 mm) MAXIMUM ABOVE THE FINISH FLOOR. ACCESSORIES. WHERE TOWEL OR SANITARY NAPKIN DISPENSERS, WASTE RECEPTACLES, OR OTHER ACCESSORIES ARE PROVIDED IN TOILET FACILITIES, AT LEAST ONE OF EACH TYPE SHALL BE LOCATED ON AN ACCESSIBLE ROUTE. ALL OPERABLE PARTS, INCLUDING COIN SLOTS, SHALL BE 40 INCHES (1016 mm) MAXIMUM ABOVE THE FINISH FLOOR. EXCEPTION: BABY CHANGING TABLES ARE NOT REQUIRED TO COMPLY WITH SECTION 11B-603.5. GUEST ROOM TOILET AND BATHING ROOMS. TOILET AND BATHING ROOMS WITHIN GUEST ROOMS THAT ARE NOT REQUIRED TO PROVIDE MOBILITY FEATURES COMPLYING WITH SECTION 11B-806.2 SHALL PROVIDE ALL TOILET AND BATHING FIXTURES IN A LOCATION THAT ALLOWS A PERSON USING A WHEELCHAIR MEASURING 30 INCHES BY 48 INCHES (762 mm BY 1219 mm) TO TOUCH THE WHEELCHAIR TO ANY LAVATORY, URINAL, WATER CLOSET, TUB, SAUNA, SHOWER STALL AND ANY OTHER SIMILAR SANITARY INSTALLATION, IF PROVIDED. GENERAL. WATER CLOSETS AND TOILET COMPARTMENTS SHALL COMPLY WITH SECTIONS 11B-604.2 THROUGH 11B-604.8. EXCEPTION: WATER CLOSETS AND TOILET COMPARTMENTS FOR CHILDREN'S USE SHALL BE PERMITTED TO COMPLY WITH SECTION 11B-604.9. LOCATION. THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE. THE CENTER-LINE OF THE WATER CLOSET SHALL BE 17 INCHES (432 mm) MINIMUM TO 18 INCHES (457 mm) MAXIMUM FROM THE SIDE WALL OR PARTITION, EXCEPT THAT THE WATER CLOSET SHALL BE 17 INCHES (432 mm) MINIMUM AND 19 INCHES (483 mm) MAXIMUM FROM THE SIDE WALL OR PARTITION IN THE AMBULATORY ACCESSIBLE TOILET COMPARTMENT SPECIFIED IN SECTION 11B-604.8.2. WATER CLOSETS SHALL BE ARRANGED FOR A LEFT-HAND OR RIGHT-HAND APPROACH. CLEARANCE. CLEARANCES AROUND WATER CLOSETS AND IN TOILET COMPARTMENTS SHALL COMPLY WITH SECTION 11B-604.3 SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES (1524 mm) MINIMUM MEASURED PERPENDICULAR FROM THE SIDE WALL AND 56 INCHES (1422 mm) MINIMUM MEASURED PERPENDICULAR FROM THE REAR WALL. A MINIMUM 60 INCHES (1524 mm) WIDE AND 48 INCHES (1219 mm) DEEP MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF THE WATER CLOSET. EXCEPTION: IN RESIDENTIAL DWELLING UNITS COMPLYING WITH SECTION 11B-233.3.1.1, MANEUVERING SPACE IN FRONT OF THE WATER CLOSET SHALL BE A MINIMUM 60 INCHES (1524 mm) WIDE AND 36 INCHES (914 MM) DEEP. OVERLAP. THE REQUIRED CLEARANCE AROUND THE WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE WATER CLOSET, ASSOCIATED GRAB BARS, DISPENSERS, SANITARY NAPKIN DISPOSAL UNITS, COAT HOOKS, SHELVES, ACCESSIBLE ROUTES, CLEAR FLOOR SPACE AND CLEARANCES REQUIRED AT OTHER FIXTURES, AND THE TURNING SPACE. NO OTHER FIXTURES OR OBSTRUCTIONS SHALL BE LOCATED WITHIN THE REQUIRED WATER CLOSET CLEARANCE. EXCEPTION: IN RESIDENTIAL DWELLING UNITS, A LAVATORY COMPLYING WITH SECTION 11B-606 SHALL BE PERMITTED ON THE REAR WALL 18 INCHES (457 mm) MINIMUM FROM THE WATER CLOSET CENTERLINE WHERE THE CLEARANCE AT THE WATER CLOSET IS 66 INCHES (1676 mm) MINIMUM MEASURED PERPENDICULAR FROM THE REAR WALL. SEATS. THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH FLOOR SHALL BE 17 INCHES (432 mm) MINIMUM AND 19 INCHES (483 mm) MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. SEATS SHALL BE 2 INCHES (51 mm) HIGH MAXIMUM. 1. 2. 3. EXCEPTIONS: RESERVED. IN RESIDENTIAL DWELLING UNITS, THE HEIGHT OF WATER CLOSETS SHALL BE PERMITTED TO BE 15 INCHES (381 mm) MINIMUM AND 19 INCHES (483 mm) MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF THE SEAT. A 3-INCH (76 mm) HIGH SEAT SHALL BE PERMITTED ONLY IN ALTERATIONS WHERE THE EXISTING FIXTURE IS LESS THAN 15 INCHES (381 mm) HIGH. GRAB BARS. GRAB BARS FOR WATER CLOSETS SHALL COMPLY WITH SECTION 11B-609. GRAB BARS SHALL BE PROVIDED ON THE SIDE WALL CLOSEST TO THE WATER CLOSET AND ON THE REAR WALL. WHERE SEPARATE GRAB BARS ARE REQUIRED ON ADJACENT WALLS AT A COMMON MOUNTING HEIGHT, AN L-SHAPED GRAB BAR MEETING THE DIMENSIONAL REQUIREMENTS OF SECTIONS 11B-604.5.1 AND 11B-604.5.2 SHALL BE PERMITTED. 1. 2. 3. EXCEPTIONS: RESERVED. IN RESIDENTIAL DWELLING UNITS, GRAB BARS SHALL NOT BE REQUIRED TO BE INSTALLED IN TOILET OR BATHROOMS PROVIDED THAT REINFORCEMENT HAS BEEN INSTALLED IN WALLS AND LOCATED SO AS TO PERMIT THE INSTALLATION OF GRAB BARS COMPLYING WITH SECTION 11B-604.5. IN DETENTION OR CORRECTION FACILITIES, GRAB BARS SHALL NOT BE REQUIRED TO BE INSTALLED IN HOUSING OR HOLDING CELLS THAT ARE SPECIALLY DESIGNED WITHOUT PROTRUSIONS FOR PURPOSES OF SUICIDE PREVENTION. SIDE WALL. THE SIDE WALL GRAB BAR SHALL BE 42 INCHES (1067 mm) LONG MINIMUM, LOCATED 12 INCHES (305 mm) MAXIMUM FROM THE REAR WALL AND EXTENDING 54 INCHES (1372 mm) MINIMUM FROM THE REAR WALL WITH THE FRONT END POSITIONED 24 INCHES (610 mm) MINIMUM IN FRONT OF THE WATER CLOSET. REAR WALL. THE REAR WALL GRAB BAR SHALL BE 36 INCHES (914 mm) LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER CLOSET 12 INCHES (305 mm MINIMUM ON ONE SIDE AND 24 INCHES (610 mm) MINIMUM ON THE OTHER SIDE. 1. 2. EXCEPTIONS: THE REAR GRAB BAR SHALL BE PERMITTED TO BE 24 INCHES (610 mm) LONG MINIMUM, CENTERED ON THE WATER CLOSET, WHERE WALL SPACE DOES NOT PERMIT A LENGTH OF 36 INCHES (914 mm) MINIMUM DUE TO THE LOCATION OF A RECESSED FIXTURE ADJACENT TO THE WATER CLOSET. WHERE AN ADMINISTRATIVE AUTHORITY REQUIRES FLUSH CONTROLS FOR FLUSH VALVES TO BE LOCATED IN A POSITION THAT CONFLICTS WITH THE LOCATION OF THE REAR GRAB BAR, THEN THE REAR GRAB BAR SHALL BE PERMITTED TO BE SPLIT OR SHIFTED TO THE OPEN SIDE OF THE TOILET AREA. FLUSH CONTROLS. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH SECTION 11B-309 EXCEPT THEY SHALL BE LOCATED 44 INCHES (1118 mm) MAXIMUM ABOVE THE FLOOR. FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET EXCEPT IN AMBULATORY ACCESSIBLE COMPARTMENTS COMPLYING WITH SECTION 11B-604.8.2. DISPENSERS AND DISPOSAL UNITS. TOILET PAPER DISPENSERS AND SANITARY NAPKIN DISPOSAL UNITS SHALL COMPLY WITH SECTION 11B-604.7. COMBINATION ACCESSORY UNITS ARE NOT PERMITTED TO ENCROACH INTO THE SPACE REQUIRED BY SECTION 11B-609.3. TOILET COMPARTMENTS. WHEELCHAIR ACCESSIBLE TOILET COMPARTMENTS SHALL MEET THE REQUIREMENTS OF SECTIONS 11B-604.8.1 AND 11B-604.8.3. COMPARTMENTS CONTAINING MORE THAN ONE DISPOSAL UNITS. SANITARY NAPKIN DISPOSAL UNITS, IF PROVIDED, SHALL COMPLY WITH SECTION 11B-309.4 AND SHALL BE WALL MOUNTED AND LOCATED ON THE SIDEWALL BETWEEN THE REAR WALL OF THE TOILET AND THE TOILET PAPER DISPENSER, ADJACENT TO THE TOILET PAPER DISPENSER. THE DISPOSAL UNIT SHALL BE LOCATED BELOW THE GRAB BAR WITH THE OPENING OF THE DISPOSAL UNIT 19 INCHES MINIMUM (483 mm) ABOVE THE FINISH FLOOR. DISPENSERS. TOILET PAPER DISPENSERS SHALL COMPLY WITH SECTION 11B-309.4 AND SHALL BE 7 INCHES (178 mm) MINIMUM AND 9 INCHES (229 mm) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE DIS-PENSER. THE OUTLET OF THE DISPENSER SHALL BE BELOW THE GRAB BAR, 19 INCHES (483 mm) MINIMUM ABOVE THE FINISH FLOOR AND SHALL NOT BE LOCATED BEHIND GRAB BARS. DISPENSERS SHALL NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT DOES NOT ALLOW CONTINUOUS PAPER FLOW. 11B-604.1 11B-604.2 11B-604.3 11B-604.3.1 11B-604.3.2 11B-604.4 11B-604.5 11B-604.5.1 11B-604.6 11B-604.7 11B-604.7.1 11B-604.7.2 11B-604.8 11B-604.5.2 PLUMBING FIXTURE SHALL COMPLY WITH SECTION 11B-603. AMBULATORY ACCESSIBLE COMPARTMENTS SHALL COMPLY WITH SECTIONS 11B-604.8.2 AND 11B-604.8.3. WHEELCHAIR ACCESSIBLE COMPARTMENTS. WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL COMPLY WITH SECTION 11B-604.8.1. 11B-604.8.1 11B-604.8.1.1 11B-604.8.1.1.1 11B-604.8.1.1.2 11B-604.8.1.1.3 11B-604.8.1.2 MANEUVERING SPACE WITH IN-SWINGING DOOR. IN A WHEELCHAIR ACCESSIBLE COMPARTMENT WITH AN INSWINGING DOOR, A MINIMUM 60 INCHES (1524 mm) WIDE BY 36 INCHES (914 mm) DEEP MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF THE CLEARANCE REQUIRED IN SECTION 11B-604.8.1.1. SEE FIGURES 11B-604.8.1.1.2 (B) AND 11B-604.8.1.1.3 (B). MANEUVERING SPACE WITH SIDE-OPENING DOOR. IN A WHEELCHAIR ACCESSIBLE COMPARTMENT WITH A DOOR LOCATED IN THE SIDE WALL OR PARTITION, EITHER IN-SWINGING OR OUT- SWINGING, A MINIMUM 60 INCHES (1524 mm) WIDE AND 60 INCHES (1524 mm) DEEP MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF THE WATER CLOSET. SEE FIGURE 11B-604.8.1.1.2. MANEUVERING SPACE WITH END-OPENING DOOR. IN A WHEELCHAIR ACCESSIBLE COMPARTMENT WITH A DOOR LOCATED IN THE FRONT WALL OR PARTITION (FACING THE WATER CLOSET), EITHER IN-SWINGING OR OUT-SWINGING, A MINIMUM 60 INCHES (1524 mm) WIDE AND 48 INCHES (1219 mm) DEEP MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF THE WATER CLOSET. SEE FIGURE 11B-604.8.1.1.3. DOORS. TOILET COMPARTMENT DOORS, INCLUDING DOOR HARDWARE, SHALL COMPLY WITH SECTION 11B-404 EXCEPT THAT IF THE APPROACH IS FROM THE PUSH SIDE OF THE COMPARTMENT DOOR, CLEARANCE BETWEEN THE DOOR SIDE OF THE COMPARTMENT AND ANY OBSTRUCTION SHALL BE 48 INCHES (1219 mm) MINIMUM MEASURED PERPENDICULAR TO THE COMPARTMENT DOOR IN ITS CLOSED POSITION. DOORS SHALL BE LOCATED IN THE FRONT PARTITION OR IN THE SIDE WALL OR PARTITION FARTHEST FROM THE WATER CLOSET. WHERE LOCATED IN THE FRONT PARTITION, THE DOOR OPENING SHALL BE 4 INCHES (102 mm) MAXIMUM FROM THE SIDE WALL OR PARTITION FARTHEST FROM THE WATER CLOSET. WHERE LOCATED IN THE SIDE WALL OR PARTITION, THE DOOR OPENING SHALL BE 4 INCHES (102 mm) MAXIMUM FROM THE FRONT PARTITION. THE DOOR SHALL BE SELF-CLOSING. A DOOR PULL COMPLYING WITH SECTION 11B-404.2.7 SHALL BE PLACED ON BOTH SIDES OF THE DOOR NEAR THE LATCH. DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS MAY SWING INTO THAT PORTION OF MANEUVERING SPACE WHICH DOES NOT OVERLAP THE CLEARANCE REQUIRED AT A WATER CLOSET. EXCEPTION: WHEN LOCATED AT THE SIDE OF A TOILET COMPARTMENT, THE TOILET COMPARTMENT DOOR OPENING SHALL PROVIDE A CLEAR WIDTH OF 34 INCHES (864 mm) MINIMUM. APPROACH. COMPARTMENTS SHALL BE ARRANGED FOR LEFT-HAND OR RIGHT-HAND APPROACH TO THE WATER CLOSET. TOE CLEARANCE. AT LEAST ONE SIDE PARTITION SHALL PROVIDE A TOE CLEARANCE OF 9 INCHES (229 mm) MINIMUM ABOVE THE FINISH FLOOR AND 6 INCHES (152 mm) DEEP MINIMUM BEYOND THE COMPARTMENT- SIDE FACE OF THE PARTITION, EXCLUSIVE OF PARTITION SUPPORT MEMBERS. PARTITION COMPONENTS AT TOE CLEARANCES SHALL BE SMOOTH WITHOUT SHARP EDGES OR ABRASIVE SURFACES. COMPARTMENTS FOR CHILDREN ’S USE SHALL PROVIDE A TOE CLEARANCE OF 12 INCHES (305 mm) MINIMUM ABOVE THE FINISH FLOOR. EXCEPTION: TOE CLEARANCE AT THE SIDE PARTITION IS NOT REQUIRED IN A COMPARTMENT GREATER THAN 66 INCHES (1676 mm) WIDE. 11B-604.8.1.3 11B-604.8.1.4 11B-604.8.1.5 11B-604.8.2 11B-604.8.2.1 11B-604.8.2.2 11B-604.8.2.3 11B-604.8.3 GRAB BARS. GRAB BARS SHALL COMPLY WITH SECTION 11B-609. A SIDE-WALL GRAB BAR COMPLYING WITH SECTION 11B-604.5.1 SHALL BE PROVIDED AND SHALL BE LOCATED ON THE WALL CLOSEST TO THE WATER CLOSET. IN ADDITION, A REAR-WALL GRAB BAR COMPLYING WITH SECTION 11B-604.5.2 SHALL BE PROVIDED. WHERE SEPARATE GRAB BARS ARE REQUIRED ON ADJACENT WALLS AT A COMMON MOUNTING HEIGHT, AN L-SHAPED GRAB BAR MEETING THE DIMENSIONAL REQUIREMENTS OF SECTIONS 11B-604.5.1 AND 11B-604.5.2 SHALL BE PERMITTED. AMBULATORY ACCESSIBLE COMPARTMENTS. AMBULATORY ACCESSIBLE COMPARTMENTS SHALL COMPLY WITH SECTION 11B-604.8.2. SIZE. AMBULATORY ACCESSIBLE COMPARTMENTS SHALL HAVE A DEPTH OF 60 INCHES (1524 mm) MINIMUM AND A WIDTH OF 35 INCHES (889 mm) MINIMUM AND 37 INCHES (940 mm) MAXIMUM. DOORS. TOILET COMPARTMENT DOORS, INCLUDING DOOR HARDWARE, SHALL COMPLY WITH SECTION 11B-404, EXCEPT THAT IF THE APPROACH IS TO THE LATCH SIDE OF THE COMPARTMENT DOOR, CLEARANCE BETWEEN THE DOOR SIDE OF THE COMPARTMENT AND ANY OBSTRUCTION SHALL BE 44 INCHES (1118 mm) MINIMUM. THE DOOR SHALL BE SELF CLOSING. A DOOR PULL COMPLYING WITH SECTION 11B-404.2.7 SHALL BE PLACED ON BOTH SIDES OF THE DOOR NEAR THE LATCH. TOILET COMPARTMENT DOORS SHALL NOT SWING INTO THE MINIMUM REQUIRED COMPARTMENT AREA. GRAB BARS. GRAB BARS SHALL COMPLY WITH SECTION 11B-609. A SIDE-WALL GRAB BAR COMPLYING WITH SECTION 11B-604.5.1 SHALL BE PROVIDED ON BOTH SIDES OF THE COMPARTMENT. COAT HOOKS AND SHELVES. COAT HOOKS SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES SPECIFIED IN SECTION 11B-308. SHELVES SHALL BE LOCATED 40 INCHES (1016 mm) MINIMUM AND 48 INCHES (1219 mm) MAXIMUM ABOVE THE FINISH FLOOR. 11B-604 WATER CLOSETS AND TOILET COMPARTMENTS 17" - 19" 432 - 483 5'- 0 " M I N 15 2 4 4'-0" MIN 1219 clearance door permitted to swing over hatched portion of maneuvering space 5'- 6 " M I N 16 7 6 5'-0" MIN 1524 4'-6" MIN 1372 3'-6" MIN 1067 1'-0" MAX 305 2'-0" MIN 610 (from bowl face) 1'-0" MIN 305 2'-0" MIN 610 3'-0" MIN 915 17" - 18" 432 - 457 transfer side 1' - 7 " 48 3 (from bowl face) 7" -9" 180 - 230 1422 4'-8" MIN 1499 4'-11" MIN 864 34" min clr 1524 5'-0" MIN (from bowl face) at floor mounted water closet at wall mounted water closet side door maneuvering space at side door floor mount clearance wall mount door permitted to swing over hatched portion of maneuvering space 15 2 4 5'- 0 " M I N 1524 5'-0" MIN (from bowl face) 15 2 4 5' - 0 " M I N 1422 4'-8" MIN 1499 4'-11" MIN at floor mounted water closet at wall mounted water closet at in-swing door side door maneuvering space at floor mounted water closet at wall mounted water closet at floor mounted water closet at wall mounted water closet at in-swing door end door maneuvering spaceend door maneuvering space 1422 4'-8" MIN 1499 4'-11" MIN floor mount clearance wall mount 15 2 4 5' - 0 " M I N 1524 4'-0" MIN (from bowl face) 1422 4'-8" MIN 1499 4'-11" MIN 15 2 4 5' - 0 " M I N 914 3'-0" MIN door permitted to swing over hatched portion of maneuvering space 864 34" min clr 10 2 4" M A X alternate door location at side door 1524 5'-0" MIN 88 9 - 9 4 0 2' - 1 1 " - 3 ' 1 " 1118 3'-8" MIN 152 6" MIN 15 2 6" M I N 152 6" MIN 152 6" MIN partition 1'-6" MIN 457 4'-8" MIN 1422 102 4" MAX 1524 4'-0" MIN (from bowl face) 914 3'-0" MIN (b) elevation children FIGURE 11B-604.8.1.4 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT TOE CLEARANCE (a) elevation adult (c) plan 23 0 9" M I N 30 5 1' - 0 " M I N FIGURE 11B-604.8.2 AMBULATORY ACCESSIBLE TOILET COMPARTMENT FIGURE 11B-604.8.1.2 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT DOORS FIGURE 11B-604.8.1.1.2 MANEUVERING SPACE WITH SIDE-OPENING DOOR (a) out-swinging door (b) in-swinging door FIGURE 11B-604.8.1.1.2 MANEUVERING SPACE WITH SIDE-OPENING DOOR (a) out-swinging door (b) in-swinging door FIGURE 11B-604.7 DISPENSER OUTLET LOCATION FIGURE 11B-604.5.2 REAR WALL GRAB BAR AT WATER CLOSETS FIGURE 11B-604.5.1 SIDE WALL GRAB BAR AT WATER CLOSETS FIGURE 11B-604.3.2 (EXCEPTION) OVERLAP OF WATER CLOSET CLEARANCE IN RESIDENTIAL WELLING UNITS FIGURE 11B-604.3.1 SIZE OF CLEARANCE AT WATER CLOSETS FIGURE 11B-604.2 WATER CLOSET LOCATION (b) ambulatory accessible water closets (a) wheelchair accessible water closets SIZE. WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL BE 60 INCHES (1524 mm) WIDE MINIMUM MEASURED PERPENDICULAR TO THE SIDE WALL, AND 56 INCHES (1422 mm) DEEP MINIMUM FOR WALL HUNG WATER CLOSETS AND 59 INCHES (1499 mm) DEEP MINIMUM FOR FLOOR MOUNTED WATER CLOSETS MEASURED PERPENDICULAR TO THE REAR WALL. WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL ADDITIONALLY PROVIDE MANEUVERING SPACE COMPLYING WITH SECTION 11B-604.8.1.1.1, 11B-604.8.1.1.2, OR 11B-604.8.1.1.3, AS APPLICABLE. WHEELCHAIR ACCESSIBLE COMPARTMENTS FOR CHILDREN'S USE SHALL BE 60 INCHES (1524 mm) WIDE MINIMUM MEASURED PERPENDICULAR TO THE SIDE WALL, AND 59 INCHES (1499 mm) DEEP MINIMUM FOR WALL HUNG AND FLOOR MOUNTED WATER CLOSETS MEASURED INCHES (1499 mm) DEEP MINIMUM FOR WALL HUNG AND FLOOR MOUNTED WATER CLOSETS MEASURED PERPENDICULAR TO THE REAR WALL. GENERAL. URINALS SHALL COMPLY WITH SECTION 11B-605. HEIGHT AND DEPTH. URINALS SHALL BE THE STALL-TYPE OR THE WALL-HUNG TYPE WITH THE RIM 17 INCHES (432 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. URINALS SHALL BE 13 1/2 INCHES (343 mm) DEEP MINIMUM MEASURED FROM THE OUTER FACE OF THE URINAL RIM TO THE BACK OF THE FIXTURE CLEAR FLOOR SPACE. A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH SECTION 11B-305 POSITIONED FOR FORWARD APPROACH SHALL BE PROVIDED. FLUSH CONTROLS. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH SECTION 11B-309 EXCEPT THAT THE FLUSH CONTROL SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 44 INCHES (1118 mm) ABOVE THE FINISH FLOOR. 11B-605.1 11B-605.2 11B-605.3 11B-605.4 11B-605 URINALS 343 1'-1 1/2" MIN 43 2 1'5 " MA X 343 1'-1 1/2" MIN (a) wall hung type (b) stall type FIGURE 11B-605.2 HEIGHT AND DEPTH OF URINALS 11B-606 LAVATORIES AND SINKS 11B-606.1 11B-606.2 GENERAL. LAVATORIES AND SINKS SHALL COMPLY WITH SECTION 11B-606. CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE COMPLYING WITH SECTION 11B-305, POSITIONED FOR A FOR WARD APPROACH, AND KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11B-306 SHALL BE PROVIDED. 11B-606.3 11B-606.4 11B-606.5 11B-606.6 11B-606.7 1. 2. 3. 4. 5. 6. 7. EXCEPTIONS: A PARALLEL APPROACH COMPLYING WITH SECTION 11B-305 SHALL BE PERMITTED TO A KITCHEN SINK IN A SPACE WHERE A COOK TOP OR CONVENTIONAL RANGE IS NOT PROVIDED AND TO WET BARS. RESERVED. IN RESIDENTIAL DWELLING UNITS, CABINETRY SHALL BE PERMITTED UNDER LAVATORIES AND KITCHEN SINKS PROVIDED THAT ALL OF THE FOLLOWING CONDITIONS ARE MET: (a) THE CABINETRY CAN BE REMOVED WITHOUT REMOVAL OR REPLACEMENT OF THE FIXTURE; (b) THE FINISH FLOOR EXTENDS UNDER THE CABINETRY; AND (c) THE WALLS BEHIND AND SURROUNDING THE CABINETRY ARE FINISHED. A KNEE CLEARANCE OF 24 INCHES (610 mm) MINIMUM ABOVE THE FINISH FLOOR OR GROUND SHALL BE PERMITTED AT LAVATORIES AND SINKS USED PRIMARILY BY CHILDREN 6 THROUGH 12 YEARS WHERE THE RIM OR COUNTER SURFACE IS 31 INCHES (787 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. A PARALLEL APPROACH COMPLYING WITH SECTION 11B-305 SHALL BE PERMITTED TO LAVATORIES AND SINKS USED PRIMARILY BY CHILDREN 5 YEARS AND YOUNGER. THE DIP OF THE OVERFLOW SHALL NOT BE CONSIDERED IN DETERMINING KNEE AND TOE CLEARANCES. NO MORE THAN ONE BOWL OF A MULTIBOWL SINK SHALL BE REQUIRED TO PROVIDE KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11B-306. HEIGHT. LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES (864 mm) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. 1. 2. EXCEPTIONS: RESERVED. IN RESIDENTIAL DWELLING UNIT KITCHENS, SINKS THAT ARE ADJUSTABLE TO VARIABLE HEIGHTS, 29 INCHES (737 mm) MINIMUM AND 36 INCHES (914 mm) MAXIMUM, SHALL BE PERMITTED WHERE ROUGH-IN PLUMBING PERMITS CONNECTIONS OF SUPPLY AND DRAIN PIPES FOR SINKS MOUNTED AT THE HEIGHT OF 29 INCHES (737 mm). FAUCETS. CONTROLS FOR FAUCETS SHALL COMPLY WITH SECTION 11B-309. HAND-OPERATED METERING FAUCETS SHALL REMAIN OPEN FOR 10 SECONDS MINIMUM. EXPOSED PIPES AND SURFACES. WATER SUPPLY AND DRAIN PIPES UNDER LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES AND SINKS. ADJACENT SIDE WALL OR PARTITION. LAVATORIES, WHEN LOCATED ADJACENT TO A SIDE WALL OR PARTITION, SHALL BE A MINIMUM OF 18 INCHES (457 mm) TO THE CENTERLINE OF THE FIXTURE. SINK DEPTH. WHERE A FORWARD APPROACH IS REQUIRED AT A SINK, KNEE AND TOE CLEARANCE SHALL BE PROVIDED IN COMPLIANCE WITH SECTION 11B-306. 11B-609.1 11B-609 GRAB BARS 11B-609.2 11B-609.2.1 11B-609.2.2 GENERAL. GRAB BARS IN TOILET FACILITIES AND BATHING FACILITIES SHALL COMPLY WITH SECTION 11B-609. CROSS SECTION. GRAB BARS SHALL HAVE A CROSS SECTION COMPLYING WITH SECTION 11B-609.2.1 OR 11B-609.2.2. CIRCULAR CROSS SECTION. GRAB BARS WITH CIRCULAR CROSS SECTIONS SHALL HAVE AN OUTSIDE DIAMETER OF 1 1/4 INCHES (32 mm) MINIMUM AND 2 INCHES (51 mm) MAXIMUM. NON-CIRCULAR CROSS SECTION. GRAB BARS WITH NON-CIRCULAR CROSS SECTIONS SHALL HAVE A CROSS-SECTION DIMENSION OF 2 INCHES (51 mm) MAXIMUM AND A PERIMETER DIMENSION OF 4 INCHES (102 mm) MINIMUM AND 4.8 INCHES (122 mm) MAXIMUM. 11B-609.3 1. 2. EXCEPTIONS: THE SPACE BETWEEN THE GRAB BARS AND SHOWER CONTROLS, SHOWER FITTINGS, AND OTHER GRAB BARS ABOVE SHALL BE PERMITTED TO BE 1 1/2 INCHES (38 mm) MINIMUM. FOR L-SHAPED OR U-SHAPED GRAB BARS COMPLYING WITH SECTION 11B-609.9 THE SPACE BETWEEN THE WALLS AND THE GRAB BAR SHALL BE 1 1/2 INCHES (38 mm) MINIMUM FOR A DISTANCE OF 6 INCHES ON EITHER SIDE OF THE INSIDE CORNER BETWEEN TWO ADJACENT WALL SURFACES. SPACING. THE SPACE BETWEEN THE WALL AND THE GRAB BAR SHALL BE 1 1/2 INCHES (38 mm). THE SPACE BETWEEN THE GRAB BAR AND PROJECTING OBJECTS BELOW AND AT THE ENDS SHALL BE 1 1/2 INCHES (38 mm) MINIMUM. THE SPACE BETWEEN THE GRAB BAR AND PROJECTING OBJECTS ABOVE SHALL BE 12 INCHES (305 mm) MINIMUM. POSITION OF GRAB BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33 INCHES (838 mm) MINIMUM AND 36 INCHES (914 mm) MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE, EXCEPT THAT AT WATER CLOSETS FOR CHILDREN'S USE COMPLYING WITH SECTION 11B-604.9, GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION 18 INCHES (457 mm) MINIMUM AND 27 INCHES (686 mm MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE. THE HEIGHT OF THE LOWER GRAB BAR ON THE BACK WALL OF A BATHTUB SHALL COMPLY WITH SECTION 11B-607.4.1.1 OR 11B-607.4.2.1. 11B-609.4 11B-609.5 11B-609.6 11B-609.7 11B-609.8 11B-609.9 SURFACE HAZARDS. GRAB BARS AND ANY WALL OR OTHER SURFACES ADJACENT TO GRAB BARS SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS AND SHALL HAVE ROUNDED EDGES. FITTINGS. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. INSTALLATION. GRAB BARS SHALL BE INSTALLED IN ANY MANNER THAT PROVIDES A GRIPPING SURFACE AT THE SPECIFIED LOCATIONS AND THAT DOES NOT OBSTRUCT THE REQUIRED CLEAR FLOOR SPACE. STRUCTURAL STRENGTH. ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS (1112 N) IS APPLIED AT ANY POINT ON THE GRAB BAR, FASTENER, MOUNTING DEVICE, OR SUPPORTING STRUCTURE. ALTERNATE CONFIGURATION. L-SHAPED OR U-SHAPED GRAB BARS SHALL BE PERMITTED. 30 5 1'- 0 " M I N 38 1 1 / 2 " MI N (a) projecting objects (b) recessed objects FIGURE 11B-609.3 SPACING OF GRAB BARS 38 1 1/2"38 1 1/2" 4" - 4.8" perimeter 102 - 122 FIGURE 11B-609.2.2 GRAB BAR NON-CIRCULAR CROSS SECTION 51 2" MAX 51 2" MAX (a)(b) EXIT & RESTROOM SIGNAGE 6" 48 " M I N . T O L O W E S T LI N E O F B R A I L L E 60 " M A X . EXIT ROUTE EXIT EXIT 12 " 3" EQ.EQ. AL I G N W I T H T O P O F A D J . F R A M E 12 " O R GR E A T E R 18"MIN. CLEAR ℄ EQ.EQ. 45 ° 18 " M I N . CL E A R 18"MIN. CLEAR MEN WOMEN ALL GENDER 6" 3 WOMEN'S ACCESSIBLE TOILET SIGNAGE 2 MEN'S ACCESSIBLE TOILET SIGNAGE 1 UNISEX / ALL GENDER ACCESSIBLE TOILET SIGNAGE 12 " 6" 12 " 6" 12 " ℄ EQ. 60 " M A X . B A S E L I N E O F H I G H E S T LE V E L O F R A I S E D C H A R A C T E R S ℄ 48 " M I N . T O L O W E S T LI N E O F B R A I L L E EQ EQ 60 " M A X . 58 " - 6 0 " ℄ EQ. ℄ ALL GENDERRESTROOMALL GENDERRESTROOM 18"MIN. CLEAR B SIGNAGE LOCATION AT TOILET ROOM DOOR A EXIT, EXIT ROUTE, EXIT STAIRS & ROOM SIGNAGE C TYPICAL LOCATION OF TACTILE SIGNS AT DOORS 1 DIVISION 6 - PLUMBING ELEMENTS & FACILITIES 2DIV. 602 - DRINKING FOUNTAINS 3DIV. 603 - TOILET AND BATHING ROOMS 4DIV. 604 - WATER CLOSETS AND TOILET COMPARTMENTS5DIV. 605 - URINALS6DIV. 606 - LAVATORIES AND SINKS 7DIV. 609 - GRAB BARS A0.5f CBC 11B DIV 6 PLUMBING ELEMENTS & FACILITIES AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 EXIT & RESTROOM SIGNAGE 7 11B-701.1 SCOPE. THE PROVISIONS OF DIVISION 7 SHALL APPLY WHERE REQUIRED BY DIVISION 2 OR WHERE REFERENCED BY A REQUIREMENT IN THIS CHAPTER 11B-701 GENERAL DIVISION 7: COMMUNICATION ELEMENTS AND FEATURES 11 B-702.1 GENERAL. FIRE ALARM SYSTEMS SHALL HAVE PERMANENTLY INSTALLED AUDIBLE AND VISIBLE ALARMS COMPLYING WITH NFPA 72 AND CHAPTER 9, SECTIONS 907.5.2.1 AND 907.5.2.3. 