Loading...
HomeMy WebLinkAbout617 S First AVe - 2024 - Tattoo ShopOf Sheets PR O J E C T : OW N E R : L.J & ASSOCIATE DESIGN Revisions By 6710 N. ROSEMEAD BL. SAN GABRIEL CA 91775 TEL: 626-833-0035 Date 3/25/2024 Scale Checked LIFU JUDrawn A - 1 EN G I N E E R : SE C R E T A R T S T U D I O 61 7 S . 1 S T . A V E AR C A D I A , C A 9 1 0 0 7 TE L : 6 2 6 - 2 7 2 - 6 4 0 4 SI T E P L A N ACCESSIBILITY DOOR DETAILS THIS PROJECT'S ALL DOORS MUST BE USED THE LEVER TYPE OF HARDWARE 5 LB. MAX. EFFORT TO OPERATE INTERIOR DOORS. 5 LB. MAX. EFFORT TO OPERATE EXTERIOR DOORS. 15 LB. MAX. EFFORT TO OPERATE FIRE DOORS. 3'-0" MIN. 6 - 8 " M I N . INSTALL OPERATING HARDWARE 34" TO 44" ABOVE FLOOR ACCESSIBLE DOOR OPERATING HARDWARE THRESHOLDS @DOORWAYS PUSH/PULLS LEVERS PANIC BARS SMOOTH SURFACES @DOORS MINIMUM CLEARANCES @DOORS 10" HIGH SMOOTH SURFACE SHALL BE PROVIDED ON THE "PUSH" SIDE OF THE DOOR PUSH HINGED DOOR 32" MIN. 32" 32" ALLOW CLEARANCE FOR PULL HANDLES ON DOOR FOLDING DOOR SLIDING DOOR 24 " MA X . MIN. MIN. DOOR FLOOR 2 1 1/2" max. @ 1:2 SLOPE 1/4" max. FIGURE 11A-1A INTERNATION (b) display conditions (a) symbol proportions Diagrams illustrate the specific these requirements and are intended only an aid for building design and constructi Diagram are not to scale. 7 5 4 EXITTACTILE EXIT SIGN6 48 " - 6 0 " TO B A S E LI N E O F T E X T GROUND SURFACE FINISH Division VII - FIGURES requirments of as on (2022 CBC). ACCESSIBILITY SYMBOL PARKING ONLY VAN ACCESSIBLE MINIMUM FINE $250 UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE TOWED VEHICLES MAY BE RECLAIMED AT OR BY TELEPHONING NOTE: THE ADDITIONAL "TOW-AWAY" LETTERS SHALL HAVE A MINIMUM HEIGHT OF 1" TOWING COMPANY'S NAME AND TELEPHONE NUMBERS MUST BE PROVIDED ON SIGN SIGN SHALL BE 17" MIN. X 22" MIN. 17" MIN. 22 " M I N . NOTE: SIGNS LOCATED W/IN A.F.F. OR ABOVE GROUND SURFACE. SIGNS MAY ALSO BE PERMANENTLY ACCESSIBLE ROUTE SHALL BE 80" MIN. 60 " M I N . POSTED ON A WALL AT THE INTERIOR END OF THE PARKING SPACE REFLECTORIZED WITH MINIMUM AREA OF 70 SQ.IN. GROUND SURFACE FINISH WHERE APPLIES 626-307-0062 0 NO PA R K I N G # 615# 617# 617-1/2# 619 # 615-1/2 8_(E) ACCESSIBLE PARKING TYP. (E) 70 SQ. INCH ACCESSIBILITY SIGN PER CODE TYP. W/VAN ACCESSIBLE SIGN W/MINIMUM FINE $250 _7 4" BLUE LINE BORDER 4" HATCHED DIAGONAL LINES AT 36" MAX. ON CENTER PAINTED A CONTRASTING COLOR WITH THE PARKING SURFACE WTITE ON AC BLUE ON CONCRETE ACCESS AISLE: MINIMUM WIDTH IS 5' FOR A REGULAR ACCESSIBLE PARKING STALL 8' FOR A VAN ACCESSIBLE PARKING STALL NO PARKING 9'-0" MIN. WHEEL STOP 45 O 3'-0" UNOBSTRUCTED AREA 18 ' - 0 " M I N . 