HomeMy WebLinkAbout617 S First AVe - 2024 - Tattoo ShopOf Sheets
PR
O
J
E
C
T
:
OW
N
E
R
:
L.J & ASSOCIATE DESIGN
Revisions By
6710 N. ROSEMEAD BL.
SAN GABRIEL CA 91775
TEL: 626-833-0035
Date 3/25/2024
Scale
Checked
LIFU JUDrawn
A - 1
EN
G
I
N
E
E
R
:
SE
C
R
E
T
A
R
T
S
T
U
D
I
O
61
7
S
.
1
S
T
.
A
V
E
AR
C
A
D
I
A
,
C
A
9
1
0
0
7
TE
L
:
6
2
6
-
2
7
2
-
6
4
0
4
SI
T
E
P
L
A
N
ACCESSIBILITY DOOR DETAILS
THIS PROJECT'S ALL DOORS
MUST BE USED THE LEVER
TYPE OF HARDWARE
5 LB. MAX. EFFORT TO OPERATE INTERIOR DOORS.
5 LB. MAX. EFFORT TO OPERATE EXTERIOR DOORS.
15 LB. MAX. EFFORT TO OPERATE FIRE DOORS.
3'-0" MIN.
6
-
8
"
M
I
N
.
INSTALL OPERATING
HARDWARE 34" TO 44"
ABOVE FLOOR
ACCESSIBLE DOOR OPERATING HARDWARE
THRESHOLDS @DOORWAYS
PUSH/PULLS
LEVERS
PANIC BARS
SMOOTH SURFACES @DOORS MINIMUM CLEARANCES @DOORS
10" HIGH SMOOTH SURFACE SHALL BE
PROVIDED ON THE "PUSH" SIDE OF THE DOOR
PUSH
HINGED DOOR
32"
MIN.
32"
32"
ALLOW CLEARANCE FOR
PULL HANDLES ON DOOR
FOLDING DOOR
SLIDING DOOR
24
"
MA
X
.
MIN.
MIN.
DOOR
FLOOR 2 1 1/2" max.
@ 1:2 SLOPE
1/4" max.
FIGURE 11A-1A INTERNATION
(b) display conditions
(a) symbol proportions
Diagrams illustrate the specific
these requirements and are intended only
an aid for building design and constructi
Diagram are not to scale.
7
5
4
EXITTACTILE
EXIT SIGN6
48
"
-
6
0
"
TO
B
A
S
E
LI
N
E
O
F
T
E
X
T
GROUND SURFACE FINISH
Division VII - FIGURES
requirments of
as
on
(2022 CBC).
ACCESSIBILITY SYMBOL
PARKING
ONLY
VAN ACCESSIBLE
MINIMUM FINE $250
UNAUTHORIZED VEHICLES
PARKED IN DESIGNATED
ACCESSIBLE SPACES NOT
DISPLAYING DISTINGUISHING
PLACARDS OR SPECIAL
LICENSE PLATES ISSUED FOR
PERSONS WITH DISABILITIES
WILL BE TOWED AWAY AT
THE OWNER'S EXPENSE
TOWED VEHICLES MAY BE
RECLAIMED AT
OR BY TELEPHONING
NOTE: THE ADDITIONAL "TOW-AWAY"
LETTERS SHALL HAVE A MINIMUM
HEIGHT OF 1"
TOWING COMPANY'S NAME AND
TELEPHONE NUMBERS MUST BE
PROVIDED ON SIGN
SIGN SHALL BE 17" MIN. X 22" MIN.
17" MIN.
22
"
M
I
N
.
NOTE: SIGNS LOCATED W/IN
A.F.F. OR ABOVE GROUND SURFACE.
SIGNS MAY ALSO BE PERMANENTLY
ACCESSIBLE ROUTE SHALL BE 80" MIN.
60
"
M
I
N
.
POSTED ON A WALL AT THE INTERIOR
END OF THE PARKING SPACE
REFLECTORIZED
WITH MINIMUM AREA
OF 70 SQ.IN.
GROUND SURFACE FINISH
WHERE APPLIES 626-307-0062
0
NO
PA
R
K
I
N
G
# 615# 617# 617-1/2# 619
# 615-1/2
8_(E) ACCESSIBLE PARKING
TYP.
(E) 70 SQ. INCH ACCESSIBILITY
SIGN PER CODE TYP.