11B-702 FIRE ALARM SYSTEMS EXCEPTION: RESERVED. 11B-703.7.2.3 VOLUME CONTROL TELEPHONES. TELEPHONES WITH A VOLUME CONTROL SHALL BE IDENTIFIED BY A PICTOGRAM OF A TELEPHONE HANDSET WITH RADIATING SOUND WAVES ON A SQUARE FIELD SUCH AS SHOWN IN FIGURE 11 B703.7.2.3. 11B-703.7.2.4 ASSISTIVE LISTENING SYSTEMS. ASSISTIVE LISTENING SYSTEMS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS COMPLYING WITH FIGURE 11B-703.7.2.4. 11B-703.7.2.5 CLEANER AIR SYMBOL. ROOMS, FACILITIES AND PATHS OF TRAVEL THAT ARE ACCESSIBLE TO AND USABLE BY PEOPLE WHO ARE ADVERSELY IMPACTED BY AIRBORNE CHEMICALS OR PARTICULATE( S) AND/OR THE USE OF ELECTRICAL FIXTURES AND/OR DEVICES SHALL BE IDENTIFIED BY THE CLEANER AIR SYMBOL COMPLYING WITH FIGURE 11B-703.7.2.5. THIS SYMBOL IS TO BE USED STRICTLY FOR PUBLICLY FUNDED FACILITIES OR ANY FACILITIES LEASED OR RENTED BY STATE OF CALIFORNIA,NOT CONCESSIONAIRES. THE SYMBOL, WHICH SHALL INCLUDE THE TEXT "CLEANER AIR" AS SHOWN, SHALL BE DISPLAYED EITHER AS A NEGATIVE OR POSITIVE IMAGE WITHIN A SQUARE THAT IS A MINIMUM OF 6 INCHES ( 152 MM) ON EACH SIDE. THE SYMBOL MAY BE SHOWN IN BLACK AND WHITE OR IN COLOR. WHEN COLOR IS USED, IT SHALL BE FEDERAL BLUE (COLOR NO. 15090 FEDERAL STANDARD 595B) ON WHITE, OR WHITE ON FEDERAL BLUE. THERE SHALL BE AT LEAST A 70-PERCENT COLOR CONTRAST BETWEEN THE BACKGROUND OF THE SIGN FROM THE SURFACE THAT IT IS MOUNTED ON. 11B-703.7.2.6 TOILET AND BATHING FACILITIES GEOMETRIC SYMBOLS. DOORWAYS LEADING TO TOILET ROOMS AND BATHING ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC SYMBOL COMPLYING WITH SECTION 11 B-703. 7.2.6. THE SYMBOL SHALL BE MOUNTED AT 58 INCHES (1473 MM) MINIMUM AND 60 INCHES ( 1524 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE MEASURED FROM THE CENTERLINE OF THE SYMBOL. WHERE A DOOR IS PROVIDED THE SYMBOL SHALL BE MOUNTED WITHIN 1 INCH (25 MM) OF THE VERTICAL CENTERLINE OF THE DOOR. EXCEPTION:GEOMETRIC SYMBOLS SHALL NOT BE REQUIRED AT INMATE TOILET ROOMS AND BATHING ROOMS IN DETENTION AND CORRECTIONAL FACILITIES WHERE ONLY ONE GENDER IS HOUSED. 11B-703.7.2.6.1 MEN'S TOILET AND BATHING FACILITIES. MEN'S TOILET AND BATHING FACILITIES SHALL BE IDENTIFIED BY AN EQUILATERAL TRIANGLE, 1/4 INCH (6.4 MM) THICK WITH EDGES 12 INCHES (305 MM) LONG AND A VERTEX POINTING UPWARD. THE TRIANGLE SYMBOL SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND.EXCEPTION:WITHIN SECURE PERIMETER OF DETENTION AND CORRECTIONAL FACILITIES, GEOMETRIC SYMBOLS SHALL NOT BE REQUIRED TO BE 114 INCH (6.4 MM) THICK. 11B-703.7.2.6.2 WOMEN'S TOILET AND BATHING FACILITIES. WOMEN'S TOILET AND BATHING FACILITIES SHALL BE IDENTIFIED BY A CIRCLE, 114 INCH (6.4 MM) THICK AND 12 INCHES ( 305 MM) IN DIAMETER. THE CIRCLE SYMBOL SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. EXCEPTION: WITHIN SECURE PERIMETER OF DETENTION AND CORRECTIONAL FACILITIES, GEOMETRIC SYMBOLS SHALL NOT BE REQUIRED TO BE 114 INCH (6.4 MM) THICK. 11B-703.7.2.6.3 UNISEX TOILET AND BATHING FACILITIES. UNISEX TOILET AND BATHING FACILITIES SHALL BE IDENTIFIED BY A CIRCLE, 114 INCH (6.4 MM) THICK AND 12 INCHES ( 305 MM) IN DIAMETER WITH A LF4 INCH (6.4 MM) THICK TRIANGLE WITH A VERTEX POINTING UPWARD SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12-INCH (305 MM) DIAMETER. THE TRIANGLE SYMBOL SHALL CONTRAST WITH THE CIRCLE SYMBOL, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. THE CIRCLE SYMBOL SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. EXCEPTION:WITHIN SECURE PERIMETER OF DETENTION AND CORRECTIONAL FACILITIES, GEOMETRIC SYMBOLS SHALL NOT BE REQUIRED TO BE 1/4 INCH (6.4 MM) THICK. 11B-703.7.2.6.4 EDGES AND CORNERS. EDGES OF SIGNS SHALL BE ROUNDED, CHAMFERED OR EASED. CORNERS OF SIGNS SHALL HAVE A MINIMUM RADIUS OF 118 INCH ( 3.2 MM). 11B-703.7.2.7 PEDESTRIAN TRAFFIC-CONTROL BUTTONS. POLE-SUPPORTED PEDESTRIAN TRAFFIC-CONTROL BUTTONS SHALL BE IDENTIFIED WITH COLOR CODING CONSISTING OF A TEXTURED HORIZONTAL YELLOW BAND 2 INCHES (51 MM) IN WIDTH ENCIRCLING THE POLE, AND A L-INCH-WIDE (25 MM) DARK BORDER BAND ABOVE AND BELOW THIS YELLOW BAND. COLOR CODING SHALL BE PLACED IMMEDIATELY ABOVE THE CONTROL BUTTON. CONTROL BUTTONS SHALL BE LOCATED NO HIGHER THAN 48 INCHES (1219 MM) ABOVE THE GROUND SURFACE ADJACENT TO THE POLE. 11B-703.7.2.2 INTERNATIONAL SYMBOL OF TTY. THE INTERNATIONAL SYMBOL OF TTY SHALL COMPLY WITH THE FIGURE 11B-703.7.2.2. EXCEPTION:THE APPROPRIATE ENFORCEMENT AGENCY MAY APPROVE OTHER COLORS TO COMPLEMENT DECOR OR UNIQUE DESIGN. THE SYMBOL CONTRAST SHALL BE LIGHT ON DARK OR DARK ON LIGHT. 11B-703.7.2.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL COMPLY WITH FIGURE 11B-703.7.2.1. THE SYMBOL SHALL CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE COLOR NO. 15090 IN FEDERAL STANDARD 5958. 11B-703.7.2 SYMBOLS 11B-703.7.1 FINISH AND CONTRAST. SYMBOLS OF ACCESSIBILITY AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. SYMBOLS OF ACCESSIBILITY SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER A LIGHT SYMBOL ON A DARK BACKGROUND OR A DARK SYMBOL ON A LIGHT BACKGROUND 11B-703.7 SYMBOLS OF ACCESSIBILITY. SYMBOLS OF ACCESSIBILITY SHALL COMPLY WITH SECTION 11 B-703.7 11B-703.6.3 TEXT DESCRIPTORS. PICTOGRAMS SHALL HAVE TEXT DESCRIPTORS LOCATED DIRECTLY BELOW THE PICTOGRAM FIELD. TEXT DESCRIPTORS SHALL COMPLY WITH SECTIONS 11B-703.2, 11B-703.3 AND 11B-703.4. 11B-703.6.2 FINISH AND CONTRAST. PICTOGRAMS AND THEIR FIELD SHALL HAVE A NON-GLARE FINISH. PICTOGRAMS SHALL CONTRAST WITH THEIR FIELD WITH EITHER A LIGHT PICTOGRAM ON A DARK FIELD OR A DARK PICTOGRAM ON A LIGHT FIELD. 11B-703.6.1 11B-703.6 11B-703.5.10 11B-703.5.9 11B-703.5.8 11B-703.5.7 11B-703.5.6 EXCEPTION:S: 3. 2. 1. HEIGHT FROM FINISH FLOOR OR GROUND. VISUAL CHARACTERS SHALL BE 40 INCHES (1016 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND VISUAL CHARACTERS INDICATING ELEVATOR CAR CONTROLS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B703.5.6. FLOOR-LEVEL EXIT SIGNS COMPLYING WITH CHAPTER 10, SECTION 1011.7 SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-703.5.6.WHERE PROVIDED, FLOOR PLANS PROVIDING EMERGENCY PROCEDURES INFORMATION IN ACCORDANCE WITH TITLE 19 SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-703.5.6. STROKE THICKNESS. STROKE THICKNESS OF THE UPPERCASE LETTER "I" SHALL BE 10 PERCENT MINIMUM AND 20 PERCENT MAXIMUM OF THE HEIGHT OF THE CHARACTER. CHARACTER SPACING. CHARACTER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSEST POINTS OF ADJACENT CHARACTERS, EXCLUDING WORD SPACES. SPACING BETWEEN INDIVIDUAL CHARACTERS SHALL BE 10 PERCENT MINIMUM AND 35 PERCENT MAXIMUM OF CHARACTER HEIGHT. LINE SPACING. SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF CHARACTERS WITHIN A MESSAGE SHALL BE 135 PERCENT MINIMUM AND 170 PERCENT MAXIMUM OF THE CHARACTER HEIGHT. FORMAT. TEXT SHALL BE IN A HORIZONTAL FORMAT. PICTOGRAMS. PICTOGRAMS SHALL COMPLY WITH SECTION 11B-703.6. PICTOGRAM FIELD. PICTOGRAMS SHALL HAVE A FIELD HEIGHT OF 6 INCHES (152 MM) MINIMUM. CHARACTERS AND BRAILLE SHALL NOT BE LOCATED IN THE PICTOGRAM FIELD. TABLE 11B-.5.5 VISUAL CHARACTER HEIGHT HEIGHT TO FINISH FLOOR OR GROUND FROM BASELINE OF CHARACTER 40 INCHES (1016 MM) TO LESS THAN OR EQUAL TO 70 INCHES (1778 MM) HORIZONTAL VIEWING DISTANCE 72 INCHES (1829 MM) AND GREATER LESS THAN 72 INCHES (1829 MM) 2 INCHES (51 MM) 5/8 INCH (15.9 MM), PLUS 1/8 INCH (3.2 MM) PER FOOT (305 MM) OF VIEWING DISTANCE ABOVE 72 INCHES (1829 MM) MINIMUM CHARACTER HEIGHT 5/8 INCH (15.9 MM) 2 INCHES (51 MM), PLUS 1/8 INCH (3.2 MM) PER FOOT (305 MM) OF VIEWING DISTANCE ABOVE 180 INCHES (4572 MM) 3 INCHES (76 MM) 3 INCHES (76 MM), PLUS 1/8 INCH (3.2 MM) PER FOOT (305 MM) OF VIEWING DISTANCE ABOVE 21 FEET (6401 MM) 21 FEET (6401 MM) AND GREATER LESS THAN 21 FEET (6401 MM) 180 INCHES (4572 MM) AND GREATER LESS THAN 180 INCHES (4572 MM) GREATER THAN 70 INCHES (1778 MM) TO LESS THAN OR EQUAL TO 120 INCHES (3048 MM) GREATER THAN 120 INCHES (3048 MM) WHERE PROVIDED, FLOOR PLANS PROVIDING EMERGENCY PROCEDURES INFORMATION IN ACCORDANCE WITH TITLE 19 SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 1 1B-703.5.5. EXCEPTION: 11B-703.5.5 CHARACTER HEIGHT. MINIMUM CHARACTER HEIGHT SHALL COMPLY WITH TABLE 11 B-703.5.5. VIEWING DISTANCE SHALL BE MEASURED AS THE HORIZONTAL DISTANCE BETWEEN THE CHARACTER AND AN OBSTRUCTION PREVENTING FURTHER APPROACH TOWARDS THE SIGN. CHARACTER HEIGHT SHALL BE BASED ON THE UPPERCASE LETTER "I". 11B-703.5.3 CHARACTER PROPORTIONS. CHARACTERS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER "0" IS 60 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE UPPERCASE LETTER "I". STYLE. CHARACTERS SHALL BE CONVENTIONAL IN FORM. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY DECORATIVE, OR OF OTHER UNUSUAL FORMS. FINISH AND CONTRAST. CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. VISUAL CHARACTERS. VISUAL CHARACTERS SHALL COMPLY WITH SECTION 11B-703.5. 11B-703.5.4 11B-703.5.2 11B-703.5.1 11B-703.5 EXCEPTION:WHERE VISUAL CHARACTERS COMPLY WITH SECTION 11B-703.2 AND ARE ACCOMPANIED BY BRAILLE COMPLYING WITH SECTION 11B-703.3, THEY SHALL NOT BE REQUIRED TO COMPLY WITH SECTIONS 11B-703.5.2 THROUGH 11B-703.5.6, 11B-703.5.8 AND 11B-703.5.9. CASE. CHARACTERS SHALL BE UPPERCASE OR LOWERCASE OR A COMBINATION OF BOTH. EXCEPTION:RESERVED. BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18 INCHES (457 MM) MINIMUM BY 18 INCHES (457 MM) MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 OPEN POSITION. WHERE PERMANENT IDENTIFICATION SIGNAGE IS PROVIDED FOR ROOMS AND SPACES THEY SHALL BE LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE ENTERS THE ROOM OR SPACE. SIGNS THAT IDENTIFY EXITS SHALL BE LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE EXITS THE ROOM OR SPACE. LOCATION. WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONGSIDE THE DOOR AT THE LATCH SIDE. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO THE RIGHT OF THE RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE AT THE LATCH SIDE OF A SINGLE DOOR OR AT THE RIGHT SIDE OF DOUBLE DOORS, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL. SIGNS CONTAINING TACTILE CHARACTERS SHALL EXCEPTION: 11 B-703.4.1 11B-703.4 INSTALLATION HEIGHT AND LOCATION. SIGNS WITH TACTILE CHARACTERS SHALL COMPLY WITH SECTION 11B-703.4. HEIGHT ABOVE FINISH FLOOR OR GROUND. TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES (1219 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST BRAILLE CELLS AND 60 INCHES (1524 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS. TACTILE CHARACTERS FOR ELEVATOR CAR CONTROLS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11 B703.4.1. EXCEPTION: 11B-703.3.2 POSITION. BRAILLE SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT IN A HORIZONTAL FORMAT, FLUSH LEFT OR CENTERED. IF TEXT IS MULTI-LINED, BRAILLE SHALL BE PLACED BELOW THE ENTIRE TEXT. BRAILLE SHALL BE SEPARATED 3/8 INCH (9.5 MM) MINIMUM AND 1/2 INCH (12.7 MM) MAXIMUM FROM ANY OTHER TACTILE CHARACTERS AND 3/8 INCH (9.5 MM) MINIMUM FROM RAISED BORDERS AND DECORATIVE ELEMENTS. BRAILLE PROVIDED ON ELEVATOR CAR CONTROLS SHALL BE SEPARATED 3/ 16 INCH (4.8 MM) MINIMUM AND SHALL BE LOCATED EITHER DIRECTLY BELOW THE CORRESPONDING RAISED CHARACTERS OR SYMBOLS. MEASUREMENT RANGE DOT BASE DIAMETER DISTANCE BETWEEN TWO DOTS IN THE SAME CELLS ¹ DISTANCE BETWEEN CORRESPONDING DOTS IN ADJACENT CELLS ¹ DOT HEIGHT DISTANCE BETWEEN TWO CORRESPONDING DOTS FROM ONE CELL DIRECTLY BELOW ¹ MINIMUM IN INCHES MAXIMUM IN INCHES 0.059" (1.5 MM) TO 0.063" (1.6 MM) 0.100" (2.5 MM) 0.300" (7.6 MM) 0.025" (0.6 MM) TO 0.037" (0.9 MM) 0.395" (10.0 MM) TO 0.400" (10.2 MM) 1. Measured center to center. 11B-703.3.1 DIMENSIONS AND CAPITALIZATION. BRAILLE DOTS SHALL HAVE A DOMED OR ROUNDED SHAPE AND SHALL COMPLY WITH TABLE 11 B-703.3.1. THE INDICATION OF AN UPPERCASE LETTER OR LETTERS SHALL ONLY BE USED BEFORE THE FIRST WORD OF SENTENCES, PROPER NOUNS AND NAMES, INDIVIDUAL LETTERS OF THE ALPHABET, INITIALS, AND ACRONYMS 11B-703.3 BRAILLE. BRAILLE SHALL BE CONTRACTED (GRADE 2) AND SHALL COMPLY WITH SECTIONS 11 B-703.3 AND 11 B-703.4. 11B-703.2.9 FORMAT. TEXT SHALL BE IN A HORIZONTAL FORMAT. 11B-703.2.8 LINE SPACING. SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF RAISED CHARACTERS WITHIN A MESSAGE SHALL BE 135 PERCENT MINIMUM AND 170 PERCENT MAXIMUM OF THE RAISED CHARACTER HEIGHT 11 B-703.2.7 CHARACTER SPACING. CHARACTER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSEST POINTS OF ADJACENT RAISED CHARACTERS WITHIN A MESSAGE, EXCLUDING WORD SPACES. WHERE CHARACTERS HAVE RECTANGULAR CROSS SECTIONS, SPACING BETWEEN INDIVIDUAL RAISED CHARACTERS SHALL BE 1/8 INCH (3.2 MM) MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAXIMUM. WHERE CHARACTERS HAVE OTHER CROSS SECTIONS, SPACING BETWEEN INDIVIDUAL RAISED CHARACTERS SHALL BE 1/16 INCH (1.6 MM) MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAXIMUM AT THE BASE OF THE CROSS SECTIONS, AND 1/8 INCH (3.2 MM) MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAXIMUM AT THE TOP OF THE CROSS SECTIONS. CHARACTERS SHALL BE SEPARATED FROM RAISED BORDERS AND DECORATIVE ELEMENTS \ INCH (9.5 MM) MINIMUM 11B-703.2.6 STROKE THICKNESS. STROKE THICKNESS OF THE UPPERCASE LETTER "I" SHALL BE 15 PERCENT MAXIMUM OF THE HEIGHT OF THE CHARACTER. EXCEPTION: RESERVED. 11B-703.2.5 CHARACTER HEIGHT. CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASELINE OF THE CHARACTER SHALL BE 5/8 INCH (15.9 MM) MINIMUM AND 2 INCHES (51 MM) MAXIMUM BASED ON THE HEIGHT OF THE UPPERCASE LETTER "I". 11 B-703.2.3 STYLE. CHARACTERS SHALL BE SANS SERIF. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY DECORATIVE, OR OF OTHER UNUSUAL FORMS. 11 B-703.2.4 CHARACTER PROPORTIONS. CHARACTERS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER "0" IS 60 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE UPPERCASE LETTER "I". 11 B-703.2.2 CASE. CHARACTERS SHALL BE UPPERCASE. 11B-703.2.1 DEPTH. RAISED CHARACTERS SHALL BE 1/ 32 INCH (0.8 MM) MINIMUM ABOVE THEIR BACKGROUND 11B-703.2 RAISED CHARACTERS. RAISED CHARACTERS SHALL COMPLY WITH SECTION 11 B-703.2 AND SHALL BE DUPLICATED IN BRAILLE COMPLYING WITH SECTION 11 B-703.3. RAISED CHARACTERS SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 11 B-703.4. 11B-703.1.1.2 INSPECTION. SIGNS AND IDENTIFICATION DEVICES SHALL BE FIELD INSPECTED AFTER INSTALLATION AND APPROVED BY THE ENFORCING AGENCY PRIOR TO THE ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER CHAPTER 1, DIVISION II, SECTION 111, OR FINAL APPROVAL WHERE NO CERTIFICATE OF OCCUPANCY IS ISSUED. THE INSPECTION SHALL INCLUDE, BUT NOT BE LIMITED TO, VERIFICATION THAT BRAILLE DOTS AND CELLS ARE PROPERLY SPACED AND THE SIZE, PROPORTION AND TYPE OF RAISED CHARACTERS ARE IN COMPLIANCE WITH THESE REGULATIONS. 11B-703.1.1.1 PLAN REVIEW. PLANS, SPECIFICATIONS OR OTHER INFORMATION INDICATING COMPLIANCE WITH THESE REGULATIONS SHALL BE SUBMITTED TO THE ENFORCING AGENCY FOR REVIEW AND APPROVAL 11B-703.1.1 PLAN REVIEW AND INSPECTION. SIGNS AS SPECIFIED IN SECTION 11 B-703, OR IN OTHER SECTIONS OF THIS CODE, WHEN INCLUDED IN THE CONSTRUCTION OF NEW BUILDINGS OR FACILITIES, OR WHEN INCLUDED, ALTERED OR REPLACED DUE TO ADDITIONS, ALTERATIONS OR RENOVATIONS TO EXISTING BUILDINGS OR FACILITIES, AND WHEN A PERMIT IS REQUIRED, SHALL COMPLY WITH SECTIONS 11B-703.1.1.1 AND 11B-703.1.1.2. GENERAL. SIGNS SHALL COMPLY WITH SECTION 11 B703. WHERE BOTH VISUAL AND TACTILE CHARACTERS ARE REQUIRED, EITHER ONE SIGN WITH BOTH VISUAL AND TACTILE CHARACTERS, OR TWO SEPARATE SIGNS, ONE WITH VISUAL, AND ONE WITH TACTILE CHARACTERS, SHALL BE PROVIDED. 11B-703.1 6" M I N 15 2 45 . 0 0 ° 1' - 6" MIN 457 1' - 6 " M I N 45 7 5/ 8 " M I N - 2 " M A X 15 . 9 - 5 1 no raised dot raised dot blank cell space between words single braille cell distance between dots in the same cell base diameter distance between corresponding dots in adjacent cells distance between dots in the same cell distance between corresponding dots from one cell directly below not in pictogram field 1B-703.4.2 AREA OF REFUGE 4' - 0 " M I N 12 1 9 centered on tactile characters 5' - 0 " M I N 15 2 4 TABLE 11B-703.3.1 BRAILLE DIMENSIONS 11B-703 SIGNS FIGURE 703.7.2.3 VOLUME CONTROL TELEPHONE FIGURE 703.7.2.5 CLEANER AIR SYMBOL Cleaner Air FIGURE 703.7.2.4 INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS FIGURE 703.7.2.2 INTERNATIONAL TTY SYMBOL FIGURE 703.7.2.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY FIGURE 703.6.1 PICTOGRAM FIELD MEN AREA OF REFUGE FIGURE 703.4.2 LOCATION OF TACTILE SIGNS AT DOORS FIGURE 703.4.1 HEIGHT OF TACTILE CHARACTERS ABOVE FLOOR OR GROUND AREA OF REFUGE 3/ 8 " MI N 9. 5 3/ 8 " - 1 / 2 " 9. 5 - 1 2 . 7 FIGURE 703.3.2 POSITION OF BRAILLE . . . . . FIGURE 703.3.1 BRAILLE MEASUREMENT FIGURE 703.2.5 HEIGHT OF RAISED CHARACTERS LIBRARY 11 B-705.1 11 B-705.1.1 11 B-705.1.1.1 11 B-705.1.1.2 EXCEPTION: GENERAL. DETECTABLE WARNINGS SHALL CONSIST OF A SURFACE OF TRUNCATED DOMES AND SHALL COMPLY WITH SECTION11 B-705. DOME SIZE. TRUNCATED DOMES IN A DETECTABLE WARNING SURFACE SHALL HAVE A BASE DIAMETER OF 0.9 INCH (22.9 MM) MINIMUM AND 0.92 INCH (23.4 MM) MAXIMUM, A TOP DIAMETER OF 0.45 INCH (11.4 MM) MINIMUM AND 0.47 INCH (11.9 MM) MAXIMUM, AND A HEIGHT OF 0.2 INCH (5.1 MM). DOME SPACING. TRUNCATED DOMES IN A DETECTABLE WARNING SURFACE SHALL HAVE A CENTER-TO-CENTER SPACING OF 2.3 INCHES (58 MM) MINIMUM AND 2.4 INCHES (61 MM) MAXIMUM, AND A BASE-TO-BASE SPACING OF 0.65 INCH (16.5 MM) MINIMUM, MEASURED BETWEEN THE MOST ADJACENT DOMES ON A SQUARE GRID. WHERE INSTALLED IN A RADIAL PATTERN, TRUNCATED DOMES SHALL HAVE A CENTER-TO-CENTER SPACING OF 1.6 INCHES (41 MM) MINIMUM TO 2.4 INCHES (61 MM) MAXIMUM. 11 B-705.1.1.3 CONTRAST. DETECTABLE WARNING SURFACES SHALL CONTRAST VISUALLY WITH ADJACENT WALKING SURFACES EITHER LIGHT-ON-DARK, OR DARK-ON-LIGHT. THE MATERIAL USED TO PROVIDE CONTRAST SHALL BE AN INTEGRAL PART OF THE SURFACE. CONTRAST SHALL BE DETERMINED BY: CONTRAST= [(BL-B2)/B1] X 100 PERCENT WHERE B1 = LIGHT REFLECTANCE VALUE (LRV) OF THE LIGHTER AREA AND B2 = LIGHT REFLECTANCE VALUE (LRV) OF THE DARKER AREA. EXCEPTION:WHERE THE DETECTABLE WARNING SURFACE DOES NOT ADEQUATELY CONTRAST WITH ADJACENT SURFACES, A 1 INCH (25 MM) WIDE BLACK STRIP SHALL SEPARATE YELLOW DETECTABLE WARNING FROM ADJACENT SURFACES 11 B-705.1.1.4 RESILIENCY. DETECTABLE WARNING SURFACES SHALL DIFFER FROM ADJOINING SURFACES IN RESILIENCY OR SOUND-ON-CANE CONTACT. EXCEPTION:DETECTABLE WARNING SURFACES AT CURB RAMPS, ISLANDS OR CUT-THROUGH MEDIANS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11 B-705.1.1.4. 11B-705.1.1.3.1 COLOR. DETECTABLE WARNING SURFACES SHALL BE YELLOW CONFORMING TO FS 33538 OF FEDERAL STANDARD 595C. 11B-705.1.2 LOCATIONS. DETECTABLE WARNINGS AT THE FOLLOWING LOCATIONS SHALL COMPLY WITH SECTION 11 B-705.1 11B-705.1.2.1 PLATFORM EDGES. DETECTABLE WARNING SURFACES AT PLATFORM BOARDING EDGES SHALL BE 24 INCHES (610 MM) WIDE AND SHALL EXTEND THE FULL LENGTH OF THE PUBLIC USE AREAS OF THE PLATFORM. 11B-705.1.2.2 CURB RAMPS. DETECTABLE WARNINGS AT CURB RAMPS SHALL EXTEND 36 INCHES (914 MM) IN THE DIRECTION OF TRAVEL. DETECTABLE WARNINGS SHALL EXTEND THE FULL WIDTH OF THE RAMP RUN EXCLUDING ANY FLARED SIDES. DETECTABLE WARNINGS SHALL BE LOCATED SO THE EDGE NEAREST THE CURB IS 6 INCHES ( 152 MM) MINIMUM AND 8 INCHES (203 MM) MAXIMUM FROM THE LINE AT THE FACE OF THE CURB MARKING THE TRANSITION BETWEEN THE CURB AND THE GUTTER, STREET OR HIGHWAY. EXCEPTION:ON PARALLEL CURB RAMPS, DETECTABLE WARNINGS SHALL BE PLACED ON THE TURNING SPACE AT THE FLUSH TRANSITION BETWEEN THE STREET AND SIDEWALK. 11B-705.1.2.3 ISLANDS OR CUT-THROUGH MEDIANS. DETECTABLE WARNINGS AT PEDESTRIAN ISLANDS OR CUT THROUGH MEDIANS SHALL BE 36 INCHES (914 MM) MINIMUM IN DEPTH EXTENDING THE FULL WIDTH OF THE PEDESTRIAN PATH OR CUT-THROUGH, PLACED AT THE EDGES OF THE PEDESTRIAN ISLAND OR CUT-THROUGH MEDIAN, AND SHALL BE SEPARATED BY 24 INCHES (610 MM) MINIMUM OF WALKING SURFACE WITHOUT DETECTABLE WARNINGS. EXCEPTION:DETECTABLE WARNINGS SHALL BE 24 INCHES (610 MM) MINIMUM IN DEPTH AT PEDESTRIAN ISLANDS OR CUT-THROUGH MEDIANS THAT ARE LESS THAN 96 INCHES (2438 MM) IN LENGTH IN THE DIRECTION OF PEDESTRIAN TRAVEL. 11B-705.1.2.4 BUS STOPS. WHEN DETECTABLE WARNINGS ARE PROVIDED AT BUS STOP PADS, IT SHALL BE 36 INCHES (914 MM) IN WIDTH. 11B-705.1.2.5 11B-705.1.2.6 11B-705.1.2.7 HAZARDOUS VEHICULAR AREAS. DETECTABLE WARNINGS AT HAZARDOUS VEHICULAR AREAS SHALL BE 36 INCHES (914 MM) IN WIDTH REFLECTING POOLS. WHEN DETECTABLE WARNINGS ARE PROVIDED AT REFLECTING POOLS, IT SHALL BE 24 INCHES (610 MM) MINIMUM AND 36 INCHES (914 MM) MAXIMUM IN WIDTH. TRACK CROSSINGS. DETECTABLE WARNINGS AT TRACK CROSSINGS SHALL BE 36 INCHES (914 MM) IN THE DIRECTION OF PEDESTRIAN TRAVEL AND EXTEND THE FULL WIDTH OF THE CIRCULATION PATH. 11B-705.2 DETECTABLE DIRECTIONAL TEXTURE. DETECTABLE DIRECTIONAL TEXTURE AT TRANSIT BOARDING PLATFORMS SHALL COMPLY WITH FIGURE 11 B-705.2 AND SHALL BE 0.1 INCH (2.5 MM) IN HEIGHT THAT TAPERS OFF TO 0.04 INCH (1.0 MM), WITH BARS RAISED 0.2 INCH (5.1 MM) FROM THE SURFACE. THE RAISED BARS SHALL BE 1.3 INCHES (33 MM) WIDE AND 3 INCHES (76 MM) FROM CENTER-TOCENTER OF EACH BAR. THIS SURFACE SHALL DIFFER FROM ADJOINING WALKING SURFACES IN RESILIENCY OR SOUND-ON-CANE CONTACT. THE COLOR SHALL BE YELLOW CONFORMING TO FEDERAL COLOR NO. 33538. THIS SURFACE WILL BE PLACED DIRECTLY BEHIND THE YELLOW DETECTABLE WARNING TEXTURE SPECIFIED IN SECTION 11 B705.1.2.1, ALIGNING WITH ALL DOORS OF THE TRANSIT VEHICLES WHERE PASSENGERS WILL EMBARK. THE WIDTH OF THE DIRECTIONAL TEXTURE SHALL BE EQUAL TO THE WIDTH OF THE TRANSIT VEHICLE'S DOOR OPENING. THE DEPTH OF THE TEXTURE SHALL NOT BE LESS THAN 36 INCHES (914 MM). 11B-705.3 PRODUCT APPROVAL. ONLY APPROVED DSA-AC DETECTABLE WARNING PRODUCTS AND DIRECTIONAL SURFACES SHALL BE INSTALLED AS PROVIDED IN THE CALIFORNIA CODE OF REGULATIONS (CCR), TITLE 24, PART 1, CHAPTER 5, ARTICLES 2, 3 AND 4. REFER TO CCR TITLE 24, PART 12, CHAPTER 11B, SECTION 1211 B.205 FOR BUILDING AND FACILITY ACCESS SPECIFICATIONS FOR PRODUCT APPROVAL FOR DETECTABLE WARNING PRODUCTS AND DIRECTIONAL SURFACES. top diameter of 0.45" - 0.47" 11.4 - 11.9 base diameter of 0.9" - 0.92" 22.9 - 23.4 B 5. 1 0. 2" 58-61 2.3" - 2.4" 58 - 6 1 2. 3 " - 2 . 4 " 16 . 5 .6 5 " MI N 11B-705 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE DETECTABLE WARNINGS FIGURE 705.1 DETECTABLE DIRECTIONAL TEXTURE (b) plan 38 1 1/2" MIN 229 3"* MIN 23 .9" 33 1.3" 38 1- 1 / 2 " MI N 22 9 9" * MI N 38 1- 1 / 2 " MI N * industry standard for overall bar length is 11-1/4" - 11-1/2" (286 mm-292 mm) (a) elevation (enlarged) 5. 1 0. 