4" B L U E L I N E ISA SYMBOL TYPICAL CL ACCESSIBILITY PARKING SIGN H/C PARKING DETAIL8 TYPE OF CONSTRUCTION: NUMBER OF STORY: TYP OF BUSINESS: FLOOR AREA:1245 S.F. V-B 1 OCCUPANCY TYPE:B FIRE SPRINKLERED:NO a) THE 2022 EDITION OF THE CALIFORNIA BUILDING CODE (CBC). b) THE 2022 EDITION OF THE CALIFORNIA ELECTRICAL CODE (CEC). c) THE 2022 EDITION OF THE CALIFORNIA MECHANICAL CODE (CMC). d) THE 2022 EDITION OF THE CALIFORNIA PLUMBING CODE (CPC). f) THE 2022 EDITION OF THE CALIFORNIA GREEN BUILDING STANDARDS CODE. g) THE 2022 EDITION OF THE CALIFORNIA ENERGY STANDARDS. e) THE 2022 EDITION OF THE CALIFORNIA FIRE CODE (CFC). OCCUPANCY LOAD:1245 S.F. 100 S.F.= 12 OCC. BUSINESS NAME: JOB ADDRESS: SECRET ART STUDIO 617 S 1ST. AVE BODY TATTOO A-1 SITE & DETAIL PLAN A-2 FLOOR PLAN h) CITY OF SAN GABRIEL MUNICIPAL CODE. ARCADIA, CA 91006 CE I L I N G DRY WALL CEILING RO O M S SEMI GLOSS ENAMEL PAINT SEE NOTE 1 WASHABLE SMOOTH "T" BAR CEILING PANEL "USG" GYPSUM, WHITE VINYL 2x4 OR 2x2 ACOUSTIC CLG PANEL CERAMIC TILE (SMOOTH, NON-SLIP) HARD WOOD FLOOR VINYL TILE 12"x12" SHEET VINYL FLOOR (CONTINUE) EXISTING CONC. FL. METAL FLOOR (FOR WALK-IN FREEZER) WA L L SEMI GLOSS ENAMEL PAINT SEE NOTE #1 WASHABLE SMOOTH CEREMIC TILE TO CEILING FL O O R QUARRY TILE (SMOOTH, NON-SLIP) "USA" DRY WALL (GYPSUM BD.) WITH PAINT CO V E D B A S E QUARRY TILE 6"H.(SMOOTH) "USA" CERAMIC TILE 6"H. (CONTINUE) 1) w a l l a n d c e i l l i n g s a l l a r e a s s h a l l b e d u r a b l e , s m o o t h , a n d n o n a b s o r b e n t , w i t h a l i g h t c o l o r e d ( l i g h t c o l o r e d i s d e f i n e d a s h a v i n g a l i g h t r e f l e c t a n c e v a l u e o f 7 0 % o r g r e a t e r ) e a s i l y c l e a n a b l e , w a s h a b l e f i n i s h . NO T E FINISH SCHEDULE SE R V I C E H A L L RE S T R O O M . WA I T I N G R M RE C E P T I O N CEREMIC TILE 4'H (SHOWER RM TILE 80"H) ST O R A G E 1. CHANGE USE FROM BEAUTY SALON TO A TATTOO SERVICE SHOP. 2. BUILD A NEW RESTROOM (61 S.F.) TO MEET "ADA" STANDARD. 