W/VAN ACCESSIBLE SIGN
W/MINIMUM FINE $250
_7
4" BLUE LINE BORDER
4" HATCHED DIAGONAL LINES
AT 36" MAX. ON CENTER
PAINTED A CONTRASTING
COLOR WITH THE PARKING
SURFACE WTITE ON AC
BLUE ON CONCRETE
ACCESS AISLE: MINIMUM
WIDTH IS 5' FOR A REGULAR
ACCESSIBLE PARKING STALL
8' FOR A VAN ACCESSIBLE
PARKING STALL
NO
PARKING
9'-0" MIN.
WHEEL STOP
45 O
3'-0"
UNOBSTRUCTED
AREA
18
'
-
0
"
M
I
N
.
4"
B
L
U
E
L
I
N
E
ISA SYMBOL
TYPICAL
CL
ACCESSIBILITY
PARKING SIGN
H/C PARKING DETAIL8
TYPE OF CONSTRUCTION:
NUMBER OF STORY:
TYP OF BUSINESS:
FLOOR AREA:1245 S.F.
V-B
1
OCCUPANCY TYPE:B
FIRE SPRINKLERED:NO
a) THE 2022 EDITION OF THE CALIFORNIA BUILDING CODE (CBC).
b) THE 2022 EDITION OF THE CALIFORNIA ELECTRICAL CODE (CEC).
c) THE 2022 EDITION OF THE CALIFORNIA MECHANICAL CODE (CMC).
d) THE 2022 EDITION OF THE CALIFORNIA PLUMBING CODE (CPC).
f) THE 2022 EDITION OF THE CALIFORNIA GREEN BUILDING STANDARDS CODE.
g) THE 2022 EDITION OF THE CALIFORNIA ENERGY STANDARDS.
e) THE 2022 EDITION OF THE CALIFORNIA FIRE CODE (CFC).
OCCUPANCY LOAD:1245 S.F.
100 S.F.= 12 OCC.
BUSINESS NAME:
JOB ADDRESS:
SECRET ART STUDIO
617 S 1ST. AVE
BODY TATTOO
A-1 SITE & DETAIL PLAN
A-2 FLOOR PLAN
h) CITY OF SAN GABRIEL MUNICIPAL CODE.
ARCADIA, CA 91006
CE
I
L
I
N
G
DRY WALL CEILING
RO
O
M
S
SEMI GLOSS ENAMEL PAINT SEE NOTE 1
WASHABLE SMOOTH
"T" BAR CEILING PANEL
"USG" GYPSUM, WHITE VINYL
2x4 OR 2x2 ACOUSTIC CLG PANEL
CERAMIC TILE (SMOOTH, NON-SLIP)
HARD WOOD FLOOR
VINYL TILE 12"x12"
SHEET VINYL FLOOR (CONTINUE)
EXISTING CONC. FL.
METAL FLOOR (FOR WALK-IN FREEZER)
WA
L
L
SEMI GLOSS ENAMEL PAINT SEE NOTE #1
WASHABLE SMOOTH
CEREMIC TILE TO CEILING
FL
O
O
R
QUARRY TILE (SMOOTH, NON-SLIP) "USA"
DRY WALL (GYPSUM BD.) WITH PAINT
CO
V
E
D
B
A
S
E
QUARRY TILE 6"H.(SMOOTH) "USA"
CERAMIC TILE 6"H. (CONTINUE)
1)
w
a
l
l
a
n
d
c
e
i
l
l
i
n
g
s
a
l
l
a
r
e
a
s
s
h
a
l
l
b
e
d
u
r
a
b
l
e
,
s
m
o
o
t
h
,
a
n
d
n
o
n
a
b
s
o
r
b
e
n
t
,
w
i
t
h
a
l
i
g
h
t
c
o
l
o
r
e
d
(
l
i
g
h
t
c
o
l
o
r
e
d
i
s
d
e
f
i
n
e
d
a
s
h
a
v
i
n
g
a
l
i
g
h
t
r
e
f
l
e
c
t
a
n
c
e
v
a
l
u
e
o
f
7
0
%
o
r
g
r
e
a
t
e
r
)
e
a
s
i
l
y
c
l
e
a
n
a
b
l
e
,
w
a
s
h
a
b
l
e
f
i
n
i
s
h
.
NO
T
E
FINISH SCHEDULE
SE
R
V
I
C
E
H
A
L
L
RE
S
T
R
O
O
M
.