2 "  tapered edges where exposed FIGURE 705.1 SIZE AND SPACING OF TRUNCATED DOMES (b) plan (a) elevation (enlarged) 11 B-706.1 11 B-706.2 11 B-706.3 11 B-706.4 11 B-706.5 11 B-706.6 GENERAL. ASSISTIVE LISTENING SYSTEMS REQUIRED IN ASSEMBLY AREAS, CONFERENCE AND MEETING ROOMS SHALL COMPLY WITH SECTION 11 B-706. RECEIVER JACKS. RECEIVERS REQUIRED FOR USE WITH AN ASSISTIVE LISTENING SYSTEM SHALL INCLUDE A 1/8 INCH (3.2 MM) STANDARD MONO JACK. RECEIVER HEARING-AID COMPATIBILITY. RECEIVERS REQUIRED TO BE HEARING-AID COMPATIBLE SHALL INTERFACE WITH TELECOILS IN HEARING AIDS THROUGH THE PROVISION OF NECK LOOPS. SOUND PRESSURE LEVEL. ASSISTIVE LISTENING SYSTEMS SHALL BE CAPABLE OF PROVIDING A SOUND PRESSURE LEVEL OF 110 DB MINIMUM AND 118 DB MAXIMUM WITH A DYNAMIC RANGE ON THE VOLUME CONTROL OF 50 DB. SIGNAL-TO-NOISE RATIO. THE SIGNAL-TO-NOISE RATIO FOR INTERNALLY GENERATED NOISE IN ASSISTIVE LISTENING SYSTEMS SHALL BE 18 DB MINIMUM. PEAK CLIPPING LEVEL. PEAK CLIPPING SHALL NOT EXCEED 18 DB OF CLIPPING RELATIVE TO THE PEAKS OF SPEECH. 11B-706 ASSISTIVE LISTENING SYSTEMS 11B-708.1 11B-708.2 11B-708.3 11B-708.4 11B-708.4.1 11B-708.4.2 GENERAL. TWO-WAY COMMUNICATION SYSTEMS SHALL COMPLY WITH SECTION 11 B-708. AUDIBLE AND VISUAL INDICATORS. THE SYSTEM SHALL PROVIDE BOTH AUDIBLE AND VISUAL SIGNALS. HANDSETS. HANDSET CORDS, IF PROVIDED, SHALL BE 29 INCHES (737 MM) LONG MINIMUM. RESIDENTIAL DWELLING UNIT COMMUNICATION SYSTEMS. COMMUNICATIONS SYSTEMS BETWEEN A RESIDENTIAL DWELLING UNIT AND A SITE, BUILDING, OR FLOOR ENTRANCE SHALL COMPLY WITH SECTION 11 B-708.4. COMMON USE OR PUBLIC USE SYSTEM INTERFACE. THE COMMON USE OR PUBLIC USE SYSTEM INTERFACE SHALL INCLUDE THE CAPABILITY OF SUPPORTING VOICE AND TTY COMMUNICATION WITH THE RESIDENTIAL DWELLING UNIT INTERFACE. RESIDENTIAL DWELLING UNIT INTERFACE. THE RESIDENTIAL DWELLING UNIT SYSTEM INTERFACE SHALL INCLUDE A TELEPHONE JACK CAPABLE OF SUPPORTING VOICE AND TTY COMMUNICATION WITH THE COMMON USE OR PUBLIC USE SYSTEM INTERFACE. 11B-708 TWO-WAY COMMUNICATION SYSTEMS 11B-804.1 GENERAL. KITCHENS AND KITCHENETTES SHALL COMPLY WITH SECTION 11 B-804 11B-804.2 CLEARANCE. WHERE A PASS THROUGH KITCHEN IS PROVIDED, CLEARANCES SHALL COMPLY WITH SECTION 11B-804.2.1. WHERE A U-SHAPED KITCHEN IS PROVIDED, CLEARANCES SHALL COMPLY WITH SECTION 11 B-804.2.2. EXCEPTION:SPACES THAT DO NOT PROVIDE A COOKTOP OR CONVENTIONAL RANGE SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-804.2. 11B-804.2.1 PASS THROUGH KITCHEN. IN PASS THROUGH KITCHENS WHERE COUNTERS, APPLIANCES OR CABINETS ARE ON TWO OPPOSING SIDES, OR WHERE COUNTERS, APPLIANCES OR CABINETS ARE OPPOSITE A PARALLEL WALL, CLEARANCE BETWEEN ALL OPPOSING BASE CABINETS, COUNTER TOPS, APPLIANCES, OR WALLS WITHIN KITCHEN WORK AREAS SHALL BE 40 INCHES (1016 MM) MINIMUM. PASS THROUGH KITCHENS SHALL HAVE TWO ENTRIES. 11B-804.2.2 U-SHAPED. IN U-SHAPED KITCHENS ENCLOSED ON THREE CONTIGUOUS SIDES, CLEARANCE BETWEEN ALL OPPOSING BASE CABINETS, COUNTER TOPS, APPLIANCES, OR WALLS WITHIN KITCHEN WORK AREAS SHALL BE 60 INCHES (1524 MM) MINIMUM. 11B-804.3 KITCHEN WORK SURFACE. IN RESIDENTIAL DWELLING UNITS REQUIRED TO COMPLY WITH SECTION 11 B-809, AT LEAST ONE 30 INCHES (762 MM) WIDE MINIMUM SECTION OF COUNTER SHALL PROVIDE A KITCHEN WORK SURFACE THAT COMPLIES WITH SECTION 11 B-804.3. 11B-804.3.1 EXCEPTION: CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR SPACE COMPLYING WITH SECTION 11 B-305 POSITIONED FOR A FORWARD APPROACH SHALL BE PROVIDED. THE CLEAR FLOOR OR GROUND SPACE SHALL BE CENTERED ON THE KITCHEN WORK SURFACE AND SHALL PROVIDE KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11 B-306. CABINETRY SHALL BE PERMITTED UNDER THE KITCHEN WORK SURFACE PROVIDED THAT ALL OF THE FOLLOWING CONDITIONS ARE MET: (A) THE CABINETRY CAN BE REMOVED WITHOUT REMOVAL OR REPLACEMENT OF THE KITCHEN WORK SURFACE; (B) THE FINISH FLOOR EXTENDS UNDER THE CABINETRY; AND (C) THE WALLS BEHIND AND SURROUNDING THE CABINETRY ARE FINISHED. 11B-804.3.2 HEIGHT. THE KITCHEN WORK SURFACE SHALL BE 34 INCHES ( 864 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. EXCEPTION:A COUNTER THAT IS ADJUSTABLE TO PROVIDE A KITCHEN WORK SURFACE AT VARIABLE HEIGHTS, 29 INCHES (737 MM) MINIMUM AND 36 INCHES (914 MM) MAXIMUM, SHALL BE PERMITTED. 11B-804.3.3 EXPOSED SURFACES. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER THE WORK SURFACE COUNTERS. 11B-804.4 SINKS. SINKS SHALL COMPLY WITH SECTION 11B-606. STORAGE. AT LEAST 50 PERCENT OF SHELF SPACE IN STORAGE FACILITIES SHALL COMPLY WITH SECTION 11B-811. 11B-804.5 11B-804.6 APPLIANCES. WHERE PROVIDED, KITCHEN APPLIANCES SHALL COMPLY WITH SECTION 1 B-804.6. 11B-804.6.1 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH SECTION 1 B-305 SHALL BE PROVIDED AT EACH KITCHEN APPLIANCE. CLEAR FLOOR OR GROUND SPACES SHALL BE PERMITTED TO OVERLAP. 11B-804.6.2 OPERABLE PARTS. ALL APPLIANCE CONTROLS SHALL COMPLY WITH SECTION 11B-309. EXCEPTIONS:APPLIANCE DOORS AND DOOR LATCHING DEVICES SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-309.4. 1. 2.BOTTOM-HINGED APPLIANCE DOORS, WHEN IN THE OPEN POSITION, SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-309.3. 11B-804.6.3 DISHWASHER. CLEAR FLOOR OR GROUND SPACE SHALL BE POSITIONED ADJACENT TO THE DISHWASHER DOOR. THE DISHWASHER DOOR, IN THE OPEN POSITION, SHALL NOT OBSTRUCT THE CLEAR FLOOR OR GROUND SPACE FOR THE DISHWASHER OR THE SINK. 11B-804.6.4 RANGE OR COOKTOP. WHERE A FORWARD APPROACH IS PROVIDED, THE CLEAR FLOOR OR GROUND SPACE SHALL PROVIDE KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11 B-306. WHERE KNEE AND TOE SPACE IS PROVIDED, THE UNDERSIDE OF THE RANGE OR COOKTOP SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PREVENT BURNS, ABRASIONS, OR ELECTRICAL SHOCK. THE LOCATION OF CONTROLS SHALL NOT REQUIRE REACHING ACROSS BURNERS. 11B-804.6.5 OVEN. OVENS SHALL COMPLY WITH SECTION 11B804.6.5. 11B-804.6.5.1 SIDE-HINGED DOOR OVENS. SIDE-HINGED DOOR OVENS SHALL HAVE THE WORK SURFACE REQUIRED BY SECTION 11B-804.3 POSITIONED ADJACENT TO THE LATCH SIDE OF THE OVEN DOOR. 11B-804.6.5.2 BOTTOM-HINGED DOOR OVENS. BOTTOM HINGED DOOR OVENS SHALL HAVE THE WORK SURFACE REQUIRED BY SECTION 11 B-804.3 POSITIONED ADJACENT TO ONE SIDE OF THE DOOR. 11B-804.6.5.3 CONTROLS. OVENS SHALL HAVE CONTROLS ON FRONT PANELS. 11B-804.6.6 REFRIGERATOR/FREEZER. COMBINATION REFRIGERATORS AND FREEZERS SHALL HAVE AT LEAST 50 PERCENT OF THE FREEZER SPACE 54 INCHES (1372 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. THE CLEAR FLOOR OR GROUND SPACE SHALL BE POSITIONED FOR A PARALLEL APPROACH TO THE SPACE DEDICATED TO A REFRIGERATOR/FREEZER WITH THE CENTERLINE OF THE CLEAR FLOOR OR GROUND SPACE OFFSET 24 INCHES (610 MM) MAXIMUM FROM THE CENTERLINE OF THE DEDICATED SPACE. 1016 3'-4" MIN 1524 5'-0" MIN 1524 5'-0" MIN 11B-804 KITCHENS AND KITCHENETTES FIGURE 804.2.2 U-SHAPED KITCHENS (b)(a) FIGURE 804.2.1 PASS THROUGH KITCHENS GENERAL. STORAGE SHALL COMPLY WITH SECTION JIB811. CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH SECTION 11 B-305 SHALL BE PROVIDED. HEIGHT. STORAGE ELEMENTS SHALL COMPLY WITH AT LEAST ONE OF THE REACH RANGES SPECIFIED IN SECTION 11B-308. OPERABLE PARTS. OPERABLE PARTS SHALL COMPLY WITH SECTION 11B-309. 11B-811 STORAGE SCOPE. THE PROVISIONS OF DIVISION 9 SHALL APPLY WHERE REQUIRED BY DIVISION 2 OR WHERE REFERENCED BY A REQUIREMENT IN THIS CHAPTER. 11B-901 GENERAL DIVISION 9: BUILT-IN ELEMENTS 11B-902.1 EXCEPTION: GENERAL. DINING SURFACES AND WORK SURFACES SHALL COMPLY WITH SECTIONS 11B-902.2 AND 11B-902.3. DINING SURFACES AND WORK SURFACES FOR CHILDREN'S USE SHALL BE PERMITTED TO COMPLY WITH SECTION 11B902.4. 11B-902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR SPACE COMPLYING WITH SECTION 11 B-305 POSITIONED FOR A FORWARD APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11 B-306 SHALL BE PROVIDED. 11B-902.3 HEIGHT. THE TOPS OF DINING SURFACES AND WORK SURFACES SHALL BE 28 INCHES (711 MM) MINIMUM AND 34 INCHES ( 864 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. 11B-902.4 DINING SURFACES AND WORK SURFACES FOR CHILDREN'S USE. ACCESSIBLE DINING SURFACES AND WORK SURFACES FOR CHILDREN'S USE SHALL COMPLY WITH SECTION 11B-902.4. EXCEPTION:DINING SURFACES AND WORK SURFACES THAT ARE USED PRIMARILY BY CHILDREN 5 YEARS AND YOUNGER SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-902.4 WHERE A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH SECTION 11B305 POSITIONED FOR A PARALLEL APPROACH IS PROVIDED. 11B-902.4.1 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR SPACE COMPLYING WITH SECTION 11 B-305 POSITIONED FOR FORWARD APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11B-306 SHALL BE PROVIDED, EXCEPT THAT KNEE CLEARANCE 24 INCHES ( 610 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND SHALL BE PERMITTED. 11B-902.4.2 HEIGHT. THE TOPS OF TABLES AND COUNTERS SHALL BE 26 INCHES (660 MM) MINIMUM AND 30 INCHES (762 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. 11B-902 DINING SURFACES AND WORK SURFACES 1DIVISION 7 COMMUNICATION ELEMENTS 2DIV. 702 - FIRE ALARMS SYSTEMS 4DIV. 703 - SIGNS5DIV. 705 - DETECTABLE WARNINGS 6 DIV. 706 - ASSISTIVE LISTENING SYSTEMS 7 DIV. 708 - TWO-WAY COMMUNICATION SYSTEMS 8DIV. 804 - KITCHENS & KITCHENETTES 9DIV. 811 - STORAGE 10DIVISION 9 BUILT-IN ELEMENTS 11DIV. 902 - DINING AND WORK SURFACES A0.5g CBC 11B DIV 7-8-9 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 UP UP UP (E)70'-4" (E ) 49 ' - 2 " UP UP UP DN F. E . F.E. DN 4'-3" AL L E Y FO O T H I L L B L V D 119.58' 49 ' - 7 " (E)7'-4"7'-1" 16 ' - 2 " (N) ACCESSIBLE PARKING (E) PARKING(E) PARKING (E) PARKING(E) PARKING(E) PARKING(E) PARKING TENANT IMPROVEMENT OF (E) 3,500 SQ.FT. OFFICE BUILINDG. UP UP UP UP UP UP DN F. E . F.E. DN 4'-3" 82'-5" 55'47'-4" 3' - 1 " 3' - 0 " 55 ' WH DNDN DN DN DN 108'-4" (40'-4" + 68') 3'- 5 " DN DN 4'-3" 6'- 0 " 4'-1"11" 6'-11" 14 ' - 1 " 7' - 6 " 9'-0" (108") 8'-0" (96") 4'-3" 18 ' - 0 " 6'-0" 1'-0" 1'-11" TW+12"(MIN) 1'-0" 1'-0" 6'-0" SCALE: 3/16" = 1'-0" SITE PLAN 1 A1.0 SITE PLAN & CODE ANALYSIS (E) ACCESSIBLE PATH OF TRAVEL PROJECT SITE SITE PLAN GENERAL NOTES: 1. ACCESSIBLE PATHS OF TRAVEL SHALL HAVE A CONTINUOUS COMMON SURFACE, NOT INTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN LEVEL EXCEEDING 1/2 INCH AND SHALL BE MINIMUM OF 48 INCHES IN WIDTH. IF A WALK OR SIDEWALK HAS LESS THAN 60 INCH CLEAR WIDTH, THEN PASSING SPACES AT LEAST 60 INCHES BY 60 INCHES SHALL BE LOCATED AT REASONABLE INTERVALS NOT TO EXCEED 200 FEET. SURFACE CROSS SLOPES SHALL NOT EXCEED 1/4 INCH PER FOOT. WHEN THE SLOPE IN DIRECTION OF TRAVEL OF ANY WALK EXCEEDS ONE UNIT VERTICAL TO 20 UNITS HORIZONTAL, IT SHALL COMPLY WITH PROVISIONS OF CBC 11B-405 FOR RAMPS. 2.IF A WALK CROSSES OR ADJOINS A VEHICULAR WAY, AND THE WALKING SURFACES ARE NOT SEPARATED BY CURBS, RAILINGS OR OTHER ELEMENTS BETWEEN THE PEDESTRIAN AREA AND THE VEHICULAR AREA, THE BOUNDARY BETWEEN THE AREA SHALL BE DEFINED BY A CONTINUOUS DETECTABLE WARNING WHICH IS 36 INCHES WIDE, COMPLYING WITH CBC 11B-705.1. 3.WALKING SURFACES THAT ARE A PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH CBC SECTION 11B-403. 4.FLOOR OR GROUND SURFACES SHALL COMPLY WITH CBC SECTION 11B-302. 5.THE RUNNING SLOPE OF WALKING SURFACES SHALL NOT BE STEEPER THAN 1:20. THE CROSS SLOPE OF WALKING SURFACES SHALL NOT BE STEEPER THAN 1:48. AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 N PATH OF TRAVEL NOTE: NO ABRUPT CHANGES IN ELEVATION ALONG THE PATH OF TRAVEL SHOWN ON PLAN. THE SLOPE AND CROSS-SLOPE ALONG THE PATH OF TRAVEL SHALL NOT EXCEED 5% AND 2% RESPECTIVELY. EG.= EGRESS WINDOW / DOOR EXIT ANALYSIS: MAX. TRAVEL DISTANCE : 108'-4" < 200 ST. MAX. ALLOWED PATH OF TRAVEL (E) AREA NO CHANGE OFFICE SCALE: 3/16" = 1'-0" EGRESS PLAN-FIRST FLOOR 2SCALE: 3/16" = 1'-0" EGRESS PLAN-MEZZANINE 3 EXIT EXIT OCCUPANT LOAD : 24 OCC / 2 = 12 OCC. REQUIRED WIDTH : 12 OCC. x 0.2 = 2.4 INCH PROVIDED WIDTH : 36 INCH ALLOWED OCCUPANT LOAD CALCULATION: 3,500 SF (B OCCUPANCY) / 150 (LOAD OCC. FACTOR) TOTAL OCC. LOAD = 24 OCC OCCUPANT LOAD : 24 OCC / 2 = 12 OCC. REQUIRED WIDTH : 12 OCC. x 0.2 = 2.4 INCH PROVIDED WIDTH : 72 INCH ALLOWED DOOR PROVIDE PANIC HARDWARE 12 12 SCALE: 3/16" = 1'-0" ADA PARKING & RAMP 4 4 ACCESSIBLE PARKING SIGN, SEE A0.5e/#6-8 60 " X 6 0 " 60 " L A N D I N G ACCESSIBLE RAMP & HANDRAILS, SEE 4/A0.5c & 5/A0.5e ACCESSIBLE STALL, SEE A0.5e UP UP UP 4'-11"9'-2"9'-11"5'-0"6'- 1 1 " 14 ' - 1 " 10 ' - 4 " 22 ' - 8 " 4' - 1 1 " 22 ' - 5 " WH DNDN DN DN DN A2.0 EXISTING/ DEMOLITION PLANS AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 SCALE: 1/4" = 1'-0" EXISTING/DEMOLITION PLAN: FIRST FLOOR 1 D2 D4 D3 D1 WALL TO BE DEMOLISHED. WINDOW TO BE DEMOLISHED. DOOR TO BE DEMOLISHED. FIXTURE TO BE DEMOLISHED. 1.CONTRACTOR TO VERIFY ALL DIMENSIONS ON SITE PRIOR TO CONSTRUCTION. 2.EXISTING PLUMBING & ELECTRICAL FIXTURES, MECHANICAL DUCT WORK, T-BAR CEILING TILES, AND FLOOR FINISHES TO BE DEMOLISH. CONTRACTOR TO FIELD VERIFY EXISTING CONDITION FOR DEMOLITION SCOPE OF WORK. KEYNOTES SYMBOL DESCRIPTION DETAIL D5 STEP TO BE DEMOLISHED. LEGEND GENERAL NOTES NEW WALL-(2X6 STUD AT EXTERIOR WITH R-21 INSULATION, WHERE OCCURS, SEE TITLE 24) EXISTING WALL TO REMAIN DEMOLISHED WALL DEMOLISHED WINDOW DEMOLISHED DOOR EXISTING WINDOW TO REMAIN EXISTING DOOR TO REMAIN 1-HR. RATED WALL: SEE DETAIL 14 & 17/A6.1 (N) NEW DOOR/ WINDOW (E) EXISTING DOOR/ WINDOW (R) RELOCATED DOOR/ WINDOW NOTE: EXISTING DOORS AND WINDOW CALLED OUT USING STANDARD FORMAT (I.E. "2646" IS 2'-6" W. X 4'-6" H.) IF NO CALL-OUT E G GAS METER ELECTRICAL METER W WATER METER SCALE: 1/4" = 1'-0" EXISTING/DEMOLITION PLAN: MEZZ. LEVEL 2 D1 TYP. D1 TYP. D1 TYP. D3 TYP. D2 TYP. D2 TYP. D2 TYP. D4 TYP. D4 TYP. D1 TYP. D1 TYP. D4 TYP.D4 TYP. D5 D5 D5 D4 D4 AC CONDENSER TO BE MOVED ON ROOF AC CONDENSER TO BE MOVED ON ROOF D6 EXISTING STRIPING REMOVED D6 D6 UP UP UP UP UP UP DN F. E . F.E. DN 4'-3" 8'-5" OFFICE 104 8'-8"8'-8"8'-8"8'-8"7'-4"7'-4"9'-1" 66'-10"3'-6" 70'-4" LOUNGE 101 MEETING ROOM 102 OFFICE 105 OFFICE 106 OFFICE 107 OFFICE 108 OFFICE 109 OFFICE 110 OFFICE 111 OFFICE 119 OFFICE 120 OFFICE 121 OFFICE 122 OFFICE 123 OFFICE 124 STORAGE 126 OFFICE 125 OFFICE 117 OFFICE 116 17'-5"7'-5"7'-6"7'-6"7'-6"7'-6"7'-6"8'-0" 70'-4" HALLWAY 1 103 HALLWAY 2 118 UNISEX 114 UNISEX 115 PRINT 112 ENTRY 113 22 ' - 8 1 / 2 " 3' - 2 1 / 2 " 5' - 0 " 5' - 0 " 26 ' - 7 " 9' - 6 " 10 ' - 0 " 2' - 9 " 49 ' - 2 " 49'-2 31/32" 119'-6 31/32" 50 ' - 0 " 4' - 0 " 10 ' - 7 " 4' - 2 " 8'- 6 " 4' - 7 1 / 2 " 4' - 9 " 9'- 4 1 / 2 " 3' - 3 " 22 ' - 0 " 50 ' - 4 " 49'-2 31/32" 119'-7" S3 A4.2 S1 A4.2 S2 A4.2 S4 A4.2 S8 A4.1 1 A4.1 2 A4.1 S7 A4.3 S6 A4.3 S5 A4.3 5" 5" 18 ' - 9 " S7 A4.3 1' - 0 " EQ EQ EQ EQ 8'-2" CLR.8'-2" CLR.8'-2" CLR.8'-2" CLR.8'-2" CLR.8'-2" CLR.6'-10" CLR.6'-10" CLR. 5'-0"7'-8"7'-7" 7'-7"16'-6" 12 ' - 6 " 5' - 0 " 5' - 0 " 4' - 2 " 6'-8" 12 ' - 5 1 / 2 " 7'- 2 " 8' - 8 " 5'- 6 " 16'-9"8" 7' - 3 " 3' - 1 " 3'-0" 2' - 0 " 24 " M A X 2' - 0 " 24 " M A X 2'-0" 12 ' - 4 " TY P . 2'-6" TYP. 1'-6" 1'-0" 4'-11" 7'-7" 29'-4" 6" 7'- 2 " 5'-2" 4'-6" TYP. 6'- 6 " 3'-8"4'-6"3'-8"4'-6"3'-8"4'-6"3'-8"4'-6"3'-8"4'-6" 4'-5"4'-5" 3'-8"4'-6" 2'-5"2'-5" 2'-6"2'-6"2'-6"2'-6"2'-6" 4'-11" 5'-2" A2.1 FLOOR PLAN: FIRST FLOOR AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A LI F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 SCALE: 1/4" = 1'-0" FLOOR PLAN: FIRST FLOOR 1 ELECTRICAL PANEL 200 AMPS. KEEP 3 FEET CLEAR FROM FACE OF ELECTRICAL PANEL TO ANY WALL SURFACE OR OBSTRUCTION TV WALL TOILET GRAB BAR UNDER COUNTER REFRIGERATOR SYMBOL DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 DETAIL 13 14 15 DISHWAHSER COAT HOOKS COUNTERTOP DESCRIPTIONSYMBOLTYPE (E)WALL W1 W2 W3 GLASS PARTITION WALL(FULL HEIGHT) NOTE: THE CODE REQUIRES THAT EQUIPMENT AND DUCT SIZING BE DONE ACCORDING TO ACCA MANUALS J, D, AND S OR AN EQUIVALENT LEGENDKEYNOTES SYMBOL DESCRIPTION DETAILSYMBOLDESCRIPTIONDETAIL NOTES 1.LANDING LENGTHS AT ALL EXTERIOR DOOR SHALL BE A MINIMUM OF 36 INCHES IN THE DIRECTION OF TRAVEL. R311.3 2.PROVIDE A MINIMUM OF ONE CONTINUOUS HANDRAIL ON STAIRWAYS WITH 4 OR MORE RISERS AND AT ALL OPEN SIDES. 3.HANDRAIL SHOULD BE CONTINUOUS WITHOUT INTERRUPTION BY NEWEL POST OR OTHER OBSTRUCTION, EXCEPT AT THE LANDING, VOLUTE, OR TURNOUT ON LOWEST TREAD. SYMBOL ACCESS CONTROL16 17 ACCESS PANEL FOR FLOOR CLEANOUT DOUBLE SINK WITH GARBAGE DISPOSAL ELECTRICAL TANKLESS WATER HEATER IN CEILING OR IN CABINET UPPER CABINET STORAGE CABINETS ADA VANITY SINK VANITY SINK (E)STAIR ADA LIFT 18HVAC UNIT 19 ALUMINUM / GLASS STOREFRONT EXTERIOR 1 HOUR WALL: INTERIOR PARTITION WALL 20 21 22 23 24 25 26 27 HANDRAIL METAL STUD INTERIOR WALL W/ SOUND INSULATION. PROVIDE ONE LAYER GYP. BD. BOTH SIDES. ADA TOILET FAUCET SOAP DISPENSER MIRROR TOILET PAPER HOLDER TOILET COVER PAPER DISPENSER PAPER TOWEL DISPENSER PLANTER MECH.AIR SUPPLY/RETURN, SEE MECH. DWG'S. 28 29 30 31 32 33 CABINET REPLACE STORAGE DOOR34 INSTANT HOT WATER HEATER35 ROOF ACCESS LADDER & ROOF HATCH36 5 / A7.2 DETAIL 1-4 / A7.1 19,20 / A7.1 1-4 / A7.1 19,20 / A7.1 25,26 / A7.1 25, 26 / A7.1 N TRUE NORTH (N) ACCESSIBLE PARKING (E) PARKING(E) PARKING (E) PARKING(E) PARKING(E) PARKING(E) PARKING 104A 104.1 105A 105.1 106A 106.1 107A 107.1 108A 108.1 109A 109.1 110A 110.1 111A 111.1 124A 124.1 123A 123.1 122A 122.1 121A 121.1 120A 120.1 119A 102.1 102A 125A 114A 115A 125.1 113A 10 1 A 101.1 113.3 113.2 113.1 111.2 126.1 115.1 117.1116.1 117A116A 11 11 1 TYP. METER 810 12 13 14 12 13 16 34 119.2 RE-STRIPING 118A 35 35 118B FURNITURE SCHEDULE SYM.DIMENSION (WxDxH) T-1 TYPE T-3 T-2 T-1 T-1 T-1 T-1 T-1 T-1 T-1T-1T-1T-1T-1T-1 T-4 T-2T-2 T-2 T-3 T-2 OFFICE TABLE T-4 OFFICE TABLE OFFICE TABLE CONFERENCE TABLE 4'-6" X 2'-5" X 28" 6'-0" X 2'-5" X 28" 6'-0" X 2'-0" X 28" 6'-8" X 4'-2" X 28" NOTE 54"X60" 48"X48" 54"X60" 48"X48" 54"X60" 48"X48" 54"X60" 48 " X 4 8 " AREA DRAIN SEE PLUMBING DWG, 1% SLOPE MAX. TO DRAIN. BLACKOUT FILM 4 OFFICE TABLES TO COMPLY WITH CLEAR FLOOR SPACE AND KNEE & TOE CLEARANCES; SEE DETAIL 11/A0.5b (E) STORAGE M01 (E) STORAGE M02 (E) UTILITY M03 5'-7"8'-10"13'-9" 42'-2"28'-2" DNDN DN DN DN (E) UTILITY M03 20 ' - 5 " 4' - 5 1 / 2 " 11 ' - 1 0 " 10 ' - 9 1 / 2 " 1'- 0 " 49 ' - 2 " 8" S3 A4.2 S1 A4.2 S2 A4.2 S4 A4.2 S8 A4.1 2 A4.1 S7 A4.3 S6 A4.3 S5 A4.3 S7 A4.3 A2.2 MEZZ. FLOOR PLAN AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 SCALE: 1/4" = 1'-0" (E) MEZZ. FLOOR PLAN 1 ELECTRICAL PANEL 200 AMPS. KEEP 3 FEET CLEAR FROM FACE OF ELECTRICAL PANEL TO ANY WALL SURFACE OR OBSTRUCTION TV WALL TOILET GRAB BAR UNDER COUNTER REFRIGERATOR SYMBOL DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 DETAIL 13 14 15 DISHWAHSER COAT HOOKS COUNTERTOP DESCRIPTIONSYMBOLTYPE (E)WALL W1 W2 W3 GLASS PARTITION WALL(FULL HEIGHT) NOTE: THE CODE REQUIRES THAT EQUIPMENT AND DUCT SIZING BE DONE ACCORDING TO ACCA MANUALS J, D, AND S OR AN EQUIVALENT LEGENDKEYNOTES SYMBOL DESCRIPTION DETAILSYMBOLDESCRIPTIONDETAIL NOTES 1.LANDING LENGTHS AT ALL EXTERIOR DOOR SHALL BE A MINIMUM OF 36 INCHES IN THE DIRECTION OF TRAVEL. R311.3 2.PROVIDE A MINIMUM OF ONE CONTINUOUS HANDRAIL ON STAIRWAYS WITH 4 OR MORE RISERS AND AT ALL OPEN SIDES. 3.HANDRAIL SHOULD BE CONTINUOUS WITHOUT INTERRUPTION BY NEWEL POST OR OTHER OBSTRUCTION, EXCEPT AT THE LANDING, VOLUTE, OR TURNOUT ON LOWEST TREAD. SYMBOL ACCESS CONTROL16 17 ACCESS PANEL FOR FLOOR CLEANOUT DOUBLE SINK WITH GARBAGE DISPOSAL ELECTRICAL TANKLESS WATER HEATER IN CEILING OR IN CABINET UPPER CABINET STORAGE CABINETS ADA VANITY SINK VANITY SINK (E)STAIR ADA LIFT 18HVAC UNIT 19 ALUMINUM / GLASS STOREFRONT EXTERIOR 1 HOUR WALL: INTERIOR PARTITION WALL 20 21 22 23 24 25 26 27 HANDRAIL METAL STUD INTERIOR WALL W/ SOUND INSULATION. PROVIDE ONE LAYER GYP. BD. BOTH SIDES. ADA TOILET FAUCET SOAP DISPENSER MIRROR TOILET PAPER HOLDER TOILET COVER PAPER DISPENSER PAPER TOWEL DISPENSER PLANTER MECH.AIR SUPPLY/RETURN, SEE MECH. DWG'S. 28 29 30 31 32 33 CABINET REPLACE STORAGE DOOR34 INSTANT HOT WATER HEATER35 ROOF ACCESS LADDER & ROOF HATCH36 5 / A7.2 SYMBOL DESCRIPTION DETAILSYMBOL ROOF GUARDRAIL37 10 / A7.2 DETAIL 1-4 / A7.1 19,20 / A7.1 1-4 / A7.1 19,20 / A7.1 25,26 / A7.1 25, 26 / A7.1 5 SEE ELEC. DWGS 36 70'-4" 70'-4" 70'-4" 49 ' - 2 " 49'-2 31/32" 119'-6 31/32" 50 ' - 0 " 50 ' - 0 " 49'-2 31/32" 119'-6 31/32" 5'-0" 22 ' - 3 1 / 2 " 5" 5" S3 A4.2 S1 A4.2 S2 A4.2 S4 A4.2 S8 A4.1 1 A4.1 2 A4.1 S7 A4.3 S6 A4.3 S5 A4.3 S7 A4.3 1'-8"3'-5" 30" MIN. CLR 2'-6" 2' - 6 " 2'- 6 " 2'-6" 1'-8"3'-5" 30" MIN. CLR 4'-7" 2'-7" 11 ' - 9 " A2.3 FLOOR PLAN: ROOF PLAN AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 SCALE: 1/4" = 1'-0" FLOOR PLAN: ROOF 1 ELECTRICAL PANEL 200 AMPS. KEEP 3 FEET CLEAR FROM FACE OF ELECTRICAL PANEL TO ANY WALL SURFACE OR OBSTRUCTION TV WALL TOILET GRAB BAR UNDER COUNTER REFRIGERATOR SYMBOL DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 DETAIL 13 14 15 DISHWAHSER COAT HOOKS COUNTERTOP DESCRIPTIONSYMBOLTYPE (E)WALL W1 W2 W3 GLASS PARTITION WALL(FULL HEIGHT) NOTE: THE CODE REQUIRES THAT EQUIPMENT AND DUCT SIZING BE DONE ACCORDING TO ACCA MANUALS J, D, AND S OR AN EQUIVALENT LEGENDKEYNOTES SYMBOL DESCRIPTION DETAILSYMBOLDESCRIPTIONDETAIL NOTES 1.LANDING LENGTHS AT ALL EXTERIOR DOOR SHALL BE A MINIMUM OF 36 INCHES IN THE DIRECTION OF TRAVEL. R311.3 2.PROVIDE A MINIMUM OF ONE CONTINUOUS HANDRAIL ON STAIRWAYS WITH 4 OR MORE RISERS AND AT ALL OPEN SIDES. 3.HANDRAIL SHOULD BE CONTINUOUS WITHOUT INTERRUPTION BY NEWEL POST OR OTHER OBSTRUCTION, EXCEPT AT THE LANDING, VOLUTE, OR TURNOUT ON LOWEST TREAD. SYMBOL ACCESS CONTROL16 17 ACCESS PANEL FOR FLOOR CLEANOUT DOUBLE SINK WITH GARBAGE DISPOSAL ELECTRICAL TANKLESS WATER HEATER IN CEILING OR IN CABINET UPPER CABINET STORAGE CABINETS ADA VANITY SINK VANITY SINK (E)STAIR ADA LIFT 18HVAC UNIT 19 ALUMINUM / GLASS STOREFRONT EXTERIOR 1 HOUR WALL: INTERIOR PARTITION WALL 20 21 22 23 24 25 26 27 HANDRAIL METAL STUD INTERIOR WALL W/ SOUND INSULATION. PROVIDE ONE LAYER GYP. BD. BOTH SIDES. ADA TOILET FAUCET SOAP DISPENSER MIRROR TOILET PAPER HOLDER TOILET COVER PAPER DISPENSER PAPER TOWEL DISPENSER PLANTER MECH.AIR SUPPLY/RETURN, SEE MECH. DWG'S. 28 29 30 31 32 33 CABINET REPLACE STORAGE DOOR34 INSTANT HOT WATER HEATER35 ROOF ACCESS LADDER & ROOF HATCH36 5 / A7.2 SYMBOL DESCRIPTION DETAILSYMBOL ROOF GUARDRAIL37 10 / A7.2 DETAIL 1-4 / A7.1 19,20 / A7.1 1-4 / A7.1 19,20 / A7.1 25,26 / A7.1 25, 26 / A7.1 N TRUE NORTH (E) ROOF (E) SKYLIGHT (N) HVAC (N) HVAC 36 37 37 37 (E)ROOF DRAIN (E)ROOF DRAIN UP UP UP UP UP UP DN F. E . F.E. DN 4'-3" OFFICE 104 LOUNGE 101 MEETING ROOM 102 OFFICE 105 OFFICE 106 OFFICE 107 OFFICE 108 OFFICE 109 OFFICE 110 OFFICE 111 OFFICE 119 OFFICE 120 OFFICE 121 OFFICE 122 OFFICE 123 OFFICE 124 STORAGE 126 OFFICE 125 OFFICE 117 OFFICE 116 HALLWAY 1 103 HALLWAY 2 118 UNISEX 114 UNISEX 115 PRINT 112 ENTRY 113 WH DNDN DN DN DNWH DNDN DN DN DN A2.4 FINISH PLAN: FIRST FLOOR & MEZZ. FLOOR SCALE: 1/4" = 1'-0" FINISH PLAN: FIRST FLOOR 1SCALE: 1/4" = 1'-0" FINISH PLAN: (E) MEZZ. FLOOR 2 CS-1120-125 126 ROOM NAME GROUT DOOR CASING WALL FINISH: NORTH WALL FINISH: EAST WALL FINISH: SOUTH WALL FINISH: WEST NOTES MEETING ROOM N/A HALL WAY 1 OFFICE (TYP.) HALLWAY 2 OFFICE N/A N/A N/A FINISH SCHEDULES CS-1 CS-2 TL-2 CS-1 CS-1 OFFICE N/A CS-1 GL-2 LOUNGE N/A GL-1 GR-1 OFFICE (TYP.)N/A CS-1 N/A ROOM #FLOOR FINISH 101 102 103 104 105-111 112 113 114 115 116-117 118 119 PRINT AREA ENTRY UNISEX RESTROOM SP-1 N/A PT-2 OFFICE (TYP.) STORAGE REPLACE FLOORING UNISEX RESTROOM SP-1 SP-1 SP-1 SP-1 TL-1 TL-1 SP-1 CPT-1 PL-1 PL-1 PL-1 SL-1 PL-1 PL-1 PL-1 GR-1 N/A N/A N/A N/A PT-1 PL-1PL-1 PL-1 PT-1 GL-1 N/A N/A N/A CS-3 CS-3 PL-1 GL-1 PT-2 PT-2 N/A PT-2 PT-2 PL-1 PL-1 PT-3TL-2 PT-3 TL-2 PT-3TL-1 PT-3 TL-2 PT-3 TL-2 PT-3 TL-2 PT-3TL-1 PT-3 PT-1 PT-1 GL-1 PL-1 GL-1 PL-1 GL-1 PL-1 N/A PT-2 PL-1 GL-1 N/A PL-1 GL-1 PT-2 PL-1 GL-1 PT-1 PT-2 PL-1 GL-1PT-2 PT-1 PT-1 WD-1 GL-1 PT-2 PT-2 PT-1 PT-2 GL-2 GL-2 PL-1 GL-1 PT-2 PT-2 N/A N/A PT-2 PL-1 GL-1 PT-2 PL-1 GL-1PT-2 KEEP EXISTING RE-PAINTMEZZANINE PT-2 PT-2 PT-2 PT-2CPT-2 N/A KEEP EXISTING RE-PAINT CS-1PL-1 PT-1PT-2 PT-2 PT-2 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 CA-4 CA-2 CA-1 CA-3 MATERIAL SPECIFICATIONS TYPE / MANUFACTURER MODEL / FINISH SIZE#TYPE / MANUFACTURER MODEL / FINISH SIZE NOTE# CPT-1 CARPET / INTERFACE GENERAL NOTES 1.ALL RECESSED LIGHTS TO BE FURNISHED AND INSTALLED BY GC. 2.ALL OTHER LIGHTINGS (EXTERIOR AND INTERIOR LIGHT FIXTURES) TO BE FURNISHED BY OWNER AND INSTALLED BY GC. 3.ALL DOOR AND CABINET HARDWARES TO BE FURNISHED BY OWNER AND INSTALLED BY GC. 4.INTERIOR DRYWALL FINISH: SMOOTH FINISH. 