HomeMy WebLinkAbout122 California St #B - 2024 -METERGASELEC METER WWWWWWWW ELEC METER (E)200 A W WWWWWWWWWWWWWWWWWWWWWWWWW(E)SEWER LINE (E)SEWER LINE (E)6" LATERAL SEWER APPRO. 41' TO MAIN SEWER (E ) 8 " M A I N S E W E R AP P R O X . 4 1 ' T O B U I L D I N G ADU (E)200 A (E)3 GAS METERS 10'-3 1/4"31'-2"20'-0"78'-4"20'-6"30'-0" 3'- 6 " 44 ' - 1 " 2' - 5 " 9" 38 ' - 1 0 " 10 ' - 5 " 3' - 1 1 " 38 ' - 6 " 7' - 1 0 " 1.5" 122 CALIFORNIA ST. ARCADIA, CA. 91006 RESIDENTIAL ATTACHED A.D.U. DATE NO. DESCRIPTION DRAWN BY: DRAWING TITLE SCALE: SHEET NO. REVISION ACRC AS SHOWN 5120 HAMNER AVE # 140 EASTVALE, CA 91752 951.454.8801 PROJECT DATE: JUNE 2, 2024 PLAN CHECK NO. A R C ESIGN www.acrcdesigns.com These drawings, specifications, ideas, designs and arrangements represented thereby are the property of the ACRC and no part thereof shall be reproduced or used for any purpose other than the specific project for which they have been prepared, without the written consent of ACRC. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. As instruments of service, these documents are not final and ready for use, and therefore not valid unless they are sealed, signed and dated P.C. CORRECTION18/12/24 PROJECT DATA AND SITE PLAN A1.1 8,000 SQ. FT. SCOPE OF WORK: PROJECT ADDRESS: GROSS LOT AREA: 122 CALIFORNIA STREET, ARCADIA, CA. 91006 5779-002-030ASSESSOR'S ID NO: CONSTRUCTION TYPE: V-B OCCUPANCY GROUP:R-3 EXISTING LIVABLE FLOOR AREA: UNIT 1 (BLDG "A")1,020 SQ. FT. R3 - HIGH DENSITY RESIDENTIALZONING: LEGALIZING UNPERMITTED NON-LIVABLE SPACE PROPOSED ADU FLOOR AREA: TOPOGRAPHY:RELATIVELY FLAT TOTAL BUILDING COVERAGE:2,304 SQ. FT. EXISTING BUILDING HEIGHT:9'-0" LANDSCAPED AREA: 275 SQ. FT. INTO AN ATTACHED ACCESSORY DWELLING UNIT 1,850 SQ. FT.(23.2%) (28.8%) SITE MATRIX INFO: HARDSCAPED AREA / DRIVEWAY:3,846 SQ. FT.(48.0%) TOTAL LOT AREA:8,000 SQ. FT.(100.0%) PROJECT DATA MAX. FLOOR AREA RATIO ALLOWED: PROPOSED FLOOR AREA RATIO:3,248 SQ. FT. = 40.6% 3,600 SQ. FT. = 45% MAX. LOT COVERAGE ALLOWED: PROPOSED LOT COVERAGE: 4,000 SQ. FT. = 50% 2,304 SQ. FT. = 28.8% VICINITY MAP PROJECT SITE SITE PLAN SCALE: 1" = 10'-0" GOVERNING CODES SHEET INDEX ADDITIONAL PERMITS CONTRACTORS/SUBCONTRACTORS SHALL SUBMIT SEPARATE APPLICATION(S) AND SECURE SEPARATE PERMIT(S) FOR: a.ELECTRICAL WORK b.MECHANICAL WORK c.PLUMBING WORK d.DEMOLITION NOTES: 1.THE CONTRACTOR IS RESPONSIBLE FOR SCHEDULING AND SECURING FINAL TO SCHEDULING BUILDING FINAL INSPECTION: OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY INSPECTION APPROVALS FROM THE FOLLOWING DEPARTMENTS PRIOR 2.BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS 2022 CALIFORNIA BUILDING CODE - TITLE 24, PART 2 2022 CALIFORNIA RESIDENTIAL CODE - TITLE 24, PART 2 2022 CALIFORNIA ELECTRICAL CODE - TITLE 24, PART 3 2022 CALIFORNIA MECHANICAL CODE - TITLE 24, PART 4 2022 CALIFORNIA PLUMBING CODE - TITLE 24, PART 5 2022 CALIFORNIA ENERGY CODE - TITLE 24, PART 6 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE - TITLE 24, PART 11 A-1.2 RESIDENTIAL MANDATORY MEASURES A-1.1 PROJECT DATA , SITE PLAN AND GENERAL NOTES A-1.3 RESIDENTIAL MANDATORY MEASURES A-2.0 EXISTING FLOOR PLANS (FOR REFERENCE ONLY) A-2.1 PROPOSED FLOOR PLAN A-3 EXISTING EXTERIOR ELEVATIONS (FOR REFERENCE ONLY) OWNER APPLICANT PHONE: (626)372.1572 Mr. GARY LIN PROJECT TEAM PHONE: (626)429.8915 ARCADIA, CA. 91006 122 CALIFORNIA STREET MS. LINDA TSENG INSURANCE CERTIFICATE. ALL WORK SHALL CONFORM TO ALL REQUIREMENTS OF STATE OF THE WORK IS DONE IN ACCORDANCE WITH CODE REQUIREMENTS PRIOR TO REQUESTING INSPECTION. EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR ANY OTHER DRAINAGE DISPOSED OF AS SOLID WASTE. SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE STABILIZED SO AS TO INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC WAY. ACCIDENTAL DEPOSITIONS MUST BE SWEPT UP STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED MATERIALS MUST BE PROTECTED TRASH AND CONSTRUCTION RELATED SOLID WASTES MUST BE DEPOSITED INTO A COVERED FUELS, OILS, SOLVENTS AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE WITH STORAGE CONTAINERS ARE TO BE PROTECTED FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED INTO THE DRAINAGE SYSTEM. SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) SHALL BE NOTIFIED IN ACCORDANCE WORK. THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT OFFICE IS LOCATED AT A 10 DAY WAIT PERIOD PRIOR TO START OF WORK. ALL NONCOMPLIANT PLUMBING FIXTURES SHALL BE REPLACED WITH WATER-CONSERVING DUE TO THE POSSIBLE PRESENCE OF LEAD-BASED PAINT, LEAD-SAFE WORK PRACTICES ARE 17920.10 AND 105256 WITH POTENTIAL FINES FOR VIOLATIONS UP TO $5,000 (SECTION (D) AMENDED) OR IMPRISONMENT FOR NOT MORE THAN 6 MONTHS IN THE COUNTY JAIL OR BOTH. THE ISSUANCE OF A PERMIT SHALL NOT PREVENT THE BUILDING OFFICIAL FROM REQUIRING CODES ADOPTED BY THE CITY, RELEVANT LAWS, ORDINANCES, RULES AND/OR REGULATIONS. SEPARATE PERMIT SHALL FIRST BE OBTAINED FROM THE CITY PUBLIC WORKS DEPARTMENT SEPARATE PERMIT(S) ARE REQUIRED FOR DEMOLITION OF ALL STRUCTURES ON THE SITE. AT TIME OF PERMIT ISSUANCE, CONTRACTOR SHALL SHOW THEIR VALID WORKERS' COMPENSATION 1. IT IS THE RESPONSIBILITY OF THE INDIVIDUAL SUPERVISING THE CONSTRUCTION TO ENSURE THAT CALIFORNIA TITLE 24 REGARDLESS OF THE INFORMATION INDICATED ON THESE PLANS. SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTES ON SITE UNTIL THEY CAN BE AND MAY NOT BE WASHED DOWN BY RAIN OR OTHER MEANS. FROM BEING TRANSPORTED FROM THE SITE BY THE FORCES OF WIND OR WATER. RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND DISPERSAL BY WIND. THEIR LISTING AND ARE NOT TO CONTAMINATE THE SOIL AND SURFACE WATERS. ALL APPROVED 2. WITH CALIFORNIA STATE LAW PRIOR TO START OF ANY DEMOLITION, ADDITION, AND/OR REMODEL 21865 COPLEY DRIVE IN DIAMOND BAR, PHONE NO (909)396-2000 BE ADVISED, SCAQMD MAY REQUIRE 3. PLUMBING FIXTURE PRIOR TO FINAL INSPECTION. 4. REQUIRED FOR ALL REPAIRS THAT DISTURB PAINT IN PRE-1979 BUILDINGS. FAILURE TO DO SO COULD CREATE LEAD HAZARDS THAT VIOLATE CALIFORNIA HEALTH & SAFETY CODE, SECTIONS 5. THE CORRECTION OF ERRORS ON THESE PLANS OR FROM PREVENTING ANY VIOLATION OF THE 6. PRIOR TO PLACEMENT OF ANY CONSTRUCTION MATERIALS OR EQUIPMENT IN THE PUBLIC WAY. 7. GENERAL NOTES EMAIL: GBL@ARCHTURAE.COM CITY OF ARCADIA MUNICIPAL CODE FIRE SPRINKLER SYSTEM:NONE (EXISTING RESIDENCE) FIRE SPRINKLER SYSTEM:NOT REQUIRED FOR ADU UNIT 2 (BLDG "A")757 SQ. FT. UNIT 3 (2nd FLR - BLDG "B")598 SQ. FT. UNIT 4 (2nd FLR - BLDG "B")598 SQ. FT. GARAGE #1 (BLDG "A")380 SQ. FT. CARPORT #2 (BLDG "B")453 SQ. FT. CARPORT #3 (BLDG "B")598 SQ. FT. CARPORT #4 (BLDG "B")598 SQ. FT. TOTAL EXISTING FLOOR AREA 3,248 SQ. FT. UNPERMITTED AREA (BLDG "B)275 SQ. FT. EXISTING NON-LIVABLE FLOOR AREA: CA L I F O R N I A S T R E E T CL AL L E Y PROPERTY LINE 160' PROPERTY LINE 160' PR O P E R T Y L I N E 5 0 ' PR O P E R T Y L I N E 5 0 ' 118 CALIFORNIA STREET ADJACENT PROPERTY 126 CALIFORNIA STREET ADJACENT PROPERTY 122 CALIFORNIA STREET (E) 1-STORY RESIDENCE (E) GARAGE #1 (E) CARPORT #2 (E) CARPORT #3 (E) CARPORT #4 (E) LANDSCAPE AREA TO REMAIN (E) LANDSCAPE AREA TO REMAIN (E) LANDSCAPE AREA (E) SLOPE 5% (E) SLOPE 2% (E) SLOPE 2% (E) SLOPE 5% (E) ENTRY (E) ENTRY (E) CMU FENCE WALL TO REMAIN (E) CMU FENCE WALL TO REMAIN (E) GAS METER (E) ELECTRICAL METER (E) WATER METER (E) DRIVEWAY TO REMAIN (E) DRIVEWAY TO REMAIN SCOPE OF WORK: LEGALIZING UNPERMITTED NON-LIVABLE SPACE INTO AN ATTACHED ACCESSORY DWELLING UNIT NOTES: THIS PROJECT IS NOT LOCATED WITHIN VERY HIGH FIRE HAZARD SEVERITY ZONES (VHFHSZ) ARCHITECTURAL EASTVALE, CA 91752 5120 HAMNER AVE, #140 ACRC DESIGN GROUP CONTACT: HENRY CHEN PHONE: (951) 454.8801 1 1 1 1 (E) CONC WALKWAY TO REMAIN (E) 1 HR RATED EXTERIOR WALL TO REMAIN, SEE DETAIL #4,5 & 6 / A4 (E) 1 HR RATED INTERIOR WALL TO REMAIN, SEE DETAIL #4 / A4 1 1 1 CONDENSER UNIT LOCATION ON A 3" PREFABRICATED OR CONCRETE PAD (BLDG "A")UNIT '1'UNIT '2' EXISTING BLDG "A" TOTAL AREA 1,777 SQ. FT. EXISTING BLDG "B" TOTAL AREA 1,471 SQ. FT. (BLDG "B") 1 ENERGY REPORT - T24 SAN GABRIEL, CA. 91775 1217 E. LAS TUNAS DRIVE TRICOLOR ENGINEERING CONTACT: YONGHUI CHEN PHONE: (626) 692.1221 STRUCTURAL ONTARIO, CA 91761 3954 E ATTALLA STREET PETER CHAO & ASSOCIATES CONTACT: PETER CHAO PHONE: (909) 680.2727 A-4 ARCHITECTURAL DETAILS AND SECTION T-1 ENERGY ANALYSIS REPORT (T-24) T-2 ENERGY ANALYSIS REPORT (T-24) T-3 ENERGY ANALYSIS REPORT (T-24) S-1 STRUCTURAL DETAILS S-2 STRUCTURAL DETAILS S-3 FOUNDATION PLAN S-4 FLOOR FRAMING PLA 8/14/2024 7:50:50 PM 122 CALIFORNIA ST. ARCADIA, CA. 91006 RESIDENTIAL ATTACHED A.D.U. DATE NO. DESCRIPTION DRAWN BY: DRAWING TITLE SCALE: SHEET NO. REVISION ACRC AS SHOWN 5120 HAMNER AVE # 140 EASTVALE, CA 91752 951.454.8801 PROJECT DATE: JUNE 2, 2024 PLAN CHECK NO. A R C ESIGN www.acrcdesigns.com These drawings, specifications, ideas, designs and arrangements represented thereby are the property of the ACRC and no part thereof shall be reproduced or used for any purpose other than the specific project for which they have been prepared, without the written consent of ACRC. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. As instruments of service, these documents are not final and ready for use, and therefore not valid unless they are sealed, signed and dated P.C. CORRECTION18/12/24 A1.2 RESIDENTIAL MANDATORY MEASURES 8/14/2024 7:51:09 PM 122 CALIFORNIA ST. ARCADIA, CA. 91006 RESIDENTIAL ATTACHED A.D.U. DATE NO. DESCRIPTION DRAWN BY: DRAWING TITLE SCALE: SHEET NO. REVISION ACRC AS SHOWN 5120 HAMNER AVE # 140 EASTVALE, CA 91752 951.454.8801 PROJECT DATE: JUNE 2, 2024 PLAN CHECK NO. A R C ESIGN www.acrcdesigns.com These drawings, specifications, ideas, designs and arrangements represented thereby are the property of the ACRC and no part thereof shall be reproduced or used for any purpose other than the specific project for which they have been prepared, without the written consent of ACRC. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. As instruments of service, these documents are not final and ready for use, and therefore not valid unless they are sealed, signed and dated P.C. CORRECTION18/12/24 A1.3 RESIDENTIAL MANDATORY MEASURES 8/14/2024 7:51:28 PM METERGASELEC METER WWWWWWWW ELEC METER (E)200 A W W WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW (E)SEWER LINE (E)SEWER LINE (E)6" LATERAL SEWER APPRO. 41' TO MAIN SEWER ADU (E)200 A (E)3 GAS METERS (E)31'-2" (E ) 2 7 ' - 1 " (E ) 2 1 ' - 1 0 3 / 4 " (E ) 1 1 ' - 0 1 / 2 " (E ) 1 1 ' - 1 3 / 4 " (E ) 4 4 ' - 1 " (E)22'-2"(E)4'-6 1/2" (E)9'-0" (E)18'-3"(E)23'-9"(E)14'-4"(E)22'-0" (E)78'-4" (E ) 1 2 ' - 3 " (E ) 1 4 ' - 4 1 / 2 " (E ) 1 1 ' - 1 0 1 / 2 " (E ) 3 8 ' - 6 " (E ) 3 8 ' - 1 0 " (E)42'-0"(E)27'-1 1/2"(E)9'-2 1/2" (E)78'-4" (E ) 6 ' - 9 " (E ) 2 0 ' - 9 1 / 2 " (E ) 1 3 ' - 8 1 / 2 " (E ) 3 ' - 6 " (E)27'-2" (E ) 4 4 ' - 1 " (E)27'-2" 122 CALIFORNIA ST. ARCADIA, CA. 91006 RESIDENTIAL ATTACHED A.D.U. DATE NO. DESCRIPTION DRAWN BY: DRAWING TITLE SCALE: SHEET NO. REVISION ACRC AS SHOWN 5120 HAMNER AVE # 140 EASTVALE, CA 91752 951.454.8801 PROJECT DATE: JUNE 2, 2024 PLAN CHECK NO. A R C ESIGN www.acrcdesigns.com These drawings, specifications, ideas, designs and arrangements represented thereby are the property of the ACRC and no part thereof shall be reproduced or used for any purpose other than the specific project for which they have been prepared, without the written consent of ACRC. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. As instruments of service, these documents are not final and ready for use, and therefore not valid unless they are sealed, signed and dated P.C. CORRECTION18/12/24 EXISTING FLOOR PLANS (REFERENCE ONLY) A2.0 LEGEND: EXISTING WALLS TO REMAIN UNIT 1 FLOOR PLAN SCALE: 3/16" = 1'-0" NO R T H UNIT 3 & 4 FIRST FLOOR PLAN SCALE: 3/16" = 1'-0" (E)LIVING ROOM (E)BEDROOM 2 (E)BEDROOM 1 (E)KITCHEN (E)KITCHEN (E)BEDROOM 1(E)BEDROOM 2 (E)BATH (E)BATH1(E)BATH2 (E)GREAT ROOM (E)BATH (E)BEDROOM (E)GREAT ROOM (E)KITCHEN (E)BATH (E)BEDROOM 1 (E)BEDROOM 2 (E)GREAT ROOM (E)KITCHEN (E)BATH (E)BEDROOM 2 (E)BEDROOM 1 UNIT 2 FLOOR PLAN SCALE: 3/16" = 1'-0" UNIT 3 & 4 FIRST SEOND PLAN SCALE: 3/16" = 1'-0" (E)GARAGE #1 2 SPACES(E)CARPORT #2 2 SPACES (E)CARPORT #3 1 SPACE (E)CARPORT #4 1 SPACE (E)UNIT 1 ENTRY(E)UNIT 2 ENTRY (E)UNIT 3 ENTRY (E)UNIT 4 ENTRY LEGALIZING UNPERMITTED NON-LIVABLE SPACE INTO ACCESSORY DWELLING UNIT - REFER TO SHEET A2.1 8/14/2024 8:30:00 PM REFR (E)31'-2" (E ) 2 7 ' - 1 " (E ) 4 4 ' - 1 " (E)22'-2"(E)4'-6 1/2" (E)9'-0" 3' - 4 " 3' - 2 " 6'- 6 " 8'-6" GFCI SVGFCIS SD CO SD 9'- 0 " 6'- 6 " 9'- 9 1 / 2 " 8'-8"2'-0"18'-5" 21'-0 1/2" 21 ' - 3 " 10 ' - 5 " 10 ' - 5 " GFCI TEMP GLASS AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI GFCI AFCI WP DOOR TYPE DOOR SCHEDULE WD SIZE NO 1 WIDTH HEIGHT LOCATION TYPE MATERIAL DOOR PTD FINISH FRAME a SEE SCHED 6' - 8 " HCaBEDROOM 2'-6" F.F. 6'-8"SWING CEILING MOUNTED HIGH EFFICACY RECESS LIGHT FIXTURE WALL ELECTRICAL OUTLET S GFCI LIGHT SWITCH INTERIOR WALL MOUNTED LIGHT FIXTURE S SV WALL ELECTRICAL OUTLET PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER VACANCY SENSOR SWITCH FOR BATHROOM & EXTERIOR LIGHT FIXTURE SWITCH TO BE MANUALLY ON/OFF SWITCH CONTROLLED, AND HAVE BOTH MOTION SENSOR AND PHOTOCELL CONTROL. MATERIAL ELECTRICAL LEGEND EXHAUST FAN: MINIMUM 50 CFM TO BE DUCTED TO THE EXTERIOR AND SHALL PROVIDE FIVE AIR CHANGES PER HOUR; SECTION 1203.3. CFM AND NOISE RATING MAX. 3 SONE FOR INTERMITTENT USE. SHALL BE ENERGY STAR RATED AND CONTROLLED BY A HUMIDISTAT CAPABLE OF AN ADJUSTMENT BETWEEN 50~80% HUMIDITY DUCT SYSTEMS ARE SIZED, DESIGNED AND EQUIPMENT IS SELECTED USING THE FOLLOWING METHODS: 1. ESTABLISH HEAT LOSS & HEAT GAIN VALUES ACCORDING TO ANSI / ACCA 2 MANUAL J-2011 OR EQUIVALENT 2. SIZE DUCT SYSTEMS ACCORDING TO ANSI/ ACCA I MANUEL D-2014 OR EQUIVALENT. 3. SELECT HEATING & COOLING EQUIPMENT ACCORDING TO ANSI/ ACCA 3 MANUAL S-2014 OR EQUIVALENT. 4. EXHAUST OUTLET MUST BE MINIMUM 3'-0" FROM ANY OPENING INTO BUILDING AND 3'-0" FROM THE PROPERTY LINE. CO EXISTING CM CARBON MONOXIDE ALARM PERMANENTLY WIRED WITH BATTERY BACKUP PER SECTION R315. ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE UNIT. SD EXISTING SMOKE DETECTORS PER SECTION R314 DETECTORS SHALL BE PERMANENTLY WIRED WITH BATTERY BACKUP. SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREAS. ALARM DEVICES SHALL BE INTERONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE UNIT. SHALL COMPLY WITH THE FOLLOWING: a.AT LEAST 3' FROM THE TIP OF THE BLADE OF A CEILING-MOUNTED FAN b.NOT LESS THAN 3' FROM THE DOOR OPENING OF A BATHROOM c.AT LEAS 20' FROM A COOKING APPLIANCE OR 10' FROM COOKING APPLIANCE WHEN THE ALARM IS AN IONIZING SMOKE ALARM PER NFPA 72 SECTION 29.8.3.4 ITEM 4 d.AT LEAST 3' FROM SUPPLY REGISTERS OF A HEATING / COOLING SYSTEM WD2 PTDSCaENTRANCE3'-0"6'-8"SWING A WINDOW TYPE FIN. FLR. WINDOW SCHEDULE MATERIAL SIZE SYMB WIDTH HEIGHT THKNS. LOCATION TYPE WINDOW FRAME FINISH GLAZING A MATERIALTYPEGLASSTHKNS. REGULATIONS, WHERE WINDOW IS WITHIN 12" OF A DOOR, AND JAMB, AND SILL DETAILS. APPROVED FLASHING. INSTITUTE STANDARDS. COMPLIANCE WITH AMERICAN NATIONAL STANDARD 6. WINDOWS SHALL BE CERTIFIED AND LABELED IN 5. FLASH AROUND ALL EXTERIOR WINDOW OPENINGS WITH 11. ALL WINDOWS TO HAVE INSECT SCREENS AT SLIDING 12. WINDOWS AND FRAMES COLOR AND FINISH PER OWNER PANEL LOCATION. WINDOW NOTES 2019 CBC, CHAPTER 24, AND 16 CFR 1201 WINDOW OPENING AND FIELD ROUGH DIMENSIONS. MATERIALS. SAFETY STANDARDS FOR ARCHITECTURAL GLAZING 3. ALL ALUMINUM SASH TO COMPLY WITH THE AAMA STANDARDS. 4. T INDICATES GLASS TO BE TEMPERED PER ABOVE MENTIONED 9. ALL WINDOW FRAMES TO BE PAINTED WITH SILICONE DRAWINGS TO INCLUDE (BUT NOT LIMITED TO) HEAD, DETAILED SHOP DRAWINGS PRIOR TO FABRICATION. 10. WINDOW CONTRACTOR TO PROVIDE ARCHITECT WITH POLYESTER COATING, COLOR BY ARCHITECT. 1. ALL WINDOW ELEVATIONS BELOW WERE DRAWN AS VIEWED 2. ALL GLASS AND GLAZING TO BE IN ACCORDANCE WITH THE 8. FRAMING CONTRACTOR TO VERIFY MANUFACTURER'S ROUGH ALUMINUM. 7. UNLESS OTHERWISE NOTED, ALL WINDOWS FRAMES TO BE FROM EXTERIOR SIDE AT A SCALE OF 3/16" = 1'-0". IN DOORS AND ENCLOSURE FOR HOT TUB, BATHTUB, SHOWERS (ALSO GLAZING IN WALL ENCLOSING THESE COMPARTMENTS WITHIN 5' OF STANDING SURFACE) B B 2'-0"3'-0" BEDROOM & GREAT ROOM VENTILATION AREA: 7.3 SQ. FT. VINYL4'-0"3'-0" BATHROOM PTD GLDBL GLAZED CLEAR3/8"(E)SLIDING U-FACTOR SHGC FACTOR 0.3 NFRC 0.23 NFRC 4' - 0 " 2' - 8 " 4'-0" (E)SLIDING VINYL PTD GLDBL GLAZED CLEAR3/8"0.3 NFRC 0.23 NFRC 3' - 0 " 3' - 8 " 2'-0" 122 CALIFORNIA ST. ARCADIA, CA. 91006 RESIDENTIAL ATTACHED A.D.U. DATE NO. DESCRIPTION DRAWN BY: DRAWING TITLE SCALE: SHEET NO. REVISION ACRC AS SHOWN 5120 HAMNER AVE # 140 EASTVALE, CA 91752 951.454.8801 PROJECT DATE: JUNE 2, 2024 PLAN CHECK NO. A R C ESIGN www.acrcdesigns.com These drawings, specifications, ideas, designs and arrangements represented thereby are the property of the ACRC and no part thereof shall be reproduced or used for any purpose other than the specific project for which they have been prepared, without the written consent of ACRC. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. As instruments of service, these documents are not final and ready for use, and therefore not valid unless they are sealed, signed and dated P.C. CORRECTION18/12/24 ACCESSORY DWELLING UNIT FLOOR PLAN A2.1 ELECTRICAL & PLUMBING NOTES: ENERGY LIGHTING NOTE: CEILING: WALL: BASE: FLOOR: FINISH NOTES: FLOOR PLAN NOTES: LEGEND: 1 NEW DOOR NUMBER EXISTING WALLS TO REMAIN AND REPAIR BATHROOMS: CERAMIC TILE BATHROOMS: CERAMIC TILE BATHROOMS: GYPSUM BOARD WITH TWO COATS SEMI-GLOSS ENAMEL PAINT WITH KNOCKDOWN TEXTURE BATHROOMS: GYPSUM BOARD WITH TWO COATS FLAT LATEX PAINT WITH KNOCKDOWN TEXTURE 1.WATER CONSERVING FIXTURES: NEW WATER CLOSETS SHALL USE NO MORE THAN 1.28 GALLONS OF WATER PER FLUSH, LAVATORIES MAY NOT EXCEED 1.2 GPM, KITCHEN FAUCETS MAY NOT EXCEED 1.8 GPM, AND SHOWERS MAY NOT EXCEED 1.8 GPM OF FLOW. 2.WALL COVERING SHALL BE CEMENT PLASTER, TILE OR APPROVED EQUAL TO 72" ABOVE DRAIN AT SHOWERS OR TUB WITH SHOWERS. MATERIALS OTHER THAN STRUCTURAL ELEMENTS ARE TO BE MOISTURE RESISTANT. 3.SURROUND AROUND THE SHOWER MUST BE TEMPERED. GLAZING IN THE WALLS/DOORS FACING OR CONTAINING BATHTUBS OR SHOWERS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE THE STANDING SURFACE. EXCEPTION: GLAZING THAT IS MORE THAN 60", MEASURED HORIZONTALLY, FROM THE WATER'S EDGE OF A BATHTUB. 4.PROVIDE A MINIMUM 72 INCH HIGH NON-ABSORBENT SURFACE AT SHOWER AND TUB AREA. 5.PROVIDE TEMPERED GLASS SHOWER ENCLOSURE - MIN. 1,024 SQ. IN. AREA AND 30" DIAMETER IN SHOWER COMPARTMENT. 6.PROVIDE A MINIMUM OF 24 INCHES CLEAR IN FRONT OF WATER CLOSET, AND A MINIMUM COMPARTMENT WIDTH OF 30 INCHES. 7. CEMENT, FIBER-CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT GYPSUM OR FIBER-REINFORCED GYPSUM BACKERS SHALL BE USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN SHOWER AREAS (CRC 702.4.2) E EXISTING DOOR TO REMAIN NEW INTERIOR WALL 2 x STUDS @ 16"O.C. WITH 1/2" REGULAR GYPSUM WALLBOARDS ON BOTH SIDES NOTE: USE WATER RESISTANT GYPSUM BOARD IN LIEU OF SPECIFIED WALLBOARD 1.PLUMBING WALL SHALL BE A MINIMUM OF 2x6 CONSTRUCTION. 2.TWO LAYERS OF GRADE D PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING. 3.PROVIDE A WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE A MIN. 4" ABOVE THE EARTH OR 2" ABOVE PAVED AREAS. 4.NO SOUNDPROOFING WORK SHALL BE COVERED BEFORE A SPECIAL SOUNDPROOFING INSPECTION IS OBTAINED FROM THE BUILDING AND SAFETY DIVISION. 5.ALL VOIDS AROUND PLUMBING PIPES SHALL BE PACKED WITH ROCK WOOL OR EQUIVALENT SOUND DEADENING MATERIAL APPROVED BY THE BUILDING OFFICIAL AND ALL PLUMBING PIPES SHALL BE WRAPPED AT ALL POINTS OF CONTACT WITH ANY WOOD OR STEEL MEMBERS AND STRAP HANGARS. 6.ALL CABLES, WIRES, CONDUIT SYSTEMS AND PIPING OUTSIDE BUILDINGS OR STRUCTURES AND WITHIN THE EXTERIOR PROPERTY LINES SHALL BE INSTALLED UNDERGROUND OTHER THAN RISERS IMMEDIATELY ADJACENT AND ATTACHED TO THE BUILDING. 7.AT LEAST ONE DUPLEX OUTLET AND A MINIMUM OF ONE CEILING LIGHT FIXTURE PROVIDING AT LEAST ONE FOOT-CANDLE (10.76 LUX) AT GROUND LEVEL, SHALL BE PROVIDED FOR EVERY 400 SQUARE FEET OF COVERED PARKING AREA, ALL STEPS, RAMPS, DRIVEWAYS OR CORRIDORS LEADING TO COVERED PARKING AREAS SHALL BE ILLUMINATED TO AN INTENSITY OF 1 FOOT-CANDLE (10.76 LUX) AT GROUND LEVEL. 