WA
I
T
I
N
G
R
M
RE
C
E
P
T
I
O
N
CEREMIC TILE 4'H (SHOWER RM TILE 80"H)
ST
O
R
A
G
E
1. CHANGE USE FROM BEAUTY SALON TO A TATTOO SERVICE SHOP.
2. BUILD A NEW RESTROOM (61 S.F.) TO MEET "ADA" STANDARD.
3. KEEP ALL OTHER EQUIPMENTS (EXISTING A/C, ELECTRIC & MECHANICAL).
A-3 EXISTING ELECTRICAL & VENTILATION PLAN
ARIETYV
P-1 PLUMBING PLAN
P-2 PLUMBING PLAN
Of Sheets
PR
O
J
E
C
T
:
OW
N
E
R
:
L.J & ASSOCIATE DESIGN
Revisions By
6710 N. ROSEMEAD BL.
SAN GABRIEL CA 91775
TEL: 626-833-0035
Date 3/25/2024
Scale
Checked
1/4"=1'-0"
LIFU JUDrawn
A - 2
EN
G
I
N
E
E
R
:
SE
C
R
E
T
A
R
T
S
T
U
D
I
O
61
7
S
.
1
S
T
.
A
V
E
AR
C
A
D
I
A
,
C
A
9
1
0
0
7
TE
L
:
6
2
6
-
2
7
2
-
6
4
0
4
FL
O
O
R
P
L
A
N
SC : 1/4"=1'-0"FLOOR PLAN
CLR.
SPACE30
"
PO
R
T
A
B
L
E
C
O
U
N
T
E
R
34
"
H
48"
WH
1
2
3
CHAIR
NO
DESCRIPTION
ALL EQUIPMENTS MEET NSF STANDARSQUA
2
2
2 TOOLS CASE
WALL MOUNTED
FIRE EX. (2A10BC)
PER 2022 CBC
EXIST'G WALL
NEW WALL 2x4 STUD @ 16"O.C.
.')'0&
FILL EXIST'G DOOR OR WINDOW
REMOVE NON-BEARING WALL
1
2
3
TATTOO TABLE, BED CHAIR
1
2
3
EXIT
2 FRONT & SIDE ELEVATION
1 PICTORIAL SIGNAGE
GRADE 2 BRAILLE
58
"
-
6
0
"
T
O
C
O
F
48
"
-
6
0
"
TO
B
A
S
E
LI
N
E
O
F
TE
X
T
SY
M
B
O
L
L
RESTROOM
12
"
RESTROOMS
(UNISEX)
12"24"
min.min.
36" min.
GRAB BAR
33
"
m
i
n
.
mi
n
.
36" min.
19
"
33
"
m
i
n
.
T
O
3
6
"
m
a
x
.
min.48"
_
A
7"-9"
12"42" min.
max.GRAB BAR
54" min.
17
"
-
1
9
"
A
NOMINAL DIAMETER
1-1/4" min. TO 2" max.
WALL
1-1/2"
17" min.
FLUSH HANDLE
SIDE
24" min.
GRAB BAR SECTION
ALL DISPENSERS
+40" MAX TO
HIGHEST OPERABLE
PART
GRAB BAR
18" max.
36
"
m
a
x
.
1
_
42" MIN._
2
GRAB BAR
_
KNEE & TOE SPACE FOR
SINK AND MIRROR3
40
"
M
A
X
.
MIRROR
LOCATION
9"
M
I
N
.
27
"
M
I
N
.
29
"
M
I
N
.
34
"
M
I
N
.
TOE CLEARANCE
6" MAX.
17" MIN.
8" MAX.
KNEECLEARANCE
If a min. 9" height of toe clearance
is provided, a max. of 6" of the 48"
of clear floor space required at the
fixture may extend into the toe space.
18
"
M
I
N
.
17" MIN.
CLEAR
FLOOR
SPACE30
"
M
I
N
.
48" MIN.
19" MAX.
CL
3_
ON THE LATCH SIDE OF
DISABLED ACCESS :
W/"TACTILE EXIT SIGN"
EXIT DOOR"
6
A-1
5
A-1
ENTRANCE SIGN
PER 2022 CBC EXIT DOOR IS RODENT
SELF-CLOSING.
PROOF, TIGHT FITTING,
EXISTING DOOR 6'W 6'-8"H
IS SMOOTH, & PLANE SURFACE
THE DOOR OF LOWER 10"
43"H ABOVE THE FLOOR
HARDWARE MOUNTED
THAN 1/2"ABOVE THE FLOOR
THRESHOLD NO HIGHER
NO MORE THAN 1/4" GAP
AROUND THE PERIMETER
OF THE DOOR
4
A-1
4
A-1
ENTRANCE SIGN
PER 2022 CBC
THAN 1/2"ABOVE THE FLOOR
THRESHOLD NO HIGHER
4
A-14
A-1
5
A-1
ON THE LATCH SIDE OF
DISABLED ACCESS :
W/"TACTILE EXIT SIGN"
EXIT DOOR"
EXIT DOOR IS RODENT
SELF-CLOSING.