5.SOLID 58" PLYWOOD BOX FOR ALL CABINETS. 6.SELF CLOSING DRAWER SLIDES & HINGES. TL-1 PL-1 FLOORING PT-1 PAINT / DUNN EDWARS PAINT NOTE PT-3 PT-2 ACCENT WALL RESTROOM WALL / CEILING WALL & DOOR CONDITIONS WOODGRAIN LAMINATE / FORMICA OR WILSONART 8844-WR CS-1 CASING CA-1 MILLWORK / CABINETRY CA-2 CABINET / LAMINATE/ FORMICA OR WILSONART PRINT AREA/ CONTRACTOR TO PROVIDE SHOP DWG MATERIAL SPECIFICATIONS TYPE / MANUFACTURER MODEL / FINISH SIZE#TYPE / MANUFACTURER MODEL / FINISH SIZE NOTE#NOTE TILE / STONE TL-1 TILE / ARIZONA TILE RESTROOM FLOOR / WALL CS-2 OPEN AIR 414 / SHELL 50CM*50CM DET627 / EGG SHELL PAINT / DUNN EDWARS PAINT / DUNN EDWARS DET648 / EGG SHELL GL-1 TEMPERED GLASS / BY ARCADIA INC. GL-2 WOODGRAIN LAMINATE / FORMICA OR WILSONART FRAME ALSO SEE DR/WIN SCHEDULES.PER PLAN ALSO SEE DR/WIN SCHEDULES.PER PLAN FRAMELESS WOODGRAIN LAMINATE / FORMICA OR WILSONART 8844-WR PAINTED MATCH DOOR FRAME ALSO SEE DR/WIN SCHEDULES.PER PLAN CS-3 WOODGRAIN LAMINATE / FORMICA OR WILSONART 8844-WR ALSO SEE DR/WIN SCHEDULES.PER PLAN PIETRA ITALIA WHITE TL-2 TILE / FIRECLAY TILE RESTROOM WALL CHATEAU / SATIN W/ ENGOBE SL-1 EXTERIOR METAL DOOR WITH WOODGRAIN TEXTURE TBD CONTRACTOR TO PROVIDE SAMPLE TBD CT-1 COUTERTOP / COVERINGS ETC LOUNGEMESTRE CREAM VIF CT-2 COUNTERTOP / STARON RESTROOMTERRAZZON BOLOGNA (NT970)VIF LOUNGE / CONTRACTOR TO PROVIDE SHOP DWG PER PLAN / ELEV CABINET / LAMINATE/ FORMICA OR WILSONART WHITE 949 / TBD PER PLAN / ELEV CA-3 RESTROOM/ CONTRACTOR TO PROVIDE SHOP DWG CABINET / LAMINATE/ FORMICA OR WILSONART WHITE 949 / TBD PER PLAN / ELEV CA-4 RESTROOM/ CONTRACTOR TO PROVIDE SHOP DWG FLOATING SHELF / LAMINATE/ FORMICA PER PLAN / ELEV8844-WR TRIM ST-1 TILE TRIM / FIRECLAY TILE CHATEAU / SATIN W/ ENGOBE CONTRACTOR TO PROVIDE SAMPLE AL-1 ALUMINUM TRIM / FIRECLAY TILE CONTRACTOR TO PROVIDE SAMPLE BASEBOARD BB-1 BASEBOARD / BY CONTRACTOR S4S MDF/ PAINTED CONTRACTOR TO PROVIDE SAMPLE PL-2 LAMINATE / FORMICA OR WILSONART 8844-WR WHITE 949 / TBD GR-1 GROUT / BY CONTRACTOR GROUT CONTRACTOR TO PROVIDE SAMPLE MISC. PER ELEV FM-1 FROSTED GLASS FILM CONTRACTOR TO PROVIDE SAMPLE PER ELEV / A5.1 MR-1 MIRROR / BY CONTRACTOR PER ELEV MR-2 MAKEUP MIRROR / BY CONTRACTOR PER ELEV CPT-2 CARPET / INTERFACE CONTRACTOR TO PROVIDE SAMPLE CONTRACTOR TO PROVIDE SAMPLE CONTRACTOR TO PROVIDE SAMPLETBDTBD TL-1 TL-2CONTRACTOR TO PROVIDE SAMPLE CONTRACTOR TO PROVIDE SAMPLETILE / FIRECLAY TILE24X48 PER ELEV. SP-1 SPC / WOOD CHIC FLOOR 7.17"X60"CLEANSCAPES / FRENCH OAK CONTRACTOR TO PROVIDE SAMPLE TILE / ARIZONA TILE PIETRA ITALIA WHITE 24X48 PER ELEV. TILE / ARIZONA TILE PIETRA ITALIA WHITE 24X48 PER ELEV. CHATEAU / SATIN W/ ENGOBE 2"X6" PER ELEV. 2"X6" PER ELEV. SP-1 BB-1 BB-1 BB-1 BB-1BB-1BB-1BB-1BB-1BB-1BB-1BB-1 BB-1BB-1BB-1BB-1BB-1BB-1BB-1 SP-1 BB-1 SP-1 BB-1 SP-1 BB-1 SP-1 SP-1 BB-1 CPT-1 CPT-1 CPT-1 CPT-1 CPT-1 CPT-1 CPT-1 CPT-1 CPT-1 CPT-1 CPT-1CPT-1CPT-1CPT-1CPT-1CPT-1CPT-1CPT-1 CPT-1 CPT-1 CPT-1 TL-1 TL-1 F. E . F.E. 4'-3" LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1LT-1LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-6 LT-1 LT-1 LT-2LT-2LT-2LT-2LT-2LT-2LT-2LT-2 LT-2LT-2LT-2LT-2LT-2LT-2 LT-2LT-2 LT-3 LT-3 LT-3 LT-3 LT-3 LT-9 LT-5 LT-6 LT-7 LT-8 LT-4 LT-12 LT-1 LT-1 LT-1 LT-5 LT-5 LT-13 UCL UCL LT-13 LT-12 LT-1 LT-1LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-11 LT-10 LT-12 OPEN 7'-6"7'-6"7'-6"7'-6"7'-3"3'-6" EQ EQ EQ 2'-1"EQ EQ EQ EQEQEQ EQ EQ EQ EQ EQ EQ 3'-3"2'-1" 4' - 0 " 4' - 0 " 2' - 0 " 2' - 0 " 16'-9"7'-0" 3'- 8 " 3'- 8 " 1' - 1 0 " 1' - 1 0 " 3' - 7 " 3' - 7 " 1' - 1 1 " 3' - 1 0 " 1' - 1 1 " 1'-6" 2'-6"2'-6"4'-1"3'-7" 3' - 9 " 3'- 9 " 1' - 1 0 1 / 2 " 1' - 1 0 1 / 2 " 3'-11"3'-11"3'-11"3'-5"4'-6"8'-0" 3'- 8 " 1' - 6 " 4'- 3 " 1' - 6 " 4' - 2 " 2' - 1 " 4' - 2 " 2'- 1 " 8' - 4 " 8'-0" 8'-0" 7'-6"7'-6"7'-6"7'-6"7'-6"5'-2"2'-4" 6" 9'- 0 " 4' - 0 " 3'-0" 1'-10"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"8'-4"6'-0" 1' - 1 0 " 3' - 7 " 1' - 9 " 4' - 5 1 / 2 " 3'- 1 1 " 1' - 5 1 / 2 " EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQEQEQ 4' - 6 " 4' - 6 " 8'-8" 7'-6" 7'-4" 6' - 3 " FN-1 FN-1 LT-4 LT-4 LT-4 LT-4 LT-4 LT-4 LT-4 LT-4 LT-4 LT-4 LT-4 LT-4LT-4LT-4LT-4LT-4 LT-4 LT-4 LT-4 LT-4 LT-4 LT-4 LT-4 A3.1 REFLECTED CEILING PLAN: FIRST FLOOR AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 SCALE: 1/4" = 1'-0" REFLECTED CEILING PLAN: FIRST FLOOR 1 F.A.U. IN ATTIC SPACE SYMBOL DESCRIPTION 1 2 3 4 5 6 DETAIL KEYNOTES ELECTRICAL PANEL 400 AMPS. KEEP 3 FEET CLEAR FROM FACE OF ELECTRICAL PANEL TO ANY WALL SURFACE OR OBSTRUCTION ELECTRICAL METER HVAC UNIT 30" X 30" ATTIC ACCESS WITH 30" MIN. HEADROOM LIGHTING WITH VACANCY SENSOR THREE-WAY SWITCH SINGLE-POLE SWITCH LED UNDER CABINET LIGHTING CONTINUOUS ROW FLUORESCENT FIXTURE DOOR BELL COMPUTER DATA OUTLET TELEPHONE OUTLET TELEVISION / CABLE OUTLET HIGH EFFICACY LIGHTING CEILING MOUNTED HIGH EFFICACY LIGHTING WALL MOUNTED HOSE BIBBHBTV S3 S HIGH EFFICACY PENDANT LIGHT CEILING MOUNTEDP EXHAUST FAN W/ HUMIDITY SENSOR W/MIN. 50 CFM DIMMER SWITCHSD HIGH EFFICACY WALL MOUNTED LIGHT C.W. H.W. GAS KEY WHOLE HOUSE FAN COLD WATER OUTLET HOT WATER OUTLET FUEL GAS OUTLET FUEL GAS KEY THERMOSTAT HIGH EFFICACY 4" CEILING RECESSED LIGHTING SMOKE DETECTOR CEILING FAN DUPLEX RECEPTACLE OUTLET W/GROUND-FAULT CIRCUIT-INTERRUPTER. 18" A.F.F. OR AS NOTED. DUPLEX RECEPTACLE OUTLET. W/ ARC FAULT CIRCUIT INTERRUPTER. 18" A.F.F. OR AS NOTED. (AT CEILING)CEILING MOUNTED JUNCTION BOX T SD J AFCICARBON MONOXIDE DETECTOR CM HIGH EFFICACY LIGHTING CEILING RECESSED MOISTURE PROTECTED MP LEGEND SURFACE-MOUNTED LED FIXTURE THREE WAY DIMMER SWITCHSD3 LIGHT WITH HIGH EFFICACYH WALL LIGHT AFCI CLG. FOUR-WAY SWITCHS4 DUPLEX RECEPTACLE OUTLET W/ 2-USB PORTS. W/ ARC FAULT CIRCUIT INTERRUPTER USB UCL GFCI USB OCCUPANCY SENSOR SWITCHSoc JUNCTION BOX, FLUSH IN WALL, 18" A.F.F. OR AS NOTED "HALF-HOT" OUTLET SPLIT-WIRED RECEPTACLE J F 220V FLOOR RECEPTACLE 220 V RECEPTACLESINGLE-POLE SWITCH WITH VACANCY SENSORSV WEATHER PROOF DUPLEX RECEPTACLE OUTLET W/GROUND-FAULT CIRCUIT-INTERRUPTER. 18" A.F.F. OR AS NOTED. AFCI WP DUPLEX RECEPTACLE OUTLET W/ 2-USB PORT. W/GROUND-FAULT CIRCUIT-INTERRUPTER. 18" A.F.F. OR AS NOTED. GFCI RECESSED TROFFER LED FIXTUREEMERGENCY LIGHT NOTE: 1.THE CODE REQUIRES THAT EQUIPMENT AND DUCT SIZING BE DONE ACCORDING TO ACCA MANUALS J, D, AND S OR AN EQUIVALENT 2.ALL OUTLETS SHALL BE AFCI PROTECTED 3.ALL OUTLETS IN BATHROOM AND KITCHEN SHALL BE GFCI PROTECTED 4.LOCAL ELECTRIC COMPANY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION 5.FIELD INSPECTOR TO REVIEW AND APPROVE UNDERGROUND SERVICE REQUIREMENT PRIOR TO CONCRETE PLACEMENT 6.SERVICE EQUIPMENT TO BE GROUNDED PER CURRENT C.E.C. SPECIFICATIONS: 1.USE LUTRON FOR THE FOLLOWING ITEMS: A.LED RECESSED LIGHTING B.LED LINEAR LIGHTING C.SHADING SYSTEMS D.WHOLE HOME SYSTEMS E.DIMMERS AND SWITCHES F.FAN CONTROLS G.TIMERS H.IN-WALL SENSORS I.WALLPLATES AND ACCESSORIES J.VACANCY SENSORS TYPE DESCRIPTION NOTES / REMARKSSYMBOLSPECTYPEDESCRIPTIONNOTES / REMARKS LIGHTING FIXTURE SCHEDULE LED VANITY LIGHT OUTDOOR LINEAR WET RECESSED LED LED WALL SCONE SYMBOL SPEC DWELED PARALLAX LED VANITY LIGHT18", 3500K NODES DOUBLE SCONCE KWL1012BBS LED, T4, 60W 4" RECESS LED DOWN LIGHTSLT-1 MUUTO RIME PENDANT LAMP Ø 9.8",E12 3000K ULTRA THIN LED BUILT-IN UNDER CABINET INVISIBLE LIGHT BAR DC12V, 10W/M, EMITTING COLOR - WHITE, MILKY SILICONE COVER 3000K LT-2 LT-3 LT-4 LT-5 LT-6 LT-7 LT-8 LT-9 LT-10 LT-11 LT-12 LT-13 UCL OUTDOOR LED WALL SCONE COMMERCIAL OUTDOOR LED SIGN LIGHTS LED PENDANT TRACK LIGHT 4" ADJUSTABLE RECESSED LED DOWN LIGHT SATCO # STC676938 H SERIES 2" LED 120V SMALL CYLINDER TRACK HEAD WHITE - 24° 3000K RAYON 4" LED COMMERCIAL DOWNLIGHT #RVC4 - 50° 4000K RAYON #PRIME 4" LED ARCHITECTURAL ROUND FLANGED ACCENT TRIM ADJUSTABLE - 30° 4000K 4" ADJUSTABLE RECESSED LED DOWN LIGHT RAYON 4" LED COMMERCIAL DOWNLIGHT #RBC4-FN 3500K ELITE #OLS-R-LED-4 4000K 4"X48" ARCHITECTURAL LED RECESSED LINEAR LED PANDANT WEST ELM LINEAR WOOD LED PENDANT Walnut 42" 16W, 3000K, DIMMABLE LED PANDANT HUXE AFFONSA LED OUTDOOR WALL LIGHT 3000K TBD ALCON LIGHTING #12100-8-R-CRxx CONTINUOUS RUN 0.8 INCH 4000K @RESTROOM @RECEPTION LT-14 EXIT SIGN ELITE ELX-618 (FOR DRYWALL CLG) OR ELX-608-G-AL-1-CLEAR CEILING LEGEND 5/8" TYPE 'X' GYPSUM BOARD CEILING WITH SOUND INSULATION, PAINTED COLOR (WHITE). DUNN EDWARDS - DEW380, WHITE EXPOSED CEILING, PAINTED. ACT-1 'ARMSTRONG', CALLA HIGH CAC, 24"x48",SQUARE TEGULAR 9/16, 0.80 NRC / 40 CAC / 170 AC COLOR: WHITE (WH) 24"x48" ACOUSTICAL CEILING PANELS W/ SOUND INSULATION +18'-6" CLG.HT. +8'-0" CLG.HT. +8'-0" CLG.HT. +8'-0" CLG.HT. +8'-0" CLG.HT. +8'-0" CLG.HT. +8'-0" CLG.HT. +8'-0" CLG.HT. +9'-0" CLG.HT. +9'-10" CLG.HT. +9'-10" CLG.HT. +9'-0" CLG.HT. +9'-0" CLG.HT. +9'-0" CLG.HT. +9'-0" CLG.HT. +9'-0" CLG.HT. +8'-0" CLG.HT. +18'-6" CLG.HT. +8'-0" CLG.HT. +18'-6" CLG.HT. +8'-0" CLG.HT. +8'-0" CLG.HT. EXISTING TRUSS WINDOW TREATMENT WINDOW TREATMENT +9'-0" CLG.HT. +9'-0" CLG.HT. +9'-0" CLG.HT. +9'-0" CLG.HT. +9'-0" CLG.HT. +9'-0" CLG.HT. +9'-10" CLG.HT. TYPE DESCRIPTION FIXTURE SCHEDULE SYMBOL SPEC NOTE / REMARKS FN-1 EXHAUST FAN BROAN-NUTONE ROOMSIDE SERIES #AERN80K ACT-1 TYP. ACT-1 TYP. LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-5 LT-5 LT - 5 LT-5 EQ EQ EQ EQ 2' - 1 1 / 2 " 2' - 6 " 3' - 2 1 / 2 " 3' - 2 1 / 2 " 2' - 6 " 4' - 0 " 2' - 1 1 / 2 " 4'-0" EQ EQ EQ EQ EQ A3.2 REFLECTED CEILING PLAN: MEZZ. FLOOR AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 SCALE: 1/4" = 1'-0" REFLECTED CEILING PLAN: MEZZ. FLOOR 1 F.A.U. IN ATTIC SPACE SYMBOL DESCRIPTION 1 2 3 4 5 6 7 8 9 10 DETAIL KEYNOTES ELECTRICAL PANEL 400 AMPS. KEEP 3 FEET CLEAR FROM FACE OF ELECTRICAL PANEL TO ANY WALL SURFACE OR OBSTRUCTION ELECTRICAL METER HVAC UNIT 30" X 30" ATTIC ACCESS WITH 30" MIN. HEADROOM LIGHTING WITH VACANCY SENSOR REMOTE CONTROLLED ROLLER SHADE OUTLET AT EAVE FOR DECORATION LIGHTS F.A.U. W/ ACCESS PANEL LED STRIP LIGHT TOP AND BOTTOM FOR WINE COOLER THREE-WAY SWITCH SINGLE-POLE SWITCH LED UNDER CABINET LIGHTING CONTINUOUS ROW FLUORESCENT FIXTURE DOOR BELL COMPUTER DATA OUTLET TELEPHONE OUTLET TELEVISION / CABLE OUTLET HIGH EFFICACY LIGHTING CEILING MOUNTED HIGH EFFICACY LIGHTING WALL MOUNTED HOSE BIBBHBTV S3 S HIGH EFFICACY PENDANT LIGHT CEILING MOUNTEDP EXHAUST FAN W/ HUMIDITY SENSOR W/MIN. 50 CFM DIMMER SWITCHSD HIGH EFFICACY WALL MOUNTED LIGHT C.W. H.W. GAS KEY WHOLE HOUSE FAN COLD WATER OUTLET HOT WATER OUTLET FUEL GAS OUTLET FUEL GAS KEY THERMOSTAT HIGH EFFICACY 4" CEILING RECESSED LIGHTING SMOKE DETECTOR CEILING FAN DUPLEX RECEPTACLE OUTLET W/GROUND-FAULT CIRCUIT-INTERRUPTER. 18" A.F.F. OR AS NOTED. DUPLEX RECEPTACLE OUTLET. W/ ARC FAULT CIRCUIT INTERRUPTER. 18" A.F.F. OR AS NOTED. (AT CEILING)CEILING MOUNTED JUNCTION BOX T SD J AFCICARBON MONOXIDE DETECTOR CM HIGH EFFICACY LIGHTING CEILING RECESSED MOISTURE PROTECTED MP LEGEND SURFACE-MOUNTED LED FIXTURE THREE WAY DIMMER SWITCHSD3 LIGHT WITH HIGH EFFICACYH WALL LIGHT AFCI CLG. FOUR-WAY SWITCHS4 DUPLEX RECEPTACLE OUTLET W/ 2-USB PORTS. W/ ARC FAULT CIRCUIT INTERRUPTER USB UCL GFCI USB OCCUPANCY SENSOR SWITCHSoc JUNCTION BOX, FLUSH IN WALL, 18" A.F.F. OR AS NOTED "HALF-HOT" OUTLET SPLIT-WIRED RECEPTACLE J F 220V FLOOR RECEPTACLE 220 V RECEPTACLESINGLE-POLE SWITCH WITH VACANCY SENSORSV WEATHER PROOF DUPLEX RECEPTACLE OUTLET W/GROUND-FAULT CIRCUIT-INTERRUPTER. 18" A.F.F. OR AS NOTED. AFCI WP DUPLEX RECEPTACLE OUTLET W/ 2-USB PORT. W/GROUND-FAULT CIRCUIT-INTERRUPTER. 18" A.F.F. OR AS NOTED. GFCI RECESSED TROFFER LED FIXTUREEMERGENCY LIGHT NOTE: 1.THE CODE REQUIRES THAT EQUIPMENT AND DUCT SIZING BE DONE ACCORDING TO ACCA MANUALS J, D, AND S OR AN EQUIVALENT 2.ALL OUTLETS SHALL BE AFCI PROTECTED 3.ALL OUTLETS IN BATHROOM AND KITCHEN SHALL BE GFCI PROTECTED 4.LOCAL ELECTRIC COMPANY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION 5.FIELD INSPECTOR TO REVIEW AND APPROVE UNDERGROUND SERVICE REQUIREMENT PRIOR TO CONCRETE PLACEMENT 6.SERVICE EQUIPMENT TO BE GROUNDED PER CURRENT C.E.C. SPECIFICATIONS: 1.USE LUTRON FOR THE FOLLOWING ITEMS: A.LED RECESSED LIGHTING B.LED LINEAR LIGHTING C.SHADING SYSTEMS D.WHOLE HOME SYSTEMS E.DIMMERS AND SWITCHES F.FAN CONTROLS G.TIMERS H.IN-WALL SENSORS I.WALLPLATES AND ACCESSORIES J.VACANCY SENSORS TYPE DESCRIPTION NOTES / REMARKSSYMBOLSPECTYPEDESCRIPTIONNOTES / REMARKS LIGHTING FIXTURE SCHEDULE LED VANITY LIGHT OUTDOOR LINEAR WET RECESSED LED LED WALL SCONE SYMBOL SPEC DWELED PARALLAX LED VANITY LIGHT18", 3500K NODES DOUBLE SCONCE KWL1012BBS LED, T4, 60W 4" RECESS LED DOWN LIGHTSLT-1 MUUTO RIME PENDANT LAMP Ø 9.8",E12 3000K ULTRA THIN LED BUILT-IN UNDER CABINET INVISIBLE LIGHT BAR DC12V, 10W/M, EMITTING COLOR - WHITE, MILKY SILICONE COVER 3000K LT-2 LT-3 LT-4 LT-5 LT-6 LT-7 LT-8 LT-9 LT-10 LT-11 LT-12 LT-13 UCL OUTDOOR LED WALL SCONE COMMERCIAL OUTDOOR LED SIGN LIGHTS LED PENDANT TRACK LIGHT 4" ADJUSTABLE RECESSED LED DOWN LIGHT SATCO # STC676938 H SERIES 2" LED 120V SMALL CYLINDER TRACK HEAD WHITE - 24° 3000K RAYON 4" LED COMMERCIAL DOWNLIGHT #RVC4 - 50° 4000K RAYON #PRIME 4" LED ARCHITECTURAL ROUND FLANGED ACCENT TRIM ADJUSTABLE - 30° 4000K 4" ADJUSTABLE RECESSED LED DOWN LIGHT RAYON 4" LED COMMERCIAL DOWNLIGHT #RBC4-FN 3500K ELITE #OLS-R-LED-4 4000K 4"X48" ARCHITECTURAL LED RECESSED LINEAR LED PANDANT WEST ELM LINEAR WOOD LED PENDANT Walnut 42" 16W, 3000K, DIMMABLE LED PANDANT HUXE AFFONSA LED OUTDOOR WALL LIGHT 3000K TBD ALCON LIGHTING #12100-8-R-CRxx CONTINUOUS RUN 0.8 INCH 4000K @RESTROOM @RECEPTION LT-14 EXIT SIGN ELITE ELX-618 (FOR DRYWALL CLG) OR ELX-608-G-AL-1-CLEAR CEILING LEGEND 5/8" TYPE 'X' GYPSUM BOARD CEILING WITH SOUND INSULATION, PAINTED COLOR (WHITE). DUNN EDWARDS - DEW380, WHITE EXPOSED CEILING, PAINTED. PR O P E R T Y L I N E PR O P E R T Y L I N E 9' - 4 " 12 ' - 2 " 3" 9'- 1 0 " 2'-10 1/2" 10'-0" 2'-10 1/2"EQ EQ 3"22'-6" 5'-10"3'-10"EQ EQ EQ EQ ±1'-0" 6' - 8 " 2'- 1 0 " 6" 2' - 4 " PR O P E R T Y L I N E PR O P E R T Y L I N E T.O. BUILDING(STREET) +19'-6"(E) 1ST FLOOR FINISH +0'-0" FABRIC AWNING +11'-2' 2'-1 1/2"3'-6"(E)7'-11 1/2"1'-9"(E)12'-9 3/4"2'-6"6'-0"4'-9"1'-9"(E)1'-9"(E)3'-9"(E)3'-0"6'-7 1/2"±1'-4 1/2" 2' - 3 " 6" 4' - 8 " 2' - 1 0 " T.O. BUILDING(REAR) +15'-0"(E) 3'- 0 " TO F I N I S H F L R PROPOSED ADA RAMP (E) ELECTRICAL PANEL, COVER TO BE PAINTED TO MATCH WALL COLOR 15 ' - 0 " 1' - 2 " 16 ' - 2 " 6' - 1 0 " 10 ' - 0 " 2' - 3 " 6' - 1 0 " 6" T.O. PERAPET(STREET) +19'-6"(E) 1ST FLOOR FINISH +0'-0" MEZZ FLOOR FINISH +9'-3"(E) AWNING +11'-2' T.O. PARAPET(STREET) +19'-6"(E) 1ST FLOOR FINISH +0'-0" MEZZ FLOOR FINISH +9'-3"(E) AWNING +11'-2' 8'- 0 " 7'-2"3'-3 1/2"(E)3'-7"(E)12'-6"5'-0"VAR. ±2'-11"11'-0" 1'- 2 " 10 " 1'-0"6" 2'- 0 " 2'- 0 " 9'- 0 " 4" A4.1 BUILDING ELEVATIONS / SECTION AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 SCALE: 1/4" = 1'-0" SOUTH ELEVATION(STREET)1 SCALE: 1/4" = 1'-0" NORTH ELEVATION(REAR)2 5 B 1 A 2 B 6 E 9 B 13 1212 1 A 2 B 3 C 4 D 12 SYMBOL DESCRIPTION DETAIL KEYNOTES EXTERIOR FINISHES 1 2 3 4 5 EXTERIOR COLOR SYMBOL DESCRIPTION DETAIL A XX STOREFRONT ALUMINUM FRAMED DOORS & FIXED WINDOWS B BLACK C D E 6 MAIN STUCCO - SMOOTH FINISH 7 9 FABRIC AWNING 10 11 12 13 ALUMINUM FRAMED FIXED WINDOWS METAL GUARD RAIL STAINLESS STEEL DOOR EXTERIOR LIGHT FIXTURE, SEE ELECTRICAL DWG'S. WALL VENT CAP: SPEEDI-PRODUCTS-J BLOCK VENT HOOD IN BROWN OR EQUAL WEATHERED TIMBER BUILDING ADDRESS LETTERS (SEE SIGN PACKAGE) BUILDING SIGNAGE LETTERS (SEE SIGN PACKAGE) EXPOSED AGGREGATE 14 ADA LIFT 15 (E)SKYLIGHT GREY PROVIDED BY GC WOOD MULTI- NATURAL STONE MULTI - NATURAL WOOD LAMINATED WOOD PATTERN F XX DARK GREY MATERIAL SPECIFICATIONS TYPE / MANUFACTURER MODEL / FINISH SIZE#TYPE / MANUFACTURER MODEL / FINISH SIZE NOTE# CPT-1 CARPET / INTERFACE GENERAL NOTES 1.ALL RECESSED LIGHTS TO BE FURNISHED AND INSTALLED BY GC. 2.ALL OTHER LIGHTINGS (EXTERIOR AND INTERIOR LIGHT FIXTURES) TO BE FURNISHED BY OWNER AND INSTALLED BY GC. 3.ALL DOOR AND CABINET HARDWARES TO BE FURNISHED BY OWNER AND INSTALLED BY GC. 4.INTERIOR DRYWALL FINISH: SMOOTH FINISH. 5.SOLID 58" PLYWOOD BOX FOR ALL CABINETS. 6.SELF CLOSING DRAWER SLIDES & HINGES. TL-1 PL-1 FLOORING PT-1 PAINT / DUNN EDWARS PAINT NOTE PT-3 PT-2 ACCENT WALL RESTROOM WALL / CEILING WALL & DOOR CONDITIONS WOODGRAIN LAMINATE / FORMICA OR WILSONART 8844-WR CS-1 CASING CA-1 MILLWORK / CABINETRY CA-2 CABINET / LAMINATE/ FORMICA OR WILSONART PRINT AREA/ CONTRACTOR TO PROVIDE SHOP DWG MATERIAL SPECIFICATIONS TYPE / MANUFACTURER MODEL / FINISH SIZE#TYPE / MANUFACTURER MODEL / FINISH SIZE NOTE#NOTE TILE / STONE TL-1 TILE / ARIZONA TILE RESTROOM FLOOR / WALL CS-2 OPEN AIR 414 / SHELL 50CM*50CM DET627 / EGG SHELL PAINT / DUNN EDWARS PAINT / DUNN EDWARS DET648 / EGG SHELL GL-1 TEMPERED GLASS / BY ARCADIA INC. GL-2 WOODGRAIN LAMINATE / FORMICA OR WILSONART FRAME ALSO SEE DR/WIN SCHEDULES.PER PLAN ALSO SEE DR/WIN SCHEDULES.PER PLAN FRAMELESS WOODGRAIN LAMINATE / FORMICA OR WILSONART 8844-WR PAINTED MATCH DOOR FRAME ALSO SEE DR/WIN SCHEDULES.PER PLAN CS-3 WOODGRAIN LAMINATE / FORMICA OR WILSONART 8844-WR ALSO SEE DR/WIN SCHEDULES.PER PLAN PIETRA ITALIA WHITE TL-2 TILE / FIRECLAY TILE RESTROOM WALL CHATEAU / SATIN W/ ENGOBE SL-1 EXTERIOR METAL DOOR WITH WOODGRAIN TEXTURE TBD CONTRACTOR TO PROVIDE SAMPLE TBD CT-1 COUTERTOP / COVERINGS ETC LOUNGEMESTRE CREAM VIF CT-2 COUNTERTOP / STARON RESTROOMTERRAZZON BOLOGNA (NT970)VIF LOUNGE / CONTRACTOR TO PROVIDE SHOP DWG PER PLAN / ELEV CABINET / LAMINATE/ FORMICA OR WILSONART WHITE 949 / TBD PER PLAN / ELEV CA-3 RESTROOM/ CONTRACTOR TO PROVIDE SHOP DWG CABINET / LAMINATE/ FORMICA OR WILSONART WHITE 949 / TBD PER PLAN / ELEV CA-4 RESTROOM/ CONTRACTOR TO PROVIDE SHOP DWG FLOATING SHELF / LAMINATE/ FORMICA PER PLAN / ELEV8844-WR TRIM ST-1 TILE TRIM / FIRECLAY TILE CHATEAU / SATIN W/ ENGOBE CONTRACTOR TO PROVIDE SAMPLE AL-1 ALUMINUM TRIM / FIRECLAY TILE CONTRACTOR TO PROVIDE SAMPLE BASEBOARD BB-1 BASEBOARD / BY CONTRACTOR S4S MDF/ PAINTED CONTRACTOR TO PROVIDE SAMPLE PL-2 LAMINATE / FORMICA OR WILSONART 8844-WR WHITE 949 / TBD GR-1 GROUT / BY CONTRACTOR GROUT CONTRACTOR TO PROVIDE SAMPLE MISC. PER ELEV FM-1 FROSTED GLASS FILM CONTRACTOR TO PROVIDE SAMPLE PER ELEV / A5.1 MR-1 MIRROR / BY CONTRACTOR PER ELEV MR-2 MAKEUP MIRROR / BY CONTRACTOR PER ELEV CPT-2 CARPET / INTERFACE CONTRACTOR TO PROVIDE SAMPLE CONTRACTOR TO PROVIDE SAMPLE CONTRACTOR TO PROVIDE SAMPLETBDTBD TL-1 TL-2CONTRACTOR TO PROVIDE SAMPLE CONTRACTOR TO PROVIDE SAMPLETILE / FIRECLAY TILE24X48 PER ELEV. SP-1 SPC / WOOD CHIC FLOOR 7.17"X60"CLEANSCAPES / FRENCH OAK CONTRACTOR TO PROVIDE SAMPLE TILE / ARIZONA TILE PIETRA ITALIA WHITE 24X48 PER ELEV. TILE / ARIZONA TILE PIETRA ITALIA WHITE 24X48 PER ELEV. CHATEAU / SATIN W/ ENGOBE 2"X6" PER ELEV. 2"X6" PER ELEV. SCALE: 1/4" = 1'-0" SECTION S8 PT-1 BB-1 PL-1 PT-1PT-1PT-1 BB-1BB-1 PT-2 SOUND INSULATION AT WALL AND CEILING, TYP. 19-20 A-7.1 TYP. 5/A7.1 9'- 0 " T.O. PARAPET(STREET) +19'-6"(E) 1ST FLOOR FINISH +0'-0" MEZZ FLOOR FINISH +9'-3"(E) AWNING +11'-2' T.O. BUILDING(REAR) +19'-6"(E) 1ST FLOOR FINISH +0'-0" MEZZ FLOOR FINISH +9'-3"(E) FABRIC AWNING +11'-2' 11 ' - 4 " 5'-0" 14 ' - 4 " 9'- 8 " 12 ' - 2 " 6 1 / 2 " 3'-0" 5 7'-10" 66'-2" 7'-10"7'-10"7'-10"7'-10"7'-10"7'-10"7'-10" 4" 10 ' - 0 " 1'- 2 " 10 " 8'- 0 " 5'-0" 14 ' - 4 " TYP. 6 1/2"TYP. 4'-2" T.O. PARAPET(STREET) +19'-6"(E) 1ST FLOOR FINISH +0'-0" MEZZ FLOOR FINISH +9'-3"(E) AWNING +11'-2' VAR. ±4'-2" 6 1 / 2 " 9'- 8 " 12 ' - 2 " 6 1 / 2 " T.O. BUILDING(REAR) +19'-6"(E) 1ST FLOOR FINISH +0'-0" MEZZ FLOOR FINISH +9'-3"(E) FABRIC AWNING +11'-2' 11 ' - 2 " 2 1/2"TYP. 8 1/2"TYP. 6 1/2"TYP. 2'-10"TYP. 8 1/2"TYP. 6 1/2"TYP. 2'-10"TYP. 8 1/2"TYP. 6 1/2"TYP. 4'-2"TYP. 8 1/2"TYP. 6 1/2"TYP. 4'-2"TYP. 8 1/2"TYP. 6 1/2"TYP. 4'-2"TYP. 8 1/2"TYP. 6 1/2"TYP. 4'-2"TYP. 8 1/2"3'-0" 5 66'-2" 4" T.O. PERAPET(STREET) +19'-6"(E) 1ST FLOOR FINISH +0'-0" MEZZ FLOOR FINISH +9'-3"(E) AWNING +11'-2' T.O. PARAPET(STREET) +19'-6"(E) 1ST FLOOR FINISH +0'-0" MEZZ FLOOR FINISH +9'-3"(E) AWNING +11'-2' 1'- 2 " 10 " 1'-0"6" 2'- 0 " 1'- 2 " 10 " 1'-0"6" 2'- 0 " 12'-0"5'-0"2'-6"11'-0"VAR.16'-0" 9'- 6 " 9'- 6 " 4" T.O. PERAPET(STREET) +19'-6"(E) 1ST FLOOR FINISH +0'-0" MEZZ FLOOR FINISH +9'-3"(E) AWNING +11'-2' T.O. PARAPET(STREET) +19'-6"(E) 1ST FLOOR FINISH +0'-0" MEZZ FLOOR FINISH +9'-3"(E) AWNING +11'-2' 12'-0"5'-0"2'-6"11'-0" 1'- 2 " 10 " 1'-0"6" 2'- 0 " 1'- 2 " 10 " 1'-0"6" 2'- 0 " VAR.16'-0" 9'- 0 " 9'- 0 " 4" A4.2 PROPOSED BUILDING SECTIONS SCALE: 1/4" = 1'-0" SECTION S3 SCALE: 1/4" = 1'-0" SECTION S2 SCALE: 1/4" = 1'-0" SECTION S1 SCALE: 1/4" = 1'-0" SECTION S4 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 101 LOUNGE 104 OFFICE 119 OFFICE 101 LOUNGE 106 OFFICE 121 OFFICE 104 OFFICE 105 OFFICE 106 OFFICE 107 OFFICE 108 OFFICE 109 OFFICE 110 OFFICE 111 OFFICE - STREET - REAR - STREET - REAR PT-2 PT-1PT-1 PL-1PL-1 BB-1 BB-1 PL-1PT-2 PT-1PT-1 PL-1PL-1PL-1 BB-1 BB-1 PT-2PT-2PT-2PT-2PT-2PT-2PT-2PT-2 BB-1 BB-1 BB-1 BB-1 BB-1 BB-1 BB-1BB-1 1 A 5 C 5 C 1 APT-1 PL-1 4 TYP. BY OWNER GL-1 GL-1 AL-1GL-1 GL-1 GL-1 GL-1 GL-1 GL-1 GL-1 PL-1 TYP. SHADOW GAP SYMBOL DESCRIPTION DETAIL KEYNOTES EXTERIOR FINISHES 1 2 3 4 5 EXTERIOR COLOR SYMBOL DESCRIPTION DETAIL A XX STOREFRONT ALUMINUM FRAMED DOORS & FIXED WINDOWS B BLACK C D E 6 MAIN STUCCO - SMOOTH FINISH 7 9 FABRIC AWNING 10 11 12 13 ALUMINUM FRAMED FIXED WINDOWS METAL GUARD RAIL STAINLESS STEEL DOOR EXTERIOR LIGHT FIXTURE, SEE ELECTRICAL DWG'S. WALL VENT CAP: SPEEDI-PRODUCTS-J BLOCK VENT HOOD IN BROWN OR EQUAL WEATHERED TIMBER BUILDING ADDRESS LETTERS (SEE SIGN PACKAGE) BUILDING SIGNAGE LETTERS (SEE SIGN PACKAGE) EXPOSED AGGREGATE 14 ADA LIFT 15 (E)SKYLIGHT GREY PROVIDED BY GC WOOD MULTI- NATURAL STONE MULTI - NATURAL WOOD LAMINATED WOOD PATTERN F XX DARK GREY MATERIAL SPECIFICATIONS TYPE / MANUFACTURER MODEL / FINISH SIZE#TYPE / MANUFACTURER MODEL / FINISH SIZE NOTE# CPT-1 CARPET / INTERFACE GENERAL NOTES 1.ALL RECESSED LIGHTS TO BE FURNISHED AND INSTALLED BY GC. 2.ALL OTHER LIGHTINGS (EXTERIOR AND INTERIOR LIGHT FIXTURES) TO BE FURNISHED BY OWNER AND INSTALLED BY GC. 3.ALL DOOR AND CABINET HARDWARES TO BE FURNISHED BY OWNER AND INSTALLED BY GC. 4.INTERIOR DRYWALL FINISH: SMOOTH FINISH. 5.SOLID 58" PLYWOOD BOX FOR ALL CABINETS. 