8.THE BUILDING SHALL HAVE WATER CLOSETS (TOILETS) WHICH USE NO MORE THAN 1.28 GALLONS PER FLUSH. 9.CONTROL VALVES FOR ALL SHOWERS AND TUB-SHOWERS SHALL HAVE EITHER A PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE. 10.THE CENTER OF 15-,20- AND 30-AMPERE RECEPTACLE SHALL BE INSTALLED NOT LESS THAN 12 INCHES ABOVE THE FLOOR OR WORKING SURFACE. 11.IN A CLOSET SURFACE MOUNTED LIGHT FIXTURES SHALL BE AT LEAST 12 INCHES FROM A STORAGE AREA AND FLUSH MOUNTED LIGHTING FIXTURES SHALL BE AT LEAST 6 INCHES FROM A STORAGE AREA. 12.GROUND-FAULT CIRCUIT-INTERRUPTER (GFI) PROTECTED ELECTRICAL RECEPTACLES SHALL BE PROVIDED AT ALL RECEPTACLES: A) INSTALLED IN A BATHROOM B) INSTALLED IN A GARAGE C)OUTDOOR D) WITHIN 6 FT. OF A KITCHEN SINK 13.ELECTRICAL RECEPTACLES INSTALLED OUTDOORS WHERE EXPOSED TO WEATHER SHALL BE IN A WEATHERPROOF ENCLOSURE. 14.LOCATION FOR ALL NEW ELECTRICAL SERVICES SHALL BE REQUIRED BY THE DESIGN CO. 15.SMOKE DETECTORS MUST RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY BACKUP AND INTERCONNECTED. 1.ALL INSTALLED LUMINARIES SHALL BE HIGH-EFFICACY IN ACCORDANCE WITH ES TABLE 150.0-A a) LUMINARIES MUST HAVE A LABEL CERTIFIED FOR AIRTIGHT CONSTRUCTION. b) LIGHT SOURCES THAT ARE NOT MARKED "JA8-2019-E" SHALL NOT BE INSTALLED IN ENCLOSED LUMINAIRES. ES 150.0(k) 2.DIMMERS OR VACANCY SENSORS SHALL CONTROL ALL LED STYLE LUMINARIES. TWO EXCEPTIONS: FIXTURES INSTALLED IN HALLWAYS OR CLOSETS UNDER 70 S.F. 3.RECESSED CAN LIGHT FIXTURES SHALL BE IC LISTED, AIR-TIGHT LABELED, AND NOT TO BE EQUIPPED WITH A STANDARD MEDIUM BASE SCREW SHELL LAMP HOLDER. ES 150.0)k) NO R T H ACCESSORY DWELLING UNIT FLOOR PLAN SCALE: 3/16" = 1'-0" (E)BEDROOM TO REMAIN (78 S.F.)(E ) C L O S E T TO R E M A I N (E)GREAT ROOM TO REMAIN (E)BATH TO REMAIN 1 2 (E)4'-0"Wx4'-0'H WINDOW TO REMAIN (E)2'-0"Wx4'-0'H WINDOW TO REMAIN (E)4'-0"Wx4'-0'H WINDOW TO REMAIN EXISTING TO BE REMOVED WATER HEATER SEE T-24 FOR SPECIFICATIONS EXISTING ONE HOUR RATED WALL - SEE DETAIL #4/A4 (E) 2-CARPORT TO REMAIN (E) 1-CARPORT TO REMAIN (E) 1-CARPORT TO REMAIN (E) 1 HR RATED EXTERIOR WALL TO REMAIN, SEE DETAIL #4,5 & 6 / A4 (E) 1 HR RATED INTERIOR WALL TO REMAIN, SEE DETAIL #4 / A4 1 1 A EXISTING WINDOW TO REMAIN A A B 1 1 2 THE KITCHEN EXHAUST HOOD (LOCAL EXHAUST VENTILATION). A MINIMUM RATE OF 100 CFM IS REQUIRED, A MAXIMUM SOUND RATING OR 3 SONE FOR INTERMITTENT OPERATION IS REQUIRED. THE KITCHEN HOOD DUCTED TO OUTSIDE AIR IS REQUIRED REGARDLESS OF THE FUEL TYPE OR HOOD TYPE (MICROWAVE HOOD). 208/230V ULTRA HEAT SINGLE ZONE DUCTLESS MINI-SPLIT HEAT PUMP SYSTEM. (OR BETTER) MANUFACTURER: BLUERIDGE MODEL: BMKH1231 12,000 BTU (1 TON) 30.5 SEER / 24 SEER2 - S5 SERIES FLOOR KEYNOTES: 1 2 8/14/2024 8:31:38 PM F.G. (E ) 9 ' - 0 " (E ) 1 7 ' - 0 " (E ) 8 ' - 0 " (E)2ND FF (E)T.O.P. (E ) 2 4 ' - 2 " (E)T.O.R. F.G. (E ) 9 ' - 0 " (E ) 1 7 ' - 0 " (E ) 8 ' - 0 " (E)2ND FF (E)T.O.P. (E ) 2 4 ' - 2 " (E)T.O.R. F.G. (E ) 9 ' - 0 " (E ) 1 7 ' - 0 " (E ) 8 ' - 0 " (E)2ND FF (E)T.O.P. (E ) 2 4 ' - 2 " (E)T.O.R. F.G. (E ) 9 ' - 0 " (E ) 1 7 ' - 0 " (E ) 8 ' - 0 " (E)2ND FF (E)T.O.P. (E ) 2 4 ' - 2 " (E)T.O.R. F.G. (E ) 8 ' - 0 " (E)T.O.P. 122 CALIFORNIA ST. ARCADIA, CA. 91006 RESIDENTIAL ATTACHED A.D.U. DATE NO. DESCRIPTION DRAWN BY: DRAWING TITLE SCALE: SHEET NO. REVISION ACRC AS SHOWN 5120 HAMNER AVE # 140 EASTVALE, CA 91752 951.454.8801 PROJECT DATE: JUNE 2, 2024 PLAN CHECK NO. A R C ESIGN www.acrcdesigns.com These drawings, specifications, ideas, designs and arrangements represented thereby are the property of the ACRC and no part thereof shall be reproduced or used for any purpose other than the specific project for which they have been prepared, without the written consent of ACRC. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. As instruments of service, these documents are not final and ready for use, and therefore not valid unless they are sealed, signed and dated P.C. CORRECTION18/12/24 EXISTING EXTERIOR ELEVATIONS (REFERENCE ONLY) A3 ACCESSORY DWELLING UNIT NORTH ELEVATION SCALE: 3/16" = 1'-0" ACCESSORY DWELLING UNIT EAST ELEVATION SCALE: 3/16" = 1'-0" ACCESSORY DWELLING UNIT WEST ELEVATION SCALE: 3/16" = 1'-0" ACCESSORY DWELLING UNIT SOUTH ELEVATION SCALE: 3/16" = 1'-0" EXISTING EXTERIOR ELEVATIONS NOTE: EXISTING FINISHED MATERIAL, WINDOWS, DOORS, ROOF TILES, STAIR AND GUARDRAIL TO REMAIN AS IS, NO ALTERATION EXISTING STUCCO FINISH TO REMAIN EXISTING STUCCO FINISH TO REMAIN EXISTING STUCCO FINISH TO REMAIN EXISTING STUCCO FINISH TO REMAIN 8/14/2024 8:32:24 PM 122 CALIFORNIA ST. ARCADIA, CA. 91006 RESIDENTIAL ATTACHED A.D.U. DATE NO. DESCRIPTION DRAWN BY: DRAWING TITLE SCALE: SHEET NO. REVISION ACRC AS SHOWN 5120 HAMNER AVE # 140 EASTVALE, CA 91752 951.454.8801 PROJECT DATE: JUNE 2, 2024 PLAN CHECK NO. A R C ESIGN www.acrcdesigns.com These drawings, specifications, ideas, designs and arrangements represented thereby are the property of the ACRC and no part thereof shall be reproduced or used for any purpose other than the specific project for which they have been prepared, without the written consent of ACRC. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. As instruments of service, these documents are not final and ready for use, and therefore not valid unless they are sealed, signed and dated P.C. CORRECTION18/12/24 DETAILS A4INTERIOR SURFACE TREATMENT AS REQUIRED PER IBC 2012 TABLE 721.1 (2) ITEM 12 OR 14 MIN. 2X4 STUDS AT 16" O.C., SEE STRUCTURAL DRAWINGS OPTIONAL GLASS FIBER BATT INSULATION PER THERMAL REQUIREMENTS 7/8" EXTERIOR CEMENT PLASTER METAL LATH OVER 1 LAYER OF WEATHER RESISTIVE BARRIER WOOD STRUCTURAL SHEAR PANEL WHERE OCCURS, SEE STRUCTURAL DO O R W I D T H 5/8"5/8" 1 15/16"1 9/16" 1 916 "1 34" 1/ 2 " GYP. BOARD, TYP SEE FINISH SCHEDULEWOOD DOOR & FRAME BY CONTRACTOR 2 x WD. STUDS AT 16" O.C. BATT / SOUND INSULATION AS OCCURS DOOR, SEE DOOR SCHEDULE. NOTE: REFER TO SCHEDULE FOR DOOR SIZES. SEE SCHED. FLOOR FIN. ALUM. THRESHOLD 1 1/2" DOOR SEE DOOR SCHED. INTERIOR DOOR HEAD SCALE: N.T.S.1 INTERIOR DOOR THRESHOLD SCALE: N.T.S.3 DOOR DIMENSION 5/8 GYPSUM BOARD 2" 5/8"12" SHIM PEMKO S88D SILICONSEAL WD DOOR, FRAME, TRIM & WEATHER STRIP BY MFR 1 1/2" DOOR SEE DOOR SCHED. BATT / SOUND INSULATION AS OCCURS INTERIOR DOOR JAMB SCALE: N.T.S.2 1 HOUR EXTERIOR WALL SCALE: N.T.S.4 (E) FASTENERS (E)PLYWOOD SHEATHING, GALVANIZED WEEP SCREED, CORRESION RESISTANT MATERIAL 5/8" TYPE 'X' GYP. BD. INSULATION (E)FINISH FLOOR, 2" MI N . 4" MI N . (E)FINISH GRADE (E)7/8" CEMENT PLASTER ON METAL LATH OVER 2 LAYERS OF GRADE D BUILDING PAPER BASE AT EXTERIOR WALL SCALE: N.T.S.5 TERMINATION SCREED, MIN 0.019" CORROSION RESISTANT. SHALL BE PLACED MIN OF 4" ABOVE EARTH, OR 2" ABOVE PAVED/ SIDEWALK AREAS THREE COAT CEMENT PLASTER OVER METAL LATH OVER (2) LAYERS WATER RESISTANT BARRIER OVER SHEATHING 20 GA. CORROSION RESISTANT FLASHING PAINTED TO MATCH ADJACENT FINISH. SHALL BE PLACED MIN. OF 3" ABOVE TERMINATION SCREED AND MIN. OF 3" BELOW FINISH EXT. GRADE SILL GASKET CONT. BEAD OF SEALANT FRAMING MEMBER BATT INSULATION PER T-24 5/8" GYPSUM BOARD @ INTERIOR FLASHING AT EXTERIOR WALL SCALE: N.T.S.6 4 A4 EXISTING ROOF AND FRAMING TO REMAIN PROVIDE MIN. R-30 INSULATION EXISTING 1 HOUR RATED EXTERIOR WALL TO REMAIN, PROVIDE TYPE 'X' GYP BOARD AT INTERIOR SIDE PROVIDE MIN. R-15 INSULATION (DAMAGED TO BE REPAIR WHERE OCCURS) EXISTING EXTERIOR WALL FLASHING & BASE 5&6 A4 EXISTING 1 HOUR RATED INTERIOR WALL TO REMAIN BETWEEN PARKING GARAGE AND ADU, PROVIDE TYPE 'X' GYP BOARD AT GARAGE SIDE PROVIDE MIN. R-15 INSULATION (DAMAGED TO BE REPAIR WHERE OCCURS) 4 A4 EXTERIORINTERIOR BUILDING SECTION SCALE: 1/2" = 1'-0"A 8/14/2024 8:34:26 PM 122 CALIFORNIA ST. ARCADIA, CA. 91006 RESIDENTIAL ATTACHED A.D.U. DATE NO. DESCRIPTION DRAWN BY: DRAWING TITLE SCALE: SHEET NO. REVISION ACRC AS SHOWN 5120 HAMNER AVE # 140 EASTVALE, CA 91752 951.454.8801 PROJECT DATE: JUNE 2, 2024 PLAN CHECK NO. A R C ESIGN www.acrcdesigns.com These drawings, specifications, ideas, designs and arrangements represented thereby are the property of the ACRC and no part thereof shall be reproduced or used for any purpose other than the specific project for which they have been prepared, without the written consent of ACRC. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. As instruments of service, these documents are not final and ready for use, and therefore not valid unless they are sealed, signed and dated P.C. CORRECTION18/12/24 ENERGY ANALYSIS REPORT T1 8/14/2024 8:34:48 PM 122 CALIFORNIA ST. ARCADIA, CA. 91006 RESIDENTIAL ATTACHED A.D.U. DATE NO. DESCRIPTION DRAWN BY: DRAWING TITLE SCALE: SHEET NO. REVISION ACRC AS SHOWN 5120 HAMNER AVE # 140 EASTVALE, CA 91752 951.454.8801 PROJECT DATE: JUNE 2, 2024 PLAN CHECK NO. A R C ESIGN www.acrcdesigns.com These drawings, specifications, ideas, designs and arrangements represented thereby are the property of the ACRC and no part thereof shall be reproduced or used for any purpose other than the specific project for which they have been prepared, without the written consent of ACRC. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. As instruments of service, these documents are not final and ready for use, and therefore not valid unless they are sealed, signed and dated P.C. CORRECTION18/12/24 ENERGY ANALYSIS REPORT T2 8/14/2024 8:35:10 PM 122 CALIFORNIA ST. ARCADIA, CA. 91006 RESIDENTIAL ATTACHED A.D.U. DATE NO. DESCRIPTION DRAWN BY: DRAWING TITLE SCALE: SHEET NO. REVISION ACRC AS SHOWN 5120 HAMNER AVE # 140 EASTVALE, CA 91752 951.454.8801 PROJECT DATE: JUNE 2, 2024 PLAN CHECK NO. A R C ESIGN www.acrcdesigns.com These drawings, specifications, ideas, designs and arrangements represented thereby are the property of the ACRC and no part thereof shall be reproduced or used for any purpose other than the specific project for which they have been prepared, without the written consent of ACRC. Visual contact with these drawings or specifications shall constitute conclusive evidence of acceptance of these restrictions. As instruments of service, these documents are not final and ready for use, and therefore not valid unless they are sealed, signed and dated P.C. CORRECTION18/12/24 ENERGY ANALYSIS REPORT T3 8/14/2024 8:35:33 PM ROOF SHEATHING 2X R.R. 6-16d COMM. NAILS B.N. B.N. 2X FACIAL BOARD 2X C.J. PER PLAN 2X STUD WALL SIMPSON A35 @ 16" O.C. B.N. T & G BOARD 2-2X TOP PLATE ROOF SHEATHING 2X R.R. 6-16d COMM. NAILS B.N. 2X FACIAL BOARD 2X C.J. PER PLAN 2X STUD WALL SIMPSON A35 @ 16" O.C. B.N. T & G BOARD 2-2X TOP PLATE 2X RAFTER TIE @ EA. RATER A B DROP BEAMWHERE OCCUR DROP BEAMWHERE OCCUR B.N. DOUBLE SIDE SHEAR WALL WHERE OCCUR 3" 1-#4 VERTICAL REBAR @ EA. CORNER POST SEE PLAN COLUMN BASE SEE PLAN PAD A SEE PLAN PAD REBAR SEE PLAN WHERE OCCUR 2X OR 3X P.T. SILL PLATE (E) R.R (E) ROOF SHEATHING B.N. (N) ROOF SHEATHING PER PLAN (N) 2X R.R. PER PLAN (N) 2X BLOCKING 6 2X4 STUD WALL 2-2X TOP PLATE ROOF SHEATHING 2-2X ROOF RAFTER PER PLAN BEAM PER PLAN SIMPSON MST STRAP PER PLAN B.N. ST R U C T U R E D E S I G N C O N S U L T A N T PE T E R C H A O & A S S O C I A T E S WOOD STUD SCHEDULE CONC. SLAB ON GRADE MIN. PLATE SPLICE CEILING JOIST SCHEDULE TYP. NOTCHING & BORING TYP. NAILING SCHEDULE TYPICAL HEADER 12345 678910 CONNECTION SHALL BE COMMON NAILS) 1. JOIST TO SILL OR GIRDER TOE NAIL. 2. BRAIDING TO JOIST TOE NAIL EA. END. 3. 1X6 SUB FIR OR LESS TO EA. JOIST FACE NAIL. 4. WIDER THAN 1X6 SUB FIR TO EA. JOIST FACE NAIL. 3 - 8d 5. 2" SUB FLOOR TO JOIST OR GIRDER BLIND & FACE NAIL 2 - 16d 6. SOLE PL. TO JOIST OR BLKING FACE NAIL 16d @ 16" O.C. 7. TOP PL. TO JOIST OR BLKING FACE NAIL 8. STUD TO SOLE PL. 4-8d TOE NAIL OR 2 - 16d END NAIL. 9. DOUBLE STUDS FACE NAIL. 16d @ 16" O.C. 10. DOUBLE TOP PLS FACE NAIL 16d @ 16" O.C. 11. TOP PLS. LAPS & INTERSECTIONS FACE NAIL. 2 - 16d 12. CONTINUOUS HDR. TWO PIECES. 16d @ 16" O.C. 13. CLG. JOISTS TO PL.TOE NAIL 3 - 8d 14. CONTINUOUS HDR. TO STUD TOE NAIL. 4 - 8d 15. CLG. JOIST LAPS OVER PARTITIONS FACE NAIL. 3 - 16d 16. CLG. JOIST TO PARALLEL RAFTERS FACE NAIL 3 - 16d 17. RAFTER TO PL. TOE NAIL. 3 - 16d 18. 1" BRACE TO EA. STUD & PL. FACE NAIL 2 - 8d 19. 1X8 SHT'G OR LESS TO EA. BEARING FACE NAIL 2 - 8d 20. WIDER THAN 1X8 SHT'G TO EA. BEARING FACE NAIL 3 - 8d 21. BUILT - UP CNR. STUDS. 16d @ 24" O.C. NAILING 3 - 16d 2 - 8d 2 - 8d 2 - 16d STUD 2X4 @ 16" 2X6 @ 16" 2X8 @ 16" 10' - 0" 14' - 0" 18' - 0" 14' - 0" 20' - 0" 24' - 0" MAX SUPPORT HEIGHT* BEAR'G WALL NON BAR'G WALL *MAX. DISTANCE BETWEEN FLOOR & ROOF. TABLE 23-IV-B 2X STUDS @ 16" O.C. U.N.O 16d @ 12" O.C.TYP. NOTE: SEE PALN FOR LOCATION PLYWOOD SHEATING 16d @ 12" O.C. #3X 3'-0" @ 24" O.C. SMOTH DOWELS 2X4 KEY CONT. 1 1/4" DEPTH SAWCUT OR QUICK JOIST @ 20'-0" EA. WAY MAX. (GROUT FILL) SLAB REINFORC'G WHERE OCCURS 1 -#4 CONT. NOTE: SEE NOTE ON FOUNDATION PLAN WHERE SAND & VISQUEEN APPLY. t t 1'-0"6"6"1'-0" 4" TYP. 8" 6" 7" MAX. SEE ARCH'S PLAN WHERE OCCURS SLAB REINFORC'G 2X F.J. 4' - 0" SPLICE AT LOWER PLATE 2-16d EA. SIDE OF SPLICE 16d @ 16" O.C. 20-16d EA. SIDE OF SPLICE PROVIDE STUD BELOW SPLICE LOWER SPLICE TOP SPLICE HANGER CLG. JOIST 2X BLK'G CLG. JOIST 2X DBL PLS. 2X STUDS @16"O.C.2X LEDGER W/2-16d @EA. STUD CEILING JOIST SCHEDULE SIZE 2X6 2X8 2X10 2X12 SPACING JOIST SPAN (MAX .)REMARKS 12" O.C. 14'-0" 16" O.C. 12'-2" 12" O.C. 18'-0" 16" O.C. 16'-0" 12" O.C. 22'-0" 16" O.C. 20'-6" 12" O.C. 26'-0" 16" O.C. 25'-0" CLG. JOISTS ARE DESIGNED FOR DRYWALL OR PLAST (D.L.=10 PSF N.L.L= 10PSF) THIS SCHEDULE APPLIES TO ALL RMS, U.N.O. ON PLANS SEE ARCH'L DRAWINGS FOR CLG. HEIGHT FIN. & SPECIFIC REQMTS. PLYWD. AS NOTED STUD @ 16" O.C. U.N.O. 2-2X EXECPT AS NOTED ON PLAN EDGE NAIL'G BOUNDARY NAILING STAGGERED PLYWD. SPLICES 2X BLOCKING TOP OF CONC. 2X P.T. SILL PL. W/ 5/8" O A.B SET 12" INTO CONCRETE @ 32" O.C. TYP U.N.O. NOTE: WHERE PLYWD. OCCUR @ EA. SIDE STAGG. PANEL JOINT. NAIL @ 12" O.C. INTERM NAILING 2X4 RAFTER TIE @ 48" O.C. W/ 5 - 16d NAIL @ EA. END 2X RAFT. SEE PLAN 2X BLOCKING @32" O.C. B.N. SIMPSON LPT4 @ 16" O.C. ROOF SHEATHING`2-2X RAFT.SEE PLAN A35 @ 16" O.C. 2X C.J. SEE PLAN2X C.J.B.N. B.N.2X C.J. SEE PLAN B PLYWD. SHEAT' G A35 @ 16" O.C. 2-2X BLK'G A 8-16d COMMON NAILSA35 @ 16" O.C. 2X C.J. SEE PLAN2X BLK'G EA. SIDE. SIMPSON LPT4 @ 16" O.C. 2X RAFT. SEE PLAN (ALL SHEAR WALLS AND ROOF AND FLOOR SHEATHING NAILS 4 57911 1012 68 WALL FOOTING ( EXT.) 2-#4 REBAR TOP & BOTTOM 4" CONC. 12" 3" MIN. 24" MIN. FINISH GRADE WEEP SCREED (26 gage) 8" MIN. 2 x P.T. SILL PL W/ 5/8" DIA. A.B X 12" SET 7" MIN. INTO CONC. @ 48" O.C. TYP. U.N.O. W/ 0.229" X 3" X 3" PLATE WASHERSSHEAR WALL SHEATHINGSEE PLAN 2X STUD@ 16" O.C #4 DOWEL @ 16" EA.WAY S-1 PE T E R C H A O & A S S O C I A T E S DATE DRAWN SCALE JOB NO. DWG. NO. P.C. 1/4" = 1'-0" 2 ft. 1 ft. HOLDOWN DETAIL NOTE: 1.HOLDOWN ANCHOR BOLT SHALL BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. BELOWP.T. SILL PLATE TOP OF SLAB WD. POST OR DBL STUD SDS SCREWS SIMPSON HOLDOWN SEE SCHEDULE BELOW A.B. TO CONFORM W/ SIMPSON SPEC. SEE MIN. EMBEDMENT SIMPSON HOLDOWN SCHEDULE A HDU2, HDU4, 6,10 SDS 1/4X2-1/2" B HDU5 SDS-2.5 14-SDS 1/4 X 2-1/2" C HDU8 SDS-2.5 20-SDS 1/4 X 2-1/2" 2.CHECK SIMPSON CATALOG MIN. EMBEDMENT FOR LARR25248 ER 4935 AT RIGHT SSTB A.B. SEE TABLE SSTB 20 SSTB 24 SSTB 28 16-5/8" 24-7/8" 3" 20-5/8" 10 ----- D HDU11 SDS-2.5 30-SDS 1/4X 2-1/2"1" Ø SIMPSON PAB8 A.B.13-1/2" 3 2 1 WALL FOOTING ( INT.) 4" CONC. 24 " M I N . 2-#4 CONT. TOP & BOTTOM 3" MIN. 2X STUD@ 16" O.C INTO CONC. @ 48" O.C. TYP. U.N.O. PLATE WASHERS W/ 0.229" X 3" X 3" 2 x OR 3X P.T. SILL PL W/ 5/8" DIA. A.B X 12" SET 7" MIN. FOR CONCRETE GRADE BEAM 2-#4 CONT. TOP & BOTTOM 4" CONC. 3" MIN. FINISH GRADE6" WEEP SCREED (26 GAGE) 8" MIN. SHEAR WALL SHEATHING SEE PLAN 2X STUD@ 16" O.C #4 REBAR @ 16" EA.WAY2 ft. 1 ft. SIMPSON HOLDOWN 12" 39 5 4 E . A T T T A L L A S T R E E T , O N T A R I O C A 9 1 7 6 1 ST R U C T U R E D E S I G N C O N S U L T A N T TE L : ( 9 0 9 ) 6 8 0 - 2 7 2 7 4" CONC. SLAB W/ SEE SPECIAL INSPECTION PROGRAM IN SHEET S-3.SEE STRUCTURAL OBSERVATION PROGRAM IN S-3. COLD JOINTROUGH SURFACE(OPTION FOR TWO POUR) 1-#4 REBAR COLD JOINTROUGH SURFACE(OPTION FOR TWO POUR) 24 " M I N . #4 DOWEL @ 16" EA.WAY 2 ft. 1 ft. COLD JOINTROUGH SURFACE(OPTION FOR TWO POUR) 1-#4 REBAR 08/04/2024 GL 20240804 AR C A D I A , C A 9 1 0 0 6 12 2 C A L I F O R N I A S T R E E T 4" CONC. SLAB W/#4 REBAR @ 16" O.C. EA. WAY 4" CONC. SLAB W/#4 REBAR @ 16" O.C. EA. WAY #4 REBAR @ 16" O.C. EA. WAY E HD 9B (3) 7/8" Ø BOLT F HDU14 SDS-2.5 36-SDS 1/4X 2-1/2" SSTB 2824-7/8" 1" Ø SIMPSON PAB8 A.B.13-1/2" they shall be distributed so that the load does not exceed the design live load. 8. Where construction materials are temporarily stored on roof or floor framing, contract documents. details, the Architect shall be notified and he will interpret the intent of the specifications and notes on the drawings of between general notes and specific 7. In all cases where a conflict may occur, such as between item covered in structural work. and other items to be embedded in concrete or otherwise incorporated in openings required for ducts, pipes and for all pipe sleeves, electrical conduits 6. See mechanical, plumbing and electrical drawing for size and location of all shall check all dimensions. 5. The contractor shall be responsible for coordinating the work of all trades and National State and Local safety ordinances. construction. Safety and bracing requirements shall be in accordance with all construction and shall provide adequate shoring , bracing and guide during 4. The contractor shall be responsible for the safety of the building during 3. All materials and workmanship shall conform to the drawing and specifications. 2. All work shall conform to the requirements of the code. 1. "Code" where referred to herein refers to C.B.C building Code 2022 Edition. GENERAL NOTES: 8. Saturate the soil 18" deep before placing the concrete slab.9. Grading & footing to inspected & certified by the soil engineer prior to pouring the concrete. 7. All Holddown hardware, anchor bolts & rebar to be secured in place prior to @ 48" O.C with plate washer 3x3x0.229" unless noted. 5. Shear walls denote full length and full height of the wall. 4. See detail on 1/S-1 for typical slab on grade. control joints, and slab3. See detail on plan/S-1 for shear wall indicated by 1. For floor dimension, curbs, under floor ducts, conduits, etc. 6. Anchor bolts are 5/8" Ø depression details. 2. Verify all condition in field. call inspection. FOUNDATION NOTES: provisions outlined in Portland Cement Association Spec. ST26. 5. vibration: Vibration of concrete shall be in accordance with the general 4. Maximum slump of concrete used in floor slab at flat work shall be four(4) 3. Strengths: Ultimate compressive strength 28 days ----F'c=2500 psi. shrinkage characteristics of less than 0.04 type (150 Ib/ cu. ft.). Aggregate shall conform to A.S.T.M. C-33 with proven 2. All concrete unless otherwise noted on plans will be regular weight hard rock 1. Cement : Type I or Type II conforming to A.S.T.M. C-150 C.B.C. inches. CONCRETE: % as per A.S.T.M C-157 foundation inspection. 10. Continuous inspection required for concrete F'c greater than 2500 psi. 9. Location of construction and pour joints shall be approved by the Architect before pouring concrete. 8. Anchor bolts, dowels, inserts, etc. shall be securely tied in place prior to specification reports to be forward to the structural engineer.7. Strength tests of concrete shall be required as per code and as outlined in five days after it placement. Approved curing compounds may be used in lieu 6. Curing: Concrete shall be maintained in a moist condition for a minimum of of moist curing. detailed on plans. In contact with earth (formed) 2" clear otherwise noted: Deposited against earth 3" clear 5. Provide the following minimum protective covering of concrete unless latest edition of "The manual of Reinforcing Steel Practice for Reinforced 4. All reinforcing steel shall be supported and tied in conformance with the 3. Certification and testing of reinforcing steel shall be in accordance with the Concrete Structures". provision of A.S.T.M. standards. or 2'-0" minimum whichever governs. All splices shall be located as 2. Unless otherwise noted, all reinforcing steel shall be lapped 36 bar diameter b. Deformations shall be in accordance with A.S.T.M. A305. 