PROOF, TIGHT FITTING,
EXISTING DOOR 4'-6"W 6'-8"H
IS SMOOTH, & PLANE SURFACE
THE DOOR OF LOWER 10"
43"H ABOVE THE FLOOR
HARDWARE MOUNTED
NO MORE THAN 1/4" GAP
AROUND THE PERIMETER
OF THE DOOR
EXIT
ARIETYV
A-A SHOWER RM SECTION DETAIL
7'-10"
7'-
1
0
"
A
_
A
_
NEW 2x4
STUD WALL
CE
I
L
I
N
G
H
I
G
H
TILE FLOOR
(E) CONC. SLAB FLOOR
6'-8"H ABOVE THE FLOOR
TILE WALL COVERING
6"H TILE COUPING
CONTINUE TYP.
1% SLOPE TO DRAIN
2x4 PRESURE TREATED
SILL PLATE
8'-
0
"
EXISTING
STUD WALL
8"
WATER PROOF'G (HOT MOPPING)
ON FLOOR AND UP 8" ON THE WALLS
D_WALL WATER
PROOF'G DETAIL
ON SHOWER WALL
2x6 WD. STUD C. J.
@ 16" O.C. TYP.
2x6 LEDGER W/1/2"x5"
LAG BOLT TO EA. STUDTYP.
5/8" WATER RESISTANT
GYPSUM BOARD
2x4 PRESURE TREATED
SILL PLATE
SIMPSON STRONG-TIE
ANCHOR LENGTH: 3"
DIAMETER: 5/16"
MIN. EMBEDMENT
SPACING: @32" O.C.
DEPTH: 1-1/2"
(ICC-ESR-1771)
WALL
WALL TILE
D WALL WATERPROOF'G DETAIL
(ON SHOWER AREA)
W/A FIBERGLASS TAPE AT JOINT
TWO-COATS OF FLEXIBLE
WATER PROOFING COMPOUND
"EXIT" SIGN BACK-UP
POWER 90 MINUTES MIN. TYP.
SIGN ABOVE THE DOOR.
PROVIDE ILLUMINATED
4'-0"
5'-10"
3'-
0
"
4'-
0
"
5'
-
2
"
4'-
8
"
21'-7"
17
'
-
5
"
10
'
-
2
"
7'-6"4'-5"
23
'
-
1
"
15
'
-
9
"
32
'
-
1
1
"
15'-8"
48" MIN.
5'-
0
"
M
I
N
.
1'
-
6
"
mi
n
.
1'
-
6
"
mi
n
.
3_
Of Sheets
PR
O
J
E
C
T
:
OW
N
E
R
:
L.J & ASSOCIATE DESIGN
Revisions By
6710 N. ROSEMEAD BL.
SAN GABRIEL CA 91775
TEL: 626-833-0035
Date 3/25/2024
Scale
Checked
1/4"=1'-0"
LIFU JUDrawn
A - 3
EN
G
I
N
E
E
R
:
SE
C
R
E
T
A
R
T
S
T
U
D
I
O
61
7
S
.
1
S
T
.
A
V
E
AR
C
A
D
I
A
,
C
A
9
1
0
0
7
TE
L
:
6
2
6
-
2
7
2
-
6
4
0
4
EX
I
S
T
I
N
G
E
L
E
C
T
R
I
C
A
L
&
V
E
N
T
I
L
A
T
I
O
N
P
L
A
N
SC : 1/4"=1'-0"
1. ALL ELECTRICAL LIGHTS ARE EXISTING UNLESS SHOWN OTHERWISE.
2. NO MORE THAN 48-INCHES, MEASURED FROM THE TOP OF THE RECEPTACLE
OUTLET BOX OR RECEPTACLE HOUSING.
3. OUTLETS TO BE A MIN. OF 15-INCHES ABOVE FINISHED FLOOR.
2X4' FLUORESCENT TUBE (40 LUMONS PER WATT)
REFLECTED CEILING LEGEND
( ELECTRICAL PLAN )
LIGHT W/EXHAUST FAN
NOTE
NEW
EXISTING
OUTLET @ 15" ABOVE FLOOR
2'x4' T- BAR CEILING EXISTING
3. THE MIN. RATE OF OUTDOOR AIR FOR MECHANICALLY VENTILATION
SPACES SHALL BE SUPPLIED TO EACH SPACE AT ALL TIMES WHEN THE
SPACE IS USUALLY OCCUPIED.