3. KEEP ALL OTHER EQUIPMENTS (EXISTING A/C, ELECTRIC & MECHANICAL). A-3 EXISTING ELECTRICAL & VENTILATION PLAN ARIETYV P-1 PLUMBING PLAN P-2 PLUMBING PLAN Of Sheets PR O J E C T : OW N E R : L.J & ASSOCIATE DESIGN Revisions By 6710 N. ROSEMEAD BL. SAN GABRIEL CA 91775 TEL: 626-833-0035 Date 3/25/2024 Scale Checked 1/4"=1'-0" LIFU JUDrawn A - 2 EN G I N E E R : SE C R E T A R T S T U D I O 61 7 S . 1 S T . A V E AR C A D I A , C A 9 1 0 0 7 TE L : 6 2 6 - 2 7 2 - 6 4 0 4 FL O O R P L A N SC : 1/4"=1'-0"FLOOR PLAN CLR. SPACE30 " PO R T A B L E C O U N T E R 34 " H 48" WH 1 2 3 CHAIR NO DESCRIPTION ALL EQUIPMENTS MEET NSF STANDARSQUA 2 2 2 TOOLS CASE WALL MOUNTED FIRE EX. (2A10BC) PER 2022 CBC EXIST'G WALL NEW WALL 2x4 STUD @ 16"O.C. .')'0& FILL EXIST'G DOOR OR WINDOW REMOVE NON-BEARING WALL 1 2 3 TATTOO TABLE, BED CHAIR 1 2 3 EXIT 2 FRONT & SIDE ELEVATION 1 PICTORIAL SIGNAGE GRADE 2 BRAILLE 58 " - 6 0 " T O C O F 48 " - 6 0 " TO B A S E LI N E O F TE X T SY M B O L L RESTROOM 12 " RESTROOMS (UNISEX) 12"24" min.min. 36" min. GRAB BAR 33 " m i n . mi n . 36" min. 19 " 33 " m i n . T O 3 6 " m a x . min.48" _ A 7"-9" 12"42" min. max.GRAB BAR 54" min. 17 " - 1 9 " A NOMINAL DIAMETER 1-1/4" min. TO 2" max. WALL 1-1/2" 17" min. FLUSH HANDLE SIDE 24" min. GRAB BAR SECTION ALL DISPENSERS +40" MAX TO HIGHEST OPERABLE PART GRAB BAR 18" max. 36 " m a x . 1 _ 42" MIN._ 2 GRAB BAR _ KNEE & TOE SPACE FOR SINK AND MIRROR3 40 " M A X . MIRROR LOCATION 9" M I N . 27 " M I N . 29 " M I N . 34 " M I N . TOE CLEARANCE 6" MAX. 17" MIN. 8" MAX. KNEECLEARANCE If a min. 9" height of toe clearance is provided, a max. of 6" of the 48" of clear floor space required at the fixture may extend into the toe space. 18 " M I N . 17" MIN. CLEAR FLOOR SPACE30 " M I N . 48" MIN. 19" MAX. CL 3_ ON THE LATCH SIDE OF DISABLED ACCESS : W/"TACTILE EXIT SIGN" EXIT DOOR" 6 A-1 5 A-1 ENTRANCE SIGN PER 2022 CBC EXIT DOOR IS RODENT SELF-CLOSING. PROOF, TIGHT FITTING, EXISTING DOOR 6'W 6'-8"H IS SMOOTH, & PLANE SURFACE THE DOOR OF LOWER 10" 43"H ABOVE THE FLOOR HARDWARE MOUNTED THAN 1/2"ABOVE THE FLOOR THRESHOLD NO HIGHER NO MORE THAN 1/4" GAP AROUND THE PERIMETER OF THE DOOR 4 A-1 4 A-1 ENTRANCE SIGN PER 2022 CBC THAN 1/2"ABOVE THE FLOOR THRESHOLD NO HIGHER 4 A-14 A-1 5 A-1 ON THE LATCH SIDE OF DISABLED ACCESS : W/"TACTILE EXIT SIGN" EXIT DOOR" EXIT DOOR IS RODENT SELF-CLOSING. PROOF, TIGHT FITTING, EXISTING