1 a. All reinforced steel to conform to A.S.T.M. specification A615 Grade 60 unless noted otherwise on plans. REINFORCING STEEL: FRAMING NOTES: 4. See 11/S-2 for typical wall sheathing detail. 3. Wood diaphragm to be inspected and approved by Building 10" O.C> in intermediated (field). 6" O.C. in all other edges, with 10d common nail at: 6" O.C. in boundary, 2. Floor sheathing to be 5/8" CD T&G plywood or OSB (INDEX 32/16) 12" O.C. in intermediated (field). 6" O.C. in all other edges, 8d common nail at: 6" O.C. in boundary,1. Roof sheathing to be 1/2" CDX plywood or OSB (INDEX 24/0) with Department prior to covering. 11. The max. depth of notching shall not exceed 1/4 the depth at the end of spans. 18. roof plywood shall be bond w/ INT. & EXT. type where exposed to weather. 17. Stucco lath & drywall shall be nailed to all studs & to top & bottom PL. 16. 2--layer #15 black paper covered plywood sheathing for shear wall. 15. Holddown shall be tight before covered plywood sheathing. 14. Roof sheathing requires nailing inspection before covered. 13. Provide double joist under parallel bearing partitions.12. Provide solid 2x blocking under partitions perpendicular to floor joist. and shall not be located in the middle 1/3 of the span. of the span.10. The max. depth of notching shall not exceed 1/6 the depth of the member. 9. A certificated of compliance will be provided for the laminated beams.8. Structural observation will be performed when required by the Building official.7. See shear wall denote full length and full height of the walls.6. See detail on framing plan for shear wall indicated by 5. See 3/S-2 for typical diaphragm detail and notes. b. 4x grade No.1 typical U.N.O. 11. Joist hangers and other connectors shall be Simpson strong ties or equal. 10. All wood bearing on concrete or masonry shall be pressure treated Douglas Fir. diaphragm nailing requirements. 9. Edges of all opening through roof or floor shall be nailed per boundary of plywood shall be identified by a registered stamp or brand. plans with exterior glue conforming to product Standard PSI--95. Each sheet 8. Structural plywood shall be DEPA grade, Structural I, thickness as noted on 7. Minimum nailing for all wood members shall be as per code unless specifically noted detailed or approved by the Architect.6. Framing members shall not be notched in any manner except where specifically 5. Standard steel washers shall be used on all heads and nuts bearing on wood. 4. The bridging shall be provided as per code. than 4'-0" O.C. unless noted otherwise, there shall be one bolt within 9" of each Douglas Fir bolted to concrete with 5/8" x 10" anchor bolt space not more 3. Sills under stud partitions in contact with concrete shall pressure treated.2. Studs, plates, sills and blocking to be grade #2 Douglas Fir or better c. post grade No.1 typical U.N.O. a. 2x grade No.2 typical U.N.O.1. All horizontal load carrying member and posts to be Douglas Fir Larch north.WOOD FRAMING: 4. Building Weight = 86.578 kips. 3. Response Modification Coefficient. R=6.5 (Wood Structure Panel) SDS = 1.551, SD1 = 0.787. Design Seismic Force (ASD value) = 18.802 kips. Site Class D, Ss = 1.939 S1 = 0.694, SMs = 2.327, SM1 = 1.18 2. Seismic Design Data: Seismic Design Category : D f. Floor Live Load =40 psf e. Floor Dead Load =15.1 psf b. Typical live load for roof =20 psf a. Dead loads for roof =11.1 psf 1. Design Load: STRUCTURE DESIGN DATA drawings to the Architect for approval prior to fabrication. specializing in this type of work. The fabricator shall submit complete shop 5. The glued laminated beams shall be furnished by a licensed fabricator shall be accompanied by a Certificate of inspection. 4. Each glued laminated beam shall be stamped with identification number and Architect & building department prior to erection. approved inspection agency. A certificate of inspection shall be provided for the 3. All structural glued laminated timber shall be inspected during lamination by an AITC 117-71 or combination 24F-V8 with hem fir lamination per AITC. 2. Glued laminated beams shall be combination 24F-V4, Douglas Fir and Larch per commercial standard, CS-253, 1. Materials, manufacture and quality control shall be in conformance with STRUCTURAL GLUE LAMINATED TIMBER: "Structural Glued Laminated Timber" 5. Provide tests as may be required by the building official. parts sand and two parts pea gravel to be of fluid consistency. compressive strength of 2500 psi at 28 days. Use one part cement, three 4. Grout used shall conform to A.S.T.M. designation C476-71 with a minimum putty, and four and one-half parts sand. 2500 psi at 28 days. Mix one part Portland Cement, one half part lime 3. Mortar used shall be Type S with a minimum compressive strength of 2. All units shall have a minimum compressive strength of 1500 psi. 1. Concrete block, Type I, Grade N-1. MASONRY NOTES: inspector prior to framing approval. to the job inspector prior to framing approval. 10. A certificate of fabrication or report from the special inspector must be furnished exercised to prevent undercutting or reducing the selection of materials at welds. deposited by not more than 1/4" thick passes. Particular care shall be shall have 1/4" extra length each end to allow for craters. Weld shall be noted on details are net and do not include allowance for craters. All welds warping or distortion of the structural members be minimized. Length of welds suitable means for clamping or holding members during welding in order that requirements for electric arc welding of AWS Spec. The contractor shall provide experienced and certified welders in accordance w/ the standards and electrodes in conformation to local building code. All welding shall be done by 9. Electric arc weld process by operators approved by board of AWS using E--70xx be a part of the special inspection required of section. compliance with approved standards and job specification. This testing shall 8. Ordinary moment framing shall be test by nondestructive methods for welding and ordinary framing. 7. Continuous Inspection required during installation of High--Strength bolts field place as directed by the manufacturer. 6. All grout under steel bearing plates shall be solid drypack or non--shrink grout the Architect and approval obtained prior to fabrication. 5. Shop drawing s for all structural and miscellaneous steel shall be submitted to the fabrication or report from the special inspection must be furnished to the job approved by L.A. city or county building department and a certificate of 4. All structural steel shall be fabricated and erected by a licensed fabricator 3. All bolts used shall conform to A325 unless otherwise noted. continuous inspection is required for field welds. in the shop of a licensed fabricator, except where otherwise noted on plans. per the A.I.S.C specification. Welds are designed at full stress and must be down electric arc process and shall be performed with approved electrodes as required approved by the Department of Building and Safety. All weldings will be done2. All welding is to comply with A.W.S specifications and is to be done by welders on plans.1. Shall conform to the provisions of A.S.T.M. A--36 unless otherwise noted STRUCTURAL STEEL 5/8" ØA.B. 5. 1/2" edge distance for plywood boundary nailing. 4. All bolt holes shall be drilled a Max. of 1/16" oversized. boundary nail shall be staggered. typical. (reduced diameter nails prohibited) than 350 pounds/foot require a 3 inch nominal or greater member. The 3. Sill PL. & Studs @ edge of plywood for shear walls with lateral loads greater shall be tightened just prior to covering the wall framing 2. Hold--down connector bolts into wood framing requires. 1. Hold--down hardware secured in place prior to calling inspector. @ T & B. PLATE EDGE & FIELD ( 16d SILL NAIL @ 6" O.C.) 7/8" STUCCO OVER PAPER BACK'D LATH WITH 16 GA. STAPLES @ 6" O.C. SHEAR WALL SCHEDULE 6. A.B. into wood framing require 3" x 3" x .229" plate washers for 3" x 3" x 5/16" plate washers for 3/4 Ø A.B. and holddown 5/8" Ø @ 32" o.c.16d @ 4" o.c.12668d15/32" STR'L I 5 4 3 2 12 12 12 1215/32" STR'L I 870 665 510 340 15/32" STR'L I 10d 2 10d 3 2 3 10d 4 10d 6 4 6 5/8" Ø @ 12" o.c. 5/8" Ø @ 16" o.c. 5/8" Ø @ 18" o.c. 5/8" Ø @ 28" o.c. 3/8" o L.G.@ 6"o.c. 20d @ 2 1/2"o.c. 20d @ 3" o.c. 16d @ 3" o.c. see #3 see #3 --- 1 MARK BOUND CAPACITY 280 #/LF 4 OR 5 LAY OR OSB PLYWOOD BOUND SPACING NAIL EDGE SILL BOLTSSILL NAIL REMARK --- 15/32" STR'L I 15/32" STR'L I see #3 SOIL INFO.: 24" below lowest finished grade is: 1500 psf. for spread footings, 1500 psf. 2. The soil bearing value used for design of footing upon undisturbed soils and 1. The foundation designed is based on the recommendations by C.B.C. TABLE 1806.2. 5. Seismic Resistance System = Light Frame(wood) wall sheathed plywood system. Seismic Resistance Coeff., Cs = 0.239. 