6.SELF CLOSING DRAWER SLIDES & HINGES. TL-1 PL-1 FLOORING PT-1 PAINT / DUNN EDWARS PAINT NOTE PT-3 PT-2 ACCENT WALL RESTROOM WALL / CEILING WALL & DOOR CONDITIONS WOODGRAIN LAMINATE / FORMICA OR WILSONART 8844-WR CS-1 CASING CA-1 MILLWORK / CABINETRY CA-2 CABINET / LAMINATE/ FORMICA OR WILSONART PRINT AREA/ CONTRACTOR TO PROVIDE SHOP DWG MATERIAL SPECIFICATIONS TYPE / MANUFACTURER MODEL / FINISH SIZE#TYPE / MANUFACTURER MODEL / FINISH SIZE NOTE#NOTE TILE / STONE TL-1 TILE / ARIZONA TILE RESTROOM FLOOR / WALL CS-2 OPEN AIR 414 / SHELL 50CM*50CM DET627 / EGG SHELL PAINT / DUNN EDWARS PAINT / DUNN EDWARS DET648 / EGG SHELL GL-1 TEMPERED GLASS / BY ARCADIA INC. GL-2 WOODGRAIN LAMINATE / FORMICA OR WILSONART FRAME ALSO SEE DR/WIN SCHEDULES.PER PLAN ALSO SEE DR/WIN SCHEDULES.PER PLAN FRAMELESS WOODGRAIN LAMINATE / FORMICA OR WILSONART 8844-WR PAINTED MATCH DOOR FRAME ALSO SEE DR/WIN SCHEDULES.PER PLAN CS-3 WOODGRAIN LAMINATE / FORMICA OR WILSONART 8844-WR ALSO SEE DR/WIN SCHEDULES.PER PLAN PIETRA ITALIA WHITE TL-2 TILE / FIRECLAY TILE RESTROOM WALL CHATEAU / SATIN W/ ENGOBE SL-1 EXTERIOR METAL DOOR WITH WOODGRAIN TEXTURE TBD CONTRACTOR TO PROVIDE SAMPLE TBD CT-1 COUTERTOP / COVERINGS ETC LOUNGEMESTRE CREAM VIF CT-2 COUNTERTOP / STARON RESTROOMTERRAZZON BOLOGNA (NT970)VIF LOUNGE / CONTRACTOR TO PROVIDE SHOP DWG PER PLAN / ELEV CABINET / LAMINATE/ FORMICA OR WILSONART WHITE 949 / TBD PER PLAN / ELEV CA-3 RESTROOM/ CONTRACTOR TO PROVIDE SHOP DWG CABINET / LAMINATE/ FORMICA OR WILSONART WHITE 949 / TBD PER PLAN / ELEV CA-4 RESTROOM/ CONTRACTOR TO PROVIDE SHOP DWG FLOATING SHELF / LAMINATE/ FORMICA PER PLAN / ELEV8844-WR TRIM ST-1 TILE TRIM / FIRECLAY TILE CHATEAU / SATIN W/ ENGOBE CONTRACTOR TO PROVIDE SAMPLE AL-1 ALUMINUM TRIM / FIRECLAY TILE CONTRACTOR TO PROVIDE SAMPLE BASEBOARD BB-1 BASEBOARD / BY CONTRACTOR S4S MDF/ PAINTED CONTRACTOR TO PROVIDE SAMPLE PL-2 LAMINATE / FORMICA OR WILSONART 8844-WR WHITE 949 / TBD GR-1 GROUT / BY CONTRACTOR GROUT CONTRACTOR TO PROVIDE SAMPLE MISC. PER ELEV FM-1 FROSTED GLASS FILM CONTRACTOR TO PROVIDE SAMPLE PER ELEV / A5.1 MR-1 MIRROR / BY CONTRACTOR PER ELEV MR-2 MAKEUP MIRROR / BY CONTRACTOR PER ELEV CPT-2 CARPET / INTERFACE CONTRACTOR TO PROVIDE SAMPLE CONTRACTOR TO PROVIDE SAMPLE CONTRACTOR TO PROVIDE SAMPLETBDTBD TL-1 TL-2CONTRACTOR TO PROVIDE SAMPLE CONTRACTOR TO PROVIDE SAMPLETILE / FIRECLAY TILE24X48 PER ELEV. SP-1 SPC / WOOD CHIC FLOOR 7.17"X60"CLEANSCAPES / FRENCH OAK CONTRACTOR TO PROVIDE SAMPLE TILE / ARIZONA TILE PIETRA ITALIA WHITE 24X48 PER ELEV. TILE / ARIZONA TILE PIETRA ITALIA WHITE 24X48 PER ELEV. CHATEAU / SATIN W/ ENGOBE 2"X6" PER ELEV. 2"X6" PER ELEV. CONDENSER UNIT BEHIND CONDENSER UNIT BEHIND SOUND INSULATION AT WALL AND CEILING, TYP. SOUND INSULATION AT WALL AND CEILING, TYP. SOUND INSULATION AT WALL AND CEILING, TYP. SOUND INSULATION AT WALL AND CEILING, TYP. 25-26 A-7.1 TYP. 19-20 A-7.1 TYP. UC BEV REF KITCHEN SINK FAUCETCRUEK-22972 OPEN TO RESTROOM OPEN TO HALLWAY OPEN TO HALLWAY T.O. PERAPET(STREET) +19'-6"(E) 1ST FLOOR FINISH +0'-0" MEZZ FLOOR FINISH +9'-3"(E) AWNING +11'-2' T.O. BUILDING(REAR) +19'-6"(E) 1ST FLOOR FINISH +0'-0" MEZZ FLOOR FINISH +9'-3"(E) FABRIC AWNING +11'-2' 6'-0"6"6" 4'-6" 3'-0"3'-1 1/2" 12'-10 1/2" TYP. 3'-10" TYP. 6 1/2" TYP. 3'-10" TYP. 6 1/2"TYP. 8 1/2"TYP. 8 1/2" 6" 7'-2" EQ EQ EQ EQ EQ EQ 8'- 0 " 5'-0" 3'- 0 " 2'- 1 0 " 2'- 2 " 1'-6"2'-5"EQ EQ EQ EQ 3"1'-8" 10 ' - 0 " 2'- 2 " 2'- 1 0 " 2'- 0 " 10 " 2" EQ EQ EQ EQ EQ EQ EQ EQ 2'- 0 " 10'-4" 5'-0" 4" T.O. PARAPET(STREET) +19'-6"(E) 1ST FLOOR FINISH +0'-0" MEZZ FLOOR FINISH +9'-3"(E) AWNING +11'-2' OPEN TO LOUNGE OPEN TO HALLWAY T.O. BUILDING(REAR) +19'-6"(E) 1ST FLOOR FINISH +0'-0" MEZZ FLOOR FINISH +9'-3"(E) FABRIC AWNING +11'-2' 8'- 0 " 5'-0" 14 ' - 4 " 11 ' - 2 " 9'- 8 " 12 ' - 2 " 6 1 / 2 " 3'-0" 5 5'-0"7'-2"7'-7"7'-7"16'-6"±20'-4" 66'-2" 4" T.O. PERAPET(STREET) +19'-6"(E) 1ST FLOOR FINISH +0'-0" MEZZ FLOOR FINISH +9'-3"(E) AWNING +11'-2' T.O. BUILDING(REAR) +19'-6"(E) 1ST FLOOR FINISH +0'-0" MEZZ FLOOR FINISH +9'-3"(E) FABRIC AWNING +11'-2' TYP. 8 1/2" TYP. 3'-0" TYP. 6 1/2"TYP. 8 1/2" TYP. 3'-0" TYP. 6 1/2"TYP. 8 1/2" TYP. 3'-0" TYP. 6 1/2"TYP. 8 1/2" TYP. 3'-0" TYP. 6 1/2"TYP. 8 1/2" TYP. 3'-0" TYP. 6 1/2" 2'-11"8 1/2"9" 7 1/2"2 1/2" 8'-1"(E)4'-11" 4" A4.3 BUILDING SECTIONS SCALE: 1/4" = 1'-0" SECTION S6 SCALE: 1/4" = 1'-0" SECTION S5 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 SCALE: 1/4" = 1'-0" SECTION S7 112 PRINT 113 HALLWAY 1 101 LOUNGE 114 UNISEX 116 OFFICE 117 OFFICE 102 CONFERENCE 101 LOUNGE 1 A 5 C PT-3 BB-1 BB-1TL-2 GL-1PT-2 PT-2 PL-1 PL-2 CT-1PL-1 PL-1 PL-1GL-1 4 TYP. BY OWNER TYP. SHADOW GAP PT-2PT-1 PT-3 TL-2 PL-1 PL-2 PT-2 PT-2 4 TYP. BY OWNER PL-2 PL-2 PL-1 1 A 5 CPT-1 AL-1 GL-1 GL-1 13 9 C 14 14 SYMBOL DESCRIPTION DETAIL KEYNOTES EXTERIOR FINISHES 1 2 3 4 5 EXTERIOR COLOR SYMBOL DESCRIPTION DETAIL A XX STOREFRONT ALUMINUM FRAMED DOORS & FIXED WINDOWS B BLACK C D E 6 MAIN STUCCO - SMOOTH FINISH 7 9 FABRIC AWNING 10 11 12 13 ALUMINUM FRAMED FIXED WINDOWS METAL GUARD RAIL STAINLESS STEEL DOOR EXTERIOR LIGHT FIXTURE, SEE ELECTRICAL DWG'S. WALL VENT CAP: SPEEDI-PRODUCTS-J BLOCK VENT HOOD IN BROWN OR EQUAL WEATHERED TIMBER BUILDING ADDRESS LETTERS (SEE SIGN PACKAGE) BUILDING SIGNAGE LETTERS (SEE SIGN PACKAGE) EXPOSED AGGREGATE 14 ADA LIFT 15 (E)SKYLIGHT GREY PROVIDED BY GC WOOD MULTI- NATURAL STONE MULTI - NATURAL WOOD LAMINATED WOOD PATTERN F XX DARK GREY MATERIAL SPECIFICATIONS TYPE / MANUFACTURER MODEL / FINISH SIZE#TYPE / MANUFACTURER MODEL / FINISH SIZE NOTE# CPT-1 CARPET / INTERFACE GENERAL NOTES 1.ALL RECESSED LIGHTS TO BE FURNISHED AND INSTALLED BY GC. 2.ALL OTHER LIGHTINGS (EXTERIOR AND INTERIOR LIGHT FIXTURES) TO BE FURNISHED BY OWNER AND INSTALLED BY GC. 3.ALL DOOR AND CABINET HARDWARES TO BE FURNISHED BY OWNER AND INSTALLED BY GC. 4.INTERIOR DRYWALL FINISH: SMOOTH FINISH. 5.SOLID 58" PLYWOOD BOX FOR ALL CABINETS. 6.SELF CLOSING DRAWER SLIDES & HINGES. TL-1 PL-1 FLOORING PT-1 PAINT / DUNN EDWARS PAINT NOTE PT-3 PT-2 ACCENT WALL RESTROOM WALL / CEILING WALL & DOOR CONDITIONS WOODGRAIN LAMINATE / FORMICA OR WILSONART 8844-WR CS-1 CASING CA-1 MILLWORK / CABINETRY CA-2 CABINET / LAMINATE/ FORMICA OR WILSONART PRINT AREA/ CONTRACTOR TO PROVIDE SHOP DWG MATERIAL SPECIFICATIONS TYPE / MANUFACTURER MODEL / FINISH SIZE#TYPE / MANUFACTURER MODEL / FINISH SIZE NOTE#NOTE TILE / STONE TL-1 TILE / ARIZONA TILE RESTROOM FLOOR / WALL CS-2 OPEN AIR 414 / SHELL 50CM*50CM DET627 / EGG SHELL PAINT / DUNN EDWARS PAINT / DUNN EDWARS DET648 / EGG SHELL GL-1 TEMPERED GLASS / BY ARCADIA INC. GL-2 WOODGRAIN LAMINATE / FORMICA OR WILSONART FRAME ALSO SEE DR/WIN SCHEDULES.PER PLAN ALSO SEE DR/WIN SCHEDULES.PER PLAN FRAMELESS WOODGRAIN LAMINATE / FORMICA OR WILSONART 8844-WR PAINTED MATCH DOOR FRAME ALSO SEE DR/WIN SCHEDULES.PER PLAN CS-3 WOODGRAIN LAMINATE / FORMICA OR WILSONART 8844-WR ALSO SEE DR/WIN SCHEDULES.PER PLAN PIETRA ITALIA WHITE TL-2 TILE / FIRECLAY TILE RESTROOM WALL CHATEAU / SATIN W/ ENGOBE SL-1 EXTERIOR METAL DOOR WITH WOODGRAIN TEXTURE TBD CONTRACTOR TO PROVIDE SAMPLE TBD CT-1 COUTERTOP / COVERINGS ETC LOUNGEMESTRE CREAM VIF CT-2 COUNTERTOP / STARON RESTROOMTERRAZZON BOLOGNA (NT970)VIF LOUNGE / CONTRACTOR TO PROVIDE SHOP DWG PER PLAN / ELEV CABINET / LAMINATE/ FORMICA OR WILSONART WHITE 949 / TBD PER PLAN / ELEV CA-3 RESTROOM/ CONTRACTOR TO PROVIDE SHOP DWG CABINET / LAMINATE/ FORMICA OR WILSONART WHITE 949 / TBD PER PLAN / ELEV CA-4 RESTROOM/ CONTRACTOR TO PROVIDE SHOP DWG FLOATING SHELF / LAMINATE/ FORMICA PER PLAN / ELEV8844-WR TRIM ST-1 TILE TRIM / FIRECLAY TILE CHATEAU / SATIN W/ ENGOBE CONTRACTOR TO PROVIDE SAMPLE AL-1 ALUMINUM TRIM / FIRECLAY TILE CONTRACTOR TO PROVIDE SAMPLE BASEBOARD BB-1 BASEBOARD / BY CONTRACTOR S4S MDF/ PAINTED CONTRACTOR TO PROVIDE SAMPLE PL-2 LAMINATE / FORMICA OR WILSONART 8844-WR WHITE 949 / TBD GR-1 GROUT / BY CONTRACTOR GROUT CONTRACTOR TO PROVIDE SAMPLE MISC. PER ELEV FM-1 FROSTED GLASS FILM CONTRACTOR TO PROVIDE SAMPLE PER ELEV / A5.1 MR-1 MIRROR / BY CONTRACTOR PER ELEV MR-2 MAKEUP MIRROR / BY CONTRACTOR PER ELEV CPT-2 CARPET / INTERFACE CONTRACTOR TO PROVIDE SAMPLE CONTRACTOR TO PROVIDE SAMPLE CONTRACTOR TO PROVIDE SAMPLETBDTBD TL-1 TL-2CONTRACTOR TO PROVIDE SAMPLE CONTRACTOR TO PROVIDE SAMPLETILE / FIRECLAY TILE24X48 PER ELEV. SP-1 SPC / WOOD CHIC FLOOR 7.17"X60"CLEANSCAPES / FRENCH OAK CONTRACTOR TO PROVIDE SAMPLE TILE / ARIZONA TILE PIETRA ITALIA WHITE 24X48 PER ELEV. TILE / ARIZONA TILE PIETRA ITALIA WHITE 24X48 PER ELEV. CHATEAU / SATIN W/ ENGOBE 2"X6" PER ELEV. 2"X6" PER ELEV. CONDENSER UNIT BEHIND SOUND INSULATION AT WALL AND CEILING, TYP.1-4 A-7.1 CONTRACTOR PROVIDE SHOW DRAWING 25-26 A-7.1 TYP. 3' - 4 " 2' - 1 0 " 3' - 4 " 8' - 0 " EQ 4" EQ 2'-3"±3" 8' - 0 " 2' - 1 0 " 3' - 4 " 2'-0"1'-0"5" 4'-0"± 3'-9" 8' - 0 " 3' - 4 " 3'- 1 1 " 2' - 5 " 3' - 4 " 3'- 1 1 " 2' - 5 " 2'-0"EQ EQ 8' - 0 " 5' - 0 " 3'-5"± 2'-6" 8' - 0 " 3'- 4 " 3'- 1 1 " 1'-0" 3'-11"±4" 3'- 4 " 40 " M A X . W H E N M O U N T E D OV E R C O U N T E R O R L A V . EQ ± 2'-9" EQ 8' - 0 " 5' - 8 " 4" 7" 4'-5" PLUMBEREX, PRO-EXTREME SERIES X4333 KIT INCLUDES: P-TRAP COVER, TWO (2) SUPPLY COVERS 9" MI N . 27 " MI N . 29 " MI N . 34 " MA X 2'- 9 " ( 3 3 " - 3 6 " ) T. O . G R I P P I N G O F S U R F A C E 8' - 0 " 3'- 4 " 6"2'-0"5" 4'-0"± 3'-3" 34 " M A X . 40 " M A X . W H E N M O U N T E D OV E R C O U N T E R O R L A V . PLUMBEREX, PRO-EXTREME SERIES X4333 KIT INCLUDES: P-TRAP COVER, TWO (2) SUPPLY COVERS 6" MAX.36" MIN. 12" MIN.8' - 0 " 2' - 2 " 3'- 4 " 24" MIN. 48" MIN. CLR. TO ADJ. WALL 7"-9" 48" 54" MIN 42" MIN. 12" MAX. UPUP 7'-2" 7' - 3 " Ø5' - 0 " 1'-0"3'-6"1'-5"1'-3" 1' - 6 " 3' - 5 " ℄ 6" 1' - 0 " 2' - 0 " 2' - 3 " 1' - 6 " 1' - 0 " 1'-3" 9 3 / 4 " ℄ ℄ ℄ ℄ 1'-4"2'-2"℄ 7' - 9 " 5'-0" SCALE:G115 RESTROOM ELEVATION 1/2" = 1'-0" A5.1 RESTROOM ENLARGE PLAN ELEVATION SCALE:H115 RESTROOM ELEVATION 1/2" = 1'-0"SCALE:F115 RESTROOM ELEVATION 1/2" = 1'-0"SCALE:E115 RESTROOM ELEVATION 1/2" = 1'-0" F.F. AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 F.F.F.F.F.F. SCALE:C114 ADA RESTROOM ELEVATION 1/2" = 1'-0"SCALE:D114 ADA RESTROOM ELEVATION 1/2" = 1'-0"SCALE:B114 ADA RESTROOM ELEVATION 1/2" = 1'-0"SCALE:A114 ADA RESTROOM ELEVATION 1/2" = 1'-0" F.F.F.F.F.F.F.F. SCALE:2114 ADA UNISEX RESTROOM FLOOR PLAN 1/2" = 1'-0" SCALE:1115 UNISEX RESTROOM FLOOR PLAN 1/2" = 1'-0" - A5.1 E F G H - A5.1 A B C D 114 UNISEX 114 UNISEX 114 UNISEX 114 UNISEX 1524 25 20 20 17 22 23 18 19115 UNISEX 114 UNISEX 212223 25 20 18 19 16 21 24 26 14 115 UNISEX 115 UNISEX 115 UNISEX 115 UNISEX MAKEUP MIRROR PT-3TL-2 ST-1 TL-1ST-1 PT-3 TL-2ST-1 PT-3 PL-2 PT-3 SS-1 TL-2ST-1 PT-3 PT-3 PT-3 PT-3 TL-2ST-1TL-2ST-1TL-1ST-1CT-1CT-1TL-2ST-1 PL-1 MR-1 MR-1 MR-1 FM-1 MATERIAL SPECIFICATIONS TYPE / MANUFACTURER MODEL / FINISH SIZE#TYPE / MANUFACTURER MODEL / FINISH SIZE NOTE# CPT-1 CARPET / INTERFACE GENERAL NOTES 1.ALL RECESSED LIGHTS TO BE FURNISHED AND INSTALLED BY GC. 2.ALL OTHER LIGHTINGS (EXTERIOR AND INTERIOR LIGHT FIXTURES) TO BE FURNISHED BY OWNER AND INSTALLED BY GC. 3.ALL DOOR AND CABINET HARDWARES TO BE FURNISHED BY OWNER AND INSTALLED BY GC. 4.INTERIOR DRYWALL FINISH: SMOOTH FINISH. 5.SOLID 58" PLYWOOD BOX FOR ALL CABINETS. 6.SELF CLOSING DRAWER SLIDES & HINGES. TL-1 PL-1 FLOORING PT-1 PAINT / DUNN EDWARS PAINT NOTE PT-3 PT-2 ACCENT WALL RESTROOM WALL / CEILING WALL & DOOR CONDITIONS WOODGRAIN LAMINATE / FORMICA OR WILSONART 8844-WR CS-1 CASING CA-1 MILLWORK / CABINETRY CA-2 CABINET / LAMINATE/ FORMICA OR WILSONART PRINT AREA/ CONTRACTOR TO PROVIDE SHOP DWG MATERIAL SPECIFICATIONS TYPE / MANUFACTURER MODEL / FINISH SIZE#TYPE / MANUFACTURER MODEL / FINISH SIZE NOTE#NOTE TILE / STONE TL-1 TILE / ARIZONA TILE RESTROOM FLOOR / WALL CS-2 OPEN AIR 414 / SHELL 50CM*50CM DET627 / EGG SHELL PAINT / DUNN EDWARS PAINT / DUNN EDWARS DET648 / EGG SHELL GL-1 TEMPERED GLASS / BY ARCADIA INC. GL-2 WOODGRAIN LAMINATE / FORMICA OR WILSONART FRAME ALSO SEE DR/WIN SCHEDULES.PER PLAN ALSO SEE DR/WIN SCHEDULES.PER PLAN FRAMELESS WOODGRAIN LAMINATE / FORMICA OR WILSONART 8844-WR PAINTED MATCH DOOR FRAME ALSO SEE DR/WIN SCHEDULES.PER PLAN CS-3 WOODGRAIN LAMINATE / FORMICA OR WILSONART 8844-WR ALSO SEE DR/WIN SCHEDULES.PER PLAN PIETRA ITALIA WHITE TL-2 TILE / FIRECLAY TILE RESTROOM WALL CHATEAU / SATIN W/ ENGOBE SL-1 EXTERIOR METAL DOOR WITH WOODGRAIN TEXTURE TBD CONTRACTOR TO PROVIDE SAMPLE TBD CT-1 COUTERTOP / COVERINGS ETC LOUNGEMESTRE CREAM VIF CT-2 COUNTERTOP / STARON RESTROOMTERRAZZON BOLOGNA (NT970)VIF LOUNGE / CONTRACTOR TO PROVIDE SHOP DWG PER PLAN / ELEV CABINET / LAMINATE/ FORMICA OR WILSONART WHITE 949 / TBD PER PLAN / ELEV CA-3 RESTROOM/ CONTRACTOR TO PROVIDE SHOP DWG CABINET / LAMINATE/ FORMICA OR WILSONART WHITE 949 / TBD PER PLAN / ELEV CA-4 RESTROOM/ CONTRACTOR TO PROVIDE SHOP DWG FLOATING SHELF / LAMINATE/ FORMICA PER PLAN / ELEV8844-WR TRIM ST-1 TILE TRIM / FIRECLAY TILE CHATEAU / SATIN W/ ENGOBE CONTRACTOR TO PROVIDE SAMPLE AL-1 ALUMINUM TRIM / FIRECLAY TILE CONTRACTOR TO PROVIDE SAMPLE BASEBOARD BB-1 BASEBOARD / BY CONTRACTOR S4S MDF/ PAINTED CONTRACTOR TO PROVIDE SAMPLE PL-2 LAMINATE / FORMICA OR WILSONART 8844-WR WHITE 949 / TBD GR-1 GROUT / BY CONTRACTOR GROUT CONTRACTOR TO PROVIDE SAMPLE MISC. PER ELEV FM-1 FROSTED GLASS FILM CONTRACTOR TO PROVIDE SAMPLE PER ELEV / A5.1 MR-1 MIRROR / BY CONTRACTOR PER ELEV MR-2 MAKEUP MIRROR / BY CONTRACTOR PER ELEV CPT-2 CARPET / INTERFACE CONTRACTOR TO PROVIDE SAMPLE CONTRACTOR TO PROVIDE SAMPLE CONTRACTOR TO PROVIDE SAMPLETBDTBD TL-1 TL-2CONTRACTOR TO PROVIDE SAMPLE CONTRACTOR TO PROVIDE SAMPLETILE / FIRECLAY TILE24X48 PER ELEV. SP-1 SPC / WOOD CHIC FLOOR 7.17"X60"CLEANSCAPES / FRENCH OAK CONTRACTOR TO PROVIDE SAMPLE TILE / ARIZONA TILE PIETRA ITALIA WHITE 24X48 PER ELEV. TILE / ARIZONA TILE PIETRA ITALIA WHITE 24X48 PER ELEV. CHATEAU / SATIN W/ ENGOBE 2"X6" PER ELEV. 2"X6" PER ELEV. ELECTRICAL PANEL 200 AMPS. KEEP 3 FEET CLEAR FROM FACE OF ELECTRICAL PANEL TO ANY WALL SURFACE OR OBSTRUCTION TV WALL UNDER COUNTER REFRIGERATOR SYMBOL DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 DISHWAHSER COUNTERTOP ACCESS CONTROL DOUBLE SINK WITH GARBAGE DISPOSAL ELECTRICAL TANKLESS WATER HEATER IN CEILING OR IN CABINET CABINETS ALUMINUM / GLASS STOREFRONT EXTERIOR 1 HOUR WALL: INTERIOR PARTITION WALL 13 14 15 16 UPPER CABINET STORAGE ADA VANITY SINK VANITY SINK ADA TOILET SYMBOL DESCRIPTION COAT HOOKS25 26 CABINET TOILET GRAB BAR 16 17 18 19 20 21 22 23 24 ADA TOILET FAUCET SOAP DISPENSER MIRROR TOILET PAPER HOLDER TOILET COVER PAPER DISPENSER PAPER TOWEL DISPENSER KEYNOTES INSTANT HOT WATER HEATER35 35 35 DOOR TYPE T TEMPERED GLASS IGU, STC 30, TYP. F.F. W H A F.F. H T T T T CB WW H F.F.F.F. W H D E W H F.F.F.F. 8' - 0 " PER SCHEDULE WINDOW TYPE A T T TEMPERED GLASS IGU, STC 30, TYP. B T T 6" 9' - 4 " 9' - 1 0 " , V . I . F . PER SCHEDULE F.F. 7'- 2 " 2' - 3 " V . I . F . (E) PER SCHEDULE (E ) 4 ' - 1 1 " C 8' - 0 " 14 " , V. I . F . PER SCHEDULE 7' - 2 " D EXTERIOR F.F. INTERIOR F.F. 8' - 0 " 6" 6' - 8 " 9' - 5 1 / 2 " PER SCHEDULE A.1 T 8' - 0 " PER SCHEDULE D.1 14 " , V. I . F . A6.0 DOOR / WINDOW SCHEDULES GENERAL NOTES A. EXIT DOOR SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. B. NOT USED. C. ALL REMOVED (DEMOLISHED) DOORS TO BE RE-USED OR RELOCATED WHEN POSSIBLE. SEE PLAN FOR RELOCATION NOTES. STORE ALL DOORS WITH FRAMES, TRIM AND HARDWARE UNTIL COMPLETION OF THE WORK.. D. A EXIT DOOR(S) SHALL BE A MIN. OF 3'-0" X 7'-0" WITH A MINIMUM SWING OF NINETY (90) DEGRESS. WIDTH & HEIGHT OF REQUIRED EXIT DOORWAYS TO COMPLY WITH C.B.C. 1003.3.1 AND 1005.1. E. CONTRACTOR SHALL VERIFY DIMENSIONS OF EXISTING DOOR FRAME UNITS, SCHEDULED FOR NEW DOORS, LOUVRES, PANELS ETC. F. ALL NEW DOOR FRAMES TO BE BY 'TIMELY', FINISH AND COLOR TO MATCH EXISTING WITH SQUARE-EDGED TRIM (NOT TAPERED). G. PAINT ALL FRAMES, UNLESS OTHERWISE NOTED. H.IF THE DOOR HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 INCHES (75MM) FROM THE LATCH, MEASURED TO THE LANDING EDGE OF THE DOOR. J.MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS (38N) FOR EXTERIOR AND INTERIOR DOORS, SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO THE MINIMUM ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS (66.72N), PER SECTION 1133B.2.5 K. NOT USED. L.BRAILLE SYMBOLS: CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE SYMBOLS ARE SPECIFICALLY REQUIRED IN OTHER PORTIONS OF THESE STANDARDS. DOTS SHALL BE 1/10 INCH (2.54 MM) ON CENTERS IN EACH CELL WITH 2/10 INCH (5.08 MM) SPACE BETWEEN CELLS. DOTS SHALL BE RAISED A MINIMUM OF 1/40 INCH (0.635 MM) ABOVE THE BACKGROUND. ALL SIGNS AND IDENTIFICATION SHALL COMPLY WITH TITLE 24, SECTION 1117B.5-1117B.5.10 M.PROVIDE ROOM SIGNS FOR ALL ROOMS. SEE INTERIOR SIGN PROGRAM BY OTHERS. N.PROVIDE PANIC HARDWARE AT (E) EXTERIOR DOOR . SEE A0.6 O.UNDERCUT DOORS ONLY AS REQUIRED PER MECHANICAL PLANS, OR AS OTHERWISE NOTED. DOOR ABBREVIATIONS AL ALUMINUM AN ANODIZED CL CHAIN LINK CS LEAR SEALED CTG CLEAR TEMPERED GLASS (E)EXISTING FF FACTORY FINISH FL FIRELITE GLASS FRP FIBERGLASS REINFORCED POLYESTER GA GALVANIZED HC HOLLOW CORE HF HOLLOW METAL SLIDING FOLDING HM HOLLOW METAL STEEL LG LEADED GLASS (N)NEW NR NON RATED PT PAINT PC POWDER COATED PG PAINT GRADE WOOD PH PANIC HARDWARE PL PLASTIC LAMINATE PO POLISHED PLATE GLASS R REUSE / RELOCATE SC SOLID CORE SG STAIN GRADE WOOD ST STEEL SST STAINLESS STEEL TG TEMPERED GLASS V VINYL WD WOOD WI WROUGHT IRON WG WIRE GLASS NOTE: FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS. Xref .\230601-Camarillo_TB 30X42.dwg DOOR SCHEDULE 3'-0" NU M B E R WIDTH HEIGHTTY P E THICK- NESS 8'-0"1-3/4"A A SIZE MATERIAL FINISH DOOR DOOR FRAME FIRE RATING REMARKS A 1-3/4"12'-6" ROOM NAME OFFICE MEETING ROOM 8'-0"" GENERAL NOTES A.PROVIDE TEMPERED GLAZING PER CBC 2406.4: 1.1.WITHIN 24" OF A DOORWAY AND LESS THAN 60" ABOVE A WALKWAY SHALL BE SAFETY GLAZING. 1.2.WITHIN 60" VERTICALLY AND 36" HORIZONTALLY OF STAIRWAYS AND LANDINGS. 1.3.ALL GLAZING LESS THAN 60" ABOVE A SHOWER OR TUB FLOOR AND WITHIN 60" HORIZONTALLY FROM FIXTURE'S WATER EDGE. B.MAXIMUM REACH FOR WINDOW LOCKS ALLOWED FOR A PARALLEL APPROACH IS 54". C.CONTRACTOR SHALL VERIFY DIMENSIONS OF EXISTING WINDOW FRAME UNITS, SCHEDULED FOR NEW WINDOWS, LOUVRES, PANELS ETC. D.ALL GLAZING (FENESTRATIONS) SHALL BE INSTALLED WITH A CERTIFYING LABEL ATTACHED, SHOWING THE 'U' VALUE AND STC REQUIREMENTS AS STATED IN TITLE 24 ENERGY SHEETS AND ACOUSTICAL REPORTS U.O.N. E.ALL GLAZING TO BE STC-30 PER ACOUSTIC REPORT U.O.N. ABBREVIATIONS AL ALUMINUM AN ANODIZED CL CHAIN LINK CS LEAR SEALED CTG CLEAR TEMPERED GLASS (E)EXISTING FF FACTORY FINISH FL FIRELITE GLASS FRP FIBERGLASS REINFORCED POLYESTER GA GALVANIZED HC HOLLOW CORE HF HOLLOW METAL SLIDING FOLDING HM HOLLOW METAL STEEL LG LEADED GLASS (N)NEW NR NON RATED PT PAINT PC POWDER COATED PG PAINT GRADE WOOD PH PANIC HARDWARE PL PLASTIC LAMINATE PO POLISHED PLATE GLASS R REUSE / RELOCATE SC SOLID CORE SG STAIN GRADE WOOD ST STEEL SST STAINLESS STEEL TG TEMPERED GLASS V VINYL WD WOOD WI WROUGHT IRON WG WIRE GLASS WINDOW SCHEDULE WINDOW NUMBER WIDTH HEIGHTTY P E HEAD HEIGHT DIMENSIONS X 22'-8" REMARK 10'-3" MATERIAL FINISH DESCRIPTION DETAIL SC WD PT AL/CGL SOLID CORE, FLUSH HINGES TO MATCH COLOR OF DOOR PULL HINGES TO MATCH COLOR OF DOOR PULL A A 4'-0" 9'-4" 10'-0" 8'-0" 9'-10" 8'-5" 8'-0" COMMENTS FIXED FIXED FIXED WINDOW FRAME SPECS DETAILS WINDOW MATERIAL WINDOW FINISH FRAME MATERIAL FRAME FINISH STC RATING HARDWARE GROUP HEAD JAMB SILL AL FF STC30 2/A6.0 DOOR FRAME STC RATING STC30 STC30 STC30 STC30 FF 2/A6.0 2/A6.0 2/A6.0 2/A6.0 2/A6.0 1/A6.0 1/A6.0 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 104A 105A 106A 107A 108A 109A 111A 124A 123A 122A 121A 120A 119A 125A 126A 114A 115A 113A 101A 102A 117A 116A 110A ENTRY UNISEX RESTROOM UNISEX RESTROOM STORAGE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE B B A E C A A A A A A A A A A A A A A HINGES TO MATCH COLOR OF DOOR PULL1/A6.0 3'-0"8'-0"1-3/4"SC WD PT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0 3'-0"8'-0"1-3/4"SC PL WD PT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0 3'-0"8'-0"1-3/4"SC WD PT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0 3'-0"8'-0"1-3/4"SC WD PT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0 3'-0"8'-0"1-3/4"SC WD PT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0 3'-0"8'-0"1-3/4"SC WD PT SINGLE CYLINDER DOOR PULL / DEADBOLT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0 3'-0"8'-0"1-3/4"SC WD PT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0 3'-0"8'-0"1-3/4"SC WD PT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0 3'-0"8'-0"1-3/4"SC WD PT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0 3'-0"8'-0"1-3/4"SC WD PT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0 3'-0"8'-0"1-3/4"SC WD PT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0 3'-0"8'-0"1-3/4"SC WD PT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0 3'-0"8'-0"1-3/4"SC WD PT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0 3'-0"8'-0"1-3/4"SC WD PT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0 3'-0"8'-0"1-3/4"SC WD PT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0 3'-0"8'-0"1-3/4"SC WD PT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0 FF AL HM/CGL HM FFFF/PL6-0"8'-0"1-3/4" 3'-0"7'-0"1-3/4" 2'-6"7'-0"1-3/4" 105.1 106.1 107.1 108.1 109.1 110.1 111.1 124.1 123.1 122.1 121.1 120.1 119.1 102.2 102.1 125.1 101.1 119.2 113.3 113.2 113.1 111.2 126.1 115.1 117.1 116.1 104.1 B B C C D OBSCURE GLASS D C A.1 A A A A A A A A A A.1 A A A A A A 10'-0"9'-4"9'-10"FIXED AL FF STC30 2/A6.0 2/A6.0CTG CTG CTG ENTRY D FFFFAL/CGL3'-0"8'-0"1-3/4"AL STC30 SWING CLEAR HIGNES, PH, DR CLOSER, DR STOP, MAGNETIC HOLD OPEN STC30 HINGES TO MATCH COLOR OF DOOR PULL1/A6.0 CTG AL (FRAMELESS)FF D.1 2'-6"8'-0"8'-5"FIXED CTG AL FF STC30 2/A6.0 2/A6.0 3'-6"4'-11"8'-0"FIXED CTG AL FF STC30 2/A6.0 2/A6.0 1'-9"6'-8"8'-0"FIXED CTG AL FF STC30 2/A6.0 2/A6.0 1'-9"6'-8"8'-0"FIXED CTG AL FF STC30 2/A6.0 2/A6.0 1'-9"6'-8"8'-0"FIXED CTG AL FF STC30 2/A6.0 2/A6.0 3'-9"4'-11"8'-0"FIXED CTG AL FF STC30 2/A6.0 2/A6.0 REPLACE (E) WINDOW REPLACE (E) WINDOW AL/ AL (FRAMELESS)FF 1'-0"10'-0"8'-5"FIXED STC30 2/A6.0 2/A6.0CTGALFF 12'-10"8'-0"8'-0"FIXED STC30 2/A6.0 2/A6.0CTGAL (FRAMELESS)FF 8'-0"8'-0"FIXED STC30 2/A6.0 2/A6.0CTGAL (FRAMELESS)FF 8'-0"8'-0"FIXED STC30 2/A6.0 2/A6.0CTGAL (FRAMELESS)FF 8'-0"8'-0"FIXED STC30 2/A6.0 2/A6.0CTGAL (FRAMELESS)FF 8'-0"8'-0"FIXED STC30 2/A6.0 2/A6.0CTGAL (FRAMELESS)FF 8'-0"8'-0"FIXED STC30 2/A6.0 2/A6.0CTGAL (FRAMELESS)FF 8'-0"8'-0"FIXED STC30 2/A6.0 2/A6.0CTGAL (FRAMELESS)FF 8'-0"8'-0"FIXED STC30 2/A6.0 2/A6.0CTGAL (FRAMELESS)FF 3'-10"8'-0"8'-0"FIXED STC30 2/A6.0 2/A6.0CTGAL (FRAMELESS)FF 3'-10"8'-0"8'-0"FIXED STC30 2/A6.0 2/A6.0CTGAL (FRAMELESS)FF 3'-10"8'-0"8'-0"FIXED STC30 2/A6.0 2/A6.0CTGAL (FRAMELESS)FF 3'-10"8'-0"8'-0"FIXED STC30 2/A6.0 2/A6.0CTGAL (FRAMELESS)FF 3'-10"8'-0"8'-0"FIXED STC30 2/A6.0 2/A6.0CTGAL (FRAMELESS)FF 3'-10"8'-0"8'-0"FIXED STC30 2/A6.0 2/A6.0CTGAL (FRAMELESS)FF 3'-10"8'-0"8'-0"FIXED STC30 2/A6.0 2/A6.0CTGAL (FRAMELESS)FF 3'-10"8'-0"8'-0"FIXED STC30 2/A6.0 2/A6.0CTGAL (FRAMELESS)FF PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL SC SC AL AL FF FF STC30 STC30 3 HINGES, PUSH/PULL HDWR, DR CLOSER, DR STOP, S.S. KICK PLATE SWING CLEAR HIGNES, PH, DR CLOSER, DR STOP, MAGNETIC HOLD OPEN 3 HINGES, PUSH/PULL HDWR, DR CLOSER, DR STOP, S.S. KICK PLATE, ADA SIGN 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 1/A6.0 1/A6.0 1/A6.0 HINGES TO MATCH COLOR OF DOOR PULL HINGES TO MATCH COLOR OF DOOR PULL HINGES TO MATCH COLOR OF DOOR PULL 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 3'-4" 3'-4" OFFICE 3'-0"8'-0"1-3/4"SC WD PT STC30PL 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 118A (E)STORAGE @ HALLWAY2 A 1-3/4"SC WD PT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0PL3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP(E)WIDTH (E)HEIGHT 3 HINGES SINGLE CYLINDER DOOR PULL / DEADBOLT/DR STOP 118B STORAGE @ HALLWAY2 A 1-3/4"SC WD PT HINGES TO MATCH COLOR OF DOOR PULLSTC301/A6.0PL2'-4"7'-0" GRAB BAR BRACKET TYPE A3 6" DEEP LEG TRACK 1 1/2" OUTSIDE DIAMETER STAINLESS STEEL GRAB BAR (3) 1/4" - 20 X 1 1/2" FLAT HEAD STAINLESS STEEL SMS INTO BACKING PLATE NOTE: PREDRILL HOLES THRU CERAMIC TILE METAL SPACERS CERAMIC TILE THIN-SET ON WATER RESISTANT GYPSUM BOARD,SEE SCHEDULE FOR TYPES WALL MEMBRANE (SHOWN DASHED) METAL STUD SECTION PLAN 3 #12 MACHINE SCREWS GRAB BAR BRACKET 1 1/2" 3" 33 " A B O V E FI N I S H E D F L O O R 1/ 2 " M A X . 