DOOR 4'-6"W 6'-8"H IS SMOOTH, & PLANE SURFACE THE DOOR OF LOWER 10" 43"H ABOVE THE FLOOR HARDWARE MOUNTED NO MORE THAN 1/4" GAP AROUND THE PERIMETER OF THE DOOR EXIT ARIETYV A-A SHOWER RM SECTION DETAIL 7'-10" 7'- 1 0 " A _ A _ NEW 2x4 STUD WALL CE I L I N G H I G H TILE FLOOR (E) CONC. SLAB FLOOR 6'-8"H ABOVE THE FLOOR TILE WALL COVERING 6"H TILE COUPING CONTINUE TYP. 1% SLOPE TO DRAIN 2x4 PRESURE TREATED SILL PLATE 8'- 0 " EXISTING STUD WALL 8" WATER PROOF'G (HOT MOPPING) ON FLOOR AND UP 8" ON THE WALLS D_WALL WATER PROOF'G DETAIL ON SHOWER WALL 2x6 WD. STUD C. J. @ 16" O.C. TYP. 2x6 LEDGER W/1/2"x5" LAG BOLT TO EA. STUDTYP. 5/8" WATER RESISTANT GYPSUM BOARD 2x4 PRESURE TREATED SILL PLATE SIMPSON STRONG-TIE ANCHOR LENGTH: 3" DIAMETER: 5/16" MIN. EMBEDMENT SPACING: @32" O.C. DEPTH: 1-1/2" (ICC-ESR-1771) WALL WALL TILE D WALL WATERPROOF'G DETAIL (ON SHOWER AREA) W/A FIBERGLASS TAPE AT JOINT TWO-COATS OF FLEXIBLE WATER PROOFING COMPOUND "EXIT" SIGN BACK-UP POWER 90 MINUTES MIN. TYP. SIGN ABOVE THE DOOR. PROVIDE ILLUMINATED 4'-0" 5'-10" 3'- 0 " 4'- 0 " 5' - 2 " 4'- 8 " 21'-7" 17 ' - 5 " 10 ' - 2 " 7'-6"4'-5" 23 ' - 1 " 15 ' - 9 " 32 ' - 1 1 " 15'-8" 48" MIN. 5'- 0 " M I N . 1' - 6 " mi n . 1' - 6 " mi n . 3_ Of Sheets PR O J E C T : OW N E R : L.J & ASSOCIATE DESIGN Revisions By 6710 N. ROSEMEAD BL. SAN GABRIEL CA 91775 TEL: 626-833-0035 Date 3/25/2024 Scale Checked 1/4"=1'-0" LIFU JUDrawn A - 3 EN G I N E E R : SE C R E T A R T S T U D I O 61 7 S . 1 S T . A V E AR C A D I A , C A 9 1 0 0 7 TE L : 6 2 6 - 2 7 2 - 6 4 0 4 EX I S T I N G E L E C T R I C A L & V E N T I L A T I O N P L A N SC : 1/4"=1'-0" 1. ALL ELECTRICAL LIGHTS ARE EXISTING UNLESS SHOWN OTHERWISE. 2. NO MORE THAN 48-INCHES, MEASURED FROM THE TOP OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING. 3. OUTLETS TO BE A MIN. OF 15-INCHES ABOVE FINISHED FLOOR. 2X4' FLUORESCENT TUBE (40 LUMONS PER WATT) REFLECTED CEILING LEGEND ( ELECTRICAL PLAN ) LIGHT W/EXHAUST FAN NOTE NEW EXISTING OUTLET @ 15" ABOVE FLOOR 2'x4' T- BAR CEILING EXISTING 3. THE MIN. RATE OF OUTDOOR AIR FOR MECHANICALLY VENTILATION SPACES SHALL BE SUPPLIED TO EACH SPACE AT ALL TIMES WHEN THE SPACE IS USUALLY OCCUPIED. 4. MECHANICALLY VENTILATED CAPABLE OF PROVIDING AN OUTDOOR AIR RATE NO LESS 15 CFM PER PERSON. 1. ALL VENTILATION SYSTEM ON THE CEILING ARE EXISTING. 