6. Wind Load Design Data: Basic Wind Speed: 95 mph. Occupancy Category = II. Exposure Category = C., Adjustment coefficient = 1.3 ʎ Wind Load: (longitudinal direction) = 11.842 kips (ASD value). Seismic Load Control. SIMPSON A35 OR LPT4 TIE @ 16" O.C. @ 16" O.C. @ 16" O.C. @ 12" O.C. @ 8" O.C. 2" (TYPICAL) (TYPICAL) L I NFORC VEATOFA C OI A G I L E N N E RE N AI E ES IGS RE E H D CGNO P R O TER U F CS T I N S NO. C-68688 Exp.09/30/25 LI H HA O LC V E AT OF A E ES IGS RE E H D CGNO P R O TER U F CS T I N S NO. C-68688 Exp.09/30/25 LI H d. Typical live load for ceiling =10 psf c. Dead loads for ceiling = 6.1 psf 12" B.N. B.N. B.N. SHEAR WALL SHEATHINGWHERE OCCUR 12" 12" OVER 15 MIL. MOISTURE BARRIER OVER 4" THICK BASE OF 1/2" OR LARGER CLEAN AGGREGATE OVER 15 MIL. MOISTURE BARRIER OVER 4" THICK BASEOF 1/2" OR LARGER CLEAN AGGREGATE 2-2X TOP PLATE 2X CRIPPLE STUD WINDOW HEADER PER PLAN SIMPSON MST27 STRAP OR PER PLAN 4X4 OR 4X6 BLOCKING 2X OR 3X SILL PLATE POST FORHEADERPER PLAN SIMPSON MST27 WINDOWOPENING2X KING STUD NOTE: OPENING WIDTH > = 6'-0" NEED OPENING STRENGTHEN STRAP OR PER PLAN 2X TRIMMER OR 4X4 OR 4X6BLOCKING ROOF TO WALL B.N. 2X BLOCKING 16" O.C. 2X C.J. SEE PLAN 2X FLAT @ ROOF SHEATHING PER PLAN 2X BALLOON FRAMING 2X R.R. PER PLAN2X FACIAL BOARD 2X BLOCK W/ 2-16d COMM. NAILS @ 12" O.C. TO TOP PLATE SIMPSON LPT4 @ 16" O.C. B.N. (2-2x DIAPHRAGM CHORD) TOP PLATE 2X SIMPSON A35 @ 32" O.C. OVER 15 MIL. MOISTURE BARRIER OVER 4" THICK BASE OF 1/2" OR LARGER CLEAN AGGREGATE ROOF SHEAT'G ROOF RAFTER 2-2X4 TOP PLATE ROOF VENT OPENING RIDGE BEAM PER PLAN 4X4 KING POST PER PLAN 4X6 HEADER 2X SILL PLATE 2X BALLOON FRAMING CALIF. ROOF ROOF SHEATHING PER PLAN RIDGE BEAM PER PLAN SIMPSON MST27 STRAP SIMPSON CC44 CAP SIMPSON A35 BOTH SIDE 4X4 KING POST BEAM PER PLAN OR 2X STUD WALL 2X CEILING JOIST PER PLAN RIDGE BEAM PER PLAN (N) ROOF SHEATHING PER PLAN (N) RIDGE BEAM PER PLAN (N) SIMPSON MST37 STRAP (N) SIMPSON CC44 CAP (N) SIMPSON A35 BOTH SIDE (N) 4X4 KING POST (E) 2X CEILING JOIST (E) RIDGE BEAM PER PLAN (N) 2X4 FLAT (E) ROOF SHEATHING ROOF SHEATHING PER PLAN RIDGE BEAM PER PLAN SIMPSON MST37 STRAP SIMPSON CC44 CAP SIMPSON A35 BOTH SIDE 4X4 KING POST 2X4 STUD WALL 2X CEILING JOIST RIDGE BEAM PER PLAN ROOF SHEATHING B.N. ROOF SHEAT'G 2X R.R. 2X R.B. PER PLAN 2X CRIPPLE WALL2X R.R.PER PLAN 2X C.J. PER PLAN 2X STUD WALL PER PLAN SHEAR WALLSHEAT'G SHEAR WALLSHEAT'G 2X C.J. PER PLAN 2X BLK'G 2X BLK'G SIMPSON A35@ 16"O.C. SIMPSON A35@ 16"O.C. COLD JOINT DETIAL EXIST'G FOOTING 2-#4 DOWELS X 24" LONG T&B W/ SIMPSON SET-XP EPOXY ADHESIVE ANCHOR MIN. 8" INTO EXISTING FOOTING. SPECIAL INSPECTION REQUIRED. 8" NEW FOOTING 8" ICC ESR-2508 24" MIN. OVERLAP EXISTING CONC. FTG. SEE PLAN 14" FOOTING UNDERPIN 2X OR 3X P.T. PLATE REBAR SEE PLAN 2 CONCRETE FOOTING UNDERPIN WALL FOOTING ( INT.) 4" CONC. 24" MIN. 14"2-#4 CONT. TOP & BOTTOM 3" MIN. 2X STUD WALL PER PLAN 6" 6" #4 DOWEL @ 24" O.C. SIMPSON SET-XP STURCTURE EPOXY TIE (ICC ESR 2508)DRILL HOLE WITH 5/8" Ø. #4 DOWEL @ 24" O.C. (E) CONC. SLAB(E) CONC. SLAB 2X SILL PLATE 6" 6" 14" 24 " . 3" (N) 2X STUD WALL PER PLAN (E) CONCRETE SLAB (E) CONCRETE FOOTING NEW CONCRETE FOOTING 2-#4 REBAR TOP AND BOTTOM 10" MIN. #4 DOWELS W/ SIMPSON SET-XP EPOXY ADHESIVE ANCHOR MIN. 6" INTO EXISTING FOOTING. @ 16" O.C. SPECIAL INSPECTION REQUIRED. 6" #4 DOWEL @ 24" O.C. (E) CONC. SLAB #4 DOWELS W/ SIMPSON SET-XP EPOXY ADHESIVE ANCHOR MIN. 6" INTO EXISTING FOOTING. @ 16" O.C. SPECIAL INSPECTION REQUIRED. INTO CONC. @ 48" O.C. TYP. U.N.O. PLATE WASHERS W/ 0.229" X 3" X 3" 2 x OR 3X P.T. SILL PL W/ 5/8" DIA. A.B X 12" SET 7" MIN. INTO CONC. @ 48" O.C. TYP. U.N.O. PLATE WASHERS W/ 0.229" X 3" X 3" 2 x OR 3X P.T. SILL PL W/ 5/8" DIA. A.B X 12" SET 7" MIN. (N) BEAM PER PLAN (E) BEAM PER PLAN SIMPSON HU HANGER SIZE TO MATCH TO (E) BEAM (E) BEAM PER PLAN (E) 2X CEILING JOIST (N) 2X BLOCKING (N) 2X4 STUD WALL 3-16d TOE NAILSEACH BLOCK AT EACH SIDE LE G A L I Z I N G U N P E R M I T T E D N O N - L I V A B L E S P A C E IN T O A N A T T A C H E D A C C E S S O R Y D W E L L I N G U N I T (N) LATICRETE HYDRO BAN WATER PROOFING (ICC-ESR 2417)2-LAYER (N) LATICRETE HYDRO BAN WATER PROOFING (ICC-ESR 2417)2-LAYER 12 2 C A L I F O R N I A S T R E E T LE G A L I Z I N G U N P E R M I T T E D N O N - L I V A B L E S P A C E IN T O A N A T T A C H E D A C C E S S O R Y D W E L L I N G U N I T ROOF SHEATHING 2X R.R. 6-16d COMM. NAILS B.N. B.N. 2X FACIAL BOARD 2X C.J. PER PLAN 2X STUD WALL SIMPSON A35 @ 16" O.C. B.N. T & G BOARD 2-2X TOP PLATE ROOF SHEATHING 2X R.R. 6-16d COMM. NAILS B.N. 2X FACIAL BOARD 2X C.J. PER PLAN 2X STUD WALL SIMPSON A35 @ 16" O.C. B.N. T & G BOARD 2-2X TOP PLATE 2X RAFTER TIE @ EA. RATER A B DROP BEAMWHERE OCCUR DROP BEAMWHERE OCCUR B.N. DOUBLE SIDE SHEAR WALL WHERE OCCUR (E) R.R (E) ROOF SHEATHING B.N. (N) ROOF SHEATHING PER PLAN (N) 2X R.R. PER PLAN (N) 2X BLOCKING 6 2X4 STUD WALL 2-2X TOP PLATE ROOF SHEATHING 2-2X ROOF RAFTER PER PLAN BEAM PER PLAN SIMPSON MST STRAP PER PLAN B.N. S-2 DATE DRAWN SCALE JOB NO. DWG. NO. P.C. 1/4" = 1'-0" BEAM TO POST CONN. ST R U C T U R E D E S I G N C O N S U L T A N T PE T E R C H A O & A S S O C I A T E S WOOD STUD SCHEDULE CONC. SLAB ON GRADE MIN. PLATE SPLICE CEILING JOIST SCHEDULE TYP. NOTCHING & BORING TYP. NAILING SCHEDULE TYPICAL HEADER TYPICAL WALL SHEATHING 12345 678910 1115 1718 1214 1619 CONNECTION SHALL BE COMMON NAILS) 1. JOIST TO SILL OR GIRDER TOE NAIL. 2. BRAIDING TO JOIST TOE NAIL EA. END. 3. 1X6 SUB FIR OR LESS TO EA. JOIST FACE NAIL. 4. WIDER THAN 1X6 SUB FIR TO EA. JOIST FACE NAIL. 3 - 8d 5. 2" SUB FLOOR TO JOIST OR GIRDER BLIND & FACE NAIL 2 - 16d 6. SOLE PL. TO JOIST OR BLKING FACE NAIL 16d @ 16" O.C. 7. TOP PL. TO JOIST OR BLKING FACE NAIL 8. STUD TO SOLE PL. 4-8d TOE NAIL OR 2 - 16d END NAIL. 9. DOUBLE STUDS FACE NAIL. 16d @ 16" O.C. 10. DOUBLE TOP PLS FACE NAIL 16d @ 16" O.C. 11. TOP PLS. LAPS & INTERSECTIONS FACE NAIL. 2 - 16d 12. CONTINUOUS HDR. TWO PIECES. 16d @ 16" O.C. 13. CLG. JOISTS TO PL.TOE NAIL 3 - 8d 14. CONTINUOUS HDR. TO STUD TOE NAIL. 4 - 8d 15. CLG. JOIST LAPS OVER PARTITIONS FACE NAIL. 3 - 16d 16. CLG. JOIST TO PARALLEL RAFTERS FACE NAIL 3 - 16d 17. RAFTER TO PL. TOE NAIL. 3 - 16d 18. 1" BRACE TO EA. STUD & PL. FACE NAIL 2 - 8d 19. 1X8 SHT'G OR LESS TO EA. BEARING FACE NAIL 2 - 8d 20. WIDER THAN 1X8 SHT'G TO EA. BEARING FACE NAIL 3 - 8d 21. BUILT - UP CNR. STUDS. 16d @ 24" O.C. NAILING 3 - 16d 2 - 8d 2 - 8d 2 - 16d STUD 2X4 @ 16" 2X6 @ 16" 2X8 @ 16" 10' - 0" 14' - 0" 18' - 0" 14' - 0" 20' - 0" 24' - 0" MAX SUPPORT HEIGHT* BEAR'G WALL NON BAR'G WALL *MAX. DISTANCE BETWEEN FLOOR & ROOF. TABLE 23-IV-B 2X STUDS @ 16" O.C. U.N.O 16d @ 12" O.C.TYP. NOTE: SEE PALN FOR LOCATION PLYWOOD SHEATING 16d @ 12" O.C. #3X 3'-0" @ 24" O.C. SMOTH DOWELS 2X4 KEY CONT. 1 1/4" DEPTH SAWCUT OR QUICK JOIST @ 20'-0" EA. WAY MAX. (GROUT FILL) SLAB REINFORC'G WHERE OCCURS 1 -#4 CONT. NOTE: SEE NOTE ON FOUNDATION PLAN WHERE SAND & VISQUEEN APPLY. t t 1'-0"6"6"1'-0" 4" TYP. 8" 6" 7" MAX. SEE ARCH'S PLAN WHERE OCCURS SLAB REINFORC'G 2X F.J. 4' - 0" SPLICE AT LOWER PLATE 2-16d EA. SIDE OF SPLICE 16d @ 16" O.C. 20-16d EA. SIDE OF SPLICE PROVIDE STUD BELOW SPLICE LOWER SPLICE TOP SPLICE HANGER CLG. JOIST 2X BLK'G CLG. JOIST 2X DBL PLS. 2X STUDS @16"O.C.2X LEDGER W/2-16d @EA. STUD CEILING JOIST SCHEDULE SIZE 2X6 2X8 2X10 2X12 SPACING JOIST SPAN (MAX .)REMARKS 12" O.C. 14'-0" 16" O.C. 12'-2" 12" O.C. 18'-0" 16" O.C. 16'-0" 12" O.C. 22'-0" 16" O.C. 20'-6" 12" O.C. 26'-0" 16" O.C. 25'-0" CLG. JOISTS ARE DESIGNED FOR DRYWALL OR PLAST (D.L.=10 PSF N.L.L= 10PSF) THIS SCHEDULE APPLIES TO ALL RMS, U.N.O. ON PLANS SEE ARCH'L DRAWINGS FOR CLG. HEIGHT FIN. & SPECIFIC REQMTS. PLYWD. AS NOTED STUD @ 16" O.C. U.N.O. 2-2X EXECPT AS NOTED ON PLAN EDGE NAIL'G BOUNDARY NAILING STAGGERED PLYWD. SPLICES 2X BLOCKING TOP OF CONC. 2X P.T. SILL PL. W/ 5/8" O A.B SET 12" INTO CONCRETE @ 32" O.C. TYP U.N.O. NOTE: WHERE PLYWD. OCCUR @ EA. SIDE STAGG. PANEL JOINT. NAIL @ 12" O.C. INTERM NAILING 20 BEAM SEE PLANBEAM SEE PLAN BEAM SEE PLANBEAM SEE PLAN SIMPSON ECCQ COL. CAPOR SEE PLAN SIMPSON CC. COL. CAP OR SEE PLAN SPLICE WHERE OCCUR MST STRAP SIMPSON EPCZ CAP OR SEE PLAN WD COL SEE PLAN WD COL SEE PLANWD COL SEE PLAN WD COL SEE PLAN SIMPSON PC POST CAPOR SEE PLAN SPLICE WHERE OCCUR A B C D PER PLAN MST STRAP PER PLAN TE L : ( 9 0 9 ) 6 8 0 - 2 7 2 7 2X4 RAFTER TIE @ 48" O.C. W/ 5 - 16d NAIL @ EA. END 13 2X RAFT. SEE PLAN 2X BLOCKING @32" O.C. B.N. SIMPSON LPT4 @ 16" O.C. ROOF SHEATHING`2-2X RAFT.SEE PLAN A35 @ 16" O.C. 2X C.J. SEE PLAN2X C.J.B.N. B.N.2X C.J. SEE PLAN B PLYWD. SHEAT'G A35 @ 16" O.C. 2-2X BLK'G A 8-16d COMMON NAILSA35 @ 16" O.C. 2X C.J. SEE PLAN2X BLK'G EA. SIDE. SIMPSON LPT4 @ 16" O.C. 2X RAFT. SEE PLAN (ALL SHEAR WALLS AND ROOF AND FLOOR SHEATHING NAILS 2-2X TOP PLATE L I NFORC V E AT OF A C OI A G I L E N N E RE N AI E ES IGS RE E H D CGNO P R O TER U F CS T I N S NO. C-68688 Exp.09/30/25 LI H HA O 2-2X TOP PLATE 2X CRIPPLE STUD WINDOW HEADER PER PLAN SIMPSON MST27 STRAP OR PER PLAN 4X4 OR 4X6 BLOCKING 2X OR 3X SILL PLATE POST FORHEADERPER PLAN SIMPSON MST27 WINDOWOPENING2X KING STUD NOTE: OPENING WIDTH > = 6'-0" NEED OPENING STRENGTHEN STRAP OR PER PLAN 2X TRIMMER OR 4X4 OR 4X6BLOCKING ROOF TO WALL B.N. 2X BLOCKING 16" O.C. 2X C.J. SEE PLAN 2X FLAT @ ROOF SHEATHING PER PLAN 2X BALLOON FRAMING 2X R.R. PER PLAN2X FACIAL BOARD 2X BLOCK W/ 2-16d COMM. NAILS @ 12" O.C. TO TOP PLATE SIMPSON LPT4 @ 16" O.C. B.N. (2-2x DIAPHRAGM CHORD) TOP PLATE 2X SIMPSON A35 @ 32" O.C. ROOF SHEAT'G ROOF RAFTER 2-2X4 TOP PLATE ROOF VENT OPENING RIDGE BEAM PER PLAN 4X4 KING POST PER PLAN 4X6 HEADER 2X SILL PLATE 2X BALLOON FRAMING CALIF. ROOF (N) ROOF SHEATHING PER PLAN (N) RIDGE BEAM PER PLAN (N) SIMPSON MST37 STRAP (N) SIMPSON CC44 CAP (N) SIMPSON A35 BOTH SIDE (N) 4X4 KING POST (E) 2X4 STUD WALL (E) 2X CEILING JOIST (E) RIDGE BEAM PER PLAN (N) 2X4 FLAT (E) ROOF SHEATHING (E) 2X BLOCKING ROOF SHEATHING PER PLAN RIDGE BEAM PER PLAN SIMPSON MST37 STRAP SIMPSON CC44 CAP SIMPSON A35 BOTH SIDE 4X4 KING POST 2X4 STUD WALL 2X CEILING JOIST RIDGE BEAM PER PLAN ROOF SHEATHING 39 5 4 E . A T T T A L L A S T R E E T , O N T A R I O C A 9 1 7 6 1 (N) BEAM PER PLAN (E) BEAM PER PLAN SIMPSON HU HANGER SIZE TO MATCH TO (E) BEAM (E) BEAM PER PLAN (E) 2X CEILING JOIST (N) 2X BLOCKING (N) 2X4 STUD WALL 3-16d TOE NAILSEACH BLOCK AT EACH SIDE 08/04/2024 GL 20240804 AR C A D I A , C A 9 1 0 0 6 12 2 C A L I F O R N I A S T R E E T LE G A L I Z I N G U N P E R M I T T E D N O N - L I V A B L E S P A C E IN T O A N A T T A C H E D A C C E S S O R Y D W E L L I N G U N I T SPECIAL INPECTION PROGRAM 1. The owner or the agent of the owner shall be responsible for employing the special inspector(s) as required by CBC Code SECTION 1701.1 for the construction project located at: 2. The following list of work (only checked items are required ) for Special Inspection: SOIL COMPLIANCE PRIOR TO FOUNDATION INSPECTION FIELD WELDING STRUCTURAL CONCRETE OVER 2500 PSI HIGH STRENGTH BOLTING PRESTRESSED / POSTENTION CONCRETE EXPANSION / EPOXY ANCHORS STRUCTURAL MASONRY SPRAYED-ON FIREPROOFING DESIGNER SPECIFIED OTHERS 3. Duties of the Special Inspector for the work listed above: A. B. C. D. SPECIAL INSPECTOR SHALL CHECK IN WITH THE CITY OR COUNTY AND PRESENT THEIR CREDENTIAL FOR APPROVAL PRIOR TO BEGINING WORK ON THE JOB. 122 CALIFORNIA STREET, ARCADIA CA 91006The Special Inspector shall inspect the foundation size, depth, grade beam rebar size, number, tie rebar and spacing, the anchor bolts size, embedment depth, the wood strong wall panels size, connection straps. SPECIAL INSPECTOR SHALL CHECK ALL SIMPSON WOOD STRONG WALL INSTALLATION following the details from the WSW plans and reference to ICC-ESR 2652 code report. CHECK SIMPSON SET XP ADHESIVE FOR ANCHOR BOLTS TO EXISING CONCRETE ACCORDING TO ICC-ESR 2508. S-3 DATE DRAWN SCALE JOB NO. DWG. NO. P.C. 1/4" = 1'-0" PE T E R C H A O & A S S O C I A T E S ST R U C T U R E D E S I G N C O N S U L T A N T TE L : ( 9 0 9 ) 6 8 0 - 2 7 2 7 L I NFORC V E AT OF A C OI A G I L E N N E RE N AI E ES IGS RE E H D CGNO P R O TER U F CS T I N S NO. C-68688 Exp.09/30/25 LI H HA O 2.A.B. INTO WOOD FRAMING REQUIRE 3"X3"X0.229" 3.PROVIDE 5/8" Ø A.B @ 42" O.C FOR NON SHEAR WALL . PLATE WASHERS FOR 5/8" Ø A.B. AND MIN 7" EMBEDMENT INTO CONC. SEE THE SHEAR WALL SCHEDULE TABLE ON S-1. SIZE & SPACING OF THE ANCHOR BOLT(A.B.). 