10 " DOOR, SEE SCHEDULE ALUMINUM DOOR JAMB DOOR SWEEP, SEE SPEC'S. EDGE OF CONC. & HARDWARE SCHEDULE FLOOR SLAB THRESHOLD ALUMINUM JOINT FILLER 1/2" PRE-MOULDED EXP. 1 2" MA X . 1 2 GROUT FILL DOOR STOP BEYOND 2% SLOPE 1 4" 11 2" SCALE:11 STOREFRONT DOOR THRESHOLD 3"=1'-0" 412" 13 4" SCALE:12 STOREFRONT DOOR JAMB 3"=1'-0" NOTE: PROVIDE 1" INSULATED DOUBLE GLAZING LEASE EXHIBIT, (SEE SPECS.) OR TITLE TITLE 24 REPORT LOW E GLASS REQUIRED BY TENANT CONSEALED OVERHEAD SCHEDULE DOOR, SEE DOOR JAMB BEYOND HEAD MEMBER BEYOND STOREFRONT SINGLE ACTING DOOR DOOR STOP CONT. WEATHER- STRIPPING GLASS STOPS CLOSER 41 2" 134" 1/4" GLAZING NOTE: PROVIDE 1" INSULATED DOUBLE GLAZING LEASE EXHIBIT, (SEE SPECS.) OR TITLE TITLE 24 REPORT SCALE:13 STOREFRONT DOOR HEAD 3"=1'-0" LOW E GLASS REQUIRED BY TENANT VINYL BACKER ROD 2% MAX., 1% MIN. AWAY CONC. SIDEWALK, SLOPE CONT. SEALANT OVER BE PLUMB & LEVEL. SET SHIM SILL AS REQ'D. TO FINISH FLOOR CONT. CAULKING AT ON CONT. SEALANT FROM BUILDING W/ CLEAR GLAZING STOREFRONT FRAME ANODIZED ALUMINUM 41 2" 134" JOINT FILLER PRE-MOULDED EXP. NOTE: PROVIDE 1" INSULATED GLAZING WHEN REQUIRED BY TENANT LEASE EXHIBIT, (SEE SPECS.) OR TITLE 24 REPORT (SEE MECH. DRAWINGS) INTERIOR 11 2"EDGE OF CONC. SLAB SCALE:1 STOREFRONT SILL 3"=1'-0" W/ FACE OF PLYWD. SHEATHING 1/4" SHIM CONT. SEALANT, TYP. COLOR ALIGN FACE OF STOREFRONT cL J-MOULD SCREED, PAINT LATH O/ BLDG. PAPER O/ PLYWOOD SHEATHING EXT. CEM. PLASTER O/ MTL. GYP. BD. WALL INSULATION, SEE SPECS FRAME W/ 1/4" CLR. GLASS ANODIZED ALUM. STOREFRONT TO MATCH STOREFRONT CONT. J-MOULD & CAULKING EXTERIOR INTERIOR 4 1 / 2 " WHERE OCCURS, SEE STEEL TUBE COLUMN FLOOR PLAN COLUMN OCCURS 3X6 JAMB STUD WHERE T.S. SCALE:2 STOREFRONT JAMB 3"=1'-0" NOTE: PROVIDE 1" INSULATED DOUBLE GLAZING LEASE EXHIBIT, (SEE SPECS.) OR TITLE TITLE 24 REPORT LOW E GLASS REQUIRED BY TENANT EXT. CEM. PLASTER BLD'G. PAPER O/ CONT. SEALANT, TYP. COLOR TO MATCH BEYOND FACE OF PLASTER CONT. CAULKING 1/4" SHIM SCREED-PAINT O/ METAL LATH O/ CONT. J-MOULD PLYWOOD SHEATHING (SEE STRUCTURAL) FURR'G. @ 24" O.C. CONTINUOUS J-MOULD PLYWOOD SHEATHING FRONT WITH FACE OF ALIGN FACE OF STORE- W/ 1/4" GLAZING STOREFRONT FRAME ANODIZED ALUMINUM STOREFRONT 41 2" 134" PLYWOOD SHEATHING HEADER, SEE STRUCTURAL DWGS. GYP. BD. OVER 2x4 FLAT G.I CORNER BEAD CONTINUOUS FIN. FACE OF WALL BEYOND SCALE:3 STOREFRONT HEAD 3"=1'-0" NOTE: PROVIDE 1" INSULATED DOUBLE GLAZING LEASE EXHIBIT, (SEE SPECS.) OR TITLE TITLE 24 REPORT LOW E GLASS REQUIRED BY TENANT H.M. DOOR SHEATHING EXT. CEM. PLASTER GYPSUM BOARD BATT INSULATION METAL FRAME O/ PLYWOOD CONT. SEALANT SE E F L O O R P L A N FO R W A L L T H I C K N E S S 1 15 16 " 1 15 16 " VA R I E S 2" 1/4"1 3/4"5/8" STRIPPING CONT. WEATHER- FRAME ANCHOR & BACKER ROD 1/ 2 " EXTERIOR INTERIOR SEE SCHED. SCALE:7 EXTERIOR DOOR JAMB 3"=1'-0" SEE FLOOR PLAN FOR WALL THICKNESS VARIES 1 3 / 4 " SEE SCHEDULE DOOR, 5/ 8 " 1 7/8"DR . H E I G H T SHEATHING EXT. CEM. PLASTER PAINT TO MATCH CONT. METAL DRIP, DOOR FRAME 1/ 4 " CONT. WEATHER- 2" STRIPPING SEE STRUCTURAL DRAWINGS 1/2" HOLLOW METAL FRAME FOR FRAMING O/ PLYWOOD GYPSUM BOARD AND SPEC'S. CONT. SEALANT FRAME ANCHOR 2" SCALE:6 EXTERIOR DOOR HEAD 3"=1'-0" SCALE:8 EXTERIOR DOOR @ TRANSOM 3"=1'-0" VARIES 1 3 / 4 " SEE SCHEDULE DOOR, 5/ 8 " 1 7/8"DR . H E I G H T TRANSOM PAINT TO MATCH CONT. METAL DRIP, DOOR FRAME 1/ 4 " CONT. WEATHER- 2" STRIPPING HOLLOW METAL FRAME AND SPEC'S. CONT. SEALANT 2" SEE FLOOR PLAN FOR WALL THICKNESS EXT. CEM. PLASTER BLD'G. PAPER O/ CONT. SEALANT, TYP. COLOR TO MATCH BEYOND FACE OF PLASTER CONT. CAULKING 1/4" SHIM SCREED-PAINT O/ METAL LATH O/ CONT. DRIP GYP. BD. CONTINUOUS CORNER BEAD PLYWOOD SHEATHING W/ DBL. CLEAR GLASS STOREFRONT FRAME ANODIZED ALUMINUM STOREFRONT 41 2" 134" 1x CONT. NAILER SCALE:4 STOREFRONT HEAD 3"=1'-0" NOTE: PROVIDE 1" INSULATED DOUBLE GLAZING LEASE EXHIBIT, (SEE SPECS.) OR TITLE TITLE 24 REPORT LOW E GLASS REQUIRED BY TENANT SCALE:30 GRAB BAR ANCHORAGE N.T.S. x1/4" VENT SLOTS IN SEE ROOF PLAN EA. FLANGES @ 1" O.C. 10 4'-0" O.C. METAL STUD SEE ARCH'L FOR FINISH @ 16" O.C. U.N.O. SEE PLAN FOR SIZE CONT. TRCK 1 1/4" TO MATCH METAL CONT. TRACK (GA. WHEN POSSIBLE FLANGES) W/ 1 1/4" (E)CONC. SLAB ON GRADE SLIP TRACK (2 1/2" 16 GA UNPUNCHED HILT. PNEUMATIC SHOT PIN .145 DIA @16"O.C. 1" EMBED ICC-ESR-1663 FLANGE (GA. TO MATCH 9 8 7 STUD GA.) 6 5 4 3 STUD GA.) STAGGER H H STRUCTURE ABV. 1 2 BOTTOM OF BRACING @ SCALE:26 METAL STUD WALL DETAIL N.T.S. 6" BATT INSULATION FOR 2 x 6 WALL 3 12 " FOR 2 x 4 WALL 5/8" TYPE "X" GYPSUM BOARD SCREWED 12" O.C. EACH SIDE METAL FRAMING PER STRUCTURAL PLAN AND FRAMING SCHEDULE SEE TABLE AND ITEM NO. LISTED BELOW FOR MINIMUM REQUIREMENTS SCALE:25 TYPICAL MTL FRAMED WALL DETAIL 1 1/2" = 1'-0" 1 1 / 2 " DOOR, SEE SCHEDULE SEE PLAN FOR PARTITION TYPES VARIES SEE WALL TYPES 2 3/8" 1 1 / 2 " 3/8" SEMI RIGID PVC SHIMS 90 DURO. 1/2"x3/4"x2" @ 1/4 POINTS OF MODULE FIXING BY MASONRY SCREWS OR CARPET GRIPPER 3/8" VA R I E S SE E W A L L T Y P E S 3/ 8 " ALUMINUM FRAME DOOR, SEE SCHEDULE SEE PLAN FOR PARTITION TYPES FOR FRAMING SEE STRUCTURAL PLANS ALUMINUM FRAME ALUMINUM FRAME FLOORING MATERIAL SEE FINISH PLAN ALUMINUM FRAME DOOR TRANSITION AS OCCURS (SEE FINISH SCHEDULE) LINE OF FLOOR MATERIAL TRANSITION, WHERE OCCURS DOOR - SEE SCHEDULE DOOR STOP BEYOND 1 1/2" 1 1 / 2 " ALUMINUM FRAME GLAZING PER MANUF. RECOMMENDATION SEE PLAN FOR PARTITION TYPES SEE PLAN SEE WALL TYPES 3/8" FOR FRAMING SEE STRUCTURAL PLANS SCALE:20 WINDOWHEAD JAMB (AL) 6"=1'-0" SCALE:19 WINDOWHEAD JAMB (AL) 6"=1'-0" SCALE:18 DOOR JAMB (AL) 6"=1'-0" SCALE:17 DOOR HEAD (AL) 6"=1'-0" SCALE:16 TYPICAL INTERIOR DOOR THRESHOLD 6"=1'-0" VARIES SEE WALL TYPES TRANSITION BETWEEN FLOOR FINISHESA 1 THRESHOLD 2 1/ 4 " MA X . LEVEL CHANGES COMPRESSED CARPET 1/4" MAX. BELOW THRESHOLD FIN. FLOOR LEVEL THRESHOLD 1/2" MAX. 1/4" MAX.B C NOTES: 1. 1/2" MAXIMUM TOTAL HEIGHT WITH 1/4" MAXIMUM VERTICAL CHANGE AT EDGE. 2. 1 : 2 SLOPED BEVEL REQUIRED IF LEVEL CHANGE IS OVER 1/4" VERITCAL LEVEL CHANGE. 3. 1/4" MAXIMUM VERTICAL LEVEL CHANGE. 1/2" MAX. PILE HEIGHT SCALE:29 LEVEL CHANGE N.T.S. LAG FRAME INTO WALL, TYP. VERIFY SIZE, PROVIDE BLOCKING IN WALL AS REQ'D., TYP. 5'-0" MAX. VAR I E S OPEN ENDS SEE EXTERIOR ELEVATIONS SQ. TUBULAR STEEL FRAME, PAINTED STANDING SEAM METAL ROOFING FINISHED FACE OF BUILDING LIGHT FIXTURE, WHERE OCCURS VA R I E S AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 A7.1 ARCHITECTURAL DETAILS SCALE:5 FABRIC AWNING 3/4" = 1'-0" SEE DETAIL 2 & 3 THIS SHEET FOR ALL WIRE & STRUT CONNECTIONS TO DECK COMPRESSION POST - METAL RACK 2 1/2" X 18 GA 12 GA HANGER WIRE W/4 TIGHT WRAPS IN 1 1/2" MAIN RUNNER (4) 12 GA BRACE WIRES W/3 TIGHT WRAPS IN 1 CEILING TILE CROSS RUNNERS 2" MAX. 2" MAX. 4 5 O M A X . 7' - 0 " M A X . 45 O MA X . 2" 16 E FIXED SIDE 1" LESSER OF 8" MAX OR 1/4 RUNNER LENGTH HANGER WIRE (3) TIGHT TURNS IN 1/2" GRID MEMBER MAIN OR SECONDARY PERIMETER ANGLE TO MATCH CEILING SYSTEM POP REVIT CEILING TILE #12 SCREWS 1 1/4" LONG @ EACH STUD 16D FREE SIDE 2" 1"HANGER WIRE SLOTTED ANGLE SPACER W/ HORIZ 6d RINGSHANK HEAD TOWARD C.L OF SPAN.(ALT LOCATION W/OUT NAIL,NOTCHING ONLY AT RUNNER) SEE DETAIL 16 FOR TYPICAL NOTES, CALLOUTS & DIMENSIONS 8" MAX.3"8" MAX. 16 B GRID EXPANSION JOINT BACK TO BACK 2" DEEP CHANNELS FINISH TO A CEILING GRID 12 GA HANGER WIRE W/ 3 TIGHT WRAPS IN 1 1/2" MAIN RUNNER CEILING TILE 16 C LIGHT FIXTURE SUPPORT PROVIDE 2 SUPPORT WIRE FOR LIGHTS LESS THAN 56 LBS & 4 FOR LIGHTS MORE THAN 56 LBS LIGHT FIXTURE CEILING SYSTEM HANGER WIRE PROVIDE MAIN RUNNERS AT THE BOUNDARY OF THE CEILING SYSTEM. PROVIDE DIRECT ATTACHMENT FROM THE LIGHT FIXTURE TO THE MAIN RUNNERS CEILING SYSTEM 16 F COMPRESSION POST AND WIRE DETAIL ATTACH CEILING GRID MEMBERS TO NOT MORE THAN (2) ADJACENT WALLS 3'-0"(MIN.) N.T.S. 3" SCALE:5ROOF HATCH 1" = 1'-0" ROOFING HEADER @ ALL SIDES OF OPENING (SEE STRUCT. DWGS.) FOLDING LADDER WITH INSULATED LID, PAINT TO MATCH ADJACENT ROOF HATCH (2'-6" x 3'-0" MIN.) TOP END OF LADDER RAIL TO BE ROUNDED & GROUND SMOOTH 4"x8 1/2"x1/2x3" L BENT STEEL PLATE LADDER SUPPORT BRACKET CONTINUE ROOFING UP INSULATED CURB WOOD SHIM AS REQ'D. FIBER CANT STRIP. PROVIDE WATERPROOFING 5/8" GYP. BD. SAFETY RAILING SYSTEM, WHERE REQUIRED BY CODE. MIN. SAFETY RAILING OPENING: PREVENT THE PASSAGE OF A 21-INCH-DIAMETER SPHERE SECTION A-A 3 2 3 1A 1BA A MAX PIPE OR CONDUIT DIAM IN. (MM)F RATING HR T RATING HR 1 (25)1 OR 2 0+, 1 OR 2 1 (25)3 OR 4 3 OR 4 4 (102)1 OR 2 0 6 (152)3 OR 4 0 12 (305)1 OR 2 0 SYSTEM NO.W-L-1001 JUNE 15, 2005 F RATINGS - 1, 2, 3 AND 4 HR (SEE ITEMS 2 AND 3), T RATINGS - 0, 1, 2, 3, AND 4 HR (SEE ITEM 3) L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT, L RATING AT 400 F - LESS THAN 1 CFM/SQ FT 1. WALL ASSEMBLY - THE 1, 2, 3 OR 4 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAX 2 HR FIRE RATED ASSEMBLIES) OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED 16 IN. (406 MM) OC WITH NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. (92 MM) WIDE BY 1-3/8 IN. (35 MM) DEEP CHANNELS SPACED MAX 24 IN. (610 MM) OC. B. GYPSUM BOARD* - NOM 1/2 OR 5/8 IN. (13 OR 16 MM) THICK, 4 FT. (122 CM) WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING IS 26 IN. (660 MM). 2.THROUGH PENETRANT - ONE METALLIC PIPE, CONDUIT OR TUBING INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR TUBING AND PERIPHERY OF OPENING SHALL BE MIN OF 0 IN. (0 MM) (POINT CONTACT) TO MAX 2 IN. (51 MM). PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED: A. STEEL PIPE - NOM 24 IN. (610 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. B. IRON PIPE - NOM 24 IN. (610 MM) DIAM (OR SMALLER) SERVICE WEIGHT (OR HEAVIER) CAST IRON SOIL PIPE, NOM 12 IN. (305 MM) DIAM (OR SMALLER) OR CLASS 50 (OR HEAVIER) DUCTILE IRON PRESSURE PIPE. C. CONDUIT - NOM 6 IN. (152 MM) DIAM (OR SMALLER) STEEL CONDUIT OR NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING D. COPPER TUBING - NOM 6 IN. (152 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING E. COPPER PIPE - NOM 6 IN. (152 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. F. THROUGH PENETRATING PRODUCT* - FLEXIBLE METAL PIPING - THE FOLLOWING TYPES OF STEEL FLEXIBLE METAL GAS PIPING MAY BE USED: 1. NOM 2 IN. (51 MM) DIAM (OR SMALLER) STEEL FLEXIBLE METAL GAS PIPING. PLASTIC COVERING ON PIPING MAY OR MAY NOT BE REMOVED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. OMEGA FLEX INC 2. NOM 1 IN. (25 MM) DIAM (OR SMALLER) STEEL FLEXIBLE METAL GAS PIPING. PLASTIC COVERING ON PIPING MAY OR MAY NOT BE REMOVED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. TITEFLEX CORP A BUNDY CO 3. NOM 1 IN. (25 MM) DIAM (OR SMALLER) STEEL FLEXIBLE METAL GAS PIPING. PLASTIC COVERING ON PIPING MAY OR MAY NOT BE REMOVED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. WARD MFG INC 3. FILL,VOID OR CAVITY MATERIAL* - CAULK OR SEALANT - MIN 5/8. 1-1/4,1-7/8 AND 2-1/2 IN. (16, 32,48 AND 64 MM) THICKNESS OF CAULK FOR 1, 2, 3 AND 4 HR RATED ASSEMBLIES, RESPECTIVELY, APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. MIN 1/4 IN. (6 MM) DIAM BEAD OF CAULK APPLIED TO GYPSUM BOARD/PENETRANT INTERFACE AT POINT CONTACT LOCATION ON BOTH SIDES OF WALL. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS SHOWN IN THE FOLLOWING TABLE. THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THE PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS TABULATED BELOW: +WHEN COPPER PIPE IS USED, T RATING IS 0 HR. 3M COMPANY - CP 25WB+ CAULK OR FB-3000 WT SEALANT, *BEARING THE UL CLASSIFICATION MARKING SCALE: WALL - NON-INSULATED PIPE 1 1/2" = 1'-0" SCALE: WALL - INSULATED PIPE 1 1/2" = 1'-0" SECTION A-A 4B 3 A 2 4A 2 3 A 4A 4B 1B1A 1. WALL ASSEMBLY - THE 1 OR 2 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300, U400 OR V400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 IN. BY 4 IN. (25 MM BY 102 MM) LUMBER SPACED 16 IN. (406 MM) OC WITH NOM 2 BY 4 IN. LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. (92 MM) WIDE BY 1-3/8 IN. (35 MM) DEEP CHANNELS SPACED MAX 24 IN. (610 MM) OC. B. GYPSUM BOARD* - NOM 5/8 IN. (16 MM) THICK, 4 FT (122 CM) WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING IS 14-1/2 IN (368 MM) FOR WOOD STUD WALLS AND 18 IN. (457 MM) FOR STEEL STUD WALLS. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS 1 HR WHEN INSTALLED IN A 1 HR FIRE RATED WALL AND 2 HR WHEN INSTALLED IN A 2 HR FIRE RATED WALL. 2. THROUGH PENETRANTS - ONE METALLIC PIPE OR TUBING TO BE CENTERED WITHIN THE FIRESTOP SYSTEM. PIPE OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES OR TUBING MAY BE USED: A. STEEL PIPE - NOM 12 IN. (305 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. B. COPPER TUBING - NOM 6 IN. (152 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. C. COPPER PIPE - NOM 6 IN. (152 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. 3. PIPE COVERING* - NOM 1 IN. OR 2 IN. (25 MM OR 51 MM) THICK HOLLOW CYLINDRICAL HEAVY DENSITY GLASS FIBER UNITS JACKETED ON THE OUTSIDE WITH AN ALL SERVICE JACKET. LONGITUDINAL JOINTS SEALED WITH METAL FASTENERS OR FACTORY-APPLIED SELF-SEALING LAP TAPE. TRANSVERSE JOINTS SEALED WITH METAL FASTENERS OR WITH BUTT STRIP TAPE SUPPLIED WITH THE PRODUCT. WHEN NOM 1 IN. (25 MM) THICK PIPE COVERING IS USED, THE ANNULAR SPACE BETWEEN THE PIPE COVERING AND THE CIRCULAR CUTOUT IN THE GYPSUM WALLBOARD LAYERS ON EACH SIDE OF THE WALL SHALL BE MIN 1/4 IN. TO MAX 3/8 IN. (6 MM TO MAX 10 MM). WHEN NOM 2 IN. (51 MM) THICK PIPE COVERING IS USED, THE ANNULAR SPACE BETWEEN THE PIPE COVERING AND THE CIRCULAR CUTOUT IN THE GYPSUM WALLBOARD LAYERS ON EACH SIDE OF THE WALL SHALL BE MIN 1/2 IN. TO MAX 3/4 IN. (13 MM TO MAX 19 MM). SEE PIPE AND EQUIPMENT COVERING - MATERIALS (BRGU) CATEGORY IN BUILDING MATERIALS DIRECTORY FOR NAMES OF MANUFACTURERS. ANY PIPE COVERING MATERIAL MEETING THE ABOVE SPECIFICATIONS AND BEARING THE UL CLASSIFICATION MARKING WITH A FLAME SPREAD INDEX OF 25 OR LESS AND A SMOKE DEVELOPED INDEX OF 50 OR LESS MAY BE USED. THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS 3/4 HR WHEN NOM 1 IN. (25 MM) THICK PIPE COVERING IS USED. THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS 1 HR AND 1-1/2 HR WHEN NOM 2 IN. (51 MM) THICK PIPE COVERING IS USED WITH 1 HR AND 2 HR FIRE RATED WALLS, RESPECTIVELY. 4. FIRESTOP SYSTEM - INSTALLED SYMMETRICALLY ON BOTH SIDES OF WALL ASSEMBLY. THE DETAILS OF THE FIRESTOP SYSTEM SHALL BE AS FOLLOWS: A. FILL,VOID OR CAVITY MATERIALS* - WRAP STRIP - NOM 1/4 IN. (6 MM) THICK INTUMESCENT ELASTOMERIC MATERIAL FACED ON ONE SIDE WITH ALUMINUM FOIL, SUPPLIED IN 2 IN. (51 MM) WIDE STRIPS. NOM 2 IN. (51 MM) WIDE STRIP TIGHTLY WRAPPED AROUND PIPE COVERING (FOIL SIDE OUT) WITH SEAM BUTTED. WRAP STRIP LAYER SECURELY BOUND WITH STEEL WIRE OR ALUMINUM FOIL TAPE AND SLID INTO ANNULAR SPACE APPROX 1-1/4 IN.(32 MM) SUCH THAT APPROX 3/4 IN. (19 MM) OF THE WRAP STRIP WIDTH PROTRUDES FROM THE WALL SURFACE. ONE LAYER OF WRAP STRIP IS REQUIRED WHEN NOM 1 IN. (25 MM) THICK PIPE COVERING IS USED. TWO LAYERS OF WRAP STRIP ARE REQUIRED WHEN NOM 2 IN. (51 MM) THICK PIPE COVERING IS USED. 3M COMPANY - FS-195+ B. FILL,VOID OR CAVITY MATERIALS* - CAULK OR SEALANT - MIN 1/4 IN. (6 MM) DIAM CONTINUOUS BEAD APPLIED TO THE WRAP STRIP/WALL INTERFACE AND TO THE EXPOSED EDGE OF THE WRAP STRIP LAYER APPROX 3/4 IN. (19 MM) FROM THE WALL SURFACE. 3M COMPANY - CP 25WB+, IC 15WB+, FIREDAM 150+ CAULK OR FB-3000 WT SEALANT *BEARING THE UL CLASSIFICATION MARKING SYSTEM NO.W-L-5001 MAY 19, 2005 F RATINGS - 1 AND 2 HR (SEE ITEM 1), T RATINGS - 3/4, 1 AND 1-1/2 HR (SEE ITEM 3) L RATING AT AMBIENT - 2 CFM/SQ FT, L RATING AT 400 F - LESS THAN 1 CFM/SQ FT 2 20 " M A X . O P E N I N G 42 " M I N . 20 " M A X . O P E N I N G 42 " M I N . 48" ON CENTER MAX. 20 " M A X . 20 " M A X . SCALE:10ROOF GUARDRAIL 3/4" = 1'-0" ROOF LINE ROOF LINE GALVANIZED 1-1/2" DIAMETER TUBE STEEL GUARDRAIL MOUNTING BASE PLATE, TYP. SEE STRUCT. PLANS FOR DETAIL. PROVIDE WATERPROOFING. SECTION VIEW NOTE: 1. THE GUARD SHALL BE CONSTRUCTED SO AS TO PREVENT THE PASSAGE OF A SPHERE 21 INCHES IN DIAMETER. 2. PROVIDE WATERPROOFING AT BASE OF THE GUARDRAIL. 3. SEE STRUCTURE PLANS FOR MOUNTING DETAIL. EQ EQ EQ EQ EQ EQ 16G 2'X2' GRID FIRE SPRINKLER HEADS , SPEAKERS, SMOKE DETECTORS,SIGNAL DEVICES, AND ANY OTHER CEILING FIXTURES SHALL BE PRECISELY LOCATED AS FOLLOWS: a ) IN ALIGNMENT WITH AIR DIFFUSERS AND EACH OTHER, AS SHOWN ABOVE . b) CENTERED WITHIN TILE, AS SHOWN ABOVE. FIRE SPRINKLER HEAD,SMOKE DETECTOR OTHER CEILING MOUNTED TYPICAL,UNLESS INDICATED OTHERWISE DIFFUSER LIGHT 6'-0" MAX. EQ EQ EQ EQ 12 " 12'-0" MAX. COMP POST & BRACE WIRE4'-0" MAX @ RATED CLG6" MAX. 6' - 0 " M A X . 4' - 0 " M A X @ RA T E D C L G 12 ' - 0 " M A X . CO M P P O S T & BR A C E W I R E 6" M A X . PERIMETER PER DETAIL 16D & 16E 12 GA HANGER WIRE @ 4' X 4' OC MAIN RUNNERS COMPRESSION STRUT W/BRACE WIRES PER DETAIL 16F THIS SHEET EXPANSION JOINTS @ CORRIDOR INTERSECTIONS PROVIDE PER DETAIL 16B THIS SHEET CROSS RUNNERS LIGHT FIXTURE ATTACHED PER DETAIL 16C THIS SHEET 16 I TYPICAL LAYOUT PLAN GRID CEILING 16 H 2'X4' GRID OR 2' X 5' GRID NOTE: ALL MAIN AND CROSS RUNNERS TO BE HEAVY DUTY MEMBERS SLOT END OF TUBE OR POST TO FIT OVER MAIN RUNNER N E SW CROSS RUNNER TYP. 2" 12 GA . VERT . HANGER WIRE SET CEILING GRID LEVEL PRIOR TO FASTENING TUBE 12 GA. BRACING WIRE WITH MIN. TIGHT TURNS IN 1 1/2" BOTH ENDS OF WIRE. TYPICAL SEE DETAIL 2 FOR ANCHORING TO DECK COMPRESSION STRUT ( SEE DETAIL 16F) OR OPTIONAL EMT TUBING PER SCHEDULE ABOVE MAIN RUNNER 2 #12 S.M.S CONNECTING COMPRESSION STRUT TO T-BAR GRID TYP. 12 GA. VERTICAL HANGER WIRE @ 4'-0" EACH WAY WITH MIN. 3 TIGHT TURNS IN 1 12" BOTH ENDS OF WIRE. SEE DETAIL 2 FOR ANCHORING TO DECK SUSPENDED CEILING NOTES: A SET OF FOUR SPLAY WIRES SHALL BE PROVIDED FOR EACH 96 S.F. OF TRIBUTARY AREA, FIRST SET OF SPLAY WIRES SHALL BEV WITHIN 4"-0" FROM ANY WALL, PROVIDE COMPRESSION STRUT AT EACH SPLAY WIRE LOCATION 16 J 3D VIEW CEILING OPTIONAL ELECTRICAL METALLIC TUBING (EMT) SCHEDULE SIZE (DIAMETER)L (MAX. HEIGHT) 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 4'-0" 5'-2" 6'-6" 8'-6" 9'-10" 12'-0" STRUTS OTHER THAN EMT, MAY REQUIRE ENGINEERING CALCULATIONS,- CONTRACTOR IS RESPONSIBLE TO CONTRACT A LISENCED STRUCTURAL ENGINEER AND SUBMIT CALCULATIONS SCALE: TYPICAL T-BAR CEILING DETAIL 1/4" = 1'-0"1 NOTE: 1.12 GA, (MIN) HANGER VARIES MAY BE USED FOR UP TO AND INCLUDING 4'-0" X 4'-0" GRID SPACING ALONG MAIN RUNNERS. 2.PROVIDE 12 GA, HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSS RUNNERS WITHIN 8" FROM THE SUPPORT OR WITHIN 1/4 OF THE LENGTH OF THE END TEE, WHICHEVER IS LEAST, FOR THE PERIMETER OF HE CEILING AREA, END CONNECTIONS FOR RUNNERS WHICH ARE DESIGNED AND DETAILED TO RESIST THE APPLIED HORIZONTAL FORCES MAY BE USED IN LIEU OF THE 12 GA, HANGER WIRES. 3.PROVIDE TRAPEZE OR OTHER SUPPLEMENTARY SUPPORT MEMBERS AT OBSTRUCTIONS TO MAIN HANGER SPACING, PROVIDE ADDITIONAL HANGERS, STRUTS OR BRACES AS REQUIRED AT ALL CEILING BREAKS,SOFFITS OR DISCONTINUOUS AREAS,HANGER WIRES THAT ARE MORE THAN 1 IN 6 OUT OF PLUMB ARE TO HAVE COUNTER-SLOPING WIRES. 4.CEILING GRID MEMBERS MAY BE ATTACHED TO NOT MORE THAN 2 ADJACENT WALLS. CEILING GRID MEMBERS LEAST 3/4" FREE OF OTHER WALLS. IF WALLS RUN DIAGONALLY TO CEILING GRID SYSTEM RUNNERS, ONE END OF MAIN AND CROSS RUNNERS SHOULD BE FREE AND A MINIMUM OF 3/4" CLEAR OF WALL. 5.AT THE PERIMETER OF THE CEILING AREA WHERE MAIN OR CROSS RUNNERS ARE NOT CONNECTED TO THE ADJACENT WALL, PROVIDE INTERCONNECTION BETWEEN THE RUNNERS AT THE FREE END TO PREVENT LATERAL SPREADING. A METAL STRUT OR A 16GA, WIRE WITH A POSITIVE MECHANICAL CONNECTION TO THE RUNNER MAY BE USED. WHERE THE PERPENDICULAR DISTANCE FROM THE WALL TO THE FIRST PARALLEL RUNNER IS 12" OR LESS, THIS INTERLOCK IS NOT REQUIRED. 6.PROVIDE SETS OF FOUR 12 GA SPLAYED BRACING WIRES ORIENTED 90 DEGREES FROM EACH OTHER. THE SLOPE OF THESE WIRES SHOULD NOT EXCEED 45 DEGREES FROM THE PLANE OF THE CEILING AND SHOULD BE TAUT WITHOUT CAUSING THE CEILING TO LIFT. SPLICES IN BRACING WIRES ARE NOT TO BE PERMITTED. 7.FASTEN HANGER WIRES WITH NOT LESS THAN THREE TIGHT TURNS, FASTEN BRACING WIRES WITH FOUR TIGHT TURNS. MAKE ALL TIGHT TURNS WITHIN A DISTANCE OF 1-1/2" INCHES. HANGER OR BRACING WIRE ANCHORS TO THE STRUCTURE SHOULD BE INSTALLED IN SUCH A MANNER THAT THE DIRECTION OF THE WIRE ALIGNS AS CLOSELY AS POSSIBLE WITH THE DIRECTION OF THE FORCES ACTING ON THE WIRE. 8.SEPERATE ALL CEILING HANGING AND BRACING WIRES AT LEAST 6 INCHES FROM ALL UNBRACED DUCTS, PIPES, CONDUITS, ETC. IT IS ACCEPTABLE TO ATTACH LIGHTWEIGHT ITEMS, SUCH AS SINGLE ELECTRICAL CONDUIT NOT EXCEEDING 3/4" NOMINAL DIAMETER, TO HANGER WIRES USING CONNECTORS ACCEPTABLE TO OSHPD. 9.WHEN DRILLED -IN CONCRETE ANCHORS OR SHOT-IN ANCHORS ARE USED IN REINFORCED CONCRETE FOR HANGER WIRES, 1 OUT OF 10 MUST BE FIELD TESTED FOR 200 POUNDS OF TENSION. WHEN DRILLED-IN CONCRETE ANCHORS ARE USED FOR BRACING WIRES, 1 OUT OF 2 MUST BE FIELD-TESTED FOR 440 POUNDS OF TEN-SION. SHOT IN ANCHORS IN CONCRETE ARE NOT PERMITTED FOR BRACING WIRES. IF ANY SHOT-IN OR DRILLED-IN ANCHOR FAILS, ALL ADJACENT ANCHORS MUST BE TESTED. 10.ATTACH ALL LIGHT FIXTURES TO THE CEILING GRID RUNNERS TO RESIST A HORIZONTAL FORCE EQUAL TO THE WEIGHT OF THE FIXTURES. 11.FLUSH OR RECESSED LIGHT FIXTURES AND AIR TERMINALS OR SERVICES WEIGHING LESS THAN 56 POUNDS MAY BE SUPPORTED DIRECTLY ON THE RUNNERS OF A HEAVY-DUTY GRID SYSTEM BUT, IN ADDITION, THEY MUST HAVE A MINIMUM OF TWO 12 GA, SLACK SAFETY WIRES ATTACHED TO THE FIXTURE AT DIAGONAL CORNERS AND ANCHORED TO THE STRUCTURE ABOVE, ALL 4 FT. X 4 FT. LIGHT FIXTURES MUST HAVE SLACK SAFETY WIRES AT EACH CORNER. ALL FLUSH OR RECESSED LIGHT FIXTURES AND AIR TERMINALS OR SERVICES WEIGHING 56 POUNDS OR MORE MUST BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN 4 TAUT 12 GA, WIRES EACH ATTACHED TO THE FIXTURE AND TO THE STRUCTURE ABOVE REGARDLESS OF THE TYPE OF CEILING GRID SYSTEM USED. THE 4 TAUT 12 GA, WIRES INCLUDING THEIR ATTACHMENT TO THE STRUCTURE ABOVE MUST BE CAPABLE OF SUPPORTING 4 TIMES THE WEIGHT OF THE UNIT. 12.SUPPORT SURFACE-MOUNTED LIGHT FIXTURES DIRECTLY FROM THE STRUCTURE ABOVE WITH HANGER WIRES OR CABLES PASSING THROUGH EACH PENDANT HANGER AND CAPABLE OF SUPPORTING 4 TIMES THE WEIGHT OF THE FIXTURES (SEE ALSO NOTE 10 ABOVE PROVIDE ADDITONAL SUPPORT WHEN LIGHT FIXTURES ARE 8 FEET OR LONGER. 