4. MECHANICALLY VENTILATED CAPABLE OF PROVIDING AN OUTDOOR AIR RATE
NO LESS 15 CFM PER PERSON.
1. ALL VENTILATION SYSTEM ON THE CEILING ARE EXISTING.
2. SUSPENDED CEILINGS ARE EXISTING.
REFLECTED CEILING LEGEND
( VENTILATION PLAN )
2'x4' T- BAR CEILING
(FAN - 50 CFM MIN. PER TABLE 4-4 CMC)
LIGHT W/EXHAUST FAN
2'x2' AIR RETURN VENT
2'x2' AIR SUPPLY VENT
NOTE
EXISTING
EXISTING
NEW
EXISTING
SC : 1/4"=1'-0"
EXIT EMERGENCY BACK-UP LIGHTING (POWER 90 MIN.)NEW
EXIT
EXIT
ARIETYV
EXISTING
PIPE MATERIALS
SERVICES LOCATION MATERIAL JOINING
METHOD REMARKS
DOMESTIC
COLD & HOT
WATER
UNDERGROUND RIGID COPPER( TYPE K)BRAZED NOT TO EXCEED 20 OF I PERCENT JOINT FITTINGS. SHOULD STREET
PRESSURE EXCEED 80 PSI, A PRESSURE REDUCING VALVE ASSEMBLY
SHALL BE INSTALLED. NO JOINTS SHALL BE ALLOWED UNDER
BUILDING SLAB. GATE VALVES SHALL BE BRONZE WITH ENDS TO
SUITE PIPE, NONRISING STEM FOR 150 PSI WORKING PRESSURE.
ABOVE
UNDERGROUND RIGID COPPER( TYPE L)SOLDERED
SANITARY
WASTE SEWER
UNDERGROUND CAST IRON SOIL PIPE & FITTINGS
OR OTHER APPROVED MATERIAL HUBLESS
ABOVE
GROUND
CAST IRON SOIL PIPE & FITTINGS
OR OTHER APPROVED MATERIAL HUBLESS
SANITARY
WASTE VENT
ABOVE
GROUND
CAST IRON SOIL PIPE & FITTINGS
OR OTHER APPROVED MATERIAL HUBLESS
LOW PRESSURE
GAS
UNDERGROUND SCHEDULE 40 BLACK STEEL WELDED PROVEIDE APPROVED GAS PRESSUSRE REGULATORS. NATURAL GAS
RIGHT
AND LEFT HAND NIPPLES AND COUPLINGS SHALL BE NEW BLACK
IRON, UNIONS SHALL NOT BE USED EXCEPT AT UNITS AND VAVLES.
ABOVE
UNDERGROUND SCHEDULE 40 BLACK STEEL WELDED
ABS PIPE MAY BE USED WHEN FIRST APPROVED BY THE
ADMINISTRATIVE AUTHORITY
ABS PIPE MAY BE USED WHEN FIRST APPROVED BY THE
ADMINISTRATIVE AUTHORITY
ABS PIPE MAY BE USED WHEN FIRST APPROVED BY THE
ADMINISTRATIVE AUTHORITY
PLUMBING ABBREVIATIONSPLUMBING LEGENDMEP COMPONENT ANCHORAGE NOTE
PIPING SYSTEM BRACING NOTE
GENERAL NOTES
DOMESTIC WATER PIPING SIZING DOMESTIC WATER CALCULATION
FIXTURE CONNECTION SCHEDULE (BRANCH SIZES)
MISC. EQUIPMENT SCHEDULE
REVISIONS
J
S
E
N
G
I
N
E
E
R
I
N
G
,
I
N
C
.
STAMP
P1
61
7
S
.
1
S
T
.
A
V
E
.
,
A
R
C
A
D
I
A
,
C
A
.
9
1
0
0
7
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
-
SE
C
R
E
T
A
R
T
S
T
U
D
I
O
LEGEND
CHAIR
NO
DESCRIPTION
QUA
2
2
2 TOOLS CASE
EXIT
EXIT
W
H
EXIT
EXIT
W
H
EXIT
EXIT
FLOOR PLAN (HOT & COLD)
1/4"=1'-0"
FLOOR PLAN (WASTE & VENT)
1/4"=1'-0"
FLOOR PLAN (GAS)
1/4"=1'-0"
REVISIONS
J
S
E
N
G
I
N
E
E
R
I
N
G
,
I
N
C
.
STAMP
P2
61
7
S
.
1
S
T
.
A
V
E
.
,
A
R
C
A
D
I
A
,
C
A
.
9
1
0
0
7
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
-
SE
C
R
E
T
A
R
T
S
T
U
D
I
O