1. FOLLOW THE SHEAR WALL SCHEDULE FOR THE FOUNDATION NOTE: 4. A MINIMUM TWO BOLTS PER PIECE OF SILL PLATE. 5. ALL HOLDOWN HARDWARE IS TO BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. 6.ONE LOCATED WITHIN 12" AND NOT LESS THAN 7 BOLT DIAMETER OR 4-3/8" OF EACH END OF EACH SILL PLATE. 7. FOUNDATION SILL PLATE SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. FIELD-CUT, NOTCHES AND DRILLED HOLES OF PRESERVATIVE-TREATED WOOD SHALL BE FIELD-TREATED PER AWPA M4. 8. SATURATE THE SOIL 24 INCH DEEP BEFORE PLACING THE CONCRETE SLAB. 9. THE HOLE IN THE PLATED WASHER IS PERMITTED TO BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 3 16 in. LARGER THAN THE BOLT DIAMETER AND A SLOT LENGTH NOT TO EXCEED 1- 3 4 in., PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. 10. FASTENERS FOR PRESERVATIVE-TREATED WOOD SHALL BE HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. THE COATING WEIGHTS FOR ZINC-COATED FASTENERS SHALL BE ACCORDANCE WITH ASTM A 153. Couty of Los Angeles DEPARTMENT OF PUBLIC WORKS BUILDING AND SAFETY DIVISION Los Angeles Regional Uniform Program STRUCTURAL OBSERVATION PROGRAM AND DESIGNATION OF THE STRUCTURAL OBSERVER PERMIT APPL. NO.: Project Address: Description of Works: Owner: Engineer of Record: Architect: STRUCTURAL OBSERVATION (ONLY CHECKED ITEMS ARE REQUIRED) Firm or individual to be responsible for the Structural Observatoin: Name:Phone:Calif. Registration: Footing, Stem Walls, Piers Mat Foundation Caisson, Piles, Grade Beams Retaining Foundation Hill Side Special Anchor Others: Concrete Masonry Wood Others: Steel Moment Frame Steel Brace Frame Concrete Moment Frame Concrete Steel Deck Wood Masonry Wall Frame Others: Others: FOUNDATIONWALLFRAMEDIAPHRAGM DECLARATION BY OWNER I, The Owner of the project, declare that the above listed firm or individual is hired by me to be the The Structural Observer SignatureDate DECLARATION BY ARCHITECT OR ENGINEER OF RECORD (required if the Structural Oberver is different from the Architect or Engineer of Record) I, the Architect or Engineer of record of the project, declare that the above listed firm or individual is designated by me to be responsible for the Structural Observation. SignatureDateLicense No. Version 3.0 (2017 LACBC)Dec. 8 2016 ONE STORY ADU UNIT Hong Chuen Chao909 680-2727 HONG CHUEN CHAO 5036 STEWART AVE. BALDWIN PARK CA 91706 boundary nail shall be staggered. typical. (reduced diameter nails prohibited) than 350 pounds/foot require a 3 inch nominal or greater member. The 3. Sill PL. & Studs @ edge of plywood for shear walls with lateral loads greater 5/8" Ø @ 32" o.c.16d @ 4" o.c.12668d15/32" STR'L I 5 4 3 2 12 12 12 1215/32" STR'L I 870 665 510 340 15/32" STR'L I 10d2 10d3 2 3 10d4 10d6 4 6 5/8" Ø @ 12" o.c. 5/8" Ø @ 16" o.c. 5/8" Ø @ 18" o.c. 5/8" Ø @ 28" o.c. 3/8" o L.G.@ 6"o.c. 20d @ 2 1/2"o.c. 20d @ 3" o.c. 16d @ 3" o.c. 1 MARKBOUND CAPACITY 280 #/LF 4 OR 5 LAY OR OSB PLYWOOD BOUND SPACING NAIL EDGE SILL BOLTSSILL NAIL 15/32" STR'L I 15/32" STR'L I SIMPSON A35 OR LPT4 TIE @ 16" O.C. @ 16" O.C. @ 16" O.C. @ 12" O.C. @ 8" O.C. SHEAR WALL SCHEDULE (All nails shall be common nails) 39 5 4 E . A T T T A L L A S T R E E T , O N T A R I O C A 9 1 7 6 1 (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST POST4X6POST POST4X6POST POST4X6POST POST4X6POST POST4X4POST POST4X4POST (E) CONCRETE FOOTING (E) CONCRETE FOOTING(E) CONCRETE FOOTING NEW FOOTING EXISTING FOOTING FOUNDATION PLAN SCALE:1/4"=1'-0" CONC. PAD SIZE REBAR A 24" X 24" DEPTH 24" CONCRETE PAD SCHEDULE 4-#5 REBAR EACH WAY FOOTING UNDERPIN DEPTH = "14" PAD A PAD AUNDERPIN RENOVATION AREAPAD AUNDERPINPAD AUNDERPIN S-111S-1 TYP. S-111S-1 TYP. S-1 11 S-1 S-1 11 S-1 S-12S-1TYP. S-12S-1 TYP.S-1 7 S-1S-17S-1 S-1 7 S-1 9. SEE DETAIL 1 THIS SHEET FOR REBAR AT CORNER AND INTERSECTION. (E) CONCRETE SLAB (E) CONCRETE SLAB (E) CONCRETE SLAB omissions noted on the drawings or in the specifications or any variations need 1. The Contractor shall inform the engineer in writing of any discrepancies or in order to conform to codes, rules and regulations. Upon receipt of such information, the engineer will send written instructions to all concerned. Any such discrepancy, omission, or variation not reported shall be the responsibility of contractor, and work shall be performed in a manner as directed by the engineer. shoring, bracing, and formwork, as required for protection of life and property 2. It shall be the contractor's sole responsibility to design and provide adequate before the demolition and during the construction of this building. Excess load exceed loads equivalent to the design superimposed loads dead and live loads. design superimposed loads include live load, partition load and any other load not in place at the time of shoring. NOTE: capacity of slab and roof/floor shall not less construction (E) EXISTING (N) NEW NOTE: PROVIDE LATICRETE HYDRO BAN WATER PROOFING (ICC ESR 2417) TWO LAYER ON TOP OF (E) CONCRETE SLAB OF THE RENOVATION AREA. 08/04/2024 GL 20240804 AR C A D I A , C A 9 1 0 0 6 12 2 C A L I F O R N I A S T R E E T LE G A L I Z I N G U N P E R M I T T E D N O N - L I V A B L E S P A C E IN T O A N A T T A C H E D A C C E S S O R Y D W E L L I N G U N I T SPECIAL INPECTION PROGRAM 1. The owner or the agent of the owner shall be responsible for employing the special inspector(s) as required by CBC Code SECTION 1701.1 for the construction project located at: 2. The following list of work (only checked items are required ) for Special Inspection: SOIL COMPLIANCE PRIOR TO FOUNDATION INSPECTION FIELD WELDING STRUCTURAL CONCRETE OVER 2500 PSI HIGH STRENGTH BOLTING PRESTRESSED / POSTENTION CONCRETE EXPANSION / EPOXY ANCHORS STRUCTURAL MASONRY SPRAYED-ON FIREPROOFING DESIGNER SPECIFIED OTHERS 3. Duties of the Special Inspector for the work listed above: A. B. C. D. SPECIAL INSPECTOR SHALL CHECK IN WITH THE CITY OR COUNTY AND PRESENT THEIR CREDENTIAL FOR APPROVAL PRIOR TO BEGINING WORK ON THE JOB. 122 CALIFORNIA STREET, ARCADIA CA 91006The Special Inspector shall inspect the foundation size, depth, grade beam rebar size, number, tie rebar and spacing, the anchor bolts size, embedment depth, the wood strong wall panels size, connection straps. SPECIAL INSPECTOR SHALL CHECK ALL SIMPSON WOOD STRONG WALL INSTALLATION following the details from the WSW plans and reference to ICC-ESR 2652 code report. CHECK SIMPSON SET XP ADHESIVE FOR ANCHOR BOLTS TO EXISING CONCRETE ACCORDING TO ICC-ESR 2508. S-4 DATE DRAWN SCALE JOB NO. DWG. NO. P.C. 1/4" = 1'-0" PE T E R C H A O & A S S O C I A T E S ST R U C T U R E D E S I G N C O N S U L T A N T TE L : ( 9 0 9 ) 6 8 0 - 2 7 2 7 L I NFORC VEATOFA C OI A G I L E N N E RE N AI E ES IGS RE E H D CGNO P R O TER U F CST I N S NO. C-68688 Exp.09/30/25 LI H HA O PE T E R C H A O & A S S O C I A T E S ST R U C T U R E D E S I G N C O N S U L T A N T L I NFORC V E AT OF A C OI A G I L E N N E RE N AI E ES IGS RE E H D CGNO P R O TER U F CS T I N S NO. C-68688 Exp.09/30/25 LI H HA O LEGEND: ALL HOLD-DOWNS AND POST ANCHORS SHALL BE INSTALLED ACCORDING TO SIMPSON STRONG TIE SPECIFICATIONS AND REQUIREMENTS OF ICBO REPORT # 1211 AND 4448 AND SHALL BE TIED IN PLACE PRIOR TO FOUNDATION INSPECTION. SPLICE PLATES OF EXTERIOR WALLS AND SHEAR WALLS W/(12) 16d AT 4'-0" SPLICE (U.O.N.). TYPICAL FLOOR SHEATHING USE 5/8" STRUCT. 1 T&G PLYWOOD P.I 32/16 WITH 10d COMMON NAILS AT 6"-6"-12" O/C, NAIL AND GLUE PLYWOOD TO FRAMING. LAY PERPENDICULAR TO FRAMING. TYPICAL ROOF SHEATHING: USE 1/2" STRUCT. 1 PLYWOOD, P.I. 24/0 WITH 10d COMMON NAILS AT 6"-6"-12" O/C LAY PERPENDICULAR TO FRAMING. USE 1X8 T&G SELECT SPRUCE AT EXPOSED EAVES, (U.O.N.). ALL DIMENSIONS SHOWN ON THE PLANS HAVE BEEN DETERMINED BY THE ARCHITECT. FRAMING NOTES 1. 6. 5. 2. 3. 4. PROVIDE MULTIPLE STUDS UNDER MULTIPLE JOISTS. STRUCTURAL WOOD PANEL SHEAR WALLS SHALL BE COVERED WITH MINIMUM 2 LAYERS 15# FELT UNDERLAYMENT PRIOR TO PLACING FINISH MATERIAL. 2- 2X OR 3X BLOCKING SHALL BE PROVIDED AT ALL HORIZONTAL JOINTS OCCURRING IN BRACED WALL PANELS.8. 7. ALL HOLD-DOWN ANCHOR NUTS SHALL BE TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. 9. 10. APPROVED PLATE WASHERS ARE REQUIRED ON OPPOSITE FOR ALL HOLD-DOWN CONNECTOR BOLTS INTO WOOD. THE FOLLOWING APPLIES TO ALL SHEAR WALLS WITH A SHEAR VALUE GREATER THAN 350 PLF. :11. a- PROVIDE 3x SILL PLATES FOR SILL THAT REST ON CONCRETE OR MASONRY. b- PROVIDE 3x STUDS AND BLOCKS BETWEEN ADJACENT PANELS. c- PROVIDE 1/2" EDGE DISTANCE FOR PLYWOOD BOUNDARY NAILING. d- Stagger nails if nail spacing is less than 2" o.c. e- SQUARE PLATE WASHERS SHALL BE USED WITH ALL ANCHOR BOLTS. 5/8" bolt dia- 3"x3"x0.229" 3/4" bolts dia- 3"x3"x5/16" 7/8" bolts dia- 3x3x3/8 1" bolts dia. --3.5x3.5x3/8 DIAMETER IS LIMITED TO 40% OF THE STUD/PLATE WIDTH IN ANY STUD ADN MAY BE 60% IN NONBEARING PARTITIONS OR WHEN THE BORED STUD IS DOUBLED. WHERE POST IS NOT CONTINUOUS BETWEEN FLOORS, PROVIDE FULL HEIGHT KING STUD EACH SIDE OF POST WITH 16d @12" O.C. 15. CUTTING OR NOTCHING OF WOOD STUDS OR PLATES SHALL NOT EXCEED 25% OF THE STUD/PLATE WIDTH IN EXTERIOR AND BEARING WALLS AND NOT TO EXCEED 40% OF THE STUD/PLATE WIDTH IN NONBEARING PARTITIONS. BORED HOLES 14. 