13.SUPPORT PENDANT-MOUNTED LIGHT FIXTURES DIRECTLY FROM THE STRCUTURE ABOVE WITH HANGER WIRES OR CABLES PASSING THROUGH EACH PENDANT HANGER AND CAPABLE OF SUPPORTING 4 TIMES THE WEIGHT OF THE FIXTURES.(SEE ALSO NOTE 10 ABOVE) 14.ALL CEILING SUSPENSION SYSTEM COMPONENTS SHALL BE" HEAVY DUTY" TYPE WITH COMPONENTS PARTS AS LISTED BELOW. 15.ACOUSTICAL CEILING GRID EXPANSON JOINTS AS NEEDED DEPENDING ON CEILING AREA PER CODE. 16.STABILIZER BARS, CROSS TEES OR OTHER SUITABLE MEANS O PREVENT SPREADING SHALL BE PROVIDED WITHIN 8" OF EACH WALL 17.SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2" OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL DIRECTIONS. 18.CEILING CLOUDS: PROVIDE HANGING WIRES, BRACE AND COMPRESSION STRUT AS DETAILED. IN ADDITION PROVIDE BRACE WIRES AND COMPRESSION STRUT AT EACH CORNER, REGARDLESS OF THE TYPE OF THE CLOUD. A7.2 ARCHITECTURAL DETAILS AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 05/29/2024 PLAN CHECK SET 240202 Sheet Title Sheet # REVISIONDATEDELTA 07/17/2024 2ND PLAN CHECK SET RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2025 ELECTAL LEGEND J C J S 3 D f DO GFCI AFCI WP RECESSED LINEAR RECESSED LED DOWN LIGHT OC OC E0.0 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 240202 Sheet Title Sheet # REVISIONDATEDELTA MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M ELECTRICAL SYMBOLS & LEGENDS Jazayeri UP UP UP ENTRY ENTRY/EXIT COPY/PRINTER/MAIL ADA LIFT ADA U.C.R. CONFERENCE RM LOUNGE TV ADA DISHWASER OFFICE 104 LOUNGE 101 MEETING ROOM 102 OFFICE 105 OFFICE 106 OFFICE 107 OFFICE 108 OFFICE 109 OFFICE 110 OFFICE 111 OFFICE 119 OFFICE 120 OFFICE 121 OFFICE 122 OFFICE 123 OFFICE 124 STORAGE 126 OFFICE 125 OFFICE 117 OFFICE 116 HALLWAY 1 103 HALLWAY 2 118 UNISEX 114 UNISEX 115 PRINT 112 ENTRY 113 ELECTRICAL LIGHTING LAYOUT FIRST FLOOR LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1LT-1LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-6 LT-1 LT-1 LT-2LT-2LT-2LT-2LT-2LT-2LT-2LT-2 LT-2LT-2LT-2LT-2LT-2LT-2 LT-2LT-2 LT-3 LT-3 LT-3 LT-3 LT-10 LT-5 LT-6 LT-7LT-8 LT-4 LT-12 LT-1 LT-1 LT-1 LT-5 LT-5 LT-13 UCL UCL LT-13 LT-12 LT-1 LT-1 LT-1 LT-1 LT-1LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-4 LT-9 LT-11 LT-12 LT-4LT-4LT-4LT-4 DO DO DO DO DO DO DO DO DO DO DO DO DO DO DO O D DO DO D D D D D D OC OC OC D DO OC OC LT-14 LT-14 LT-10 LT-14 LT-14 LT-14 EX-1 EX-1 EX-1 EX-1 EX-1 EX-1 E1.0 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 240202 Sheet Title Sheet # REVISIONDATEDELTA MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M LIGHTING PLAN FIRST FLOOR Jazayeri ELECTRICAL LIGHTING LAYOUT SECOND FLOOR DO STORAGE M01 STORAGE M02 UTILITY M03 DN DN DN DN DN OC DO OC OC LT-14 LT-14 LT-14 LT-14 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-5 LT-5 LT-5LT-5 EX-1 EX-1 EX-1 EX-1 E1.1 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 240202 Sheet Title Sheet # REVISIONDATEDELTA MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M LIGHTING PLAN SECOND FLOOR Jazayeri ELECTRICAL POWER LAYOUT FIRST FLOOR GFCI GFCI GFCI3'-6"3'-6"3'-6" 4'-6" GFCI 3'-6" GFCI 3'-6" 3'-6"3'-6"3'-6" UP UP UP ENTRY ENTRY/EXIT COPY/PRINTER/MAIL ADA LIFT DN ADA U.C.R. CONFERENCE RM LOUNGE TV ADA DISHWASER OFFICE 104 LOUNGE 101 MEETING ROOM 102 OFFICE 105 OFFICE 106 OFFICE 107 OFFICE 108 OFFICE 109 OFFICE 110 OFFICE 111 OFFICE 119 OFFICE 120 OFFICE 121 OFFICE 122 OFFICE 123 OFFICE 124 STORAGE 126 OFFICE 125 OFFICE 117 OFFICE 116 HALLWAY 1 103 HALLWAY 2 118 UNISEX 114 UNISEX 115 PRINT 112 ENTRY 113 WH-2 WH-2 WH-3 E2.0 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 240202 Sheet Title Sheet # REVISIONDATEDELTA MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M POWER PLAN FIRST FLOOR Jazayeri ELECTRICAL POWER LAYOUT SECOND FLOOR STORAGE M01 STORAGE M02 UTILITY M03 DN DN DN DN DN MP-1 FC-2 CU-2 CU-1 FC-1 COPPER BAR, SIZE AS SPECIFIED, HOLES (PLAIN OR TAPPED) AS SPECIFIED INSULATORS STEEL BRACKETS GROUND WIRE LUG SIZED PER DRAWINGS GROUND WIRE BONDED TO THE CONTAINER STRUCTURE BONDED TO THE SITE GROUND ROD 1001 GROUND BAR DETAIL NTS 1002 ELECTRICAL ROOM GROUNDING DETAIL NTS E2.1 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 240202 Sheet Title Sheet # REVISIONDATEDELTA MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M POWER PLAN SECOND FLOOR Jazayeri (N) METER MAIN 400A/2P MAIN M-1 FULL NEUTRAL BUS FULL GRND. BUS TO UTILITY POINT OF CONNECTION IN U.G TRENCH (MINM. 36" BELOW SURFACE) #4CU. GND. UFER GROUND (N) PANEL 'MP-01', 240/120V, 1Ø, 3W+G ELECTRICAL ONE-LINE DIAGRAM ELECTRICAL PANEL SCHEDULE (N) PANEL 'MP-01', 240/120V, 1Ø, 3W+G 3 #500 KCMIL AND 1 #3G IN 4 " UNDERGROUND CONDUIT TYPE DESCRIPTION NOTES /TYPE DESCRIPTION SYMBOL SPEC REMARKS POWER CONSUMPTION LED VANITY LIGHT OUTDOOR LINEAR WET RECESSED LED LED WALL SCONE SYMBOL SPEC DWELED PARALLAX LED VANITY LIGHT18", 3500K NODES DOUBLE SCONCE KWL1012BBS LED, T4, 60W 4" RECESS LEDLT-1 DOWN LIGHTS MUUTO RIME PENDANT LAMP Ø 9.8",E12 3000K ULTRA THIN LED BUILT-IN UNDER CABINET INVISIBLE LIGHT BAR DC12V, 10W/M, EMITTING COLOR - WHITE, MILKY SILICONE COVER LT-2 LT-3 LT-4 LT-5 LT-6 LT-7 LT-8 LT-9 LT-10 LT-11 LT-12 LT-13UCL OUTDOOR LED WALL SCONE COMMERCIAL OUTDOOR LED SIGN LIGHTS LED PENDANT TRACK LIGHT 4" ADJUSTABLE RECESSED LED DOWN LIGHT SATCO # STC676938 H SERIES 2" LED 120V SMALL CYLINDER TRACK HEAD WHITE - 24° 3000K RAYON 4" LED COMMERCIAL DOWNLIGHT #RVC4 - 50° 4000K RAYON #PRIME 4" LED ARCHITECTURAL ROUND FLANGED ACCENT TRIM ADJUSTABLE - 30° 4000K 4" ADJUSTABLE RECESSED LED DOWN LIGHT RAYON 4" LED COMMERCIAL DOWNLIGHT #RBC4-FN 3500K ELITE #OLS-R-LED-4 4000K 4"X48" ARCHITECTURAL LED RECESSED LINEAR LED PANDANT WEST ELM LINEAR WOOD LED PENDANT Walnut 42" 16W, 3000K, DIMMABLE LED PANDANT HUXE AFFONSA LED OUTDOOR WALL LIGHT 3000K TBD ALCON LIGHTING #12100-8-R-CRxx CONTINUOUS RUN 0.8 INCH 4000K LIGHTING SCHEDULE T/C T/C-1 (0-2 HRS OVERRIDE) T/C-1 C-1 MP1-31 MP1-33 MP1-34 MP1-35 MP1-36 MP1-37 MP1-38 LIGHT FIXTURES LIGHT FIXTURES LIGHT FIXTURES LIGHT FIXTURES LIGHT FIXTURES LIGHT FIXTURES LIGHT FIXTURES LIGHTING SHUT-OFF CONTROL DIAGRAM LIGHT FIXTURES LIGHT FIXTURES LIGHT FIXTURES LIGHT FIXTURES LIGHT FIXTURES MP1-39 MP1-40 MP1-41 20W 16W 16W 22W 36W 40W BATTERY LIGHT WALL MOUNTED EMERGI-LITE 12PR72M-2-LILT-14 WITH 90MIN BATTERY ULINE H-1663EX-1 EXIT SIGN E3.0 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 240202 Sheet Title Sheet # REVISIONDATEDELTA MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M ELECTRICAL ONE-LINE & SCHEDULE Jazayeri E4.0 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 240202 Sheet Title Sheet # REVISIONDATEDELTA MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M TITLE-24 Jazayeri AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 240202 Sheet Title Sheet # REVISIONDATEDELTA 05/29/2024 1ST PLAN CHECK SET MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 07/17/2024 2ND PLAN CHECK SET MECHANICAL LEAD SHEET M-00 THIS PROJECT SHALL COMPLY WITH THE: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA EXISTING BUILDING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA ENERGY CODE WITH ALL CITY OF ARCADIA AMENDMENT. MECHANICAL SHEET INDEX SHEET #SHEET NAME P-02 PLUMBING LEAD SHEET P-01 PLUMBING FLOOR PLANS ” LEGEND FLEX. CONN. VD AVD BDD MD RISE OR DROP IN DIRECTION OF AIR FLOW MANUAL VOLUME DAMPER BACKDRAFT DAMPER AUTOMATIC VOLUME DAMPER SINGLE LINE DUCT WORK FLEXIBLE DUCT MODULATING DAMPER EXHAUST DUCT, SECTION FLEXIBLE CONNECTION TURNING VANES SPLITTER DAMPER EXTRACTOR AT BRANCH DUCT RETURN DUCT, SECTION SUPPLY DUCT, SECTION DUCT WORK (WIDTHxDEPTH) AD FD RR/RAG SD/SAD SWR LD SWE ER VAV UC DL DUCT SMOKE DECTECTOR SIDE WALL RETURN OR EXHAUST UNDER CUT DOOR LINEAR DIFFUSER VARIABLE AIR VOLUME SIDE WALL SUPPLY REGISTER EXHAUST REGISTER RETURN REGISTER/RETURN AIR GRILL DOOR LOUVER THERMOSTAT SUPPLY DIFFUSER/ SUPPLY AIR DIFFUSER UL LISTED FIRE DAMPER APPROVED BY FIRE MARSHALS ACCESS DOOR DUCT TRANSITION, ROUND AND RECTANGULAR LINED DUCT WORK (WIDTHxDEPTH DIMENSIONS ARE FOR I.D.) DSD OUTSIDE AIR VENTILATION CALCULATION TOTAL AREA (SQFT)OCUPATION TYPE VENTILATION PER SQFT VENTILATION PER PERSON OCCUPANCY PER ARCH. 2,500 OFFICES 0.06 CFM/SQFT 5 CFM/PERSON 42 OFFICE: Vbz (M)= Rp X Pz + Ra X Az Vbz = 5 CFM/PERSON X 42 PERSON + 0.06 CFM /SQFT X 2500 SQFT = 360 CFM TOTAL REQUIRED OSA FOR THE SPACE 414 CFM TOTAL PROVIDED PER DESIGN 250 CFM THROUGH MECHANICAL UNITS TOTAL OF 500 CFM NOTES: CALCULATION ARE BASED ON TABLE 402.1 FROM CALIFORNIA MECHANICAL CODE. GRILLES AND REGISTERS SCHEDULE MARK MANUFACTURER MODEL FINISH DESCRIPTION VOLUME DAMPER REMARKS A PRICE INDUSTRIES SCD AS PER ARCH/ID 24"X24" RECTANGULAR FACE LAY IN DIFFUSER YES NICK SIZE PER PLANS. C PRICE INDUSTRY AMCD AS PER ARCH/ID SUPPLY AIR GRILL FACE SIZE PER PLAN YES TYPICAL FOR SIDE WALL REGISTERS AND RR REGISTERS NICK SIZE PER PLANS. 3 OR 4 WAY R1 PRICE INDUSTRIES PDDR AS PER ARCH/ID PERFORATED RETURN GRILL LAY IN DIFFUSER YES NICK SIZE PER PLANS. CEILING SUPPORT 1" MIN. ACOUSTICAL LINING SYSTEM CEILING CONNECTING DUCT LOCATION (SEE NOTE) ALTERNATE DUCT SIDE THAN THE MIN. BOX WIDTH ON LIGHTS OR OTHER AS REQ'D TO CLEAR S.M. BOX, HEIGHT SHOP FABRICATED CONSTRUCTIONS, DUCT CONNECTION SIDE SHALL BE 2" WIDER ON EACH FACE CEILING REGISTER (FRAME TO MATCH CEILING TYPE) SQUARE OR RECTANGULAR VOLUME DAMPER SPECIFICATIONS) TYPICAL DUCT BAND, CONICAL SPIN-IN DUCT SIZES ON PLANS (SEE ACOUSTICAL FLEX: SIZE TO BE EQUIVALENT TO RECTANGULAR STAINLESS STEELAIRTIGHT SEAL W/ PER PLAN MINIMUM HEIGHT IS: FLEX DUCT DIAMETER +3" DX SPLIT FAN COIL INDOOR UNITS SCHDULE FC MARK MANUFACTURER & MODEL NUMBBER AREA SERVED FILTER NOMINAL CAPCITY CFM FAN HP ESP ELECTRICAL OUTDOOR UNIT OPERATING WEIGHT (LBS)V/P MCA MCOP FC-1 SAMSUNG AM060JNZDCH/AA BASEMENT FLOOR MERV 13 60,000 1,800 3/4 1.00 208/1 2.60 15 CU-1 200 NOTES: 1. FUSED DISCONNECT PROVIDED BY ELECTRICAL CONTRACTOR 2. PROVIDE MATCHING OUTDOOR CONDENSING UNIT. REFER TO CU SCHEDULE. 3. PROVIDE WITH OWNER APPROVED SMART THERMOSTATE. INSTALL DUCT SMOKE DETCTOR. 5. REFER TO DETAIL 1/M-00 FOR HORIZONTAL INSTALLATION & DETAIL 6/M-00 FOR VERTICAL INSTALLATION. 6. INSTALL MERV 13 WITH FILTER RACK FOR ALL RETURN & OUTSIDE AIR CONNECTIONS. DX SPLIT SYSTEM HEAT PUMP SCHEDULE CU MARK MANUFACTURER & MODEL NUMBBER AREA SERVED NOMINAL COOLING NOMINAL HEATING EQUIPMENT SERVED OPERATING WEIGHT (LBS) ELECTRICAL SEER2 HSPF2 EER2 V/PH MCA MOCP CU-1 SAMSUNG AM060MXMDCH/AA HALF OF THE BUILDING 60,000 66,000 FC-1 300 208/1 32 50 16.5 9.5 9.9 NOTES 1. FUSED DISCONNECT PROVIDED BY ELECTRICAL CONTRACTOR 2. REFRIGERANT PIPING BETWEEN CU & FC SHALL BE SIZED PER MANUFACTURER RECOMMENDATIONS AND ROUTED THE SHORTEST WAY POSSIBLE. 3. REFRIGRANT TYPE R410A. 4. REFER TO DETAIL 5/M-00 FOR INSTALLATION DETAIL. DUCT INSTALLATION & INSULATION SHALL COMPLY WITH 2022 T24 AND AS BELOW (REFER TO MANDATORY MEASURES ON SHEET M-03 FOR ADDITIONAL REQUIREMENTS): -DUCT LOCATED WITHIN DROP CEILING OR IN BETWEEN STRUCTURAL JOISTS SHALL HAVE A 1" INSULATION NOT LESS THAN R4.2 VALUE TO PREVENT CONDENSATION. -DUCT LOCATED IN UNCONDITIONED SPACE SHALL HAVE A MINIMUM OF 2" INSULATION AND NOT LESS THAN R8 VALUE. -DUCT LOCATED WITHIN VENTILATED ROOF ATTIC SHALL HAVE A MINIMUM OF 2" INSULATION AND NOT LESS THAN R8 VALUE. -EXPOSED DUCT SHALL BE SPIRAL PAINTED PER ARCH. PLANS. EXPOSED DUCT WORK TO CONDITIONED AREA'S SHALL BE PERMITTED TO BE INSTALLED WITHOUT INSULATION. -DUCT PLENUMS SHALL BE LINED WITH 1" INSULATION. -DUCT SUPPORT SHALL CONFIRM TO MANUFACTURER RECOMMENDATIONS, CMC & SMACNA GUIDELINES. -DUCT LOCATED WITHIN DROP CEILING OR STRUCTURAL JOIST SHALL BE PERMITTED TO HAVE THE LAST 5' OF RUN TO THE DIFFUSER OF FLEX DUCT THAT COMPLIES WITH CMC. CU-2 SAMSUNG AM060MXMDCH/AA 60,000 66,000 FC-2 300 208/1 32 50 16.5 9.5 9.9HALF OF THE BUILDING FC-2 SAMSUNG AM060JNZDCH/AA BASEMENT FLOOR MERV 13 60,000 1,800 3/4 1.00 208/1 2.60 15 CU-1 200 450 LOUNGE & REC.0.12 CFM/SQFT 5 CFM/PERSON 5 LOUNGE: Vbz (M)= Rp X Pz + Ra X Az Vbz (M)= 20 CFM/PERSON X 260 PERSON + 0.18 CFM /SQFT X 450 SQFT = 79 CFM EXHAUST FAN SCHEDULE EF TAG MANUFACTURER & MODEL NUMBBER AREA SERVED LOCATION SONES HUMIDITY SENSOR ELECTRICAL EXHAUST (CFM) SP (IN.WG)OPERATING WEIGHT (LBS) NOTES V/PH WATSS EF-1 NUTONE AERN80K RESTROOM CEILLING 0.8 NO 120/1 27 80 0.1 20 1 TO 4 EF-2 CEILLING 0.8 NO 120/1 27 80 0.1 20 1 TO 4 EF-3 PANASONIC FV-30NLF1 LOUNGE INLINE -NO 120/1 300 300 0.4 40 1 TO 5 NOTES: 1. FUSED DISCONNECT PROVIDED BY ELECTRICAL CONTRACTOR. 2. INSTALL BACKDRAFT DAMPER WITH WALL/ROOF JACK TERMINATION. 3. REFER TO DETAIL 4/M-00 FOR CEILING EXHAUST FAN & 7/M-00 FOR INLINE FAN INSTALLATION DETAILS. 4. FAN SHALL BE INTERLOCKED WITH OCCUPANCY SENSOR. EF-3 SHALL BE INTERLOCKED TO FC-1 & FC-2 AND SHALL OPERATE WHEN THE UNITS ARE IN OCCUPANCY MODE & ON. 5. INSTALL CEILLING ACCESS PANEL MATCHING CEILLING FIRE RATING IF ANY. 1 SLOT 112" WIDTH, LENGTH PER PLANSBSHOEMAKERLCDAS PER ARCH/ID YES NICK SIZE PER PLANS. INSTALL WHERE INDICATED ON PLANS. LENGTH PER PLANS. R2 SHOEMAKER LINEAR-SS AS PER ARCH/ID 1 SLOT 112" WIDTH, LENGTH PER PLANS YES R3 PRICE INDUSTRIES 600 AS PER ARCH/ID ALUMINUM LOUVERED RETURN GRILL YES NICK SIZE PER PLANS.RETURN WITH 45° DEFLECTION 3/4 IN. BLADE SPACING NICK SIZE PER PLANS. INSTALL WHERE INDICATED ON PLANS. LENGTH PER PLANS. NOTES: -INSTALL LINEAR DIFFUSER/GRILL WITH FACTORY PROVIDED PLENUM. -WHERE DIFFUSER/GRILL MANUFACTURED WITH RECTANGULAR OUTLET/INLET, INSTALL DUCT TRANSITION TO ROUND. -FINISHES SHALL BE PER ARCH./ID PLANS. NUTONE AERN80K RESTROOM MECHANICAL SHEET INDEX SHEET #SHEET NAME M-00 MECHANICAL LEAD SHEET M-01 MECHANICAL FLOOR PLAN M-02 MECHANICAL ENERGY COMPLIANCE M-03 MECHANICAL ENERGY MANDATORY MEASURES M-04 ENVELOPE ENERGY COMPLIANCE UP UP UP F.E. F. E . DNDN DN DN DN AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 240202 Sheet Title Sheet # REVISIONDATEDELTA 05/29/2024 1ST PLAN CHECK SET MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 07/17/2024 2ND PLAN CHECK SET MECHANICAL GENERAL NOTES: 1.AIR FILTERS FOR RETURN AIR & FRESH AIR SHALL HAVE MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 13. INSTALL WITHIN RETURN PLENUM WITH AP. 2.IT'S THE CONTRACTOR RESPONSIBILITY TO BALANCE THE AIR SYSTEM PER THE CFM ASSIGNED ON PLANS. INSTALL VOLUME DAMPER AS NEEDED. 3.MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE PLUMBING CONTRACTOR ON SITE TO RELOCATE ANY PLUMBING VENT WITHIN 10' OF ANY OUTSIDE AIR SOURCE. 4.ALL EXHAUST AND FRESH AIR OPENING TO THE OUTSIDE SHALL BE EQUIPPED WITH A BACK DRAFT DAMPER / GRAVITY DAMPER. N 6&$/E   ME&+$NI&$/ )IR67 )/22R RE)/E&7E' &EI/ING 3/$N61 MECHANICAL FLOOR PLAN M-01 N 6&$/E   ME&+$NI&$/ 6E&2N' )/22R RE)/E&7E' &EI/ING 3/$N61 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 240202 Sheet Title Sheet # REVISIONDATEDELTA 05/29/2024 1ST PLAN CHECK SET MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 07/17/2024 2ND PLAN CHECK SET MECHANICAL ENERGY COMPLIANCE M-02 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 240202 Sheet Title Sheet # REVISIONDATEDELTA 05/29/2024 1ST PLAN CHECK SET MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 07/17/2024 2ND PLAN CHECK SET MECHANICAL ENERGY MANDATORY MEASURES M-03 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 240202 Sheet Title Sheet # REVISIONDATEDELTA 05/29/2024 1ST PLAN CHECK SET MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 07/17/2024 2ND PLAN CHECK SET ENVELOPE ENERGY COMPLIANCE M-04 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 240202 Sheet Title Sheet # REVISIONDATEDELTA 05/29/2024 1ST PLAN CHECK SET MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 07/17/2024 2ND PLAN CHECK SET PLUMBING LEAD SHEET P-00 PLUMBING GENERAL NOTES 1.PLUMBING WORK SHALL COMPLY WITH 2022 CALIFORNIA PLUMBING CODES AND CITY OF ARCADIA AMENDMENTS. 2.PLUMBING EQUIPMENT SHALL BE APPROVED AND TESTED UNDER APPROVED AGENCY FOR CITY OF ARCADIA. 3.EACH HORIZONTAL DRAINAGE PIPE SHALL BE PROVIDED WITH CLEANOUTS AT ITS UPPER TERMINAL, AND EACH RUN OF PIPING, THAT IS MORE THAN 100 FEET IN TOTAL DEVELOPED LENGTH, SHALL BE PROVIDED WITH CLEANOUTS FOR EACH 100 FEET, OR FRACTION THEREOF, IN LENGTH OF SUCH PIPING. ADDITIONAL CLEANOUTS SHALL BE PROVIDED IN A DRAINAGE LINE FOR EACH AGGREGATE HORIZONTAL CHANGE IN DIRECTION EXCEEDING 135 DEGREES. CLEANOUTS SHALL BE INSTALLED ABOVE KITCHEN SINK AND LAVATORY CONNECTION FITTING, SERVING EACH FIXTURE. 4.SANITARY SEWER LINE TO SLOPE @ 2% UNLESS NOTED OTHERWISE. CONTRACTOR TO FIELD VERIFY EXISTING SS LINE SLOPE. 5.CONTRACTOR TO VERIFY POINT OF CONNECTION PRIOR ANY INSTALLATION. 6.ALL VALVES AND FITTING TO SAME SIZE AS PIPE SIZE. 7.FLOOR DRAINS SHALL HAVE A TRAP PRIMER. 8.UNIONS SHALL BE PROVIDED PRIOR TO ANY EQUIPMENT CONNECTION. 14.SLEEVES SHALL BE PROVIDED FOR PIPING PASSING THRU MASONRY OR CONCRETE FLOORS/WALLS. 15.PLUMBING FIXTURE SHALL MEET 2022 CPC REQUIREMENTS PER CHAPTER 4 AND CITY AMENDMENT FIXTURE FLOW. 16.DOMESTIC WATER LINE SHALL BE DISINFECTED PER 2022 CPC. 17.WET VENT SHALL NOT EXCEED 6' IN LENGTH. 18.WATER PIPES AND FITTINGS WITH A LEAD CONTENT WHICH EXCEEDS 0.25% SHALL BE PROHIBITED IN SYSTEMS CONVEYING POTABLE WATER. (CPC604.2) 19.THE PRESSURE REGULATING VALVE (PRV) SHALL BE ACCESSIBLY LOCATED ABOVEGROUND OR IN A VAULT EQUIPPED WITH A PROPERLY SIZED AND SLOPED DRAIN TO DAYLIGHT. THE PRV SHALL NOT BE INSTALLED IN A PIT WHERE IT CAN BECOME SUBMERGED IN WATER. (CPC608.2) 20.DOMESTIC WATER HEATING SYSTEM SHALL COMPLY WITH WAEC AND CITY AMENDMENT. 21.CONTRACTOR SHALL FIELD VERIFY ALL EXISTING UTILITIES PRIOR ANY INSTALLATION AND REPORT ANY DISCREPANCIES. 22.CONTRACTOR SHALL INCLUDE IN HIS BID LOCATING EXISTING UTILITIES LINES. 23.CONTRACTOR SHALL FIELD VERIFY EXISTING WATER PRESSURE AND REPORT ANY DISCREPANCIES. 24.IT'S THE CONTRACTOR RESPONSIBILITIES TO PROVIDE ALL THERMAL EXPANSION LOOP TO COMPLY WITH THE PIPING MANUFACTURER RECOMMENDATIONS. PIPE MATERIAL SCHEDULE DOMESTIC WATER (2 ) B A N D NO - H U B CA S T I R O N SC H E D U L E 80 P V C TY P E M CO P P E R TY P E L CO P P E R TY P E K CO P P E R SC H E D U L E 40 B L A C K ST E E L SC H E D U L E 40 G A L V . ST E E L CP V C PV C AB S CA S T I R O N PR E S S U R E PI P E NOTES INSIDE C & H WATER ABV FLOOR UNDER SLAB THRU SLAB OUTSIDE MUST BE SLEEVED, PVC USED FOR EXTERIOR BUILDING SUPPLY MUST BE SLEEVED, PVC USED FOR EXTERIOR BUILDING SUPPLY SS, VENT & SD RISERS THRU ALL FLOORS BELOW SLAB (UNDERGROUND) NO HUB CAST IRON, 2-BAN- NO HUB COUPLINGS PVC DWV (AS APPROVED PER AHJ) CONDENSATE ABV FLOOR AS APPROVED PER AHJ INDIRECT WASTE ABV FLOOR AS APPROVED PER AHJ *USE COPPER TYPE L WITH THE APPROPRIATE INSULATION FOR PIPE CONNECTION TO WATER HEATER, PIPE EXPOSED OUTDOOR AND ROOF. PLUMBING LEGENED AND ABBREVIATIONS SYMBOL ABBREVIATION DESCRIPTION CW DOMESTIC COLD WATER HW DOMESTIC HOT WATER HWR DOMESTIC HOT WATER RETURN SS SANITARY SEWER SS BG SANITARY SEWER BELOW GROUND SD STORM DRAIN SD BG STORM DRAIN BELOW GROUND V PLUMBING VENTS GAS STANDARD PRESSURE GAS MPG MEDIUM PRESSURE GAS PCD PRIMARY CONDENSATE SCD SECONDERY CONDENSATE HB HOSE BIB DN PIPE DOWN UP PIPE UP DS DOWNSPOUT P.O.C POINT OF CONNECTION RD ROOF DRAIN OD OVERFLOW DRAIN AD AREA DRAIN FD FLOOR DRAIN ED EMERGENCY DRAIN TD TRENCH DRAIN FS FLOOR SINK WCO WALL CLEAN OUT YCO YARD CLEAN OUT COTG CLEAN OUT TO GRADE FCO FLOOR CLEAN OUT SR SUD RELIEF IRR IRRIGATION ABV ABOVE BLW BELOW SS SD BG SD GASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASMPG PCD SCD SR IRR MODEL NUM.MARK PLUMBING FIXTURE SCHEDULE DESCRIPTION COLDVENTSS HOT PIPE SIZES SERVICE PIPE MATERIAL TOTAL WATER DEMAND WATER PRESSURE CALCULATION TOTAL SANITARY SEWER DEMAND WATER PIPE SIZING LAVATORY - UNDERMOUNTL-1 AS SPECIFIED BY OWNERSHIP. MAXIMUM FAUCET FLOW 0.5 GPM @ 60 PSI WATER CLOSET - ADAWC-1 AS SPECIFIED BY OWNERSHIP. MAXIMUM FLOW 1.28 GPF. FLUSH VALVE SYSTEM ONLY 3" KITCHEN SINKKS-1 AS SPECIFIED BY OWNERSHIP. MAXIMUM FAUCET FLOW 1.8 GPM @ 60 PSI 2"114"-- 2"2"12"12" 2"2"12"12" THIS PROJECT SHALL COMPLY WITH THE: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA EXISTING BUILDING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA ENERGY CODE WITH ALL CITY OF ARCADIA AMENDMENT. PLUMBING SHEET INDEX SHEET #SHEET NAME P-00 PLUMBING LEAD SHEET P-01 PLUMBING FLOOR PLANS PLUMBING GENERAL SPECIFICATIONS 1. SCOPE THE WORK SPECIFIED UNDER THIS CONTRACT INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS, TOOLS, TRANSPORTATION, SERVICES, PERMITS, INSPECTION FEES, ETC., REQUIRED IN THE COMPLETE INSTALLATION OF PLUMBING WORK AS SPECIFIED HEREIN AND SHOWN ON ACCOMPANYING DRAWINGS AND AS REQUIRED BY THE CONDITIONS AT THE SITE. THE GENERAL AND SPECIAL CONDITIONS ARE HEREBY MADE A PART OF THIS SECTION. IN ADDITION, WORK IN THESE SECTIONS ARE GOVERNED BY ALL PROVISIONS OF THE CONTRACT DOCUMENTS. 2. SUBMITTALS SUBMIT SHOP DRAWINGS AND ALL DATA REQUIRED IN ACCORDANCE WITH DETAILED REQUIREMENTS OF DIVISION 1, GENERAL REQUIREMENTS, FOR ALL WORK PROVIDED UNDER DIVISION 15. 3. RECORD DRAWINGS PROVIDE RECORD DRAWINGS WHICH SHALL CLEARLY SHOW ALL DIFFERENCES BETWEEN THE CONTRACT WORK AS DRAWN AND INSTALLED. PIPING MAINS BELOW SLAB AND/OR GRADE AND ALL BRANCH LINES BELOW SLAB OR GRADE IN EXCESS OF 5 FT. IN LENGTH SHALL BE DIMENSIONED FROM COLUMNS OF ANY PERMANENT STRUCTURE. ALSO, SHOW ALL WORK ADDED TO THE CONTRACT WHICH IS NOT SHOWN ON THE CONTRACT DRAWINGS. RECORD DRAWINGS SHALL BE IN ACCORDANCE WITH DIVISION REQUIREMENTS. 4. EQUIPMENT LIST AND MAINTENANCE MANUAL MAINTENANCE MANUAL SHALL INCLUDE ALL AVAILABLE MANUFACTURERS' OPERATION AND MAINTENANCE INSTRUCTIONS TOGETHER WITH THE RECORD DRAWINGS HERE IN BEFORE SPECIFIED AND ALL OTHER DIAGRAMS AND INSTRUCTIONS NECESSARY TO PROPERLY OPERATE AND MAINTAIN THE EQUIPMENT. THE MANUAL SHALL ALSO INCLUDE THE NAME, ADDRESS, AND PHONE NUMBER OF THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS INVOLVED IN ANY OF THE WORK SPECIFIED HEREIN. THE EQUIPMENT LIST AND MAINTENANCE MANUAL SHALL BE SUBMITTED IN ACCORDANCE WITH DIVISION 1, GENERAL REQUIREMENTS. 5. CODES, PERMITS, FEES, INSPECTIONS, RULES & REGULATIONS THE CONTRACTOR MUST, AT HIS OWN EXPENSE, OBTAIN ALL NECESSARY PERMITS, PAY ALL LEGAL FEES AND CHARGES INCLUDING WATER AND SEWER DEVELOPMENT FEES, AND COMPLY WITH ALL STATE AND MUNICIPAL BUILDING AND SAFETY LAWS, ORDINANCES AND REGULATIONS, RELATING TO BUILDING AND PUBLIC HEALTH AND SAFETY. ALL WORK SHALL BE IN CONFORMANCE WITH THE GOVERNING CITY CODES. 6. EXCAVATION AND BACKFILL COMPLETE ALL SAW CUTTING, EXCAVATION AND BACKFILL AS NECESSARY FOR THE INSTALLATION OF UNDERGROUND PIPING. COMPACT AND TAMP BACKFILL TO ORIGINAL GRADE IN ACCORDANCE WITH REQUIREMENTS AS SPECIFIED IN SECTION ENTITLED "EARTHWORK" AND REMOVE EXCESS DIRT AS DIRECTED. NO WORK SHALL BE COVERED UNTIL PROPERLY TESTED AND APPROVED. ALL PAVEMENT, SIDEWALK, PIPING, ELECTRICAL CONDUIT, ETC., CAUSED TO BE CUT OR DAMAGED BY THIS SECTION SHALL BE RESTORED TO ORIGINAL CONDITION BY WORKMEN QUALIFIED AND ACTIVE IN THE TRADES INVOLVED. 