2. SUSPENDED CEILINGS ARE EXISTING. REFLECTED CEILING LEGEND ( VENTILATION PLAN ) 2'x4' T- BAR CEILING (FAN - 50 CFM MIN. PER TABLE 4-4 CMC) LIGHT W/EXHAUST FAN 2'x2' AIR RETURN VENT 2'x2' AIR SUPPLY VENT NOTE EXISTING EXISTING NEW EXISTING SC : 1/4"=1'-0" EXIT EMERGENCY BACK-UP LIGHTING (POWER 90 MIN.)NEW EXIT EXIT ARIETYV EXISTING PIPE MATERIALS SERVICES LOCATION MATERIAL JOINING METHOD REMARKS DOMESTIC COLD & HOT WATER UNDERGROUND RIGID COPPER( TYPE K)BRAZED NOT TO EXCEED 20 OF I PERCENT JOINT FITTINGS. SHOULD STREET PRESSURE EXCEED 80 PSI, A PRESSURE REDUCING VALVE ASSEMBLY SHALL BE INSTALLED. NO JOINTS SHALL BE ALLOWED UNDER BUILDING SLAB. GATE VALVES SHALL BE BRONZE WITH ENDS TO SUITE PIPE, NONRISING STEM FOR 150 PSI WORKING PRESSURE. ABOVE UNDERGROUND RIGID COPPER( TYPE L)SOLDERED SANITARY WASTE SEWER UNDERGROUND CAST IRON SOIL PIPE & FITTINGS OR OTHER APPROVED MATERIAL HUBLESS ABOVE GROUND CAST IRON SOIL PIPE & FITTINGS OR OTHER APPROVED MATERIAL HUBLESS SANITARY WASTE VENT ABOVE GROUND CAST IRON SOIL PIPE & FITTINGS OR OTHER APPROVED MATERIAL HUBLESS LOW PRESSURE GAS UNDERGROUND SCHEDULE 40 BLACK STEEL WELDED PROVEIDE APPROVED GAS PRESSUSRE REGULATORS. NATURAL GAS RIGHT AND LEFT HAND NIPPLES AND COUPLINGS SHALL BE NEW BLACK IRON, UNIONS SHALL NOT BE USED EXCEPT AT UNITS AND VAVLES. ABOVE UNDERGROUND SCHEDULE 40 BLACK STEEL WELDED ABS PIPE MAY BE USED WHEN FIRST APPROVED BY THE ADMINISTRATIVE AUTHORITY ABS PIPE MAY BE USED WHEN FIRST APPROVED BY THE ADMINISTRATIVE AUTHORITY ABS PIPE MAY BE USED WHEN FIRST APPROVED BY THE ADMINISTRATIVE AUTHORITY PLUMBING ABBREVIATIONSPLUMBING LEGENDMEP COMPONENT ANCHORAGE NOTE PIPING SYSTEM BRACING NOTE GENERAL NOTES DOMESTIC WATER PIPING SIZING DOMESTIC WATER CALCULATION FIXTURE CONNECTION SCHEDULE (BRANCH SIZES) MISC. EQUIPMENT SCHEDULE REVISIONS J S E N G I N E E R I N G , I N C . STAMP P1 61 7 S . 1 S T . A V E . , A R C A D I A , C A . 9 1 0 0 7 TE N A N T I M P R O V E M E N T - SE C R E T A R T S T U D I O LEGEND CHAIR NO DESCRIPTION QUA 2 2 2 TOOLS CASE EXIT EXIT W H EXIT EXIT W H EXIT EXIT FLOOR PLAN (HOT & COLD) 1/4"=1'-0" FLOOR PLAN (WASTE & VENT) 1/4"=1'-0" FLOOR PLAN (GAS) 1/4"=1'-0" REVISIONS J S E N G I N E E R I N G , I N C . STAMP P2 61 7 S . 1 S T . A V E . , A R C A D I A , C A . 9 1 0 0 7 TE N A N T I M P R O V E M E N T - SE C R E T A R T S T U D I O