13. 12. USE 2-2X BLOCKING OR 2-2X JOIST AT ALL DRAG STRAPS SEE S-1 FOR SHEAR WALL SCHEDULE. LOWER PLATE SPLICE. SEE DETAIL SEE STUD NOTCHING DETAIL. 17. PROVIDE MINIMUM 4'-0" APART FOR TOP PLATE SPLICE AND 16. USE 2X6 STUD FOR THE PLUMBING PIPE WHEN NECESSARY. 19. PLYWOOD SHALL HAVE FRAMING OR BLOCKING AT ALL EDGES OF ALL SHEETS IN SHEARWALLS 18. PROVIDE A MINIMUN OF TW0 ANCHOR BOLTS FOR EACH BOTTOM PLATE. WITH ONE BOLT LOCATED NOT MORE THAN 12" OR LESS THAN 7 BOLT DIAMETERS FROM EACH END OF THE PIECE. 20. ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED. 21. ALL BOLT BOLES SHALL BE DRILLED 1/32 TO 1/16" OVERSIZED. INSPECTOR TO VERIFY. 22. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM WITH T-23-11-H. 23. FASTENERS FOR PRESERVATIVE-TREATED WOOD SHALL BE HOT DIPPED ZINC-COATED GAVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. THE COATING WEIGHTS FOR ZINC-COATED FASTENERS SHALL BE ACCORDANCE WITH ASTM A 153. 24. ALL SHEAR WALL PLYWOOD SHOULD USE EXTERIOR GLUE. 25. WHERE TOP OR SOLE PLATE ARE CUT FOR PIPES. A METAL TIE MINIMUM 0.058 INCHES THICK AND 1-1/2" WIDE SHALL BE FASTENED ACROSS THE OPENING WITH (6) 16d NAILS MINIMUM EACH SIDE. 26. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORT. FLOOR SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM WITH TABLE 2304.7. 27. THE HOLE IN THE PLATE WASHER IS PERMITTED TO BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 316 IN. LARGER THAN THE BOLT DIAMETER AND A SLOT LENGTH NOT TO EXCEED 1-3/4", PROVIDE A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. 28. ENGINEERED WOOD PRODUCTS SUCH AS PREFABRICATED WOOD I-JOIST, STRUCTURAL GLUE-LAMINATED TIMBER, STRUCTURAL COMPOSITE LUMBER AND DESIGN TRUSSES SHALL NOT BE NOTCHED OR DRILLED EXCEPT WHERE PERMITTED BY MANUFACTURERS' RECOMMENDATIONS OR WHERE THE EFFECTS OF SUCH ALTERATIONS ARE SPECIFICALLY CONSIDERED IN DESIGN OF THE MEMBER BY A REGISTERED DESIGN PROFESSIONAL. boundary nail shall be staggered. typical. (reduced diameter nails prohibited) than 350 pounds/foot require a 3 inch nominal or greater member. The 3. Sill PL. & Studs @ edge of plywood for shear walls with lateral loads greater 5/8" Ø @ 32" o.c.16d @ 4" o.c.12668d15/32" STR'L I 5 4 3 2 12 12 12 1215/32" STR'L I 870 665 510 340 15/32" STR'L I 10d2 10d3 2 3 10d4 10d6 4 6 5/8" Ø @ 12" o.c. 5/8" Ø @ 16" o.c. 5/8" Ø @ 18" o.c. 5/8" Ø @ 28" o.c. 3/8" o L.G.@ 6"o.c. 20d @ 2 1/2"o.c. 20d @ 3" o.c. 16d @ 3" o.c. 1 MARKBOUND CAPACITY 280 #/LF 4 OR 5 LAY OR OSB PLYWOOD BOUND SPACING NAIL EDGE SILL BOLTSSILL NAIL 15/32" STR'L I 15/32" STR'L I SIMPSON A35 OR LPT4 TIE @ 16" O.C. @ 16" O.C. @ 16" O.C. @ 12" O.C. @ 8" O.C. SHEAR WALL SCHEDULE (All nails shall be common nails) Development 3 ft min. REBAR PER PLAN REBAR PER PLAN REINFORCEMENT AT FOOTING INTERSECTION AND CORNERS 2.A.B. INTO WOOD FRAMING REQUIRE 3"X3"X0.229" 3.PROVIDE 5/8" Ø A.B @ 42" O.C FOR NON SHEAR WALL . PLATE WASHERS FOR 5/8" Ø A.B. AND MIN 7" EMBEDMENT INTO CONC. SEE THE SHEAR WALL SCHEDULE TABLE ON S-1. SIZE & SPACING OF THE ANCHOR BOLT(A.B.). 1. FOLLOW THE SHEAR WALL SCHEDULE FOR THE FOUNDATION NOTE: 4. A MINIMUM TWO BOLTS PER PIECE OF SILL PLATE. 5. ALL HOLDOWN HARDWARE IS TO BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. 6.ONE LOCATED WITHIN 12" AND NOT LESS THAN 7 BOLT DIAMETER OR 4-3/8" OF EACH END OF EACH SILL PLATE. 7. FOUNDATION SILL PLATE SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. FIELD-CUT, NOTCHES AND DRILLED HOLES OF PRESERVATIVE-TREATED WOOD SHALL BE FIELD-TREATED PER AWPA M4. 8. SATURATE THE SOIL 24 INCH DEEP BEFORE PLACING THE CONCRETE SLAB. 9. THE HOLE IN THE PLATED WASHER IS PERMITTED TO BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 3 16 in. LARGER THAN THE BOLT DIAMETER AND A SLOT LENGTH NOT TO EXCEED 1- 3 4 in., PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. 10. FASTENERS FOR PRESERVATIVE-TREATED WOOD SHALL BE HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. THE COATING WEIGHTS FOR ZINC-COATED FASTENERS SHALL BE ACCORDANCE WITH ASTM A 153. FOOTING REBAR PER PLAN REBAR PER PLAN 39 5 4 E . A T T T A L L A S T R E E T , O N T A R I O C A 9 1 7 6 1 39 5 4 E . A T T T A L L A S T R E E T , O N T A R I O C A 9 1 7 6 1 (E ) 2 X 1 0 F L O O R J O I S T @ 1 6 " O . C . R E M A I N (E ) 2 X 1 0 F L O O R J O I S T @ 1 6 " O . C . R E M A I N (E ) 2 X 1 0 F L O O R J O I S T @ 1 6 " O . C . R E M A I N 4X4 4X4 (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E ) H D R (E ) H D R (E ) H D R (E ) H D R (E ) H D R (E ) H D R 4X4 (E ) G A R A G E H D R (E ) G A R A G E H D R (E ) G A R A G E H D R (E ) B E A M (E ) B E A M (E ) B E A M (E) STEEL COLUMN (E ) B E A M (E ) B E A M (E ) B E A M (E) BEAM FLOOR FRAMING PLAN SCALE:1/4"=1'-0" RENOVATION AREA G.L.B. 24F-V4 FB2 (E ) B E A M 1 (E ) B E A M 3 (E ) B E A M 2 (E) FLOOR JOIST (E) FLOOR JOIST (E) FLOOR JOIST P.A. P.A. P.A. P.A. P.A. POST ABOVE (concentrate load from above. include column, king post and shear wall end member uplift or downward force) (E) 2X10 NO.2 FLOOR JOIST @ 16" O.C. (E) POST (E ) H D R POST4X6POSTW/CCQ44 CAP POST4X6POSTW/CCQ44 CAP FB1 POST4X6POST POST4X6POST 5-1/2 X 9-1/2" POST4X6POSTW/CCQ44 CAP 4X10 NO.2 POST4X4POST POST4X4POST SIMPSONHU HANGER SIZE MATCH (E) BEAM SIMPSONHU HANGER SIZE MATCH (E) BEAM (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST (E) POST POST4X6POST POST4X6POST POST4X6POST POST4X6POST POST4X4POST POST4X4POST (E) CONCRETE FOOTING (E) CONCRETE FOOTING(E) CONCRETE FOOTING FOUNDATION PLAN SCALE:1/4"=1'-0" CONC. PAD SIZE REBAR A 24" X 24" DEPTH 24" CONCRETE PAD SCHEDULE 4-#5 REBAR EACH WAY FOOTING UNDERPIN DEPTH = "14" PAD A PAD AUNDERPIN RENOVATION AREAPAD AUNDERPINPAD AUNDERPIN 4" CONC. 2-#4 CONT. TOP & BOTTOM 3" MIN. 2X STUD@ 16" O.C INTO CONC. @ 48" O.C. TYP. U.N.O. PLATE WASHERS W/ 0.229" X 3" X 3" 2 x OR 3X P.T. SILL PL W/ 5/8" DIA. A.B X 12" SET 7" MIN. FOR CONCRETE GRADE BEAM COLD JOINTROUGH SURFACE(OPTION FOR TWO POUR) #4 DOWEL @ 16" EA.WAY 1-#4 REBAR 4" CONC. SLAB W/#4 REBAR @ 16" O.C. EA. WAY B.N. SHEAR WALL SHEATHINGWHERE OCCUR 12" OVER 15 MIL. MOISTURE BARRIER OVER 4" THICK BASEOF 1/2" OR LARGER CLEAN AGGREGATE SPECIAL INSPECTION IS REQUIRED. SIMPSON SET-XP STURCTURE EPOXY TIE (ICC ESR 2508)DRILL HOLE WITH 3/4" Ø. (E) FOOTING B.N. (E) 2X4 STUD WALL (N) SHEAR WALL SHEATHING 6" (N) 5/8" Ø ALL THREADED STEEL ROD ANCHOR BOLTANCHOR INTO EXISTING CONCRETE W/ 6" MIN. EMBEDMENT. W/ SIMPSON SET-XP ADHESIVEW/ THE SPACING PER SHEAR WALL W/ 3"X3"X0.229" STEEL PLATE WASHER WHEN EXISTING ANCHOR BOLTSPACING IN NOT ADEQUATE .WHERE OCCUR 26 GAGE WEEP SCREEN S-111S-1 TYP. S-1 11 S-1 TYP. S-111S-1 S-1 11 S-1 S-12S-1TYP. S-1 2 S-1 TYP.S-17S-1S-17S-1 S-17S-1 9. SEE DETAIL 1 THIS SHEET FOR REBAR AT CORNER AND INTERSECTION. (E) CONCRETE SLAB (E) CONCRETE SLAB (E) CONCRETE SLAB omissions noted on the drawings or in the specifications or any variations need 1. The Contractor shall inform the engineer in writing of any discrepancies or in order to conform to codes, rules and regulations. Upon receipt of such information, the engineer will send written instructions to all concerned. Any such discrepancy, omission, or variation not reported shall be the responsibility of contractor, and work shall be performed in a manner as directed by the engineer. shoring, bracing, and formwork, as required for protection of life and property 2. It shall be the contractor's sole responsibility to design and provide adequate before the demolition and during the construction of this building. Excess load exceed loads equivalent to the design superimposed loads dead and live loads. design superimposed loads include live load, partition load and any other load not in place at the time of shoring. NOTE: capacity of slab and roof/floor shall not less construction omissions noted on the drawings or in the specifications or any variations need 1. The Contractor shall inform the engineer in writing of any discrepancies or in order to conform to codes, rules and regulations. Upon receipt of such information, the engineer will send written instructions to all concerned. Any such discrepancy, omission, or variation not reported shall be the responsibility of contractor, and work shall be performed in a manner as directed by the engineer. shoring, bracing, and formwork, as required for protection of life and property 2. It shall be the contractor's sole responsibility to design and provide adequate before the demolition and during the construction of this building. Excess load exceed loads equivalent to the design superimposed loads dead and live loads. design superimposed loads include live load, partition load and any other load not in place at the time of shoring. NOTE: capacity of slab and roof/floor shall not less construction (E) EXISTING (N) NEW TYP. S-2 12 S-2 S-212S-2 S-2 13 S-2 TYP. S-213S-2 S-219BS-2 S-2 19B S-2 NOTE: PROVIDE LATICRETE HYDRO BAN WATER PROOFING (ICC ESR 2417) TWO LAYER ON TOP OF (E) CONCRETE SLAB OF THE RENOVATION AREA. AR C A D I A , C A 9 1 0 0 6 12 2 C A L I F O R N I A S T R E E T LE G A L I Z I N G U N P E R M I T T E D N O N - L I V A B L E S P A C E IN T O A N A T T A C H E D A C C E S S O R Y D W E L L I N G U N I T 08/04/2024 GL 20240804 AR C A D I A , C A 9 1 0 0 6 12 2 C A L I F O R N I A S T R E E T LE G A L I Z I N G U N P E R M I T T E D N O N - L I V A B L E S P A C E IN T O A N A T T A C H E D A C C E S S O R Y D W E L L I N G U N I T Structural Calculation For Legalizing Unpermitted Non-livable Space Into an Attached Access Dwelling Unit OF 122 California Street Arcadia, CA 91006 Exp.09/30/25 Peter Chao & Associates 3954 E. Attalla Street Ontario, CA 91761 (909) 680-2727 Table of Contents 1.Design Load 1. 2.Window and Door Header Design 2. 3.Floor Structural Members Design 3-15. 5.Lateral Analysis 16-23. 6. Foundation 24-25. 3.Wood Column Design 26.