7. ELECTRIC WIRING ALL POWER WIRING IS INCLUDED IN DIVISION 16, ELECTRICAL. THE RESPONSIBILITY FOR PROPER CONNECTIONS AND OPERATION IS INCLUDED UNDER THIS DIVISION. 8. WARRANTY WARRANT THE SYSTEM, LABOR, MATERIALS AND EQUIPMENT FOR ONE (1) YEAR AFTER COMPLETION AND ACCEPTANCE. REPLACE OR REPAIR ALL DEFECTIVE WORKMANSHIP, EQUIPMENT, AND MATERIALS AT NO ADDITIONAL COST TO THE OWNER. 9. WORK SPECIFIED HEREIN PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, AND SERVICES NECESSARY TO FURNISH AND INSTALL COMPLETE PLUMBING AND PIPING SYSTEMS AS INDICATED OR SPECIFIED. INSTALL AND DELIVER ALL SYSTEMS COMPLETE, IN PERFECT WORKING ORDER, AND IN FULL ACCORDANCE WITH THE INTENT AND MEANING OF THE DRAWINGS AND SPECIFICATIONS. THE WORK, IN GENERAL, CONSISTS OF, BUT IS NOT NECESSARILY LIMITED TO, THE FOLLOWING: COMPLETE SANITARY PLUMBING SYSTEMS FOR THE BUILDING WITH CONNECTIONS FROM EXISTING LINE IN THE BUILDING. DOMESTIC WATER SYSTEM INCLUDING CONNECTION TO EXISTING STUB OUT, AND CONNECTIONS TO ALL PLUMBING FIXTURES AND EQUIPMENT. ROUGH-IN AND FINAL CONNECTIONS OF WASTE AND WATER TO SPECIAL EQUIPMENT SPECIFIED UNDER OTHER SECTIONS OF THESE SPECIFICATIONS OR SUPPLIED BY OWNER, INCLUDING KITCHEN EQUIPMENT, CONDENSATE DRAIN PIPING, P-TRAPS, WASTE TUBING STOPS, FLEXIBLE TUBE RISERS, ETC. AS REQUIRED. VALVED OUTLETS AND CONNECTIONS TO ALL HEATING, AIR CONDITIONING, OR ELECTRICAL EQUIPMENT WITH LOCATION AS REQUIRED. INSULATION INCLUDING DOMESTIC HOT WATER SUPPLY PIPING AS SPECIFIED. PLUMBING SPECIALTIES, INCLUDING CLEAN-OUTS, DRAINS, FIXTURE SUPPORTS, INTERCEPTORS, ETC. PLUMBING EQUIPMENT AS SPECIFIED AND SCHEDULED. PLUMBING FIXTURES AS SPECIFIED. ADEQUATE SUPERVISION OF ERECTION, BALANCING, ADJUSTMENTS AND INSTRUCTIONS FOR PROPER OPERATION AND MAINTENANCE. PAYMENT FOR ALL PLUMBING PERMITS AND INSPECTION FEES. STERILIZATION OF POTABLE WATER SYSTEM. 10. APPROVED MANUFACTURERS SPECIFICATION HEREIN BY BRAND NAME IS INTENDED TO ESTABLISH A STANDARD OF QUALITY. FURTHER, THIS EQUIPMENT HAS BEEN CHECKED AS TO SIZE AND WEIGHT REQUIREMENTS AND SPACE ALLOCATION HAS BEEN MADE ACCORDINGLY. SUBMITTAL OF EQUIPMENT BY OTHER ACCEPTABLE MANUFACTURERS MUST BE COMPLETE IN EVERY DETAIL, INCLUDING SPACE REQUIREMENTS, WEIGHT, COMPLETE PERFORMANCE DATA, AND SUPPLEMENTAL DATA REQUESTED BY THE ARCHITECT. CONTRACTOR SHALL BE RESPONSIBLE FOR ASSURANCE THAT THE EQUIPMENT MEETS ALL THE REQUIREMENTS DETAILED IN THIS AND OTHER SECTIONS, AND INDICATED ON THE DRAWINGS. EACH SECTION INCLUDES A LIST OF MANUFACTURERS WHOSE EQUIPMENT IS ACCEPTABLE TO MANUFACTURE, SUBJECT TO CONFORMANCE WITH ALL DRAWINGS, SPECIFICATIONS AND ADDENDA ITEMS. CAREFUL CHECKING MUST BE MADE TO VERIFY THAT THE EQUIPMENT WILL MEET ALL CAPACITIES, REQUIREMENTS, SPACE ALLOCATIONS, AND THAT THE WEIGHTS ARE NOT EXCESSIVE. 11. MATERIALS MANUFACTURERS INDICATE A STANDARD OF QUALITY, OTHER MANUFACTURES MUST BE APPROVED AS AN EQUAL. DOMESTIC WATER: TYPE "L" HARD DRAWN COPPER, CONFORMING TO ASTM B-88. CLEAN OUTS: INTERIOR CONCRETE AND TILE FLOORS: "WADE W-7000". INTERIOR FINISHED WALLS: "WADE W-8460-R". BALL VALVES: NIBCO #S-585-70, 150# SOLDER JOINT FOR ALL LINES UP TO 2" IN DIAMETER. CHECK VALVES: NIBCO #S-413-Y, 150# SOLDER JOINT FOR ALL VALVES UP TO 2" IN DIAMETER. GLOBE VALVES: NIBCO #S-235-Y, 150# SOLDER JOINT FOR ALL VALVES UP TO 2" IN DIAMETER. FIXTURES: USE POLISHED CHROME PLATED, ADJUSTABLE BRASS P-TRAPS AND WASTE ARMS WITH WALL ESCUTCHEONS AT ALL EXPOSED LOCATIONS. USE POLISHED CHROME PLATED FAUCETS WITH REMOVABLE TRIP, BRASS BODY AND BRASS HANDLES. FIXTURES AND SUPPLY FITTING SHALL BE AS SPECIFIED. PROVIDE DIAPHRAGM TYPE POLISHED CHROME PLATED FLUSH VALVES WITH INTEGRAL VACUUM BREAKERS AND SCREW DRIVER STOPS. PROVIDE FIXTURE STOPS AND VALVES AHEAD OF ALL EQUIPMENT OR FIXTURES. AFTER FIXTURES ARE SET IN PLACE AND SECURED TO WALLS, CAULK ALL AROUND BETWEEN FIXTURES AND WALL WITH EITHER "DOW CORNING #780" OR G.E. CONSTRUCTION SEALANT" WHITE SILICONE CAULKING COMPOUND. 12. INSTALLATION THE ENTIRE PLUMBING SYSTEM SHALL BE INSTALLED IN A NEAT, WORKMANLIKE, FINISHED, AND SAFE MANNER. CONCEAL ALL PIPING IN FINISHED AREAS UNLESS NOTED OTHERWISE. ALL PIPING SHALL BE ADEQUATELY SUPPORTED AND INSTALLED PARALLEL WITH THE BUILDING WALLS. THE ENTIRE INSTALLATION SHALL BE SUBJECT TO THE ARCHITECT'S APPROVAL. 13. TESTS TEST WATER PIPING TO 100 PSI AND HOLD FOR 4 HOURS. TEST SEWER AND VENT PIPING WITH A 10 FOOT HEAD OF WATER FOR 4 HOURS. REPAIR ALL LEAKS UNTIL SYSTEMS ARE WATERTIGHT. END OF SECTION PLUMBING FIXTURES MAX FLOW RATE RESIDENTIAL LAVATORIES PLUMBING FIXTURE MAX FLOW RATE 1.2 GPM @ 60 psi PUBLIC LAVATORIES 0.5 GPM @ 60 psi METERING FAUCET 0.25 GPC SHOWER HEAD 1.8 GPM @ 80 PSI WATER CLOSET 1.25 GPF URINAL 0.125 GALLONS KITCHEN FAUCET 1.8 GPM @ 60 PSI RE)ER 72 3/$N6 )2R 3I3E 6I=E6 R22) IN67$//$7I2N R22) MEM%R$NE6 &/$M3E' 72 %$6E R22) &2N67R8&7I2N 67R8&78R$/ 'R$WING6 )2R RE)ER 72 $R&+I7E&78R$/ %$6E 6E7 IN M$67I&  6E$/ 3$7E 2R EQ8$/ 638N $/8MIN8M 32/<9IN</&+/2RI'E %227 3$7E 2R EQ8$/ 67E33E' $'-867$%/E &/$M36 7<3I&$/ 67$IN/E66 67EE/ &/$M3 6&REW 7<3 6$NI7$R< 9EN7 3I3ING 7ERMIN$7E  $%29E R22) MIN A NTS VENT TERMINATION THRU ROOF WITH ROOF JACK1 NTS2 NTS3 NTS4 NTS5 NTS6 WATER HEATER GENERAL NOTES: -COLD WATER WITHIN 10' OF WH TO BE COPPER AND INSULATED. -ALL HOT WATER AND HOT WATER RETURN TO BE INSULATED. -INSTALL PER MANUFACTURER RECOMMENDATIONS. -CIRCULATING PUMP SHALL HAVE A HOSE BIB ON EACH SIDE OF THE PUMP ALONG WITH ISOLATING VALVES GALVANIZED SHEET METAL DRAIN PAN STORAGE TANK TYPE ELECTRIC WATER HEATER SECURE WATER HEATER TO WALL WITH (2) 20ga x 1" WIDE GALVANIZED SHEET METAL SEISMIC STRAPS POP-OFF DRAIN LINE FULL SIZE OF UNIT CONNECTION PER CPC 608.5 THERMAL EXPANSION TANK BALL VALVE, TYP ASME RATED PRESSURE AND TEMPERATURE RELIEF VALVE 34" HOT WATER LINE VACUUM RELIEF VALVE CHECK VALVE 3 4" COLD WATER SUPPLY LINE TERMINATE TO THE FS WITH 2" AIR GAP CHECK VALVE CHECK VALVE 1/2" HOT WATER RETURN LINE 34" TMV-1 (LIMIT WATER TEMPERATURE AT 125°F - 4 GPM @ 5 PSI PRESSURE DROP) BALANCING VALVE BV-1 STRAINER CIRCULATING PUMP NTS6 LAVATORY - WALL MOUNTL-2 AS SPECIFIED BY OWNERSHIP. MAXIMUM FAUCET FLOW 0.5 GPM @ 60 PSI 2"2"12"12" DISH WASHERDW AS SPECIFIED BY OWNERSHIP. CONNECT 2" SEWER DISCHARGE THRU AIR GAP TO KITCHEN SINK.2"-12"12" P-02 PLUMBING ENERGY COMPLIANCE FLOOR DRAINFD-1 AS SPECIFIED BY OWNERSHIP. INSTALL MEDIUM DUTY DRAIN WITH HEAL PROOF.PROVIDE TRAP PRIMER FLOW ACTIVATOR UNDER THE LAV.3"12"--2" UP UP UP DN DN F.E. F. E . COPY/PRINTER/MAIL CONFERENCE RM LOUNGE OFFICEOFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICEOFFICEOFFICEOFFICEOFFICEOFFICE OFFICEOFFICE STORAGE M01 STORAGE M02 UTILITY M03 DN DN DN DN DN AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 240202 Sheet Title Sheet # REVISIONDATEDELTA 05/29/2024 1ST PLAN CHECK SET MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 07/17/2024 2ND PLAN CHECK SET PLUMBING GENERAL NOTES: PLUMBING KEY NOTES: 6  &W +W  66 $N' 9EN7 72 /$9$72R<  &W  66 $N'  9EN7 72 W$7ER &/26E7  &W +W  66 $N' 9EN7 72 .I7&+EN 6IN. IN67$ +27 W$7ER +E$7ER &2NNE&7  &W +W /IMI7 +W 7EM3 $7 N2 M2RE 7+$N ƒ) 32IN7 2) &2NNE&7I2N 72 E;I67ING W$7ER /INE )IE/' 9ERI)< E;I67ING 6I=E $N' /2&$7I2N 32IN7 2) &2NNE&7I2N 72 E;I67ING 6$NI7$R< 6EWER /INE )IE/' 9ERI)< E;I67ING /2&$7I2N 6/23E $N' 'E37+ $33R2;IM$7E /2&$7I2N 2) ME&+$NI&$/ EQ8I3MEN76 &2NNE&7  3RIM$R< &2N'EN6$7E 3&' /INE 72 7+E 7$I/ 3IE&E 2) /$9$72R< 3R29I'E 29ER )/2W &87 2)) 6WI7&+ IN /IE8 2) 6E&2N'$R< &2N'EN6$7E  IN67$// &2N'EN6$7E 38M3 )2R 7+E /2NG R8N $N' $6 NEE'E' 72 R$I6E 7+E &2N'EN6$7E /INE )2R &22R'IN$7I2N WI7+ E &EI/ING E/EMEN76 )/22R 'R$IN IN67$//  66  9 WI7+  &W 7R$3 3RIMER 6/23E )/22R 72 )/22R 'R$IN IN &2M3/I$N&E WI7+ $'$ REQ8IREMEN76 $N' %8I/'ING &2'E 1 2 3 4 5 N 6&$/E   3/8M%ING )IR67 )/22R 3/$N1 PLUMBING FLOOR PLAN P-01 DESCRIPTION VENTWASTE ROUGH-IN SERVICES ITEM FIXTURE HOTCOLDWATERWATER N 6&$/E   3/8M%ING ME==$NINE )/22R 3/$N1 &2N7R$&72R 6+$// 9ERI)< E;I67ING 87I/I7< /INE6 3RI2R $N< %I' &2N7R$&72R 6+$// IN&/8'E IN +I6 %I' 7+E &267 2) 7REN&+ING E;&$9$7I2N %E''ING /2&$7ING 87I/I7< /INE6 8N'ERGR28N' $N' 'EM2/I6+ING E;I67ING 3/8M%ING )I;78RE6 I) $N< R8N 66 /INE6 $7 $ 6/23E 2)   I) N27 3266I%/E N27I)< $R&+E2R &2N7R$&72R 72 &22R'IN$7E WI7+ 2WNER RE3 G& )2R $N< 6ER9I&E IN7ERR837I2N $N' 6+$// MINIMI=E '2WN7IME &2N7R$&72R 6+$// &/E$N 6I7E E9ER<'$< $N' 'I6&$R' 7+E 'E%RI6 IN $33R23RI$7E M$NNER 2876I'E 7+E 6I7E $// +W +WR 3I3E6 6+$// %E IN68/$7E' 3ER  &$/I)2RNI$ ENERG< &2'E 7  &2N7R$&72R 6+$// 3R29I'E NEW )I;78RE6 6833/< 67236 W+$ $N' $N< 3/8M%ING )I;78RE $&&E662R< &2N'EN6$7E /INE 6+$// %E 3R27E&7E' IN 3/$&E RE3$IR $6 NEE'E' $N' .EE3 $6 +IG+ $6 3266I%/E #  6/23E $N' &22R'IN$7E $7 6I7E 7ERMIN$7E 72 7+E 7$I/ 3IE&E 2) /$9$72R< &2N7R$&72R 6+$// &$3 $N< E 3/8M%ING 3I3E6 IN )/22R6 W$//6 $N' &EI/ING 7+$7 6ER9E E 3/8M%ING )I;78RE6 %EING REM29E'RE/2&$7E' &2N7R$&72R 6+$// W$/. 7+E 6I7E 3RI2R %I''ING 7+E -2% $N' 6+$// IN&/8'E IN %I' 7+E &267 2) E;7EN'ING M2'I)<ING $N' 83GR$'ING 3/8M%ING /INE6 72 6ER9E 7+E NEW /$<287 $N< 3/8M%ING 3I3E /$RGER 7+$N W+$7 6+2WN 2N 3/$N6 6+$// %E $&&E37$%/E I) 6M$//ER &2N7R$&72R 6+$// RE3/$&E 72 M$7&+ 6I=E6 IN'I&$7E' 2N 3/$N6 &2N7R$&72R 6+$// &22R'IN$7E WI7+ ME&+$NI&$/ &2N7R$&72R 72 RE/2&$7E $N< 3/8M%ING 9EN76 WI7+IN  2) 2876I'E $IR IN7$.E6 7 8 SYMBOL SERVICE LOCATION FUEL TYPE MANUFACTURER & MODEL ELECTRICAL DATA VOLT PHASE (LBS)AMPS OPER. WEIGHT DESCRIPTIONPWR INPUT (KW) GPM OUTPUT THERMAL EFFICIENCY 40°F RISE AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 FOOTHILL OFFICE TI Consultant: Seal: 240202 Sheet Title Sheet # REVISIONDATEDELTA 05/29/2024 1ST PLAN CHECK SET MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 07/17/2024 2ND PLAN CHECK SET PLUMBING ENERGY COMPLIANCE P-02 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 57 E. FOOTHILL BLVD, ARCADIA, CA 91006 WPH Engineering 411 E. Huntington Dr., Ste 313 Arcadia, CA 91006 (626) 658-7974 wph@wphengineering.com INTERIOR OFFICE T.I. 57 E. FOOTHILL BLVE. ARCADIA, CA 91006 JOB #: 24031 DESIGN BASED ON 2022 CBC DESIGN LOADS: ROOF LIVE LOAD:RLL 20 psf×:= ROOF DEAD LOAD:RDL 15 psf×:= MEZZ. LIVE LOAD:FLL 40 psf×:= MEZZ DEAD LOAD:FDL 15 psf×:= CEILING LIVE LOAD:CLL 10 psf×:= CEILING DEAD LOAD:CDL 5 psf×:= EXTERIOR WALL DEAD LOAD: WDL 15 psf×:= INTERIOR WALL DEAD LOAD: WDL2 10psf:= OVERSTRENGTH FACTOR: (FLEXIBLE DIAPHRAGM) Ω 3 0.5-2.5=:= TABLE OF CONTENTS: DESIGN CRITERIA . . . PAGE 2 FRAMING DESIGN . . . PAGE 3 ENERCALC ANALYSIS . . . PAGE 5 FOOTING DESIGN . . . PAGE 8 GURADRAIL DESIGN . . . PAGE 9 Page 1 of 11 USGS web services were down for some period of time and as a result this tool wasn't operational, resulting in timeout error.USGS web services are now operational so this tool should work as expected. 57 E Foothill Blvd, Arcadia, CA 91006, USA Latitude, Longitude: 34.1512212, -118.0289998 Date 4/30/2024, 1:21:41 AM Design Code Reference Document ASCE7-16 Risk Category II Site Class D - Default (See Section 11.4.3) Type Value Description SS 1.979 MCER ground motion. (for 0.2 second period) S1 0.739 MCER ground motion. (for 1.0s period) SMS 2.374 Site-modified spectral acceleration value SM1 1.256 Site-modified spectral acceleration value SDS 1.583 Numeric seismic design value at 0.2 second SA SD1 0.837 Numeric seismic design value at 1.0 second SA Type Value Description SDC D Seismic design category Fa 1.2 Site amplification factor at 0.2 second Fv 1.7 Site amplification factor at 1.0 second PGA 0.862 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 1.034 Site modified peak ground acceleration TL 8 Long-period transition period in seconds SsRT 1.979 Probabilistic risk-targeted ground motion. (0.2 second) SsUH 2.222 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration SsD 2.24 Factored deterministic acceleration value. (0.2 second) S1RT 0.741 Probabilistic risk-targeted ground motion. (1.0 second) S1UH 0.83 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration. S1D 0.739 Factored deterministic acceleration value. (1.0 second) PGAd 0.918 Factored deterministic acceleration value. (Peak Ground Acceleration) PGAUH 0.862 Uniform-hazard (2% probability of exceedance in 50 years) Peak Ground Acceleration CRS 0.89 Mapped value of the risk coefficient at short periods CR1 0.892 Mapped value of the risk coefficient at a period of 1 s CV 1.496 Vertical coefficient Page 2 of 11 24031-Vert - Framing (ROOF).xmcd 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 DESIGN ROOF FRAMING: ROOF LIVE LOAD:RLL 20 psf:=CELING LIVE LOAD:CLL 10 psf:= ROOF DEAD LOAD:RDL 15 psf:=CEILING DEAD LOAD:CDL 5 psf:= MEZZ LIVE LOAD:FLL 50 psf:=EXT. WALL DEAD LOAD:WDL 15 psf:= MEZZ DEAD LOAD:FDL 15 psf:=INT. WALL DEAD LOAD:WDL2 10 psf:= B1) 8'-0" BEAM SUPPORTING EXISTING MEZZ. TRIBUTARY WIDTH FLOOR:TWF 16 FT 2 8ft=:= DEAD LOADING:Wdead FDL TWF120 plf=:= LIVE LOADING:Wlive FLL TWF400 plf=:= SEE ENERCALC FOR DESIGN USE 4x10 DF#1 OR 6x12 DF#1 B2) 11'-0" BEAM SUPPORTING EXISTING MEZZ. TRIBUTARY WIDTH FLOOR:TWF 27 FT 2 13.5ft=:= DEAD LOADING:Wdead FDL TWF202.5 plf=:= LIVE LOADING:Wlive FLL TWF675 plf=:= SEE ENERCALC FOR DESIGN USE 5 1/4x9 1/4 PSL B3) 6'-0" BEAM (RETROFIT EXISTING BEAM) TRIBUTARY WIDTH FLOOR:TWF 24 IN:= DEAD LOADING:Wdead FDL TWFWDL2 5FT+80 plf=:= LIVE LOADING:Wlive FLL TWF100 plf=:= POINT LOADING FROM BEAM B1 AT MID SPAN TRIBUTARY WIDTH FLOOR:TWF 27 FT 2 11FT 274.25ft2=:= DEAD LOADING:Wdead FDL TWF1113.75lb=:= LIVE LOADING:Wlive FLL TWF3712.5lb=:= SEE ENERCALC FOR DESIGN USE 3 1/2x9 1/4 PSL Page 3 of 11 24031-Vert - Framing (ROOF).xmcd B4) 13'-0" HEADER (STORE-FRONT) TRIBUTARY WIDTH CEILING:TWC 5 FT:= DEAD LOADING:Wdead CDL TWCWDL2 10FT+125 plf=:= LIVE LOADING:Wlive CLL TWC50 plf=:= SEE ENERCALC FOR DESIGN USE HSS6x8x1/4 B5) CHECK EXISTING 13'-0" RAFTER FOR NEW RTU TRIBUTARY WIDTH ROOF:TWR 24 IN:= DEAD LOADING:Wdead RDL TWR30 plf=:= LIVE LOADING:Wlive RLL TWR40 plf=:= POINT LOADING FROM RTU AT MID SPAN DEAD LOADING:Pdead 300 lb 2 150lb=:= SEE ENERCALC FOR DESIGN USE DBL. 2x6 OR 4x6 Page 4 of 11 Multiple Simple Beam LIC# : KW-06016329, Build:20.24.07.08 WPH ENGINEERING (c) ENERCALC INC 1983-2023 Project File: 2403.ec6 Project Title:Engineer:Project ID:Project Descr: Description : BEAM Size :4x10, Sawn, Fully BracedUsing Allowable Stress Design with IBC 2021 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2021, ASCE 7-16 Douglas Fir-Larch No.11,000.01,000.0 1,500.0625.0 1,700.0620.0180.0675.0 31.210Eminbend - xx ksi Wood Species : Wood Grade :Fb - Tension psipsi Fv psiFb - Compr Ft psi Fc - Prll psipsiFc - Perp Ebend- xx ksi Density pcf B1) 8'-0" BEAM SUPPORTING EXISTING MEZZ Applied Loads Unif Load: D = 0.120, L = 0.40 k/ft, Trib= 1.0 ft .Design Summary Max fb/Fb Ratio =0.833 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 4.000 inft 78.38 psi Fb : Allowable : 1,200.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.435 : 1 0.000 ft 1,000.17 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max DeflectionsTransient Downward 0.094in Transient Upward 0.000in Total Downward 0.123 in Total Upward 0.000 in 0.48 1.600.48 1.60 Ratio 1016 781Ratio LC: L Only LC: +D+L LC: LC: BEAM Size :5.25x9.25, Parallam PSL, Fully BracedUsing Allowable Stress Design with IBC 2021 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2021, ASCE 7-16 iLevel Truss Joist Parallam PSL 1.8E2,400.02,400.0 2,500.0425.0 1,800.0914.88190.01,755.0 45.070Eminbend - xx ksi Wood Species : Wood Grade :Fb - Tension psipsi Fv psiFb - Compr Ft psi Fc - Prll psipsiFc - Perp Ebend- xx ksi Density pcf B2) 11'-0" BEAM SUPPORTING EXISTING MEZZ Applied Loads Unif Load: D = 0.2025, L = 0.6750 k/ft, Trib= 1.0 ft .Design Summary Max fb/Fb Ratio =0.861 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 5.500 inft 128.20 psi Fb : Allowable : 2,470.35 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 190.00 psi fb : Actual : Max fv/FvRatio =0.675 : 1 0.000 ft 2,127.32 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max DeflectionsTransient Downward 0.359in Transient Upward 0.000in Total Downward 0.466 in Total Upward 0.000 in 1.11 3.711.11 3.71 Ratio 368 283Ratio LC: L Only LC: +D+L LC: LC: Page 5 of 11 Multiple Simple Beam LIC# : KW-06016329, Build:20.24.07.08 WPH ENGINEERING (c) ENERCALC INC 1983-2023 Project File: 2403.ec6 Project Title:Engineer:Project ID:Project Descr: BEAM Size :3.5x9.25, Parallam PSL, Fully BracedUsing Allowable Stress Design with IBC 2021 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2021, ASCE 7-16 iLevel Truss Joist Parallam PSL 1.8E2400240025004251800914.881901755 45.07Eminbend - xx ksi Wood Species : Wood Grade :Fb - Tension psipsi Fv psiFb - Compr Ft psi Fc - Prll psipsiFc - Perp Ebend- xx ksi Density pcf B3) 6'-0" BEAM (RETROFIT EXISTING BEAM) Applied Loads Unif Load: D = 0.080, L = 0.10 k/ft, Trib= 1.0 ft 1Point: D = 1.113, L = 3.712 k @ 3.0 ft .Design Summary Max fb/Fb Ratio =0.783 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 3.000 inft 130.46 psi Fb : Allowable : 2,470.35 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 190.00 psi fb : Actual : Max fv/FvRatio =0.687 : 1 5.240 ft 1,934.83 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max DeflectionsTransient Downward 0.077in Transient Upward 0.000in Total Downward 0.103 in Total Upward 0.000 in 0.80 2.160.80 2.16 Ratio 936 696Ratio LC: L Only LC: +D+L LC: LC: Fy = 46.0 ksi STEEL Section :HSS8x6x1/4, Fully BracedUsing Allowable Strength Design with IBC 2021 Load Combinations, Major Axis Bending E = 29,000.0 ksi Steel Beam Design :B4) 13'-0" HEADER (STORE-FRONT) Calculations per AISC 360-16, IBC 2021, ASCE 7-16 Applied Loads Unif Load: D = 0.3025, L = 0.6750 k/ft, Trib= 1.0 ft 1Point: D = 0.9113, L = 3.038 k @ 3.0 ft .Design Summary Max fb/Fb Ratio =0.696 : 1 Max Reactions (k)HEWSLrL +D+LLoad Comb : Span # 1 Left Support D in 5.547 inft 9.392 k Mn / Omega : Allow 38.792 k-ft Right Support Vn / Omega : Allow Span # 1 Load Comb : +D+L 56.229 k Mu : Applied Max fv/FvRatio =0.167 : 1 0.000 ft 26.998 k-ft at atVu : Applied Ratio 9999 Ratio 9999 Max DeflectionsTransient Downward 0.361in Transient Upward 0.000in Total Downward 0.508 in Total Upward 0.000 in 2.67 6.72 2.18 5.09 306432Ratio LC: L Only LC: +D+L LC: LC: BEAM Size :2-2x6, Sawn, Fully BracedUsing Allowable Stress Design with IBC 2021 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2021, ASCE 7-16 Douglas Fir-Larch No.11,000.01,000.0 1,500.0625.0 1,700.0620.0180.0675.0 31.210Eminbend - xx ksi Wood Species : Wood Grade :Fb - Tension psipsi Fv psiFb - Compr Ft psi Fc - Prll psipsiFc - Perp Ebend- xx ksi Density pcf B5) CHECK EXISTING 13'-0" RAFTERS FOR RTU Applied Loads Unif Load: D = 0.0150, Lr = 0.020 k/ft, Trib= 2.0 ft 1Point: D = 0.150 k @ 6.50 ft . Page 6 of 11 Multiple Simple Beam LIC# : KW-06016329, Build:20.24.07.08 WPH ENGINEERING (c) ENERCALC INC 1983-2023 Project File: 2403.ec6 Project Title:Engineer:Project ID:Project Descr: Design Summary Max fb/Fb Ratio =0.960 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 6.500 inft 45.42 psi Fb : Allowable : 1,625.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+Lr 225.00 psi fb : Actual : Max fv/FvRatio =0.202 : 1 12.567 ft 1,560.00 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max DeflectionsTransient Downward 0.365in Transient Upward 0.000in Total Downward 0.808 in Total Upward 0.000 in 0.27 0.260.27 0.26 Ratio 426 193Ratio LC: Lr Only LC: +D+Lr LC: LC: Page 7 of 11 24031-Footings.xmcd 57 E. FOOTHILL BLVD. ARCADIA, CA 91006 FOOTING DESIGN: DESIGN LOADS: ROOF LIVE LOAD:RLL 20 psf:=CELING LIVE LOAD:CLL 10 psf:= ROOF DEAD LOAD:RDL 15 psf:=CEILING DEAD LOAD:CDL 5 psf:= MEZZ LIVE LOAD:FLL 50 psf:=EXT. WALL DEAD LOAD:WDL 15 psf:= MEZZ DEAD LOAD:FDL 15 psf:=INT. WALL DEAD LOAD:WDL2 10 psf:= ALLOWABLE SOILS BEARING PRESSURE:BRGallow 1500 psf:= F1.) DESIGN CONTINUOUS FOOTING: (TYPICAL) TRIBUTARY WIDTH ROOF:TWR 8 FT 2 4ft=:= TRIBUTARY WIDTH CEILING:TWC 5 FT:= wtot RDL RLL+( ) TWRCDL CLL+( ) TWC+WDL 18 FT( )+485 plf=:= TRY ftgw 18 in:=BRGallow 1500 psf= BRGactual wtot ftgw :=BRGactual 323.333 psf=<BRGallow 1500 psf=OK 18" WIDE x 24" DEEP CONTINUOUS FOOTINGS W/ #5 BARS TOP & BOTTOM (OK) CHECK MAX. ALLOWABLE POINT LOAD ON CONTINUOUS FOOTING ftgw 18 in=FOOTING WIDTH ftgd 24 in:=FOOTING DEPTH BRGallow 1500 psf=ALLOWABLE SOIL BEARING PRESSURE POST (BEARING) WIDTH:wbearing 3.5 in:= MAXIMUM POINT LOAD ALLOWABLE ON CONTINUOUS FOOTING W/O PAD FOOTING Pallow BRGallow ftgw 2ftgd wbearing+( )9656.25 lb=:= F2.) DESIGN 24" SQ. PAD FOOTING: FOOTING WIDTH:W 24 IN:= ALLOWABLE LOAD:Pallow BRGallow W26000lb=:= MAX ALLOWABLE FOR SEISMIC: W/ 1/3 INCREASE PE Pallow 4 3 8000lb=:= USE 24" SQUARE x 24" THICK PAD FOOTING W/ #5 @ 12" O.C. EACH WAY AT BOTTOM Page 8 of 11 STEEL TUBE GUARDRAIL CALCULATIONS 1a: DESIGN 4'-0" TOP RAIL FOR LATERAL LOADING 50 PLF MATERIAL PROPERTIES STEEL PIPE:USE 1 1/2" DIA. STD PIPE Fy 46 10 3× psi×:=Ab 0.75 in 2×:= Sx 0.309 in 3×:= E 29 10 6× psi×:= Ix 0.293 in 4×:= ALLOWABLE DESIGN VALUES: Fb.b 0.66 Fy×:=Fb.b 30360 psi×= Fv.b 0.4 Fy×:=Fv.b 18400 psi×= CHECK BENDING STRESSES : SPAN LENGTH:L 4 ft×:= LOADING:W 50 PLF×:=W 50 plf×= Mb W L 2× 8:=Mb 100 ft lb××= fb.b Mb Sx :=fb.b 3883.495 psi×=<Fb.b 30360 psi×=OK CHECK SHEAR DESIGN : Vb W L×:=Vb 200 lb×= fv.b Vb Ab 1.5×:=fv.b 400 psi×=<Fv.b 18400 psi×=OK USE 1 1/2" DIA. STD PIPE TOP RAIL Page 9 of 11 1b: DESIGN 42" CANTILEVERED POSTS-SUPPORTING TOP RAIL LOADING 200 LB MATERIAL PROPERTIES TUBE STEEL:USE 1 1/2" DIA. STD PIPE Fy 46 10 3× psi×:= Ab 0.75 in 2×:= Sx 0.309 in 3×:=E 29 10 6× psi×:= Ix 0.293 in 4×:= ALLOWABLE DESIGN VALUES: Fb.b 0.66 Fy×:=Fb.b 30360 psi×= Fv.b 0.4 Fy×:=Fv.b 18400 psi×= CHECK BENDING STRESSES : SPAN LENGTH:L 42 IN×:= LOADING:P 200 LB×:=P 200 lb= Mb P L×:=Mb 700 ft lb××= fb.b Mb Sx :=fb.b 27184.466 psi×=<Fb.b 30360 psi×=OK CHECK SHEAR DESIGN : Vb P:=Vb 200 lb×= fv.b Vb Ab 1.5×:=fv.b 400 psi×=<Fv.b 18400 psi×=OK USE 1 1/2" DIA. STD PIPE POST Page 10 of 11 1c: DESIGN BASE PLATE CONN. FOR POST TO BEAM: DESIGN LOADS:P 200 LB×:=DESIGN LOAD AT TOP OF POST POST HEIGHT ABV. BASE h 42 in×:= MOMENT ON COLUMN DUE TO 200 LB LOAD AT TOP OF COLUMN: Mcolumnbase P h×:=Mcolumnbase 700 ft lb××= TENSION FORCE ON BOLTS - DISTANCE FROM COLUMN EDGE TO CENTER OF BOLTS Fbolts Mcolumnbase 3.5( ) in× 1.33( )×:=Fbolts 1804.511 lb×= WELD FORCE FROM COLUMN TO BASE PLATE (WIDTH OF COLUMN) Fweld Mcolumnbase 2 in× 1.33( )×:=Fweld 3157.895 lb×= LENGTH OF WELD L 1.5 in× 1.5 in×=:= allowable fillet weld per 1/16th inch.Fw 928 lb in×:= D16 Fweld L Fw×:=D16 2.269=USE 3/16" FILLET WELD DESIGN BASEPLATE FOR BENDING DUE TO FORCE FROM BOLTS MOMENT ON THE BASEPLATE EQUAL TO THE CANTILEVERED DISTANCE FROM THE FACE OF THE COLUMN TO THE CENTER OF THE BOLT TIMES THE FORCE ON THE BOLT: M Fbolts 0.75 in×( )×:=M 112.782 FT LB××=Fy 36000 PSI×:= USE 4"x4"x3/8" b 4 in×:=t 3 8 in×:= Sx b t 2× 6:=Sx 0.094 in 3×=>Sxreq M 0.66 Fy×:=Sxreq 0.057 in 3×= DESIGN ANCHOR BOLT - ATTACHED TO WOOD FORCE ON (2) BOLT SET:Fbolts 1804.511lb= FORCE PER BOLT Fbolts 2 902.256 lb= CHECK THE WITHDRAWAL VALUE OF 3/8" DIAMETER LAG SCREW - PER NDS TABLE 11.2A Tallow = 305 PER INCH OF THREAD EMBEDMENT OF BOLTS:DEPTH Fbolts 2 305 LB IN× :=DEPTH 2.958 in×= USE 3/8" DIA.x3 1/2" EMBED LAG SCREWS Page 11 of 11